WorldWideScience

Sample records for multiple-reaction monitoring mrm

  1. Multiple reaction monitoring (MRM)-profiling for biomarker discovery applied to human polycystic ovarian syndrome.

    Science.gov (United States)

    Cordeiro, Fernanda B; Ferreira, Christina R; Sobreira, Tiago Jose P; Yannell, Karen E; Jarmusch, Alan K; Cedenho, Agnaldo P; Lo Turco, Edson G; Cooks, R Graham

    2017-09-15

    We describe multiple reaction monitoring (MRM)-profiling, which provides accelerated discovery of discriminating molecular features, and its application to human polycystic ovary syndrome (PCOS) diagnosis. The discovery phase of the MRM-profiling seeks molecular features based on some prior knowledge of the chemical functional groups likely to be present in the sample. It does this through use of a limited number of pre-chosen and chemically specific neutral loss and/or precursor ion MS/MS scans. The output of the discovery phase is a set of precursor/product transitions. In the screening phase these MRM transitions are used to interrogate multiple samples (hence the name MRM-profiling). MRM-profiling was applied to follicular fluid samples of 22 controls and 29 clinically diagnosed PCOS patients. Representative samples were delivered by flow injection to a triple quadrupole mass spectrometer set to perform a number of pre-chosen and chemically specific neutral loss and/or precursor ion MS/MS scans. The output of this discovery phase was a set of 1012 precursor/product transitions. In the screening phase each individual sample was interrogated for these MRM transitions. Principal component analysis (PCA) and receiver operating characteristic (ROC) curves were used for statistical analysis. To evaluate the method's performance, half the samples were used to build a classification model (testing set) and half were blinded (validation set). Twenty transitions were used for the classification of the blind samples, most of them (N = 19) showed lower abundances in the PCOS group and corresponded to phosphatidylethanolamine (PE) and phosphatidylserine (PS) lipids. Agreement of 73% with clinical diagnosis was found when classifying the 26 blind samples. MRM-profiling is a supervised method characterized by its simplicity, speed and the absence of chromatographic separation. It can be used to rapidly isolate discriminating molecules in healthy/disease conditions by

  2. Accurate quantification of 5 German cockroach (GCr) allergens in complex extracts using multiple reaction monitoring mass spectrometry (MRM MS).

    Science.gov (United States)

    Mindaye, S T; Spiric, J; David, N A; Rabin, R L; Slater, J E

    2017-12-01

    German cockroach (GCr) allergen extracts are complex and heterogeneous products, and methods to better assess their potency and composition are needed for adequate studies of their safety and efficacy. The objective of this study was to develop an assay based on liquid chromatography and multiple reaction monitoring mass spectrometry (LC-MRM MS) for rapid, accurate, and reproducible quantification of 5 allergens (Bla g 1, Bla g 2, Bla g 3, Bla g 4, and Bla g 5) in crude GCr allergen extracts. We first established a comprehensive peptide library of allergens from various commercial extracts as well as recombinant allergens. Peptide mapping was performed using high-resolution MS, and the peptide library was then used to identify prototypic and quantotypic peptides to proceed with MRM method development. Assay development included a systematic optimization of digestion conditions (buffer, digestion time, and trypsin concentration), chromatographic separation, and MS parameters. Robustness and suitability were assessed following ICH (Q2 [R1]) guidelines. The method is precise (RSD  0.99, 0.01-1384 fmol/μL), and sensitive (LLOD and LLOQ MS, we quantified allergens from various commercial GCr extracts and showed considerable variability that may impact clinical efficacy. Our data demonstrate that the LC-MRM MS method is valuable for absolute quantification of allergens in GCr extracts and likely has broader applicability to other complex allergen extracts. Definitive quantification provides a new standard for labelling of allergen extracts, which will inform patient care, enable personalized therapy, and enhance the efficacy of immunotherapy for environmental and food allergies. © 2017 The Authors. Clinical & Experimental Allergy published by John Wiley & Sons Ltd. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  3. Rapid determination of eight bioactive alkaloids in Portulaca oleracea L. by the optimal microwave extraction combined with positive-negative conversion multiple reaction monitor (+/-MRM) technology.

    Science.gov (United States)

    Liang, Xiao; Tian, Jinlong; Li, Lingzhi; Gao, Jun; Zhang, Qingyi; Gao, Pinyi; Song, Shaojiang

    2014-03-01

    A rapid and reliable microwave extraction and the triple quadrupole-linear ion trap mass spectrometry method was developed and validated for the determination of eight alkaloids in Portulaca oleracea L. The optimal microwave extraction (MWE) condition was performed at 60 °C for 12 min with ethanol-water (70:30, v/v) as the extracting solvent, and the solvent to solid ratio was 30:1. The alkaloids were first detected simultaneously by electrospray ionization tandem mass spectrometry under positive-negative conversion multiple reaction monitor ((+/-)MRM) technique. With investigating three different columns, samples were separated in only 8 min on a Waters ACQUITY UPLC HSS T3 (50 × 2.1 mm(2), 1.8 μm) column using acetonitrile and formic acid-water solution as a mobile phase with a flow rate at 0.2 mL/min. All calibration curves showed good linearity (r>0.999) within the test ranges. The method developed was validated with acceptable sensitivity, intra- and inter-day precision, reproducibility, and extraction recoveries. It was successfully applied to the determination of eight alkaloids in Portulaca oleracea L. from different sources and different harvest periods. The method also provide a reference for extraction and determination of alkaloids in other complex systems. © 2013 Elsevier B.V. All rights reserved.

  4. Quantification of methionine and selenomethionine in biological samples using multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS).

    Science.gov (United States)

    Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel

    2018-05-01

    Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.

  5. System and process for pulsed multiple reaction monitoring

    Science.gov (United States)

    Belov, Mikhail E

    2013-05-17

    A new pulsed multiple reaction monitoring process and system are disclosed that uses a pulsed ion injection mode for use in conjunction with triple-quadrupole instruments. The pulsed injection mode approach reduces background ion noise at the detector, increases amplitude of the ion signal, and includes a unity duty cycle that provides a significant sensitivity increase for reliable quantitation of proteins/peptides present at attomole levels in highly complex biological mixtures.

  6. Verification of multimarkers for detection of early stage diabetic retinopathy using multiple reaction monitoring.

    Science.gov (United States)

    Kim, Kyunggon; Kim, Sang Jin; Han, Dohyun; Jin, Jonghwa; Yu, Jiyoung; Park, Kyong Soo; Yu, Hyeong Gon; Kim, Youngsoo

    2013-03-01

    Diabetic retinopathy (DR) is a complication of diabetes and 80% of diabetes mellitus (DM) patients whose DM duration is over 10 years can be expected to suffer with DR. The diagnosis of DR depends on an ophthalmological examination, and no molecular methods of screening DR status exist. Nonproliferative diabetic retinopathy (NPDR) is the early DR which is hard to be noticed in early NPDR, showing significant cause of adult blindness in type 2 diabetes patients. Protein biomarkers have been valuable in the diagnosis of disease and the use of multiple biomarkers has been suggested to overcome the low specificity of single ones. For biomarker development, multiple reaction monitoring (MRM) has been spotlighted as an alternative method to quantify target proteins with no need for immunoassay. In this study, 54 candidate DR marker proteins from a previous study were verified by MRM in plasma samples from NPDR patients in 3 stages (mild, moderate and severe; 15 cases each) and diabetic patients without retinopathy (15 cases) as a control. Notably, 27 candidate markers distinguished moderate NPDR from type 2 diabetic patients with no diabetic retinopathy, generating AUC values (>0.7). Specifically, 28 candidate proteins underwent changes in expression as type 2 diabetic patients with no diabetic retinopathy progressed to mild and moderate NPDR. Further, a combination of 4 markers from these 28 candidates had the improved specificity in distinguishing moderate NPDR from type 2 diabetic patients with no diabetic retinopathy, yielding a merged AUC value of nearly 1.0. We concluded that MRM is a fast, robust approach of multimarker panel determination and an assay platform that provides improved specificity compared with single biomarker assay systems.

  7. MRMer, an interactive open source and cross-platform system for data extraction and visualization of multiple reaction monitoring experiments.

    Science.gov (United States)

    Martin, Daniel B; Holzman, Ted; May, Damon; Peterson, Amelia; Eastham, Ashley; Eng, Jimmy; McIntosh, Martin

    2008-11-01

    Multiple reaction monitoring (MRM) mass spectrometry identifies and quantifies specific peptides in a complex mixture with very high sensitivity and speed and thus has promise for the high throughput screening of clinical samples for candidate biomarkers. We have developed an interactive software platform, called MRMer, for managing highly complex MRM-MS experiments, including quantitative analyses using heavy/light isotopic peptide pairs. MRMer parses and extracts information from MS files encoded in the platform-independent mzXML data format. It extracts and infers precursor-product ion transition pairings, computes integrated ion intensities, and permits rapid visual curation for analyses exceeding 1000 precursor-product pairs. Results can be easily output for quantitative comparison of consecutive runs. Additionally MRMer incorporates features that permit the quantitative analysis experiments including heavy and light isotopic peptide pairs. MRMer is open source and provided under the Apache 2.0 license.

  8. Branched alkanes from ancient and modern sediments: isomer discrimination by GC/MS with multiple reaction monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Summons, R.E.

    1987-01-01

    Linked scanning of a tandem sector mass spectrometer has been used to identify abundant, first field free region (FFR1) unimolecular fragmentations in branched and isoprenoid hydrocarbons. The most intense, structure-specific reactions were selected to establish multiple reaction monitoring (MRM) parameters for GC/MS analysis. This methodology has been used to study the identify of co-eluting and closely eluting hydrocarbon biomarkers from modern and ancient sediments and from extant microorganisms. Some sediments of Cambrian and Proterozoic age have been found to contain suites of monomethylalkanes with all possible isomers present and with little apparent preference for the site of branching.

  9. The application of multiple reaction monitoring to assess ApoA-I methionine oxidations in diabetes and cardiovascular disease

    Directory of Open Access Journals (Sweden)

    Hussein N. Yassine

    2014-12-01

    Full Text Available The oxidative modification of apolipoprotein A-I’s methionine148 (M148 is associated with defective HDL function in vitro. Multiple reaction monitoring (MRM is a mass spectrometric technique that can be used to quantitate post-translational modifications. In this study, we developed an MRM assay to monitor the abundance ratio of the peptide containing oxidized M148 to the native peptide in ApoA-I. Measurement of the oxidized-to-unoxidized-M148 ratio was reproducible (CV < 5%. The extent of methionine M148 oxidation in the HDL of healthy controls, and type 2 diabetic participants with and without prior cardiovascular events (CVD were then examined. The results suggest a significant increase in the relative ratio of the peptide containing oxidized M148 to the unmodified peptide in the HDL of participants with diabetes and CVD (p < 0.001, compared to participants without CVD. Monitoring the abundance ratio of the peptides containing oxidized and unoxidized M148 by MRM provides a means of examining the relationship between M148 oxidation and vascular complications in CVD.

  10. COPD Exacerbation Biomarkers Validated Using Multiple Reaction Monitoring Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Janice M Leung

    Full Text Available Acute exacerbations of chronic obstructive pulmonary disease (AECOPD result in considerable morbidity and mortality. However, there are no objective biomarkers to diagnose AECOPD.We used multiple reaction monitoring mass spectrometry to quantify 129 distinct proteins in plasma samples from patients with COPD. This analytical approach was first performed in a biomarker cohort of patients hospitalized with AECOPD (Cohort A, n = 72. Proteins differentially expressed between AECOPD and convalescent states were chosen using a false discovery rate 1.2. Protein selection and classifier building were performed using an elastic net logistic regression model. The performance of the biomarker panel was then tested in two independent AECOPD cohorts (Cohort B, n = 37, and Cohort C, n = 109 using leave-pair-out cross-validation methods.Five proteins were identified distinguishing AECOPD and convalescent states in Cohort A. Biomarker scores derived from this model were significantly higher during AECOPD than in the convalescent state in the discovery cohort (p<0.001. The receiver operating characteristic cross-validation area under the curve (CV-AUC statistic was 0.73 in Cohort A, while in the replication cohorts the CV-AUC was 0.77 for Cohort B and 0.79 for Cohort C.A panel of five biomarkers shows promise in distinguishing AECOPD from convalescence and may provide the basis for a clinical blood test to diagnose AECOPD. Further validation in larger cohorts is necessary for future clinical translation.

  11. A sensitive mass spectrometric method for hypothesis-driven detection of peptide post-translational modifications: multiple reaction monitoring-initiated detection and sequencing (MIDAS).

    Science.gov (United States)

    Unwin, Richard D; Griffiths, John R; Whetton, Anthony D

    2009-01-01

    The application of a targeted mass spectrometric workflow to the sensitive identification of post-translational modifications is described. This protocol employs multiple reaction monitoring (MRM) to search for all putative peptides specifically modified in a target protein. Positive MRMs trigger an MS/MS experiment to confirm the nature and site of the modification. This approach, termed MIDAS (MRM-initiated detection and sequencing), is more sensitive than approaches using neutral loss scanning or precursor ion scanning methodologies, due to a more efficient use of duty cycle along with a decreased background signal associated with MRM. We describe the use of MIDAS for the identification of phosphorylation, with a typical experiment taking just a couple of hours from obtaining a peptide sample. With minor modifications, the MIDAS method can be applied to other protein modifications or unmodified peptides can be used as a MIDAS target.

  12. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

    Science.gov (United States)

    Choi, Yong Seok; Lee, Kelvin H

    2016-03-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.

  13. Multiple reaction monitoring targeted LC-MS analysis of potential cell death marker proteins for increased bioprocess control.

    Science.gov (United States)

    Albrecht, Simone; Kaisermayer, Christian; Reinhart, David; Ambrose, Monica; Kunert, Renate; Lindeberg, Anna; Bones, Jonathan

    2018-05-01

    The monitoring of protein biomarkers for the early prediction of cell stress and death is a valuable tool for process characterization and efficient biomanufacturing control. A representative set of six proteins, namely GPDH, PRDX1, LGALS1, CFL1, TAGLN2 and MDH, which were identified in a previous CHO-K1 cell death model using discovery LC-MS E was translated into a targeted liquid chromatography multiple reaction monitoring mass spectrometry (LC-MRM-MS) platform and verified. The universality of the markers was confirmed in a cell growth model for which three Chinese hamster ovary host cell lines (CHO-K1, CHO-S, CHO-DG44) were grown in batch culture in two different types of basal media. LC-MRM-MS was also applied to spent media (n = 39) from four perfusion biomanufacturing series. Stable isotope-labelled peptide analogues and a stable isotope-labelled monoclonal antibody were used for improved protein quantitation and simultaneous monitoring of the workflow reproducibility. Significant increases in protein concentrations were observed for all viability marker proteins upon increased dead cell numbers and allowed for discrimination of spent media with dead cell densities below and above 1 × 10 6  dead cells/mL which highlights the potential of the selected viability marker proteins in bioprocess control. Graphical abstract Overview of the LC-MRM-MS workflow for the determination of proteomic markers in conditioned media from the bioreactor that correlate with CHO cell death.

  14. Automatic identification approach for high-performance liquid chromatography-multiple reaction monitoring fatty acid global profiling.

    Science.gov (United States)

    Tie, Cai; Hu, Ting; Jia, Zhi-Xin; Zhang, Jin-Lan

    2015-08-18

    Fatty acids (FAs) are a group of lipid molecules that are essential to organisms. As potential biomarkers for different diseases, FAs have attracted increasing attention from both biological researchers and the pharmaceutical industry. A sensitive and accurate method for globally profiling and identifying FAs is required for biomarker discovery. The high selectivity and sensitivity of high-performance liquid chromatography-multiple reaction monitoring (HPLC-MRM) gives it great potential to fulfill the need to identify FAs from complicated matrices. This paper developed a new approach for global FA profiling and identification for HPLC-MRM FA data mining. Mathematical models for identifying FAs were simulated using the isotope-induced retention time (RT) shift (IRS) and peak area ratios between parallel isotope peaks for a series of FA standards. The FA structures were predicated using another model based on the RT and molecular weight. Fully automated FA identification software was coded using the Qt platform based on these mathematical models. Different samples were used to verify the software. A high identification efficiency (greater than 75%) was observed when 96 FA species were identified in plasma. This FAs identification strategy promises to accelerate FA research and applications.

  15. Acyl chains of phospholipase D transphosphatidylation products in Arabidopsis cells: a study using multiple reaction monitoring mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Dominique Rainteau

    Full Text Available BACKGROUND: Phospholipases D (PLD are major components of signalling pathways in plant responses to some stresses and hormones. The product of PLD activity is phosphatidic acid (PA. PAs with different acyl chains do not have the same protein targets, so to understand the signalling role of PLD it is essential to analyze the composition of its PA products in the presence and absence of an elicitor. METHODOLOGY/PRINCIPAL FINDINGS: Potential PLD substrates and products were studied in Arabidopsis thaliana suspension cells treated with or without the hormone salicylic acid (SA. As PA can be produced by enzymes other than PLD, we analyzed phosphatidylbutanol (PBut, which is specifically produced by PLD in the presence of n-butanol. The acyl chain compositions of PBut and the major glycerophospholipids were determined by multiple reaction monitoring (MRM mass spectrometry. PBut profiles of untreated cells or cells treated with SA show an over-representation of 160/18:2- and 16:0/18:3-species compared to those of phosphatidylcholine and phosphatidylethanolamine either from bulk lipid extracts or from purified membrane fractions. When microsomal PLDs were used in in vitro assays, the resulting PBut profile matched exactly that of the substrate provided. Therefore there is a mismatch between the acyl chain compositions of putative substrates and the in vivo products of PLDs that is unlikely to reflect any selectivity of PLDs for the acyl chains of substrates. CONCLUSIONS: MRM mass spectrometry is a reliable technique to analyze PLD products. Our results suggest that PLD action in response to SA is not due to the production of a stress-specific molecular species, but that the level of PLD products per se is important. The over-representation of 160/18:2- and 16:0/18:3-species in PLD products when compared to putative substrates might be related to a regulatory role of the heterogeneous distribution of glycerophospholipids in membrane sub-domains.

  16. Targeted Quantitation of Site-Specific Cysteine Oxidation in Endogenous Proteins Using a Differential Alkylation and Multiple Reaction Monitoring Mass Spectrometry Approach

    Science.gov (United States)

    Held, Jason M.; Danielson, Steven R.; Behring, Jessica B.; Atsriku, Christian; Britton, David J.; Puckett, Rachel L.; Schilling, Birgit; Campisi, Judith; Benz, Christopher C.; Gibson, Bradford W.

    2010-01-01

    Reactive oxygen species (ROS) are both physiological intermediates in cellular signaling and mediators of oxidative stress. The cysteine-specific redox-sensitivity of proteins can shed light on how ROS are regulated and function, but low sensitivity has limited quantification of the redox state of many fundamental cellular regulators in a cellular context. Here we describe a highly sensitive and reproducible oxidation analysis approach (OxMRM) that combines protein purification, differential alkylation with stable isotopes, and multiple reaction monitoring mass spectrometry that can be applied in a targeted manner to virtually any cysteine or protein. Using this approach, we quantified the site-specific cysteine oxidation status of endogenous p53 for the first time and found that Cys182 at the dimerization interface of the DNA binding domain is particularly susceptible to diamide oxidation intracellularly. OxMRM enables analysis of sulfinic and sulfonic acid oxidation levels, which we validate by assessing the oxidation of the catalytic Cys215 of protein tyrosine phosphatase-1B under numerous oxidant conditions. OxMRM also complements unbiased redox proteomics discovery studies as a verification tool through its high sensitivity, accuracy, precision, and throughput. PMID:20233844

  17. An alpha-synuclein MRM assay with diagnostic potential for Parkinson's disease and monitoring disease progression

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Li [Department of Pathology, University of Washington, Seattle WA USA; Stewart, Tessandra [Department of Pathology, University of Washington, Seattle WA USA; Shi, Min [Department of Pathology, University of Washington, Seattle WA USA; Pottiez, Gwenael [Department of Pathology, University of Washington, Seattle WA USA; Dator, Romel [Department of Pathology, University of Washington, Seattle WA USA; Wu, Rui [Department of Pathology, University of Washington, Seattle WA USA; Department of Pathology, No. 3 Hospital of Beijing University, Beijing China; Aro, Patrick [Department of Pathology, University of Washington, Seattle WA USA; Schuster, Robert J. [Department of Pathology, University of Washington, Seattle WA USA; Ginghina, Carmen [Department of Pathology, University of Washington, Seattle WA USA; Pan, Catherine [Department of Pathology, University of Washington, Seattle WA USA; Gao, Yuqian [Pacific Northwest National Laboratory, Richland WA USA; Qian, Weijun [Pacific Northwest National Laboratory, Richland WA USA; Zabetian, Cyrus P. [Parkinson' s Disease Research and Geriatric Research, Education and Clinical Center, Veterans Affairs Puget Sound Health Care System, Seattle WA USA; Department of Neurology, University of Washington School of Medicine, Seattle WA USA; Hu, Shu-Ching [Department of Neurology, University of Washington School of Medicine, Seattle WA USA; Quinn, Joseph F. [Department of Neurology, Oregon Health and Science University, Portland OR USA; Zhang, Jing [Department of Pathology, University of Washington, Seattle WA USA; Department of Pathology, Peking University Health Science Centre and Third Hospital, Beijing 100083 China

    2017-04-19

    Aim: The alpha-synuclein (α-syn) level in human cerebrospinal fluid (CSF), as measured by immunoassays, is promising as a Parkinson’s disease (PD) biomarker. However, the levels of total α-syn are inconsistent among studies with large cohorts and different measurement platforms. Total α-syn level also does not correlate with disease severity or progression. Here, we developed a highly sensitive Multiple Reaction Monitoring (MRM) method to measure absolute CSF α-syn peptide concentrations without prior enrichment or fractionation, aiming to discover new candidate biomarkers. Results: Six peptides covering 73% of protein sequence were reliably identified, and two were consistently quantified in cross-sectional and longitudinal cohorts. Absolute concentration of α-syn in human CSF was determined to be 2.1ng/mL. A unique α-syn peptide, TVEGAGSIAAATGFVK (81-96), displayed excellent correlation with previous immunoassay results in two independent PD cohorts (p < 0.001), correlated with disease severity, and its changes significantly tracked the disease progression longitudinally. Conclusions: An MRM assay to quantify human CSF α-syn was developed and optimized. Sixty clinical samples from cross-sectional and longitudinal PD cohorts were analyzed with this approach. Although further larger-scale validation is needed, the results suggest that α-syn peptide could serve as a promising biomarker in PD diagnosis and progression.

  18. Stepped MS(All) Relied Transition (SMART): An approach to rapidly determine optimal multiple reaction monitoring mass spectrometry parameters for small molecules.

    Science.gov (United States)

    Ye, Hui; Zhu, Lin; Wang, Lin; Liu, Huiying; Zhang, Jun; Wu, Mengqiu; Wang, Guangji; Hao, Haiping

    2016-02-11

    Multiple reaction monitoring (MRM) is a universal approach for quantitative analysis because of its high specificity and sensitivity. Nevertheless, optimization of MRM parameters remains as a time and labor-intensive task particularly in multiplexed quantitative analysis of small molecules in complex mixtures. In this study, we have developed an approach named Stepped MS(All) Relied Transition (SMART) to predict the optimal MRM parameters of small molecules. SMART requires firstly a rapid and high-throughput analysis of samples using a Stepped MS(All) technique (sMS(All)) on a Q-TOF, which consists of serial MS(All) events acquired from low CE to gradually stepped-up CE values in a cycle. The optimal CE values can then be determined by comparing the extracted ion chromatograms for the ion pairs of interest among serial scans. The SMART-predicted parameters were found to agree well with the parameters optimized on a triple quadrupole from the same vendor using a mixture of standards. The parameters optimized on a triple quadrupole from a different vendor was also employed for comparison, and found to be linearly correlated with the SMART-predicted parameters, suggesting the potential applications of the SMART approach among different instrumental platforms. This approach was further validated by applying to simultaneous quantification of 31 herbal components in the plasma of rats treated with a herbal prescription. Because the sMS(All) acquisition can be accomplished in a single run for multiple components independent of standards, the SMART approach are expected to find its wide application in the multiplexed quantitative analysis of complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Development and validation of LC-MS/MS method with multiple reactions monitoring mode for quantification of vanillin and syringaldehyde in plum brandies

    Directory of Open Access Journals (Sweden)

    Tešević Vele

    2014-01-01

    Full Text Available An ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS method with multiple reactions monitoring mode (MRM has been developed and validated for quantification of vanillin and syringaldehyde in plum brandy. The method showed good linearity (0.05 to 10 mgL−1 and low limits of detection and quantification (LOD and LOQ were 11.6 µgL−1 and 38.2 µgL−1 for vanillin, and 12.7 µgL−1 and 42.0 µgL−1 for syringaldehyde, respectively. The overall intra-day and inter-day variations were less than 4.21%, and the overall recovery over 93.0%. The correlation coefficients (R2 of the calibration curves were higher than 0.9999. In order to evaluate if the method is suitable for use as a routine analytical tool, in 31 Serbian plum brandy samples vanillin and syringaldehide were determined. [Projekat Ministarstva nauke Republike Srbije, br. 172053

  20. Rapid determination of alkaloids in Macleaya cordata using ionic liquid extraction followed by multiple reaction monitoring UPLC-MS/MS analysis.

    Science.gov (United States)

    Li, Linqiu; Huang, Mingyuan; Shao, Junli; Lin, Bokun; Shen, Qing

    2017-02-20

    The ultrasonic-assisted extraction (UAE) and ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) have been successfully applied in extracting of six alkaloids from M. cordata. 1-hexyl-3-methylimidazolium tetrafluoroborate ([C 6 MIM][BF 4 ]) aqueous solution was used as extraction solvent. The target analytes in raw material were deposited into a single drop of 1-hexyl-3-methylimidazolium hexafluorophosphate ([C 6 MIM][PF 6 ]), which was in situ formed by mixing [C 6 MIM][BF 4 ] and potassium hexafluorophosphate ([K][PF 6 ]. Afterwards, the extract was analyzed by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in multiple-reaction monitoring (MRM) mode. The proposed method was fully validated in terms of linearity (0.9983-0.9992), LOD (0.080ngmL -1 ), LOQ (0.25ngmL -1 ), intra-day precision (MS/MS is powerful and practical for analyzing alkaloids in M. cordata., and it also has great potential for comprehensive quality control of other herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest.

    Science.gov (United States)

    Sun, Liangliang; Li, Yihan; Champion, Matthew M; Zhu, Guijie; Wojcik, Roza; Dovichi, Norman J

    2013-06-07

    Capillary zone electrophoresis-multiple/single reaction monitoring (CZE-MRM/SRM), which employed an electrokinetically driven sheath-flow electrospray interface, was used for the rapid and highly sensitive detection of protein analytes in complex tryptic digests. MRM channels were developed against a commercial exponential mixture of bovine proteins. Five proteins spanning four orders of magnitude concentration range were confidently detected from only 2.5 ng of the digest mixture; the mass detection limits (S/N = 3) of two detected proteins, alpha-casein and glutamate dehydrogenase were about 600 zmol and 30 amol, respectively. This technique was then applied to a RAW 264.7 cell lysate digest. Three proteins were confidently and reproducibly detected from 100 pg of this digest. The sample amount corresponds to the approximate protein content from a single cell, which suggests that CZE-MRM may be a useful analytical tool in chemical cytometry. In addition to providing highly sensitive detection of proteins in complex mixtures, this system is highly rapid; migration time of the protein digests was less than 10 min.

  2. Quantitative changes in proteins responsible for flavonoid and anthocyanin biosynthesis in strawberry fruit at different ripening stages: A targeted quantitative proteomic investigation employing multiple reaction monitoring.

    Science.gov (United States)

    Song, Jun; Du, Lina; Li, Li; Kalt, Wilhelmina; Palmer, Leslie Campbell; Fillmore, Sherry; Zhang, Ying; Zhang, ZhaoQi; Li, XiHong

    2015-06-03

    To better understand the regulation of flavonoid and anthocyanin biosynthesis, a targeted quantitative proteomic investigation employing LC-MS with multiple reaction monitoring was conducted on two strawberry cultivars at three ripening stages. This quantitative proteomic workflow was improved through an OFFGEL electrophoresis to fractionate peptides from total protein digests. A total of 154 peptide transitions from 47 peptides covering 21 proteins and isoforms related to anthocyanin biosynthesis were investigated. The normalized protein abundance, which was measured using isotopically-labeled standards, was significantly changed concurrently with increased anthocyanin content and advanced fruit maturity. The protein abundance of phenylalanine ammonia-lyase; anthocyanidin synthase, chalcone isomerase; flavanone 3-hydroxylase; dihydroflavonol 4-reductase, UDP-glucose:flavonoid-3-O-glucosyltransferase, cytochrome c and cytochrome C oxidase subunit 2, was all significantly increased in fruit of more advanced ripeness. An interaction between cultivar and maturity was also shown with respect to chalcone isomerase. The good correlation between protein abundance and anthocyanin content suggested that a metabolic control point may exist for anthocyanin biosynthesis. This research provides insights into the process of anthocyanin formation in strawberry fruit at the level of protein concentration and reveals possible candidates in the regulation of anthocyanin formation during fruit ripening. To gain insight into the molecular mechanisms contributing to flavonoids and anthocyanin biosynthesis and regulation of strawberry fruit during ripening is challenging due to limited molecular biology tools and established hypothesis. Our targeted proteomic approach employing LC-MS/MS analysis and MRM technique to quantify proteins in relation to flavonoids and anthocyanin biosynthesis and regulation in strawberry fruit during fruit ripening is novel. The identification of peptides

  3. Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasma

    Science.gov (United States)

    Addona, Terri A; Abbatiello, Susan E; Schilling, Birgit; Skates, Steven J; Mani, D R; Bunk, David M; Spiegelman, Clifford H; Zimmerman, Lisa J; Ham, Amy-Joan L; Keshishian, Hasmik; Hall, Steven C; Allen, Simon; Blackman, Ronald K; Borchers, Christoph H; Buck, Charles; Cardasis, Helene L; Cusack, Michael P; Dodder, Nathan G; Gibson, Bradford W; Held, Jason M; Hiltke, Tara; Jackson, Angela; Johansen, Eric B; Kinsinger, Christopher R; Li, Jing; Mesri, Mehdi; Neubert, Thomas A; Niles, Richard K; Pulsipher, Trenton C; Ransohoff, David; Rodriguez, Henry; Rudnick, Paul A; Smith, Derek; Tabb, David L; Tegeler, Tony J; Variyath, Asokan M; Vega-Montoto, Lorenzo J; Wahlander, Åsa; Waldemarson, Sofia; Wang, Mu; Whiteaker, Jeffrey R; Zhao, Lei; Anderson, N Leigh; Fisher, Susan J; Liebler, Daniel C; Paulovich, Amanda G; Regnier, Fred E; Tempst, Paul; Carr, Steven A

    2010-01-01

    Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low µg/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma. PMID:19561596

  4. SWATHtoMRM: Development of High-Coverage Targeted Metabolomics Method Using SWATH Technology for Biomarker Discovery.

    Science.gov (United States)

    Zha, Haihong; Cai, Yuping; Yin, Yandong; Wang, Zhuozhong; Li, Kang; Zhu, Zheng-Jiang

    2018-03-20

    The complexity of metabolome presents a great analytical challenge for quantitative metabolite profiling, and restricts the application of metabolomics in biomarker discovery. Targeted metabolomics using multiple-reaction monitoring (MRM) technique has excellent capability for quantitative analysis, but suffers from the limited metabolite coverage. To address this challenge, we developed a new strategy, namely, SWATHtoMRM, which utilizes the broad coverage of SWATH-MS technology to develop high-coverage targeted metabolomics method. Specifically, SWATH-MS technique was first utilized to untargeted profile one pooled biological sample and to acquire the MS 2 spectra for all metabolites. Then, SWATHtoMRM was used to extract the large-scale MRM transitions for targeted analysis with coverage as high as 1000-2000 metabolites. Then, we demonstrated the advantages of SWATHtoMRM method in quantitative analysis such as coverage, reproducibility, sensitivity, and dynamic range. Finally, we applied our SWATHtoMRM approach to discover potential metabolite biomarkers for colorectal cancer (CRC) diagnosis. A high-coverage targeted metabolomics method with 1303 metabolites in one injection was developed to profile colorectal cancer tissues from CRC patients. A total of 20 potential metabolite biomarkers were discovered and validated for CRC diagnosis. In plasma samples from CRC patients, 17 out of 20 potential biomarkers were further validated to be associated with tumor resection, which may have a great potential in assessing the prognosis of CRC patients after tumor resection. Together, the SWATHtoMRM strategy provides a new way to develop high-coverage targeted metabolomics method, and facilitates the application of targeted metabolomics in disease biomarker discovery. The SWATHtoMRM program is freely available on the Internet ( http://www.zhulab.cn/software.php ).

  5. Liquid chromatography-electrospray ionization tandem mass spectrometry and dynamic multiple reaction monitoring method for determining multiple pesticide residues in tomato.

    Science.gov (United States)

    Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L

    2015-05-15

    A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Intact protein analysis of ubiquitin in cerebrospinal fluid by multiple reaction monitoring reveals differences in Alzheimer's disease and frontotemporal lobar degeneration.

    Science.gov (United States)

    Oeckl, Patrick; Steinacker, Petra; von Arnim, Christine A F; Straub, Sarah; Nagl, Magdalena; Feneberg, Emily; Weishaupt, Jochen H; Ludolph, Albert C; Otto, Markus

    2014-11-07

    The impairment of the ubiquitin-proteasome system (UPS) is thought to be an early event in neurodegeneration, and monitoring UPS alterations might serve as a disease biomarker. Our aim was to establish an alternate method to antibody-based assays for the selective measurement of free monoubiquitin in cerebrospinal fluid (CSF). Free monoubiquitin was measured with liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MS/MS) in CSF of patients with Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), behavioral variant of frontotemporal dementia (bvFTD), Creutzfeldt-Jakob disease (CJD), Parkinson's disease (PD), primary progressive aphasia (PPA), and progressive supranuclear palsy (PSP). The LC-MS/MS method showed excellent intra- and interassay precision (4.4-7.4% and 4.9-10.3%) and accuracy (100-107% and 100-106%). CSF ubiquitin concentration was increased compared with that of controls (33.0 ± 9.7 ng/mL) in AD (47.5 ± 13.1 ng/mL, p < 0.05) and CJD patients (171.5 ± 103.5 ng/mL, p < 0.001) but not in other neurodegenerative diseases. Receiver operating characteristic curve (ROC) analysis of AD vs control patients revealed an area under the curve (AUC) of 0.832, and the specificity and sensitivity were 75 and 75%, respectively. ROC analysis of AD and FTLD patients yielded an AUC of 0.776, and the specificity and sensitivity were 53 and 100%, respectively. In conclusion, our LC-MS/MS method may facilitate ubiquitin determination to a broader community and might help to discriminate AD, CJD, and FTLD patients.

  7. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  8. Review of software tools for design and analysis of large scale MRM proteomic datasets.

    Science.gov (United States)

    Colangelo, Christopher M; Chung, Lisa; Bruce, Can; Cheung, Kei-Hoi

    2013-06-15

    Selective or Multiple Reaction monitoring (SRM/MRM) is a liquid-chromatography (LC)/tandem-mass spectrometry (MS/MS) method that enables the quantitation of specific proteins in a sample by analyzing precursor ions and the fragment ions of their selected tryptic peptides. Instrumentation software has advanced to the point that thousands of transitions (pairs of primary and secondary m/z values) can be measured in a triple quadrupole instrument coupled to an LC, by a well-designed scheduling and selection of m/z windows. The design of a good MRM assay relies on the availability of peptide spectra from previous discovery-phase LC-MS/MS studies. The tedious aspect of manually developing and processing MRM assays involving thousands of transitions has spurred to development of software tools to automate this process. Software packages have been developed for project management, assay development, assay validation, data export, peak integration, quality assessment, and biostatistical analysis. No single tool provides a complete end-to-end solution, thus this article reviews the current state and discusses future directions of these software tools in order to enable researchers to combine these tools for a comprehensive targeted proteomics workflow. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  9. MR mammography (MRM)

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, W.A.

    1993-01-01

    The book deals with MRI for the diagnostic evaluation of malignant breast lesions. A survey of methods available for breast examination, magnetic resonance mammography (MRM) is briefly explained in terms of development and technical problems encountered in the various examinations. The clinical aspects from a central part of the book, giving information relating to the various neoplasms and a comprehensive review of cases. The book concludes with a chapter discussing the interpretation of data and images, presenting examples of normal findings and of manifestations of carcinoma, fibroadenoma, cysts, mastopathies, scars due to plastic surgery, and the lactating breast. (UWA). 648 figs., 25 tabs.

  10. Comparison of pharmacokinetic behavior of two iridoid glycosides in rat plasma after oral administration of crude Cornus officinals and its jiuzhipin by high performance liquid chromatography triple quadrupole mass spectrometry combined with multiple reactions monitoring mode

    Science.gov (United States)

    Chen, Xiaocheng; Cao, Gang; Jiang, Jianping

    2014-01-01

    Objective: The present study examined the pharmacokinetic profiles of two iridoid glycosides named morroniside and loganin in rat plasma after oral administration of crude and processed Cornus officinals. Materials and Methods: A rapid, selective and specific high-performance liquid chromatography/electrospray ionization tandem mass spectrometry with multiple reactions monitoring mode was developed to simultaneously investigate the pharmacokinetic profiles of morroniside and loganin in rat plasma after oral administration of crude C. officinals and its jiuzhipin. Results: The morroniside and loganin in crude and processed C. officinals could be simultaneously determined within 7.4 min. Linear calibration curves were obtained over the concentration ranges of 45.45-4800 ng/mL for all the analytes. The intra-and inter-day precisions relative standard deviation was lesser than 2.84% and 4.12%, respectively. Conclusion: The pharmacokinetic parameters of two iridoid glucosides were also compared systematically between crude and processed C. officinals. This paper provides the theoretical proofs for further explaining the processing mechanism of Traditional Chinese Medicines. PMID:24914290

  11. An MRM-based workflow for absolute quantitation of lysine-acetylated metabolic enzymes in mouse liver.

    Science.gov (United States)

    Xu, Leilei; Wang, Fang; Xu, Ying; Wang, Yi; Zhang, Cuiping; Qin, Xue; Yu, Hongxiu; Yang, Pengyuan

    2015-12-07

    As a key post-translational modification mechanism, protein acetylation plays critical roles in regulating and/or coordinating cell metabolism. Acetylation is a prevalent modification process in enzymes. Protein acetylation modification occurs in sub-stoichiometric amounts; therefore extracting biologically meaningful information from these acetylation sites requires an adaptable, sensitive, specific, and robust method for their quantification. In this work, we combine immunoassays and multiple reaction monitoring-mass spectrometry (MRM-MS) technology to develop an absolute quantification for acetylation modification. With this hybrid method, we quantified the acetylation level of metabolic enzymes, which could demonstrate the regulatory mechanisms of the studied enzymes. The development of this quantitative workflow is a pivotal step for advancing our knowledge and understanding of the regulatory effects of protein acetylation in physiology and pathophysiology.

  12. Quantitative analysis of core fucosylation of serum proteins in liver diseases by LC-MS-MRM.

    Science.gov (United States)

    Ma, Junfeng; Sanda, Miloslav; Wei, Renhuizi; Zhang, Lihua; Goldman, Radoslav

    2018-02-07

    Aberrant core fucosylation of proteins has been linked to liver diseases. In this study, we carried out multiple reaction monitoring (MRM) quantification of core fucosylated N-glycopeptides of serum proteins partially deglycosylated by a combination of endoglycosidases (endoF1, endoF2, and endoF3). To minimize variability associated with the preparatory steps, the analysis was performed without enrichment of glycopeptides or fractionation of serum besides the nanoRP chromatography. Specifically, we quantified core fucosylation of 22 N-glycopeptides derived from 17 proteins together with protein abundance of these glycoproteins in a cohort of 45 participants (15 disease-free control, 15 fibrosis and 15 cirrhosis patients) using a multiplex nanoUPLC-MS-MRM workflow. We find increased core fucosylation of 5 glycopeptides at the stage of liver fibrosis (i.e., N630 of serotransferrin, N107 of alpha-1-antitrypsin, N253 of plasma protease C1 inhibitor, N397 of ceruloplasmin, and N86 of vitronectin), increase of additional 6 glycopeptides at the stage of cirrhosis (i.e., N138 and N762 of ceruloplasmin, N354 of clusterin, N187 of hemopexin, N71 of immunoglobulin J chain, and N127 of lumican), while the degree of core fucosylation of 10 glycopeptides did not change. Interestingly, although we observe an increase in the core fucosylation at N86 of vitronectin in liver fibrosis, core fucosylation decreases on the N169 glycopeptide of the same protein. Our results demonstrate that the changes in core fucosylation are protein and site specific during the progression of fibrotic liver disease and independent of the changes in the quantity of N-glycoproteins. It is expected that the fully optimized multiplex LC-MS-MRM assay of core fucosylated glycopeptides will be useful for the serologic assessment of the fibrosis of liver. We have quantified the difference in core fucosylation among three comparison groups (healthy control, fibrosis and cirrhosis patients) using a sensitive and

  13. Simultaneous quantification of endogenous and exogenous plasma glucose by isotope dilution LC-MS/MS with indirect MRM of the derivative tag.

    Science.gov (United States)

    Yu, Lingling; Wen, Chao; Li, Xing; Fang, Shiqi; Yang, Lichuan; Wang, Tony; Hu, Kaifeng

    2018-03-01

    Quantification of endogenous and exogenous plasma glucose can help more comprehensively evaluate the glucose metabolic status. A ratio-based approach using isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) with indirect multiple reaction monitoring (MRM) of the derivative tag was developed to simultaneously quantify endo-/exogenous plasma glucose. Using diluted D-[ 13 C 6 ] glucose as tracer of exogenous glucose, 12 C 6 / 13 C 6 glucoses were first derivatized and then data were acquired in MRM mode. The metabolism of exogenous glucose can be tracked and the concentration ratio of endo/exo-genous glucose can be measured by calculating the endo-/exo-genous glucose concentrations from peak area ratio of specific daughter ions. Joint application of selective derivatization and MRM analysis not only improves the sensitivity but also minimizes the interference from the background of plasma, which warrants the accuracy and reproducibility. Good agreement between the theoretical and calculated concentration ratios was obtained with a linear correlation coefficient (R) of 0.9969 in the range of D-glucose from 0.5 to 20.0 mM, which covers the healthy and diabetic physiological scenarios. Satisfactory reproducibility was obtained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 5.16%, and relative recoveries of 85.96 to 95.92% were obtained at low, medium, and high concentration, respectively. The method was successfully applied to simultaneous determination of the endo-/exogenous glucose concentration in plasma of non-diabetic and type II diabetic cynomolgus monkeys. Graphical Abstract The scheme of the proposed ratio-based approach using isotope dilution LC-MS/MS with indirect MRM of the derivative tag for simultaneous quantification of endogenous and exogenous plasma glucose.

  14. UPLC-MRM Mass Spectrometry Method for Measurement of the Coagulation Inhibitors Dabigatran and Rivaroxaban in Human Plasma and Its Comparison with Functional Assays.

    Science.gov (United States)

    Kuhn, Joachim; Gripp, Tatjana; Flieder, Tobias; Dittrich, Marcus; Hendig, Doris; Busse, Jessica; Knabbe, Cornelius; Birschmann, Ingvild

    2015-01-01

    The fast, precise, and accurate measurement of the new generation of oral anticoagulants such as dabigatran and rivaroxaban in patients' plasma my provide important information in different clinical circumstances such as in the case of suspicion of overdose, when patients switch from existing oral anticoagulant, in patients with hepatic or renal impairment, by concomitant use of interaction drugs, or to assess anticoagulant concentration in patients' blood before major surgery. Here, we describe a quick and precise method to measure the coagulation inhibitors dabigatran and rivaroxaban using ultra-performance liquid chromatography electrospray ionization-tandem mass spectrometry in multiple reactions monitoring (MRM) mode (UPLC-MRM MS). Internal standards (ISs) were added to the sample and after protein precipitation; the sample was separated on a reverse phase column. After ionization of the analytes the ions were detected using electrospray ionization-tandem mass spectrometry. Run time was 2.5 minutes per injection. Ion suppression was characterized by means of post-column infusion. The calibration curves of dabigatran and rivaroxaban were linear over the working range between 0.8 and 800 μg/L (r >0.99). Limits of detection (LOD) in the plasma matrix were 0.21 μg/L for dabigatran and 0.34 μg/L for rivaroxaban, and lower limits of quantification (LLOQ) in the plasma matrix were 0.46 μg/L for dabigatran and 0.54 μg/L for rivaroxaban. The intraassay coefficients of variation (CVs) for dabigatran and rivaroxaban were method comparison between our UPLC-MRM MS method, the commercially available automated Direct Thrombin Inhibitor assay (DTI assay) for dabigatran measurement from CoaChrom Diagnostica, as well as the automated anti-Xa assay for rivaroxaban measurement from Chromogenix both performed by ACL-TOP showed a high degree of correlation. However, UPLC-MRM MS measurement of dabigatran and rivaroxaban has a much better selectivity than classical functional

  15. MRM screening/biomarker discovery with linear ion trap MS: a library of human cancer-specific peptides

    International Nuclear Information System (INIS)

    Yang, Xu; Lazar, Iulia M

    2009-01-01

    The discovery of novel protein biomarkers is essential in the clinical setting to enable early disease diagnosis and increase survivability rates. To facilitate differential expression analysis and biomarker discovery, a variety of tandem mass spectrometry (MS/MS)-based protein profiling techniques have been developed. For achieving sensitive detection and accurate quantitation, targeted MS screening approaches, such as multiple reaction monitoring (MRM), have been implemented. MCF-7 breast cancer protein cellular extracts were analyzed by 2D-strong cation exchange (SCX)/reversed phase liquid chromatography (RPLC) separations interfaced to linear ion trap MS detection. MS data were interpreted with the Sequest-based Bioworks software (Thermo Electron). In-house developed Perl-scripts were used to calculate the spectral counts and the representative fragment ions for each peptide. In this work, we report on the generation of a library of 9,677 peptides (p < 0.001), representing ~1,572 proteins from human breast cancer cells, that can be used for MRM/MS-based biomarker screening studies. For each protein, the library provides the number and sequence of detectable peptides, the charge state, the spectral count, the molecular weight, the parameters that characterize the quality of the tandem mass spectrum (p-value, DeltaM, Xcorr, DeltaCn, Sp, no. of matching a, b, y ions in the spectrum), the retention time, and the top 10 most intense product ions that correspond to a given peptide. Only proteins identified by at least two spectral counts are listed. The experimental distribution of protein frequencies, as a function of molecular weight, closely matched the theoretical distribution of proteins in the human proteome, as provided in the SwissProt database. The amino acid sequence coverage of the identified proteins ranged from 0.04% to 98.3%. The highest-abundance proteins in the cellular extract had a molecular weight (MW)<50,000. Preliminary experiments have

  16. A Fast and Robust UHPLC-MRM-MS Method to Characterize and Quantify Grape Skin Tannins after Chemical Depolymerization.

    Science.gov (United States)

    Pinasseau, Lucie; Verbaere, Arnaud; Roques, Maryline; Meudec, Emmanuelle; Vallverdú-Queralt, Anna; Terrier, Nancy; Boulet, Jean-Claude; Cheynier, Véronique; Sommerer, Nicolas

    2016-10-21

    A rapid, sensitive, and selective analysis method using ultra high performance liquid chromatography coupled with triple-quadrupole mass spectrometry (UHPLC-QqQ-MS) has been developed for the characterization and quantification of grape skin flavan-3-ols after acid-catalysed depolymerization in the presence of phloroglucinol (phloroglucinolysis). The compound detection being based on specific MS transitions in Multiple Reaction Monitoring (MRM) mode, this fast gradient robust method allows analysis of constitutive units of grape skin proanthocyanidins, including some present in trace amounts, in a single injection, with a throughput of 6 samples per hour. This method was applied to a set of 214 grape skin samples from 107 different red and white grape cultivars grown under two conditions in the vineyard, irrigated or non-irrigated. The results of triplicate analyses confirmed the robustness of the method, which was thus proven to be suitable for high-throughput and large-scale metabolomics studies. Moreover, these preliminary results suggest that analysis of tannin composition is relevant to investigate the genetic bases of grape response to drought.

  17. Application of enhanced gas chromatography/triple quadrupole mass spectrometry for monitoring petroleum weathering and forensic source fingerprinting in samples impacted by the Deepwater Horizon oil spill.

    Science.gov (United States)

    Adhikari, Puspa L; Wong, Roberto L; Overton, Edward B

    2017-10-01

    Accurate characterization of petroleum hydrocarbons in complex and weathered oil residues is analytically challenging. This is primarily due to chemical compositional complexity of both the oil residues and environmental matrices, and the lack of instrumental selectivity due to co-elution of interferences with the target analytes. To overcome these analytical selectivity issues, we used an enhanced resolution gas chromatography coupled with triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode (GC/MS/MS-MRM) to eliminate interferences within the ion chromatograms of target analytes found in environmental samples. This new GC/MS/MS-MRM method was developed and used for forensic fingerprinting of deep-water and marsh sediment samples containing oily residues from the Deepwater Horizon oil spill. The results showed that the GC/MS/MS-MRM method increases selectivity, eliminates interferences, and provides more accurate quantitation and characterization of trace levels of alkyl-PAHs and biomarker compounds, from weathered oil residues in complex sample matrices. The higher selectivity of the new method, even at low detection limits, provides greater insights on isomer and homolog compositional patterns and the extent of oil weathering under various environmental conditions. The method also provides flat chromatographic baselines for accurate and unambiguous calculation of petroleum forensic biomarker compound ratios. Thus, this GC/MS/MS-MRM method can be a reliable analytical strategy for more accurate and selective trace level analyses in petroleum forensic studies, and for tacking continuous weathering of oil residues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. UPLC-MRM Mass Spectrometry Method for Measurement of the Coagulation Inhibitors Dabigatran and Rivaroxaban in Human Plasma and Its Comparison with Functional Assays.

    Directory of Open Access Journals (Sweden)

    Joachim Kuhn

    Full Text Available The fast, precise, and accurate measurement of the new generation of oral anticoagulants such as dabigatran and rivaroxaban in patients' plasma my provide important information in different clinical circumstances such as in the case of suspicion of overdose, when patients switch from existing oral anticoagulant, in patients with hepatic or renal impairment, by concomitant use of interaction drugs, or to assess anticoagulant concentration in patients' blood before major surgery.Here, we describe a quick and precise method to measure the coagulation inhibitors dabigatran and rivaroxaban using ultra-performance liquid chromatography electrospray ionization-tandem mass spectrometry in multiple reactions monitoring (MRM mode (UPLC-MRM MS. Internal standards (ISs were added to the sample and after protein precipitation; the sample was separated on a reverse phase column. After ionization of the analytes the ions were detected using electrospray ionization-tandem mass spectrometry. Run time was 2.5 minutes per injection. Ion suppression was characterized by means of post-column infusion.The calibration curves of dabigatran and rivaroxaban were linear over the working range between 0.8 and 800 μg/L (r >0.99. Limits of detection (LOD in the plasma matrix were 0.21 μg/L for dabigatran and 0.34 μg/L for rivaroxaban, and lower limits of quantification (LLOQ in the plasma matrix were 0.46 μg/L for dabigatran and 0.54 μg/L for rivaroxaban. The intraassay coefficients of variation (CVs for dabigatran and rivaroxaban were < 4% and 6%; respectively, the interassay CVs were < 6% for dabigatran and < 9% for rivaroxaban. Inaccuracy was < 5% for both substances. The mean recovery was 104.5% (range 83.8-113.0% for dabigatran and 87.0% (range 73.6-105.4% for rivaroxaban. No significant ion suppressions were detected at the elution times of dabigatran or rivaroxaban. Both coagulation inhibitors were stable in citrate plasma at -20°C, 4°C and even at RT for at

  19. Evaluating the Effects of Maintenance Resource Management (MRM) Interventions in Airline Safety

    Science.gov (United States)

    1998-02-01

    The present paper seeks to describe and validate the effectiveness of five change programs (generically termed Maintenance Resource Management, or "MRM"). The activities evaluated here are in the middle stages of an ongoing MRM training program, or t...

  20. Multiple Reaction Monitoring for quantitative laccase kinetics by LC-MS

    DEFF Research Database (Denmark)

    Perna, Valentina; Agger, Jane W.; Holck, Jesper

    2018-01-01

    as substrates to assess enzyme kinetics by HPLC-MS on two fungal laccases Trametes versicolor laccase, Tv and Ganoderma lucidum laccase, Gl. The method allowed accurate kinetic measurements and detailed insight into the product profiles of both laccases. Both Tv and Gl laccase are active...

  1. PChopper: high throughput peptide prediction for MRM/SRM transition design

    Directory of Open Access Journals (Sweden)

    Huang Jeffrey T-J

    2011-08-01

    Full Text Available Abstract Background The use of selective reaction monitoring (SRM based LC-MS/MS analysis for the quantification of phosphorylation stoichiometry has been rapidly increasing. At the same time, the number of sites that can be monitored in a single LC-MS/MS experiment is also increasing. The manual processes associated with running these experiments have highlighted the need for computational assistance to quickly design MRM/SRM candidates. Results PChopper has been developed to predict peptides that can be produced via enzymatic protein digest; this includes single enzyme digests, and combinations of enzymes. It also allows digests to be simulated in 'batch' mode and can combine information from these simulated digests to suggest the most appropriate enzyme(s to use. PChopper also allows users to define the characteristic of their target peptides, and can automatically identify phosphorylation sites that may be of interest. Two application end points are available for interacting with the system; the first is a web based graphical tool, and the second is an API endpoint based on HTTP REST. Conclusions Service oriented architecture was used to rapidly develop a system that can consume and expose several services. A graphical tool was built to provide an easy to follow workflow that allows scientists to quickly and easily identify the enzymes required to produce multiple peptides in parallel via enzymatic digests in a high throughput manner.

  2. Tools and Techniques for Evaluating the Effects of Maintenance Resource Management (MRM) in Air Safety

    Science.gov (United States)

    Taylor, James C.

    2002-01-01

    This research project was designed as part of a larger effort to help Human Factors (HF) implementers, and others in the aviation maintenance community, understand, evaluate, and validate the impact of Maintenance Resource Management (MRM) training programs, and other MRM interventions; on participant attitudes, opinions, behaviors, and ultimately on enhanced safety performance. It includes research and development of evaluation methodology as well as examination of psychological constructs and correlates of maintainer performance. In particular, during 2001, three issues were addressed. First a prototype process for measuring performance was developed and used. Second an automated calculator was developed to aid the HF implementer user in analyzing and evaluating local survey data. These results include being automatically compared with the experience from all MRM programs studied since 1991. Third the core survey (the Maintenance Resource Management Technical Operations Questionnaire, or 'MRM/TOQ') was further developed and tested to include topics of added relevance to the industry.

  3. The color removal of dye wastewater by magnesium chloride/red mud (MRM) from aqueous solution.

    Science.gov (United States)

    Wang, Qi; Luan, Zhaokun; Wei, Ning; Li, Jin; Liu, Chengxi

    2009-10-30

    In this study, the MgCl2/red mud system (MRM) was used to investigate the color removal efficiency of dye solutions. Parameters such as the effect of the dosage of red mud (RM) and MgCl2 have been studied. The effect of pH on the conversion rate of Mg2+ has also been studied. The color removal efficiency of MRM was compared with that of PAC/RM and PAC/NaOH. Meanwhile, the color removal efficiency of RM was compared with that of NaOH. The results show that the MRM system can remove more than 98% of the coloring material at a dosage of 25 g RM/L dye solution and a volume of 1.5 mL MgCl2/L dye solution in the decolorization process of reactive dye, acid dye and direct dye. The color removal efficiency was better than PAC/RM and PAC/NaOH system. The adsorption data have been analyzed using Langmuir and Freundlich isotherms. The results indicated that both models provide the best correlation of the experimental data. The decolorization mechanism of MRM was discussed, too. The MRM system was a viable alternative to some of the more conventional forms of chemical treatment of dye solutions and also provided another way to make use of industrial waste red mud.

  4. Evaluating Behaviorally Oriented Aviation Maintenance Resource Management (MRM) Training and Programs: Methods, Results, and Conclusions

    Science.gov (United States)

    Taylor, James C.; Thomas, Robert L., III

    2003-01-01

    Assessment of the impact of Aviation Resource Management Programs on aviation culture and performance has compelled a considerable body of research (Taylor & Robertson, 1995; Taylor, 1998; Taylor & Patankar, 2001). In recent years new methods have been applied to the problem of maintenance error precipitated by factors such as the need for self-assessment of communication and trust. The present study - 2002 -- is an extension of that past work. This research project was designed as the conclusion of a larger effort to help understand, evaluate and validate the impact of Maintenance Resource Management (MRM) training programs, and other MRM interventions on participant attitudes, opinions, behaviors, and ultimately on enhanced safety performance. It includes research and development of evaluation methodology as well as examination of psychological constructs and correlates of maintainer performance. In particular, during 2002, three issues were addressed. First, the evaluation of two (independent & different) MRM programs for changing behaviors was undertaken. In one case we were able to further apply the approach to measuring written communication developed during 2001 (Taylor, 2002; Taylor & Thomas, 2003). Second, the MRM/TOQ surveys were made available for completion on the internet. The responses from these on-line surveys were automatically linked to a results calculator (like the one developed and described in Taylor, 2002) to aid industry users in analyzing and evaluating their local survey data on the internet. Third, the main trends and themes from our research about MRM programs over the past dozen years were reviewed.

  5. Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Tujin; Su, Dian; Liu, Tao; Tang, Keqi; Camp, David G.; Qian, Weijun; Smith, Richard D.

    2012-04-01

    Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

  6. Defective mitochondrial rRNA methyltransferase MRM2 causes MELAS-like clinical syndrome.

    Science.gov (United States)

    Garone, Caterina; D'Souza, Aaron R; Dallabona, Cristina; Lodi, Tiziana; Rebelo-Guiomar, Pedro; Rorbach, Joanna; Donati, Maria Alice; Procopio, Elena; Montomoli, Martino; Guerrini, Renzo; Zeviani, Massimo; Calvo, Sarah E; Mootha, Vamsi K; DiMauro, Salvatore; Ferrero, Ileana; Minczuk, Michal

    2017-11-01

    Defects in nuclear-encoded proteins of the mitochondrial translation machinery cause early-onset and tissue-specific deficiency of one or more OXPHOS complexes. Here, we report a 7-year-old Italian boy with childhood-onset rapidly progressive encephalomyopathy and stroke-like episodes. Multiple OXPHOS defects and decreased mtDNA copy number (40%) were detected in muscle homogenate. Clinical features combined with low level of plasma citrulline were highly suggestive of mitochondrial encephalopathy, lactic acidosis and stroke-like episodes (MELAS) syndrome, however, the common m.3243 A > G mutation was excluded. Targeted exome sequencing of genes encoding the mitochondrial proteome identified a damaging mutation, c.567 G > A, affecting a highly conserved amino acid residue (p.Gly189Arg) of the MRM2 protein. MRM2 has never before been linked to a human disease and encodes an enzyme responsible for 2'-O-methyl modification at position U1369 in the human mitochondrial 16S rRNA. We generated a knockout yeast model for the orthologous gene that showed a defect in respiration and the reduction of the 2'-O-methyl modification at the equivalent position (U2791) in the yeast mitochondrial 21S rRNA. Complementation with the mrm2 allele carrying the equivalent yeast mutation failed to rescue the respiratory phenotype, which was instead completely rescued by expressing the wild-type allele. Our findings establish that defective MRM2 causes a MELAS-like phenotype, and suggests the genetic screening of the MRM2 gene in patients with a m.3243 A > G negative MELAS-like presentation. © The Author 2017. Published by Oxford University Press.

  7. Quantitative and Selective Analysis of Feline Growth Related Proteins Using Parallel Reaction Monitoring High Resolution Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Mårten Sundberg

    Full Text Available Today immunoassays are widely used in veterinary medicine, but lack of species specific assays often necessitates the use of assays developed for human applications. Mass spectrometry (MS is an attractive alternative due to high specificity and versatility, allowing for species-independent analysis. Targeted MS-based quantification methods are valuable complements to large scale shotgun analysis. A method referred to as parallel reaction monitoring (PRM, implemented on Orbitrap MS, has lately been presented as an excellent alternative to more traditional selected reaction monitoring/multiple reaction monitoring (SRM/MRM methods. The insulin-like growth factor (IGF-system is not well described in the cat but there are indications of important differences between cats and humans. In feline medicine IGF-I is mainly analyzed for diagnosis of growth hormone disorders but also for research, while the other proteins in the IGF-system are not routinely analyzed within clinical practice. Here, a PRM method for quantification of IGF-I, IGF-II, IGF binding protein (BP -3 and IGFBP-5 in feline serum is presented. Selective quantification was supported by the use of a newly launched internal standard named QPrEST™. Homology searches demonstrated the possibility to use this standard of human origin for quantification of the targeted feline proteins. Excellent quantitative sensitivity at the attomol/μL (pM level and selectivity were obtained. As the presented approach is very generic we show that high resolution mass spectrometry in combination with PRM and QPrEST™ internal standards is a versatile tool for protein quantitation across multispecies.

  8. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  9. A one-year monitoring of nicotine use in sport: frontier between potential performance enhancement and addiction issues.

    Science.gov (United States)

    Marclay, François; Grata, Elia; Perrenoud, Laurent; Saugy, Martial

    2011-12-10

    Tobacco consumption is a global epidemic responsible for a vast burden of disease. With pharmacological properties sought-after by consumers and responsible for addiction issues, nicotine is the main reason of this phenomenon. Accordingly, smokeless tobacco products are of growing popularity in sport owing to potential performance enhancing properties and absence of adverse effects on the respiratory system. Nevertheless, nicotine does not appear on the 2011 World Anti-Doping Agency (WADA) Prohibited List or Monitoring Program by lack of a comprehensive large-scale prevalence survey. Thus, this work describes a one-year monitoring study on urine specimens from professional athletes of different disciplines covering 2010 and 2011. A method for the detection and quantification of nicotine, its major metabolites (cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide) and minor tobacco alkaloids (anabasine, anatabine and nornicotine) was developed, relying on ultra-high pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC-TQ-MS/MS). A simple and fast dilute-and-shoot sample treatment was performed, followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. After method validation, assessing the prevalence of nicotine consumption in sport involved analysis of 2185 urine samples, accounting for 43 different sports. Concentrations distribution of major nicotine metabolites, minor nicotine metabolites and tobacco alkaloids ranged from 10 (LLOQ) to 32,223, 6670 and 538 ng/mL, respectively. Compounds of interest were detected in trace levels in 23.0% of urine specimens, with concentration levels corresponding to an exposure within the last three days for 18.3% of samples. Likewise, hypothesizing conservative concentration limits for active nicotine consumption prior and/or during

  10. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    Science.gov (United States)

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  11. The challenge and countermeasure for radioactivity monitor in ocean--the reflection derived from Fukushima nuclear power plant accident

    International Nuclear Information System (INIS)

    Liu Guangshan

    2014-01-01

    Environmental radioactivity monitor (ERM) follows with interest raising level, sink and transportation of radioactive materials in the environment. There are two kinds of challenges for marine radioactivity monitor (MRM), for which one concerned with facilities and methods that lead the very difficult measurement of MRM. Up to now, the bulk of sample must collected and prepared for most MRM by radiometry (counting method) and long acquisition period is needed. The long time from sampling to derived results postponed the time of the scientists and government officials learning contamination distribution information. Developing accelerator mass spectrometry (AMS) can overcome above difficulty because AMS method need one tenth of sample and one tenth measuring time needed by radiometric method. The second challenge is lack of the behavior research of radionuclide in the ocean. In the ocean, radionuclide behavior is constrained by physical and biogeochemical process, following that the radionuclides are transported from released sea area to where far from source area, from upper water to deep and bottom waters, and buried to sediment. There are some reports about radionuclide transportation with physical oceanographical process, but few paper about radionuclide biogeochemistry has been found. Lesser theory knowledge and lesser investigation data make scientists worked on MRM puzzling. The radionuclide behavior in the ocean can be studied by the method used in marine biogeochemistry. (author)

  12. 3D-MR myelography (3D-MRM) for the diagnosis of lumbal nerve root compression syndrome. A comparison with conventional myelography

    International Nuclear Information System (INIS)

    Eberhardt, K.E.W.; Hollenbach, H.P.; Huk, W.J.

    1994-01-01

    65 patients with nerve root compression syndrome were examined using a new type of MR-technique, which is comparable to the conventional X-ray myelography. The results of the prospective case study were compared with previous clinical experiences (1). For the examinations a 1.0 T whole body MR-system (Siemens Magnetom Impact) was used. A strong T 2 *-weighted 3D-FISP sequence (TR=73 ms, TE=21 ms, α=7 ) was applied in sagittal orientation using a circularly polarized oval spine coil. To obtain fat suppression a frequency selective 1-3-3-1 prepulse was applied prior to the imaging sequence. The acquired 3D-data set was evaluated using a Maximum Intensity Projection (MIP) program. Our results confirmed earlier experiences which showed that the diagnostic sensitivity of 3D-MR myelography (3D-MRM) is comparable to that of conventional X-ray myelography. In cases of severe spinal canal stenosis and spondylolisthesis, and in cases of postoperative scar tissue with nerve root compressions, the sensitivity of the 3D-MRM is higher as compared to that of conventional X-ray myelography. (orig.) [de

  13. Investigation of the subcellular architecture of L7 neurons of Aplysia californica using magnetic resonance microscopy (MRM) at 7.8 microns.

    Science.gov (United States)

    Lee, Choong H; Flint, Jeremy J; Hansen, Brian; Blackband, Stephen J

    2015-06-10

    Magnetic resonance microscopy (MRM) is a non-invasive diagnostic tool which is well-suited to directly resolve cellular structures in ex vivo and in vitro tissues without use of exogenous contrast agents. Recent advances in its capability to visualize mammalian cellular structure in intact tissues have reinvigorated analytical interest in aquatic cell models whose previous findings warrant up-to-date validation of subcellular components. Even if the sensitivity of MRM is less than other microscopic technologies, its strength lies in that it relies on the same image contrast mechanisms as clinical MRI which make it a unique tool for improving our ability to interpret human diagnostic imaging through high resolution studies of well-controlled biological model systems. Here, we investigate the subcellular MR signal characteristics of isolated cells of Aplysia californica at an in-plane resolution of 7.8 μm. In addition, direct correlation and positive identification of subcellular architecture in the cells is achieved through well-established histology. We hope this methodology will serve as the groundwork for studying pathophysiological changes through perturbation studies and allow for development of disease-specific cellular modeling tools. Such an approach promises to reveal the MR contrast changes underlying cellular mechanisms in various human diseases, for example in ischemic stroke.

  14. Magnetic resonance microscopy for monitoring osteogenesis in tissue-engineered construct in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huihui [Bioengineering Department (MC 063), University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607-7052 (United States); Othman, Shadi F [Bioengineering Department (MC 063), University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607-7052 (United States); Hong Liu [Bioengineering Department (MC 063), University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607-7052 (United States); Peptan, Ioana A [Bioengineering Department (MC 063), University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607-7052 (United States); Magin, Richard L [Bioengineering Department (MC 063), University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607-7052 (United States)

    2006-02-07

    Magnetic resonance microscopy (MRM) is used to monitor osteogenesis in tissue-engineered constructs. Measurements of the developing tissue's MR relaxation times (T{sub 1} and T{sub 2}), apparent diffusion coefficient (ADC) and elastic shear modulus were conducted over a 4-week growth period using an 11.74 T Bruker spectrometer with an imaging probe adapted for MR elastography (MRE). Both the relaxation times and the ADC show a statistically significant decrease after only one week of tissue development while the tissue stiffness increases progressively during the first two weeks of in vitro growth. The measured MR parameters are correlated with histologically monitored osteogenic tissue development. This study shows that MRM can provide quantitative data with which to characterize the growth and development of tissue-engineered bone.

  15. Early Detection of Cancer by Affinity Mass Spectrometry-Set Aside funds — EDRN Public Portal

    Science.gov (United States)

    A.   RATIONALE The recent introduction of multiple reaction monitoring capabilities offers unprecedented capability to the research arsenal available to protein based biomarker discovery. Specific to the discovery process this technology offers an ability to monitor specific protein changes in concentration and/or post-translational modification. The ability to accurately confirm specific biomarkers in a sensitive and reproducible manner is critical to the confirmation and pre-validation process. We are proposing two collaborative studies that promise to develop Multiple Reaction Monitoring (MRM) work flows for the biomarker scientific community and specifically for EDRN. B.   GOALS The overall goal for this proposal is the identification of protein biomarkers that can be associated with prostate cancer detection. The underlying goal is the application of a novel technological approach aided by MRM toward biomarker discovery. An additional goal will be the dissemination of knowledge gained from these studies EDRN wide.

  16. Changes in the expression of N- and O-glycopeptides in patients with colorectal cancer and hepatocellular carcinoma quantified by full-MS scan FT-ICR and multiple reaction monitoring

    Czech Academy of Sciences Publication Activity Database

    Darebná, P.; Novák, Petr; Kučera, R.; Topolčan, O.; Sanda, M.; Goldman, R.; Pompach, Petr

    2017-01-01

    Roč. 153, SI (2017), s. 44-52 ISSN 1874-3919 Grant - others:Ministerstvo pro místní rozvoj(CZ) CZ2.16./3.1.00/24023 Institutional support: RVO:61388971 Keywords : Mass spectrometry * Glycomics * FT-ICR Subject RIV: EE - Microbiology, Virology OBOR OECD: Microbiology Impact factor: 3.914, year: 2016

  17. Particle correlations in high-multiplicity reactions

    International Nuclear Information System (INIS)

    Hayot, Fernand.

    1976-01-01

    A comprehensive review of the results obtained in the study of short range correlations in high-multiplicity events is presented: introduction of the fundamental short-range order hypothesis, introduction of clusters in nondiffractive events (only the production of identical, independent, and neutral clusters was considered); search for short range dynamical effects between particles coming from the decay of a same cluster by studying two-particle rapidity correlations in inclusive and semi-inclusive experiments; study of transverse momentum correlations [fr

  18. Data from a targeted proteomics approach to discover biomarkers in saliva for the clinical diagnosis of periodontitis

    Directory of Open Access Journals (Sweden)

    V. Orti

    2018-06-01

    Full Text Available This study focused on the search for new biomarkers based on liquid chromatography-multiple reaction monitoring (LC-MRM proteomics profiling of whole saliva from patients with periodontitis compared to healthy subjects. The LC-MRM profiling approach is a new and innovative method that has already been validated for the absolute and multiplexed quantification of biomarkers in several diseases. The dataset for this study was produced using LC-MRM to monitor protein levels in a multiplex assay, it provides clinical information on salivary biomarkers of periodontitis. The data presented here is an extension of our recently published research article (Mertens et al., 2017 [1]. Keywords: Clinical chemistry, Mass spectrometry, Proteomics, Saliva biochemistry, Oral disease, Periodontitis

  19. Targeting MUC1 mediated tumor stromal metabolic interaction in Triple negative Breast Cancer

    Science.gov (United States)

    2016-11-01

    were suspended in 200 µl of LC-MS grade water and centrifuged to collect the water - soluble supernatants. The combined supernatants were concentrated...suspended in equal volumes of LC-MS grade water and 10 µl were utilized for LC-MS/MS using multiple reaction monitoring (MRM) method described...AcCoA), α-ketoglutarate (α-KG), solute carrier family 1 member 5 (SLC1A5), tricarboxyic acid cycle (TCA cycle), transcription factor (TF) and

  20. Targeting MUC1-Mediated Tumor-Stromal Metabolic Interaction in Triple-Negative Breast Cancer

    Science.gov (United States)

    2016-11-01

    were suspended in 200 µl of LC-MS grade water and centrifuged to collect the water - soluble supernatants. The combined supernatants were concentrated...suspended in equal volumes of LC-MS grade water and 10 µl were utilized for LC-MS/MS using multiple reaction monitoring (MRM) method described...AcCoA), α-ketoglutarate (α-KG), solute carrier family 1 member 5 (SLC1A5), tricarboxyic acid cycle (TCA cycle), transcription factor (TF) and

  1. Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography–Multiple-Reaction–Monitoring Mass Spectrometry

    Science.gov (United States)

    Agger, Sean A.; Marney, Luke C.; Hoofnagle, Andrew N.

    2011-01-01

    BACKGROUND If liquid-chromatography–multiple-reaction–monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed a multiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS We used PeptideAtlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 × immunoassay – 36.6; Sx|y = 10.3 for apoA-I and LC-MRM/MS = 1.21 × immunoassay + 7.0; Sx|y = 7.9 for apoB). CONCLUSIONS Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. PMID:20923952

  2. Food Forensics: Using Mass Spectrometry To Detect Foodborne Protein Contaminants, as Exemplified by Shiga Toxin Variants and Prion Strains.

    Science.gov (United States)

    Silva, Christopher J

    2018-06-13

    Food forensicists need a variety of tools to detect the many possible food contaminants. As a result of its analytical flexibility, mass spectrometry is one of those tools. Use of the multiple reaction monitoring (MRM) method expands its use to quantitation as well as detection of infectious proteins (prions) and protein toxins, such as Shiga toxins. The sample processing steps inactivate prions and Shiga toxins; the proteins are digested with proteases to yield peptides suitable for MRM-based analysis. Prions are detected by their distinct physicochemical properties and differential covalent modification. Shiga toxin analysis is based on detecting peptides derived from the five identical binding B subunits comprising the toxin. 15 N-labeled internal standards are prepared from cloned proteins. These examples illustrate the power of MRM, in that the same instrument can be used to safely detect and quantitate protein toxins, prions, and small molecules that might contaminate our food.

  3. Murine respiratory mycoplasmosis (MRM) in C57BL/6N and C3H/HeN mice: strain differences in early host responses and exacerbation by nitrogen dioxide

    International Nuclear Information System (INIS)

    Parker, R.F.

    1987-01-01

    The studies reported here used genetic differences in susceptibility of C57BL/6N and C3H/HeN mice and exacerbation of the disease by nitrogen dioxide (NO 2 ) as tools in assessing the role of early host responses in the pathogenesis of MRM. The two strains did not differ in susceptibility to infection, but C3H/HeN mice were more susceptible to and had increased severity of lung lesions 14 days after intranasal inoculation as determined by 50% biological endpoints and morphometric analysis of tissues. Exposure to NO 2 for 4 hours prior to exposure to infectious aerosols exacerbated murine respiratory mycoplasmosis (MRM) by 7 days after exposure in both mouse strains. NO 2 appeared to affect host lung defense mechanisms responsible for limiting mycoplasmal growth in the lungs. The NO 2 exposure concentration required for this effect varied with the genetic background of the host, the dose of mycoplasmas administered, and the endpoint measured. Pulmonary clearance of radiolabeled M. pulmonis was determined in both mouse strains, and in C57BL/6N mice exposed to NO 2

  4. Multiplexed mass spectrometry monitoring of biomarker candidates for osteoarthritis.

    Science.gov (United States)

    Fernández-Puente, Patricia; Calamia, Valentina; González-Rodríguez, Lucía; Lourido, Lucía; Camacho-Encina, María; Oreiro, Natividad; Ruiz-Romero, Cristina; Blanco, Francisco J

    2017-01-30

    The methods currently available for the diagnosis and monitoring of osteoarthritis (OA) are very limited and lack sensitivity. Being the most prevalent rheumatic disease, one of the most disabling pathologies worldwide and currently untreatable, there is a considerable interest pointed in the verification of specific biological markers for improving its diagnosis and disease progression studies. Considering the remarkable development of targeted proteomics methodologies in the frame of the Human Proteome Project, the aim of this work was to develop and apply a MRM-based method for the multiplexed analysis of a panel of 6 biomarker candidates for OA encoded by the Chromosome 16, and another 8 proteins identified in previous shotgun studies as related with this pathology, in specimens derived from the human joint and serum. The method, targeting 35 different peptides, was applied to samples from human articular chondrocytes, healthy and osteoarthritic cartilage, synovial fluid and serum. Subsequently, a verification analysis of the biomarker value of these proteins was performed by single point measurements on a set of 116 serum samples, leading to the identification of increased amounts of Haptoglobin and von Willebrand Factor in OA patients. Altogether, the present work provides a tool for the multiplexed monitoring of 14 biomarker candidates for OA, and verifies for the first time the increased amount of two of these circulating markers in patients diagnosed with this disease. We have developed an MRM method for the identification and relative quantification of a panel of 14 protein biomarker candidates for osteoarthritis. This method has been applied to analyze human articular chondrocytes, articular cartilage, synovial fluid, and finally a collection of 116 serum samples from healthy controls and patients suffering different degrees of osteoarthritis, in order to verify the biomarker usefulness of the candidates. HPT and VWF were validated as increased in OA

  5. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  6. A highly sensitive method for quantification of iohexol

    DEFF Research Database (Denmark)

    Schulz, A.; Boeringer, F.; Swifka, J.

    2014-01-01

    -chromatography-electrospray-massspectrometry (LC-ESI-MS) approach using the multiple reaction monitoring mode for iohexol quantification. In order to test whether a significantly decreased amount of iohexol is sufficient for reliable quantification, a LC-ESI-MS approach was assessed. We analyzed the kinetics of iohexol in rats after application...... of different amounts of iohexol (15 mg to 150 1.tg per rat). Blood sampling was conducted at four time points, at 15, 30, 60, and 90 min, after iohexol injection. The analyte (iohexol) and the internal standard (iotha(amic acid) were separated from serum proteins using a centrifugal filtration device...... with a cut-off of 3 kDa. The chromatographic separation was achieved on an analytical Zorbax SB C18 column. The detection and quantification were performed on a high capacity trap mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. Furthermore, using real-time polymerase...

  7. [Analysis of saponins from panax notoginseng using pressurized solvent extraction coupled with liquid chromatography-electrospray mass spectrum].

    Science.gov (United States)

    Wan, Jianbo; Li, Changming; Li, Shaopin; Kong, Lingyi; Wang, Yitao

    2005-10-01

    To establish a method for qualitative analysis of saponins from Panax notoginseng using pressurized solvent extraction coupled with LC-ESI-MS. The PSE technology was applied to the process of extraction for Panax notoginseng, and the negative ion detection and multiple reaction monitoring model were used. The saponins were investigated based on total ion chromatogram (TIC) and MRM chromatogram. According to the fragment character of saponins, the molecular weight and their structures could be identified. The method can be used for qualitative analysis of saponins from Panax notoginseng.

  8. New sensitive high-performance liquid chromatography-tandem mass spectrometry method for the detection of horse and pork in halal beef.

    Science.gov (United States)

    von Bargen, Christoph; Dojahn, Jörg; Waidelich, Dietmar; Humpf, Hans-Ulrich; Brockmeyer, Jens

    2013-12-11

    The accidental or fraudulent blending of meat from different species is a highly relevant aspect for food product quality control, especially for consumers with ethical concerns against species, such as horse or pork. In this study, we present a sensitive mass spectrometrical approach for the detection of trace contaminations of horse meat and pork and demonstrate the specificity of the identified biomarker peptides against chicken, lamb, and beef. Biomarker peptides were identified by a shotgun proteomic approach using tryptic digests of protein extracts and were verified by the analysis of 21 different meat samples from the 5 species included in this study. For the most sensitive peptides, a multiple reaction monitoring (MRM) method was developed that allows for the detection of 0.55% horse or pork in a beef matrix. To enhance sensitivity, we applied MRM(3) experiments and were able to detect down to 0.13% pork contamination in beef. To the best of our knowledge, we present here the first rapid and sensitive mass spectrometrical method for the detection of horse and pork by use of MRM and MRM(3).

  9. Personnel monitoring

    International Nuclear Information System (INIS)

    1965-01-01

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  10. Mobility Monitor

    DEFF Research Database (Denmark)

    Schæbel, Anne-Lise; Dybbro, Karina Løvendahl; Andersen, Lisbeth Støvring

    2015-01-01

    Undersøgelse af digital monitorering af plejehjemsbeboeres vendinger under søvn på Fremtidens Plejehjem, Nørresundby......Undersøgelse af digital monitorering af plejehjemsbeboeres vendinger under søvn på Fremtidens Plejehjem, Nørresundby...

  11. Personnel monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-12-31

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  12. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  13. Monitoring Hadoop

    CERN Document Server

    Singh, Gurmukh

    2015-01-01

    This book is useful for Hadoop administrators who need to learn how to monitor and diagnose their clusters. Also, the book will prove useful for new users of the technology, as the language used is simple and easy to grasp.

  14. Treaty Monitoring

    DEFF Research Database (Denmark)

    Canty, M.; Jasani, B.; Lingenfelder, I.

    2009-01-01

    of remote sensing technologies. The book therefore comprises management aspects (issues and priorities of security research, crisis response), applied methodologies and process chains (treaty monitoring, estimation of population densities and characteristics, border permeability models, damage assessment...... companies, national research institutions and international organizations, all of whom were brought together under the aegis of the European research project GMOSS (Global Monitoring for Security and Stability). This book is tailored for the scientific community that deals with the application of EO data...... of civil security. Written for: Scientists, researchers in spatial sciences as well as practitioners, politicians, decision makers at NGO's in the field of security, crisis management, risk assessment and vulnerability....

  15. Monitoring apparatus

    International Nuclear Information System (INIS)

    Keats, A.B.

    1981-01-01

    An improved monitoring apparatus for use with process plants, such as nuclear reactors, is described. System failure in the acquisition of data from the plant, owing to stuck signals, is avoided by arranging input signals from transducers in the plant in a test pattern. (U.K.)

  16. Monitor 1979

    International Nuclear Information System (INIS)

    Grisham, D.L.; Ekberg, E.L.; Lambert, J.E.; Meyer, R.E.; Stroik, P.J.; Wickham, M.D.

    1979-01-01

    The status, improvements, and accomplishments of the Monitor remote-handling system previously reported are updated. It also outlines the goals for the future to improve the efficiency and speed of remote-maintenance operations at the Clinton P. Anderson Meson Physics Facility

  17. Monitoring programme

    International Nuclear Information System (INIS)

    1994-06-01

    Her Majesty's Inspectorate of Pollution's 1992 report on its programme of monitoring radioactive substances is presented. Site operators' returns are verified and the report provides independent data on the environmental impact of authorized disposal of radioactive wastes. Radiation doses which may have been received by members of the public, fall well below the International Commission for Radiological Protection's (ICRP) recommended annual doses. (UK)

  18. Fingerprinting Deepwater Horizon Oil in the northern Gulf of Mexico using biomarkers and Gas Chromatography-Triple Quadrupole Mass Spectrometry (GC/MS/MS)

    Science.gov (United States)

    Adhikari, P. L.; Overton, E. B.; Maiti, K.; Wong, R. L.

    2016-02-01

    Petroleum biomarkers such as hopanes, steranes, and triaromatic steroids are more persistent than alkanes and aromatic compounds. Thus, they are often used to track spilled oil in the environments and as a proxy for weathering processes. The present study utilizes water samples, suspended and sinking particles, and seafloor sediments collected during 2011-2013 from various locations of the northern Gulf of Mexico with wide range of contaminated oil for Deepwater Horizon (DWH) oil fingerprinting. The MC252 source oil along with the samples collected in this study were analyzed using a gas chromatography coupled with a triple quadrupole mass spectrometry (GC/MS/MS) in Multiple Reaction Monitoring (MRM) mode and the results were compared with results from commonly used GC/MS selective ion monitoring (SIM) method. The results indicate that the MRM method separates interfering ions from interfering compounds and can be a powerful analytical strategy for a reliable identification and determination of trace levels of biomarkers in complex matrices. Source indicators such as the MRM fragment ion chromatograms of the biomarkers and their diagnostic ratios in samples were compared with the MC252 source oil. The preliminary results show that the biomarkers were below detection limits in dissolved samples. However, in few particulate and seafloor sediment samples, primarily from the immediate vicinity of the Macondo wellhead, contained their patterns. The results also illustrate that these biomarker compounds have been weathered within 1-3 years following the oil spill, and their DWH oil signature in some of these samples reflects this weathering.

  19. Energy Monitoring

    DEFF Research Database (Denmark)

    Hansen, Claus T.; Madsen, Dines; Christiensen, Thomas

    Energy measurement has become an important aspect of our daily lives since we have learned that energy consumption, is one of the main source of global warming. Measuring instruments varies from a simple watt-meter to more sophisticated microprocessor control devices. The negative effects...... that fossil fuels induce on our environment has forced us to research renewable energy such as sunlight, wind etc. This new environmental awareness has also helped us to realize the importance of monitoring and controlling our energy use. The main purpose in this research is to introduce a more sophisticated...... but affordable way to monitor energy consumption of individuals or groups of home appliances. By knowing their consumption the utilization can be regulated for more efficient use. A prototype system has been constructed to demonstrate our idea....

  20. Personal monitoring

    International Nuclear Information System (INIS)

    1995-01-01

    Sources of ionizing radiation have innumerable applications in the workplace. The potential exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Module explains the basic terminology associated with personal monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Module can only be provided by qualified experts

  1. Sewage Monitors

    Science.gov (United States)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  2. Material monitoring

    International Nuclear Information System (INIS)

    Kotter, W.; Zirker, L.; Hancock, J.A.

    1995-01-01

    Waste Reduction Operations Complex (WROC) facilities are located at the Idaho National Engineering Laboratory (INEL). The overall goal for the Pollution Prevention/Waste Minimization Unit is to identify and establish the correct amount of waste generated so that it can be reduced. Quarterly, the INEL Pollution Prevention (P2) Unit compares the projected amount of waste generated per process with the actual amount generated. Examples of waste streams that would be addresses for our facility would include be are not limited to: Maintenance, Upgrades, Office and Scrap Metal. There are three potential sources of this variance: inaccurate identification of those who generate the waste; inaccurate identification of the process that generates the waste; and inaccurate measurement of the actual amount generated. The Materials Monitoring Program was proposed to identify the sources of variance and reduce the variance to an acceptable level. Prior to the implementation of the Material Monitoring Program, all information that was gathered and recorded was done so through an informal estimation of waste generated by various personnel concerned with each processes. Due to the inaccuracy of the prior information gathering system, the Material Monitoring Program was established. The heart of this program consists of two main parts. In the first part potential waste generators provide information on projected waste generation process. In the second part, Maintenance, Office, Scrap Metal and Facility Upgrade wastes from given processes is disposed within the appropriate bin dedicated to that process. The Material Monitoring Program allows for the more accurate gathering of information on the various waste types that are being generated quarterly

  3. Individual monitoring

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series which has been designed to provide guidance on radiological protection for employers, Radiation Protection Officers, managers and other technically competent persons who have a responsibility to ensure the safety of employees working with ionizing radiation. The Manual may be used together with the appropriate IAEA Practical Radiation Safety Manual to provide adequate training, instruction or information on individual monitoring for all employees engaged in work with ionizing radiations. Sources of ionizing radiation have a large number of applications in the workplace. The exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Manual explains the basic terminology associated with individual monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Manual can only be provided by qualified experts

  4. Technology monitoring; Technologie-Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eicher, H.; Rigassi, R. [Eicher und Pauli AG, Liestal (Switzerland); Ott, W. [Econcept AG, Zuerich (Switzerland)

    2003-07-01

    This study made for the Swiss Federal Office of Energy (SFOE) examines ways of systematically monitoring energy technology development and the cost of such technologies in order to pave the way to a basis for judging the economic development of new energy technologies. Initial results of a survey of the past development of these technologies are presented and estimates are made of future developments in the areas of motor-based combined heat and power systems, fuel-cell heating units for single-family homes and apartment buildings, air/water heat pumps for new housing projects and high-performance thermal insulation. The methodology used for the monitoring and analysis of the various technologies is described. Tables and diagrams illustrate the present situation and development potential of various fields of technology.

  5. Ammonia Monitor

    Science.gov (United States)

    Sauer, Richard L. (Inventor); Akse, James R. (Inventor); Thompson, John O. (Inventor); Atwater, James E. (Inventor)

    1999-01-01

    Ammonia monitor and method of use are disclosed. A continuous, real-time determination of the concentration of ammonia in an aqueous process stream is possible over a wide dynamic range of concentrations. No reagents are required because pH is controlled by an in-line solid-phase base. Ammonia is selectively transported across a membrane from the process stream to an analytical stream to an analytical stream under pH control. The specific electrical conductance of the analytical stream is measured and used to determine the concentration of ammonia.

  6. Oscillator monitor

    International Nuclear Information System (INIS)

    McNeill, G.A.

    1981-01-01

    Present high-speed data acquisition systems in nuclear diagnostics use high-frequency oscillators to provide timing references for signals recorded on fast, traveling-wave oscilloscopes. An oscillator's sinusoidal wave shape is superimposed on the recorded signal with each cycle representing a fixed time increment. During data analysis the sinusoid is stripped from the signal, leaving a clean signal shape with known timing. Since all signal/time relationships are totally dependant upon working oscillators, these critical devices must have remote verification of proper operation. This manual presents the newly-developed oscillator monitor which will provide the required verification

  7. Luminosity monitor

    International Nuclear Information System (INIS)

    Underwood, D. G.

    1998-01-01

    Luminosity monitors are needed in each experiment doing spin physics at RHIC. They concentrate on the luminosity aspects here because, for example, with a 10 -3 raw asymmetry in an experiment, an error of 10 -4 in the luminosity is as significant as a 10% polarization error. Because luminosity is a property of how two beams overlap, the luminosity at an interaction region must be measured at that interaction region in order to be relevant to the experiment at that interaction region. The authors will have to do the physics and the luminosity measurements by using labels on the event sums according to the polarization labels on the colliding bunches. Most likely they will not have independent polarization measurement on each bunch, but only on all the filled bunches in a ring, or perhaps all the bunches that are actually used in an experiment. Most analyses can then be handled by using the nine combinations gotten from three kinds of bunches in each ring, +, - and empty bunches. The empty bunches are needed to measure beam-gas background, (and some, like six in a row, are needed for the beam abort). Much of the difficulty comes from the fact that they must use a physics process to represent the luminosity. This process must have kinematic and geometric cuts both to reduce systematics such as beam-gas backgrounds, and to make it representative of the part of the interaction diamond from which the physics events come

  8. Contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alamares, A L [Philippine Nuclear Research Inst., Diliman, Quezon City (Philippines)

    1997-06-01

    By virture of Republic Act 2067, as amended the Philippine Atomic Energy Commission (PAEC), now renamed Philippine Nuclear Research Institute (PNRI) is the government agency charged with the regulations and control of radioactive materials in the Philippines. The protection against the hazards of non-ionizing radiation is being monitored by the Radiological Health Service (RHS) of the Department of Health pursuant to the provision of Presidental Decree 480. The RHS issues licenses for possession, handling, and use of x-ray machines and equipment, both industrial and medical, and provide radiation protection training to x-ray technologists and technicians. As part of its regulatory function, the PNRI is charged with the responsibility of assuring that the radiation workers and the public are protected from the hazards associated with the possession, handling, production, manufacturing, and the use of radioactive materials and atomic energy facilities in the Philippines. The protection of radiation workers from the hazards of ionizing radiation has always been a primary concern of PNRI and by limiting the exposure of radiation workers, the risk to population is kept to within acceptable level. In this paper, the following items are described: radiation protection program, radiation protection services, radiation control, and problems encountered/recommendation. (G.K.)

  9. Reactor monitor

    International Nuclear Information System (INIS)

    Takada, Tamotsu.

    1992-01-01

    The device of the present invention monitors a reactor so that each of the operations for the relocation of fuel assemblies and the withdrawal and the insertion of control rods upon exchange of fuel assemblies and control rods in the reactor. That is, when an operator conducts relocating operation by way of a fuel assembly operation section, the device of the present invention judges whether the operation indication is adequate or not, based on the information of control rod arrangement in a control rod memory section. When the operation indication is wrong, a stop signal is sent to a fuel assembly relocating device. Further, when the operator conducts control rod operation by way of a control rod operation section, the device of the present invention judges in the control rod withdrawal judging section, as to whether the operation indication given by the operator is adequate or not by comparing it with fuel assembly arrangement information. When the operation indication is wrong, a stop signal is sent to control rod drives. With such procedures, increase of nuclear heating upon occurrence of erroneous operation can be prevented. (I.S.)

  10. Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Hunter, S.W.; Gallegos, G.M.; Surano, K.A.; Lamson, K.C.; Tate, P.J.; Balke, B.K.; Biermann, A.H.; Hoppes, W.G.; Fields, B.C.; Gouveia, F.J.; Berger, R.L.; Miller, F.S.; Rueppel, D.W.; Sims, J.M.

    1992-04-01

    The primary tasks of the environmental monitoring section (EMS) Livermore National Laboratory (LLNL) are: effluent monitoring of air, sewer, and NPDES water. Surveillance monitoring of soil, vegetation and foodstuff, water, air particulate, and air tritium. Radiation monitoring, dose assessment, emergency response, quality assurance, and reporting. This report describes LLNL and the monitoring plan

  11. Development of web monitoring radiation area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon Jin; Lee, Jun Hee; Namkoong, Phil; Lee, Dong Hoon; Lee, Su Hong; Lee, Gun Bae

    2005-01-01

    Recently the increasing number of radioisotope industry and nuclear facility have ever raised the possibility of radiation safety accident. As such a result, radioisotope companies and nuclear facility operators have become to be much interested in radiation area monitoring for efficient radiation protection. At present, almost of the radiation area monitors which are imported products are outdated in aspect of their functions. Diversification of the monitoring work is urgently demanding additional functions to be added. Thus we have developed new-type digital area monitor which enables remote web monitoring with image and radiation dose rate value at distant places through using internet, the latest IT technology, and radiation measurement technology

  12. Monitoring Knowledge Base (MKB)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Monitoring Knowledge Base (MKB) is a compilation of emissions measurement and monitoring techniques associated with air pollution control devices, industrial...

  13. Simultaneous Determination of Antipsychotic Drugs and Their Active Metabolites by LC-MS-MS and its Application to Therapeutic Drug Monitoring.

    Science.gov (United States)

    Miroshnichenko, Igor I; Baymeeva, Natalia V

    2018-04-07

    A quantitative method was developed to support therapeutic drug monitoring of eight antipsychotic drugs: chlorpromazine, haloperidol, zuclopenthixol, clozapine, risperidone, quetiapine, aripiprazole or olanzapine and some active metabolites (dehydroaripiprazole, N-desmethylclozapine and 9-hydroxyrisperidone) in human serum. Separation of the compounds was achieved using a Zorbax SB-C18 (150 mm × 4.6 mm, 5 μm) column and mass-spectrometric detection in multiple reaction monitoring mode. Human blood samples were collected in vacutainer tubes and the analytes were extracted with methyl-tert-butyl ether. The lower limits of quantitation were equal 0.5-1 ng/mL for all analytes. The method was applied with success to serum samples from schizophrenic patients undergoing polypharmacy with two or more different antipsychotic drugs. Precision data, accuracy results were satisfactory, and no interference from other psychotropic drugs was found. Hence, the method is suitable for the TDM of the analytes in psychotic patients' serum.

  14. Monitor resultaten geluid 2000

    NARCIS (Netherlands)

    Jabben J; Potma CJM; Swart WJR; LLO

    2001-01-01

    As part of an enhanced effort in monitoring the environmental quality in 1999, the RIVM set up a noise monitoring programme. This programme forms part of the project, "Development of a monitoring system for noise and disturbance", which aims at establishing a number of permanent sites for monitoring

  15. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  16. Monitoring of transport contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of transport contamination is considered. A particularly thorough monitoring is recommended to be carried out in loading-unloading operations. The monitoring is performed when leaving loading-unloading site and zone under control and prior to preventive examination, technical service or repair. The method of monitoring of auto transport contamination with high-energy β-emitters by means of a special stand permitting the automation of the monitoring process is described [ru

  17. Environmental γ radiation monitor

    International Nuclear Information System (INIS)

    Qu Xiaopeng

    1993-01-01

    The environmental γ radiation monitor is a kind of dose or dose rate measuring devices, which can be used for monitoring environmental γ radiation around a nuclear site when normal or even abnormal events occur. The monitor is controlled by a single-chip microcomputer so that it can acquire synchronously the data from four detectors and transfer the data to a central computer. The monitor has good temperature property due to the technique of temperature correction. The monitor has been used in the environment monitoring vehicle for Qinshan Nuclear Power Plant

  18. Monitoring natural phytoplankton communities

    DEFF Research Database (Denmark)

    Haraguchi, L.; Jakobsen, H. H.; Lundholm, Nina

    2017-01-01

    The phytoplankton community can vary within hours (physiology) to years (climatic and anthropogenic responses), and monitoring at different timescales is relevant for understanding community functioning and assessing changes. However, standard techniques used in monitoring programmes are time...

  19. Beam position monitoring

    International Nuclear Information System (INIS)

    Shafer, R.E.

    1990-01-01

    Beam monitoring in accelerators is reviewed, with emphasis on the engineering aspects of the problem. Guidelines for monitor design are given. Advantages and disadvantages of various electrode designs and signal processing methods are reviewed

  20. USAID Colombia - Clearinghouse Monitor

    Data.gov (United States)

    US Agency for International Development — The Monitoring and Evaluation (M&E) Clearinghouse-Monitor is a web-based Information System that provides the Mission with information about the status and...

  1. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  2. Radiation protection and monitoring

    International Nuclear Information System (INIS)

    Thomas, P.

    1982-01-01

    The present paper deals with the following topics: - Radiological quantities and units - Principles of radiological protection - Limits of doses and activity uptake - Activity discharges and monitoring - Radiation exposure and its calculation - Environmental monitoring - Personnel dosimetry. (orig./RW)

  3. To monitor or not to monitor?: editorial

    International Nuclear Information System (INIS)

    Johns, T.F.

    1988-01-01

    After a brief discussion about results for occupational exposure in New Zealand and the UK, a short editorial raises a number of questions about personal dosimetry practice. These questions include whether the right people are being monitored and whether less attention should be paid to the monitoring of certain groups of workers who are occupationally exposed to external beta/gamma radiation, and more to the monitoring of workers or members of the general public who are exposed to higher doses from radon daughters, so as to focus attention on the areas where the largest savings in collective dose could be achieved. (U.K.)

  4. Inside the Monitor Model

    DEFF Research Database (Denmark)

    Carl, Michael; Dragsted, Barbara

    2012-01-01

    a “monitor model” according to which translators start with a literal default rendering procedure and where a monitor interrupts the default procedure when a problem occurs. This paper suggests an extension of the monitor model in which comprehension and production are processed in parallel by the default...

  5. Remote Monitoring Transparency Program

    International Nuclear Information System (INIS)

    Sukhoruchkin, V.K.; Shmelev, V.M.; Roumiantsev, A.N.

    1996-01-01

    The objective of the Remote Monitoring Transparency Program is to evaluate and demonstrate the use of remote monitoring technologies to advance nonproliferation and transparency efforts that are currently being developed by Russia and the United States without compromising the national security to the participating parties. Under a lab-to-lab transparency contract between Sandia National Laboratories (SNL) and the Kurchatov Institute (KI RRC), the Kurchatov Institute will analyze technical and procedural aspects of the application of remote monitoring as a transparency measure to monitor inventories of direct- use HEU and plutonium (e.g., material recovered from dismantled nuclear weapons). A goal of this program is to assist a broad range of political and technical experts in learning more about remote monitoring technologies that could be used to implement nonproliferation, arms control, and other security and confidence building measures. Specifically, this program will: (1) begin integrating Russian technologies into remote monitoring systems; (2) develop remote monitoring procedures that will assist in the application of remote monitoring techniques to monitor inventories of HEU and Pu from dismantled nuclear weapons; and (3) conduct a workshop to review remote monitoring fundamentals, demonstrate an integrated US/Russian remote monitoring system, and discuss the impacts that remote monitoring will have on the national security of participating countries

  6. BPA genetic monitoring - BPA Genetic Monitoring Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Initiated in 1989, this study monitors genetic changes associated with hatchery propagation in multiple Snake River sub-basins for Chinook salmon and steelhead. We...

  7. Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.

    Science.gov (United States)

    Di Donna, Leonardo; Taverna, Domenico; Indelicato, Serena; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio

    2017-08-15

    A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Rapid screening the alkaloids of poppy shell in hot pot condiment, beef noodle soup and seasoning by direct analysis in real time-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Baile; Gao, Lihong; Xie, Yingshuang; Zhou, Wei; Chen, Xiaofeng; Lei, Chunni; Zhang, Huan

    2017-07-08

    A direct analysis in real time tandem mass spectrometry (DART-MS/MS) method was established for quickly screening five illegally added alkaloids of poppy shell from the hot pot condiment, beef noodle soup and seasoning. The samples were extracted and purified by acetonitrile, and then injected under the conditions of ionization temperature of 300℃, grid electrode voltage of 150 V and sampling rate of 0.8 mm/s using DART in the positive ion mode. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. The method is simple and rapid, and can meet the requirement of rapid screening and analysis of large quantities of samples.

  9. Non-target screening of Allura Red AC photodegradation products in a beverage through ultra high performance liquid chromatography coupled with hybrid triple quadrupole/linear ion trap mass spectrometry.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Calabrese, Giorgio; Gennaro, Maria Carla; Marengo, Emilio

    2013-01-15

    The study deals with the identification of the degradation products formed by simulated sunlight photoirradiation in a commercial beverage that contains Allura Red AC dye. An UHPLC-MS/MS method, that makes use of hybrid triple quadrupole/linear ion trap, was developed. In the identification step the software tool information dependent acquisition (IDA) was used to automatically obtain information about the species present and to build a multiple reaction monitoring (MRM) method with the MS/MS fragmentation pattern of the species considered. The results indicate that the identified degradation products are formed from side-reactions and/or interactions among the dye and other ingredients present in the beverage (ascorbic acid, citric acid, sucrose, aromas, strawberry juice, and extract of chamomile flowers). The presence of aromatic amine or amide functionalities in the chemical structures proposed for the degradation products might suggest potential hazards to consumer health. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. A High-Throughput UHPLC-QqQ-MS Method for Polyphenol Profiling in Rosé Wines

    Directory of Open Access Journals (Sweden)

    Marine Lambert

    2015-04-01

    Full Text Available A rapid, sensitive and selective analysis method using Ultra High Performance Liquid Chromatography coupled to triple-quadrupole Mass Spectrometry (UHPLC-QqQ-MS has been developed for the quantification of polyphenols in rosé wines. The compound detection being based on specific MS transitions in Multiple Reaction Monitoring (MRM mode, the present method allows the selective quantification of up to 152 phenolic and two additional non-phenolic wine compounds in 30 min without sample purification or pre-concentration, even at low concentration levels. This method was repeatably applied to a set of 12 rosé wines and thus proved to be suitable for high-throughput and large-scale metabolomics studies.

  11. Metabolic profiling of Vitex agnus castus leaves, fruits and sprouts: analysis by LC/ESI/(QqQ)MS and (HR) LC/ESI/(Orbitrap)/MS n.

    Science.gov (United States)

    Mari, Angela; Montoro, Paola; D'Urso, Gilda; Macchia, Mario; Pizza, Cosimo; Piacente, Sonia

    2015-01-01

    Food supplements based on Vitex agnus castus L. (Verbenaceae) fruits, also known as chasteberry, are routinely used by women against somatic and psychic premenstrual symptoms such as depression, sadness or irritability. With the aim of highlighting the differences in the chemical profiles of cultivated fruits and different parts of wild plants (fruits, leaves and sprouts) of V. agnus castus, a method concerning with the quali-quantitative study of the derived hydroalcoholic extracts was carried out by using high-performance liquid chromatography coupled to electrospray negative ionization Orbitrap multicollisional high resolution mass spectrometry (LC/ESI/(Orbitrap)MS(n)) and high-performance liquid chromatography coupled to electrospray negative ionization triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MS) in multiple reaction monitoring (MRM) mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. The Spatial Distribution of Alkaloids in Psychotria prunifolia (Kunth) Steyerm and Palicourea coriacea (Cham.) K. Schum Leaves Analysed by Desorption Electrospray Ionisation Mass Spectrometry Imaging

    DEFF Research Database (Denmark)

    Kato, Lucilia; Moraes, Aline Pereira; de Oliveira, Cecília Maria Alves

    2018-01-01

    INTRODUCTION: Species of the genera Psychotria and Palicourea are sources of indole alkaloids, however, the distribution of alkaloids within the plants is not known. Analysing the spatial distribution using desorption electrospray ionisation mass spectrometry imaging (DESI-MSI) has become...... analyses. METHODOLOGY: Based upon previous structure elucidation studies, four alkaloids targeted in this study were identified using high resolution mass spectrometry by direct infusion of plant extracts, and their distributions were imaged by DESI-MSI via tissue imprints on a porous Teflon surface....... Relative quantitation of the four alkaloids was obtained by HPLC-MS/MS analysis performed using multiple-reaction monitoring (MRM) mode on a triple quadrupole mass spectrometer. RESULTS: Alkaloids showed distinct distributions on the leaf surfaces. Prunifoleine was mainly present in the midrib, while 10...

  13. Overexpression of Periostin and Lumican in Esophageal Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Kashyap, Manoj Kumar; Marimuthu, Arivusudar; Peri, Suraj; Kumar, Ghantasala S. Sameer; Jacob, Harrys K.C.; Prasad, Thottethodi Subrahmanya Keshava; Mahmood, Riaz; Kumar, K. V. Veerendra; Kumar, M. Vijaya; Meltzer, Stephen J.; Montgomery, Elizabeth A.; Kumar, Rekha V.; Pandey, Akhilesh

    2010-01-01

    To identify biomarkers for early detection for esophageal squamous cell carcinoma (ESCC), we previously carried out a genome-wide gene expression profiling study using an oligonucleotide microarray platform. This analysis led to identification of several transcripts that were significantly upregulated in ESCC compared to the adjacent normal epithelium. In the current study, we performed immunohistochemical analyses of protein products for two candidates genes identified from the DNA microarray analysis, periostin (POSTN) and lumican (LUM), using tissue microarrays. Increased expression of both periostin and lumican was observed in 100% of 137 different ESCC samples arrayed on tissue microarrays. Increased expression of periostin and lumican was observed in carcinoma as well as in stromal cell in the large majority of cases. These findings suggest that these candidates can be investigated in the sera of ESCC patients using ELISA or multiple reaction monitoring (MRM) type assays to further explore their utility as biomarkers

  14. LC-MS based Metabolomics

    DEFF Research Database (Denmark)

    Magdenoska, Olivera

    . The analytical tools applied for analysis of intracellular metabolites should be capable to cope with the large number of metabolites to be analyzed and the complex matrix in the samples. Therefore the combination of separation and detection techniques is commonly applied for analysis of intracellular........ In the studies conducted during this Ph.D. the developed method was used to understand how the genetic manipulations in various organisms, influence the levels of their intracellular metabolites. The method development was divided into three steps: i) optimization of the MS detection, ii) establishment...... of the MS detection aimed to determine multiple reaction monitoring (MRM) transitions of the analytes and to increase the sensitivity by testing different ion-source parameters and collision energies. This resulted in optimized detection of more than 50 intracellular metabolites. During the optimization...

  15. Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method.

    Science.gov (United States)

    Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A

    2012-11-01

    A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Development of QuEChERS-based extraction and liquid chromatography-tandem mass spectrometry method for quantifying flumethasone residues in beef muscle.

    Science.gov (United States)

    Park, Ki Hun; Choi, Jeong-Heui; Abd El-Aty, A M; Cho, Soon-Kil; Park, Jong-Hyouk; Kwon, Ki Sung; Park, Hee Ra; Kim, Hyung Soo; Shin, Ho-Chul; Kim, Mi Ra; Shim, Jae-Han

    2012-12-01

    A rapid, specific, and sensitive method based on liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM) was developed and validated to quantify flumethasone residues in beef muscle. Methods were compared between the original as well as the EN quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based extraction. Good linearity was achieved at concentration levels of 5-30 μg/kg. Estimated recovery rates at spiking levels of 5 and 10 μg/kg ranged from 72.1 to 84.6%, with relative standard deviations (RSDs)noise ratios (S/Ns) of 3 and 10, respectively. The method was successfully applied to analyze real samples obtained from large markets throughout the Korean Peninsula. The method proved to be sensitive and reliable and, thus, rendered an appropriate means for residue analysis studies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.

    Science.gov (United States)

    Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno

    2016-06-01

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Compact neutron flux monitor

    International Nuclear Information System (INIS)

    Madhavi, V.; Phatak, P.R.; Bahadur, C.; Bayala, A.K.; Jakati, R.K.; Sathian, V.

    2003-01-01

    Full text: A compact size neutron flux monitor has been developed incorporating standard boards developed for smart radiation monitors. The sensitivity of the monitors is 0.4cps/nV. It has been tested up to 2075 nV flux with standard neutron sources. It shows convincing results even in high flux areas like 6m away from the accelerator in RMC (Parel) for 106/107 nV. These monitors have a focal and remote display, alarm function with potential free contacts for centralized control and additional provision of connectivity via RS485/Ethernet. This paper describes the construction, working and results of the above flux monitor

  20. Nuclear reactor effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Minns, J.L.; Essig, T.H. [Nuclear Regulatory Commission, Washington, DC (United States)

    1993-12-31

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC`s program results.

  1. Nuclear reactor effluent monitoring

    International Nuclear Information System (INIS)

    Minns, J.L.; Essig, T.H.

    1993-01-01

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC's program results

  2. Movement monitoring device

    International Nuclear Information System (INIS)

    Ichikawa, Takashi; Yoneda, Yasuaki; Hanatsumi, Masaharu.

    1997-01-01

    The present invention provides a device suitable to accurate recognition for the moving state of reactor core fuels as an object to be monitored in a nuclear power plant. Namely, the device of the present invention prepares each of scheduled paths for the movement of the object to be monitored and executed moving paths along with the movement based on the information of the movement obtained from scheduled information for the movement of the reactor core fuels as a object to be monitored and the actual movement of the object to be monitored. The results of the preparation are outputted. As an output mode, (1) the results of preparation for each of the paths for movement and the results of the monitoring obtained by monitoring the state of the object to be monitored are jointed and outputted, (2) images showing each of the paths for the movement are formed, and the formed images are displayed on a screen, and (3) each of the moving paths is prepared as an image, and the image is displayed together with the image of the regions before and after the movement of the object to be monitored. In addition, obtained images of each of the paths for the movement and the monitored images obtained by monitoring the state of the object to be monitored are joined and displayed. (I.S.)

  3. Modular remote radiation monitor

    International Nuclear Information System (INIS)

    Lacerda, Fabio; Farias, Marcos S.; Aghina, Mauricio A.C.; Oliveira, Mauro V.

    2013-01-01

    The Modular Remote Radiation Monitor (MRRM) is a novel radiation monitor suitable for monitoring environmental exposure to ionizing radiation. It is a portable compact-size low-power microprocessor-based electronic device which provides its monitoring data to other electronic systems, physically distant from it, by means of an electronic communication channel, which can be wired or wireless according to the requirements of each application. Besides its low-power highly-integrated circuit design, the Modular Remote Radiation Monitor is presented in a modular architecture, which promotes full compliance to the technical requirements of different applications while minimizing cost, size and power consumption. Its communication capability also supports the implementation of a network of multiple radiation monitors connected to a supervisory system, capable of remotely controlling each monitor independently as well as visualizing the radiation levels from all monitors. A prototype of the MRRM, functionally equivalent to the MRA-7027 radiation monitor, was implemented and connected to a wired MODBUS network of MRA-7027 monitors, responsible for monitoring ionizing radiation inside Argonauta reactor room at Instituto de Engenharia Nuclear. Based on the highly positive experimental results obtained, further design is currently underway in order to produce a consumer version of the MRRM. (author)

  4. Environmental Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    Holland, R.C. [Science Applications International Corp., San Diego, CA (United States)

    1993-07-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. This revision to the Environmental Monitoring Plan was written to document the changes made to the Monitoring Program during 1992. Some of the data (most notably the statistical analyses of past monitoring data) has not been changed.

  5. Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Holland, R.C.

    1993-07-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. This revision to the Environmental Monitoring Plan was written to document the changes made to the Monitoring Program during 1992. Some of the data (most notably the statistical analyses of past monitoring data) has not been changed

  6. Determination of Organophosphorous Pesticides in Environmental Water Samples Using Surface-Engineered C18 Functionalized Silica-Coated Core-Shell Magnetic Nanoparticles-Based Extraction Coupled with GC-MS/MS Analysis.

    Science.gov (United States)

    Srivastava, Neha; Kumari, Supriya; Nair, Kishore; Alam, Samsul; Raza, Syed K

    2017-05-01

    The present paper depicts a novel method based on magnetic SPE (MSPE) for the determination of organophosphorus pesticides (OPs) such as phorate, malathion, and chlorpyrifos in environmental water samples. In this study, C18 functionalized silica-coated core-shell iron oxide magnetic nanoparticles (MNPs) were used as a surface-engineered magnetic sorbent for the selective extraction of pesticides from aqueous samples, followed by GC-MS and GC-tandem MS analysis for confirmative determination of the analytes. Various important method parameters, including quantity of MNP adsorbent, volume of sample, effective time for extraction, nature of the desorbing solvent, and pH of the aqueous sample, were investigated and optimized to obtain maximum method performance. Under the optimized instrumental analysis conditions, good linearity (r2 value ≥0.994) was achieved at the concentration range of 0.5-500 μg/L. Recoveries were in the range of 79.2-96.3 and 80.4-97.5% in selective-ion monitoring and multiple reaction monitoring (MRM) modes, respectively, at the spiking concentrations of 1, 5, and 10 μg/L. MRM mode showed better sensitivity, selectivity, and low-level detection (0.5 μg/L) of analytes. The novel MSPE method is a simple, cheap, rapid, and eco-friendly method for the determination of OPs in environmental water samples.

  7. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp.

    Science.gov (United States)

    Chen, Guoqiang; Hoptroff, Michael; Fei, Xiaoqing; Su, Ya; Janssen, Hans-Gerd

    2013-11-22

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal standard. Atmospheric pressure chemical ionization (APCI) in positive mode was applied for the detection of climbazole. For quantification, multiple reaction monitoring (MRM) transition 293.0>69.0 was monitored for climbazole, and MRM transition 296.0>225.1 for the deuterated climbazole. The linear range ran from 4 to 2000 ng mL(-1). The limit of detection (LOD) and the limit of quantification (LOQ) were 1 ng mL(-1) and 4 ng mL(-1), respectively, which enabled quantification of climbazole on artificial skin and human scalp at ppb level (corresponding to 16 ng cm(-2)). For the sampling of climbazole from human scalp the buffer scrub method using a surfactant-modified phosphate buffered saline (PBS) solution was selected based on a performance comparison of tape stripping, the buffer scrub method and solvent extraction in in vitro studies. Using this method, climbazole deposition in in vitro and in vivo studies was successfully quantified. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Widely-targeted quantitative lipidomics methodology by supercritical fluid chromatography coupled with fast-scanning triple quadrupole mass spectrometry.

    Science.gov (United States)

    Takeda, Hiroaki; Izumi, Yoshihiro; Takahashi, Masatomo; Paxton, Thanai; Tamura, Shohei; Koike, Tomonari; Yu, Ying; Kato, Noriko; Nagase, Katsutoshi; Shiomi, Masashi; Bamba, Takeshi

    2018-05-03

    Lipidomics, the mass spectrometry-based comprehensive analysis of lipids, has attracted attention as an analytical approach to provide novel insight into lipid metabolism and to search for biomarkers. However, an ideal method for both comprehensive and quantitative analysis of lipids has not been fully developed. Herein, we have proposed a practical methodology for widely-targeted quantitative lipidome analysis using supercritical fluid chromatography fast-scanning triple-quadrupole mass spectrometry (SFC/QqQMS) and theoretically calculated a comprehensive lipid multiple reaction monitoring (MRM) library. Lipid classes can be separated by SFC with a normal phase diethylamine-bonded silica column with high-resolution, high-throughput, and good repeatability. Structural isomers of phospholipids can be monitored by mass spectrometric separation with fatty acyl-based MRM transitions. SFC/QqQMS analysis with an internal standard-dilution method offers quantitative information for both lipid class and individual lipid molecular species in the same lipid class. Additionally, data acquired using this method has advantages including reduction of misidentification and acceleration of data analysis. Using the SFC/QqQMS system, alteration of plasma lipid levels in myocardial infarction-prone rabbits to the supplementation of eicosapentaenoic acid was first observed. Our developed SFC/QqQMS method represents a potentially useful tool for in-depth studies focused on complex lipid metabolism and biomarker discovery. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Tetrodotoxin Detection by a Surface Plasmon Resonance Sensor in Pufferfish Matrices and Urine

    Directory of Open Access Journals (Sweden)

    Allen D. Taylor

    2011-01-01

    Full Text Available Tetrodotoxin (TTX poisoning is most commonly associated with consumption of pufferfish. TTX is a low molecular weight (~319 Da neurotoxin that selectively blocks voltage-sensitive Na+-gated ion channels. The standard method accepted worldwide for monitoring TTX toxicity in food matrices is the mouse bioassay. Ethical concerns from live animal testing, low sample throughput, and analytical inaccuracies have led to the need for an alternative method. We have previously established that surface plasmon resonance (SPR sensors can quantify TTX in aqueous buffer samples by an antibody-based inhibition assay. In this paper, we report the extension of the assay for the detection of TTX in both clinical- and food-relevant matrices. The assay was optimized for application to three relevant complex matrices: pufferfish liver extract, pufferfish muscle extract, and human urine. Matrix effects are discussed and calibration curves are presented. Naturally contaminated pufferfish liver and muscle extracts were analyzed by the SPR method, and the data is compared to liquid-chromatography electrospray-ionization multiple reactions monitoring mass spectrometry (LC/ESI/MRM/MS data. Ten samples, including three from a poisoning incident, two control monkfish samples, and five toxic pufferfish samples, were analyzed using this method, and the data is compared to LC/ESI/MRM/MS analysis of the samples.

  10. Monitoring your baby before labor

    Science.gov (United States)

    ... stress test - monitoring; CST- monitoring; Biophysical profile - monitoring; BPP - monitoring ... A biophysical profile (BPP) is a NST with an ultrasound. If the NST results are not reactive, a BPP may be done. The ...

  11. Power consumption monitoring using additional monitoring device

    Energy Technology Data Exchange (ETDEWEB)

    Truşcă, M. R. C., E-mail: radu.trusca@itim-cj.ro; Albert, Ş., E-mail: radu.trusca@itim-cj.ro; Tudoran, C., E-mail: radu.trusca@itim-cj.ro; Soran, M. L., E-mail: radu.trusca@itim-cj.ro; Fărcaş, F., E-mail: radu.trusca@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Abrudean, M. [Technical University of Cluj-Napoca, Cluj-Napoca (Romania)

    2013-11-13

    Today, emphasis is placed on reducing power consumption. Computers are large consumers; therefore it is important to know the total consumption of computing systems. Since their optimal functioning requires quite strict environmental conditions, without much variation in temperature and humidity, reducing energy consumption cannot be made without monitoring environmental parameters. Thus, the present work uses a multifunctional electric meter UPT 210 for power consumption monitoring. Two applications were developed: software which carries meter readings provided by electronic and programming facilitates remote device and a device for temperature monitoring and control. Following temperature variations that occur both in the cooling system, as well as the ambient, can reduce energy consumption. For this purpose, some air conditioning units or some computers are stopped in different time slots. These intervals were set so that the economy is high, but the work's Datacenter is not disturbed.

  12. Monitor inspection device

    International Nuclear Information System (INIS)

    Ueshima, Yoshinobu.

    1995-01-01

    The device of the present invention reliably conducts monitoring by radiation monitors in a nuclear power plant thereby contributing to save the number of radiation operators and reduction of radiation exposure. Namely, radiation monitors continuously measure a plurality of γ-ray levels. A branched simultaneously counting circuit receives these signals. The output of the branched simultaneously counting circuit is inputted to a differentiation means. The differentiation means calculates a variation coefficient for each of the radiation monitoring values, namely, equivalent dose rates, and records and monitors change with time of the equivalent dose rates. With such procedures, the results of the monitoring of γ-ray levels can be judged objectively corresponding to the increase of the equivalent dose rates. As a result, the number of radiation operators can be saves and radiation exposure of the radiation operators can be reduced. (I.S.)

  13. Occupational monitoring program

    International Nuclear Information System (INIS)

    Sordi, G.-M.A.A.

    1988-10-01

    After to give the principal aim of a monitoring program it gives the philosophy in force in our country and the new one, international. It shows the different monitoring types and the classification related to their functions. The functions are deal with, separately, for workplace and individual monitoring. It shows, also, that the individual monitoring can be used to assess the workplace conditions. It discusses the models that can be introduced to assess the quantities used in the results interpretation from the quantities used in the measurements. It gives an example. Finally it discusses the supplementary functions of monitoring as such reassessment of monitoring programs, selection of the controlled areas and the extent form of medical supervision. (author) [pt

  14. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  15. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  16. Monitoring of radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-02-01

    The guide specifies the requirements for the monitoring of radiation exposure in instances where radiation is used. In addition to workers, the guide covers students, apprentices and visitors. The guide shall also apply to exposure from natural radiation. However, the monitoring of radiation exposure in nuclear power plants is dealt with in YVL Guide 7.10 and 7.11. The guide defines the concepts relevant to the monitoring of radiation exposure and provides guidelines for determining the necessity of monitoring and subsequently arranging such in different operations. In addition, the guide specifies the criteria for the approval and regulatory control of the dosimetric service.

  17. Monitoring of radiation exposure

    International Nuclear Information System (INIS)

    2000-02-01

    The guide specifies the requirements for the monitoring of radiation exposure in instances where radiation is used. In addition to workers, the guide covers students, apprentices and visitors. The guide shall also apply to exposure from natural radiation. However, the monitoring of radiation exposure in nuclear power plants is dealt with in YVL Guide 7.10 and 7.11. The guide defines the concepts relevant to the monitoring of radiation exposure and provides guidelines for determining the necessity of monitoring and subsequently arranging such in different operations. In addition, the guide specifies the criteria for the approval and regulatory control of the dosimetric service

  18. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  19. Environmental monitoring plan

    International Nuclear Information System (INIS)

    Holland, R.C.

    1997-02-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. 52 refs., 10 figs., 12 tabs

  20. Technical advances in proteomics: new developments in data-independent acquisition [version 1; referees: 3 approved

    Directory of Open Access Journals (Sweden)

    Alex Hu

    2016-03-01

    Full Text Available The ultimate aim of proteomics is to fully identify and quantify the entire complement of proteins and post-translational modifications in biological samples of interest. For the last 15 years, liquid chromatography-tandem mass spectrometry (LC-MS/MS in data-dependent acquisition (DDA mode has been the standard for proteomics when sampling breadth and discovery were the main objectives; multiple reaction monitoring (MRM LC-MS/MS has been the standard for targeted proteomics when precise quantification, reproducibility, and validation were the main objectives. Recently, improvements in mass spectrometer design and bioinformatics algorithms have resulted in the rediscovery and development of another sampling method: data-independent acquisition (DIA. DIA comprehensively and repeatedly samples every peptide in a protein digest, producing a complex set of mass spectra that is difficult to interpret without external spectral libraries. Currently, DIA approaches the identification breadth of DDA while achieving the reproducible quantification characteristic of MRM or its newest version, parallel reaction monitoring (PRM. In comparative de novo identification and quantification studies in human cell lysates, DIA identified up to 89% of the proteins detected in a comparable DDA experiment while providing reproducible quantification of over 85% of them. DIA analysis aided by spectral libraries derived from prior DIA experiments or auxiliary DDA data produces identification and quantification as reproducible and precise as that achieved by MRM/PRM, except on low‑abundance peptides that are obscured by stronger signals. DIA is still a work in progress toward the goal of sensitive, reproducible, and precise quantification without external spectral libraries. New software tools applied to DIA analysis have to deal with deconvolution of complex spectra as well as proper filtering of false positives and false negatives. However, the future outlook is

  1. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  2. Personnel Monitoring Department - DEMIN

    International Nuclear Information System (INIS)

    1989-01-01

    The activities and purposes of the Personnel Monitoring Dept. of the Institute of Radioprotection and Dosimetry of the Brazilian CNEN are presented. A summary of the personnel monitoring service is given, such as dosemeters supply, laboratorial inspections, and so on. The programs of working, publishing, courses and personnel interchange are also presented. (J.A.M.M.)

  3. Liquid metal monitor

    International Nuclear Information System (INIS)

    Caldwell-Nichols, C.J.; Roach, P.F.

    1982-01-01

    A liquid metal monitor of the by-pass plugging meter kind described in British Patent 1,308,466, is further provided with a pump arranged to oppose flow through a by-pass thereby to provide a constant pressure difference across an orifice and improve the sensitivity of the instrument. The monitor estimates the impurity content in a liquid metal stream. (author)

  4. Simple beam profile monitor

    Energy Technology Data Exchange (ETDEWEB)

    Gelbart, W.; Johnson, R. R.; Abeysekera, B. [ASD Inc. Garden Bay, BC (Canada); Best Theratronics Ltd Ottawa Ontario (Canada); PharmaSpect Ltd., Burnaby BC (Canada)

    2012-12-19

    An inexpensive beam profile monitor is based on the well proven rotating wire method. The monitor can display beam position and shape in real time for particle beams of most energies and beam currents up to 200{mu}A. Beam shape, position cross-section and other parameters are displayed on a computer screen.

  5. Improved Marine Waters Monitoring

    Science.gov (United States)

    Palazov, Atanas; Yakushev, Evgeniy; Milkova, Tanya; Slabakova, Violeta; Hristova, Ognyana

    2017-04-01

    IMAMO - Improved Marine Waters Monitoring is a project under the Programme BG02: Improved monitoring of marine waters, managed by Bulgarian Ministry of environment and waters and co-financed by the Financial Mechanism of the European Economic Area (EEA FM) 2009 - 2014. Project Beneficiary is the Institute of oceanology - Bulgarian Academy of Sciences with two partners: Norwegian Institute for Water Research and Bulgarian Black Sea Basin Directorate. The Project aims to improve the monitoring capacity and expertise of the organizations responsible for marine waters monitoring in Bulgaria to meet the requirements of EU and national legislation. The main outcomes are to fill the gaps in information from the Initial assessment of the marine environment and to collect data to assess the current ecological status of marine waters including information as a base for revision of ecological targets established by the monitoring programme prepared in 2014 under Art. 11 of MSFD. Project activities are targeted to ensure data for Descriptors 5, 8 and 9. IMAMO aims to increase the institutional capacity of the Bulgarian partners related to the monitoring and assessment of the Black Sea environment. The main outputs are: establishment of real time monitoring and set up of accredited laboratory facilities for marine waters and sediments chemical analysis to ensure the ability of Bulgarian partners to monitor progress of subsequent measures undertaken.

  6. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  7. Environmental radiation monitoring

    International Nuclear Information System (INIS)

    Watanabe, Isao

    2011-01-01

    The samples, pretreatment method, and measurement methods of 'Environmental radioactivity level by prefecture' of Ministry of Education, Culture, Sports, Science and Education (MEXT) is explained. It consists of 1), 'Environmental radioactivity level by prefecture' in normal period, 2) 'Strengthening of Monitoring of Environmental Radioactivity Level by Prefecture' of MEXT at emergency 3) strengthening of monitoring by Fukushima Daiichi nuclear accident, 4) radiation monitoring around the nuclear facility, 5) strengthening of monitoring by MEXT, and 6) quality of monitoring. The survey item and samples etc., of 'Environmental radioactivity level by prefecture', monitoring post, NaI (Tl) scintillation survey meter, sampling and pretreatment methods for radionuclide analysis in normal period, an example of germanium semiconductor detector, gamma ray spectrum of spaghetti from Italy by germanium semiconductor detector, flow chart of radionuclide analysis of fallout in normal period and emergency by germanium semiconductor detector, example of analytical method of radioactive strontium ( ion exchange method), outline of plutonium analytical method for emergency, sampling and pretreatment methods of radionuclides for strengthening, monitoring result around Fukushima Daiichi nuclear plant from June 23 to 24, 2011, change of air dose rate of monitoring post in Mito city from March 14 to 26, 2011, concentration of I-131 and Cs-137 in fallout in Hitachinaka city from March 19 to April 30, 2011, and change of concentration of I-131, Cs-134 and Cs-137 in tap water of Iitate village from March 20 to April 30, 2011, are illustrated. (S.Y.)

  8. Water Quality Monitoring Manual.

    Science.gov (United States)

    Mason, Fred J.; Houdart, Joseph F.

    This manual is designed for students involved in environmental education programs dealing with water pollution problems. By establishing a network of Environmental Monitoring Stations within the educational system, four steps toward the prevention, control, and abatement of water pollution are proposed. (1) Train students to recognize, monitor,…

  9. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  10. Monitoring Evolution at CERN

    CERN Document Server

    Andrade, P; Murphy, S; Pigueiras, L; Santos, M

    2015-01-01

    Over the past two years, the operation of the CERN Data Centres went through significant changes with the introduction of new mechanisms for hardware procurement, new services for cloud provisioning and configuration management, among other improvements. These changes resulted in an increase of resources being operated in a more dynamic environment. Today, the CERN Data Centres provide over 11000 multi-core processor servers, 130 PB disk servers, 100 PB tape robots, and 150 high performance tape drives. To cope with these developments, an evolution of the data centre monitoring tools was also required. This modernisation was based on a number of guiding rules: sustain the increase of resources, adapt to the new dynamic nature of the data centres, make monitoring data easier to share, give more flexibility to Service Managers on how they publish and consume monitoring metrics and logs, establish a common repository of monitoring data, optimise the handling of monitoring notifications, and replace the previous ...

  11. Monitoring production target thickness

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1993-01-01

    Pion and muon production targets at the Clinton P. Anderson Meson Physics Facility consist of rotating graphite wheels. The previous target thickness monitoring Procedure scanned the target across a reduced intensity beam to determine beam center. The fractional loss in current across the centered target gave a measure of target thickness. This procedure, however, required interruption of beam delivery to experiments and frequently indicated a different fractional loss than at normal beam currents. The new monitoring Procedure compares integrated ups and downs toroid current monitor readings. The current monitors are read once per minute and the integral of readings are logged once per eight-hour shift. Changes in the upstream to downstream fractional difference provide a nonintrusive continuous measurement of target thickness under nominal operational conditions. Target scans are now done only when new targets are installed or when unexplained changes in the current monitor data are observed

  12. Analysis of amino acids by HPLC/electrospray negative ion tandem mass spectrometry using 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) derivatization.

    Science.gov (United States)

    Ziegler, Jörg; Abel, Steffen

    2014-12-01

    A new method for the determination of amino acids is presented. It combines established methods for the derivatization of primary and secondary amino groups with 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) with the subsequent amino acid specific detection of the derivatives by LC-ESI-MS/MS using multiple reaction monitoring (MRM). The derivatization proceeds within 5 min, and the resulting amino acid derivatives can be rapidly purified from matrix by solid-phase extraction (SPE) on HR-X resin and separated by reversed-phase HPLC. The Fmoc derivatives yield several amino acid specific fragment ions which opened the possibility to select amino acid specific MRM transitions. The method was applied to all 20 proteinogenic amino acids, and the quantification was performed using L-norvaline as standard. A limit of detection as low as 1 fmol/µl with a linear range of up to 125 pmol/µl could be obtained. Intraday and interday precisions were lower than 10 % relative standard deviations for most of the amino acids. Quantification using L-norvaline as internal standard gave very similar results compared to the quantification using deuterated amino acid as internal standards. Using this protocol, it was possible to record the amino acid profiles of only a single root from Arabidopsis thaliana seedlings and to compare it with the amino acid profiles of 20 dissected root meristems (200 μm).

  13. Environmental effects on allergen levels in commercially grown non-genetically modified soybeans: assessing variation across North America

    Directory of Open Access Journals (Sweden)

    Severin E. Stevenson

    2012-08-01

    Full Text Available Soybean (Glycine max is a hugely valuable soft commodity that generates tens of billions of dollars annually. This value is due in part to the balanced composition of the seed which is roughly 1:2:2 oil, starch and protein by weight. In turn, the seeds have many uses with various derivatives appearing broadly in processed food products. As is true with many edible seeds, soybeans contain proteins that are anti-nutritional factors and allergens. Soybean, along with milk, eggs, fish, crustacean shellfish, tree nuts, peanuts and wheat, elicit a majority of food allergy reactions in the United States. Soybean seed composition can be affected by breeding, environmental conditions (e.g. temperature, moisture, insect/pathogen load, and/or soil nutrient levels. The objective of this study was to evaluate the influence of genotype and environment on allergen and anti-nutritional proteins in soybean. To address genetic and environmental effects, four varieties of non-GM soybeans were grown in six geographically distinct regions of North America (Georgia, Iowa, Kansas, Nebraska, Ontario, and Pennsylvania. Absolute quantification of proteins by mass spectrometry can be achieved with a technique called multiple reaction monitoring (MRM, during which signals from an endogenous protein are compared to those from a synthetic heavy-labeled internal standard. Using MRM, eight allergens were absolutely quantified for each variety in each environment. Statistical analyses show that for most allergens, the effects of environment far outweigh the differences between varieties brought about by breeding.

  14. Quantitating PrP Polymorphisms Present in Prions from Heterozygous Scrapie-Infected Sheep.

    Science.gov (United States)

    Silva, Christopher J; Erickson-Beltran, Melissa L; Hui, Colleen; Badiola, Juan José; Nicholson, Eric M; Requena, Jesús R; Bolea, Rosa

    2017-01-03

    Scrapie is a prion (PrP Sc ) disease of sheep. The incubation period of sheep scrapie is strongly influenced by polymorphisms at positions 136, 154, and 171 of a sheep's normal cellular prion protein (PrP C ). Chymotrypsin was used to digest sheep recombinant PrP to identify a set of characteristic peptides [M 132 LGSXMSRPL 141 (X = A or V), Y 153 XENMY 158 (X,= H or R), and Y 166 RPVDXY 172 (X = H, K, Q, or R)] that could be used to detect and quantitate polymorphisms at positions 136, 154, and 171 of sheep PrP C or PrP Sc . These peptides were used to develop a multiple reaction monitoring method (MRM) to detect the amounts of a particular polymorphism in a sample of PrP Sc isolated from sheep heterozygous for their PrP C proteins. The limit of detection for these peptides was less than 50 attomole. Spinal cord tissue from heterozygous (ARQ/VRQ or ARH/ARQ) scrapie-infected Rasa Aragonesa sheep was analyzed using this MRM method. Both sets of heterozygotes show the presence of both polymorphisms in PrP Sc . This was true for samples containing both proteinase K (PK)-sensitive and PK-resistant PrP Sc and samples containing only the PK-resistant PrP Sc . These results show that heterozygous animals contain PrP Sc that is composed of significant amounts of both PrP polymorphisms.

  15. Application of high-performance liquid chromatography-tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil.

    Science.gov (United States)

    Hernando, M D; Ferrer, C; Ulaszewska, M; García-Reyes, J F; Molina-Díaz, A; Fernández-Alba, A R

    2007-11-01

    This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of pesticides in olive oil. One hundred pesticides belonging to different classes and that are currently used in agriculture have been included in this method. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (QqQ(LIT)) analyzer. Key features of this technique are the rapid scan acquisition times, high specificity and high sensitivity it enables when the multiple reaction monitoring (MRM) mode or the linear ion-trap operational mode is employed. The application of 5 ms dwell times using a linearly accelerating (LINAC) high-pressure collision cell enabled the analysis of a high number of pesticides, with enough data points acquired for optimal peak definition in MRM operation mode and for satisfactory quantitative determinations to be made. The method quantifies over a linear dynamic range of LOQs (0.03-10 microg kg(-1)) up to 500 microg kg(-1). Matrix effects were evaluated by comparing the slopes of matrix-matched and solvent-based calibration curves. Weak suppression or enhancement of signals was observed (ion (EPI) and MS3 were developed.

  16. Age- and Activity-Related Differences in the Abundance of Myosin Essential and Regulatory Light Chains in Human Muscle

    Directory of Open Access Journals (Sweden)

    James N. Cobley

    2016-04-01

    Full Text Available Traditional methods for phenotyping skeletal muscle (e.g., immunohistochemistry are labor-intensive and ill-suited to multixplex analysis, i.e., assays must be performed in a series. Addressing these concerns represents a largely unmet research need but more comprehensive parallel analysis of myofibrillar proteins could advance knowledge regarding age- and activity-dependent changes in human muscle. We report a label-free, semi-automated and time efficient LC-MS proteomic workflow for phenotyping the myofibrillar proteome. Application of this workflow in old and young as well as trained and untrained human skeletal muscle yielded several novel observations that were subsequently verified by multiple reaction monitoring (MRM. We report novel data demonstrating that human ageing is associated with lesser myosin light chain 1 content and greater myosin light chain 3 content, consistent with an age-related reduction in type II muscle fibers. We also disambiguate conflicting data regarding myosin regulatory light chain, revealing that age-related changes in this protein more closely reflect physical activity status than ageing per se. This finding reinforces the need to control for physical activity levels when investigating the natural process of ageing. Taken together, our data confirm and extend knowledge regarding age- and activity-related phenotypes. In addition, the MRM transitions described here provide a methodological platform that can be fine-tuned to suite multiple research needs and thus advance myofibrillar phenotyping.

  17. Determination of pesticides and pesticide degradates in filtered water by direct aqueous-injection liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Kanagy, Leslie K.; Anderson, Cyrissa A.; Kanagy, Christopher J.

    2016-01-11

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for determination of 229 pesticides compounds (113 pesticides and 116 pesticide degradates) in filtered water samples from stream and groundwater sites. The pesticides represent a broad range of chemical classes and were selected based on criteria such as current-use intensity, probability of occurrence in streams and groundwater, and toxicity to humans or aquatic organisms. More than half of the analytes are pesticide degradates. The method involves direct injection of a 100-microliter (μL) sample onto the LC-MS/MS without any sample preparation other than filtration. Samples are analyzed with two injections, one in electrospray ionization (ESI) positive mode and one in ESI negative mode, using dynamic multiple reaction monitoring (MRM) conditions, with two MRM transitions for each analyte. The LC-MS/MS instrument parameters were optimized for highest sensitivity for the most analytes. This report describes the analytical method and presents characteristics of the method validation including bias and variability, detection levels, and holding-time studies.

  18. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  19. Integrative proteomics and tissue microarray profiling indicate the association between overexpressed serum proteins and non-small cell lung cancer.

    Directory of Open Access Journals (Sweden)

    Yansheng Liu

    Full Text Available Lung cancer is the leading cause of cancer deaths worldwide. Clinically, the treatment of non-small cell lung cancer (NSCLC can be improved by the early detection and risk screening among population. To meet this need, here we describe the application of extensive peptide level fractionation coupled with label free quantitative proteomics for the discovery of potential serum biomarkers for lung cancer, and the usage of Tissue microarray analysis (TMA and Multiple reaction monitoring (MRM assays for the following up validations in the verification phase. Using these state-of-art, currently available clinical proteomic approaches, in the discovery phase we confidently identified 647 serum proteins, and 101 proteins showed a statistically significant association with NSCLC in our 18 discovery samples. This serum proteomic dataset allowed us to discern the differential patterns and abnormal biological processes in the lung cancer blood. Of these proteins, Alpha-1B-glycoprotein (A1BG and Leucine-rich alpha-2-glycoprotein (LRG1, two plasma glycoproteins with previously unknown function were selected as examples for which TMA and MRM verification were performed in a large sample set consisting about 100 patients. We revealed that A1BG and LRG1 were overexpressed in both the blood level and tumor sections, which can be referred to separate lung cancer patients from healthy cases.

  20. Evaluation of Peripheral Blood and Cord Blood Platelet Lysates in Isolation and Expansion of Multipotent Mesenchymal Stromal Cells

    Directory of Open Access Journals (Sweden)

    Ioanna Christou

    2018-02-01

    Full Text Available Background: Multipotent Mesenchymal Stromal Cells (MSCs are used in tissue engineering and regenerative medicine. The in vitro isolation and expansion of MSCs involve the use of foetal bovine serum (FBS. However, many concerns have been raised regarding the safety of this product. In this study, alternative additives derived either from peripheral or cord blood were tested as an FBS replacement. Methods: Platelet lysates (PL from peripheral and cord blood were used for the expansion of MSCs. The levels of growth factors in peripheral blood (PB and cord blood (CB PLs were determined using the Multiple Reaction Monitoring (MRM. Finally, the cell doubling time (CDT, tri-lineage differentiation and phenotypic characterization of the MSCs expanded with FBS and PLs were determined. Results: MSCs treated with culture media containing FBS and PB-PL, were successfully isolated and expanded, whereas MSCs treated with CB-PL could not be maintained in culture. Furthermore, the MRM analysis yielded differences in growth factor levels between PB-PL and CB-PL. In addition, the MSCs were successfully expanded with FBS and PB-PL and exhibited tri-lineage differentiation and stable phenotypic characteristics. Conclusion: PB-PL could be used as an alternative additive for the production of MSCs culture medium applied to xenogeneic-free expansion and maintenance of MSCs in large scale clinical studies.

  1. Development of an Analytical Method for Analyzing Pyrrolizidine Alkaloids in Different Groups of Food by UPLC-MS/MS.

    Science.gov (United States)

    Chung, Stephen W C; Lam, Chi-Ho

    2018-03-21

    Suspected nontargeted pyrrolizidine alkaloids (PAs), without analytical reference standard, were observed and interfered with the determination of targeted PAs in complex food matrices, especially for spices samples. Selectivity and applicability of multiple reaction monitoring (MRM) transitions, multistage fragmentation (MS3), and MRM with differential ion mobility spectrometry (DMS) for eliminating false positive identifications were evaluated. Afterward, a selective and sensitive LC-MS/MS method for the determination of 15 PAs and 13 PA N-oxides in foodstuffs was developed. The sample preparation and cleanup are applicable to a wide range of foodstuffs, including cereal products, dairy products, meat, eggs, honey, tea infusion, and spices. Freezing-out of the raw extract and the water/acetonitrile washing steps in a solid phase extraction was found to efficiently remove complex matrices. The method was validated at 0.05 μg kg -1 for general food and 0.5 μg kg -1 for spices, with reference to the Eurachem Guide. The estimated limit of quantifications of different PAs was in the range of 0.010-0.087 μg kg -1 for general food and 0.04-0.76 μg kg -1 for spices. Isotopically labeled PAs were used as internal standards to correct the variation of PAs/PANs performance in different food commodities. Matrix effects observed in complex food matrices could be reduced by solvent dilution. Recoveries of PAs and PA N-oxides were all seen within 50-120%.

  2. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Tarkowski, Petr; Vaclavikova, Katerina; Novak, Ondrej; Pertry, Ine; Hanus, Jan; Whenham, Robert; Vereecke, Danny; Sebela, Marek; Strnad, Miroslav

    2010-01-01

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  3. Space weather monitoring with neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian [Christian-Albrechts-Universitaet zu Kiel (Germany)

    2013-07-01

    Space Weather affects many areas of the modern society, advance knowledge about space weather events is important to protect personnel and infrastructure. Cosmic Rays (CR) measurements by ground-based Neutron Monitors are influenced by Coronal Mass Ejections (CME), the intensity of the ever present Cosmic Rays is reduced in a Forbush decrease (Fd). In the case of very energetic CMEs, the measured intensity can be significantly increased in a Ground Level Enhancement (GLE). By detecting the anisotropy of the CR environment, a CME can be detected hours before it arrives at Earth. During a GLE the high-energy particles from the Sun can be detected before the more abundant lower energy particles arrive at Earth, thus allowing to take protective measures. Since the beginning of the Neutron Monitor Database (NMDB) project, which has been started in 2008 with funding from the European Commission, real-time data from Neutron Monitors around the world has been made available through one web-portal. We have more than doubled the number of stations providing data since the start of the project to now over 30 stations. The effectiveness of the ALERT applications which are based on NMDB data has been shown by the recent GLE71. We present different applications through which the measurements and different data products are accessible.

  4. CEMs turn monitoring giant

    International Nuclear Information System (INIS)

    White, J.R.

    1993-01-01

    Crucial to complying with environmental regulations is selecting appropriate pollution control equipment to capture or destroy regulated pollutants. But just as important is selecting a continuous emissions monitoring system (CEM). CEMs play a dual role in an overall compliance strategy. On one hand, they identify the type and quantity of emissions at a source as a first step for determining which regulatory requirements and control technologies are applicable. They also provide ongoing emissions data to demonstrate compliance with air and other environmental regulations. Facilities are required to monitor their processes with CEMs, or a comparable technology, under several titles of the Clean Air Act Amendments of 1990. CEMs meet regulatory requirements if they include a SO 2 concentration monitor, nitrogen oxides (NO x ) concentration monitor, volumetric flow monitor, opacity monitor, diluent gas monitor and data acquisition and handling system. The entire system and each subsystem has to be installed and certified before it can be used for compliance. A written quality assurance/quality control (QA/QC) plan for the CEMs must accompany the permit application. The acid rain rules also impose performance standards and frequent calibration checks to ensure the integrity of CEMs data

  5. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  6. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  7. Agile infrastructure monitoring

    International Nuclear Information System (INIS)

    Andrade, P; Ascenso, J; Fedorko, I; Fiorini, B; Paladin, M; Pigueiras, L; Santos, M

    2014-01-01

    At the present time, data centres are facing a massive rise in virtualisation and cloud computing. The Agile Infrastructure (AI) project is working to deliver new solutions to ease the management of CERN data centres. Part of the solution consists in a new 'shared monitoring architecture' which collects and manages monitoring data from all data centre resources. In this article, we present the building blocks of this new monitoring architecture, the different open source technologies selected for each architecture layer, and how we are building a community around this common effort.

  8. Radioactive Plumes Monitoring Simulator

    International Nuclear Information System (INIS)

    Kapelushnik, I.; Sheinfeld, M.; Avida, R.; Kadmon, Y.; Ellenbogen, M.; Tirosh, D.

    1999-01-01

    The Airborne Radiation Monitoring System (ARMS) monitors air or ground radioactive contamination. The contamination source can be a radioactive plume or an area contaminated with radionuclides. The system is based on two major parts, an airborne unit carried by a helicopter and a ground station carried by a truck. The system enables real time measurement and analysis of radioactive plumes as well as post flight processing. The Radioactive Plumes Monitoring Simulator purpose is to create a virtual space where the trained operators experience full radiation field conditions, without real radiation hazard. The ARMS is based on a flying platform and hence the simulator allows a significant reduction of flight time costs

  9. Java online monitoring framework

    International Nuclear Information System (INIS)

    Ronan, M.; Kirkby, D.; Johnson, A.S.; Groot, D. de

    1997-10-01

    An online monitoring framework has been written in the Java Language Environment to develop applications for monitoring special purpose detectors during commissioning of the PEP-II Interaction Region. PEP-II machine parameters and signals from several of the commissioning detectors are logged through VxWorks/EPICS and displayed by Java display applications. Remote clients are able to monitor the machine and detector performance using graphical displays and analysis histogram packages. In this paper, the design and implementation of the object-oriented Java framework is described. Illustrations of data acquisition, display and histograming applications are also given

  10. Plant monitoring system

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo.

    1994-01-01

    The memory means of the present invention memorize conditions for analyzing a sampling period for inputting process signals and time sequential data of the process signals. The process signals are analyzed following after sampling period and the analysis conditions stored in the memory means preceding to monitoring. A monitoring condition setting means controls and subsequently updates the sampling period and the analysis conditions in the memory means based on the analysis data, to finally set monitoring conditions. With such procedures, analysis conditions such as optimum analysis frequency range, signal sampling period and correlational characteristics between process noise signals are automatically selected. (I.S.)

  11. MCO Monitoring activity description

    International Nuclear Information System (INIS)

    SEXTON, R.A.

    1998-01-01

    Spent Nuclear Fuel remaining from Hanford's N-Reactor operations in the 1970s has been stored under water in the K-Reactor Basins. This fuel will be repackaged, dried and stored in a new facility in the 200E Area. The safety basis for this process of retrieval, drying, and interim storage of the spent fuel has been established. The monitoring of MCOS in dry storage is a currently identified issue in the SNF Project. This plan outlines the key elements of the proposed monitoring activity. Other fuel stored in the K-Reactor Basins, including SPR fuel, will have other monitoring considerations and is not addressed by this activity description

  12. Source Monitoring in Alzheimer's Disease

    Science.gov (United States)

    El Haj, Mohamad; Fasotti, Luciano; Allain, Philippe

    2012-01-01

    Source monitoring is the process of making judgments about the origin of memories. There are three categories of source monitoring: reality monitoring (discrimination between self- versus other-generated sources), external monitoring (discrimination between several external sources), and internal monitoring (discrimination between two types of…

  13. Monitoring Forsmark. Bird monitoring in Forsmark 2010

    Energy Technology Data Exchange (ETDEWEB)

    Green, Martin (Dept. of Animal Ecology, Lund Univ. (Sweden))

    2010-12-15

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds Directive) breeding birds in Forsmark 2002-2010. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2010 in the same way as in earlier years. The results from the monitoring in 2010 differed somewhat from results gathered in earlier years. Most monitored species have increased in local numbers during the study years, and from most years continued increases have been reported. Between 2009 and 2010 most species (seven, 64% of the monitored ones) instead decreased in numbers. Only one species (honey buzzard) increased in numbers between the years and in this case this was probably more a result of small moves by certain pairs so that they this year had parts reaching into the regional model area, while in 2009 their territories were outside of this. No dramatic changes in bird numbers were however recorded and all the studied species show stable or increasing local populations over the study period. Number of Black-throated diver pairs was normal and breeding success was good this year. The breeding success of divers has improved considerably over the studied period and the patterns recorded in Forsmark closely follow recorded patterns at the national level. Honey buzzards and ospreys occurred in good numbers, above the average for the whole period, and breeding success was better than in 2009. Even if breeding success of honey buzzards is not monitored in any detail, there were still signs of at least a few successful breedings in the area this year. Breeding success of ospreys was below average, but still within the normal variation for most years. The local white-tailed eagles had a poor breeding season and no young at all were produced within the study area. All three grouse species (black grouse, capercaillie and hazelhen) decreased in numbers between 2009 and 2010. Note however that the large amounts of snow

  14. Monitoring Forsmark. Bird monitoring in Forsmark 2010

    International Nuclear Information System (INIS)

    Green, Martin

    2010-12-01

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds Directive) breeding birds in Forsmark 2002-2010. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2010 in the same way as in earlier years. The results from the monitoring in 2010 differed somewhat from results gathered in earlier years. Most monitored species have increased in local numbers during the study years, and from most years continued increases have been reported. Between 2009 and 2010 most species (seven, 64% of the monitored ones) instead decreased in numbers. Only one species (honey buzzard) increased in numbers between the years and in this case this was probably more a result of small moves by certain pairs so that they this year had parts reaching into the regional model area, while in 2009 their territories were outside of this. No dramatic changes in bird numbers were however recorded and all the studied species show stable or increasing local populations over the study period. Number of Black-throated diver pairs was normal and breeding success was good this year. The breeding success of divers has improved considerably over the studied period and the patterns recorded in Forsmark closely follow recorded patterns at the national level. Honey buzzards and ospreys occurred in good numbers, above the average for the whole period, and breeding success was better than in 2009. Even if breeding success of honey buzzards is not monitored in any detail, there were still signs of at least a few successful breedings in the area this year. Breeding success of ospreys was below average, but still within the normal variation for most years. The local white-tailed eagles had a poor breeding season and no young at all were produced within the study area. All three grouse species (black grouse, capercaillie and hazelhen) decreased in numbers between 2009 and 2010. Note however that the large amounts of snow

  15. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  16. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  17. Ocean Disposal Site Monitoring

    Science.gov (United States)

    EPA is responsible for managing all designated ocean disposal sites. Surveys are conducted to identify appropriate locations for ocean disposal sites and to monitor the impacts of regulated dumping at the disposal sites.

  18. Reactor power monitoring device

    International Nuclear Information System (INIS)

    Kono, Shigehiro.

    1990-01-01

    Among a plurality of power monitoring programs in a reactor power monitoring device, rapid response is required for a scram judging program for the power judging processing of scram signals. Therefore, the scram judging program is stored independently from other power monitoring programs, applied with a priority order, and executed in parallel with other programs, to output scram signals when the detected data exceeds a predetermined value. As a result, the capacity required for the scram judging program is reduced and the processing can be conducted in a short period of time. In addition, since high priority is applied to the scram judging program which is divided into a small capacity, it is executed at higher frequency than other programs when they are executed in parallel. That is, since the entire processings for the power monitoring program are repeated in a short cycle, the response speed of the scram signals required for high responsivity can be increased. (N.H.)

  19. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  20. Nocturnal continuous glucose monitoring

    DEFF Research Database (Denmark)

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik

    2013-01-01

    Abstract Background: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe...

  1. ATLAS fast physics monitoring

    Indian Academy of Sciences (India)

    2012-11-16

    Nov 16, 2012 ... laboration has set up a framework to automatically process the ... ing (FPM) is complementary to data quality monitoring as problems may ... the full power of the ATLAS software framework Athena [4] and the availability of the.

  2. Lunar Health Monitor (LHM)

    Science.gov (United States)

    Lisy, Frederick J.

    2015-01-01

    Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

  3. Maine River Temperature Monitoring

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — We collect seasonal and annual temperature measurements on an hourly or quarter hourly basis to monitor habitat suitability for ATS and other species. Temperature...

  4. Equal Rights Monitor 2002

    NARCIS (Netherlands)

    Wil Portegijs; Annemarie Boelens; Saskia Keuzenkamp

    2002-01-01

    Original title: Emancipatiemonitor 2002. The Emancipation Monitor 2002 (Emancipatiemonitor 2002) provides statistics on the progress of the emancipation process, collected and analysed jointly by Statistics Netherlands (CBS) and the Netherlands Institute for Social Research/SCP. Is the

  5. Monitoring Microbially Influenced Corrosion

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    and diffusional effects and unreliable corrosion rates, when biofilm and ferrous sulphide corrosion products cover the steel surface. Corrosion rates can be overestimated by a factor of 10 to 100 by electrochemical techniques. Weight loss coupons and ER are recommended as necessary basic monitoring techniques......Abstract Microbially influenced corrosion (MIC) of carbon steel may occur in media with microbiological activity of especially sulphate-reducing bacteria (SRB). The applicability and reliability of a number of corrosion monitoring techniques for monitoring MIC has been evaluated in experiments....... EIS might be used for detection of MIC as the appearance of very large capacitances can be attributed to the combined ferrous sulphide and biofilm formation. Capacitance correlates directly with sulphide concentration in sterile sulphide media. Keywords: Corrosion monitoring, carbon steel, MIC, SRB...

  6. Phytoplankton Monitoring Network (PMN)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Phytoplankton Monitoring Network (PMN) is a part of the National Centers for Coastal Ocean Science (NCCOS). The PMN was created as an outreach program to connect...

  7. Use of remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fournel, E; Gouilloux, C

    1977-01-01

    Paper traces the development of remote monitoring devices, since their first appearance for safety purposes. Discusses their uses in coal mines: working and safety (definitions); sources and channels of information (transmission of information by automatic or verbal means); mine control stations; duties and responsibilities of persons in charge. Examines the contribution made by remote monitoring to management in production sector. Gives examples of assistance given to production management showing a very advantageous result on balance, by their use. The use of computers in real time and in batched mode is compared. Discusses their use in monitoring mine atmosphere. Very favorable results have already been obtained in France and abroad. The broadening scope and future of remote monitoring is considered.

  8. The Drought Monitor.

    Science.gov (United States)

    Svoboda, Mark; Lecomte, Doug; Hayes, Mike; Heim, Richard; Gleason, Karin; Angel, Jim; Rippey, Brad; Tinker, Rich; Palecki, Mike; Stooksbury, David; Miskus, David; Stephens, Scott

    2002-08-01

    information about drought and to receive regional and local input that is in turn incorporated into the product. This paper describes the Drought Monitor and the interactive process through which it is created.

  9. Optimization of environmental monitoring

    International Nuclear Information System (INIS)

    Winter, M.

    1986-01-01

    The routine work and tasks related to prevention in environmental monitoring of nuclear facilities range from low level methodology to the necessity of being likewise prepared to perform environmental impact measurements after nuclear incidents and accidents are presented [pt

  10. Infrastructure monitoring data management.

    Science.gov (United States)

    2015-07-01

    The primary objective of this project is to advance the development of a structural health monitoring : system (SHMS) for the Cut River Bridge. The scope includes performing an analysis from the fiber : optic strain gauge readings and making recommen...

  11. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  12. Heart failure - home monitoring

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000113.htm Heart failure - home monitoring To use the sharing features on ... your high blood pressure Fast food tips Heart failure - discharge Heart failure - fluids and diuretics Heart failure - what to ...

  13. Regional Seismic Threshold Monitoring

    National Research Council Canada - National Science Library

    Kvaerna, Tormod

    2006-01-01

    ... model to be used for predicting the travel times of regional phases. We have applied these attenuation relations to develop and assess a regional threshold monitoring scheme for selected subregions of the European Arctic...

  14. Environmental monitoring plan - environmental monitoring section. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Wilt, G.C. [ed.; Tate, P.J.; Brigdon, S.L. [and others

    1994-11-01

    This report presents the environmental monitoring plan for the Lawrence Livermore National Laboratory. A site characterization is provided along with monitoring and measurement techniques and quality assurance measures.

  15. Environmental monitoring plan - environmental monitoring section. Revision 1

    International Nuclear Information System (INIS)

    Wilt, G.C.; Tate, P.J.; Brigdon, S.L.

    1994-11-01

    This report presents the environmental monitoring plan for the Lawrence Livermore National Laboratory. A site characterization is provided along with monitoring and measurement techniques and quality assurance measures

  16. Reusable radiation monitor

    International Nuclear Information System (INIS)

    Fanselow, D.L.; Ersfeld, D.A.

    1978-01-01

    An integrating, reusable device for monitoring exposure to actinic radiation is disclosed. The device comprises a substrate having deposited thereon at least one photochromic aziridine compound which is sealed in an oxygen barrier to stabilize the color developed by the aziridine compound in response to actinic radiation. The device includes a spectral response shaping filter to transmit only actinic radiation of the type being monitored. A color standard is also provided with which to compare the color developed by the aziridine compound

  17. Monitoring of lightning discharge

    International Nuclear Information System (INIS)

    Grigor'ev, V.A.

    2001-01-01

    The paper presents a brief description of a lightning discharge recording system developed at the NPO 'Monitoring Techniques' under the direction of V.M. Moskolenko (Moscow). The system provides information about dangerous environmental occurrences such as tornados and hurricanes, making the forecast of extreme situations possible, especially in the areas of dangerous industries and objects. The created automatic system can be useful in solving the tasks relating to nuclear test monitoring. (author)

  18. Structure function monitor

    Science.gov (United States)

    McGraw, John T [Placitas, NM; Zimmer, Peter C [Albuquerque, NM; Ackermann, Mark R [Albuquerque, NM

    2012-01-24

    Methods and apparatus for a structure function monitor provide for generation of parameters characterizing a refractive medium. In an embodiment, a structure function monitor acquires images of a pupil plane and an image plane and, from these images, retrieves the phase over an aperture, unwraps the retrieved phase, and analyzes the unwrapped retrieved phase. In an embodiment, analysis yields atmospheric parameters measured at spatial scales from zero to the diameter of a telescope used to collect light from a source.

  19. Biosemiotics and ecological monitoring

    DEFF Research Database (Denmark)

    Bruni, Luis Emilio

    2001-01-01

    of the qualitative and relational aspects that can only be grasped by considering the semiotic networks operative in complex ecological and cultural systems. In this paper, it is suggested that a biosemiotic approach to ecology may prove useful for the modelling process, which in turn will allow the construction...... of meaningful monitoring systems. It is also contended that a biosemiotic approach may also serve to better integrate our understanding and monitoring of ecosystems into the cultural process of searching for (human) sustainability....

  20. Meteorological Monitoring Program

    International Nuclear Information System (INIS)

    Hancock, H.A. Jr.; Parker, M.J.; Addis, R.P.

    1994-01-01

    The purpose of this technical report is to provide a comprehensive, detailed overview of the meteorological monitoring program at the Savannah River Site (SRS) near Aiken, South Carolina. The principle function of the program is to provide current, accurate meteorological data as input for calculating the transport and diffusion of any unplanned release of an atmospheric pollutant. The report is recommended for meteorologists, technicians, or any personnel who require an in-depth understanding of the meteorological monitoring program

  1. Radioisotope dust pollution monitor

    International Nuclear Information System (INIS)

    Szepke, R.; Harasimczuk, J.; Dobrowiecki, J.

    1990-01-01

    Measuring principles and specification of two dust monitors: station-type AMIZ and portable-type PIK-10 for ambient air pollution are presented. The first one, a fully automatic instrument is destined for permanent monitoring of air pollution in preset sampling time from .25 to 24 hours. The second one was developed as a portable working model. Both instruments display their results in digital form in dust concentration units. (author)

  2. Monitor Sustainable Netherlands 2011

    International Nuclear Information System (INIS)

    2011-09-01

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [nl

  3. Monitor Sustainable Netherlands 2009

    International Nuclear Information System (INIS)

    2009-02-01

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk] [nl

  4. Advanced Environmental Monitoring Technologies

    Science.gov (United States)

    Jan, Darrell

    2004-01-01

    Viewgraphs on Advanced Environmental Monitoring Technologies are presented. The topics include: 1) Monitoring & Controlling the Environment; 2) Illustrative Example: Canary 3) Ground-based Commercial Technology; 4) High Capability & Low Mass/Power + Autonomy = Key to Future SpaceFlight; 5) Current Practice: in Flight; 6) Current Practice: Post Flight; 7) Miniature Mass Spectrometer for Planetary Exploration and Long Duration Human Flight; 8) Hardware and Data Acquisition System; 9) 16S rDNA Phylogenetic Tree; and 10) Preview of Porter.

  5. Robotic weed monitoring

    DEFF Research Database (Denmark)

    Bochtis, Dionysis; Sørensen, Claus Aage Grøn; Jørgensen, R N

    2011-01-01

    Abstract: In this paper, an integrated management system for the planning and activation of thefield monitoring task is presented. The architecture of the system is built around a mobile roboticunit. The internet based architecture of the system includes a station unit that works as a mobileon-fa...... of the weed monitoring operation.Key words: autonomous vehicles, farm management, mission planning, route planning,sampling....

  6. Meteorological Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, H.A. Jr. [ed.; Parker, M.J.; Addis, R.P.

    1994-09-01

    The purpose of this technical report is to provide a comprehensive, detailed overview of the meteorological monitoring program at the Savannah River Site (SRS) near Aiken, South Carolina. The principle function of the program is to provide current, accurate meteorological data as input for calculating the transport and diffusion of any unplanned release of an atmospheric pollutant. The report is recommended for meteorologists, technicians, or any personnel who require an in-depth understanding of the meteorological monitoring program.

  7. Quantitative measurement of a candidate serum biomarker peptide derived from α2-HS-glycoprotein, and a preliminary trial of multidimensional peptide analysis in females with pregnancy-induced hypertension.

    Science.gov (United States)

    Hamamura, Kensuke; Yanagida, Mitsuaki; Ishikawa, Hitoshi; Banzai, Michio; Yoshitake, Hiroshi; Nonaka, Daisuke; Tanaka, Kenji; Sakuraba, Mayumi; Miyakuni, Yasuka; Takamori, Kenji; Nojima, Michio; Yoshida, Koyo; Fujiwara, Hiroshi; Takeda, Satoru; Araki, Yoshihiko

    2018-03-01

    Purpose We previously attempted to develop quantitative enzyme-linked immunosorbent assay (ELISA) systems for the PDA039/044/071 peptides, potential serum disease biomarkers (DBMs) of pregnancy-induced hypertension (PIH), primarily identified by a peptidomic approach (BLOTCHIP®-mass spectrometry (MS)). However, our methodology did not extend to PDA071 (cysteinyl α2-HS-glycoprotein 341-367 ), due to difficulty to produce a specific antibody against the peptide. The aim of the present study was to establish an alternative PDA071 quantitation system using liquid chromatography-multiple reaction monitoring (LC-MRM)/MS, to explore the potential utility of PDA071 as a DBM for PIH. Methods We tested heat/acid denaturation methods in efforts to purify serum PDA071 and developed an LC-MRM/MS method allowing for specific quantitation thereof. We measured serum PDA071 concentrations, and these results were validated including by three-dimensional (3D) plotting against PDA039 (kininogen-1 439-456 )/044 (kininogen-1 438-456 ) concentrations, followed by discriminant analysis. Results PDA071 was successfully extracted from serum using a heat denaturation method. Optimum conditions for quantitation via LC-MRM/MS were developed; the assayed serum PDA071 correlated well with the BLOTCHIP® assay values. Although the PDA071 alone did not significantly differ between patients and controls, 3D plotting of PDA039/044/071 peptide concentrations and construction of a Jackknife classification matrix were satisfactory in terms of PIH diagnostic precision. Conclusions Combination analysis using both PDA071 and PDA039/044 concentrations allowed PIH diagnostic accuracy to be attained, and our method will be valuable in future pathophysiological studies of hypertensive disorders of pregnancy.

  8. Protocol for an electrospray ionization tandem mass spectral product ion library: development and application for identification of 240 pesticides in foods.

    Science.gov (United States)

    Zhang, Kai; Wong, Jon W; Yang, Paul; Hayward, Douglas G; Sakuma, Takeo; Zou, Yunyun; Schreiber, André; Borton, Christopher; Nguyen, Tung-Vi; Kaushik, Banerjee; Oulkar, Dasharath

    2012-07-03

    Modern determination techniques for pesticides must yield identification quickly with high confidence for timely enforcement of tolerances. A protocol for the collection of liquid chromatography (LC) electrospray ionization (ESI)-quadruple linear ion trap (Q-LIT) mass spectrometry (MS) library spectra was developed. Following the protocol, an enhanced product ion (EPI) library of 240 pesticides was developed by use of spectra collected from two laboratories. A LC-Q-LIT-MS workflow using scheduled multiple reaction monitoring (sMRM) survey scan, information-dependent acquisition (IDA) triggered collection of EPI spectra, and library search was developed and tested to identify the 240 target pesticides in one single LC-Q-LIT MS analysis. By use of LC retention time, one sMRM survey scan transition, and a library search, 75-87% of the 240 pesticides were identified in a single LC/MS analysis at fortified concentrations of 10 ng/g in 18 different foods. A conventional approach with LC-MS/MS using two MRM transitions produced the same identifications and comparable quantitative results with the same incurred foods as the LC-Q-LIT using EPI library search, finding 1.2-49 ng/g of either carbaryl, carbendazim, fenbuconazole, propiconazole, or pyridaben in peaches; carbendazim, imazalil, terbutryn, and thiabendazole in oranges; terbutryn in salmon; and azoxystrobin in ginseng. Incurred broccoli, cabbage, and kale were screened with the same EPI library using three LC-Q-LIT and a LC-quadruple time-of-flight (Q-TOF) instruments. The library search identified azoxystrobin, cyprodinil, fludioxinil, imidacloprid, metalaxyl, spinosyn A, D, and J, amd spirotetramat with each instrument. The approach has a broad application in LC-MS/MS type targeted screening in food analysis.

  9. Monitoring of radioactive wastes

    International Nuclear Information System (INIS)

    Houriet, J.Ph.

    1982-08-01

    The estimation of risks presented by final disposal of radioactive wastes depends, among other things, on what is known of their radioisotope content. The first aim of this report is to present the current state of possibilities for measuring (monitoring) radionuclides in wastes. The definition of a global monitoring system in the framework of radioactive waste disposal has to be realized, based on the information presented here, in accordance with the results of work to come and on the inventory of wastes to be stored. Designed for direct measurement of unpackaged wastes and for control of wastes ready to be stored, the system would ultimately make it possible to obtain all adaquate information about their radioisotope content with regard to the required disposal safety. The second aim of this report is to outline the definition of such a global system of monitoring. Designed as a workbase and reference source for future work by the National Cooperative for the Storage of Radioactive Waste on the topic of radioactive waste monitoring, this report describes the current situation in this field. It also makes it possible to draw some preliminary conclusions and to make several recommendations. Centered on the possibilities of current and developing techniques, it makes evident that a global monitoring system should be developed. However, it shows that the monitoring of packaged wastes will be difficult, and should be avoided as far as possible, except for control measurements

  10. Home apnea monitor use - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000755.htm Home apnea monitor use - infants To use the sharing ... portable. Why is an Apnea Monitor Used at Home? A monitor may be needed when: Your baby ...

  11. Battery Monitoring and Charging System

    National Research Council Canada - National Science Library

    Thivierge, Daniel P

    2007-01-01

    A battery monitoring device for a battery having cells grouped in modules. The device includes a monitoring circuit for each module which monitors the voltage in each cell and the overall module voltage...

  12. Photochemical Assessment Monitoring Stations (PAMS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Photochemical Assessment Monitoring Stations (PAMS). This file provides information on the numbers and distribution (latitude/longitude) of air monitoring sites...

  13. Monitoring Forsmark - Bird monitoring in Forsmark 2012

    Energy Technology Data Exchange (ETDEWEB)

    Green, Martin [Dept of Biology, Lund Univ., Lund (Sweden)

    2013-03-15

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds directive) breeding birds in Forsmark 2002 - 2012. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2012 in the same way as in earlier years. The results from 2012 generally follow patterns recorded in earlier years. 2012 was in general a better bird year compared to 2010 and 2011 and most species (82%) showed increasing or stable numbers from 2011 to 2012. Only two species (18%) decreased in numbers between the last two years. All in all, six species (55 %, black-throated diver, honey buzzard, black grouse, ural owl, wryneck and red-backed shrike) show no significant trends since the start of the bird monitoring (2002/2003/2004 depending on species). During this period three species (27 %, white-tailed eagle, osprey and lesser spotted woodpecker) have increased in numbers while just two (18 %, capercaillie and hazelhen) have decreased. A new pair of black-throated divers was discovered in 2012 and seven resident pairs were registered. Breeding success was very good, the second best during the study period. Population development follows the national pattern, but breeding success seems to be better in Forsmark than in the country as a whole. Honey buzzards and ospreys occurred in good numbers, and breeding success for ospreys was good. No signs of successful breedings of honey buzzards were recorded, but this may mean little as no detailed monitoring of breeding success is made for this species. The white-tailed eagles had their best breeding year since the start of the SKB bird monitoring, meaning that during the last two years local breeding success has been back at the level recorded before the site investigations started. The three grouse species (black grouse, capercaillie and hazelhen) again showed somewhat varying patterns between the last two years as well as in the long run. The black grouse increased

  14. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  15. Monitoring: The missing piece

    Energy Technology Data Exchange (ETDEWEB)

    Bjorkland, Ronald, E-mail: r_bjorkland@hotmail.com

    2013-11-15

    The U.S. National Environmental Policy Act (NEPA) of 1969 heralded in an era of more robust attention to environmental impacts resulting from larger scale federal projects. The number of other countries that have adopted NEPA's framework is evidence of the appeal of this type of environmental legislation. Mandates to review environmental impacts, identify alternatives, and provide mitigation plans before commencement of the project are at the heart of NEPA. Such project reviews have resulted in the development of a vast number of reports and large volumes of project-specific data that potentially can be used to better understand the components and processes of the natural environment and provide guidance for improved and efficient environmental protection. However, the environmental assessment (EA) or the more robust and intensive environmental impact statement (EIS) that are required for most major projects more frequently than not are developed to satisfy the procedural aspects of the NEPA legislation while they fail to provide the needed guidance for improved decision-making. While NEPA legislation recommends monitoring of project activities, this activity is not mandated, and in those situations where it has been incorporated, the monitoring showed that the EIS was inaccurate in direction and/or magnitude of the impact. Many reviews of NEPA have suggested that monitoring all project phases, from the design through the decommissioning, should be incorporated. Information gathered though a well-developed monitoring program can be managed in databases and benefit not only the specific project but would provide guidance how to better design and implement future activities designed to protect and enhance the natural environment. -- Highlights: • NEPA statutes created profound environmental protection legislative framework. • Contrary to intent, NEPA does not provide for definitive project monitoring. • Robust project monitoring is essential for enhanced

  16. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  17. Safe design and operation of tank reactors for multiple-reaction networks: uniqueness and multiplicity

    NARCIS (Netherlands)

    Westerterp, K.R.; Westerink, E.J.

    1990-01-01

    A method is developed to design a tank reactor in which a network of reactions is carried out. The network is a combination of parallel and consecutive reactions. The method ensures unique operation. Dimensionless groups are used which are either representative of properties of the reaction system

  18. Rare events via multiple reaction channels sampled by path replica exchange

    NARCIS (Netherlands)

    Bolhuis, P.G.

    2008-01-01

    Transition path sampling (TPS) was developed for studying activated processes in complex systems with unknown reaction coordinate. Transition interface sampling (TIS) allows efficient evaluation of the rate constants. However, when the transition can occur via more than one reaction channel

  19. Numerical estimates of multiple reaction corrections in neutron cross-section measurements

    International Nuclear Information System (INIS)

    Magnusson, G.

    1979-04-01

    A method to evaluate the effect of secondary neutrons in 14-15 MeV neutron cross-section measurements is presented. The emission spectra of secondary neutrons are calculated by means of the preequilibrium and statistical models. An expression for the collision probability in a homogenous body has been utilized in the calculations. (author)

  20. Investigation and application of multiple reactions between molybdoniobium heteropoly acid and di- or trimethylthionines

    Energy Technology Data Exchange (ETDEWEB)

    Mirzoyam, F.B.; Karapetyan, A.A.

    1986-03-01

    This paper presents the results of the study and use of reactions of molybdoniobic acid (MNA) with di- and trimethylthiones (DMT and TMT, respectively). It was found that light absorption of acetone solutions of the products of outer-sphere interaction between MNA and DMT or TMT enabled the determination of optimum acidity for MNA formation. Reaction between TMT and MNA gives two different compounds containing two and five associated dye cations, different in molar extinction coefficient and optimum reaction acidity (pH 0.05-0.25 and 0.35-0.90). Formation of the 6th and 8th molybdenum series with an identical composition of the outer sphere is shown. A highly sensitive photometric method for determining niobium has been developed.

  1. Structural characterization of tartrate dehydrogenase: a versatile enzyme catalyzing multiple reactions

    International Nuclear Information System (INIS)

    Malik, Radhika; Viola, Ronald E.

    2010-01-01

    The first structure of an NAD-dependent tartrate dehydrogenase (TDH) has been solved to 2 (angstrom) resolution by single anomalous diffraction (SAD) phasing as a complex with the intermediate analog oxalate, Mg 2+ and NADH. This TDH structure from Pseudomonas putida has a similar overall fold and domain organization to other structurally characterized members of the hydroxy-acid dehydrogenase family. However, there are considerable differences between TDH and these functionally related enzymes in the regions connecting the core secondary structure and in the relative positioning of important loops and helices. The active site in these complexes is highly ordered, allowing the identification of the substrate-binding and cofactor-binding groups and the ligands to the metal ions. Residues from the adjacent subunit are involved in both the substrate and divalent metal ion binding sites, establishing a dimer as the functional unit and providing structural support for an alternating-site reaction mechanism. The divalent metal ion plays a prominent role in substrate binding and orientation, together with several active-site arginines. Functional groups from both subunits form the cofactor-binding site and the ammonium ion aids in the orientation of the nicotinamide ring of the cofactor. A lysyl amino group (Lys192) is the base responsible for the water-mediated proton abstraction from the C2 hydroxyl group of the substrate that begins the catalytic reaction, followed by hydride transfer to NAD. A tyrosyl hydroxyl group (Tyr141) functions as a general acid to protonate the enolate intermediate. Each substrate undergoes the initial hydride transfer, but differences in substrate orientation are proposed to account for the different reactions catalyzed by TDH.

  2. Overview of food monitors

    International Nuclear Information System (INIS)

    Saito, I.

    2014-01-01

    May 11th 2011, nuclear accidents occurred by Tohoku Region Pacific Coast Earthquake made radioisotopes overflow in reactors and spread around the environments, and it caused risk of food contamination in these areas. And May 17th 2011, Ministry of Health, Labour and Welfare Japan announced provisional regulation values of radioactive materials in food in accordance with the food sanitation act. And they had notified the municipality to corresponding foods above the provisional regulation not had to be on sale. It causes massive needs for food monitoring in Japan. For reply to these massive needs, Hitachi Aloka Medical Ltd. commercialized food monitor: CAN-OSP-NAI in cooperation with CANBERRA Industries Inc. And after this, commercialized food screening system: FSS-101 for reply more expand food monitoring in Japan. This paper introduce Hitachi Aloka Medical Ltd. products which two types of food monitor product, provisional regulation values of radioactive materials in food in accordance with the food sanitation act and with comparing with past food monitoring, needs when accident happen. I wish this is going to be good report for help to radioactive and radiation detection in the future. (author)

  3. Radioactivity monitoring in Romania

    International Nuclear Information System (INIS)

    Alexandrescu, M.; Milu, C.

    1996-01-01

    Radioactivity monitoring in Romania is based on National Regulations for Radiation Protection enforced in 1976, on other environment protection laws enforced in the last years and on the recommendations of IAEA. Accordingly two systems of radioactive monitoring are to date operational in this field: the first one is the self-control of the radioactive emissions in the environment generated by the own nuclear activities (of nuclear units like the Cernavoda NPP, the Institute of Atomic Physics at Magurele-Bucharest, the Institute for Nuclear Research at Pitesti, the R Plant at Feldioara, Uranium mining units, etc.), while the other is based on two national agencies (the National Network of Environment Radiation Monitoring of the Ministry of Waters, Forests and Environment Protection and the Network of Radiation Hygiene Laboratories of the Health Ministry). The authors review and discuss the radiation protection legislation, the structure and the organizational operations of the national monitoring systems and the co-operation of the national monitoring systems with international authorities or programmes. 3 Figs., 1 tab., 11 refs

  4. Serial Network Flow Monitor

    Science.gov (United States)

    Robinson, Julie A.; Tate-Brown, Judy M.

    2009-01-01

    Using a commercial software CD and minimal up-mass, SNFM monitors the Payload local area network (LAN) to analyze and troubleshoot LAN data traffic. Validating LAN traffic models may allow for faster and more reliable computer networks to sustain systems and science on future space missions. Research Summary: This experiment studies the function of the computer network onboard the ISS. On-orbit packet statistics are captured and used to validate ground based medium rate data link models and enhance the way that the local area network (LAN) is monitored. This information will allow monitoring and improvement in the data transfer capabilities of on-orbit computer networks. The Serial Network Flow Monitor (SNFM) experiment attempts to characterize the network equivalent of traffic jams on board ISS. The SNFM team is able to specifically target historical problem areas including the SAMS (Space Acceleration Measurement System) communication issues, data transmissions from the ISS to the ground teams, and multiple users on the network at the same time. By looking at how various users interact with each other on the network, conflicts can be identified and work can begin on solutions. SNFM is comprised of a commercial off the shelf software package that monitors packet traffic through the payload Ethernet LANs (local area networks) on board ISS.

  5. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  6. Wide area monitoring study

    International Nuclear Information System (INIS)

    Wogman, N.A.; Holdren, G.R. Jr.

    1999-01-01

    Environmental sampling can be used to complement the safeguarding of nuclear material, especially in the detection of undeclared nuclear activities. Routine monitoring of nuclear installations has provided valuable information about the fate of key signature materials within different environmental settings. The approach collates information regarding the generation of individual radiochemical signatures within different nuclear processes, the potential for release of these signatures to the environment and, the chemical form and mobility of the signatures in environmental media along which the material could migrate. Meteorological, geological and hydrological information is used to determine where to sample, what to sample, and how often to sample to provide the greatest likelihood for detection. Multiple strategies can be used to implement wide area monitoring for safeguards purposes. The most complex, and expensive of these, involves establishing extensive networks of fixed location sampling sites. The sites would be operated continuously, and would be instrumented with automated sampling, analysis, and communication equipment to relay information regarding potential anomalies to control centers in near-real time. Alternative strategies can be used to supplement fixed location monitoring equipment, especially in regions that cannot support (financially or logistically) the fixed stations. Through combinations of these various strategies, using a variety of environmental media to monitor a region, we believe that a competent network, one with a quantifiable probability for detecting undeclared nuclear activities, can be designed. While this approach cannot and should not replace other inspection and monitoring activities, it can potentially contribute valuable information to an international safeguards system. (author)

  7. Radiation monitoring device

    International Nuclear Information System (INIS)

    Sato, Toshifumi.

    1993-01-01

    The device of the present invention concerns a reactor start-up region monitor of a nuclear power plant. In an existent start-up region monitor, bias voltage is limited, if the reactor moves to a power region, in order to prevent degradation of radiation detectors. Accordingly, since the power is lower than an actual reactor power, the reactor power can not be monitored. The device of the present invention comprises a memory means for previously storing a Plateau's characteristic of the radiation detectors and a correction processing means for obtaining a correction coefficient in accordance with the Plateau's characteristic to correct and calculate the reactor power when the bias voltage is limited. With such a constitution, when the reactor power exceeds a predetermined value and the bias voltage is limited, the correction coefficient can be obtained by the memory means and the correction processing means. Corrected reactor power can also be obtained from the start-up region monitor by the correction coefficient. As a result, monitoring of the reactor power can be continued while preventing degradation of the radiation detector even if the bias voltage is limited. (I.S.)

  8. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  9. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  10. Environmental monitoring programme

    International Nuclear Information System (INIS)

    1991-08-01

    During 1989 there were about 1000 premises in England and Wales authorised to discharge radioactive wastes. The majority of these premises consisted of hospitals, universities and industrial, research or manufacturing centres. Discharges from these premises when made in accordance with the strict conditions specified in their authorisations will have been of little radiological significance. In the case of nuclear sites authorisations or approvals are issued jointly by the DoE and the Ministry of Agriculture, Fisheries and Food (MAFF) known collectively as the Authorising Departments. In Wales these functions are undertaken by the Welsh Office with the support of HMIP and MAFF. The Authorising Departments specify numerical limits on the amounts of radioactivity which operators may discharge to the environment. In addition operators are required to demonstrate that the best practicable means (BPM) to minimise discharges is undertaken. Operators are also required to carry out appropriate environmental monitoring to demonstrate the effectiveness of BPM. As part of their regulatory functions the Authorising Departments undertake their own environmental monitoring programmes to act as both a check on site operator's returns and to provide independent data on the exposure of the public. HM Inspectorate of Pollution has monitored levels of radioactivity in drinking water sources for many years and published results annually. MAFF undertakes two programmes to monitor radioactivity in the aquatic environment and in terrestrial foodstuffs and publishes annual reports. Environmental monitoring programmes undertaken by both nuclear site operators and government departments are summarised. (author)

  11. Augmented fish health monitoring

    International Nuclear Information System (INIS)

    Michak, P.; Rogers, R.; Amos, K.

    1991-05-01

    The Bonneville Power Administration (BPA) initiated the Augmented Fish Health Monitoring project in 1986. This project was a five year interagency project involving fish rearing agencies in the Columbia Basin. Historically, all agencies involved with fish health in the Columbia Basin were conducting various levels of fish health monitoring, pathogen screening and collection. The goals of this project were; to identify, develop and implement a standardized level of fish health methodologies, develop a common data collection and reporting format in the area of artificial production, evaluate and monitor water quality, improve communications between agencies and provide annual evaluation of fish health information for production of healthier smolts. This completion report will contain a project evaluation, review of the goals of the project, evaluation of the specific fish health analyses, an overview of highlights of the project and concluding remarks. 8 refs., 1 fig., 4 tabs

  12. CMS Space Monitoring

    Science.gov (United States)

    Ratnikova, N.; Huang, C.-H.; Sanchez-Hernandez, A.; Wildish, T.; Zhang, X.

    2014-06-01

    During the first LHC run, CMS stored about one hundred petabytes of data. Storage accounting and monitoring help to meet the challenges of storage management, such as efficient space utilization, fair share between users and groups and resource planning. We present a newly developed CMS space monitoring system based on the storage metadata dumps produced at the sites. The information extracted from the storage dumps is aggregated and uploaded to a central database. A web based data service is provided to retrieve the information for a given time interval and a range of sites, so it can be further aggregated and presented in the desired format. The system has been designed based on the analysis of CMS monitoring requirements and experiences of the other LHC experiments. In this paper, we demonstrate how the existing software components of the CMS data placement system, PhEDEx, have been re-used, dramatically reducing the development effort.

  13. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  14. Neutron flux monitoring device

    International Nuclear Information System (INIS)

    Goto, Yasushi; Mitsubori, Minehisa; Ohashi, Kazunori.

    1997-01-01

    The present invention provides a neutron flux monitoring device for preventing occurrence of erroneous reactor scram caused by the elevation of the indication of a start region monitor (SRM) due to a factor different from actual increase of neutron fluxes. Namely, judgement based on measured values obtained by a pulse counting method and a judgment based on measured values obtained by a Cambel method are combined. A logic of switching neutron flux measuring method to be used for monitoring, namely, switching to an intermediate region when both of the judgements are valid is adopted. Then, even if the indication value is elevated based on the Cambel method with no increase of the counter rate in a neutron source region, the switching to the intermediate region is not conducted. As a result, erroneous reactor scram such as 'shorter reactor period' can be avoided. (I.S.)

  15. CMS Space Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ratnikova, N. [Fermilab; Huang, C.-H. [Fermilab; Sanchez-Hernandez, A. [CINVESTAV, IPN; Wildish, T. [Princeton U.; Zhang, X. [Beijing, Inst. High Energy Phys.

    2014-01-01

    During the first LHC run, CMS stored about one hundred petabytes of data. Storage accounting and monitoring help to meet the challenges of storage management, such as efficient space utilization, fair share between users and groups and resource planning. We present a newly developed CMS space monitoring system based on the storage metadata dumps produced at the sites. The information extracted from the storage dumps is aggregated and uploaded to a central database. A web based data service is provided to retrieve the information for a given time interval and a range of sites, so it can be further aggregated and presented in the desired format. The system has been designed based on the analysis of CMS monitoring requirements and experiences of the other LHC experiments. In this paper, we demonstrate how the existing software components of the CMS data placement system, PhEDEx, have been re-used, dramatically reducing the development effort.

  16. Monitoring with Data Automata

    Science.gov (United States)

    Havelund, Klaus

    2014-01-01

    We present a form of automaton, referred to as data automata, suited for monitoring sequences of data-carrying events, for example emitted by an executing software system. This form of automata allows states to be parameterized with data, forming named records, which are stored in an efficiently indexed data structure, a form of database. This very explicit approach differs from other automaton-based monitoring approaches. Data automata are also characterized by allowing transition conditions to refer to other parameterized states, and by allowing transitions sequences. The presented automaton concept is inspired by rule-based systems, especially the Rete algorithm, which is one of the well-established algorithms for executing rule-based systems. We present an optimized external DSL for data automata, as well as a comparable unoptimized internal DSL (API) in the Scala programming language, in order to compare the two solutions. An evaluation compares these two solutions to several other monitoring systems.

  17. Part 6: Forest monitoring

    International Nuclear Information System (INIS)

    1997-01-01

    In this part the results of forest monitoring on Hungarian and Slovak territory are presented. The two countries examine the growth and the health conditions of trees in similar ways. The monitoring sites in the Slovak and Hungarian territories, included in the joint monitoring, are shown on figure. The Slovak Party has already evaluated the wood yield data for 1996, the weekly girth growth observations in 1996 were not performed yet. So far on the Hungarian side only the weekly girth growth data are available for the year 1996, the wood yield data for 1996 are being processed. In the evaluation of Hungarian side only the results obtained for the period from 1992 to 1995 were analysed. Moreover, on the Slovak side an evaluation of the health conditions of trees based on aerial was carried out. The Hungarian party did not carried out such a survey, therefore the evaluation is based only on field (on-the-spot) observations

  18. Reactor power distribution monitor

    International Nuclear Information System (INIS)

    Hoizumi, Atsushi.

    1986-01-01

    Purpose: To grasp the margin for the limit value of the power distribution peaking factor inside the reactor under operation by using the reactor power distribution monitor. Constitution: The monitor is composed of the 'constant' file, (to store in-reactor power distributions obtained from analysis), TIP and thermocouple, lateral output distribution calibrating apparatus, axial output distribution synthesizer and peaking factor synthesizer. The lateral output distribution calibrating apparatus is used to make calibration by comparing the power distribution obtained from the thermocouples to the power distribution obtained from the TIP, and then to provide the power distribution lateral peaking factors. The axial output distribution synthesizer provides the power distribution axial peaking factors in accordance with the signals from the out-pile neutron flux detector. These axial and lateral power peaking factors are synthesized with high precision in the three-dimensional format and can be monitored at any time. (Kamimura, M.)

  19. MCO Monitoring Plan

    International Nuclear Information System (INIS)

    SEXTON, R.A.

    2000-01-01

    The basis for development of the Multi-Canister Overpack (MCO) Monitoring Plan was established in HNF-3312, MCO Monitoring Activity Description (Sexton 1998), with the following specific objectives: The safety of Spent Nuclear Fuel (SNF) Project processes for retrieving, packaging, handling, conditioning, and storing the N Reactor spent nuclear fuel has been demonstrated by conservative analyses, as compiled in the project safety basis and licensing documentation. Appropriate quality assurance and independent checking of engineering, fabrication, and construction are being applied, and there will be in-process monitoring and verification of MCO loading and conditioning actions. Once the MCOs have been placed in storage, there is no safety requirement, regulatory requirement, or precedent to monitor them. Although not required, a monitoring program which would acquire data for use by Process Engineering is considered valuable for several reasons (Sexton 1998): Good engineering practice--Acquiring data at a reasonable cost that may be useful in developing a fuller understanding of the behavior of an engineered system is good engineering practice. Actual data on full scale MCOs is otherwise unavailable--Previous investigations have been limited to small fuel samples or simulant prototypes and have been relatively short in duration. MCO monitoring can provide data on large loads of actual fuel, in full-scale configuration, over longer time periods. Additional knowledge of the fuel type may prove valuable in future analyses or applications. On that basis, a program with two components was planned: The pressure/temperature/gas composition relationships will be observed in a limited number of MCOs during the first two years in storage. The remaining MCOs will incorporate a simple means to confirm at any time in the future, that internal pressure of the MCO is not high enough to threaten its structural integrity. The MCOs are likely to be stored for 40 years or longer

  20. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  1. CLIC Luminosity Monitoring

    CERN Document Server

    Apyan, Armen; Gschwendtner, Edda; Lefevre, Thibault; Tygier, Sam; Appleby, Robert B

    2012-01-01

    The CLIC post-collision line is designed to transport the un-collided beams and the products of the collided beams with a total power of 14 MW to the main beam dump. Luminosity monitoring for CLIC is based on high energy muons produced by beamstrahlung photons in the main dump. Threshold Cherenkov counters are proposed for the detection of these muons. The expected rates and layout for these detectors is presented. Another method for luminosity monitoring is to directly detect the beamstrahlung photons in the post-collision line. Full Monte Carlo simulation has been performed to address its feasibility.

  2. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  3. Monitors for TJII

    International Nuclear Information System (INIS)

    Tafalla, D.; Tabares, F.L.; Ortiz, P.; Lopez-Sanchez, A.; Martin Fresno, L.M.; Sanchez Sarabia, E.; Encabo, J.

    1998-06-01

    A set of monitors for the measurement of Hα radiation (656.3 nm) have been installed in TJ-II stellarator. The detectors are placed directly on the windows of the chamber and they are built using Si photodiodes and interference filters with a compact design that make easy their handling and maintenance. Here we describe the mechanical and electrical design of the monitors, their position in TJ-II and some examples of their working during the first discharges of the machine. (Author) 3 refs

  4. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  5. Routine sanitary radiation monitoring

    International Nuclear Information System (INIS)

    Marej, A.N.

    1984-01-01

    Hygienic bases and organization principles of radiation monitoring realized in the process of operation of nuclear power engineering enterprises are considered. The monitoring is aimed at prevention from a negative effect of ionizing radiations on public heath. It is achieved by solution of the following tasks: realization of control over radioactive waste disposal into environment, control over the level of radioactive substance content in evironmental objects, control over external and internal irradiation of population assessment of environmental radiactivity of certain regions and of the territory of the country with the subsequent informing the corresponding organizations and population

  6. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  7. Environmental monitoring of nuclear facilities

    International Nuclear Information System (INIS)

    Koelzer, W.

    1988-01-01

    Environmental monitoring of nuclear facilities is part of general monitoring for environmental radioactivity all over the territory of the Federal Republic of Germany. General principles of environmental monitoring were formulated by the ICRP in 1965. In 1974 guidelines for measures of monitoring the environment of NPP incorporating LWR were drafted, which helped to standardize environmental monitoring programs. Since 1958, data on environmental radioactivity from measurements by authorized laboratories have been published in reports. (DG)

  8. Radiation monitoring around accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Shinichi [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan)

    2000-07-01

    The present status of a network of radiation monitors (NORM) working at KEK is described in detail. NORM consists of there parts; stand-alone radiation monitors (SARM), local-monitoring stations (STATION) and a central data-handling system (CENTER). NORM has developed to a large-scaled monitoring system in which more than 250 SARMs are under operation for monitoring the radiation fields and radioactivities around accelerators in KEK. (author)

  9. Monitor veiligheid en vertrouwen

    NARCIS (Netherlands)

    Degen, A.J.G.; Huveneers, S.G.; Kooij, R.E.

    2012-01-01

    Doelstelling: Om meer inzicht te krijgen in de risico’s bij het gebruik van ICT-diensten en de relatie met het vertrouwen van consumenten en bedrijven, is besloten te werken aan een monitor ‘Vertrouwen in ICT’. Dit onderzoek heeft als doel de eerste noodzakelijke stap te zetten: het bouwen van een

  10. Icinga Monitoring System Interface

    CERN Document Server

    Neculae, Alina Georgiana

    2014-01-01

    The aim of this project is to develop a web interface that would be used by the Icinga monitoring system to manage the CMS online cluster, in the experimental site. The interface would allow users to visualize the information in a compressed and intuitive way, as well as modify the information of each individual object and edit the relationships between classes.

  11. Intracranial Pressure Monitoring

    DEFF Research Database (Denmark)

    Raboel, P H; Bartek, J; Andresen, M

    2012-01-01

    Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods...

  12. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  13. The ozone monitoring instrument

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.R.; Mälkki, A.; Visser, H.; Vries, J. de; Stammes, P.; Lundell, J.O.V.; Saari, H.

    2006-01-01

    The Ozone Monitoring Instrument (OMI) flies on the National Aeronautics and Space Adminsitration's Earth Observing System Aura satellite launched in July 2004. OMI is a ultraviolet/visible (UV/VIS) nadir solar backscatter spectrometer, which provides nearly global coverage in one day with a spatial

  14. Ballast Water Self Monitoring

    Science.gov (United States)

    2011-11-01

    Hydrogen peroxide  Menadione /Vitamin K The efficacy of these processes varies by water conditions such as pH, temperature and, most significantly...Hydrocyclone power consumption, voltage and current Hydrocyclone power consumption, voltage and current Menadione /Vitamin K Menadione Chemical analysis...and treatment monitoring - Menadione /Vitamin K concentration at injection - Menadione /Vitamin K dosage and usage - Menadione /Vitamin K

  15. CODAS object monitoring service

    International Nuclear Information System (INIS)

    Wheatley, M.R.; Rainford, M.

    2001-01-01

    The primary Control and Data Acquisition System (CODAS) of JET is based on a TCP/IP network of more than 150 computers. The CODAS computers provide the JET machine control and data acquisition for over 70,000 digital and analog signals. The Object Monitoring Service (OMS) is used by applications for monitoring objects for presentation to the JET machine operators and for the operation of individual software components (such as valve state, access control, mimic definition changes and internal data distribution). Each server typically handles connections from around 60 clients monitoring upwards of 2000 objects. Some servers have over 150 clients and 5000 objects. Acquisition libraries are dynamically linked into a running server as required either to acquire data values for objects or to forward requests to other OMS servers. A mechanism involving dynamic linking allows new libraries to be integrated without stopping or changing running software. OMS provides a very reliable and highly successful 'data-type independent' means of monitoring many different objects. It allows applications to take advantage of new data sources, without the need to change existing code

  16. Personal radiation monitoring

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    This report reviews the context of a primary university course in individual radiation monitoring. A brief account of the regulations and permissible doses is given. The principles and design of film dosemeters, thermoluminescent dosemeters and the whole-body counting technique are treated

  17. Pump monitoring and analysis

    International Nuclear Information System (INIS)

    Guy, K.R.

    1992-01-01

    The paper describes how to set up a periodic vibration monitoring program implemented with electronic data loggers. Acquired data will be analyzed and evaluated to determine pump condition. Periodic measuring frequency, reporting procedures, and conditions of mechanical components are discussed in detail based on the actual case study

  18. AIR RADIOACTIVITY MONITOR

    Science.gov (United States)

    Bradshaw, R.L.; Thomas, J.W.

    1961-04-11

    The monitor is designed to minimize undesirable background buildup. It consists of an elongated column containing peripheral electrodes in a central portion of the column, and conduits directing an axial flow of radioactively contaminated air through the center of the column and pure air through the annular portion of the column about the electrodes. (AEC)

  19. Ractor stability monitor

    International Nuclear Information System (INIS)

    Takeuchi, Yutaka.

    1991-01-01

    A stability monitor for a BWR type reactor determines the index of stability by statistic processing of signals from an average power region monitor or the like, but it takes much time and the reliability thereof is not always high. Then, parameters such as reactor core power are measured on every sampling periods as observation data and pretreatments such as normalization are applied successively, to obtain monitored amount and store them successively. Differentiation coefficient relative to time are calculated by using the observed amount at present and that one sample period before, to evaluate on a phasal plane using the amount of observation and the differentiation coefficient with time on the axes of coordinate. As a result, information relative to the stability can be represented accurately, thereby enabling to monitor the stability at a high accuracy. Further, judgement for the condition considering the amplitude is conducted upon oscillation, thereby enabling to conduct control operation certainly. The operation in a region where it has been limited under great caution can be conducted appropriately and safely, enabling to conduct controlled operation of excellent economical property. (N.H.)

  20. Community Radiation Monitoring Program

    International Nuclear Information System (INIS)

    Lucas, R.P. Jr.; Cooper, E.N.; McArthur, R.D.

    1990-05-01

    The Community Radiation Monitoring Program began its ninth year in the summer of 1989, continuing as an essential portion of the Environmental Protection Agency's long-standing off-site monitoring effort. It is a cooperative venture between the Department of Energy (DOE), the Environmental Protection Agency (EPA), the University of Utah (U of U), and the Desert Research Institute (DRI) of the University of Nevada System. The objectives of the program include enhancing and augmenting the collection of environmental radiation data at selected sites around the Nevada Test Site (NTS), increasing public awareness of that effort, and involving, in as many ways as possible, the residents of the off-site area in these and other areas related to testing nuclear weapons. This understanding and improved communication is fostered by hiring residents of the communities where the monitoring stations are located as program representatives, presenting public education forums in those and other communities, disseminating information on radiation monitoring and related subjects, and developing and maintaining contacts with local citizens and elected officials in the off-site areas. 8 refs., 4 figs., 4 tabs

  1. Bolt Stress Monitor

    Science.gov (United States)

    1978-01-01

    In photo, an engineer is using a new Ultrasonic Bolt Stress Monitor developed by NASA's Langley Research Center to determine whether a bolt is properly tightened. A highly accurate device, the monitor is an important tool in construction of such structures as pressure vessels, bridges and power plants, wherein precise measurement of the stress on a tightened bolt is critical. Overtightened or undertightened bolts can fail and cause serious industrial accidents or costly equipment break-downs. There are a number of methods for measuring bolt stress. Most widely used and least costly is the torque wrench, which is inherently inaccurate; it does not take into account the friction between nut and bolt, which has an influence on stress. At the other end of the spectrum, there are accurate stress-measuring systems, but they are expensive and not portable. The battery-powered Langley monitor fills a need; it is inexpensive, lightweight, portable and extremely accurate because it is not subject to friction error. Sound waves are transmitted to the bolt and a return signal is received. As the bolt is tightened, it undergoes changes in resonance due to stress, in the manner that a violin string changes tone when it is tightened. The monitor measures the changes in resonance and provides a reading of real stress on the bolt. The device, patented by NASA, has aroused wide interest and a number of firms have applied for licenses to produce it for the commercial market.

  2. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  3. Environmental monitoring programme

    International Nuclear Information System (INIS)

    Schroeder, H.J.

    1981-01-01

    The tasks of the radiation protection department at a nuclear power plant are mentioned and described. Special attention is given to the environmental monitoring program. The consequences from regulations, the different items in the program and the results are described. (orig./RW)

  4. (Multiawesome) Multispectral Multiprobe Monitoring

    International Nuclear Information System (INIS)

    Scheibelhofer, Otto; Hohl, Roland; Sacher, Stefan; Menezes, Jose; Khinast, Johannes

    2012-01-01

    Full text: In the food and pharmaceutical industry, near-infrared spectroscopy is a more and more frequently used tool for process monitoring. This is motivated by its fast and non-invasive nature. Further on, no extensive sample preparation is needed, enabling the use as an online process analytical tool. However, this comes with the drawback of large amounts of correlated data, often influenced by many external factors. Therefore, a lot of effort has to be invested in the correct use of mathematical tools to extract the information of interest. Here we put to use a new prototype NIR spectrometer (by EVK, Raaba, Austria), based on an established chemical imaging system, to enable the reading of several attached probes at the same time. However, even when investigating the same sample, there are slight differences from one probe to another. On the one hand, this is caused by their different eld of view; on the other hand, these are to be avoided disturbances, on nominally similar probes. Therefore, it is necessary to identify these disturbances and consider them in the spectral interpretation. This should allow the monitoring of processes at different positions, as well as the simultaneous monitoring of different processes, with one measurement system. In this work, data from the prototype system are presented in use on a pharmaceutical process. It is shown how to overcome some of the appearing difficulties when dealing with a multiprobe system, in order to enable fast and robust process monitoring, and render process control. (author)

  5. Poverty monitor 2007

    NARCIS (Netherlands)

    Cok Vrooman; Stella Hoff; Ferdy Otten; Wim Bos

    2007-01-01

    Original title: Armoedemonitor 2007. The Poverty Monitor 2007 contains the most up-to-date figures on poverty in the Netherlands. The data were collected and analysed by the Netherlands Institute for Social Research/SCP in collaboration with Statistics Netherlands (CBS). The report describes

  6. Poverty Monitor 2003

    NARCIS (Netherlands)

    Cok Vrooman; Henk-Jan Dirven; Stella Hoff; Ger Linden

    2003-01-01

    Original title: Armoedemonitor 2003. The Poverty Monitor 2003 (Armoedemonitor 2003) contains the most up-to-date figures on poverty in the Netherlands. The data were collected and analysed by the Netherlands Institute for Social Research/SCP and Statistics Netherlands (CBS). The extent of and

  7. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  8. Poverty Monitor 1998

    NARCIS (Netherlands)

    1998-01-01

    Original title: Armoedemonitor 1998. The Poverty Monitor 1998 (Armoedemonitor 1998) presents a complete and up-to-date picture of poverty in the Netherlands. It is intended to provide a factual basis for the current debate on poverty. The Netherlands Institute for Social Research/SCP and

  9. Poverty Monitor 2001

    NARCIS (Netherlands)

    2001-01-01

    Original title: Armoedemonitor 2001. The Poverty Monitor 2001 (Armoedemonitor 2001) contains the most up-to-date figures on poverty in the Netherlands. The data were collected and analysed by the Netherlands Institute for Social Research/SCP and Statistics Netherlands (CBS). The extent of and

  10. Poverty Monitor 1999

    NARCIS (Netherlands)

    1999-01-01

    Original title: Armoedemonitor 1999. The Poverty Monitor 1999 (Armoedemonitor 1999) presents as complete and up-to-date a picture as possible of poverty in the Netherlands, and thus provides a factual basis for the debate on poverty. The Netherlands Institute for Social Research/SCP

  11. Poverty Monitor 2000

    NARCIS (Netherlands)

    2000-01-01

    Original title: Armoedemonitor 2000. The Poverty Monitor 2000 (Armoedemonitor 2000) contains the most up-to-date figures on poverty in the Netherlands. The data were collected and analysed by the Netherlands Institute for Social Research/SCP and Statistics Netherlands (CBS). The extent of

  12. Beam profile monitor

    International Nuclear Information System (INIS)

    Krausse, G.J.; Gram, P.A.M.

    1978-05-01

    A system used to monitor secondary beam profiles at the LAMPF Linac for channel tune-up and diagnostics is described. The multiwire proportional chamber design is discussed, and descriptions and drawings of the gate card, the amplifier/multiplexer card, the output amplifier card, and the overall system are given

  13. LGBT Monitor 2016

    NARCIS (Netherlands)

    Lisette Kuyper

    2016-01-01

    Original title: LHBT-monitor 2016 What is the public attitude today towards lesbian, homosexual, bisexual and transgender (LGBT) persons? What do large-scale population surveys enable us to say about their position in society? The Netherlands is one of the most positive countries in Europe in its

  14. Value activity monitoring

    NARCIS (Netherlands)

    de Alencar Silva, P.

    2013-01-01

    Current value modeling ontologies are grounded on the economic premise that profit sharing is a critical condition to be assessed during the configuration of a value constellation. Such a condition ought to be reinforced through a monitoring mechanism design, since a value model expresses only

  15. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  16. Monitoring selected arthropods

    Science.gov (United States)

    R. Chris Stanton; David J. Horn; Foster F. Purrington; John W. Peacock; Eric H. Metzler

    2003-01-01

    Arthropod populations were sampled in four study areas in southern Ohio in 1995 to document patterns of arthropod diversity and establish a baseline dataset for long-term monitoring in mixed-oak forests. Pitfall, Malaise, and blacklight traps were operated in 12 treatment units from May through September. Several insect groups were selected for detailed study due to...

  17. Luminosity monitor at PEP

    International Nuclear Information System (INIS)

    Fox, J.D.; Franklin, M.E.B.

    1981-02-01

    The luminosity monitor system utilized by the MKII Detector and by the PEP operators is described. This system processes information from 56 photomultipliers and calculates independent luminosities for each of the 3 colliding bunches in PEP. Design considerations, measurement techniques, and sources of error in the luminosity measurement are discussed

  18. Nuclear reactor monitoring device

    International Nuclear Information System (INIS)

    Mihashi, Ishi; Honma, Hitoshi.

    1993-01-01

    The monitoring device of the present invention comprises a reactor core/reactor system data measuring and controlling device, a radioactivity concentration calculation device for activated coolants for calculating a radioactivity concentration of activated coolants in a main steam and reactor water by using an appropriate physical model, a radioactivity concentration correlation and comparison device for activated coolants for comparing correlationship with a radiation dose and an abnormality alarm device. Since radioactivity of activated primary coolants is monitored at each of positions in the reactor system and occurrence of leakage and the amount thereof from a primary circuit to a secondary circuit is monitored if the reactor has secondary circuit, integrity of the reactor system can be ensured and an abnormality can be detected rapidly. Further, radioactivity concentration of activated primary circuit coolants, represented by 16 N or 15 C, is always monitored at each of positions of PWR primary circuits. When a heat transfer pipe is ruptured in a steam generator, leakage of primary circuit coolants is detected rapidly, as well as the amount of the leakage can be informed. (N.H.)

  19. EMon: Embodied Monitorization

    Science.gov (United States)

    Carneiro, Davide; Novais, Paulo; Costa, Ricardo; Gomes, Pedro; Neves, José

    The amount of seniors in need of constant care is rapidly rising: an evident consequence of population ageing. There are already some monitorization environments which aim to monitor these persons while they remain at home. This, however, although better than delocalizing the elder to some kind of institution, may not still be the ideal solution, as it forces them to stay inside the home more than they wished, as going out means lack of accompaniment and a consequent sensation of fear. In this paper we propose EMon: a monitorization device small enough to be worn by its users, although powerful enough to provide the higher level monitorization systems with vital information about the user and the environment around him. We hope to allow the representation of an intelligent environment to move with its users, instead of being static, mandatorily associated to a single physical location. The first prototype of EMon, as presented in this paper, provides environmental data as well as GPS coordinates and pictures that are useful to describe the context of its user.

  20. Neuropharmacology of performance monitoring.

    Science.gov (United States)

    Jocham, Gerhard; Ullsperger, Markus

    2009-01-01

    Adaptive, goal-directed behavior requires that organisms evaluate their actions in terms of their outcomes. Neuroimaging studies show that unfavorable outcomes or situations with high level of conflict engage the posterior medial frontal cortex (pMFC). Recording of event-related potentials revealed that these situations are accompanied by a negative deflection, the so-called error-related negativity (ERN), which appears after an erroneous response or after negative feedback. Both activation of the pMFC and the ERN are thought to represent a signal that indicates the need for behavioral adjustment, and to recruit other brain regions that implement these adjustments. While many fMRI and EEG studies have shed light on the anatomical structures and the cognitive processes involved in performance monitoring, only very recently have researchers begun to investigate the underlying neurochemical mechanisms. Drawing on the putative involvement of dopamine (DA) neurons in coding a reward prediction error, an influential theory has ascribed a pivotal role to DA in performance monitoring. However, although important, DA is certainly not the only neuromodulator involved. Recent studies point to a role for serotonin, norepinephrine and GABA, but also for adenosine in performance monitoring. Here, we review the evidence for neurotransmitter effects on this function in humans. In this light, we critically discuss currently debated models of performance monitoring and potential alternatives.

  1. Monitoring of operating processes

    International Nuclear Information System (INIS)

    Barry, R.F.

    1981-01-01

    Apparatus is described for monitoring the processes of a nuclear reactor to detect off-normal operation of any process and for testing the monitoring apparatus. The processes are evaluated by response to their paramters, such as temperature, pressure, etc. The apparatus includes a pair of monitoring paths or signal processing units. Each unit includes facilities for receiving on a time-sharing basis, a status binary word made up of digits each indicating the status of a process, whether normal or off-normal, and test-signal binary words simulating the status binary words. The status words and test words are processed in succession during successive cycles. During each cycle, the two units receive the same status word and the same test word. The test words simulate the status words both when they indicate normal operation and when they indicate off-normal operation. Each signal-processing unit includes a pair of memories. Each memory receives a status word or a test word, as the case may be, and converts the received word into a converted status word or a converted test word. The memories of each monitoring unit operate into a non-coincidence which signals non-coincidence of the converted word out of one memory of a signal-processing unit not identical to the converted word of the other memory of the same unit

  2. Community Radiation Monitoring Program

    International Nuclear Information System (INIS)

    Cooper, E.N.

    1993-05-01

    The Community Radiation Monitoring Program (CRMP) is a cooperative effort between the US Department of Energy (DOE); the US Environmental Protection Agency (EPA); the Desert Research Institute (DRI), a division of the University and Community College System of Nevada and the Nuclear Engineering Laboratory of the University of Utah (UNEL). The twelfth year of the program began in the fall of 1991, and the work continues as an integral part of the DOE-sponsored long-term offsite radiological monitoring effort that has been conducted by EPA and its predecessors since the inception of nuclear testing at the Nevada Test Site (NTS). The program began as an outgrowth of activities that occurred during the Three Mile Island incident in 1979. The local interest and public participation that took place there were thought to be transferrable to the situation at the NTS, so, with adaptations, that methodology was implemented for this program. The CRMP began by enhancing and centralizing environmental monitoring and sampling equipment at 15 communities in the existing EPA monitoring network, and has since expanded to 19 locations in Nevada, Utah and California. The primary objectives of this program are still to increase the understanding by the people who live in the area surrounding the NTS of the activities for which DOE is responsible, to enhance the performance of radiological sampling and monitoring, and to inform all concerned of the results of these efforts. One of the primary methods used to improve the communication link with people in the potentially impacted area has been the hiring and training of local citizens as station managers and program representatives in those selected communities in the offsite area. These managers, active science teachers wherever possible, have succeeded, through their training, experience, community standing, and effort, in becoming a very visible, able and valuable asset in this link

  3. Monitoring volatile anaesthetic agents

    International Nuclear Information System (INIS)

    Russell, W.J.

    2000-01-01

    Full text: The methods that have been used for monitoring volatile anaesthetic agents depend on some physical property such as Density, Refractometry, Mass, Solubility, Raman scattering, or Infra-red absorption. Today, refractometry and infra-red techniques are the most common. Refractometry is used for the calibration of vaporizers. All anaesthetic agents increase the refractive index of the carrier gas. Provided the mixture is known then the refractive change measures the concentration of the volatile anaesthetic agent. Raman Scattering is when energy hits a molecule a very small fraction of the energy is absorbed and re-emitted at one or more lower frequencies. The shift in frequency is a function of the chemical bonds and is a fingerprint of the substance irradiated. Electromagnetic (Infra-red) has been the commonest method of detection of volatile agents. Most systems use a subtractive system, i.e. the agent in the sampling cell absorbed some of the infrared energy and the photo-detector therefore received less energy. A different approach is where the absorbed energy is converted into a pressure change and detected as sound (Acoustic monitor). This gives a more stable zero reference. More recently, the detector systems have used multiple narrow-band wavelengths in the infrared bands and by shape matching or matrix computing specific agent identification is achieved and the concentration calculated. In the early Datex AS3 monitors, a spectral sweep across the 3 micron infrared band was used to create spectral fingerprints. The recently released AS3 monitors use a different system with five very narrow band filters in the 8-10 micron region. The transmission through each of these filters is a value in a matrix which is solved by a micro computer to identify the agent and its concentration. These monitors can assist in improving the safety and efficiency of our anaesthetics but do not ensure that the patient is completely anaesthetized. Copyright (2000

  4. Monitoring volatile anaesthetic agents

    Energy Technology Data Exchange (ETDEWEB)

    Russell, W J [Royal Adelaide Hospital, SA (Australia). Department of Anaesthesia and Intensive Care

    2000-12-01

    Full text: The methods that have been used for monitoring volatile anaesthetic agents depend on some physical property such as Density, Refractometry, Mass, Solubility, Raman scattering, or Infra-red absorption. Today, refractometry and infra-red techniques are the most common. Refractometry is used for the calibration of vaporizers. All anaesthetic agents increase the refractive index of the carrier gas. Provided the mixture is known then the refractive change measures the concentration of the volatile anaesthetic agent. Raman Scattering is when energy hits a molecule a very small fraction of the energy is absorbed and re-emitted at one or more lower frequencies. The shift in frequency is a function of the chemical bonds and is a fingerprint of the substance irradiated. Electromagnetic (Infra-red) has been the commonest method of detection of volatile agents. Most systems use a subtractive system, i.e. the agent in the sampling cell absorbed some of the infrared energy and the photo-detector therefore received less energy. A different approach is where the absorbed energy is converted into a pressure change and detected as sound (Acoustic monitor). This gives a more stable zero reference. More recently, the detector systems have used multiple narrow-band wavelengths in the infrared bands and by shape matching or matrix computing specific agent identification is achieved and the concentration calculated. In the early Datex AS3 monitors, a spectral sweep across the 3 micron infrared band was used to create spectral fingerprints. The recently released AS3 monitors use a different system with five very narrow band filters in the 8-10 micron region. The transmission through each of these filters is a value in a matrix which is solved by a micro computer to identify the agent and its concentration. These monitors can assist in improving the safety and efficiency of our anaesthetics but do not ensure that the patient is completely anaesthetized. Copyright (2000

  5. Selective noble gases monitoring

    International Nuclear Information System (INIS)

    Janecka, S.; Jancik, O.; Kapisovsky, V.; Kubik, I.; Sevecka, S.

    1995-01-01

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: 88 Kr(67; 22) Bq/m 3 ; 85m Kr(17; 7) Bq/m 3 ; 135m Xe(7.1; 0.5) Bq/m 3 ; 138 Xe(5.9; 0.9) Bq/m 3 . (J.K.)

  6. Selective noble gases monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Janecka, S; Jancik, O; Kapisovsky, V; Kubik, I; Sevecka, S [Nuclear Power Plants Research Institute, a.s., Trnava (Slovakia)

    1996-12-31

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: {sup 88}Kr(67; 22) Bq/m{sup 3}; {sup 85m}Kr(17; 7) Bq/m{sup 3}; {sup 135m}Xe(7.1; 0.5) Bq/m{sup 3}; {sup 138}Xe(5.9; 0.9) Bq/m{sup 3}. (J.K.).

  7. Quantitative analysis of wild-type and V600E mutant BRAF proteins in colorectal carcinoma using immunoenrichment and targeted mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hang [Molecular Medicine Research Center, Chang Gung University, Taoyuan, Taiwan (China); Department of Cell Biology, Key Laboratory of Cell Biology, Ministry of Public Health, and Key Laboratory of Medical Cell Biology, Ministry of Education, China Medical University, Shenyang 110122 (China); Hsiao, Yung-Chin [Molecular Medicine Research Center, Chang Gung University, Taoyuan, Taiwan (China); Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan (China); Chiang, Sum-Fu [Division of Colon and Rectal Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan (China); Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Wu, Chia-Chun; Lin, Yu-Tsun [Graduate Institute of Biomedical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Liu, Hsuan [Molecular Medicine Research Center, Chang Gung University, Taoyuan, Taiwan (China); Division of Colon and Rectal Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan (China); Graduate Institute of Biomedical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Department of Cell and Molecular Biology, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Zhao, Hong [Experimental Center of Functional Subjects, College of Basic Medicine, China Medical University, Shenyang, Liaoning 110122 (China); Chen, Jinn-Shiun [Division of Colon and Rectal Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan (China); Chang, Yu-Sun [Molecular Medicine Research Center, Chang Gung University, Taoyuan, Taiwan (China); Department of Otolaryngology, Chang Gung Memorial Hospital, Linkou, Taiwan (China); and others

    2016-08-24

    The BRAF V600E mutation is one of the most common mutations implicated in the development of several types of cancer including colorectal cancer (CRC), where it is associated with aggressive disease phenotypes and poor outcomes. The status of the BRAF V600E mutation is frequently determined by direct DNA sequencing. However, no previous study has sought to quantify the BRAF V600E protein in cancer specimens. Here, we evaluated immunoenrichment coupled with two MS-based quantitative techniques, namely multiple reaction monitoring (MRM) and single ion monitoring conjugated accurate inclusion mass screening (SIM-AIMS), to detect and precisely quantify wild-type (WT) and V600E mutant BRAF proteins in DNA sequence-confirmed CRC tissue specimens. WT and V600E BRAF proteins were immunoprecipitated from a CRC cell line (HT-29), and their representative peptides ({sup 592}IGDFGLATVK{sup 601} and {sup 592}IGDFGLATEK{sup 601}, respectively) were confirmed by LC-MS/MS analysis and then quantified by MRM or SIM-AIMS with spiked stable isotope-labeled peptide standards. Both assays worked well for measuring WT BRAF from different amounts of HT-29 cell lysates, but the MRM assay was more sensitive than SIM-AIMS assay for quantifying lower levels of V600E BRAF. In protein extracts (2 mg) from 11 CRC tissue specimens, the MRM assay could measure WT BRAF in all 11 cases (0.32–1.66 ng) and the V600E BRAF in two cases (0.1–0.13 ng; mutant-to-WT ratio, 0.16–0.17). The SIM-AIMS assay could also detect WT and V600E BRAF in CRC specimens, but the measured levels of both targets were lower than those determined by MRM assay. Collectively, this study provides an effective method to precisely quantify WT and V600E BRAF proteins in complex biological samples using immunoenrichment-coupled targeted MS. Since the V600E BRAF protein has emerged as an important therapeutic target for cancer, the developed assay should facilitate future BRAF-related basic and clinical studies

  8. Rulison Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-07-01

    The Project Rulison Monitoring Plan has been developed as part of the U.S. Department of Energy (DOE) Office of Legacy Management's mission to protect human health and the environment. The purpose of the plan is to monitor fluids from gas wells for radionuclides that would indicate contamination is migrating from the Rulison detonation zone to producing gas wells, allowing action to be taken before the contamination could pose a risk. The Monitoring Plan (1) lists the contaminants present and identifies those that have the greatest potential to migrate from the detonation zone (radionuclide source term), (2) identifies locations that monitor the most likely transport pathways, (3) identifies which fluids will be sampled (gas and liquid) and why, (4) establishes the frequency of sampling, and (5) specifies the most practical analyses and where the analysis results will be reported. The plan does not affect the long-term hydrologic sampling conducted by DOE since 1972, which will continue for the purpose of sampling shallow groundwater and surface water near the site. The Monitoring Plan was developed in anticipation of gas wells being drilled progressively nearer the Rulison site. DOE sampled 10 gas wells in 1997 and 2005 at distances ranging from 2.7 to 7.6 miles from the site to establish background concentrations for radionuclides. In a separate effort, gas industry operators and the Colorado Oil and Gas Conservation Commission (COGCC) developed an industry sampling and analysis plan that was implemented in 2007. The industry plan requires the sampling of gas wells within 3 miles of the site, with increased requirements for wells within 1 mile of the site. The DOE plan emphasizes the sampling of wells near the site (Figure 1), specifically those with a bottom-hole location of 1 mile or less from the detonation, depending on the direction relative to the natural fracture trend of the producing formation. Studies indicate that even the most mobile

  9. Towards innovative roadside monitoring

    Science.gov (United States)

    Ojha, G.; Appel, E.; Magiera, T.

    2012-04-01

    Soil contamination along roadsides is an important factor of anthropogenic point source pollution. Climatic and traffic-specific factors influence the amount and characteristics of pollution emitted and deposited in the roadside soil. In our present study we focus on monitoring typical traffic pollutants (heavy metals HM, platinum group elements, polycyclic hydrocarbons PAH), and investigate the use of magnetic parameters, especially magnetic susceptibility (MS) as proxy. Monitoring plots were installed along roadside in areas with different climatic conditions and different traffic-specific activities (traffic density and speed, vehicle types, abrasion of tires, brake linings, petrol/diesel compounds and road maintenance). For monitoring we removed 10-15 cm of top soil at 1 m distance from the roadside edge and placed 30 plastic boxes there filled with clean quartz sand, to be sampled after regular intervals within two years. Preliminary data from the first year of monitoring are presented. Magnetic results revealed that a coarse grained magnetite-like phase is responsible for the enhancement of magnetic concentration. The mass-specific MS and concentration of pollutants (HM, PAH) all show a significant increase with time, however, there are obviously also seasonal and site-dependent effects which lead to more stable values over several months or even some decrease in the upper few cm due to migration into depth. Source identification indicates that the accumulated PAHs are primarily emissions from traffic. In order to be able to discriminate in between different kinds of transport and deposition (surface run off from the road and neighbouring soil material, splash water, air transport), we additionally established pillars at the roadside with clean quartz sampling boxes at different heights (surface, 0.5 m, 2 m). As a first surprising result we observed that the increase in the boxes at surface is not necessarily higher than at 0.5 m height. The results from our

  10. Final Report Technetium Monitor

    International Nuclear Information System (INIS)

    Spencer, W.A.

    2003-01-01

    The Hanford River Protection Project Waste Treatment Plant (WTP) is required by the current contract to remove radioactive technetium FR-om stored caustic nuclear waste solutions. The Savannah River Technology Center (SRTC) has worked with typical envelopes of these wastes to optimize the removal process. To support the studies, SRTC developed a rapid on-line remote analyzer to monitor technetium and rhenium levels in solutions as well as track other metals in the solutions through the process operations. Rhenium was used as a non-radioactive substitute for technetium in process development studies. The remote monitor was based on inductively coupled plasma emission spectroscopy (ICPES). Fiber optic cable and extended RF cabling removed the plasma source FR-om the spectrometer and instrument electronics

  11. Remote monitoring demonstration

    International Nuclear Information System (INIS)

    Caskey, Susan; Olsen, John

    2006-01-01

    The recently upgraded remote monitoring system at the Joyo Experimental Reactor uses a DCM-14 camera module and GEMINI software. The final data is compatible both with the IAEA-approved GARS review software and the ALIS software that was used for this demonstration. Features of the remote monitoring upgrade emphasized compatibility with IAEA practice. This presentation gives particular attention to the selection process for meeting network security considerations at the O'arai site. The Joyo system is different from the NNCA's ACPF system, in that it emphasizes use of IAEA standard camera technology and data acquisition and transmission software. In the demonstration itself, a temporary virtual private network (VPN) between the meeting room and the server at Sandia in Albuquerque allowed attendees to observe data stored from routine transmissions from the Joyo Fresh Fuel Storage to Sandia. Image files from a fuel movement earlier in the month showed Joyo workers and IAEA inspectors carrying out a transfer. (author)

  12. Monitoring the normal body

    DEFF Research Database (Denmark)

    Nissen, Nina Konstantin; Holm, Lotte; Baarts, Charlotte

    2015-01-01

    of practices for monitoring their bodies based on different kinds of calculations of weight and body size, observations of body shape, and measurements of bodily firmness. Biometric measurements are familiar to them as are health authorities' recommendations. Despite not belonging to an extreme BMI category...... provides us with knowledge about how to prevent future overweight or obesity. This paper investigates body size ideals and monitoring practices among normal-weight and moderately overweight people. Methods : The study is based on in-depth interviews combined with observations. 24 participants were...... recruited by strategic sampling based on self-reported BMI 18.5-29.9 kg/m2 and socio-demographic factors. Inductive analysis was conducted. Results : Normal-weight and moderately overweight people have clear ideals for their body size. Despite being normal weight or close to this, they construct a variety...

  13. Environmental monitoring report, 1976

    International Nuclear Information System (INIS)

    1977-01-01

    The effluent and environmental monitoring programs maintained by the Pinellas Plant are designed to determine the efficiencies of treatment and control mechanisms; to provide measurements of discharge concentrations for comparison with applicable standards; and to assess the concentrations of these discharges in the environment. Site perimeter and off-site air samples for tritium gas and tritium oxide, as well as off-site surface water samples obtained to distances of 9.6 kilometers (6 miles) from the plant site and analyzed for tritium content, showed levels significantly less than 1 / 10 of 1 percent of the recommended guide for continuous nonoccupational exposure. Small sealed plutonium sources are utilized at this site. No plutonium was released to the environment and monitoring data showed environmental background levels

  14. Portable radiation monitors

    International Nuclear Information System (INIS)

    Masui, Kaoru; Ishikura, Takeshi; Inui, Daisuke

    2007-01-01

    This paper presents an overview of typical portable radiation monitors and introduces Fuji Electric's latest models. The overview describes the types, uses and performance of ion chamber survey meters, GM survey meters and neutron ambient dose equivalent rate meters. Fuji Electric's new model of a wide-energy-range X/gamma ray survey meter which measures low energy X-rays up to 8 keV, a battery-powered environmental dosemeter system which measures dose history and is capable of continuous measurement with batteries over a year, and a portable monitoring post which measures dose rates from background to 10 8 nGy/h and transmits data by cellular phone are introduced, and their specifications and performance are described. (author)

  15. A Novel Pseudoerror Monitor

    Directory of Open Access Journals (Sweden)

    Wang Peng

    2004-01-01

    Full Text Available The error rate (ER is a crucial criterion in evaluating the performance of a digital communication system. Many ER estimation methods have been described in the literature. Among them, the pseudoerror monitoring solution has attracted special attention due to its consistent performance in different environments and distinctive blind estimation capability, that is, estimating the ER without needing any prior knowledge of the transmitted information. In this paper, a novel pseudoerror monitor (PEM design, the kernel PEM, is developed. Incorporating the strength of the probability density function (pdf approximation technique, the proposed design has remarkable advantage of being able to produce statistically consistent ER estimate within a much shorter observation time. Simulation results are given in support of this claim.

  16. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  17. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  18. OLYMPUS luminosity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ates, Ozgur [Hampton University, Hampton, Virginia (United States); Collaboration: OLYMPUS-Collaboration

    2013-07-01

    The OLYMPUS experiment at DESY has been measuring the ratio of positron-proton and electron-proton elastic scattering cross sections to quantify the effect of two-photon exchange, which is widely considered to be responsible for the discrepancy between measurements of the proton electric to magnetic form factor ratio with the Rosenbluth and polarization transfer methods. In order to control the systematic uncertainties to the percent level, the luminosities are monitored redundantly with high precision by measuring the rates for symmetric Moller and Bhabha scattering, and by measuring the ep-elastic count rates at forward angles and low momentum transfer with tracking telescopes based on GEM (Gas Electron Multiplier) and MWPC (Multi Wire Proportional Chamber) technology. During two data taking periods, performances of GEM and MWPC luminosity monitors are presented.

  19. Method for radioactivity monitoring

    Science.gov (United States)

    Umbarger, C. John; Cowder, Leo R.

    1976-10-26

    The disclosure relates to a method for analyzing uranium and/or thorium contents of liquid effluents preferably utilizing a sample containing counting chamber. Basically, 185.7-keV gamma rays following .sup.235 U alpha decay to .sup.231 Th which indicate .sup.235 U content and a 63-keV gamma ray doublet found in the nucleus of .sup.234 Pa, a granddaughter of .sup.238 U, are monitored and the ratio thereof taken to derive uranium content and isotopic enrichment .sup.235 U/.sup.235 U + .sup.238 U) in the liquid effluent. Thorium content is determined by monitoring the intensity of 238-keV gamma rays from the nucleus of .sup.212 Bi in the decay chain of .sup.232 Th.

  20. Embodied-self-monitoring

    DEFF Research Database (Denmark)

    Bagalkot, Naveen L.

    -hardware drove this co-evolution in collaboration with the rehabilitees, their spouses, and their professional therapists. The explorations resulted in a ‘compositional whole’. This compositional whole is constituted by the theoretical concept of embodied-self-monitoring; the various scenarios of possible...... for compliance. I formulate the theoretical concept of ‘embodied-self-monitoring’ to orient the design towards embracing the embodied actions of the rehabilitees through which they make sense of complying with the therapy. The central argument of this thesis is that the theoretical concept of embodied....... I follow a concept-driven interaction design research process. This is a dialectic process where both the understanding of what is embodied-self-monitoring and what prospects it offers co-evolved through the two groups of design explorations presented in this thesis. A process of sketching -in...

  1. Reactor power monitoring device

    International Nuclear Information System (INIS)

    Dogen, Ayumi; Ozawa, Michihiro.

    1983-01-01

    Purpose: To significantly improve the working efficiency of a nuclear reactor by reflecting the control rod history effect on thermal variants required for the monitoring of the reactor operation. Constitution: An incore power distribution calculation section reads the incore neutron fluxes detected by neutron detectors disposed in the reactor to calculate the incore power distribution. A burnup degree distribution calculation section calculates the burnup degree distribution in the reactor based on the thus calculated incore power distribution. A control rod history date store device supplied with the burnup degree distribution renews the stored control rod history data based on the present control rod pattern and the burnup degree distribution. Then, thermal variants of the nuclear reactor are calculated based on the thus renewed control rod history data. Since the control rod history effect is reflected on the thermal variants required for the monitoring of the reactor operation, the working efficiency of the nuclear reactor can be improved significantly. (Seki, T.)

  2. Radiation monitor reporting requirements

    International Nuclear Information System (INIS)

    Bates, W.F.

    1993-01-01

    Within High-Level Waste Management (HLWM), CAMs and VAMPs are currently considered Class B equipment, therefore, alarm conditions associated with the CAMs and VAMPs result in an Unusual Occurrence or Off-Normal notification and subsequent occurrence reporting. Recent equipment difficulties associated with Continuous Air Monitors (CAMs) and Victoreen Area Radiation Monitors (VAMPs) have resulted in a significant number of notification reports. These notification have the potential to decrease operator sensitivity to the significance of specific CAM and VAMP failures. Additionally, the reports are extremely costly and are not appropriate as a means for tracking and trending equipment performance. This report provides a technical basis for a change in Waste Management occurrence reporting categorization for specific CAM and VAMP failure modes

  3. Tritium monitoring techniques

    International Nuclear Information System (INIS)

    DeVore, J.R.; Buckner, M.A.

    1996-05-01

    As part of their operations, the U.S. Navy is required to store or maintain operational nuclear weapons on ships and at shore facilities. Since these weapons contain tritium, there are safety implications relevant to the exposure of personnel to tritium. This is particularly important for shipboard operations since these types of environments can make low-level tritium detection difficult. Some of these ships have closed systems, which can result in exposure to tritium at levels that are below normally acceptable levels but could still cause radiation doses that are higher than necessary or could hamper ship operations. This report describes the state of the art in commercial tritium detection and monitoring and recommends approaches for low-level tritium monitoring in these environments

  4. Monitoring of environmental radioactivity

    International Nuclear Information System (INIS)

    1986-01-01

    The results are described of monitoring radioactivity of atmospheric fallout, surface waters, soils, plant feeds, cereals, and other agricultural produce. The results were obtained over a long time period. Radioactivity was also measured of milk, milk products, vegetables and fruits, meat and hen eggs, flour and bakery products with a view to radionuclide migration in the food chain. The daily intake of 90 Sr and 137 Cs from food was determined from the values obtained and the consumption of the individual types of food. Strontium-90 distribution was studied in the bones and the teeth of the population in Slovakia. With the commissioning of nuclear power plants, emissions and liquid wastes were monitored and their environmental impact assessed. (E.S.)

  5. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  6. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  7. Icinga network monitoring

    CERN Document Server

    Mehta, Viranch

    2013-01-01

    This book is written in a concise and easy-to-follow approach, it will guide you to get you started with Icinga and lead you through the difficult concepts with illustrated examples and screenshots.If you are a system administrator or Linux enthusiast who is looking for a flexible tool to monitor network infrastructure efficiently, or trying to understand the Icinga software, this is a great book for you. You are expected to have solid foundation in Linux.

  8. Alpha-monitoring system

    International Nuclear Information System (INIS)

    Dincklage, R.D. von

    1982-01-01

    A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)

  9. Yacht Race Monitoring

    Science.gov (United States)

    1981-01-01

    Observer Single-handed Transatlantic Race (OSTAR) participants were aided by a French-American space-based monitoring system which reported the yacht's positions throughout the race, and also served as an emergency locator service. Originating from NASA's Nimbus 6 Satellite, use of this system, called ARGOS made the OSTAR competition the most accurately reported sea race ever conducted. Each boat carried a portable transmitter allowing 88 new sources of oceanographic data available during the race.

  10. Nuclear methods monitor nutrition

    International Nuclear Information System (INIS)

    Allen, B.J.

    1988-01-01

    Neutron activation of nitrogen and hydrogen in the body, the isotope dilution technique and the measurement of naturally radioactive potassium in the body are among the new nuclear methods, now under collaborative development by the Australian Nuclear Scientific and Technology Organization and medical specialists from several Sydney hospitals. These methods allow medical specialists to monitor the patient's response to various diets and dietary treatments in cases of cystic fibrosis, anorexia nervosa, long-term surgical trauma, renal diseases and AIDS. ills

  11. Chapter 5: Monitoring results

    DEFF Research Database (Denmark)

    Poel, Bart; Thomsen, Kirsten Engelund; Schultz, Jørgen Munthe

    2003-01-01

    The monitoring results from the IEA Task 13 project "Advanced solar low energy houses" are described in this chapter. The underlying information was collected in the form of questionnaires. The questionnaires were formulated in such a way that participants are provided with a uniform lay......-out to fill in their particular results. Thus it is possible to compare the performances measured, calculated or predicted for the different houses....

  12. Monitoring of environment

    Energy Technology Data Exchange (ETDEWEB)

    Mitsudera, M

    1974-09-01

    The amount of pollutants discharged has now exceeded the environment's natural ability to purify itself. The effect of urbanization is traced especially the degeneration of plants and animals in Tokyo. One of the methods of monitoring plants is remote sensing with multi-band photography and multi-spectroscanning. There is a correlation between the sulfur content of tree leaves and multi-band photograms on red pine trees with a correlation coefficient of -0.862.

  13. Nuclear reactor monitoring system

    International Nuclear Information System (INIS)

    Drummond, C.N.; Bybee, R.T.; Mason, F.L.; Worsham, H.J.

    1976-01-01

    The invention pertains to an improved monitoring system for the neutron flux in a nuclear reactor. It is proposed to combine neutron flux detectors, a thermoelement, and a background radiation detector in one measuring unit. The spatial arrangement of these elements is fixed with great exactness; they are enclosed by an elastic cover and are brought into position in the reactor with the aid of a bent tube. The arrangement has a low failure rate and is easy to maintain. (HP) [de

  14. Genetic monitoring of agrocoenosis

    International Nuclear Information System (INIS)

    Lukin, V.D.

    2005-01-01

    Mutants with high frequency of revertants appearance can be used as biological indicator of genetic monitoring of agrocoenosis. It differs from the initial form in dwarf-size of the shrub, the changed plate of leaf and sterility. The low limit of the mutant sensitiveness on the test of visible reverse mutations to the doses of gamma-irradiation is 0,2 Gy and to the rate of soil contamination by lead is 50 mg per 1 kg of soil. (authors)

  15. Bilevel alarm monitoring multiplexer

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1977-06-01

    This report describes the operation of the Bilevel Alarm Monitoring Multiplexer used in the Adaptive Intrusion Data System (AIDS) to transfer and control alarm signals being sent to the Nova 2 computer, the Memory Controlled Data Processor, and its own integral Display Panel. The multiplexer can handle 48 alarm channels and format the alarms into binary formats compatible with the destination of the alarm data

  16. Poverty Monitor 1999

    OpenAIRE

    1999-01-01

    Original title: Armoedemonitor 1999. The Poverty Monitor 1999 (Armoedemonitor 1999) presents as complete and up-to-date a picture as possible of poverty in the Netherlands, and thus provides a factual basis for the debate on poverty. The Netherlands Institute for Social Research/SCP and Statistics Netherlands (CBS) have together collected and analysed a large amount of data on poverty. The findings are set out in this publication. The report also evaluates some aspects of the policy on povert...

  17. Annex 5. Monitoring committee

    OpenAIRE

    2013-01-01

    Head of monitoring committee: the Research Commission of the govern­ment of French Polynesia. Panel members Representatives of the following organisations: IRD centre in Papeete Oceanologic Center of the Pacific/Ifremer Investment Promotion Authority Environment Division EPIC Vanille Institut Louis-Malardé Gepsun “Natural Substances process engineering” technology platform (cf. Abbreviations) Fisheries Division Economic Affairs Division External Trade Division Development of Industry and the...

  18. Neutral beam monitoring

    International Nuclear Information System (INIS)

    Fink, J.H.

    1979-01-01

    A neutral beam generated by passing accelerated ions through a walled cell containing a low energy neutral gas, such that charge exchange partially neutralizes the high energy beam, is monitored by detecting the current flowing through the cell wall produced by low energy ions which drift to the wall after the charge exchange. By segmenting the wall into radial and longitudinal segments various beam conditions are identified. (U.K.)

  19. RTP Radiation Monitoring System

    International Nuclear Information System (INIS)

    Alfred, S.L.; Mohd Fairus Abdul Farid; Ahmad Nabil Abdul Rahim; Nurhayati Ramli

    2015-01-01

    Radiation Monitoring System aiming to limiting dose exposed to personnel to the lowest level referring to the concept of ALARA (As Low As Reasonably Achievable). Atomic Energy Licensing (Basic Safety Radiation Protection) Regulation 2010 (Act 304) is a baseline to control employee and public radiation protection program and guideline, as well as to meet the requirement of the Occupational Safety and Health 1994 (Act 514). (author)

  20. Open Access Monitor - DK

    DEFF Research Database (Denmark)

    Svendsen, Michael; Hansen, Lars Asger Juel; Andersen, Dorte

    2017-01-01

    Open Access Monitor - DK (OAM-DK) is a 2-year DEFF funded [DEFF.2016-0018] national project running in 2017-2018 with the aim of collecting, documenting and administrating Open Access publishing costs. OAM-DK is lead by Copenhagen University Library under the Royal Danish Library with participation...... of all Danish University Libraries. This poster presents the first results of Open Access costs related to 2015 publications at the The University of Copenhagen....

  1. Targets of operation monitoring

    International Nuclear Information System (INIS)

    Wenger, H.

    1997-01-01

    The condition monitoring system of a nuclear power plant should be an assurance for the user and the authorities that the safety of the installation constantly corresponds to the nominal condition. As soon as deviations from these conditions occur, it should quickly provide fundamentals for corrective measures. It contributes to a high degree of availability of the installation and makes safe and economical operation throughout the whole life of the installation possible. (author) 1 fig

  2. Whole body monitoring - Goiania

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Bertelli Neto, L.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: - Individual from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1). - Occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121,57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was established according to the Cs activity present in the body or to the job to be assigned. In this paper we will present some burden activity curves for Cs 137 as a function of the time elapsed from the first measurement. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity x time curve. (author) [pt

  3. 1984 environmental monitoring report

    International Nuclear Information System (INIS)

    Day, L.E.; Miltenberger, R.P.; Naidu, J.R.

    1985-04-01

    The environmental monitoring program has been designed to ensure that BNL facilities operate such that the applicable environmental standards and effluent control requirements have been met. A listing, as required by DOE Order 5484.1 of BNL facilities, of environmental agencies and permits is provided in the Environmental Program Information Section 3.0, Table B. Since the aquifer underlying Long Island has been designated a ''sole source'' aquifer, the Environmental Protection Agency (EPA) Drinking Water Standards have been used in the assessment of ground water data. However, the limits prescribed in the regulations are not directly applicable to the monitoring well data since (1) the standards apply to a community water supply system, i.e., one serving more than 25 individuals, and (2) the standards represent an annual average concentration. Since the monitoring wells are not components of the Laboratory's water supply system, the EPA drinking water standards are employed as reference criteria to which the surveillance well data is compared. The standards also serve as guidance levels for any appropriate remedial action. 36 refs., 9 figs., 40 tabs

  4. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  5. Radiation monitoring by minicomputer

    International Nuclear Information System (INIS)

    Seamons, M.

    1977-01-01

    Radiation monitoring at the Los Alamos Scientific Laboratory (LASL) ranges from measuring the potential build-up of alpha particle radiation in the offices and laboratories of LASL to the detection of radiation leakage from nuclear tests at the Nevada Test Site (NTS). This paper describes PDP-11 based systems to accomplish both types of monitoring. In the first system, filter papers are collected from monitoring stations around LASL. One filter paper is placed under any of 128 photomultiplier (PM) tubes exposing it to alpha radiation. Alpha particle ''hits'' are recorded in a 64-word hardware FIFO, which interrupts and is read by the computer. The FIFO makes it possible to handle short aggregate alpha particle bursts of up to 10 6 hits/s in a computer that can only process 10 4 hits/s. In the second system, up to 100 current measuring radiation probes feed data from the site of the nuclear test(s) to the computer by microwave. The software system can support three tests simultaneously. Both systems offer a high degree of flexibility in configuring for a new test and in real-time control of such things as channel assignment, selective data retrieval, and output formatting

  6. Radiation protection and monitoring

    International Nuclear Information System (INIS)

    Bruecher, L.; Langmueller, G.; Tuerschmann, G.

    1997-01-01

    The safety, the quality and efficiency of the radiological monitoring systems for block one and two of the NPP Mochovce, designed and delivered by the general designer, should be increased by EUCOM Siemens. Modern, accident resistant and/or more powerful monitoring systems have been designed by Siemens will be added to the existing systems. To achieve this radiation measuring units will be installed inside the hermetic zone, in the reactor hall, at the stack, at the release water system and in the environment in the vicinity of the NPP. The presentation, the storage distribution and the processing of all measuring results also will be optimised by installing a modern high-performance computer system, the so-called Central Radiological Computer System 'CRCS', featuring a high availability. The components will be installed in the relevant control rooms all over the plant. With this computer system it is easy to control the radiation level inside and outside the NPP during normal operation and during and after an accident. Special programs, developed by Siemens support the staff by interpreting the consequences of radioactive releases into the environment and by initiating protection procedures during and after an accident. All functions of the system are available for emergency protection drills and training the staff interruption of the normal control procedure. For the personal protection a digital personal dosimetry system completely considering with the requirements of ICRP 60 and several contamination monitors will be installed. (authors)

  7. Neutron monitoring system

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Arita, Setsuo.

    1994-01-01

    The present invention concerns neutron monitoring for monitoring reactor power, and presents a generation state of abnormal signals by monitoring output signals from neutron sensors, judges abnormal signals at an excessively high level outputted from the sensors to a measuring operator or a reactor operator. That is, a threshold value judging means judges whether a sensor signal exceeds a predetermined threshold value or not. When it exceeds the value, recognition signals are outputted to a memory means. The memory means memorizes the times of input of the recognition signals on every period of interval signals outputted from a reference signal generation means. The memory content of the memory means and the previously inputted hysteresis of the sensor are compared and judged, to determine the extent of the degradation of the sensors and output the result of the judgement and hysteresis information to the display means. The input means accesses to the judging means and the memory means to retrieve and correct the content of the memory means and the hysteresis information inputted to the judging means. (I.S.)

  8. Solar weather monitoring

    Directory of Open Access Journals (Sweden)

    J.-F. Hochedez

    2005-11-01

    Full Text Available Space Weather nowcasting and forecasting require solar observations because geoeffective disturbances can arise from three types of solar phenomena: coronal mass ejections (CMEs, flares and coronal holes. For each, we discuss their definition and review their precursors in terms of remote sensing and in-situ observations. The objectives of Space Weather require some specific instrumental features, which we list using the experience gained from the daily operations of the Solar Influences Data analysis Centre (SIDC at the Royal Observatory of Belgium. Nowcasting requires real-time monitoring to assess quickly and reliably the severity of any potentially geoeffective solar event. Both research and forecasting could incorporate more observations in order to feed case studies and data assimilation respectively. Numerical models will result in better predictions of geomagnetic storms and solar energetic particle (SEP events. We review the data types available to monitor solar activity and interplanetary conditions. They come from space missions and ground observatories and range from sequences of dopplergrams, magnetograms, white-light, chromospheric, coronal, coronagraphic and radio images, to irradiance and in-situ time-series. Their role is summarized together with indications about current and future solar monitoring instruments.

  9. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  10. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  11. Environmental monitoring using lasers

    International Nuclear Information System (INIS)

    Iqbal, M.; Ahmed, N.

    1997-01-01

    Activities of human beings are creating slow and long term changes in the Earth's atmosphere. As the sun provides the driving force for earth's ecosystem, therefore earth's radiation budget is an important parameter. Composition of the atmosphere is of basic importance in determining this radiation budget. Out of the atmospheric species, ozone is of special importance because it filters out much of the solar UV, while certain other molecular species, such as SO/sub 2/ , NO/sub 2/, benzene, toluene and aerosols have very harmful effects on life. Depletion of ozone layer over Antarctic and addition of chemical species to atmosphere and oceans have disturbed our ecosystem seriously. Thorough monitoring of distribution and dynamics of these species is essential for devising any countermeasure for their control. Conventional method of atmospheric monitoring (balloon, rocket or satellite borne sensors) are limited either in range or type of measurement apart from being complex and somewhat expensive. LASER based 'light detection and ranging (LIDAR) technique, on the other hand, enjoys a number of advantages over others. Due to recent developments in LASER technique, on the other hand, enjoys a number of advantages over other. Due to recent developments in LASER technology, LIDARS are economical and very flexible in range and type of measurement. This paper presents an overview of the technique. It includes principle of LIDAR, highlights its applications to the monitoring of atmosphere, biosphere and hydrosphere. (author)

  12. Radiation monitoring system

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  13. A simple condition monitoring model for a direct monitoring process

    NARCIS (Netherlands)

    Christer, A.H.; Wang, Wenbin

    1995-01-01

    This paper addresses the problem of condition monitoring of a component which has available a measure of condition called wear. Wear accumulates over time and monitoring inspections are performed at chosen times to monitor and measure the cumulative wear. If past measurements of wear are available

  14. 1988 Monitoring Activities Review (MAR) of the environmental monitoring program

    International Nuclear Information System (INIS)

    1989-03-01

    The EGandG Idaho Environmental Monitoring (EM) Unit is responsible for coordinating and conducting environmental measurements of radioactive and hazardous contaminants around facilities operated by EGandG Idaho. The EM Unit has several broad program objectives, which include complying with regulatory standards and developing a basis for estimating future impacts of operations at EGandG Idaho facilities. To improve program planning and to provide bases for technical improvement of the monitoring program, the EGandG Environmental Monitoring organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. Previous MAR studies have focused on procedures for all currently monitored media except biota. Biotic monitoring was initiated following the last MAR. This report focuses on all currently monitored media, and includes the first review of biotic monitoring. The review of biotic monitoring has been conducted at a level of detail consistent with initial MAR reports for other parts of the Waste Management Program Facilities Environmental Monitoring Program. The review of the biotic monitoring activities is presented in Section 5.5 of this report. 21 refs., 7 figs., 4 tabs

  15. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  16. Monitoring Your Blood Sugar Level

    Science.gov (United States)

    ... and NutritionHealth Insurance: Understanding What It CoversHigh Homocysteine Level: How It Affects Your Blood VesselsUnderstanding Your Medical ... Health Resources Healthcare Management Monitoring Your Blood Sugar Level Monitoring Your Blood Sugar Level Share Print What ...

  17. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  18. Esophageal pH monitoring

    Science.gov (United States)

    pH monitoring - esophageal; Esophageal acidity test ... Esophageal pH monitoring is used to check how much stomach acid is entering the esophagus. It also checks how well the acid is cleared downward into the ...

  19. Subcriticality monitoring method for reactor

    International Nuclear Information System (INIS)

    Ueda, Makoto.

    1991-01-01

    The present invention accurately monitors the reactor subcriticality and ensures the critical safety, irrespective of the presence or absence of artificial neutron sources. That is, when the subcriticality is monitored upon reactivity changing operation which causes reactivity change to the reactor during shutdown, neutron monitors are disposed at a plurality of monitoring positions. Then, neutron counting ratio before and after conducting the reactivity changing operation is determined. The subcriticality of the reactor is monitored by the ratio and the state of scattering of the ratio of neutron counting rate between each of the neutron monitors. With such procedures, signals of the neutron monitors are used, the characteristic that the change of the signals depend on the change of the neutron multiplication of the reactor core can be utilized whether artificial neutron sources (external neutron sources) are disposed or not. Accordingly, the subcriticality can be monitored more reliably. (I.S.)

  20. Electrostatic beam-position monitor

    CERN Multimedia

    CERN PhotoLab

    1969-01-01

    Electrostatic beam-position monitor installed in its final location (bake-out cover removed). The ISR will contain about 110 of these monitors. Their accuracy is better than 1 mm, their band width about 1 MHz.

  1. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  2. Event monitoring of parallel computations

    Directory of Open Access Journals (Sweden)

    Gruzlikov Alexander M.

    2015-06-01

    Full Text Available The paper considers the monitoring of parallel computations for detection of abnormal events. It is assumed that computations are organized according to an event model, and monitoring is based on specific test sequences

  3. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  4. Iowater Water Quality Monitoring Sites

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This coverage contains points representing monitoring locations on streams, lakes and ponds that have been registered by IOWATER monitors. IOWATER, Iowa's volunteer...

  5. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  6. Lunar Health Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — During the Phase II Lunar Health Monitor program, Orbital Research will develop a second generation wearable sensor suite for astronaut physiologic monitoring. The...

  7. Dose monitoring in nuclear emergency

    International Nuclear Information System (INIS)

    Nan Hongjie; Yang Zhongping; Lei Xin

    2012-01-01

    In order to protect people from irradiation sickness and rebuild the radiation filed in nuclear emergency, personal and environmental dose need to be monitored. The application of TLD in dose monitoring is discussed in this paper. (authors)

  8. Soil monitoring as a part of environment monitoring in Slovakia

    International Nuclear Information System (INIS)

    Kobza, J.

    1997-01-01

    In frame of Soil monitoring system it is going about a lot of methods in advance as follows: methods of soil monitoring sites selection and soil monitoring network construction, as well; methods of soil survey and soil sampling; analytical methods (indicating of chemical, agrochemical and physical properties); soil database and methods of evaluation and interpretation of measured results. The monitoring network was constructed on the base of ecological principles - including the monitoring of all soil types and subtypes, various climatic and emission regions as well as relatively clean regions, lowland and highland. Soil monitoring network in forest land is regular (8 x 8 km) with regard to International monitoring system in Forestry. The soil monitoring network in Slovakia consist of 650 monitoring sites (312 sites in farming land and 338 sites in forest land). In addition soil monitoring network includes also 21 monitoring sites. All monitoring sites are geodesically located and reported on the map at a scale of 1:5000. There are the methods concerning the important soil parameters indication with regard to main soil degradation processes a s follows: soil contamination (heavy metals and organic contaminants); soil acidification; soil salinity; soil erosion (deluometrically by the Cs-137 and remote sensing methods); soil compaction; soil fertility and protection. Analytical control system was elaborated according to Good Laboratory Practice. Evaluation of soil monitoring network results is not simple because it depends on various monitored parameters, on aim of evaluation as well as on the scale of landscape which is object for evaluation. There are used the modern statistical methods in monitoring system which can be: universal; disjunctive; simulated. Used statistical methods are significant for interpretation of measured results as follows: trends in landscape; anisotropy; comparison. The evaluation and interpretation way is very significant with regard not

  9. Protocol Monitoring Energy Conservation; Protocol Monitoring Energiebesparing

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Beleidsstudies, Petten (Netherlands); Mannaerts, H. [Centraal Planburea CPB, Den Haag (Netherlands); Tinbergen, W. [Centraal Bureau voor de Statistiek CBS, Den Haag (Netherlands); Vreuls, H.H.J. [Nederlandse onderneming voor energie en milieu Novem, Utrecht (Netherlands); Wesselink, B. [Rijksinstituut voor Volksgezondheid en Milieuhygiene RIVM, Bilthoven (Netherlands)

    2001-12-01

    On request of the Dutch ministry of Economic Affairs five institutes have collaborated to create a 'Protocol Monitoring Energy Conservation', a common method and database to calculate the amount of energy savings realised in past years. The institutes concerned are the Central Bureau of Statistics (CBS), the Netherlands Bureau for Economic Policy Analysis (CPB), the Energy research Centre of the Netherlands (ECN), the National Agency for Energy and Environment (Novem) and the Netherlands Institute of Public Health and the Environment (RIVM). The institutes have agreed upon a clear definition of energy use and energy savings. The demarcation with renewable energy, the saving effects of substitution between energy carriers and the role of import and export of energy have been elaborated. A decomposition method is used to split up the observed change in energy use in a number of effects, on a national and sectoral level. This method includes an analysis of growth effects, effects of structural changes in production and consumption activities and savings on end use or with more efficient conversion processes. To calculate these effects the total energy use is desegregated as much as possible. For each segment a reference energy use is calculated according to the trend in a variable which is supposed to be representative for the use without savings. The difference with the actual energy use is taken as the savings realised. Results are given for the sectors households, industry, agriculture, services and government, transportation and the energy sector; as well as a national figure. A special feature of the protocol method is the application of primary energy use figures in the determination of savings for end users. This means that the use of each energy carrier is increased with a certain amount, according to the conversion losses caused elsewhere in the energy system. The losses concern the base year energy sector and losses abroad for imports of secondary

  10. Design of tool monitor simulator

    International Nuclear Information System (INIS)

    Yao Yonggang; Deng Changming; Zhang Jia; Meng Dan; Zhang Lu; Wang Zhi'ai; Shen Yang

    2011-01-01

    It is based on tool monitor in Qinshan Nuclear Power Plant for the object of study, and manufacture a tool monitor simulator. The device is designed to automatically emulate-monitor the contamination level of objects for training students. Once if the tool monitor reports the contamination, the students can handle properly. The brief introduction of main function and system design of the simulator are presented in the paper. (authors)

  11. Monitoring in traumatic brain injury.

    Science.gov (United States)

    Matz, P G; Pitts, L

    1997-01-01

    In the past several years, improvements in technology have advanced the monitoring capabilities for patients with TBI. The primary goal of monitoring the patient with TBI is to prevent secondary insults to the brain, primarily cerebral ischemia. Cerebral ischemia may occur early and without clinical correlation and portends a poor outcome. Measurement of ICP is the cornerstone of monitoring in the patient with TBI. Monitoring of ICP provides a measurement of CPP and a rough estimation of CBF. However, with alterations in pressure autoregulation, measurement of CPP does not always allow for determination of CBF. To circumvent this problem, direct measurements of CBF can be performed using clearance techniques (133Xe, N2O, Xe-CT) or invasive monitoring techniques (LDF, TDF, NIRS). Although direct and quantitative, clearance techniques do not allow for continuous monitoring. Invasive CBF monitoring techniques are new, and artifactual results can be problematic. The techniques of jugular venous saturation monitoring and TCD are well established and are powerful adjuncts to ICP monitoring. They allow the clinician to monitor cerebral oxygen extraction and blood flow velocity, respectively, for any given CPP. Use of TCD may predict posttraumatic vasospasm before clinical sequelae. Jugular venous saturation monitoring may detect clinically occult episodes of cerebral ischemia and increased oxygen extraction. Jugular venous saturation monitoring optimizes the use of hyperventilation in the treatment of intracranial hypertension. Although PET and SPECT scanning allow direct measurement of CMRO2, these techniques have limited application currently. Similarly, microdialysis is in its infancy but has demonstrated great promise for metabolic monitoring. EEG and SEP are excellent adjuncts to the monitoring arsenal and provide immediate information on current brain function. With improvements in electronic telemetry, functional monitoring by EEG or SEP may become an important

  12. Monitoring Activities Review action report for the Environmental Monitoring Program

    International Nuclear Information System (INIS)

    Wilhelmsen, R.N.; Wright, K.C.

    1990-12-01

    To improve program planning and to provide bases for technical improvement of the monitoring program, the EG ampersand G Environmental Monitoring (EM) organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. An MAR of the Environmental Monitoring Program was conducted in 1988. This action report identifies and discusses the recommendations of this MAR committee. This action report also identifies the actions already taken by the EM Unit in response to these recommendations, as well as the actions and schedules to be taken. 10 refs

  13. Integrated environmental monitoring -- prototype demonstration

    International Nuclear Information System (INIS)

    Bryce, R.W.; Vail, L.W.; Hostetler, D.D.; Meyer, P.D.; Carlson, T.J.; Miller, P.L.

    1994-01-01

    Groundwater monitoring is an important activity at US Department of Energy (DOE) sites. Monitoring programs at DOE facilities have evolved in response to operational needs at the facilities, public outcries for information, regulatory requirements, DOE orders, and improvements in monitoring technology. Decisions regarding sampling location, sampling frequency, analyses performed, and other aspects of monitoring network design can have major implications for detecting releases and for making subsequent higher level decisions about facility operation and remediation. The Integrated Environmental Monitoring (IEM) concept is a set of analytical procedures and software tools that can be used to improve monitoring network design decisions. Such decisions include the choice of monitoring locations, sampling frequencies, sensor technologies, and monitored constituents. IEM provides a set of monitoring alternatives that balance the tradeoffs between competing monitoring objectives such as the minimization of cost and the minimization of uncertainty. The alternatives provided are the best available with respect to the monitoring objectives, consistent with the physical and chemical characteristics of the site, and consist with applicable regulatory requirements. The selection of the best monitoring alternative to implement is made by the stakeholders after reviewing the alternatives and tradeoffs produced by the IEM process

  14. Islay LIMPET project monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Heath, T.

    2002-07-01

    Wavegen was contracted by the DTI as part of its Sustainable Energy Programmes to monitor and report on the final stages of the construction, installation of turbo-generation equipment, commissioning and operation of the LIMPET wave energy system. The report discusses the choice of technology, where the system was installed, power take off, construction of the collector, installation of the turbo-generator, maintenance, operation, management and planning issues. The performance of the system was found to be poorer than expected and the reasons for this were identified. The main conclusions were that the system is sufficiently robust to operate in the marine environment and downtimes are expected to be short.

  15. Mitigation Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    1992-09-01

    The Final Supplemental Environmental Impact Report (SEIR) (September 1992) for the Proposed Renewal of the Contract between the United States Department of Energy and The Regents of the University of California for the Operation and Management of the Lawrence Berkeley Laboratory identifies the environmental impacts associated with renewing the contract and specifies a series of measures designed to mitigate adverse impacts to the environment. This Mitigation Monitoring Plan describes the procedures the University will use to implement the mitigation measures adopted in connection with the approval of the Contract.

  16. Remote Reactor Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Adam [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dazeley, Steve [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dobie, Doug [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marleau, Peter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brennan, Jim [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gerling, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sumner, Matthew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sweany, Melinda [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-10-21

    The overall goal of the WATCHMAN project is to experimentally demonstrate the potential of water Cerenkov antineutrino detectors as a tool for remote monitoring of nuclear reactors. In particular, the project seeks to field a large prototype gadolinium-doped, water-based antineutrino detector to demonstrate sensitivity to a power reactor at ~10 kilometer standoff using a kiloton scale detector. The technology under development, when fully realized at large scale, could provide remote near-real-time information about reactor existence and operational status for small operating nuclear reactors out to distances of many hundreds of kilometers.

  17. NASA Lunar Impact Monitoring

    Science.gov (United States)

    Suggs, Robert M.; Moser, D. E.

    2015-01-01

    The MSFC lunar impact monitoring program began in 2006 in support of environment definition for the Constellation (return to Moon) program. Work continued by the Meteoroid Environment Office after Constellation cancellation. Over 330 impacts have been recorded. A paper published in Icarus reported on the first 5 years of observations and 126 calibrated flashes. Icarus: http://www.sciencedirect.com/science/article/pii/S0019103514002243; ArXiv: http://arxiv.org/abs/1404.6458 A NASA Technical Memorandum on flash locations is in press

  18. Fetal body movement monitoring.

    Science.gov (United States)

    Rayburn, W F

    1990-03-01

    Recording fetal activity serves as an indirect measure of central nervous system integrity and function. The coordination of whole body movement, which requires complex neurologic control, is likely similar to that of the newborn infant. Short-term observations of the fetus are best performed using real-time ultrasound imaging. Monitoring fetal motion has been shown to be clinically worthwhile in predicting impending death or compromise, especially when placental insufficiency is longstanding. The presence of a vigorous fetus is reassuring. Perceived inactivity requires a reassessment of any underlying antepartum complication and a more precise evaluation by fetal heart rate testing or real-time ultrasonography before delivery is contemplated.

  19. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  20. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  1. Monitoring laundry for fleas

    International Nuclear Information System (INIS)

    Cooper, T.L.; Goldin, E.M.; Warnock, R.V.

    1987-01-01

    The San Onofre Unit 3 nuclear plant experienced fuel cladding failures during its first fuel cycle. When primary systems were opened for maintenance and refueling, areas on site were contaminated with fleas - tiny, highly radioactive fuel fragments. While highly mobile, these fragments demonstrated an affinity to attach to some surfaces and clothing. This paper discusses the problems encountered in detecting fleas in the presence of residual activation and fission product contamination on laundered protective clothing. A novel approach to overcome those inherent problems is presented and a home-built laundry monitor utilizing off-the-shelf components is described

  2. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  3. Monitoring of nuclear accidents

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, J.; Camps, J.

    2010-07-01

    No matter how extensive the safety measures might be in and around nuclear sites, an incident can never be entirely ruled out. SCK-CEN is a specialist in radiological evaluations, in order to determine the impact of ionising radiation or a discharge of radionuclides on man and the environment. In August 2008, a team of SCK-CEN researchers participated in the radiological monitoring of the environment after an incident at the National Institute of Radio Elements (IRE) in Fleurus. SCK-CEN also conducted thyroid gland measurements in the population. The incident provided useful lessons on dealing with nuclear emergency situations.

  4. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  5. Monitored retrievable storage status

    International Nuclear Information System (INIS)

    Carlson, J.H.

    1985-01-01

    The Department of Energy (DOE) is preparing a proposal for Congressional consideration of the inclusion of a monitored retrievable storage (MRS) facility as part of the Federal Nuclear Waste Management System. The DOE plans to submit the proposal package to the Congress by January 15, 1986. The proposed preferred location of the MRS facility is the former Clinch River Breeder site in the state of Tennessee. If the Congress approves implementation of the MRS proposal, it is estimated that the facility could be licensed and operational in ten years

  6. Monitored retrievable storage design

    International Nuclear Information System (INIS)

    Woods, W.D.

    1985-01-01

    The Nuclear Waste Policy Act of 1982 (NWPA) established a national policy for the safe storage and disposal of spent nuclear fuel and high-level radioactive waste. The NWPA requires that DOE... ''submit a proposal to Congress on the need for and feasibility of one or more Monitored Retrievable Storage (MRS) Facilities''... In subsequent evaluations of the commercial nuclear waste management system, DOE has identified important advantages in providing an MRS Facility as an integral part of the total system. The integral MRS Facility serves as an independent, centralized spent nuclear fuel and high-level waste handling and packaging facility with a safe temporary storage capacity

  7. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1999-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use 1 of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them. (author)

  8. The Stockpile Monitor Program

    International Nuclear Information System (INIS)

    Buntain, G.A.; Fletcher, M.; Rabie, R.

    1994-07-01

    Recent political changes have led to drastic reductions in the number of nuclear warheads in stockpile, as well as increased expectations for warhead-service lives. In order to support and maintain a shrinking and aging nuclear stockpile, weapon scientists and engineers need detailed information describing the environments experienced by weapons in the field. Hence, the Stockpile Monitor Program was initiated in 1991 to develop a comprehensive and accurate database of temperature and humidity conditions experienced by nuclear warheads both in storage and on-alert

  9. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1997-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them

  10. Monitoring of tritium

    Science.gov (United States)

    Corbett, James A.; Meacham, Sterling A.

    1981-01-01

    The fluid from a breeder nuclear reactor, which may be the sodium cooling fluid or the helium reactor-cover-gas, or the helium coolant of a gas-cooled reactor passes over the portion of the enclosure of a gaseous discharge device which is permeable to hydrogen and its isotopes. The tritium diffused into the discharge device is radioactive producing beta rays which ionize the gas (argon) in the discharge device. The tritium is monitored by measuring the ionization current produced when the sodium phase and the gas phase of the hydrogen isotopes within the enclosure are in equilibrium.

  11. Cluster processing business level monitor

    International Nuclear Information System (INIS)

    Muniz, Francisco J.

    2017-01-01

    This article describes a Cluster Processing Monitor. Several applications with this functionality can be freely found doing a search in the Google machine. However, those applications may offer more features that are needed on the Processing Monitor being proposed. Therefore, making the monitor output evaluation difficult to be understood by the user, at-a-glance. In addition, such monitors may add unnecessary processing cost to the Cluster. For these reasons, a completely new Cluster Processing Monitor module was designed and implemented. In the CDTN, Clusters are broadly used, mainly, in deterministic methods (CFD) and non-deterministic methods (Monte Carlo). (author)

  12. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  13. Cluster processing business level monitor

    Energy Technology Data Exchange (ETDEWEB)

    Muniz, Francisco J., E-mail: muniz@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    This article describes a Cluster Processing Monitor. Several applications with this functionality can be freely found doing a search in the Google machine. However, those applications may offer more features that are needed on the Processing Monitor being proposed. Therefore, making the monitor output evaluation difficult to be understood by the user, at-a-glance. In addition, such monitors may add unnecessary processing cost to the Cluster. For these reasons, a completely new Cluster Processing Monitor module was designed and implemented. In the CDTN, Clusters are broadly used, mainly, in deterministic methods (CFD) and non-deterministic methods (Monte Carlo). (author)

  14. Routine Radiological Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Bechtel Nevada

    1998-01-01

    The U.S. Department of Energy manages the Nevada Test Site in a manner that meets evolving DOE Missions and responds to the concerns of affected and interested individuals and agencies. This Routine Radiological Monitoring Plan addressess complicance with DOE Orders 5400.1 and 5400.5 and other drivers requiring routine effluent monitoring and environmental surveillance on the Nevada Test Site. This monitoring plan, prepared in 1998, addresses the activities conducted onsite NTS under the Final Environmental Impact Statement and Record of Decision. This radiological monitoring plan, prepared on behalf of the Nevada Test Site Landlord, brings together sitewide environmental surveillance; site-specific effluent monitoring; and operational monitoring conducted by various missions, programs, and projects on the NTS. The plan provides an approach to identifying and conducting routine radiological monitoring at the NTS, based on integrated technical, scientific, and regulatory complicance data needs

  15. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  16. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  17. Monitoring underground movements

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    On 16 September 2015 at 22:54:33 (UTC), an 8.3-magnitude earthquake struck off the coast of Chile. 11,650 km away, at CERN, a new-generation instrument – the Precision Laser Inclinometer (PLI) – recorded the extreme event. The PLI is being tested by a JINR/CERN/ATLAS team to measure the movements of underground structures and detectors.   The Precision Laser Inclinometer during assembly. The instrument has proven very accurate when taking measurements of the movements of underground structures at CERN.    The Precision Laser Inclinometer is an extremely sensitive device capable of monitoring ground angular oscillations in a frequency range of 0.001-1 Hz with a precision of 10-10 rad/Hz1/2. The instrument is currently installed in one of the old ISR transfer tunnels (TT1) built in 1970. However, its final destination could be the ATLAS cavern, where it would measure and monitor the fine movements of the underground structures, which can affect the precise posi...

  18. 1985 environmental monitoring report

    Energy Technology Data Exchange (ETDEWEB)

    Day, L.E.; Miltenberger, R.P.; Naidu, J.R. (eds.)

    1986-04-01

    The environmental monitoring program is designed to determine that BNL facilities operate such that the applicable environmental standards and effluent control requirements have been met. The data were evaluated using the appropriate environmental regulatory criteria. The environmental levels of radioactivity and other pollutants found in the vicinity of BNL during 1985 are summarized in this report. Detailed data are not included in the main body of the report, but are tabulated and presented in Appendix D. The environmental data include external radiation levels; radioactive air particulates; tritium concentrations; the amounts and concentrations of radioactivity in and the water quality of the stream into which liquid effluents are released; the water quality of the potable supply wells; the concentrations of radioactivity in biota from the stream; the concentrations of radioactivity in and the water quality of ground waters underlying the Laboratoy; concentrations of radioactivity in milk samples obtained in the vicinity of the Laboratory; and the 1984 strontium-90 data which was not available for inclusion in the 1984 Environmental Monitoring Report. In 1985, the results of the surveillance program demonstraed that the Laboratory has operated within the applicable environmental standards.

  19. Monitoring every last trace

    CERN Multimedia

    CERN Bulletin

    2014-01-01

    The LHC is set to reach a record energy of 6.5 TeV per beam next year and will therefore be producing high energy radiation, as will the injectors supplying it. When exposed to this radiation, some equipment could potentially become radioactive and must therefore be carefully identified and monitored... this is where TREC comes in: software developed by CERN and currently being deployed in our accelerators.   If it becomes slightly radioactive, some of the equipment that makes up CERN’s accelerators may potentially become a hazard to the people who handle or work near it. Even though the risk is usually very low, CERN is obliged to record the location of this equipment, identify it and deal with it in an appropriate manner. During LS1 for example, almost 30,000 radiation protection checks were carried out on more than 2,500 tonnes of equipment! In 2009, going one step further in monitoring this equipment and making the Laboratory even safer, Luca Bruno, then the Radiation Safety Of...

  20. Zebra mussel monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hennagir, T.

    1994-01-01

    In less than a decade, zebra mussels have become the latest environmental scourge to plague the North American power industry. Infestations in the Great Lakes region have already reached natural disaster proportions. The invasion shows little sign of subsiding; Michigan's inland waters are the next most likely threatened area. In the southern United States, the mussles' migration has extended about 50 miles deeper than experts had originally predicted. By the year 2000, zebra mussel monitoring and control efforts will cost business and industry $5 billion, according to the federal Aquatic Nuisance Prevention and Control Act of 1990. Estimates of more than $1 million to control mussel fouling are projected for the Great Lakes area alone. While small independent hydropower stations are not as susceptible to zebra mussles as coal or nuclear facilities, there is cause for concern. Infestations can quickly foul hydropower plant components, hampering equipment operation and reducing facility efficiency. In extreme cases, leaving the mussels unchecked can result in stoplog gate flow blockage or false water level gauge readings. Advance prevention is often an effective first-line of defense against this troublesome, rapidly spreading and extremely prolific mollusk. Mussel monitoring efforts should begin a year in advance of when zebra mussels are expected to appear in a given location. Hydropower facility components that come into contact or rely exclusively on raw water are at greatest risk, as are other external components such as embayment walls, screens, trashracks and fish ladders.

  1. Quantitative performance monitoring

    International Nuclear Information System (INIS)

    Heller, A.S.

    1987-01-01

    In the recently published update of NUREG/CR 3883, it was shown that Japanese plants of size and design similar to those in the US have significantly fewer trips in a given year of operation. One way to reduce such imbalance is the efficient use of available plant data. Since plant data are recorded and monitored continuously for management feedback and timely resolution of problems, this data should be actively used to increase the efficiency of operations and, ultimately, for a reduction of plant trips in power plants. A great deal of information is lost, however, if the analytical tools available for the data evaluation are misapplied or not adopted at all. This paper deals with a program developed to use quantitative techniques to monitor personnel performance in an operating power plant. Visual comparisons of ongoing performance with predetermined quantitative performance goals are made. A continuous feedback is provided to management for early detection of adverse trends and timely resolution of problems. Ultimately, costs are reduced through effective resource management and timely decision making

  2. Quo vadis, personnel monitoring

    International Nuclear Information System (INIS)

    Becker, K.

    1975-01-01

    With the increasing use of nuclear power and radiation sources, the selection of optimum systems for personnel monitoring is becoming a matter of worldwide concern. The present status of personnel dosimetry, sometimes characterized by unstable and inaccurate detectors and oversimplified interpretation of the results, leaves much to be desired. In particular, photographic film, although having certain advantages with regard to economics and information content, undergoes rapid changes in warm and humid climates. Careful sealing reduces, but does not prevent, these problems. The replacement of film by solid-state dosimeters, primarily thermoluminescence dosimeters, is in progress or being considered by an increasing number of institutions and requires a number of decisions concerning the choice of the optimum detector(s), badge design, and evaluation system; organizational matters, such as the desirability of automation and computerized bookkeeping; etc. The change also implies the potential use of such advanced concepts as different detectors and monitoring periods for the large number of low-risk persons and the small number of high-risk radiation workers. (auth)

  3. Monitoring the digital divide

    International Nuclear Information System (INIS)

    Canessa, E.; Cerdeira, H.A.; Matthews, W.; Cottrell, R.L.

    2003-05-01

    It is increasingly important to support the large numbers of scientists working in remote areas and having low-bandwidth access to the Internet. This will continue to be the case for years to come since there is evidence from PingER performance measurements that the, so-called, digital divide is not decreasing. In this work, we review the collaborative work of The Abdus Salam International Center for Theoretical Physics (ICTP) in Trieste - a leading organization promoting science dissemination in the developing world- and SLAC in Stanford, to monitor by PingER, Universities and Research Institutions all over the developing world following the recent 'Recommendations of Trieste' to help bridge the digital divide. As a result, PingER's deployment now covers the real-time monitoring of worldwide Internet performance and, in particular, West and Central Africa for the first time. We report on the results from the ICTP sites and quantitatively identify regions with poor performance, identify trends, discuss experiences and future work. (author)

  4. Modular Software Performance Monitoring

    CERN Document Server

    Kruse, D F

    2011-01-01

    CPU clock frequency is not likely to be increased significantly in the coming years, and data analysis speed can be improved by using more processors or buying new machines, only if one is willing to change the paradigm to a parallel one. Therefore, performance monitoring procedures and tools are needed to help programmers to optimize existing software running on current and future hardware. Low level information from hardware performance counters is vital to spot specific performance problems slowing program execution. HEP software is often huge and complex, and existing tools are unable to give results with the required granularity. We will report on the approach we have chose to solve this problem that involves decomposing the application into parts and monitoring each of them separately. Both counting and sampling methods are used to allow an analysis with the required custom granularity: from global level, up to the function level. A set of tools (based on perfmon2 – a software interface to hardware co...

  5. Monitoring the Digital Divide

    International Nuclear Information System (INIS)

    Cottrell, Les

    2003-01-01

    It is increasingly important to support the large numbers of scientists working in remote areas and having low bandwidth access to the Internet. This will continue to be the case for years to come since there is evidence from PingER performance measurements that the, so-called, digital divide is not decreasing. In this work, we review the collaborative work of The Abdus Salam International Center for Theoretical Physics (ICTP) in Trieste, a leading organization promoting science dissemination in the developing world- and SLAC in Stanford, to monitor by PingER, Universities and Research Institutions all over the developing world following the recent ''Recommendations of Trieste'' to help bridge the digital divide. As a result, PingER's deployment now covers the real-time monitoring of worldwide Internet performance and, in particular, West and Central Africa for the first time. We report on the results from the ICTP sites and quantitatively identify regions with poor performance, identify trends, discuss experiences and future work

  6. Monitoring Outpatient Care

    Science.gov (United States)

    2003-01-01

    Each year, health care costs for managing chronically ill patients increase as the life expectancy of Americans continues to grow. To handle this situation, many hospitals, doctors practices, and home care providers are turning to disease management, a system of coordinated health care interventions and communications, to improve outpatient care. By participating in daily monitoring programs, patients with congestive heart failure, chronic obstructive pulmonary disease, diabetes, and other chronic conditions requiring significant self-care are facing fewer emergency situations and hospitalizations. Cybernet Medical, a division of Ann Arbor, Michigan-based Cybernet Systems Corporation, is using the latest communications technology to augment the ways health care professionals monitor and assess patients with chronic diseases, while at the same time simplifying the patients interaction with technology. Cybernet s newest commercial product for this purpose evolved from research funded by NASA, the National Institute of Mental Health, and the Advanced Research Projects Agency. The research focused on the physiological assessment of astronauts and soldiers, human performance evaluation, and human-computer interaction. Cybernet Medical's MedStar Disease Management Data Collection System is an affordable, widely deployable solution for improving in-home-patient chronic disease management. The system's battery-powered and portable interface device collects physiological data from off-the-shelf instruments.

  7. HEMOSTASIOLOGICAL MONITORING DURING PREGNANCY

    Directory of Open Access Journals (Sweden)

    I. V. Medyannikova

    2014-01-01

    Full Text Available As gestation progresses, all hemostatic components show changes aimed at compensating for the expenditures associated with fetal development. Activation of the hemostatic system during pregnancy creates a premorbid background for thrombotic and hemorrhagic complications. Hemostasiological examination is one of the compulsory dispensary management stages for pregnant women. An algorithm for the diagnosis of pregnancy-associated disorders in the hemostatic system is to solve the following problems: to identify the causes of hemocoagulation disorders, to determine the risk of thrombotic and hemorrhagic disorders, to prevent obstetric complications, and to monitor antithrombotic therapy. Hemostatic monitoring in pregnant women is based on rating and special methods and includes 3 stages: early, extended, and differential.The need for extended hemostatic examination is first determined and the direction of a search for a defective component is concretized in relation of the changes found. Interpretation of laboratory test values in terms of a female medical history and gestational age underlies the timely diagnosis, adequate treatment policy, and effective prevention of gestational complications.

  8. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  9. Methane monitoring from space

    Science.gov (United States)

    Stephan, C.; Alpers, M.; Millet, B.; Ehret, G.; Flamant, P.

    2017-11-01

    Methane is one of the strongest anthropogenic greenhouse gases. It contributes by its radiative forcing significantly to the global warming. For a better understanding of climate changes, it is necessary to apply precise space-based measurement techniques in order to obtain a global view on the complex processes that control the methane concentration in the atmosphere. The MERLIN mission is a joint French-German cooperation, on a micro satellite mission for space-based measurement of spatial and temporal gradients of atmospheric methane columns on a global scale. MERLIN will be the first Integrated Path Differential Absorption LIDAR for greenhouse gas monitoring from space. In contrast to passive methane missions, the LIDAR instrument allows measurements at alllatitudes, all-seasons and during night.

  10. Monitor de Control Integral

    OpenAIRE

    García Corominas, Estefania

    2016-01-01

    Control Integral es un programa informático especializado en gestión de ferreterías, bricolaje, suministros industriales y centros de construcción. Este programa está formado por dos ejecutables: el primero de ellos es el de ‘Gestión' y el segundo es el llamado ‘Monitor'. El módulo de gestión se compone de diferentes características para satisfacer las necesidades de los clientes, actualización automática de precios de los artículos, terminal punto de venta (TPV) este permite la creación e im...

  11. Optical wear monitoring

    Science.gov (United States)

    Kidane, Getnet S; Desilva, Upul P.; He, Chengli; Ulerich, Nancy H.

    2016-07-26

    A gas turbine includes first and second parts having outer surfaces located adjacent to each other to create an interface where wear occurs. A wear probe is provided for monitoring wear of the outer surface of the first part, and includes an optical guide having first and second ends, wherein the first end is configured to be located flush with the outer surface of the first part. A fiber bundle includes first and second ends, the first end being located proximate to the second end of the optical guide. The fiber bundle includes a transmit fiber bundle comprising a first plurality of optical fibers coupled to a light source, and a receive fiber bundle coupled to a light detector and configured to detect reflected light. A processor is configured to determine a length of the optical guide based on the detected reflected light.

  12. Environmental monitoring report, 1975

    International Nuclear Information System (INIS)

    1976-01-01

    The Pinellas Plant is operated for the U. S. Energy Research and Development Administration (ERDA) by the Neutron Devices Department of the General Electric Company. The plant's 1100 employees are engaged in the design, development, and manufacture of special electronic and mechanical nuclear weapons components. The effluent and environmental monitoring programs maintained by the Pinellas Plant are designed to determine the efficiencies of treatment and control mechanisms, to provide measurements of discharge concentrations for comparison with applicable standards, and to assess the effect of these discharges on the environment. Small quantities of tritium gas, tritium oxide, and krypton-85 gas were released from the plant during the year. Average ground level concentrations of these radioisotopes were all significantly less than 1/10 of 1 percent of the recommended guide for continuous nonoccupational exposure

  13. Environmental Monitoring at ANSTO

    International Nuclear Information System (INIS)

    Ferris, J.; Harries, J.; Harrison, J.; Hoffmann, E.

    2003-01-01

    The Australian Nuclear Science and Technology Organisation (ANSTO) operates several national facilities, including Australia's only research reactor, HIFAR, produces radioisotopes and radiopharmaceuticals and carries out research in nuclear science and technology. ANSTO monitors the amount of airborne emissions, the radioactive and non-radioactive contaminants released to the sewer, the quality of storm water leaving the site and the quality of ground water. The potential effective dose rates to the general public from airborne discharges and effluent release from the Lucas Heights in 2002-03 were less than 0.006 mSv/year, well below the 1mSv/year dose rate limit for long term exposure that is recommended by the Australian National Occupational Health and Safety Commission

  14. Spacecraft Charge Monitor

    Science.gov (United States)

    Goembel, L.

    2003-12-01

    We are currently developing a flight prototype Spacecraft Charge Monitor (SCM) with support from NASA's Small Business Innovation Research (SBIR) program. The device will use a recently proposed high energy-resolution electron spectroscopic technique to determine spacecraft floating potential. The inspiration for the technique came from data collected by the Atmosphere Explorer (AE) satellites in the 1970s. The data available from the AE satellites indicate that the SCM may be able to determine spacecraft floating potential to within 0.1 V under certain conditions. Such accurate measurement of spacecraft charge could be used to correct biases in space plasma measurements. The device may also be able to measure spacecraft floating potential in the solar wind and in orbit around other planets.

  15. CNGS Muon Monitors

    CERN Document Server

    Marsili, A; Ferioli, G; Gschwendtner, E; Holzer, E B; Kramer, Daniel; CERN. Geneva. AB Department

    2008-01-01

    The CERN Neutrinos to Gran Sasso (CNGS) beam facility uses two muon detector stations as on-line feed back for the quality control of the neutrino beam. The muon detector stations are assembled in a cross-shaped array to provide the muon intensity and the vertical and horizontal muon profiles. Each station is equipped with 42 ionisation chambers, which are originally designed as Beam Loss Monitors (BLMs) for the Large Hadron Collider(LHC). The response of the muon detectors during the CNGS run 2007 and possible reasons for a non-linear behaviour with respect to the beam intensity are discussed. Results of the CNGS run 2008 are shown: The modifications done during the shutdown 2007/08 were successful and resulted in the expected linear behaviour of the muon detector response.

  16. Reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hiroto.

    1990-01-01

    The present invention concerns a reactor noise monitoring device by detecting abnormal sounds in background noises. Vibration sounds detected by accelerometers are applied to a loose parts detector. The detector generates high alarm if there are sudden impact sounds in the background noises and applies output signals to an accumulation device. If there is slight impact sounds in the vicinity of any of the accelerometers, the accumulation device accumulates the abnormal sounds assumed to be generated from an identical site while synchronizing the waveforms for all of the channels. Then, the device outputs signals in which the background noises are cancelled, as detection signals. Therefore, S/N ratio can be improved and the abnormal sounds contained in the background noises can be detected, to thereby improve the accuracy for estimating the position where the abnormal sounds are generated. (I.S.)

  17. Quantities for environmental monitoring

    International Nuclear Information System (INIS)

    1989-01-01

    It is recommended that if measurements are made with the objective of monitor radiation levels in the environment to elucidate long-term changes in these levels, then air kerma should be used. If the objective is to give an indication that levels from man-made sources are acceptable within specified limits for the exposure of people, then ambient dose equivalent should be used. It should be noted that radiation risks to individuals are best expressed by the quantity effective dose equivalent. If this latter quantity is to be accurately assessed, it may be necessary to obtain details of the quality of the environmental radiation that cannot be described adequately by simple measurements of either air kerma or ambient dose equivalent. If the above objectives pertain, the measurements should record both air kerma and ambient dose equivalent. If neutrons are measured in the environment then ambient dose equivalent is the appropriate quantity for both the above objectives. (author)

  18. Cylinder monitoring program

    Energy Technology Data Exchange (ETDEWEB)

    Alderson, J.H. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Cylinders containing depleted uranium hexafluoride (UF{sub 6}) in storage at the Department of Energy (DOE) gaseous diffusion plants, managed by Martin Marietta Energy Systems, Inc., are being evaluated to determine their expected storage life. Cylinders evaluated recently have been in storage service for 30 to 40 years. In the present environment, the remaining life for these storage cylinders is estimated to be 30 years or greater. The group of cylinders involved in recent tests will continue to be monitored on a periodic basis, and other storage cylinders will be observed as on a statistical sample population. The program has been extended to all types of large capacity UF{sub 6} cylinders.

  19. Monitored background radiometer

    International Nuclear Information System (INIS)

    Ruel, C.

    1988-01-01

    A monitored background radiometer is described comprising: a thermally conductive housing; low conductivity support means mounted on the housing; a sensing plate mounted on the low conductivity support means and spaced from the housing so as to be thermally insulated from the housing and having an outwardly facing first surface; the sensing plate being disposed relative to the housing to receive direct electromagnetic radiation from sources exterior to the radiometer upon the first surface only; means for controllably heating the sensing plate; first temperature sensitive means to measure the temperature of the housing; and second temperature sensitive means to measure the temperature of the sensing plate, so that the heat flux at the sensing plate may be determined from the temperatures of the housing and sensing plate after calibration of the radiometer by measuring the temperatures of the housing and sensing plate while controllably heating the sensing plate

  20. National Biological Monitoring Inventory

    International Nuclear Information System (INIS)

    Burgess, R.L.

    1979-01-01

    The National Biological Monitoring Inventory, initiated in 1975, currently consists of four computerized data bases and voluminous manual files. MAIN BIOMON contains detailed information on 1,021 projects, while MINI BIOMON provides skeletal data for over 3,000 projects in the 50 states, Puerto Rico, the Virgin Islands, plus a few in Canada and Mexico. BIBLIO BIOMON and DIRECTORY BIOMON complete the computerized data bases. The structure of the system provides for on-line search capabilities to generate details of agency sponsorship, indications of funding levels, taxonomic and geographic coverage, length of program life, managerial focus or emphasis, and condition of the data. Examples of each of these are discussed and illustrated, and potential use of the Inventory in a variety of situations is emphasized

  1. Miniaturized Environmental Monitoring Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    C. B. Freidhoff

    1997-09-01

    The objective of the Mass Spectrograph on a Chip (MSOC) program is the development of a miniature, multi-species gas sensor fabricated using silicon micromachining technology which will be orders of magnitude smaller and lower power consumption than a conventional mass spectrometer. The sensing and discrimination of this gas sensor are based on an ionic mass spectrograph, using magnetic and/or electrostatic fields. The fields cause a spatial separation of the ions according to their respective mass-to-charge ratio. The fabrication of this device involves the combination of microelectronics with micromechanically built sensors and, ultimately, vacuum pumps. The prototype of a chemical sensor would revolutionize the method of performing environmental monitoring for both commercial and government applications. The portable unit decided upon was the miniaturized gas chromatograph with a mass spectrometer detector, referred to as a GC/MS in the analytical marketplace.

  2. Monitor update: 1979

    International Nuclear Information System (INIS)

    Grisham, D.L.; Ekberg, E.L.; Lambert, J.E.; Meyer, R.E.; Stroik, P.J.; Wickham, M.D.

    1980-01-01

    The Clinton P. Anderson Meson Physics Facility (LAMPF) has developed an advanced remote-handling system (Monitor) that is routinely used to perform complex tasks required to maintain, replace, and improve highly radioactive experimental facilities and components. This advanced system is based on the use of first-generation, force-reflecting servomanipulators that are placed at the remote-task site by a commercial hydraulic crane. A number of television cameras provide the viewing for the operations. Although LAMPF is now able to perform all the maintenance necessary on our main experimental beam line, advancements in manipulator dexterity and capacity, television viewing, and master-slave control links are required to develop the speed and dexterity necessary for general use. These developments should be undertaken as soon as possible to provide a means of routine handling of toxic and dangerous materials, as well as a capability to respond to disasters

  3. Environmental monitoring report, 1974

    International Nuclear Information System (INIS)

    1975-01-01

    Results are reported of the effluent and environmental monitoring programs at the Pinellas Plant during 1974. Sample analyses revealed the on-site sewage treatment facility operated well within State of Florida Standards. Likewise, offsite discharges met the applicable standards for arsenic, biochemical oxygen demand, chlorides, chromium, copper, cyanides, detergents, dissolved oxygen, dissolved solids, fluorides, lead, mercury, nitrogen, oils and greases, phenols, pH, phosphorus, suspended solids, turbidity and zinc. The results of iron and specific conductance analyses showed levels in excess of state standards and are discussed in the body of the report. In addition to the non-radioactive parameters listed above, a small quantity of radioactive tritium oxide was released in the plant's liquid effluent. Small quantities of tritium gas, tritium oxide, and krypton-85 gas were released from the plant during the year. Average ground level concentrations of these radioisotopes were all significantly less than 1 percent of recommended guide for continuous nonoccupational exposure. (U.S.)

  4. Correlation monitor materials

    International Nuclear Information System (INIS)

    Corwin, W.R.

    1995-01-01

    This task has been established with the explicit purpose of ensuring the continued availability of the pedigreed and extremely well-characterized material now required for inclusion in all additional and future surveillance capsules in commercial light-water reactors. During this reporting period, concrete was poured and pallets storage racks were installed to provide adequate room for the storage of the correlation monitor material being transferred from its location at the Y-12 Plant to its archival storage location at ORNL. The racks came from surplus material storage at ORNL and hence were obtained at no cost to the HSSI Program. Inquiries into cost-effective means of sheltering the blocks of correlation monitor materials from further weather-related deteriorization were initiated. The most likely approach would be to procure a turn-key sheet metal building installed over the storage racks by an outside contractor to minimize costs. Most of the material has now been transferred from Y-12 to the ORNL storage area. It has been repositioned on new storage pallets and placed into the storage racks, An update of the detailed material inventory was initiated to ascertain the revised location of all blocks. Pieces of HSST plate O3 were distributed to participants in the ASTM cross-comparison exercise on subsize specimen testing technology. The use of the HSST O3 will provide for data from the many varieties of tests to be performed to be compared with the standardized data previously developed. The testing techniques will focus on ways to measure transition temperature and fracture toughness

  5. Arctic Terrestrial Biodiversity Monitoring Plan

    DEFF Research Database (Denmark)

    Christensen, Tom; Payne, J.; Doyle, M.

    The Conservation of Arctic Flora and Fauna (CAFF), the biodiversity working group of the Arctic Council, established the Circumpolar Biodiversity Monitoring Program (CBMP) to address the need for coordinated and standardized monitoring of Arctic environments. The CBMP includes an international...... on developing and implementing long-term plans for monitoring the integrity of Arctic biomes: terrestrial, marine, freshwater, and coastal (under development) environments. The CBMP Terrestrial Expert Monitoring Group (CBMP-TEMG) has developed the Arctic Terrestrial Biodiversity Monitoring Plan (CBMP......-Terrestrial Plan/the Plan) as the framework for coordinated, long-term Arctic terrestrial biodiversity monitoring. The goal of the CBMP-Terrestrial Plan is to improve the collective ability of Arctic traditional knowledge (TK) holders, northern communities, and scientists to detect, understand and report on long...

  6. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  7. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Hartman, Mary J.; Dresel, P. Evan; Lindberg, Jon W.; Newcomer, Darrell R.; Thornton, Edward C.

    2000-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954; the Resource Conservation and Recovery Act of 1976; the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The U.S. Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/ frequency matrix for the entire site. The objectives of monitoring fall into three general categories: plume and trend tracking, treatment/ storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  8. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Newcomer, D.R.; Thornton, E.C.; Hartman, M.J.; Dresel, P.E.

    1999-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954 the Resource Conservation and Recovery Act of 1976 the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The US Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/frequency matrix for the entire site. The objectives of monitoring fall into three general categories plume and trend tracking, treatment/storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  9. MODERN ASPECTS OF BRIDGES MONITORING

    Directory of Open Access Journals (Sweden)

    M. I. Kazakevych

    2007-12-01

    Full Text Available The major concepts of the elaboration and realization of the bridge construction monitoring systemic approach are presented in this paper. The main peculiarity of the bridge monitoring modern aspect is pointed out here, namely, the transition from the demands of providing the reliability to the demands of providing the whole complex of the structure consumer qualities. The criteria of diagnostics of the bridge exploitation reliability as the fundamental aim of monitoring are formulated here.

  10. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  11. Wind turbine control and monitoring

    CERN Document Server

    Luo, Ningsu; Acho, Leonardo

    2014-01-01

    Maximizing reader insights into the latest technical developments and trends involving wind turbine control and monitoring, fault diagnosis, and wind power systems, 'Wind Turbine Control and Monitoring' presents an accessible and straightforward introduction to wind turbines, but also includes an in-depth analysis incorporating illustrations, tables and examples on how to use wind turbine modeling and simulation software.   Featuring analysis from leading experts and researchers in the field, the book provides new understanding, methodologies and algorithms of control and monitoring, comput

  12. High bandwidth beam current monitor

    International Nuclear Information System (INIS)

    Baltrusaitis, R.M.; Ekdahl, C.A.; Cooper, R.G.; Peterson, E.; Warn, C.E.

    1993-01-01

    A stripline directional coupler beam current monitor capable of measuring the time structure of a 30-ps electron beam bunch has been developed. The time response performance of the monitor compares very well with Cherenkov light produced in quartz by the electron beam. The four-pickup monitor is now used on a routine basis for measuring the beam duration, tuning for optimized beam bunching, and centering the bunch in the beam pipe

  13. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  14. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  15. Mound Plant Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Bauer, L.R.; Tullis, M.S.; Paulick, R.P.; Roush, L.L.

    1994-07-01

    The purpose of this Environmental Monitoring Plan (EMP) is to describe the environmental monitoring and surveillance programs in place at Mound. The Plan is required by DOE Order 5400.1 (DOE, 1990). The programs described in the EMP are required by the DOE 5400 Order series and by the Environmental Regulatory Guide for Radiological Effluent Monitoring and Environment Surveillance (DOE 1991a), referred to as the Regulatory Guide throughout this Plan

  16. 40 CFR 141.621 - Routine monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Routine monitoring. 141.621 Section....621 Routine monitoring. (a) Monitoring. (1) If you submitted an IDSE report, you must begin monitoring..., you must monitor at the location(s) and dates identified in your monitoring plan in § 141.132(f...

  17. 40 CFR 74.61 - Monitoring plan.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring plan. 74.61 Section 74.61... OPT-INS Monitoring Emissions: Combustion Sources § 74.61 Monitoring plan. (a) Monitoring plan. The... monitoring plan that includes the information required in a monitoring plan under § 75.53 of this chapter...

  18. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  19. Android Based Area Web Monitoring

    Science.gov (United States)

    Kanigoro, Bayu; Galih Salman, Afan; Moniaga, Jurike V.; Chandra, Eric; Rezky Chandra, Zein

    2014-03-01

    The research objective is to develop an application that can be used in the monitoring of an area by using a webcam. It aims to create a sense of security on the user's application because it can monitor an area using mobile phone anywhere. The results obtained in this study is to create an area with a webcam monitoring application that can be accessed anywhere as long as the monitoring results have internet access and can also be accessed through Android Based Mobile Phone.

  20. Android Based Area Web Monitoring

    Directory of Open Access Journals (Sweden)

    Kanigoro Bayu

    2014-03-01

    Full Text Available The research objective is to develop an application that can be used in the monitoring of an area by using a webcam. It aims to create a sense of security on the user's application because it can monitor an area using mobile phone anywhere. The results obtained in this study is to create an area with a webcam monitoring application that can be accessed anywhere as long as the monitoring results have internet access and can also be accessed through Android Based Mobile Phone.

  1. Implementation of the monitor concept

    Energy Technology Data Exchange (ETDEWEB)

    Gerstenberger, M.

    1982-01-01

    Sequential and parallel computer programs are contrasted, and the problems of implementing compilers are stated, with special reference to the Pascal language. Process and monitor data types in computer programming are described, various procedures are listed and the monitor concept is applied to a generator-user problem. A Pascal initiator program is listed. It is claimed that the monitor approach can yield lower fault levels than assembler or semaphore approaches. It is pointed out that monitors for program synchronisation are only applicable for common, and not for distributed, storage systems. 9 references.

  2. Enhanced safeguards via solution monitoring

    International Nuclear Information System (INIS)

    Burr, T.; Wangen, L.

    1996-09-01

    Solution monitoring is defined as the essentially continuous monitoring of solution level, density, and temperature in all tanks in the process that contain, or could contain, safeguards-significant quantities of nuclear material. This report describes some of the enhancements that solution monitoring could make to international safeguards. The focus is on the quantifiable benefits of solution monitoring, but qualitatively, solution monitoring can be viewed as a form of surveillance. Quantitatively, solution monitoring can in some cases improve diversion detection probability. For example, the authors show that under certain assumptions, solution monitoring can be used to reduce the standard deviation of the annual material balance, σ MB , from approximately 17 kg to approximately 4 kg. Such reduction in σ MB will not always be possible, as they discuss. However, in all cases, solution monitoring would provide assurance that the measurement error models are adequate so that one has confidence in his estimate of σ MB . Some of the results in this report were generated using data that were simulated with prototype solution monitoring software that they are developing. An accompanying document describes that software

  3. Atmospheric air contamination monitoring. Monitoring station ASS-500, GIG Katowice

    International Nuclear Information System (INIS)

    Michalik, B.

    1993-01-01

    The results obtained during the period of 1991-1993 in monitoring station ASS-500 working in Katowice have been presented. The concentration of 137 Cs, 226 Ra, 40 K, 7 Be and dustiness in atmospheric air have been shown. Some proposals about the modifications of monitoring station ASS-500 have been introduced. 3 figs, 5 tabs

  4. Ultrasonic wireless health monitoring

    Science.gov (United States)

    Petit, Lionel; Lefeuvre, Elie; Guyomar, Daniel; Richard, Claude; Guy, Philippe; Yuse, Kaori; Monnier, Thomas

    2006-03-01

    The integration of autonomous wireless elements in health monitoring network increases the reliability by suppressing power supplies and data transmission wiring. Micro-power piezoelectric generators are an attractive alternative to primary batteries which are limited by a finite amount of energy, a limited capacity retention and a short shelf life (few years). Our goal is to implement such an energy harvesting system for powering a single AWT (Autonomous Wireless Transmitter) using our SSH (Synchronized Switch Harvesting) method. Based on a non linear process of the piezoelement voltage, this SSH method optimizes the energy extraction from the mechanical vibrations. This AWT has two main functions : The generation of an identifier code by RF transmission to the central receiver and the Lamb wave generation for the health monitoring of the host structure. A damage index is derived from the variation between the transmitted wave spectrum and a reference spectrum. The same piezoelements are used for the energy harvesting function and the Lamb wave generation, thus reducing mass and cost. A micro-controller drives the energy balance and synchronizes the functions. Such an autonomous transmitter has been evaluated on a 300x50x2 mm 3 composite cantilever beam. Four 33x11x0.3 mm 3 piezoelements are used for the energy harvesting and for the wave lamb generation. A piezoelectric sensor is placed at the free end of the beam to track the transmitted Lamb wave. In this configuration, the needed energy for the RF emission is 0.1 mJ for a 1 byte-information and the Lamb wave emission requires less than 0.1mJ. The AWT can harvested an energy quantity of approximately 20 mJ (for a 1.5 Mpa lateral stress) with a 470 μF storage capacitor. This corresponds to a power density near to 6mW/cm 3. The experimental AWT energy abilities are presented and the damage detection process is discussed. Finally, some envisaged solutions are introduced for the implementation of the required data

  5. Permafrost Monitoring Sonnblick

    Science.gov (United States)

    Reisenhofer, Stefan; Riedl, Claudia

    2014-05-01

    Within the project 'Permafrost Monitoring Sonnblick' (PERSON) the spatial distribution of permafrost is investigated by the 'Zentralanstalt für Meteorologie und Geodynamik' (ZAMG) in the Sonnblick area, in the Hohe Tauern in Austria. The aim of PERSON is to identify parameters affecting permafrost (geological, geomorphological, orographical and climatic factors), to determine its spatio-temporal behaviour under present day climate conditions and to estimate its possible future extension under a climate change scenario. PERSON makes use of a permafrost monitoring network that was installed 2005 in the Sonnblick area and is made up by four study sites: On the one hand the spatial extension of permafrost was focused at the ice-dammed lake Pilatus and the rock glacier Zirmsee. On the other hand, at two sites, namely Goldbergspitze and Wintergasse measurements of 'Ground-Surface Temperature' (GST) and 'Bottom Temperatures of the Snow cover' (BTS) are measured. In order to record temperatures in the uppermost layer of the ground and avoid heating by direct solar radiation loggers were buried a few centimetres into the ground or installed in boreholes at depths between 2 and 140 cm. Each of the 'Near Surface Temperature' (NST) borehole mouths is closed up with insulating foam to protect the measurements from atmospheric influence. In addition to these measurements, continuous temperature records from three 20 m deep boreholes located at the southern slope of Hoher Sonnblick are available since 2007, which represent the longest series of its kind in Austria. Furthermore, data from seismic and geoelectric measurements, temperature sensors readings at the surface and extensive meteorological observations from the Sonnblick Observatory are available. Already collected and evaluated data indicate that the thickness of the debris layer around the boreholes reaches a depth of 2 m but no more. The active layer thickness measured in the borehole next to the glacier ranges between

  6. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Science.gov (United States)

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  7. Monitoring CSF proteome alterations in amyotrophic lateral sclerosis: obstacles and perspectives in translating a novel marker panel to the clinic.

    Directory of Open Access Journals (Sweden)

    Nils von Neuhoff

    Full Text Available BACKGROUND: Amyotrophic lateral sclerosis (ALS is a fatal disorder of the motor neuron system with poor prognosis and marginal therapeutic options. Current clinical diagnostic criteria are based on electrophysiological examination and exclusion of other ALS-mimicking conditions. Neuroprotective treatments are, however, most promising in early disease stages. Identification of disease-specific CSF biomarkers and associated biochemical pathways is therefore most relevant to monitor disease progression, response to neuroprotective agents and to enable early inclusion of patients into clinical trials. METHODS AND FINDINGS: CSF from 35 patients with ALS diagnosed according to the revised El Escorial criteria and 23 age-matched controls was processed using paramagnetic bead chromatography for protein isolation and subsequently analyzed by MALDI-TOF mass spectrometry. CSF protein profiles were integrated into a Random Forest model constructed from 153 mass peaks. After reducing this peak set to the top 25%, a classifier was built which enabled prediction of ALS with high accuracy, sensitivity and specificity. Further analysis of the identified peptides resulted in a panel of five highly sensitive ALS biomarkers. Upregulation of secreted phosphoprotein 1 in ALS-CSF samples was confirmed by univariate analysis of ELISA and mass spectrometry data. Further quantitative validation of the five biomarkers was achieved in an 80-plex Multiple Reaction Monitoring mass spectrometry assay. CONCLUSIONS: ALS classification based on the CSF biomarker panel proposed in this study could become a valuable predictive tool for early clinical risk stratification. Of the numerous CSF proteins identified, many have putative roles in ALS-related metabolic processes, particularly in chromogranin-mediated secretion signaling pathways. While a stand-alone clinical application of this classifier will only be possible after further validation and a multicenter trial, it could be

  8. Environmental Monitoring Plan, Revision 6

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, G M; Bertoldo, N A; Blake, R G; Campbell, C G; Grayson, A R; Nelson, J C; Revelli, M A; Rosene, C A; Wegrecki, T; Williams, R A; Wilson, K R; Jones, H E

    2012-03-02

    The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. Specifically, environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring is also a major component of compliance demonstration for permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality; (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work; and (3) An integrated sampling approach to avoid duplicative data collection. LLNL prepares the EMP because it provides an organizational framework for ensuring that environmental monitoring work, which is integral to the implementation of LLNL's Environmental Management System, is conducted appropriately. Furthermore, the Environmental Monitoring Plan helps LLNL ensure compliance with DOE Order 231.1 Change 2, Environment, Safety and Health Reporting

  9. Neutron flux monitor

    International Nuclear Information System (INIS)

    Oda, Naotaka.

    1993-01-01

    The device of the present invention greatly saves an analog processing section such as an analog filter and an analog processing circuit. That is, the device of the present invention comprises (1) a neutron flux detection means for detecting neutron fluxed in the reactor, (2) a digital filter means for dividing signals corresponding to the detected neutron fluxes into predetermined frequency band regions, (3) a calculation processing means for applying a calculation processing corresponding to the frequency band regions to the neutron flux detection signals divided by the digital filter means. With such a constitution, since the neutron detection signals are processed by the digital filter means, the accuracy is improved and the change for the property of the filter is facilitated. Further, when a neutron flux level is obtained, a calculation processing corresponding to the frequency band region can be conducted without the analog processing circuit. Accordingly, maintenance and accuracy are improved by greatly decreasing the number of parts. Further, since problems inherent to the analog circuit are solved, neutron fluxes are monitored at high reliability. (I.S.)

  10. Interactive Inventory Monitoring

    Science.gov (United States)

    Garud, Sumedha

    2013-01-01

    Method and system for monitoring present location and/or present status of a target inventory item, where the inventory items are located on one or more inventory shelves or other inventory receptacles that communicate with an inventory base station through use of responders such as RFIDs. A user operates a hand held interrogation and display (lAD) module that communicates with, or is part of the base station to provide an initial inquiry. lnformation on location(s) of the larget invenlory item is also indicated visibly and/or audibly on the receptacle(s) for the user. Status information includes an assessment of operation readiness and a time, if known, that the specified inventory item or class was last removed or examined or modified. Presentation of a user access level may be required for access to the target inventgory item. Another embodiment provides inventory informatin for a stack as a sight-impaired or hearing-impaired person adjacent to that stack.

  11. Airborne monitoring system

    International Nuclear Information System (INIS)

    Kadmon, Y.; Gabovitch, A.; Tirosh, D.; Ellenbogen, M.; Mazor, T.; Barak, D.

    1997-01-01

    A complete system for tracking, mapping, and performing a composition analysis of a radioactive plume and contaminated area was developed at the NRCN. The system includes two major units : An airborne unit for monitoring and a ground station for analyzing. The airborne unit is mounted on a helicopter and includes file following. Four radiation sensor, two 2'' x 2'' Nal (Tl) sensors horizontally separated by lead shield for mapping and spectroscopy, and two Geiger Mueller (GM) tubes as part of the safety system. A multichannel analyzer card is used for spectroscopy. A navigation system, based on GPS and a barometric altitude meter, is used to locate the plume or ground data. The telemetry system, consisting of a transceiver and a modem, transfers all the data in real time to the ground station. An industrial PC (Field Works) runs a dedicated C++ Windows application to manage the acquired data. An independent microprocessor based backup system includes a recorder, display, and key pad. The ground station is based on an industrial PC, a telemetry system, a color printer and a modem to communicate with automatic meteorology stations in the relevant area. A special software controls the ground station. Measurement results are analyzed in the ground station to estimate plume parameters including motion, location, size, velocity, and perform risk assessment. (authors)

  12. Infrared monitoring of combustion

    International Nuclear Information System (INIS)

    Bates, S.C.; Morrison, P.W. Jr.; Solomon, P.R.

    1991-01-01

    In this paper, the use of Fourier Transform Infrared (FT-IR) spectroscopy for combustion monitoring is described. A combination of emission, transmission, and reflection FT-IR spectroscopy yields data on the temperature and composition of the gases, surfaces and suspended particles in the combustion environment. Detection sensitivity of such trace exhaust gases as CO, CO 2 , SO 2 , NO x , and unburned hydrocarbons is at the ppm level. Tomographic reconstruction converts line-of-sight measurements into spatially resolved temperature and concentration data. Examples from various combustion processes are used to demonstrate the capabilities of the technique. Industrial measurements are described that have been performed directly in the combustion zone and in the exhaust duct of a large chemical recovery boiler. Other measurements of hot slag show how FT-IR spectroscopy can determine the temperature and optical properties of surfaces. In addition, experiments with water droplets show that transmission FT-IR data yield spectra that characterize particle size and number density

  13. Ultrasonic monitoring system

    International Nuclear Information System (INIS)

    McLain, R.E.

    1975-01-01

    The ultrasonic monitoring system is used in LMFBR's, BWR's or PWR's. A remotely controlled, movable instrument carrier may be used which contains the piezo-electric transducer and is connected to the main control console by a transmission cable. An excitation pulse coming from a pulse generator is used to excite the transducer with a maximum of energy, independent of the length of the transmission line. Pulse width and pulse amplitude can be set without any direct interference into the transducer. For this purpose, a resistor whose impedance has been matched to that of the transmission line is connected to the input of the transmission line. Moreover, a capacitor for generation of the excitation pulse is coupled with the transmission line by means of a four-layer switching diode and is discharged. For termination of the excitation and the control pulses, respectively, another four-layer switching diode connected parallel to the capacitor quickly discharges the capacitor. The capacitor and the capacitance of the line constitute a voltage divider. In this way it is possible to change the length of the transmission line and, to safeguard the generation of a pulse of the desired amplitude, only vary the capacitance of the capacitor. (DG/RF) [de

  14. Fatigue monitoring desktop guide

    International Nuclear Information System (INIS)

    Woods, K.; Thomas, K.

    2012-01-01

    The development of a program for managing material aging (MMG) in the nuclear industry requires a new and different perspective. The classical method for MMG is cycle counting, which has been shown to have limited success. The classical method has been successful in satisfying the ductile condition per the America Society of Mechanical Engineers' (ASME) design criteria. However, the defined material failure mechanism has transformed from through-wall cracking and leakage (ASME) to crack initiation (NUREG-6909). This transformation is based on current industry experience with material degradation early in plant life and can be attributed to fabrication issues and environment concerns where cycle counting has been unsuccessful. This new perspective provides a different approach to cycle counting that incorporates all of the information about the material conditions. This approach goes beyond the consideration of a static analysis and includes a dynamic assessment of component health, which is required for operating plants. This health definition should consider fabrication, inspections, transient conditions and industry operating experience. In addition, this collection of information can be transparent to a broader audience that may not have a full understanding of the system design or the potential causes of early material degradation. This paper will present the key points that are needed for a successful fatigue monitoring desktop guide. (authors)

  15. Plant monitor system

    International Nuclear Information System (INIS)

    Scarola, K.; Jamison, D.; Manazir, R.; Rescori, R.; Harmon, D.

    1991-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system which is nuclear qualified for rapid response to changes in plant parameters and a component control system which together provide a discrete monitoring and control capability at a panel in the control room. A separate data processing system, which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs and a large, overhead integrated process status overview board. The discrete indicator and alarm system and the data processing system receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the main machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof. (author)

  16. Plant monitoring device

    International Nuclear Information System (INIS)

    Ito, Toru.

    1994-01-01

    The device of the present invention comprises a data collecting section for periodically collecting processed data sent from plant equipments, a top node induction and processing section for an important plant function model for inducing the plant function to be noted particularly by an operator from important plant function models by using process data and a window screen selection section for selecting a window screen to be displayed based on the result of the evaluation for each of function nodes based on the processing described above and determining the layout and automatically forming the display screen. It is constituted so that the kind and the layout of the window under display are checked if they are the same as those one cycle before or not and, if they are different, the screen is automatically switched to a new screen display. Then, operator's psychological burdens such as selection of information and judgement for the operation upon occurrence of plant abnormality and accident can be mitigated, to provide a safe operation circumstance having reinforced monitoring of the function of the whole plant can be provided. (N.H.)

  17. Neutron flux monitoring device

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro.

    1995-01-01

    In a neutron flux monitoring device, there are disposed a neutron flux measuring means for outputting signals in accordance with the intensity of neutron fluxes, a calculation means for calculating a self power density spectrum at a frequency band suitable to an object to be measured based on the output of the neutron flux measuring means, an alarm set value generation means for outputting an alarm set value as a comparative reference, and an alarm judging means for comparing the alarm set value with the outputted value of the calculation means to judge requirement of generating an alarm and generate an alarm in accordance with the result of the judgement. Namely, the time-series of neutron flux signals is put to fourier transformation for a predetermined period of time by the calculation means, and from each of square sums for real number component and imaginary number component for each of the frequencies, a self power density spectrum in the frequency band suitable to the object to be measured is calculated. Then, when the set reference value is exceeded, an alarm is generated. This can reliably prevent generation of erroneous alarm due to neutron flux noises and can accurately generate an alarm at an appropriate time. (N.H.)

  18. Reactor power distribution monitor

    International Nuclear Information System (INIS)

    Sekimizu, Koichi

    1980-01-01

    Purpose: To improve the performance and secure the safety of a nuclear reactor by rapidly computing and display the power density in the nuclear reactor by using a plurality of processors. Constitution: Plant data for a nuclear reactor containing the measured values from a local power monitor LPRM are sent and recorded in a magnetic disc. They are also sent to a core performance computer in which burn-up degree distribution and the like are computed, and the results are sent and recorded in the magnetic disc. A central processors loads programs to each of the processors and applies data recorded in the magnetic disc to each of the processors. Each of the processors computes the corresponding power distribution in four fuel assemblies surrounding the LPRM string by the above information. The central processor compiles the computation results and displays them on a display. In this way, power distribution in the fuel assemblies can rapidly be computed to thereby secure the improvement of the performance and safety of the reactor. (Seki, T.)

  19. Atmospheric radiation monitor

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, M.A. Leigui de; Peixoto, C.J. Todero; Leao, M.S.A.B.; Luzio, V.P. [Universidade Federal do ABC (UFABC), SP (Brazil); Barbosa, A.F.; Lima Junior, H.P.; Vilar, A.B.; Gama, R.G.; Ferraz, V.A. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Full text: The Atmospheric Radiation Monitor (MonRAt) is a compact telescope designed to detect fluorescence photons generated in the atmosphere by ultra-high energy cosmic rays showers with energies in the interval between 10{sup 17} eV and 10{sup 18} eV. It is composite by a 64 pixels MultiAnodic PhotoMultiplier Tube (MAPMT) placed at the focus of a parabolic mirror mounted in a Newtonian telescope setup and the data acquisition system. In front of the MAPMT photocathode, filters will be positioned to select light with wavelength in the near ultraviolet region (300 nm < {lambda} < 450 nm) where the nitrogen fluorescent emissions occurs. The data acquisition system consists of a set of pre-amplifiers and FPGA-based boards able to record trigger times and waveforms from each channel and send the data to a computer by USB ports. MonRAt will be used to detect fluorescence photons under different atmospheric conditions (pressure, temperature, humidity, local geomagnetic field, etc) and will contribute with a detailed study of the fluorescence radiation yield. The assembly of the telescope is under way and we present in this work the status of the experiment and its first measurements in the laboratory. (author)

  20. Atmospheric radiation monitor

    International Nuclear Information System (INIS)

    Oliveira, M.A. Leigui de; Peixoto, C.J. Todero; Leao, M.S.A.B.; Luzio, V.P.; Barbosa, A.F.; Lima Junior, H.P.; Vilar, A.B.; Gama, R.G.; Ferraz, V.A.

    2011-01-01

    Full text: The Atmospheric Radiation Monitor (MonRAt) is a compact telescope designed to detect fluorescence photons generated in the atmosphere by ultra-high energy cosmic rays showers with energies in the interval between 10 17 eV and 10 18 eV. It is composite by a 64 pixels MultiAnodic PhotoMultiplier Tube (MAPMT) placed at the focus of a parabolic mirror mounted in a Newtonian telescope setup and the data acquisition system. In front of the MAPMT photocathode, filters will be positioned to select light with wavelength in the near ultraviolet region (300 nm < λ < 450 nm) where the nitrogen fluorescent emissions occurs. The data acquisition system consists of a set of pre-amplifiers and FPGA-based boards able to record trigger times and waveforms from each channel and send the data to a computer by USB ports. MonRAt will be used to detect fluorescence photons under different atmospheric conditions (pressure, temperature, humidity, local geomagnetic field, etc) and will contribute with a detailed study of the fluorescence radiation yield. The assembly of the telescope is under way and we present in this work the status of the experiment and its first measurements in the laboratory. (author)

  1. Mare Risk Analysis monitor

    International Nuclear Information System (INIS)

    Fuente Prieto, I.; Alonso, P.; Carretero Fernandino, J. A.

    2000-01-01

    The Nuclear Safety Council's requirement that Spanish power plants comply with the requirements of the Maintenance Rule associated with plant risk assessment during power operation, arising from the partial unavailability of systems due to the maintenance activities, has led to need for additional tools to facilitate compliance with said requirements. While the impact on risk produced by individual equipment unavailabilities can easily be evaluated, either qualitatively or quantitatively, the process becomes more complicated when un programmed unavailabilities simultaneously occur in various systems, making it necessary to evaluate their functional impact. It is especially complex in the case of support systems that can affect the functionality of multiple systems. In view of the above, a computer application has been developed that is capable of providing the operator with quick answers based on the specific plant model in order to allow fast risk assessment using the information compiled as part of the Probabilistic Safety Analysis. The paper describes the most important characteristics of this application and the basic design requirements of the MARE Risk Monitor. (Author)

  2. Traveling wave monitor

    International Nuclear Information System (INIS)

    Heus, H.; Heutenik, B.; Kroes, F.; Maaskant, A.; Sluyk, T.

    The signals of the monitors, by means of ''Prodlines,'' are first brought out of the radiation surroundings of the tunnel. These coaxial cables have a very low attenuation for 2856 Mc and they couple well thermally, thus originating the least possible phase differentials through thermal expansion. To remove the last tenths of millimeters, a calibration can then still be applied. Only after calibration does the relative measurement become absolute. The conversion electronics are located in the instrument boxes. Here the signals are first mixed to a lower frequency (10 Mc) from where it is easier to perform an amplitude-independent phase detection. To this effect, the signals are first ''limited,'' after which a phase detection can take place, independently of the amplitude (i.e., of the beam current). Subsequently, there is an amplification in the Lf amplifiers and 50 ohm driver steps. The signal can, even via long cables, be carried to an oscilloscope; it can also be sent via the video highway

  3. Beam Position Monitor Engineering

    International Nuclear Information System (INIS)

    Smith, Stephen R.

    1996-07-01

    The design of beam position monitors often involves challenging system design choices. Position transducers must be robust, accurate, and generate adequate position signal without unduly disturbing the beam. Electronics must be reliable and affordable, usually while meeting tough requirements on precision. accuracy, and dynamic range. These requirements may be difficult to achieve simultaneously, leading the designer into interesting opportunities for optimization or compromise. Some useful techniques and tools are shown. Both finite element analysis and analytic techniques will be used to investigate quasi-static aspects of electromagnetic fields such as the impedance of and the coupling of beam to striplines or buttons. Finite-element tools will be used to understand dynamic aspects of the electromagnetic fields of beams, such as wake-fields and transmission-line and cavity effects in vacuum-to-air feed through. Mathematical modeling of electrical signals through a processing chain will be demonstrated, in particular to illuminate areas where neither a pure time-domain nor a pure frequency-domain analysis is obviously advantageous. Emphasis will be on calculational techniques, in particular on using both time-domain and frequency domain approaches to the applicable parts of interesting problems

  4. Reactor operation monitor

    International Nuclear Information System (INIS)

    Sakagami, Masaharu.

    1982-01-01

    Purpose: To improve the working performance of a reactor by extending the range for the power conditioning due to the control rod operation and flow rate control. Constitution: The results of calculations for the power distribution and the burn-up degree distribution of the reactor core from a reactor performance computer that processes each of measuring signals in a nuclear power plant are used as the inputs for a computing device of the fuel rod power hysteresis to form the power hysteresis for each of the fuel rods up to the present time. The data are used as the inputs for the computing device of the fuel rod performance index, and the fuel rod performance index representing the critical values for the stresses in the fuel rod cladding tubes and the critical values for the duration of the stresses determined from the power hysteresis and the burn-up degree of the fuel rod are calculated for each of the fuel rods. Accordingly, the power conditioning can be carried out upon power-up in the reactor while monitoring the fuel rod performance index f(t) for each of the fuel assemblies, whereby the range for the power conditioning due to the control rod operation and the flow rate control can be extended relative to fuel assemblies in which f(t) is smaller than 1. (Yoshino, Y.)

  5. Fatigue monitoring desktop guide

    Energy Technology Data Exchange (ETDEWEB)

    Woods, K. [InnoTech Engineering Solutions, LLC (United States); Thomas, K. [Nebraska Public Power District (United States)

    2012-07-01

    The development of a program for managing material aging (MMG) in the nuclear industry requires a new and different perspective. The classical method for MMG is cycle counting, which has been shown to have limited success. The classical method has been successful in satisfying the ductile condition per the America Society of Mechanical Engineers' (ASME) design criteria. However, the defined material failure mechanism has transformed from through-wall cracking and leakage (ASME) to crack initiation (NUREG-6909). This transformation is based on current industry experience with material degradation early in plant life and can be attributed to fabrication issues and environment concerns where cycle counting has been unsuccessful. This new perspective provides a different approach to cycle counting that incorporates all of the information about the material conditions. This approach goes beyond the consideration of a static analysis and includes a dynamic assessment of component health, which is required for operating plants. This health definition should consider fabrication, inspections, transient conditions and industry operating experience. In addition, this collection of information can be transparent to a broader audience that may not have a full understanding of the system design or the potential causes of early material degradation. This paper will present the key points that are needed for a successful fatigue monitoring desktop guide. (authors)

  6. Combine mobile monitoring conception

    International Nuclear Information System (INIS)

    Stolyarevsky, I.; Ivanov, J.A.; Arkhipov, N.

    2001-01-01

    This work is a document of joint final report of the collaboration between CHESCIR and JAERI on the Subject-1 'A Study on the Measurements and Evaluation of External Dose after Nuclear Accident' of JCP-1 project 'A Study on the Assessment, Analysis and Verification of the Consequences of the accident at Chernobyl' in the framework of the Agreement between JAERI and RIA 'PRIPYAT' (since 1994, CHESCIR) for 1995-1999. The most substantial part of the collaboration was research with using mobile gamma survey system, that was developed in JAERI and equipped with GIS - navigator that was developed in CHESCIR. During collaboration the carbone survey on the network of roads covered most are contaminated by Chernobyl fallout in Ukraine, Belorussia and Russia. Routes of carbone survey, carried out by CHESCIR team together with JAERI and alone for the last 5 years are shown in a non-complete map. Length of all routes taking into considers double raids is longer than 18,000 km. Experimental and methodological experience of mobile monitoring that collected by both sides allows to make considerations and conclusions, which are available in this final report. (J.P.N.)

  7. Temelin safety monitor

    International Nuclear Information System (INIS)

    Mlady, O.

    2000-01-01

    Temelin NPP is a WWER-1000/320 two unit plant under construction, originally designed according to the standards of the former Soviet Union. After a series of reviews in the 80s, a decision was taken to upgrade the design of Temelin, including the supply of fuel and instrumentation and instrumentation and control system (I and C). Details on the current design and other related safety matters were presented to the nuclear community in a meeting organized by the IAEA in November 1994. Based upon recommendations of IAEA OSART missions, post TMI requirements and Temelin Risk Audit recommendations it was decided to perform a Probabilistic Safety Assessment within the Temelin PSA Project. The general purpose of this project was to perform systematic examination of the Temelin Unit 1 NPP for severe accident vulnerabilities by performance of a Level 1 and 2 PSA study. In addition to the completion of Temelin documented living PSA model, the decision was to develop and implement a PSA based software tool able to analyze real and scheduled plant conditions for determining the risk impact of plant configurations and on-line maintenance activities. This paper provides an overview of the key features of the Temelin Safety Monitor, describes its development activities and its current status and intended use at Temelin NPP for PSA applications. (author)

  8. HOTLink rack monitor

    International Nuclear Information System (INIS)

    Al R Franck et al.

    2001-01-01

    A remote data acquisition chassis, called a HOTLink Rack Monitor, HRM, has been developed for use in the Fermilab control system. This chassis provides for 64 analog input channels, 8 analog output channels, and 8 bytes of digital I/O. The interface to the host VMEbus crate is by way of a 320 MHz HOTLink serial connection to a PMC mezzanine module. With no processor intervention, all data sources in the remote chassis are read at 100 sec intervals, time stamped, and stored in a 2 MB circular buffer on the PMC module. In operation, the memory always contains the most recent 16 k samples of 10 kHz data from all 64 analog input channels. An expansion module that resides in the HRM chassis records snapshot data for 8 analog channels, each channel consisting of up to 16 k readings, digitized at rates up to 10 MHz. Snapshot data is also returned and stored in buffers on the PMC module. Because the HRM presents a memory-mapped interface to the host, it is independent of the operating system and may be used in any system that supports PMC mezzanine modules

  9. Wireless monitoring of highways

    Science.gov (United States)

    Bennett, Richard; Hayes-Gill, Barrie; Crowe, John A.; Armitage, Robert; Rodgers, Dale; Hendroff, Adrian

    1999-05-01

    Electronic hardware has been developed to telemetrically transmit temperature and strain measurements from within a public highway in the UK. These measurements provide an important health check for monitoring fatigue damage in pavements. Previous attempts at measuring strain and temperature have required lengths of cable to be installed in the highway. The installation of these cables is both expensive and damaging to the pavement and provides potentially unreliable electrical connections. The new systems consist of a retrofitted instrumented asphalt core which is bonded into the pavement structure. The core contains all the electronics necessary to record two temperatures and two strains. An analogue front end provides signal conditioning which is digitized and passed to microcontroller for endcoding. From there the data is transmitted via a low power radio link to a receiver and data logger positioned by the side of the road. The system has an in-situ operating life of 6 months on AA alkaline batteries. Results are presented of power management and fault tolerant radio protocol techniques, long term temperature variations, dynamic strain measurements within the highway, and RF transmission capabilities through a layer of asphalt.

  10. Combine mobile monitoring conception

    Energy Technology Data Exchange (ETDEWEB)

    Stolyarevsky, I.; Ivanov, J.A.; Arkhipov, N. [Chernobyl Scientific and Technical Center for International Researches (CHESCIR) (Ukraine)] [and others

    2001-03-01

    This work is a document of joint final report of the collaboration between CHESCIR and JAERI on the Subject-1 'A Study on the Measurements and Evaluation of External Dose after Nuclear Accident' of JCP-1 project 'A Study on the Assessment, Analysis and Verification of the Consequences of the accident at Chernobyl' in the framework of the Agreement between JAERI and RIA 'PRIPYAT' (since 1994, CHESCIR) for 1995-1999. The most substantial part of the collaboration was research with using mobile gamma survey system, that was developed in JAERI and equipped with GIS - navigator that was developed in CHESCIR. During collaboration the carbone survey on the network of roads covered most are contaminated by Chernobyl fallout in Ukraine, Belorussia and Russia. Routes of carbone survey, carried out by CHESCIR team together with JAERI and alone for the last 5 years are shown in a non-complete map. Length of all routes taking into considers double raids is longer than 18,000 km. Experimental and methodological experience of mobile monitoring that collected by both sides allows to make considerations and conclusions, which are available in this final report. (J.P.N.)

  11. Site specific modification of the human plasma proteome by methylglyoxal

    International Nuclear Information System (INIS)

    Kimzey, Michael J.; Kinsky, Owen R.; Yassine, Hussein N.; Tsaprailis, George; Stump, Craig S.; Monks, Terrence J.; Lau, Serrine S.

    2015-01-01

    Increasing evidence identifies dicarbonyl stress from reactive glucose metabolites, such as methylglyoxal (MG), as a major pathogenic link between hyperglycemia and complications of diabetes. MG covalently modifies arginine residues, yet the site specificity of this modification has not been thoroughly investigated. Sites of MG adduction in the plasma proteome were identified using LC–MS/MS analysis in vitro following incubation of plasma proteins with MG. Treatment of plasma proteins with MG yielded 14 putative MG hotspots from five plasma proteins (albumin [nine hotspots], serotransferrin, haptoglobin [2 hotspots], hemopexin, and Ig lambda-2 chain C regions). The search results revealed two versions of MG-arginine modification, dihydroxyimidazolidine (R + 72) and hydroimidazolone (R + 54) adducts. One of the sites identified was R257 in human serum albumin, which is a critical residue located in drug binding site I. This site was validated as a target for MG modification by a fluorescent probe displacement assay, which revealed significant drug dissociation at 300 μM MG from a prodan–HSA complex (75 μM). Moreover, twelve human plasma samples (six male, six female, with two type 2 diabetic subjects from both genders) were analyzed using multiple reaction monitoring (MRM) tandem mass spectrometry and revealed the presence of the MG-modified albumin R257 peptide. These data provide insights into the nature of the site-specificity of MG modification of arginine, which may be useful for therapeutic treatments that aim to prevent MG-mediated adverse responses in patients. - Highlights: • Methylglyoxal (MG) selectively modifies arginine sites in human plasma proteome. • Dihydroxyimidazolidine and hydroimidazolone adducts on serum albumin identified • MG modification on albumin R257 associated with loss of drug site I binding capacity • MRM-tandem mass spectrometry enables sensitive detection of albumin MG-R257. • Site-specific MG modification may

  12. Site specific modification of the human plasma proteome by methylglyoxal

    Energy Technology Data Exchange (ETDEWEB)

    Kimzey, Michael J.; Kinsky, Owen R. [Southwest Environmental Health Sciences Center, Department of Pharmacology & Toxicology, College of Pharmacy, The University of Arizona, Tucson, AZ 85721 (United States); Yassine, Hussein N. [Department of Medicine, The University of Arizona, Tucson, AZ 85721 (United States); Tsaprailis, George [Southwest Environmental Health Sciences Center, Department of Pharmacology & Toxicology, College of Pharmacy, The University of Arizona, Tucson, AZ 85721 (United States); Stump, Craig S. [Department of Medicine, The University of Arizona, Tucson, AZ 85721 (United States); Southern Arizona VA Health Care System, Tucson, AZ 85723 (United States); Monks, Terrence J. [Southwest Environmental Health Sciences Center, Department of Pharmacology & Toxicology, College of Pharmacy, The University of Arizona, Tucson, AZ 85721 (United States); Lau, Serrine S., E-mail: lau@pharmacy.arizona.edu [Southwest Environmental Health Sciences Center, Department of Pharmacology & Toxicology, College of Pharmacy, The University of Arizona, Tucson, AZ 85721 (United States)

    2015-12-01

    Increasing evidence identifies dicarbonyl stress from reactive glucose metabolites, such as methylglyoxal (MG), as a major pathogenic link between hyperglycemia and complications of diabetes. MG covalently modifies arginine residues, yet the site specificity of this modification has not been thoroughly investigated. Sites of MG adduction in the plasma proteome were identified using LC–MS/MS analysis in vitro following incubation of plasma proteins with MG. Treatment of plasma proteins with MG yielded 14 putative MG hotspots from five plasma proteins (albumin [nine hotspots], serotransferrin, haptoglobin [2 hotspots], hemopexin, and Ig lambda-2 chain C regions). The search results revealed two versions of MG-arginine modification, dihydroxyimidazolidine (R + 72) and hydroimidazolone (R + 54) adducts. One of the sites identified was R257 in human serum albumin, which is a critical residue located in drug binding site I. This site was validated as a target for MG modification by a fluorescent probe displacement assay, which revealed significant drug dissociation at 300 μM MG from a prodan–HSA complex (75 μM). Moreover, twelve human plasma samples (six male, six female, with two type 2 diabetic subjects from both genders) were analyzed using multiple reaction monitoring (MRM) tandem mass spectrometry and revealed the presence of the MG-modified albumin R257 peptide. These data provide insights into the nature of the site-specificity of MG modification of arginine, which may be useful for therapeutic treatments that aim to prevent MG-mediated adverse responses in patients. - Highlights: • Methylglyoxal (MG) selectively modifies arginine sites in human plasma proteome. • Dihydroxyimidazolidine and hydroimidazolone adducts on serum albumin identified • MG modification on albumin R257 associated with loss of drug site I binding capacity • MRM-tandem mass spectrometry enables sensitive detection of albumin MG-R257. • Site-specific MG modification may

  13. Advances in radiation protection monitoring

    International Nuclear Information System (INIS)

    1978-01-01

    The requirement to keep radiation exposure as low as reasonably achievable, linked with the growing number of workers whose exposure to radiation must be strictly controlled, requires intensified efforts directed towards the provision of adequate radiation monitoring programmes. This symposium was intended to review the advances that have been made in methods, techniques and instrumentation for radiation protection monitoring. Thus the symposium complemented the detailed consideration that had already been given to two closely related topics, that of environmental monitoring and of monitoring radioactive airborne and liquid discharges from nuclear facilities. The first topic had been dealt with in detail in an Agency symposium held in November 1973 in Warsaw and the second was treated in an Agency symposium held in September 1977 in Portoroz. The present symposium covered a broad range of topics under the following main headings: Monitoring of external exposure (three sessions),Contamination monitoring (three sessions), Radiation monitoring programmes (one session), Calibration, and use of computers (two sessions). An introductory paper described the purpose of radiation protection monitoring and its historical development. It drew attention to the gradual change from the threshold dose hypothesis to the hypothesis of direct proportionality between dose and effect and discussed practical implications of the recommendations recently issued by the International Commission on Radiological Protection (ICRP). It became apparent that guidance on the application of these recommendations is urgently needed. This guidance is presently being prepared by ICRP

  14. Advances in Monitoring the Economy

    NARCIS (Netherlands)

    R. Segers (René)

    2009-01-01

    textabstractMonitoring involves the collection, analysis and evaluation of information over time. For many professionals, monitoring is a central aspect of their work. For example, policy- makers closely watch the e®ects of their current policies to set the right course for reform. Likewise,

  15. Environmental radioactivity. Measurement and monitoring

    International Nuclear Information System (INIS)

    2009-11-01

    The contribution on environmental radioactivity covers the following issues: natural and artificial radioactivity; continuous monitoring of radioactivity; monitoring authorities and measurement; radioactivity in the living environment; radioactivity in food and feeding stuff; radioactivity of game meat and wild-growing mushrooms; radioactivity in mines; radioactivity in the research center Rossendorf.

  16. Monitoring in South African grasslands

    CSIR Research Space (South Africa)

    Mentis, MT

    1984-12-01

    Full Text Available The main purpose of this document is to propose how ecological monitoring might be developed in the Grassland Biome of South Africa. Monitoring is defined as the maintenance of regular surveillance to test the null hypothesis of no change...

  17. Monitoring and evaluating soil quality

    NARCIS (Netherlands)

    Bloem, J.; Schouten, A.J.; Sørensen, S.J.; Rutgers, M.; Werf, van der A.K.; Breure, A.M.

    2006-01-01

    This book provides a selection of microbiological methods that are already applied in regional or national soil quality monitoring programs. It is split into two parts: part one gives an overview of approaches to monitoring, evaluating and managing soil quality. Part two provides a selection of

  18. Ground-based photo monitoring

    Science.gov (United States)

    Frederick C. Hall

    2000-01-01

    Ground-based photo monitoring is repeat photography using ground-based cameras to document change in vegetation or soil. Assume those installing the photo location will not be the ones re-photographing it. This requires a protocol that includes: (1) a map to locate the monitoring area, (2) another map diagramming the photographic layout, (3) type and make of film such...

  19. Air and radiation monitoring stations

    CERN Multimedia

    AUTHOR|(SzGeCERN)582709

    2015-01-01

    CERN has around 100 monitoring stations on and around its sites. New radiation measuring stations, capable of detecting even lower levels of radiation, were installed in 2014. Two members of HE-SEE group (Safety Engineering and Environment group) in front of one of the new monitoring stations.

  20. Intraesophageal impedance monitoring: clinical studies

    NARCIS (Netherlands)

    Conchillo Armendáriz, J.M.

    2007-01-01

    Electrical impedance (Z) between two electrodes is the ratio between applied voltage (U) and resulting current (I). In electrical impedance monitoring the resistance to electrical flow in an alternating current circuit is measured. Multichannel esophageal monitoring can be measured by using an

  1. Pantex Plant meteorological monitoring program

    International Nuclear Information System (INIS)

    Snyder, S.F.

    1993-07-01

    The current meteorological monitoring program of the US Department of Energy's Pantex Plant, Amarillo, Texas, is described in detail. Instrumentation, meteorological data collection and management, and program management are reviewed. In addition, primary contacts are noted for instrumentation, calibration, data processing, and alternative databases. The quality assurance steps implemented during each portion of the meteorological monitoring program are also indicated

  2. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  3. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  4. Environmental monitoring for krypton-85

    International Nuclear Information System (INIS)

    Barber, D.E.

    1973-01-01

    85 Kr presents unique environmental monitoring problems because it does not react with other elements and compounds at normal ambient temperatures and pressures. However, elaborate means are available to manage the 85 Kr problem, but a simpler, inexpensive approach is required if monitoring is to be accomplished at many sampling locations. This work shows that environmental monitoring for 85 Kr is possible by collecting air samples in thin plastic bags, and counting the bags for beta particle activity. The direct counting of contained samples of this type makes it possible to detect concentrations less than the public MPC for 85 Kr. The bagged-sample technique is readily adaptable to any environmental monitoring station with power to run a low-volume air pump. The idea of counting the bagged-sample directly is a new, low-cost, approach to environmental gas monitoring which may have application in environmental, clinical, and industrial situations

  5. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  6. MCO Monitoring issue closure package

    International Nuclear Information System (INIS)

    SEXTON, R.A.

    1998-01-01

    Agreement on a focused, limited approach to MCO monitoring has been documented. While the value of monitoring has been understood by those interested in the SNF Project, there had been a diversity of opinion on details of approach and implementation. For this reason, MCO monitoring had been identified as a technical issue. A cooperative effort involving the contractor, RL, and the technical assistance group (TAG), resulted in the definition of an approach agreeable to all and of the remaining details to be resolved through conceptual engineering. MCO monitoring will consist of temperature, pressure, and gas composition monitoring of 4 to 6 MCOs for up to two years. High pressure detection capability for the duration of interim storage for every MCO will also be evaluated and implemented within the current project baseline, if possible. Otherwise a BCR will be prepared and submitted

  7. Monitoring Technology Meets Care Work

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Bygholm, Ann

    2015-01-01

    's ability to meet the complexity of care work. Understanding intersectional challenges between these care technologies and care work is fundamental to improve design and use of health informatics. In this paper we present an analysis of interaction challenges between a wet-sensor at the task of monitoring......Monitoring technology, especially sensor-based technology, is increasingly taken into use in care work. Despite the simplicity of these technologies – aimed to automate what appear as mundane monitoring tasks – recent research has identified major challenges primarily related to the technology...... wet beds at a nursing home. The analysis identifies the multifaceted nature of monitoring work and the intricacy of integrating sensor technology into the complex knowledge system of monitoring work....

  8. Heat exchanger performance monitoring guidelines

    International Nuclear Information System (INIS)

    Stambaugh, N.; Closser, W. Jr.; Mollerus, F.J.

    1991-12-01

    Fouling can occur in many heat exchanger applications in a way that impedes heat transfer and fluid flow and reduces the heat transfer or performance capability of the heat exchanger. Fouling may be significant for heat exchanger surfaces and flow paths in contact with plant service water. This report presents guidelines for performance monitoring of heat exchangers subject to fouling. Guidelines include selection of heat exchangers to monitor based on system function, safety function and system configuration. Five monitoring methods are discussed: the heat transfer, temperature monitoring, temperature effectiveness, delta P and periodic maintenance methods. Guidelines are included for selecting the appropriate monitoring methods and for implementing the selected methods. The report also includes a bibliography, example calculations, and technical notes applicable to the heat transfer method

  9. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  10. MONITORING OF MINING

    Directory of Open Access Journals (Sweden)

    Berislav Šebečić

    1996-12-01

    Full Text Available The way mining was monitored in the past depended on knowledge, interest and the existing legal regulations. Documentary evidence about this work can be found in archives, libraries and museums. In particular, there is the rich archival material (papers and books concerning the work of the one-time Imperial and Royal Mining Captaincies in Zagreb, Zadar, Klagenfurt and Split, A minor part of the documentation has not yet been transferred to Croatia. From mining handbooks and books we can also find out about mining in Croatia. In the context of Austro-Hungary. For example, we can find out that the first governorships in Zagreb and Zadar headed the Ban, Count Jelacic and Baron Mamula were also the top mining authorities, though this, probably from political motives, was suppressed in the guides and inventories or the Mining Captaincies. At the end of the 1850s, Croatia produced 92-94% of sea salt, up to 8.5% of sulphur, 19.5% of asphalt and 100% of oil for the Austro-Hungarian empire. From data about mining in the Split Mining Captaincy, prepared for the Philadephia Exhibition, it can be seen that in the exploratory mining operations in which there were 33,372 independent mines declared in 1925 they were looking mainly for bauxite (60,0%, then dark coal (19,0%, asphalts (10.3% and lignites (62%. In 1931, within the area covered by the same captaincy, of 74 declared mines, only 9 were working. There were five coal mines, three bauxite mines and one for asphalt. I suggest that within state institution, the Mining Captaincy or Authority be renewed, or that a Mining and Geological Authority be set ap, which would lead to the more complete affirmation of Croatian mining (the paper is published in Croatian.

  11. Mosses in Radioactive Monitoring

    International Nuclear Information System (INIS)

    Marovic, G.; Franic, Z.; Sencar, J.

    2008-01-01

    Mosses, lichens and perennial plants, all characterized by slow growth, are able to efficiently accumulate different radionuclides from their environment to a much higher degree than other vegetation. Consequently, they are sensitive bio indicators of radioactive contamination for various ecosystems. Results of systematic, long-term measurements of 137Cs activities in mosses for the period 1986-2007 are summarized. The study was conducted in the Radiation Protection Unit of the Institute for Medical Research and Occupational Health in Zagreb, as a part of an extensive monitoring program of the Croatian environment. In the overall observed period the highest activity concentration of 137Cs deposited by fallout has been recorded in 1986, which is the year of Chernobyl accident, causing peak 137Cs activity concentration in moss of 8800 Bqkg -1 in May 1986. Mean value for period 1986 - 1990 was 3423 Bqkg -1 . For comparison, in the same period mean 137Cs activity concentration in grass was 390 Bqkg -1 . In 1990s, ten year after Chernobyl accident, mean 137Cs activity concentration in moss was 1345 Bqkg -1 , with maximum value of 3940 Bqkg -1 (December 1994). In 2000s, mean 137Cs activity concentration in mosses was 172 Bqkg -1 with maximum value of 955 Bqkg -1 (July 2002). Fitting the measured 137Cs activity concentrations to the theoretical curve (1) the ecological half-life of 137Cs in moss was found to be about 978 days, while in grass was found to be about 126 days in the period 1986 - 1990. The ecological half-life of 137Cs in grass after 1991 was found to be about 2503 days. The ecological half-life of 137Cs in moss is about eight times higher than 137Cs ecological half-life observed in grass in the first period after the Chernobyl accident.(author)

  12. Remote radiation environmental monitoring

    International Nuclear Information System (INIS)

    Pashayev, A.M.; Mehdiyev, A.Sh.; Bayramov, A.A.

    2003-01-01

    Full text: The project of the automated remote monitoring for a level of an environment background radiation in settlements along boundary of the Azerbaijan Republic is developed. The main purpose of the project is: increase of a level of a radiation safety on territory of the Azerbaijan Republic; controlling of a level of an environment background radiation on boundary of the Azerbaijan Republic with the purpose of well-timed warning and acceptance of indispensable measures at probable emergencies on Atomic Power Stations in a number adjacent from Azerbaijan countries, or other ecological catastrophes; controlling of a level of an environment background radiation along eastern suburbs of Azerbaijan regions occupied of Armenia's army and detection of the facts of wrongful disposals of atomic engineering of Armenia on territory of Azerbaijan. As is known, in a number adjacent from Azerbaijan countries the nuclear industry is advanced or develops. It has resulted in origin of threat of a radiation hazard in case of ecological catastrophes: widely scale leakage of radioactive wastes, explosions, or fires on nuclear generating sets, acts of sabotage, directional against Azerbaijan. In this case, at unfavorable meteorological conditions a radioactive waste may be brought by a wind or a rain on territory of Azerbaijan. Measurement is supposed a carry with the help of 'EKOMON' fixed stations. The results of round-the-clock a gamma and a neutron background measurement from the stations will be transmitted automatically to a dispatcher station in the central computer. Established on the stations telescopic sensors also will allow to determine a direction of a radiation and coordinates of radiation source. Stations will be located along boundary, and also in Kedabek, Akstafa, Terter, Agdam and Fizuli regions, and in Autonomous Republic of Nakhichevan

  13. Remote monitoring in international safeguards

    International Nuclear Information System (INIS)

    Dupree, S.A.; Sonnier, C.S.; Johnson, C.S.

    1996-01-01

    In recent years, technology that permits the integration of monitoring sensors and instruments into a coherent network has become available. Such integrated monitoring systems provide a means for the automatic collection and assessment of sensor signals and instrument readings and for processing such signals and readings in near real time. To gain experience with the new monitoring system technology, the US Department of energy, through bilateral agreements with its international partners, has initiated a project to emplace demonstration systems in various nuclear facilities and conduct field trials of the technology. This effort is the International Remote Monitoring Project. Under this project, remote monitoring systems are being deployed around the world in an incremental manner. Each deployment is different and each offers lessons for improving the performance and flexibility of the technology. Few problems were encountered with the operation of the installations to date, and much has been learned about the operation and use of the new technology. In the future, the authors believe systems for safeguards applications should be capable of being monitored remotely, emphasize the use of sensors, and utilize selective triggering for recording of images. Remote monitoring across national borders can occur only in the context of a cooperative, nonadversarial implementation regime. However, significant technical and policy work remains to be done before widespread safeguards implementation of remote monitoring should be considered. This paper shows that an abundance of technology supports the implementation of integrated and remote monitoring systems. Current field trials of remote monitoring systems are providing practical data and operational experience to aid in the design of tomorrow's systems

  14. Monitoring in beeld: een studie naar de doorwerking van monitors in interbestuurlijke relaties

    NARCIS (Netherlands)

    D. de Kool (Dennis)

    2007-01-01

    textabstractMonitoring in the Dutch public sector An increasing stream of monitoring activities has entered the public sector. A lot of different monitors have been implemented in the Netherlands, like the police monitor, drugs monitor, integration monitor and the emancipation monitor. Although

  15. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  16. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  17. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  18. Saltwater intrusion monitoring in Florida

    Science.gov (United States)

    Prinos, Scott T.

    2016-01-01

    Florida's communities are largely dependent on freshwater from groundwater aquifers. Existing saltwater in the aquifers, or seawater that intrudes parts of the aquifers that were fresh, can make the water unusable without additional processing. The quality of Florida's saltwater intrusion monitoring networks varies. In Miami-Dade and Broward Counties, for example, there is a well-designed network with recently constructed short open-interval monitoring wells that bracket the saltwater interface in the Biscayne aquifer. Geochemical analyses of water samples from the network help scientists evaluate pathways of saltwater intrusion and movement of the saltwater interface. Geophysical measurements, collected in these counties, aid the mapping of the saltwater interface and the design of monitoring networks. In comparison, deficiencies in the Collier County monitoring network include the positioning of monitoring wells, reliance on wells with long open intervals that when sampled might provide questionable results, and the inability of existing analyses to differentiate between multiple pathways of saltwater intrusion. A state-wide saltwater intrusion monitoring network is being planned; the planned network could improve saltwater intrusion monitoring by adopting the applicable strategies of the networks of Miami-Dade and Broward Counties, and by addressing deficiencies such as those described for the Collier County network.

  19. Uncertainty of dustfall monitoring results

    Directory of Open Access Journals (Sweden)

    Martin A. van Nierop

    2017-06-01

    Full Text Available Fugitive dust has the ability to cause a nuisance and pollute the ambient environment, particularly from human activities including construction and industrial sites and mining operations. As such, dustfall monitoring has occurred for many decades in South Africa; little has been published on the repeatability, uncertainty, accuracy and precision of dustfall monitoring. Repeatability assesses the consistency associated with the results of a particular measurement under the same conditions; the consistency of the laboratory is assessed to determine the uncertainty associated with dustfall monitoring conducted by the laboratory. The aim of this study was to improve the understanding of the uncertainty in dustfall monitoring; thereby improving the confidence in dustfall monitoring. Uncertainty of dustfall monitoring was assessed through a 12-month study of 12 sites that were located on the boundary of the study area. Each site contained a directional dustfall sampler, which was modified by removing the rotating lid, with four buckets (A, B, C and D installed. Having four buckets on one stand allows for each bucket to be exposed to the same conditions, for the same period of time; therefore, should have equal amounts of dust deposited in these buckets. The difference in the weight (mg of the dust recorded from each bucket at each respective site was determined using the American Society for Testing and Materials method D1739 (ASTM D1739. The variability of the dust would provide the confidence level of dustfall monitoring when reporting to clients.

  20. Monitor Sustainable Netherlands 2011; Monitor Duurzaam Nederland 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [Dutch] De Monitor geeft een beeld van de duurzaamheid van de Nederlandse samenleving. Het laat zien op welke terreinen het goed gaat en waar er vanuit een duurzaamheidsoptiek 'zorgen voor morgen' bestaan. Geanalyseerd wordt hoe ons land ervoor staat op het gebied van klimaatverandering, biodiversiteit, gezondheid, kennis, vergrijzing en sociale cohesie. Deze, en vele andere onderwerpen worden in deze monitor behandeld aan de hand van een set van duurzaamheidsindicatoren en detailanalyses.

  1. Monitor Sustainable Netherlands 2009; Monitor Duurzaam Nederland 2009

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-02-15

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [Dutch] De Monitor geeft een beeld van de duurzaamheid van de Nederlandse samenleving. Hij laat zien op welke terreinen het goed gaat en waar er vanuit een duurzaamheidsoptiek 'zorgen voor morgen' bestaan. Geanalyseerd wordt hoe ons land ervoor staat op het gebied van klimaatverandering, biodiversiteit, gezondheid, kennis, vergrijzing en sociale cohesie. Deze, en vele andere onderwerpen worden in deze monitor behandeld aan de hand van een set van duurzaamheidsindicatoren en detailanalyses.

  2. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  3. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  4. Microprocessor multi-task monitor

    International Nuclear Information System (INIS)

    Ludemann, C.A.

    1983-01-01

    This paper describes a multi-task monitor program for microprocessors. Although written for the Intel 8085, it incorporates features that would be beneficial for implementation in other microprocessors used in controlling and monitoring experiments and accelerators. The monitor places permanent programs (tasks) arbitrarily located throughout ROM in a priority ordered queue. The programmer is provided with the flexibility to add new tasks or modified versions of existing tasks, without having to comply with previously defined task boundaries or having to reprogram all of ROM. Scheduling of tasks is triggered by timers, outside stimuli (interrupts), or inter-task communications. Context switching time is of the order of tenths of a milllisecond

  5. Indicators for Monitoring Soil Biodiversity

    DEFF Research Database (Denmark)

    Bispo, A.; Cluzeau, D.; Creamer, R.

    2009-01-01

    is made for a set of suitable indicators for monitoring the decline in soil biodiversity (Bispo et al. 2007). These indicators were selected both from a literature review and an inventory of national monitoring programmes. Decline in soil biodiversity was defined as the reduction of forms of life living...... indicators are actually measured.   For monitoring application it was considered in ENVASSO that only three key indicators per soil stress were practical. For indicating biodiversity decline it was difficult to arrive at a small set of indicators due to the complexity of soil biota and functions. Therefore...

  6. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  7. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  8. On monitoring unrecorded alcohol consumption

    Directory of Open Access Journals (Sweden)

    Jürgen Rehm

    2015-06-01

    Full Text Available Unrecorded alcohol consumption is a global problem, with about 25% of all alcohol consumption concerning this category. There are different forms of unrecorded alcohol, legally produced versus illegally produced, artisanal vs industrially produced, and then surrogate alcohol, which is officially not intended for human consumption. Monitoring and surveillance of unrecorded consumption is not well developed. The World Health Organization has developed a monitoring system, using the Nominal Group Technique, a variant of the Delphi methodology. Experiences with this methodology over the past two years are reported. Finally, conclusions for the monitoring and surveillance at the national level are given.

  9. Monitoring of Underground Coal Gasification

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wagoner, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramirez, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2012-08-31

    For efficient and responsible UCG operations, a UCG process must be monitored in the following three categories: 1) process parameters such as injection and product gas flow rates, temperature, pressure and syngas content and heating value; 2) geomechanical parameters, e.g., cavity and coal seam pressures, cavity development, subsidence and ground deformation; and 3) environmental parameters, e.g., groundwater chemistry and air quality. This report focuses on UCG monitoring with geophysical techniques that can contribute to monitoring of subsurface temperature, cavity development, burn front, subsidence and deformation.

  10. High temperature water chemistry monitoring

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1992-01-01

    Almost all corrosion phenomena in nuclear power plants can be prevented or at least damped by water chemistry control or by the change of water chemistry control or by the change of water chemistry. Successful water chemistry control needs regular and continuous monitoring of such water chemistry parameters like dissolved oxygen content, pH, conductivity and impurity contents. Conventionally the monitoring is carried out at low pressures and temperatures, which method, however, has some shortcomings. Recently electrodes have been developed which enables the direct monitoring at operating pressures and temperatures. (author). 2 refs, 5 figs

  11. Environmental monitoring of Chinook Salmon

    International Nuclear Information System (INIS)

    Morris, D.; Boreham, D.

    2008-01-01

    The importance of monitoring plants and animals in the environment as become increasingly important with recent developments over the past few years. New ICRP recommendations, coming into effect summer 2007, require the monitoring of non-human biota. There is increasing public concern for safety and general well-being of plants and animals near nuclear reactors and other nuclear facilities. However, most current monitoring techniques do not adequately address this concern. I will discuss several current biological techniques to address the radiation sensitivity animals in the environment, including their advantages and drawbacks. Our research has examined several aquatic animals to determine their sensitivity to radiation. (author)

  12. 40 CFR 141.601 - Standard monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Standard monitoring. 141.601 Section... Standard monitoring. (a) Standard monitoring plan. Your standard monitoring plan must comply with paragraphs (a)(1) through (a)(4) of this section. You must prepare and submit your standard monitoring plan...

  13. 40 CFR 61.68 - Emission monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Emission monitoring. 61.68 Section 61....68 Emission monitoring. (a) A vinyl chloride monitoring system is to be used to monitor on a... monitoring system(s) used to meet the requirement in paragraph (a) of this section is to be a device which...

  14. 10 CFR 850.24 - Exposure monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Exposure monitoring. 850.24 Section 850.24 Energy... Exposure monitoring. (a) General. The responsible employer must ensure that: (1) Exposure monitoring is... activities properly. (b) Initial monitoring. The responsible employer must perform initial monitoring in...

  15. Tool wear and breakage monitoring in machining

    International Nuclear Information System (INIS)

    Madl, J.

    1992-01-01

    Risk minimization of metal cutting operations is one of the main problems of metal cutting technology. This paper describes some aspects in monitoring and control of machining processes. Tool monitoring is the fokus of machining process monitoring. Tool breakage and tool life recognition are the main problems of tool monitoring. All problems of this type of monitoring have not yet been fully solved. (orig.)

  16. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  17. Radiation detectors as surveillance monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Dowdy, E.J.

    1981-01-01

    The International Atomic Energy Agency (IAEA) proposes to use personnel dosimetry radiation detectors as surveillance monitors for safeguards purposes. It plans to place these YES/NO monitors at barrier penetration points declared closed under IAEA safeguards to detect the passage of plutonium-bearing nuclear material, usually spent fuel. For this application, commercially available dosimeters were surveyed as well as other radiation detectors that appeared suitable and likely to be marketed in the near future. No primary advantage was found in a particular detector type because in this application backgrounds vary during long counting intervals. Secondary considerations specify that the monitor be inexpensive and easy to tamper-proof, interrogate, and maintain. On this basis radiophotoluminescent, thermoluminescent, and electronic dosimeters were selected as possible routine monitors; the latter two may prove useful for data-base acquisition

  18. GPS Civil Monitoring Performance Specification

    Science.gov (United States)

    2009-02-10

    This Civil Monitoring Performance Specification (CMPS) is published and maintained at : the direction of the Program Manager for Civil Applications, Global Positioning Systems : Wing (GPSW). The purpose of this document is to provide a comprehensive ...

  19. Instrumentation for Air Pollution Monitoring

    Science.gov (United States)

    Hollowell, Craig D.; McLaughlin, Ralph D.

    1973-01-01

    Describes the techniques which form the basis of current commercial instrumentation for monitoring five major gaseous atmospheric pollutants (sulfur dioxide, oxides of nitrogen, oxidants, carbon monoxide, and hydrocarbons). (JR)

  20. Volunteer Monitoring to Protect Wetlands

    Science.gov (United States)

    The involvement of volunteers in ecological monitoring is a realistic, cost-effective, and beneficial way to obtain important information which might otherwise be unavailable due to lack of resources at government agencies.