WorldWideScience

Sample records for multislice ct imaging

  1. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  2. Multislice CT imaging of anomalous coronary arteries

    International Nuclear Information System (INIS)

    Shi Heshui; Aschoff, Andrik J.; Brambs, Hans-Juergen; Hoffmann, Martin H.K.

    2004-01-01

    The purpose of the present study was to evaluate the role of 16 multislice computed tomography (MSCT) to identify the origin of anomalous coronary arteries and to confirm their anatomic course in relation to the great vessels. Accuracy of coronary artery disease (CAD) detection was a secondary aim and was tested with conventional angiograms (CA) serving as standard of reference. Two hundred and forty-two consecutive patients referred for noninvasive coronary CT imaging were reviewed for the study. Sixteen patients (6.6%) with anomalous coronary arteries were detected and included as the study group. MSCT and CA images were analyzed in a blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Accuracy ratios to detect CAD with MSCT in all vessels were calculated. Coronary anomalies for all 16 patients were correctly displayed on MSCT. CA alone achieved correct identification of the abnormality in only 53% (P=0.016). Sensitivity and specificity of MSCT to detect significantly stenosed vessels was 90 and 92%. 16-MSCT is accurate to delineate abnormally branching coronary arteries and allows sufficiently accurate detection of obstructive coronary artery disease in distal branches. It should therefore be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (orig.)

  3. Three-dimensional multislice CT imaging of otitis media

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro; Wada, Akihiro; Ando, Ichiro

    2002-01-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  4. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  5. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  6. Incorporating multislice imaging into x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H., E-mail: holly.johnston@utsw.edu [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2 (Canada); Hilts, M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Medical Physics, BC Cancer Agency, Vancouver Island Centre, Victoria, British Columbia V8R 6V5 (Canada); Jirasek, A. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Department of Physics, University of British Columbia—Okanagan Campus, Kelowna, British Columbia V1V 1V7 (Canada)

    2015-04-15

    Purpose: To evaluate multislice computed tomography (CT) scanning for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD) and to establish a baseline assessment of image noise and uniformity in an unirradiated gel dosimeter. Methods: A 16-slice CT scanner was used to acquire images through a 1 L cylinder filled with water. Additional images were collected using a single slice machine. The variability in CT number (N{sub CT}) associated with the anode heel effect was evaluated and used to define a new slice-by-slice background subtraction artifact removal technique for CT PGD. Image quality was assessed for the multislice system by evaluating image noise and uniformity. The agreement in N{sub CT} for slices acquired simultaneously using the multislice detector array was also examined. Further study was performed to assess the effects of increasing x-ray tube load on the constancy of measured N{sub CT} and overall scan time. In all cases, results were compared to the single slice machine. Finally, images were collected throughout the volume of an unirradiated gel dosimeter to quantify image noise and uniformity before radiation is delivered. Results: Slice-by-slice background subtraction effectively removes the variability in N{sub CT} observed across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image noise was higher for the multislice system compared to the single slice scanner, but overall image quality was comparable between the two systems. Further study showed N{sub CT} was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thicknesses examined. In addition, the multislice system was found to eliminate variations in N{sub CT} due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to

  7. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  8. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    International Nuclear Information System (INIS)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi

    2003-01-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  9. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi [Osaka Medical Coll., Takatsuki (Japan)] (and others)

    2003-03-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  10. Imaging anatomy of the infraorbital ethmoid cells on multislice CT

    International Nuclear Information System (INIS)

    Pan Zhenyu; Qian Xiaojun; Gu Hua; Zhai Renyou

    2008-01-01

    Objective: To study the anatomic characteristics of the infraorbital ethmoid cells on multislice CT (MSCT) and explore the relationship between the infraobital ethmoid cells and mucosal swelling of sinuses. Methods: Two hundred sixty patients (520 sides) of consecutive axial scans by GE Hispeed VCT and the multiplanar reformation (MPR), virtual endoscopy(VE) reconstruction images by GE AW 4.2 workstation were reviewed retrospectively. The following CT features were assessed: (1) the anatomic characteristics of the infraobital ethmoid cells, including the frequency of identification, origin, classification, (2) presence of mucosal swelling of sinuses, (3) the maximal transversal diameter of the infraobital ethmoid cells in ostium of maxillary sinus (perpendicular to the uncinate process), and the diameter of the ostium of maxillary sinus, (4) presence of infraobital ethmoid cells inflammatory findings and a contact between the mucosal surface of the ostium of maxillary sinus. The results were analyzed by using Chi-square test and logistic regression analysis with the statistical software SPSS 11.5. Results: (1) Unilateral infraobital ethmoid cells were found in 68 patients (26.1%), and bilateral infraobital ethmoid cells were found in 81 patients (31.2%). Infraobital ethmoid cells were found in 230 sides on left side (120 sides) and right side(110 sides). (2)Infraobital ethmoid cells originated from the anterior ethmoid cells in 124 sides (53.9%) and from posterior ethmoidal cells in 62 sides (27%), originated from both the anterior ethmoidal cells and the posterior ethmoidal cells in 44 sides( 19. 1% ). (3)The classification of the infraobital ethmoid cells included three types. Infraobital ethmoid cells with different origination differed significantly in their types (X 2 =193.433, P 2 =1.824, P>0.05). The maximal transversal diameter of the infraobital ethmoid cells in ostium of maxillary sinus did not differ significantly between the cases with or without

  11. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  12. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    Science.gov (United States)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  13. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  14. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Doerfler, Arnd; Deuerling-Zheng, Yu; Boese, Jan; Zellerhoff, Michael; Schwab, Stefan

    2011-01-01

    We tested the hypothesis that Flat Detector computed tomography (FD-CT) with intravenous contrast medium would allow the calculation of whole brain cerebral blood volume (CBV) mapping (FD-CBV) and would correlate with multislice Perfusion CT (PCT). Twenty five patients were investigated with FD-CBV and PCT. Correlation of the CBV maps of both techniques was carried out with measurements from six anatomical regions from both sides of the brain. Mean values of each region and the correlation coefficient were calculated. Bland-Altman analysis was performed to compare the two different imaging techniques. The image and data quality of both PCT and FD-CBV were suitable for evaluation in all patients. The mean CBV values of FD-CBV and PCT showed only minimal differences with overlapping standard deviation. The correlation coefficient was 0.79 (p < 0.01). Bland-Altman analysis showed a mean difference of -0.077 ± 0.48 ml/100 g between FD-CBV and PCT CBV measurements, indicating that FD-CBV values were only slightly lower than those of PCT. CBV mapping with intravenous contrast medium using Flat Detector CT compared favourably with multislice PCT. The ability to assess cerebral perfusion within the angiographic suite may improve the management of ischaemic stroke and evaluation of the efficacy of dedicated therapies. (orig.)

  15. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  16. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  17. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  18. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  19. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  20. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  1. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT

    International Nuclear Information System (INIS)

    Vembar, M.; Garcia, M.J.; Heuscher, D.J.; Haberl, R.; Matthews, D.; Boehme, G.E.; Greenberg, N.L.

    2003-01-01

    In this investigation, we describe a quantitative technique to measure coronary motion, which can be correlated with cardiac image quality using multislice computed tomography (MSCT) scanners. MSCT scanners, with subsecond scanning, thin-slice imaging (sub-millimeter) and volume scanning capabilities have paved the way for new clinical applications like noninvasive cardiac imaging. ECG-gated spiral CT using MSCT scanners has made it possible to scan the entire heart in a single breath-hold. The continuous data acquisition makes it possible for multiple phases to be reconstructed from a cardiac cycle. We measure the position and three-dimensional velocities of well-known landmarks along the proximal, mid, and distal regions of the major coronary arteries [left main (LM), left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX)] during the cardiac cycle. A dynamic model (called the 'delay algorithm') is described which enables us to capture the same physiological phase or 'state' of the anatomy during the cardiac cycle as the instantaneous heart rate varies during the spiral scan. The coronary arteries are reconstructed from data obtained during different physiological cardiac phases and we correlate image quality of different parts of the coronary anatomy with phases at which minimum velocities occur. The motion characteristics varied depending on the artery, with the highest motion being observed for RCA. The phases with the lowest mean velocities provided the best visualization. Though more than one phase of relative minimum velocity was observed for each artery, the most consistent image quality was observed during mid-diastole ('diastasis') of the cardiac cycle and was judged to be superior to other reconstructed phases in 92% of the cases. In the process, we also investigated correlation between cardiac arterial states and other measures of motion, such as the left ventricular volume during a cardiac cycle, which earlier has been

  2. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  3. Assessment of hemodynamics in a rat model of liver cirrhosis with precancerous lesions using multislice spiral CT perfusion imaging.

    Science.gov (United States)

    Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng

    2013-01-01

    To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.

  4. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  5. SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

    International Nuclear Information System (INIS)

    Nam, H; Guo, M; Lee, K; Li, R; Xing, L; Gao, H

    2014-01-01

    Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed

  6. The effect of pitch in multislice spiral/helical CT

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    2000-01-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  7. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  8. Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukushima, Hiromichi; Takada, Akira; Mori, Yoshimi; Suzuki, Kojiro; Sawaki, Akiko; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo; Itoh, Shigeki; Ikeda, Mitsuru

    2006-01-01

    The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone. (orig.)

  9. Development of an automated extraction method for liver tumors in three dimensional multiphase multislice CT images

    International Nuclear Information System (INIS)

    Nakagawa, Junya; Shimizu, Akinobu; Kobatake, Hidefumi

    2004-01-01

    This paper proposes a tumor detection method using four phase three dimensional (3D) CT images of livers, i.e. non-contrast, early, portal, and late phase images. The method extracts liver regions from the four phase images and enhances tumors in the livers using a 3D adaptive convergence index filter. Then it detects local maximum points and extracts tumor candidates by a region growing method. Subsequently several features of the candidates are measured and each candidate is classified into true tumor or normal tissue based on Mahalanobis distances. Above processes except liver region extraction are applied to four phase images, independently and four resultant images are integrated into one. We applied the proposed method to 3D abdominal CT images of ten patients obtained with multi-detector row CT scanner and confirmed that tumor detection rate was 100% without false positives, which was quite promising results. (author)

  10. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  11. Assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images

    Directory of Open Access Journals (Sweden)

    Habibeh Farazdaghi

    2017-02-01

    Full Text Available Background and Aims: Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. The aim of this study was the assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images. Materials and Methods: For volumetric analysis, axial paranasal sinus CT scan with 3-mm slice thickness was used. For this study, 80 images (40 women and 40 men older than 18 years were selected. For the assessment of sphenoid sinus volume, Digimizer software was used. The volume of sphenoid sinus was calculated using the following equation: v=∑ (area of each slice × thickness of each slice. Statistical analysis was performed by independent T-test. Results: The mean volume of sphenoid sinus was significantly greater in male gender (P=0.01.The assessed Cut off point was 9/35 cm3, showing that 63.4% of volume assessments greater than cut off point was supposed to be male and 64.1% of volumetry lesser than cut off point were female. Conclusion: According to the area under Roc curve (1.65%, sphenoid sinus volume is not an appropriate factor for differentiation of male and female from each other, which means the predictability of cut off point (9/35 cm3 is 65/1% close to reality.

  12. Evaluation of obstructive airway lesions in complex congenital heart disease using composite volume-rendered images from multislice CT

    International Nuclear Information System (INIS)

    Choo, Ki Seok; Kim, Chang Won; Lee, Tae Hong; Kim, Suk; Kim, Kun Il; Lee, Hyoung Doo; Ban, Ji Eun; Sung, Si Chan; Chang, Yun Hee

    2006-01-01

    Multislice CT (MSCT) allows high-quality volume-rendered (VR) and composite volume-rendered images. To investigate the clinical usefulness of composite VR images in the evaluation of the relationship between cardiovascular structures and the airway in children with complex congenital heart disease (CHD). Four- or 16-slice MSCT scanning was performed consecutively in 77 children (mean age 6.4 months) with CHD and respiratory symptoms, a chest radiographic abnormality, or abnormal course of the pulmonary artery on ECHO. MSCT scanning was performed during breathing or after sedation. Contrast medium (2 ml/kg) was administered through a pedal venous route or arm vein in all patients. The VR technique was used to reconstruct the cardiovascular structures and airway, and then both VR images were composed using the commercial software (VoxelPlus 2 ; Daejeon, Korea). Stenoses were seen in the trachea in 1 patient and in the bronchi in 14 patients (19%). Other patients with complex CHD did not have significant airway stenoses. Composite VR images with MSCT can provide more exact airway images in relationship to the surrounding cardiovascular structures and thus help in optimizing management strategies in treating CHD. (orig.)

  13. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  14. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  15. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    Energy Technology Data Exchange (ETDEWEB)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry [Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Department of Radiology and Medical Imaging, Brussels (Belgium); Robert, Annie [Public Health School, Universite Catholique de Louvain, Department of Epidemiologics and Medical Statistics, Brussels (Belgium); Vlassenbroek, Alain [CT Clinical Science, Philips Medical Systems, Cleveland, OH (United States)

    2007-04-15

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  16. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    International Nuclear Information System (INIS)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry; Robert, Annie; Vlassenbroek, Alain

    2007-01-01

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  17. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Honda, Eiichi; Tetsumura, Akemi; Kurabayashi, Tohru

    2011-01-01

    Purpose: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases. Materials and methods: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom. Results: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64x) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64. Conclusions: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases.

  18. Multislice ct in gut related pathologies

    International Nuclear Information System (INIS)

    Nadeem, A.; Shaukat, A.; Ahmad, M.W.; Amin, Y.

    2007-01-01

    The objective of this study is to evaluate the effectiveness of Multislice CT in Gut related pathologies. 50 consecutive patients, referred from surgical and medical departments, with gut pathology suspicion were scanned in this respect on Toshiba MSCT 4 slice Aquilion. Patients were. 100 ml iodinated non ionic IV contrast was given. Preferably water was used as oral contrast and oral iodinated contrast was used only in selective cases. As a result, 33 patients showed positive response and 17 were normal; 23 were females and 10 were males. We found following pathologies Acute Appendicitis 10, Diverticulitis 02, Inflammatory Bowel Disease 03, Small Bowel Obstruction 04, Malignant Gut masses 08, Omental Implants 05, Perforation (Duodenal) 01. It is thus concluded that MDCT has a definite role in gut pathologies especially when the ultrasound is negative. (author)

  19. Multislice CT imaging of ruptured left sinus of Valsalva aneurysm with fistulous track between left sinus and right atrium.

    Science.gov (United States)

    Pampapati, Praveenkumar; Rao, Hejmadi Tati Gururaj; Radhesh, Srinivasan; Anand, Hejjaji Krishnamurthy; Praveen, Lokkur Srinivasamurthy

    2011-01-01

    Sinus of valsalva aneurysm is a rare condition arising from any of the three aortic sinuses. Among them, an aneurysm arising from the left coronary sinus is the rarest. Most of these cases were earlier diagnosed using echocardiography and conventional angiography. But with the availability of advanced imaging modalities like 64 slice cardiac CT and MR modalities, this condition can be accurately assessed noninvasively. We report a case of ruptured aneurysm originating from the left coronary sinus with a long windsock type of fistulous track between the aneurysm and right atrium evaluated by 64 slice cardiac CT imaging. This was later confirmed perioperatively.

  20. Detection and classification of focal liver lesions in patients with colorectal cancer: Retrospective comparison of diffusion-weighted MR imaging and multi-slice CT

    International Nuclear Information System (INIS)

    Eiber, Matthias; Fingerle, Alexander A.; Brügel, Melanie; Gaa, Jochen; Rummeny, Ernst J.; Holzapfel, Konstantin

    2012-01-01

    Objectives: To compare the diagnostic performance of diffusion-weighted MR imaging (DWI) with multi-slice CT (MS-CT) in the detection and classification of focal liver lesions in patients with colorectal cancer. Methods: In a retrospective study 68 patients who underwent DWI at 1.5 T (b-values of 50, 300 and 600 s/mm 2 ) and contrast-enhanced MS-CT were analysed by two radiologists blinded to the clinical results. Imaging results were correlated with intraoperative surgical and ultrasound findings (n = 24), imaging follow-up or PET (n = 44). Sensitivity of DWI and MS-CT in detection of focal liver lesions was compared on a per-lesion and a per-segment basis. Receiver operator-characteristic (ROC) curves to determine the diagnostic performance and the sensitivities of correctly identifying liver metastases on a segmental base were calculated. Results: For lesion detection, DWI was significantly superior to MS-CT both on a per-lesion (difference in sensitivities for reader 1 and 2 22.65% and 19.06%, p < 0.0001) and a per-segment basis (16.86% and 11.76%, p < 0.0001). Especially lesions smaller than 10 mm were better detected with DWI compared to MS-CT (difference 41.10% and 29.45%, p < 0.0001). ROC-analysis showed superiority for lesions classification (p < 0.0001) of DWI (AUC: 0.949 and 0.951) as compared to MS-CT (AUC: 0.879 and 0.892, p < 0.0001 and p = 0.005). DWI was able to filter out metastatic segments with a higher sensitivity (88.2 and 86.5%) compared to MS-CT (68.0 and 67.4%, p < 0.0001 and p = 0.005, respectively). Conclusion: Compared to MS-CT DWI is both more sensitive in the detection of liver lesions and more accurate in determining the extent of metastatic disease in patients with colorectal cancer and therefore might help to optimize therapeutic management in those patients.

  1. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  2. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  3. Multislice helical CT in the diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yang Li; Zhao Shaohong; Nie Yongkang; Zhao Hong; Fang Jie; Cai Zulong; Yang Zhou; Ying Yifeng

    2005-01-01

    Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, respectively ( P < 0105 ) 1 The tumor involving the bile duct was enhanced most remarkablely on 25 s phase, and the bile duct wall thickening, bile duct narrowing or occlusion were demonstrated as the p rimary findings of hilar cholangiocarcinoma1 The intraductal sp read of tumor could be demonstrated as small nodules on the bile duct wall p roximal or distal to the tumor1 Conclusion. The tumor involving the bile duct can be enhanced most remarkablely on 25 s phase after contrast injection1 Multislice helical CT, especially 3D reconstructed images, can be used to detect the direct findings of hilar cholangiocarcinomas and the extension of tumor involving the bile duct. (authors)

  4. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    International Nuclear Information System (INIS)

    Abe, T.; Izumiyama, H.; Fujisawa, I.

    2002-01-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders

  5. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Abe, T.; Izumiyama, H. [Showa Univ. School of Medicine, Tokyo (Japan). Dept. of Neurosurgery; Fujisawa, I. [Kishiwada City Hospital, Kishiwada (Japan). Dept. of Radiology

    2002-11-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders.

  6. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Jianjun, Li; Renyou, Zhai; Dongpo, Zhang; Qiang, Huang; Dingke, Dai; Ping, Yu; Na, Bao [Department of Radiology, Beijing Chaoyang Hospital, Capital Medical Univ., Beijing (China)

    2008-10-15

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4{+-}15.7)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (293.7{+-} 7.9) ml{center_dot}min{sup -1{center_dot}}100 g {sup -1}, (379.4{+-}14.5)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (382.5{+-}16.6)ml{center_dot}min{sup -1{center_dot}}. 100 g{sup -1}] and [(3.1{+-}0.2)s, (2.6{+-}0.2)s, (2.2{+-}0.1)s, (1.9{+-}0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P<0.01) between groups (A and B, A and C, A and D, B and C, B and D) except between group C and D (the P value >0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2{+-} 19.2)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1} and (259

  7. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Li Jianjun; Zhai Renyou; Zhang Dongpo; Huang Qiang; Dai Dingke; Yu Ping; Bao Na

    2008-01-01

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4±15.7)ml·min -1 ·100 g -1 , (293.7± 7.9) ml·min -1 ·100 g -1 , (379.4±14.5)ml·min -1 ·100 g -1 , (382.5±16.6)ml·min -1 ·. 100 g -1 ] and [(3.1±0.2)s, (2.6±0.2)s, (2.2±0.1)s, (1.9±0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P 0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2± 19.2)ml·min -1 ·100 g -1 and (259.4±15.7) ml·min -1 ·100 g -1 in group A, (393.2±16.1) ml· min -1 ·100 g -1 and (293.7±7.9) ml·min -1 ·100 g -1 in group B] and MTF [(1.8±0.1)s and (3.1±0.2) s in group A, (1.8±0.2) s and (2.6±0.2) s in group B] were statistically different (P 0.05) between groups

  8. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  9. Optimization of pediatric examinations in a multislice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Ombada, T H. A. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI{sub v}ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI{sub v}ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  10. The value of multi-slice spiral CT liver perfusion imaging to evaluate the chronic hepatic fibrosis and cirrhosis

    International Nuclear Information System (INIS)

    Long Liling; Huang Zhongkui; Ding Ke; Liao Jinyuan; Jiang Jianning

    2012-01-01

    Objective: To investigate the value of the MSCT liver perfusion imaging parameters in the evaluation of the chronic hepatic fibrosis and cirrhosis. Methods: Liver CT perfusion (CTP) was performed in 107 participants,including 31 patients with mild hepatic fibrosis (S1, S2), 34 patients with severe hepatic fibrosis (S3, S4) and early stage of hepatic cirrhosis which conformed by liver pathologic biopsy, 42 patients with hepatic cirrhosis who had typical clinical and image signs, and 30 healthy subjects as control group. The data of CTP (HAP, PVP, LTP, HPI and TTP) at different stages were obtained with Body perfect CT-syngo CT2007A and control study with histopathologic stage. Compared the study index by the one-way ANOVA analysis. Used Spearman rank correlation to analysis the relationship between liver perfusion imaging parameters and the degrees of the chronic hepatic fibrosis. Used Logistic regression to analysis the maximum regression coefficient among the liver perfusion imaging parameters, which affected the histopathologic stage mostly. Results: In the subgroups of the chronic hepatic fibrosis S1, S2, S3, S4 to the hepatic cirrhosis,HAP values was (28.9 ±8.6), (24.6 ±2.4), (29.2 ±2.3) and (38.9 ± 7.0) ml · 100 ml -1 · min -1 , respectively. HAP decreased firstly,then increased. Statistic analysis showed the difference of HAP between later-stage cirrhosis and other groups (F=40.26, P<0.01). PVP values of above subgroups was (111.3 ± 18.1), (92.9 ±5.3), (73.0 ±9.0) and (54.1 ± 13.8) ml · 100 ml -1 ·min -1 , respectively. TLP values of above subgroups was (140.2 ± 25.9), (117.1 ± 4.5), (102.3 ± 8.7)and (93.0 ± 11.8) ml · 100 ml -1 ·min -1 , respectively. The difference of PVP, TLP among each subgroup was significant (F=136.79, 67.40, respectively, P<0.01). HPI values of above subgroups was (20.4 ± 2.6)%, (21.0 ±2.1)%, (28.5 ±3.1)% and (42.6± 11.1)%, respectively. TTP values of above subgroups was (123.7±22.2), (137.1 ±27.1), (145.0 ±28

  11. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee

    2009-01-01

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  12. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea); Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun [University of Ulsan College of Medicine, Department of Pediatric Cardiac Surgery, Asan Medical Center, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [University of Ulsan College of Medicine, Department of Pediatric Cardiology, Asan Medical Center, Seoul (Korea)

    2009-03-15

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  13. Can 16-detector multislice CT exclude skeletal lesions during tumour staging? Implications for the cancer patient

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Beadsmoore, Clare J.; Courtney, Helen M.; Harish, Srinivasan; Bearcroft, Philip W.P.; Dixon, Adrian K.; Cheow, Heok K.; Balan, Kottekkattu K.; Kaptoge, Stephen; Win, Thida

    2006-01-01

    Current imaging guidelines recommend that many cancer patients undergo soft-tissue staging by computed tomography (CT) whilst the bones are imaged by skeletal scintigraphy (bone scan). New CT technology has now made it feasible, for the first time, to perform a detailed whole-body skeletal CT. This advancement could save patients from having to undergo duplicate investigations. Forty-three patients with known malignancy were investigated for bone metastasis using skeletal scintigraphy and 16-detector multislice CT. Both studies were performed within six weeks of each other. Whole-body images were taken 4 h after injection of 500 Mbq 99m Tc-MDP using a gamma camera. CT was performed on a 16-detector multislice CT machine from the vertex to the knee. The examinations were reported independently and discordant results were compared at follow-up. Statistical equivalence between the two techniques was tested using the Newcombe-Wilson method within the pre-specified equivalence limits of ±20%. Scintigraphy detected bone metastases in 14/43 and CT in 13/43 patients. There were seven discordances; four cases were positive on scintigraphy, but negative on CT; three cases were positive on CT and negative on scintigraphy. There was equivalence between scintigraphy and CT in detecting bone metastases within ±19% equivalence limits. Patients who have undergone full whole-body staging on 16-detector CT may not need additional skeletal scintigraphy. This should shorten the cancer patient's diagnostic pathway. (orig.)

  14. Rapid fusion of 2D X-ray fluoroscopy with 3D multislice CT for image-guided electrophysiology procedures

    Science.gov (United States)

    Zagorchev, Lyubomir; Manzke, Robert; Cury, Ricardo; Reddy, Vivek Y.; Chan, Raymond C.

    2007-03-01

    Interventional cardiac electrophysiology (EP) procedures are typically performed under X-ray fluoroscopy for visualizing catheters and EP devices relative to other highly-attenuating structures such as the thoracic spine and ribs. These projections do not however contain information about soft-tissue anatomy and there is a recognized need for fusion of conventional fluoroscopy with pre-operatively acquired cardiac multislice computed tomography (MSCT) volumes. Rapid 2D-3D integration in this application would allow for real-time visualization of all catheters present within the thorax in relation to the cardiovascular anatomy visible in MSCT. We present a method for rapid fusion of 2D X-ray fluoroscopy with 3DMSCT that can facilitate EP mapping and interventional procedures by reducing the need for intra-operative contrast injections to visualize heart chambers and specialized systems to track catheters within the cardiovascular anatomy. We use hardware-accelerated ray-casting to compute digitally reconstructed radiographs (DRRs) from the MSCT volume and iteratively optimize the rigid-body pose of the volumetric data to maximize the similarity between the MSCT-derived DRR and the intra-operative X-ray projection data.

  15. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  16. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  17. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  18. Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Ikeda, Mitsuru; Suzuki, Koujiro; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo

    2005-01-01

    The purpose of this study was to evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT). In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase. Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively. Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation. (author)

  19. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  20. Low-dose multislice CT in febrile neutropenic patients

    International Nuclear Information System (INIS)

    Wendel, F.; Jenett, M.; Hahn, D.; Sandstede, J.; Geib, A.

    2005-01-01

    Purpose: to define the value of low-dose multislice CT in a clinical setting for early detection of pneumonia in neutropenic patients with fever of unknown origin. Materials and methods: thirty-five neutropenic patients suffering from fever of unknown origin with normal chest X-ray underwent unenhanced low-dose CT of the chest (120 kV, 10 eff. mAs, collimation 4 x 1 mm) using a multislice CT scanner. Axial und frontal slices with a thickness of 5 mm were calculated. If no pneumonia was found, standard antibiotics were given and a repeated examination was performed if fever continued. In case of pneumonia, antimycotic therapy was added and a follow-up CT was performed within one week. Regression or progression of pneumonia at follow-up served as evidence of pneumonia; lowering of fever within 48 h or inconspicuous follow-up CT was regarded as absence of pneumonia. Results: ten of 35 patients had pneumonic infiltration, which decreased or increased on follow-up CT in 3 and 6 patients, respectively. One patient revealed leucemic infiltration by bronchoalveolar lavage. Twenty-five of 35 patients had no evidence of pneumonia. Twenty of these patients were free of fever within 48 h under antibiotics; one patient died due to his basic illness. Out of 4 patients with persisting fever, 3 patients had no pneumonia on repeated examination; one patient showed disseminated micronodular infiltration. Frontal reconstructions helped to differentiate infiltration from atelectasis in 4 patients. Sensitivity and specificity for the detection of pneumonia at the first examination were 90% and 96%, negative predictive value was 96%. Conclusion: low-dose multislice CT should be performed in neutropenic patients having a fever of unknown origin and normal chest X-ray. (orig.)

  1. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  2. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  3. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  4. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  5. Diagnosis of pelvic wall tumor on multislice CT

    International Nuclear Information System (INIS)

    Zhang Keyun; Deng Lequn; Lei Hongwei

    2011-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) in diagnosing pelvic wall tumors. Methods: MSCT of 21 cases of pelvic wall tumors including metastasis (10), neurogenic tumor (5), chondrosarcoma (2), chordoma (1), aneurysmal bone cyst (1), giant cell tumor (1), and osteochondroma (1) was retrospectively analyzed. Results: CT appearances of pelvic wall tumors include bony destruction and soft tissue masses. Common features were bone destruction in metastasis, expansion of the neuroforamen in neurogenic tumor, pleomorphic calcification in chondrosarcoma, lower sacral vertebral location of chordoma, iliac crest bone destruction in giant cell tumor, cauliflower-like nodules in osteochondroma. Conclusion: MSCT with three-dimensional volume rendering demonstrates well the tumor shape, size, extent, internal structure and relationship with the surrounding organs to aid diagnosis of pelvic wall tumors. (authors)

  6. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  7. Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of Coronary Angiography

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Mollet, Nico R.; Runza, Giuseppe

    2005-01-01

    Purpose. To assess the variability in attenuation of coronary plaques with multislice CT angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. Materials and methods. MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1180). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f medium, and B60f-sharp). Each scan was scored for the presence of plaques. Once a plaque was detected, the operator performed attenuation measurements (HU) in coronary lumen, oil, calcified and soft plaque tissue using the same settings in all datasets. The results were compared with T-test and correlated with Pearson's test. Results. Overall, 464 measurements were performed. Significant differences (p [it

  8. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F. [Department of Radiology, Azienda Ospedaliera ' ' SS Antonio e Biagio e C. Arrigo' ' , Alessandria (Italy)

    2002-05-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  9. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    International Nuclear Information System (INIS)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F.

    2002-01-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  10. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  11. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  12. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  13. Congenital intrahepatic arterioportal and portosystemic venous fistulae with jejunal arteriovenous malformation depicted on multislice spiral CT

    International Nuclear Information System (INIS)

    Chae, Eun Jin; Goo, Hyun Woo; Yoon, Chong Hyun; Kim, Seong-Chul

    2004-01-01

    We report a symptomatic infant with very rare congenital arterioportal and portosystemic venous fistulae in the liver. Multislice CT after partial transcatheter embolisation revealed not only the complicated vascular architecture of the lesion, but also an incidental jejunal arteriovenous malformation which explained the patient's melena. The patient underwent ligation of the hepatic artery and resection of the jejunal arteriovenous malformation. Postoperative multislice CT clearly demonstrated the success of the treatment. (orig.)

  14. Measurements of angles of the normal auditory ossicles relative to the reference plane and image reconstruction technique for obtaining optimal sections of the ossicles in high-resolution multiplanar reconstruction using a multislice CT scanner

    International Nuclear Information System (INIS)

    Fujii, Naoko; Katada, Kazuhiro; Yoshioka, Satoshi; Takeuchi, Kenji; Takasu, Akihiko; Naito, Kensei

    2005-01-01

    Using high-resolution isotropic volume data obtained by 0.5 mm, 4-row multislice CT, cross-sectional observation of the auditory ossicles is possible from any desired direction without difficulty in high-resolution multiplanar reconstruction (HR-MPR) images, also distortion-free three-dimensional images of the ossicles are generated in three-dimensional CT (3D-CT) images. We measured angles of fifty normal ossicles relative to the reference plane, which has been defined as a plane through the bilateral infraorbital margins to the middle portion of the external auditory canal. Based on the results of angle measurement, four optimal sections of the ossicles for efficient viewing to the ossicular chain were identified. To understand the position of the angle measurement and the four sections, the ossicles and the reference plane were reconstructed in the 3D-CT images. As the result of observation of the ossicles and the reference plane, the malleus was parallel to the incudal long process and perpendicular to the reference plane. As the results of angle measurement, the mean angle of the tympanic portion of the facial nerve relative to the reference plane in the sagittal plane was found to be 17 deg, and the mean angle of the stapedial crura relative to the reference plane in the sagittal plane was found to be 6 deg. The mean angle of the stapes relative to the reference plane in the coronal plane was 44 deg, and the mean angle of the incudal long process relative to the stapes in the coronal plane was 89 deg. In 80% of ears, the stapes extended straight from the incudal long process. Image reconstruction technique for viewing four sections of the ossicles was investigated. Firstly, the image of the malleal head and the incudal short process was identified in the axial plane. Secondly, an image of the malleus along the malleal manubrium was reconstructed in the coronal plane. Thirdly, the image of the incudal long process was seen immediately behind the malletis image

  15. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  16. Multislice CT for preoperative diagnosis of pancreatic cancer

    International Nuclear Information System (INIS)

    Horiguchi, Akihiko; Ishihara, Shin; Ito, Masahiro

    2007-01-01

    We investigated the ability of multislice (MS) CT to visualize and diagnose the progression of pancreatic cancer. With regard to local progression, good diagnosis was possible for detecting the invasion of the intrapancreatic bile duct, duodenum, portal vein, arteries and other organs, and liver metastasis. Sensitivity was high but specificity was not good for detecting the invasion of the anterior and posterior pancreatic tissue. This is thought to be because of the positive diagnosis with pancreatitis that accompanies cancer. Pancreatic plexus invasion was also thought to be a cause of the lipid elevation of the nerve plexus and decreased sensitivity accompanying pancreatitis. Identification of cancer invasion and tumor periphery changes based on concomitant pancreatitis also depends on the amount of fibrous stroma, but this will require further investigation. Factors other than the size of lymph node metastases also need to be investigated. MS-CT can provide detailed volume data in a short time and making it an essential test in diagnosing the stage of pancreatic cancer. (author)

  17. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  18. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT

    NARCIS (Netherlands)

    Parsa, A.; Ibrahim, N.; Hassan, B.; van der Stelt, P.; Wismeijer, D.

    2015-01-01

    Objectives The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the

  19. Chronic thromboembolic pulmonary hypertension: diagnostic impact of multislice-CT and selective pulmonary-DSA

    International Nuclear Information System (INIS)

    Pitton, M.B.; Kemmerich, G.; Herber, S.; Schweden, F.; Thelen, M.; Mayer, E.

    2002-01-01

    Purpose: To evaluate the diagnostic impact of multislice-CT and selective pulmonary DSA in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: 994 vessel segments of 14 consecutive patients with CTEPH were investigated with multislice-CT (slice thickness 3 mm, collimation 2.5 mm, reconstruction intervall 2 mm) and selective pulmonary DSA posterior-anterior, 45 oblique, and lateral projection. Analysis was performed by 2 investigators independently for CT and DSA. Diagnostic criteria were occlusions and non-occlusive changes like webs and bands, irregularities of the vessel wall, diameter reduction and thromboembolic depositions at different levels from central pulmonary arteries to subsegmental arteries. Reference diagnosis was made by synopsis of CT and DSA by consensus. Results: Concerning patency CT and DSA showed concordant findings overall in 88.9%, 92.9% for segmental arteries and 85.4% for subsegmental arteries. Concerning any thromboembolic changes, multislice-CT was significantly inferior to selective DSA (concordance 67.0% overall, 70.4% for segments and 63.6% for subsegments). Non-occlusive changes of the vessels were significantly underdiagnosed by CT (concordance of CT versus DSA: 23.1%). Conclusion: Multislice-CT and selective pulmonary DSA are equivalent for diagnosis of vessel occlusions at the level of segmental and subsegmental arteries. However, for visualisation of the non-occlusive thromboembolic changes of the vessel wall selective pulmonary DSA is still superior compared to multislice-CT. Multislice-CT and selective pulmonary DSA are complementary tools for diagnosis and treatment planning of chronic thromboembolic pulmonary hypertension (CTEPH). (orig.) [de

  20. Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment.

    Science.gov (United States)

    Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C

    2014-01-01

    Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.

  1. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  2. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  3. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  4. Biliary complications after liver transplantation: diagnosis with multi-slice CT

    International Nuclear Information System (INIS)

    Zhu Kangshun; Meng Xiaochun; Xu Changmou; Shen Min; Qian Jiesheng; Pang Pengfei; Guan Shouhai; Jiang Zaibo; Shan Hong

    2009-01-01

    Objective: To evaluate multislice CT in the diagnosis of biliary complications after liver transplantation. Methods: Eighty-three consecutive patients who had undergone orthotopic liver transplantation (OLT) presented with clinical or biochemical signs of biliary complications and underwent contrast-enhancement CT examination. Three experienced radiologists, who were blinded to patient's clinical data, assessed CT images for the detection of biliary complications in consensus. Diagnostic confirmation of biliary complications was obtained with direct cholangiography in 69 patients, histologic study in 11 patients and hepaticojejunostomy in 3 patients. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for the detection of biliary complications were calculated. In addition, CT features of anastomotic biliary stricture (ABS) were compared with those of non-anastomotic biliary stricture (NABS) using χ 2 test. Results: A total of 62 biliary complications (74.7%) was eventually confirmed in the 83 patients, including ABS in 32 patients, NABS in 21 patients, biliary duct stones in 16 patients (of which 12 patients with biliary stricture) , anastomotic bile leakage in 5 patients, biloma in 4 patients with biliary stricture, and biliogenic abscess in 2 patients with biliary stricture. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for the detection of biliary stricture were 90.6%, 86.7%, 89.2%, 92.3% and 83.9%, respectively. Other biliary complications, including biliary duct stones (16 cases), anastomotic bile leak (5 cases), biloma (4 cases), and biliogenic abscess (2 cases), were correctly diagnosed by CT; there was no false-positive or false-negative result. The incidence of irregular dilatation of bile duct was 71.4% (15/21), which was significantly higher in NABS cases than in ABS of 25.0% (8/32, P<0.01); whereas the incidence of extrahepatic biliary dilatation

  5. Refined staging in hilar bronchial neoplasms with ECG-gated multislice-CT. Case report

    International Nuclear Information System (INIS)

    Ohlmann, S.; Daliri, A.; Froelich, J.J.; Nowak, R.; Michulla, R.

    2008-01-01

    Equivocal initial CT-based staging in 2 patients with hilar bronchial neoplasms was reassessed with retrospective ECG-gated Multislice-CT and optimized examination parameters prior to definition of treatment. An initially suspected irresectable T 4 tumor with mediastinal infiltration was downstaged to T 2 in one case, while tumor infiltration into the left atrium could be confirmed in the other case. In doubtful conditions, ECG-gated multislice CT with optimized examination parameters may be helpful for refined staging in patients with hilar bronchial neoplasma, thus possibly influencing treatment strategies. (orig.)

  6. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  7. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  8. The role of MR imaging with Half Fourier Acquired Single Shot Turbo Spin Echo sequence in the diagnosis of lung lesions in comparison with multislice CT

    International Nuclear Information System (INIS)

    Hekimoglu, B.; Gurgen, F.; Tatar, I.G.; Aydin, H.; Kizilgoz, V.; Keyik, B.

    2013-01-01

    Objective: To compare the diagnostic values of magnetic resonance imaging using Half Fourier Acquired Single Shot Turbo Spin Echo sequence and multidetector computed tomography in patients with pathologically examined pulmonary lesions. Methods: The retrospective, descriptive study was conducted at Radiology Department, Diskapi Research Hospital, Ankara, Turkey, and comprised records of patients with pathologically examined pulmonary lesions between May 2009 and March 2012. Patients were divided into three groups and examined by both multi dedector computed tomography and magnetic resonance imaging. During the imaging, patients were not administered any intravenous contrast medium. Electrocardiogram gating and breath holding were not performed in echo sequence. Pulmonary lesions were evaluated on the basis of their dimensions, numbers, differentiation from atelectasis and consolidation, invasion to the thoracic wall-mediastinal structures and presence of lymphadenopathies. Results: Sensitivity of all patients was 50% (p=0.214) and specificity of CT and MRI were 82.5% (p=0.134) for the detectability of submilimetric nodules . For differentiation of the mass from atelectasis and consolidation, the sensitivity of computed tomography was statistically more significant compared to magnetic resonance imaging (86.6%; p=0.035). For the invasion of the mass to the mediastinal structures and the thoracic wall, the sensitivity of magnetic resonance imaging was statistically more significant compared to tomography (86.6%; p=0.035). Conclusion: HASTE sequence can be used to determine the invasion of the pulmonary mass to the mediastinal structures and the thoracic wall since it is more sensitive than computed tomography. It can also be used to detect submilimetric nodules. It has equal sensitivity and specificity compared to computed tomography. But computed tomography is superior for the differentiation of the mass from atelectasis and consolidation. (author)

  9. Multi-slice CT (MSCT) in cardiac function imaging: threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI

    International Nuclear Information System (INIS)

    Ehrhard, K.; Oberholzer, K.; Gast, K.; Mildenberger, P.; Kreitner, K.F.; Thelen, M.

    2002-01-01

    Purpose: To assess MSCT of the heart to determining left ventricular ejection fraction (EF) based on threshold-value-supported 3D volume reconstructions compared to MRI. Methods: Cardiac MSCT was performed in 7 patients. Images were reconstructed during end-systolic and end-diastolic phases of the cardiac cycle and transformed to 3D volumes to determine end-systolic (ESV) and end-diastolic volume (EDV) by using different lower threshold values: besides fixed lower threshold values, identical for each image sequence, individual lower threshold values dependent on contrast enhancement of the left ventricle were applied. The latter represent the mean value calculated by combining the average CT-density of the myocardium and the contrast-enhanced blood in the left ventricle. The EF derived from ESV and EDV. Results: The best correlation with MR imaging was obtained for ESV and EDV by using the individual lower threshold values for the respective sequence. The correlation coefficient for ESV was 0.95 and for EDV it was 0.93. On average, the ESV was overestimated by 3.72 ml, while the ESD was underestimated by 2.85 ml. The respective standard deviation for the ESV was 14,87 ml, for the EDV it was 26.83 ml. On average, the EF was underestimated by 3.57% with a standard deviation of 9.43% and a correlation coefficient of 0.83 in comparison to MRI. Conclusion: The threshold-value-supported 3D volume reconstruction of the left ventricle represents a good method to determine the left ventricular function parameters. Due to the differences in the contrast enhancement, the use of an individual lower threshold value for every image sequence is of particular importance. (orig.) [de

  10. Dose reduction in coronary artery imaging with 64-row multi-slice helical CT with body mass index-dependent mA selection

    International Nuclear Information System (INIS)

    Gao Jianhua; Wang Guisheng; Zheng Jingchen; Li Jianying; Sun Xianchang; Gao Caihong; Dai Ruping

    2008-01-01

    Objective: To evaluate the robustness of body mass index (BMI) adapted tube current selection method for obtaining consistent image quality in MSCT coronary artery imaging. Methods: Initially one hundred patients in the control group (C group) underwent cardiac scans using GE 64-row VCT with standard scan protocol (640 mA, 120 kV, 0.35 sec, body bowtie, C 2 filter). Noise measurement was obtained for each patient using the average of three consecutive slices in the ascending aorta with ROI of 10 mm x 10 mm to establish the relationship between BMI, desired image noise (IN) and required mA. An excel table was established to predict the required mA to achieve a desired IN for each patient with different BMI. A second group of one hundred cardiac patients (L group) was scanned with BMI-adapted mA from the table to evaluate the practicability of this method. BMI, IN, CT dose index (CTDI), effective dose (ED) were all recorded. Results: For the control group of 100 patients, the mean values and standard deviations of image quality score (IQS), BMI, IN and ED were 3.71±0.54, 25.08±2.63, 24.56±5.03 and (17.63±1.68) mSv (with range of 15-22 mSv). Regression analysis indicated linear relationship between BMI and image noise with fixed mA. Using the relationship between tube current and image noise and noise ratio between large bowtie and cardiac bowtie, the following equation for the required tube current Xma to achieve present image noise of INa for patient with certain BMI value when using cardiac bowtie could be then obtained: Xma=Fma x [(k 1 x BMI + c 1 )/Ina] 2 , where Fma=640 mA, k 1 =1.033, c 1 = -3.2, INa=27 in the study. (2) For the patients in L group, the mean values and standard deviations of IQS, BMI, and IN were 3.69±0.53, 25.07±2.91, and 26.61±3.44, respectively. The average tube current used was (469.95±113.45) mA, depending on patient's BMI values. The average effectively dose was (9.08±2.25) mSv. There was no statistically difference between the

  11. Development and performance evaluation of an experimental fine pitch detector multislice CT scanner.

    Science.gov (United States)

    Imai, Yasuhiro; Nukui, Masatake; Ishihara, Yotaro; Fujishige, Takashi; Ogata, Kentaro; Moritake, Masahiro; Kurochi, Haruo; Ogata, Tsuyoshi; Yahata, Mitsuru; Tang, Xiangyang

    2009-04-01

    The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction) x 32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI(vol) of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

  12. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  13. Pulmonary hypertension CT imaging

    International Nuclear Information System (INIS)

    Nedevska, A.

    2013-01-01

    Full text: The right heart catheterization is the gold standard in the diagnosis and determines the severity of pulmonary hypertension. The significant technical progress of noninvasive diagnostic imaging methods significantly improves the pixel density and spatial resolution in the study of cardiovascular structures, thus changes their role and place in the overall diagnostic plan. Learning points: What is the etiology, clinical manifestation and general pathophysiological disorders in pulmonary hypertension. What are the established diagnostic methods in the diagnosis and follow-up of patients with pulmonary hypertension. What is the recommended protocol for CT scanning for patients with clinically suspected or documented pulmonary hypertension. What are the important diagnostic findings in CT scan of a patient with pulmonary hypertension. Discussion: The prospect of instantaneous complex - anatomical and functional cardiopulmonary and vascular diagnostics seems extremely attractive. The contrast enhanced multislice computed (CT ) and magnetic resonance imaging are very suitable methods for imaging the structures of the right heart, with the possibility of obtaining multiple projections and three-dimensional imaging reconstructions . There are specific morphological features that, if carefully analyzed, provide diagnostic information. Thus, it is possible to avoid or at least reduce the frequency of use of invasive diagnostic cardiac catheterization in patients with pulmonary hypertension. Conclusion: This review focuses on the use of contrast-enhanced CT for comprehensive evaluation of patients with pulmonary hypertension and presents the observed characteristic changes in the chest, lung parenchyma , the structures of the right half of the heart and pulmonary vessels

  14. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  15. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  16. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  17. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  18. Assessment of multislice CT to quantify pulmonary emphysema function and physiology in a rat model

    Science.gov (United States)

    Cao, Minsong; Stantz, Keith M.; Liang, Yun; Krishnamurthi, Ganapathy; Presson, Robert G., Jr.

    2005-04-01

    Purpose: The purpose of this study is to evaluate multi-slice computed tomography technology to quantify functional and physiologic changes in rats with pulmonary emphysema. Method: Seven rats were scanned using a 16-slice CT (Philips MX8000 IDT) before and after artificial inducement of emphysema. Functional parameters i.e. lung volumes were measured by non-contrast spiral scan during forced breath-hold at inspiration and expiration followed by image segmentation based on attenuation threshold. Dynamic CT imaging was performed immediately following the contrast injection to estimate physiology changes. Pulmonary perfusion, fractional blood volume, and mean transit times (MTTs) were estimated by fitting the time-density curves of contrast material using a compartmental model. Results: The preliminary results indicated that the lung volumes of emphysema rats increased by 3.52+/-1.70mL (pemphysema rats decreased by 91.76+/-68.11HU (pemphysema rats were 0.25+/-0.04ml/s/ml and 0.32+/-0.09ml/s/ml respectively. The fractional blood volumes for normal and emphysema rats were 0.21+/-0.04 and 0.15+/-0.02. There was a trend toward faster MTTs for emphysema rats (0.42+/-0.08s) than normal rats (0.89+/-0.19s) with ppulmonary emphysema appears promising for small animals.

  19. Measurement and analysis of cardiopulmonary vascular in Lanzhou healthy adults with multislice spiral CT

    International Nuclear Information System (INIS)

    Shi Xiaonan; Guo Shunlin

    2013-01-01

    Objective: To constitute a normal standard of cardiopulmonary vascular diameter and size of normal adult in Lanzhou, and to compared with the other's data reported in the previous bibliography by measuring diameter and area of cardiopulmonary artery lumen of the healthy adults in Lanzhou with multislice spiral CT (MSCT). Methods: Three hundred Lanzhou adults with no cardiopulmonary disease were equally assigned to 3 groups according to their age (A group: 18-39 years, B group: 40-60 years, C group: 61-80 years; 50 females and 50 males in each group). CT data were acquired at the end of deep inspiration phase and measurements were done on 3D reconstruction image with precise landmarks. All the results were statistically analyzed. Results: The diameters and areas of the main pulmonary artery left pulmonary artery right pulmonary artery ascending aorta and descending aorta differed significantly among the 3 groups (P<0.05). In groups B and C, there were significant differences in diameters and areas of pulmonary artery left pulmonary artery and right pulmonary between different genders (P<0.05). Conclusion: Imaging standard is provided for Lanzhou adult in early diagnosis of cardiopulmonary disease. The diameters and areas of main pulmonary artery left pulmonary artery and right pulmonary artery of Lanzhou healthy adults are different from that of other regions. It may be related to the geographical environment and the state of air pollution in Lanzhou. (authors)

  20. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction

    International Nuclear Information System (INIS)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E.; Merten, H.A.

    2002-01-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [de

  1. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M; Favazza, Christopher P; Leng, Shuai; Kupinski, Matthew A; McCollough, Cynthia H

    2017-08-01

    Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading. A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at five dose levels (CTDI vol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models. Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product-moment correlation coefficient R = 0.972, 95% confidence

  2. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0

  3. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  4. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  5. Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT

    International Nuclear Information System (INIS)

    Gao Jianhua; Li Tao; Mi Fengtang; Li Na; Cui Ying; Dai Ruping; Li Jianying

    2009-01-01

    Objective: To characterize the association between the mean CT value on a scout view and the dependent mA selection method, and to evaluate the clinical value of a mA selection method based on scout view mean CT value in obtaining individualized scan protocol and consistent image quality for patient population on 64-row MSCT CT coronary angiography (CTCA). Methods: One hundred patients (group A) underwent CTCA consecutively using standard protocol with a fixed mA. The mean CT value of a fixed ROI (region of interest) from the scout AP view and the CTCA image noise (standard deviation on the root of ascending aorta) were measured. The correlation between CT values and noise was studied to establish a formula and a list to determine the required mA for obtaining a consistent CTCA image noise based on the measured SV CT value. Another 100 patients (group B) were scanned using the same parameters as group A except the mA and the CT value was also measured. The mA was determined by the list established previously. The CTCA image quality (IQ) as well as the image noise (IN) and the effective dose (ED) from the two groups were statistically analyzed using t-test. The CT findings for the 32 patients in the group B were also compared with the selective coronary angiography (SCA) results. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CTCA for detection of significant stenosis were obtained. Results: The formula between the required mA and the CT value was: XmA=FmA x [(K 1 x CTscout + C 1 )/INa] 2 . The CTCA images in B group had statistically higher IN (27.66±2.57, 22.22±4.17, t=11.33, P=0.000), but no statistical difference between IQ scores for the two groups (3.29±0.66, 3.37±0.67, t=0.009, P=0.990), and ED [(8.72±2.51) versus (12.53±0.90) mSv] was 30% lower for the B group (P<0.01). For the 32 patients in the B group who had SCA, the CTCA sensitivity, specificity, positive predictive value, negative

  6. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  7. The role of multi-slice CT in preoperative staging of colonic tumors

    International Nuclear Information System (INIS)

    Zhang Miao; Chen Kemin; Zhao Zehua; Ling Huawei

    2005-01-01

    Objective: To determine the accuracy of multi-slice CT pneumocolon in the staging of colonic carcinomas. Methods: Thirty-six patients, who were strongly suspected to have colonic disorders, underwent CT pneumocolon before and after intravenous injection of iodinated contrast agent. CTVE, MPR, SSD, and Raysum images were then obtained by using 4 different softwares in workstation (ADW3.1). 33 positive cases were staged preoperatively according to TNM standard. All cases were proved by surgical or colonoscopic histology. Sensitivity and accuracy of MSCT were determined for the detection of cancers, lymph nodes, and metastases. Results: MSCT pneumocolon examinations demonstrated 32 lesions, missing one case. Sensitivity and positive accuracy value for T staging were 96.97% (32/33) and 87.88% (29/33), respectively; Sensitivity and positive accuracy value for lymph node involvement were 73.91% (17/23) and 69.57% (16/23), respectively. The density of metastatic lymph node was higher than that of normal one. Five cases in M stage were all diagnosed correctly. Conclusion: MSCT pneumocolon is a better method of depicting the colorectal carcinoma. It allows for accurate staging of the colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. However the value for early T staging in colorectal carcinoma and minute metastasis of lymph nodes is limited. It is helpful to combine all the findings of lymph nodes, including the size, density, and location, to make a correct diagnosis. (authors)

  8. Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

    International Nuclear Information System (INIS)

    Greess, H.; Lutze, J.; Noemayr, A.; Bautz, W.; Wolf, H.; Hothorn, T.; Kalender, W.A.

    2004-01-01

    The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as ''very good,'' ''good,'' ''diagnostic'' and ''poor'' in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. (orig.)

  9. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    International Nuclear Information System (INIS)

    Liang Xin; Jacobs, Reinhilde; Hassan, Bassam; Li Limin; Pauwels, Ruben; Corpas, Livia; Souza, Paulo Couto; Martens, Wendy; Shahbazian, Maryam; Alonso, Arie

    2010-01-01

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  10. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xin, E-mail: Xin.Liang@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); College of Stomatology, Dalian Medical University (China); Jacobs, Reinhilde, E-mail: Reinhilde.Jacobs@uz.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Hassan, Bassam, E-mail: b.hassan@acta.n [Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam (Netherlands); Li Limin, E-mail: Limin.Li@uz.kuleuven.b [Department of Paediatric Dentistry and Special Dental Care, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Pauwels, Ruben, E-mail: Ruben.Pauwels@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Corpas, Livia, E-mail: LiviaCorpas@gmail.co [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Souza, Paulo Couto, E-mail: Paulo.CoutoSouza@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Martens, Wendy, E-mail: wendy.martens@uhasselt.b [Department of Basic Medical Sciences, Faculty of Medicine, University of Hasselt, Diepenbeek (Belgium); Shahbazian, Maryam, E-mail: Maryam.Shahbazian@student.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Alonso, Arie, E-mail: ariel.alonso@uhasselt.b [Department of Biostatistics and Statistical Bioinformatics, Universiteit Hasselt (Belgium)

    2010-08-15

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  11. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  12. To evaluate vascular complications of transplant kidney examined by multislice spiral CT angiograph

    International Nuclear Information System (INIS)

    Peng Qian; Fan Miao; Luo Xiaomei

    2008-01-01

    Objective: To evaluate the value of multislice CT angiography (MSCTA) in vascular complications of transplant kidney. Methods: Six transplant kidneys were undergone enhanced MSCT scanning postoperation. MPR, CPR, VR and VP reformation were performed to observe transplant kidney's parenchyma, renal artery, and renal vein. To analysis all the reconstruction technique and find the advantage and shortage of them. Results: One case showed enhanced function of transplant kidney decreased. Vascular stenosis was found in one case and false aneurysm was found in another transplant kidney. Transplant kidney were enhanced normal in the left three cases. MPR couldn't reconstruct all the tortuous vessel of renal hilus in one plane. But all six cases could expose the vessel of renal hilus very clearly in coronal section and sagittal plane of CPR. Six cases of VR could observe the vessel direction and lesions outside vessel through rotate the reconstruction image. VP could see through inside the vessel of transplant kidney. Conclusion: MSCTA has an important role as an imaging technique to evaluate vascular complications of transplant kidney, it can replace DSA. (authors)

  13. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  14. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  15. Multi-slice CT features of annular pancreas in neonates

    International Nuclear Information System (INIS)

    He Mingqing; Zhu Youzhi; Hu Kefei; Yin Chuangao; Hu Jun; Wang Song; Li Xu; Lu Zhongbin; Wang Yue; Liu Xiang

    2013-01-01

    Objective: To investigate the MSCT manifestations and their values in the diagnosis of annular pancreas in neonates. Methods: Retrospective analysis of clinical and CT findings in 27 cases with surgery-proved annular pancreas in neonates was made. The unenhanced and contrast-enhanced CT images were obtained in 20 patients. Two experienced radiologists determined the site and degree of obstruction, the relationship between the head of the pancreas and the obstruction point, and the surrounding tissue structure. Results: The direct signs included the fluid-filled or gas-filled bowel in the head of pancreas in 4 cases, the enhancement of surrounding soft tissue as enhanced pancreas in 17 cases, disappearance of the fat gap between the intestinal wall and the annular pancreas in 17 cases. The indirect signs included intestinal obstruction in 20 cases, 'single-bubble sign' in 2 cases, 'double-bubble sign' in 18 cases, the distal bowel without gas in 5 cases, small amount of gas in the distal bowel in 15 cases. In 12 of 18 cases showing 'double-bubble sign', the ratio of duodenal bubble diameter (Dd) to stomach bubble diameter (Ds)was over 1.0. The site of obstruction was located in the descending duodenum in 20 cases. The form of obstructed point presented with 'nipple sign' in 15 cases, with 'the mouse tail' in 5 cases. The expansion bowel was located in the head of pancreas in 1 case. Gas was found in the pancreatic duct in 1 case, and 'swirl sign' was shown in 2 cases. Conclusions: MSCT combined with three-dimensional reconstruction techniques can clearly demonstrate the annular pancreas' s shape, the site and degree of obstruction and other malformations. It can provide important information for clinical treatment. (authors)

  16. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  17. Application of low dose multi-slice helical CT in orbital trauma patients

    International Nuclear Information System (INIS)

    Yang Rui; Dai Limei; Li Jianying; Wang Fengyan; Du Guoquan

    2010-01-01

    Objective: To investigate the most appropriate low radiation dose in multi-slice CT (MSCT) scans for orbital trauma patients. Methods: Thirty trauma patients with suspected orbital fractures who underwent helical CT scans with a 64-MSCT using regular dose were selected. Noise was artificially introduced to the axial images using an image space noise addition tool to simulate 6 sets of lower dose scans with tube current of 30, 70, 100, 140, 170 and 200 mA, respectively. The lowest tube current with adequate image quality for confident diagnosis was determined based on the evaluation of the overall image quality and fracture detection on images at different dose levels. The determined lowest tube current was then validated using clinical scans. Radiation dose related parameters CTDIvol, DLP, ED were also recorded. Image quality was evaluated according to its low-density resolution, noise and structure clarity and characterized into 5-grades of excellent, good, fair, worse and worst. Rank sum test and χ 2 test were used for statistics. Results: In 30 trauma patients with regular dose of 300 mA, there were 30 cases of orbital fracture, 19 cases of intraorbital emphysema, 12 cases of ocular muscle injury and 1 case of intraorbital foreign body. These changes could still be clearly observed and correctly diagnosed when the tube current was reduced to as low as 70 mA. However, the overall image quality was mostly fair. At the simulated dose of 100 mA, the majority of images were characterized as excellent or good, and there was no statistical difference compared with that of regular dose scans (P>0.05). In the clinical evaluation for 20 orbital trauma patients with the reduced tube current of 100 m A , the majority of images were judged to be excellent (9 cases) or good (17 cases) and fair (4 cases). The radiation dose (0.29 mSv) was reduced by 70% compared with that of regular tube current of 300 mA (0.86 mSv). Conclusion: The tube current of MSCT may be used as low as

  18. Multislice CT enteroclysis in the diagnosis of bowel endometriosis

    International Nuclear Information System (INIS)

    Biscaldi, Ennio; Rollandi, Gian A.; Ferrero, Simone; Ragni, Nicola; Remorgida, Valentino; Fulcheri, Ezio

    2007-01-01

    This prospective study aims to evaluate the efficacy of multislice computed tomography combined with colon distension by water enteroclysis (MSCTe) in determining the presence and depth of bowel endometriotic lesions. Ninety-eight women with symptoms suggestive of colorectal endometriosis underwent MSCTe; locations, number of nodule/s, size of the nodule/s and depth of bowel wall infiltration were determined. Independently from the findings of MSCTe, all women underwent laparoscopy. MSCTe findings were compared with surgical and histological results. Abnormal findings suggestive of bowel endometriotic nodules were detected by MSCTe in 75 of the 76 patients with bowel endometriosis. MSCTe identified 110 (94.8%) of the 116 bowel endometriotic nodules removed at surgery; 6 nodules missed at MSCTe were located on the rectum. MSCTe correctly determined the degree of infiltration of the bowel wall in all of the 34 serosal bowel nodules identified at MSCTe. In six nodules reaching the submucosa, the depth of infiltration was underestimated by MSCTe. MSCTe had a sensitivity of 98.7%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 95.7% in identifying women with bowel endometriosis. MSCTe is effective in determining the presence and depth of bowel endometriotic lesions. (orig.)

  19. Multislice CT enteroclysis in the diagnosis of bowel endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Biscaldi, Ennio; Rollandi, Gian A. [' ' Duchesse of Galliera' ' -Hospital, Genoa (Italy). Dept. of Radiology; Ferrero, Simone; Ragni, Nicola; Remorgida, Valentino [San Martino Hospital and Genoa Univ. (Italy). Dept. of Obstretics and Gynaecology; Fulcheri, Ezio [San Martino Hospital and Genoa Univ. (Italy). Unit of Anatomy and Histopathology

    2007-01-15

    This prospective study aims to evaluate the efficacy of multislice computed tomography combined with colon distension by water enteroclysis (MSCTe) in determining the presence and depth of bowel endometriotic lesions. Ninety-eight women with symptoms suggestive of colorectal endometriosis underwent MSCTe; locations, number of nodule/s, size of the nodule/s and depth of bowel wall infiltration were determined. Independently from the findings of MSCTe, all women underwent laparoscopy. MSCTe findings were compared with surgical and histological results. Abnormal findings suggestive of bowel endometriotic nodules were detected by MSCTe in 75 of the 76 patients with bowel endometriosis. MSCTe identified 110 (94.8%) of the 116 bowel endometriotic nodules removed at surgery; 6 nodules missed at MSCTe were located on the rectum. MSCTe correctly determined the degree of infiltration of the bowel wall in all of the 34 serosal bowel nodules identified at MSCTe. In six nodules reaching the submucosa, the depth of infiltration was underestimated by MSCTe. MSCTe had a sensitivity of 98.7%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 95.7% in identifying women with bowel endometriosis. MSCTe is effective in determining the presence and depth of bowel endometriotic lesions. (orig.)

  20. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  1. Correlation study of multislice spiral CT and pathology in relationship between solitary pulmonary nodule and bronchus

    International Nuclear Information System (INIS)

    Qiang Jinwei; Ye Xuanguang; Zhou Kangrong; Jiang Yaping; Wang Qun; Xu Songtao; Tan Lijie

    2003-01-01

    Objective: To investigate the relationship between solitary pulmonary nodule (SPN) and bronchus and its value in predicting the nature of nodule. Methods: Continuous volume targeted scans of 0.5 mm collimation were prospectively performed with multislice spiral CT (MSCT) and reconstructed images of MPR, CPR, and SSD in workstation in 75 patients of SPN with ≤3 cm in diameter were acquired. The emphasis was paid on the manifestation of the shapes and patterns of SPN with related bronchi. The results were correlated with macroscopic and microscopic specimens. Results: (1) The SPN-bronchus relationship was shown very clearly in all patients by the designed protocol. CT demonstrated the relations between SPN and bronchus in 44 (86.3%) malignant and 16 (66.7%) benign nodules. There was no statistically significant difference (P=0.065). (2) Five types of SPN-bronchus relationship were identified with MSCT. Type I: bronchus was obstructed abruptly by the SPN, type II: bronchus penetrated into SPN with tapered narrow and interruption, type III: bronchus lumen shown within SPN was patent and intact, type IV: bronchus ran at the periphery of SPN with intact lumen, and type V: bronchus was displaced, compressed, and narrowed by SPN. (3) With respect to the nature of SPN, malignant nodule most commonly showed type I, secondly type IV, and rarely type V. Benign nodule most often showed type V, secondly type I, and no type II. With respect to the pattern, type I, II, and IV patterns were more commonly seen in malignant nodule, whereas type V pattern was seen frequently in benign nodule. Type III pattern was slightly more common in benign cases. Conclusion: Spiral targeted scan of ultra-thin section with MSCT and followed by MPR, CPR, and SSD reconstruction can greatly improve the manifestation of the bronchioles and accurately demonstrate the patterns of SPN-bronchus relationship. Varied patterns are corresponding to certain nodule and reflect definite pathologic changes

  2. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  3. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  4. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  5. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  6. Value of multi-slice CT in the classification diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Yi; Zeng Mengsu; Ling Zhiqing; Rao Shengxiang; Liu Yalan

    2008-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) classification in the assessment of the hilar cholangiocarcinoma resectability. Methods: Thirty patients with surgically and histopathologically proved hilar cholangiocarcinomas who underwent preoperative MSCT and were diagnosed correctly were included in present study. Transverse images and reconstructed MPR images were reviewed for Bismuth-Corlette classification and morphological classification of hilar cholangiocarcinoma. Then MSCT classification was compared with findings of surgery and histopathology. Curative resectabilty of different types according to Bismuth-Corlette classification and morphological classification were analyzed with chi-square test. Results: In 30 cases, the numbers of Type I, II, IIIa, IIIb and IV according to Bismuth-Corlette classification were 1, 3, 4, 5 and 17. Seventeen patients underwent curative resections, among which 1, 2, 1, 4 and 9 belonged to Type I, II, IIIa, IIIb and IV respectively. However, there was no significant difference in curative resectability among different types of Bismuth-Corlette classification (χ 2 = 0.9875, P>0.05). In present study, the accuracy of MSCT in Bismuth-Corlette classification reached 86.7% (26/30). The numbers of periductal infiltrating, mass forming and intraductal growing type were 13, 13 and 4, while 6, 8 and 3 cases of each type underwent curative resections. There was no significant difference in curative resectability among different types of morphological classification (χ 2 =1.2583, P>0.05). The accuracy of MSCT in morphological classification was 100% (30/30) in this study group. Conclusion: MSCT can make accurate diagnosis of Bismuth-Corlette classification and morphological classification, which is helpful in preoperative respectability assessment of hilar cholangiocarcinoma. (authors)

  7. The study on three-dimensional measurement of the Human Eustachian tube examined by Multislice CT

    International Nuclear Information System (INIS)

    Yoshioka, Satoshi; Naito, Kensei; Fujii, Naoko; Katada, Kazuhiro; Takeuchi, Kenji

    2007-01-01

    Morphological aberration of the Eustachian tube is a significant factor of various middle ear diseases. Traditionally, cadaveric specimens have been used for studies on the morphology of Eustachian tubes. However, this approach was not too efficient, as samples were limited in number as they were difficult to obtain, and biological conditions were not reflected due to rigor mortis and atrophy during specimen preparation. We thus decided to use Multi-Slice CT (MSCT) to perform 3-dimensional (3-D) anatomic measurements of the Eustachian tube. MSCT has benefits of isotropy and high resolution, and it is useful in preparing images of any plane. Forty-eight adults were studied. For the purpose of measurement, various anatomic indices were carefully and precisely defined to identify each area on the image. Calculations based on each coordinate value enabled the measurement of length, diameter and angle of the Eustachian tube of normal adults. Therefore, measurements of the Eustachian tube, which were traditionally difficult as it is located in the deep part of the cranium, were simplified in many specimens. Mean value of total length was 39.2±3.2 mm, cartilage part length of the tube 30.0±2.7 mm and bony part 9.2±1.6 mm. Mean values of diameter of tympanic orifice were 5.2 x 3.2 mm, and pharyngeal orifice 9.7 x 4.4 mm. Mean value of angle between bony part and cartilage part was 160.9±13.6 degrees. This approach to anatomic measurement is expected to contribute greatly to investigation on various middle ear diseases. (author)

  8. Demonstration of the right inferior phrenic artery by using multislice helical CT

    International Nuclear Information System (INIS)

    Zhao Shaohong; Liu Xin; Cai Zulong; Zhao Hong; Yang Li

    2006-01-01

    Objective: To demonstrate the origin of the right inferior phrenic artery (RIPA) in normal and hepatocellular carcinoma (HCC) patients and provide valuable anatomical information for angiographers before and after transcatheter arterial chemoembolization (TACE). Methods: Four hundred and forty consecutive patients including 133 HCC cases who had biphase abdominal CT were assessed in this study. The routine abdominal enhanced CT scan (GE, LightSpeed16) was performed with 120 kV, 200-240 mAs, 10 mm collimation, 1.375 pitch, and 10 mm reconstruction interval at 22-25 seconds for arterial phase triggered by timing bolus, 60 seconds for portal venous phase after injection of 100 ml contrast material (300 mg I/ml) at a rate of 3.5 ml/s. Multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images were generated using 1.25 mm images reconstructed with 1 mm interval in arterial phase and reviewed by two radiologists. An enhanced artery medial-posterior to the IVC, originated from aorta or its branches to the diaphragmatic dome was interpreted as the RIPA. Results: The RIPA was showed in all 440 patients (100%). Among 218 (49.5%) RIPAs originated from the aorta, 140 were from the fight side of the aorta, 22 from the left side of the aorta, 56 from the anterior wall of the aorta, 36 RIPAs had the same origin with the left inferior phrenic artery. Among 138 (31.4%) RIPAs from the celiac artery, 10 RIPAs had the same origin with the left gastric artery, and 33 RIPAs had the same origin with the left inferior phrenic artery. 78 (17.7%) were from the fight renal artery, 6 (1.4%) were from the left gastric artery (the left gastric artery from aorta). The dilatation of the RIPA was demonstrated in 16 of 133 hepatocellular carcinoma patients. Conclusion: Multislice helical CT could demonstrate the origin of the RIPA in arterial phase and provide useful anatomical information for angiographer before and after TACE. (authors)

  9. Multislice CT as a Primary Screening Tool for the Prediction of an Involved Mesorectal Fascia and Distant Metastases in Primary Rectal Cancer : A Multicenter Study

    NARCIS (Netherlands)

    Wolberink, Steven V. R. C.; Beets-Tan, Regina G. H.; de Haas-Kock, Danielle F. M.; van de Jagt, Eric J.; Span, Mark M.; Wiggers, Theo

    PURPOSE: The purposes of this study were to assess whether multislice CT can identify tumors having a free or involved circumferential margin, to investigate the additional role of multislice CT as a "one-stop shopping'' staging tool for staging nodal and distant metastases. METHODS: A total of 250

  10. Evaluation of gastrointestinal stromal tumors by multislice computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Porto, Fabiano Elias; Baroni, Ronaldo Hueb; Rocha, Manoel de Souza; Funari, Marcelo Buarque de Gusmao; Macedo, Antonio Luiz de Vasconcellos; Pelizon, Christina Helena de Toledo

    2005-01-01

    This article presents three cases of gastrointestinal stromal tumors with clinical manifestations and pathological features, along with differential diagnoses, with special emphasis on multislice computed tomography and magnetic resonance imaging findings. (author)

  11. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-10-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  12. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    International Nuclear Information System (INIS)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko

    2001-01-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  13. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  14. Studies on intracranial collateral circulation with multi-slice CT angiography in patients with symptomatic cerebral artery stenosis

    Directory of Open Access Journals (Sweden)

    Shu-qing ZHOU

    2011-06-01

    Full Text Available Objective To explore the features of intracranial collateral circulation in patients with symptomatic cerebral artery stenosis.Method Ninety-four patients with ischemic cerebrovascular disease admitted from Apr.2004 to Jun.2009 were involved in present study.All the patients were examined with cerebral multi-slice CT angiography,and the features of cerebral artery stenosis and intracranial collateral circulation were evaluated using maximum intensity projection(MIP and volume rendering(VR images of CT angiography.Result Of the 94 patients involved,48 were diagnosed as cerebral artery stenosis,including 29 cases of cerebral infarction,18 of transient ischemic attack(TIA and 1 of moyamoya disease(MMD.Among the 14 cases of severe cerebral artery stenosis or occlusion,cerebral infarction was found in 6 cases with lesser intracranial collateral vessels(including massive cerebral infarction in 4 cases and watershed infarction in 2 cases,and focal infarction of central semi-ovale in 1 case and TIA in 7 cases were found with abundant intracranial collateral vessels.Multiple lacunar infarction was found in 22 cases of mild or moderate cerebral artery stenosis,but there was no significant correlation between the stenosed arteries and infarction sites.Abundant intracranial collateral vessels were found in one patient with Moyamoya disease but no infarction was observed.Conclusions Intracranial collateral circulation plays an important role of compensation in patients with severe cerebral artery stenosis or occlusion.Cerebral angiography with multi-slice CT is of great significance in evaluation of cerebral artery stenosis and intracranial collateral circulation.

  15. Clinical application of multislice CT enterography with hypertonic mannitol saline as oral contrast

    International Nuclear Information System (INIS)

    Yan Guixin; Wang Haitao; Chen Wenjing; Liu Wenya

    2011-01-01

    Objective: To assess the feasibility and value of multislice CT enterography (MSCTE) with large dose economy and convenience orally administered hypertonic mannitol salt water (2.5% mannitol and 1.5% NaCl salt water) as negative contrast in demonstrating normal and abnormal small bowel. Methods: 81 patients suffered from digestive disease and suspected of various kinds of small intestinal diseases were examined (male/female=47/34, 26-81 years old, average 57.8 years). About 1500 ml∼3000 ml hypertonic mannitol saline was oral administered within 90 minutes and 20 mg of raceanisodamine hydrochloride injection was injected intramuscularly. CT scanning was performed 20 minutes later. Imaging data were post processed with coronal, sagittal and oblique reconstruction, multiplanar reformation (MPR), maximum intensity projection (MIP), and volumer rendering technique (VRT). The filling degree of stomach, intestine and colon was classified as satisfactory, better and unsatisfactory. The length and superposition of small intestine was classified as dense-type, uniformity-type and straggling-type. The maximum outer diameters of duodenum, jejunum, and ileum were measured respectively in different segments. The degree of bowel wall enhancement in arterial phase and venous phase was classified as obvious enhancement (>90 HU), medium enhancement (60-90 HU) and mild enhancement (<60 HU). CT features of various kinds of small bowel diseases were analyzed. Results: The hypertonic mannitol saline was acceptable by patients, except 5 patients with diarrhea. The filling degree of stomach, intestine and and colon was classified as satisfactory in 46 cases, better in 23 cases and unsatisfactory in 12 cases. The maximum outer diameters of small bowel in different segments were 24 mm ± 4.5 mm at duodenum, 24 mm ±3.9 mm at jejunum and 23 mm ±3.3 mm at ileum respectively. The length and superposition of small intestine were classified as dense-type in 7 cases, uniformity-type in 58

  16. Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results

    International Nuclear Information System (INIS)

    Greess, H.; Bautz, W.; Baum, U.; Wolf, H.; Suess, C.; Kalender, W.A.

    2004-01-01

    Purpose: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. Materials and Methods: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n=26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. Results: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31% to 66% in children (mean 44%) and between 35% and 64% in adults (mean 53%), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. Conclusion: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality. (orig.) [de

  17. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  18. Contrast-enhanced multislice pneumo-CT-cystography in the evaluation of urinary bladder neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)], E-mail: scardapane@aruba.it; Pagliarulo, Vincenzo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Ianora, Amato A. Stabile [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy); Pagliarulo, Arcangelo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Angelelli, Giuseppe [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)

    2008-05-15

    Purpose: To evaluate the accuracy of contrast-enhanced multislice CT (MSCT) in the study of urothelial tumors after distension of the bladder with air. Materials and methods: We evaluated 43 consecutive patients with endoscopically proven bladder lesions. After air distension of the bladder, unenhanced pelvic and enhanced abdomino-pelvic scans were obtained with the following protocol: thickness 2.5 mm x 4 mm, increment 1 mm, scan delay 40'' and 7-10 min. For each patient we considered the number, size, aspect (papillary or sessile) and contrast enhancement of lesions. Ureteral involvement and the presence of synchronous lesions in the excretory scan were also evaluated. MPR and virtual endoscopy images were reviewed in all cases. Results: Bladder lesions were visualized in 39/43 cases. Compared to conventional cystoscopy, MSCT recognized single lesions in 31/33 patients, two lesions in 4/6, three in 2/2 and more than five foci in 2/2 patients. A papillary aspect was described in 44 cases while 11 lesions were sessile. Conventional Cystoscopy recognized six more lesions as compared with MSCT (four flat and two small papillary lesions). The detection rate for protruding lesions was 100% (52/52) for lesions > 5 mm and 60% (3/5%) for lesions < 5 mm. In four patients hydronephrosis was present, while in one case a synchronous lesion was evident in the renal pelvis. Conclusion: Contrast-enhanced MSCT with air distension of the urinary bladder is a safe and complete investigation to evaluate the local stage of bladder cancer and to evaluate the ureteral extension of the tumor, as well as the presence of synchronous lesions.

  19. The value of multi-slice spiral CT in the preoperative assessment of living renal donor

    International Nuclear Information System (INIS)

    Li Qinghai; Yan Fuhua; Xu Pengju; Zhou Meiling; Zhu Tongyu; Xu Ming; Wang Guomin

    2008-01-01

    Objective: The purpose of this study is to assess the value of multi-slice spiral CT (MSCT) in the preoperative evaluation of living renal donor as a all in one modality. Methods: Thirty-six potential living renal donors underwent the examination using a GE light VCT scanner. Informed consent was obtained from all participants. The plain scan, early arterial phase, late arterial phase and excretory phase scans are performed in the former 25 donors (injection rate 5 rolls, total volume 100 mi, tube tension 120 kV). While in the later 11 donors (2 ml/s 40 ml +4 ml/s 60 ml), the scanning protocol included the plain scan ( 100 kV), vascular phase and excretory phase scans (100 kV). The excretory phase data were used in the reconstruction of CT urography in both groups. All images were reviewed by one radiologist and one urologist, and the findings of MSCT were compared with intraoperative findings for 33 donors, to investigate the utilities of MSCT in assessing renal vascularity, urinary tract and lesions of renal parenchyma. When discrepancies are found between the two reviewers, consensus was obtained via discussion. Au data was statiscally processed with SPSS for Windows. Results: MSCT angiography is in accordance with intraoperative findings in demonstrating the anatomy of renal arteries and renal vein trunk, accesary arteries, early branching of renal artery. The findings from CTA are highly in accordance with the intraoperative findings, which facilitate intraoperative ligation and reduce relevant complications. CTU demonstrates the anatomy of urinary, tract in good agreement with the intraoperative findings. The image quality of 3D vascularity and CTU between the two groups, scored 4.4 ± 1.2 vs 4.2 ± 1.3 and 4.6 ± 0.8 vs 4.4 ± 0.9 respectively, no statistical between-groups difference was found (Z=-0.89, -0.47, P>0.05). Conclusion: MSCT multiphase scanning combined with CTA and CTU play a important role in the evaluation of living renal donor, which

  20. Value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Wang Kang; Zhao Zehua; Wang Zhi; Wang Weizhong; Xu Songsen; Zhang Miao; Liu Wenjin; Zhang Guozhen; Feng Dianxu

    2005-01-01

    Objective: To investigate the value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis. Methods: A total of 39 patients with clinically suspected acute appendicitis underwent surgery from February, 2002 to September, 2003. They were prospectively examined before surgery with routine CT scanning and MPVR reconstruction spiral CT. 31 cases of appendicitis were confirmed after appendectomy. CT scans and surgery-pathology reports were evaluated on a five-grade scale from hyperemic-edematous appendix to abscess (normal appendix: 0 grade). Results: The results of spiral CT MPVR reconstruction were compared with the surgical and pathologic findings at appendectomy, yielding an accuracy of 87.2%, sensitivity of 90.3%, specificity of 75%, positive predictive value of 93.3%, and negative predictive value of 66.7%, respectively. Results of routine CT yielded an accuracy of 38.5%, sensitivity of 38.7%, specificity of 37.5%, positive predictive value of 70.6%, and negative predictive value of 13.6%, respectively. MPVR reconstruction signs of 28 patients with acute appendicitis included enlarged appendix ( > 6 mm) (96.4%), appendicoliths (26.7%), caecal apical thickening (36.7%), periappendiceal inflammation (71.4%), and abscess (10.7%). Conclusion: The use of spiral CT MPVR reconstruction in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to a significant improvement in the preoperative diagnosis and maybe a decrease in surgical-pathologic severity of appendiceal disease. (authors)

  1. Multi-slice CT pulmonary function evaluation in emphysema

    International Nuclear Information System (INIS)

    Ge Xiaojun; Zhang Guozhen; Zhu Yanping; Shan Lin; Mao Dingbiao; Ding Qiyong; Hua Yanqing

    2007-01-01

    Objective: To explore the feasibility of evaluating the lung function by MSCT in emphysema. Methods: The MSCT scan and pulmonary function tests (PFT) were respectively performed in 147 receptors within one week. They were randomly divided into 2 groups: group A (120 receptors), including normal, mild, moderate and severe abnormal pulmonary function based on the PFT, for comparing the correlation between pulmonary quantitative indexes of MSCT pulmonary function and PFT and settingup the primary, grade criteria of abnormal pulmonary, function in emphysema, group B (27 receptors) for evaluating the diagnostic accuracy in group A. The total lung was respectively scanned at the full inspiration and full expiration with MSCT. The pulmonary quantitative indexes of MSCT were measured with Siemens Pulmo pulmonary quantitative software. Results: There was correlation between pulmonary quantitative indexes of MSCT and PFT. The Piex/in -910 showed best correlation with FEV 1 % (r= -0. 905, P -910 (χ 2 0.267, P=0.966, accuracy 81.5%), and the primary criteria for abnormal pulmonary, function of emphysema was normal (0-9.9), mild (10.0-34.9), moderate (35.0-74.9) and severe (≥75.0). Conclusion: It is feasible to evaluate the abnormal lung function of emphysema with pulmonary quantitative indexes of CT. The Piex/in 910 was the most effective one in various indexes. (authors)

  2. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  3. Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections

    Energy Technology Data Exchange (ETDEWEB)

    Remy-Jardin, Martine; Amara, Assia; Campistron, Philippe; Mastora, Ioana; Remy, Jacques [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France); Delannoy, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France)

    2003-05-01

    The aim of this study was to evaluate the accuracy of 3-mm-thick reconstructed sections in the diagnosis of bronchiectasis with multislice CT (MSCT). Forty consecutive patients suspected of bronchiectasis (23 females, 17 males; mean age 51 years) underwent MSCT of the entire thorax with a 4 x 1-mm collimation (120 kV, 0.5 s/rotation, 80 mAs/slice) and a pitch of 1.75. From each data set (mean z-axis coverage: 257 mm; mean duration: 21 s), two series of images were systematically generated: 1-mm (group 1) and 3-mm (group 2)-thick reconstructed scans. Both series of images were obtained at 10-mm intervals and reconstructed with a high-spatial-frequency algorithm. Two observers independently analyzed the presence of bronchiectasis and associated abnormalities in group-1 and group-2 lung images. No significant difference between group 1 and group 2 was found in: (a) the detection of bronchiectasis, identified in 24 patients (60%) in group 1 and in 23 patients (57.5%) in group 2 (p=0.08); (b) the evaluation of the extent of bronchiectasis, identifying focal bronchiectasis in 10 patients (25%) in group 1 and 7 patients (17.5%) in group 2 (p=0.39) and multifocal bronchiectasis in 16 patients (40%) in both groups; (c) the characterisation of bronchiectasis (cylindral bronchiectasis: group 1, n=24, 60%; group 2, n=21, 53%, p=0.08); varicose bronchiectasis: group 1, n=5, 12.5%; group 2, n=6, 15%, p=0.56; and cystic bronchiectasis: group 1, n=2, 5%; group 2, n=2, 5%. Apart from the identification of abnormal bronchial wall thickening (group 2, n=35, 87.5%, vs group 1, n=31, 77.5%, p<0.05), recognition of associated bronchopulmonary anomalies did not differ between the two groups. This study demonstrates a comparable accuracy of the 3- and 1-mm-thick reconstructed scans in the detection and characterization of bronchiectasis. These results suggest the potential usefulness of 3-mm-thick scans generated from 4 x 2.5-mm acquisitions in the screening of bronchiectasis, which would

  4. 16 multi-slice CT three-dimensional and multiplanar reconstruction for evaluation of pediatric congenital scoliosis

    International Nuclear Information System (INIS)

    Peng Yun; Zhang Ningning; Zhang Xuejun; Sun Guoqiang; Zeng Jinjin

    2006-01-01

    Objective: Our study is to use of 16 MSCT three-dimensional images and multiplanar reconstruction images in the preoperative investigation of patients with congenital scoliosis, to study its technical advantage and work out surgical plan. Methods: Twenty-seven pediatric patients with congenital scoliosis processing between April to October 2004 were reviewed, including 13 boys and 14 girls. X-ray plain film and sixteen multi-slice CT examination on curved/standard multiplanar reconstruction and three- dimensional computed tomographic imaging may offer, many potential advantages for defining congenital spine anomalies liable to cause progression of scoliosis, including visualization of the deformity in any plane, from any angle, with the overlying structures subtracted. Results: Ten patients had segmentation defects, 6 patients underwent formation defects, 11 patients had complex, unclassifiable anomalies. The patients of rib deformity were found in 15 patients, the most prominent part of the rib cage deformity was at the same level as the most rotated vertebra in 7 patients; 8 patients had vertebral anomalies accompanied with diastematomyelie, including 6 patients with uncompleted or completed bony spur. In 19 of 27 cases, the muhiplanar reconstruction and three-dimensional images allowed identification of unrecognized malformations and completely evaluated the degree of scoliosis, during conventional X-ray images and axial CT images, including volume 3D imaging evaluated approximately classification and modality of complex anomalies in 11 cases, which were unclassifiable malformation in 7 cases and unsegmented bar with contralateral hemivertebrae; 4 children had segmentation defects revealed unilateral unsegmented bar (3 cases) and bilateral block vertebra (1 case) in volume 3D reconstruction images; 2 children were found occultation hemivertebrae which were not been discovered during conventional X-ray images and axial CT images; and 2 children were revaluated

  5. Multi-slice spiral CT diagnosis of arterial sequestration

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Objective: The purpose of this study was to present the characteristic features on MSCT angiography of arterial sequestration. Methods: The MSCT images of 5 patients with arterial sequestration were retrospectively reviewed. All patients underwent MSCT contrast-enhanced angiography. 3D rendering was made to evaluate the lung parenchyma, bronchial system, and vascular anatomy. Results: All 5 cases demonstrated the anomalous systemic artery (ASA) as an isolated and tortuous artery arising from the descending thoracic aorta, taking a sigmoid course and running along with airway, entering the basal segments of the left lowed lobe. The inferior pulmonary vein (IPV) was significantly engorged. The typical AS was diagnosed in 4 patients. Its ASA intercrossed with the IPV and two branches entering segments 7 and 8 over the IPV, and two branches entering segments 9 and 10 under the IPV. The volume of involved lung shrunk with the artery markedly engorged. A characteristic avascular section was found between the pulmonary artery supplying area and the ASA supplying area, and the bronchi did not accompany the arteries. One was diagnosed atypical AS because of coexistence with bronchial atresia. Conclusion: The arterial sequestration had characteristic MSCT findings. The typical type can be definitely diagnosed, but the atypical type needs further three-dimensional analysis. (authors)

  6. Role of multislice CT and magnetic resonance cholangiography in preoperative evaluation of potential donor in living related liver transplantation

    Directory of Open Access Journals (Sweden)

    Hossam M. Abdel-Rahman

    2016-03-01

    Conclusion: Multislice CT is a valuable tool in the evaluation of potential living liver donors that provides complete information on the hepatic vascular anatomy, the liver parenchyma, and volumetric measurements. MRC with a 3.0-T MR system demonstrates the preoperative biliary evaluation very well with a high accuracy rate.

  7. Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Hara, Ryusuke; Yanagi, Takeshi; Sharp, Gregory C.; Kumagai, Motoki; Asakura, Hiroshi; Kishimoto, Riwa; Yamada, Shigeru; Kandatsu, Susumu; Kamada, Tadashi

    2009-01-01

    Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors.

  8. ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Funke, M.; Obenauer, S.; Baum, F.; Grabbe, E.

    2003-01-01

    AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted κ statistics, extended κ statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended κ=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended κ=0.91 and 0.73, respectively), weighted κ=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not

  9. Impact of Multislice CT Angiography on Planning of Radiological Catheter Placement for Hepatic Arterial Infusion Chemotherapy

    International Nuclear Information System (INIS)

    Sone, Miyuki; Kato, Kenichi; Hirose, Atsuo; Nakasato, Tatsuhiko; Tomabechi, Makiko; Ehara, Shigeru; Hanari, Takao

    2008-01-01

    The objective of this study was to assess prospectively the role of multislice CT angiography (MSCTA) on planning of radiological catheter placement for hepatic arterial infusion chemotherapy (HAIC). Forty-six patients with malignant liver tumors planned for HAIC were included. In each patient, both MSCTA and intra-arterial digital subtraction angiography (DSA) were performed, except one patient who did not undergo DSA. Comparison of MSCTA and DSA images was performed for the remaining 45 patients. Detectability of anatomical variants of the hepatic artery, course of the celiac trunk, visualization scores of arterial branches and interobserver agreement, presence of arterial stenosis, and technical outcome were evaluated. Anatomical variations of the hepatic artery were detected in 19 of 45 patients (42%) on both modalities. The course of the celiac trunk was different in 12 patients. The visualization scores of celiac arterial branches on MSCTA/DSA were 3.0 ± 0/2.9 ± 0.2 in the celiac trunk, 3.0 ± 0/2.9 ± 0.3 in the common hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the proper hepatic artery, 2.9 ± 0.3/2.9 ± 0.4 in the right hepatic artery, 2.8 ± 0.4/2.9 ± 0.4 in the left hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the gastroduodenal artery, 2.1 ± 0.8/2.2 ± 0.9 in the right gastric artery, and 2.7 ± 0.8/2.6 ± 0.8 in the left gastric artery. No statistically significant differences exist between the two modalities. Interobserver agreement for MSCTA was equivalent to that for DSA. Two patients showed stenosis of the celiac trunk on both modalities. Based on these imaging findings, technical success was accomplished in all patients. In conclusion, MSCTA is accurate in assessing arterial anatomy and abnormalities. MSCTA can provide adequate information for planning of radiological catheter placement for HAIC

  10. Comparison of scatter doses from a multislice and a single slice CT scanner

    International Nuclear Information System (INIS)

    Burrage, J. W.; Causer, D. A.

    2006-01-01

    During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer's data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer's data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer's data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT

  11. Vascular involvement in pancreatic carcinoma. Pre-operative assessment by multislice CT angiography

    International Nuclear Information System (INIS)

    Ling Huawei; Guan Yongjing; Ding Bei; Lin Xiaozhu; Zhang Huan; Chen Kemin

    2002-01-01

    Objective: To study the value of multislice CT angiography (MSCTA) in the pre-operative assessment of vascular involvement in pancreatic carcinoma. Methods: 33 cases with pathologically proven pancreatic carcinoma underwent MSCTA prior to surgical intervention. The MSCTA findings in each of the 33 patients were evaluated prospectively by four radiologists. Vascular involvement of pancreatic carcinoma was validated at the time of surgery, which was a reference standard for comparison. Correlation was made between MSCTA findings and surgical results. Results: 11 out of 33 cases with pancreatic carcinoma were considered to be resectable by MSCTA with a positive predictive value of 82% in comparison with surgical findings. MSCTA also had high correlation with surgical results in assessing the non-resectability of pancreatic carcinoma (positive predictive value =95%). Conclusion: MSCTA could delineate the vascular involvement of pancreatic carcinoma with high accuracy and provided valuable information in the preoperative assessment of pancreatic carcinoma

  12. Anomalous origin of coronary artery: the role of multislice CT Angiography: a case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Daniel Rocha; Barros, Marcio Vinicius Lins; Nunes, Maria do Carmo Pereira; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil)

    2012-07-15

    Anomalous origin of coronary arteries is a relatively rare entity and can present different clinical forms. Recently, CT angiography of the coronary arteries have demonstrated an important role in the diagnosis and management of these anomalies. We present the case of a young female without significant comorbidities who presented with cardiopulmonary arrest, being revived by a team of customer service mobile emergency. After completion of multislice CT angiography of the coronary arteries was observed anomalous origin of left main coronary artery in the right coronary artery, no signs of extrinsic compression. Patient received a defibrillator and had an uneventful follow-up performed. Multislice CT angiography is minimally invasive diagnostic methods to detect the origin and trajectory of the coronary arteries, allowing an alternative to cardiac catheterization for evaluation of patients with anomalous origin of coronary arteries. (author)

  13. Multislice CT of the liver. Effects of contrast material pushed with saline solution on hepatic enhancement

    International Nuclear Information System (INIS)

    Sekiguchi, Ryuzo; Hayashi, Takayuki; Tsukamoto, Tatsuaki; Kuroki, Yoshinori; Nasu, Katsuhiro; Murakami, Koji; Nawano, Shigeru

    2004-01-01

    The purpose of this study was to evaluate the usefulness of a method of power injection of contrast material pushed with saline solution for hepatic multislice CT using a dual-head power injector. One hundred twenty-one patients who underwent multislice CT to detect liver metastases were divided into two groups, depending on the protocol of contrast material administration: 100 mL of non-ionic contrast material (370 mgI/mL) or 100 mL of the same contrast material pushed with 30 mL of saline solution. Both contrast material and saline solution were administered at a rate of 2.5 mL/sec using a dual-head power injector. Attenuation values for the two protocols were obtained from the liver, portal vein, and descending aorta. Hepatic enhancement above 50 Hounsfield unit (HU), which is needed for the diagnosis of liver metastases, was achieved in 76.5% of patients given 100 mL of contrast material and 92.5% of those given 100 mL of contrast material pushed with a 30 mL saline solution. In contingency-table analysis, the CT attenuation value of liver categorized as less than 50 HU or more than 50 HU, showed a good relation between the categorized group and the protocol (p=0.0437). In patients with a body weight of 50 kg or more, 100 mL of contrast material pushed with saline solution provided significantly better CT attenuation values in the liver (p=0.0113), portal vein (p=0.0094), and descending aorta (p=0.0394) than those provided by the injection of 100 mL of contrast material alone. When contrast material pushed with saline solution was used, CT attenuation values in the liver were significantly increased, especially in patients with a body weight of 50 kg or more. This technique will provide a decrease in the volume of contrast material administered and a potential decrease in the side effects of contrast material. (author)

  14. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A. [University Hospital, Department of Radiology, Freiburg im Breisgau (Germany); Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P. [University Hospital, Department of Orthopaedic and Trauma Surgery, Freiburg im Breisgau (Germany); Uhl, Markus [University Hospital, Department of Radiology, Section of Paediatric Radiology, Freiburg im Breisgau (Germany)

    2009-03-15

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  15. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    Science.gov (United States)

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  16. The diagnostic value of multi-slice CT on the congenital malformation of coronary sinus

    International Nuclear Information System (INIS)

    Li Wei; Ma Xiaojing; Sun Qingjun

    2012-01-01

    Objective: To investigate the application value of multi-slice spiral CT on the congenital malformation of coronary sinus. Methods: MSCT finding of 98 patients with coronary sinus malformation confirmed by surgery were retrospectively analyzed,and the cases were divided into four categories based on the Mantini theory and comparison was made between the diagnosis from ultrasound and CT. A 2 × 2 table for Chi-square test was also used for statistics analysis. Results: Among 98 patients,there were 72 patients with persistent left superior vena cava reflowed to right atria through coronary sinus, with 48 patients diagnosed by ultrasound and 72 patients by MSCT; there were 13 patients with anomalous pulmonary venous connection to coronary sinus, with 12 patients diagnosed by ultrasound and 13 patients by MSCT diagnosis; there were 10 patients with unroofed coronary sinus syndrome, with 6 patients diagnosed by ultrasound and 8 patients by MSCT, there were 2 patients with coronary sinus atresia, all diagnosed by MSCT; there were 1 patient with coronary sinus anomaly reflow to left arita. The significant difference between 2 modalities (χ 2 =22.7, P<0.01) shows that CT is superior to ultrasound. Conclusion: MSCT is much more better than ultrasound in the diagnosis of malformation of coronary sinus and it can provide reliable diagnosis prior to surgery or interventional therapy. (authors)

  17. Multislice CT of the auditory ossicles and ossicular ligaments. Delineation of normal anatomy and diagnosis of congenital anomaly

    International Nuclear Information System (INIS)

    Matsumoto, Shigeru; Tozaki, Hiromitu; Miyazaki, Hidemi

    2001-01-01

    By using four detector rows with 0.5 mm collimation, high resolution isotropic voxel data throughout the middle ear can be obtained with Multislice Helical CT (MSCT). The purpose of this study is to evaluate the usefulness of MSCT in demonstrating the auditory ossicles and ossicular ligaments and in the diagnosis of congenital ossicular anomalies. Thirty normal middle ears and 23 ear of 20 patients with suspicious congenital ossicular anomalies were examined. Axial images and multiplanar images were reconstructed. In the normal group, the images were evaluated based on scores for the visualization of the anatomical structure of the auditory ossicles and ossicular ligaments. In the group with anomalies, the findings suggesting ossicular anomalies were referenced and the prevalence was conjectured. Visualization of the auditory ossicles and ossicular ligaments was 98.3%-100% and 78.3%-100%, respectively. Congenital ossicular anomalies were detected in 20 ears (87.0%). MSCT is an accurate method for demonstrating minute and complicated 3D structures of the middle ear, and is found to be a technique of choice for diagnosis of ossicular anomalies. (author)

  18. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  19. Clinical application of multi-slice helical CT volumetric scanning in lumber spine

    International Nuclear Information System (INIS)

    Wang Ling; Ge Yinghui; Zhu Shaocheng; Zhang Ming; Cheng Tianming; Lei Zhidan; Lv Chuanjian; Sun Xiaoping; Wu Minghui; Guo Ying; Ma Qianli; Wen Zeying

    2008-01-01

    Objective: To evaluate the clinical application value of multi-slice helical CT volumetric (VH) scanning in lumber spine. Methods: One thousand of patients with back and leg pain who underwent CT examinations were selected as subjects. We simulated the traditional protocol of single-slice(SS) discrete scanning for L3/4, L4/5, and L5/S1 intervertebral discs. The VH scanning mode was performed with 120 kV, 210 mAs, pitch of 1.5 and coverage of 97.5 mm. The simulated SS scanning mode was performed with 120 kV, 240 mAs and coverage of 45.0 mm. The diagnostic outcomes and the radiation doses were compared between the two scanning modes. Two groups doctors observed ten terms, including the osseous spinal stenosis, narrowed intervertebral space and so on in two scanning modes respectively. Then consistency analysis of the data was carded out. Results: The VH scanning mode showed far more features than the SS mode. The detection rates of the VH mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, narrowed lateral recess, vertebral lesion, hypertrophy of L5 transverse process, abnormal direction of facet, facet degeneration, lumbar spondyloschisis, and paraspinal soft tissue were 11.8% (n=118), 38.5% (n=385), 9.3% (n=93), 46.8% (n=468), 31.4% (n=314), 5.7% (n= 57), 25.4% (n=254), 49.7% (n=497), 9.9% (n=99), and 0.6% (n=6) respectively, while the detection rates of the SS mode in ten terms were 5.6% (n=56), 0, 0.6% (n=6), 27.9% (n=279), 22.4% (n=224), 1.2% (n=12), 16.7% (n=167), 37.2% (n=372), 0.5% (n=5), and 0.2% (n=2) respectively. The difference between the two groups had statistically significance (average P 0.05). The detection rates of the VH mode were higher than the SS mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, lumbar spondyloschisis, being 6.2% (n=62), 38.5% (n=385), 8.7% (n=87), and 9.4% (n=94), respectively. In addition, VH mode only partially showed the articular

  20. Low-dose multi-slice CT (LMCT) assessment of pulmonary emphysema in public-school teachers

    International Nuclear Information System (INIS)

    Horiuchi, Noriaki; Yamazaki, Yasuhiro; Fujita, Jiro; Suemitsu, Ichizou; Kamei, Tadashi; Tada, Shinya; Ueda, Nobuo

    2003-01-01

    Although rates of emphysematous change in smokers have been reported previously, the precise effects of smoking on emphysematous change have not been established because the study subjects of previous reports were heterogeneous. This study was designed to determine the incidence of emphysematous change identified by low-dose multi-slice CT (LMCT) imaging in public-school teachers. We reviewed 1776 consecutive subjects (ages from 31 to 61 years) who had undergone LMCT scanning during health care examinations. In addition, their replies to questionnaires about smoking were obtained. Emphysematous change was found by LMCT imaging in 22 male smokers. In these 22 smokers, the scores of emphysematous change according to Goddard's method was well correlated with smoking history. According to the questionnaires, the smoking rates of male and female teachers were 56.7% and 4%, respectively. Eighty-five percent of the teachers worked in offices separated from smokers. Most smokers wished to quit smoking and most teachers knew the risk of nicotine as well as the rate of smoking among high school students. However, knowledge of the relationships between smoking and lung cancer, myocardial infarction, and subarachnoid hemorrhage were not adequate. Our present study clearly demonstrated the incidence of emphysematous change in school teachers. In addition, early exposure to information about the risks of smoking is believed to be important for students, but school teachers did not have enough of such information. (author)

  1. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  2. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  3. The value of multislice spiral CT in transcatheter arterial chemoembolization of the hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Li Zhigang; Zhao Junjing; Shi Gaofeng; Li Shunzong; Han Pengyin; Yang Guang; Liang Guoqing; Wang Hongguang; Huang Jingxiang

    2006-01-01

    Objective: To evaluate the value of multislice spiral CT (MSCT) in transcatheter arterial chemoembolization of the hepatocellular carcinoma. Methods: MSCT were performed in 54 cases of HCC before interventional procedure. CT findings of hepatic artery phase, portal venous phase and hepatic venous phase were observed respectively. CTA were done in 12 cases, the anatomy of celiac artery and its branches were observed. The schemes of interventional therapy were worked out according to the findings of MSCT. The demonstration of lesions and its complications were compared between CT and DSA. Reconstruction of celiac artery branches used the technique of VRT, MIP or MPR. Results: MSCT showed 225 lesions, 10 cases tumor thrombosis of portal vein, 1 case hepatic arteriovenous shunt, and 13 cases hepatic arterioportal shunt. Positive rate of MSCT in showing number of tumor lesions, tumor thrombosis in portal vein was slightly higher than that of DSA, but there was no significant difference (P>0.05). Showing of 3D reconstruction of celiac artery branches in CTA is better than that in DSA, Showing of angles between celiac artery and abdominal aorta in MSCT is more convenient than that in DSA. MSCT showed 5 cases hepatic artery original abnormality. The results were in accord with that in DSA. Five cases were demonstrated of multiple supply blood vessels of tumor in MSCT, It was slightly lower than that of DSA. Conclusion: MSCT is of importance for guidance of transcatheter arterial chemoembolization of the hepatocellular carcinoma, delay time of CT scan is the key to the showing of lesions and blood vessels. (authors)

  4. Multislice CT coronary angiography: how to do it and what is the current clinical performance?

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Runza, Giuseppe; Schuijf, Joanne D.; Mollet, Nico R.; Feyter, Pim J. de; Malagutti, Patrizia; Bax, Jeroen J.

    2005-01-01

    The introduction of multislice computed tomography (MSCT) has allowed non-invasive coronary angiography. Although widely applied, extensive information on technical details of the technique is lacking. This survey offers detailed information on patient preparation, data acquisition, reconstruction and interpretation. In addition, a summary of the available studies using MSCT for non-invasive angiography is provided. Based on pooled analysis of direct comparisons between MSCT and invasive angiography, the weighted mean sensitivity and specificity of current 16-slice MSCT for the detection of coronary artery disease are 88% and 96%, respectively. At present, the technique is particularly well suited for reliable exclusion of coronary artery disease. It is important to emphasise that MSCT only provides anatomical images, visualising the presence of atherosclerosis; information on the haemodynamic significance of these lesions (i.e. ischaemia) cannot be derived. (orig.)

  5. Approximations of noise covariance in multi-slice helical CT scans: impact on lung nodule size estimation.

    Science.gov (United States)

    Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J

    2011-10-07

    Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.

  6. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  7. [Diagnostic significance of multi-slice computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Liu, Fang; Tian, Zhi-Liang; Lei, Zi-Qiao; Li, You-Lin; Kong, Wei-Jia

    2005-04-01

    To evaluate the feasibility and usability of multi-slice computed tomography (MSCT) in congenital inner ear malformations. Fourty-four patients with sensorineural hearing loss (SNHL) were examined by a Somatom Sensation 16 (siemens, Germany) CT scanner with following parameters: 120 kV, 100 mAs, 0.75 mm collimation, 1 mm reconstruction increment, a pitch factor of 1 and a field of view of 100 mm. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment, and a field of view of 50 mm. The 3D reconstructions were done with volume rendering technique (VRT) on the workstation (3D Virtuoso and Wizard,siemens). Twenty-five patients were normal and 19 patients (36 ears) were congenital inner ear malformations among 44 patients scanned with MSCT. Of the malformations, all the axial, MPR and VRT images can display the site and degree in 33 ears. VRT images were superior to the axial images in displaying the malformations in 3 ears with the small lateral semicircular canal malformations. The malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity, 5 ears), vestibular and semicircular canal malformations( 14 ears), vestibular aqueduct dilate( 16 ears, of which 6 ears accompanied by other malformations), the internal auditory canal malformation(8 ears, all accompanied by other malformations). MSCT allows a comprehensively assessing various congenital ear malformations through high quality MPR and VRT reconstructions. VRT images can display the site and degree of the malformations three-dimensionally and intuitionisticly. It is very useful to the cochlear implantation.

  8. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  9. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    Energy Technology Data Exchange (ETDEWEB)

    Teksam, Mehmet E-mail: mehmetteksam@yahoo.com; McKinney, Alexander; Truwit, Charles L

    2004-12-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass.

  10. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    International Nuclear Information System (INIS)

    Teksam, Mehmet; McKinney, Alexander; Truwit, Charles L.

    2004-01-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass

  11. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas H.; Katoh, Markus; Guenther, Rolf W.; Wildberger, Joachim E.; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Gietema, H.A.; Prokop, Mathias; Czech, Andre; Diederich, Stefan; Bakai, Annemarie; Salganicoff, Marcos

    2007-01-01

    The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm 3 -525 mm 3 ), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (±7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (±11.1%) for the GE scanner, 9.7% (±9.6%) for the Philips scanner and 7.5% (±7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm 3 . Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies. (orig.)

  12. 64 multislice computed tomography imaging of coronary artery origin anomalies in adults

    International Nuclear Information System (INIS)

    Dai Qinyi; Lv Biao; Zhang Zhaoqi

    2006-01-01

    Objective: To assess the value of 64 multislice computed tomography (64 MSCT) in the evaluation of coronary artery origin anomalies in adults. Methods: Nine hundred and seventy eight Chinese adult patients undergone coronary artery CT angiography (CTA) between March and July 2005 at Anzhen hospital were reviewed for this study. Results: In consecutive 978 patients, 64 MSCT identified (3.07%) with an anomalous origin of the coronary artery, in 30 patients including anomalous origin of the right coronary artery (RCA) in 9 patients, the left coronary artery (LCA)in 7 patients, both RCA and LCA in 2 patients, the absence of the left circumflex artery (LCX) in 1 patient and anomalous origin of the branch of coronary artery in 11 patients. Conclusion: Noninvasive 64 multislice computed tomography can detect the anomalous origin of the coronary artery with high resolution. (authors)

  13. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  14. Visualization of brain surface structures by weighted summation technique using multislice MR images

    International Nuclear Information System (INIS)

    Machida, Yoshio; Hatanaka, Masahiko; Hagiwara, Masayuki; Sugimoto, Hiroshi; Yoshida, Tadatoki; Katada, Kazuhiro.

    1991-01-01

    Surface anatomy scanning (SAS) technique which visualizes brain surface structures has been developed since 1987. In this paper, we propose a modified method called 'multislice SAS', which also generates such surface structure images, and has several advantages compared with conventional SAS technique. The conventional SAS technique uses a very long echo time sequence (e.g. SE(3000, 250)) with a thick slice and a surface coil to enhance CSF on the brain surface. Our modified technique also uses a long echo time sequence. But, added multislice images, each appropriately weighted, are used in stead of a thick slice and a surface coil. Our basic studies have shown that this modified method has the following advantage: Several surface images with slightly different summation directions are obtained, and they are used for stereographic display and cine display. This is very useful for visualizing the spatial relationship of brain surface structures. By choosing appropriate weighting, we can obtain clinically legible surface images. This technique dose not require a surface coil. It means that flexibility of selecting imaging direction is high. We can make a lot of modifications, because the original multislice images of weighted summation are arbitrary. And we also clarify some limitation or disadvantage of this modified method. In conclusion, we think that this technique is one of the practical approaches for surface anatomy imaging. (author)

  15. Evaluation of the nutcracker syndrome using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Fan Yanqing; Han Ping; Zhou Chengkai; Zhao Long; Wu Hongying; Yu Qun; Liu Yonghua

    2007-01-01

    Objective: To evaluate the ability of multi-slice spiral CT (MSCT) in diagnosing nutcracker syndrome(NCS). Methods: MSCT angiography (MSCTA) or contrast enhanced CT data of 16 patients clinically diagnosed as NCS( patient group) and 80 subjects with nomal kidneys and renal vessels (control group ) were retrospectively reviewed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The angle (a) between SMA and the abdominal aorta (AA), the distance (d) between SMA and AA at the level of LRV passing through, the cross areas of LRV through the angle (s1) and at the largest diameter near the renal hilar (s2) were measured and the ratio(q) of s2 to sl was calculated. Results: All LRVs were compressed and showed dilated, 7 of them with the genesial gland vein enlargement. The causes of the LRV narrowing and obstruction were small angle (a) in 14 patients and abnormal path of LRV posterior to AA in 2 cases. The value of a,d,s1,s2 and q in the patient group and the control group were: (21±4) degree, (0.53±0.11) cm, (0.28±0.06) cm 2 , (1.42±0.48) cm 2 , 5.26 and (52±24) degree, (1.39±0.70) cm, (0.81±0.32) cm 2 , (1.21±0.35) cm 2 , 1.52, respectively. The differences were significant between the two groups (P< 0.05). Conclusion: The appearance and its path of the LRV could be well delineated on the MSCT, allowing a accurate evaluation of the LRV narrowing non-invasively. (authors)

  16. Study of the usefulness of large intestine screening inspections using multi-slice CT (MSCT)

    International Nuclear Information System (INIS)

    Yamasaki, Michihiro; Nonogaki, Hidehiko; Hara, Koji; Naruse, Yutaka; Hara, Hiroto; Suematsu, Seiji; Yanase, Tadahiko; Otou, Taiji

    2005-01-01

    CT-colonography (CT-C), a new diagnostic imaging technique for cancer of the large intestine-which is increasing rapidly owing to westernized eating habits-has advanced from the developmental stage to the stage of practical application, thanks to progress in MSCT and workstation development. Therefore, based on the results of CT-C application using 16 lines of MSCT to a screening test, we reviewed the usefulness of CT-C in our clinic. We supplemented defective depiction, and found that change of position was effective for virtual image exclusion. We consider that CT-C can support diagnosis if the target of screening tests is a polypoid lesion of more than 6 mm. In addition, it is expected that the number of examinations performed during office visits will increase because of the decreased invasiveness of the procedure, its lack of pain, and its ability to provide early lesion detection. (author)

  17. Multislice Helical CT Angiography in Diagnostic of Intracranial and Extracranial Arterial Dissection

    International Nuclear Information System (INIS)

    Radzina, M.; Krumina, G.; Pupols, J.

    2007-01-01

    Arterial dissection is detachment of inner layer of the vessel wall. Head-neck trauma, congenital connectives tissue disorders like fibromuscular dysplasia, infectious diseases, hypertension, migraine, alcohol abuse and oral contraception are the typical causes. Urgent, complete, detailed verification is essential for successful treatment decision. Purpose. Aim of the study was to develop new appropriate CTA (angiography) protocols for patients with intracranial and extracranial arterial dissections using high speed multislice CT; to evaluate its clinical value in different locations and stages of disease, perspectives, advantages and disadvantages of new method. Materials and methods. 30 adult patients with suspected intra- or extracranial arterial blood vessels dissections were investigated in the clinical hospital 'Gailezers' using following algorithm: native CT; contrast CTA with post processing on the workstation. 80 ml iodine contrast media was administered intravenously, line speed 3-4 ml/sec, delay 10-15 seconds. For detection of maximum contrast intensity in the vessel the test contrast injection was performed before. Primary scan series were post processed in different kind of reconstructions - MPR (Multiplanar Reconstructions), MIP (Maximal Intensity Projection), VR (Volume Rendering), CR (Curved Reformat) and vessel analysis. Two different types of protocols were used - for intracranial and brachiocefalic arteries examinations. Results and Discussion. Following CTA symptoms of dissection were verified: 1) irregular vessel contour changes - narrowing, 'string' sign above dissection level; 2) tapered stenosis and/or distal occlusion; 3) double contour and/or double lumen sign; 4) fusiform aneurysmal dilatation. Clinical cases of different arterial dissection localization will be demonstrated during the presentation Advantages and disadvantages of CTA will be presented and disputed. Conclusions. CTA is non-invasive radiologic diagnostic method that yields

  18. Mapping the extent of disease by multislice computed tomography, magnetic resonance imaging and sentinel node evaluation in stage I and II cervical carcinoma

    Directory of Open Access Journals (Sweden)

    Rajaram S

    2010-01-01

    Full Text Available Aims: (1 To map the extent of disease in women with stage I and II carcinoma cervix by multislice spiral computed tomography (CT, magnetic resonance imaging (MRI and sentinel nodes. (2 To assess accuracy of each modality individually and in conjunction with FIGO clinical staging. Design and Setting: Prospective, single-blind study. Departments of Obstetrics and Gynaecology, Radiodiagnosis, and Pathology, UCMS and GTBH and Division of Radiological Imaging and Bioinformatics, INMAS, Delhi. Material and Method: The study was conducted on 25 women with cervical cancer FIGO stage I and II. Each woman underwent clinical staging, multislice spiral CT and MRI which was compared to the gold-standard histopathology/cytology. The overall accuracy of each modality and improvement of clinical staging by CT/MRI were noted. Sentinel nodes were evaluated by intracervical Patent Blue V dye injection. Statistical Analysis: Sensitivity, specificity, positive and negative predictive values were calculated by 2Χ2 contingency tables. Results: The accuracy of staging by FIGO, CT and MRI was 68%, 52% and 80%, respectively. MRI and CT improved the overall accuracy of FIGO staging to 96% and 80%, respectively. Sentinel nodes were identified in 89% of patients with 91% accuracy. Conclusion: MRI emerges as the most valuable stand-alone modality improving accuracy of FIGO staging to 96%. Sentinel lymph-node evaluation appears promising in evaluating spread beyond cervix.

  19. Accuracy of liver lesion assessment using automated measurement and segmentation software in biphasic multislice CT (MSCT)

    International Nuclear Information System (INIS)

    Puesken, M.; Juergens, K.U.; Edenfeld, A.; Buerke, B.; Seifarth, H.; Beyer, F.; Heindel, W.; Wessling, J.; Suehling, M.; Osada, N.

    2009-01-01

    Purpose: To assess the accuracy of liver lesion measurement using automated measurement and segmentation software depending on the vascularization level. Materials and Methods: Arterial and portal venous phase multislice CT (MSCT) was performed for 58 patients. 94 liver lesions were evaluated and classified according to vascularity (hypervascular: 13 hepatocellular carcinomas, 20 hemangiomas; hypovascular: 31 metastases, 3 lymphomas, 4 abscesses; liquid: 23 cysts). The RECIST diameter and volume were obtained using automated measurement and segmentation software and compared to corresponding measurements derived visually by two experienced radiologists as a reference standard. Statistical analysis was performed using the Wilcoxon test and concordance correlation coefficients. Results: Automated measurements revealed no significant difference between the arterial and portal venous phase in hypovascular (mean RECIST diameter: 31.4 vs. 30.2 mm; p = 0.65; κ = 0.875) and liquid lesions (20.4 vs. 20.1 mm; p = 0.1; κ = 0.996). The RECIST diameter and volume of hypervascular lesions were significantly underestimated in the portal venous phase as compared to the arterial phase (30.3 vs. 26.9 mm, p = 0.007, κ 0.834; 10.7 vs. 7.9 ml, p = 0.0045, κ = 0.752). Automated measurements for hypovascular and liquid lesions in the arterial and portal venous phase were concordant to the reference standard. Hypervascular lesion measurements were in line with the reference standard for the arterial phase (30.3 vs. 32.2 mm, p 0.66, κ = 0.754), but revealed a significant difference for the portal venous phase (26.9 vs. 32.1 mm; p = 0.041; κ = 0.606). (orig.)

  20. Application of the FDK algorithm for multi-slice tomographic image reconstruction; Aplicacao do algoritmo FDK para a reconstrucao de imagens tomograficas multicortes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto, E-mail: pcosta@if.usp.b [Universidade de Sao Paulo (IFUSP), SP (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear; Araujo, Ericky Caldas de Almeida [Fine Image Technology, Sao Paulo, SP (Brazil)

    2010-08-15

    This work consisted on the study and application of the FDK (Feldkamp- Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an X-ray equipment and a digital image detector charge-coupled device type were used. The FDK algorithm was implemented on a computer with a Pentium{sup R} XEON{sup TM} 3.0 processor, which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution ({mu}(r)) was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose distribution {mu}(r) was unknown. Some aspects of the reconstructed images were analyzed to assess the robustness and reproducibility of the system. During the system calibration, a linear relationship between CT number and linear attenuation coefficients of materials was verified, which validate the application of the implemented multi-slice tomographic system for the characterization of linear attenuation coefficients of distinct several objects. (author)

  1. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT.

    Science.gov (United States)

    Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde

    The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except

  2. Multislice helical CT analysis of small-sized airway wall thickness in smokers and patients with bronchial asthma

    International Nuclear Information System (INIS)

    Sekimura, Kenshi; Ito, Harumasa; Nakamura, Yutaka; Kobayashi, Hitoshi; Oikawa, Hirobumi; Inoue, Hiroshi; Ehara, Shigeru; Yamauchi, Kohei

    2010-01-01

    There is accumulating evidence that airway remodeling, which contributes to airway narrowing, plays a role in the pathogenesis of bronchial asthma (BA) and chronic obstructive pulmonary disease (COPD). Development of the multislice helical CT (MSCT) with improved spatial resolution has made it possible to obtain more precise imaging of small-sized airways. Small-sized airway wall-thickness was measured using the MSCT scan to analyze small-sized airways of smokers and BA patients, and examine the effects of a β 2 agonists on small-sized airway wall-thickness of BA patients. Thirty-six non-asthmatics who participated in the Health Check Program of Iwate Medical University and 25 patients with asthma were recruited. Amongst the 36 non-asthmatics were 20 healthy never-smokers and 15 smokers. The other 25 asthmatics were recruited from the outpatient clinic at Iwate Medical University. MSCT was performed and the right B10 bronchus was chosen for dimensional analysis. Airway wall thickness was expressed as a percentage of wall area (WA%). WA% of the 7 asthmatics before and 30 mim after procaterol (20μg) inspiration were compared. Small-sized airway wall thickness was significantly increased in smokers and patients with asthma compared to healthy never-smokers, when determined by MSCT. Both %V 50 and %V 25 had significant negative correlations with WA% among the healthy never-smokers and smoker population. Procaterol inspiration reduced WA% in the small airway of patients with asthma. Increase of small-sized airway thickness measured by MSCT scan may reflect peripheral obstructive lesions of smokers and BA patients. (author)

  3. Primary study of quantitative measurement in different grades of COPD using low-dose multislice CT

    International Nuclear Information System (INIS)

    Li Yiming; Yin Jianzhong; Yang Wenjie; Tan Zhengshuai

    2012-01-01

    Objective: To study the feasibility of airway measurement at the trunk of apical bronchus of right upper lobe in chronic obstructive pulmonary disease (COPD), and airway dimensions and lung density changes in different COPD stages. Methods: 1) Fifteen randomly selected COPD patients underwent low -dose chest multi -slice CT scan. The wall thickness-to-diameter ratio (TDR) and percentage wall area (WA%) at apical bronchus of right upper lobe section and mean TDR and WA% of small airway (<2 mm) were calculated. 2) Another fifty-five randomly selected COPD patients were divided into 4 groups on the basis of pulmonary function tests. There were sixteen patients with grade 1, sixteen patients with grade 2, fourteen patients with grade 3. and nine patients with grade 4. Fifteen non-COPD patients were selected as controls. The total lung was scanned with low-dose multi-slice CT during inspiration. The mean lung attenuation (MLA) and voxel index (VI) were measured. Inner area of bronchus (A i ), TDR and WA% of the apical bronchus of right upper lobe were measured. Results: 1) The TDR of the apical bronchus of right were smaller than the mean TDR of the small airways; The WA% of the apical bronchus of right were larger than the mean WA% of the small airways; but there were good correlation (r=0.793 and 0.784, respectively). 2) The MLA values were decreased with increase of COPD stage. The VI values were increased with increase of COPD stage. However, the values did not differ between adjacent stages. The luminal areas of stage 3-4 patients were smaller than that of other stages. There was no statistics difference in TDR between adjacent groups, except between stages 3 and 4. For WA%, the higher stage group had higher WA%. Conclusion: There were good correlations for TDR and WA% between the apical bronchus of right upper lobe and small airway. WA% is the most sensitive index for detecting thickened airway. (authors)

  4. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  5. Correlation of Multislice CT and Histomorphology in HCC Following TACE: Predictors of Outcome

    International Nuclear Information System (INIS)

    Herber, S.; Biesterfeld, S.; Franz, U.; Schneider, J.; Thies, J.; Schuchmann, M.; Dueber, C.; Pitton, M. B.; Otto, G.

    2008-01-01

    The purpose of this study was to correlate histopathological with CT findings in patients suffering from hepatocellular carcinoma (HCC) eligible for orthotopic liver transplantation (OLT), with a special focus on the antitumoral effect of transarterial chemoembolization (TACE) therapy. A total of 42 consecutive patients suffering from HCC had been treated prior to OLT by means of TACE. TACE was carried out with a mixture of Lipiodol (10-20 ml) and mitomycin C (max. dosage, 10 mg). TACE was performed at 6- to 8-week intervals. Follow-up investigation included contrast-enhanced multislice CT controls and laboratory control. Liver explants were evaluated macroscopically and microscopically to determine the number and size of the tumor lesions as well as the degree of tumor necrosis. Necrosis was investigated in H and E-stained sections. The degree of necrosis was classified as follows: 0-25%, 26-50%, 51-75%, 75-99%, and complete necrosis. Two hundred thirty-one TACE procedures (5.5 ± 2.9; range, 1-14) were performed. Mean tumor size in CT before and after TACE was 4.1 ± 2.4 (range, 1.0-12.0 cm) and 2.7 ± 1.2 (range, 1.0-6.0 cm; p < 0.001). Mean tumor number before and after TACE in CT was 2.5 ± 1.5 (n = 105; range, 1-8) and 2.4 ± 2.0 (n = 103; range, 1-6; p = 0.99). In the surgical specimen tumor size and tumor number were 2.8 ± 1.6 (range, 1.0-7.0 cm; p = 0.78) and 1.9 ± 1.2 (range, 1-7; p = 0.003). Mean tumor necrosis was 67.8% ± 28.1%. Tumor necrosis was subtotal or complete in 17 of 42 (40.5%) patients. Tumor necrosis correlated significantly with the degree of arterial devascularization in CT (p = 0.001), the amount of Lipiodol washout (p = 0.002), and the number of tumor lesions (i.e., unifocal vs. multifocal). Furthermore, elevated serum levels of bilirubin (p = 0.005) and decreased albumin (p = 0.004) affected the local antitumoral effect. A poor necrosis rate (< 25%) significantly correlated with the number of TACE procedures accomplished (p = 0

  6. Evaluation of endometrial carcinoma by multislice dynamic MR imaging with Turbo FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Mari [Okayama Univ. (Japan). School of Medicine

    1995-04-01

    The purpose of this study was to investigate the usefulness of multislice dynamic MR imaging with Turbo FLASH in assessing myometrial invasion by endometrial carcinoma. Dynamic MR imaging was performed with bolus injection of Gd-DTPA and with 1.5-T Siemens Magnetom imager using Turbo FLASH. Thirty-six endometrial carcinomas were evaluated with pathologic correlation. Junctional zone showed more rapid contrast enhancement effects than myometrium even after menopause. Contrast to noise ratio between junctional zone and endometrial carcinoma was the highest about fifty seconds after bolus injection. Only at that time could the degree of invasion to junctional zone in post-menopausal women whose junctional zones could not be seen on T{sub 2}-weighted images or contrast-enhanced T{sub 1}-weighted images be evaluated correctly. The accuracy in assessing myometrial invasion with T{sub 2}-weighted images, postcontrast T{sub 1}-weighted images, and dynamic MR imaging was 75%, 81% and 89% respectively. Though there was no statistically significant difference, multislice dynamic imaging with Turbo FLASH technique is considered to be a useful imaging method for the pre-operative assessment of myometrial invasion by endometrial carcinoma. (author).

  7. CT imaging features of anaplastic thyroid carcinoma

    International Nuclear Information System (INIS)

    Shi Zhenshan; You Ruixiong; Cao Dairong; Li Yueming; Zhuang Qian

    2013-01-01

    Objective: To investigate the CT characteristics of anaplastic thyroid carcinoma and evaluate the diagnostic value of CT in this disease. Methods: The CT findings of 10 patients with pathologically proved anaplastic thyroid carcinoma were retrospectively reviewed. The patients included 7 females and 3 males. Their age ranged from 25.0 to 78 years with median of 61 years. Multi-slices plain and post contrast CT scans were performed in all patients. Results: Unilateral thyroid was involved in 6 patients. Unilateral thyroid and thyroid isthmus were both involved in 2 patients due to big size. Bilateral thyroid were involved in 2 patients. The maximum diameter of anaplastic thyroid carcinoma ranged from 2.9-12.8 cm with mean of (4.5 ± 1.4) cm. All lesions demonstrated unclear margins and envelope invasion. The densities of all lesions were heterogeneous and obvious necrosis areas were noted on precontrast images. Seven lesions showed varied calcifications, and coarse granular calcifications were found in 5 lesions among them. All lesions showed remarkable heterogenous enhancement on post-contrast CT. The CT value of solid portion of the tumor increased 40 HU after contrast media administration. The ratios of CT value which comparing of the tumor with contralateral sternocleidomastoid muscle were 0.69-0.82 (0.76 ± 0.18) and 1.25-1.41 (1.33 ± 0.28) on pre and post CT, respectively. Enlarged cervical lymph nodes were found in 6 cases (60.0%). It showed obvious homogeneous enhancement or irregular ring-like enhancement on post-contrast images and dot calcifications were seen in 1 case. Conclusions: Relative larger single thyroid masses with coarse granular calcifications, necrosis,envelope invasion, remarkable heterogeneous enhancing and enlarged lymph nodes on CT are suggestive of anaplastic thyroid carcinoma. (authors)

  8. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction; Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter

    Energy Technology Data Exchange (ETDEWEB)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E. [Abt. Roentgendiagnostik I, Georg-August-Univ. Goettingen (Germany); Merten, H.A. [Abt. fuer Mund-, Kiefer- und Gesichtschirurgie, Georg-August-Univ. Goettingen (Germany)

    2002-07-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [German] Zielsetzung: Verbesserung der Aufnahme- und Rekonstruktionsparameter in der Mehrschicht Spiral-CT (MSCT) zur Untersuchung des knoechernen Mittelgesichtes in verschiedenen Ebenen. Material und Methode: Ein anthropomorphes Schaedel-Phantom wurde in axialer Schichtfuehrung mit einem MSCT untersucht, wobei die Kollimation (1,25 - 2,5 mm), der Tischvorschubfaktor (Pitch 3 - 6) und der Roehrenstrom (20 - 200 mA) systematisch variiert wurden. Aus den Volumendatensaetzen wurden jeweils koronare und parasagittale Sekundaerreformationen mit unterschiedlichen

  9. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    OpenAIRE

    Livingstone Roshan; Pradip Joe; Dinakran Paul; Srikanth B

    2010-01-01

    Objective: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tu...

  10. The investigation of the lateral atlanto-dental interval of atlanto-axial joint by multi-slice spiral CT

    International Nuclear Information System (INIS)

    Cui Wei; Peng Lei; Wang Jincai; Liu Jihua; Feng Weihua

    2010-01-01

    Objective: To explore imaging features of the lateral atlanto-dental interval (LADI) of atlanto-axial joint and its value in the diagnosis of atlanto-axial joint dislocation/subluxation. Methods: Two hundred and forty healthy volunteers without atlanto-axial joint dysfunction and 32 patients with torticollis and/or functional impairment at atlanto-axial.joint were enrolled into this study. All subjects were examined with multi-slice CT in both neutral and max rotation positions to the left/right. Clinical endpoints including VBLADI, variance range of the VBLADI and asymmetric conditions were evaluate. χ 2 test is used to evaluate the variance of incidence of bilateral LADI asymmetry in different age groups, Pearson-test (2-tailed) is used to evaluate the correlation between VBLADI and rotary function of atlanto-axial joint, precise test of fourfold table is used to compare normal group with patient groups. Results: (1) In the normal control group: asymmetry of bilateral LADI were observed in 204 among 240 (85.00%) healthy volunteers including 60 youngsters ( 95% of ∣ VBLADI ∣ were 0.850 mm, 2.450 mm in the young ( 95% in the young and in the adult respectively. There was no correlation between VBLADI(-2.146 to 2.114 mm, Median 0.000 mm) and LA (22.949° to 44.649°, Median 34.500°), RA (25.284° to 45.334°, Median 35.300°), VLRA (-11.643° to 8.623°, median 0.000°) respectively in normal people (r=-0.030, -0.005, 0.026, P>0.05). (2) In the study with 32 patients including 25 youngsters ( 95% in group AALSD and group AACD than in abnormal group (P<0.01), but there is no difference between group AARD and normal group (P=0.738). Conclusion: The imaging finding of 'asymmetry of bilateral LADI' may be either a physiological variation or a pathological condition, clinical manifestations and other imaging findings should be evaluated to make a diagnosis. (authors)

  11. Value of multi-slice spiral CT in diagnosis the detection of fish bone impaction in the esophagus

    International Nuclear Information System (INIS)

    Luo Min; Hu Daoyu; Wang Qiuxia; Pei Yigang

    2009-01-01

    Objective: To investigate the detection rate and diagnostic value of multi-slice spiral CT scan in detecting fish bone impaction in the esophagus. Methods: Experimental group: 30 fresh water fish bones from three variety classes were divided into three groups with length of (23.36±0.15), (28.51± 0.07) and (30.89±0.10) mm, and diameter of (4.49±0.31), (1.78±0.09) and (0.49±0.07) mm. The fish bones were put into esophagus models in three different types including parallel, perpendicular and oblique. MSCT with axial scan combined with three dimensional reconstruction technique and plain X-ray film ( CR and DR) were used to examine the model. The relations of the number and rate of fish bones were compared between MSCT and X-ray film. Clinical group: MSCT imaging were performed in 20 cases proved by esophageal endoscope or clinical operation, among which 11 cases received plain X-ray film (CR and DR), 15 cases received Barium-soaked cotton and 17 cases received endoscope. Paired Chi-square test was used to compare the differences of detection of fishbone by the different ways. Results: In experimental group: All the 90 cases (100%) fish bones of three different species were clearly revealed on MSCT image; only 60 cases (66.7%) fish bones were revealed by plain X-ray film (CR and DR). The number and rate of fish bones detected by MSCT was higher than that of plain X-ray film (CR and DR) (χ 2 =28.03, P 2 =7.11, P 2 =4.17, P<0.05). Conclusions: The sensitivity and detection rate of fish bone with MSCT was high and could evaluate the surrounding and complications of the esophagus. MSCT could be used as the first examination of impacted fish bones in the esophagus. (authors)

  12. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Watzke, Oliver; Kalender, Willi A.

    2001-01-01

    In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region

  13. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun

    2013-12-01

    Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.

  14. Segmentation algorithm of colon based on multi-slice CT colonography

    Science.gov (United States)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  15. Dual source CT imaging

    International Nuclear Information System (INIS)

    Seidensticker, Peter R.; Hofmann, Lars K.

    2008-01-01

    The introduction of Dual Source Computed Tomography (DSCT) in 2005 was an evolutionary leap in the field of CT imaging. Two x-ray sources operated simultaneously enable heart-rate independent temporal resolution and routine spiral dual energy imaging. The precise delivery of contrast media is a critical part of the contrast-enhanced CT procedure. This book provides an introduction to DSCT technology and to the basics of contrast media administration followed by 25 in-depth clinical scan and contrast media injection protocols. All were developed in consensus by selected physicians on the Dual Source CT Expert Panel. Each protocol is complemented by individual considerations, tricks and pitfalls, and by clinical examples from several of the world's best radiologists and cardiologists. This extensive CME-accredited manual is intended to help readers to achieve consistently high image quality, optimal patient care, and a solid starting point for the development of their own unique protocols. (orig.)

  16. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  17. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  18. Experimental study of quantity to be taken as patient dose in helical multi-slice CT scan

    International Nuclear Information System (INIS)

    Liu Lantao; Wei Kedao; Yue Brorong; Wang Jianchao

    2009-01-01

    Objective: To bring forward a novel quantity which is used to be taken as effective dose in helical multi - slice CT scan and to validate it by experiment. Methods: Dot chamber and pencil-chamber were used to measure the doses which were performed under axial mode and helical multi-slice mode. Then the readings of doses were compared and analyzed. Results: The dose reading from dot chamber was close to the one from pencil - chamber under axial mode. The ratio is 1.14 for the readings from dot chamber under two scan modes and is 2.88 for the readings from pencil-chamber under two scan modes. Conclusions: The dose measured from dot chamber is an effective quantity to be taken as effective dose. However it is insufficient that the CTDI and DLP be used to be taken as effective dose as the limitation of pencil-chamber in length. (authors)

  19. The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation

    International Nuclear Information System (INIS)

    Hof, H.; Herfarth, K.K.; Muenter, M.; Debus, J.; Essig, M.; Wannenmacher, M.

    2003-01-01

    Background: In three-dimensional (3-D) precision high-dose radiation therapy of lung tumors, the exact definition of the planning target volume (PTV) is indispensable. Therefore, the feasibility of a 3-D determination of respiratory lung tumor movements by the use of a multislice CT scanner was investigated. Patients and Methods: The respiratory motion of 21 lung tumors in 20 consecutively treated patients was examined. An abdominal pressure device for the reduction of respiratory movement was used in 14 patients. Two regions of the tumor were each scanned repeatedly at the same table position, showing four simultaneously acquired slices for each cycle. Stereotactic coordinates were determined for one anatomic reference point in each tumor region (Figure 1). The 3-D differences of these coordinates between the sequentially obtained cycles were assessed (Figure 2), and a correlation with the tumor localization was performed. Results: In the craniocaudal (Z-)direction the mean tumor movement was 5.1 mm (standard deviation [SD] 2.4 mm, maximum 10 mm), in the ventrodorsal (Y-)direction 3.1 mm (SD 1.5 mm, maximum 6.7 mm), and in the lateral (X-)direction 2.6 mm (SD 1.4 mm, maximum 5.8 mm; Figures 3 to 5). Inter- and intraindividual differences were present in each direction. With an abdominal pressure device no clinically significant difference between tumors in different locations was seen. Conclusion: The 3-D assessment of lung tumor movements due to breathing is possible by the use of multislice CT. The determination, indispensable to the PTV definition, should be performed individually for several regions, because of the inter- and intraindividual deviations detected. (orig.)

  20. Heterogeneity of Multiple Sclerosis Lesions in Multislice Myelin Water Imaging.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available To assess neuroprotection and remyelination in Multiple Sclerosis (MS, we applied a more robust myelin water imaging (MWI processing technique, including spatial priors into image reconstruction, which allows for lower SNR, less averages and shorter acquisition times. We sought to evaluate this technique in MS-patients and healthy controls (HC.Seventeen MS-patients and 14 age-matched HCs received a 3T Magnetic Resonance Imaging (MRI examination including MWI (8 slices, 12 minutes acquisition time, T2w and T1mprage pre and post gadolinium (GD administration. Black holes (BH, contrast enhancing lesions (CEL and T2 lesions were marked and registered to MWI. Additionally, regions of interest (ROI were defined in the frontal, parietal and occipital normal appearing white matter (NAWM/white matter (WM, the corticospinal tract (CST, the splenium (SCC and genu (GCC of the corpus callosum in patients and HCs. Mean values of myelin water fraction (MWF were determined for each ROI.Significant differences (p≤0.05 of the MWF were found in all three different MS-lesion types (BH, CEL, T2 lesions, compared to the WM of HCs. The mean MWF values among the different lesion types were significantly differing from each other. Comparing MS-patients vs. HCs, we found a significant (p≤0.05 difference of the MWF in all measured ROIs except of GCC and SCC. The mean reduction of MWF in the NAWM of MS-patients compared to HCs was 37%. No age, sex, disability score and disease duration dependency was found for the NAWM MWF.MWF measures were in line with previous studies and lesions were clearly visible in MWI. MWI allows for quantitative assessment of NAWM and lesions in MS, which could be used as an additional sensitive imaging endpoint for larger MS studies. Measurements of the MWF also differ between patients and healthy controls.

  1. Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, Mate [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary); Janos Szentagothai PhD School, MR Research Centre, Budapest (Hungary); National Institute of Clinical Neuroscience, Department of Neuroradiology, Budapest (Hungary); Hermann, Petra; Vidnyanszky, Zoltan; Gal, Viktor [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary)

    2018-03-15

    To maintain alertness and to remain motionless during scanning represent a substantial challenge for patients/subjects involved in both clinical and research functional magnetic resonance imaging (fMRI) examinations. Therefore, availability and application of new data acquisition protocols allowing the shortening of scan time without compromising the data quality and statistical power are of major importance. Higher order category-selective visual cortical areas were identified individually, and rapid event-related fMRI design was used to compare three different sampling rates (TR = 2000, 1000, and 410 ms, using state-of-the-art simultaneous multislice imaging) and four different scanning lengths to match the statistical power of the traditional scanning methods to high sampling-rate design. The results revealed that ∝ 4 min of the scan time with 1 Hz (TR = 1000 ms) sampling rate and ∝ 2 min scanning at ∝ 2.5 Hz (TR = 410 ms) sampling rate provide similar localization sensitivity and selectivity to that obtained with 11-min session at conventional, 0.5 Hz (TR = 2000 ms) sampling rate. Our findings suggest that task-based fMRI examination of clinical population prone to distress such as presurgical mapping experiments might substantially benefit from the reduced (20-40%) scanning time that can be achieved by the application of simultaneous multislice sequences. (orig.)

  2. The value of multislice helical CT in the diagnosis of the rib micro-fracture

    International Nuclear Information System (INIS)

    Wang Shuli; Wang Linsen; Sun Dingyuan; Deng Xin; Geng Xin; Li Jian; Liu Zhigang; Guo Lin; Jia Zhihong

    2005-01-01

    Objective: To evaluate the clinical value of MSCT with thin-section reconstruction and curved multiplanar reformation of rib micro-fracture. Methods: Thirty-eight patients suspected ribs fracture by clinical examination, which had negative appearance in X-ray film, were performed with MSCT scan with thin-section reconstructed and curved multiplanar reformation. The imaging of 5 mm, 1 mm thickness and curved reformatted imags were analysed by three groups of radiologists respectively. Results: Of the 38 patients, 26 patients were demonstrated ribs fracture with 1 mm thin-section reconstructed and curved multiplanar reformatted CT imaging, which were classified as complete fracture in 18 ribs and incomplete fracture in 41 ribs. The ends of the fractures displacement located within a distance of double-thickness of the cortex of the complete ribs fracture. With 5 mm thickness imaging, the accuracy of the diagnosis was 86.4%, 89.8% and 94.9% by three groups radiologists, respectively. Conclusion: The rib fracture is very common in clinic, the incomplete and non evident displacement complete ribs fracture are difficult to be diagnosed by plain radiography. The MSCT can produce a large range volume information scan. Thin-section reconstructed and curved multiplanar reformatted imaging should be the effective method in diagnosis of ribs fracture. The total rib pattern and location, extend of all the ribs fracture in this cases can be displayed in one scan by the curved multiplanar reformatted imaging. (authors)

  3. CT image of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Morioka, Nobuo; Shudo, Yuji; Jahana, Masanobu; Matsuki, Tsutomu; Kotani, Kazuhiko (Tottori Univ., Yonago (Japan). School of Medicine)

    1983-10-01

    Computor tomographic images of 11 patients who had had thymectomy for myasthenia gravis or thymoma were studied retrospectively. Of those 11 patients, malignant thymoma and benign condition including normal thymus were 6 and 5 respectively. On CT, calcification and lobulation with irregular margin seem to be reliable findings of malignancy. Defect or abscence of fatty plane and non-homogenous density are ancillary.

  4. CT image of thymoma

    International Nuclear Information System (INIS)

    Morioka, Nobuo; Shudo, Yuji; Jahana, Masanobu; Matsuki, Tsutomu; Kotani, Kazuhiko

    1983-01-01

    Computor tomographic images of 11 patients who had had thymectomy for myasthenia gravis or thymoma were studied retrospectively. Of those 11 patients, malignant thymoma and benign condition including normal thymus were 6 and 5 respectively. On CT, calcification and lobulation with irregular margin seem to be reliable findings of malignancy. Defect or abscence of fatty plane and non-homogenous density are ancillary. (author)

  5. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  6. Study on bone mineral density and bone structure of lumbar vertebrae in osteoporotic elderly women with multi-slice CT

    International Nuclear Information System (INIS)

    Wu Shengyong; Qi Ji; Wang Bin; Wen Lianqing

    2005-01-01

    Objective: To evaluate the ability of volumetric bone mineral density (BMD) parameters of lumbar vertebrae in differentiating osteoporotic fractured from nonfractured elderly women with vQCT technique, and to compare the bony structural conditions of osteoporotic elderly women with healthy elderly women. Methods: Multi-slice CT spinal scans of L1 and L2 were acquired in 26 osteoporotic vertebral fractured elderly women (group one) and 30 nonfractured osteoporotic subjects (group two). All the retro-reconstructed images of L1 and L2 were sent to the workstation and processed by volume rendering (VR) technique to measure volumetric BMD (3D-INTGL, 3D-CORT, 3D-TRAB) and trabecular and integral BMD (2D-TRAB, 2D-INTGL) by conventional QCT technique. BMD indexes in DXA were AP-SPINE and bone mineral apparent density (BMAD) in anteroposterior position. The seven parameters between the two group s were compared. Ten healthy elderly women were selected as normal group to reformate 3D-VR images from MSCT images to analyze the bony structure and calculate the ratio of bone volume to total volume (BV/TV) in the center of L1 vertebrae, and to compare the index between the normal group and tenpatients randomly selected from the 56 osteoporotic women. Results: DXA measurements in group one: AP-SPINE and BMAD were (0.796±0.170)g/cm 2 and (272.7±27.7) mg/cm 3 , respectively, showing no statistically significant differences comparing with (0.817±0.140) g/cm 2 and (249.5 ± 26.5) mg/cm 3 in group two. Volumetric BMD in group one included 2D-TRAB (70.4 ± 22.2) mg/cm 3 , 2D-INTGL (138.3±35.1) mg/cm 3 , 3D-INTGL (139.4±34.9 ) mg/cm 3 , 3D-CORT (133.8±26.9) mg/cm 3 , and 3D-TRAB (69.9 ±18.6) mg/cm 3 , respectively, showing statistically differences with (89.1±21.8) mg/cm 3 , (170.6±34.5) mg/cm 3 , (180.5±28.2) mg/cm 3 , (163.2±27.5) mg/cm 3 , and (83.8 ± 17.1) mg/cm 3 in group two (the decrements 18%-23%). The mean value of BV/TV of L1 vertebrae was (8.12 ± 1.96)% in

  7. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Pradip, Joe; Dinakran, Paul M.; Srikanth, B.

    2010-01-01

    Objectives: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tube potential of 140 kV; mAs values were automatically selected by the machine. Effective doses were calculated using dose-length product (DLP) values and the image quality was assessed using the signal-to-noise (SNR) ratio values. Mean effective doses using manual protocol for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 8.58 mSv, 8.54 mSv, and 9.07 mSv, respectively. Mean effective doses using z-axis dose modulation for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 4.95 mSv, 6.87 mSv, and 10.24 mSv, respectively. The SNR at the region of the liver for patients of body weight of 40-60 kg was 5.1 H, 6.2 H, and 8.8 H for manual, angular, and z-axis dose modulation, respectively. Conclusion: Dose reduction of up to 15% was achieved using angular dose modulation and of up to 42% using z-axis dose modulation, with acceptable diagnostic image quality compared to the manual protocol. (author)

  8. Assessment of colonic disease by multi-slice CT pneumocolon after incomplete colonoscopy

    International Nuclear Information System (INIS)

    Zhao Zehua; Liu Wenjin; Xu Songsen; Wang Kang; Wang Weizhong

    2004-01-01

    Objective: To evaluate the use of preoperative MSCT in patients with clinically suspected colorectal disease after incomplete colonoscopy. Methods: After incomplete colonoscopy, 31 patients underwent MSCT before and after intravenous injection of iodinated contrast agent. CT virtual colonography (CTVC), multiplanar reformation (MPR), shaded surface display (SSD), and Raysum images were obtained by using 4 different software in workstation. The results of MSCT were compared with the findings of colonoscopy, intraoperative colon palpation, and postoperative pathology. Results: After incomplete colonoscopy, MSCT was successfully performed in all 31 cases. Postoperative pathology revealed 22 colorectal cancers (one synchronous cancers, two with polyps) and 9 benign disease. 22 colonic carcinomas were all correctly diagnosed by MSCT (including synchronous disease), 2 benign diseases were misdiagnosed as malignancy, and one polyp was missed. Conclusion: MSCT is a feasible and useful method for evaluating the entire colon before surgery in patients with occlusive disease. (author)

  9. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data

    Energy Technology Data Exchange (ETDEWEB)

    Klintstroem, Eva; Smedby, Oerjan [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); UHL County Council of Oestergoetland, Department of Radiology, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Moreno, Rodrigo [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Brismar, Torkel B. [KUS Huddinge, Department of Clinical Science, Intervention and Technology at Karolinska Institutet and Department of Radiology, Stockholm (Sweden)

    2014-02-15

    Bone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference. Fifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained. The clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini. The high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT. (orig.)

  10. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Value of an early arteriographic acquisition for evaluating the splanchnic vessels as an adjunct to biphasic CT using a multislice scanner

    Energy Technology Data Exchange (ETDEWEB)

    Zandrino, F.; Curone, P.; Benzi, L.; Musante, F. [Department of Radiology, Azienda Ospedaliera ' ' SS Antonio e Biagio e C. Arrigo' ' , Via Venezia 16, 15100 Alessandria (Italy)

    2003-05-01

    Our objective was to assess the clinical value of an early arterial scan for assessing the hepatic and mesenteric vasculature in patients with suspected primary or metastatic hypervascular liver disease undergoing multislice computed tomography. In 42 patients a very early arteriographic scan was performed before standard arterial and portal venous scans. Technical parameters of the very early acquisition were: 2.5-mm image thickness; table speed 15 mm/s; pitch 6; 120 kVp; 300 mA; 8.9-s scan time; cranio-caudal acquisition direction; 1.25-mm image interval reconstruction;16-s delay after injection of 110 ml of iodinated contrast agent at 5 ml/s; scan volume focused to image hepatic, splenic, and superior mesenteric arteries (SMA). Standard arterial and portal venous phases were performed with 5-mm image thickness, 15-mm/s table speed, pitch 6, 8- to 10-s scan time, 30- and 70-s delay. The three phases were performed during three different breath-holds. Axial, multiplanar reformatted, maximum intensity projection, and volume-rendering images were evaluated. Image quality was scored, and vascular abnormalities were recorded. Digital subtraction angiography (DSA) was performed in 17 patients. In 36 of 42 patients good-quality CT angiograms were obtained. In 9 patients 12 vascular abnormalities were found, all confirmed at DSA: 3 right hepatic arteries originating from the SMA, 2 left hepatic arteries from the gastric artery, 2 stenoses of the SMA, 1 independent origin of the hepatic and splenic arteries, 2 arteriovenous fistulas, and 2 aneurysms of the common hepatic artery and the SMA. This technique could add important information about vascular splanchnic anatomy which would be particularly useful for surgeons and interventional radiologists. (orig.)

  12. Multislice imaging of integrated circuits by precession X-ray ptychography.

    Science.gov (United States)

    Shimomura, Kei; Hirose, Makoto; Takahashi, Yukio

    2018-01-01

    A method for nondestructively visualizing multisection nanostructures of integrated circuits by X-ray ptychography with a multislice approach is proposed. In this study, tilt-series ptychographic diffraction data sets of a two-layered circuit with a ∼1.4 µm gap at nine incident angles are collected in a wide Q range and then artifact-reduced phase images of each layer are successfully reconstructed at ∼10 nm resolution. The present method has great potential for the three-dimensional observation of flat specimens with thickness on the order of 100 µm, such as three-dimensional stacked integrated circuits based on through-silicon vias, without laborious sample preparation.

  13. Simultaneous multislice echo planar imaging with blipped controlled aliasing in parallel imaging results in higher acceleration: a promising technique for accelerated diffusion tensor imaging of skeletal muscle

    OpenAIRE

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-01-01

    PURPOSE The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. MATERIALS AND METHODS After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic ...

  14. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  15. Value of 3D-Volume Rendering in the Assessment of Coronary Arteries with Retrospectively Ecg-Gated Multislice Spiral CT

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Dedden, K.; Schmitz-Rode, T.; Guenther, R.W.; Sinha, A.M.; Hoffmann, R.; Stanzel, S.

    2003-01-01

    Purpose: To assess the diagnostic value and measurement precision of 3D volume rendering technique (3D-VRT) from retrospectively ECG-gated multislice spiral CT (MSCT) data sets for imaging of the coronary arteries. Material and Methods: In 35 patients, retrospectively ECG-gated MSCT of the heart using a four detector row MSCT scanner with a standardized examination protocol was performed as well as quantitative X-ray coronary angiography (QCA). The MSCT data was assessed on segmental basis using 3D-VRT exclusively. The coronary artery diameters were measured at the origin of each main coronary branch and 1 cm, 3 cm and 5 cm distally. The minimum, maximum and mean diameters were determined from MSCT angiography and compared to QCA. Results: A total of 353 of 525 (67.2%) coronary artery segments were assessable by MSCT angiography. The proximal segments were more often assessable when compared to the distal segments. Stenoses were detected with a sensitivity of 82.6% and a specificity of 92.8%. According to the Bland-Altman method the mean differences between QCA and MSCT ranged from 0.55 to 1.07 mm with limits of agreement from 2.2 mm to 2.7 mm. Conclusion: When compared to QCA, the ability of 3D-VRT to quantitatively assess coronary artery diameters and coronary artery stenoses is insufficient for clinical purposes

  16. Dual-phase contrast enhancement multi-slice CT in grading pancreatic neuroendocrine tumors

    International Nuclear Information System (INIS)

    Zhou Yan; Liu Jianyu; Zhu Xiang

    2013-01-01

    Objective: To evaluate characteristic clinical and imaging findings of pancreatic neuroendocrine tumors (NET) in dual-phase contrast enhancement MSCT. Methods: The dual-phase contrast enhancement MSCT images of 23 lesions in 20 patients with histologically confirmed pancreatic NET were studied retrospectively. Their clinical presentations, imaging characters as well as the intensities of lesions and normal pancreas in each phase were measured, and the following indices were calculated. First, the absolute enhancement of lesions, including the increasing of CT value of the maximum enhancement area within a tumor in arterial phase, that was named A1 in short, and that of the minimum enhancement area was labeled as A2. The same ROI measured increasing CT values in portal venous phase was labeled as V1 and V2 respectively. Secondly, the relatively enhancement indices comparing with the normal pancreas in the same patient within the same phase were calculated. This included the differences between the maximum, as well as the minimum, enhancement areas of tumors and the normal pancreas in arterial phase, which was named as AP1 and AP2 respectively, and those differences in portal venous phase, which were labeled as VP1 and VP2 respectively. All of the tumors were graded as G1 to G3 according to the WHO classification in 2010. A Kruskal Wallis test were performed to compare differences of tumor diameters and the enhancement indices. The change trend of enhancement indices varying with pathology grading were described. Fisher exact test was used to find differences of clinical and imaging characters. Results: Twenty-three lesions in 20 patients included 13 lesions in grade 1 (G1), 8 in G2, and 2 in G3. Among the 10 patients with G1 NET, 7 of them had no endocrine symptoms, while the other 3 had endocrine symptoms. Six of them had no abdominal pain, while 4 of them complained of it. All of the 10 patients with G1 NET had no hepatic metastasis. Among 8 patients with G2 NET

  17. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  18. Experimental study of multi-slice CT for the evaluation of atherosclerotic plaques

    International Nuclear Information System (INIS)

    Tang Xiang; Lv Bin; Wu Wenhui; Lu Jinguo; Dai Ruping; Bai Hua; Tang Yue; Lv Fengying; Jiang Shiliang

    2009-01-01

    Objective: To evaluate the diagnostic values of MSCT for detecting atherosclerotic plaques on New Zealand rabbits models in comparison with pathologic results. Methods: Fifteen New Zealand rabbits were enrolled in this study, including 5 with balloon injury and high-fat diet (group A), 5 with high-fat diet only (group B) and 5 with regular feed (group C). 16th week late, contrast-enhanced MSCT scan was performed in all rabbits with 16 slice MSCT (16-MSCT) in group A and 64 slice MSCT (64-MSCT) in group B and C. The CT and pathological findings were compared in a double-blind manner. The sensitivities and specificities of 16-MSCT and 64-MSCT for detecting atherosclerotic plaques were evaluated by using Fisher test and χ 2 test. Results: Sixty and seventy-five images on 16-MSCT and 64-MSCT had corresponding pathological slices. The sensitivities for the detection of plaques on 16-MSCT and 64-MSCT were 41.5% (22/53) and 64.9% (24/37), and specificities of 85.7% (6/7) and 89.5% (34/38), respectively. Conclusions: 64-MSCT has a higher sensitivity in the detection of atherosclerotic plaques than 16-MSCT. Both scanners can be used to preclude the diagnosis of atherosclerosis. (authors)

  19. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  20. Blurring of the vessels of the interhemispheric fissure in multislice CT angiography: a sign of meningeal carcinomatosis

    International Nuclear Information System (INIS)

    Ertl-Wagner, Birgit B.; Hoffmann, Ralf-Thorsten; Herrmann, Karin; Reiser, Maximilian F.; Bruening, Roland; Dichgans, Martin

    2004-01-01

    Meningeal carcinomatosis remains a challenging diagnosis to make, with both cerebrospinal fluid (CSF) analysis and radiological methods having a limited sensitivity. We aimed at describing a possible diagnostic sign of multislice CT angiography (MS-CTA) in the diagnosis of meningeal carcinomatosis. Upon retrospective analysis of MSCT angiographies of the brain, a conspicuous sign of the vessels of the interhemispheric fissure was noted in five patients. Cranial MSCT angiographies were performed with a standardized protocol (120 kV, 200 mA s, collimation of 4 x 1 mm, table feed per rotation 4 mm). We injected 120 ml of nonionic contrast medium as a bolus, and data acquisition was started after a fixed delay of 35 s. In order to elucidate the finding, correlation with clinical follow-up and/or CSF findings was performed for all patients. In five patients there was a blurring, an increased number, and a pathologic configuration of the vessels of the interhemispheric fissure. All five patients with this sign had clinical signs and symptoms of meningeal carcinomatosis. Three patients had positive CSF cytology, one further patient had follow-up spinal MRI 6 weeks later demonstrating meningeal carcinomatosis. One patient declined lumbar puncture. MS-CTA has the capacity to demonstrate a pathologic configuration of the vessels of the interhemispheric fissure in patients with meningeal carcinomatosis. This sign may serve as an indicator of meningeal carcinomatosis and should raise the suspicion of this disease entity. (orig.)

  1. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  2. A differentiated approach to the diagnosis of pulmonary embolism and deep venous thrombosis using multi-slice CT

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Stargardt, A.; Haage, P.; Guenther, R.W.; Sinha, A.M.; Schaller, S.

    2002-01-01

    Purpose: To establish a differentiated protocol for multi-slice CT (MSCT) examinations in cases of clinically suspected pulmonary embolism (PE) using pulmonary CT-angiography (CTA) and indirect CT-phlebography (CTP). Materials and Methods: 161 patients with suspected PE were examined using an MSCT (SOMATOM Volume Zoom; Siemens, Forchheim, Germany). After intravenous administration of 120 ml of contrast material, a thin collimation chest-CT scan was performed (120 kV, 100 mAs, collimation: 4 x 1 mm). If PE was present, or previous examinations and clinical signs suggested deep venous thrombosis (DVT), a CTP was subsequently completed. CTPs were performed using a 4 x 5 mm protocol (120 kV, 170 mAs). Venous phase scanning, starting from the pelvic crest, was completed in the popliteal fossa three minutes after contrast material injection. In 73 extremities, CTP were compared to the results of ultrasound, phlebography and autopsy. Scan ranges were documented in all patients. Cumulative doses were calculated for male and female subgroups. Results: 62 patients in our series suffered from PE and in 47 of these patients deep venous thrombosis was seen additionally. Of the 99 patients without PE, 47 also received indirect CTP. CTP confirmed the suspicion and extent of DVT in 8 patients. Only in 2 of 39 patients (5.1%) was previously unknown DVT found, despite the exclusion of PE. Regarding DVT, sensitivity was 94.3% and specificity was 92.1% for indirect CTP. Cumulative chest CT doses averaged 3.3 mSv for males and 4.2 mSv for females, the calculated CTP dosage was 9.3 mSv (according to ICRP 60). Conclusions: the examination protocol presented its suitable for clinical usage in patients with suspected PE. If PE is confirmed, indirect CTP is justified, so that detailed information of the venous system can be obtained. However, the relatively high radiation dosage of an additional CTP requires a strict indication regiment in patients with a negative CTA. (orig.) [de

  3. Modern diagnostic assessment of the upper urinary tract using multislice CT urography; Moderne Diagnostik des oberen Harntraktes mittels Mehrschicht-CT-Urographie

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G.; Nolte-Ernsting, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-11-15

    The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of 'Multislice CT Urography (MSCTU)' has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of kidney basin cup system and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract. (orig.)

  4. Subtraction imaging of the ECG gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanegashima, K.; Fukui, M.; Hyodo, H.

    1987-05-01

    The subtracting manipulation of contrast-enhanced gated cardiac CT (GCCT) images was experimentally studied with TCT 60A - 30 type (Toshiba) for clinical use, thereby reducing the amount of contrast medium (CM). Initially the optimum relationship between the concentration of CM and its injected velocity was determined using the model of resected canine hearts and in actual dogs. The emphasized good-subtracted images were obtained when the difference of CT values was approximately 40 H.U. between cardiac cavity and myocardium. Such condition was feasible in the use of 25 % Diatrizoic acid and its injected velocity of 0.02 ml/kg/sec. Finally the reduction of the amount of CM by 1/3 became possible in clinical settings. The method is applicable to multi-slice GCCT in various heart diseases.

  5. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  6. Bias field inconsistency correction of motion-scattered multislice MRI for improved 3D image reconstruction.

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A; Rajagopalan, Vidya; Scott, Julia A; Corbett-Detig, James M; Rousseau, Francois; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2011-09-01

    A common solution to clinical MR imaging in the presence of large anatomical motion is to use fast multislice 2D studies to reduce slice acquisition time and provide clinically usable slice data. Recently, techniques have been developed which retrospectively correct large scale 3D motion between individual slices allowing the formation of a geometrically correct 3D volume from the multiple slice stacks. One challenge, however, in the final reconstruction process is the possibility of varying intensity bias in the slice data, typically due to the motion of the anatomy relative to imaging coils. As a result, slices which cover the same region of anatomy at different times may exhibit different sensitivity. This bias field inconsistency can induce artifacts in the final 3D reconstruction that can impact both clinical interpretation of key tissue boundaries and the automated analysis of the data. Here we describe a framework to estimate and correct the bias field inconsistency in each slice collectively across all motion corrupted image slices. Experiments using synthetic and clinical data show that the proposed method reduces intensity variability in tissues and improves the distinction between key tissue types.

  7. Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.; Hoffmann, H.

    2006-01-01

    Purpose: to investigate the influence of sublingual glycerol trinitrate (1.2 mg, Nitrate [nitroglycerine], Nitrolingual N spray) on the coronary artery diameter on multislice computed tomography (MSCT) coronary angiography. Materials and methods: out of our database of patients who underwent MSCT (slice thickness of 0.5 mm, Aquilion, Toshiba) coronary angiography between July 2003 and November 2005 (950 patients) we retrospectively identified patients with follow-up examinations who received Nitrate for one examination while another examination was performed without Nitrate (10 patients). Another 10 patients who underwent two MSCT examinations with sublingual Nitrate administration were randomly selected from this database to serve as control group. For the resulting 40 MSCT examinations, blinded MSCT datasets were prepared, which were randomly evaluated by a reader blinded to the patient information and whether or not Nitrate had been given. The proximal coronary artery diameters were measured for the left main coronary artery (LMA), the left anterior descending coronary artery (LAD), the left circumflex coronary artery (LCX), and the right coronary artery (RCA) in all 40 datasets, resulting in altogether 160 measurements. Results: the proximal diameters of all four coronary arteries were significantly larger on the MSCT coronary angiograms obtained after sublingual administration of Nitrate compared with the examinations in the same 10 patients without Nitrate (p < 0.001). The average diameters without and with Nitrate for the LMA, LAD, LCX, and RCA were 4.3 ± 1.1 vs. 4.8 ± 0.9 mm (12% increase, p < 0.005), 3.0 ± 0.6 vs. 3.5 ± 0.5 mm (17% increase, p < 0.001), 2.7 ± 0.6 vs. 3.2 ± 0.7 mm (19% increase, p < 0.005), and 2.9 ± 0.9 vs. 3.5 ± 0.7 mm (21% increase, p < 0.005), respectively. In the control group of 10 patients who underwent two MSCT coronary angiographies after sublingual Nitrate, no significant difference in the proximal diameter of all four

  8. Value of cardiac multislice spiral CT for the assessment of degenerative aortic stenosis: comparison with echocardiography

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Das, M.; Muehlenbruch, G.; Guenther, R.W.; Koos, R.; Sinha, A.M.; Stanzel, S.

    2004-01-01

    Objective: To non-invasively assess the severity of aortic valve stenosis (AS) by the determination of aortic valve calcification (AVC) using multislice spiral computed tomography (MSCT). Materials and Methods: Forty-one consecutive patients (17 male, 24 female, mean age 71.0±7.9 years) with a history of AS and an aortic valve area ≤2 cm 2 underwent retrospectively ECG-gated 4-slice MSCT and echocardiography. The AVCs were quantitatively assessed using the score described by Agatston as well as by calculating the calcium mass. The echocardiographically determined aortic valve area (AVA) and the severity of AS according to the ACC/AHA guidelines were compared to the degree of a aortic valve calcifications. Pearson's correlation coefficient, cut-off values, kappa test and F-test with post hoc Boneferroni t-tests were calculated. Results: Calcium scores were significantly higher in patients with severe AS, when compared to mild or moderate AS (p<0.001). In patients suffering from severe AS, the mean Agatston score was 4125.5±1168.9 (calcium mass 904.1±263.3) while in patients with moderate and mild AS the corresponding values were 1596.3±987.0 (319.1±208.3) and 785.9±390.1 (149.1±90.2), respectively. Pearson's correlation coefficients were r-=0.75 for the Agatston score and r=-0.72 for the calcium mass. There was a moderate agreement between severity of AS according to the ACC/AHA guidelines and the degree of AS determined from AVC scores with κ=0.6091 and κ=0.6985, respectively. Conclusion: Severe AS may be differentiated from moderate or mild AS using cardiac MSCT. Extensive calcifications of the aortic valve presenting with an Agatston-Score ≥2824 (calcium mass ≥611) indicate a severe AS and should be taken as an indication for further diagnostic workup. (orig.)

  9. Intersection based motion correction of multislice MRI for 3-D in utero fetal brain image formation.

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A; Rousseau, Francois; Glenn, Orit A; Barkovich, Anthony J; Studholme, Colin

    2010-01-01

    In recent years, postprocessing of fast multislice magnetic resonance imaging (MRI) to correct fetal motion has provided the first true 3-D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two-step iterative process, where slices from the acquired data are realigned to an approximate 3-D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3-D reconstruction, and is limited in its ability to recover subvoxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3-D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3-D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3-D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3-D reconstructions containing clinically useful additional information not visible in the original 2-D slices.

  10. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  11. Nutcracker Syndrome Accompanying Pelvic Congestion Syndrome; Color Doppler Sonography and Multislice CT Findings: A Case Report

    International Nuclear Information System (INIS)

    Inal, Mikail; Karadeniz Bilgili, Mihrace Yasemin; Sahin, Safa

    2014-01-01

    Nutcracker syndrome (NCS) is a rare pathology, caused by compression of the left renal vein (LRV) between the abdominal aorta (AA) and the superior mesenteric artery (SMA), due to reduction of the angle between AA and SMA. This leads to LRV varices, left gonadal vein varices and therefore, the pelvic congestion syndrome. For this reason, coexistence of NCS and pelvic congestion syndrome has been described. It manifests by hematuria, proteinuria, and nonspecific pelvic pain secondary to pelvic congestion, dyspareunia and persistent genital arousal. We report a 27-year-old woman who experienced hematuria and left flank pain. The diagnosis of NCS accompanied by pelvic congestion syndrome was missed initially, but later on the diagnosis was made by color Doppler ultrasound, abdominal computed tomography (CT) and CT angiography that were later performed. She refused interventional and surgical treatments, and was lost to follow up

  12. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  13. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  14. A multislice single breath-hold scheme for imaging alveolar oxygen tension in humans.

    Science.gov (United States)

    Hamedani, Hooman; Kadlecek, Stephen J; Emami, Kiarash; Kuzma, Nicholas N; Xu, Yinan; Xin, Yi; Mongkolwisetwara, Puttisarn; Rajaei, Jennia; Barulic, Amy; Wilson Miller, G; Rossman, Milton; Ishii, Masaru; Rizi, Rahim R

    2012-05-01

    Reliable, noninvasive, and high-resolution imaging of alveolar partial pressure of oxygen (p(A)O(2)) is a potentially valuable tool in the early diagnosis of pulmonary diseases. Several techniques have been proposed for regional measurement of p(A)O(2) based on the increased depolarization rate of hyperpolarized (3) He. In this study, we explore one such technique by applying a multislice p(A)O(2) -imaging scheme that uses interleaved-slice ordering to utilize interslice time-delays more efficiently. This approach addresses the low spatial resolution and long breath-hold requirements of earlier techniques, allowing p(A)O(2) measurements to be made over the entire human lung in 10-15 s with a typical resolution of 8.3 × 8.3 × 15.6 mm(3). PO(2) measurements in a glass syringe phantom were in agreement with independent gas analysis within 4.7 ± 4.1% (R = 0.9993). The technique is demonstrated in four human subjects (healthy nonsmoker, healthy former smoker, healthy smoker, and patient with COPD), each imaged six times on 3 different days during a 2-week span. Two independent measurements were performed in each session, consisting of 12 coronal slices. The overall p(A)O(2) mean across all subjects was 95.9 ± 12.2 Torr and correlated well with end-tidal O(2) (R = 0.805, P < 0.0001). The alveolar O(2) uptake rate was consistent with the expected range of 1-2 Torr/s. Repeatable visual features were observed in p(A)O(2) maps over different days, as were characteristic differences among the subjects and gravity-dependent effects. Copyright © 2011 Wiley Periodicals, Inc.

  15. Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography.

    Directory of Open Access Journals (Sweden)

    Richard Nolz

    Full Text Available To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction.The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated.Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09, and in venous sets of 73.3 versus 79.4 (p = 0.15, respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01. Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase.Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.

  16. A comparison of shielding calculation methods for multi-slice computed tomography (CT) systems

    International Nuclear Information System (INIS)

    Cole, J A; Platten, D J

    2008-01-01

    Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. Additionally, more recent shielding methods have been proposed by the NCRP (National Council on Radiation Protection) from the USA. Thermoluminescent detectors (TLDs) were placed in three CT scanner rooms at different positions for several weeks before being processed. Patient workload and dose data (DLP: the dose length product and mAs: the tube current-time product) were collected for this period. Individual dose data were available for more than 95% of patients scanned and the remainder were estimated. The patient workload data were used to calculate expected scatter radiation for each TLD location by both the NCRP and BIR-IPEM methods. The results were then compared to the measured scattered radiation. Calculated scattered air kerma and the minimum required lead shielding were found to be frequently overestimated compared to the measured air kerma, on average almost five times the measured scattered air kerma.

  17. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  18. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  19. The “dirty chest”—correlations between chest radiography, multislice CT and tobacco burden

    Science.gov (United States)

    Kirchner, J; Goltz, J P; Lorenz, F; Obermann, A; Kirchner, E M; Kickuth, R

    2012-01-01

    Objectives Cigarette smoking-induced airway disease commonly results in an overall increase of non-specific lung markings on chest radiography. This has been described as “dirty chest”. As the morphological substrate of this condition is similar to the anthracosilicosis of coal workers, we hypothesised that it is possible to quantify the radiological changes using the International Labour Organization (ILO) classification of pneumoconiosis. The aims of this study were to evaluate whether there is a correlation between the extent of cigarette smoking and increased lung markings on chest radiography and to correlate the chest radiographic scores with findings on CT studies. Methods In a prospective analysis a cohort of 85 smokers was examined. The cigarette consumption was evaluated in pack years (defined as 20 cigarettes per day over 1 year). Film reading was performed by two board-certified radiologists. Chest radiographs were evaluated for the presence of thickening of bronchial walls, the presence of linear or nodular opacities, and emphysema. To correlate the smoking habits with the increase of overall lung markings in chest radiography, the ILO profusion score was converted to numbers ranging from zero to nine. Chest radiographs were rated according to the complete set of standard films of the revised ILO classification. Results 63/85 (74%) of the smokers showed an increase in overall lung markings on chest radiography; 32 (37%) had an ILO profusion score of chest radiography and the cigarette consumption quantified as pack years (r=0.68). The majority of the heavy smokers (>40 pack years) showed emphysema; there was no significant difference between the prevalence of emphysema as diagnosed by CT (62%) or chest radiography (71%) (pchest radiography. PMID:21937617

  20. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  1. TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

    Energy Technology Data Exchange (ETDEWEB)

    Howansky, A; Peng, B; Lubinsky, A; Zhao, W [Stony Brook University, Stony Brook, NY (United States)

    2016-06-15

    Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of

  2. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  3. A pilot study of three dimensional color CT images of brain diseases to improve informed consent

    International Nuclear Information System (INIS)

    Tanizaki, Yoshio; Akiyama, Takenori; Hiraga, Kenji; Akaji, Kazunori

    2005-01-01

    We have described brain diseases to patients and their family using monochrome CT images. It is thought that patients have difficulties in giving their consent to our conventional explanation because their understanding of brain diseases is based on three dimensional and color images, however, standard CT images are two dimensional and gray scale images. We have been trying to use three dimensional color CT images to improve the typical patient's comprehension of brain diseases. We also try to simulate surgery using these images. Multi-slice CT accumulates precise isotropic voxel data within a half minute. These two dimensional and monochrome data are converted to three dimensional color CT images by 3D workstation. Three dimensional color CT images of each brain structures (e.g. scalp, skull, brain, ventricles and lesions) are created separately. Then, selected structures are fused together for different purposes. These images are able to rotate around any axis. Because the methods to generate three-dimensional color images have not established, we neurosurgeons must create these images. In particular, when an operation is required, the surgeon should create the images. In this paper, we demonstrate how three-dimensional color CT images can improve informed consent. (author)

  4. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    Energy Technology Data Exchange (ETDEWEB)

    Favazza, C; Yu, L; Leng, S; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  5. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    International Nuclear Information System (INIS)

    Favazza, C; Yu, L; Leng, S; McCollough, C

    2015-01-01

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  6. Visualization of normal and abnormal inner ear with volume rendering technique using multislice spiral CT

    International Nuclear Information System (INIS)

    Ma Hui; Han Ping; Liang Bo; Lei Ziqiao; Liu Fang; Tian Zhiliang

    2006-01-01

    Objective: To evaluate the ability of the volume rendering technique to display the normal and abnormal inner ear structures. Methods: Forty normal earand 61 abnormal inner ears (40 congenital inner ear malformations, 7 labyrinthitis ossificans, and 14 inner ear erosion caused by cholesteatomas) were examined with a MSCT scanner. Axial imaging were performed using the following parameters: 120 kV, 100 mAs, 0.75 mm slice thickness, a pitch factor of 1. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment and a FOV of 50 mm. The 3D reconstructions were done with volume rendering technique on the workstation. Results: In the subjects without ear disorders a high quality 3D visualization of the inner ear could be achieved. In the patients with inner ear' disorders all inner ear malformations could be clearly displayed on 3D images as follows: (1) Michel deformity (one ear): There was complete absence of all cochlear and vestibular structures. (2) common cavity deformity (3 ears): The cochlea and vestibule were represented by a cystic cavity and couldn't be differentiated from each other. (3)incomplete partition type I (3 ears): The cochlea lacked the entire modiolus and cribriform area, resulting in a cystic appearance. (4) incomplete partition type II (Mondini deformity) (5 ears): The cochlea consisted of 1.5 turns, in which the middle and apical turns coalesced to form a cystic apex. (5) vestibular and semicircular canal malformations (14 ears): Cochlea was normal, vestibule dilated, semicircular canals were absent, hypoplastic or enlarged. (6) dilated vestibular aqueduct (14 ears): The vestibular aqueduct was bell-mouthed. In 7 patients with labyrinthifis ossificans, 3D images failed to clearly show the completeinner ears in 4 ears because of too high ossifications in the membranous labyrinth. In the other 3 ears volume rendering could display the thin cochlea basal turn and the intermittent semicircular canals. In the patients

  7. Diagnostic Value of Multislice Computed Tomography and Magnetic Resonance Imaging in the Diagnosis of Retroperitoneal Spread of Testicular Cancer: A Literature Review

    International Nuclear Information System (INIS)

    Hansen, J.; Jurik, A.G.

    2009-01-01

    Testicular cancer is the most frequent malignant disorder in men aged 15-35 years. Generally, diagnosing and follow-up include computer tomography (CT) examinations to detect possible retroperitoneal spread (abdomen and pelvis), resulting in at least eight CT examinations. This patient group is thereby exposed to a non-neglectable radiation dose, increasing the risk of future radiation-induced secondary cancer. This is especially problematic in potentially surgically cured patients with stage 1 testicular cancer. Thus, it can be beneficial to substitute CT with magnetic resonance imaging (MRI), provided there is valid evidence that the diagnostic value of MRI is at least comparable to current multislice CT (MSCT). The purpose of this study was to analyze whether there is evidence to recommend a substitution of MSCT with MRI in the diagnosis of retroperitoneal spread of testicular cancer. A literature search on the diagnostic accuracy, specificity, and sensitivity of MSCT and MRI in the diagnosis of retroperitoneal spread of testicular cancer was performed in the following databases: PubMed, EmBase, and ISI Web of Science. The search was limited to include the period from 2000 to September 2008, and to human and English-language publications. Forty-four publications were obtained for formal review (27 from PubMed, 15 from EmBase, two from ISI Web of Science). None of the publications reviewed encompassed diagnostic specificity and sensitivity of MSCT, and they lacked systematic comparison of MSCT and MRI. Only one study included sensitivity and specificity of MRI compared to single-slice CT. Both methods had a sensitivity and a specificity of approximately 70%. The literature review did not reveal valid data regarding diagnostic accuracy of MRI compared with MSCT for diagnosing retroperitoneal spread of testicular cancer. A prospective blinded comparative study is needed to provide valid evidence

  8. Diagnostic Value of Multislice Computed Tomography and Magnetic Resonance Imaging in the Diagnosis of Retroperitoneal Spread of Testicular Cancer: A Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, J. (Dept. of Medical Physics, Aarhus Univ. Hospital, Aarhus Sygehus, Aarhus (Denmark)); Jurik, A.G. (Dept. of Radiology, Aarhus Univ. Hospital, Aarhus Sygehus, Aarhus (Denmark))

    2009-11-15

    Testicular cancer is the most frequent malignant disorder in men aged 15-35 years. Generally, diagnosing and follow-up include computer tomography (CT) examinations to detect possible retroperitoneal spread (abdomen and pelvis), resulting in at least eight CT examinations. This patient group is thereby exposed to a non-neglectable radiation dose, increasing the risk of future radiation-induced secondary cancer. This is especially problematic in potentially surgically cured patients with stage 1 testicular cancer. Thus, it can be beneficial to substitute CT with magnetic resonance imaging (MRI), provided there is valid evidence that the diagnostic value of MRI is at least comparable to current multislice CT (MSCT). The purpose of this study was to analyze whether there is evidence to recommend a substitution of MSCT with MRI in the diagnosis of retroperitoneal spread of testicular cancer. A literature search on the diagnostic accuracy, specificity, and sensitivity of MSCT and MRI in the diagnosis of retroperitoneal spread of testicular cancer was performed in the following databases: PubMed, EmBase, and ISI Web of Science. The search was limited to include the period from 2000 to September 2008, and to human and English-language publications. Forty-four publications were obtained for formal review (27 from PubMed, 15 from EmBase, two from ISI Web of Science). None of the publications reviewed encompassed diagnostic specificity and sensitivity of MSCT, and they lacked systematic comparison of MSCT and MRI. Only one study included sensitivity and specificity of MRI compared to single-slice CT. Both methods had a sensitivity and a specificity of approximately 70%. The literature review did not reveal valid data regarding diagnostic accuracy of MRI compared with MSCT for diagnosing retroperitoneal spread of testicular cancer. A prospective blinded comparative study is needed to provide valid evidence

  9. Multi-slice Fractional Ventilation Imaging in Large Animals with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Xin, Yi; Profka, Harrilla; Rajaei, Jennia; Kadlecek, Stephen; Ishii, Masaru; Rizi, Rahim R.

    2012-01-01

    Noninvasive assessment of regional lung ventilation is of critical importance in quantifying the severity of disease and evaluating response to therapy in many pulmonary diseases. This work presents for the first time the implementation of a hyperpolarized (HP) gas MRI technique for measuring whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the RF pulse decay effect from ventilatory signal build-up in the airways, regional distribution of flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no inter-scan time delay during a breath-hold at the tail-end of the ventilation sequence. Analysis was performed to assess the multi-slice ventilation model sensitivity to noise, oxygen and number of flip angle images. The optimal α value was determined based on minimizing the error in r estimation; αopt = 5–6° for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27±0.09, 0.35±0.06, 0.40±0.04 for ventral, middle and dorsal slices, respectively, (excluding conductive airways r > 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. Results demonstrate the feasibility of measurements of fractional ventilation in large species, and provides a platform to address technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of human beings. PMID:22290603

  10. Clinical application of multislice spiral CT angiography in evaluation of anomalous vertebral artery

    International Nuclear Information System (INIS)

    Hua Rui; Liu Jun; Zhang Yu

    2008-01-01

    Objective: To evaluate the diagnostic value of 16-slice spiral computed tomography angiography (MSCTA) in evaluation of anomalous vertebral artery. Methods: MSCTA data from 32 patients with anomalous vertebral artery were retrospectively analyzed. Results: 22 cases had vertebral artery course variation (bended into the C 5 , C 4 or C 3 foramen transversarium), 7 cases had variation in the prevertebral segments of vertebral arteries, 15 patients had unilateral vertebral congenital stenosis, 1 case had double vertebral artery branch, 1 case had vertebral arterial fenestration, and 2 cases had vertebral artery in one side that did not converged upon basilar artery and unilateral vertebral artery formed basilar artery. Conclusion: MSCTA is a useful noninvasive imaging tool for the diagnosis of vertebral artery variations. (authors)

  11. Computer aided detection system for Osteoporosis using low dose thoracic 3D CT images

    Science.gov (United States)

    Tsuji, Daisuke; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Harada, Masafumi; Kusumoto, Masahiko; Tsuchida, Takaaki; Eguchi, Kenji; Kaneko, Masahiro

    2018-02-01

    The patient of osteoporosis is about 13 million people in Japan and it is one of healthy life problems in the aging society. It is necessary to do early stage detection and treatment in order to prevent the osteoporosis. Multi-slice CT technology has been improving the three dimensional (3D) image analysis with higher resolution and shorter scan time. The 3D image analysis of thoracic vertebra can be used for supporting to diagnosis of osteoporosis. This analysis can be used for lung cancer detection at the same time. We develop method of shape analysis and CT values of spongy bone for the detection osteoporosis. Osteoporosis and lung cancer screening show high extraction rate by the thoracic vertebral evaluation CT images. In addition, we created standard pattern of CT value per thoracic vertebra for male age group using 298 low dose data.

  12. CT and MR imaging of the normal and pathologic conditions of the facial nerve

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, Lorenz E-mail: jaeger@ikra.med.uni-muenchen.de; Reiser, Maximilian

    2001-11-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are well established imaging modalities to examine the facial nerve as well as the course of the facial nerve itself. High spatial resolution is guaranteed not only in the x- and y-axis, but also in the z-axis using multislice spiral CT. With this technique, reformatted multiplanar images in oblique planes, avoiding additional examinations in the coronal plane, facilitate the delineation of the facial nerve canal. This is beneficial in patients with temporal bone trauma, malformation or osseous changes. MR has a superior soft-tissue contrast to CT that enables imaging of the facial nerve itself. Therefore the normal facial nerve as well as pathologic changes of the facial nerve is readily visualized from the brain stem to the parotid gland. This review article presents anatomy, pathology and imaging strategies in the diagnostics of the facial nerve.

  13. Continuously moving table MRI with sliding multislice for rectal cancer staging: Image quality and lesion detection

    International Nuclear Information System (INIS)

    Baumann, Tobias; Ludwig, Ute; Pache, Gregor; Fautz, Hans-Peter; Kotter, Elmar; Langer, Mathias; Schaefer, Oliver

    2010-01-01

    Purpose: To determine image quality and lesion detection of sliding multislice (SMS), a recently developed moving table MRI technique, in patients with rectal cancer. Materials and methods: Twenty-seven paired SMS (Avanto, Siemens Medical Solutions) and MDCT (Sensation 64, Siemens Medical Solutions) examinations of abdomen and pelvis were performed in patients with rectal cancer and compared for detection of liver, lymph node and bone metastases by two independent observers. A contrast-enhanced, fat saturated 2D gradient echo sequence (TE, 2.0 ms; TR, 102 ms; slice, 5 mm) was acquired with SMS and a standard contrast-enhanced protocol (100 ml 2.5 ml/s; slice, 5 mm) was used for abdominal MDCT. Standard of reference consisted of a consensus evaluation of SMS, MDCT, and all available follow-up examinations after a period of 6 months. Artifact burden and image quality of SMS was assessed in comparison to stationary gradient echo sequences obtained in an age-matched group of 27 patients. Results: Whereas SMS achieved a mean quality score of 3.65 (scale, 0-4) for the liver, representing very good diagnostic properties, strong breathing artifacts in the intestinal region were observed in 19 cases by both observers. The retroperitoneum still achieved a mean quality score of 3.52, although breathing artifacts were noted in 12 and 15 cases (observers 1 and 2, respectively). The sensitivities of SMS to detect hepatic metastases were 91.2% and 94.1% for both observers, respectively, compared to 98.5%/98.5% for MDCT. The sensitivities for lymph node metastases were 87.5%/81.3% for SMS compared to 78.1%/81.3% for MDCT. The sensitivities for bone metastases were 91.7%/100% for SMS compared to 8.3%/16.7% for MDCT. Conclusion: With slightly reduced image quality in the intestinal region, SMS exhibits equal detection of lymph node and liver metastases compared to MDCT. SMS MRI proved to be superior to MDCT in detection of bone metastases.

  14. Non invasive cardiac vein mapping: Role of multislice CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto, E-mail: robertomalag@yahoo.it [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Pezzato, Andrea; Barbiani, Camilla; Sala, Giuseppe; Zamboni, Giulia A. [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Tavella, Domenico [Cardiology Service, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Mucelli, Roberto Pozzi [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy)

    2012-11-15

    Purpose: Coronary venous anatomy is of primary importance when implanting a cardiac resynchronization therapy device, besides, the coronary sinus can be differently enlarged depending on chronic heart failure. The aim of this study is to evaluate the usefulness of Coronary CTA in describing the coronary venous tree and in particular the coronary sinus and detecting main venous system variants. Materials and methods: 301 consecutive patients (196 Male-Sign , mean age 63.74 years) studied for coronary artery disease with 64 slice Coronary CTA were retrospectively examined. The acquisition protocol was the standard acquisition one used for coronary artery evaluation but the cardiac venous system were visualized. The cardiac venous system was depicted using 3D, MPR, cMPR and MIP post-processing reconstructions on an off-line workstation. For each patient image quality, presence and caliber of the coronary sinus (CS), great cardiac vein (GCV), middle vein (MV), anterior interventricular vein (AIV), lateral cardiac vein (LCV), posterior cardiac vein (PCV), small cardiac vein (SCV) and presence of variant of the normal anatomy were examined and recorded. Results: CS, GCV, MV and AIV were visualized in 100% of the cases. The LCV was visualized in 255/301 (84%) patients, the PCV in 248/301 (83%) patients and the SCV in 69/301 (23%) patients. Mean diameter of the CS was 8.7 mm in 276/301 (91.7%) patients without chronic heart failure and 9.93 mm in 25/301 (8.3%) patients with chronic heart failure. Conclusions: Coronary CTA allows non invasive mapping of the cardiac venous system and may represent a useful presurgical tool for biventricular pacemaker devices implantation.

  15. Quantification of pulmonary emphysema in multislice-CT using different software tools

    International Nuclear Information System (INIS)

    Heussel, C.P.; Achenbach, T.; Buschsieweke, C.; Weinheimer, O.; Dueber, C.; Kuhnig, J.; Hammer, G.; Kauczor, H.U.

    2006-01-01

    Purpose: the data records of thin-section MSCT of the lung with approx. 300 images are difficult to use in manual evaluation. A computer-assisted pre-diagnosis can help with reporting. Furthermore, post-processing techniques, for instance, for quantification of emphysema on the basis of three-dimensional anatomical information might be improved and the workflow might be further automated. Materials and methods: the results of 4 programs (Pulmo registered , Volume registered , YACTA and PulmoFUNC) for the quantitative analysis of emphysema (lung and emphysema volume, mean lung density and emphysema index) of 30 consecutive thin-section MSCT datasets with different emphysema severity levels were compared. The classification result of the YACTA program for different types of emphysema was also analyzed. Results: Pulmo registered and Volume registered have a median operating time of 105 and 59 minutes respectively due to the necessity for extensive manual correction of the lung segmentation. The programs PulmoFUNC and YACTA, which are automated to a large extent, have a median runtime of 26 and 16 minutes, respectively. The evaluation with Pulmo registered and Volume registered using 2 different datasets resulted in implausible values. PulmoFUNC crashed with 2 other datasets in a reproducible manner. Only with YACTA could all graphic datasets be evaluated. The lung volume, emphysema volume, emphysema index and mean lung density determined by YACTA and PulmoFUNC are significantly larger than the corresponding values of Volume registered and Pulmo registered (differences: Volume registered : 119 cm 3 /65 cm 3 /1%/17 HU, Pulmo registered : 60 cm 3 /96 cm 3 /1 %/37 HU). Classification of the emphysema type was in agreement with that of the radiologist in 26 panlobular cases, in 22 paraseptalen cases and in 15 centrilobular emphysema cases. (orig.)

  16. Application of multislice spiral CT (MSCT) in multiple injured patients and its effect on diagnostic and therapeutic algorithms

    International Nuclear Information System (INIS)

    Boehm, T.; Alkadhi, H.; Schertler, T.; Baumert, B.; Roos, J.; Marincek, B.; Wildermuth, S.

    2004-01-01

    The initial diagnostic work-up of trauma victims with multiple injuries is currently a combination of conventional radiography (CR), ultrasound (US), and computed tomography (CT). This article reviews the diagnostic quality of the different imaging modalities regarding detection and classification of injuries. CT performs better than US in detecting traumatic lesions of abdominal parenchymal organs. Furthermore, CT is better than CR in detecting therapeutically relevant chest and bone injuries. MSCT may replace CR and US under the condition that it is faster than or at least as fast as the conventional approach to diagnose lite threatening injuries. This can be achieved only by changing the work-flow for the entire trauma team including radiologist. Furthermore, certain prerequisites must be fulfilled including integration of a MSCT scanner into the emergency room. An optimized whole body CT protocol for the assessment of trauma victims using MSCT as well as a two-step algorithm for reporting the imaging findings depending on their clinical significance is presented. (orig.)

  17. Quantitative assessment of pulmonary function using low dose multi-slice spiral CT in smoker

    International Nuclear Information System (INIS)

    Chen Huai; Zeng Qingsi; Zheng Jinping; Guan Yubao; Zhang Chaoliang; Cen Renli

    2012-01-01

    Objective: To evaluate the clinical feasibility of low dose MSCT for quantitative assessment of pulmonary function in smokers. Methods: One hundred and forty-six patients with chronic objective pulmonary disease (COPD) including 109 smokers (74.6%) and 37 non-smokers (25.3%) underwent pulmonary function test and low-dose MSCT scan. All data were analyzed using computer-aided lung analysis software. Pulmonary function parameters from low-dose MSCT were compared between smokers and non-smokers and also compared with pulmonary function test in non-smokers (Pearson test). Results: In smokers, the average volume at full inspiratory phase (Vin) was (5125 ± 862 ) ml, mean lung attenuation was (-902 ± 26) HU, mean lung density was (0.0984 ± 0.0260 ) g/cm 3 , emphysema volume was (2890 ±1370) ml. The average volume at full expiratory phase (Vex) was (2756 ±1027) ml, mean lung attenuation was (-811 ±62) HU, mean lung density was (0.1878 ±0.0631) g/cm 3 , emphysema volume was (685 ±104) ml. In non-smokers, the average Vin was (3734 ± 759) ml, mean lung attenuation was (-876 ±40) HU,mean lung density was (0.1244 ±0.0401)g/cm 3 , emphysema volume was ( 1503 ± 1217) ml. The average Vex was (1770 ± 679) ml, mean lung attenuation was (-765 ± 56) HU, mean lung density was (0.2360 ± 0.0563) g/cm 3 , emphysema volume was (156 ± 45) ml. There were significant differences between smokers and non-smokers (P<0.01). The Vex/Vin was correlated with residual volume/total lung capacity (RV/TLC, r=0.60, P<0.01), and Vin was correlated with TLC (r=0.58, P<0.01), Vex with RV (r=0.59, P<0.01). Pixel index (PI) -950 in was correlated with FEV 1% pre and FEV1/FVC% (r=-0.53, -0.62, respective, P<0.01), Pl-950ex was correlated with FEV1 % pre and FEV1/FVC% (r=-0.71, -0.77, respective, P<0.01). Conclusion: Low-dose MSCT can be a potential imaging tool for quantitative pulmonary function assessment in smokes. (authors)

  18. Blood flow patterns of solitary pulmonary nodules with enhancement: clinical value of multi-slice spiral CT

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Liu Huimin; Li Yuli; Li Huimin; Li Chengzhou; Zhang Chenshi; Tao Zhiwei; Yang Chunshan; Jiang Qingjun; Ouyang Lin; Yu Hong

    2004-01-01

    Objective: To evaluate the efficacy of dynamic multi-slice spiral computed tomography (MSCT) for providing quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs) and the correlation of vascular endothelial growth factor (VEGF)-positive tumor angiogenesis and the quantifiable parameters of blood flow pattern in solitary bronchogenic adenocarcinoma. Methods Seventy-eight patients with SPNs (with strong enhancement) (diameter ≤4 cm; 68 malignant; 10 active inflammatory) underwent multi-location dynamic contrast enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4 ml/s by using an autoinjector) serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion, peak height, and ratio of peak height of the SPN to that of the aorta were calculated. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. The quantifiable parameters (perfusion, peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta and mean transit time) of blood flow pattern in 30 VEGF-positive solitary bronchogenic adenocarcinoma were compared with microvessel densities (MVD) and VEGF expression by immunohistochemistry. Results: No statistically significant difference in the peak height was found between malignant (35.79 ± 10.76) HU and active inflammatory (39.76 ± 4.59) HU nodules (t=1.148, P=0.255). SPN-to-aorta ratio (14.27 ± 4.37)% and perfusion value (3.02 ± 0.96)ml -1 ·min -1 ·kg -1 in malignant SPNs were significantly lower than those of active inflammatory nodules(18.51 ± 2.71)%, (6.34 ± 4.39)ml -1 ·min -1 ·kg -1 (t=2.978, P=0.004, t=5.590, P -1 ·min -1 ·kg -1 , mean transit time (14.86 ± 5.84) s, and MVD (70.15 ± 20.03). Each of peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta, and perfusion correlated positively with MVD (r=0.781, P<0.0001; r=0

  19. Multi-slice spiral CT of the coronary arteries: improved vessel presentation by means of a standard software

    International Nuclear Information System (INIS)

    Schmitt, R.; Froehner, S.; Coblenz, G.; Christopoulos, G.; Brunn, J.; Mueller, M.; Kerber, S.; Fellner, F.

    2001-01-01

    Material and methods: Image data of 151 patients suffering from coronary artery disease were calculated by means of retrospective triggering at four different diastolic delay times in contrast-enhanced CT. The large coronary segments were subsequently reconstructed in two planes with multiplanar volume reconstruction (MPVR). Results: On the pre-condition that data sets were acquired at sinus rhythm and at a heart beat rate lower than 65/min coronary arteries could be depicted over a long distance in single or double angulated reconstruction planes with the help of MPVR. Time consumption for image reconstruction was reasonable. Additionally to the anatomy of the coronary arteries in two different planes, typical CT findings in occluding coronary artery disease are presented. (orig.) [de

  20. Imaging of Pericardiophrenic Bundles Using Multislice Spiral Computed Tomography for Phrenic Nerve Anatomy.

    Science.gov (United States)

    Wang, Yan-Jing; Liu, Lin; Zhang, Meng-Chao; Sun, Huan; Zeng, Hong; Yang, Ping

    2016-08-01

    Phrenic nerve injury and diaphragmatic stimulation are common complications following arrhythmia ablation and pacing therapies. Preoperative comprehension of phrenic nerve anatomy via non-invasive CT imaging may help to minimize the electrophysiological procedure-related complications. Coronary CT angiography data of 121 consecutive patients were collected. Imaging of left and right pericardiophrenic bundles was performed with volume rendering and multi-planar reformation techniques. The shortest spatial distances between phrenic nerves and key electrophysiology-related structures were determined. The frequencies of the shortest distances ≤5 mm, >5 mm and direct contact between phrenic nerves and adjacent structures were calculated. Left and right pericardiophrenic bundles were identified in 86.8% and 51.2% of the patients, respectively. The right phrenic nerve was phrenic nerve, phrenic nerve was phrenic nerve had a distance phrenic nerve showed a distance phrenic nerve anatomy, which might facilitate avoidance of the phrenic nerve-related complications in interventional electrophysiology. © 2016 Wiley Periodicals, Inc.

  1. Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

    International Nuclear Information System (INIS)

    Hui, Cheukkai; Suh, Yelin; Robertson, Daniel; Beddar, Sam; Pan, Tinsu; Das, Prajnan; Crane, Christopher H.

    2015-01-01

    Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt ins ) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt ins were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt ins was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt ins greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data

  2. Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

    Energy Technology Data Exchange (ETDEWEB)

    Hui, Cheukkai; Suh, Yelin [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Robertson, Daniel; Beddar, Sam, E-mail: abeddar@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Department of Radiation Physics, The University of Texas Graduate School of Biomedical Sciences, Houston, Texas 77030 (United States); Pan, Tinsu [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Department of Imaging Physics, The University of Texas Graduate School of Biomedical Sciences, Houston, Texas 77030 (United States); Das, Prajnan; Crane, Christopher H. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2015-07-15

    Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective

  3. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  4. The influence of respiratory motion on CT image volume definition

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Romero, Ruth, E-mail: rrromero@salud.madrid.org; Castro-Tejero, Pablo, E-mail: pablo.castro@salud.madrid.org [Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Puerta de Hierro Majadahonda, 28222 Madrid (Spain)

    2014-04-15

    Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath

  5. PET/CT和MSCT联合应用在孤立性肺结节诊断中的价值%PET-CT with multi-slice spiral CT in the diagnosis of SPN

    Institute of Scientific and Technical Information of China (English)

    汪世存; 方雷; 潘博; 展凤麟; 谢强; 谢吉奎

    2009-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射显像/电子计算机断层扫描成像(18F-deoxyglucose positron emission tomography /computer tomography 18F-FDG PET/CT)和多排CT( multi-slice spiral CT,MSCT)联合应用在孤立性肺结节(SPN)诊断中的价值.方法 87例SPN患者均行PET/CT及肺部病灶MSCT检查,影像诊断结果 与病理对照,进行统计分析.结果 87例SPN中,MSCT诊断正确64例,误诊23例,误诊率26.4%.PET/CT诊断正确70例,误诊17例,误诊率19.5%.MSCT和PET/CT联合诊断,80例诊断正确,7例误诊,误诊率8.0%.MSCT、PET/CT及两者联合诊断的敏感性、特异性和准确性分别为87.2%、68.1%、79.8%;89.5%、61.3%、81.4%和97.7%、74.2%、91.5%.MSCT和PET/CT单独诊断SPN的准确性无统计学意义(χ2=0.625,P=0.239),MSCT、PET/CT与两者联合应用诊断SPN的准确性均有统计学意义(χ2=7.762和5.318,P=0.005和0.021).结论 SPN的MSCT和PET/CT影像特征均有一定的重叠.单独采用MSCT或PET/CT诊断肺结节无明显统计学差异,MSCT和PET-CT协同诊断的准确性高于MSCT或PET/CT单独诊断.%Aim To evaluate the value of a combination of 18F-FDG PET-CT with multi-slice spiral CT in the diagnosis of SPN.Methods 18F-FDG PET-CT and multi-slice spiral CT were performed in 87 patients with SPN.The pathologically-proved findings were compared with findings diagnosed by MSCT and retrospectively analyzed.Results In 87 cases,the numbers of correct diagnosis and misdiagnosis with MSCT were 64 and 23 respectively,the misdiagnosis rate 26.4%,while the numbers of correct diagnosis and misdiagnosis with PET/CT were 70 and 17,the misdiagnosis rate 19.5%,but 50 cases were correctly diagnosed and 7 cases were misdiagnosed by combining 18F-FDG PET-CT with MSCT,the misdiagnosis rate 8.0%.The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of MSCT,PET/CT,and MSCT combined with PET /CT were 87.2%,68.1%,79.8%;89.5%,61.3%,81.4% and 97

  6. Image mottle in abdominal CT.

    Science.gov (United States)

    Ende, J F; Huda, W; Ros, P R; Litwiller, A L

    1999-04-01

    To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

  7. [Myocardial infarction as cause of an accident. The role of multislice CT in polytrauma management, differential diagnosis and insurance aspects].

    Science.gov (United States)

    Kleber, C; Oswald, B; Bail, H J; Haas, N P; Kandziora, F

    2008-12-01

    We present for the first time the use of contrast-enhanced multislice computed tomography in trauma care to detect acute myocardial infarction and verify it as the cause of a traffic accident. In addition to the case report, cardiac contusion, coronary dissection, and facets of insurance law are discussed. The determination of acute myocardial infarction, cardiac contusion, and coronary dissection can be challenging, but answers can be found in the medical history and accident details. The trauma surgeon in the emergency department must always be interested in clarifying the cause of trauma and keeping a secondary diagnosis in mind to strive for the goal of optimal and complete polytrauma care.

  8. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  9. The experimental study and clinical application on the detection of pulmonary nodules with low-dose multislice spiral CT

    International Nuclear Information System (INIS)

    Wu Xiaohua; Ma Daqing; Zhang Zhongjia; Ji Jingling; Zhang Yansong

    2004-01-01

    Objective: To investigate the detection rate of pulmonary nodules ,especially nodules ≤5 mm, in variable low-doses, and to evaluate the imaging quality of low-dose MSCT. Methods: Six postmortem specimens of patients with pneumoconiosis after necropsy were fixed at end-inspiratory volume. The fixed specimens were examined by using MSCT with standard dose (130 mA) and low-dose (50, 30, 10 mA, respectively). Low-dose MSCT scans of 40 asymptomatic volunteers and 60 patients with pulmonary metastasis were also examined with 30 mA. The numbers of pulmonary nodules less than 5 mm at standard-dose and different low-dose were recorded. Nodules were assessed by diagnostic confidence ('definite nodule', 'questionable nodule', and 'definite not nodule'). The number of images with artifact in specimens and in 40 volunteers and 60 patients with pulmonary metastasis were recorded. Results: In specimen's study, the Kappa values of groups of low-dose (50, 30, 10 mA) were 0.515, 0.242, and 0.154, respectively. The group of 50 mA had a good coincidence with standard-dose group by U test. The sensitivity of group 50, 30, 10 mA was 88.0%, 78.4%, and 75.0%, respectively. The positive predictive values of which were 98%, 94%, and 93%, respectively. The correction rates of which were 85%, 73%, and 69%, respectively. In specimens' images, subtle linear artifact was showed only in paravertebral lung field in 21 images of 31 at the group of 10 mA. Linear artifacts that affected small nodule detection were showed in lung apexes in 3 of 100 subjects. Conclusion: Low-dose MSCT is expected to improve early detection of lung cancer. Pulmonary nodules less than 5 mm could be reliably detected at 50 mA tube current in specimens. Low-dose CT (30 mA) showed satisfactory imaging quality in our study. Low-dose CT screening for lung cancer may be applied if situation permits. (authors)

  10. Functional Imaging: CT and MRI

    OpenAIRE

    van Beek, Edwin JR; Hoffman, Eric A

    2008-01-01

    Numerous imaging techniques permit evaluation of regional pulmonary function. Contrast-enhanced CT methods now allow assessment of vasculature and lung perfusion. Techniques using spirometric controlled MDCT allow for quantification of presence and distribution of parenchymal and airway pathology, Xenon gas can be employed to assess regional ventilation of the lungs and rapid bolus injections of iodinated contrast agent can provide quantitative measure of regional parenchymal perfusion. Advan...

  11. Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT

    Science.gov (United States)

    Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.

    1993-07-01

    We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.

  12. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  13. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (''ECG pulsing''): phantom measurements

    International Nuclear Information System (INIS)

    Poll, L.W.; Cohnen, M.; Brachten, S.; Moedder, U.; Ewen, K.

    2002-01-01

    To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. Material and methods: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5 mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-Thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ('ECG pulsing') at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of 'ECG pulsing'. Results: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5-1.8 mSv to 1.8-2.1 mSv, using the 2.5 mm collimation, and from 4.6-5.6 mSv to 5.9-7.2 mSv, for protocols using 1 mm collimation. Conclusions: The ECG-controlled tube current modulation allows a dose reduction of 37% to 44% when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate. (orig.) [de

  14. The multislice CT findings of renal carcinoma associated with XP11.2 translocation/TFE gene fusion and collecting duct carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Qingqiang; Zhu Wenrong; Chen Wenxin; Wu Jingtao [Subei People' s Hospital, Clinical School of Medical Coll., Yangzhou (China)], e-mail: wujingtaodoctor@163.com; Wang Zhongqiu [Dept. of Radiology, East Hospital, Tongji Univ. School of Medicine, Shanghai (China)

    2013-04-15

    Background: Renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusion (Xp11.2/TFE RCC), and collecting duct carcinoma (CDC) are uncommon subtypes of renal cell carcinomas. Purpose: To investigate the multislice CT (MSCT) characteristics of these two tumor types. Material and Methods Nine patients with Xp11.2/TFE RCC and 10 patients with CDC were studied retrospectively. MSCT was undertaken to investigate differences in tumor characteristics and enhancement patterns. Results: All patients had single tumors centered in the renal medulla. Two patients with each tumor type had lymph node involvement and there was a single case of hepatic metastasis (Xp11.2/TFE RCC). The mean tumor diameter of Xp11.2/TFE RCC tumors was significantly larger than for CDC tumors. Two patients with Xp11.2/TFE RCC had cystic components as did eight patients with CDC (P < 0.05). Calcifications were present in six patients, each with CDC. Clear tumor boundaries were visible in two patients with CDC and in nine with Xp11.2/TFE RCC (P < 0.05). The density of Xp11.2/TFE RCC tumors was greater than that of CDC tumors, normal renal cortex, or medulla on unenhanced CT. Enhancement was higher with Xp11.2/TFE RCC than with CDC tumors during all phases. Xp11.2/TFE RCC enhancement was higher than in the renal medulla during cortical and medullary phase but lower than in normal renal medulla during the delayed phase. CDC tumor enhancement was lower than that for normal renal medulla during all enhanced phases. Conclusion: Both tumor types originated from the renal medulla. Distinguishing features included density on unenhanced CT, enhancement patterns, and capsule signs. Identifying these differences may aid diagnosis.

  15. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Avsever, Hakan; Özdemir, Tayfun

    2013-12-01

    The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study. Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA). Radiographic and subjective bone quality classification (BQC) was also classified. Results were analyzed by correlation tests and multiple regressions (p < .05). CBCT-based gray density values (765 ± 97.32 voxel value) outside the implants were significantly higher than those of CT-based values (668.4 ± 110 Hounsfield unit, p < .001). Significant relations were found among the gray density values outside the implants, ITV (adjusted r(2)  = 0.6142, p = .001 and adjusted r(2)  = 0.5166, p = .0021), and RFA (adjusted r(2)  = 0.5642, p = .0017 and adjusted r(2)  = 0.5423, p = .0031 for CT and CBCT groups, respectively). Data from radiographic and subjective BQC were also in agreement. Similar to the gray density values of CT, that of CBCT could also be predictive for the subjective BQC and primary implant stability. Results should be confirmed on different CBCT scanners. © 2012 Wiley Periodicals, Inc.

  16. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    International Nuclear Information System (INIS)

    Liang Xin; Lambrichts, Ivo; Sun Yi; Denis, Kathleen; Hassan, Bassam; Li Limin; Pauwels, Ruben; Jacobs, Reinhilde

    2010-01-01

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm. Results: The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively. Conclusion: The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.

  17. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  18. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  19. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  20. The relationship between the peripheral lung cancer and the bronchi, pulmonary artery and vein: a multislice helical CT observation

    International Nuclear Information System (INIS)

    Liu Xueguo; Liang Mingzhu; Chen Cuifen; Qin Peixin; Zhong Guomei; He Yanguo; Liu Xiaobing; Han Mingqun; Yi Xianping; Wang Yong; Zhang Hao

    2008-01-01

    Objective: To investigate the relationships between the peripheral lung cancer and pulmonary vessels or bronchi by 16-row multislice computed tomography (MSCT) and analyze the related factors. Methods: Fifty-four patients with peripheral lung cancer confirmed pathologically underwent contrast-enhanced MSCT. Multiplanar reformation (MPR) and maximum intensity projection (MIP) in all patients were used to demonstrate the relationships between the peripheral lung cancer and pulmonary vessels, bronchi. The relationships were categorized five types: Type 1, erupted at the edge of nodule. Type 2, erupted at the center of nodule. Type 3, penetrated through the nodule. Type 4, contacting the nodule but stretched or encased. Type 5, contacting the nodule but smoothly compressed. The pathology type, stage, size, density and location of the peripheral lung cancer were recorded and the relationships with five types were evaluated by using Chi-square test and correlation analysis. Results: (1) Tumor-bronchi relationship: type 1 (33,61.1%) was more often seen in ≥2.0 cm and solid lesions with stage II-IV, while Type 2(14,25.9%) was often seen in < 2.0 cm and part-solid or non-solid lesions with stage I. (2) Tumor-PA relationship: Type 1 was more often seen in ≥2.0 cm and solid lesions with stage II-IV, while Type 2 was often seen in part-solid or non-solid lesions with stage I. (3) Tumor-PV relationship: type 4 was the most common type (29, 53.7%). Type 2 (13, 24.1%) was more often seen in part-solid or non-solid lesions. (4) Tumor-bronchi relationship and tumor-PA relationship had a positive correlation (r0.5265, P<0.01). Conclusions: MSCT can demonstrate the relations between the peripheral lung cancer and bronchi, PA and PV. It is useful for the differential diagnosis and prognosis evaluation of the lung cancer. (authors)

  1. Visualisation of animal anatomy using MRI and CT

    DEFF Research Database (Denmark)

    Lauridsen, Henrik; Hansen, Kasper; Pedersen, Michael

    imaging (MRI) and CT. Various species (tarantula, horseshoe crab, carp, haddock, lungfish, axolotl) were subjected to multi-slice MRI and CT protocols to produce 2D images of body slices, followed by volume rendering producing 3D digital models of animal anatomy with applications for visualising specific...

  2. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2012-01-01

    This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...... on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...

  4. Clinical feasibility of simultaneous multi-slice imaging with blipped-CAIPI for diffusion-weighted imaging and diffusion-tensor imaging of the brain.

    Science.gov (United States)

    Yokota, Hajime; Sakai, Koji; Tazoe, Jun; Goto, Mariko; Imai, Hiroshi; Teramukai, Satoshi; Yamada, Kei

    2017-12-01

    Background Simultaneous multi-slice (SMS) imaging is starting to be used in clinical situation, although evidence of clinical feasibility is scanty. Purpose To prospectively assess the clinical feasibility of SMS diffusion-weighted imaging (DWI) and diffusion-tensor imaging (DTI) with blipped-controlled aliasing in parallel imaging for brain lesions. Material and Methods The institutional review board approved this study. This study included 156 hyperintense lesions on DWI from 32 patients. A slice acceleration factor of 2 was applied for SMS scans, which allowed shortening of the scan time by 41.3%. The signal-to-noise ratio (SNR) was calculated for brain tissue of a selected slice. The contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated in 36 hyperintense lesions with a diameter of three pixels or more. Visual assessment was performed for all 156 lesions. Tractography of the corticospinal tract of 29 patients was evaluated. The number of tracts and averaged tract length were used for quantitative analysis, and visual assessment was evaluated by grading. Results The SMS scan showed no bias and acceptable 95% limits of agreement compared to conventional scans in SNR, CNR, and ADC on Bland-Altman analyses. Only FA of the lesions was higher in the SMS scan by 9% ( P = 0.016), whereas FA of the surrounding tissues was similar. Quantitative analysis of tractography showed similar values. Visual assessment of DWI hyperintense lesions and tractography also resulted in comparable evaluation. Conclusion SMS imaging was clinically feasible for imaging quality and quantitative values compared with conventional DWI and DTI.

  5. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  6. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  7. The measurement of organic radiation dose of multi-slice CT scanning by using the Chinese anthropomorphic chest phantom

    International Nuclear Information System (INIS)

    Peng Gang; Zeng Yongming; Luo Tianyou; Zhao Feng; Zhang Zhiwei; Yu Renqiang; Peng Shengkun

    2011-01-01

    Objective: Using the Chinese anthropomorphic chest phantom to measure the absorbed dose of various tissues and organs under different noise index, and to assess the radiation dose of MSCT chest scanning with the effective dose (ED). Methods: The equivalence of the Chinese anthropomorphic chest phantom (CDP-1 C) and the adult chest on CT sectional anatomy and X-ray attenuation was demonstrated. The absorbed doses of various tissues and organs under different noise index were measured by laying thermoluminescent dosimeters (TLD) inside the phantom, and the corresponding dose-length products (DLP) were recorded. Both of them were later converted into ED and comparison was conducted to analyze the dose levels of chest CT scanning with automatic tube current modulation (ATCM) under different noise index. Student t-test was applied using SPSS 12.0 statistical software. Results: The Phantom was similar to the human body on CT sectional anatomy. The average CT value of phantom are - 788.04 HU in lung, 45.64 HU in heart, 65.84 HU in liver, 254.32 HU in spine and the deviations are 0.10%, 3.04%, 4.49% and 4.36% respectively compared to humans. The difference of average CT value of liver was statistically significant (t=-8.705, P 0.05). As the noise index increased from 8.5 to 22.5, the DLP decreased from 393.57 mGy · cm to 78.75 mGy · cm and the organs dose declined. For example, the average absorbed dose decreased from 22.38 mGy to 3.66 mGy in lung. Compared to ED calculating by absorbed dose, the ED calculating by DLP was lower. The ED values of the two methods were 6.69 mSv and 8.77 mSv when the noise index was set at 8.5. Conclusions: Application of the Chinese anthropomorphic chest phantom to carry out CT dose assessment is more accurate. The noise index should be set more than 8.5 during the chest CT scanning based on ATCM technique. (authors)

  8. Panoramic three-dimensional CT imaging

    International Nuclear Information System (INIS)

    Kawamata, Akitoshi; Fujishita, Masami

    1998-01-01

    Panoramic radiography is a unique projection technique for producing a single image of both maxillary and mandibular arches and many other anatomical structures. To obtain a similar panoramic image without panoramic radiography system, a modified three-dimensional (3D) CT imaging technique was designed. A set of CT slice image data extending from the chin to the orbit was used for 3D reconstruction. The CT machine used in this study was the X-Vision (TOSHIBA, Japan). The helical scan technique was used. The slice thickness of reconstructed image was one or 1.5 mm. The occlusal plane or Frankfort horizontal (FH) plane was used as the reference line. The resultant slice image data was stored on a magnetic optical disk and then used to create panoramic 3D-CT images on a Macintosh computer systems (Power Macintosh 8600/250, Apple Computer Inc., USA). To create the panoramic 3D-CT image, the following procedure was designed: Design a curved panoramic 3D-CT imaging layer using the imaging layer and the movement of the x-ray beam in panoramic radiography system as a template; Cut this imaging layer from each slice image, then the trimmed image was transformed to a rectangular layer using the ''still image warping'' special effect in the Elastic Reality special effects system (Elastic Reality Inc., USA); Create panoramic 3D-CT image using the Voxel View (Vital Images Inc., USA) rendering system and volume rendering technique. Although the image quality was primitive, a panoramic view of maxillofacial region was obtained by this technique. (author)

  9. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    International Nuclear Information System (INIS)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun; Lan, Shen Yu

    2005-01-01

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses

  10. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun [Chonnam National University, Gwangju (Korea, Republic of); Lan, Shen Yu [Yan Bian Cancer Hospital, Peijing (China)

    2005-09-15

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses.

  11. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  12. Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-07-01

    The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic resonance scanner using a 15-channel knee coil. The EPI was performed at a b value of 500 s/mm2 without slice acceleration (conventional DTI) as well as with 2-fold and 3-fold acceleration. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in all 3 acquisitions. Fiber tracking performance was compared between the acquisitions regarding the number of tracks, average track length, and anatomical precision using multivariate analysis of variance and Mann-Whitney U tests. Acquisition time was 7:24 minutes for conventional DTI, 3:53 minutes for 2-fold acceleration, and 2:38 minutes for 3-fold acceleration. Overall FA and MD values ranged from 0.220 to 0.378 and 1.595 to 1.829 mm2/s, respectively. Two-fold acceleration yielded similar FA and MD values (P ≥ 0.901) and similar fiber tracking performance compared with conventional DTI. Three-fold acceleration resulted in comparable MD (P = 0.199) but higher FA values (P = 0.006) and significantly impaired fiber tracking in the soleus and tibialis anterior muscles (number of tracks, P DTI of skeletal muscle with similar image quality and quantification accuracy of diffusion parameters. This may increase the clinical applicability of muscle anisotropy measurements.

  13. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  14. Value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression

    Directory of Open Access Journals (Sweden)

    Ai-Jun Wu

    2016-12-01

    Full Text Available Objective: To study the value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression. Methods: A total of 135 patients with gastric cancer who received surgical resection in our hospital between May 2012 and October 2015 were selected as the research subjects, preoperative enhanced multi-slice spiral CT scan was conducted to judge TNM staging, and serum was collected to determine the content of tumor markers; tumor tissue was collected after operation to determine the content of cytokines and pro-proliferation molecules. Results: CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM II, III and IV stage gastric cancer were significantly higher than those of patients with TNM I stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM III and IV stage gastric cancer were significantly higher than those of patients with TNM II stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM IV stage gastric cancer were significantly higher than those of patients with TNM III stage. Conclusions: TNM staging of gastric cancer decided by preoperative enhanced multi-slice spiral CT scan has good consistency with the content of tumor markers in serum and proliferation molecules in tumor lesion.

  15. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.

    Science.gov (United States)

    Callot, Virginie; Duhamel, Guillaume; Cozzone, Patrick J; Kober, Frank

    2008-10-01

    Mouse spinal cord (SC) diffusion-weighted imaging (DWI) provides important information on tissue morphology and structural changes that may occur during pathologies such as multiple sclerosis or SC injury. The acquisition scheme of the commonly used DWI techniques is based on conventional spin-echo encoding, which is time-consuming. The purpose of this work was to investigate whether the use of echo planar imaging (EPI) would provide good-quality diffusion MR images of mouse SC, as well as accurate measurements of diffusion-derived metrics, and thus enable diffusion tensor imaging (DTI) and highly resolved DWI within reasonable scan times. A four-shot diffusion-weighted spin-echo EPI (SE-EPI) sequence was evaluated at 11.75 T on a group of healthy mice (n = 10). SE-EPI-derived apparent diffusion coefficients of gray and white matter were compared with those obtained using a conventional spin-echo sequence (c-SE) to validate the accuracy of the method. To take advantage of the reduction in acquisition time offered by the EPI sequence, multi-slice DTI acquisitions were performed covering the cervical segments (six slices, six diffusion-encoding directions, three b values) within 30 min (vs 2 h for c-SE). From these measurements, fractional anisotropy and mean diffusivities were calculated, and fiber tracking along the C1 to C6 cervical segments was performed. In addition, high-resolution images (74 x 94 microm(2)) were acquired within 5 min per direction. Clear delineation of gray and white matter and identical apparent diffusion coefficient values were obtained, with a threefold reduction in acquisition time compared with c-SE. While overcoming the difficulties associated with high spatially and temporally resolved DTI measurements, the present SE-EPI approach permitted identification of reliable quantitative parameters with a reproducibility compatible with the detection of pathologies. The SE-EPI method may be particularly valuable when multiple sets of images

  16. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  17. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  18. Noninvasive coronary artery imaging by multislice spiral computed tomography. A novel approach for a retrospectively ECG-gated reconstruction technique

    International Nuclear Information System (INIS)

    Sato, Yuichi; Kanmatsuse, Katsuo; Inoue Fumio

    2003-01-01

    Although the excellent spatial resolution of multislice spiral computed tomography (MSCT) enables the coronary arteries to be visualized, its limited temporal resolution results in poor image reproducibility because of cardiac motion artifact (CMA) and hence limits its widespread clinical use. A novel retrospectively electrocardiogram (ECG)-gated reconstruction method has been developed to minimize CMA. In 88 consecutive patients, the scan data were reconstructed using 2 retrospectively ECG-gated reconstruction methods. Method 1: the end of the reconstruction window (250 ms) was positioned at the peak of the P wave on ECG, which corresponded to the end of the slow filling phase during diastole immediately before atrial contraction. Method 2 (conventional method): relative retrospective gating with 50% referred to the R-R interval was performed so that the beginning of the reconstruction window (250 ms) was positioned at the halfway point between the R-R intervals of the heart cycle. The quality of the coronary artery images was evaluated according to the presence or absence of CMA. The assessment was applied to the left main coronary artery (LMCA), the left anterior descending artery (LAD, segments no.6, no.7, and no.8), the left circumflex artery (LCx, segments no.11 and no.13) and the right coronary artery (RCA, segments no.1, no.2 and no.3). The first diagonal artery (no.9-1), the obtuse marginal artery (no.12-1), the posterior descending artery (no.4-PD), the atrioventricular node branch (no.4-AV) and the first right ventricular branch (RV) were also evaluated. Of the 88 patients, 85 were eligible for image evaluation. Method 1 allowed visualization of the major coronary arteries without CMA in the majority of patients. The left coronary artery (LCA) system (segments no.5-7, no.11 and no.13) and the proximal portion of the RCA were visualized in more than 94% of patients. Artifact-free visualization of the distal portion of the LAD (segment no.8) and RCA (no.4

  19. Prevalence of Os Trigonum on CT Imaging

    NARCIS (Netherlands)

    Zwiers, Ruben; Baltes, Thomas P. A.; Opdam, Kim T. M.; Wiegerinck, Johannes I.; van Dijk, C. Niek

    2017-01-01

    The os trigonum is known as one of the main causes of posterior ankle impingement. In the literature, a wide variation of occurrence has been reported. All foot and/or ankle computed tomography (CT) scans made between January 2012 and December 2013 were reviewed. CT images were assessed, blinded for

  20. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  1. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  2. Multi-slice spiral CT multiplanar reconstruction findings of localized fat collection adjection to the subdiaphragmatic inferior vena cava

    International Nuclear Information System (INIS)

    Cao Hetao; Lu Jian; Zhao Jinli; Liu Tingting; Qin Jufeng; Xu Wen; Qin Jiangchun; Jiang Junkang

    2012-01-01

    Objective: To discusses the MSCT multiplanar reconstruction manifestation (MPR) of localized fat collection adjection to subdiaphragmatic inferior vena cava (IVC fat ). Methods: The thoracic and abdominal MSCT scan data of 8246 patients were browsed,45 patients with presumed IVC fat on axial CT scans were further studied prospectively with MSCT MPR. The predisposing position of IVC fat and its relationship with IVC were observed. It was divided into two kinds of intraluminal type and extraluminal type according to the angle of IVC fat with respect of the wall of IVC.The other 50 patients without IVC fat were randomly selected as the control group. The sagittal inclination angle (SIA) and diameter ratio (DR) between supra- and sub-diaphragmatic IVC between the two groups were compared by using t test. Results: The detection rate was 0.55% (45/8246). Of which hepatic vein lacuna 8 patients, subdiaphragmatic gap medial to IVC 28 patients and IVC groove 9 patients. The shape of IVC fat showed mainly for the round, oval and crescents on axial CT scans, of 15 patients intraluminal type, 4 showed 'target signs'. The shape of IVC fat showed mainly for 'half-moon' at MPR.The SIA and DR at IVC fat group were 21.62° ± 8.42° and 2.01 ±0.84 respectively, at control group were 16.75° ±7.82° (t=1.594, P>0.05) and 1.31 ±0.28 (t=2.341, P<0.05) respectively. Conclusion: The round, oval or half of limited fat density shadow adjection to subdiaphragmatic inferior vena cava which similar to in the lumen is the characteristic performance of IVC fat , it may be an anatomical variation. (authors)

  3. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  4. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  5. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  6. Three-dimensional reconstruction of CT images

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Toshiaki; Kattoh, Keiichi; Kawakami, Genichiroh; Igami, Isao; Mariya, Yasushi; Nakamura, Yasuhiko; Saitoh, Yohko; Tamura, Koreroku; Shinozaki, Tatsuyo

    1986-09-01

    Computed tomography (CT) has the ability to provide sensitive visualization of organs and lesions. Owing to the nature of CT to be transaxial images, a structure which is greater than a certain size appears as several serial CT images. Consequently each observer must reconstruct those images into a three-dimensional (3-D) form mentally. It has been supposed to be of great use if such a 3-D form can be described as a definite figure. A new computer program has been developed which can produce 3-D figures from the profiles of organs and lesions on CT images using spline curves. The figures obtained through this method are regarded to have practical applications.

  7. Study of low dose and dynamic multi-slice CT about obstructive sleep apnea syndrome in sleeping

    International Nuclear Information System (INIS)

    Shen Jie; Qi Ji; Yin Jianzhong

    2006-01-01

    Objective: To perform Low dose dynamic MSCT(multi-slice CT) in sleeping obstructive sleep apnea syndrome (OSAS) patients correcting the imprecise measure values in waking state, and to exactly analyse the location and extension of the dynamic changes about the condition. Methods: Sixteen OSAS patients were scanned both in waking and naturally sleeping period (end phase of inspiration and expiration). Measured at the narrowest part of the retropalatal (RP) and retroglossal (RG) and 5 mm under the tip of epiglottis at the epiglottal (EPG)at the end period of inspiration in sleeping, respectively, and compared the accurate position of the narrowest or occlusive level in 3 phases. All patients were also scanned using cine mode at the narrowest level at the end period of inspiration in sleeping to show the pharyngeal cavity changes during sleep. Results: The smallest XSA of RP region (M w =47.50 mm 2 , M e =73.00 mm 2 , M i =2.00 mm 2 ; Z we =2.897, P we =0.003; Z wi =4.192, P wi ie =4.538, P ie w =8.00 mm, M e =9.50 mm, M i =1.50 mm; Z we =1.933, P we =0.056; Z wi =3.720, P wi ie =4.230, P ie w =8.00 mm, M e =9.00 mm, M i =1.00 mm; Z we =1.210, P we =0.246; Z wi =4.203, P wi ie =4.557, P ie w =4.00 mm 3 , M e =5.50 mm 3 , M i =1.50 mm 3 ; Z we =1.576, P we =0.125; Z wi =3.532, P wi ie =4.077, P ie w =7.00 mm, M e =6.00 mm, M i =10.50 mm; Z we =0.557, P we =0.603; Z wi =2.541, P wi =0.011; Z ie =2.852, P ie =0.004) and RG regions (M w =5.00 mm, M e =3.00 mm, M i =9.50 mm; Z we =0.747, P we =0.482; Z wi =2.657, P wi =0.007; Z ie =3.075, P ie =0.001), were different between inspiration and expiration of sleeping or awake. The dynamic cine CT scan during sleeping could show pharyngeal change, clearly. Conclusion: At the end period of inspiration in sleeping, the location of narrow or obstructive of airway is the most precise and sensitive and the false negative at the waking could be obviously reduced. Low dose MSCT scan reduced exposure and expense. (authors)

  8. Modified CT imaging by reduction factor transformations

    International Nuclear Information System (INIS)

    Doehring, W.; Linke, G.

    1981-01-01

    The possibilities of CT image modification which had existed so far for given matrix of attenuation values (window setting, highlighting, black-and-white or colour reversal and logarithmic distortion of the video signal) are supplemented by the method of attenuation value transformation. As a specific case a linear interval by interval attenuation value transformation is described. First of all, the intirety of the measured CT values is transformed into the corresponding CT quotients (CTQ) and then subdivided into 5 optional intervals. Each one freely selected CTQ value can be allocated to the first and to the last interval; the intermediate 3 intervals can be linearly transformed at random. The article discusses the influence of such a manipulation on CT image reproduction; this is of particular importance for the image visualisation of the results of quantitative organ analyses by means of computed tomography. The presented paper also points to the possibility of effecting further attenuation value transformations. (orig.) [de

  9. Trial of quantitative analysis of cardiac function by 3D reconstruction of multislice cine MR images

    International Nuclear Information System (INIS)

    Yamamoto, Hideki; Sei, Tetsurou; Nakagawa, Tomio; Hiraki, Yoshio.

    1994-01-01

    Non-invasive techniques for measuring the dynamic behavior of the left ventricle (LV) can be invaluable tool in the diagnosis of the heart disease. In this paper we present methods for quantitative analysis of cardiac function using a compact magnetic resonance image processing system. A 256 x 256 magnetic resonance transaxial image of the left ventricle in a normal case is obtained. After gray level thresholding and region segmentation, the boundary of the left ventricular chamber is extracted. Then, the boundaries of the left ventricular chamber are displayed three-dimensionally by using the Z-buffer algorithm. Thus, LV volume and ejection fraction are calculated. Here, the value of LV ejection fraction is 60%. These results agree reasonably well with the corresponding data obtained by the echocardiography. (author)

  10. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Bhat, Himanshu; Runge, Val M; Guggenberger, Roman

    2016-06-01

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

  11. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  12. Pericardial sinuses and recesses effusion of 16-slice helical CT imaging and anatomic correlation

    International Nuclear Information System (INIS)

    Lu Chunyan; Yang Zhigang; Zhou Xiangping; Yu Jianqun; Zhu Jie; Yang Kaiqing

    2007-01-01

    Objective: To evaluate the CT features and implications of the pericardial sinuses and recesses effusion by combining the sectional cadavers and 16 multi-slice CT (MSCT) reformation. Methods: The anatomy and communication of the pericardial sinuses and recesses on the axial, coronal and saggital sectional cadavers (respectively 1 case), and the morphologic features on MSCT reformatted images in 104 patients were observed. The detection rate of effusion was analyzed. Results: The sectional cadavers and CT images showed that the pericardial sinuses and recesses were formed by the reflections of the pericardium on the root of the great vessels. The detection rate of the sinuses and recesses was lower in small effusion than in moderate and large effusion (P<0.05). The superior aortic recess was the most common recess for pericardial effusion. Conclusion: The MSCT reformatted images can show the morphologic features of pericardial sinuses and recesses effusion and communications with the pericardial cavity, help differentiate pericardial effusion from other mediastinal or pericardial lesions. (authors)

  13. Incidence of dehiscence of the bony roof of the superior semicircular canal by CT imaging

    International Nuclear Information System (INIS)

    Watanabe, Akira

    2003-01-01

    Dehiscence of the bony roof of the superior semicircular canal (SSCC) is rare, but it has been recognized by otologists since Minor et al first described superior canal dehiscence syndrome (SCDS). In this study, dehiscence of the bony roof of SSCC was incidentally detected in three patients with benign paroxysmal positional vertigo out of 49 serial patients with vertigo and dizziness by multi-slice computed tomography. Although detection of dehiscence of the SSCC by ultra-high-resolution CT imaging of the temporal bones has been required for a diagnosis of SCDS, this study showed that dehiscence of the bony roof of the SSCC can be an incidental finding and therefore is not specific for SCDS. (author)

  14. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  15. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  16. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  17. Research of ART method in CT image reconstruction

    International Nuclear Information System (INIS)

    Li Zhipeng; Cong Peng; Wu Haifeng

    2005-01-01

    This paper studied Algebraic Reconstruction Technique (ART) in CT image reconstruction. Discussed the ray number influence on image quality. And the adopting of smooth method got high quality CT image. (authors)

  18. What is the difference in the hybrid imaging techniques - SPECT/CT and PET-CT and is there any advantage of their application?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods - Single Photon Emission Tomography-Computer Tomography /SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET- CT - positron emitters are applied, most often 18F and 11C, while in SPECT-CT - single photon emitters, most often 99m Tc and 131 I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumor. As a final result, compared to the conventional techniques - roentgenography, CT and MRI, it is possible in many cases to make an early and more precise diagnosis, saving patients' time and using most appropriate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase. (author)

  19. Monte Carlo dose calibration in CT scanner

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.; Subbaiah, K.V.; Thayalan, K.

    2008-01-01

    Computed Tomography (CT) scanner is a high radiation imaging modality compared to radiography. The dose from a CT examination can vary greatly depending on the particular CT scanner used, the area of the body examined, and the operating parameters of the scan. CT is a major contributor to collective effective dose in diagnostic radiology. Apart from the clinical benefits, the widespread use of multislice scanner is increasing radiation level to patient in comparison with conventional CT scanner. So, it becomes necessary to increase awareness about the CT scanner. (author)

  20. General surface reconstruction for cone-beam multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Chen Laigao; Liang Yun; Heuscher, Dominic J.

    2003-01-01

    A new family of cone-beam reconstruction algorithm, the General Surface Reconstruction (GSR), is proposed and formulated in this paper for multislice spiral computed tomography (CT) reconstructions. It provides a general framework to allow the reconstruction of planar or nonplanar surfaces on a set of rebinned short-scan parallel beam projection data. An iterative surface formation method is proposed as an example to show the possibility to form nonplanar reconstruction surfaces to minimize the adverse effect between the collected cone-beam projection data and the reconstruction surfaces. The improvement in accuracy of the nonplanar surfaces over planar surfaces in the two-dimensional approximate cone-beam reconstructions is mathematically proved and demonstrated using numerical simulations. The proposed GSR algorithm is evaluated by the computer simulation of cone-beam spiral scanning geometry and various mathematical phantoms. The results demonstrate that the GSR algorithm generates much better image quality compared to conventional multislice reconstruction algorithms. For a table speed up to 100 mm per rotation, GSR demonstrates good image quality for both the low-contrast ball phantom and thorax phantom. All other performance parameters are comparable to the single-slice 180 deg. LI (linear interpolation) algorithm, which is considered the 'gold standard'. GSR also achieves high computing efficiency and good temporal resolution, making it an attractive alternative for the reconstruction of next generation multislice spiral CT data

  1. CT image registration in sinogram space.

    Science.gov (United States)

    Mao, Weihua; Li, Tianfang; Wink, Nicole; Xing, Lei

    2007-09-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy.

  2. CT image registration in sinogram space

    International Nuclear Information System (INIS)

    Mao Weihua; Li Tianfang; Wink, Nicole; Xing Lei

    2007-01-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy

  3. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  8. CT image in Reye syndrome

    International Nuclear Information System (INIS)

    Murayama, Takashi; Sakuma, Nobuko; Ishikawa, Akashi; Saito, Yoko; Takebayashi, Takeyasu; Kuwashima, Shigeru

    1983-01-01

    In a male infant with infantile spasms which had been observed, Reye's syndrome occurred at the age of 1 year and 6 months. CT findings, before the onset of Reye's syndrome, in the acute stage of the disease, and in the recovering stage, were obtained. The features of the disease were shown as low-absorption areas in the frontal and fronto-temporal areas of the head, and also strongly degenerative findings in the same areas, even in the recovery stage. This seemed to be characteristic to Reye's syndrome, and the basis of the suggestion was discussed. (Ueda, J.)

  9. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Runge, Val M.; Guggenberger, Roman [University Hospital of Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Piccirelli, Marco [University Hospital of Zurich, Department of Neuroradiology, Zurich (Switzerland); Bhat, Himanshu [Siemens Medical Solutions USA Inc, Charlestown, MA (United States)

    2016-06-15

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm{sup 2}; 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm{sup 2}/s; twofold acceleration: 1.016 ± 0.123 mm{sup 2}/s; threefold acceleration: 0.979 ± 0.153 mm{sup 2}/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. (orig.)

  10. The application and value of 64 multislice spiral CT of left atrium and pulmonary vein in radio-frequency ablation of atrial fibrillation

    International Nuclear Information System (INIS)

    Guo Xi; Lv Biao; Zhang Zhaoqi; Zhao Yike; Jiang Hong; Ma Changsheng; Yu Ronghui; Wang Xue; Cao Hainian

    2008-01-01

    Objective: Analyzing the left atrium and pulmonary vein morphologically by 64 multislice spiral CT (MSCT) scan to guide the catheter ablation of Atrial fibrillation. Methods: Two hundred and thirty-two patients (146 cases in atrial fibrillation group and 86 cases in control group) received 64 MSCT examination of the left atrium and pulmonary vein. The incidence of anatomical variation of pulmonary vein was compared between atrial fibrillation group and control group. For each group, the anatomical morphology of every pulmonary vein and the auricle of left atrium was analyzed, the diameter of the orifice of each pulmonary vein and the size of left atrium were measured. Results: Sixty-four MSCT of left atrium and pulmonary vein could demonstrate detailed connecting type between left atrium and pulmonary veins and the possible anatomical variation. Anatomical variation of pulmonary vein in this study accounted for 16.8% (39/232) of total sample. For both groups, orifices of pulmonary veins appeared oval and their superoinferior diameters were larger than their anteroposterior diameters. There was significant difference in the inner diameter of left atrium between atrial fibrillation group and control group [atrial fibrillation group: (39.47 ± 8.98) mm, control group: (36.94±5.49) mm, P=0.02], while there was no difference in the diameters of orifices of pulmonary veins between two groups [superoinferior diameters of pulmonary veins in atrial fibrillation group: left-up (18.15±1.35) mm, left-down (16.96±1.18) mm, right-up (17.50±1.12) mm, fight-down (17.65±0.94) mm, superoinferior diameters of pulmonary veins in control group: left-up (18.07±0.94) mm, left-down (17.50±0.57) mm, right-up (18.03±1.02) mm, fight-down (17.94±0.76) mm, the corresponding P>0.05, respectively, anteroposterior diameters of pulmonary veins in atrial fibrillation group: left-up (12.26±1.89) mm, left-down (11.96±0.61) mm, right-up (12.32± 1.08) mm, fight-down (12.39±0.95) mm

  11. Hybrid SPECT/CT imaging in neurology.

    Science.gov (United States)

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis.

  12. CT imaging of necrosive fasciitis

    International Nuclear Information System (INIS)

    Schulze, M.; Overkamp, D.; Joanoviciu, S.; Horger, M.

    2008-01-01

    NF is a rare but dramatic and often fatal infection of the fascii and adjoining soft tissues. Contrary to the Fournier's definition, it is most common in elderly people. Patients with immune problems have a higher risk (e.g. Diabetes mellitus, alcohol or drug abuse, AIDS, leukaemia, chemotherapy and immunosuppressive medication). Predisposition factors are diverticulitis, insect bites, or surgical interventions (Uppot RN, Levy HM, PLatel PH, Radiology 2003; 226; 115; Wysoki MG, Santora TA, Shah RM et al. Necrotizing fasciitis: CT characteristics, Radiology 1997; 203;859). Men are affected more frequently than women. In principle, NF may occur everywhere in the body but incidence in the region of the scrotum, perineum and lower extremities are the most common. (orig.)

  13. Fast parallel algorithm for CT image reconstruction.

    Science.gov (United States)

    Flores, Liubov A; Vidal, Vicent; Mayo, Patricia; Rodenas, Francisco; Verdú, Gumersindo

    2012-01-01

    In X-ray computed tomography (CT) the X rays are used to obtain the projection data needed to generate an image of the inside of an object. The image can be generated with different techniques. Iterative methods are more suitable for the reconstruction of images with high contrast and precision in noisy conditions and from a small number of projections. Their use may be important in portable scanners for their functionality in emergency situations. However, in practice, these methods are not widely used due to the high computational cost of their implementation. In this work we analyze iterative parallel image reconstruction with the Portable Extensive Toolkit for Scientific computation (PETSc).

  14. The effect of inspiration on airway dimensions measured in CT images from the Danish Lung Cancer Screening Trial

    DEFF Research Database (Denmark)

    Petersen, Jens; Wille, Mathilde; Thomsen, Laura

    2013-01-01

    of the same subject using image registration. Mixed effect models were used to predict the relative change in lumen diameter (LD) and wall thickness (WT) in airways of generation 0 (trachea) to 6 based on relative changes in the segmented total lung volume (TLV). Results: On average, 1.0, 2.0, 3.9, 7.6, 15...... and Materials: We selected from the Danish Lung Cancer Screening Trial 978 subjects without COPD who were scanned annually for 5 years with low-dose multi-slice CT. Using in-house developed software, the lungs and airways were automatically segmented and corresponding airway branches were found in all scans......Purpose: Airway dimensions measured from CT are increasingly being used to investigate diseases such as chronic obstructive pulmonary disease (COPD). In this study, we investigate the effect of differences in inspiration level on such measurements in voluntary inspiration breathhold scans. Methods...

  15. A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging.

    Science.gov (United States)

    De Cock, Jens; Zanca, Federica; Canning, John; Pauwels, Ruben; Hermans, Robert

    2015-07-01

    To evaluate image quality and radiation dose of a state of the art cone beam computed tomography (CBCT) system and a multislice computed tomography (MSCT) system in patients with sinonasal poliposis. In this retrospective study two radiologists evaluated 57 patients with sinonasal poliposis who underwent a CBCT or MSCT sinus examination, along with a control group of 90 patients with normal radiological findings. Tissue doses were measured using a phantom model with thermoluminescent dosimeters (TLD). Overall image quality in CBCT was scored significantly higher than in MSCT in patients with normal radiologic findings (p-value: 0.00001). In patients with sinonasal poliposis, MSCT scored significantly higher than CBCT (p-value: 0.00001). The average effective dose for MSCT was 42% higher compared to CBCT (108 μSv vs 63 μSv). CBCT and MSCT are both suited for the evaluation of sinonasal poliposis. In patients with sinonasal poliposis, clinically important structures of the paranasal sinuses can be better delineated with MSCT, whereas in patients without sinonasal poliposis, CBCT turns out to define the important structures of the sinonasal region better. However, given the lower radiation dose, CBCT can be considered for the evaluation of the sinonasal structures in patients with sinonasal poliposis. • CBCT and MSCT are both suited for evaluation of sinonasal poliposis. • Effective dose for MSCT was 42% higher compared to CBCT. • In patients with sinonasal poliposis, clinically important anatomical structures are better delineated with MSCT. • In patients with normal radiological findings, clinically important anatomical structures are better delineated with CBCT.

  16. CT imaging spectrum of infiltrative renal diseases.

    Science.gov (United States)

    Ballard, David H; De Alba, Luis; Migliaro, Matias; Previgliano, Carlos H; Sangster, Guillermo P

    2017-11-01

    Most renal lesions replace the renal parenchyma as a focal space-occupying mass with borders distinguishing the mass from normal parenchyma. However, some renal lesions exhibit interstitial infiltration-a process that permeates the renal parenchyma by using the normal renal architecture for growth. These infiltrative lesions frequently show nonspecific patterns that lead to little or no contour deformity and have ill-defined borders on CT, making detection and diagnosis challenging. The purpose of this pictorial essay is to describe the CT imaging findings of various conditions that may manifest as infiltrative renal lesions.

  17. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  18. Imaging of abdominal tumours: CT or MRI?

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.

    2009-01-01

    The scope of this review is to discuss a theoretical approach to imaging policy, particularly in the perspective of radiation risk reduction. Decisions are ideally driven by empirical evidence about efficacy and risk, e.g., in classical hierarchical efficacy model. As a result of the paucity of empirical evidence (inevitable because of rapid technological development), a pragmatic model is needed. This should avoid overemphasis of factors that currently seem to hamper change, namely personal preference, local expertise, infrastructure, availability. Extrapolation of current general knowledge about CT and MRI demonstrates how a pragmatic approach can be applied in the real world with intermediate goals such as (1) channeling patients from CT to MRI, and (2) reducing CT-delivered radiation. Increased utilisation of MRI in body imaging requires optimisation of scan protocols and equipment, and, being a very operator-dependent modality, the active involvement of the radiologist. In CT dose reduction the main challenge is to benchmark the minimum radiation-dose requirement, and therefore the minimum required image quality that is diagnostically acceptable. As this will ultimately depend on pre-test likelihoods in institutional populations, it is difficult to issue general guidance, and local assessment remains a cornerstone in this effort. (orig.)

  19. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  20. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  1. PET CT imaging: the Philippine experience

    International Nuclear Information System (INIS)

    Santiago, Jonas Y.

    2011-01-01

    Currently, the most discussed fusion imaging is PET CT. Fusion technology has tremendous potential in diagnostic imaging to detect numerous conditions such as tumors, Alzheimer's disease, dementia and neural disorders. The fusion of PET with CT helps in the localization of molecular abnormalities, thereby increasing diagnostic accuracy and differentiating benign or artefact lesions from malignant diseases. It uses a radiotracer called fluro deoxyglucose that gives a clear distinction between pathological and physiological uptake. Interest in this technology is increasing and additional clinical validation are likely to induce more health care providers to invest in combined scanners. It is hope that in time, a better appreciation of its advantages over conventional and traditional imaging modalities will be realized. The first PET CT facility in the country was established at the St. Luke's Medical Center in Quezon City in 2008 and has since then provided a state-of-the art imaging modality to its patients here and those from other countries. The paper will present the experiences so far gained from its operation, including the measures and steps currently taken by the facility to ensure optimum workers and patient safety. Plans and programs to further enhance the awareness of the Filipino public on this advanced imaging modality for an improved health care delivery system may also be discussed briefly. (author)

  2. CT Imaging of Craniofacial Fibrous Dysplasia

    Directory of Open Access Journals (Sweden)

    Zerrin Unal Erzurumlu

    2015-01-01

    Full Text Available Fibrous dysplasia is a benign fibroosseous bone dysplasia that can involve single (monostotic or multiple (polyostotic bones. Monostotic form is more frequent in the jaws. It is termed as craniofacial fibrous dysplasia, when it involves, though rarely, adjacent craniofacial bones. A 16-year-old girl consulted for a painless swelling in the right posterior mandible for two years. Panoramic radiography revealed ground-glass ill-defined lesions in the three different regions of the maxilla and mandible. Axial CT scan (bone window showed multiple lesions involving skull base and facial bones. Despite lesions in the skull base, the patient had no abnormal neurological findings. The lesion was diagnosed as fibrous dysplasia based on radiological and histopathological examination. In this paper, CT findings and differential diagnosis of CFD are discussed. CT is a useful imaging technique for CFD cases.

  3. CT technology update

    International Nuclear Information System (INIS)

    Edyvean, S.

    2004-01-01

    Full text: The capabilities of CT scanning as a diagnostic imaging medium increased dramatically with the introduction of four slice scanners in the second half of 1998. The ability to acquire four sets of scan projection data per revolution of the scanner gantry can be exploited by imaging a scan volume faster, or with greater z-axis resolution than a single slice scanner, or scanning larger volumes in the same total time. This has improved the quality of a number of clinical applications, as well as enabling new techniques that were not previously possible. This workshop will review the advances in CT scanning that have lead to modern multi-slice scanning. The operation of scanners will be explored looking at the hardware required and the changes in reconstruction techniques necessary with the higher number of imaged slices. The advantages and disadvantages of multi-slice scanners over their single-slice equivalents will be investigated, and image quality and dose issues will be discussed. An overview of the clinical applications that benefit from multi-slice technology will be given. The talk will end with a glimpse into the future where we have 64 and 256 slice, as well as flat panel, systems currently being trialled. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  4. Algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images

    International Nuclear Information System (INIS)

    Ogino, Takashi; Egawa, Sunao

    1991-01-01

    New algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images were developed. One, designated plane weighting method, is to correct CT value in proportion to the position of the beam element passing through the voxel. The other, designated solid weighting method, is to correct CT value in proportion to the length of the beam element passing through the voxel and the volume of voxel. Phantom experiments showed fair spatial resolution in the transverse direction. In the longitudinal direction, however, spatial resolution of under slice thickness could not be obtained. Contrast resolution was equivalent for both methods. In patient studies, the reconstructed radiotherapy simulation image was almost similar in visual perception of the density resolution to a simulation film taken by X-ray simulator. (author)

  5. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  6. Radiation protection in newer medical imaging techniques: Cardiac CT

    International Nuclear Information System (INIS)

    2008-01-01

    Medical imaging has seen many developments as it has evolved since the mid-1890s. In the last 30-40 years, the pace of innovation has increased, starting with the introduction of computed tomography (CT) in the early 1970s. During the last decade, the rate of change has accelerated further, in terms of continuing innovation and its global application. Most patient exposure now arises from practices that barely existed two decades ago. These developments are evident in the technology on which this volume is based - multislice/detector CT scanning and its application in cardiac imaging. However, this advance is achieved at the cost of a radiation burden to the individual patient, and possibly to the community, if its screening potential is exploited. Much effort will be required to ensure that the undoubted benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and an increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practices lag (inevitably) behind the industrial and clinical innovations. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice from experienced practitioners to bear on the problems involved. The advice in this report has been developed as part of the IAEA's statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were issued by the IAEA and co-sponsored by organizations including the Food and Agriculture

  7. Brain CT image and handedness of schizophrenia

    International Nuclear Information System (INIS)

    Hirose, Katsutoshi; Maehara, Katsuya; Iizuka, Reiji; Mikami, Akihiro.

    1989-01-01

    Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.)

  8. Radiation protection in newer medical imaging techniques: CT colonography

    International Nuclear Information System (INIS)

    2008-01-01

    Multislice/detector computed tomography (CT) scanning, applied to visualization of the colon in CT colonography (CTC), also known as virtual colonoscopy (VC), is a relatively new application of CT introduced in recent years. The possibility of its application in population screening techniques raises a number of questions. Effort is required to ensure that the benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and by an ever increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practice lag (inevitably) behind the industrial and clinical innovations being achieved. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice to bear on the problems involved. Under its statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for worldwide application of these standards, the IAEA has developed the Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). The BSS was issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and requires radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. The IAEA programme on radiation protection of patients encourages the reduction of patient doses without losing diagnostic benefits. To facilitate this

  9. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  10. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  11. Parallel CT image reconstruction based on GPUs

    International Nuclear Information System (INIS)

    Flores, Liubov A.; Vidal, Vicent; Mayo, Patricia; Rodenas, Francisco; Verdú, Gumersindo

    2014-01-01

    In X-ray computed tomography (CT) iterative methods are more suitable for the reconstruction of images with high contrast and precision in noisy conditions from a small number of projections. However, in practice, these methods are not widely used due to the high computational cost of their implementation. Nowadays technology provides the possibility to reduce effectively this drawback. It is the goal of this work to develop a fast GPU-based algorithm to reconstruct high quality images from under sampled and noisy projection data. - Highlights: • We developed GPU-based iterative algorithm to reconstruct images. • Iterative algorithms are capable to reconstruct images from under sampled set of projections. • The computer cost of the implementation of the developed algorithm is low. • The efficiency of the algorithm increases for the large scale problems

  12. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  13. Image reconstruction design of industrial CT instrument for teaching

    International Nuclear Information System (INIS)

    Zou Yongning; Cai Yufang

    2009-01-01

    Industrial CT instrument for teaching is applied to teaching and study in field of physics and radiology major, image reconstruction is an important part of software on CT instrument. The paper expatiate on CT physical theory and first generation CT reconstruction algorithm, describe scan process of industrial CT instrument for teaching; analyze image artifact as result of displacement of rotation center, implement method of center displacement correcting, design and complete image reconstruction software, application shows that reconstructed image is very clear and qualitatively high. (authors)

  14. Clinical PET/CT imaging. Promises and misconceptions

    International Nuclear Information System (INIS)

    Czernin, J.; Auerbach, M.A.

    2005-01-01

    PET/CT is now established as the most important imaging tool in oncology. PET/CT stages and restages cancer with a higher accuracy than PET or CT alone. The sometimes irrational approach to combine state of the art PET with the highest end CT devices should give way to a more reasonable equipment design tailored towards the specific clinical indications in well-defined patient populations. The continuing success of molecular PET/CT now depends more upon advances in molecular imaging with the introduction of targeted imaging probes for individualized therapy approaches in cancer patients and less upon technological advances of imaging equipment. (orig.)

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  16. 3D Interpolation Method for CT Images of the Lung

    Directory of Open Access Journals (Sweden)

    Noriaki Asada

    2003-06-01

    Full Text Available A 3-D image can be reconstructed from numerous CT images of the lung. The procedure reconstructs a solid from multiple cross section images, which are collected during pulsation of the heart. Thus the motion of the heart is a special factor that must be taken into consideration during reconstruction. The lung exhibits a repeating transformation synchronized to the beating of the heart as an elastic body. There are discontinuities among neighboring CT images due to the beating of the heart, if no special techniques are used in taking CT images. The 3-D heart image is reconstructed from numerous CT images in which both the heart and the lung are taken. Although the outline shape of the reconstructed 3-D heart is quite unnatural, the envelope of the 3-D unnatural heart is fit to the shape of the standard heart. The envelopes of the lung in the CT images are calculated after the section images of the best fitting standard heart are located at the same positions of the CT images. Thus the CT images are geometrically transformed to the optimal CT images fitting best to the standard heart. Since correct transformation of images is required, an Area oriented interpolation method proposed by us is used for interpolation of transformed images. An attempt to reconstruct a 3-D lung image by a series of such operations without discontinuity is shown. Additionally, the same geometrical transformation method to the original projection images is proposed as a more advanced method.

  17. Optimising imaging parameters in experimental spiral CT

    International Nuclear Information System (INIS)

    Tiitola, M.; Vehmas, T.; Kivisaari, R.P.; Kivisaari, L.

    1997-01-01

    Purpose: This in vitro study was conducted to analyse lesion detection and relative radiation exposure in different CT techniques. Material and Methods: We used a plastic phantom (12 x 8 x 2 cm) containing holes filled with air or fluid of varying densities to simulate lesions. This was imaged with Siemens Somatom Plus S and GE High Speed Advantage units. We varied table feeds (3 and 6 mm/s in Siemens and 3 and 4.5 mm/s in GE) and increments (2 mm and 4 mm) while keeping collimation at 3 mm. The SmartScan program of GE and the reformating algorithm of Siemens were also analysed. To evaluate the different methods, the phatnom lesions were counted by 3 observers. Radiation exposures associated with each technique were also measured. Results: The images reformatted to a coronal direction were significantly inferior (p<0.01) to those in other techniques. The use of SmartScan did not influence lesion detection, nor did changes in pitch or increment. Spiral and non-spiral techniques proved to be equal. Radiation exposure was lowest when a greater pitch or the SmartScan program was used. Conclusion: Radiation exposure in CT can be limited without significantly impairing the image quality by using low-dose techniques. Reformatting to a coronal direction should be used with care as it debases the image quality. (orig.)

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  6. Sexual difference of human hyoid bones. Quantitative analysis of CT three-dimensional image

    International Nuclear Information System (INIS)

    Terashima, Yoshiharu; Izumi, Masahiro; Hanamura, Hajime; Takada, Yasushi

    2007-01-01

    We investigated sexual differences in hyoid bones of 50 dissected Japanese cadavers: 26 males (aged 52 to 101, averaged 81.9 years) and 24 females (aged 61 to 94, averaged 83.6 years). All extracted hyoid bones were scanned by multi-slice CT. Length of body, distance between bilateral greater horns, length of greater horns, distance between bilateral lesser horns, and length of lesser horns were measured on CT three-dimensional image, and were analyzed by univariate and multivariate statistics. t-tests showed significant sexual differences in all the dimensions; being about 20% longer in males than in females. In principal component analysis using five hyoid dimensions, factor 1, expressing the overall size of the bone, fairly separated each sex, but factors 2 and 3, expressing the shape, did not. Discriminant analysis by a stepwise model, using all the eight dimensions, classified sex rightly (88.6% of the bone) by a function of two dimensions: length of body and distance between bilateral tips of lesser horns. In conclusion, a sexual difference of the hyoid bone was evident in size rather than in shape. (author)

  7. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  8. Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Comparison with angiographic results

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi; Matsumoto, Naoya; Kato, Masahiko [Nihon Univ., Tokyo (Japan). Surugadai Hospital] [and others

    2003-04-01

    The present study was designed to investigate the accuracy of multislice spiral computed tomography (MSCT) in detecting coronary artery disease, compared with coronary angiography (CAG), using a new retrospectively ECG-gated reconstruction method that reduced cardiac motion artifact. The study group comprised 54 consecutive patients undergoing MSCT and CAG. MSCT was performed using a SOMATOM Volume Zoom (4-detector-row, Siemens, Germany) with slice thickness 1.0 mm, pitch 1.5 (table feed: 1.5 mm per rotation) and gantry rotation time 500 ms. Metoprolol (20-60 mg) was administered orally prior to MSCT imaging. ECG-gated image reconstruction was performed with the reconstruction window (250 ms) positioned immediately before atrial contraction in order to reduce the cardiac motion artifact caused by the abrupt diastolic ventricular movement occurring during the rapid filling and atrial contraction periods. Following inspection of the volume rendering images, multiplanar reconstruction images and axial images of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) were obtained and evaluated for luminal narrowing. The results were compared with those obtained by CAG. Of 216 coronary arteries, 206 (95.4%) were assessable; 10 arteries were excluded from the analysis because of severe calcification (n=4), stents (n=3) or insufficient contrast enhancement (n=3). The sensitivity to detect coronary stenoses {>=}50% was 93.5% and the specificity to define luminal narrowing <50% was 97.2%. The positive predictive value and the negative predictive value were 93.5% and 97.2%, respectively. The sensitivity was still satisfactory (80.6%) even when non-assessable arteries were included in the analysis. The new retrospectively ECG-gated reconstruction method for MSCT has excellent diagnostic accuracy in detecting significant coronary artery stenoses. (author)

  9. Feature constrained compressed sensing CT image reconstruction from incomplete data via robust principal component analysis of the database

    International Nuclear Information System (INIS)

    Wu, Dufan; Li, Liang; Zhang, Li

    2013-01-01

    In computed tomography (CT), incomplete data problems such as limited angle projections often cause artifacts in the reconstruction results. Additional prior knowledge of the image has shown the potential for better results, such as a prior image constrained compressed sensing algorithm. While a pre-full-scan of the same patient is not always available, massive well-reconstructed images of different patients can be easily obtained from clinical multi-slice helical CTs. In this paper, a feature constrained compressed sensing (FCCS) image reconstruction algorithm was proposed to improve the image quality by using the prior knowledge extracted from the clinical database. The database consists of instances which are similar to the target image but not necessarily the same. Robust principal component analysis is employed to retrieve features of the training images to sparsify the target image. The features form a low-dimensional linear space and a constraint on the distance between the image and the space is used. A bi-criterion convex program which combines the feature constraint and total variation constraint is proposed for the reconstruction procedure and a flexible method is adopted for a good solution. Numerical simulations on both the phantom and real clinical patient images were taken to validate our algorithm. Promising results are shown for limited angle problems. (paper)

  10. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    Science.gov (United States)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Muhammad, H.; Sabarudin, A.; Ang, W. C.; Bahruddin, N. A.

    2016-03-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDIw (mGy), CTDIvol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDIvol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors.

  11. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    International Nuclear Information System (INIS)

    Karim, M K A; Hashim, S; Ang, W C; Bahruddin, N A; Bakar, K A; Muhammad, H; Sabarudin, A

    2016-01-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDI w (mGy), CTDI vol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDI vol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors. (paper)

  12. CT urethrography. New imaging technique of the urethra

    International Nuclear Information System (INIS)

    Takeyama, Nobuyuki; Munechika, Hirotsugu

    2005-01-01

    The purpose of the study is to assess the usefulness of CT urethrography for evaluation of the posterior urethra and surrounding structures. The CT images were performed with 4 channel multidetector row CT unit. Twenty-six cases (12 cases of CT urethrography and 14 cases of conventional urethrography) were included in this study. 3D-volume rendering (VR) images and VR-multiplaner reconstruction (MPR) sagittal images were compared with conventional retrograde urethrography (RUG) images to evaluate the following anatomical structures; the inferior wall of bladder, the neck of bladder, the posterior urethra, and the prostate. Two radiologists undertook a task of evaluation of the images. There was no significant difference in image quality between RUG and 3D-VR. However, VR-MPR sagittal images were significantly better than RUG or 3D-VR images in any anatomical structures set up beforehand for evaluation. CT urerthrography was useful for evaluation of the posterior urethra and surrounding structures. (author)

  13. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  14. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  15. Cirrhosis: CT and MR imaging evaluation

    International Nuclear Information System (INIS)

    Brancatelli, Giuseppe; Federle, Michael P.; Ambrosini, Roberta; Lagalla, Roberto; Carriero, Alessandro; Midiri, Massimo; Vilgrain, Valerie

    2007-01-01

    In this article, we present the CT and MR imaging characteristics of the cirrhotic liver. We describe the altered liver morphology in different forms of viral, alcoholic and autoimmune end-stage liver disease. We present the spectrum of imaging findings in portal hypertension, such as splenomegaly, ascites and varices. We describe the patchy and lacelike patterns of fibrosis, along with the focal confluent form. The process of hepatocarcinogenesis is detailed, from regenerative to dysplastic nodules to overt hepatocellular carcinoma. Different types of non-neoplastic focal liver lesions occurring in the cirrhotic liver are discussed, including arterially enhancing nodules, hemangiomas and peribiliary cysts. We show different conditions causing liver morphology changes that can mimic cirrhosis, such as congenital hepatic fibrosis, 'pseudo-cirrhosis' due to breast metastases treated with chemotherapy, Budd-Chiari syndrome, sarcoidosis and cavernous transformation of the portal vein

  16. Cirrhosis: CT and MR imaging evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brancatelli, Giuseppe [Sezione di Radiologia, Ospedale Specializzato in Gastroenterologia, ' Saverio de Bellis' -IRCCS, 70013 Castellana Grotte (Bari) (Italy) and Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy) and Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States)]. E-mail: gbranca@yahoo.com; Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States); Ambrosini, Roberta [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Lagalla, Roberto [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Carriero, Alessandro [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Midiri, Massimo [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Vilgrain, Valerie [Service de Radiologie, Hopital Beaujon, 100 Boulevard du General Leclerc, 92118 Clichy (France)

    2007-01-15

    In this article, we present the CT and MR imaging characteristics of the cirrhotic liver. We describe the altered liver morphology in different forms of viral, alcoholic and autoimmune end-stage liver disease. We present the spectrum of imaging findings in portal hypertension, such as splenomegaly, ascites and varices. We describe the patchy and lacelike patterns of fibrosis, along with the focal confluent form. The process of hepatocarcinogenesis is detailed, from regenerative to dysplastic nodules to overt hepatocellular carcinoma. Different types of non-neoplastic focal liver lesions occurring in the cirrhotic liver are discussed, including arterially enhancing nodules, hemangiomas and peribiliary cysts. We show different conditions causing liver morphology changes that can mimic cirrhosis, such as congenital hepatic fibrosis, 'pseudo-cirrhosis' due to breast metastases treated with chemotherapy, Budd-Chiari syndrome, sarcoidosis and cavernous transformation of the portal vein.

  17. Abdominal wall hernias: imaging with spiral CT

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G.

    2000-01-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  18. Neural network and its application to CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nikravesh, M.; Kovscek, A.R.; Patzek, T.W. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-02-01

    We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.

  19. An approach for quantitative image quality analysis for CT

    Science.gov (United States)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  20. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  1. Evaluation of the upper airway measurements by multi-slice CT before and after operations in obstructive sleep apnoea syndrome patients

    International Nuclear Information System (INIS)

    Tao Ping; Dang Yuqing; Chang Bei; Wang Xiao; Jin Zhengyu; Li Wuyi; Huo Hong

    2009-01-01

    Objective: To evaluate the changes of the upper airway of the patients with obstructive sleep apnoea syndrome (OSAS) before and after operations and to know the effects of operations by MSCT. Methods: The upper airway dimensions of 26 patients with OSAS were measured on multiplanar reformatted (MPR), curved-planar reformatted (CPR), volume rendering (VR) images of 16-slice spiral CT. The measurements include the anteroposterior calibres and the areas on the reformatted axial images on the pharyngeal cavity levels, the calibres and the minimum areas in retropalatal and retroglossal regions, the areas of the soft palate and uvula on the reformatted sagittal view with maximum thickness, the maximum wall thickness of the right and left the upper airway on the coronary images, the volume of the upper airway before and after the operations. The measurements were correlated with the polysomnography (PSG) records. The data were analyzed paired-samples t-test and Pearson correlations. Results: By comparison, the anteroposterior calibres and the cross-sectional areas on the reformatted axial view of the lower retropalatal region (slice 4) of the upper airway increased significantly after operations. The anteroposterior diameter increased from 5.9 mm before operations to 12.8 mm after operations, where t=-5.506, P 2 before operations to 275.0 mm 2 after operations, where t=-5.011, P 2 before operations to 128.0 mm 2 after operations, where t=3.087, P 2 before operation to 10.9 mm, 76.0 mm 2 after operation, where t=-3.413, -2.216, respectively and P 2 before operations to 76.0 mm 2 after operations, were t=-4.932, P<0.05. The anteroposterior calibres increased from 4.6 mm before operations to 6.6 mm after operations, where t=-7.308, P<0.05. The L-R calibres increased from 8.3 mm before operations to 13.6 mm after operations, where t=-4.320, P<0.05. Conclusions: MPR, CPR, VR of MSCT can evaluate the not only the morphology but the function changes of the upper airways on the

  2. Evaluation of Marfan syndrome: MR imaging versus CT

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fishman, E.K.; Pyeritz, R.E.; Gott, V.L.; Zerhouni, E.A.

    1986-01-01

    Twenty-five patients with Marfan, syndrome underwent both CT and MR imaging. MR imaging were interpreted in blinded fashion and then compared with CT scans MR imaging was found to be equivalent to CT in the detection of aortic, dural, and hip abnormalities in patients not operated on. MR imaging was superior to CT in the evaluation of postoperative patients because the artifact produced by Bjork-Shirley or St. Jude valves precludes adequate evaluation of the aortic root on CT while producing only a small inferior field distortion (a ''pseudo-ventricular septal defect'') on MR imaging. The absence of radiation exposure is another major advantage of MR imaging in this relatively young population requiring serial studies. The authors conclude that MR imaging is the modality of choice for the evaluation and follow-up of patients with Marfan syndrome and offers an appropriate means of screening their kindred

  3. CT Image Reconstruction in a Low Dimensional Manifold

    OpenAIRE

    Cong, Wenxiang; Wang, Ge; Yang, Qingsong; Hsieh, Jiang; Li, Jia; Lai, Rongjie

    2017-01-01

    Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a low-dimensional manifold model (LDMM) is investigated to characterize the low-dimensional patch manifold structure of natural images, where the manifold dimensionality characterizes structural information of an image. In this paper, we propose a CT image reconstruc...

  4. NMR-CT image and symbol phantoms

    International Nuclear Information System (INIS)

    Hongo, Syozo; Yamaguchi, Hiroshi; Takeshita, Hiroshi

    1990-01-01

    We have developed Japanese phantoms in two procedures. One is described as a mathematical expression. Another is 'symbol phantoms' in 3 dimensional picture-elements, each of which symbolize an organ name. The concept and the algorithm of the symbol phantom enables us to make a phantom for a individual in terms of all his transversal section images. We got 85 transversal section images of head and trunk parts, and those of 40 legs parts by using NMR-CT. We have made the individual phantom for computation of organ doses. The transversal section images were not so clear to identify all organs needed to dose estimation that we had to do hand-editing the shapes of organs with viewing a typical section images: we could not yet make symbol phantom in a automatic editing. Symbols were coded to be visual cords as ASCII characters. After we got the symbol phantom of the first stage, we can edit it easily using a word-processor. Symbol phantom could describe more freely the shape of organs than mathematical phantom. Symbol phantom has several advantages to be an individual phantom, but the only difficult point is how to determine its end-point as a reference man when we apply the method to build the reference man. (author)

  5. In vivo microCT imaging of rodent cerebral vasculature

    International Nuclear Information System (INIS)

    Seo, Youngho; Hasegawa, Bruce H; Hashimoto, Tomoki; Nuki, Yoshitsugu

    2008-01-01

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I tube x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml -1 at 1.2 ml min -1 ) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (∼85 μm) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels

  6. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  7. Biomedical Image Analysis: Rapid prototyping with Mathematica

    NARCIS (Netherlands)

    Haar Romenij, ter B.M.; Almsick, van M.A.

    2004-01-01

    Digital acquisition techniques have caused an explosion in the production of medical images, especially with the advent of multi-slice CT and volume MRI. One third of the financial investments in a modern hospital's equipment are dedicated to imaging. Emerging screening programs add to this flood of

  8. A study on optimal scan conditions of big bore multi-slice computed tomography based on radiation dose and image noise

    International Nuclear Information System (INIS)

    Lee, J. S.; Ye, S. J.; Kim, E. H.

    2011-01-01

    The newly introduced Big Bore computed tomography (CT) has a possibility to increase the tube current product scan time (mA s) for compensation of image degradation due to larger gentry opening without sound guideline. The objective of this paper is to derive optimal scan conditions for Big Bore CT scanner, mainly relating to the dose of diagnostic CT. The weighted CT dose index (CTDI w ) was estimated at five typical protocols, such as head and neck, brain, paediatric, chest and abdomen. Noises were analysed in a circle of 1 or 2 cm of diameter in CT image slice. The results showed that measured CTDI w values generally follow the theoretical rule at all scanning conditions of every protocol. Although image noises decrease with increment of mA s, analysed image noises do follow the theoretical rule, but only in specific protocols. This phenomenon is presumed to result from the photon energy spectra arriving at the detection system of the Big Bore scanner. (authors)

  9. MSCT在主动脉壁内血肿诊断和转归中的应用%Application of multi-slice spiral CT in diagnosis and prognosis of aortic artery intramural hematoma

    Institute of Scientific and Technical Information of China (English)

    黄源义; 谢欢; 邬正宏; 刘四斌

    2011-01-01

    Objective To investigate the applied value of multi-slice spiral CT in diagnosis and prognoses of aortic artery intramural hematoma(IMH). Methods 11 patients with IMH underwent plain CT scan and CT angiography with 16-slice spiral CT of GE. Endovascular stent for the treatment in 3 cases and conservative treatment in 8 cases was performed. All patients were followed-up twice or 4 times for 15 - 210 days(mean 112. 5 days). Results 3 cases with Stanford A and 8 cases with Stanford B IMH were diagnosed. The main CT findings were as follows: Crescent or circular thickening(>5 mm)of aortic wall with higher density or isodensi-ty without intimal flap as well as true and false lumen in 11 cases;atherosclerosis in 7 cases;intimal calcification ingression in 4 cases; intimal leakages in 3 cases;penetrating ulcer in 3 cases. The hematomas in 7 cases were completely absorbed,incomplete absorbed in 2 cases,while 2 cases were transformed to dissecting aneurysm. Conclusion MSCT is a significant method in diagnosis and follow-ing-up of IMH, and can provide important informations for clinical treatment.%目的 探讨MSCT在主动脉壁内血肿(IMH)诊断和转归中的应用价值.方法 采用GE 16排螺旋CT对11例IMH行平扫和CTA扫描.3例行腔内支架隔绝术,8例保守治疗.所有病例治疗后随访2~4次,随访时间15~210 d(平均112.5 d).结果 A型IMH 3例,B 型IMH 8例.MSCT主要征象为:11例主动脉壁新月形或环形增厚>5 mm,呈等密度或高密度,无内膜片撕裂及真、假两腔形成;主动脉粥样硬化7例;内膜钙化内移4例;内膜渗漏3例;穿透性溃疡3例.7例完全吸收,2例部分吸收,2例进展成夹层动脉瘤.结论 MSCT能对IMH作出明确的诊断,并可作为IMH随访的重要检查手段,对临床治疗有重要的指导意义.

  10. Measuring of the airway dimensions with spiral CT images: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huibin; Ma Ji; Wu Gang; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To measure the length, angle and their correlation of the main anatomical dimensions of the trachea and bronchus in experimental Japanese white big-ear rabbits with the help of spiral CT 3D images, in order to lay the foundation of treating the airway disorders with stenting in animal experiment. Methods: Multi-slice CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the longitudinal, transversal dimensions of the trachea, the glottis-carina length, the inner diameter and length of bronchi, and the angle formed by bronchial long axis and sagittal section were measured. Results: No significant difference was found in the inner diameters of various parts of the trachea and upper apical bronchi. The angle formed by bronchial long axis and sagittal section were smaller than that of the left ones. And the inner diameters of the right main bronchus was bigger than the left ones. Conclusion: The complex branching structure of the rabbit airway tree can be well displayed on spiral CT 3D images. Through measuring and statistical analysis of the results the authors have got a regressive equation for estimating the value of the inner diameter, length, angle, etc. concerning the airway tree, which is very helpful for providing the useful anatomical parameters in rabbit experiment. (authors)

  11. Analysis on the value of the multi-slice spiral CT and MRI scanning for applying to the identifying diagnosis of the new and old vertebral compresion fracture

    International Nuclear Information System (INIS)

    Huo Zhiyi; Gao Shuming; Li Dasheng; Pei Lijun; Qu Hui

    2008-01-01

    Objective: To analyze and explore the value of the mutislice spiral CT (MSCT) scanning, its reconstructive technology and MRI scanning for applying to the identifying diagnosis of new and old vertebral compresion fracture. Methods: One hundred and sixty-seven cases with the new and old vertebral compresion fracture who have 189 vertebrae in total were examined using the MSCT scanning, their imaging information were postprocessed with 2D and 3D reconstruction at the work station. Thirty-four patients with overall 43 vertebrae were carried out by MRI scanning and their images were compared with those of MSCT. Results: They had the highest proportion of vertebrae in L1 with accounting for 27.68% (31/112) and 35.06% (27/77) among the patients with new and old vertebral compresion fracture, respectively. The next was T12, L2 and T11. There were statistically significant differences between new and old cases in such appearance as fracture line clear and sharp (102 and 21), contusion and hemorrhage of spinal cord (15 and 0), parenchyma shadow beside vertebrae(103 and 11), appendant fracture(26 and 5), organ's lacerated wound around vertebral body (30 and 0), discus intervertebrales vacuum (10 and 36), derangement and hardening of vertebral bone trabecularism (29 and 51) (P 1 WI signal, 27 vertebrae with the T 2 WI fat-suppresion irregular high signal were demonstrated in MRI scanning among 27 vertebrae of 21 cases with new vertebral compresion fracture. While 16 vertebrae with the T 1 WI and T 2 WI signals were the same as those of the normal vertebrae, 16 vertebrae were the T 2 WI fat-suppresion low signal among 13 cases with old vertebral compresion fracture. Conclusions: The MSCT plays an important role in identifying diagnosis for the most of the patients with the new and old vertebral compresion fracture, while MRI scanning may reflect the pathophysiological characteristics in diagnosis of the spinal cord and the ligament lesion. Therefore, the MSCT and MRI scanning

  12. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  13. CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: marc.dewey@charite.de; Teige, Florian [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany); Rutsch, Wolfgang [Department of Cardiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: wolfgang.rutsch@charite.de; Schink, Tania [Department of Medical Biometry, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: peter.martus@charite.de; Hamm, Bernd [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)

    2008-07-15

    Purpose: To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). Materials and methods: For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. Results: Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p = 0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p < 0.05). The optimal combination consisted of 1.7 {+-} 0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). Conclusion: Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.

  14. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  15. Comparative study of single and multislice computed tomography for assessment of the mandibular canal

    Directory of Open Access Journals (Sweden)

    Adriana da Silva Ferreira Paes

    2007-06-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the accuracy of relative measurements from the roof of the mandibular canal to the alveolar crest in multislice (multidetector computed tomography (MDCT and single-slice computed tomography (SSCT. MATERIAL AND METHODS: The sample consisted of 26 printed CT films (7 SSCT and 19 MDCT from the files of the LABI-3D (3D Imaging Laboratory of the School of Dentistry of the University of São Paulo (FOUSP, which had been acquired using different protocols. Two observers analyzed in a randomized and independent order a series of 22 oblique CT reconstructions of each patient. Each observer analyzed the CT scans twice. The length of the mandibular canal and the distance between the mandibular canal roof and the crest of the alveolar ridge were obtained. Dahlberg test was used for statistical analysis. RESULTS: The mean error found for the mandibular canal length measurements obtained from SSCT was 0.53 mm in the interobserver analysis, and 0.38 mm for both observers. On MDCT images, the mean error was 0.0 mm in the interobserver analysis, and 0.0 and 0.23 mm in the intraobserver analysis. Regarding the distance between the mandibular canal roof and the alveolar bone crest, the SSCT images showed a mean error of 1.16 mm in the interobserver analysis and 0.66 and 0.59 mm in the intraobserver analysis. In the MDCT images, the mean error was 0.72 mm in the interobserver analysis and 0.50 and 0.54 mm in the intraobserver analysis. CONCLUSION: Multislice CT was demonstrated a more accurate method and demonstrated high reproducibility in the analysis of important anatomical landmarks for planning of mandibular dental implants, namely the mandibular canal pathway and alveolar crest height.

  16. Multi-slice Computed Tomography Appearance of Abscess of Cavum Septum Pellucidum: A Case Report and Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Vasudev, M.K.; Chavan, R.G.; Nagarajan, K.; Shukla, D.; Devi, B.I. [National Inst. of Mental Health and Neurosciences, Bangalore (India). Depts. of Neuroimaging and Interventional Radiology and of Neurosurgery

    2006-04-15

    Abscesses involving the cavum septum pellucidum are rare and, owing to their location, detection may be difficult with routine conventional computed tomography (CT). Only a few isolated cases have been reported and mostly in children. We report a case of abscess involving the cavum septum pellucidum in an adult and its appearance on multi-slice spiral CT Abscess, cavum septum pellucidum, multi-slice CT, surgery.

  17. CT and MR imaging of rhinocerebral mucormycosis

    International Nuclear Information System (INIS)

    Press, G.A.; Weindling, S.M.; Hesselink, J.R.

    1987-01-01

    Eight patients with biopsy-proven rhinocerebral mucormycosis had postcontrast CT. MR examination (1.5T) was also performed in two patients. Unilateral maxillary and ethmoid sinus disease with orbital apex extension was seen in five of six patients examined preoperatively. T2-weighted images showed intracranial extension as hyperintensity and mass effect in gray matter and white matter of frontal and temporal lobes, hypothalamus, thalamus, and pons in two patients. In the region of septic thrombosis of the cavernous sinus and internal carotid artery, MR detected inflammatory tissue of mixed signal intensity replacing the expected carotid signal void and petrous apex. Resolution of MR findings correlated with clinical improvement in one surviving patient

  18. Superiority of CT imaging reconstruction on Linux OS

    International Nuclear Information System (INIS)

    Lin Shaochun; Yan Xufeng; Wu Tengfang; Luo Xiaomei; Cai Huasong

    2010-01-01

    Objective: To compare the speed of CT reconstruction using the Linux and Windows OS. Methods: Shepp-Logan head phantom in different pixel size was projected to obtain the sinogram by using the inverse Fourier transformation, filtered back projection and Radon transformation on both Linux and Windows OS. Results: CT image reconstruction using the Linux operating system was significantly better and more efficient than Windows. Conclusion: CT image reconstruction using the Linux operating system is more efficient. (authors)

  19. Segmentation of liver tumors on CT images

    International Nuclear Information System (INIS)

    Pescia, D.

    2011-01-01

    This thesis is dedicated to 3D segmentation of liver tumors in CT images. This is a task of great clinical interest since it allows physicians benefiting from reproducible and reliable methods for segmenting such lesions. Accurate segmentation would indeed help them during the evaluation of the lesions, the choice of treatment and treatment planning. Such a complex segmentation task should cope with three main scientific challenges: (i) the highly variable shape of the structures being sought, (ii) their similarity of appearance compared with their surrounding medium and finally (iii) the low signal to noise ratio being observed in these images. This problem is addressed in a clinical context through a two step approach, consisting of the segmentation of the entire liver envelope, before segmenting the tumors which are present within the envelope. We begin by proposing an atlas-based approach for computing pathological liver envelopes. Initially images are pre-processed to compute the envelopes that wrap around binary masks in an attempt to obtain liver envelopes from estimated segmentation of healthy liver parenchyma. A new statistical atlas is then introduced and used to segmentation through its diffeomorphic registration to the new image. This segmentation is achieved through the combination of image matching costs as well as spatial and appearance prior using a multi-scale approach with MRF. The second step of our approach is dedicated to lesions segmentation contained within the envelopes using a combination of machine learning techniques and graph based methods. First, an appropriate feature space is considered that involves texture descriptors being determined through filtering using various scales and orientations. Then, state of the art machine learning techniques are used to determine the most relevant features, as well as the hyper plane that separates the feature space of tumoral voxels to the ones corresponding to healthy tissues. Segmentation is then

  20. An attenuation correction method for PET/CT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Yamazaki, Tomohiro; Haneishi, Hideaki

    2006-01-01

    In PET/CT systems, accurate attenuation correction can be achieved by creating an attenuation map from an X-ray CT image. On the other hand, respiratory-gated PET acquisition is an effective method for avoiding motion blurring of the thoracic and abdominal organs caused by respiratory motion. In PET/CT systems employing respiratory-gated PET, using an X-ray CT image acquired during breath-holding for attenuation correction may have a large effect on the voxel values, especially in regions with substantial respiratory motion. In this report, we propose an attenuation correction method in which, as the first step, a set of respiratory-gated PET images is reconstructed without attenuation correction, as the second step, the motion of each phase PET image from the PET image in the same phase as the CT acquisition timing is estimated by the previously proposed method, as the third step, the CT image corresponding to each respiratory phase is generated from the original CT image by deformation according to the motion vector maps, and as the final step, attenuation correction using these CT images and reconstruction are performed. The effectiveness of the proposed method was evaluated using 4D-NCAT phantoms, and good stability of the voxel values near the diaphragm was observed. (author)

  1. Interactive machine learning for postprocessing CT images of hardwood logs

    Science.gov (United States)

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2003-01-01

    This paper concerns the nondestructive evaluation of hardwood logs through the analysis of computed tomography (CT) images. Several studies have shown that the commercial value of resulting boards can be increased substantially if log sawing strategies are chosen using prior knowledge of internal log defects. Although CT imaging offers a potential means of obtaining...

  2. Importance of PET/CT for imaging of colorectal cancer

    International Nuclear Information System (INIS)

    Meinel, F.G.; Schramm, N.; Graser, A.; Reiser, M.F.; Rist, C.; Haug, A.R.

    2012-01-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has emerged as a very useful imaging modality in the management of colorectal carcinoma. Data from the literature regarding the role of PET/CT in the initial diagnosis, staging, radiotherapy planning, response monitoring and surveillance of colorectal carcinoma is presented. Future directions and economic aspects are discussed. Computed tomography (CT), magnetic resonance imaging (MRI) and FDG-PET for colorectal cancer and endorectal ultrasound for rectal cancer. Combined FDG-PET/CT. While other imaging modalities allow superior visualization of the extent and invasion depth of the primary tumor, PET/CT is most sensitive for the detection of distant metastases of colorectal cancer. We recommend a targeted use of PET/CT in cases of unclear M staging, prior to metastasectomy and in suspected cases of residual or recurrent colorectal carcinoma with equivocal conventional imaging. The role of PET/CT in radiotherapy planning and response monitoring needs to be determined. Currently there is no evidence to support the routine use of PET/CT for colorectal screening, staging or surveillance. To optimally exploit the synergy between morphologic and functional information, FDG-PET should generally be performed as an integrated FDG-PET/CT with a contrast-enhanced CT component in colorectal carcinoma. (orig.) [de

  3. Dual energy CT: New horizon in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Goo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  4. Dual-Energy CT: New Horizon in Medical Imaging.

    Science.gov (United States)

    Goo, Hyun Woo; Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  5. Accelerated Compressed Sensing Based CT Image Reconstruction.

    Science.gov (United States)

    Hashemi, SayedMasoud; Beheshti, Soosan; Gill, Patrick R; Paul, Narinder S; Cobbold, Richard S C

    2015-01-01

    In X-ray computed tomography (CT) an important objective is to reduce the radiation dose without significantly degrading the image quality. Compressed sensing (CS) enables the radiation dose to be reduced by producing diagnostic images from a limited number of projections. However, conventional CS-based algorithms are computationally intensive and time-consuming. We propose a new algorithm that accelerates the CS-based reconstruction by using a fast pseudopolar Fourier based Radon transform and rebinning the diverging fan beams to parallel beams. The reconstruction process is analyzed using a maximum-a-posterior approach, which is transformed into a weighted CS problem. The weights involved in the proposed model are calculated based on the statistical characteristics of the reconstruction process, which is formulated in terms of the measurement noise and rebinning interpolation error. Therefore, the proposed method not only accelerates the reconstruction, but also removes the rebinning and interpolation errors. Simulation results are shown for phantoms and a patient. For example, a 512 × 512 Shepp-Logan phantom when reconstructed from 128 rebinned projections using a conventional CS method had 10% error, whereas with the proposed method the reconstruction error was less than 1%. Moreover, computation times of less than 30 sec were obtained using a standard desktop computer without numerical optimization.

  6. Accelerated Compressed Sensing Based CT Image Reconstruction

    Directory of Open Access Journals (Sweden)

    SayedMasoud Hashemi

    2015-01-01

    Full Text Available In X-ray computed tomography (CT an important objective is to reduce the radiation dose without significantly degrading the image quality. Compressed sensing (CS enables the radiation dose to be reduced by producing diagnostic images from a limited number of projections. However, conventional CS-based algorithms are computationally intensive and time-consuming. We propose a new algorithm that accelerates the CS-based reconstruction by using a fast pseudopolar Fourier based Radon transform and rebinning the diverging fan beams to parallel beams. The reconstruction process is analyzed using a maximum-a-posterior approach, which is transformed into a weighted CS problem. The weights involved in the proposed model are calculated based on the statistical characteristics of the reconstruction process, which is formulated in terms of the measurement noise and rebinning interpolation error. Therefore, the proposed method not only accelerates the reconstruction, but also removes the rebinning and interpolation errors. Simulation results are shown for phantoms and a patient. For example, a 512 × 512 Shepp-Logan phantom when reconstructed from 128 rebinned projections using a conventional CS method had 10% error, whereas with the proposed method the reconstruction error was less than 1%. Moreover, computation times of less than 30 sec were obtained using a standard desktop computer without numerical optimization.

  7. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  8. Measurement of parapharyngeal space using CT images

    International Nuclear Information System (INIS)

    Ichimura, Keiichi; Kase, Yasuhiro; Iinuma, Toshitaka

    1991-01-01

    Parapharyngeal space can be defined as a potential space surrounded by deglutitional and masticator muscles and their covering, superficial and middle layer of deep cervical fascia. Parapharyngeal space has traditionally been divided by styloid process and fascia of tensor veli palatini muscle (nasopharyngeal level) or fascia of stylopharyngeus muscle (oropharyngeal level) into two compartments, prestyloid and poststyloid spaces. The latter is often called as carotid space. Prestyloid portion exclusively contains fat tissue, which yields hypoabsorption area in CT films and high density area in MRI. In most of papers in radiological journals, the term of parapharyngeal space is regarded as its prestyloid portion which is clearly identified. Axial CT images of 144 patients without any naso- or oropharyngeal lesions were analyzed. Two reference levels of nasopharynx were adopted for the study. The upper level passes through the plane of fossa of Rosenmuller, and the lower reference level transects soft palate. The following parameters of the space were measured; Length and width of the whole space, length and width of prestyloid fatty space, and furthermore, width of pre- and poststyloid space, that were divided by a imaginary line pararell to the axis of the whole space (the upper level); Length and width of the whole space, length of base and height of a triangle of the prestyloid part (the lower level). While parapharyngeal space was symmmetrical in the upper level, the rate of asymmetry amounted to a fourth in the lower level. Prestyloid space was broader than poststyloid one in the upper level. Men were dominant in length of the space in both the upper and the lower level and in length of the base of fatty space in the lower level. There was no difference between any age groups other than in fatty area in the lower level. Teens tended to be narrow, while 60's and older were wide. (author)

  9. Ring artifacts removal from synchrotron CT image slices

    International Nuclear Information System (INIS)

    Wei Zhouping; Chapman, Dean; Wiebe, Sheldon

    2013-01-01

    Ring artifacts can occur in reconstructed images from x-ray Computerized Tomography (CT) as full or partial concentric rings superimposed on the scanned structures. Due to the data corruption by those ring artifacts in CT images, qualitative and quantitative analysis of these images are compromised. In this paper, we propose to correct the ring artifacts on the reconstructed synchrotron radiation (SR) CT image slices. The proposed correction procedure includes the following steps: (1). transform the reconstructed CT images into polar coordinates; (2) apply discrete two-dimensional (2D) wavelet transform to the polar image to decompose it into four image components: low pass band image component, as well as the components from horizontal, vertical and diagonal details bands; (3). apply 2D Fourier transform to the vertical details band image component only, since the ring artifacts become vertical lines in the polar coordinates; (4). apply Gaussian filtering in Fourier domain along the abscissa direction to suppress the vertical lines, since the information of the vertical lines in Fourier domain is completely condensed to that direction; (5). perform inverse Fourier transform to get the corrected vertical details band image component; (6). perform inverse wavelet transform to get the corrected polar image; (7). transform the corrected polar image back to Cartesian coordinates to get the CT image slice with reduced ring artifacts. This approach has been successfully used on CT data acquired from the Biomedical Imaging and Therapy (BMIT) beamline in Canadian Light Source (CLS), and the results show that the ring artifacts in original SR CT images have been effectively suppressed with all the structure information in the image preserved.

  10. Multislice CT urography (MSCTU): evaluation of a modified scan protocol for optimized opacification of the collecting system; Mehrschicht-CT-Urographie (MSCTU): Beurteilung eines modifizierten Untersuchungsprotokolls zur Optimierung der Kontrastierung des Harnwegsystems

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Regier, M.; Stork, A.; Adam, G.; Nolte-Ernsting, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-05-15

    Purpose: To retrospectively quantify opacification of the urinary tract using a MSCTU protocol based on furosemide and individual adaptation of urographic acquisition delay. Materials and methods: MSCTU examinations obtained from 4-row and 16-row CT scanners in 53 patients (35 men, 18 women, average age 59) were independently reviewed by two radiologists. MSCTUs were performed using a low-dose injection of furosemide. No fixed scan delay for urographic image acquisition was applied. The urographic timing was individually adapted by performing low-dose test images of the distal ureters to display their current opacification. Image analysis included grading of the opacification of the segmented collecting system. The average urographic delay was calculated. Stratified comparisons of mean scores were assessed using the Friedman and Wilcoxon tests. The inter-observer kappa value was calculated. Results: The calculated median scan delay for patients with normal serum-creatinine levels (n=51) was 418 sec (mean 447 sec; SD, 118 sec). The median number of acquired test images was 2 (range 1-6 images). The opacification analysis demonstrated that 98% of the ICS, 90% of the proximal, 86% of the middle, and 83% of the distal ureteral segments showed opacification greater than 90%. 9.5% of the distal ureteral segments could not be visualized. Statistics did not show significant opacification differences between proximal, middle, and distal ureteral segments (p>0.05). The two observers were largely in agreement (kappa coefficient r=0.81). Conclusion: The analyzed MSCTU technique based on furosemide and scan delay timing by means of test images reliably lead to a homogeneous opacification of the entire upper urinary tract. It features the individual adaptation of MSCTU to the excretory rate of the kidneys. (orig.)

  11. CT and MRI techniques for imaging around orthopedic hardware

    Energy Technology Data Exchange (ETDEWEB)

    Do, Thuy Duong; Skornitzke, Stephan; Weber, Marc-Andre [Heidelberg Univ. (Germany). Dept. of Clinical Radiology; Sutter, Reto [Uniklinik Balgrist, Zurich (Switzerland). Radiology

    2018-01-15

    Orthopedic hardware impairs image quality in cross-sectional imaging. With an increasing number of orthopedic implants in an aging population, the need to mitigate metal artifacts in computed tomography and magnetic resonance imaging is becoming increasingly relevant. This review provides an overview of the major artifacts in CT and MRI and state-of-the-art solutions to improve image quality. All steps of image acquisition from device selection, scan preparations and parameters to image post-processing influence the magnitude of metal artifacts. Technological advances like dual-energy CT with the possibility of virtual monochromatic imaging (VMI) and new materials offer opportunities to further reduce artifacts in CT and MRI. Dedicated metal artifact reduction sequences contain algorithms to reduce artifacts and improve imaging of surrounding tissue and are essential tools in orthopedic imaging to detect postoperative complications in early stages.

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... best for your child. top of page Additional Information and Resources The Alliance for Radiation Safety in ...

  14. Reconstruction CT imaging of the hypopharynx and the larynx

    International Nuclear Information System (INIS)

    Okuno, Tetsuji; Fujimura, Akiko; Murakami, Yasushi; Shiga, Hayao

    1986-01-01

    The multiplanar reconstruction CT imaging of the hypopharynx and the larynx was performed on a total of 20 cases: 8 with laryngeal carcinomas, 6 with hypopharyngeal carcinomas, 4 with vocal cord paralyses due to various causes, 1 with laryngeal amyloidosis, 1 with inflammatory granuloma of the hypopharynx. Coronal, segittal, and parasagittal reconstruction images were obtained from either 1 or 2 mm overlapping axial scans with 4 or 5 mm slice thickness (3 cases) using 5 sec scan times during queit breathing. In 15 cases with coronal reconstruction imaging, the anatomical derangements of the laryngopharyngeal structures especially along the undersurface of the true vocal cord to the false cord level, the lateral wall of the pyriform sinus, and the paraglottic space were demonstrated more clearly than the axial CT imaging. In 5 cases with sagittal reconstruction imaging, the vertical extension of the lesions through the anterior commisure was more clearly depicted than the axial CT imaging. In 8 cases with parasagittal reconstruction imaging, which is along the vocal fold or across the aryepiglottic fold, pathological changes along the aryepiglottic fold, the arytenoid-corniculate cartilage complex, and the tip of the pyriform sinus were more clearly demonstrated than the axial CT imaging. In determining the feasibility of conservation surgery of the larynx and the hypopharynx, reconstruction CT imaging is recommended as the diagnostic procedure of a choice, which would supplement the findings of the routine axial CT imaging. (author)

  15. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  16. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    Science.gov (United States)

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  17. Dual scan CT image recovery from truncated projections

    Science.gov (United States)

    Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat

    2017-12-01

    There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.

  18. CT and MR imaging characteristics of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Ching, A.S.C.; Sun Canhui; Guo Huanyi; Fan Miao; Meng Quanfei; Li Ziping

    2010-01-01

    Aim: This study aims to analyze computed tomography (CT) and magnetic resonance (MR) imaging features of infantile hepatic hemangioendotheliomas before and after treatment. Materials and methods: CT and MR examinations of seven infants with biopsy proven hepatic hemangioendotheliomas were retrospectively analyzed. The distribution, number, size, imaging appearance, enhancement pattern and post-treatment changes of the tumors were evaluated. Results: A total of 153 hepatic hemangioendotheliomas were detected on CT (111) and MR (42) imaging. In six infants, 109/111 (98.2%) tumors were hypodense and 2/111 (1.8%) lesions contained calcification on unenhanced CT. On MR imaging, all 42 lesions in one infant were heterogeneously T1-hypointense and T2-hyperintense compared to the normal liver parenchyma. Contrast-enhanced CT and MRI showed peripheral rim (51.6%), uniform (48.4%), fibrillary (33.3%), and nodular (28.8%) contrast enhancement in the hepatic arterial phase. Homogeneous (100%), rim (98.2%) and mixed enhancement patterns were noted in tumors 2.0 cm and 1.0-2.0 cm in diameter respectively in the hepatic arterial phase. In three patients who underwent steroid therapy, follow-up CT examination demonstrated tumor size reduction and increased intra-tumoral calcification in two patients. Conclusion: Infantile hepatic hemangioendotheliomas show some typical imaging features and size-dependent pattern of contrast enhancement on CT and MR imaging, which allow accurate imaging diagnosis and post-treatment evaluation.

  19. Development of a 3-dimensional CT using an image intensifier

    International Nuclear Information System (INIS)

    Toyofuku, Fukai

    1992-01-01

    A prototype of three-dimensional CT (Fluoroscopic CT) has been developed using an image intensifier as a two-dimensional X-ray detector. A patient on a rotating table is projected onto an image intensifier by a cone beam of X-ray from the X-ray tube. A total of 390 projection images covering 180 degrees are acquired in a single scan (13 sec) and stored on a digital frame recorder (512 x 256 x 8-bit x 480). The transverse axial images are reconstructed by using the usual CT reconstruction algorithm, while longitudinal section images such as sagittal, coronal, oblique, and panoramic images are obtained by directly back-projecting the filtered projection image onto the sections. The radiation exposure was measured with an ionization chamber, and the exposure of the present fluoroscopic CT is about 10 to 20 times less than that of conventional X-ray CT. A similar monochromatic X-ray CT system has also been developed using synchrotron radiation. Large area parallel X-rays are obtained from a wiggler beam using a silicon crystal with [311] asymmetric reflection. By taking two images above and below iodine K-absorption edge (33.17 keV), iodine image is obtained. (author)

  20. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  1. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  2. CT myocardial perfusion imaging. Ready for prime time?

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P.; Celeng, Csilla [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Ashley River Tower, Heart and Vascular Center, Charleston, SC (United States)

    2018-03-15

    The detection of functional coronary artery stenosis with coronary CT angiography (CCTA) is suboptimal. Additional CT myocardial perfusion imaging (CT-MPI) may be helpful to identify patients with myocardial ischaemia in whom coronary revascularization therapy would be beneficial. CT-MPI adds incremental diagnostic and prognostic value over obstructive disease on CCTA. It allows for the quantitation of myocardial blood flow and calculation of coronary flow reserve and shows good correlation with {sup 15}O-H{sub 2}O positron emission tomography and invasive fractional flow reserve. In addition, patients prefer CCTA/CT-MPI over SPECT, MRI and invasive coronary angiography. CT-MPI is ready for clinical use for detecting myocardial ischaemia caused by obstructive disease. Nevertheless, the clinical utility of CT-MPI to identify ischaemia in patients with non-obstructive/microvascular disease still has to be established. (orig.)

  3. CT images of infantile viral encephalitis

    International Nuclear Information System (INIS)

    Sugimoto, Tateo; Okazaki, Hitoshi; Woo, Man

    1985-01-01

    Cranial CT scanning was undertaken in 40 patients with infantile viral encephalitis seen from 1977 to 1983. According to the pathogenic viruses, abnormal CT findings were detected most frequently in cases of herpes simplex encephalitis (HSE), followed by non-eruptive viral encephalitis, measles encephalitis, and rubella encephalitis in that order, which coincided well with neurological prognosis. Although CT findings lay within a normal range in cases of measles encephalitis, except a case in which cerebral ventricle was slightly dilated, the degree of consciousness disturbance was unfavorable and it persisted long. This revealed that there is no distinct correlation between the degree of consciousness disturbance and CT findings. Normal CT findings were detected in 13% of patients aged less than 5 years and 76.5% of patients aged 5 years or more. In many patients who had an attack of viral encephalitis at the age of 5 years or more, epileptic seizures occurred frequently, even though CT findings were normal. (Namekawa, K.)

  4. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink