WorldWideScience

Sample records for multiple image sequences

  1. The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques.

    Science.gov (United States)

    Farshidfar, Z; Faeghi, F; Haghighatkhah, H R; Abdolmohammadi, J

    2017-09-01

    Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don't have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is evaluating the efficiency of different MRI sequences in order to better detection of MS plaques. In this cross-sectional study which was performed at Shohada-E Tajrish in Tehran - Iran hospital between October, 2011 to April, 2012, included 20 patients who suspected to MS disease were selected by the method of random sampling and underwent routine brain Pulse sequences (Axial T2w, Axial T1w, Coronal T2w, Sagittal T1w, Axial FLAIR) by Siemens, Avanto, 1.5 Tesla system. If any lesion which is suspected to the MS disease was observed, additional sequences such as: Sagittal FLAIR Fat Sat, Sagittal PDw-fat Sat, Sagittal PDw-water sat was also performed. This study was performed in about 52 lesions and the results in more than 19 lesions showed that, for the Subcortical and Infratentorial areas, PDWw sequence with fat suppression is the best choice, And in nearly 33 plaques located in Periventricular area, FLAIR Fat Sat was the most effective sequence than both PDw fat and water suppression pulse sequences. Although large plaques may visible in all images, but important problem in patients with suspected MS is screening the tiny MS plaques. This study showed that for revealing the MS plaques located in the Subcortical and Infratentorial areas, PDw-fat sat is the most effective sequence, and for MS plaques in the periventricular area, FLAIR fat Sat is the best choice.

  2. Magnetic resonance imaging of multiple sclerosis brain lesions: A semeiologic study by multiple spin-echo sequences

    International Nuclear Information System (INIS)

    Caires, M.C.; Scheiber, C.; Rumbach, L.; Gounot, D.; Dumitresco, B.; Warter, J.M.; Collard, M.; Chambron, J.

    1986-01-01

    Nuclear magnetic resonance imaging (MRI) if the brain is now known as a very sensitive tool for clearly revealing lesions in white matter, and has thus become important in the study of multiple sclerosis (MS). Since 1981, others have shown the best of MRI: we can see 6 x more lesions than CT. MRI contrast bases mainly on the spatial heterogeneity of the relaxation time of different tissues. The sensitivity depends on the longer T1 and/or T2 of the pathological tissues compared to those of normal tissues. In our series, the authors use mainly T2 weighted MR images and they evaluate their interest for the diagnosis of MS. They study the frequency of the abnormalities and their semeiology in a small number of transversal sections imaged at the level of the lateral ventricles. The authors' aim is to describe the NMR-derived morphological signs of MS and to prospect its interest in the physiopathological studies of this disease

  3. An Improved Image Encryption Algorithm Based on Cyclic Rotations and Multiple Chaotic Sequences: Application to Satellite Images

    Directory of Open Access Journals (Sweden)

    MADANI Mohammed

    2017-10-01

    Full Text Available In this paper, a new satellite image encryption algorithm based on the combination of multiple chaotic systems and a random cyclic rotation technique is proposed. Our contribution consists in implementing three different chaotic maps (logistic, sine, and standard combined to improve the security of satellite images. Besides enhancing the encryption, the proposed algorithm also focuses on advanced efficiency of the ciphered images. Compared with classical encryption schemes based on multiple chaotic maps and the Rubik's cube rotation, our approach has not only the same merits of chaos systems like high sensitivity to initial values, unpredictability, and pseudo-randomness, but also other advantages like a higher number of permutations, better performances in Peak Signal to Noise Ratio (PSNR and a Maximum Deviation (MD.

  4. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain

    2014-12-04

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green\\'s function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green\\'s function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green\\'s function and renders the higher order internal multiple image for display on a display device.

  5. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain; Alkhalifah, Tariq

    2014-01-01

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green's function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green's function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green's function and renders the higher order internal multiple image for display on a display device.

  6. Imaging 2015 Mw 7.8 Gorkha Earthquake and Its Aftershock Sequence Combining Multiple Calibrated Global Seismic Arrays

    Science.gov (United States)

    LI, B.; Ghosh, A.

    2016-12-01

    The 2015 Mw 7.8 Gorkha earthquake provides a good opportunity to study the tectonics and earthquake hazards in the Himalayas, one of the most seismically active plate boundaries. Details of the seismicity patterns and associated structures in the Himalayas are poorly understood mainly due to limited instrumentation. Here, we apply a back-projection method to study the mainshock rupture and the following aftershock sequence using four large aperture global seismic arrays. All the arrays show eastward rupture propagation of about 130 km and reveal similar evolution of seismic energy radiation, with strong high-frequency energy burst about 50 km north of Kathmandu. Each single array, however, is typically limited by large azimuthal gap, low resolution, and artifacts due to unmodeled velocity structures. Therefore, we use a self-consistent empirical calibration method to combine four different arrays to image the Gorkha event. It greatly improves the resolution, can better track rupture and reveal details that cannot be resolved by any individual array. In addition, we also use the same arrays at teleseismic distances and apply a back-projection technique to detect and locate the aftershocks immediately following the Gorkha earthquake. We detect about 2.5 times the aftershocks recorded by the Advance National Seismic System comprehensive earthquake catalog during the 19 days following the mainshock. The aftershocks detected by the arrays show an east-west trend in general, with majority of the aftershocks located at the eastern part of the rupture patch and surrounding the rupture zone of the largest Mw 7.3 aftershock. Overall spatiotemporal aftershock pattern agrees well with global catalog, with our catalog showing more details relative to the standard global catalog. The improved aftershock catalog enables us to better study the aftershock dynamics, stress evolution in this region. Moreover, rapid and better imaging of aftershock distribution may aid rapid response

  7. Sequence Factorization with Multiple References.

    Directory of Open Access Journals (Sweden)

    Sebastian Wandelt

    Full Text Available The success of high-throughput sequencing has lead to an increasing number of projects which sequence large populations of a species. Storage and analysis of sequence data is a key challenge in these projects, because of the sheer size of the datasets. Compression is one simple technology to deal with this challenge. Referential factorization and compression schemes, which store only the differences between input sequence and a reference sequence, gained lots of interest in this field. Highly-similar sequences, e.g., Human genomes, can be compressed with a compression ratio of 1,000:1 and more, up to two orders of magnitude better than with standard compression techniques. Recently, it was shown that the compression against multiple references from the same species can boost the compression ratio up to 4,000:1. However, a detailed analysis of using multiple references is lacking, e.g., for main memory consumption and optimality. In this paper, we describe one key technique for the referential compression against multiple references: The factorization of sequences. Based on the notion of an optimal factorization, we propose optimization heuristics and identify parameter settings which greatly influence 1 the size of the factorization, 2 the time for factorization, and 3 the required amount of main memory. We evaluate a total of 30 setups with a varying number of references on data from three different species. Our results show a wide range of factorization sizes (optimal to an overhead of up to 300%, factorization speed (0.01 MB/s to more than 600 MB/s, and main memory usage (few dozen MB to dozens of GB. Based on our evaluation, we identify the best configurations for common use cases. Our evaluation shows that multi-reference factorization is much better than single-reference factorization.

  8. Region segmentation along image sequence

    International Nuclear Information System (INIS)

    Monchal, L.; Aubry, P.

    1995-01-01

    A method to extract regions in sequence of images is proposed. Regions are not matched from one image to the following one. The result of a region segmentation is used as an initialization to segment the following and image to track the region along the sequence. The image sequence is exploited as a spatio-temporal event. (authors). 12 refs., 8 figs

  9. Image sequence analysis

    CERN Document Server

    1981-01-01

    The processing of image sequences has a broad spectrum of important applica­ tions including target tracking, robot navigation, bandwidth compression of TV conferencing video signals, studying the motion of biological cells using microcinematography, cloud tracking, and highway traffic monitoring. Image sequence processing involves a large amount of data. However, because of the progress in computer, LSI, and VLSI technologies, we have now reached a stage when many useful processing tasks can be done in a reasonable amount of time. As a result, research and development activities in image sequence analysis have recently been growing at a rapid pace. An IEEE Computer Society Workshop on Computer Analysis of Time-Varying Imagery was held in Philadelphia, April 5-6, 1979. A related special issue of the IEEE Transactions on Pattern Anal­ ysis and Machine Intelligence was published in November 1980. The IEEE Com­ puter magazine has also published a special issue on the subject in 1981. The purpose of this book ...

  10. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.; Alkhalifah, Tariq Ali

    2014-01-01

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling

  11. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.

    2014-08-05

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling. If properly imaged, internal multiples (internally scattered energy) can enhance the seismic image. Conventionally, to image internal multiples, accurate, sharp contrasts in the velocity model are required to construct a Green’s function with all the scattered energy. As an alternative, we have developed a generalized internal multiple imaging procedure that images any order internal scattering using the background Green’s function (from the surface to each image point), constructed from a smooth velocity model, usually used for conventional imaging. For the first-order internal multiples, the approach consisted of three steps, in which we first back propagated the recorded surface seismic data using the background Green’s function, then crosscorrelated the back-propagated data with the recorded data, and finally crosscorrelated the result with the original background Green’s function. This procedure images the contribution of the recorded first-order internal multiples, and it is almost free of the single-scattering recorded energy. The cost includes one additional crosscorrelation over the conventional single-scattering imaging application. We generalized this method to image internal multiples of any order separately. The resulting images can be added to the conventional single-scattering image, obtained, e.g., from Kirchhoff or reverse-time migration, to enhance the image. Application to synthetic data with reflectors illuminated by multiple scattering (double scattering) demonstrated the effectiveness of the approach.

  12. Image registration method for medical image sequences

    Science.gov (United States)

    Gee, Timothy F.; Goddard, James S.

    2013-03-26

    Image registration of low contrast image sequences is provided. In one aspect, a desired region of an image is automatically segmented and only the desired region is registered. Active contours and adaptive thresholding of intensity or edge information may be used to segment the desired regions. A transform function is defined to register the segmented region, and sub-pixel information may be determined using one or more interpolation methods.

  13. A New Images Hiding Scheme Based on Chaotic Sequences

    Institute of Scientific and Technical Information of China (English)

    LIU Nian-sheng; GUO Dong-hui; WU Bo-xi; Parr G

    2005-01-01

    We propose a data hidding technique in a still image. This technique is based on chaotic sequence in the transform domain of covert image. We use different chaotic random sequences multiplied by multiple sensitive images, respectively, to spread the spectrum of sensitive images. Multiple sensitive images are hidden in a covert image as a form of noise. The results of theoretical analysis and computer simulation show the new hiding technique have better properties with high security, imperceptibility and capacity for hidden information in comparison with the conventional scheme such as LSB (Least Significance Bit).

  14. An Imaging And Graphics Workstation For Image Sequence Analysis

    Science.gov (United States)

    Mostafavi, Hassan

    1990-01-01

    This paper describes an application-specific engineering workstation designed and developed to analyze imagery sequences from a variety of sources. The system combines the software and hardware environment of the modern graphic-oriented workstations with the digital image acquisition, processing and display techniques. The objective is to achieve automation and high throughput for many data reduction tasks involving metric studies of image sequences. The applications of such an automated data reduction tool include analysis of the trajectory and attitude of aircraft, missile, stores and other flying objects in various flight regimes including launch and separation as well as regular flight maneuvers. The workstation can also be used in an on-line or off-line mode to study three-dimensional motion of aircraft models in simulated flight conditions such as wind tunnels. The system's key features are: 1) Acquisition and storage of image sequences by digitizing real-time video or frames from a film strip; 2) computer-controlled movie loop playback, slow motion and freeze frame display combined with digital image sharpening, noise reduction, contrast enhancement and interactive image magnification; 3) multiple leading edge tracking in addition to object centroids at up to 60 fields per second from both live input video or a stored image sequence; 4) automatic and manual field-of-view and spatial calibration; 5) image sequence data base generation and management, including the measurement data products; 6) off-line analysis software for trajectory plotting and statistical analysis; 7) model-based estimation and tracking of object attitude angles; and 8) interface to a variety of video players and film transport sub-systems.

  15. Heuristics for multiobjective multiple sequence alignment.

    Science.gov (United States)

    Abbasi, Maryam; Paquete, Luís; Pereira, Francisco B

    2016-07-15

    Aligning multiple sequences arises in many tasks in Bioinformatics. However, the alignments produced by the current software packages are highly dependent on the parameters setting, such as the relative importance of opening gaps with respect to the increase of similarity. Choosing only one parameter setting may provide an undesirable bias in further steps of the analysis and give too simplistic interpretations. In this work, we reformulate multiple sequence alignment from a multiobjective point of view. The goal is to generate several sequence alignments that represent a trade-off between maximizing the substitution score and minimizing the number of indels/gaps in the sum-of-pairs score function. This trade-off gives to the practitioner further information about the similarity of the sequences, from which she could analyse and choose the most plausible alignment. We introduce several heuristic approaches, based on local search procedures, that compute a set of sequence alignments, which are representative of the trade-off between the two objectives (substitution score and indels). Several algorithm design options are discussed and analysed, with particular emphasis on the influence of the starting alignment and neighborhood search definitions on the overall performance. A perturbation technique is proposed to improve the local search, which provides a wide range of high-quality alignments. The proposed approach is tested experimentally on a wide range of instances. We performed several experiments with sequences obtained from the benchmark database BAliBASE 3.0. To evaluate the quality of the results, we calculate the hypervolume indicator of the set of score vectors returned by the algorithms. The results obtained allow us to identify reasonably good choices of parameters for our approach. Further, we compared our method in terms of correctly aligned pairs ratio and columns correctly aligned ratio with respect to reference alignments. Experimental results show

  16. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  17. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen; Schuster, Gerard T.

    2017-01-01

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  18. Progressive multiple sequence alignments from triplets

    Directory of Open Access Journals (Sweden)

    Stadler Peter F

    2007-07-01

    Full Text Available Abstract Background The quality of progressive sequence alignments strongly depends on the accuracy of the individual pairwise alignment steps since gaps that are introduced at one step cannot be removed at later aggregation steps. Adjacent insertions and deletions necessarily appear in arbitrary order in pairwise alignments and hence form an unavoidable source of errors. Research Here we present a modified variant of progressive sequence alignments that addresses both issues. Instead of pairwise alignments we use exact dynamic programming to align sequence or profile triples. This avoids a large fractions of the ambiguities arising in pairwise alignments. In the subsequent aggregation steps we follow the logic of the Neighbor-Net algorithm, which constructs a phylogenetic network by step-wisely replacing triples by pairs instead of combining pairs to singletons. To this end the three-way alignments are subdivided into two partial alignments, at which stage all-gap columns are naturally removed. This alleviates the "once a gap, always a gap" problem of progressive alignment procedures. Conclusion The three-way Neighbor-Net based alignment program aln3nn is shown to compare favorably on both protein sequences and nucleic acids sequences to other progressive alignment tools. In the latter case one easily can include scoring terms that consider secondary structure features. Overall, the quality of resulting alignments in general exceeds that of clustalw or other multiple alignments tools even though our software does not included heuristics for context dependent (mismatch scores.

  19. Multiple Segmentation of Image Stacks

    DEFF Research Database (Denmark)

    Smets, Jonathan; Jaeger, Manfred

    2014-01-01

    We propose a method for the simultaneous construction of multiple image segmentations by combining a recently proposed “convolution of mixtures of Gaussians” model with a multi-layer hidden Markov random field structure. The resulting method constructs for a single image several, alternative...

  20. Multiple sequence alignment accuracy and phylogenetic inference.

    Science.gov (United States)

    Ogden, T Heath; Rosenberg, Michael S

    2006-04-01

    Phylogenies are often thought to be more dependent upon the specifics of the sequence alignment rather than on the method of reconstruction. Simulation of sequences containing insertion and deletion events was performed in order to determine the role that alignment accuracy plays during phylogenetic inference. Data sets were simulated for pectinate, balanced, and random tree shapes under different conditions (ultrametric equal branch length, ultrametric random branch length, nonultrametric random branch length). Comparisons between hypothesized alignments and true alignments enabled determination of two measures of alignment accuracy, that of the total data set and that of individual branches. In general, our results indicate that as alignment error increases, topological accuracy decreases. This trend was much more pronounced for data sets derived from more pectinate topologies. In contrast, for balanced, ultrametric, equal branch length tree shapes, alignment inaccuracy had little average effect on tree reconstruction. These conclusions are based on average trends of many analyses under different conditions, and any one specific analysis, independent of the alignment accuracy, may recover very accurate or inaccurate topologies. Maximum likelihood and Bayesian, in general, outperformed neighbor joining and maximum parsimony in terms of tree reconstruction accuracy. Results also indicated that as the length of the branch and of the neighboring branches increase, alignment accuracy decreases, and the length of the neighboring branches is the major factor in topological accuracy. Thus, multiple-sequence alignment can be an important factor in downstream effects on topological reconstruction.

  1. Measuring the distance between multiple sequence alignments.

    Science.gov (United States)

    Blackburne, Benjamin P; Whelan, Simon

    2012-02-15

    Multiple sequence alignment (MSA) is a core method in bioinformatics. The accuracy of such alignments may influence the success of downstream analyses such as phylogenetic inference, protein structure prediction, and functional prediction. The importance of MSA has lead to the proliferation of MSA methods, with different objective functions and heuristics to search for the optimal MSA. Different methods of inferring MSAs produce different results in all but the most trivial cases. By measuring the differences between inferred alignments, we may be able to develop an understanding of how these differences (i) relate to the objective functions and heuristics used in MSA methods, and (ii) affect downstream analyses. We introduce four metrics to compare MSAs, which include the position in a sequence where a gap occurs or the location on a phylogenetic tree where an insertion or deletion (indel) event occurs. We use both real and synthetic data to explore the information given by these metrics and demonstrate how the different metrics in combination can yield more information about MSA methods and the differences between them. MetAl is a free software implementation of these metrics in Haskell. Source and binaries for Windows, Linux and Mac OS X are available from http://kumiho.smith.man.ac.uk/whelan/software/metal/.

  2. Static multiplicities in heterogeneous azeotropic distillation sequences

    DEFF Research Database (Denmark)

    Esbjerg, Klavs; Andersen, Torben Ravn; Jørgensen, Sten Bay

    1998-01-01

    In this paper the results of a bifurcation analysis on heterogeneous azeotropic distillation sequences are given. Two sequences suitable for ethanol dehydration are compared: The 'direct' and the 'indirect' sequence. It is shown, that the two sequences, despite their similarities, exhibit very...... different static behavior. The method of Petlyuk and Avet'yan (1971), Bekiaris et al. (1993), which assumes infinite reflux and infinite number of stages, is extended to and applied on heterogeneous azeotropic distillation sequences. The predictions are substantiated through simulations. The static sequence...

  3. Multiple tag labeling method for DNA sequencing

    Science.gov (United States)

    Mathies, R.A.; Huang, X.C.; Quesada, M.A.

    1995-07-25

    A DNA sequencing method is described which uses single lane or channel electrophoresis. Sequencing fragments are separated in the lane and detected using a laser-excited, confocal fluorescence scanner. Each set of DNA sequencing fragments is separated in the same lane and then distinguished using a binary coding scheme employing only two different fluorescent labels. Also described is a method of using radioisotope labels. 5 figs.

  4. Three-Dimensional Isotropic Fat-Suppressed Proton Density-Weighted MRI at 3 Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging.

    Science.gov (United States)

    Homsi, R; Gieseke, J; Luetkens, J A; Kupczyk, P; Maedler, B; Kukuk, G M; Träber, F; Agha, B; Rauch, M; Rajakaruna, N; Willinek, W; Schild, H H; Hadizadeh, D R

    2016-10-01

    To evaluate whether a 3 D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9 ± 14.5years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40 - 0.63 × 0.44 - 0.89 × 3mm³) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 × 0.68 × 0.63mm³). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging. Fortschr Röntgenstr 2016; 188: 949 - 956. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Lacunary ideal convergence of multiple sequences

    Directory of Open Access Journals (Sweden)

    Bipan Hazarika

    2016-01-01

    Full Text Available An ideal I is a family of subsets of N×N which is closed under taking finite unions and subsets of its elements. In this article, the concept of lacunary ideal convergence of double sequences has been introduced. Also the relation between lacunary ideal convergent and lacunary Cauchy double sequences has been established. Furthermore, the notions of lacunary ideal limit point and lacunary ideal cluster points have been introduced and find the relation between these two notions. Finally, we have studied the properties such as solidity, monotonic.

  6. Multiple Genome Sequences of Lactobacillus plantarum Strains

    OpenAIRE

    Kafka, Thomas A.; Geissler, Andreas J.; Vogel, Rudi F.

    2017-01-01

    ABSTRACT We report here the genome sequences of four Lactobacillus plantarum strains which vary in surface hydrophobicity. Bioinformatic analysis, using additional genomes of Lactobacillus plantarum strains, revealed a possible correlation between the cell wall teichoic acid-type and cell surface hydrophobicity and provide the basis for consecutive analyses.

  7. MANGO: a new approach to multiple sequence alignment.

    Science.gov (United States)

    Zhang, Zefeng; Lin, Hao; Li, Ming

    2007-01-01

    Multiple sequence alignment is a classical and challenging task for biological sequence analysis. The problem is NP-hard. The full dynamic programming takes too much time. The progressive alignment heuristics adopted by most state of the art multiple sequence alignment programs suffer from the 'once a gap, always a gap' phenomenon. Is there a radically new way to do multiple sequence alignment? This paper introduces a novel and orthogonal multiple sequence alignment method, using multiple optimized spaced seeds and new algorithms to handle these seeds efficiently. Our new algorithm processes information of all sequences as a whole, avoiding problems caused by the popular progressive approaches. Because the optimized spaced seeds are provably significantly more sensitive than the consecutive k-mers, the new approach promises to be more accurate and reliable. To validate our new approach, we have implemented MANGO: Multiple Alignment with N Gapped Oligos. Experiments were carried out on large 16S RNA benchmarks showing that MANGO compares favorably, in both accuracy and speed, against state-of-art multiple sequence alignment methods, including ClustalW 1.83, MUSCLE 3.6, MAFFT 5.861, Prob-ConsRNA 1.11, Dialign 2.2.1, DIALIGN-T 0.2.1, T-Coffee 4.85, POA 2.0 and Kalign 2.0.

  8. Diffusion weighted MR imaging in the diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Hagen, T.; Schweigerer-Schroeter, G.; Wellnitz, J.; Wuerstle, T.

    2000-01-01

    Magnetic resonance (MR) imaging is one of the best methods in diagnosis of multiple sclerosis, particularly in disclosure of active demyelinating lesions. Aim of this study was to compare diffusion weighted imaging and contrast enhancement in the detection of active lesions. A MR study with a contrast enhanced T1-weighted pulse sequence with magnetization transfer presaturation and a diffusion weighted echoplanar pulse sequence (b=1000 s/mm 2 ) was performed in 17 patients (11 women, 6 men) with multiple sclerosis. 29 of 239 lesions showed an increased signal intensity in diffusion weighted imaging, 24 lesions a contrast enhancement, but only 16 lesions were visible in both pulse sequences. In patients with short clinical symptomatology significant more lesions could be detected with diffusion-weighted pulse sequence in comparison to patients with long standing symptomatology showing more lesions with contrast enhancement. Hence it is likely, that both pulse sequences detect different histopathologic changes. The early detection of demyelinating lesions in diffusion weighted imaging is attributed to the extracellular edema, however the contrast enhancement is caused by a blood brain barrier abnormality. It can be expected that diffusion weighted imaging will have a high impact on imaging of multiple sclerosis not only in therapeutic trials, but also in clinical routine. (orig.) [de

  9. Image correlation method for DNA sequence alignment.

    Science.gov (United States)

    Curilem Saldías, Millaray; Villarroel Sassarini, Felipe; Muñoz Poblete, Carlos; Vargas Vásquez, Asticio; Maureira Butler, Iván

    2012-01-01

    The complexity of searches and the volume of genomic data make sequence alignment one of bioinformatics most active research areas. New alignment approaches have incorporated digital signal processing techniques. Among these, correlation methods are highly sensitive. This paper proposes a novel sequence alignment method based on 2-dimensional images, where each nucleic acid base is represented as a fixed gray intensity pixel. Query and known database sequences are coded to their pixel representation and sequence alignment is handled as object recognition in a scene problem. Query and database become object and scene, respectively. An image correlation process is carried out in order to search for the best match between them. Given that this procedure can be implemented in an optical correlator, the correlation could eventually be accomplished at light speed. This paper shows an initial research stage where results were "digitally" obtained by simulating an optical correlation of DNA sequences represented as images. A total of 303 queries (variable lengths from 50 to 4500 base pairs) and 100 scenes represented by 100 x 100 images each (in total, one million base pair database) were considered for the image correlation analysis. The results showed that correlations reached very high sensitivity (99.01%), specificity (98.99%) and outperformed BLAST when mutation numbers increased. However, digital correlation processes were hundred times slower than BLAST. We are currently starting an initiative to evaluate the correlation speed process of a real experimental optical correlator. By doing this, we expect to fully exploit optical correlation light properties. As the optical correlator works jointly with the computer, digital algorithms should also be optimized. The results presented in this paper are encouraging and support the study of image correlation methods on sequence alignment.

  10. Identification of Known and Novel Recurrent Viral Sequences in Data from Multiple Patients and Multiple Cancers

    DEFF Research Database (Denmark)

    Friis-Nielsen, Jens; Kjartansdóttir, Kristín Rós; Mollerup, Sarah

    2016-01-01

    have developed a species independent pipeline that utilises sequence clustering for the identification of nucleotide sequences that co-occur across multiple sequencing data instances. We applied the workflow to 686 sequencing libraries from 252 cancer samples of different cancer and tissue types, 32...

  11. Digital image sequence processing, compression, and analysis

    CERN Document Server

    Reed, Todd R

    2004-01-01

    IntroductionTodd R. ReedCONTENT-BASED IMAGE SEQUENCE REPRESENTATIONPedro M. Q. Aguiar, Radu S. Jasinschi, José M. F. Moura, andCharnchai PluempitiwiriyawejTHE COMPUTATION OF MOTIONChristoph Stiller, Sören Kammel, Jan Horn, and Thao DangMOTION ANALYSIS AND DISPLACEMENT ESTIMATION IN THE FREQUENCY DOMAINLuca Lucchese and Guido Maria CortelazzoQUALITY OF SERVICE ASSESSMENT IN NEW GENERATION WIRELESS VIDEO COMMUNICATIONSGaetano GiuntaERROR CONCEALMENT IN DIGITAL VIDEOFrancesco G.B. De NataleIMAGE SEQUENCE RESTORATION: A WIDER PERSPECTIVEAnil KokaramVIDEO SUMMARIZATIONCuneyt M. Taskiran and Edward

  12. Formatt: Correcting protein multiple structural alignments by incorporating sequence alignment

    Directory of Open Access Journals (Sweden)

    Daniels Noah M

    2012-10-01

    Full Text Available Abstract Background The quality of multiple protein structure alignments are usually computed and assessed based on geometric functions of the coordinates of the backbone atoms from the protein chains. These purely geometric methods do not utilize directly protein sequence similarity, and in fact, determining the proper way to incorporate sequence similarity measures into the construction and assessment of protein multiple structure alignments has proved surprisingly difficult. Results We present Formatt, a multiple structure alignment based on the Matt purely geometric multiple structure alignment program, that also takes into account sequence similarity when constructing alignments. We show that Formatt outperforms Matt and other popular structure alignment programs on the popular HOMSTRAD benchmark. For the SABMark twilight zone benchmark set that captures more remote homology, Formatt and Matt outperform other programs; depending on choice of embedded sequence aligner, Formatt produces either better sequence and structural alignments with a smaller core size than Matt, or similarly sized alignments with better sequence similarity, for a small cost in average RMSD. Conclusions Considering sequence information as well as purely geometric information seems to improve quality of multiple structure alignments, though defining what constitutes the best alignment when sequence and structural measures would suggest different alignments remains a difficult open question.

  13. Image sequence analysis workstation for multipoint motion analysis

    Science.gov (United States)

    Mostafavi, Hassan

    1990-08-01

    This paper describes an application-specific engineering workstation designed and developed to analyze motion of objects from video sequences. The system combines the software and hardware environment of a modem graphic-oriented workstation with the digital image acquisition, processing and display techniques. In addition to automation and Increase In throughput of data reduction tasks, the objective of the system Is to provide less invasive methods of measurement by offering the ability to track objects that are more complex than reflective markers. Grey level Image processing and spatial/temporal adaptation of the processing parameters is used for location and tracking of more complex features of objects under uncontrolled lighting and background conditions. The applications of such an automated and noninvasive measurement tool include analysis of the trajectory and attitude of rigid bodies such as human limbs, robots, aircraft in flight, etc. The system's key features are: 1) Acquisition and storage of Image sequences by digitizing and storing real-time video; 2) computer-controlled movie loop playback, freeze frame display, and digital Image enhancement; 3) multiple leading edge tracking in addition to object centroids at up to 60 fields per second from both live input video or a stored Image sequence; 4) model-based estimation and tracking of the six degrees of freedom of a rigid body: 5) field-of-view and spatial calibration: 6) Image sequence and measurement data base management; and 7) offline analysis software for trajectory plotting and statistical analysis.

  14. Realise : reconstruction of reality from image sequences

    NARCIS (Netherlands)

    Leymarie, F.; de la Fortelle, A.; Koenderink, Jan J.; Kappers, A. M L; Stavridi, M.; van Ginneken, B.; Muller, S.; Krake, S.; Faugeras, O.; Robert, L.; Gauclin, C.; Laveau, S.; Zeller, C.; Anon,

    1996-01-01

    REALISE has for principal goals to extract from sequences of images, acquired with a moving camera, information necessary for determining the 3D (CAD-like) structure of a real-life scene together with information about the radiometric signatures of surfaces bounding the extracted 3D objects (e.g.

  15. Statistical processing of large image sequences.

    Science.gov (United States)

    Khellah, F; Fieguth, P; Murray, M J; Allen, M

    2005-01-01

    The dynamic estimation of large-scale stochastic image sequences, as frequently encountered in remote sensing, is important in a variety of scientific applications. However, the size of such images makes conventional dynamic estimation methods, for example, the Kalman and related filters, impractical. In this paper, we present an approach that emulates the Kalman filter, but with considerably reduced computational and storage requirements. Our approach is illustrated in the context of a 512 x 512 image sequence of ocean surface temperature. The static estimation step, the primary contribution here, uses a mixture of stationary models to accurately mimic the effect of a nonstationary prior, simplifying both computational complexity and modeling. Our approach provides an efficient, stable, positive-definite model which is consistent with the given correlation structure. Thus, the methods of this paper may find application in modeling and single-frame estimation.

  16. Automated Registration Of Images From Multiple Sensors

    Science.gov (United States)

    Rignot, Eric J. M.; Kwok, Ronald; Curlander, John C.; Pang, Shirley S. N.

    1994-01-01

    Images of terrain scanned in common by multiple Earth-orbiting remote sensors registered automatically with each other and, where possible, on geographic coordinate grid. Simulated image of terrain viewed by sensor computed from ancillary data, viewing geometry, and mathematical model of physics of imaging. In proposed registration algorithm, simulated and actual sensor images matched by area-correlation technique.

  17. Differential evolution-simulated annealing for multiple sequence alignment

    Science.gov (United States)

    Addawe, R. C.; Addawe, J. M.; Sueño, M. R. K.; Magadia, J. C.

    2017-10-01

    Multiple sequence alignments (MSA) are used in the analysis of molecular evolution and sequence structure relationships. In this paper, a hybrid algorithm, Differential Evolution - Simulated Annealing (DESA) is applied in optimizing multiple sequence alignments (MSAs) based on structural information, non-gaps percentage and totally conserved columns. DESA is a robust algorithm characterized by self-organization, mutation, crossover, and SA-like selection scheme of the strategy parameters. Here, the MSA problem is treated as a multi-objective optimization problem of the hybrid evolutionary algorithm, DESA. Thus, we name the algorithm as DESA-MSA. Simulated sequences and alignments were generated to evaluate the accuracy and efficiency of DESA-MSA using different indel sizes, sequence lengths, deletion rates and insertion rates. The proposed hybrid algorithm obtained acceptable solutions particularly for the MSA problem evaluated based on the three objectives.

  18. Research on hyperspectral dynamic scene and image sequence simulation

    Science.gov (United States)

    Sun, Dandan; Liu, Fang; Gao, Jiaobo; Sun, Kefeng; Hu, Yu; Li, Yu; Xie, Junhu; Zhang, Lei

    2016-10-01

    This paper presents a simulation method of hyperspectral dynamic scene and image sequence for hyperspectral equipment evaluation and target detection algorithm. Because of high spectral resolution, strong band continuity, anti-interference and other advantages, in recent years, hyperspectral imaging technology has been rapidly developed and is widely used in many areas such as optoelectronic target detection, military defense and remote sensing systems. Digital imaging simulation, as a crucial part of hardware in loop simulation, can be applied to testing and evaluation hyperspectral imaging equipment with lower development cost and shorter development period. Meanwhile, visual simulation can produce a lot of original image data under various conditions for hyperspectral image feature extraction and classification algorithm. Based on radiation physic model and material characteristic parameters this paper proposes a generation method of digital scene. By building multiple sensor models under different bands and different bandwidths, hyperspectral scenes in visible, MWIR, LWIR band, with spectral resolution 0.01μm, 0.05μm and 0.1μm have been simulated in this paper. The final dynamic scenes have high real-time and realistic, with frequency up to 100 HZ. By means of saving all the scene gray data in the same viewpoint image sequence is obtained. The analysis results show whether in the infrared band or the visible band, the grayscale variations of simulated hyperspectral images are consistent with the theoretical analysis results.

  19. Selective interferometric imaging of internal multiples

    KAUST Repository

    Zuberi, M. A H

    2013-01-01

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not reproduce such scattering in the Green’s function. If properly imaged, internal multiples (and internally-scattered energy) can enhance the seismic image and illuminate areas otherwise neglected or poorly imaged by conventional single-scattering approaches. Conventionally, in order to image internal multiples, accurate, sharp contrasts in the velocity model are required to construct a Green’s function with all the scattered energy. As an alternative, we develop a three-step procedure, which images the first-order internal scattering using the background Green’s function (from the surface to each image point), constructed from a smooth velocity model: We first back-propagate the recorded surface data using the background Green’s function, then cross-correlate the back-propagated data with the recorded data and finally cross-correlate the result with the original background Green’s function. This procedure images the contribution of the recorded first-order internal multiples and is almost free of the single-scattering recorded energy. This image can be added to the conventional single-scattering image, obtained e.g. from Kirchhoff migration, to enhance the image. Application to synthetic data with reflectors illuminated by multiple scattering only demonstrates the effectiveness of the approach.

  20. Multiple-image oscilloscope camera

    International Nuclear Information System (INIS)

    Yasillo, N.J.

    1978-01-01

    An optical device for placing automatically a plurality of images at selected locations on one film comprises a stepping motor coupled to a rotating mirror and lens. A mechanical connection from the mirror controls an electronic logical system to allow rotation of the mirror to place a focused image at tge desired preselected location. The device is of especial utility when used to place four images on a single film to record oscilloscope views obtained in gamma radiography

  1. MR imaging studies of multiple myeloma in the vertebral column

    International Nuclear Information System (INIS)

    Albert, S.; Leeds, N.E.

    1990-01-01

    This paper studies the sensitivity and characteristics of MR imaging in the diagnosis of myeloma in the vertebral column. The cervical, thoracic, and lumbar spines of 12 patients with known multiple myeloma were imaged with small flip angle, fast gradient-echo, proton-density (FPD) as well as spin-echo T1-weighted, T2-weighted, and intermediate (SE 2,000/20-30) imaging. The FPD images were acquired with pulse sequence gradient recalled acquisition in a steady state at a magnetic field strength of 1.5T with use of a license-plate and a circular surface coil

  2. Optical flow estimation on image sequences with differently exposed frames

    Science.gov (United States)

    Bengtsson, Tomas; McKelvey, Tomas; Lindström, Konstantin

    2015-09-01

    Optical flow (OF) methods are used to estimate dense motion information between consecutive frames in image sequences. In addition to the specific OF estimation method itself, the quality of the input image sequence is of crucial importance to the quality of the resulting flow estimates. For instance, lack of texture in image frames caused by saturation of the camera sensor during exposure can significantly deteriorate the performance. An approach to avoid this negative effect is to use different camera settings when capturing the individual frames. We provide a framework for OF estimation on such sequences that contain differently exposed frames. Information from multiple frames are combined into a total cost functional such that the lack of an active data term for saturated image areas is avoided. Experimental results demonstrate that using alternate camera settings to capture the full dynamic range of an underlying scene can clearly improve the quality of flow estimates. When saturation of image data is significant, the proposed methods show superior performance in terms of lower endpoint errors of the flow vectors compared to a set of baseline methods. Furthermore, we provide some qualitative examples of how and when our method should be used.

  3. Bellerophon: a program to detect chimeric sequences in multiple sequence alignments.

    Science.gov (United States)

    Huber, Thomas; Faulkner, Geoffrey; Hugenholtz, Philip

    2004-09-22

    Bellerophon is a program for detecting chimeric sequences in multiple sequence datasets by an adaption of partial treeing analysis. Bellerophon was specifically developed to detect 16S rRNA gene chimeras in PCR-clone libraries of environmental samples but can be applied to other nucleotide sequence alignments. Bellerophon is available as an interactive web server at http://foo.maths.uq.edu.au/~huber/bellerophon.pl

  4. Reconstruction of ancestral RNA sequences under multiple structural constraints

    OpenAIRE

    Tremblay-Savard, Olivier; Reinharz, Vladimir; Waldisp?hl, J?r?me

    2016-01-01

    Background Secondary structures form the scaffold of multiple sequence alignment of non-coding RNA (ncRNA) families. An accurate reconstruction of ancestral ncRNAs must use this structural signal. However, the inference of ancestors of a single ncRNA family with a single consensus structure may bias the results towards sequences with high affinity to this structure, which are far from the true ancestors. Methods In this paper, we introduce achARNement, a maximum parsimony approach that, given...

  5. Sequence embedding for fast construction of guide trees for multiple sequence alignment

    LENUS (Irish Health Repository)

    Blackshields, Gordon

    2010-05-14

    Abstract Background The most widely used multiple sequence alignment methods require sequences to be clustered as an initial step. Most sequence clustering methods require a full distance matrix to be computed between all pairs of sequences. This requires memory and time proportional to N 2 for N sequences. When N grows larger than 10,000 or so, this becomes increasingly prohibitive and can form a significant barrier to carrying out very large multiple alignments. Results In this paper, we have tested variations on a class of embedding methods that have been designed for clustering large numbers of complex objects where the individual distance calculations are expensive. These methods involve embedding the sequences in a space where the similarities within a set of sequences can be closely approximated without having to compute all pair-wise distances. Conclusions We show how this approach greatly reduces computation time and memory requirements for clustering large numbers of sequences and demonstrate the quality of the clusterings by benchmarking them as guide trees for multiple alignment. Source code is available for download from http:\\/\\/www.clustal.org\\/mbed.tgz.

  6. PET imaging in multiple sclerosis

    NARCIS (Netherlands)

    Faria, Daniele de Paula; Copray, Sjef; Buchpiguel, Carlos; Dierckx, Rudi; de Vries, Erik

    Positron emission tomography (PET) is a non-invasive technique for quantitative imaging of biochemical and physiological processes in animals and humans. PET uses probes labeled with a radioactive isotope, called PET tracers, which can bind to or be converted by a specific biological target and thus

  7. Heuristic for Solving the Multiple Alignment Sequence Problem

    Directory of Open Access Journals (Sweden)

    Roman Anselmo Mora Gutiérrez

    2011-03-01

    Full Text Available In this paper we developed a new algorithm for solving the problem of multiple sequence alignment (AM S, which is a hybrid metaheuristic based on harmony search and simulated annealing. The hybrid was validated with the methodology of Julie Thompson. This is a basic algorithm and and results obtained during this stage are encouraging.

  8. Multimodality imaging features of hereditary multiple exostoses

    OpenAIRE

    Kok, H K; Fitzgerald, L; Campbell, N; Lyburn, I D; Munk, P L; Buckley, O; Torreggiani, W C

    2013-01-01

    Hereditary multiple exostoses (HME) or diaphyseal aclasis is an inherited disorder characterised by the formation of multiple osteochondromas, which are cartilage-capped osseous outgrowths, and the development of associated osseous deformities. Individuals with HME may be asymptomatic or develop clinical symptoms, which prompt imaging studies. Different modalities ranging from plain radiographs to cross-sectional and nuclear medicine imaging studies can be helpful in the diagnosis and detecti...

  9. Multiple Image Radiography With Diffraction Enhanced Imaging For Breast Specimen

    International Nuclear Information System (INIS)

    Oltulu, Oral; Zhong Zhong; Hasnah, Moumen; Chapman, Dean

    2007-01-01

    Biological samples are of great interest for many imaging techniques. The samples usually contain small structures and weak absorption properties. The combinations of weak signals with overlying structures make feature recognition difficult in many cases. In the x-ray regime, a relatively new imaging technique Diffraction Enhanced Imaging (DEI) has superior tissue contrast over conventional radiography and is proven to be very sensitive method. Multiple images taken by DEI are called Multiple Image Radiography (MIR). The purpose of this study is to validate the potential application of the method and to show that MIR-DEI method may give more information about the sample

  10. Multiplicative calculus in biomedical image analysis

    NARCIS (Netherlands)

    Florack, L.M.J.; Assen, van H.C.

    2011-01-01

    We advocate the use of an alternative calculus in biomedical image analysis, known as multiplicative (a.k.a. non-Newtonian) calculus. It provides a natural framework in problems in which positive images or positive definite matrix fields and positivity preserving operators are of interest. Indeed,

  11. Genomic multiple sequence alignments: refinement using a genetic algorithm

    Directory of Open Access Journals (Sweden)

    Lefkowitz Elliot J

    2005-08-01

    Full Text Available Abstract Background Genomic sequence data cannot be fully appreciated in isolation. Comparative genomics – the practice of comparing genomic sequences from different species – plays an increasingly important role in understanding the genotypic differences between species that result in phenotypic differences as well as in revealing patterns of evolutionary relationships. One of the major challenges in comparative genomics is producing a high-quality alignment between two or more related genomic sequences. In recent years, a number of tools have been developed for aligning large genomic sequences. Most utilize heuristic strategies to identify a series of strong sequence similarities, which are then used as anchors to align the regions between the anchor points. The resulting alignment is globally correct, but in many cases is suboptimal locally. We describe a new program, GenAlignRefine, which improves the overall quality of global multiple alignments by using a genetic algorithm to improve local regions of alignment. Regions of low quality are identified, realigned using the program T-Coffee, and then refined using a genetic algorithm. Because a better COFFEE (Consistency based Objective Function For alignmEnt Evaluation score generally reflects greater alignment quality, the algorithm searches for an alignment that yields a better COFFEE score. To improve the intrinsic slowness of the genetic algorithm, GenAlignRefine was implemented as a parallel, cluster-based program. Results We tested the GenAlignRefine algorithm by running it on a Linux cluster to refine sequences from a simulation, as well as refine a multiple alignment of 15 Orthopoxvirus genomic sequences approximately 260,000 nucleotides in length that initially had been aligned by Multi-LAGAN. It took approximately 150 minutes for a 40-processor Linux cluster to optimize some 200 fuzzy (poorly aligned regions of the orthopoxvirus alignment. Overall sequence identity increased only

  12. A time warping approach to multiple sequence alignment.

    Science.gov (United States)

    Arribas-Gil, Ana; Matias, Catherine

    2017-04-25

    We propose an approach for multiple sequence alignment (MSA) derived from the dynamic time warping viewpoint and recent techniques of curve synchronization developed in the context of functional data analysis. Starting from pairwise alignments of all the sequences (viewed as paths in a certain space), we construct a median path that represents the MSA we are looking for. We establish a proof of concept that our method could be an interesting ingredient to include into refined MSA techniques. We present a simple synthetic experiment as well as the study of a benchmark dataset, together with comparisons with 2 widely used MSA softwares.

  13. Secure image retrieval with multiple keys

    Science.gov (United States)

    Liang, Haihua; Zhang, Xinpeng; Wei, Qiuhan; Cheng, Hang

    2018-03-01

    This article proposes a secure image retrieval scheme under a multiuser scenario. In this scheme, the owner first encrypts and uploads images and their corresponding features to the cloud; then, the user submits the encrypted feature of the query image to the cloud; next, the cloud compares the encrypted features and returns encrypted images with similar content to the user. To find the nearest neighbor in the encrypted features, an encryption with multiple keys is proposed, in which the query feature of each user is encrypted by his/her own key. To improve the key security and space utilization, global optimization and Gaussian distribution are, respectively, employed to generate multiple keys. The experiments show that the proposed encryption can provide effective and secure image retrieval for each user and ensure confidentiality of the query feature of each user.

  14. Identification of Known and Novel Recurrent Viral Sequences in Data from Multiple Patients and Multiple Cancers

    DEFF Research Database (Denmark)

    Friis-Nielsen, Jens; Kjartansdóttir, Kristín Rós; Mollerup, Sarah

    2016-01-01

    non-template controls, and 24 test samples. Recurrent sequences were statistically associated to biological, methodological or technical features with the aim to identify novel pathogens or plausible contaminants that may associate to a particular kit or method. We provide examples of identified......Virus discovery from high throughput sequencing data often follows a bottom-up approach where taxonomic annotation takes place prior to association to disease. Albeit effective in some cases, the approach fails to detect novel pathogens and remote variants not present in reference databases. We...... have developed a species independent pipeline that utilises sequence clustering for the identification of nucleotide sequences that co-occur across multiple sequencing data instances. We applied the workflow to 686 sequencing libraries from 252 cancer samples of different cancer and tissue types, 32...

  15. Improved nonparametric inference for multiple correlated periodic sequences

    KAUST Repository

    Sun, Ying

    2013-08-26

    This paper proposes a cross-validation method for estimating the period as well as the values of multiple correlated periodic sequences when data are observed at evenly spaced time points. The period of interest is estimated conditional on the other correlated sequences. An alternative method for period estimation based on Akaike\\'s information criterion is also discussed. The improvement of the period estimation performance is investigated both theoretically and by simulation. We apply the multivariate cross-validation method to the temperature data obtained from multiple ice cores, investigating the periodicity of the El Niño effect. Our methodology is also illustrated by estimating patients\\' cardiac cycle from different physiological signals, including arterial blood pressure, electrocardiography, and fingertip plethysmograph.

  16. MACSIMS : multiple alignment of complete sequences information management system

    Directory of Open Access Journals (Sweden)

    Plewniak Frédéric

    2006-06-01

    Full Text Available Abstract Background In the post-genomic era, systems-level studies are being performed that seek to explain complex biological systems by integrating diverse resources from fields such as genomics, proteomics or transcriptomics. New information management systems are now needed for the collection, validation and analysis of the vast amount of heterogeneous data available. Multiple alignments of complete sequences provide an ideal environment for the integration of this information in the context of the protein family. Results MACSIMS is a multiple alignment-based information management program that combines the advantages of both knowledge-based and ab initio sequence analysis methods. Structural and functional information is retrieved automatically from the public databases. In the multiple alignment, homologous regions are identified and the retrieved data is evaluated and propagated from known to unknown sequences with these reliable regions. In a large-scale evaluation, the specificity of the propagated sequence features is estimated to be >99%, i.e. very few false positive predictions are made. MACSIMS is then used to characterise mutations in a test set of 100 proteins that are known to be involved in human genetic diseases. The number of sequence features associated with these proteins was increased by 60%, compared to the features available in the public databases. An XML format output file allows automatic parsing of the MACSIM results, while a graphical display using the JalView program allows manual analysis. Conclusion MACSIMS is a new information management system that incorporates detailed analyses of protein families at the structural, functional and evolutionary levels. MACSIMS thus provides a unique environment that facilitates knowledge extraction and the presentation of the most pertinent information to the biologist. A web server and the source code are available at http://bips.u-strasbg.fr/MACSIMS/.

  17. Skeleton-based human action recognition using multiple sequence alignment

    Science.gov (United States)

    Ding, Wenwen; Liu, Kai; Cheng, Fei; Zhang, Jin; Li, YunSong

    2015-05-01

    Human action recognition and analysis is an active research topic in computer vision for many years. This paper presents a method to represent human actions based on trajectories consisting of 3D joint positions. This method first decompose action into a sequence of meaningful atomic actions (actionlets), and then label actionlets with English alphabets according to the Davies-Bouldin index value. Therefore, an action can be represented using a sequence of actionlet symbols, which will preserve the temporal order of occurrence of each of the actionlets. Finally, we employ sequence comparison to classify multiple actions through using string matching algorithms (Needleman-Wunsch). The effectiveness of the proposed method is evaluated on datasets captured by commodity depth cameras. Experiments of the proposed method on three challenging 3D action datasets show promising results.

  18. MUSCLE: multiple sequence alignment with high accuracy and high throughput.

    Science.gov (United States)

    Edgar, Robert C

    2004-01-01

    We describe MUSCLE, a new computer program for creating multiple alignments of protein sequences. Elements of the algorithm include fast distance estimation using kmer counting, progressive alignment using a new profile function we call the log-expectation score, and refinement using tree-dependent restricted partitioning. The speed and accuracy of MUSCLE are compared with T-Coffee, MAFFT and CLUSTALW on four test sets of reference alignments: BAliBASE, SABmark, SMART and a new benchmark, PREFAB. MUSCLE achieves the highest, or joint highest, rank in accuracy on each of these sets. Without refinement, MUSCLE achieves average accuracy statistically indistinguishable from T-Coffee and MAFFT, and is the fastest of the tested methods for large numbers of sequences, aligning 5000 sequences of average length 350 in 7 min on a current desktop computer. The MUSCLE program, source code and PREFAB test data are freely available at http://www.drive5. com/muscle.

  19. Correlations of pseudo-random numbers of multiplicative sequence

    International Nuclear Information System (INIS)

    Bukin, A.D.

    1989-01-01

    An algorithm is suggested for searching with a computer in unit n-dimensional cube the sets of planes where all the points fall whose coordinates are composed of n successive pseudo-random numbers of multiplicative sequence. This effect should be taken into account in Monte-Carlo calculations with definite constructive dimension. The parameters of these planes are obtained for three random number generators. 2 refs.; 2 tabs

  20. Eigenimage filtering of nuclear medicine image sequences

    International Nuclear Information System (INIS)

    Windham, J.P.; Froelich, J.W.; Abd-Allah, M.

    1985-01-01

    In many nuclear medicine imaging sequences the localization of radioactivity in organs other than the target organ interferes with imaging of the desired anatomical structure or physiological process. A filtering technique has been developed which suppresses the interfering process while enhancing the desired process. This technique requires the identification of temporal sequential signatures for both the interfering and desired processes. These signatures are placed in the form of signature vectors. Signature matrices, M/sub D/ and M/sub U/, are formed by taking the outer product expansion of the temporal signature vectors for the desired and interfering processes respectively. By using the transformation from the simultaneous diagonalization of these two signature matrices a weighting vector is obtained. The technique is shown to maximize the projection of the desired process while minimizing the interfering process based upon an extension of Rayleigh's Principle. The technique is demonstrated for first pass renal and cardiac flow studies. This filter offers a potential for simplifying and extending the accuracy of diagnostic nuclear medicine procedures

  1. A typical MR imaging of multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Katagiri, Shinako; Kan, Shinichi; Ikeda, Toshiaki; Nishiyama, Syougo; Nishimaki, Hiroshi; Matsubayashi, Takashi; Hata, Takashi [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1995-06-01

    MR imaging is very useful in detecting the intracranial lesion of multiple sclerosis (MS). We present six patients of MS with atypical MR imaging findings. Six patients aged 27-56 years (mean 36 years), and sexuality of six patients were 2 men and 4 females. Three patient`s clinical course had episodes of optic neuritis. The plaque`s size of the predominant lesion of the patients ranged from 3.0 to 9.0 cm in diameter. The plaques were oval, elliptically and other shaped. At acute stage, MR imaging detected perfocal edema and focal mass effect in three cases of our study. Two out of six cases showed multiple irregularly enhancing lesion with Gadolinium-DTPA. Plaques of all cases did not disappear completely in final MR imaging study. (author).

  2. A typical MR imaging of multiple sclerosis

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Kan, Shinichi; Ikeda, Toshiaki; Nishiyama, Syougo; Nishimaki, Hiroshi; Matsubayashi, Takashi; Hata, Takashi

    1995-01-01

    MR imaging is very useful in detecting the intracranial lesion of multiple sclerosis (MS). We present six patients of MS with atypical MR imaging findings. Six patients aged 27-56 years (mean 36 years), and sexuality of six patients were 2 men and 4 females. Three patient's clinical course had episodes of optic neuritis. The plaque's size of the predominant lesion of the patients ranged from 3.0 to 9.0 cm in diameter. The plaques were oval, elliptically and other shaped. At acute stage, MR imaging detected perfocal edema and focal mass effect in three cases of our study. Two out of six cases showed multiple irregularly enhancing lesion with Gadolinium-DTPA. Plaques of all cases did not disappear completely in final MR imaging study. (author)

  3. Attenuation of multiples in image space

    Science.gov (United States)

    Alvarez, Gabriel F.

    In complex subsurface areas, attenuation of 3D specular and diffracted multiples in data space is difficult and inaccurate. In those areas, image space is an attractive alternative. There are several reasons: (1) migration increases the signal-to-noise ratio of the data; (2) primaries are mapped to coherent events in Subsurface Offset Domain Common Image Gathers (SODCIGs) or Angle Domain Common Image Gathers (ADCIGs); (3) image space is regular and smaller; (4) attenuating the multiples in data space leaves holes in the frequency-Wavenumber space that generate artifacts after migration. I develop a new equation for the residual moveout of specular multiples in ADCIGs and use it for the kernel of an apex-shifted Radon transform to focus and separate the primaries from specular and diffracted multiples. Because of small amplitude, phase and kinematic errors in the multiple estimate, we need adaptive matching and subtraction to estimate the primaries. I pose this problem as an iterative least-squares inversion that simultaneously matches the estimates of primaries and multiples to the data. Standard methods match only the estimate of the multiples. I demonstrate with real and synthetic data that the method produces primaries and multiples with little cross-talk. In 3D, the multiples exhibit residual moveout in SODCIGs in in-line and cross-line offsets. They map away from zero subsurface offsets when migrated with the faster velocity of the primaries. In ADCIGs the residual moveout of the primaries as a function of the aperture angle, for a given azimuth, is flat for those angles that illuminate the reflector. The multiples have residual moveout towards increasing depth for increasing aperture angles at all azimuths. As a function of azimuth, the primaries have better azimuth resolution than the multiples at larger aperture angles. I show, with a real 3D dataset, that even below salt, where illumination is poor, the multiples are well attenuated in ADCIGs with the new

  4. Free Surface Downgoing VSP Multiple Imaging

    Science.gov (United States)

    Maula, Fahdi; Dac, Nguyen

    2018-03-01

    The common usage of a vertical seismic profile is to capture the reflection wavefield (upgoing wavefield) so that it can be used for further well tie or other interpretations. Borehole Seismic (VSP) receivers capture the reflection from below the well trajectory, traditionally no seismic image information above trajectory. The non-traditional way of processing the VSP multiple can be used to expand the imaging above the well trajectory. This paper presents the case study of using VSP downgoing multiples for further non-traditional imaging applications. In general, VSP processing, upgoing and downgoing arrivals are separated during processing. The up-going wavefield is used for subsurface illumination, whereas the downgoing wavefield and multiples are normally excluded from the processing. In a situation where the downgoing wavefield passes the reflectors several times (multiple), the downgoing wavefield carries reflection information. Its benefit is that it can be used for seismic tie up to seabed, and possibility for shallow hazards identifications. One of the concepts of downgoing imaging is widely known as mirror-imaging technique. This paper presents a case study from deep water offshore Vietnam. The case study is presented to demonstrate the robustness of the technique, and the limitations encountered during its processing.

  5. Magnetic resonance imaging abnormalities in multiple sclerosis: A review

    International Nuclear Information System (INIS)

    Saharian, M. A.; Shakaouri Rad, A.; Motamedi, M.; Pakdaman, H.; Radue, E. W.

    2007-01-01

    :During the last two decades, magnetic resonance imaging has been widely used In the diagnosis and treatment monitoring of multiple sclerosis. MRI, both conventional and non conventional methods, has transformed all aspects of M S research and clinical practice in recent years. Although advanced imaging methods have added much more to our knowledge about pathogenesis and natural history of the disease but their cost, availability, complexity and lack of validation have limited their use in routine clinical practice. Conventional MR techniques including proton density, T1/T2-Weighted images and fluid- attenuated inversion recovery sequences are now accepted in standard protocols for diagnosis and treatment outcome measures in clinical trials of multiple sclerosis. This review will focus on the type, morphology and evolution of M S lesions regarding conventional MRI and their use for treatment monitoring in daily clinical practice

  6. Interesting images: Multiple coronary artery aneurysms.

    Science.gov (United States)

    Howard, Jonathon M; Viswanath, Omar; Armas, Alfredo; Santana, Orlando; Rosen, Gerald P

    2017-01-01

    We present the case of a 65-year-old male who presented with stable angina and dyspnea on exertion. His initial workup yielded a positive treadmill stress test for reversible apical ischemia, and transthoracic echocardiogram demonstrated impaired systolic function. Cardiac catheterization was then performed, revealing severe atherosclerotic disease including multiple coronary artery aneurysms. As a result, the patient was advised to and subsequently underwent a coronary artery bypass graft. This case highlights the presence of multiple coronary artery aneurysms and the ability to appreciate these pathologic findings on multiple imaging modalities, including coronary angiogram, transesophageal echocardiography, and direct visualization through the surgical field.

  7. Optimized, unequal pulse spacing in multiple echo sequences improves refocusing in magnetic resonance.

    Science.gov (United States)

    Jenista, Elizabeth R; Stokes, Ashley M; Branca, Rosa Tamara; Warren, Warren S

    2009-11-28

    A recent quantum computing paper (G. S. Uhrig, Phys. Rev. Lett. 98, 100504 (2007)) analytically derived optimal pulse spacings for a multiple spin echo sequence designed to remove decoherence in a two-level system coupled to a bath. The spacings in what has been called a "Uhrig dynamic decoupling (UDD) sequence" differ dramatically from the conventional, equal pulse spacing of a Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo sequence. The UDD sequence was derived for a model that is unrelated to magnetic resonance, but was recently shown theoretically to be more general. Here we show that the UDD sequence has theoretical advantages for magnetic resonance imaging of structured materials such as tissue, where diffusion in compartmentalized and microstructured environments leads to fluctuating fields on a range of different time scales. We also show experimentally, both in excised tissue and in a live mouse tumor model, that optimal UDD sequences produce different T(2)-weighted contrast than do CPMG sequences with the same number of pulses and total delay, with substantial enhancements in most regions. This permits improved characterization of low-frequency spectral density functions in a wide range of applications.

  8. Pulse sequences for contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Graves, Martin J.

    2007-01-01

    The theory and application of magnetic resonance imaging (MRI) pulse sequences following the administration of an exogenous contrast agent are discussed. Pulse sequences are categorised according to the contrast agent mechanism: changes in proton density, relaxivity, magnetic susceptibility and resonant frequency shift. Applications in morphological imaging, magnetic resonance angiography, dynamic imaging and cell labelling are described. The importance of optimising the pulse sequence for each application is emphasised

  9. In vivo quantitative NMR imaging of fruit tissues during growth using Spoiled Gradient Echo sequence

    DEFF Research Database (Denmark)

    Kenouche, S.; Perrier, M.; Bertin, N.

    2014-01-01

    of this study was to design a robust and accurate quantitative measurement method based on NMR imaging combined with contrast agent (CA) for mapping and quantifying water transport in growing cherry tomato fruits. A multiple flip-angle Spoiled Gradient Echo (SGE) imaging sequence was used to evaluate...

  10. High Dynamic Range Imaging Using Multiple Exposures

    Science.gov (United States)

    Hou, Xinglin; Luo, Haibo; Zhou, Peipei; Zhou, Wei

    2017-06-01

    It is challenging to capture a high-dynamic range (HDR) scene using a low-dynamic range (LDR) camera. This paper presents an approach for improving the dynamic range of cameras by using multiple exposure images of same scene taken under different exposure times. First, the camera response function (CRF) is recovered by solving a high-order polynomial in which only the ratios of the exposures are used. Then, the HDR radiance image is reconstructed by weighted summation of the each radiance maps. After that, a novel local tone mapping (TM) operator is proposed for the display of the HDR radiance image. By solving the high-order polynomial, the CRF can be recovered quickly and easily. Taken the local image feature and characteristic of histogram statics into consideration, the proposed TM operator could preserve the local details efficiently. Experimental result demonstrates the effectiveness of our method. By comparison, the method outperforms other methods in terms of imaging quality.

  11. IVisTMSA: Interactive Visual Tools for Multiple Sequence Alignments.

    Science.gov (United States)

    Pervez, Muhammad Tariq; Babar, Masroor Ellahi; Nadeem, Asif; Aslam, Naeem; Naveed, Nasir; Ahmad, Sarfraz; Muhammad, Shah; Qadri, Salman; Shahid, Muhammad; Hussain, Tanveer; Javed, Maryam

    2015-01-01

    IVisTMSA is a software package of seven graphical tools for multiple sequence alignments. MSApad is an editing and analysis tool. It can load 409% more data than Jalview, STRAP, CINEMA, and Base-by-Base. MSA comparator allows the user to visualize consistent and inconsistent regions of reference and test alignments of more than 21-MB size in less than 12 seconds. MSA comparator is 5,200% efficient and more than 40% efficient as compared to BALiBASE c program and FastSP, respectively. MSA reconstruction tool provides graphical user interfaces for four popular aligners and allows the user to load several sequence files at a time. FASTA generator converts seven formats of alignments of unlimited size into FASTA format in a few seconds. MSA ID calculator calculates identity matrix of more than 11,000 sequences with a sequence length of 2,696 base pairs in less than 100 seconds. Tree and Distance Matrix calculation tools generate phylogenetic tree and distance matrix, respectively, using neighbor joining% identity and BLOSUM 62 matrix.

  12. Reconstruction of ancestral RNA sequences under multiple structural constraints

    Directory of Open Access Journals (Sweden)

    Olivier Tremblay-Savard

    2016-11-01

    Full Text Available Abstract Background Secondary structures form the scaffold of multiple sequence alignment of non-coding RNA (ncRNA families. An accurate reconstruction of ancestral ncRNAs must use this structural signal. However, the inference of ancestors of a single ncRNA family with a single consensus structure may bias the results towards sequences with high affinity to this structure, which are far from the true ancestors. Methods In this paper, we introduce achARNement, a maximum parsimony approach that, given two alignments of homologous ncRNA families with consensus secondary structures and a phylogenetic tree, simultaneously calculates ancestral RNA sequences for these two families. Results We test our methodology on simulated data sets, and show that achARNement outperforms classical maximum parsimony approaches in terms of accuracy, but also reduces by several orders of magnitude the number of candidate sequences. To conclude this study, we apply our algorithms on the Glm clan and the FinP-traJ clan from the Rfam database. Conclusions Our results show that our methods reconstruct small sets of high-quality candidate ancestors with better agreement to the two target structures than with classical approaches. Our program is freely available at: http://csb.cs.mcgill.ca/acharnement .

  13. Noisy: Identification of problematic columns in multiple sequence alignments

    Directory of Open Access Journals (Sweden)

    Grünewald Stefan

    2008-06-01

    Full Text Available Abstract Motivation Sequence-based methods for phylogenetic reconstruction from (nucleic acid sequence data are notoriously plagued by two effects: homoplasies and alignment errors. Large evolutionary distances imply a large number of homoplastic sites. As most protein-coding genes show dramatic variations in substitution rates that are not uncorrelated across the sequence, this often leads to a patchwork pattern of (i phylogenetically informative and (ii effectively randomized regions. In highly variable regions, furthermore, alignment errors accumulate resulting in sometimes misleading signals in phylogenetic reconstruction. Results We present here a method that, based on assessing the distribution of character states along a cyclic ordering of the taxa, allows the identification of phylogenetically uninformative homoplastic sites in a multiple sequence alignment. Removal of these sites appears to improve the performance of phylogenetic reconstruction algorithms as measured by various indices of "tree quality". In particular, we obtain more stable trees due to the exclusion of phylogenetically incompatible sites that most likely represent strongly randomized characters. Software The computer program noisy implements this approach. It can be employed to improving phylogenetic reconstruction capability with quite a considerable success rate whenever (1 the average bootstrap support obtained from the original alignment is low, and (2 there are sufficiently many taxa in the data set – at least, say, 12 to 15 taxa. The software can be obtained under the GNU Public License from http://www.bioinf.uni-leipzig.de/Software/noisy/.

  14. Reconstruction of ancestral RNA sequences under multiple structural constraints.

    Science.gov (United States)

    Tremblay-Savard, Olivier; Reinharz, Vladimir; Waldispühl, Jérôme

    2016-11-11

    Secondary structures form the scaffold of multiple sequence alignment of non-coding RNA (ncRNA) families. An accurate reconstruction of ancestral ncRNAs must use this structural signal. However, the inference of ancestors of a single ncRNA family with a single consensus structure may bias the results towards sequences with high affinity to this structure, which are far from the true ancestors. In this paper, we introduce achARNement, a maximum parsimony approach that, given two alignments of homologous ncRNA families with consensus secondary structures and a phylogenetic tree, simultaneously calculates ancestral RNA sequences for these two families. We test our methodology on simulated data sets, and show that achARNement outperforms classical maximum parsimony approaches in terms of accuracy, but also reduces by several orders of magnitude the number of candidate sequences. To conclude this study, we apply our algorithms on the Glm clan and the FinP-traJ clan from the Rfam database. Our results show that our methods reconstruct small sets of high-quality candidate ancestors with better agreement to the two target structures than with classical approaches. Our program is freely available at: http://csb.cs.mcgill.ca/acharnement .

  15. Three-dimensional isotropic fat-suppressed proton density-weighted MRI at 3 tesla using a T/R-coil can replace multiple plane two-dimensional sequences in knee imaging

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A. [Bonn Univ. (Germany). Dept. of Radiology; Gieseke, J. [Philips Healthcare, Hamburg (Germany); and others

    2016-10-15

    To evaluate whether a 3D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9±14.5 years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40-0.63 x 0.44-0.89 x 3 mm{sup 3}) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 x 0.68 x 0.63 mm{sup 3}). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p<0.01 for ACL and PCL; p=0.07 for MEN). Compared to 2D images, the OIQ was rated higher in 3D-PDwFS images (p<0.01) due to fewer artifacts and HFS despite the lower IS (p<0.01). The sensitivity and specificity of lesion detection in 3D- and 2D-PDwFS were similar. Compared to standard multiplanar 2D-PDwFS knee imaging, isotropic high spatial resolution 3D-PDwFS of the knee at 3.0T can be acquired with high image quality in a reasonable scan time. Multiplanar reformations in arbitrary planes may serve as an additional benefit of 3D-PDwFS.

  16. Magnetic resonance imaging in multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Aotsuka, Akiyo; Shinotoh, Hitoshi; Hirayama, Keizo [Chiba Univ. (Japan). School of Medicine; Ikehira, Hiroo; Hashimoto, Takahiro

    1992-08-01

    We studied 18 patients with multiple system atrophy (MSA) by high field strength MRI: 6 striatonigral degeneration (SND), 4 Shy-Drager syndrome (SDS), and 8 olivo-ponto-cerebellar atrophy (OPCA). We also studied 30 Parkinson's disease (PD) and 10 age-matched controls. The diagnosis of SND, SDS, and OPCA were based on criteria after Hirayama et al (1985). Bradykinesia, rigidity, and tremor were assessed with the summed scores of the signs used as the extrapyramidal scores. The mean extrapyramidal scores were not significantly different in patients with SND, SDS, OPCA, and PD. MRI studies were performed on 1.5 tesla MRI unit, using a T[sub 2]-weighted spin echo pulse sequence (TR2500 ms/TE40 ms). The width of the pars compacta signal in all subjects was measured by the method of Duguid et al (1986). Intensity profiles were made on a straight line perpendicular to the pars compacta through the center of the red nucleus on an image of the midbrain. We measured the width of the valley at half-height between the peaks of an index of the width of the pars compacta signal. The mean widths of the pars compacta signal were: 2.8[+-]0.4 mm (SND), 2.8[+-]0.7 mm (SDS), 3.6[+-]0.6 mm (OPCA), 2.7[+-]0.3 mm (PD), and 4.3[+-]0.6 mm (control). The mean widths of the pars compacta signal in PD, SND, and SDS were significantly narrower than that in the control group (p<0.05), while the OPCA group was not significantly narrower. The results may indicate that the time course of nigral involvement is milder in OPCA than in SND and SDS. The extrapyramidal signs in OPCA may be attributed mainly to the degeneration of the putamen rather than to that of the substantia nigra. Abnormal hypointensity in the posterolateral putamen was found in only one SND patient and in two OPCA patients, even though this finding has been frequently observed in MSA. Since no PD patients exhibited this finding, it may of some value in differentiating MSA from PD. (author).

  17. Optimal update with multiple out-of-sequence measurements

    Science.gov (United States)

    Zhang, Shuo; Bar-Shalom, Yaakov

    2011-06-01

    In multisensor target tracking systems receiving out-of-sequence measurements from local sensors is a common situation. In the last decade many algorithms have been proposed to update a target state with an OOSM optimally or suboptimally. However, what one faces in the real world is multiple OOSMs, which arrive at the fusion center in, generally, arbitrary orders, e.g., in succession or interleaved with in-sequence measurements. A straightforward approach to deal with this multi-OOSM problem is by sequentially applying a given OOSM algorithm; however, this simple solution does not guarantee optimal update under the multi-OOSM scenario. The present paper discusses the differences between the single-OOSM processing and the multi-OOSM processing, and presents the general solution to the multi-OOSM problem, called the complete in-sequence information (CISI) approach. Given an OOSM, in addition to updating the target state at the most recent time, the CISI approach also updates the states between the OOSM time and the most recent time, including the state at the OOSM time. Three novel CISI methods are developed in this paper: the information filter-equivalent measurement (IF-EqM) method, the CISI fixed-point smoothing (CISI-FPS) method and the CISI fixed-interval smoothing (CISI-FIS) method. Numerical examples are given to show the optimality of these CISI methods under various multi-OOSM scenarios.

  18. Programmable pulse sequence generator with multiple output lines

    Science.gov (United States)

    Drabczyk, Hubert

    2006-10-01

    This paper presents a novel concept of pulse sequence generator and its prototype as an electronic circuit testing laboratory tool. The generator has multiple output lines and is capable of using control data defining different pulse sequences to be given to the outputs. It is also possible to use different voltage levels in output signal and switch output lines for reading data from driven system. The pulse sequence generator can be used for runtime environment simulation, as hardware tester or auxiliary tool in new designs. Important design factors were to keep cost of the tool low and allow integration with other projects by using flexible architecture. The prototype was based on universal programmer with adjustable power supply, '51 microcontroller and Altera Cyclone chip. The generator communicates witch PC computer via RS232 port. Dedicated software was developed in the course of this project, to control the tool and data transmission. The prototype confirmed the possibility to create an inexpensive multipurpose laboratory tool for programming, testing and simulation of digital devices.

  19. Using hidden Markov models to align multiple sequences.

    Science.gov (United States)

    Mount, David W

    2009-07-01

    A hidden Markov model (HMM) is a probabilistic model of a multiple sequence alignment (msa) of proteins. In the model, each column of symbols in the alignment is represented by a frequency distribution of the symbols (called a "state"), and insertions and deletions are represented by other states. One moves through the model along a particular path from state to state in a Markov chain (i.e., random choice of next move), trying to match a given sequence. The next matching symbol is chosen from each state, recording its probability (frequency) and also the probability of going to that state from a previous one (the transition probability). State and transition probabilities are multiplied to obtain a probability of the given sequence. The hidden nature of the HMM is due to the lack of information about the value of a specific state, which is instead represented by a probability distribution over all possible values. This article discusses the advantages and disadvantages of HMMs in msa and presents algorithms for calculating an HMM and the conditions for producing the best HMM.

  20. MSAViewer: interactive JavaScript visualization of multiple sequence alignments.

    Science.gov (United States)

    Yachdav, Guy; Wilzbach, Sebastian; Rauscher, Benedikt; Sheridan, Robert; Sillitoe, Ian; Procter, James; Lewis, Suzanna E; Rost, Burkhard; Goldberg, Tatyana

    2016-11-15

    The MSAViewer is a quick and easy visualization and analysis JavaScript component for Multiple Sequence Alignment data of any size. Core features include interactive navigation through the alignment, application of popular color schemes, sorting, selecting and filtering. The MSAViewer is 'web ready': written entirely in JavaScript, compatible with modern web browsers and does not require any specialized software. The MSAViewer is part of the BioJS collection of components. The MSAViewer is released as open source software under the Boost Software License 1.0. Documentation, source code and the viewer are available at http://msa.biojs.net/Supplementary information: Supplementary data are available at Bioinformatics online. msa@bio.sh. © The Author 2016. Published by Oxford University Press.

  1. Phylo: a citizen science approach for improving multiple sequence alignment.

    Directory of Open Access Journals (Sweden)

    Alexander Kawrykow

    Full Text Available BACKGROUND: Comparative genomics, or the study of the relationships of genome structure and function across different species, offers a powerful tool for studying evolution, annotating genomes, and understanding the causes of various genetic disorders. However, aligning multiple sequences of DNA, an essential intermediate step for most types of analyses, is a difficult computational task. In parallel, citizen science, an approach that takes advantage of the fact that the human brain is exquisitely tuned to solving specific types of problems, is becoming increasingly popular. There, instances of hard computational problems are dispatched to a crowd of non-expert human game players and solutions are sent back to a central server. METHODOLOGY/PRINCIPAL FINDINGS: We introduce Phylo, a human-based computing framework applying "crowd sourcing" techniques to solve the Multiple Sequence Alignment (MSA problem. The key idea of Phylo is to convert the MSA problem into a casual game that can be played by ordinary web users with a minimal prior knowledge of the biological context. We applied this strategy to improve the alignment of the promoters of disease-related genes from up to 44 vertebrate species. Since the launch in November 2010, we received more than 350,000 solutions submitted from more than 12,000 registered users. Our results show that solutions submitted contributed to improving the accuracy of up to 70% of the alignment blocks considered. CONCLUSIONS/SIGNIFICANCE: We demonstrate that, combined with classical algorithms, crowd computing techniques can be successfully used to help improving the accuracy of MSA. More importantly, we show that an NP-hard computational problem can be embedded in casual game that can be easily played by people without significant scientific training. This suggests that citizen science approaches can be used to exploit the billions of "human-brain peta-flops" of computation that are spent every day playing games

  2. Fast spine echo and fast fluid attenuated inversion recovery sequences in multiple sclerosis

    International Nuclear Information System (INIS)

    Paolillo, Andrea; Giugni, Elisabetta; Bozzao, Alessandro; Bastianello, Stefano

    1997-01-01

    Fast spin echo (FSE) and fast fluid attenuated inversion recovery (fast-FLAIR) sequences, were compared with conventional spin echo (CSE) in quantitating multiple sclerosis (MS) lesion burden. For each sequence, the total number and volume of MS lesions were calculated in 38 remitting multiple sclerosis patients using a semiautomated lesion detection program. Conventional spin echo, fast spin echo, and fast fluid attenuated inversion recovery image were reported on randomly and at different times by two expert observers. Interobserver differences, the time needed to quantitative multiple sclerosis lesions and lesion signal intensity (contrast-to-noise ratio and overall contrast) were considered. The lesions were classified by site into infratentorial, white matter and cortical/subcortical. A total of 2970 lesions with a volume of 961.7 cm 3 was calculated on conventional spin echo images. Fast spin echo images depicted fewer (16.6%; p < .005) and smaller (24.9%; p < .0001) lesions and the differences were statistically significant. Despite an overall nonsignificant reduction for fast-FLAIR images (-5% and 4.8% for lesion number and volume, respectively), significantly lower values (lesion number: p < 0.1; volume: p < .04)were observed for infratentorial lesions, while significantly higher values were seen for cortical/subcortical lesions (lesion number: p < .01; volume: p < .02). A higher lesion/white matter contrast (p < .002), a significant time saving for lesion burden quantitation (p < .05) and very low interobserver variability were found in favor of fast-FLAIR. Our data suggest that, despite the limitations regarding infratentorial lesions, fast-FLAIR sequences are indicated in R studies because of their good identification of cortical/subcortical lesions, almost complete interobserver agreement, higher contrast-to-noise ratio and limited time needed for semiautomated quantitation

  3. Safety Assessment of Advanced Imaging Sequences I: Measurements

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Rasmussen, Morten Fischer; Pihl, Michael Johannes

    2016-01-01

    intensity measurement program. The approach can measure and store data for a full imaging sequence in 3.8 to 8.2 s per spatial position. Based on Ispta, MI, and probe surface temperature, the method gives the ability to determine whether a sequence is within US FDA limits, or alternatively indicate how......A method for rapid measurement of intensities (Ispta), mechanical index (MI), and probe surface temperature for any ultrasound scanning sequence is presented. It uses the scanner’s sampling capability to give an accurate measurement of the whole imaging sequence for all emissions to yield the true...... measurement system (Onda Corporation, Sunnyvale, CA, USA). Four different sequences have been measured: a fixed focus emission, a duplex sequence containing B-mode and flow emissions, a vector flow sequence with B-mode and flow emissions in 17 directions, and finally a synthetic aperture (SA) duplex flow...

  4. Next-generation sequencing of multiple individuals per barcoded library by deconvolution of sequenced amplicons using endonuclease fragment analysis

    DEFF Research Database (Denmark)

    Andersen, Jeppe D; Pereira, Vania; Pietroni, Carlotta

    2014-01-01

    The simultaneous sequencing of samples from multiple individuals increases the efficiency of next-generation sequencing (NGS) while also reducing costs. Here we describe a novel and simple approach for sequencing DNA from multiple individuals per barcode. Our strategy relies on the endonuclease...... digestion of PCR amplicons prior to library preparation, creating a specific fragment pattern for each individual that can be resolved after sequencing. By using both barcodes and restriction fragment patterns, we demonstrate the ability to sequence the human melanocortin 1 receptor (MC1R) genes from 72...... individuals using only 24 barcoded libraries....

  5. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kesselring, J.; Ormerod, I.E.C.; Miller, D.H.; Du Boulay, G.H.; McDonald, W.I.

    1989-01-01

    In 1983 the Multiple Sclerosis Society of Great Britain and Northern Ireland set up the Multiple Sclerosis NMR Research Group at the Institute of Neurology and the National Hospital, Queen Square. The first aim of the Group was to define the role of MRI in the diagnosis and differential diagnosis of multiple sclerosis, and this Atlas represents a summary of that work. Our strategy was to determine the pattern of MRI abnormalities in clinically definite MS and to compare it with those of isolated clinical syndromes of the kind seen in MS (e.g. optic neuritis) and of other disorders with which MS can be confused clinically or radiologically. We have also been involved in a major program of experimental work designed to elucidate the origin of the abnormal signals in MRI. To describe this in full detail would go beyond the scope of the Atlas, but we have incorporated such results as far as they illuminate our clinical problems. The imager used was a 0.5 Tesla Picker superconducting system. Technical advances have been rapid since we began. Nevertheless, the quality of the images obtained at our relatively low field has enabled us to establish the patterns of abnormality in the brain in MS and the diseases which must be distinguished from it. (orig./MG)

  6. Optimal pulse-sequence parameters for MR imaging of the immature brain

    International Nuclear Information System (INIS)

    Nowell, M.A.; Hackney, D.B.; Zimmerman, R.A.; Bilaniuk, L.T.; Grossman, R.I.; Goldberg, H.I.

    1986-01-01

    Appropriate spin-echo pulse sequence parameters generate MR images with very high gray matter/white matter contrast in neonates and young infants. Low-contrast images appear to result from utilization of ''adult-type'' parameters to investigate tissues that have relaxation characteristics quite different than those of adult brain. In these young patients long spin-echo sequences with repetition times of 3,000-3,500 msec and multiple echoes with the longest echo time set at 120-160 msec are employed to yield high-contrast ''T2-weighted'' images

  7. The use of coded PCR primers enables high-throughput sequencing of multiple homolog amplification products by 454 parallel sequencing.

    Directory of Open Access Journals (Sweden)

    Jonas Binladen

    2007-02-01

    Full Text Available The invention of the Genome Sequence 20 DNA Sequencing System (454 parallel sequencing platform has enabled the rapid and high-volume production of sequence data. Until now, however, individual emulsion PCR (emPCR reactions and subsequent sequencing runs have been unable to combine template DNA from multiple individuals, as homologous sequences cannot be subsequently assigned to their original sources.We use conventional PCR with 5'-nucleotide tagged primers to generate homologous DNA amplification products from multiple specimens, followed by sequencing through the high-throughput Genome Sequence 20 DNA Sequencing System (GS20, Roche/454 Life Sciences. Each DNA sequence is subsequently traced back to its individual source through 5'tag-analysis.We demonstrate that this new approach enables the assignment of virtually all the generated DNA sequences to the correct source once sequencing anomalies are accounted for (miss-assignment rate<0.4%. Therefore, the method enables accurate sequencing and assignment of homologous DNA sequences from multiple sources in single high-throughput GS20 run. We observe a bias in the distribution of the differently tagged primers that is dependent on the 5' nucleotide of the tag. In particular, primers 5' labelled with a cytosine are heavily overrepresented among the final sequences, while those 5' labelled with a thymine are strongly underrepresented. A weaker bias also exists with regards to the distribution of the sequences as sorted by the second nucleotide of the dinucleotide tags. As the results are based on a single GS20 run, the general applicability of the approach requires confirmation. However, our experiments demonstrate that 5'primer tagging is a useful method in which the sequencing power of the GS20 can be applied to PCR-based assays of multiple homologous PCR products. The new approach will be of value to a broad range of research areas, such as those of comparative genomics, complete mitochondrial

  8. Remote Sensing Image Registration Using Multiple Image Features

    Directory of Open Access Journals (Sweden)

    Kun Yang

    2017-06-01

    Full Text Available Remote sensing image registration plays an important role in military and civilian fields, such as natural disaster damage assessment, military damage assessment and ground targets identification, etc. However, due to the ground relief variations and imaging viewpoint changes, non-rigid geometric distortion occurs between remote sensing images with different viewpoint, which further increases the difficulty of remote sensing image registration. To address the problem, we propose a multi-viewpoint remote sensing image registration method which contains the following contributions. (i A multiple features based finite mixture model is constructed for dealing with different types of image features. (ii Three features are combined and substituted into the mixture model to form a feature complementation, i.e., the Euclidean distance and shape context are used to measure the similarity of geometric structure, and the SIFT (scale-invariant feature transform distance which is endowed with the intensity information is used to measure the scale space extrema. (iii To prevent the ill-posed problem, a geometric constraint term is introduced into the L2E-based energy function for better behaving the non-rigid transformation. We evaluated the performances of the proposed method by three series of remote sensing images obtained from the unmanned aerial vehicle (UAV and Google Earth, and compared with five state-of-the-art methods where our method shows the best alignments in most cases.

  9. Spatio-temporal alignment of pedobarographic image sequences.

    Science.gov (United States)

    Oliveira, Francisco P M; Sousa, Andreia; Santos, Rubim; Tavares, João Manuel R S

    2011-07-01

    This article presents a methodology to align plantar pressure image sequences simultaneously in time and space. The spatial position and orientation of a foot in a sequence are changed to match the foot represented in a second sequence. Simultaneously with the spatial alignment, the temporal scale of the first sequence is transformed with the aim of synchronizing the two input footsteps. Consequently, the spatial correspondence of the foot regions along the sequences as well as the temporal synchronizing is automatically attained, making the study easier and more straightforward. In terms of spatial alignment, the methodology can use one of four possible geometric transformation models: rigid, similarity, affine, or projective. In the temporal alignment, a polynomial transformation up to the 4th degree can be adopted in order to model linear and curved time behaviors. Suitable geometric and temporal transformations are found by minimizing the mean squared error (MSE) between the input sequences. The methodology was tested on a set of real image sequences acquired from a common pedobarographic device. When used in experimental cases generated by applying geometric and temporal control transformations, the methodology revealed high accuracy. In addition, the intra-subject alignment tests from real plantar pressure image sequences showed that the curved temporal models produced better MSE results (P alignment of pedobarographic image data, since previous methods can only be applied on static images.

  10. Benefits and limitations of imaging multiples: Mirror migration

    KAUST Repository

    Hanafy, Sherif M.; Huang, Yunsong; Schuster, Gerard T.

    2015-01-01

    The benefits and limitations of imaging multiples are reviewed for mirror migration. Synthetic and field data examples are used to characterize the effectiveness of migrating multiples relative to primary imaging.

  11. Benefits and limitations of imaging multiples: Mirror migration

    KAUST Repository

    Hanafy, Sherif M.

    2015-07-01

    The benefits and limitations of imaging multiples are reviewed for mirror migration. Synthetic and field data examples are used to characterize the effectiveness of migrating multiples relative to primary imaging.

  12. Motion Detection in Ultrasound Image-Sequences Using Tensor Voting

    Science.gov (United States)

    Inba, Masafumi; Yanagida, Hirotaka; Tamura, Yasutaka

    2008-05-01

    Motion detection in ultrasound image sequences using tensor voting is described. We have been developing an ultrasound imaging system adopting a combination of coded excitation and synthetic aperture focusing techniques. In our method, frame rate of the system at distance of 150 mm reaches 5000 frame/s. Sparse array and short duration coded ultrasound signals are used for high-speed data acquisition. However, many artifacts appear in the reconstructed image sequences because of the incompleteness of the transmitted code. To reduce the artifacts, we have examined the application of tensor voting to the imaging method which adopts both coded excitation and synthetic aperture techniques. In this study, the basis of applying tensor voting and the motion detection method to ultrasound images is derived. It was confirmed that velocity detection and feature enhancement are possible using tensor voting in the time and space of simulated ultrasound three-dimensional image sequences.

  13. Fat suppression in MR imaging with binomial pulse sequences

    International Nuclear Information System (INIS)

    Baudovin, C.J.; Bryant, D.J.; Bydder, G.M.; Young, I.R.

    1989-01-01

    This paper reports on a study to develop pulse sequences allowing suppression of fat signal on MR images without eliminating signal from other tissues with short T1. They have developed such a technique involving selective excitation of protons in water, based on a binomial pulse sequence. Imaging is performed at 0.15 T. Careful shimming is performed to maximize separation of fat and water peaks. A spin-echo 1,500/80 sequence is used, employing 90 degrees pulse with transit frequency optimized for water with null excitation of 20 H offset, followed by a section-selective 180 degrees pulse. With use of the binomial sequence for imagining, reduction in fat signal is seen on images of the pelvis and legs of volunteers. Patient studies show dramatic improvement in visualization of prostatic carcinoma compared with standard sequences

  14. Image encryption using random sequence generated from generalized information domain

    International Nuclear Information System (INIS)

    Zhang Xia-Yan; Wu Jie-Hua; Zhang Guo-Ji; Li Xuan; Ren Ya-Zhou

    2016-01-01

    A novel image encryption method based on the random sequence generated from the generalized information domain and permutation–diffusion architecture is proposed. The random sequence is generated by reconstruction from the generalized information file and discrete trajectory extraction from the data stream. The trajectory address sequence is used to generate a P-box to shuffle the plain image while random sequences are treated as keystreams. A new factor called drift factor is employed to accelerate and enhance the performance of the random sequence generator. An initial value is introduced to make the encryption method an approximately one-time pad. Experimental results show that the random sequences pass the NIST statistical test with a high ratio and extensive analysis demonstrates that the new encryption scheme has superior security. (paper)

  15. Imaging outcomes for trials of remyelination in multiple sclerosis.

    Science.gov (United States)

    Mallik, Shahrukh; Samson, Rebecca S; Wheeler-Kingshott, Claudia A M; Miller, David H

    2014-12-01

    Trials of potential neuroreparative agents are becoming more important in the spectrum of multiple sclerosis research. Appropriate imaging outcomes are required that are feasible from a time and practicality point of view, as well as being sensitive and specific to myelin, while also being reproducible and clinically meaningful. Conventional MRI sequences have limited specificity for myelination. We evaluate the imaging modalities which are potentially more specific to myelin content in vivo, such as magnetisation transfer ratio (MTR), restricted proton fraction f (from quantitative magnetisation transfer measurements), myelin water fraction and diffusion tensor imaging (DTI) metrics, in addition to positron emission tomography (PET) imaging. Although most imaging applications to date have focused on the brain, we also consider measures with the potential to detect remyelination in the spinal cord and in the optic nerve. At present, MTR and DTI measures probably offer the most realistic and feasible outcome measures for such trials, especially in the brain. However, no one measure currently demonstrates sufficiently high sensitivity or specificity to myelin, or correlation with clinical features, and it should be useful to employ more than one outcome to maximise understanding and interpretation of findings with these sequences. PET may be less feasible for current and near-future trials, but is a promising technique because of its specificity. In the optic nerve, visual evoked potentials can indicate demyelination and should be correlated with an imaging outcome (such as optic nerve MTR), as well as clinical measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Image ranking in video sequences using pairwise image comparisons and temporal smoothing

    CSIR Research Space (South Africa)

    Burke, Michael

    2016-12-01

    Full Text Available The ability to predict the importance of an image is highly desirable in computer vision. This work introduces an image ranking scheme suitable for use in video or image sequences. Pairwise image comparisons are used to determine image ‘interest...

  17. Image Alignment for Multiple Camera High Dynamic Range Microscopy

    OpenAIRE

    Eastwood, Brian S.; Childs, Elisabeth C.

    2012-01-01

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability fo...

  18. Multiple image x-radiography for functional lung imaging

    Science.gov (United States)

    Aulakh, G. K.; Mann, A.; Belev, G.; Wiebe, S.; Kuebler, W. M.; Singh, B.; Chapman, D.

    2018-01-01

    Detection and visualization of lung tissue structures is impaired by predominance of air. However, by using synchrotron x-rays, refraction of x-rays at the interface of tissue and air can be utilized to generate contrast which may in turn enable quantification of lung optical properties. We utilized multiple image radiography, a variant of diffraction enhanced imaging, at the Canadian light source to quantify changes in unique x-ray optical properties of lungs, namely attenuation, refraction and ultra small-angle scatter (USAXS or width) contrast ratios as a function of lung orientation in free-breathing or respiratory-gated mice before and after intra-nasal bacterial endotoxin (lipopolysaccharide) instillation. The lung ultra small-angle scatter and attenuation contrast ratios were significantly higher 9 h post lipopolysaccharide instillation compared to saline treatment whereas the refraction contrast decreased in magnitude. In ventilated mice, end-expiratory pressures result in an increase in ultra small-angle scatter contrast ratio when compared to end-inspiratory pressures. There were no detectable changes in lung attenuation or refraction contrast ratio with change in lung pressure alone. In effect, multiple image radiography can be applied towards following optical properties of lung air-tissue barrier over time during pathologies such as acute lung injury.

  19. New diffusion imaging method with a single acquisition sequence

    International Nuclear Information System (INIS)

    Melki, Ph.S.; Bittoun, J.; Lefevre, J.E.

    1987-01-01

    The apparent diffusion coefficient (ADC) is related to the molecular diffusion coefficient and to physiologic information: microcirculation in the capillary network, incoherent slow flow, and restricted diffusion. The authors present a new MR imaging sequence that yields computed ADC images in only one acquisition of 9-minutes with a 1.5-T imager (GE Signa). Compared to the previous method, this sequence is at least two times faster and thus can be used as a routine examination to supplement T1-, T2-, and density-weighted images. The method was assessed by measurement of the molecular diffusion in liquids, and the first clinical images obtained in neurologic diseases demonstrate its efficiency for clinical investigation. The possibility of separately imaging diffusion and perfusion is supported by an algorithm

  20. Reconstructed Image Spatial Resolution of Multiple Coincidences Compton Imager

    Science.gov (United States)

    Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna

    2010-02-01

    We study the multiple coincidences Compton imager (MCCI) which is based on a simultaneous acquisition of several photons emitted in cascade from a single nuclear decay. Theoretically, this technique should provide a major improvement in localization of a single radioactive source as compared to a standard Compton camera. In this work, we investigated the performance and limitations of MCCI using Monte Carlo computer simulations. Spatial resolutions of the reconstructed point source have been studied as a function of the MCCI parameters, including geometrical dimensions and detector characteristics such as materials, energy and spatial resolutions.

  1. Retrieval of Sentence Sequences for an Image Stream via Coherence Recurrent Convolutional Networks.

    Science.gov (United States)

    Park, Cesc Chunseong; Kim, Youngjin; Kim, Gunhee

    2018-04-01

    We propose an approach for retrieving a sequence of natural sentences for an image stream. Since general users often take a series of pictures on their experiences, much online visual information exists in the form of image streams, for which it would better take into consideration of the whole image stream to produce natural language descriptions. While almost all previous studies have dealt with the relation between a single image and a single natural sentence, our work extends both input and output dimension to a sequence of images and a sequence of sentences. For retrieving a coherent flow of multiple sentences for a photo stream, we propose a multimodal neural architecture called coherence recurrent convolutional network (CRCN), which consists of convolutional neural networks, bidirectional long short-term memory (LSTM) networks, and an entity-based local coherence model. Our approach directly learns from vast user-generated resource of blog posts as text-image parallel training data. We collect more than 22 K unique blog posts with 170 K associated images for the travel topics of NYC, Disneyland , Australia, and Hawaii. We demonstrate that our approach outperforms other state-of-the-art image captioning methods for text sequence generation, using both quantitative measures and user studies via Amazon Mechanical Turk.

  2. BLAST and FASTA similarity searching for multiple sequence alignment.

    Science.gov (United States)

    Pearson, William R

    2014-01-01

    BLAST, FASTA, and other similarity searching programs seek to identify homologous proteins and DNA sequences based on excess sequence similarity. If two sequences share much more similarity than expected by chance, the simplest explanation for the excess similarity is common ancestry-homology. The most effective similarity searches compare protein sequences, rather than DNA sequences, for sequences that encode proteins, and use expectation values, rather than percent identity, to infer homology. The BLAST and FASTA packages of sequence comparison programs provide programs for comparing protein and DNA sequences to protein databases (the most sensitive searches). Protein and translated-DNA comparisons to protein databases routinely allow evolutionary look back times from 1 to 2 billion years; DNA:DNA searches are 5-10-fold less sensitive. BLAST and FASTA can be run on popular web sites, but can also be downloaded and installed on local computers. With local installation, target databases can be customized for the sequence data being characterized. With today's very large protein databases, search sensitivity can also be improved by searching smaller comprehensive databases, for example, a complete protein set from an evolutionarily neighboring model organism. By default, BLAST and FASTA use scoring strategies target for distant evolutionary relationships; for comparisons involving short domains or queries, or searches that seek relatively close homologs (e.g. mouse-human), shallower scoring matrices will be more effective. Both BLAST and FASTA provide very accurate statistical estimates, which can be used to reliably identify protein sequences that diverged more than 2 billion years ago.

  3. Images crossing borders: image and workflow sharing on multiple levels.

    Science.gov (United States)

    Ross, Peeter; Pohjonen, Hanna

    2011-04-01

    Digitalisation of medical data makes it possible to share images and workflows between related parties. In addition to linear data flow where healthcare professionals or patients are the information carriers, a new type of matrix of many-to-many connections is emerging. Implementation of shared workflow brings challenges of interoperability and legal clarity. Sharing images or workflows can be implemented on different levels with different challenges: inside the organisation, between organisations, across country borders, or between healthcare institutions and citizens. Interoperability issues vary according to the level of sharing and are either technical or semantic, including language. Legal uncertainty increases when crossing national borders. Teleradiology is regulated by multiple European Union (EU) directives and legal documents, which makes interpretation of the legal system complex. To achieve wider use of eHealth and teleradiology several strategic documents were published recently by the EU. Despite EU activities, responsibility for organising, providing and funding healthcare systems remains with the Member States. Therefore, the implementation of new solutions requires strong co-operation between radiologists, societies of radiology, healthcare administrators, politicians and relevant EU authorities. The aim of this article is to describe different dimensions of image and workflow sharing and to analyse legal acts concerning teleradiology in the EU.

  4. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) of the brain was performed in a total of 45 patients with multiple sclerosis (MS), comprising 27 with brain symptoms and 18 without it. The results were compared with X-ray computed tomography (CT). Some of the 45 MS patients were also examined by neurophysiological studies for comparison. MRI showed demyelinating plaques of the brain in a total of 31 patients (69%) - 20 symptomatic and 11 asymptomatic patients. For symptomatic patients, MRI was capable of detecting brain lesions in 6 (86%) of 7 acute stage patients and 14 (70%) of 20 non-acute stage patients. It was also capable of detecting brain lesions in 21 (70%) of 30 clinically definite MR patients and 10 (67%) of 15 clinically probable MS patients. Concurrently available X-ray CT revealed brain lesions in 9 symptomatic patients (33%) and one asymptomatic patient (6%). Visual evoked potentials examined in 31 patients showed abnormality in one (11%) of 9 patients without symptoms of optic neuritis and all (100%) of the other 22 patients with symptoms. In 19 evaluable patients, auditory brainstem responses were abnormal in one (11%) of 9 patients without brainstem symptoms and 3 (30%) of 10 patients with symptoms. MRI of the brain was far superior to X-ray CT, visual evoked potentials and auditory brainstem responses in detecting clinically unsuspected lesions. We proposed new diagnostic criteria including MRI findings of the brain in the Japanese MS diagnostic criteria. MRI of the spinal cord was performed in 12 MS patients with spinal cord symptoms by sagittal and coronal images. It demonstrated demyelinating lesions within the cervical and superior thoracic cord in 8 MS acute stage patients. Spinal cord lesions were longitudinally continuous as long as many spinal segments, with swelling in 6 patients and atrophy in 2 patients. MRI of spinal cord was useful in deciding superior and inferior limits of cord lesions and in visualizing cord swelling or atrophy. (Namekawa, K)

  5. Extracting flat-field images from scene-based image sequences using phase correlation

    Energy Technology Data Exchange (ETDEWEB)

    Caron, James N., E-mail: Caron@RSImd.com [Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706 (United States); Montes, Marcos J. [Naval Research Laboratory, Code 7231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Obermark, Jerome L. [Naval Research Laboratory, Code 8231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States)

    2016-06-15

    Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

  6. MISTICA: Minimum Spanning Tree-Based Coarse Image Alignment for Microscopy Image Sequences.

    Science.gov (United States)

    Ray, Nilanjan; McArdle, Sara; Ley, Klaus; Acton, Scott T

    2016-11-01

    Registration of an in vivo microscopy image sequence is necessary in many significant studies, including studies of atherosclerosis in large arteries and the heart. Significant cardiac and respiratory motion of the living subject, occasional spells of focal plane changes, drift in the field of view, and long image sequences are the principal roadblocks. The first step in such a registration process is the removal of translational and rotational motion. Next, a deformable registration can be performed. The focus of our study here is to remove the translation and/or rigid body motion that we refer to here as coarse alignment. The existing techniques for coarse alignment are unable to accommodate long sequences often consisting of periods of poor quality images (as quantified by a suitable perceptual measure). Many existing methods require the user to select an anchor image to which other images are registered. We propose a novel method for coarse image sequence alignment based on minimum weighted spanning trees (MISTICA) that overcomes these difficulties. The principal idea behind MISTICA is to reorder the images in shorter sequences, to demote nonconforming or poor quality images in the registration process, and to mitigate the error propagation. The anchor image is selected automatically making MISTICA completely automated. MISTICA is computationally efficient. It has a single tuning parameter that determines graph width, which can also be eliminated by the way of additional computation. MISTICA outperforms existing alignment methods when applied to microscopy image sequences of mouse arteries.

  7. Magnetic resonance imaging in optic nerve lesions with multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo; Kakisu, Yonetsugu; Adachi, Emiko

    1990-01-01

    Magnetic resonance imaging (MRI) of the optic nerve was performed in 10 patients with multiple sclerosis (MS) using short inversion time inversion recovery (STIR) pulse sequences, and the results were compared with the visual evoked potentials (VEP). The 10 patients had optic neuritis in the chronic or remitting phase together with additional symptoms or signs allowing a diagnosis of clinically definite or probable MS. Sixteen optic nerves were clinically affected and 4 were unaffected. MRI was performed using a 0.5 tesla supeconducting unit, and multiple continuous 5 mm coronal and axial STIR images were obtained. A lesion was judged to be present if a focal or diffuse area of increased signal intensity was detectd in the optic nerve. In VEP, a delay in peak latency or no P 100 component was judged to be abnormal. With regard to the clinically affected optic nerves, MRI revealed a region of increased signal intensity in 14/16 (88%) and the VEP was abnormal in 16/16 (100%). In the clinically unaffected optic nerves, MRI revealed an increased signal intensity in 2/4 (50%). One of these nerves had an abnormal VEP and the other had a VEP latency at the upper limit of normal. The VEP was abnormal in 1/4 (25%). In the clinically affected optic nerves, the degree of loss of visual acuity was not associated with the longitudinal extent of the lesions shown by MRI. The mean length was 17.5 mm in optic nerves with a slight disturbance of visual acuity and 15.0 mm in nerves with severe visual loss. MRI using STIR pulse sequences was found to be almost as sensitive as VEP in detecting both clinically affected and unaffected optic nerve lesions in patients with MS, and was useful in visualizing the location or size of the lesions. (author)

  8. Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Roque, Andreia; Ramalho, Miguel; AlObaidy, Mamdoh; Heredia, Vasco; Burke, Lauren M.; De Campos, Rafael O.P.; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2014-10-15

    Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. To compare the image quality of three different post-contrast T1-weighted imaging techniques - standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE) - acquired in pediatric patients younger than 5 years of age. Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential. (orig.)

  9. Geometrical primitives reconstruction from image sequence in an interactive context

    International Nuclear Information System (INIS)

    Monchal, L.; Aubry, P.

    1995-01-01

    We propose a method to recover 3D geometrical shape from image sequence, in a context of man machine co-operation. The human operator has to point out the edges of an object in the first image and choose a corresponding geometrical model. The algorithm tracks each relevant 2D segments describing surface discontinuities or limbs, in the images. Then, knowing motion of the camera between images, the positioning and the size of the virtual object are deduced by minimising a function. The function describes how well the virtual objects is linked to the extracted segments of the sequence, its geometrical model and pieces of information given by the operator. (author). 13 refs., 7 figs., 8 tabs

  10. Far-field super-resolution imaging of resonant multiples

    KAUST Repository

    Guo, Bowen

    2016-05-20

    We demonstrate for the first time that seismic resonant multiples, usually considered as noise, can be used for super-resolution imaging in the far-field region of sources and receivers. Tests with both synthetic data and field data show that resonant multiples can image reflector boundaries with resolutions more than twice the classical resolution limit. Resolution increases with the order of the resonant multiples. This procedure has important applications in earthquake and exploration seismology, radar, sonar, LIDAR (light detection and ranging), and ultrasound imaging, where the multiples can be used to make high-resolution images.

  11. MR imaging pulse sequence rationale: SD-, T1-, and T2-weighted images

    International Nuclear Information System (INIS)

    Sax, S.; Weathers, S.W.; Schneiders, N.J.; Horowitz, B.L.; Mawad, M.E.; Sandlin, M.E.; Blackwell, R.; Bryan, R.N.

    1986-01-01

    Over 500 patients have been examined with a pulse sequence designed to provide spin-density (SD)-weighted images (TR=3 sec, TE=35 msec), T1-weighted images (TR=0.3 sec, TE=35msec), and T2-weighted images (TR=3 sec, TE=105 msec) from which calculated ''synthesized'' images and SD, T1, and T2 calculated images could be obtained. Each image contributes unique information. SD-weighted images optimally display anatomy and often best highlight pathology. T1-weighted images are critical in assessing cerebral hemorrhages. T2-weighted images best display most lesions, but yield incomplete information in 35% of cases. All three types of ''weighted'' images are necessary to optimally display anatomy and fully characterize a lesion. Computerized calculations and simulations suggest that no other combination of pulse sequences yields equal information for a given examination time

  12. Diffusion Weighted Imaging in Acute Attacks of Multiple Sclerosis

    International Nuclear Information System (INIS)

    Davoudi, Yasmin; Foroughipour, Mohsen; Torabi, Reza; Layegh, Parvaneh; Matin, Nassim; Shoeibi, Ali

    2016-01-01

    Multiple sclerosis (MS) is one of the most common autoimmune disorders of the central nervous system. In spite of various imaging modalities, the definitive diagnosis of MS remains challenging. This study was designed to evaluate the usefulness of diffusion weighted imaging (DWI) in the diagnosis of acute MS attack and to compare its results with contrast enhanced MRI (CE-MRI). In this cross sectional study, seventy patients with definite diagnosis of relapsing-remitting MS were included. CE-MRI using 0.1 mmol/kg gadolinium as well as DWI sequences were performed for all patients. The percentage of patients with positive DWI was compared with the results of CE-MRI and the consistency between the two imaging modalities was evaluated. Moreover, the relationship between the time of onset of patient’s symptoms and test results for both methods were investigated. CE-MRI yielded positive results for 61 (87%) patients and DWI yielded positive for 53 (76%) patients. In fifty patients (71.42%), both tests were positive and in six cases (8.57%), both were negative. The test results of three patients turned out to be positive in DWI, while they tested negative in CE-MRI. There was no significant relationship between the results of CE-MRI as well as DWI and the time of imaging from the onset of symptoms. These data indicate that while CE-MRI will depict more positive results, there are cases in which DWI will show a positive result while CE-MRI is negative. We suggest that the combination of these two imaging modalities might yield more positive results in diagnosing acute MS attack giving rise to a more accurate diagnosis

  13. Simulation and Efficient Measurements of Intensities for Complex Imaging Sequences

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Rasmussen, Morten Fischer; Stuart, Matthias Bo

    2014-01-01

    on the sequence to simulate both intensity and mechanical index (MI) according to FDA rules. A 3 MHz BK Medical 8820e convex array transducer is used with the SARUS scanner. An Onda HFL-0400 hydrophone and the Onda AIMS III system measures the pressure field for three imaging schemes: a fixed focus, single...

  14. Light chain deposition disease in multiple myeloma: MR imaging features correlated with histopathological findings

    International Nuclear Information System (INIS)

    Baur, A.; Staebler, A.; Reiser, M.; Lamerz, R.; Bartl, R.

    1998-01-01

    The clinical, histopathological, and imaging findings on MRI of a 56-year-old woman with light chain deposition disease occurring in multiple myeloma are presented. Light chain deposition disease is a variant of multiple myeloma with distinct clinical and histological characteristics. MRI of this patient also revealed an infiltration pattern in the bone marrow distinct from that of typical multiple myeloma. Multiple small foci of low signal intensity were present on T1- and T2-weighted spin echo and STIR images, corresponding to conglomerates of light chains in bone marrow biopsy. Contrast-enhanced T1-weighted spin echo images show diffuse enhancement of 51% over all vertebral bodies, with a minor enhancement of the focal conglomerates of light chains. Light chain deposition disease in multiple myeloma should be added to the list of those few entities with normal radiographs and discrete low-signal marrow lesions on T1- and T2-weighted spin echo pulse sequences. (orig.)

  15. Improved nonparametric inference for multiple correlated periodic sequences

    KAUST Repository

    Sun, Ying; Hart, Jeffrey D.; Genton, Marc G.

    2013-01-01

    cross-validation method to the temperature data obtained from multiple ice cores, investigating the periodicity of the El Niño effect. Our methodology is also illustrated by estimating patients' cardiac cycle from different physiological signals

  16. Studying a free fall experiment using short sequences of images

    International Nuclear Information System (INIS)

    Vera, Francisco; Romanque, Cristian

    2008-01-01

    We discuss a new alternative for obtaining position and time coordinates from a video of a free fall experiment. In our approach, after converting the video to a short sequence of images, the images are analyzed using a web page application developed by the author. The main advantage of the setup explained in this work, is that it is simple to use, no software license fees are necessary, and can be scaled-up to be used by a big number of students in introductory physics courses. The steps involved in the full analysis of a falling object are: we grab a short digital video of the experiment and convert it to a sequence of images, then, using a web page that includes all the necessary javascript, the student can easily click on the object of interest to obtain the (x,y,t) coordinates, finally, the student analyze motion using a spreadsheet.

  17. Long multiplication by instruction sequences with backward jump instructions

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2013-01-01

    For each function on bit strings, its restriction to bit strings of any given length can be computed by a finite instruction sequence that contains only instructions to set and get the content of Boolean registers, forward jump instructions, and a termination instruction. Backward jump instructions

  18. Extended -Regular Sequence for Automated Analysis of Microarray Images

    Directory of Open Access Journals (Sweden)

    Jin Hee-Jeong

    2006-01-01

    Full Text Available Microarray study enables us to obtain hundreds of thousands of expressions of genes or genotypes at once, and it is an indispensable technology for genome research. The first step is the analysis of scanned microarray images. This is the most important procedure for obtaining biologically reliable data. Currently most microarray image processing systems require burdensome manual block/spot indexing work. Since the amount of experimental data is increasing very quickly, automated microarray image analysis software becomes important. In this paper, we propose two automated methods for analyzing microarray images. First, we propose the extended -regular sequence to index blocks and spots, which enables a novel automatic gridding procedure. Second, we provide a methodology, hierarchical metagrid alignment, to allow reliable and efficient batch processing for a set of microarray images. Experimental results show that the proposed methods are more reliable and convenient than the commercial tools.

  19. THE MULTIPLE PRE-MAIN-SEQUENCE SYSTEM HBC 515 IN L1622

    International Nuclear Information System (INIS)

    Reipurth, Bo; Aspin, Colin; Herbig, George

    2010-01-01

    The bright pre-main-sequence star HBC 515 (HD 288313) located in the L1622 cometary cloud in Orion has been studied extensively with optical/infrared imaging and ultraviolet/optical/infrared spectroscopy. The spectra indicate that HBC 515 is a weakline T Tauri star (TTS) of spectral type K2V. Adaptive optics imaging in the K band reveals that HBC 515 is a binary with two equally bright components separated by 0.''5. A very faint third component is found 5'' to the northwest. Spitzer IRAC and MIPS observations show that at mid-infrared wavelengths this third source dominates the system, suggesting that it is a protostar still embedded in the nascent cloud of HBC 515. The close association of a weakline TTS with a newborn protostar in a multiple system is noteworthy. Two nearby TTSs are likely associated with the HBC 515 multiple system, and the dynamical evolution of the complex that would lead to such a configuration is considered.

  20. Viewing multiple sequence alignments with the JavaScript Sequence Alignment Viewer (JSAV).

    Science.gov (United States)

    Martin, Andrew C R

    2014-01-01

    The JavaScript Sequence Alignment Viewer (JSAV) is designed as a simple-to-use JavaScript component for displaying sequence alignments on web pages. The display of sequences is highly configurable with options to allow alternative coloring schemes, sorting of sequences and 'dotifying' repeated amino acids. An option is also available to submit selected sequences to another web site, or to other JavaScript code. JSAV is implemented purely in JavaScript making use of the JQuery and JQuery-UI libraries. It does not use any HTML5-specific options to help with browser compatibility. The code is documented using JSDOC and is available from http://www.bioinf.org.uk/software/jsav/.

  1. Magnetic resonance imaging of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Yagishita, Toshiyuki; Fukutake, Toshio; Hirayama, Keizo; Fukuda, Nobuo.

    1987-01-01

    Magnetic resonance imaging (MRI) was used in three patients with multiple sclerosis (MS) to demonstrate the longitudinal distribution of demyelinating plaques in the spinal cord and to measure their T1 relaxation time values in these disease processes. Neurological examination allowed the detection of the superior limit of the spinal cord lesions in the three patients, but did not permit detection of the inferior limit in two of the patients. With MRI, however, it was possible to demonstrate the longitudinal distribution of demyelinating plaques in all three patients from coronal or sagittal images using spin echo and inversion recovery pulse sequences. In two patients treated with prednisolone, serial T1 relaxation time values of MS spinal cord lesions were measured from T1 calculated images. In one patient with transverse myelopathy, the T1 relaxation time values of MS spinal cord lesions were significantly increased at a stage of acute exacerbation. This is apparently in contrast with the values at the stage of remission. In the patient with localized cervical myelopathy, the increase in T1 relaxation time values of MS spinal cord lesions at the acute stage was small and significantly different from the values at the remission stage. Several recent reports have indicated that MRI is extremely sensitive in the detection of MS plaques, but most efforts to use MRI in the diagnosis of MS have been concentrated on brain lesions in spite of their frequent associations with spinal cord involvements. It is concluded from our case studies that MRI coronal or sagittal image is useful in demonstrating the longitudinal distribution of MS spinal cord lesions. In addition, serial observations of T1 relaxation time values of MS plaques may be important in assessing the activity of MS plaques and evaluation of the steroid therapy in MS processes. (author)

  2. Image sequence analysis in nuclear medicine: (1) Parametric imaging using statistical modelling

    International Nuclear Information System (INIS)

    Liehn, J.C.; Hannequin, P.; Valeyre, J.

    1989-01-01

    This is a review of parametric imaging methods on Nuclear Medicine. A Parametric Image is an image in which each pixel value is a function of the value of the same pixel of an image sequence. The Local Model Method is the fitting of each pixel time activity curve by a model which parameter values form the Parametric Images. The Global Model Method is the modelling of the changes between two images. It is applied to image comparison. For both methods, the different models, the identification criterion, the optimization methods and the statistical properties of the images are discussed. The analysis of one or more Parametric Images is performed using 1D or 2D histograms. The statistically significant Parametric Images, (Images of significant Variances, Amplitudes and Differences) are also proposed [fr

  3. Optical cell sorting with multiple imaging modalities

    DEFF Research Database (Denmark)

    Banas, Andrew; Carrissemoux, Caro; Palima, Darwin

    2017-01-01

    healthy cells. With the richness of visual information, a lot of microscopy techniques have been developed and have been crucial in biological studies. To utilize their complementary advantages we adopt both fluorescence and brightfield imaging in our optical cell sorter. Brightfield imaging has...... the advantage of being non-invasive, thus maintaining cell viability. Fluorescence imaging, on the other hand, takes advantages of the chemical specificity of fluorescence markers and can validate machine vision results from brightfield images. Visually identified cells are sorted using optical manipulation...

  4. Image Alignment for Multiple Camera High Dynamic Range Microscopy.

    Science.gov (United States)

    Eastwood, Brian S; Childs, Elisabeth C

    2012-01-09

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability for HDR alignment of three exposure-robust techniques. We conclude that image alignment based on matching feature descriptors extracted from radiant power images from calibrated cameras yields the most accurate and robust solution. We demonstrate the use of this alignment technique in a high dynamic range video microscope that enables live specimen imaging with a greater level of detail than can be captured with a single camera.

  5. Comparison of MRI sequences for evaluation of multiple sclerosis of the cervical spinal cord at 3 T

    International Nuclear Information System (INIS)

    Philpott, Cristina; Brotchie, Peter

    2011-01-01

    Purpose: Debate remains regarding the utility of the traditional STIR (short inversion time recovery) sequence in aiding MRI diagnosis of spinal cord lesions in patients with multiple sclerosis (MS) and this sequence is not included in the current imaging guidelines. A recent study proposed a T1 weighted STIR as a superior alternative to the traditional STIR and T2 fast spin echo (FSE). Thus, the aim of this study was to compare the sensitivity of T2, standard STIR and T1 weighted STIR sequences in the evaluation of MS plaques on our 3 T system. Methods and materials: A retrospective analysis of patients with multiple sclerosis who presented to our institution over a period of 5 months and who had cervical cord lesions was undertaken. Patients had been examined with our institutional protocol which included T2 FSE, STIR and the recommended T1 STIR. Quantitative analysis of the lesions versus background cord using sample T-tests was performed for each sequence, and comparative analysis of the lesion contrast:background cord ratios of the 3 sequences (using two-way ANOVA tests) was performed. Results: The T2 sequence was not as sensitive in detecting lesions versus the traditional STIR and T1 weighted STIR, with 10% of lesions not detected using statistical analysis (p < 0.05). The traditional STIR also demonstrated greater contrast ratios than the T2 sequence (p < 0.05) suggesting increased sensitivity. However, the T1 STIR demonstrated even greater contrast ratios than both the traditional STIR and T2 sequences (p < 0.05). Conclusion: This study confirms earlier findings of the traditional STIRs increased sensitivity versus the T2 sequence. However, the new “T1 weighted STIR” appears to be even more sensitive than both these sequences showing potential promise as an alternative method to monitor demyelinating plaques of MS.

  6. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  7. Selective interferometric imaging of internal multiples

    KAUST Repository

    Zuberi, M. A H; Alkhalifah, Tariq Ali

    2013-01-01

    are required to construct a Green’s function with all the scattered energy. As an alternative, we develop a three-step procedure, which images the first-order internal scattering using the background Green’s function (from the surface to each image point

  8. Seismic reflection imaging, accounting for primary and multiple reflections

    Science.gov (United States)

    Wapenaar, Kees; van der Neut, Joost; Thorbecke, Jan; Broggini, Filippo; Slob, Evert; Snieder, Roel

    2015-04-01

    Imaging of seismic reflection data is usually based on the assumption that the seismic response consists of primary reflections only. Multiple reflections, i.e. waves that have reflected more than once, are treated as primaries and are imaged at wrong positions. There are two classes of multiple reflections, which we will call surface-related multiples and internal multiples. Surface-related multiples are those multiples that contain at least one reflection at the earth's surface, whereas internal multiples consist of waves that have reflected only at subsurface interfaces. Surface-related multiples are the strongest, but also relatively easy to deal with because the reflecting boundary (the earth's surface) is known. Internal multiples constitute a much more difficult problem for seismic imaging, because the positions and properties of the reflecting interfaces are not known. We are developing reflection imaging methodology which deals with internal multiples. Starting with the Marchenko equation for 1D inverse scattering problems, we derived 3D Marchenko-type equations, which relate reflection data at the surface to Green's functions between virtual sources anywhere in the subsurface and receivers at the surface. Based on these equations, we derived an iterative scheme by which these Green's functions can be retrieved from the reflection data at the surface. This iterative scheme requires an estimate of the direct wave of the Green's functions in a background medium. Note that this is precisely the same information that is also required by standard reflection imaging schemes. However, unlike in standard imaging, our iterative Marchenko scheme retrieves the multiple reflections of the Green's functions from the reflection data at the surface. For this, no knowledge of the positions and properties of the reflecting interfaces is required. Once the full Green's functions are retrieved, reflection imaging can be carried out by which the primaries and multiples are

  9. Magnetic resonance imaging in the diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Kato, Hiroyuki; Takase, Sadao; Ichikawa, Nobumichi; Yamada, Kenji; Matsuzawa, Taiju.

    1987-01-01

    Seventeen patients with multiple sclerosis (MS), 11 clinically definite and 6 probable MS, were studied using magnetic resonance imaging (MRI) and other diagnostic techniques including cerebrospinal fluid (CSF) analysis, evoked potentials (EP) and CT. The MRI imager was operated at 0.14 tesla. The Carr-Purcell-Meiboom-Gill pulse sequence was employed and multiple spin echoes were acquired. T 1 and T 2 relaxation times of the MS plaques were calculated. Incidence of MS plaque detection was 82 % in MRI (100 % in definite MS and 50 % in probable MS). Incidence of abnormality was 65 % in CSF analysis (IgG, oligoclonal bands and myelin basic protein), 63 % in EP (auditory evoked brainstem response and somatosensory evoked response), and 24 % in CT. Lesion detection by MRI was more frequent when the patient was diagnosed as clinically definite, when the duration of disease was longer or the exacerbation was more frequent. T 1 and T 2 of the MS plaques were 715 ± 140 msec and 184 ± 42 msec, respectively, and were significantly prolonged compared to normal values (T 1 ; 351 ± 35 msec, T 2 ; 102 ± 12 msec). The relaxation times of the plaques which were detected by CT (T 1 ; 834 ± 106 msec, T 2 ; 216 ± 37 msec) were significantly longer than those which were not detected (T 1 ; 673 ± 128 msec, T 2 ; 165 ± 32 msec). Serial observations of relaxation times showed that they become short as time passes after the onset of symptoms. As a result, MRI was most sensitive among the diagnostic modalities of MS, and the relaxation times can serve as indices of the activity and severity of the disease. (author)

  10. Minimum TE gradient-recalled phosphorus imaging sequence on a whole-body imager

    International Nuclear Information System (INIS)

    Listerud, J.; Lenkinski, R.E.; Axel, L.

    1989-01-01

    To define the lower limits of spatial resolution in gradient-recalled echo phosphorus studies at 1.5 T, the authors have implemented a phosphorus gradient-recalled imaging sequence on the Signa imager. All gradient ramps for the section-selective rephasing lobe, the phase-encoding pulse, and the dephasing pulse of the frequency-encoding gradient are slowed at the maximal rate. Consequently, with a field of view of 24 cm, an in-plane resolution of 3 cm, an echo appropriately offset, an RF bandwidth of 1.2 KHz, and a section thickness of 5 cm, the echo time may be reduced to 1.35 msec. The reconstruction algorithm has been modified to support oversampled data of low spatial resolution appropriate for phosphorus imaging. The sequence will acquire H-1 images and supports the automatic and manual prescan features of the commercial instrument. To facilitate setup in the phosphorus imaging mode the sequence supports the product spectroscopic mode with a DRESS (depth recalled surface coil spectroscopy) sequence and a section profile sequence for appropriate shimming, receiver characteristics, and averaging requirements. The suitability for adaptation of this sequence to three-dimensional chemical shift imaging is discussed

  11. Real-time multiple image manipulations

    International Nuclear Information System (INIS)

    Arenson, J.S.; Shalev, S.; Legris, J.; Goertzen, Y.

    1984-01-01

    There are many situations in which it is desired to manipulate two or more images under real-time operator control. The authors have investigated a number of such cases in order to determine their value and applicability in clinical medicine and laboratory research. Several examples are presented in detail. The DICOM-8 video image computer system was used due to its capability of storing two 512 x 512 x 8 bit images and operating on them, and/or an incoming video frame, with any of a number of real time operations including addition, subtraction, inversion, averaging, logical AND, NAND, OR, NOR, NOT, XOR and XNOR, as well as combinations of these. Some applications involve manipulations of or among the stored images. In others, a stored image is used as a mask or template for positioning or adjusting a second image to be grabbed via a video camera. The accuracy of radiotherapy treatment is verified by comparing port films with the original radiographic planning film, which is previously digitized and stored. Moving the port film on the light box while viewing the real-time subtraction image allows for adjustments of zoom, translation and rotation, together with contrast and edge enhancement

  12. OBJECT-SPACE MULTI-IMAGE MATCHING OF MOBILE-MAPPING-SYSTEM IMAGE SEQUENCES

    Directory of Open Access Journals (Sweden)

    Y. C. Chen

    2012-07-01

    Full Text Available This paper proposes an object-space multi-image matching procedure of terrestrial MMS (Mobile Mapping System image sequences to determine the coordinates of an object point automatically and reliably. This image matching procedure can be applied to find conjugate points of MMS image sequences efficiently. Conventional area-based image matching methods are not reliable to deliver accurate matching results for this application due to image scale variations, viewing angle variations, and object occlusions. In order to deal with these three matching problems, an object space multi-image matching is proposed. A modified NCC (Normalized Cross Correlation coefficient is proposed to measure the similarity of image patches. A modified multi-window matching procedure will also be introduced to solve the problem of object occlusion. A coarse-to-fine procedure with a combination of object-space multi-image matching and multi-window matching is adopted. The proposed procedure has been implemented for the purpose of matching terrestrial MMS image sequences. The ratio of correct matches of this experiment was about 80 %. By providing an approximate conjugate point in an overlapping image manually, most of the incorrect matches could be fixed properly and the ratio of correct matches was improved up to 98 %.

  13. PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Heil, Alexander; Bendszus, Martin; Prager, Marcel; Heiland, Sabine; Schwindling, Franz Sebastian; Rammelsberg, Peter; Nittka, Mathias; Grodzki, David

    2017-01-01

    Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. (orig.)

  14. PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hilgenfeld, Tim; Heil, Alexander; Bendszus, Martin [Heidelberg University Hospital, Department of Neuroradiology, Heidelberg (Germany); Prager, Marcel; Heiland, Sabine [Heidelberg University Hospital, Department of Neuroradiology, Heidelberg (Germany); Heidelberg University Hospital, Section of Experimental Radiology, Heidelberg (Germany); Schwindling, Franz Sebastian; Rammelsberg, Peter [Heidelberg University Hospital, Department of Prosthodontics, Heidelberg (Germany); Nittka, Mathias; Grodzki, David [Siemens Healthcare GmbH, Erlangen (Germany)

    2017-12-15

    Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. (orig.)

  15. Pareto-depth for multiple-query image retrieval.

    Science.gov (United States)

    Hsiao, Ko-Jen; Calder, Jeff; Hero, Alfred O

    2015-02-01

    Most content-based image retrieval systems consider either one single query, or multiple queries that include the same object or represent the same semantic information. In this paper, we consider the content-based image retrieval problem for multiple query images corresponding to different image semantics. We propose a novel multiple-query information retrieval algorithm that combines the Pareto front method with efficient manifold ranking. We show that our proposed algorithm outperforms state of the art multiple-query retrieval algorithms on real-world image databases. We attribute this performance improvement to concavity properties of the Pareto fronts, and prove a theoretical result that characterizes the asymptotic concavity of the fronts.

  16. RNAblueprint: flexible multiple target nucleic acid sequence design.

    Science.gov (United States)

    Hammer, Stefan; Tschiatschek, Birgit; Flamm, Christoph; Hofacker, Ivo L; Findeiß, Sven

    2017-09-15

    Realizing the value of synthetic biology in biotechnology and medicine requires the design of molecules with specialized functions. Due to its close structure to function relationship, and the availability of good structure prediction methods and energy models, RNA is perfectly suited to be synthetically engineered with predefined properties. However, currently available RNA design tools cannot be easily adapted to accommodate new design specifications. Furthermore, complicated sampling and optimization methods are often developed to suit a specific RNA design goal, adding to their inflexibility. We developed a C ++  library implementing a graph coloring approach to stochastically sample sequences compatible with structural and sequence constraints from the typically very large solution space. The approach allows to specify and explore the solution space in a well defined way. Our library also guarantees uniform sampling, which makes optimization runs performant by not only avoiding re-evaluation of already found solutions, but also by raising the probability of finding better solutions for long optimization runs. We show that our software can be combined with any other software package to allow diverse RNA design applications. Scripting interfaces allow the easy adaption of existing code to accommodate new scenarios, making the whole design process very flexible. We implemented example design approaches written in Python to demonstrate these advantages. RNAblueprint , Python implementations and benchmark datasets are available at github: https://github.com/ViennaRNA . s.hammer@univie.ac.at, ivo@tbi.univie.ac.at or sven@tbi.univie.ac.at. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  17. INTEGRATED FUSION METHOD FOR MULTIPLE TEMPORAL-SPATIAL-SPECTRAL IMAGES

    Directory of Open Access Journals (Sweden)

    H. Shen

    2012-08-01

    Full Text Available Data fusion techniques have been widely researched and applied in remote sensing field. In this paper, an integrated fusion method for remotely sensed images is presented. Differently from the existed methods, the proposed method has the performance to integrate the complementary information in multiple temporal-spatial-spectral images. In order to represent and process the images in one unified framework, two general image observation models are firstly presented, and then the maximum a posteriori (MAP framework is used to set up the fusion model. The gradient descent method is employed to solve the fused image. The efficacy of the proposed method is validated using simulated images.

  18. Benefits and limitations of imaging multiples: Interferometric and resonant migration

    KAUST Repository

    Guo, Bowen; Yu, Jianhua; Huang, Yunsong; Hanafy, Sherif M.; Schuster, Gerard T.

    2015-01-01

    The benefits and limitations of imaging multiples are reviewed for interferometric migration and resonant migration. Synthetic and field data examples are used to characterize the effectiveness of the methods.

  19. Benefits and limitations of imaging multiples: Interferometric and resonant migration

    KAUST Repository

    Guo, Bowen

    2015-07-01

    The benefits and limitations of imaging multiples are reviewed for interferometric migration and resonant migration. Synthetic and field data examples are used to characterize the effectiveness of the methods.

  20. Multiple sclerosis and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Truyen, Luc; Gheuens, Jan; Parizel, P.M.; Van de Vyver, F.L.; Martin, J.J.

    1991-01-01

    In previous studies it has been showed that standardization of the MRI examination and inclusion of sagittal proton-density images results in higher sensitivity and improved correlation with clinical findings. In the present study the usefulness of this MRI protocol in the follow-up of MS patients is evaluated. (author). 5 refs.; 2 figs.; 1 tab

  1. Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

    International Nuclear Information System (INIS)

    Bink, Andrea; Gaa, Jochen; Lanfermann, Heinrich; Zanella, Friedhelm E.; Schmitt, Melanie; Mugler, John P.

    2006-01-01

    The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected. (orig.)

  2. Multiple event 2D image intensifier scintillation detector

    International Nuclear Information System (INIS)

    Thieberger, P.; Wegner, H.E.; Lee, R.C.

    1981-01-01

    An image intensifier scintillation detector has been developed for the simultaneous detection of multiple light or heavy ions down to very low energies. The relative X-Y positions of each ion are read out by digitization of a television image of the light amplified scintillations. The maximum data rate is limited by the present television scan speed to 15 multiple events per second and to about one event second by the microcomputer presently used to store and process the data. (orig.)

  3. Compression and Processing of Space Image Sequences of Northern Lights and Sprites

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Martins, Bo; Jensen, Ole Riis

    1999-01-01

    Compression of image sequences of auroral activity as northern lights and thunderstorms with sprites is investigated.......Compression of image sequences of auroral activity as northern lights and thunderstorms with sprites is investigated....

  4. Placental fetal stem segmentation in a sequence of histology images

    Science.gov (United States)

    Athavale, Prashant; Vese, Luminita A.

    2012-02-01

    Recent research in perinatal pathology argues that analyzing properties of the placenta may reveal important information on how certain diseases progress. One important property is the structure of the placental fetal stems. Analysis of the fetal stems in a placenta could be useful in the study and diagnosis of some diseases like autism. To study the fetal stem structure effectively, we need to automatically and accurately track fetal stems through a sequence of digitized hematoxylin and eosin (H&E) stained histology slides. There are many problems in successfully achieving this goal. A few of the problems are: large size of images, misalignment of the consecutive H&E slides, unpredictable inaccuracies of manual tracing, very complicated texture patterns of various tissue types without clear characteristics, just to name a few. In this paper we propose a novel algorithm to achieve automatic tracing of the fetal stem in a sequence of H&E images, based on an inaccurate manual segmentation of a fetal stem in one of the images. This algorithm combines global affine registration, local non-affine registration and a novel 'dynamic' version of the active contours model without edges. We first use global affine image registration of all the images based on displacement, scaling and rotation. This gives us approximate location of the corresponding fetal stem in the image that needs to be traced. We then use the affine registration algorithm "locally" near this location. At this point, we use a fast non-affine registration based on L2-similarity measure and diffusion regularization to get a better location of the fetal stem. Finally, we have to take into account inaccuracies in the initial tracing. This is achieved through a novel dynamic version of the active contours model without edges where the coefficients of the fitting terms are computed iteratively to ensure that we obtain a unique stem in the segmentation. The segmentation thus obtained can then be used as an

  5. Magnetic resonance imaging of the spine in multiple myeloma

    International Nuclear Information System (INIS)

    Tanaka, Masato; Nakahara, Shinnosuke; Koura, Hiroshi; Kai, Nobuo; Asaumi, Koji; Tanaka, Shunsuke; Sezaki, Tatsuo; Fukuda, Shunichi; Sunami, Kazutaka

    2000-01-01

    The characteristics of diagnostic imaging of the spine in multiple myeloma were examined. Twenty-one patients with stage II-III multiple myeloma (male=12, female=9, mean age=64) underwent MRI of the spine. Other diagnostic imaging modalities used in these patients included, CT bone scintigraphy, and radiography. All images of the spine were assessed and compared with the MRI images. The type of progression was evaluated based on the tumor distribution classification established by Sezaki. T1-weighted images of all 21 patients showed low signals in vertebral bodies, including 14 cases with a focal low signal intensity and 7 cases with diffuse low signal intensity. On the T2-weighted images, 15 of the 21 cases (71%) showed equivalent signals, while T2*-weighted images obtained by the field-echo method yielded high signals in 10 out of 11 cases. It was difficult to differentiate between senile osteoporosis and multiple myeloma by MRI, but CT images clearly distinguished between them. The results suggested that fat-suppressive T1-contrast images and T2*-weighted images are useful in detecting lesions, especially focal low signal intensity lesions. Patients with the multiple-lesion-tumor type of disease were more likely to develop paralysis more than those with the diffuse myeloproliferative type. Thus, the tumor distribution classification established by Sezaki was useful in considering radiotherapy for the treatment of patients at risk of paralysis. Bone scintigraphy revealed accumulation only in spinal lesions caused by compression fractures, while CT appeared to be useful in localizing the diffuse myeloproliferative type of lesions. The problems associated with diagnosis by MRI are differentiation of multiple myeloma from senile osteoporosis and metastatic bone tumors of the spine. There are few specific findings in multiple myeloma. (K.H.)

  6. High intensity region segmentation in MR imaging of multiple sclerosis

    International Nuclear Information System (INIS)

    Rodrigo, F; Filipuzzi, M; Graffigna, J P; Isoardi, R; Noceti, M

    2013-01-01

    Numerous pathologies are often manifest in Magnetic Resonance Imaging (MRI) as hyperintense or bright regions as compared to normal tissue. It is of particular interest to develop an algorithm to detect, identify and define those Regions of Interest (ROI) when analyzing MRI studies, particularly for lesions of Multiple Sclerosis (MS). The objective of this study is to analyze those parameters which optimize segmentation of the areas of interest. To establish which areas should be considered as hyperintense regions, we developed a database (DB), with studies of patients diagnosed with MS. This disease causes axonal demyelination and it is expressed as bright regions in PD, T2 and FLAIR MRI sequences. Thus, with more than 4300 hyperintense regions validated by an expert physician, an algorithm was developed to detect such spots, approximating the results the expert obtained. Alongside these hyperintense lesion regions, it also detected bone regions with high intensity levels, similar to the intensity of the lesions, but with other features that allow a good differentiation.The algorithm will then detect ROIs with similar intensity levels and performs classification through data mining techniques

  7. Magnetic resonance imaging in the diagnostics of multiple sclerosis

    International Nuclear Information System (INIS)

    Larsen, J.P.; Tjoerstad, K.; Kaass, B.; Oedegaard, H.

    1987-01-01

    Multiple sclerosis is an important and frequent neurological disease and the diagnosis might be difficult. The clinical criteria of multiple sclerosis and the role of laboratory examinations in the diagnosis of the disease are discussed. In particular the help offered by the magnetic resonance imaging method is the subject of this paper. Three patients are reported and discussed

  8. Human genome sequencing with direct x-ray holographic imaging

    International Nuclear Information System (INIS)

    Rhodes, C.K.

    1993-01-01

    Direct holographic imaging of biological materials is widely applicable to the study of the structure, properties and action of genetic material. This particular application involves the sequencing of the human genome where prospective genomic imaging technology is composed of three subtechnologies, name an x-ray holographic camera, suitable chemistry and enzymology for the preparation of tagged DNA samples, and the illuminator in the form of an x-ray laser. We report appropriate x-ray camera, embodied by the instrument developed by MCR, is available and that suitable chemical and enzymatic procedures exist for the preparation of the necessary tagged DNA strands. Concerning the future development of the x-ray illuminator. We find that a practical small scale x-ray light source is indeed feasible. This outcome requires the use of unconventional physical processes in order to achieve the necessary power-compression in the amplifying medium. The understanding of these new physical mechanisms is developing rapidly. Importantly, although the x-ray source does not currently exist, the understanding of these new physical mechanisms is developing rapidly and the research has established the basic scaling laws that will determine the properties of the x-ray illuminator. When this x-ray source becomes available, an extremely rapid and cost effective instrument for 3-D imaging of biological materials can be applied to a wide range of biological structural assays, including the base-pair sequencing of the human genome and many questions regarding its higher levels of organization

  9. An efficient multiple exposure image fusion in JPEG domain

    Science.gov (United States)

    Hebbalaguppe, Ramya; Kakarala, Ramakrishna

    2012-01-01

    In this paper, we describe a method to fuse multiple images taken with varying exposure times in the JPEG domain. The proposed algorithm finds its application in HDR image acquisition and image stabilization for hand-held devices like mobile phones, music players with cameras, digital cameras etc. Image acquisition at low light typically results in blurry and noisy images for hand-held camera's. Altering camera settings like ISO sensitivity, exposure times and aperture for low light image capture results in noise amplification, motion blur and reduction of depth-of-field respectively. The purpose of fusing multiple exposures is to combine the sharp details of the shorter exposure images with high signal-to-noise-ratio (SNR) of the longer exposure images. The algorithm requires only a single pass over all images, making it efficient. It comprises of - sigmoidal boosting of shorter exposed images, image fusion, artifact removal and saturation detection. Algorithm does not need more memory than a single JPEG macro block to be kept in memory making it feasible to be implemented as the part of a digital cameras hardware image processing engine. The Artifact removal step reuses the JPEGs built-in frequency analysis and hence benefits from the considerable optimization and design experience that is available for JPEG.

  10. MR imaging of multiple sclerosis in the cervical cord

    International Nuclear Information System (INIS)

    Shakudo, Miyuki; Takemoto, Kazumasa; Inoue, Yuichi; Onoyama, Yasuto; Nishimura, Masataka; Fujita, Masayuki.

    1987-01-01

    This is a case of a 34-year-old woman with multiple sclerosis (MS) in whom an enlarged cervical spinal cord with long T 1 and T 2 relaxation times was demonstrated on MR images. This report seems to be the first description of MR imaging of MS with an enlarged spinal cord. (author)

  11. The linearized inversion of the generalized interferometric multiple imaging

    KAUST Repository

    Aldawood, Ali

    2016-09-06

    The generalized interferometric multiple imaging (GIMI) procedure can be used to image duplex waves and other higher order internal multiples. Imaging duplex waves could help illuminate subsurface zones that are not easily illuminated by primaries such as vertical and nearly vertical fault planes, and salt flanks. To image first-order internal multiple, the GIMI framework consists of three datuming steps, followed by applying the zero-lag cross-correlation imaging condition. However, the standard GIMI procedure yields migrated images that suffer from low spatial resolution, migration artifacts, and cross-talk noise. To alleviate these problems, we propose a least-squares GIMI framework in which we formulate the first two steps as a linearized inversion problem when imaging first-order internal multiples. Tests on synthetic datasets demonstrate the ability to localize subsurface scatterers in their true positions, and delineate a vertical fault plane using the proposed method. We, also, demonstrate the robustness of the proposed framework when imaging the scatterers or the vertical fault plane with erroneous migration velocities.

  12. The linearized inversion of the generalized interferometric multiple imaging

    KAUST Repository

    Aldawood, Ali; Hoteit, Ibrahim; Alkhalifah, Tariq Ali

    2016-01-01

    such as vertical and nearly vertical fault planes, and salt flanks. To image first-order internal multiple, the GIMI framework consists of three datuming steps, followed by applying the zero-lag cross-correlation imaging condition. However, the standard GIMI

  13. Multiple images of our galaxy in closed, multiply connected cosmologies

    International Nuclear Information System (INIS)

    Fagundes, H.V.

    1985-01-01

    Friedmanian cosmology with multiply connected spatial sections allows multiple images of cosmic sources, in particular of the galaxy itself. This is illustrated with a specific example of a closed hyperbolic model and a brief mention of a spherical model. Such images may eventually become observable (or recognized as such), thus providing a new test of relativistic cosmology. (Author) [pt

  14. Moving target detection based on temporal-spatial information fusion for infrared image sequences

    Science.gov (United States)

    Toing, Wu-qin; Xiong, Jin-yu; Zeng, An-jun; Wu, Xiao-ping; Xu, Hao-peng

    2009-07-01

    Moving target detection and localization is one of the most fundamental tasks in visual surveillance. In this paper, through analyzing the advantages and disadvantages of the traditional approaches about moving target detection, a novel approach based on temporal-spatial information fusion is proposed for moving target detection. The proposed method combines the spatial feature in single frame and the temporal properties within multiple frames of an image sequence of moving target. First, the method uses the spatial image segmentation for target separation from background and uses the local temporal variance for extracting targets and wiping off the trail artifact. Second, the logical "and" operator is used to fuse the temporal and spatial information. In the end, to the fusion image sequence, the morphological filtering and blob analysis are used to acquire exact moving target. The algorithm not only requires minimal computation and memory but also quickly adapts to the change of background and environment. Comparing with other methods, such as the KDE, the Mixture of K Gaussians, etc., the simulation results show the proposed method has better validity and higher adaptive for moving target detection, especially in infrared image sequences with complex illumination change, noise change, and so on.

  15. Autonomy of image and use of single or multiple sense modalities in original verbal image production.

    Science.gov (United States)

    Khatena, J

    1978-06-01

    The use of a single or of multiple sense modalities in the production of original verbal images as related to autonomy of imagery was explored. 72 college adults were administered Onomatopoeia and Images and the Gordon Test of Visual Imagery Control. A modified scoring procedure for the Gordon scale differentiated imagers who were moderate or low in autonomy. The two groups produced original verbal images using multiple sense modalities more frequently than a single modality.

  16. Superresolution restoration of an image sequence: adaptive filtering approach.

    Science.gov (United States)

    Elad, M; Feuer, A

    1999-01-01

    This paper presents a new method based on adaptive filtering theory for superresolution restoration of continuous image sequences. The proposed methodology suggests least squares (LS) estimators which adapt in time, based on adaptive filters, least mean squares (LMS) or recursive least squares (RLS). The adaptation enables the treatment of linear space and time-variant blurring and arbitrary motion, both of them assumed known. The proposed new approach is shown to be of relatively low computational requirements. Simulations demonstrating the superresolution restoration algorithms are presented.

  17. Magnetic nanoparticle imaging using multiple electron paramagnetic resonance activation sequences

    International Nuclear Information System (INIS)

    Coene, A.; Dupré, L.; Crevecoeur, G.

    2015-01-01

    Magnetic nanoparticles play an important role in several biomedical applications such as hyperthermia, drug targeting, and disease detection. To realize an effective working of these applications, the spatial distribution of the particles needs to be accurately known, in a non-invasive way. Electron Paramagnetic Resonance (EPR) is a promising and sensitive measurement technique for recovering these distributions. In the conventional approach, EPR is applied with a homogeneous magnetic field. In this paper, we employ different heterogeneous magnetic fields that allow to stabilize the solution of the associated inverse problem and to obtain localized spatial information. A comparison is made between the two approaches and our novel adaptation shows an average increase in reconstruction quality by 5% and is 12 times more robust towards noise. Furthermore, our approach allows to speed up the EPR measurements while still obtaining reconstructions with an improved accuracy and noise robustness compared to homogeneous EPR

  18. Structured diagnostic imaging in patients with multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Rieger, J.; Rock, C.; Pfeifer, K.J.; Reiser, M.; Kanz, K.G.

    2002-01-01

    Purpose. Development of a concept for structured diagnostic imaging in patients with multiple trauma.Material and methods. Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented.Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality.Results. This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients.Conclusion. Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality. (orig.) [de

  19. Simultaneous Structural Variation Discovery in Multiple Paired-End Sequenced Genomes

    Science.gov (United States)

    Hormozdiari, Fereydoun; Hajirasouliha, Iman; McPherson, Andrew; Eichler, Evan E.; Sahinalp, S. Cenk

    Next generation sequencing technologies have been decreasing the costs and increasing the world-wide capacity for sequence production at an unprecedented rate, making the initiation of large scale projects aiming to sequence almost 2000 genomes [1]. Structural variation detection promises to be one of the key diagnostic tools for cancer and other diseases with genomic origin. In this paper, we study the problem of detecting structural variation events in two or more sequenced genomes through high throughput sequencing . We propose to move from the current model of (1) detecting genomic variations in single next generation sequenced (NGS) donor genomes independently, and (2) checking whether two or more donor genomes indeed agree or disagree on the variations (in this paper we name this framework Independent Structural Variation Discovery and Merging - ISV&M), to a new model in which we detect structural variation events among multiple genomes simultaneously.

  20. Multiple Access Interference Reduction Using Received Response Code Sequence for DS-CDMA UWB System

    Science.gov (United States)

    Toh, Keat Beng; Tachikawa, Shin'ichi

    This paper proposes a combination of novel Received Response (RR) sequence at the transmitter and a Matched Filter-RAKE (MF-RAKE) combining scheme receiver system for the Direct Sequence-Code Division Multiple Access Ultra Wideband (DS-CDMA UWB) multipath channel model. This paper also demonstrates the effectiveness of the RR sequence in Multiple Access Interference (MAI) reduction for the DS-CDMA UWB system. It suggests that by using conventional binary code sequence such as the M sequence or the Gold sequence, there is a possibility of generating extra MAI in the UWB system. Therefore, it is quite difficult to collect the energy efficiently although the RAKE reception method is applied at the receiver. The main purpose of the proposed system is to overcome the performance degradation for UWB transmission due to the occurrence of MAI during multiple accessing in the DS-CDMA UWB system. The proposed system improves the system performance by improving the RAKE reception performance using the RR sequence which can reduce the MAI effect significantly. Simulation results verify that significant improvement can be obtained by the proposed system in the UWB multipath channel models.

  1. Simultaneous ECG-gated PET imaging of multiple mice

    International Nuclear Information System (INIS)

    Seidel, Jurgen; Bernardo, Marcelino L.; Wong, Karen J.; Xu, Biying; Williams, Mark R.; Kuo, Frank; Jagoda, Elaine M.; Basuli, Falguni; Li, Changhui; Griffiths, Gary L.

    2014-01-01

    Introduction: We describe and illustrate a method for creating ECG-gated PET images of the heart for each of several mice imaged at the same time. The method is intended to increase “throughput” in PET research studies of cardiac dynamics or to obtain information derived from such studies, e.g. tracer concentration in end-diastolic left ventricular blood. Methods: An imaging bed with provisions for warming, anesthetic delivery, etc., was fabricated by 3D printing to allow simultaneous PET imaging of two side-by-side mice. After electrode attachment, tracer injection and placement of the animals in the scanner field of view, ECG signals from each animal were continuously analyzed and independent trigger markers generated whenever an R-wave was detected in each signal. PET image data were acquired in “list” mode and these trigger markers were inserted into this list along with the image data. Since each mouse is in a different spatial location in the FOV, sorting of these data using trigger markers first from one animal and then the other yields two independent and correctly formed ECG-gated image sequences that reflect the dynamical properties of the heart during an “average” cardiac cycle. Results: The described method yields two independent ECG-gated image sequences that exhibit the expected properties in each animal, e.g. variation of the ventricular cavity volumes from maximum to minimum and back during the cardiac cycle in the processed animal with little or no variation in these volumes during the cardiac cycle in the unprocessed animal. Conclusion: ECG-gated image sequences for each of several animals can be created from a single list mode data collection using the described method. In principle, this method can be extended to more than two mice (or other animals) and to other forms of physiological gating, e.g. respiratory gating, when several subjects are imaged at the same time

  2. Magnetic resonance imaging in clinically-definite multiple sclerosis

    International Nuclear Information System (INIS)

    Noakes, J.B.; Herkes, G.K.; Frith, J.A.

    1990-01-01

    Forty-two patients with clinically-definite multiple sclerosis were examined by magnetic resonance imaging using a 1.5-T instrument. Magnetic resonance imaging detected an abnormality in 90% of patients. In four patients, no lesions were demonstrated. The number, size and site of the lesions by magnetic resonance imaging were compared with the patients' clinical status and other variables. The Kurtzke disability status scale score increased in patients with corpus callosum atrophy, brainstem and basal ganglia lesions, and correlated with the total number of lesions. No correlation was shown between the findings of magnetic resonance imaging and disease duration, age, sex or pattern-reversal visual-evoked potentials. The variety of magnetic resonance images that could be obtained in patients with clinically-definite multiple sclerosis is highlighted. 24 refs., 8 figs., 1 tab

  3. Safety Assessment of Advanced Imaging Sequences II: Simulations

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2016-01-01

    .6%, when using the impulse response of the probe estimated from an independent measurement. The accuracy is increased to between -22% to 24.5% for MI and between -33.2% to 27.0% for Ispta.3, when using the pressure response measured at a single point to scale the simulation. The spatial distribution of MI...... Mechanical Index (MI) and Ispta.3 as required by FDA. The method is performed on four different imaging schemes and compared to measurements conducted using the SARUS experimental scanner. The sequences include focused emissions with an F-number of 2 with 64 elements that generate highly non-linear fields....... The simulation time is between 0.67 ms to 2.8 ms per emission and imaging point, making it possible to simulate even complex emission sequences in less than 1 s for a single spatial position. The linear simulations yield a relative accuracy on MI between -12.1% to 52.3% and for Ispta.3 between -38.6% to 62...

  4. Correction of projective distortion in long-image-sequence mosaics without prior information

    Science.gov (United States)

    Yang, Chenhui; Mao, Hongwei; Abousleman, Glen; Si, Jennie

    2010-04-01

    Image mosaicking is the process of piecing together multiple video frames or still images from a moving camera to form a wide-area or panoramic view of the scene being imaged. Mosaics have widespread applications in many areas such as security surveillance, remote sensing, geographical exploration, agricultural field surveillance, virtual reality, digital video, and medical image analysis, among others. When mosaicking a large number of still images or video frames, the quality of the resulting mosaic is compromised by projective distortion. That is, during the mosaicking process, the image frames that are transformed and pasted to the mosaic become significantly scaled down and appear out of proportion with respect to the mosaic. As more frames continue to be transformed, important target information in the frames can be lost since the transformed frames become too small, which eventually leads to the inability to continue further. Some projective distortion correction techniques make use of prior information such as GPS information embedded within the image, or camera internal and external parameters. Alternatively, this paper proposes a new algorithm to reduce the projective distortion without using any prior information whatsoever. Based on the analysis of the projective distortion, we approximate the projective matrix that describes the transformation between image frames using an affine model. Using singular value decomposition, we can deduce the affine model scaling factor that is usually very close to 1. By resetting the image scale of the affine model to 1, the transformed image size remains unchanged. Even though the proposed correction introduces some error in the image matching, this error is typically acceptable and more importantly, the final mosaic preserves the original image size after transformation. We demonstrate the effectiveness of this new correction algorithm on two real-world unmanned air vehicle (UAV) sequences. The proposed method is

  5. DIALIGN: multiple DNA and protein sequence alignment at BiBiServ.

    OpenAIRE

    Morgenstern, Burkhard

    2004-01-01

    DIALIGN is a widely used software tool for multiple DNA and protein sequence alignment. The program combines local and global alignment features and can therefore be applied to sequence data that cannot be correctly aligned by more traditional approaches. DIALIGN is available online through Bielefeld Bioinformatics Server (BiBiServ). The downloadable version of the program offers several new program features. To compare the output of different alignment programs, we developed the program AltA...

  6. Recommendations to improve imaging and analysis of brain lesion load and atrophy in longitudinal studies of multiple sclerosis

    DEFF Research Database (Denmark)

    Vrenken, H; Jenkinson, M; Horsfield, M A

    2013-01-01

    resonance image analysis methods for assessing brain lesion load and atrophy, this paper makes recommendations to improve these measures for longitudinal studies of MS. Briefly, they are (1) images should be acquired using 3D pulse sequences, with near-isotropic spatial resolution and multiple image......Focal lesions and brain atrophy are the most extensively studied aspects of multiple sclerosis (MS), but the image acquisition and analysis techniques used can be further improved, especially those for studying within-patient changes of lesion load and atrophy longitudinally. Improved accuracy...

  7. DIALIGN P: Fast pair-wise and multiple sequence alignment using parallel processors

    Directory of Open Access Journals (Sweden)

    Kaufmann Michael

    2004-09-01

    Full Text Available Abstract Background Parallel computing is frequently used to speed up computationally expensive tasks in Bioinformatics. Results Herein, a parallel version of the multi-alignment program DIALIGN is introduced. We propose two ways of dividing the program into independent sub-routines that can be run on different processors: (a pair-wise sequence alignments that are used as a first step to multiple alignment account for most of the CPU time in DIALIGN. Since alignments of different sequence pairs are completely independent of each other, they can be distributed to multiple processors without any effect on the resulting output alignments. (b For alignments of large genomic sequences, we use a heuristics by splitting up sequences into sub-sequences based on a previously introduced anchored alignment procedure. For our test sequences, this combined approach reduces the program running time of DIALIGN by up to 97%. Conclusions By distributing sub-routines to multiple processors, the running time of DIALIGN can be crucially improved. With these improvements, it is possible to apply the program in large-scale genomics and proteomics projects that were previously beyond its scope.

  8. Supervised detection of exoplanets in high-contrast imaging sequences

    Science.gov (United States)

    Gomez Gonzalez, C. A.; Absil, O.; Van Droogenbroeck, M.

    2018-06-01

    Context. Post-processing algorithms play a key role in pushing the detection limits of high-contrast imaging (HCI) instruments. State-of-the-art image processing approaches for HCI enable the production of science-ready images relying on unsupervised learning techniques, such as low-rank approximations, for generating a model point spread function (PSF) and subtracting the residual starlight and speckle noise. Aims: In order to maximize the detection rate of HCI instruments and survey campaigns, advanced algorithms with higher sensitivities to faint companions are needed, especially for the speckle-dominated innermost region of the images. Methods: We propose a reformulation of the exoplanet detection task (for ADI sequences) that builds on well-established machine learning techniques to take HCI post-processing from an unsupervised to a supervised learning context. In this new framework, we present algorithmic solutions using two different discriminative models: SODIRF (random forests) and SODINN (neural networks). We test these algorithms on real ADI datasets from VLT/NACO and VLT/SPHERE HCI instruments. We then assess their performances by injecting fake companions and using receiver operating characteristic analysis. This is done in comparison with state-of-the-art ADI algorithms, such as ADI principal component analysis (ADI-PCA). Results: This study shows the improved sensitivity versus specificity trade-off of the proposed supervised detection approach. At the diffraction limit, SODINN improves the true positive rate by a factor ranging from 2 to 10 (depending on the dataset and angular separation) with respect to ADI-PCA when working at the same false-positive level. Conclusions: The proposed supervised detection framework outperforms state-of-the-art techniques in the task of discriminating planet signal from speckles. In addition, it offers the possibility of re-processing existing HCI databases to maximize their scientific return and potentially improve

  9. RevTrans: multiple alignment of coding DNA from aligned amino acid sequences

    DEFF Research Database (Denmark)

    Wernersson, Rasmus; Pedersen, Anders Gorm

    2003-01-01

    The simple fact that proteins are built from 20 amino acids while DNA only contains four different bases, means that the 'signal-to-noise ratio' in protein sequence alignments is much better than in alignments of DNA. Besides this information-theoretical advantage, protein alignments also benefit...... proteins. It is therefore preferable to align coding DNA at the amino acid level and it is for this purpose we have constructed the program RevTrans. RevTrans constructs a multiple DNA alignment by: (i) translating the DNA; (ii) aligning the resulting peptide sequences; and (iii) building a multiple DNA...

  10. Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences

    International Nuclear Information System (INIS)

    Kim, Seong Hyun; Choi, Dongil; Lim, Hyo K.; Kim, Min Ju; Jang, Kyung Mi; Kim, Seung Hoon; Lee, Won Jae; Lee, Jongmee; Jeon, Yong Hwan; Lim, Jae Hoon

    2006-01-01

    Objective: To compare the diagnostic performance of a variety of magnetic resonance imaging (MRI) sequences, in order to identify the most effective ferucarbotran-enhanced sequence for the detection of multiple small hepatic VX2 carcinomas in rabbits. Methods: Fifteen rabbits with experimentally induced 135 VX2 carcinomas in the liver underwent ferucarbotran-enhanced MRI using the following nine pulse sequences: a fat-suppressed fast spin-echo (FSE) sequence with two echo times (TE) (proton density- and T2-weighted images), four different T2*-weighted fast multiplanar GRASS (gradient-recalled acquisition in the steady state) (FMPGR) with the combination of three TEs (9, 12, 15 ms, respectively) and two flip angles (20 deg., 80 deg., respectively), T2*-weighted fast multiplanar spoiled GRASS (FMPSPGR), T1-weighted FMPSPGR, and dynamic T1-weighted FMPSPGR. All images were reviewed by three radiologists with quantitative and qualitative analysis. Results: Tumor-to-liver contrast-to-noise ratio of the proton density-weighted FSE sequence was significantly higher than those of the others (p o ) images were superior to those of the others and for the detection of very small hepatic tumors of less than 5 mm, the sensitivities of these sequences were less than 30%. Conclusion: Ferucarbotran-enhanced T2- and proton density-weighted FSE and T2*-weighed FMPGR (TE/flip angle, 12/20 o ) images were found to be the most effective pulse sequences for the detection of multiple small hepatic VX2 carcinomas but these sequences were limited in the detection of very small hepatic tumors of less than 5 mm in size

  11. Optical orthogonal code-division multiple-access system - Part 2: Multibits/sequence-period OOCDMA

    Science.gov (United States)

    Kwon, Hyuck M.

    1994-08-01

    In a recently proposed optical orthogonal code division multiple-access (OOCDMA) system, one bit of user's data is transmitted per sequence-period, and a threshold is employed for the final bit decision. In this paper, a system that can transmit multibits per sequence-period is introduced, and avalanche photodiode (APD) noise, thermal noise, and interference, are included. This system, derived by exploiting orthogonal properties of the OOCDMA code sequence and using a maximum search (instead of a threshold) in the final decision, is log(sub 2) F times higher in throughput, where F is sequence-period. For example, four orders of magnitude are better in bit error probability at - 56 dBW received laser power, with F = 1000 chips, 10 'marks' in a sequence, and 10 users of 30 Mb/s data rate for one-bit/sequence-period and 270 Mb/s data rate for multibits/sequence-period system. Furthermore, an exact analysis is performed for the log(sub 2)F bits/sequence-period system with a hard-limiter placed before the receiver, and its performance is compared to the performance without hard-limiter, for the chip-synchronous case. The improvement from using a hard-limiter is significant in the log(sub 2)F bits/sequence-period OCCDMA system.

  12. Lossless Image Compression Based on Multiple-Tables Arithmetic Coding

    Directory of Open Access Journals (Sweden)

    Rung-Ching Chen

    2009-01-01

    Full Text Available This paper is intended to present a lossless image compression method based on multiple-tables arithmetic coding (MTAC method to encode a gray-level image f. First, the MTAC method employs a median edge detector (MED to reduce the entropy rate of f. The gray levels of two adjacent pixels in an image are usually similar. A base-switching transformation approach is then used to reduce the spatial redundancy of the image. The gray levels of some pixels in an image are more common than those of others. Finally, the arithmetic encoding method is applied to reduce the coding redundancy of the image. To promote high performance of the arithmetic encoding method, the MTAC method first classifies the data and then encodes each cluster of data using a distinct code table. The experimental results show that, in most cases, the MTAC method provides a higher efficiency in use of storage space than the lossless JPEG2000 does.

  13. Utilization of multiple frequencies in 3D nonlinear microwave imaging

    DEFF Research Database (Denmark)

    Jensen, Peter Damsgaard; Rubæk, Tonny; Mohr, Johan Jacob

    2012-01-01

    The use of multiple frequencies in a nonlinear microwave algorithm is considered. Using multiple frequencies allows for obtaining the improved resolution available at the higher frequencies while retaining the regularizing effects of the lower frequencies. However, a number of different challenges...... at lower frequencies are used as starting guesses for reconstructions at higher frequencies. The performance is illustrated using simulated 2-D data and data obtained with the 3-D DTU microwave imaging system....

  14. Increasing Benefit of Magnetic Resonance Imaging in Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Pyhtinen, J.; Karttunen, A.; Tikkakoski, T. [Radiologian Klinikka, Oulu (Finland)

    2006-11-15

    Magnetic resonance imaging (MRI) has emerged as an essential tool of multiple sclerosis (MS) diagnosis and has opened up completely new prospects in MS research and treatment trials. It is a sensitive method that gives direct evidence of tissue pathology and has greatly increased our knowledge of MS. In clinical work, MRI is used to confirm and exclude the diagnosis of MS. The international recommendation is that every suspected MS patient should undergo at least one brain MRI. T2-weighted images are the standard tool in clinical work, and functional imaging methods are mainly used in MS research. The subtypes and the course of the disease cause variation in MRI findings. Here, we present a general overview of MR findings in MS. Brain, magnetic resonance imaging, multiple sclerosis, spinal cord.

  15. Increasing Benefit of Magnetic Resonance Imaging in Multiple Sclerosis

    International Nuclear Information System (INIS)

    Pyhtinen, J.; Karttunen, A.; Tikkakoski, T.

    2006-01-01

    Magnetic resonance imaging (MRI) has emerged as an essential tool of multiple sclerosis (MS) diagnosis and has opened up completely new prospects in MS research and treatment trials. It is a sensitive method that gives direct evidence of tissue pathology and has greatly increased our knowledge of MS. In clinical work, MRI is used to confirm and exclude the diagnosis of MS. The international recommendation is that every suspected MS patient should undergo at least one brain MRI. T2-weighted images are the standard tool in clinical work, and functional imaging methods are mainly used in MS research. The subtypes and the course of the disease cause variation in MRI findings. Here, we present a general overview of MR findings in MS. Brain, magnetic resonance imaging, multiple sclerosis, spinal cord

  16. Significance of multiple scattering in imaging through turbid media

    International Nuclear Information System (INIS)

    Zardecki, A.; Gerstl, S.A.W.

    1986-01-01

    The degradation of image quality in a turbid medium is analyzed within the framework of the small-angle approximation, the diffusion approximation, and a rigorous two-dimensional radiative transfer equation. These three approaches allow us to emphasize different aspects of the imaging problem when multiple scattering effects are important. For a medium with a forward-peaked phase function, the separation of multiple scattering into a series of scatterings of various order provides a fruitful technique. The use of the diffusion approximation and transport theory extends the determination of the modulation transfer function to a turbid medium with an arbitrary degree of anisotropy

  17. System and method for image registration of multiple video streams

    Science.gov (United States)

    Dillavou, Marcus W.; Shum, Phillip Corey; Guthrie, Baron L.; Shenai, Mahesh B.; Deaton, Drew Steven; May, Matthew Benton

    2018-02-06

    Provided herein are methods and systems for image registration from multiple sources. A method for image registration includes rendering a common field of interest that reflects a presence of a plurality of elements, wherein at least one of the elements is a remote element located remotely from another of the elements and updating the common field of interest such that the presence of the at least one of the elements is registered relative to another of the elements.

  18. High-field MR imaging of spinal cord multiple sclerosis

    International Nuclear Information System (INIS)

    De La Paz, R.L.; Floris, R.; Norman, D.; Enzmann, D.R.

    1987-01-01

    Fifty-one high-field MR imaging studies (1.5 T, General Electric Signa) of the spinal cord were performed in 42 patients (27 female, 15 male; mean age, 40 years) with clinically definitive (n = 34) or probable (n = 8) multiple sclerosis and suspected spinal cord lesions. MR imaging showed focal spinal cord abnormalities in 38 (75%) of 51 studies. T2-weighted images were abnormal (showing foci of high signal intensity) in 38 studies, T1-weighted images were abnormal (showing areas of low signal intensity or mass effect) in 16 (42%) of 38, and GRASS images were abnormal (showing foci of high signal intensity) in 9 (82%) of 11 cases. Brain MR imaging showed periventricular lesions typical of multiple sclerosis in 34 (81%) of 42 studies. Spinal cord studies were positive in eight cases with normal brain MR images, and brain studies were positive in 13 instances of normal spinal cord MR images. Four lesions were at the cervicomedullary junction, 44 in the cervical spinal cord, and three in the thoracic cord. Mass effect in cord lesions, simulating neoplasm, was seen in seven patients during the acute symptomatic phase. Serial studies in three patients with decreasing symptoms showed a reduction after 3-4 weeks and resolution of the mass effect after 2-6 months

  19. Holistic and component plant phenotyping using temporal image sequence.

    Science.gov (United States)

    Das Choudhury, Sruti; Bashyam, Srinidhi; Qiu, Yumou; Samal, Ashok; Awada, Tala

    2018-01-01

    Image-based plant phenotyping facilitates the extraction of traits noninvasively by analyzing large number of plants in a relatively short period of time. It has the potential to compute advanced phenotypes by considering the whole plant as a single object (holistic phenotypes) or as individual components, i.e., leaves and the stem (component phenotypes), to investigate the biophysical characteristics of the plants. The emergence timing, total number of leaves present at any point of time and the growth of individual leaves during vegetative stage life cycle of the maize plants are significant phenotypic expressions that best contribute to assess the plant vigor. However, image-based automated solution to this novel problem is yet to be explored. A set of new holistic and component phenotypes are introduced in this paper. To compute the component phenotypes, it is essential to detect the individual leaves and the stem. Thus, the paper introduces a novel method to reliably detect the leaves and the stem of the maize plants by analyzing 2-dimensional visible light image sequences captured from the side using a graph based approach. The total number of leaves are counted and the length of each leaf is measured for all images in the sequence to monitor leaf growth. To evaluate the performance of the proposed algorithm, we introduce University of Nebraska-Lincoln Component Plant Phenotyping Dataset (UNL-CPPD) and provide ground truth to facilitate new algorithm development and uniform comparison. The temporal variation of the component phenotypes regulated by genotypes and environment (i.e., greenhouse) are experimentally demonstrated for the maize plants on UNL-CPPD. Statistical models are applied to analyze the greenhouse environment impact and demonstrate the genetic regulation of the temporal variation of the holistic phenotypes on the public dataset called Panicoid Phenomap-1. The central contribution of the paper is a novel computer vision based algorithm for

  20. Particle tracking from image sequences of complex plasma crystals

    International Nuclear Information System (INIS)

    Hadziavdic, Vedad; Melandsoe, Frank; Hanssen, Alfred

    2006-01-01

    In order to gather information about the physics of the complex plasma crystals from the experimental data, particles have to be tracked through a sequence of images. An application of the Kalman filter for that purpose is presented, using a one-dimensional approximation of the particle dynamics as a model for the filter. It is shown that Kalman filter is capable of tracking dust particles even with high levels of measurement noise. An inherent part of the Kalman filter, the innovation process, can be used to estimate values of the physical system parameters from the experimental data. The method is shown to be able to estimate the characteristic oscillation frequency from noisy data

  1. Design of multiple sequence alignment algorithms on parallel, distributed memory supercomputers.

    Science.gov (United States)

    Church, Philip C; Goscinski, Andrzej; Holt, Kathryn; Inouye, Michael; Ghoting, Amol; Makarychev, Konstantin; Reumann, Matthias

    2011-01-01

    The challenge of comparing two or more genomes that have undergone recombination and substantial amounts of segmental loss and gain has recently been addressed for small numbers of genomes. However, datasets of hundreds of genomes are now common and their sizes will only increase in the future. Multiple sequence alignment of hundreds of genomes remains an intractable problem due to quadratic increases in compute time and memory footprint. To date, most alignment algorithms are designed for commodity clusters without parallelism. Hence, we propose the design of a multiple sequence alignment algorithm on massively parallel, distributed memory supercomputers to enable research into comparative genomics on large data sets. Following the methodology of the sequential progressiveMauve algorithm, we design data structures including sequences and sorted k-mer lists on the IBM Blue Gene/P supercomputer (BG/P). Preliminary results show that we can reduce the memory footprint so that we can potentially align over 250 bacterial genomes on a single BG/P compute node. We verify our results on a dataset of E.coli, Shigella and S.pneumoniae genomes. Our implementation returns results matching those of the original algorithm but in 1/2 the time and with 1/4 the memory footprint for scaffold building. In this study, we have laid the basis for multiple sequence alignment of large-scale datasets on a massively parallel, distributed memory supercomputer, thus enabling comparison of hundreds instead of a few genome sequences within reasonable time.

  2. Fast T1-weighted imaging using GRASE sequence for the female pelvis

    International Nuclear Information System (INIS)

    Dohke, Masako; Watanabe, Yuji; Kumashiro, Masayuki; Amoh, Yoshiki; Ishimori, Takayoshi; Oda, Kazushige; Okumura, Akira; Koike, Shinji; Dodo, Yoshihiro

    1998-01-01

    GRASE sequence, a combination of TSE and gradient echo, has been developed as a fast T 2 -weighted imaging technique. We have modified the GRASE sequence to be used for fast T 1 -weighted imaging of the female pelvis. In this article, we compared image quality and incidence of artifacts between T 1 -weighted GRASE images and conventional T 1 -weighted SE images. In a phantom study, signal-to-noise ratio was inferior in the GRASE images relative to corresponding on SE images. Susceptibility and chemical shift artifacts seen in GRASE images were seen with almost equal incidence in SE and TSE images. In a clinical study, we compared GRASE images with SE images in six patients with endometrial cysts and four patients with dermoid cysts. The overall image quality obtained with GRASE sequence was satisfactory in all patients and was almost identical with that obtained with SE sequence. GRASE images demonstrated endometrial cysts and dermoid cysts as clearly as did SE images. T 1 -weighted GRASE imaging, however, has a relatively long TE (35 ms) for T 1 -weighted images, which makes the signal intensity of urine and uterine endometrium with long T 2 values higher than in SE images. In conclusion, GRASE sequence can be used for fast T 1 -weighted imaging of the female pelvis because of short imaging time. (author)

  3. Challenges in clinical studies with multiple imaging probes

    International Nuclear Information System (INIS)

    Krohn, Kenneth A.; O'Sullivan, Finbarr; Crowley, John; Eary, Janet F.; Linden, Hannah M.; Link, Jeanne M.; Mankoff, David A.; Muzi, Mark; Rajendran, Joseph G.; Spence, Alexander M.; Swanson, Kristin R.

    2007-01-01

    This article addresses two related issues: (a) When a new imaging agent is proposed, how does the imager integrate it with other biomarkers, either sampled or imaged? (b) When we have multiple imaging agents, is the information additive or duplicative and how is this objectively determined? Molecular biology is leading to new treatment options with reduced normal tissue toxicity, and imaging should have a role in objectively evaluating new treatments. There are two roles for molecular characterization of disease. Molecular imaging measurements before therapy help predict the aggressiveness of disease and identify therapeutic targets and, therefore, help choose the optimal therapy for an individual. Measurements of specific biochemical processes made during or after therapy should be sensitive measures of tumor response. The rules of evidence are not fully developed for the prognostic role of imaging biomarkers, but the potential of molecular imaging provides compelling motivation to push forward with convincing validation studies. New imaging procedures need to be characterized for their effectiveness under realistic clinical conditions to improve the management of patients and achieve a better outcome. The purpose of this article is to promote a critical discussion within the molecular imaging community because our future value to the overall biomedical community will be in supporting better treatment outcomes rather than in detection

  4. Sedimentation and lithostratigraphy of the Vuosaari multiple till sequence in Helsinki, southern Finland

    Directory of Open Access Journals (Sweden)

    Hirvas, H.

    1995-12-01

    Full Text Available A multiple till sequence interbedded with sorted sediments has been investigated at Vuosaari, Helsinki, Finland. The investigation was carried out using standard sedimentological procedures combined with microfossil analysis in order to determine the genesis of the exposed sediments. This evidence is used to correlate lithostratigraphically the sequence with adjacent multiple till sequences in other parts of southern Finland (south of the Salpausselkä zone. It is concluded that all three till beds at Vuosaari are of basal origin that were laid down by separate ice flow phases. In contrast two rhythmite beds between the tills are thought to have been deposited in open water. The sediments at Vuosaari may have been laid down during the Weichselian glaciation although it is also possible that the lowermost till bed represents Saalian till.

  5. DendroBLAST: approximate phylogenetic trees in the absence of multiple sequence alignments.

    Science.gov (United States)

    Kelly, Steven; Maini, Philip K

    2013-01-01

    The rapidly growing availability of genome information has created considerable demand for both fast and accurate phylogenetic inference algorithms. We present a novel method called DendroBLAST for reconstructing phylogenetic dendrograms/trees from protein sequences using BLAST. This method differs from other methods by incorporating a simple model of sequence evolution to test the effect of introducing sequence changes on the reliability of the bipartitions in the inferred tree. Using realistic simulated sequence data we demonstrate that this method produces phylogenetic trees that are more accurate than other commonly-used distance based methods though not as accurate as maximum likelihood methods from good quality multiple sequence alignments. In addition to tests on simulated data, we use DendroBLAST to generate input trees for a supertree reconstruction of the phylogeny of the Archaea. This independent analysis produces an approximate phylogeny of the Archaea that has both high precision and recall when compared to previously published analysis of the same dataset using conventional methods. Taken together these results demonstrate that approximate phylogenetic trees can be produced in the absence of multiple sequence alignments, and we propose that these trees will provide a platform for improving and informing downstream bioinformatic analysis. A web implementation of the DendroBLAST method is freely available for use at http://www.dendroblast.com/.

  6. DendroBLAST: approximate phylogenetic trees in the absence of multiple sequence alignments.

    Directory of Open Access Journals (Sweden)

    Steven Kelly

    Full Text Available The rapidly growing availability of genome information has created considerable demand for both fast and accurate phylogenetic inference algorithms. We present a novel method called DendroBLAST for reconstructing phylogenetic dendrograms/trees from protein sequences using BLAST. This method differs from other methods by incorporating a simple model of sequence evolution to test the effect of introducing sequence changes on the reliability of the bipartitions in the inferred tree. Using realistic simulated sequence data we demonstrate that this method produces phylogenetic trees that are more accurate than other commonly-used distance based methods though not as accurate as maximum likelihood methods from good quality multiple sequence alignments. In addition to tests on simulated data, we use DendroBLAST to generate input trees for a supertree reconstruction of the phylogeny of the Archaea. This independent analysis produces an approximate phylogeny of the Archaea that has both high precision and recall when compared to previously published analysis of the same dataset using conventional methods. Taken together these results demonstrate that approximate phylogenetic trees can be produced in the absence of multiple sequence alignments, and we propose that these trees will provide a platform for improving and informing downstream bioinformatic analysis. A web implementation of the DendroBLAST method is freely available for use at http://www.dendroblast.com/.

  7. Applying Agrep to r-NSA to solve multiple sequences approximate matching.

    Science.gov (United States)

    Ni, Bing; Wong, Man-Hon; Lam, Chi-Fai David; Leung, Kwong-Sak

    2014-01-01

    This paper addresses the approximate matching problem in a database consisting of multiple DNA sequences, where the proposed approach applies Agrep to a new truncated suffix array, r-NSA. The construction time of the structure is linear to the database size, and the computations of indexing a substring in the structure are constant. The number of characters processed in applying Agrep is analysed theoretically, and the theoretical upper-bound can approximate closely the empirical number of characters, which is obtained through enumerating the characters in the actual structure built. Experiments are carried out using (synthetic) random DNA sequences, as well as (real) genome sequences including Hepatitis-B Virus and X-chromosome. Experimental results show that, compared to the straight-forward approach that applies Agrep to multiple sequences individually, the proposed approach solves the matching problem in much shorter time. The speed-up of our approach depends on the sequence patterns, and for highly similar homologous genome sequences, which are the common cases in real-life genomes, it can be up to several orders of magnitude.

  8. Fat-saturated post gadolinium T1 imaging of the brain in multiple sclerosis

    International Nuclear Information System (INIS)

    Al-Saeed, Osama; Sheikh, Mehraj; Ismail, Mohammed; Athyal, Reji

    2011-01-01

    Background Magnetic resonance imaging (MRI) is of vital importance in the diagnosis and follow-up of patients with multiple sclerosis (MS). Imaging sequences better demonstrating enhancing lesions can help in detecting active MS plaques. Purpose To evaluate the role of fat-saturated gadolinium-enhanced T1-weighted (T1W) images of the brain in MS and to assess the benefit of performing this additional sequence in the detection of enhancing lesions. Material and Methods In a prospective study over a six-month period, 70 consecutive patients with clinically diagnosed MS were enrolled. These constituted 14 male and 56 female patients between the ages of 21 and 44 years. All the patients underwent brain MRIs on a 1.5 Tesla Magnet. Gadolinium-enhanced T1 images with and without fat saturation were compared and results were recorded and analyzed using a conspicuity score and McNemar test. Results There were a total of 157 lesions detected in 70 patients on post-contrast T1W fat-saturated images compared with 139 lesions seen on the post-contrast T1W fast spin-echo (FSE) images. This was because 18 of the lesions (11.5%) were only seen on the fat-saturated images. In addition, 15 lesions were more conspicuous on the fat saturation sequence (9.5%). The total conspicuity score obtained, including all the lesions, was 2.24 +/-0.60 (SD). Using the two-tailed McNemar test for quantitative analysis, the P value obtained was <0.0001. Conclusion T1W fat-saturated gadolinium-enhanced images show better lesion enhancement than T1W images without fat saturation

  9. Automatic plankton image classification combining multiple view features via multiple kernel learning.

    Science.gov (United States)

    Zheng, Haiyong; Wang, Ruchen; Yu, Zhibin; Wang, Nan; Gu, Zhaorui; Zheng, Bing

    2017-12-28

    Plankton, including phytoplankton and zooplankton, are the main source of food for organisms in the ocean and form the base of marine food chain. As the fundamental components of marine ecosystems, plankton is very sensitive to environment changes, and the study of plankton abundance and distribution is crucial, in order to understand environment changes and protect marine ecosystems. This study was carried out to develop an extensive applicable plankton classification system with high accuracy for the increasing number of various imaging devices. Literature shows that most plankton image classification systems were limited to only one specific imaging device and a relatively narrow taxonomic scope. The real practical system for automatic plankton classification is even non-existent and this study is partly to fill this gap. Inspired by the analysis of literature and development of technology, we focused on the requirements of practical application and proposed an automatic system for plankton image classification combining multiple view features via multiple kernel learning (MKL). For one thing, in order to describe the biomorphic characteristics of plankton more completely and comprehensively, we combined general features with robust features, especially by adding features like Inner-Distance Shape Context for morphological representation. For another, we divided all the features into different types from multiple views and feed them to multiple classifiers instead of only one by combining different kernel matrices computed from different types of features optimally via multiple kernel learning. Moreover, we also applied feature selection method to choose the optimal feature subsets from redundant features for satisfying different datasets from different imaging devices. We implemented our proposed classification system on three different datasets across more than 20 categories from phytoplankton to zooplankton. The experimental results validated that our system

  10. Shadow Areas Robust Matching Among Image Sequence in Planetary Landing

    Science.gov (United States)

    Ruoyan, Wei; Xiaogang, Ruan; Naigong, Yu; Xiaoqing, Zhu; Jia, Lin

    2017-01-01

    In this paper, an approach for robust matching shadow areas in autonomous visual navigation and planetary landing is proposed. The approach begins with detecting shadow areas, which are extracted by Maximally Stable Extremal Regions (MSER). Then, an affine normalization algorithm is applied to normalize the areas. Thirdly, a descriptor called Multiple Angles-SIFT (MA-SIFT) that coming from SIFT is proposed, the descriptor can extract more features of an area. Finally, for eliminating the influence of outliers, a method of improved RANSAC based on Skinner Operation Condition is proposed to extract inliers. At last, series of experiments are conducted to test the performance of the approach this paper proposed, the results show that the approach can maintain the matching accuracy at a high level even the differences among the images are obvious with no attitude measurements supplied.

  11. SINA: accurate high-throughput multiple sequence alignment of ribosomal RNA genes.

    Science.gov (United States)

    Pruesse, Elmar; Peplies, Jörg; Glöckner, Frank Oliver

    2012-07-15

    In the analysis of homologous sequences, computation of multiple sequence alignments (MSAs) has become a bottleneck. This is especially troublesome for marker genes like the ribosomal RNA (rRNA) where already millions of sequences are publicly available and individual studies can easily produce hundreds of thousands of new sequences. Methods have been developed to cope with such numbers, but further improvements are needed to meet accuracy requirements. In this study, we present the SILVA Incremental Aligner (SINA) used to align the rRNA gene databases provided by the SILVA ribosomal RNA project. SINA uses a combination of k-mer searching and partial order alignment (POA) to maintain very high alignment accuracy while satisfying high throughput performance demands. SINA was evaluated in comparison with the commonly used high throughput MSA programs PyNAST and mothur. The three BRAliBase III benchmark MSAs could be reproduced with 99.3, 97.6 and 96.1 accuracy. A larger benchmark MSA comprising 38 772 sequences could be reproduced with 98.9 and 99.3% accuracy using reference MSAs comprising 1000 and 5000 sequences. SINA was able to achieve higher accuracy than PyNAST and mothur in all performed benchmarks. Alignment of up to 500 sequences using the latest SILVA SSU/LSU Ref datasets as reference MSA is offered at http://www.arb-silva.de/aligner. This page also links to Linux binaries, user manual and tutorial. SINA is made available under a personal use license.

  12. Abdominal MR imaging using a HASTE sequence : image comparison on the different echo times

    International Nuclear Information System (INIS)

    Park, Kwang Bo; Lee, Moon Gyu; Lim, Tae Hwan; Jeong, Yoong Ki; Ha, Hyun Kwon; Kim, Pyo Nyun; Auh, Yong Ho

    1999-01-01

    To determine the optimal parameters of abdominal HASTE imaging by means of a comparison of intermediate and long TE (echo time). We evaluated 30 consecutive patients who had undergone liver MR during a three-month period. Twelve patients were diagnosed as normal, four as having liver cirrhosis, and 14 were found to be suffering form hepatic hemangioma. On the basis of measured signal intensity of the liver, spleen, pancreas and gallbladder, and of fat, muscle, hemangioma, and background, we calculated the ratios of signal to noise (S/N), signal difference to noise (SD/N), and signal intensity (SI). Image quality was compared using these three ratios, and using two HASTE sequences with TEs of 90 msec and 134 msec, images were qualitatively evaluated. S/N ratio of the liver was higher when TE was 90 msec(p<.05), though S/N, SD/N and SI rations of the spleen, gallbladder, and pancreas-and of hemangiom-were higher when TE was 134 msec (p<.05). However, in muscle, all these three ratios were higher at a TE of 90 msec. SD/N ratio and SI of fat were higher at a TE of 134 msec. Overall image quality was better at a TE of 134 msec than at one of 90msec. A HASTE sequence with a TE of 134msec showed greater tissue contrast and stronger T2-weighted images than one with a TE of 90msec

  13. Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Bomas, Bettina; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-12-01

    Improved real-time cardiac magnetic resonance (CMR) sequences have currently been introduced, but so far only limited practical experience exists. This study aimed at image reconstruction optimization and clinical validation of a new highly accelerated real-time cine SPARSE-SENSE sequence. Left ventricular (LV) short-axis stacks of a real-time free-breathing SPARSE-SENSE sequence with high spatiotemporal resolution and of a standard segmented cine SSFP sequence were acquired at 1.5 T in 11 volunteers and 15 patients. To determine the optimal iterations, all volunteers' SPARSE-SENSE images were reconstructed using 10-200 iterations, and contrast ratios, image entropies, and reconstruction times were assessed. Subsequently, the patients' SPARSE-SENSE images were reconstructed with the clinically optimal iterations. LV volumetric values were evaluated and compared between both sequences. Sufficient image quality and acceptable reconstruction times were achieved when using 80 iterations. Bland-Altman plots and Passing-Bablok regression showed good agreement for all volumetric parameters. 80 iterations are recommended for iterative SPARSE-SENSE image reconstruction in clinical routine. Real-time cine SPARSE-SENSE yielded comparable volumetric results as the current standard SSFP sequence. Due to its intrinsic low image acquisition times, real-time cine SPARSE-SENSE imaging with iterative image reconstruction seems to be an attractive alternative for LV function analysis. • A highly accelerated real-time CMR sequence using SPARSE-SENSE was evaluated. • SPARSE-SENSE allows free breathing in real-time cardiac cine imaging. • For clinically optimal SPARSE-SENSE image reconstruction, 80 iterations are recommended. • Real-time SPARSE-SENSE imaging yielded comparable volumetric results as the reference SSFP sequence. • The fast SPARSE-SENSE sequence is an attractive alternative to standard SSFP sequences.

  14. Generalized internal multiple imaging (GIMI) using Feynman-like diagrams

    KAUST Repository

    Zuberi, M. A. H.

    2014-05-19

    Single scattering events recorded in surface seismic data do not fully illuminate the subsurface structure, especially if it is complicated. In such cases, multiple internal scatterings (internal multiples) can help improve the illumination. We devise a generalized internal multiple imaging (GIMI) procedure that maps internal multiple energy to their true location with a relatively mild addition to the computational cost. GIMI theory relies heavily on seismic interferometry, which often involves cumbersome algebra, especially when one is dealing with high-order terms in the perturbation series. To make the derivations, and inference of the results easier, we introduce Feynman-like diagrams to represent different terms of the perturbation series (solution to the Lippman–Schwinger equation). The rules we define for the diagrams allow operations like convolution and cross-correlation in the series to be compressed in diagram form. The application of the theory to a double scattering example demonstrates the power of the method.

  15. Generalized internal multiple imaging (GIMI) using Feynman-like diagrams

    KAUST Repository

    Zuberi, M. A. H.; Alkhalifah, Tariq Ali

    2014-01-01

    Single scattering events recorded in surface seismic data do not fully illuminate the subsurface structure, especially if it is complicated. In such cases, multiple internal scatterings (internal multiples) can help improve the illumination. We devise a generalized internal multiple imaging (GIMI) procedure that maps internal multiple energy to their true location with a relatively mild addition to the computational cost. GIMI theory relies heavily on seismic interferometry, which often involves cumbersome algebra, especially when one is dealing with high-order terms in the perturbation series. To make the derivations, and inference of the results easier, we introduce Feynman-like diagrams to represent different terms of the perturbation series (solution to the Lippman–Schwinger equation). The rules we define for the diagrams allow operations like convolution and cross-correlation in the series to be compressed in diagram form. The application of the theory to a double scattering example demonstrates the power of the method.

  16. Abbreviated protocol for breast MRI: Are multiple sequences needed for cancer detection?

    International Nuclear Information System (INIS)

    Mango, Victoria L.; Morris, Elizabeth A.; David Dershaw, D.; Abramson, Andrea; Fry, Charles; Moskowitz, Chaya S.; Hughes, Mary; Kaplan, Jennifer; Jochelson, Maxine S.

    2015-01-01

    Highlights: • Abbreviated breast MR demonstrates high sensitivity for breast carcinoma detection. • Time to perform/interpret the abbreviated exam is shorter than a standard MRI exam. • An abbreviated breast MRI could reduce costs and make MRI screening more available. - Abstract: Objective: To evaluate the ability of an abbreviated breast magnetic resonance imaging (MRI) protocol, consisting of a precontrast T1 weighted (T1W) image and single early post-contrast T1W image, to detect breast carcinoma. Materials and methods: A HIPAA compliant Institutional Review Board approved review of 100 consecutive breast MRI examinations in patients with biopsy proven unicentric breast carcinoma. 79% were invasive carcinomas and 21% were ductal carcinoma in situ. Four experienced breast radiologists, blinded to carcinoma location, history and prior examinations, assessed the abbreviated protocol evaluating only the first post-contrast T1W image, post-processed subtracted first post-contrast and subtraction maximum intensity projection images. Detection and localization of tumor were compared to the standard full diagnostic examination consisting of 13 pre-contrast, post-contrast and post-processed sequences. Results: All 100 cancers were visualized on initial reading of the abbreviated protocol by at least one reader. The mean sensitivity for each sequence was 96% for the first post-contrast sequence, 96% for the first post-contrast subtraction sequence and 93% for the subtraction MIP sequence. Within each sequence, there was no significant difference between the sensitivities among the 4 readers (p = 0.471, p = 0.656, p = 0.139). Mean interpretation time was 44 s (range 11–167 s). The abbreviated imaging protocol could be performed in approximately 10–15 min, compared to 30–40 min for the standard protocol. Conclusion: An abbreviated breast MRI protocol allows detection of breast carcinoma. One pre and post-contrast T1W sequence may be adequate for detecting

  17. Abbreviated protocol for breast MRI: Are multiple sequences needed for cancer detection?

    Energy Technology Data Exchange (ETDEWEB)

    Mango, Victoria L., E-mail: vlm2125@columbia.edu [Columbia University Medical Center, Herbert Irving Pavilion, 161 Fort Washington Avenue, 10th Floor, New York, NY 10032 (United States); Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Morris, Elizabeth A., E-mail: morrise@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); David Dershaw, D., E-mail: dershawd@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Abramson, Andrea, E-mail: abramsoa@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Fry, Charles, E-mail: charles_fry@nymc.edu [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); New York Medical College, 40 Sunshine Cottage Rd, Valhalla, NY 10595 (United States); Moskowitz, Chaya S. [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Hughes, Mary, E-mail: hughesm@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Kaplan, Jennifer, E-mail: kaplanj@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Jochelson, Maxine S., E-mail: jochelsm@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States)

    2015-01-15

    Highlights: • Abbreviated breast MR demonstrates high sensitivity for breast carcinoma detection. • Time to perform/interpret the abbreviated exam is shorter than a standard MRI exam. • An abbreviated breast MRI could reduce costs and make MRI screening more available. - Abstract: Objective: To evaluate the ability of an abbreviated breast magnetic resonance imaging (MRI) protocol, consisting of a precontrast T1 weighted (T1W) image and single early post-contrast T1W image, to detect breast carcinoma. Materials and methods: A HIPAA compliant Institutional Review Board approved review of 100 consecutive breast MRI examinations in patients with biopsy proven unicentric breast carcinoma. 79% were invasive carcinomas and 21% were ductal carcinoma in situ. Four experienced breast radiologists, blinded to carcinoma location, history and prior examinations, assessed the abbreviated protocol evaluating only the first post-contrast T1W image, post-processed subtracted first post-contrast and subtraction maximum intensity projection images. Detection and localization of tumor were compared to the standard full diagnostic examination consisting of 13 pre-contrast, post-contrast and post-processed sequences. Results: All 100 cancers were visualized on initial reading of the abbreviated protocol by at least one reader. The mean sensitivity for each sequence was 96% for the first post-contrast sequence, 96% for the first post-contrast subtraction sequence and 93% for the subtraction MIP sequence. Within each sequence, there was no significant difference between the sensitivities among the 4 readers (p = 0.471, p = 0.656, p = 0.139). Mean interpretation time was 44 s (range 11–167 s). The abbreviated imaging protocol could be performed in approximately 10–15 min, compared to 30–40 min for the standard protocol. Conclusion: An abbreviated breast MRI protocol allows detection of breast carcinoma. One pre and post-contrast T1W sequence may be adequate for detecting

  18. SoftSearch: integration of multiple sequence features to identify breakpoints of structural variations.

    Directory of Open Access Journals (Sweden)

    Steven N Hart

    Full Text Available BACKGROUND: Structural variation (SV represents a significant, yet poorly understood contribution to an individual's genetic makeup. Advanced next-generation sequencing technologies are widely used to discover such variations, but there is no single detection tool that is considered a community standard. In an attempt to fulfil this need, we developed an algorithm, SoftSearch, for discovering structural variant breakpoints in Illumina paired-end next-generation sequencing data. SoftSearch combines multiple strategies for detecting SV including split-read, discordant read-pair, and unmated pairs. Co-localized split-reads and discordant read pairs are used to refine the breakpoints. RESULTS: We developed and validated SoftSearch using real and synthetic datasets. SoftSearch's key features are 1 not requiring secondary (or exhaustive primary alignment, 2 portability into established sequencing workflows, and 3 is applicable to any DNA-sequencing experiment (e.g. whole genome, exome, custom capture, etc.. SoftSearch identifies breakpoints from a small number of soft-clipped bases from split reads and a few discordant read-pairs which on their own would not be sufficient to make an SV call. CONCLUSIONS: We show that SoftSearch can identify more true SVs by combining multiple sequence features. SoftSearch was able to call clinically relevant SVs in the BRCA2 gene not reported by other tools while offering significantly improved overall performance.

  19. An intuitive graphical webserver for multiple-choice protein sequence search.

    Science.gov (United States)

    Banky, Daniel; Szalkai, Balazs; Grolmusz, Vince

    2014-04-10

    Every day tens of thousands of sequence searches and sequence alignment queries are submitted to webservers. The capitalized word "BLAST" becomes a verb, describing the act of performing sequence search and alignment. However, if one needs to search for sequences that contain, for example, two hydrophobic and three polar residues at five given positions, the query formation on the most frequently used webservers will be difficult. Some servers support the formation of queries with regular expressions, but most of the users are unfamiliar with their syntax. Here we present an intuitive, easily applicable webserver, the Protein Sequence Analysis server, that allows the formation of multiple choice queries by simply drawing the residues to their positions; if more than one residue are drawn to the same position, then they will be nicely stacked on the user interface, indicating the multiple choice at the given position. This computer-game-like interface is natural and intuitive, and the coloring of the residues makes possible to form queries requiring not just certain amino acids in the given positions, but also small nonpolar, negatively charged, hydrophobic, positively charged, or polar ones. The webserver is available at http://psa.pitgroup.org. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Suitable post processing algorithms for X-ray imaging using oversampled displaced multiple images

    International Nuclear Information System (INIS)

    Thim, J; Reza, S; Nawaz, K; Norlin, B; O'Nils, M; Oelmann, B

    2011-01-01

    X-ray imaging systems such as photon counting pixel detectors have a limited spatial resolution of the pixels, based on the complexity and processing technology of the readout electronics. For X-ray imaging situations where the features of interest are smaller than the imaging system pixel size, and the pixel size cannot be made smaller in the hardware, alternative means of resolution enhancement require to be considered. Oversampling with the usage of multiple displaced images, where the pixels of all images are mapped to a final resolution enhanced image, has proven a viable method of reaching a sub-pixel resolution exceeding the original resolution. The effectiveness of the oversampling method declines with the number of images taken, the sub-pixel resolution increases, but relative to a real reduction of imaging pixel sizes yielding a full resolution image, the perceived resolution from the sub-pixel oversampled image is lower. This is because the oversampling method introduces blurring noise into the mapped final images, and the blurring relative to full resolution images increases with the oversampling factor. One way of increasing the performance of the oversampling method is by sharpening the images in post processing. This paper focus on characterizing the performance increase of the oversampling method after the use of some suitable post processing filters, for digital X-ray images specifically. The results show that spatial domain filters and frequency domain filters of the same type yield indistinguishable results, which is to be expected. The results also show that the effectiveness of applying sharpening filters to oversampled multiple images increase with the number of images used (oversampling factor), leaving 60-80% of the original blurring noise after filtering a 6 x 6 mapped image (36 images taken), where the percentage is depending on the type of filter. This means that the effectiveness of the oversampling itself increase by using sharpening

  1. Textureless Macula Swelling Detection with Multiple Retinal Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Grisan, Enrico [University of Padua, Padua, Italy; Favaro, Paolo [Heriot-Watt University, Edinburgh; Ruggeri, Alfredo [University of Padua, Padua, Italy; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. We also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.

  2. Algorithms for detection of objects in image sequences captured from an airborne imaging system

    Science.gov (United States)

    Kasturi, Rangachar; Camps, Octavia; Tang, Yuan-Liang; Devadiga, Sadashiva; Gandhi, Tarak

    1995-01-01

    This research was initiated as a part of the effort at the NASA Ames Research Center to design a computer vision based system that can enhance the safety of navigation by aiding the pilots in detecting various obstacles on the runway during critical section of the flight such as a landing maneuver. The primary goal is the development of algorithms for detection of moving objects from a sequence of images obtained from an on-board video camera. Image regions corresponding to the independently moving objects are segmented from the background by applying constraint filtering on the optical flow computed from the initial few frames of the sequence. These detected regions are tracked over subsequent frames using a model based tracking algorithm. Position and velocity of the moving objects in the world coordinate is estimated using an extended Kalman filter. The algorithms are tested using the NASA line image sequence with six static trucks and a simulated moving truck and experimental results are described. Various limitations of the currently implemented version of the above algorithm are identified and possible solutions to build a practical working system are investigated.

  3. TurboFold: Iterative probabilistic estimation of secondary structures for multiple RNA sequences

    Directory of Open Access Journals (Sweden)

    Sharma Gaurav

    2011-04-01

    Full Text Available Abstract Background The prediction of secondary structure, i.e. the set of canonical base pairs between nucleotides, is a first step in developing an understanding of the function of an RNA sequence. The most accurate computational methods predict conserved structures for a set of homologous RNA sequences. These methods usually suffer from high computational complexity. In this paper, TurboFold, a novel and efficient method for secondary structure prediction for multiple RNA sequences, is presented. Results TurboFold takes, as input, a set of homologous RNA sequences and outputs estimates of the base pairing probabilities for each sequence. The base pairing probabilities for a sequence are estimated by combining intrinsic information, derived from the sequence itself via the nearest neighbor thermodynamic model, with extrinsic information, derived from the other sequences in the input set. For a given sequence, the extrinsic information is computed by using pairwise-sequence-alignment-based probabilities for co-incidence with each of the other sequences, along with estimated base pairing probabilities, from the previous iteration, for the other sequences. The extrinsic information is introduced as free energy modifications for base pairing in a partition function computation based on the nearest neighbor thermodynamic model. This process yields updated estimates of base pairing probability. The updated base pairing probabilities in turn are used to recompute extrinsic information, resulting in the overall iterative estimation procedure that defines TurboFold. TurboFold is benchmarked on a number of ncRNA datasets and compared against alternative secondary structure prediction methods. The iterative procedure in TurboFold is shown to improve estimates of base pairing probability with each iteration, though only small gains are obtained beyond three iterations. Secondary structures composed of base pairs with estimated probabilities higher than a

  4. Imaging moving objects from multiply scattered waves and multiple sensors

    International Nuclear Information System (INIS)

    Miranda, Analee; Cheney, Margaret

    2013-01-01

    In this paper, we develop a linearized imaging theory that combines the spatial, temporal and spectral components of multiply scattered waves as they scatter from moving objects. In particular, we consider the case of multiple fixed sensors transmitting and receiving information from multiply scattered waves. We use a priori information about the multipath background. We use a simple model for multiple scattering, namely scattering from a fixed, perfectly reflecting (mirror) plane. We base our image reconstruction and velocity estimation technique on a modification of a filtered backprojection method that produces a phase-space image. We plot examples of point-spread functions for different geometries and waveforms, and from these plots, we estimate the resolution in space and velocity. Through this analysis, we are able to identify how the imaging system depends on parameters such as bandwidth and number of sensors. We ultimately show that enhanced phase-space resolution for a distribution of moving and stationary targets in a multipath environment may be achieved using multiple sensors. (paper)

  5. A Stochastic Approach for Blurred Image Restoration and Optical Flow Computation on Field Image Sequence

    Institute of Scientific and Technical Information of China (English)

    高文; 陈熙霖

    1997-01-01

    The blur in target images caused by camera vibration due to robot motion or hand shaking and by object(s) moving in the background scene is different to deal with in the computer vision system.In this paper,the authors study the relation model between motion and blur in the case of object motion existing in video image sequence,and work on a practical computation algorithm for both motion analysis and blut image restoration.Combining the general optical flow and stochastic process,the paper presents and approach by which the motion velocity can be calculated from blurred images.On the other hand,the blurred image can also be restored using the obtained motion information.For solving a problem with small motion limitation on the general optical flow computation,a multiresolution optical flow algoritm based on MAP estimation is proposed. For restoring the blurred image ,an iteration algorithm and the obtained motion velocity are used.The experiment shows that the proposed approach for both motion velocity computation and blurred image restoration works well.

  6. Image Based Solution to Occlusion Problem for Multiple Robots Navigation

    Directory of Open Access Journals (Sweden)

    Taj Mohammad Khan

    2012-04-01

    Full Text Available In machine vision, occlusions problem is always a challenging issue in image based mapping and navigation tasks. This paper presents a multiple view vision based algorithm for the development of occlusion-free map of the indoor environment. The map is assumed to be utilized by the mobile robots within the workspace. It has wide range of applications, including mobile robot path planning and navigation, access control in restricted areas, and surveillance systems. We used wall mounted fixed camera system. After intensity adjustment and background subtraction of the synchronously captured images, the image registration was performed. We applied our algorithm on the registered images to resolve the occlusion problem. This technique works well even in the existence of total occlusion for a longer period.

  7. AlignMiner: a Web-based tool for detection of divergent regions in multiple sequence alignments of conserved sequences

    Directory of Open Access Journals (Sweden)

    Claros M Gonzalo

    2010-06-01

    Full Text Available Abstract Background Multiple sequence alignments are used to study gene or protein function, phylogenetic relations, genome evolution hypotheses and even gene polymorphisms. Virtually without exception, all available tools focus on conserved segments or residues. Small divergent regions, however, are biologically important for specific quantitative polymerase chain reaction, genotyping, molecular markers and preparation of specific antibodies, and yet have received little attention. As a consequence, they must be selected empirically by the researcher. AlignMiner has been developed to fill this gap in bioinformatic analyses. Results AlignMiner is a Web-based application for detection of conserved and divergent regions in alignments of conserved sequences, focusing particularly on divergence. It accepts alignments (protein or nucleic acid obtained using any of a variety of algorithms, which does not appear to have a significant impact on the final results. AlignMiner uses different scoring methods for assessing conserved/divergent regions, Entropy being the method that provides the highest number of regions with the greatest length, and Weighted being the most restrictive. Conserved/divergent regions can be generated either with respect to the consensus sequence or to one master sequence. The resulting data are presented in a graphical interface developed in AJAX, which provides remarkable user interaction capabilities. Users do not need to wait until execution is complete and can.even inspect their results on a different computer. Data can be downloaded onto a user disk, in standard formats. In silico and experimental proof-of-concept cases have shown that AlignMiner can be successfully used to designing specific polymerase chain reaction primers as well as potential epitopes for antibodies. Primer design is assisted by a module that deploys several oligonucleotide parameters for designing primers "on the fly". Conclusions AlignMiner can be used

  8. Quantitative comparison between a multiecho sequence and a single-echo sequence for susceptibility-weighted phase imaging.

    Science.gov (United States)

    Gilbert, Guillaume; Savard, Geneviève; Bard, Céline; Beaudoin, Gilles

    2012-06-01

    The aim of this study was to investigate the benefits arising from the use of a multiecho sequence for susceptibility-weighted phase imaging using a quantitative comparison with a standard single-echo acquisition. Four healthy adult volunteers were imaged on a clinical 3-T system using a protocol comprising two different three-dimensional susceptibility-weighted gradient-echo sequences: a standard single-echo sequence and a multiecho sequence. Both sequences were repeated twice in order to evaluate the local noise contribution by a subtraction of the two acquisitions. For the multiecho sequence, the phase information from each echo was independently unwrapped, and the background field contribution was removed using either homodyne filtering or the projection onto dipole fields method. The phase information from all echoes was then combined using a weighted linear regression. R2 maps were also calculated from the multiecho acquisitions. The noise standard deviation in the reconstructed phase images was evaluated for six manually segmented regions of interest (frontal white matter, posterior white matter, globus pallidus, putamen, caudate nucleus and lateral ventricle). The use of the multiecho sequence for susceptibility-weighted phase imaging led to a reduction of the noise standard deviation for all subjects and all regions of interest investigated in comparison to the reference single-echo acquisition. On average, the noise reduction ranged from 18.4% for the globus pallidus to 47.9% for the lateral ventricle. In addition, the amount of noise reduction was found to be strongly inversely correlated to the estimated R2 value (R=-0.92). In conclusion, the use of a multiecho sequence is an effective way to decrease the noise contribution in susceptibility-weighted phase images, while preserving both contrast and acquisition time. The proposed approach additionally permits the calculation of R2 maps. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Imaging of multiple endocrine neoplasia (MEN II A)

    International Nuclear Information System (INIS)

    Tanaka, Hiroko; Kohno, Atsushi; Nojiri, Yoko

    1995-01-01

    A retrospective review of diagnostic imaging findings of 20 cases of multiple endocrine neoplasia II A (MEN II A) was performed. The characteristic findings of thyroidal medullary carcinomas were relatively well-defined hypo- to isoechoic masses on US and coarse calcifications on plain X-ray. The pheochromocytomas were smaller in size and less enhancing than the sporadic ones, and they revealed marked high intensity on T2WI of MRI. We consider that these imaging findings were useful for the supplementary diagnosis of MEN II A. (author)

  10. Measuring multiple nano-textured areas simultaneously with imaging scatterometry

    DEFF Research Database (Denmark)

    Madsen, Jonas Skovlund; Hansen, Poul Erik; Bilenberg, Brian

    2017-01-01

    and areas with defects can be avoided. These advantages make imaging scatterometry a very effective and user-friendly characterization method and allow us to determine the homogeneity of a nano- Textured surface by performing pixel-wise analyses. In the analysis an inverse modelling approach is used, where...... measured diffraction efficiencies are compared to simulated diffraction efficiencies using a least-square fitting approach. We demonstrate an imaging scatterometry setup built into an optical microscope. The setup is capable of measuring multiple 2D gratings with pitches of 200 nm simultaneously...

  11. An Algorithm for Pedestrian Detection in Multispectral Image Sequences

    Science.gov (United States)

    Kniaz, V. V.; Fedorenko, V. V.

    2017-05-01

    The growing interest for self-driving cars provides a demand for scene understanding and obstacle detection algorithms. One of the most challenging problems in this field is the problem of pedestrian detection. Main difficulties arise from a diverse appearances of pedestrians. Poor visibility conditions such as fog and low light conditions also significantly decrease the quality of pedestrian detection. This paper presents a new optical flow based algorithm BipedDetet that provides robust pedestrian detection on a single-borad computer. The algorithm is based on the idea of simplified Kalman filtering suitable for realization on modern single-board computers. To detect a pedestrian a synthetic optical flow of the scene without pedestrians is generated using slanted-plane model. The estimate of a real optical flow is generated using a multispectral image sequence. The difference of the synthetic optical flow and the real optical flow provides the optical flow induced by pedestrians. The final detection of pedestrians is done by the segmentation of the difference of optical flows. To evaluate the BipedDetect algorithm a multispectral dataset was collected using a mobile robot.

  12. The PETfold and PETcofold web servers for intra- and intermolecular structures of multiple RNA sequences

    DEFF Research Database (Denmark)

    Seemann, Ernst Stefan; Menzel, Karl Peter; Backofen, Rolf

    2011-01-01

    gene. We present web servers to analyze multiple RNA sequences for common RNA structure and for RNA interaction sites. The web servers are based on the recent PET (Probabilistic Evolutionary and Thermodynamic) models PETfold and PETcofold, but add user friendly features ranging from a graphical layer...... to interactive usage of the predictors. Additionally, the web servers provide direct access to annotated RNA alignments, such as the Rfam 10.0 database and multiple alignments of 16 vertebrate genomes with human. The web servers are freely available at: http://rth.dk/resources/petfold/...

  13. Practical multipeptide synthesis: dedicated software for the definition of multiple, overlapping peptides covering polypeptide sequences.

    Science.gov (United States)

    Heegaard, P M; Holm, A; Hagerup, M

    1993-01-01

    A personal computer program for the conversion of linear amino acid sequences to multiple, small, overlapping peptide sequences has been developed. Peptide lengths and "jumps" (the distance between two consecutive overlapping peptides) are defined by the user. To facilitate the use of the program for parallel solid-phase chemical peptide syntheses for the synchronous production of multiple peptides, amino acids at each acylation step are laid out by the program in a convenient standard multi-well setup. Also, the total number of equivalents, as well as the derived amount in milligrams (depend-ending on user-defined equivalent weights and molar surplus), of each amino acid are given. The program facilitates the implementation of multipeptide synthesis, e.g., for the elucidation of polypeptide structure-function relationships, and greatly reduces the risk of introducing mistakes at the planning step. It is written in Pascal and runs on any DOS-based personal computer. No special graphic display is needed.

  14. Monte Carlo simulation of a statistical mechanical model of multiple protein sequence alignment.

    Science.gov (United States)

    Kinjo, Akira R

    2017-01-01

    A grand canonical Monte Carlo (MC) algorithm is presented for studying the lattice gas model (LGM) of multiple protein sequence alignment, which coherently combines long-range interactions and variable-length insertions. MC simulations are used for both parameter optimization of the model and production runs to explore the sequence subspace around a given protein family. In this Note, I describe the details of the MC algorithm as well as some preliminary results of MC simulations with various temperatures and chemical potentials, and compare them with the mean-field approximation. The existence of a two-state transition in the sequence space is suggested for the SH3 domain family, and inappropriateness of the mean-field approximation for the LGM is demonstrated.

  15. Security Analysis of a Block Encryption Algorithm Based on Dynamic Sequences of Multiple Chaotic Systems

    Science.gov (United States)

    Du, Mao-Kang; He, Bo; Wang, Yong

    2011-01-01

    Recently, the cryptosystem based on chaos has attracted much attention. Wang and Yu (Commun. Nonlin. Sci. Numer. Simulat. 14 (2009) 574) proposed a block encryption algorithm based on dynamic sequences of multiple chaotic systems. We analyze the potential flaws in the algorithm. Then, a chosen-plaintext attack is presented. Some remedial measures are suggested to avoid the flaws effectively. Furthermore, an improved encryption algorithm is proposed to resist the attacks and to keep all the merits of the original cryptosystem.

  16. Rapid and Sensitive Isothermal Detection of Nucleic-acid Sequence by Multiple Cross Displacement Amplification

    OpenAIRE

    Yi Wang; Yan Wang; Ai-Jing Ma; Dong-Xun Li; Li-Juan Luo; Dong-Xin Liu; Dong Jin; Kai Liu; Chang-Yun Ye

    2015-01-01

    We have devised a novel amplification strategy based on isothermal strand-displacement polymerization reaction, which was termed multiple cross displacement amplification (MCDA). The approach employed a set of ten specially designed primers spanning ten distinct regions of target sequence and was preceded at a constant temperature (61?65??C). At the assay temperature, the double-stranded DNAs were at dynamic reaction environment of primer-template hybrid, thus the high concentration of primer...

  17. A framework for creating realistic synthetic fluorescence microscopy image sequences

    CSIR Research Space (South Africa)

    Mabaso, M

    2016-02-01

    Full Text Available Fluorescence microscopy imaging is an important tool in modern biological research, allowing insights into the processes of biological systems. Automated image analysis algorithms help in extracting information from these images. Validation...

  18. Parallel multiple instance learning for extremely large histopathology image analysis.

    Science.gov (United States)

    Xu, Yan; Li, Yeshu; Shen, Zhengyang; Wu, Ziwei; Gao, Teng; Fan, Yubo; Lai, Maode; Chang, Eric I-Chao

    2017-08-03

    Histopathology images are critical for medical diagnosis, e.g., cancer and its treatment. A standard histopathology slice can be easily scanned at a high resolution of, say, 200,000×200,000 pixels. These high resolution images can make most existing imaging processing tools infeasible or less effective when operated on a single machine with limited memory, disk space and computing power. In this paper, we propose an algorithm tackling this new emerging "big data" problem utilizing parallel computing on High-Performance-Computing (HPC) clusters. Experimental results on a large-scale data set (1318 images at a scale of 10 billion pixels each) demonstrate the efficiency and effectiveness of the proposed algorithm for low-latency real-time applications. The framework proposed an effective and efficient system for extremely large histopathology image analysis. It is based on the multiple instance learning formulation for weakly-supervised learning for image classification, segmentation and clustering. When a max-margin concept is adopted for different clusters, we obtain further improvement in clustering performance.

  19. Exploring manifold structure of face images via multiple graphs

    KAUST Repository

    Alghamdi, Masheal

    2013-01-01

    Geometric structure in the data provides important information for face image recognition and classification tasks. Graph regularized non-negative matrix factorization (GrNMF) performs well in this task. However, it is sensitive to the parameters selection. Wang et al. proposed multiple graph regularized non-negative matrix factorization (MultiGrNMF) to solve the parameter selection problem by testing it on medical images. In this paper, we introduce the MultiGrNMF algorithm in the context of still face Image classification, and conduct a comparative study of NMF, GrNMF, and MultiGrNMF using two well-known face databases. Experimental results show that MultiGrNMF outperforms NMF and GrNMF for most cases.

  20. Optimized multiple linear mappings for single image super-resolution

    Science.gov (United States)

    Zhang, Kaibing; Li, Jie; Xiong, Zenggang; Liu, Xiuping; Gao, Xinbo

    2017-12-01

    Learning piecewise linear regression has been recognized as an effective way for example learning-based single image super-resolution (SR) in literature. In this paper, we employ an expectation-maximization (EM) algorithm to further improve the SR performance of our previous multiple linear mappings (MLM) based SR method. In the training stage, the proposed method starts with a set of linear regressors obtained by the MLM-based method, and then jointly optimizes the clustering results and the low- and high-resolution subdictionary pairs for regression functions by using the metric of the reconstruction errors. In the test stage, we select the optimal regressor for SR reconstruction by accumulating the reconstruction errors of m-nearest neighbors in the training set. Thorough experimental results carried on six publicly available datasets demonstrate that the proposed SR method can yield high-quality images with finer details and sharper edges in terms of both quantitative and perceptual image quality assessments.

  1. Exploring manifold structure of face images via multiple graphs

    KAUST Repository

    Alghamdi, Masheal

    2013-12-24

    Geometric structure in the data provides important information for face image recognition and classification tasks. Graph regularized non-negative matrix factorization (GrNMF) performs well in this task. However, it is sensitive to the parameters selection. Wang et al. proposed multiple graph regularized non-negative matrix factorization (MultiGrNMF) to solve the parameter selection problem by testing it on medical images. In this paper, we introduce the MultiGrNMF algorithm in the context of still face Image classification, and conduct a comparative study of NMF, GrNMF, and MultiGrNMF using two well-known face databases. Experimental results show that MultiGrNMF outperforms NMF and GrNMF for most cases.

  2. Pulse sequence optimization for superparamagnetic iron oxide-enhaced MR imaging in the detection of hepatic VX2 tumors in rabbits

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Han, Joon Koo; Lee, Kyoung Ho; Kim, Se Hyung; Choi, Byung Ihn; Kim, Tae Kyoung

    2003-01-01

    The purpose of this experimental study was to determine the optimal pulse sequences for SPIO-enhanced MR imaging in the evaluation of multiple hepatic tumors. Twelve rabbits with multiple VX2 liver tumors underwent SPOI-enhanced MRI using the following nine pulse sequences: TSE T2-weighted imaging (T2W1), TSE proton density-weighted imaging(PDWI), and GRE T2*-weighted imaging (T2*W1) with seven different echo times (TE). Liver-lesion contrast-to-noise ratios (CNRs) were calculated, and images were also assessed qualitatively by two radiologists, who reached a consensus as to lesion conspicuity and imaging artifacts using a four-level scale. By means of pathologic correlation, the sensitivity and positive predictive value of each sequence was calculated. TSE T2W1 and long-TE (35 msec) FLASH T2*W1 showed the highest liver-lesion CNR. The best lesion conspicuity was seen at TSE T2W1 and medium-TE (12 msec) GRE T2*W1. Short TE GRE T2*W1 showed the least imaging artifacts. The four sequences which demonstrated the best sensitivity were medium-TE (12 msec), GRE T2*W1 (FLASH, 84%; FISP, 82%), TSE W2T1 (79%), and TSE PDWI (76%). All nine sequences showed overall high positive predictive value (86-97%), with no statistically significant difference (p>0.05). In terms of image quality and the detection of sensitivity, TSE T2W1 and medium TE (12 msec) GRE T2*W1 were the top two pulse sequences among the various sequences used for no SPIO-enhanced MRI. They are thus considered to be optimal sequences for evaluating multiple malignant hepatic tumors

  3. Prognostic value of deep sequencing method for minimal residual disease detection in multiple myeloma

    Science.gov (United States)

    Lahuerta, Juan J.; Pepin, François; González, Marcos; Barrio, Santiago; Ayala, Rosa; Puig, Noemí; Montalban, María A.; Paiva, Bruno; Weng, Li; Jiménez, Cristina; Sopena, María; Moorhead, Martin; Cedena, Teresa; Rapado, Immaculada; Mateos, María Victoria; Rosiñol, Laura; Oriol, Albert; Blanchard, María J.; Martínez, Rafael; Bladé, Joan; San Miguel, Jesús; Faham, Malek; García-Sanz, Ramón

    2014-01-01

    We assessed the prognostic value of minimal residual disease (MRD) detection in multiple myeloma (MM) patients using a sequencing-based platform in bone marrow samples from 133 MM patients in at least very good partial response (VGPR) after front-line therapy. Deep sequencing was carried out in patients in whom a high-frequency myeloma clone was identified and MRD was assessed using the IGH-VDJH, IGH-DJH, and IGK assays. The results were contrasted with those of multiparametric flow cytometry (MFC) and allele-specific oligonucleotide polymerase chain reaction (ASO-PCR). The applicability of deep sequencing was 91%. Concordance between sequencing and MFC and ASO-PCR was 83% and 85%, respectively. Patients who were MRD– by sequencing had a significantly longer time to tumor progression (TTP) (median 80 vs 31 months; P < .0001) and overall survival (median not reached vs 81 months; P = .02), compared with patients who were MRD+. When stratifying patients by different levels of MRD, the respective TTP medians were: MRD ≥10−3 27 months, MRD 10−3 to 10−5 48 months, and MRD <10−5 80 months (P = .003 to .0001). Ninety-two percent of VGPR patients were MRD+. In complete response patients, the TTP remained significantly longer for MRD– compared with MRD+ patients (131 vs 35 months; P = .0009). PMID:24646471

  4. T1 Shortening in the Globus Pallidus after Multiple Administrations of Gadobutrol: Assessment with a Multidynamic Multiecho Sequence.

    Science.gov (United States)

    Kang, Koung Mi; Choi, Seung Hong; Hwang, Moonjung; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho

    2018-04-01

    Purpose To determine the association between the administration of the macrocyclic contrast medium gadobutrol and T1 relaxation time in the brains of patients with normal renal function by using multidynamic multiecho (MDME) magnetic resonance (MR) imaging sequences. Materials and Methods The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. This study included 46 patients (revealed by an electronic medical record search) who had received one or more gadobutrol injections and a maximum of one MR imaging contrast medium injection other than gadobutrol before MDME sequence acquisition. One radiologist performed quantitative analyses of regions of interest on quantitative T1 maps twice to cover the normal-appearing globus pallidus (GP), frontal white matter, frontal cortex, and thalamus. The number of administrations and the cumulative dose of gadobutrol, age, intervals between administrations, sex, and treatment were investigated. Univariable and multivariable linear regression analyses of the T1 values in four brain regions and the GP-to-thalamus signal intensity (SI) ratio were performed. P values of less than the Bonferroni-corrected value of .01 were considered to indicate significant differences. Results Intraobserver reproducibility was good to excellent (intraclass correlation coefficients, 0.62-0.81). Because of high multicollinearity between the number of gadobutrol administrations and accumulated dose (r = 0.96, P .01). Conclusion Multiple exposures to gadobutrol are associated with T1 shortening in the GP. © RSNA, 2017 Online supplemental material is available for this article.

  5. Optical image encryption scheme with multiple light paths based on compressive ghost imaging

    Science.gov (United States)

    Zhu, Jinan; Yang, Xiulun; Meng, Xiangfeng; Wang, Yurong; Yin, Yongkai; Sun, Xiaowen; Dong, Guoyan

    2018-02-01

    An optical image encryption method with multiple light paths is proposed based on compressive ghost imaging. In the encryption process, M random phase-only masks (POMs) are generated by means of logistic map algorithm, and these masks are then uploaded to the spatial light modulator (SLM). The collimated laser light is divided into several beams by beam splitters as it passes through the SLM, and the light beams illuminate the secret images, which are converted into sparse images by discrete wavelet transform beforehand. Thus, the secret images are simultaneously encrypted into intensity vectors by ghost imaging. The distances between the SLM and secret images vary and can be used as the main keys with original POM and the logistic map algorithm coefficient in the decryption process. In the proposed method, the storage space can be significantly decreased and the security of the system can be improved. The feasibility, security and robustness of the method are further analysed through computer simulations.

  6. Fast high-resolution MR imaging using the snapshot-FLASH MR sequence

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Henrich, D.; Duhmke, E.

    1990-01-01

    Snapshot, fast low-angle short (FLASH) MR imaging using an accelerated FLASH-MR sequence provides MR images with measuring times far below 1 second. The short TE of this sequence prevents susceptibility artifacts in gradient-echo imaging. In this paper variations of the sequence are shown that provide high resolution images with T1-weighted IR, T2-weighted SE, and chemical shift (CHESS) contrast sequences. METHODS AND MATERIALS: A whole-body 2-T system (Bruker-Medizintechnik) were used in combination with a 60-cm gradient system (providing gradient strength of 5 mT/m) to study healthy volunteers. The measuring time for a 256 x 256 image matrix was 800 msec. This sequence has been used in combination with T1-weighted IR, T2-weighted SE, and CHESS variations

  7. Schedule Optimization of Imaging Missions for Multiple Satellites and Ground Stations Using Genetic Algorithm

    Science.gov (United States)

    Lee, Junghyun; Kim, Heewon; Chung, Hyun; Kim, Haedong; Choi, Sujin; Jung, Okchul; Chung, Daewon; Ko, Kwanghee

    2018-04-01

    In this paper, we propose a method that uses a genetic algorithm for the dynamic schedule optimization of imaging missions for multiple satellites and ground systems. In particular, the visibility conflicts of communication and mission operation using satellite resources (electric power and onboard memory) are integrated in sequence. Resource consumption and restoration are considered in the optimization process. Image acquisition is an essential part of satellite missions and is performed via a series of subtasks such as command uplink, image capturing, image storing, and image downlink. An objective function for optimization is designed to maximize the usability by considering the following components: user-assigned priority, resource consumption, and image-acquisition time. For the simulation, a series of hypothetical imaging missions are allocated to a multi-satellite control system comprising five satellites and three ground stations having S- and X-band antennas. To demonstrate the performance of the proposed method, simulations are performed via three operation modes: general, commercial, and tactical.

  8. An objective method to optimize the MR sequence set for plaque classification in carotid vessel wall images using automated image segmentation.

    Directory of Open Access Journals (Sweden)

    Ronald van 't Klooster

    Full Text Available A typical MR imaging protocol to study the status of atherosclerosis in the carotid artery consists of the application of multiple MR sequences. Since scanner time is limited, a balance has to be reached between the duration of the applied MR protocol and the quantity and quality of the resulting images which are needed to assess the disease. In this study an objective method to optimize the MR sequence set for classification of soft plaque in vessel wall images of the carotid artery using automated image segmentation was developed. The automated method employs statistical pattern recognition techniques and was developed based on an extensive set of MR contrast weightings and corresponding manual segmentations of the vessel wall and soft plaque components, which were validated by histological sections. Evaluation of the results from nine contrast weightings showed the tradeoff between scan duration and automated image segmentation performance. For our dataset the best segmentation performance was achieved by selecting five contrast weightings. Similar performance was achieved with a set of three contrast weightings, which resulted in a reduction of scan time by more than 60%. The presented approach can help others to optimize MR imaging protocols by investigating the tradeoff between scan duration and automated image segmentation performance possibly leading to shorter scanning times and better image interpretation. This approach can potentially also be applied to other research fields focusing on different diseases and anatomical regions.

  9. Importance of multidetector CT imaging in multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Geyer, L.L.; Reiser, M.; Wirth, S.; Koerner, M.

    2014-01-01

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [de

  10. AUTOMATIC 3D MAPPING USING MULTIPLE UNCALIBRATED CLOSE RANGE IMAGES

    Directory of Open Access Journals (Sweden)

    M. Rafiei

    2013-09-01

    Full Text Available Automatic three-dimensions modeling of the real world is an important research topic in the geomatics and computer vision fields for many years. By development of commercial digital cameras and modern image processing techniques, close range photogrammetry is vastly utilized in many fields such as structure measurements, topographic surveying, architectural and archeological surveying, etc. A non-contact photogrammetry provides methods to determine 3D locations of objects from two-dimensional (2D images. Problem of estimating the locations of 3D points from multiple images, often involves simultaneously estimating both 3D geometry (structure and camera pose (motion, it is commonly known as structure from motion (SfM. In this research a step by step approach to generate the 3D point cloud of a scene is considered. After taking images with a camera, we should detect corresponding points in each two views. Here an efficient SIFT method is used for image matching for large baselines. After that, we must retrieve the camera motion and 3D position of the matched feature points up to a projective transformation (projective reconstruction. Lacking additional information on the camera or the scene makes the parallel lines to be unparalleled. The results of SfM computation are much more useful if a metric reconstruction is obtained. Therefor multiple views Euclidean reconstruction applied and discussed. To refine and achieve the precise 3D points we use more general and useful approach, namely bundle adjustment. At the end two real cases have been considered to reconstruct (an excavation and a tower.

  11. NMR multiple-echo phase-contrast blood flow imaging

    International Nuclear Information System (INIS)

    O'Donnell, M.

    1986-01-01

    A method is described for magnetic resonance imaging of fluid flow in a sample, comprising the steps of: (a) immersing the sample in a static magnetic field disposed in a first direction; (b) applying a first sequence of magnetic field gradients and radio-frequency signals to the sample to both define a slab, of the sample to be imaged, in a plane substantially orthogonal to a selected direction for which flow velocity is to be measured, and to obtain a plurality N of spin-echo response signals form that slab; (c) processing the plurality of first sequence spin-echo signals to obtain a complex value A/sub 1/(X,Y,Z) relating both the spin density rho'(X,Y,Z),... and the phase rotation phi(X,Y,Z), induced by the first sequence, for each of a selected number of sequential locations (X,Y,Z) in the sample slab; (d) applying a second sequence of magnetic field gradient and radio-frequency signals to both define the same sample slab as in step (b) and to obtain another plurality N of spin-echo response signals from that slab; (e) including a waveform in at least one of the magnetic field gradient and radio-frequency signals applied in step (d) for imparting to each of the spin-echo signal components from each slab location having a flowing material therein a phase rotation dependent upon the magnitude of the flow velocity therein in the selected direction; (f) processing the plurality of second sequence spin-echo signals to obtain a complex value A/sub 2/(X,Y,Z) relating the spin density rho'(X,Y,Z) and the imparted phase rotation of the sample material along the selected flow measurement direction for each of the sequential locations (X,Y,Z) in the sample slab; and (g) processing the complex values A/sub 1/(X,Y,Z) and A/sub 2/(X,Y,Z) for each sample location to obtain a differential phase-contrast value related to the velocity of the flowing material therein in the selected measurement direction

  12. The use of coded PCR primers enables high-throughput sequencing of multiple homolog amplification products by 454 parallel sequencing

    DEFF Research Database (Denmark)

    Binladen, Jonas; Gilbert, M Thomas P; Bollback, Jonathan P

    2007-01-01

    BACKGROUND: The invention of the Genome Sequence 20 DNA Sequencing System (454 parallel sequencing platform) has enabled the rapid and high-volume production of sequence data. Until now, however, individual emulsion PCR (emPCR) reactions and subsequent sequencing runs have been unable to combine...... primers that is dependent on the 5' nucleotide of the tag. In particular, primers 5' labelled with a cytosine are heavily overrepresented among the final sequences, while those 5' labelled with a thymine are strongly underrepresented. A weaker bias also exists with regards to the distribution...

  13. Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Bot, J.C.J.; Barkhof, F.; Lycklama a Nijeholt, G.J.; Bergers, E.; Castelijns, J.A.; Polman, C.H.; Ader, H.J.

    2000-01-01

    The current optimal imaging protocol in spinal cord MR imaging in patients with multiple sclerosis includes a long TR conventional spin-echo (CSE) sequence, requiring long acquisition times. Using short tau inversion recovery fast spin-echo (fast STIR) sequences both acquisition time can be shortened and sensitivity in the detection of multiple sclerosis (MS) abnormalities can be increased. This study compares both sequences for the potential to detect both focal and diffuse spinal abnormalities. Spinal cords of 5 volunteers and 20 MS patients were studied at 1.0 T. Magnetic resonance imaging included cardiac-gated sagittal dual-echo CSE and a cardiac-gated fast STIR sequence. Images were scored regarding number, size, and location of focal lesions, diffuse abnormalities and presence/hindrance of artifacts by two experienced radiologists. Examinations were scored as being definitely normal, indeterminate, or definitely abnormal. Interobserver agreement regarding focal lesions was higher for CSE (κ=0.67) than for fast STIR (κ=0.57) but did not differ significantly. Of all focal lesions scored in consensus, 47 % were scored on both sequences, 31 % were only detected by fast STIR, and 22 % only by dual-echo CSE (n. s.). Interobserver agreement for diffuse abnormalities was lower with fast STIR (κ=0.48) than dual-echo CSE (κ=0.65; n. s.). After consensus, fast STIR showed in 10 patients diffuse abnormalities and dual-echo CSE in 3. After consensus, in 19 of 20 patients dual-echo CSE scans were considered as definitely abnormal compared with 17 for fast STIR. The fast STIR sequence is a useful adjunct to dual-echo CSE in detecting focal abnormalities and is helpful in detecting diffuse MS abnormalities in the spinal cord. Due to the frequent occurrence of artifacts and the lower observer concordance, fast STIR cannot be used alone. (orig.)

  14. The role of Acinetobacter in the pathogenesis of multiple sclerosis examined by using Popper sequences.

    Science.gov (United States)

    Ebringer, Alan; Rashid, Taha; Wilson, Clyde

    2012-06-01

    Multiple sclerosis (MS) is an autoimmune neurological disorder. The role of 'Acinetobacter' has been examined using the method of Karl Popper and involves nine "Popper sequences". (1) The frequency of MS increases with latitudes in the Northern Hemisphere, and the reverse is found in the Southern Hemisphere. (2) Sinusitis is found frequently at colder latitudes. (3) Sinusitis occurs frequently in patients with MS. (4) Specific sequences of bovine myelin when injected into experimental animals will produce a neurological disorder resembling MS which is called "experimental allergic encephalomyelitis". (5) Computer analysis of myelin shows molecular mimicry with sequences found in Acinetobacter. (6) Antibodies to Acinetobacter bacteria are found in MS patients. (7) Acinetobacter bacteria are located on human skin and in the nasal sinuses. (8) IgA antibodies are preferentially elevated in the sera of MS patients, thereby suggesting the trigger microbe is acting across a mucosal surface probably located in the nasal sinuses. (9) Only Acinetobacter bacteria and no other microbes evoke statistically significant titres of antibodies in MS patients. These nine Popper sequences suggest that MS is most probably caused by infections with Acinetobacter bacteria in the nasal sinuses, and this could have therapeutic implications. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Pseudomalignant myositis ossificans involving multiple masticatory muscles: Imaging evaluation

    International Nuclear Information System (INIS)

    Kamalapur, Muralidhar G; Patil, Pritam B; Joshi, Shyamsundar; Shastri, Dinesh

    2014-01-01

    Myositis ossificans is a rare cause of trismus. We present a case of pseudomalignant myositis ossificans involving medial pterygoid, lateral pterygoid, and temporalis muscles. Patient presented with gross limitation in mouth opening. There was no history of trauma. Computed tomography (CT) images revealed a bone density mass located in the region of medial and lateral pterygoid muscles on the right and temporalis muscle on the left. Magnetic resonance imaging (MRI) showed similar findings. Radiological diagnosis was pseudomalignant myositis ossificans. The masses were resected and histopathologic examination confirmed the above diagnosis. This report describes the characteristic CT and MRI features. The unique feature of this case is the absence of history of trauma with involvement of multiple masticatory muscles, which, to the best of our knowledge, has not been reported before

  16. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Energy Technology Data Exchange (ETDEWEB)

    Patzig, M.; Brueckmann, H.; Fesl, G. [Muenchen Univ. (Germany). Dept. of Neuroradiology; Burke, M. [GE Healthcare, Solingen (Germany)

    2014-05-15

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  17. Clinical and imaging assessment of cognitive dysfunction in multiple sclerosis

    DEFF Research Database (Denmark)

    Rocca, Maria A; Amato, Maria P; De Stefano, Nicola

    2015-01-01

    In patients with multiple sclerosis (MS), grey matter damage is widespread and might underlie many of the clinical symptoms, especially cognitive impairment. This relation between grey matter damage and cognitive impairment has been lent support by findings from clinical and MRI studies. However...... that causes clinical symptoms to trigger. Findings on cortical reorganisation support the contribution of brain plasticity and cognitive reserve in limiting cognitive deficits. The development of clinical and imaging biomarkers that can monitor disease development and treatment response is crucial to allow...

  18. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  19. Video Multiple Watermarking Technique Based on Image Interlacing Using DWT

    Directory of Open Access Journals (Sweden)

    Mohamed M. Ibrahim

    2014-01-01

    Full Text Available Digital watermarking is one of the important techniques to secure digital media files in the domains of data authentication and copyright protection. In the nonblind watermarking systems, the need of the original host file in the watermark recovery operation makes an overhead over the system resources, doubles memory capacity, and doubles communications bandwidth. In this paper, a robust video multiple watermarking technique is proposed to solve this problem. This technique is based on image interlacing. In this technique, three-level discrete wavelet transform (DWT is used as a watermark embedding/extracting domain, Arnold transform is used as a watermark encryption/decryption method, and different types of media (gray image, color image, and video are used as watermarks. The robustness of this technique is tested by applying different types of attacks such as: geometric, noising, format-compression, and image-processing attacks. The simulation results show the effectiveness and good performance of the proposed technique in saving system resources, memory capacity, and communications bandwidth.

  20. Video multiple watermarking technique based on image interlacing using DWT.

    Science.gov (United States)

    Ibrahim, Mohamed M; Abdel Kader, Neamat S; Zorkany, M

    2014-01-01

    Digital watermarking is one of the important techniques to secure digital media files in the domains of data authentication and copyright protection. In the nonblind watermarking systems, the need of the original host file in the watermark recovery operation makes an overhead over the system resources, doubles memory capacity, and doubles communications bandwidth. In this paper, a robust video multiple watermarking technique is proposed to solve this problem. This technique is based on image interlacing. In this technique, three-level discrete wavelet transform (DWT) is used as a watermark embedding/extracting domain, Arnold transform is used as a watermark encryption/decryption method, and different types of media (gray image, color image, and video) are used as watermarks. The robustness of this technique is tested by applying different types of attacks such as: geometric, noising, format-compression, and image-processing attacks. The simulation results show the effectiveness and good performance of the proposed technique in saving system resources, memory capacity, and communications bandwidth.

  1. Multiple imaging procedures including MRI for the bladder cancer

    International Nuclear Information System (INIS)

    Mikata, Noriharu; Suzuki, Makoto; Takeuchi, Takumi; Kunisawa, Yositaka; Fukutani, Keiko; Kawabe, Kazuki

    1986-01-01

    Endoscopic photography, double contrast cystography, transurethral echography, X-ray CT scan, and MRI (magnetic resonance imaging) were utilized for the staging diagnosis of the four patients with carcinoma of the bladder. In the first case, a 70-year-old man, since all of the five imaging procedures suggested a superficial and pedunculated tumor, his bladder cancer was considered T1. The classification of stage T3 carcinoma was made for the second 86-year-old male. Because all of his imaging examinations showed a tumor infiltrating deep muscle and penetrating the bladder wall. The third case was a 36-year-old male. His clinical stage was diagnosed as T2 or T3a by cystophotography, double contrast cystogram, ultrasonography, and X-ray CT scan. However, MRI showed only thickened bladder wall and the infiltrating tumor could not be distinguished from the hypertrophic wall. The last patient, a 85-year-old female, had a smaller Ta cancer. Her double contrast cystography revealed the small tumor at the lateral bladder wall. But, the tumor could not be detected by transaxial, sagittal and coronal scans. Multiple imaging procedures combining MRI and staging diagnosis of the bladder carcinoma were discussed. (author)

  2. Enhanced spatio-temporal alignment of plantar pressure image sequences using B-splines.

    Science.gov (United States)

    Oliveira, Francisco P M; Tavares, João Manuel R S

    2013-03-01

    This article presents an enhanced methodology to align plantar pressure image sequences simultaneously in time and space. The temporal alignment of the sequences is accomplished using B-splines in the time modeling, and the spatial alignment can be attained using several geometric transformation models. The methodology was tested on a dataset of 156 real plantar pressure image sequences (3 sequences for each foot of the 26 subjects) that was acquired using a common commercial plate during barefoot walking. In the alignment of image sequences that were synthetically deformed both in time and space, an outstanding accuracy was achieved with the cubic B-splines. This accuracy was significantly better (p align real image sequences with unknown transformation involved, the alignment based on cubic B-splines also achieved superior results than our previous methodology (p alignment on the dynamic center of pressure (COP) displacement was also assessed by computing the intraclass correlation coefficients (ICC) before and after the temporal alignment of the three image sequence trials of each foot of the associated subject at six time instants. The results showed that, generally, the ICCs related to the medio-lateral COP displacement were greater when the sequences were temporally aligned than the ICCs of the original sequences. Based on the experimental findings, one can conclude that the cubic B-splines are a remarkable solution for the temporal alignment of plantar pressure image sequences. These findings also show that the temporal alignment can increase the consistency of the COP displacement on related acquired plantar pressure image sequences.

  3. [Exome sequencing revealed Allan-Herndon-Dudley syndrome underlying multiple disabilities].

    Science.gov (United States)

    Arvio, Maria; Philips, Anju K; Ahvenainen, Minna; Somer, Mirja; Kalscheuer, Vera; Järvelä, Irma

    2014-01-01

    Normal function of the thyroid gland is the cornerstone of a child's mental development and physical growth. We describe a Finnish family, in which the diagnosis of three brothers became clear after investigations that lasted for more than 30 years. Two of the sons have already died. DNA analysis of the third one, a 16-year-old boy, revealed in exome sequencing of the complete X chromosome a mutation in the SLC16A2 gene, i.e. MCT8, coding for a thyroid hormone transport protein. Allan-Herndon-Dudley syndrome was thus shown to be the cause of multiple disabilities.

  4. Observation of Multiple Volume Reflection of Ultrarelativistic Protons by a Sequence of Several Bent Silicon Crystals

    CERN Document Server

    Scandale, Walter; Baricordi, S; Dalpiaz, P; Fiorini, M; Guidi, V; Mazzolari, A; Della Mea, G; Milan, R; Ambrosi, G; Zuccon, P; Bertucci, B; Bürger, W; Duranti, M; Cavoto, G; Santacesaria, R; Valente, P; Luci, C; Iacoangeli, F; Vallazza, E; Afonin, A G; Chesnokov, Yu A; Kotov, V I; Maisheev, V A; Yazynin, I A; Kovalenko, A D; Taratin, A M; Denisov, A S; Gavrikov, Y A; Ivanov, Yu M; Lapina, L P; Malyarenko, L G; Skorogobogatov, V V; Suvorov, V M; Vavilov, S A; Bolognini, D; Hasan, S; Mozzanica, A; Prest, M

    2009-01-01

    The interactions of 400 GeV protons with different sequences of bent silicon crystals have been investigated at the H8 beam line of the CERN Super Proton Synchrotron. The multiple volume reflection of the proton beam has been studied in detail on a five-crystal reflector measuring an angular beam deflection =52.96±0.14 µrad. The efficiency was found larger than 80% for an angular acceptance at the reflector entrance of 70 µrad, with a maximal efficiency value of =0.90±0.01±0.03.

  5. Real-time UAV trajectory generation using feature points matching between video image sequences

    Science.gov (United States)

    Byun, Younggi; Song, Jeongheon; Han, Dongyeob

    2017-09-01

    Unmanned aerial vehicles (UAVs), equipped with navigation systems and video capability, are currently being deployed for intelligence, reconnaissance and surveillance mission. In this paper, we present a systematic approach for the generation of UAV trajectory using a video image matching system based on SURF (Speeded up Robust Feature) and Preemptive RANSAC (Random Sample Consensus). Video image matching to find matching points is one of the most important steps for the accurate generation of UAV trajectory (sequence of poses in 3D space). We used the SURF algorithm to find the matching points between video image sequences, and removed mismatching by using the Preemptive RANSAC which divides all matching points to outliers and inliers. The inliers are only used to determine the epipolar geometry for estimating the relative pose (rotation and translation) between image sequences. Experimental results from simulated video image sequences showed that our approach has a good potential to be applied to the automatic geo-localization of the UAVs system

  6. Analysis of Multiple Genomic Sequence Alignments: A Web Resource, Online Tools, and Lessons Learned From Analysis of Mammalian SCL Loci

    Science.gov (United States)

    Chapman, Michael A.; Donaldson, Ian J.; Gilbert, James; Grafham, Darren; Rogers, Jane; Green, Anthony R.; Göttgens, Berthold

    2004-01-01

    Comparative analysis of genomic sequences is becoming a standard technique for studying gene regulation. However, only a limited number of tools are currently available for the analysis of multiple genomic sequences. An extensive data set for the testing and training of such tools is provided by the SCL gene locus. Here we have expanded the data set to eight vertebrate species by sequencing the dog SCL locus and by annotating the dog and rat SCL loci. To provide a resource for the bioinformatics community, all SCL sequences and functional annotations, comprising a collation of the extensive experimental evidence pertaining to SCL regulation, have been made available via a Web server. A Web interface to new tools specifically designed for the display and analysis of multiple sequence alignments was also implemented. The unique SCL data set and new sequence comparison tools allowed us to perform a rigorous examination of the true benefits of multiple sequence comparisons. We demonstrate that multiple sequence alignments are, overall, superior to pairwise alignments for identification of mammalian regulatory regions. In the search for individual transcription factor binding sites, multiple alignments markedly increase the signal-to-noise ratio compared to pairwise alignments. PMID:14718377

  7. MR imaging of the temporomandibular joint. Part 2. Effect of flip angle on MR imaging with FLASH sequence

    International Nuclear Information System (INIS)

    Sakamoto, Maya; Sasano, Takashi; Higano, Shuichi; Takahashi, Shoki; Kurihara, Noriko

    1998-01-01

    In our previous study on MR imaging of the temporomandibular joint (TMJ), fast low angle shot (FLASH) showed the highest image contrast between disc and surrounding TMJ tissues compared with those of 4 other sequences (i,e., fast imaging with steady precession (FISP), conventional T1-weighted spin echo (SE) and fast spin echo (FSE, TR/TE/ETL: 1100/12/3, 3000/15/7)). Furthermore, FLASH also received a high score on visual evaluation including the position and contour of the disc, and the border between the disc and surrounding tissues. Therefore, we concluded that FLASH was the most suitable sequence for evaluating the TMJ disc. However, the image contrast and signal intensity on MR imaging with gradient echo pulse sequence are affected by flip angle. Consequently, in this report, to find the most suitable flip angle for MR scanning of the TMJ using a FLASH sequence (TR/TE: 450/11), ten TMJs of 5 volunteers were experimentally imaged with various flip angles from 10 degrees to 70 degrees at an interval of 10 degrees between 10 to 70. The image contrast and contrast-to-noise ratio (CNR) between the disc and surrounding tissues were compared. In addition, signal-to-noise ratio (SNR) of phantoms was also calculated using the same imaging parameters. Visual evaluation including position and contour of the disc, and the border between the disc and surrounding tissues, was also performed by 4 radiologists. As the flip angle increased, imaging contrast decreased while SNR increased. Images with flip angles between 30 and 60 degrees demonstrated high CNR. On visual evaluation, images using flip angles between 30 and 50 degrees received high scores. In conclusion, FLASH sequence with a flip angle between 30 and 50 degrees was considered most suitable for evaluating the TMJ disc based on the results of visual assessment and analysis of three major components of image diagnostic quality: image contrast, CNR and SNR. (author)

  8. Study on multiple-hops performance of MOOC sequences-based optical labels for OPS networks

    Science.gov (United States)

    Zhang, Chongfu; Qiu, Kun; Ma, Chunli

    2009-11-01

    In this paper, we utilize a new study method that is under independent case of multiple optical orthogonal codes to derive the probability function of MOOCS-OPS networks, discuss the performance characteristics for a variety of parameters, and compare some characteristics of the system employed by single optical orthogonal code or multiple optical orthogonal codes sequences-based optical labels. The performance of the system is also calculated, and our results verify that the method is effective. Additionally it is found that performance of MOOCS-OPS networks would, negatively, be worsened, compared with single optical orthogonal code-based optical label for optical packet switching (SOOC-OPS); however, MOOCS-OPS networks can greatly enlarge the scalability of optical packet switching networks.

  9. GEOPOSITIONING PRECISION ANALYSIS OF MULTIPLE IMAGE TRIANGULATION USING LRO NAC LUNAR IMAGES

    Directory of Open Access Journals (Sweden)

    K. Di

    2016-06-01

    Full Text Available This paper presents an empirical analysis of the geopositioning precision of multiple image triangulation using Lunar Reconnaissance Orbiter Camera (LROC Narrow Angle Camera (NAC images at the Chang’e-3(CE-3 landing site. Nine LROC NAC images are selected for comparative analysis of geopositioning precision. Rigorous sensor models of the images are established based on collinearity equations with interior and exterior orientation elements retrieved from the corresponding SPICE kernels. Rational polynomial coefficients (RPCs of each image are derived by least squares fitting using vast number of virtual control points generated according to rigorous sensor models. Experiments of different combinations of images are performed for comparisons. The results demonstrate that the plane coordinates can achieve a precision of 0.54 m to 2.54 m, with a height precision of 0.71 m to 8.16 m when only two images are used for three-dimensional triangulation. There is a general trend that the geopositioning precision, especially the height precision, is improved with the convergent angle of the two images increasing from several degrees to about 50°. However, the image matching precision should also be taken into consideration when choosing image pairs for triangulation. The precisions of using all the 9 images are 0.60 m, 0.50 m, 1.23 m in along-track, cross-track, and height directions, which are better than most combinations of two or more images. However, triangulation with selected fewer images could produce better precision than that using all the images.

  10. Multiple amino acid sequence alignment nitrogenase component 1: insights into phylogenetics and structure-function relationships.

    Directory of Open Access Journals (Sweden)

    James B Howard

    Full Text Available Amino acid residues critical for a protein's structure-function are retained by natural selection and these residues are identified by the level of variance in co-aligned homologous protein sequences. The relevant residues in the nitrogen fixation Component 1 α- and β-subunits were identified by the alignment of 95 protein sequences. Proteins were included from species encompassing multiple microbial phyla and diverse ecological niches as well as the nitrogen fixation genotypes, anf, nif, and vnf, which encode proteins associated with cofactors differing at one metal site. After adjusting for differences in sequence length, insertions, and deletions, the remaining >85% of the sequence co-aligned the subunits from the three genotypes. Six Groups, designated Anf, Vnf , and Nif I-IV, were assigned based upon genetic origin, sequence adjustments, and conserved residues. Both subunits subdivided into the same groups. Invariant and single variant residues were identified and were defined as "core" for nitrogenase function. Three species in Group Nif-III, Candidatus Desulforudis audaxviator, Desulfotomaculum kuznetsovii, and Thermodesulfatator indicus, were found to have a seleno-cysteine that replaces one cysteinyl ligand of the 8Fe:7S, P-cluster. Subsets of invariant residues, limited to individual groups, were identified; these unique residues help identify the gene of origin (anf, nif, or vnf yet should not be considered diagnostic of the metal content of associated cofactors. Fourteen of the 19 residues that compose the cofactor pocket are invariant or single variant; the other five residues are highly variable but do not correlate with the putative metal content of the cofactor. The variable residues are clustered on one side of the cofactor, away from other functional centers in the three dimensional structure. Many of the invariant and single variant residues were not previously recognized as potentially critical and their identification

  11. Whole exome sequencing reveals concomitant mutations of multiple FA genes in individual Fanconi anemia patients.

    Science.gov (United States)

    Chang, Lixian; Yuan, Weiping; Zeng, Huimin; Zhou, Quanquan; Wei, Wei; Zhou, Jianfeng; Li, Miaomiao; Wang, Xiaomin; Xu, Mingjiang; Yang, Fengchun; Yang, Yungui; Cheng, Tao; Zhu, Xiaofan

    2014-05-15

    Fanconi anemia (FA) is a rare inherited genetic syndrome with highly variable clinical manifestations. Fifteen genetic subtypes of FA have been identified. Traditional complementation tests for grouping studies have been used generally in FA patients and in stepwise methods to identify the FA type, which can result in incomplete genetic information from FA patients. We diagnosed five pediatric patients with FA based on clinical manifestations, and we performed exome sequencing of peripheral blood specimens from these patients and their family members. The related sequencing data were then analyzed by bioinformatics, and the FANC gene mutations identified by exome sequencing were confirmed by PCR re-sequencing. Homozygous and compound heterozygous mutations of FANC genes were identified in all of the patients. The FA subtypes of the patients included FANCA, FANCM and FANCD2. Interestingly, four FA patients harbored multiple mutations in at least two FA genes, and some of these mutations have not been previously reported. These patients' clinical manifestations were vastly different from each other, as were their treatment responses to androstanazol and prednisone. This finding suggests that heterozygous mutation(s) in FA genes could also have diverse biological and/or pathophysiological effects on FA patients or FA gene carriers. Interestingly, we were not able to identify de novo mutations in the genes implicated in DNA repair pathways when the sequencing data of patients were compared with those of their parents. Our results indicate that Chinese FA patients and carriers might have higher and more complex mutation rates in FANC genes than have been conventionally recognized. Testing of the fifteen FANC genes in FA patients and their family members should be a regular clinical practice to determine the optimal care for the individual patient, to counsel the family and to obtain a better understanding of FA pathophysiology.

  12. MR imaging of articular cartilage in the ankle: comparison of available imaging sequences and methods of measurement in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Tan, T.C.F. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)]|[Department of Radiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan (Taiwan, Province of China); Wilcox, D.M. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Frank, L. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Shih, C. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)]|[Department of Radiology, Veterans General Hospital-Taipei (Taiwan, Province of China); Trudell, D.J. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Sartoris, D.J. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States); Resnick, D. [Department of Radiology, Veterans Administrative Medical Center, San Diego, CA (United States)]|[University of California Medical Center, San Diego, CA (United States)

    1996-11-01

    Objective. To assess hyaline cartilage of cadaveric ankles using different magnetic resonance (MR) imaging techniques and various methods of measurement. Design and patients. Cartilage thicknesses of the talus and tibia were measured in ten cadaveric ankles by naked eye and by digitized image analysis from MR images of fat-suppressed T1-weighted gradient recalled (FS-SPGR), sequences and pulsed transfer saturation sequences with (FS-STS) and without fat-suppression (STS); these measurements were compared with those derived from direct inspection of cadaveric sections. The accuracy and precision errors were evaluated statistically for each imaging technique as well as measuring method. Contrast-to-noise ratios of cartilage versus joint fluid and marrow were compared for each of the imaging sequences. Results. Statistically, measurements from FS-SPGR images were associated with the smallest estimation error. Precision error of measurements derived from digitized image analysis was found to be smaller than that derived from naked eye measurements. Cartilage thickness measurements in images from STS and FS-STS sequences revealed larger errors in both accuracy and precision. Interobserver variance was larger in naked eye assessment of the cartilage. Contrast-to-noise ratio of cartilage versus joint fluid and marrow was higher with FS-SPGR than with FS-STS or STS sequences. Conclusion. Of the sequences and measurement techniques studied, the FS-SPGR sequence combined with the use of digitized image analysis provides the most accurate method for the assessment of ankle hyaline cartilage. (orig.). With 3 figs., 2 tabs.

  13. MR imaging of articular cartilage in the ankle: comparison of available imaging sequences and methods of measurement in cadavers

    International Nuclear Information System (INIS)

    Tan, T.C.F.; Wilcox, D.M.; Frank, L.; Shih, C.; Trudell, D.J.; Sartoris, D.J.; Resnick, D.

    1996-01-01

    Objective. To assess hyaline cartilage of cadaveric ankles using different magnetic resonance (MR) imaging techniques and various methods of measurement. Design and patients. Cartilage thicknesses of the talus and tibia were measured in ten cadaveric ankles by naked eye and by digitized image analysis from MR images of fat-suppressed T1-weighted gradient recalled (FS-SPGR), sequences and pulsed transfer saturation sequences with (FS-STS) and without fat-suppression (STS); these measurements were compared with those derived from direct inspection of cadaveric sections. The accuracy and precision errors were evaluated statistically for each imaging technique as well as measuring method. Contrast-to-noise ratios of cartilage versus joint fluid and marrow were compared for each of the imaging sequences. Results. Statistically, measurements from FS-SPGR images were associated with the smallest estimation error. Precision error of measurements derived from digitized image analysis was found to be smaller than that derived from naked eye measurements. Cartilage thickness measurements in images from STS and FS-STS sequences revealed larger errors in both accuracy and precision. Interobserver variance was larger in naked eye assessment of the cartilage. Contrast-to-noise ratio of cartilage versus joint fluid and marrow was higher with FS-SPGR than with FS-STS or STS sequences. Conclusion. Of the sequences and measurement techniques studied, the FS-SPGR sequence combined with the use of digitized image analysis provides the most accurate method for the assessment of ankle hyaline cartilage. (orig.). With 3 figs., 2 tabs

  14. Multiple speckle illumination for optical-resolution photoacoustic imaging

    Science.gov (United States)

    Poisson, Florian; Stasio, Nicolino; Moser, Christophe; Psaltis, Demetri; Bossy, Emmanuel

    2017-03-01

    Optical-resolution photoacoustic microscopy offers exquisite and specific contrast to optical absorption. Conventional approaches generally involves raster scanning a focused spot over the sample. Here, we demonstrate that a full-field illumination approach with multiple speckle illumination can also provide diffraction-limited optical-resolution photoacoustic images. Two different proof-of-concepts are demonstrated with micro-structured test samples. The first approach follows the principle of correlation/ghost imaging,1, 2 and is based on cross-correlating photoacoustic signals under multiple speckle illumination with known speckle patterns measured during a calibration step. The second approach is a speckle scanning microscopy technique, which adapts the technique proposed in fluorescence microscopy by Bertolotti and al.:3 in our work, spatially unresolved photoacoustic measurements are performed for various translations of unknown speckle patterns. A phase-retrieval algorithm is used to reconstruct the object from the knowledge of the modulus of its Fourier Transform yielded by the measurements. Because speckle patterns naturally appear in many various situations, including propagation through biological tissue or multi-mode fibers (for which focusing light is either very demanding if not impossible), speckle-illumination-based photoacoustic microscopy provides a powerful framework for the development of novel reconstruction approaches, well-suited to compressed sensing approaches.2

  15. “Hot cross bun” sign in multiple system atrophy with predominant cerebellar ataxia: A comparison between proton density-weighted imaging and T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kasahara, Seiko, E-mail: nuun077@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Miki, Yukio, E-mail: yukio.miki@med.osaka-cu.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545–8585 (Japan); Kanagaki, Mitsunori, E-mail: mitsuk@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Kondo, Takayuki, E-mail: kondotak@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Yamamoto, Akira, E-mail: yakira@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Morimoto, Emiko, E-mail: foresta@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Ito, Hidefumi, E-mail: itohid@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Takahashi, Ryosuke, E-mail: ryosuket@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); and others

    2012-10-15

    Objective: To investigate whether proton density-weighted imaging can detect the “hot cross bun” sign in the pons in multiple system atrophy with predominant cerebellar ataxia significantly better than T2-weighted imaging at 3 T. Methods: Sixteen consecutive patients with multiple system atrophy with predominant cerebellar ataxia according to the Consensus Criteria were reviewed. Axial unenhanced proton density-weighted imaging and T2-weighted imaging were obtained using a dual-echo fast spin-echo sequence at 3 T. Two neuroradiologists independently evaluated visualisation of the abnormal pontine signal using a 4-point visual grade from Grade 0 (no “hot cross bun” sign) to Grade 3 (prominent “hot cross bun” sign on two or more sequential slices). Differences in grade between proton density-weighted imaging and T2-weighted imaging were statistically analysed using the Wilcoxon signed-rank test. Results: In 11 patients (69%), a higher grade was given for proton density-weighted imaging than T2-weighted imaging. In 1 patient (6%), grades were the same (Grade 3) on both images. In the remaining 4 patients (25%), signal abnormalities were not detected on either image (Grade 0). The “hot cross bun” sign was thus observed significantly better on proton density-weighted imaging than on T2-weighted imaging (P = 0.001). Conclusions: The “hot cross bun” sign considered diagnostic for multiple system atrophy with predominant cerebellar ataxia is significantly better visualised on proton density-weighted imaging than on T2-weighted imaging at 3 T.

  16. SATCHMO-JS: a webserver for simultaneous protein multiple sequence alignment and phylogenetic tree construction.

    Science.gov (United States)

    Hagopian, Raffi; Davidson, John R; Datta, Ruchira S; Samad, Bushra; Jarvis, Glen R; Sjölander, Kimmen

    2010-07-01

    We present the jump-start simultaneous alignment and tree construction using hidden Markov models (SATCHMO-JS) web server for simultaneous estimation of protein multiple sequence alignments (MSAs) and phylogenetic trees. The server takes as input a set of sequences in FASTA format, and outputs a phylogenetic tree and MSA; these can be viewed online or downloaded from the website. SATCHMO-JS is an extension of the SATCHMO algorithm, and employs a divide-and-conquer strategy to jump-start SATCHMO at a higher point in the phylogenetic tree, reducing the computational complexity of the progressive all-versus-all HMM-HMM scoring and alignment. Results on a benchmark dataset of 983 structurally aligned pairs from the PREFAB benchmark dataset show that SATCHMO-JS provides a statistically significant improvement in alignment accuracy over MUSCLE, Multiple Alignment using Fast Fourier Transform (MAFFT), ClustalW and the original SATCHMO algorithm. The SATCHMO-JS webserver is available at http://phylogenomics.berkeley.edu/satchmo-js. The datasets used in these experiments are available for download at http://phylogenomics.berkeley.edu/satchmo-js/supplementary/.

  17. Maximum-Likelihood Sequence Detection of Multiple Antenna Systems over Dispersive Channels via Sphere Decoding

    Directory of Open Access Journals (Sweden)

    Hassibi Babak

    2002-01-01

    Full Text Available Multiple antenna systems are capable of providing high data rate transmissions over wireless channels. When the channels are dispersive, the signal at each receive antenna is a combination of both the current and past symbols sent from all transmit antennas corrupted by noise. The optimal receiver is a maximum-likelihood sequence detector and is often considered to be practically infeasible due to high computational complexity (exponential in number of antennas and channel memory. Therefore, in practice, one often settles for a less complex suboptimal receiver structure, typically with an equalizer meant to suppress both the intersymbol and interuser interference, followed by the decoder. We propose a sphere decoding for the sequence detection in multiple antenna communication systems over dispersive channels. The sphere decoding provides the maximum-likelihood estimate with computational complexity comparable to the standard space-time decision-feedback equalizing (DFE algorithms. The performance and complexity of the sphere decoding are compared with the DFE algorithm by means of simulations.

  18. On-board processing of video image sequences

    DEFF Research Database (Denmark)

    Andersen, Jakob Dahl; Chanrion, Olivier Arnaud; Forchhammer, Søren

    2008-01-01

    and evaluated. On-board there are six video cameras each capturing images of 1024times1024 pixels of 12 bpp at a frame rate of 15 fps, thus totalling 1080 Mbits/s. In comparison the average downlink data rate for these images is projected to be 50 kbit/s. This calls for efficient on-board processing to select...

  19. Clinical evaluation of FMPSPGR sequence of the brain MR imaging

    International Nuclear Information System (INIS)

    Takahashi, Mitsuyuki; Hasegawa, Makoto; Mori, Naohiko; Yamanoguchi, Minoru; Matsubara, Tadashi

    1998-01-01

    In order to apply the FMPSPGR (fast multi planar spoiled GRASS) method to diagnose brain diseases, authors obtained the optimal condition for imaging by the phantom experiments and examined the clinical usefulness. Six kinds of the phantom, which were 4 of diluted Gd solution with different concentrations, olive oil and physiological saline solution were used. From the phantom experiments, TR/TE/FR=300/3.3/90 degrees was the optimal condition. The evaluation of the clinical images was performed on the same section by the ST method and the FMPSPGR method. Fifteen patients (9 men and 6 women, aged from 17 to 80 years) suspected of brain diseases were examined, including 8 of cerebral infarction, 1 of pontine infarction, 1 of brain contusion, 1 of intracerebral bleeding and 4 of brain tumors. Four cases of brain tumor were evaluated on the contrast imaging and the others were on the plain imaging. In the plain imaging, the FMPSPGR method was better than the SE method on the low signal region in the T1 weighted imaging. Furthermore, in the contrast imaging, it could give more clear images of the lesion in anterior cranial pit by suppressing artifacts of blood flow. The present results indicate that the FMPSPGR method is useful to diagnose brain diseases. (K.H.)

  20. Image registration based on virtual frame sequence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.; Ng, W.S. [Nanyang Technological University, Computer Integrated Medical Intervention Laboratory, School of Mechanical and Aerospace Engineering, Singapore (Singapore); Shi, D. (Nanyang Technological University, School of Computer Engineering, Singapore, Singpore); Wee, S.B. [Tan Tock Seng Hospital, Department of General Surgery, Singapore (Singapore)

    2007-08-15

    This paper is to propose a new framework for medical image registration with large nonrigid deformations, which still remains one of the biggest challenges for image fusion and further analysis in many medical applications. Registration problem is formulated as to recover a deformation process with the known initial state and final state. To deal with large nonlinear deformations, virtual frames are proposed to be inserted to model the deformation process. A time parameter is introduced and the deformation between consecutive frames is described with a linear affine transformation. Experiments are conducted with simple geometric deformation as well as complex deformations presented in MRI and ultrasound images. All the deformations are characterized with nonlinearity. The positive results demonstrated the effectiveness of this algorithm. The framework proposed in this paper is feasible to register medical images with large nonlinear deformations and is especially useful for sequential images. (orig.)

  1. An integrated multiple capillary array electrophoresis system for high-throughput DNA sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Lu, X.

    1998-03-27

    A capillary array electrophoresis system was chosen to perform DNA sequencing because of several advantages such as rapid heat dissipation, multiplexing capabilities, gel matrix filling simplicity, and the mature nature of the associated manufacturing technologies. There are two major concerns for the multiple capillary systems. One concern is inter-capillary cross-talk, and the other concern is excitation and detection efficiency. Cross-talk is eliminated through proper optical coupling, good focusing and immersing capillary array into index matching fluid. A side-entry excitation scheme with orthogonal detection was established for large capillary array. Two 100 capillary array formats were used for DNA sequencing. One format is cylindrical capillary with 150 {micro}m o.d., 75 {micro}m i.d and the other format is square capillary with 300 {micro}m out edge and 75 {micro}m inner edge. This project is focused on the development of excitation and detection of DNA as well as performing DNA sequencing. The DNA injection schemes are discussed for the cases of single and bundled capillaries. An individual sampling device was designed. The base-calling was performed for a capillary from the capillary array with the accuracy of 98%.

  2. SATe-II: very fast and accurate simultaneous estimation of multiple sequence alignments and phylogenetic trees.

    Science.gov (United States)

    Liu, Kevin; Warnow, Tandy J; Holder, Mark T; Nelesen, Serita M; Yu, Jiaye; Stamatakis, Alexandros P; Linder, C Randal

    2012-01-01

    Highly accurate estimation of phylogenetic trees for large data sets is difficult, in part because multiple sequence alignments must be accurate for phylogeny estimation methods to be accurate. Coestimation of alignments and trees has been attempted but currently only SATé estimates reasonably accurate trees and alignments for large data sets in practical time frames (Liu K., Raghavan S., Nelesen S., Linder C.R., Warnow T. 2009b. Rapid and accurate large-scale coestimation of sequence alignments and phylogenetic trees. Science. 324:1561-1564). Here, we present a modification to the original SATé algorithm that improves upon SATé (which we now call SATé-I) in terms of speed and of phylogenetic and alignment accuracy. SATé-II uses a different divide-and-conquer strategy than SATé-I and so produces smaller more closely related subsets than SATé-I; as a result, SATé-II produces more accurate alignments and trees, can analyze larger data sets, and runs more efficiently than SATé-I. Generally, SATé is a metamethod that takes an existing multiple sequence alignment method as an input parameter and boosts the quality of that alignment method. SATé-II-boosted alignment methods are significantly more accurate than their unboosted versions, and trees based upon these improved alignments are more accurate than trees based upon the original alignments. Because SATé-I used maximum likelihood (ML) methods that treat gaps as missing data to estimate trees and because we found a correlation between the quality of tree/alignment pairs and ML scores, we explored the degree to which SATé's performance depends on using ML with gaps treated as missing data to determine the best tree/alignment pair. We present two lines of evidence that using ML with gaps treated as missing data to optimize the alignment and tree produces very poor results. First, we show that the optimization problem where a set of unaligned DNA sequences is given and the output is the tree and alignment of

  3. Phylo-mLogo: an interactive and hierarchical multiple-logo visualization tool for alignment of many sequences

    Directory of Open Access Journals (Sweden)

    Lee DT

    2007-02-01

    Full Text Available Abstract Background When aligning several hundreds or thousands of sequences, such as epidemic virus sequences or homologous/orthologous sequences of some big gene families, to reconstruct the epidemiological history or their phylogenies, how to analyze and visualize the alignment results of many sequences has become a new challenge for computational biologists. Although there are several tools available for visualization of very long sequence alignments, few of them are applicable to the alignments of many sequences. Results A multiple-logo alignment visualization tool, called Phylo-mLogo, is presented in this paper. Phylo-mLogo calculates the variabilities and homogeneities of alignment sequences by base frequencies or entropies. Different from the traditional representations of sequence logos, Phylo-mLogo not only displays the global logo patterns of the whole alignment of multiple sequences, but also demonstrates their local homologous logos for each clade hierarchically. In addition, Phylo-mLogo also allows the user to focus only on the analysis of some important, structurally or functionally constrained sites in the alignment selected by the user or by built-in automatic calculation. Conclusion With Phylo-mLogo, the user can symbolically and hierarchically visualize hundreds of aligned sequences simultaneously and easily check the changes of their amino acid sites when analyzing many homologous/orthologous or influenza virus sequences. More information of Phylo-mLogo can be found at URL http://biocomp.iis.sinica.edu.tw/phylomlogo.

  4. MR imaging of the orbit and eye using inversion recovery sequences

    International Nuclear Information System (INIS)

    Smith, F.W.; Parekh, S.; Forrester, J.; Redpath, T.W.

    1986-01-01

    Most centers performing MR imaging use spin-echo sequences to produce images; however, there are many advantages to using short TI inversion-recovery sequences for examination of the orbits. By selecting a TI similar to the relaxation time of any structure, the signal from this can be suppressed, thereby enhancing the signal from other structures. Using a sequence of TR = 1,000 msec and TI of less than 200 msec, the signal from fat is suppressed, improving image quality adjacent to the surface coil and providing better contrast between orbital structures and fat. The use of this short TI sequence for the examination of the eye in patients with opaque lenses is an accurate method of diagnosis since the sequence enhances the signal from both long T1 and T2 lesions. Eighty-five patients with orbital or ocular pathology have been studied, and the results demonstrate the usefulness of this technique for diagnosis

  5. CT Image Sequence Restoration Based on Sparse and Low-Rank Decomposition

    Science.gov (United States)

    Gou, Shuiping; Wang, Yueyue; Wang, Zhilong; Peng, Yong; Zhang, Xiaopeng; Jiao, Licheng; Wu, Jianshe

    2013-01-01

    Blurry organ boundaries and soft tissue structures present a major challenge in biomedical image restoration. In this paper, we propose a low-rank decomposition-based method for computed tomography (CT) image sequence restoration, where the CT image sequence is decomposed into a sparse component and a low-rank component. A new point spread function of Weiner filter is employed to efficiently remove blur in the sparse component; a wiener filtering with the Gaussian PSF is used to recover the average image of the low-rank component. And then we get the recovered CT image sequence by combining the recovery low-rank image with all recovery sparse image sequence. Our method achieves restoration results with higher contrast, sharper organ boundaries and richer soft tissue structure information, compared with existing CT image restoration methods. The robustness of our method was assessed with numerical experiments using three different low-rank models: Robust Principle Component Analysis (RPCA), Linearized Alternating Direction Method with Adaptive Penalty (LADMAP) and Go Decomposition (GoDec). Experimental results demonstrated that the RPCA model was the most suitable for the small noise CT images whereas the GoDec model was the best for the large noisy CT images. PMID:24023764

  6. Heterogeneity of Multiple Sclerosis Lesions in Multislice Myelin Water Imaging.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available To assess neuroprotection and remyelination in Multiple Sclerosis (MS, we applied a more robust myelin water imaging (MWI processing technique, including spatial priors into image reconstruction, which allows for lower SNR, less averages and shorter acquisition times. We sought to evaluate this technique in MS-patients and healthy controls (HC.Seventeen MS-patients and 14 age-matched HCs received a 3T Magnetic Resonance Imaging (MRI examination including MWI (8 slices, 12 minutes acquisition time, T2w and T1mprage pre and post gadolinium (GD administration. Black holes (BH, contrast enhancing lesions (CEL and T2 lesions were marked and registered to MWI. Additionally, regions of interest (ROI were defined in the frontal, parietal and occipital normal appearing white matter (NAWM/white matter (WM, the corticospinal tract (CST, the splenium (SCC and genu (GCC of the corpus callosum in patients and HCs. Mean values of myelin water fraction (MWF were determined for each ROI.Significant differences (p≤0.05 of the MWF were found in all three different MS-lesion types (BH, CEL, T2 lesions, compared to the WM of HCs. The mean MWF values among the different lesion types were significantly differing from each other. Comparing MS-patients vs. HCs, we found a significant (p≤0.05 difference of the MWF in all measured ROIs except of GCC and SCC. The mean reduction of MWF in the NAWM of MS-patients compared to HCs was 37%. No age, sex, disability score and disease duration dependency was found for the NAWM MWF.MWF measures were in line with previous studies and lesions were clearly visible in MWI. MWI allows for quantitative assessment of NAWM and lesions in MS, which could be used as an additional sensitive imaging endpoint for larger MS studies. Measurements of the MWF also differ between patients and healthy controls.

  7. Color correction with blind image restoration based on multiple images using a low-rank model

    Science.gov (United States)

    Li, Dong; Xie, Xudong; Lam, Kin-Man

    2014-03-01

    We present a method that can handle the color correction of multiple photographs with blind image restoration simultaneously and automatically. We prove that the local colors of a set of images of the same scene exhibit the low-rank property locally both before and after a color-correction operation. This property allows us to correct all kinds of errors in an image under a low-rank matrix model without particular priors or assumptions. The possible errors may be caused by changes of viewpoint, large illumination variations, gross pixel corruptions, partial occlusions, etc. Furthermore, a new iterative soft-segmentation method is proposed for local color transfer using color influence maps. Due to the fact that the correct color information and the spatial information of images can be recovered using the low-rank model, more precise color correction and many other image-restoration tasks-including image denoising, image deblurring, and gray-scale image colorizing-can be performed simultaneously. Experiments have verified that our method can achieve consistent and promising results on uncontrolled real photographs acquired from the Internet and that it outperforms current state-of-the-art methods.

  8. A comparative analysis of double inversion recovery TFE and TSE sequences on carotid artery wall imaging

    International Nuclear Information System (INIS)

    Chen Jun; Di Yujin; Bu Chunqing; Zhang Yanfeng; Li Shuhua

    2012-01-01

    Objective: To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. Patients and methods: 56 patients (32 males and 24 females, aged 31–76 years with a mean age of 53 years) were performed with DIR TFE and DIR TSE T1 weighted imaging (T1WI) sequences on carotid artery bifurcations. Image quality acquired by different techniques were evaluated and scored by two physicians. Whether there is significant difference is determined by SPSS 11.0 software. Paired-samples t test was used for statistics. Results: There was no significant difference in the image quality scores between two sequences (t = 0.880, P = 0.383 > 0.05). Conclusions: DIR TFE sequence has short scanning time and high spatial resolution. DIR TFE sequence can be used as the preferred sequence for screening carotid atherosclerotic plaque compared with DIR TSE sequence.

  9. Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging

    International Nuclear Information System (INIS)

    Lavdas, E.; Zaloni, E.; Vlychou, M.; Vassiou, K.; Fezoulidis, I.; Tsagkalis, A.; Dailiana, Z.

    2015-01-01

    To evaluate the ability of proton-density with fat-suppression BLADE (proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction in MR systems from Siemens Healthcare, PDFS BLADE) and turbo inversion recovery magnitude-BLADE (TIRM BLADE) sequences to reduce motion and pulsation artifacts in shoulder magnetic resonance examinations. Forty-one consecutive patients who had been routinely scanned for shoulder examination participated in the study. The following pairs of sequences with and without BLADE were compared: (a) Oblique coronal proton-density sequence with fat saturation of 25 patients and (b) oblique sagittal T2 TIRM-weighed sequence of 20 patients. Qualitative analysis was performed by two experienced radiologists. Image motion and pulsation artifacts were also evaluated. In oblique coronal PDFS BLADE sequences, motion artifacts have been significantly eliminated, even in five cases of non-diagnostic value with conventional imaging. Similarly, in oblique sagittal T2 TIRM BLADE sequences, image quality has been improved, even in six cases of non-diagnostic value with conventional imaging. Furthermore, flow artifacts have been improved in more than 80% of all the cases. The use of BLADE sequences is recommended in shoulder imaging, especially in uncooperative patients because it effectively eliminates motion and pulsation artifacts. (orig.)

  10. Robust segmentation of focal lesions on multi-sequence MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Garcia-Lorenzo, Daniel

    2010-01-01

    Multiple sclerosis (MS) affects around 80.000 people in France. Magnetic resonance imaging (MRI) is an essential tool for diagnosis of MS and MRI-derived surrogate markers such as MS lesion volumes are often used as measures in MS clinical trials for the development of new treatments. The manual segmentation of these MS lesions is a time-consuming task that shows high inter- and intra-rater variability. We developed an automatic work flow for the segmentation of focal MS lesions on MRI. The segmentation method is based on the robust estimation of a parametric model of the intensities of the brain; lesions are detected as outliers to the model. We proposed two methods to include spatial information in the segmentation using mean shift and graph cut. We performed a quantitative evaluation of our work flow using synthetic and clinical images of two different centers to verify its accuracy and robustness. (author)

  11. ClustalXeed: a GUI-based grid computation version for high performance and terabyte size multiple sequence alignment

    Directory of Open Access Journals (Sweden)

    Kim Taeho

    2010-09-01

    Full Text Available Abstract Background There is an increasing demand to assemble and align large-scale biological sequence data sets. The commonly used multiple sequence alignment programs are still limited in their ability to handle very large amounts of sequences because the system lacks a scalable high-performance computing (HPC environment with a greatly extended data storage capacity. Results We designed ClustalXeed, a software system for multiple sequence alignment with incremental improvements over previous versions of the ClustalX and ClustalW-MPI software. The primary advantage of ClustalXeed over other multiple sequence alignment software is its ability to align a large family of protein or nucleic acid sequences. To solve the conventional memory-dependency problem, ClustalXeed uses both physical random access memory (RAM and a distributed file-allocation system for distance matrix construction and pair-align computation. The computation efficiency of disk-storage system was markedly improved by implementing an efficient load-balancing algorithm, called "idle node-seeking task algorithm" (INSTA. The new editing option and the graphical user interface (GUI provide ready access to a parallel-computing environment for users who seek fast and easy alignment of large DNA and protein sequence sets. Conclusions ClustalXeed can now compute a large volume of biological sequence data sets, which were not tractable in any other parallel or single MSA program. The main developments include: 1 the ability to tackle larger sequence alignment problems than possible with previous systems through markedly improved storage-handling capabilities. 2 Implementing an efficient task load-balancing algorithm, INSTA, which improves overall processing times for multiple sequence alignment with input sequences of non-uniform length. 3 Support for both single PC and distributed cluster systems.

  12. Volume measurement of multiple sclerosis lesions with magnetic resonance images

    International Nuclear Information System (INIS)

    Wicks, D.A.G.; Tofts, P.S.; Miller, D.H.; Du Boulay, G.H.; Feinstein, A.; Harvey, I.; Brenner, R.; McDonald, W.I.; Sacares, R.P.

    1992-01-01

    The ability to visualise multiple sclerosis lesions in vivo with magnetic resonance imaging suggests an important role in monitoring the course of the disease. In order to help the long-term assessment of prospective treatments, a semi-automated technique for measuring lesion volume has been developed to provide a quantitative index of disease progression. Results are presented from a preliminary study with a single patient and compared to measurements taken from lesion outlines traced by a neuroradiologist, two neurologists and a technician. The semi-automated technique achieved a precision of 6% compared to a range of 12-33% for the manual tracing method. It also reduced the human interaction time from at least 60 min to 15 min. (orig.)

  13. Imaging by multiple modalities of patients with a carotidynia syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kosaka, Nobuyuki; Uematsu, Hidemasa; Kimura, Hirohiko; Itoh, Harumi [University of Fukui, Department of Radiology, Faculty of Medical Sciences, Fukui (Japan); Sagoh, Tadashi; Noguchi, Masato [Fukui Red Cross Hospital, Department of Radiology, Fukui (Japan); Miyayama, Shiro [Fukuiken Saiseikai Hospital, Department of Diagnostic Radiology, Fukui (Japan)

    2007-09-15

    The purpose of this article is to familiarize readers with the clinical syndrome of carotidynia. In the past, the International Headache Society (IHS) described idiopathic carotidynia as a diagnostic entity consisting of a self-limiting neck pain syndrome and tenderness over the carotid bifurcation without structural abnormality and then recently removed it from its classification. Although the clinical criteria of carotidynia in the former classification of the IHS included the absence of structural abnormality, several publications have demonstrated associated radiological findings and have described the usefulness of radiological investigations in diagnosing this syndrome. In this paper, we report four additional cases with a carotidynia clinical syndrome (according to the former classification) and the presence of abnormal soft tissue infiltration surrounding the symptomatic carotid artery as demonstrated by multiple imaging modalities, without any other underlying cause for the carotid pain syndrome. Our findings support the hypothesis that carotidynia could be a distinct disease entity, possibly caused by inflammation. (orig.)

  14. Image reconstruction from multiple fan-beam projections

    International Nuclear Information System (INIS)

    Jelinek, J.; Overton, T.R.

    1984-01-01

    Special-purpose third-generation fan-beam CT systems can be greatly simplified by limiting the number of detectors, but this requires a different mode of data collection to provide a set of projections appropriate to the required spatial resolution in the reconstructed image. Repeated rotation of the source-detector fan, combined with shift of the detector array and perhaps offset of the source with respect to the fan's axis after each 360 0 rotation(cycle), provides a fairly general pattern of projection space filling. The authors' investigated the problem of optimal data-collection geometry for a multiple-rotation fan-beam scanner and of corresponding reconstruction algorithm

  15. Imaging by multiple modalities of patients with a carotidynia syndrome

    International Nuclear Information System (INIS)

    Kosaka, Nobuyuki; Uematsu, Hidemasa; Kimura, Hirohiko; Itoh, Harumi; Sagoh, Tadashi; Noguchi, Masato; Miyayama, Shiro

    2007-01-01

    The purpose of this article is to familiarize readers with the clinical syndrome of carotidynia. In the past, the International Headache Society (IHS) described idiopathic carotidynia as a diagnostic entity consisting of a self-limiting neck pain syndrome and tenderness over the carotid bifurcation without structural abnormality and then recently removed it from its classification. Although the clinical criteria of carotidynia in the former classification of the IHS included the absence of structural abnormality, several publications have demonstrated associated radiological findings and have described the usefulness of radiological investigations in diagnosing this syndrome. In this paper, we report four additional cases with a carotidynia clinical syndrome (according to the former classification) and the presence of abnormal soft tissue infiltration surrounding the symptomatic carotid artery as demonstrated by multiple imaging modalities, without any other underlying cause for the carotid pain syndrome. Our findings support the hypothesis that carotidynia could be a distinct disease entity, possibly caused by inflammation. (orig.)

  16. Motion Estimation Using the Firefly Algorithm in Ultrasonic Image Sequence of Soft Tissue

    Directory of Open Access Journals (Sweden)

    Chih-Feng Chao

    2015-01-01

    Full Text Available Ultrasonic image sequence of the soft tissue is widely used in disease diagnosis; however, the speckle noises usually influenced the image quality. These images usually have a low signal-to-noise ratio presentation. The phenomenon gives rise to traditional motion estimation algorithms that are not suitable to measure the motion vectors. In this paper, a new motion estimation algorithm is developed for assessing the velocity field of soft tissue in a sequence of ultrasonic B-mode images. The proposed iterative firefly algorithm (IFA searches for few candidate points to obtain the optimal motion vector, and then compares it to the traditional iterative full search algorithm (IFSA via a series of experiments of in vivo ultrasonic image sequences. The experimental results show that the IFA can assess the vector with better efficiency and almost equal estimation quality compared to the traditional IFSA method.

  17. Research on Image Encryption Based on DNA Sequence and Chaos Theory

    Science.gov (United States)

    Tian Zhang, Tian; Yan, Shan Jun; Gu, Cheng Yan; Ren, Ran; Liao, Kai Xin

    2018-04-01

    Nowadays encryption is a common technique to protect image data from unauthorized access. In recent years, many scientists have proposed various encryption algorithms based on DNA sequence to provide a new idea for the design of image encryption algorithm. Therefore, a new method of image encryption based on DNA computing technology is proposed in this paper, whose original image is encrypted by DNA coding and 1-D logistic chaotic mapping. First, the algorithm uses two modules as the encryption key. The first module uses the real DNA sequence, and the second module is made by one-dimensional logistic chaos mapping. Secondly, the algorithm uses DNA complementary rules to encode original image, and uses the key and DNA computing technology to compute each pixel value of the original image, so as to realize the encryption of the whole image. Simulation results show that the algorithm has good encryption effect and security.

  18. MRI in multiple sclerosis of the spinal cord: evaluation of fast short-tan inversion-recovery and spin-echo sequences

    International Nuclear Information System (INIS)

    Dietemann, J.L.; Thibaut-Menard, A.; Neugroschl, C.; Gillis, C.; Abu Eid, M.; Bogorin, A.; Warter, J.M.; Tranchant, C.

    2000-01-01

    We compared the sensitivity of T2-weighted spin-echo (FSE) and fast short-tau inversion-recovery (fSTIR) sequences in detection of multiple sclerosis of the spinal cord in 100 consecutive patients with clinically confirmed multiple sclerosis (MS); 86 patients underwent also brain MRI. In all, 310 focal lesions were detected on fSTIR and 212 on T2-weighted FSE, spinal cord lesions were seen better on fSTIR images, with a higher contrast between the lesion and the normal spinal cord. In 24 patients in whom cord plaques were shown with both sequences, the cranial study was normal or inconclusive. Assessment of spinal plaques can be particularly important when MRI of the brain is inconclusive, and in there situations fSTIR can be helpful. (orig.)

  19. Multiple foci of splenic tissue autotransplantation: Splenosis in diagnostic imaging

    International Nuclear Information System (INIS)

    Laskowska, K.; Burzynska-Makuch, M.; Drewa, S.; Lasek, W.; Pilecki, S.; Junik, R.

    2005-01-01

    Splenosis is usually defined as an autotransplantation of lienal tissue in the abdomen or cest following trauma to the spleen and/or splenectomy. The authors present the case of patient 15 years after a splenectomy performed because of extensive abdominal trauma. A new computed tomographic (CT) scan of the abdomen revealed multiple homogenous nodules, different in size, spread in the abdomen. Their density was characteristic of spleen. Ultrasound examination revealed only the largest tumors, located close to the liver and apparently isoechogenic to it. Static scintigraphy and SPECT were performed to prove the presence of splenosis. After treating the patient with colloid sulfide, multiple foci of increased radioisotope accumulation were identified in the abdomen, extrahepatic at the same locations as the masses visible on the CT scans, which were comparable to splenic tissue. Nodules revealed during CT or abdominal US in patients previously treated by splenectomy require further imaging with static scintigraphy of the liver and spleen in order to confirm or exclude splenosis. (author)

  20. Evaluation of pneumonia in children: comparison of MRI with fast imaging sequences at 1.5T with chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Yikilmaz, Ali; Koc, Ali; Coskun, Abdulhakim (Dept. of Radiology, Erciyes Medical School, Kayseri (Turkey)); Ozturk, Mustafa K (Dept. of Pediatric Infectious Diseases, Erciyes Medical School, Kayseri (Turkey)); Mulkern, Robert V; Lee, Edward Y (Dept. of Radiology and Dept. of Medicine, Pulmonary Div., Children' s Hospital Boston and Harvard Medical School, Boston (United States)), email: Edward.lee@childrens.harvard.edu

    2011-10-15

    Background Although there has been a study aimed at magnetic resonance imaging (MRI) evaluation of pneumonia in children at a low magnetic field (0.2T), there is no study which assessed the efficacy of MRI, particularly with fast imaging sequences at 1.5T, for evaluating pneumonia in children. Purpose To investigate the efficacy of chest MRI with fast imaging sequences at 1.5T for evaluating pneumonia in children by comparing MRI findings with those of chest radiographs. Material and Methods This was an Institutional Review Board-approved, HIPPA-compliant prospective study of 40 consecutive pediatric patients (24 boys, 16 girls; mean age 7.3 years +- 6.6 years) with pneumonia, who underwent PA and lateral chest radiographs followed by MRI within 24 h. All MRI studies were obtained in axial and coronal planes with two different fast imaging sequences: T1-weighted FFE (Fast Field Echo) (TR/TE: 83/4.6) and T2-weighted B-FFE M2D (Balanced Fast Field Echo Multiple 2D Dimensional) (TR/TE: 3.2/1.6). Two experienced pediatric radiologists reviewed each chest radiograph and MRI for the presence of consolidation, necrosis/abscess, bronchiectasis, and pleural effusion. Chest radiograph and MRI findings were compared with Kappa statistics. Results All consolidation, lung necrosis/abscess, bronchiectasis, and pleural effusion detected with chest radiographs were also detected with MRI. There was statistically substantial agreement between chest radiographs and MRI in detecting consolidation (k = 0.78) and bronchiectasis (k = 0.72) in children with pneumonia. The agreement between chest radiographs and MRI was moderate for detecting necrosis/abscess (k = 0.49) and fair for detecting pleural effusion (k = 0.30). Conclusion MRI with fast imaging sequences is comparable to chest radiographs for evaluating underlying pulmonary consolidation, bronchiectasis, necrosis/abscess, and pleural effusion often associated with pneumonia in children

  1. Modern imaging techniques in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Bannas, Peter; Adam, G.; Derlin, T.; Kroeger, N.

    2013-01-01

    Imaging studies are essential for both diagnosis and initial staging of multiple myeloma, as well as for differentiation from other monoclonal plasma cell diseases. Apart from conventional radiography, a variety of newer imaging modalities including whole-body low-dose-CT, whole-body MRI and 18F-FDG PET/CT may be used for detection of osseous and extraosseous myeloma manifestations. Despite of known limitations such as limited sensitivity and specificity and the inability to detect extraosseous lesions, conventional radiography still remains the gold standard for staging newly diagnosed myeloma, partly due to its wide availability and low costs. Whole-body low-dose CT is increasingly used due to its higher sensitivity for the detection of osseous lesions and its ability to diagnose extraosseous lesions, and is replacing conventional radiography at selected centres. The highest sensitivity for both detection of bone marrow disease and extraosseous lesions can be achieved with whole-body MRI or 18F-FDG PET/CT. Diffuse bone marrow infiltration may be visualized by whole-body MRI with high sensitivity. Whole-body MRI is at least recommended in all patients with normal conventional radiography and in all patients with an apparently solitary plasmacytoma of bone. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of myeloma lesions are required. (orig.)

  2. Computer experiments of the time-sequence of individual steps in multiple Coulomb-excitation

    International Nuclear Information System (INIS)

    Boer, J. de; Dannhaueser, G.

    1982-01-01

    The way in which the multiple E2 steps in the Coulomb-excitation of a rotational band of a nucleus follow one another is elucidated for selected examples using semiclassical computer experiments. The role a given transition plays for the excitation of a given final state is measured by a quantity named ''importance function''. It is found that these functions, calculated for the highest rotational state, peak at times forming a sequence for the successive E2 transitions starting from the ground state. This sequential behaviour is used to approximately account for the effects on the projectile orbit of the sequential transfer of excitation energy and angular momentum from projectile to target. These orbits lead to similar deflection functions and cross sections as those obtained from a symmetrization procedure approximately accounting for the transfer of angular momentum and energy. (Auth.)

  3. ON THE MULTIPLICITY OF THE ZERO-AGE MAIN-SEQUENCE O STAR HERSCHEL 36

    International Nuclear Information System (INIS)

    Arias, Julia I.; Barba, Rodolfo H.; Gamen, Roberto C.; Morrell, Nidia I.; Apellaniz, Jesus MaIz; Alfaro, Emilio J.; Sota, Alfredo; Walborn, Nolan R.; Bidin, Christian Moni

    2010-01-01

    We present the analysis of high-resolution optical spectroscopic observations of the zero-age main-sequence O star Herschel 36 spanning six years. This star is definitely a multiple system, with at least three components detected in its spectrum. Based on our radial-velocity (RV) study, we propose a picture of a close massive binary and a more distant companion, most probably in wide orbit about each other. The orbital solution for the binary, whose components we identify as O9 V and B0.5 V, is characterized by a period of 1.5415 ± 0.0006 days. With a spectral type O7.5 V, the third body is the most luminous component of the system and also presents RV variations with a period close to 498 days. Some possible hypotheses to explain the variability are briefly addressed and further observations are suggested.

  4. TCS: a web server for multiple sequence alignment evaluation and phylogenetic reconstruction.

    Science.gov (United States)

    Chang, Jia-Ming; Di Tommaso, Paolo; Lefort, Vincent; Gascuel, Olivier; Notredame, Cedric

    2015-07-01

    This article introduces the Transitive Consistency Score (TCS) web server; a service making it possible to estimate the local reliability of protein multiple sequence alignments (MSAs) using the TCS index. The evaluation can be used to identify the aligned positions most likely to contain structurally analogous residues and also most likely to support an accurate phylogenetic reconstruction. The TCS scoring scheme has been shown to be accurate predictor of structural alignment correctness among commonly used methods. It has also been shown to outperform common filtering schemes like Gblocks or trimAl when doing MSA post-processing prior to phylogenetic tree reconstruction. The web server is available from http://tcoffee.crg.cat/tcs. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  5. Sequence-specific electrochemical recognition of multiple species using nanoparticle labels

    International Nuclear Information System (INIS)

    Cai Hong; Shang, Chii; Hsing, I.-Ming

    2004-01-01

    In this work, we report an electrochemical methodology that enables the rapid identification of different DNA sequences on the microfabricated electrodes. Our approach starts with an electropolymerization process on a patterned indium tin oxide (ITO)-coated glass electrode, followed by a selective immobilization of biotin-tagged probes on individually addressable spots via the biotin-streptavidin linkage. An exemplary target mixture containing E. coli and Stachybotrys Chartarum, an airborne pathogen, is then introduced. Recognition of the DNA hybridization event of the immobilized probes with the target pathogen PCR products or synthetic oligonucleotides is achieved by a novel electrochemistry-based technique utilizing the preferential catalytic silver electrodeposition process on the DNA-linked nanogold shells. The ability to selectively immobilize different oligonucleotide probes together with a sensitive electrochemistry-based detection for multiple species, as demonstrated in this study, is an important step forward for the realization of a portable bioanalytical microdevice for the rapid detection of pathogens

  6. Multiple endocrine neoplasia detection on I-123 MIBG imaging

    International Nuclear Information System (INIS)

    Reinhardt, C.A.; McEwan, L.M.; Wong, J.C.H.

    2000-01-01

    Full text: An 123 I meta-iodobenzylguanidine (MIBG) scan was performed on a 54-year-old lady with familial phaeochromocytoma, to evaluate for bilateral or extra-adrenal disease. She has hypertension with raised catecholamines and CT evidence of a right adrenal phaeochromocytoma, and a female sibling with bilateral phaeochromocytoma. Thyroid blockade using Lugol's Iodine was given orally prior to intravenous administration of 370 MBq 123 I MIBG. Planar and SPECT imaging were acquired at 24 hours. There was intense uptake in the known right phaeochromocytoma. An unexpected finding was focal intense uptake in the region of the right thyroid lobe, which may be either a functioning paraganglioma arising from the cervical sympathetic ganglia or a medullary thyroid carcinoma (MTC). At 48 hours, a further image of the neck showed no changes. This was followed by a standard injection of 150 MBq 99 Tc m pertechnetate for thyroid scanning. Imaging obtained on 99 Tc m energy window setting showed a large hypofunctioning region in the right thyroid lobe, corresponding in location to the focal 123 I MIBG uptake. This is in keeping with a MTC, a neuroendocrine tumour, as other thyroid carcinomas are non-MIBG avid. A subsequent serum calcitonin assay showed elevated levels. The patient underwent surgical removal of the right phaeochromocytoma followed several weeks later by a right hemithyroidectomy. Histological reports confirmed the tumour diagnoses. The patient's familial phaeochromocytoma is therefore part of the multiple endocrine neoplasia syndrome Type 2A (MEN 2A). To date, biochemistry has not shown any evidence of hyperparathyroidism which occurs in 15-20 per cent of patients with MEN 2A. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Spinal cord magnetic resonance imaging in suspected multiple sclerosis

    International Nuclear Information System (INIS)

    Lycklama a Nijeholt, G.J.; Bergers, E.; Castelijns, J.A.; Barkhof, F.; Uitdehaag, B.M.J.; Polman, C.H.

    2000-01-01

    We examined the value of spinal cord magnetic resonance imaging (MRI) in the diagnostic work-up of multiple sclerosis (MS). Forty patients suspected of having MS were examined within 24 months after the start of symptoms. Disability was assessed, and symptoms were categorized as either brain or spinal cord. Work-up further included cerebrospinal fluid analysis and standard proton-density, T2-, and T1-weighted gadolinium-enhanced brain and spinal cord MRI. Patients were categorized as either clinically definite MS (n = 13), laboratory-supported definite MS (n = 14), or clinically probable MS (n = 4); four patients had clinically probable MS, and in nine MS was suspected. Spinal cord abnormalities were found in 35 of 40 patients (87.5 %), consisting of focal lesions in 31, only diffuse abnormalities in two, and both in two. Asymptomatic spinal cord lesions occurred in six patients. All patients with diffuse spinal cord abnormality had clear spinal cord symptoms and a primary progressive disease course. In clinically definite MS, the inclusion of spinal imaging increased the sensitivity of MRI to 100 %. Seven patients without a definite diagnosis had clinically isolated syndromes involving the spinal cord. Brain MRI was inconclusive, while all had focal spinal cord lesions which explained symptoms and ruled out other causes. Two other patients had atypical brain abnormalities suggesting ischemic/vascular disease. No spinal cord abnormalities were found, and during follow-up MS was ruled out. Spinal cord abnormalities are common in suspected MS, and may occur asymptomatic. Although diagnostic classification is seldom changed, spinal cord imaging increases diagnostic sensitivity of MRI in patients with suspected MS. In addition, patients with primary progressive MS may possibly be earlier diagnosed. Finally, differentiation with atypical lesions may be improved. (orig.)

  8. Outdoor Illumination Estimation in Image Sequences for Augmented Reality

    DEFF Research Database (Denmark)

    Madsen, Claus B.; Lal, Brajesh Behari

    2011-01-01

    the detected shadows is used to estimate the radiance of the sun. The technique does not require special purpose objects in the scene, nor does it require High Dynamic Range imagery. Results are demonstrated by rendering augmented objects into real images with shading and shadows which are consistent...

  9. A Next-Generation Sequencing Strategy for Evaluating the Most Common Genetic Abnormalities in Multiple Myeloma.

    Science.gov (United States)

    Jiménez, Cristina; Jara-Acevedo, María; Corchete, Luis A; Castillo, David; Ordóñez, Gonzalo R; Sarasquete, María E; Puig, Noemí; Martínez-López, Joaquín; Prieto-Conde, María I; García-Álvarez, María; Chillón, María C; Balanzategui, Ana; Alcoceba, Miguel; Oriol, Albert; Rosiñol, Laura; Palomera, Luis; Teruel, Ana I; Lahuerta, Juan J; Bladé, Joan; Mateos, María V; Orfão, Alberto; San Miguel, Jesús F; González, Marcos; Gutiérrez, Norma C; García-Sanz, Ramón

    2017-01-01

    Identification and characterization of genetic alterations are essential for diagnosis of multiple myeloma and may guide therapeutic decisions. Currently, genomic analysis of myeloma to cover the diverse range of alterations with prognostic impact requires fluorescence in situ hybridization (FISH), single nucleotide polymorphism arrays, and sequencing techniques, which are costly and labor intensive and require large numbers of plasma cells. To overcome these limitations, we designed a targeted-capture next-generation sequencing approach for one-step identification of IGH translocations, V(D)J clonal rearrangements, the IgH isotype, and somatic mutations to rapidly identify risk groups and specific targetable molecular lesions. Forty-eight newly diagnosed myeloma patients were tested with the panel, which included IGH and six genes that are recurrently mutated in myeloma: NRAS, KRAS, HRAS, TP53, MYC, and BRAF. We identified 14 of 17 IGH translocations previously detected by FISH and three confirmed translocations not detected by FISH, with the additional advantage of breakpoint identification, which can be used as a target for evaluating minimal residual disease. IgH subclass and V(D)J rearrangements were identified in 77% and 65% of patients, respectively. Mutation analysis revealed the presence of missense protein-coding alterations in at least one of the evaluating genes in 16 of 48 patients (33%). This method may represent a time- and cost-effective diagnostic method for the molecular characterization of multiple myeloma. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  10. NMR imaging of solids with multiple-pulse line narrowing and radiofrequency gradients

    International Nuclear Information System (INIS)

    Werner, M.H.

    1993-01-01

    The usual methods of magnetic resonance imaging fail in rigid solids due to the line-shape contributions of dipolar coupling, chemical shift dispersion and anisotropy, and bulk magnetic susceptibility. This dissertation presents a new method of solid-stage imaging by nuclear magnetic resonance which averages away these contributions with multiple-pulse line-narrowing and encodes spatial information with pulsed radiofrequency field gradients. This method is closely related to simultaneously developed methods utilizing pulsed DC gradients, and offers similar improvements in sensitivity and resolution. The advantage of rf gradients is that they can be rapidly switched without inducing eddy currents in the probe or the magnet. In addition, the phases and amplitudes of the rf gradients can be switched by equipment which is already part of an NMR spectrometer capable of solid-state spectroscopy. The line-narrowing and gradient pulses originate in separate rf circuits tuned to the same frequency. Interactions between the circuits have been minimized by a method of active Q-switching which employs PIN diodes in the matching networks of these circuits. Both one- and two-dimensional images are presented. The latter are obtained by a novel method in which the two dimensions of imaging transverse to the static magnetic field are encoded by two orthogonal components of a single rf gradient. A π/2 phase shift of the rf phase relative to that of the line-narrowing pulses selects one component or the other. This arrangement allows the solid-state analogs of versatile imaging sequences based on Fourier imaging and eliminates the need for sample rotation and back-projection methods. Coherent averaging theory is used to analyze this imaging technique and exact numerical simulations on several coupled spins are discussed. These lend insight to the residual linewidth and its dependence on pixel position as well as to the range of applicability of this technique

  11. EPMLR: sequence-based linear B-cell epitope prediction method using multiple linear regression.

    Science.gov (United States)

    Lian, Yao; Ge, Meng; Pan, Xian-Ming

    2014-12-19

    B-cell epitopes have been studied extensively due to their immunological applications, such as peptide-based vaccine development, antibody production, and disease diagnosis and therapy. Despite several decades of research, the accurate prediction of linear B-cell epitopes has remained a challenging task. In this work, based on the antigen's primary sequence information, a novel linear B-cell epitope prediction model was developed using the multiple linear regression (MLR). A 10-fold cross-validation test on a large non-redundant dataset was performed to evaluate the performance of our model. To alleviate the problem caused by the noise of negative dataset, 300 experiments utilizing 300 sub-datasets were performed. We achieved overall sensitivity of 81.8%, precision of 64.1% and area under the receiver operating characteristic curve (AUC) of 0.728. We have presented a reliable method for the identification of linear B cell epitope using antigen's primary sequence information. Moreover, a web server EPMLR has been developed for linear B-cell epitope prediction: http://www.bioinfo.tsinghua.edu.cn/epitope/EPMLR/ .

  12. Estimates of statistical significance for comparison of individual positions in multiple sequence alignments

    Directory of Open Access Journals (Sweden)

    Sadreyev Ruslan I

    2004-08-01

    Full Text Available Abstract Background Profile-based analysis of multiple sequence alignments (MSA allows for accurate comparison of protein families. Here, we address the problems of detecting statistically confident dissimilarities between (1 MSA position and a set of predicted residue frequencies, and (2 between two MSA positions. These problems are important for (i evaluation and optimization of methods predicting residue occurrence at protein positions; (ii detection of potentially misaligned regions in automatically produced alignments and their further refinement; and (iii detection of sites that determine functional or structural specificity in two related families. Results For problems (1 and (2, we propose analytical estimates of P-value and apply them to the detection of significant positional dissimilarities in various experimental situations. (a We compare structure-based predictions of residue propensities at a protein position to the actual residue frequencies in the MSA of homologs. (b We evaluate our method by the ability to detect erroneous position matches produced by an automatic sequence aligner. (c We compare MSA positions that correspond to residues aligned by automatic structure aligners. (d We compare MSA positions that are aligned by high-quality manual superposition of structures. Detected dissimilarities reveal shortcomings of the automatic methods for residue frequency prediction and alignment construction. For the high-quality structural alignments, the dissimilarities suggest sites of potential functional or structural importance. Conclusion The proposed computational method is of significant potential value for the analysis of protein families.

  13. Phylogenetic Relationships of Pseudorasbora, Pseudopungtungia, and Pungtungia (Teleostei; Cypriniformes; Gobioninae Inferred from Multiple Nuclear Gene Sequences

    Directory of Open Access Journals (Sweden)

    Keun-Yong Kim

    2013-01-01

    Full Text Available Gobionine species belonging to the genera Pseudorasbora, Pseudopungtungia, and Pungtungia (Teleostei; Cypriniformes; Cyprinidae have been heavily studied because of problems on taxonomy, threats of extinction, invasion, and human health. Nucleotide sequences of three nuclear genes, that is, recombination activating protein gene 1 (rag1, recombination activating gene 2 (rag2, and early growth response 1 gene (egr1, from Pseudorasbora, Pseudopungtungia, and Pungtungia species residing in China, Japan, and Korea, were analyzed to elucidate their intergeneric and interspecific phylogenetic relationships. In the phylogenetic tree inferred from their multiple gene sequences, Pseudorasbora, Pseudopungtungia and Pungtungia species ramified into three phylogenetically distinct clades; the “tenuicorpa” clade composed of Pseudopungtungia tenuicorpa, the “parva” clade composed of all Pseudorasbora species/subspecies, and the “herzi” clade composed of Pseudopungtungia nigra, and Pungtungia herzi. The genus Pseudorasbora was recovered as monophyletic, while the genus Pseudopungtungia was recovered as polyphyletic. Our phylogenetic result implies the unstable taxonomic status of the genus Pseudopungtungia.

  14. Multiple ECG Fiducial Points-Based Random Binary Sequence Generation for Securing Wireless Body Area Networks.

    Science.gov (United States)

    Zheng, Guanglou; Fang, Gengfa; Shankaran, Rajan; Orgun, Mehmet A; Zhou, Jie; Qiao, Li; Saleem, Kashif

    2017-05-01

    Generating random binary sequences (BSes) is a fundamental requirement in cryptography. A BS is a sequence of N bits, and each bit has a value of 0 or 1. For securing sensors within wireless body area networks (WBANs), electrocardiogram (ECG)-based BS generation methods have been widely investigated in which interpulse intervals (IPIs) from each heartbeat cycle are processed to produce BSes. Using these IPI-based methods to generate a 128-bit BS in real time normally takes around half a minute. In order to improve the time efficiency of such methods, this paper presents an ECG multiple fiducial-points based binary sequence generation (MFBSG) algorithm. The technique of discrete wavelet transforms is employed to detect arrival time of these fiducial points, such as P, Q, R, S, and T peaks. Time intervals between them, including RR, RQ, RS, RP, and RT intervals, are then calculated based on this arrival time, and are used as ECG features to generate random BSes with low latency. According to our analysis on real ECG data, these ECG feature values exhibit the property of randomness and, thus, can be utilized to generate random BSes. Compared with the schemes that solely rely on IPIs to generate BSes, this MFBSG algorithm uses five feature values from one heart beat cycle, and can be up to five times faster than the solely IPI-based methods. So, it achieves a design goal of low latency. According to our analysis, the complexity of the algorithm is comparable to that of fast Fourier transforms. These randomly generated ECG BSes can be used as security keys for encryption or authentication in a WBAN system.

  15. Probabilistic Inference on Multiple Normalized Signal Profiles from Next Generation Sequencing: Transcription Factor Binding Sites

    KAUST Repository

    Wong, Ka-Chun; Peng, Chengbin; Li, Yue

    2015-01-01

    With the prevalence of chromatin immunoprecipitation (ChIP) with sequencing (ChIP-Seq) technology, massive ChIP-Seq data has been accumulated. The ChIP-Seq technology measures the genome-wide occupancy of DNA-binding proteins in vivo. It is well-known that different DNA-binding protein occupancies may result in a gene being regulated in different conditions (e.g. different cell types). To fully understand a gene's function, it is essential to develop probabilistic models on multiple ChIP-Seq profiles for deciphering the gene transcription causalities. In this work, we propose and describe two probabilistic models. Assuming the conditional independence of different DNA-binding proteins' occupancies, the first method (SignalRanker) is developed as an intuitive method for ChIP-Seq genome-wide signal profile inference. Unfortunately, such an assumption may not always hold in some gene regulation cases. Thus, we propose and describe another method (FullSignalRanker) which does not make the conditional independence assumption. The proposed methods are compared with other existing methods on ENCODE ChIP-Seq datasets, demonstrating its regression and classification ability. The results suggest that FullSignalRanker is the best-performing method for recovering the signal ranks on the promoter and enhancer regions. In addition, FullSignalRanker is also the best-performing method for peak sequence classification. We envision that SignalRanker and FullSignalRanker will become important in the era of next generation sequencing. FullSignalRanker program is available on the following website: http://www.cs.toronto.edu/∼wkc/FullSignalRanker/ © 2015 IEEE.

  16. Probabilistic Inference on Multiple Normalized Signal Profiles from Next Generation Sequencing: Transcription Factor Binding Sites

    KAUST Repository

    Wong, Ka-Chun

    2015-04-20

    With the prevalence of chromatin immunoprecipitation (ChIP) with sequencing (ChIP-Seq) technology, massive ChIP-Seq data has been accumulated. The ChIP-Seq technology measures the genome-wide occupancy of DNA-binding proteins in vivo. It is well-known that different DNA-binding protein occupancies may result in a gene being regulated in different conditions (e.g. different cell types). To fully understand a gene\\'s function, it is essential to develop probabilistic models on multiple ChIP-Seq profiles for deciphering the gene transcription causalities. In this work, we propose and describe two probabilistic models. Assuming the conditional independence of different DNA-binding proteins\\' occupancies, the first method (SignalRanker) is developed as an intuitive method for ChIP-Seq genome-wide signal profile inference. Unfortunately, such an assumption may not always hold in some gene regulation cases. Thus, we propose and describe another method (FullSignalRanker) which does not make the conditional independence assumption. The proposed methods are compared with other existing methods on ENCODE ChIP-Seq datasets, demonstrating its regression and classification ability. The results suggest that FullSignalRanker is the best-performing method for recovering the signal ranks on the promoter and enhancer regions. In addition, FullSignalRanker is also the best-performing method for peak sequence classification. We envision that SignalRanker and FullSignalRanker will become important in the era of next generation sequencing. FullSignalRanker program is available on the following website: http://www.cs.toronto.edu/∼wkc/FullSignalRanker/ © 2015 IEEE.

  17. Contrast-enhanced dynamic MR imaging of parasellar tumor using fast spin-echo sequence

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Ohue, Shiro; Ichikawa, Haruhisa; Saito, Masahiro; Sadamoto, Kazuhiko; Sakaki, Saburo; Miki, Hitoshi.

    1995-01-01

    We have applied a new dynamic MRI technique that uses a fast spin-echo sequence to parasellar tumors. This sequence has less susceptible effect and better spatial resolution than a gradient echo sequence, providing faster images than a short spin-echo sequence does. Image was obtained in the coronal or sagittal plane using a 1.5T clinical MRI system, and then, dynamic MR images were acquired every 10 to 20 sec after administration of Gd-DTPA (0.1 mmol/kg). The subjects were 12 patients (5 microadenomas, 5 macroadenomas and 2 Rathke's cleft cysts) and 5 normal volunteers. As for volunteers, the cavernous sinus, pituitary stalk and posterior pituitary gland were contrasted on the first image, followed by visualization of the proximal portion adjacent to the junction of the infundibulum and the anterior pituitary gland, and finally by contrasting the distal portion of the anterior pituitary gland. There was a difference with respect to tumor contrast between microadenomas and macroadenomas. In the case of the macroadenomas, the tumor was contrasted at the same time as, or faster than the anterior pituitary gland, while with the microadenomas the tumor was enhanced later than the anterior pituitary gland. No enhancement with contrast medium was seen in Rathke's cleft cysts. In addition, it was possible to differentiate a recurrent tumor from a piece of muscle placed at surgery since the images obtained by the fast spin-echo sequence were clearer than those obtained by gradient echo sequence. (author)

  18. The role of the STIR sequence in magnetic resonance imaging examination of bone tumours

    International Nuclear Information System (INIS)

    Golfieri, R.; Baddeley, H.; Pringle, J.S.; Souhami, R.

    1990-01-01

    Sixty patients with primary bone tumours were evaluated with magnetic resonance imaging (MRI) at 0.5 T with both conventional spin-echo (SE) and short inversion time inversion recovery (STIR) sequences. The STIR sequence with T 1 of 120-130 ms in all cases suppressed the high signal from fatty bone marrow, giving a clear depiction of tumour extent, in both its intramedullary and soft-tissue components, and is superior to conventional SE images. The high sensitivity (100% of our cases) of this technique is counterbalanced by its lack of specificity: on STIR sequences both tumour and peritumorous oedema give an increase of signal intensity, limiting assessment of tumour extent. Peritumoral oedema, only present in this series in malignant neoplasms, may however be differentiated on the basis of the configuration of the abnormal areas, and by comparing STIR images with short repetition time/echo time sequence results. (author)

  19. Multiple myoma: current recommendations for imaging; Multiples Myelom: Aktuelle Empfehlungen fuer die Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hillengass, J. [Medizinische Universitaetsklinik, Abteilung fuer Haematologie, Onkologie und Rheumatologie, Heidelberg (Germany); Deutsches Krebsforschungszentrum, Abteilung Radiologie E010, Heidelberg (Germany); Delorme, S. [Deutsches Krebsforschungszentrum, Abteilung Radiologie E010, Heidelberg (Germany)

    2012-04-15

    Imaging in monoclonal plasma cell disease serves to detect end organ damage, i.e., osteoporosis or bone destruction. Diffuse or circumscribed bone marrow infiltration without damage to mineralized bone is so far not regarded as end organ damage. Skeletal plain x-ray film survey to detect bone destruction, osteoporosis or fractures. Whole body low-dose computed tomography (CT) and whole body magnetic resonance imaging (MRI) allow a more sensitive assessment of both mineralized bone and bone marrow, with greater patient comfort and in the case of MRI without ionizing radiation. According to the literature, cross-sectional imaging is clearly superior to skeletal surveys and MRI is more sensitive than CT. Every locally destructive lesion will be detectable with MRI but for assessing the damage to mineralized bone CT is indispensible. The sensitivities of positron emission tomography (PET)/CT and MRI are comparable. If available whole body MRI and whole body low dose CT should replace conventional skeletal surveys. This has already been implemented in several centers in Germany. For the initial diagnosis of monoclonal gammopathy of undetermined significance (MGUS), smoldering multiple myeloma or symptomatic multiple myeloma, a whole-body MRI and a whole body low-dose CT should be performed. For MGUS and asymptomatic myeloma, whole body MRI only should be performed for follow-up until detection of first bone destruction. Patients with symptomatic multiple myeloma and known bone destruction will usually have whole body low-dose CT, supplemented by MRI studies where clinically required. (orig.) [German] Aufgabe der bildgebenden Diagnostik monoklonaler Plasmazellerkrankungen ist der Nachweis der Endorganschaedigung, d. h. der Osteoporose oder der Destruktion des mineralisierten Knochens. Die alleinige umschriebene oder diffuse Markrauminfiltration ohne knoecherne Destruktion gilt nach heutiger Konvention nicht als Endorganschaedigung. Konventioneller Roentgenskelettstatus

  20. Optimal context quantization in lossless compression of image data sequences

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Wu, X.; Andersen, Jakob Dahl

    2004-01-01

    In image compression context-based entropy coding is commonly used. A critical issue to the performance of context-based image coding is how to resolve the conflict of a desire for large templates to model high-order statistic dependency of the pixels and the problem of context dilution due...... to insufficient sample statistics of a given input image. We consider the problem of finding the optimal quantizer Q that quantizes the K-dimensional causal context C/sub t/=(X/sub t-t1/,X/sub t-t2/,...,X/sub t-tK/) of a source symbol X/sub t/ into one of a set of conditioning states. The optimality of context...... quantization is defined to be the minimum static or minimum adaptive code length of given a data set. For a binary source alphabet an optimal context quantizer can be computed exactly by a fast dynamic programming algorithm. Faster approximation solutions are also proposed. In case of m-ary source alphabet...

  1. OXBench: A benchmark for evaluation of protein multiple sequence alignment accuracy

    Directory of Open Access Journals (Sweden)

    Searle Stephen MJ

    2003-10-01

    Full Text Available Abstract Background The alignment of two or more protein sequences provides a powerful guide in the prediction of the protein structure and in identifying key functional residues, however, the utility of any prediction is completely dependent on the accuracy of the alignment. In this paper we describe a suite of reference alignments derived from the comparison of protein three-dimensional structures together with evaluation measures and software that allow automatically generated alignments to be benchmarked. We test the OXBench benchmark suite on alignments generated by the AMPS multiple alignment method, then apply the suite to compare eight different multiple alignment algorithms. The benchmark shows the current state-of-the art for alignment accuracy and provides a baseline against which new alignment algorithms may be judged. Results The simple hierarchical multiple alignment algorithm, AMPS, performed as well as or better than more modern methods such as CLUSTALW once the PAM250 pair-score matrix was replaced by a BLOSUM series matrix. AMPS gave an accuracy in Structurally Conserved Regions (SCRs of 89.9% over a set of 672 alignments. The T-COFFEE method on a data set of families with http://www.compbio.dundee.ac.uk. Conclusions The OXBench suite of reference alignments, evaluation software and results database provide a convenient method to assess progress in sequence alignment techniques. Evaluation measures that were dependent on comparison to a reference alignment were found to give good discrimination between methods. The STAMP Sc Score which is independent of a reference alignment also gave good discrimination. Application of OXBench in this paper shows that with the exception of T-COFFEE, the majority of the improvement in alignment accuracy seen since 1985 stems from improved pair-score matrices rather than algorithmic refinements. The maximum theoretical alignment accuracy obtained by pooling results over all methods was 94

  2. Probabilistic images (PBIS): A concise image representation technique for multiple parameters

    International Nuclear Information System (INIS)

    Wu, L.C.; Yeh, S.H.; Chen, Z.; Liu, R.S.

    1984-01-01

    Based on m parametric images (PIs) derived from a dynamic series (DS), each pixel of DS is regarded as an m-dimensional vector. Given one set of normal samples (pixels) N and another of abnormal samples A, probability density functions (pdfs) of both sets are estimated. Any unknown sample is classified into N or A by calculating the probability of its being in the abnormal set using the Bayes' theorem. Instead of estimating the multivariate pdfs, a distance ratio transformation is introduced to map the m-dimensional sample space to one dimensional Euclidean space. Consequently, the image that localizes the regional abnormalities is characterized by the probability of being abnormal. This leads to the new representation scheme of PBIs. Tc-99m HIDA study for detecting intrahepatic lithiasis (IL) was chosen as an example of constructing PBI from 3 parameters derived from DS and such a PBI was compared with those 3 PIs, namely, retention ratio image (RRI), peak time image (TNMAX) and excretion mean transit time image (EMTT). 32 normal subjects and 20 patients with proved IL were collected and analyzed. The resultant sensitivity and specificity of PBI were 97% and 98% respectively. They were superior to those of any of the 3 PIs: RRI (94/97), TMAX (86/88) and EMTT (94/97). Furthermore, the contrast of PBI was much better than that of any other image. This new image formation technique, based on multiple parameters, shows the functional abnormalities in a structural way. Its good contrast makes the interpretation easy. This technique is powerful compared to the existing parametric image method

  3. Detection of fast oscillating magnetic fields using dynamic multiple TR imaging and Fourier analysis.

    Directory of Open Access Journals (Sweden)

    Ki Hwan Kim

    Full Text Available Neuronal oscillations produce oscillating magnetic fields. There have been trials to detect neuronal oscillations using MRI, but the detectability in in vivo is still in debate. Major obstacles to detecting neuronal oscillations are (i weak amplitudes, (ii fast oscillations, which are faster than MRI temporal resolution, and (iii random frequencies and on/off intervals. In this study, we proposed a new approach for direct detection of weak and fast oscillating magnetic fields. The approach consists of (i dynamic acquisitions using multiple times to repeats (TRs and (ii an expanded frequency spectral analysis. Gradient echo echo-planar imaging was used to test the feasibility of the proposed approach with a phantom generating oscillating magnetic fields with various frequencies and amplitudes and random on/off intervals. The results showed that the proposed approach could precisely detect the weak and fast oscillating magnetic fields with random frequencies and on/off intervals. Complex and phase spectra showed reliable signals, while no meaningful signals were observed in magnitude spectra. A two-TR approach provided an absolute frequency spectrum above Nyquist sampling frequency pixel by pixel with no a priori target frequency information. The proposed dynamic multiple-TR imaging and Fourier analysis are promising for direct detection of neuronal oscillations and potentially applicable to any pulse sequences.

  4. Estimation of physiological parameters using knowledge-based factor analysis of dynamic nuclear medicine image sequences

    International Nuclear Information System (INIS)

    Yap, J.T.; Chen, C.T.; Cooper, M.

    1995-01-01

    The authors have previously developed a knowledge-based method of factor analysis to analyze dynamic nuclear medicine image sequences. In this paper, the authors analyze dynamic PET cerebral glucose metabolism and neuroreceptor binding studies. These methods have shown the ability to reduce the dimensionality of the data, enhance the image quality of the sequence, and generate meaningful functional images and their corresponding physiological time functions. The new information produced by the factor analysis has now been used to improve the estimation of various physiological parameters. A principal component analysis (PCA) is first performed to identify statistically significant temporal variations and remove the uncorrelated variations (noise) due to Poisson counting statistics. The statistically significant principal components are then used to reconstruct a noise-reduced image sequence as well as provide an initial solution for the factor analysis. Prior knowledge such as the compartmental models or the requirement of positivity and simple structure can be used to constrain the analysis. These constraints are used to rotate the factors to the most physically and physiologically realistic solution. The final result is a small number of time functions (factors) representing the underlying physiological processes and their associated weighting images representing the spatial localization of these functions. Estimation of physiological parameters can then be performed using the noise-reduced image sequence generated from the statistically significant PCs and/or the final factor images and time functions. These results are compared to the parameter estimation using standard methods and the original raw image sequences. Graphical analysis was performed at the pixel level to generate comparable parametric images of the slope and intercept (influx constant and distribution volume)

  5. CHROMATOGATE: A TOOL FOR DETECTING BASE MIS-CALLS IN MULTIPLE SEQUENCE ALIGNMENTS BY SEMI-AUTOMATIC CHROMATOGRAM INSPECTION

    Directory of Open Access Journals (Sweden)

    Nikolaos Alachiotis

    2013-03-01

    Full Text Available Automated DNA sequencers generate chromatograms that contain raw sequencing data. They also generate data that translates the chromatograms into molecular sequences of A, C, G, T, or N (undetermined characters. Since chromatogram translation programs frequently introduce errors, a manual inspection of the generated sequence data is required. As sequence numbers and lengths increase, visual inspection and manual correction of chromatograms and corresponding sequences on a per-peak and per-nucleotide basis becomes an error-prone, time-consuming, and tedious process. Here, we introduce ChromatoGate (CG, an open-source software that accelerates and partially automates the inspection of chromatograms and the detection of sequencing errors for bidirectional sequencing runs. To provide users full control over the error correction process, a fully automated error correction algorithm has not been implemented. Initially, the program scans a given multiple sequence alignment (MSA for potential sequencing errors, assuming that each polymorphic site in the alignment may be attributed to a sequencing error with a certain probability. The guided MSA assembly procedure in ChromatoGate detects chromatogram peaks of all characters in an alignment that lead to polymorphic sites, given a user-defined threshold. The threshold value represents the sensitivity of the sequencing error detection mechanism. After this pre-filtering, the user only needs to inspect a small number of peaks in every chromatogram to correct sequencing errors. Finally, we show that correcting sequencing errors is important, because population genetic and phylogenetic inferences can be misled by MSAs with uncorrected mis-calls. Our experiments indicate that estimates of population mutation rates can be affected two- to three-fold by uncorrected errors.

  6. HAlign-II: efficient ultra-large multiple sequence alignment and phylogenetic tree reconstruction with distributed and parallel computing.

    Science.gov (United States)

    Wan, Shixiang; Zou, Quan

    2017-01-01

    Multiple sequence alignment (MSA) plays a key role in biological sequence analyses, especially in phylogenetic tree construction. Extreme increase in next-generation sequencing results in shortage of efficient ultra-large biological sequence alignment approaches for coping with different sequence types. Distributed and parallel computing represents a crucial technique for accelerating ultra-large (e.g. files more than 1 GB) sequence analyses. Based on HAlign and Spark distributed computing system, we implement a highly cost-efficient and time-efficient HAlign-II tool to address ultra-large multiple biological sequence alignment and phylogenetic tree construction. The experiments in the DNA and protein large scale data sets, which are more than 1GB files, showed that HAlign II could save time and space. It outperformed the current software tools. HAlign-II can efficiently carry out MSA and construct phylogenetic trees with ultra-large numbers of biological sequences. HAlign-II shows extremely high memory efficiency and scales well with increases in computing resource. THAlign-II provides a user-friendly web server based on our distributed computing infrastructure. HAlign-II with open-source codes and datasets was established at http://lab.malab.cn/soft/halign.

  7. Comparison of 3 T and 7 T MRI clinical sequences for ankle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Juras, Vladimir, E-mail: vladimir.juras@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Slovak Academy of Sciences, Institute of Measurement Science, Dubravska cesta 9, 84104 Bratislava (Slovakia); Welsch, Goetz, E-mail: welsch@bwh.harvard.edu [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Baer, Peter, E-mail: baerpeter@siemens.com [Siemens Healthcare, Richard-Strauss-Strasse 76, D81679 Munich (Germany); Kronnerwetter, Claudia, E-mail: claudia.kronnerwetter@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria); Fujita, Hiroyuki, E-mail: hiroyuki.fujita@qualedyn.com [Quality Electrodynamics, LCC, 777 Beta Dr, Cleveland, OH 44143-2336 (United States); Trattnig, Siegfried, E-mail: siegfried.trattnig@meduniwien.ac.at [Medical University of Vienna, Department of Radiology, Vienna General Hospital, Waeringer Guertel 18-20, A-1090 Vienna (Austria)

    2012-08-15

    The purpose of this study was to compare 3 T and 7 T signal-to-noise and contrast-to noise ratios of clinical sequences for imaging of the ankles with optimized sequences and dedicated coils. Ten healthy volunteers were examined consecutively on both systems with three clinical sequences: (1) 3D gradient-echo, T{sub 1}-weighted; (2) 2D fast spin-echo, PD-weighted; and (3) 2D spin-echo, T{sub 1}-weighted. SNR was calculated for six regions: cartilage; bone; muscle; synovial fluid; Achilles tendon; and Kager's fat-pad. CNR was obtained for cartilage/bone, cartilage/fluid, cartilage/muscle, and muscle/fat-pad, and compared by a one-way ANOVA test for repeated measures. Mean SNR significantly increased at 7 T compared to 3 T for 3D GRE, and 2D TSE was 60.9% and 86.7%, respectively. In contrast, an average SNR decrease of almost 25% was observed in the 2D SE sequence. A CNR increase was observed in 2D TSE images, and in most 3D GRE images. There was a substantial benefit from ultra high-field MR imaging of ankles with routine clinical sequences at 7 T compared to 3 T. Higher SNR and CNR at ultra-high field MR scanners may be useful in clinical practice for ankle imaging. However, carefully optimized protocols and dedicated extremity coils are necessary to obtain optimal results.

  8. Temporal Sequence of Visuo-Auditory Interaction in Multiple Areas of the Guinea Pig Visual Cortex

    Science.gov (United States)

    Nishimura, Masataka; Song, Wen-Jie

    2012-01-01

    Recent studies in humans and monkeys have reported that acoustic stimulation influences visual responses in the primary visual cortex (V1). Such influences can be generated in V1, either by direct auditory projections or by feedback projections from extrastriate cortices. To test these hypotheses, cortical activities were recorded using optical imaging at a high spatiotemporal resolution from multiple areas of the guinea pig visual cortex, to visual and/or acoustic stimulations. Visuo-auditory interactions were evaluated according to differences between responses evoked by combined auditory and visual stimulation, and the sum of responses evoked by separate visual and auditory stimulations. Simultaneous presentation of visual and acoustic stimulations resulted in significant interactions in V1, which occurred earlier than in other visual areas. When acoustic stimulation preceded visual stimulation, significant visuo-auditory interactions were detected only in V1. These results suggest that V1 is a cortical origin of visuo-auditory interaction. PMID:23029483

  9. MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences

    International Nuclear Information System (INIS)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Hoermann, Marcus; Prayer, Daniela; Brugger, Peter C.; Csapo, Bence; Mittermayer, Christoph

    2007-01-01

    To purpose of this paper is to study the relation between normal lung maturation signal and changes in intensity ratios (SIR) and to determine which magnetic resonance imaging sequence provides the strongest correlation of normal lung SIs with gestational age. 126 normal singleton pregnancies (20-37 weeks) were examined with a 1.5 Tesla unit. Mean SIs for lungs, liver, and gastric fluid were assessed on six different sequences, and SIRs of lung/liver (LLSIR) and lung/gastric fluid (LGSIR) were correlated with gestational age for each sequence. To evaluate the feasibility of SIRs in the prediction of the state of the lung maturity, accuracy of the predicted SIRs (D*) was measured by calculating relative residuals (D*-D)/D for each sequence. LLSIRs showed significant changes in every sequence (p<0.05), while LGSIRs only on two sequences. Significant differences were shown for the mean of absolute residuals for both LLSIRs (p<0.001) and for LGSIRs (p=0.003). Relative residuals of LLSIRs were significantly smaller on T1-weighted sequence, whereas they were significantly higher for LGSIRs on FLAIR sequence. Fetal liver seems to be adequate reference for the investigation of lung maturation. T1-weighted sequence was the most accurate for the measurement of the lung SIs; thus, we propose to determine LLSIR on T1-weighted sequence when evaluating lung development. (orig.)

  10. MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Balassy, Csilla; Kasprian, Gregor; Weber, Michael; Hoermann, Marcus; Prayer, Daniela [Medical University of Vienna, Department of Radiology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Center of Anatomy and Cell Biology, Vienna (Austria); Csapo, Bence [Medical University of Vienna, Department of Obstetrics and Gyneocology, Vienna (Austria); Mittermayer, Christoph [Medical University of Vienna, Department of Pediatrics, Vienna (Austria)

    2007-03-15

    To purpose of this paper is to study the relation between normal lung maturation signal and changes in intensity ratios (SIR) and to determine which magnetic resonance imaging sequence provides the strongest correlation of normal lung SIs with gestational age. 126 normal singleton pregnancies (20-37 weeks) were examined with a 1.5 Tesla unit. Mean SIs for lungs, liver, and gastric fluid were assessed on six different sequences, and SIRs of lung/liver (LLSIR) and lung/gastric fluid (LGSIR) were correlated with gestational age for each sequence. To evaluate the feasibility of SIRs in the prediction of the state of the lung maturity, accuracy of the predicted SIRs (D*) was measured by calculating relative residuals (D*-D)/D for each sequence. LLSIRs showed significant changes in every sequence (p<0.05), while LGSIRs only on two sequences. Significant differences were shown for the mean of absolute residuals for both LLSIRs (p<0.001) and for LGSIRs (p=0.003). Relative residuals of LLSIRs were significantly smaller on T1-weighted sequence, whereas they were significantly higher for LGSIRs on FLAIR sequence. Fetal liver seems to be adequate reference for the investigation of lung maturation. T1-weighted sequence was the most accurate for the measurement of the lung SIs; thus, we propose to determine LLSIR on T1-weighted sequence when evaluating lung development. (orig.)

  11. Segmentation of multiple sclerosis lesions in MR images: a review

    Energy Technology Data Exchange (ETDEWEB)

    Mortazavi, Daryoush; Kouzani, Abbas Z. [Deakin University, School of Engineering, Geelong, Victoria (Australia); Soltanian-Zadeh, Hamid [Henry Ford Health System, Image Analysis Laboratory, Radiology Department, Detroit, MI (United States); University of Tehran, Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, Tehran (Iran, Islamic Republic of); School of Cognitive Sciences, Institute for Studies in Theoretical Physics and Mathematics (IPM), Tehran (Iran, Islamic Republic of)

    2012-04-15

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  12. Segmentation of multiple sclerosis lesions in MR images: a review

    International Nuclear Information System (INIS)

    Mortazavi, Daryoush; Kouzani, Abbas Z.; Soltanian-Zadeh, Hamid

    2012-01-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  13. Use of the Discrete Cosine Transform for the restoration of an image sequence

    International Nuclear Information System (INIS)

    Acheroy, M.P.J.

    1985-01-01

    The Discrete Cosine Transform (DCT) is recognized as an important tool for image compression techniques. Its use in image restoration is, however, not well known. It is the aim of this paper to provide a restoration method for a sequence of images using the DCT as well for the deblurring as for the noise reduction. It is shown that the DCT can play an interesting role in the deconvolution problem for linear imaging systems with finite, invariant and symmetric impulse response. It is further shown that the noise reduction can be performed onto an image sequence using a time adaptive Kalman filter in the domain of the Karhunen-Loeve transform which is approximated by the DCT

  14. Meteor localization via statistical analysis of spatially temporal fluctuations in image sequences

    Science.gov (United States)

    Kukal, Jaromír.; Klimt, Martin; Šihlík, Jan; Fliegel, Karel

    2015-09-01

    Meteor detection is one of the most important procedures in astronomical imaging. Meteor path in Earth's atmosphere is traditionally reconstructed from double station video observation system generating 2D image sequences. However, the atmospheric turbulence and other factors cause spatially-temporal fluctuations of image background, which makes the localization of meteor path more difficult. Our approach is based on nonlinear preprocessing of image intensity using Box-Cox and logarithmic transform as its particular case. The transformed image sequences are then differentiated along discrete coordinates to obtain statistical description of sky background fluctuations, which can be modeled by multivariate normal distribution. After verification and hypothesis testing, we use the statistical model for outlier detection. Meanwhile the isolated outlier points are ignored, the compact cluster of outliers indicates the presence of meteoroids after ignition.

  15. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  16. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  17. Fat-saturated diffusion-weighted imaging with three-dimensional MP-RAGE sequence

    International Nuclear Information System (INIS)

    Numano, Tomokazu; Homma, Kazuhiro; Takahashi, Nobuyuki; Hirose, Takeshi

    2005-01-01

    Image misrepresentation due to chemical shifts can create image artifacts on MR images. Distinguishing the organization and affected area can be difficult due to the chemical shift artifacts. Chemical shift selective (CHESS) is a method of decreasing chemical shift artifacts. In this study we have developed a new sequence for fat-saturated three-dimensional diffusion weighted MR imaging. This imaging was done during in vivo studies using an animal experiment MR imaging system at 2.0 T. In this sequence a preparation phase with a ''CHESS-90 deg RF-Motion Proving Gradient (MPG-180 deg RF-MPG-90 deg RF pulse train) was used to sensitize the magnetization to fat-saturated diffusion. Centric k-space acquisition order is necessary to minimize saturation effects from tissues with short relaxation times. From experimental results obtained with a phantom, the effect of the diffusion weighting and the effect of the fat-saturation were confirmed. From rat experimental results, fat-saturated diffusion weighted image data (0.55 x 0.55 x 0.55 mm 3 : voxel size) were obtained. This sequence was useful for in vivo imaging. (author)

  18. Multiple viral infections in Agaricus bisporus - Characterisation of 18 unique RNA viruses and 8 ORFans identified by deep sequencing

    OpenAIRE

    Deakin, Gregory; Dobbs, Edward; Bennett, Julie M.; Jones, Ian M.; Grogan, Helen M.; Burton, Kerry S.

    2017-01-01

    Thirty unique non-host RNAs were sequenced in the cultivated fungus, Agaricus bisporus, comprising 18 viruses each encoding an RdRp domain with an additional 8 ORFans (non-host RNAs with no similarity to known sequences). Two viruses were multipartite with component RNAs showing correlative abundances and common 3′ motifs. The viruses, all positive sense single-stranded, were classified into diverse orders/families. Multiple infections of Agaricus may represent a diverse, dynamic and interact...

  19. Differential evolution optimization combined with chaotic sequences for image contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Santos Coelho, Leandro dos [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: leandro.coelho@pucpr.br; Sauer, Joao Guilherme [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: joao.sauer@gmail.com; Rudek, Marcelo [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: marcelo.rudek@pucpr.br

    2009-10-15

    Evolutionary Algorithms (EAs) are stochastic and robust meta-heuristics of evolutionary computation field useful to solve optimization problems in image processing applications. Recently, as special mechanism to avoid being trapped in local minimum, the ergodicity property of chaotic sequences has been used in various designs of EAs. Three differential evolution approaches based on chaotic sequences using logistic equation for image enhancement process are proposed in this paper. Differential evolution is a simple yet powerful evolutionary optimization algorithm that has been successfully used in solving continuous problems. The proposed chaotic differential evolution schemes have fast convergence rate but also maintain the diversity of the population so as to escape from local optima. In this paper, the image contrast enhancement is approached as a constrained nonlinear optimization problem. The objective of the proposed chaotic differential evolution schemes is to maximize the fitness criterion in order to enhance the contrast and detail in the image by adapting the parameters using a contrast enhancement technique. The proposed chaotic differential evolution schemes are compared with classical differential evolution to two testing images. Simulation results on three images show that the application of chaotic sequences instead of random sequences is a possible strategy to improve the performance of classical differential evolution optimization algorithm.

  20. Identification of multiple mRNA and DNA sequences from small tissue samples isolated by laser-assisted microdissection.

    Science.gov (United States)

    Bernsen, M R; Dijkman, H B; de Vries, E; Figdor, C G; Ruiter, D J; Adema, G J; van Muijen, G N

    1998-10-01

    Molecular analysis of small tissue samples has become increasingly important in biomedical studies. Using a laser dissection microscope and modified nucleic acid isolation protocols, we demonstrate that multiple mRNA as well as DNA sequences can be identified from a single-cell sample. In addition, we show that the specificity of procurement of tissue samples is not compromised by smear contamination resulting from scraping of the microtome knife during sectioning of lesions. The procedures described herein thus allow for efficient RT-PCR or PCR analysis of multiple nucleic acid sequences from small tissue samples obtained by laser-assisted microdissection.

  1. Development of an image intensifier-TV digital imaging system with a multiple-slit scanning x-ray beam

    International Nuclear Information System (INIS)

    Kume, Y.; Doi, K.

    1986-01-01

    The authors are developing a new digital x-ray imaging system employing a multiple-slit assembly (MSA) and an image intensifier (II)-TV digital system. The final image consisting of primary radiation is digitally reconstructed from multiple slit images obtained with the MSA. This system can significantly reduce the scattered radiation from an object and the veiling glare from II-TV system. The quality of the reconstructed image is related to many parameters, such as slit width, the number of image frames, and the image reconstruction algorithm. They present the effect of these various parameters on basic imaging properties and the practicability of the method in comparison with conventional wide beam imaging

  2. Embedded-Based Graphics Processing Unit Cluster Platform for Multiple Sequence Alignments

    Directory of Open Access Journals (Sweden)

    Jyh-Da Wei

    2017-08-01

    Full Text Available High-end graphics processing units (GPUs, such as NVIDIA Tesla/Fermi/Kepler series cards with thousands of cores per chip, are widely applied to high-performance computing fields in a decade. These desktop GPU cards should be installed in personal computers/servers with desktop CPUs, and the cost and power consumption of constructing a GPU cluster platform are very high. In recent years, NVIDIA releases an embedded board, called Jetson Tegra K1 (TK1, which contains 4 ARM Cortex-A15 CPUs and 192 Compute Unified Device Architecture cores (belong to Kepler GPUs. Jetson Tegra K1 has several advantages, such as the low cost, low power consumption, and high applicability, and it has been applied into several specific applications. In our previous work, a bioinformatics platform with a single TK1 (STK platform was constructed, and this previous work is also used to prove that the Web and mobile services can be implemented in the STK platform with a good cost-performance ratio by comparing a STK platform with the desktop CPU and GPU. In this work, an embedded-based GPU cluster platform will be constructed with multiple TK1s (MTK platform. Complex system installation and setup are necessary procedures at first. Then, 2 job assignment modes are designed for the MTK platform to provide services for users. Finally, ClustalW v2.0.11 and ClustalWtk will be ported to the MTK platform. The experimental results showed that the speedup ratios achieved 5.5 and 4.8 times for ClustalW v2.0.11 and ClustalWtk, respectively, by comparing 6 TK1s with a single TK1. The MTK platform is proven to be useful for multiple sequence alignments.

  3. Embedded-Based Graphics Processing Unit Cluster Platform for Multiple Sequence Alignments.

    Science.gov (United States)

    Wei, Jyh-Da; Cheng, Hui-Jun; Lin, Chun-Yuan; Ye, Jin; Yeh, Kuan-Yu

    2017-01-01

    High-end graphics processing units (GPUs), such as NVIDIA Tesla/Fermi/Kepler series cards with thousands of cores per chip, are widely applied to high-performance computing fields in a decade. These desktop GPU cards should be installed in personal computers/servers with desktop CPUs, and the cost and power consumption of constructing a GPU cluster platform are very high. In recent years, NVIDIA releases an embedded board, called Jetson Tegra K1 (TK1), which contains 4 ARM Cortex-A15 CPUs and 192 Compute Unified Device Architecture cores (belong to Kepler GPUs). Jetson Tegra K1 has several advantages, such as the low cost, low power consumption, and high applicability, and it has been applied into several specific applications. In our previous work, a bioinformatics platform with a single TK1 (STK platform) was constructed, and this previous work is also used to prove that the Web and mobile services can be implemented in the STK platform with a good cost-performance ratio by comparing a STK platform with the desktop CPU and GPU. In this work, an embedded-based GPU cluster platform will be constructed with multiple TK1s (MTK platform). Complex system installation and setup are necessary procedures at first. Then, 2 job assignment modes are designed for the MTK platform to provide services for users. Finally, ClustalW v2.0.11 and ClustalWtk will be ported to the MTK platform. The experimental results showed that the speedup ratios achieved 5.5 and 4.8 times for ClustalW v2.0.11 and ClustalWtk, respectively, by comparing 6 TK1s with a single TK1. The MTK platform is proven to be useful for multiple sequence alignments.

  4. A novel color image encryption scheme using fractional-order hyperchaotic system and DNA sequence operations

    International Nuclear Information System (INIS)

    Zhang Li-Min; Sun Ke-Hui; Liu Wen-Hao; He Shao-Bo

    2017-01-01

    In this paper, Adomian decomposition method (ADM) with high accuracy and fast convergence is introduced to solve the fractional-order piecewise-linear (PWL) hyperchaotic system. Based on the obtained hyperchaotic sequences, a novel color image encryption algorithm is proposed by employing a hybrid model of bidirectional circular permutation and DNA masking. In this scheme, the pixel positions of image are scrambled by circular permutation, and the pixel values are substituted by DNA sequence operations. In the DNA sequence operations, addition and substraction operations are performed according to traditional addition and subtraction in the binary, and two rounds of addition rules are used to encrypt the pixel values. The simulation results and security analysis show that the hyperchaotic map is suitable for image encryption, and the proposed encryption algorithm has good encryption effect and strong key sensitivity. It can resist brute-force attack, statistical attack, differential attack, known-plaintext, and chosen-plaintext attacks. (paper)

  5. Small-target leak detection for a closed vessel via infrared image sequences

    Science.gov (United States)

    Zhao, Ling; Yang, Hongjiu

    2017-03-01

    This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.

  6. Parry-Romberg syndrome: findings in advanced magnetic resonance imaging sequences - case report

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Rafael Alfenas de; Ribeiro, Bruno Niemeyer de Freitas, E-mail: alfenas85@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho; Bahia, Paulo Roberto Valle [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de radiologia; Ribeiro, Renato Niemeyer de Freitas [Hospital de Clinica de Jacarepagua, Rio de Janeiro, RJ (Brazil); Carvalho, Lais Balbi de [Universidade Presidente Antonio Carlos (Unipac), Juiz de Fora, MG (Brazil)

    2014-05-15

    Parry-Romberg syndrome is a rare disease characterized by progressive hemifacial atrophy associated with other systemic changes, including neurological symptoms. Currently, there are few studies exploring the utilization of advanced magnetic resonance sequences in the investigation of this disease. The authors report the case of a 45-year-old patient and describe the findings at structural magnetic resonance imaging and at advanced sequences, correlating them with pathophysiological data. (author)

  7. Artificial Intelligence In Processing A Sequence Of Time-Varying Images

    Science.gov (United States)

    Siler, W.; Tucker, D.; Buckley, J.; Hess, R. G.; Powell, V. G.

    1985-04-01

    A computer system is described for unsupervised analysis of five sets of ultrasound images of the heart. Each set consists of 24 frames taken at 33 millisecond intervals. The images are acquired in real time with computer control of the ultrasound apparatus. After acquisition the images are segmented by a sequence of image-processing programs; features are extracted and stored in a version of the Carnegie- Mellon Blackboard. Region classification is accomplished by a fuzzy logic expert system FLOPS based on OPS5. Preliminary results are given.

  8. Digital Droplet Multiple Displacement Amplification (ddMDA for Whole Genome Sequencing of Limited DNA Samples.

    Directory of Open Access Journals (Sweden)

    Minsoung Rhee

    Full Text Available Multiple displacement amplification (MDA is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently, the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet, ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.

  9. GenNon-h: Generating multiple sequence alignments on nonhomogeneous phylogenetic trees

    Directory of Open Access Journals (Sweden)

    Kedzierska Anna M

    2012-08-01

    Full Text Available Abstract Background A number of software packages are available to generate DNA multiple sequence alignments (MSAs evolved under continuous-time Markov processes on phylogenetic trees. On the other hand, methods of simulating the DNA MSA directly from the transition matrices do not exist. Moreover, existing software restricts to the time-reversible models and it is not optimized to generate nonhomogeneous data (i.e. placing distinct substitution rates at different lineages. Results We present the first package designed to generate MSAs evolving under discrete-time Markov processes on phylogenetic trees, directly from probability substitution matrices. Based on the input model and a phylogenetic tree in the Newick format (with branch lengths measured as the expected number of substitutions per site, the algorithm produces DNA alignments of desired length. GenNon-h is publicly available for download. Conclusion The software presented here is an efficient tool to generate DNA MSAs on a given phylogenetic tree. GenNon-h provides the user with the nonstationary or nonhomogeneous phylogenetic data that is well suited for testing complex biological hypotheses, exploring the limits of the reconstruction algorithms and their robustness to such models.

  10. Rapid and Sensitive Isothermal Detection of Nucleic-acid Sequence by Multiple Cross Displacement Amplification.

    Science.gov (United States)

    Wang, Yi; Wang, Yan; Ma, Ai-Jing; Li, Dong-Xun; Luo, Li-Juan; Liu, Dong-Xin; Jin, Dong; Liu, Kai; Ye, Chang-Yun

    2015-07-08

    We have devised a novel amplification strategy based on isothermal strand-displacement polymerization reaction, which was termed multiple cross displacement amplification (MCDA). The approach employed a set of ten specially designed primers spanning ten distinct regions of target sequence and was preceded at a constant temperature (61-65 °C). At the assay temperature, the double-stranded DNAs were at dynamic reaction environment of primer-template hybrid, thus the high concentration of primers annealed to the template strands without a denaturing step to initiate the synthesis. For the subsequent isothermal amplification step, a series of primer binding and extension events yielded several single-stranded DNAs and single-stranded single stem-loop DNA structures. Then, these DNA products enabled the strand-displacement reaction to enter into the exponential amplification. Three mainstream methods, including colorimetric indicators, agarose gel electrophoresis and real-time turbidity, were selected for monitoring the MCDA reaction. Moreover, the practical application of the MCDA assay was successfully evaluated by detecting the target pathogen nucleic acid in pork samples, which offered advantages on quick results, modest equipment requirements, easiness in operation, and high specificity and sensitivity. Here we expounded the basic MCDA mechanism and also provided details on an alternative (Single-MCDA assay, S-MCDA) to MCDA technique.

  11. MSAProbs-MPI: parallel multiple sequence aligner for distributed-memory systems.

    Science.gov (United States)

    González-Domínguez, Jorge; Liu, Yongchao; Touriño, Juan; Schmidt, Bertil

    2016-12-15

    MSAProbs is a state-of-the-art protein multiple sequence alignment tool based on hidden Markov models. It can achieve high alignment accuracy at the expense of relatively long runtimes for large-scale input datasets. In this work we present MSAProbs-MPI, a distributed-memory parallel version of the multithreaded MSAProbs tool that is able to reduce runtimes by exploiting the compute capabilities of common multicore CPU clusters. Our performance evaluation on a cluster with 32 nodes (each containing two Intel Haswell processors) shows reductions in execution time of over one order of magnitude for typical input datasets. Furthermore, MSAProbs-MPI using eight nodes is faster than the GPU-accelerated QuickProbs running on a Tesla K20. Another strong point is that MSAProbs-MPI can deal with large datasets for which MSAProbs and QuickProbs might fail due to time and memory constraints, respectively. Source code in C ++ and MPI running on Linux systems as well as a reference manual are available at http://msaprobs.sourceforge.net CONTACT: jgonzalezd@udc.esSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  13. Denoising time-resolved microscopy image sequences with singular value thresholding

    Energy Technology Data Exchange (ETDEWEB)

    Furnival, Tom, E-mail: tjof2@cam.ac.uk; Leary, Rowan K., E-mail: rkl26@cam.ac.uk; Midgley, Paul A., E-mail: pam33@cam.ac.uk

    2017-07-15

    Time-resolved imaging in microscopy is important for the direct observation of a range of dynamic processes in both the physical and life sciences. However, the image sequences are often corrupted by noise, either as a result of high frame rates or a need to limit the radiation dose received by the sample. Here we exploit both spatial and temporal correlations using low-rank matrix recovery methods to denoise microscopy image sequences. We also make use of an unbiased risk estimator to address the issue of how much thresholding to apply in a robust and automated manner. The performance of the technique is demonstrated using simulated image sequences, as well as experimental scanning transmission electron microscopy data, where surface adatom motion and nanoparticle structural dynamics are recovered at rates of up to 32 frames per second. - Highlights: • Correlations in space and time are harnessed to denoise microscopy image sequences. • A robust estimator provides automated selection of the denoising parameter. • Motion tracking and automated noise estimation provides a versatile algorithm. • Application to time-resolved STEM enables study of atomic and nanoparticle dynamics.

  14. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    Science.gov (United States)

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68 Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68 Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count

  15. Inter frame motion estimation and its application to image sequence compression: an introduction

    International Nuclear Information System (INIS)

    Cremy, C.

    1996-01-01

    With the constant development of new communication technologies like, digital TV, teleconference, and the development of image analysis applications, there is a growing volume of data to manage. Compression techniques are required for the transmission and storage of these data. Dealing with original images would require the use of expansive high bandwidth communication devices and huge storage media. Image sequence compression can be achieved by means of interframe estimation that consists in retrieving redundant information relative to zones where there is little motion between two frames. This paper is an introduction to some motion estimation techniques like gradient techniques, pel-recursive, block-matching, and its application to image sequence compression. (Author) 17 refs

  16. Formation of a Multiple Protein Complex on the Adenovirus Packaging Sequence by the IVa2 Protein▿

    OpenAIRE

    Tyler, Ryan E.; Ewing, Sean G.; Imperiale, Michael J.

    2007-01-01

    During adenovirus virion assembly, the packaging sequence mediates the encapsidation of the viral genome. This sequence is composed of seven functional units, termed A repeats. Recent evidence suggests that the adenovirus IVa2 protein binds the packaging sequence and is involved in packaging of the genome. Study of the IVa2-packaging sequence interaction has been hindered by difficulty in purifying the protein produced in virus-infected cells or by recombinant techniques. We report the first ...

  17. Pseudo-random Trees: Multiple Independent Sequence Generators for Parallel and Branching Computations

    Science.gov (United States)

    Halton, John H.

    1989-09-01

    A class of families of linear congruential pseudo-random sequences is defined, for which it is possible to branch at any event without changing the sequence of random numbers used in the original random walk and for which the sequences in different branches show properties analogous to mutual statistical independence. This is a hitherto unavailable, and computationally desirable, tool.

  18. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  19. Rapid 3D Reconstruction for Image Sequence Acquired from UAV Camera

    Directory of Open Access Journals (Sweden)

    Yufu Qu

    2018-01-01

    Full Text Available In order to reconstruct three-dimensional (3D structures from an image sequence captured by unmanned aerial vehicles’ camera (UAVs and improve the processing speed, we propose a rapid 3D reconstruction method that is based on an image queue, considering the continuity and relevance of UAV camera images. The proposed approach first compresses the feature points of each image into three principal component points by using the principal component analysis method. In order to select the key images suitable for 3D reconstruction, the principal component points are used to estimate the interrelationships between images. Second, these key images are inserted into a fixed-length image queue. The positions and orientations of the images are calculated, and the 3D coordinates of the feature points are estimated using weighted bundle adjustment. With this structural information, the depth maps of these images can be calculated. Next, we update the image queue by deleting some of the old images and inserting some new images into the queue, and a structural calculation of all the images can be performed by repeating the previous steps. Finally, a dense 3D point cloud can be obtained using the depth–map fusion method. The experimental results indicate that when the texture of the images is complex and the number of images exceeds 100, the proposed method can improve the calculation speed by more than a factor of four with almost no loss of precision. Furthermore, as the number of images increases, the improvement in the calculation speed will become more noticeable.

  20. Rapid 3D Reconstruction for Image Sequence Acquired from UAV Camera.

    Science.gov (United States)

    Qu, Yufu; Huang, Jianyu; Zhang, Xuan

    2018-01-14

    In order to reconstruct three-dimensional (3D) structures from an image sequence captured by unmanned aerial vehicles' camera (UAVs) and improve the processing speed, we propose a rapid 3D reconstruction method that is based on an image queue, considering the continuity and relevance of UAV camera images. The proposed approach first compresses the feature points of each image into three principal component points by using the principal component analysis method. In order to select the key images suitable for 3D reconstruction, the principal component points are used to estimate the interrelationships between images. Second, these key images are inserted into a fixed-length image queue. The positions and orientations of the images are calculated, and the 3D coordinates of the feature points are estimated using weighted bundle adjustment. With this structural information, the depth maps of these images can be calculated. Next, we update the image queue by deleting some of the old images and inserting some new images into the queue, and a structural calculation of all the images can be performed by repeating the previous steps. Finally, a dense 3D point cloud can be obtained using the depth-map fusion method. The experimental results indicate that when the texture of the images is complex and the number of images exceeds 100, the proposed method can improve the calculation speed by more than a factor of four with almost no loss of precision. Furthermore, as the number of images increases, the improvement in the calculation speed will become more noticeable.

  1. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.D. [Univ. of British Columbia, Vancouver Hospital and Helath Services Centre, Dept. of Radiology, Vancouver, British Columbia (Canada)]. E-mail: schang@vanhosp.bc.ca; Cooperberg, P.L.; Wong, A.D. [Univ. of British Columbia, St. Paul' s Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Llewellyn, P.A. [Lion' s Gate Hospital, Dept. of Radiology, North Vancouver, British Columbia (Canada); Bilbey, J.H. [Royal Inland Hospital, Dept. of Radiology, Kamloops, British Columbia (Canada)

    2004-04-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT{sub 1}-weighted localizer and a fast spin-echoT{sub 2}-weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT{sub 2}-weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  2. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    International Nuclear Information System (INIS)

    Chang, S.D.; Cooperberg, P.L.; Wong, A.D.; Llewellyn, P.A.; Bilbey, J.H.

    2004-01-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT 1 -weighted localizer and a fast spin-echoT 2 -weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT 2 -weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  3. Retrospective comparison of three-dimensional imaging sequences in the visualization of posterior fossa cranial nerves.

    Science.gov (United States)

    Ors, Suna; Inci, Ercan; Turkay, Rustu; Kokurcan, Atilla; Hocaoglu, Elif

    2017-12-01

    To compare efficancy of three-dimentional SPACE (sampling perfection with application-optimized contrasts using different flip-angle evolutions) and CISS (constructive interference in steady state) sequences in the imaging of the cisternal segments of cranial nerves V-XII. Temporal MRI scans from 50 patients (F:M ratio, 27:23; mean age, 44.5±15.9 years) admitted to our hospital with vertigo, tinnitus, and hearing loss were retrospectively analyzed. All patients had both CISS and SPACE sequences. Quantitative analysis of SPACE and CISS sequences was performed by measuring the ventricle-to-parenchyma contrast-to-noise ratio (CNR). Qualitative analysis of differences in visualization capability, image quality, and severity of artifacts was also conducted. A score ranging 'no artefact' to 'severe artefacts and unreadable' was used for the assessment of artifacts and from 'not visualized' to 'completely visualized' for the assesment of image quality, respectively. The distribution of variables was controlled by the Kolmogorov-Smirnov test. Samples t-test and McNemar's test were used to determine statistical significance. Rates of visualization of posterior fossa cranial nerves in cases of complete visualization were as follows: nerve V (100% for both sequences), nerve VI (94% in SPACE, 86% in CISS sequences), nerves VII-VIII (100% for both sequences), IX-XI nerve complex (96%, 88%); nerve XII (58%, 46%) (p<0.05). SPACE sequences showed fewer artifacts than CISS sequences (p<0.002). Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Mycobacterium malmesburyense sp. nov., a non-tuberculous species of the genus Mycobacterium revealed by multiple gene sequence characterization

    CSIR Research Space (South Africa)

    Gcebe, N

    2017-04-01

    Full Text Available Journal of Systematic and Evolutionary Microbiology: DOI 10.1099/ijsem.0.001678 Mycobacterium malmesburyense sp. nov., a non-tuberculous species of the genus Mycobacterium revealed by multiple gene sequence characterization Gcebe N Rutten V Gey...

  5. Phylogeny and evolutionary histories of Pyrus L. revealed by phylogenetic trees and networks based on data from multiple DNA sequences

    Science.gov (United States)

    Reconstructing the phylogeny of Pyrus has been difficult due to the wide distribution of the genus and lack of informative data. In this study, we collected 110 accessions representing 25 Pyrus species and constructed both phylogenetic trees and phylogenetic networks based on multiple DNA sequence d...

  6. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  7. Multiple Voices, Multiple Realities: Self-Defined Images of Self among Adolescent Hispanic English Language Learners

    Science.gov (United States)

    Ajayi, Lasisi J.

    2006-01-01

    Acquisition of multiple identities to negotiate new forms of social participation and the concomitant attendant multiple languages and multiple cultures is "sine qua non" to success in English language learning classrooms. This study therefore, investigates how middle school Hispanic students reconceptualize their identities to negotiate…

  8. Molecular diagnostics of a single drug-resistant multiple myeloma case using targeted next-generation sequencing

    Directory of Open Access Journals (Sweden)

    Ikeda H

    2015-10-01

    Full Text Available Hiroshi Ikeda,1 Kazuya Ishiguro,1 Tetsuyuki Igarashi,1 Yuka Aoki,1 Toshiaki Hayashi,1 Tadao Ishida,1 Yasushi Sasaki,1,2 Takashi Tokino,2 Yasuhisa Shinomura1 1Department of Gastroenterology, Rheumatology and Clinical Immunology, 2Medical Genome Sciences, Research Institute for Frontier Medicine, Sapporo Medical University, Sapporo, Japan Abstract: A 69-year-old man was diagnosed with IgG λ-type multiple myeloma (MM, Stage II in October 2010. He was treated with one cycle of high-dose dexamethasone. After three cycles of bortezomib, the patient exhibited slow elevations in the free light-chain levels and developed a significant new increase of serum M protein. Bone marrow cytogenetic analysis revealed a complex karyotype characteristic of malignant plasma cells. To better understand the molecular pathogenesis of this patient, we sequenced for mutations in the entire coding regions of 409 cancer-related genes using a semiconductor-based sequencing platform. Sequencing analysis revealed eight nonsynonymous somatic mutations in addition to several copy number variants, including CCND1 and RB1. These alterations may play roles in the pathobiology of this disease. This targeted next-generation sequencing can allow for the prediction of drug resistance and facilitate improvements in the treatment of MM patients. Keywords: multiple myeloma, drug resistance, genome-wide sequencing, semiconductor sequencer, target therapy

  9. Frequency-locked pulse sequencer for high-frame-rate monochromatic tissue motion imaging.

    Science.gov (United States)

    Azar, Reza Zahiri; Baghani, Ali; Salcudean, Septimiu E; Rohling, Robert

    2011-04-01

    To overcome the inherent low frame rate of conventional ultrasound, we have previously presented a system that can be implemented on conventional ultrasound scanners for high-frame-rate imaging of monochromatic tissue motion. The system employs a sector subdivision technique in the sequencer to increase the acquisition rate. To eliminate the delays introduced during data acquisition, a motion phase correction algorithm has also been introduced to create in-phase displacement images. Previous experimental results from tissue- mimicking phantoms showed that the system can achieve effective frame rates of up to a few kilohertz on conventional ultrasound systems. In this short communication, we present a new pulse sequencing strategy that facilitates high-frame-rate imaging of monochromatic motion such that the acquired echo signals are inherently in-phase. The sequencer uses the knowledge of the excitation frequency to synchronize the acquisition of the entire imaging plane to that of an external exciter. This sequencing approach eliminates any need for synchronization or phase correction and has applications in tissue elastography, which we demonstrate with tissue-mimicking phantoms. © 2011 IEEE

  10. No Reference Prediction of Quality Metrics for H.264 Compressed Infrared Image Sequences for UAV Applications

    DEFF Research Database (Denmark)

    Hossain, Kabir; Mantel, Claire; Forchhammer, Søren

    2018-01-01

    The framework for this research work is the acquisition of Infrared (IR) images from Unmanned Aerial Vehicles (UAV). In this paper we consider the No-Reference (NR) prediction of Full Reference Quality Metrics for Infrared (IR) video sequences which are compressed and thus distorted by an H.264...

  11. A generative Bezier curve model for surf-zone tracking in coastal image sequences

    CSIR Research Space (South Africa)

    Burke, Michael G

    2017-09-01

    Full Text Available This work introduces a generative Bezier curve model suitable for surf-zone curve tracking in coastal image sequences. The model combines an adaptive curve parametrised by control points governed by local random walks with a global sinusoidal motion...

  12. Diffusion tensor imaging. Theory, sequence optimization and application in Alzheimer's disease

    International Nuclear Information System (INIS)

    Stieltjes, B.; Schlueter, M.; Hahn, H.K.; Wilhelm, T.; Essig, M.

    2003-01-01

    Diffusion tensor imaging (DTI) offers an in vivo view into the microarchitecture of the brain. Furthermore it allows a three-dimensional reconstruction of fiber tracts. We will discuss the principles of DTI and possibilities for sequence optimization. Finally we will give an overview of DTI and its application in Alzheimer's disease. (orig.) [de

  13. Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Choi, Dongil; Lim, Jae Hoon; Lee, Won Jae; Jang, Hyun Jung; Lim, Kyo Keun; Lee, Soon Jin; Cho, Jae Min; Kim, Seung Kwon; Kim, Gab Chul

    2002-01-01

    To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of 15 μmol/Kg was slowly infused intravenously, and axial images of seven sequences were obtained 30 minutes after the end of infusion. The MR protocol included fast spin-echo (FSE) with two echo times (TR3333-8571/TE18 and 90-117), singleshot FSE (SSFSE) with two echo times (TR∞/TE39 and 98), T2-weighted gradient-recalled acquisition in the steady state (GRASS) (TR216/TE20), T2-weighted fast multiplanar GRASS (FMPGR) (TR130/TE8.4-9.5), and T2-weighted fast multiplanar spoiled GRASS (FMPSPGR) (TR130/TE8.4-9.5). Contrast-to-noise ratios (CNRs) of HCCs determined during the imaging sequences formed the basis of quantitative analysis, and images were qualitatively assessed in terms of lesion conspicuity and image artifacts. The diagnostic accuracy of all sequences was assessed using receiver operating characteristic (ROC) analysis. Quantitative analysis revealed that the CNRs of T2-weighted FMPGR and T2-weighted FMPSPGR were significantly higher than those of the other sequences, while qualitative analysis showed that image artifacts were prominent at T2-weighted GRASS imaging. Lesion conspicuity was statistically significantly less clear at SSFSE imaging. In term of lesion detection, T-weighted FMPGR, T2- weighted FMPSPGR, and proton density FSE imaging were statistically superior to the others. T2-weighted FMPGR, T2- weighted FMPSPGR, and proton density FSE appear to be the optimal pulse sequences for ferumoxidesenhanced MR imaging in the detection of HCCs

  14. Surface coil imaging of the spine using fast sequences: Improvement of intensity profile and contrast behavior

    International Nuclear Information System (INIS)

    Requardt, H.; Deimling, M.; Weber, H.

    1986-01-01

    Sagittal and axial images obtained using a surface coil suffer from the extreme intensity profile caused by physical properties of the coil and the anatomic entity of subcutaneous fat. The authors present a measuring device that reduces these disadvantages by means of Helmholtz-type coils, and sequences that reduce the fat signal by dephasing its signal part. The extremely short repetition time (<30 msec) allows acquisition times shorter than 10 sec. Breath-holding for this short period to avoid movement artifacts is possible. Images are presented that illustrate the enhanced contrast of spinal tissue and surrounding structures. Comparisons are made with spin-echo and CHESS images

  15. Water imaging (hydrography) in the fetus: the value of a heavily T2-weighted sequence

    Energy Technology Data Exchange (ETDEWEB)

    Kline-Fath, Beth M.; Calvo-Garcia, Maria A.; O' Hara, Sara M.; Racadio, Judy M. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2007-02-15

    Since the development of fast imaging sequences, MR has proved to be a helpful tool in the evaluation of fetal pathology. Because of the high water content of fetal tissues and pathology, hydrography imaging (MR fetography) can provide additional diagnostic information. To demonstrate the benefit of MR fetography in fetal imaging. From 2004 to 2005, 126 fetal MR examinations were performed for evaluation of an abnormality depicted on an antenatal sonogram. Single-shot fast spin-echo MR imaging and MR fetography were performed through the area of fetal pathology. The two studies were retrospectively compared. The primary diagnosis was not changed with the addition of MR fetography. New findings, particularly in the kidneys and spine, were identified in 9% of the patients. When fetal pathology was of high water content (80% patients), the MR fetography imaging increased diagnostic confidence. In 11% of the patients, those with cardiovascular or low water pathology, the MR fetography was not beneficial. The mainstay of fetal imaging is currently the HASTE and SSFSE sequences. However, MR fetography is an excellent adjunct that highlights fetal pathology by reinforcing the diagnosis, identifying additional findings, and providing high-contrast high-resolution images that are helpful when counseling clinicians and patients. (orig.)

  16. Common crus aplasia: diagnosis by 3D volume rendering imaging using 3DFT-CISS sequence

    International Nuclear Information System (INIS)

    Kim, H.J.; Song, J.W.; Chon, K.-M.; Goh, E.-K.

    2004-01-01

    AIM: The purpose of this study was to evaluate the findings of three-dimensional (3D) volume rendering (VR) imaging in common crus aplasia (CCA) of the inner ear. MATERIALS AND METHODS: Using 3D VR imaging of temporal bone constructive interference in steady state (CISS) magnetic resonance (MR) images, we retrospectively reviewed seven inner ears of six children who were candidates for cochlear implants and who had been diagnosed with CCA. As controls, we used the same method to examine 402 inner ears of 201 patients who had no clinical symptoms or signs of sensorineural hearing loss. Temporal bone MR imaging (MRI) was performed with a 1.5 T MR machine using a CISS sequence, and VR of the inner ear was performed on a work station. Morphological image analysis was performed on rotation views of 3D VR images. RESULTS: In all seven cases, CCA was diagnosed by the absence of the common crus. The remaining superior semicircular canal (SCC) was normal in five and hypoplastic in two inner ears, while the posterior SCC was normal in all seven. One patient showed bilateral symmetrical CCA. Complicated combined anomalies were seen in the cochlea, vestibule and lateral SCC. CONCLUSION: 3D VR imaging findings with MR CISS sequence can directly diagnose CCA. This technique may be useful in delineating detailed anomalies of SCCs

  17. Genome sequences of rare, uncultured bacteria obtained by differential coverage binning of multiple metagenomes

    DEFF Research Database (Denmark)

    Albertsen, Mads; Hugenholtz, Philip; Skarshewski, Adam

    2013-01-01

    Reference genomes are required to understand the diverse roles of microorganisms in ecology, evolution, human and animal health, but most species remain uncultured. Here we present a sequence composition–independent approach to recover high-quality microbial genomes from deeply sequenced metageno......Reference genomes are required to understand the diverse roles of microorganisms in ecology, evolution, human and animal health, but most species remain uncultured. Here we present a sequence composition–independent approach to recover high-quality microbial genomes from deeply sequenced...

  18. Longitudinal follow-up with MR imaging and Gd-DTPA to assess the evolution of multiple sclerosis

    International Nuclear Information System (INIS)

    Berry, I.; Manelfe, C.; Bensemhoun, C.; Mekies, C.; Clanet, M.

    1990-01-01

    This paper assesses whether the changes seen on longitudinal follow-up with Gd-DTPA-enhanced MR imaging can help in evaluating the prognosis of multiple sclerosis (MS). Thirty patients with definite MS (relapsing-remitting in 22, progressive-chronic in eight) underwent 54 MR studies performed during disease evolution (21 relapses prior to steroid treatment, eight chronic progressions) and stability (n = 25). Another group of seven patients underwent repetitive MR imaging every 3 months (eight to 10 controls) and also during relapses. MR imaging was performed at 0.5 T with T1- and T2-weighted sequences; Gd-DTPA was injected intravenously (0.1 mmol/kg)

  19. Extracting a Good Quality Frontal Face Image from a Low-Resolution Video Sequence

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.

    2011-01-01

    Feeding low-resolution and low-quality images, from inexpensive surveillance cameras, to systems like, e.g., face recognition, produces erroneous and unstable results. Therefore, there is a need for a mechanism to bridge the gap between on one hand low-resolution and low-quality images......, we use a learning-based super-resolution algorithm applied to the result of the reconstruction-based part to improve the quality by another factor of two. This results in an improvement factor of four for the entire system. The proposed system has been tested on 122 low-resolution sequences from two...... different databases. The experimental results show that the proposed system can indeed produce a high-resolution and good quality frontal face image from low-resolution video sequences....

  20. Positron annihilation imaging device using multiple offset rings of detectors

    International Nuclear Information System (INIS)

    Thompson, C.J.

    1981-01-01

    This patent application relates to a positron annihilation imaging device comprising two or more coaxial circular arrays of detectors (2,2'), with the detectors in one array angularly offset with respect to the detectors in the adjacent array to detect more than one tomographic image simultaneously through different cross-sections of a patient. (author)

  1. Magnetic resonance imaging of anterior cruciate ligament of the knee: a comparison of four sequences

    International Nuclear Information System (INIS)

    Casillas, C.; Marti-Bonmati, L.; Molla, E.; Ferrer, P.; Dosda, R.

    1999-01-01

    To compare the diagnostic efficacy of the four magnetic resonance imaging (MRI) sequences that compose the standard protocol for the study of the knee in our center when employed in the examination of anterior cruciate ligament (ACL). A prospective study was carried out based on MRI findings in the knees of 326 consecutive patients. Sagittal [proton density (PD w eighted turbo-spin-echo and T2*-weighted gradient echo], coronal (PD-weighted turbo-spin-echo with fat suppression) and transverse (T2*-weighted gradient echo with magnetization transfer) images were evaluated. Each sequence was analyzed independently by two radiologists, while another two assessed all the sequences together with the clinical findings. Four categories were established: normal ACL, partially torn, completely torn and synovialized. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) with respect to the definitive diagnosis were calculated for each sequence. The statistical analysis of the findings for each category was done using the chi-squared test and the Kappa test was employed to assess the degree of agreement. According to the final diagnosis, 263 ACL were normal, 29 were partially torn, 33 were completely torn and there was 1 case of synovialization associated with a completely torn ACL. The relationship between the analysis of the ACL according to each sequence and the definitive diagnosis was very significant (p<0.001) and the agreement was excellent. All the sequences presented similar levels of diagnostic precision. The coronal sequence had least number of diagnostic errors (2.1%). The combinations of imaging techniques that resulted in the lowest error rate with respect to the definitive diagnosis were coronal PD-weighted turbo-spin-echo with fat suppression and sagittal PD-weighted turbo-spin-echo. Coronal images are highly precise in the evaluation of ACL. Sagittal sequences are the most valid for diagnosis of torn ACL. Transverse

  2. Multiple-image encryption via lifting wavelet transform and XOR operation based on compressive ghost imaging scheme

    Science.gov (United States)

    Li, Xianye; Meng, Xiangfeng; Yang, Xiulun; Wang, Yurong; Yin, Yongkai; Peng, Xiang; He, Wenqi; Dong, Guoyan; Chen, Hongyi

    2018-03-01

    A multiple-image encryption method via lifting wavelet transform (LWT) and XOR operation is proposed, which is based on a row scanning compressive ghost imaging scheme. In the encryption process, the scrambling operation is implemented for the sparse images transformed by LWT, then the XOR operation is performed on the scrambled images, and the resulting XOR images are compressed in the row scanning compressive ghost imaging, through which the ciphertext images can be detected by bucket detector arrays. During decryption, the participant who possesses his/her correct key-group, can successfully reconstruct the corresponding plaintext image by measurement key regeneration, compression algorithm reconstruction, XOR operation, sparse images recovery, and inverse LWT (iLWT). Theoretical analysis and numerical simulations validate the feasibility of the proposed method.

  3. Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Piotr [Oslo University Hospital, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Institute of Clinical Medicine, Faculty of Medicine, Oslo (Norway); Owren Nygaard, Gro [Oslo University Hospital, Department of Neurology, Oslo (Norway); Bjoernerud, Atle [Intervention Center, Oslo University Hospital, Oslo (Norway); University of Oslo, Department of Physics, Oslo (Norway); Gulowsen Celius, Elisabeth [Oslo University Hospital, Department of Neurology, Oslo (Norway); University of Oslo, Institute of Health and Society, Faculty of Medicine, Oslo (Norway); Flinstad Harbo, Hanne [University of Oslo, Institute of Clinical Medicine, Faculty of Medicine, Oslo (Norway); Oslo University Hospital, Department of Neurology, Oslo (Norway); Kristiansen Beyer, Mona [Oslo University Hospital, Department of Radiology and Nuclear Medicine, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Department of Life Sciences and Health, Oslo (Norway)

    2017-07-15

    The utility of perfusion-weighted imaging in multiple sclerosis (MS) is not well investigated. The purpose of this study was to compare baseline normalized perfusion measures in subgroups of newly diagnosed MS patients. We wanted to test the hypothesis that this method can differentiate between groups defined according to disease severity and disease activity at 1 year follow-up. Baseline magnetic resonance imaging (MRI) including a dynamic susceptibility contrast perfusion sequence was performed on a 1.5-T scanner in 66 patients newly diagnosed with relapsing-remitting MS. From the baseline MRI, cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were generated. Normalized (n) perfusion values were calculated by dividing each perfusion parameter obtained in white matter lesions by the same parameter obtained in normal-appearing white matter. Neurological examination was performed at baseline and at follow-up approximately 1 year later to establish the multiple sclerosis severity score (MSSS) and evidence of disease activity (EDA). Baseline normalized mean transit time (nMTT) was lower in patients with MSSS >3.79 (p = 0.016), in patients with EDA (p = 0.041), and in patients with both MSSS >3.79 and EDA (p = 0.032) at 1-year follow-up. Baseline normalized cerebral blood flow and normalized cerebral blood volume did not differ between these groups. Lower baseline nMTT was associated with higher disease severity and with presence of disease activity 1 year later in newly diagnosed MS patients. Further longitudinal studies are needed to confirm whether baseline-normalized perfusion measures can differentiate between disease severity and disease activity subgroups over time. (orig.)

  4. Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis

    International Nuclear Information System (INIS)

    Sowa, Piotr; Owren Nygaard, Gro; Bjoernerud, Atle; Gulowsen Celius, Elisabeth; Flinstad Harbo, Hanne; Kristiansen Beyer, Mona

    2017-01-01

    The utility of perfusion-weighted imaging in multiple sclerosis (MS) is not well investigated. The purpose of this study was to compare baseline normalized perfusion measures in subgroups of newly diagnosed MS patients. We wanted to test the hypothesis that this method can differentiate between groups defined according to disease severity and disease activity at 1 year follow-up. Baseline magnetic resonance imaging (MRI) including a dynamic susceptibility contrast perfusion sequence was performed on a 1.5-T scanner in 66 patients newly diagnosed with relapsing-remitting MS. From the baseline MRI, cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were generated. Normalized (n) perfusion values were calculated by dividing each perfusion parameter obtained in white matter lesions by the same parameter obtained in normal-appearing white matter. Neurological examination was performed at baseline and at follow-up approximately 1 year later to establish the multiple sclerosis severity score (MSSS) and evidence of disease activity (EDA). Baseline normalized mean transit time (nMTT) was lower in patients with MSSS >3.79 (p = 0.016), in patients with EDA (p = 0.041), and in patients with both MSSS >3.79 and EDA (p = 0.032) at 1-year follow-up. Baseline normalized cerebral blood flow and normalized cerebral blood volume did not differ between these groups. Lower baseline nMTT was associated with higher disease severity and with presence of disease activity 1 year later in newly diagnosed MS patients. Further longitudinal studies are needed to confirm whether baseline-normalized perfusion measures can differentiate between disease severity and disease activity subgroups over time. (orig.)

  5. Examination of self-navigating MR-sequences for perfusion imaging of the kidneys; Untersuchung von selbstnavigierenden MR-Sequenzen fuer die Perfusionsbildgebung der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Lietzmann, Florian; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ. Medizinische Fakultaet Mannheim (Germany). Computerunterstuetzte Klinische Medizin; Michaely, Henrik J. [Heidelberg Univ. Medizinische Fakultaet Mannheim (Germany). Inst. fuer Klinische Radiologie und Nuklearmedizin

    2010-07-01

    Due to the worldwide increasing number of cases of chronic kidney diseases renal imaging - as a non-invasive technique in magnetic resonance imaging - has become a very important tool for an early diagnosis of probable insufficiencies and malfunction. Especially, dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides a technique to derive physiological parameters like renal blood flow or glomerular filtration rate. Similar to the entire field of abdominal imaging, the major problems are motion artifacts that primarily arise from the patient's respiration. The self-navigating BLADE-sequence with a post processing motion correction is an approach that does not require breath holding and is therefore also easily applicable to patients who are not able to undergo multiple breath hold examinations. In this work, a T1-weighted BLADE-sequence was optimized to demonstrate the feasibility of this technique to perfusion imaging. The number of phase-encoding lines of one BLADE has a direct impact on the reduction of motion artifacts. In comparison to standard DCE-MRI sequences, the developed BLADE-sequence with optimized number of phase encoding lines could significantly reduce motion artifacts. A quantitative analysis revealed that up to a 50% displacement of the kidneys could be corrected. Therefore, it was demonstrated that dynamic motion corrected measurements without the need of a breath hold-technique are feasible. (orig.)

  6. Short term reproducibility of a high contrast 3-D isotropic optic nerve imaging sequence in healthy controls

    Science.gov (United States)

    Harrigan, Robert L.; Smith, Alex K.; Mawn, Louise A.; Smith, Seth A.; Landman, Bennett A.

    2016-03-01

    The optic nerve (ON) plays a crucial role in human vision transporting all visual information from the retina to the brain for higher order processing. There are many diseases that affect the ON structure such as optic neuritis, anterior ischemic optic neuropathy and multiple sclerosis. Because the ON is the sole pathway for visual information from the retina to areas of higher level processing, measures of ON damage have been shown to correlate well with visual deficits. Increased intracranial pressure has been shown to correlate with the size of the cerebrospinal fluid (CSF) surrounding the ON. These measures are generally taken at an arbitrary point along the nerve and do not account for changes along the length of the ON. We propose a high contrast and high-resolution 3-D acquired isotropic imaging sequence optimized for ON imaging. We have acquired scan-rescan data using the optimized sequence and a current standard of care protocol for 10 subjects. We show that this sequence has superior contrast-to-noise ratio to the current standard of care while achieving a factor of 11 higher resolution. We apply a previously published automatic pipeline to segment the ON and CSF sheath and measure the size of each individually. We show that these measures of ON size have lower short- term reproducibility than the population variance and the variability along the length of the nerve. We find that the proposed imaging protocol is (1) useful in detecting population differences and local changes and (2) a promising tool for investigating biomarkers related to structural changes of the ON.

  7. Robust skull stripping using multiple MR image contrasts insensitive to pathology.

    Science.gov (United States)

    Roy, Snehashis; Butman, John A; Pham, Dzung L

    2017-02-01

    Automatic skull-stripping or brain extraction of magnetic resonance (MR) images is often a fundamental step in many neuroimage processing pipelines. The accuracy of subsequent image processing relies on the accuracy of the skull-stripping. Although many automated stripping methods have been proposed in the past, it is still an active area of research particularly in the context of brain pathology. Most stripping methods are validated on T 1 -w MR images of normal brains, especially because high resolution T 1 -w sequences are widely acquired and ground truth manual brain mask segmentations are publicly available for normal brains. However, different MR acquisition protocols can provide complementary information about the brain tissues, which can be exploited for better distinction between brain, cerebrospinal fluid, and unwanted tissues such as skull, dura, marrow, or fat. This is especially true in the presence of pathology, where hemorrhages or other types of lesions can have similar intensities as skull in a T 1 -w image. In this paper, we propose a sparse patch based Multi-cONtrast brain STRipping method (MONSTR), 2 where non-local patch information from one or more atlases, which contain multiple MR sequences and reference delineations of brain masks, are combined to generate a target brain mask. We compared MONSTR with four state-of-the-art, publicly available methods: BEaST, SPECTRE, ROBEX, and OptiBET. We evaluated the performance of these methods on 6 datasets consisting of both healthy subjects and patients with various pathologies. Three datasets (ADNI, MRBrainS, NAMIC) are publicly available, consisting of 44 healthy volunteers and 10 patients with schizophrenia. Other three in-house datasets, comprising 87 subjects in total, consisted of patients with mild to severe traumatic brain injury, brain tumors, and various movement disorders. A combination of T 1 -w, T 2 -w were used to skull-strip these datasets. We show significant improvement in stripping

  8. A 135-kilodalton surface antigen of Mycoplasma hominis PG21 contains multiple directly repeated sequences

    DEFF Research Database (Denmark)

    Ladefoged, Søren; Birkelund, Svend; Hauge, S

    1995-01-01

    gene was sequenced, and its gene product was characterized with the goal of elucidating the structure and function of Lmp1. A total of 7,196 bp in the lmp1 region was sequenced. An open reading frame of 4,032 bp, encoding a protein of 1,344 amino acids with a calculated molecular weight of 147...

  9. Multiple Teaching Approaches, Teaching Sequence and Concept Retention in High School Physics Education

    Science.gov (United States)

    Fogarty, Ian; Geelan, David

    2013-01-01

    Students in 4 Canadian high school physics classes completed instructional sequences in two key physics topics related to motion--Straight Line Motion and Newton's First Law. Different sequences of laboratory investigation, teacher explanation (lecture) and the use of computer-based scientific visualizations (animations and simulations) were…

  10. Magnetic resonance imaging correlates of bee sting induced multiple organ dysfunction syndrome: A case report.

    Science.gov (United States)

    Das, Sushant K; Zeng, Li-Chuan; Li, Bing; Niu, Xiang-Ke; Wang, Jing-Liang; Bhetuwal, Anup; Yang, Han-Feng

    2014-09-28

    Occasionally systemic complications with high risk of death, such as multiple organ dysfunction syndrome (MODS), can occur following multiple bee stings. This case study reports a patient who presented with MODS, i.e., acute kidney injury, hepatic and cardiac dysfunction, after multiple bee stings. The standard clinical findings were then correlated with magnetic resonance imaging (MRI) findings, which demonstrates that MRI may be utilized as a simpler tool to use than other multiple diagnostics.

  11. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

  12. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    International Nuclear Information System (INIS)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung

    1997-01-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity

  13. Multiple-image hiding using super resolution reconstruction in high-frequency domains

    Science.gov (United States)

    Li, Xiao-Wei; Zhao, Wu-Xiang; Wang, Jun; Wang, Qiong-Hua

    2017-12-01

    In this paper, a robust multiple-image hiding method using the computer-generated integral imaging and the modified super-resolution reconstruction algorithm is proposed. In our work, the host image is first transformed into frequency domains by cellular automata (CA), to assure the quality of the stego-image, the secret images are embedded into the CA high-frequency domains. The proposed method has the following advantages: (1) robustness to geometric attacks because of the memory-distributed property of elemental images, (2) increasing quality of the reconstructed secret images as the scheme utilizes the modified super-resolution reconstruction algorithm. The simulation results show that the proposed multiple-image hiding method outperforms other similar hiding methods and is robust to some geometric attacks, e.g., Gaussian noise and JPEG compression attacks.

  14. Image analysis of multiple moving wood pieces in real time

    Science.gov (United States)

    Wang, Weixing

    2006-02-01

    This paper presents algorithms for image processing and image analysis of wood piece materials. The algorithms were designed for auto-detection of wood piece materials on a moving conveyor belt or a truck. When wood objects on moving, the hard task is to trace the contours of the objects in n optimal way. To make the algorithms work efficiently in the plant, a flexible online system was designed and developed, which mainly consists of image acquisition, image processing, object delineation and analysis. A number of newly-developed algorithms can delineate wood objects with high accuracy and high speed, and in the wood piece analysis part, each wood piece can be characterized by a number of visual parameters which can also be used for constructing experimental models directly in the system.

  15. Examination of cognitive fatigue in multiple sclerosis using functional magnetic resonance imaging and diffusion tensor imaging.

    Science.gov (United States)

    Genova, Helen M; Rajagopalan, Venkateswaran; Deluca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn

    2013-01-01

    The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS), looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with "state" fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI) was used to examine where in the brain white matter damage correlated with increased "trait" fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS) completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a "fatigue-network" in MS.

  16. Examination of cognitive fatigue in multiple sclerosis using functional magnetic resonance imaging and diffusion tensor imaging.

    Directory of Open Access Journals (Sweden)

    Helen M Genova

    Full Text Available The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS, looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI was used to examine where in the brain BOLD activity covaried with "state" fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI was used to examine where in the brain white matter damage correlated with increased "trait" fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a "fatigue-network" in MS.

  17. Optical multiple-image encryption based on multiplane phase retrieval and interference

    International Nuclear Information System (INIS)

    Chen, Wen; Chen, Xudong

    2011-01-01

    In this paper, we propose a new method for optical multiple-image encryption based on multiplane phase retrieval and interference. An optical encoding system is developed in the Fresnel domain. A phase-only map is iteratively extracted based on a multiplane phase retrieval algorithm, and multiple plaintexts are simultaneously encrypted. Subsequently, the extracted phase-only map is further encrypted into two phase-only masks based on a non-iterative interference algorithm. During image decryption, the advantages and security of the proposed optical cryptosystem are analyzed. Numerical results are presented to demonstrate the validity of the proposed optical multiple-image encryption method

  18. RECOGNITION OF DRAINAGE TUNNELS DURING GLACIER LAKE OUTBURST EVENTS FROM TERRESTRIAL IMAGE SEQUENCES

    Directory of Open Access Journals (Sweden)

    E. Schwalbe

    2016-06-01

    Full Text Available In recent years, many glaciers all over the world have been distinctly retreating and thinning. One of the consequences of this is the increase of so called glacier lake outburst flood events (GLOFs. The mechanisms ruling such GLOF events are still not yet fully understood by glaciologists. Thus, there is a demand for data and measurements that can help to understand and model the phenomena. Thereby, a main issue is to obtain information about the location and formation of subglacial channels through which some lakes, dammed by a glacier, start to drain. The paper will show how photogrammetric image sequence analysis can be used to collect such data. For the purpose of detecting a subglacial tunnel, a camera has been installed in a pilot study to observe the area of the Colonia Glacier (Northern Patagonian Ice Field where it dams the Lake Cachet II. To verify the hypothesis, that the course of the subglacial tunnel is indicated by irregular surface motion patterns during its collapse, the camera acquired image sequences of the glacier surface during several GLOF events. Applying tracking techniques to these image sequences, surface feature motion trajectories could be obtained for a dense raster of glacier points. Since only a single camera has been used for image sequence acquisition, depth information is required to scale the trajectories. Thus, for scaling and georeferencing of the measurements a GPS-supported photogrammetric network has been measured. The obtained motion fields of the Colonia Glacier deliver information about the glacier’s behaviour before during and after a GLOF event. If the daily vertical glacier motion of the glacier is integrated over a period of several days and projected into a satellite image, the location and shape of the drainage channel underneath the glacier becomes visible. The high temporal resolution of the motion fields may also allows for an analysis of the tunnels dynamic in comparison to the changing

  19. Magnetic nanoparticle imaging by random and maximum length sequences of inhomogeneous activation fields.

    Science.gov (United States)

    Baumgarten, Daniel; Eichardt, Roland; Crevecoeur, Guillaume; Supriyanto, Eko; Haueisen, Jens

    2013-01-01

    Biomedical applications of magnetic nanoparticles require a precise knowledge of their biodistribution. From multi-channel magnetorelaxometry measurements, this distribution can be determined by means of inverse methods. It was recently shown that the combination of sequential inhomogeneous excitation fields in these measurements is favorable regarding the reconstruction accuracy when compared to homogeneous activation . In this paper, approaches for the determination of activation sequences for these measurements are investigated. Therefor, consecutive activation of single coils, random activation patterns and families of m-sequences are examined in computer simulations involving a sample measurement setup and compared with respect to the relative condition number of the system matrix. We obtain that the values of this condition number decrease with larger number of measurement samples for all approaches. Random sequences and m-sequences reveal similar results with a significant reduction of the required number of samples. We conclude that the application of pseudo-random sequences for sequential activation in the magnetorelaxometry imaging of magnetic nanoparticles considerably reduces the number of required sequences while preserving the relevant measurement information.

  20. Source coherence impairments in a direct detection direct sequence optical code-division multiple-access system.

    Science.gov (United States)

    Fsaifes, Ihsan; Lepers, Catherine; Lourdiane, Mounia; Gallion, Philippe; Beugin, Vincent; Guignard, Philippe

    2007-02-01

    We demonstrate that direct sequence optical code- division multiple-access (DS-OCDMA) encoders and decoders using sampled fiber Bragg gratings (S-FBGs) behave as multipath interferometers. In that case, chip pulses of the prime sequence codes generated by spreading in time-coherent data pulses can result from multiple reflections in the interferometers that can superimpose within a chip time duration. We show that the autocorrelation function has to be considered as the sum of complex amplitudes of the combined chip as the laser source coherence time is much greater than the integration time of the photodetector. To reduce the sensitivity of the DS-OCDMA system to the coherence time of the laser source, we analyze the use of sparse and nonperiodic quadratic congruence and extended quadratic congruence codes.

  1. Source coherence impairments in a direct detection direct sequence optical code-division multiple-access system

    Science.gov (United States)

    Fsaifes, Ihsan; Lepers, Catherine; Lourdiane, Mounia; Gallion, Philippe; Beugin, Vincent; Guignard, Philippe

    2007-02-01

    We demonstrate that direct sequence optical code- division multiple-access (DS-OCDMA) encoders and decoders using sampled fiber Bragg gratings (S-FBGs) behave as multipath interferometers. In that case, chip pulses of the prime sequence codes generated by spreading in time-coherent data pulses can result from multiple reflections in the interferometers that can superimpose within a chip time duration. We show that the autocorrelation function has to be considered as the sum of complex amplitudes of the combined chip as the laser source coherence time is much greater than the integration time of the photodetector. To reduce the sensitivity of the DS-OCDMA system to the coherence time of the laser source, we analyze the use of sparse and nonperiodic quadratic congruence and extended quadratic congruence codes.

  2. Learning multiple variable-speed sequences in striatum via cortical tutoring.

    Science.gov (United States)

    Murray, James M; Escola, G Sean

    2017-05-08

    Sparse, sequential patterns of neural activity have been observed in numerous brain areas during timekeeping and motor sequence tasks. Inspired by such observations, we construct a model of the striatum, an all-inhibitory circuit where sequential activity patterns are prominent, addressing the following key challenges: (i) obtaining control over temporal rescaling of the sequence speed, with the ability to generalize to new speeds; (ii) facilitating flexible expression of distinct sequences via selective activation, concatenation, and recycling of specific subsequences; and (iii) enabling the biologically plausible learning of sequences, consistent with the decoupling of learning and execution suggested by lesion studies showing that cortical circuits are necessary for learning, but that subcortical circuits are sufficient to drive learned behaviors. The same mechanisms that we describe can also be applied to circuits with both excitatory and inhibitory populations, and hence may underlie general features of sequential neural activity pattern generation in the brain.

  3. Simultaneous reconstruction of multiple depth images without off-focus points in integral imaging using a graphics processing unit.

    Science.gov (United States)

    Yi, Faliu; Lee, Jieun; Moon, Inkyu

    2014-05-01

    The reconstruction of multiple depth images with a ray back-propagation algorithm in three-dimensional (3D) computational integral imaging is computationally burdensome. Further, a reconstructed depth image consists of a focus and an off-focus area. Focus areas are 3D points on the surface of an object that are located at the reconstructed depth, while off-focus areas include 3D points in free-space that do not belong to any object surface in 3D space. Generally, without being removed, the presence of an off-focus area would adversely affect the high-level analysis of a 3D object, including its classification, recognition, and tracking. Here, we use a graphics processing unit (GPU) that supports parallel processing with multiple processors to simultaneously reconstruct multiple depth images using a lookup table containing the shifted values along the x and y directions for each elemental image in a given depth range. Moreover, each 3D point on a depth image can be measured by analyzing its statistical variance with its corresponding samples, which are captured by the two-dimensional (2D) elemental images. These statistical variances can be used to classify depth image pixels as either focus or off-focus points. At this stage, the measurement of focus and off-focus points in multiple depth images is also implemented in parallel on a GPU. Our proposed method is conducted based on the assumption that there is no occlusion of the 3D object during the capture stage of the integral imaging process. Experimental results have demonstrated that this method is capable of removing off-focus points in the reconstructed depth image. The results also showed that using a GPU to remove the off-focus points could greatly improve the overall computational speed compared with using a CPU.

  4. Imaging Finding of Multiple Endocrine Neoplasia Type 1: Case Report

    International Nuclear Information System (INIS)

    Yum, Tae Jun; Cho, Hee Woo

    2012-01-01

    Multiple endocrine neoplasia type 1 (MEN1) is an autosomal dominant inherited syndrome with characteristic clinical and radiological manifestations. Many reports on MEN1 have been published; however, no cases of radiologically diagnosed MEN1 have been reported. Therefore, we report on a radiologically diagnosed case of MEN1 with clinical symptoms of gastroduodenal ulcer.

  5. MR-based conductivity imaging using multiple receiver coils.

    Science.gov (United States)

    Lee, Joonsung; Shin, Jaewook; Kim, Dong-Hyun

    2016-08-01

    To propose a signal combination method for MR-based tissue conductivity mapping using a standard clinical scanner with multiple receiver coils. The theory of the proposed method is presented with two practical approaches, a coil-specific approach and a subject-specific approach. Conductivity maps were reconstructed using the transceive phase of the combined signal. The sensitivities of the coefficients used for signal combination were analyzed and the method was compared with other signal combination methods. For validation, multiple receiver brain coils and multiple receiver breast coils were used in phantom, in vivo brain, and in vivo breast studies. The variation among the conductivity estimates was conductivity estimates. MR-based tissue conductivity mapping is feasible when using a standard clinical MR scanner with multiple receiver coils. The proposed method reduces systematic errors in phase-based conductivity mapping that can occur due to the inhomogeneous magnitude of the combined receive profile. Magn Reson Med 76:530-539, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    Science.gov (United States)

    Lasič, Samo; Lundell, Henrik; Topgaard, Daniel; Dyrby, Tim B

    2018-04-01

    To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). The effects of imaging gradients in FEXI were observed on yeast cells. To analyze the AXR bias, signal evolution was calculated by applying matrix exponential operators. A sharp threshold for the slice thickness was identified, below which the AXR is increasingly underestimated. The bias can be understood in terms of an extended low-pass diffusion filtering during the LS interval, which is more pronounced at lower exchange rates. For a total exchange rate constant larger than 1 s -1 , the AXR bias is expected to be negligible when slices thicker than 2.5 mm are used. In correlation experiments like FEXI, relying on LS with variable duration, imaging gradients may cause disrupting effects that cannot be easily mitigated and should be carefully considered for unbiased results. In typical clinical applications of FEXI, the imaging gradients are expected to cause a negligible AXR bias. However, the AXR bias may be significant in preclinical settings or whenever thin imaging slices are used. Magn Reson Med 79:2228-2235, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Multiple interpretations of a pair of images of a surface

    Science.gov (United States)

    Longuet-Higgins, H. C.

    1988-07-01

    It is known that, if two optical images of a visually textured surface, projected from finitely separated viewpoints, allow more than one three-dimensional interpretation, then the surface must be part of a quadric passing through the two viewpoints. It is here shown that this quadric is either a plane or a ruled surface of a type first considered by Maybank (1985) in a study of ambiguous optic flow fields. In the latter case, three is the maximum number of distinct interpretations that the two images can sustain.

  8. Positron annihilation imaging device using multiple offset rings of detectors

    International Nuclear Information System (INIS)

    Thompson, C.J.

    1982-01-01

    A means is provided for recording more than one tomographic image simultaneously through different cross-sections of a patient, using positron emission tomography. Separate rings of detectors are used to construct every odd-numbered slice, and coincident events that occur between adjacent rings of detectors provide a center or even-numbered slice. Detector rings are offset with respect to one another by half the angular separation of the detectors, allowing an image to be reconstructed from the central slice without the necessity of physically rotating the detector array while accumulating data

  9. Automatic registration of panoramic image sequence and mobile laser scanning data using semantic features

    Science.gov (United States)

    Li, Jianping; Yang, Bisheng; Chen, Chi; Huang, Ronggang; Dong, Zhen; Xiao, Wen

    2018-02-01

    Inaccurate exterior orientation parameters (EoPs) between sensors obtained by pre-calibration leads to failure of registration between panoramic image sequence and mobile laser scanning data. To address this challenge, this paper proposes an automatic registration method based on semantic features extracted from panoramic images and point clouds. Firstly, accurate rotation parameters between the panoramic camera and the laser scanner are estimated using GPS and IMU aided structure from motion (SfM). The initial EoPs of panoramic images are obtained at the same time. Secondly, vehicles in panoramic images are extracted by the Faster-RCNN as candidate primitives to be matched with potential corresponding primitives in point clouds according to the initial EoPs. Finally, translation between the panoramic camera and the laser scanner is refined by maximizing the overlapping area of corresponding primitive pairs based on the Particle Swarm Optimization (PSO), resulting in a finer registration between panoramic image sequences and point clouds. Two challenging urban scenes were experimented to assess the proposed method, and the final registration errors of these two scenes were both less than three pixels, which demonstrates a high level of automation, robustness and accuracy.

  10. Object-Oriented Query Language For Events Detection From Images Sequences

    Science.gov (United States)

    Ganea, Ion Eugen

    2015-09-01

    In this paper is presented a method to represent the events extracted from images sequences and the query language used for events detection. Using an object oriented model the spatial and temporal relationships between salient objects and also between events are stored and queried. This works aims to unify the storing and querying phases for video events processing. The object oriented language syntax used for events processing allow the instantiation of the indexes classes in order to improve the accuracy of the query results. The experiments were performed on images sequences provided from sport domain and it shows the reliability and the robustness of the proposed language. To extend the language will be added a specific syntax for constructing the templates for abnormal events and for detection of the incidents as the final goal of the research.

  11. Minimization of Dead-Periods in MRI Pulse Sequences for Imaging Oblique Planes

    Science.gov (United States)

    Atalar, Ergin; McVeigh, Elliot R.

    2007-01-01

    With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gradient waveforms that will be applied to the amplifiers instead of the slice, readout, and phase encoding waveforms. Because this method ensures that the gradient amplifiers will always switch at their maximum slew rate, it results in the minimum possible dead-period for given imaging parameters and scan plane position. A GRASS pulse sequence has been designed and ultra-short TR and TE values have been obtained with standard gradient amplifiers and coils. For some oblique slices, we have achieved shorter TR and TE values than those for nonoblique slices. PMID:7869900

  12. [Study on method of tracking the active cells in image sequences based on EKF-PF].

    Science.gov (United States)

    Tang, Chunming; Liu, Ying

    2013-02-01

    In cell image sequences, due to the nonlinear and nonGaussian motion characteristics of active cells, the accurate prediction and tracking is still an unsolved problem. We applied extended Kalman particle filter (EKF-PF) here in our study, attempting to solve the problem. Firstly we confirmed the existence and positions of the active cells. Then we established a motion model and improved it via adding motion angle estimation. Next we predicted motion parameters, such as displacement, velocity, accelerated velocity and motion angle, in region centers of the cells being tracked. Finally we obtained the motion traces of active cells. There were fourteen active cells in three image sequences which have been tracked. The errors were less than 2.5 pixels when the prediction values were compared with actual values. It showed that the presented algorithm may basically reach the solution of accurate predition and tracking of the active cells.

  13. Visualization and correction of automated segmentation, tracking and lineaging from 5-D stem cell image sequences.

    Science.gov (United States)

    Wait, Eric; Winter, Mark; Bjornsson, Chris; Kokovay, Erzsebet; Wang, Yue; Goderie, Susan; Temple, Sally; Cohen, Andrew R

    2014-10-03

    Neural stem cells are motile and proliferative cells that undergo mitosis, dividing to produce daughter cells and ultimately generating differentiated neurons and glia. Understanding the mechanisms controlling neural stem cell proliferation and differentiation will play a key role in the emerging fields of regenerative medicine and cancer therapeutics. Stem cell studies in vitro from 2-D image data are well established. Visualizing and analyzing large three dimensional images of intact tissue is a challenging task. It becomes more difficult as the dimensionality of the image data increases to include time and additional fluorescence channels. There is a pressing need for 5-D image analysis and visualization tools to study cellular dynamics in the intact niche and to quantify the role that environmental factors play in determining cell fate. We present an application that integrates visualization and quantitative analysis of 5-D (x,y,z,t,channel) and large montage confocal fluorescence microscopy images. The image sequences show stem cells together with blood vessels, enabling quantification of the dynamic behaviors of stem cells in relation to their vascular niche, with applications in developmental and cancer biology. Our application automatically segments, tracks, and lineages the image sequence data and then allows the user to view and edit the results of automated algorithms in a stereoscopic 3-D window while simultaneously viewing the stem cell lineage tree in a 2-D window. Using the GPU to store and render the image sequence data enables a hybrid computational approach. An inference-based approach utilizing user-provided edits to automatically correct related mistakes executes interactively on the system CPU while the GPU handles 3-D visualization tasks. By exploiting commodity computer gaming hardware, we have developed an application that can be run in the laboratory to facilitate rapid iteration through biological experiments. We combine unsupervised image

  14. Full wavefield migration: Seismic imaging using multiple scattering effects

    NARCIS (Netherlands)

    Davydenko, M.

    2016-01-01

    Seismic imaging aims at revealing the structural information of the subsurface using the reflected wavefields captured by sensors usually located at the surface. Wave propagation is a complex phenomenon and the measured data contain a set of backscattered events including not only primary

  15. Accounting for free-surface multiples in Marchenko imaging

    NARCIS (Netherlands)

    Singh, S.; Snieder, R; van der Neut, J.R.; Thorbecke, J.W.; Slob, E.C.; Wapenaar, C.P.A.

    2017-01-01

    Imagine placing a receiver at any location in the earth and recording the response at that location to sources on the surface. In such a world, we could place receivers around our reservoir to better image the reservoir and understand its properties. Realistically, this is not a feasible approach

  16. The value of MR imaging of PDFASAT sequence in the diagnosis of extremities occult fractures

    International Nuclear Information System (INIS)

    Lu Lingquan; Xu Mingshen; Wu Qianzhi; Mao Chunnan; Wang Shuzi; Zhou Xingfan; Wang Liping

    2004-01-01

    Objective: To investigate the value of MR imaging of proton density weighted-fat saturated (PDFASAT) sequence in detecting the occult fracture of extremities. Methods: Thirty-one patients with acute trauma were studied using radiography and MR imaging within 45 days. MR sequences included FSE T 1 WI, T 2 WI, and PDFASAT. 21 occult fractures occurred in the knee joint, 6 in the hip joint, 1 in the elbow joint, 2 in the shoulder, and 1 in the ankle. Results: All 31 cases had normal radiographic results. 10 cases with proximal fibula, 4 with proximal tibia and 7 with femur condyle occult fractures were found in 21 knee joint acute trauma cases. 2 cases with intertrochanteric, 2 with femoral neck and 2 with cotyle occult fractures were found in 6 hip joint trauma cases. 2 proximal humerus occult fractures were found in 2 shoulder cases. 1 distal humerus and 1 distal fibula occult fracture was found in elbow and ankle cases. MR imaging demonstrated irregular linear low signal in the subcortical region on both T 1 WI and T 2 WI, and high signal changes around low signal were seen on T 2 WI in some cases. The high signal in PDFASAT sequence was more remarkable and wider than that on both T 1 WI and T 2 WI. Conclusion: MR imaging could determine the diagnosis of acute and chronic occult fractures. MRI should be the next choice when plain films fail to reveal suspected fractures in setting of suggestive symptoms and positive physical examination. PDFASAT would be the best effective sequence among the T 1 WI, T 2 WI, and PDFASAT. (author)

  17. Fast triple-spin-echo Dixon (FTSED) sequence for water and fat imaging

    Czech Academy of Sciences Publication Activity Database

    Kořínek, Radim; Bartušek, Karel; Starčuk jr., Zenon

    2017-01-01

    Roč. 37, APR (2017), s. 164-170 ISSN 0730-725X R&D Projects: GA MŠk ED0017/01/01; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : fast triple-spin-echo Dixon * sequence * MRI * fat fraction * water-fat * ultra-high field * 9.4 T * FTSED Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Radiology, nuclear medicine and medical imaging Impact factor: 2.225, year: 2016

  18. On the Farey sequence and its augmentation for applications to image analysis

    Directory of Open Access Journals (Sweden)

    Pratihar Sanjoy

    2017-09-01

    Full Text Available We introduce a novel concept of the augmented Farey table (AFT. Its purpose is to store the ranks of fractions of a Farey sequence in an efficient manner so as to return the rank of any query fraction in constant time. As a result, computations on the digital plane can be crafted down to simple integer operations; for example, the tasks like determining the extent of collinearity of integer points or of parallelism of straight lines—often required to solve many image-analytic problems—can be made fast and efficient through an appropriate AFT-based tool. We derive certain interesting characterizations of an AFT for its efficient generation. We also show how, for a fraction not present in a Farey sequence, the rank of the nearest fraction in that sequence can efficiently be obtained by the regula falsi method from the AFT concerned. To assert its merit, we show its use in two applications—one in polygonal approximation of digital curves and the other in skew correction of engineering drawings in document images. Experimental results indicate the potential of the AFT in such image-analytic applications.

  19. Accelerating Spaceborne SAR Imaging Using Multiple CPU/GPU Deep Collaborative Computing

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2016-04-01

    Full Text Available With the development of synthetic aperture radar (SAR technologies in recent years, the huge amount of remote sensing data brings challenges for real-time imaging processing. Therefore, high performance computing (HPC methods have been presented to accelerate SAR imaging, especially the GPU based methods. In the classical GPU based imaging algorithm, GPU is employed to accelerate image processing by massive parallel computing, and CPU is only used to perform the auxiliary work such as data input/output (IO. However, the computing capability of CPU is ignored and underestimated. In this work, a new deep collaborative SAR imaging method based on multiple CPU/GPU is proposed to achieve real-time SAR imaging. Through the proposed tasks partitioning and scheduling strategy, the whole image can be generated with deep collaborative multiple CPU/GPU computing. In the part of CPU parallel imaging, the advanced vector extension (AVX method is firstly introduced into the multi-core CPU parallel method for higher efficiency. As for the GPU parallel imaging, not only the bottlenecks of memory limitation and frequent data transferring are broken, but also kinds of optimized strategies are applied, such as streaming, parallel pipeline and so on. Experimental results demonstrate that the deep CPU/GPU collaborative imaging method enhances the efficiency of SAR imaging on single-core CPU by 270 times and realizes the real-time imaging in that the imaging rate outperforms the raw data generation rate.

  20. Accelerating Spaceborne SAR Imaging Using Multiple CPU/GPU Deep Collaborative Computing.

    Science.gov (United States)

    Zhang, Fan; Li, Guojun; Li, Wei; Hu, Wei; Hu, Yuxin

    2016-04-07

    With the development of synthetic aperture radar (SAR) technologies in recent years, the huge amount of remote sensing data brings challenges for real-time imaging processing. Therefore, high performance computing (HPC) methods have been presented to accelerate SAR imaging, especially the GPU based methods. In the classical GPU based imaging algorithm, GPU is employed to accelerate image processing by massive parallel computing, and CPU is only used to perform the auxiliary work such as data input/output (IO). However, the computing capability of CPU is ignored and underestimated. In this work, a new deep collaborative SAR imaging method based on multiple CPU/GPU is proposed to achieve real-time SAR imaging. Through the proposed tasks partitioning and scheduling strategy, the whole image can be generated with deep collaborative multiple CPU/GPU computing. In the part of CPU parallel imaging, the advanced vector extension (AVX) method is firstly introduced into the multi-core CPU parallel method for higher efficiency. As for the GPU parallel imaging, not only the bottlenecks of memory limitation and frequent data transferring are broken, but also kinds of optimized strategies are applied, such as streaming, parallel pipeline and so on. Experimental results demonstrate that the deep CPU/GPU collaborative imaging method enhances the efficiency of SAR imaging on single-core CPU by 270 times and realizes the real-time imaging in that the imaging rate outperforms the raw data generation rate.

  1. Reanalysis of RNA-sequencing data reveals several additional fusion genes with multiple isoforms.

    Science.gov (United States)

    Kangaspeska, Sara; Hultsch, Susanne; Edgren, Henrik; Nicorici, Daniel; Murumägi, Astrid; Kallioniemi, Olli

    2012-01-01

    RNA-sequencing and tailored bioinformatic methodologies have paved the way for identification of expressed fusion genes from the chaotic genomes of solid tumors. We have recently successfully exploited RNA-sequencing for the discovery of 24 novel fusion genes in breast cancer. Here, we demonstrate the importance of continuous optimization of the bioinformatic methodology for this purpose, and report the discovery and experimental validation of 13 additional fusion genes from the same samples. Integration of copy number profiling with the RNA-sequencing results revealed that the majority of the gene fusions were promoter-donating events that occurred at copy number transition points or involved high-level DNA-amplifications. Sequencing of genomic fusion break points confirmed that DNA-level rearrangements underlie selected fusion transcripts. Furthermore, a significant portion (>60%) of the fusion genes were alternatively spliced. This illustrates the importance of reanalyzing sequencing data as gene definitions change and bioinformatic methods improve, and highlights the previously unforeseen isoform diversity among fusion transcripts.

  2. Reanalysis of RNA-sequencing data reveals several additional fusion genes with multiple isoforms.

    Directory of Open Access Journals (Sweden)

    Sara Kangaspeska

    Full Text Available RNA-sequencing and tailored bioinformatic methodologies have paved the way for identification of expressed fusion genes from the chaotic genomes of solid tumors. We have recently successfully exploited RNA-sequencing for the discovery of 24 novel fusion genes in breast cancer. Here, we demonstrate the importance of continuous optimization of the bioinformatic methodology for this purpose, and report the discovery and experimental validation of 13 additional fusion genes from the same samples. Integration of copy number profiling with the RNA-sequencing results revealed that the majority of the gene fusions were promoter-donating events that occurred at copy number transition points or involved high-level DNA-amplifications. Sequencing of genomic fusion break points confirmed that DNA-level rearrangements underlie selected fusion transcripts. Furthermore, a significant portion (>60% of the fusion genes were alternatively spliced. This illustrates the importance of reanalyzing sequencing data as gene definitions change and bioinformatic methods improve, and highlights the previously unforeseen isoform diversity among fusion transcripts.

  3. Imaging a Large Sample with Selective Plane Illumination Microscopy Based on Multiple Fluorescent Microsphere Tracking

    Science.gov (United States)

    Ryu, Inkeon; Kim, Daekeun

    2018-04-01

    A typical selective plane illumination microscopy (SPIM) image size is basically limited by the field of view, which is a characteristic of the objective lens. If an image larger than the imaging area of the sample is to be obtained, image stitching, which combines step-scanned images into a single panoramic image, is required. However, accurately registering the step-scanned images is very difficult because the SPIM system uses a customized sample mount where uncertainties for the translational and the rotational motions exist. In this paper, an image registration technique based on multiple fluorescent microsphere tracking is proposed in the view of quantifying the constellations and measuring the distances between at least two fluorescent microspheres embedded in the sample. Image stitching results are demonstrated for optically cleared large tissue with various staining methods. Compensation for the effect of the sample rotation that occurs during the translational motion in the sample mount is also discussed.

  4. Applicability of the 3D-VIBE sequence to whole brain imaging

    International Nuclear Information System (INIS)

    Makabe, Takeshi; Nakamura, Manami; Moriyama, Ryo

    2009-01-01

    The volumetric interpolated breath-hold examination (VIBE) method has been developed imaging also holds its breath in an abdomen, and to do three-dimensional T1WI in possible time in gradient echo sequence, and applied to dynamic study mainly and planning for time reduction using an interpolation and partial fourier. We considered the condition for imaging to do whole brain as high resolution image using VIBE. Even if base matrix was maintained when an interpolation and partial fourier were used too much excessively by Phantom experiment, the resolution of multiplanar reconstruction (MPR) image fell. There was a limit of the interpolation therefore to maintain the resolution as voxel. Signal-to-noise ratio (SNR) fell by flip angle (FA) increase by the applicability to the head, and peak existed in about 15 deg in contrast-to-noise ratio (CNR) of white matter and gray matter. Therefore by it's clinical and optimizing the imaging condition of VIBE, whole brain, it was imaging possible in about 3 minutes as high resolution image. (author)

  5. Diffusion tensor imaging using multiple coils for mouse brain connectomics.

    Science.gov (United States)

    Nouls, John C; Badea, Alexandra; Anderson, Robert B J; Cofer, Gary P; Allan Johnson, G

    2018-04-19

    The correlation between brain connectivity and psychiatric or neurological diseases has intensified efforts to develop brain connectivity mapping techniques on mouse models of human disease. The neural architecture of mouse brain specimens can be shown non-destructively and three-dimensionally by diffusion tensor imaging, which enables tractography, the establishment of a connectivity matrix and connectomics. However, experiments on cohorts of animals can be prohibitively long. To improve throughput in a 7-T preclinical scanner, we present a novel two-coil system in which each coil is shielded, placed off-isocenter along the axis of the magnet and connected to a receiver circuit of the scanner. Preservation of the quality factor of each coil is essential to signal-to-noise ratio (SNR) performance and throughput, because mouse brain specimen imaging at 7 T takes place in the coil-dominated noise regime. In that regime, we show a shielding configuration causing no SNR degradation in the two-coil system. To acquire data from several coils simultaneously, the coils are placed in the magnet bore, around the isocenter, in which gradient field distortions can bias diffusion tensor imaging metrics, affect tractography and contaminate measurements of the connectivity matrix. We quantified the experimental alterations in fractional anisotropy and eigenvector direction occurring in each coil. We showed that, when the coils were placed 12 mm away from the isocenter, measurements of the brain connectivity matrix appeared to be minimally altered by gradient field distortions. Simultaneous measurements on two mouse brain specimens demonstrated a full doubling of the diffusion tensor imaging throughput in practice. Each coil produced images devoid of shading or artifact. To further improve the throughput of mouse brain connectomics, we suggested a future expansion of the system to four coils. To better understand acceptable trade-offs between imaging throughput and connectivity

  6. Correction of over and under exposure images using multiple lighting system

    International Nuclear Information System (INIS)

    Im, Jonghoon; Fujii, Hiromitsu; Yamashita, Atsushi; Asama, Hajime

    2015-01-01

    When images are acquired in bright condition, it can cause a loss of highlight details (over exposure) in bright area and a loss of shadow details (under exposure) in dark area. Over and under exposure causes a big problem when people investigate dangerous place like Fukushima nuclear power plant through the camera attached remote control robot. In this paper, we propose a method to correct the over and under exposure image to solve the problem. The image processing consists of four steps. Firstly, multiple images are acquired by alternately turning on and off each illumination which set in different positions. Then the image obtained first is defined as input image 1, the image obtained second is defined as input image 2 and the image obtained N-th is defined as input image N. Secondly, luminance of the images is corrected. Thirdly, over and under exposure regions in the image are extracted from the input image 1. Finally, the over and under exposure regions in the input image 1 are compensated by other images. The results show that the over and under exposure regions in the input image are recovered by our proposed method. (author)

  7. Practical and Scalable Transmission of Segmented Video Sequences to Multiple Players Using H.264

    Science.gov (United States)

    Quax, Peter; di Fiore, Fabian; Issaris, Panagiotis; Lamotte, Wim; van Reeth, Frank

    We present a practical way to distribute viewports on the same video sequence to large amounts of players. Each of them has personal preferences to be met or is limited by the physical properties of his/her device (e.g., screen size of a PDA or processing power of a mobile phone). Instead of taking the naïve approach, in which sections of the video sequence are decoded and re-encoded for each of the clients, we have exploited advanced features offered by the H.264 codec to enable selection of parts of the video sequence by directly manipulating the encoder-generated bitstream. At the same time, we have overcome several practical issues presented by the fact that support for these features is sadly lacking from the state-of-the-art encoders available on the market. Two alternative solutions are discussed and have been implemented, enabling the generation of measurement results and comparison to alternative approaches.

  8. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Diffusion tensor MR imaging evaluation of the corpus callosum of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rueda, Fernanda; Domingues, Romeu Cortes; Papais-Alvarenga, Regina M.; Gasparetto, Emerson L.

    2008-01-01

    Objective: To evaluate the fractional anisotropy (FA) values of the normal-appearing white matter of the corpus callosum (CC) in patients with relapsing-remitting multiple sclerosis (MS). Method: Fifty-seven patients with diagnosis of relapsing-remitting MS and 47 age- and gender-matched controls were studied. A conventional MR imaging protocol and a DTI sequence were performed. One neuro radiologist placed the regions of interest (ROIs) in the FA maps in five different portions of the normal-appearing CC (rostrum, genu, anterior and posterior portion of the body and splenium) in all cases. The statistical analysis was performed with the Mann-Whitney U test and p<0.05 was considered statistically significant. Results: The FA values were lower in the MS patients compared with the controls (p<0.05) in the following CC regions: rostrum (0.720 vs 0.819), anterior body (0.698 vs 0.752), posterior body (0.711 vs 0.759) and splenium (0.720 vs 0.880). Conclusion: In this series, there was a robust decrease in the FA in all regions of the normal-appearing CC, being significant in the rostrum, body and splenium. This finding suggests that there is a subtle and diffuse abnormality in the CC, which could be probably related to myelin content loss, axonal damage and gliosis. (author)

  10. Population genetic analysis of shotgun assemblies of genomic sequences from multiple individuals

    DEFF Research Database (Denmark)

    Hellmann, Ines; Mang, Yuan; Gu, Zhiping

    2008-01-01

    We introduce a simple, broadly applicable method for obtaining estimates of nucleotide diversity from genomic shotgun sequencing data. The method takes into account the special nature of these data: random sampling of genomic segments from one or more individuals and a relatively high error rate...... for individual reads. Applying this method to data from the Celera human genome sequencing and SNP discovery project, we obtain estimates of nucleotide diversity in windows spanning the human genome and show that the diversity to divergence ratio is reduced in regions of low recombination. Furthermore, we show...

  11. Spinal focal lesion detection in multiple myeloma using multimodal image features

    Science.gov (United States)

    Fränzle, Andrea; Hillengass, Jens; Bendl, Rolf

    2015-03-01

    Multiple myeloma is a tumor disease in the bone marrow that affects the skeleton systemically, i.e. multiple lesions can occur in different sites in the skeleton. To quantify overall tumor mass for determining degree of disease and for analysis of therapy response, volumetry of all lesions is needed. Since the large amount of lesions in one patient impedes manual segmentation of all lesions, quantification of overall tumor volume is not possible until now. Therefore development of automatic lesion detection and segmentation methods is necessary. Since focal tumors in multiple myeloma show different characteristics in different modalities (changes in bone structure in CT images, hypointensity in T1 weighted MR images and hyperintensity in T2 weighted MR images), multimodal image analysis is necessary for the detection of focal tumors. In this paper a pattern recognition approach is presented that identifies focal lesions in lumbar vertebrae based on features from T1 and T2 weighted MR images. Image voxels within bone are classified using random forests based on plain intensities and intensity value derived features (maximum, minimum, mean, median) in a 5 x 5 neighborhood around a voxel from both T1 and T2 weighted MR images. A test data sample of lesions in 8 lumbar vertebrae from 4 multiple myeloma patients can be classified at an accuracy of 95% (using a leave-one-patient-out test). The approach provides a reasonable delineation of the example lesions. This is an important step towards automatic tumor volume quantification in multiple myeloma.

  12. Accommodating multiple illumination sources in an imaging colorimetry environment

    Science.gov (United States)

    Tobin, Kenneth W., Jr.; Goddard, James S., Jr.; Hunt, Martin A.; Hylton, Kathy W.; Karnowski, Thomas P.; Simpson, Marc L.; Richards, Roger K.; Treece, Dale A.

    2000-03-01

    Researchers at the Oak Ridge National Laboratory have been developing a method for measuring color quality in textile products using a tri-stimulus color camera system. Initial results of the Imaging Tristimulus Colorimeter (ITC) were reported during 1999. These results showed that the projection onto convex sets (POCS) approach to color estimation could be applied to complex printed patterns on textile products with high accuracy and repeatability. Image-based color sensors used for on-line measurement are not colorimetric by nature and require a non-linear transformation of the component colors based on the spectral properties of the incident illumination, imaging sensor, and the actual textile color. Our earlier work reports these results for a broad-band, smoothly varying D65 standard illuminant. To move the measurement to the on-line environment with continuously manufactured textile webs, the illumination source becomes problematic. The spectral content of these light sources varies substantially from the D65 standard illuminant and can greatly impact the measurement performance of the POCS system. Although absolute color measurements are difficult to make under different illumination, referential measurements to monitor color drift provide a useful indication of product quality. Modifications to the ITC system have been implemented to enable the study of different light sources. These results and the subsequent analysis of relative color measurements will be reported for textile products.

  13. 3D Power Line Extraction from Multiple Aerial Images

    Directory of Open Access Journals (Sweden)

    Jaehong Oh

    2017-09-01

    Full Text Available Power lines are cables that carry electrical power from a power plant to an electrical substation. They must be connected between the tower structures in such a way that ensures minimum tension and sufficient clearance from the ground. Power lines can stretch and sag with the changing weather, eventually exceeding the planned tolerances. The excessive sags can then cause serious accidents, while hindering the durability of the power lines. We used photogrammetric techniques with a low-cost drone to achieve efficient 3D mapping of power lines that are often difficult to approach. Unlike the conventional image-to-object space approach, we used the object-to-image space approach using cubic grid points. We processed four strips of aerial images to automatically extract the power line points in the object space. Experimental results showed that the approach could successfully extract the positions of the power line points for power line generation and sag measurement with the elevation accuracy of a few centimeters.

  14. Influences of multiple memory systems on auditory mental image acuity.

    Science.gov (United States)

    Navarro Cebrian, Ana; Janata, Petr

    2010-05-01

    The influence of different memory systems and associated attentional processes on the acuity of auditory images, formed for the purpose of making intonation judgments, was examined across three experiments using three different task types (cued-attention, imagery, and two-tone discrimination). In experiment 1 the influence of implicit long-term memory for musical scale structure was manipulated by varying the scale degree (leading tone versus tonic) of the probe note about which a judgment had to be made. In experiments 2 and 3 the ability of short-term absolute pitch knowledge to develop was manipulated by presenting blocks of trials in the same key or in seven different keys. The acuity of auditory images depended on all of these manipulations. Within individual listeners, thresholds in the two-tone discrimination and cued-attention conditions were closely related. In many listeners, cued-attention thresholds were similar to thresholds in the imagery condition, and depended on the amount of training individual listeners had in playing a musical instrument. The results indicate that mental images formed at a sensory/cognitive interface for the purpose of making perceptual decisions are highly malleable.

  15. Conventional MRI and magnetisation transfer imaging of tumour-like multiple sclerosis in a child

    International Nuclear Information System (INIS)

    Metafratzi, Z.; Argyropoulou, M.I.; Efremidis, S.C.; Tzoufi, M.; Papadopoulou, Z.

    2002-01-01

    Tumefactive multiple sclerosis is a rare entity in children. Differential diagnosis includes other mass lesions such as neoplasm and abscess. A case of tumefactive multiple sclerosis in a child is presented. The open-ring pattern of enhancement on conventional MRI and magnetisation transfer imaging was important for the initial diagnosis and the evaluation of the course of the disease. (orig.)

  16. New Hybrid Variational Recovery Model for Blurred Images with Multiplicative Noise

    DEFF Research Database (Denmark)

    Dong, Yiqiu; Zeng, Tieyong

    2013-01-01

    A new hybrid variational model for recovering blurred images in the presence of multiplicative noise is proposed. Inspired by previous work on multiplicative noise removal, an I-divergence technique is used to build a strictly convex model under a condition that ensures the uniqueness...

  17. Robust image registration for multiple exposure high dynamic range image synthesis

    Science.gov (United States)

    Yao, Susu

    2011-03-01

    Image registration is an important preprocessing technique in high dynamic range (HDR) image synthesis. This paper proposed a robust image registration method for aligning a group of low dynamic range images (LDR) that are captured with different exposure times. Illumination change and photometric distortion between two images would result in inaccurate registration. We propose to transform intensity image data into phase congruency to eliminate the effect of the changes in image brightness and use phase cross correlation in the Fourier transform domain to perform image registration. Considering the presence of non-overlapped regions due to photometric distortion, evolutionary programming is applied to search for the accurate translation parameters so that the accuracy of registration is able to be achieved at a hundredth of a pixel level. The proposed algorithm works well for under and over-exposed image registration. It has been applied to align LDR images for synthesizing high quality HDR images..

  18. A next-generation sequencing method for overcoming the multiple gene copy problem in polyploid phylogenetics, applied to Poa grasses

    Directory of Open Access Journals (Sweden)

    Robin Charles

    2011-03-01

    Full Text Available Abstract Background Polyploidy is important from a phylogenetic perspective because of its immense past impact on evolution and its potential future impact on diversification, survival and adaptation, especially in plants. Molecular population genetics studies of polyploid organisms have been difficult because of problems in sequencing multiple-copy nuclear genes using Sanger sequencing. This paper describes a method for sequencing a barcoded mixture of targeted gene regions using next-generation sequencing methods to overcome these problems. Results Using 64 3-bp barcodes, we successfully sequenced three chloroplast and two nuclear gene regions (each of which contained two gene copies with up to two alleles per individual in a total of 60 individuals across 11 species of Australian Poa grasses. This method had high replicability, a low sequencing error rate (after appropriate quality control and a low rate of missing data. Eighty-eight percent of the 320 gene/individual combinations produced sequence reads, and >80% of individuals produced sufficient reads to detect all four possible nuclear alleles of the homeologous nuclear loci with 95% probability. We applied this method to a group of sympatric Australian alpine Poa species, which we discovered to share an allopolyploid ancestor with a group of American Poa species. All markers revealed extensive allele sharing among the Australian species and so we recommend that the current taxonomy be re-examined. We also detected hypermutation in the trnH-psbA marker, suggesting it should not be used as a land plant barcode region. Some markers indicated differentiation between Tasmanian and mainland samples. Significant positive spatial genetic structure was detected at Conclusions Our results demonstrate that 454 sequencing of barcoded amplicon mixtures can be used to reliably sample all alleles of homeologous loci in polyploid species and successfully investigate phylogenetic relationships among

  19. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  20. High Dynamic Velocity Range Particle Image Velocimetry Using Multiple Pulse Separation Imaging

    Directory of Open Access Journals (Sweden)

    Tadhg S. O’Donovan

    2010-12-01

    Full Text Available The dynamic velocity range of particle image velocimetry (PIV is determined by the maximum and minimum resolvable particle displacement. Various techniques have extended the dynamic range, however flows with a wide velocity range (e.g., impinging jets still challenge PIV algorithms. A new technique is presented to increase the dynamic velocity range by over an order of magnitude. The multiple pulse separation (MPS technique (i records series of double-frame exposures with different pulse separations, (ii processes the fields using conventional multi-grid algorithms, and (iii yields a composite velocity field with a locally optimized pulse separation. A robust criterion determines the local optimum pulse separation, accounting for correlation strength and measurement uncertainty. Validation experiments are performed in an impinging jet flow, using laser-Doppler velocimetry as reference measurement. The precision of mean flow and turbulence quantities is significantly improved compared to conventional PIV, due to the increase in dynamic range. In a wide range of applications, MPS PIV is a robust approach to increase the dynamic velocity range without restricting the vector evaluation methods.

  1. High dynamic velocity range particle image velocimetry using multiple pulse separation imaging.

    Science.gov (United States)

    Persoons, Tim; O'Donovan, Tadhg S

    2011-01-01

    The dynamic velocity range of particle image velocimetry (PIV) is determined by the maximum and minimum resolvable particle displacement. Various techniques have extended the dynamic range, however flows with a wide velocity range (e.g., impinging jets) still challenge PIV algorithms. A new technique is presented to increase the dynamic velocity range by over an order of magnitude. The multiple pulse separation (MPS) technique (i) records series of double-frame exposures with different pulse separations, (ii) processes the fields using conventional multi-grid algorithms, and (iii) yields a composite velocity field with a locally optimized pulse separation. A robust criterion determines the local optimum pulse separation, accounting for correlation strength and measurement uncertainty. Validation experiments are performed in an impinging jet flow, using laser-Doppler velocimetry as reference measurement. The precision of mean flow and turbulence quantities is significantly improved compared to conventional PIV, due to the increase in dynamic range. In a wide range of applications, MPS PIV is a robust approach to increase the dynamic velocity range without restricting the vector evaluation methods.

  2. Clinical diagnostic criteria of multiple sclerosis: the role of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Belair, M.; Girard, M.

    2004-01-01

    The objective of this article is to summarize the diagnostic criteria recommended by the International Panel on the Diagnosis of Multiple Sclerosis in 2001. The recommendations of another working group, the Consortium of Multiple Sclerosis Centers Consensus Meeting, which met in Vancouver in 2001, concerning the diagnosis and follow-up of patients with multiple sclerosis are also presented in an effort to standardize the protocols for magnetic resonance imaging of these patients. (author)

  3. Characterization of platelet adhesion under flow using microscopic image sequence analysis.

    Science.gov (United States)

    Machin, M; Santomaso, A; Cozzi, M R; Battiston, M; Mazzuccato, M; De Marco, L; Canu, P

    2005-07-01

    A method for quantitative analysis of platelet deposition under flow is discussed here. The model system is based upon perfusion of blood platelets over an adhesive substrate immobilized on a glass coverslip acting as the lower surface of a rectangular flow chamber. The perfusion apparatus is mounted onto an inverted microscope equipped with epifluorescent illumination and intensified CCD video camera. Characterization is based on information obtained from a specific image analysis method applied to continuous sequences of microscopical images. Platelet recognition across the sequence of images is based on a time-dependent, bidimensional, gaussian-like pdf. Once a platelet is located,the variation of its position and shape as a function of time (i.e., the platelet history) can be determined. Analyzing the history we can establish if the platelet is moving on the surface, the frequency of this movement and the distance traveled before its resumes the velocity of a non-interacting cell. Therefore, we can determine how long the adhesion would last which is correlated to the resistance of the platelet-substrate bond. This algorithm enables the dynamic quantification of trajectories, as well as residence times, arrest and release frequencies for a high numbers of platelets at the same time. Statistically significant conclusions on platelet-surface interactions can then be obtained. An image analysis tool of this kind can dramatically help the investigation and characterization of the thrombogenic properties of artificial surfaces such as those used in artificial organs and biomedical devices.

  4. Enriching Student Concept Images: Teaching and Learning Fractions through a Multiple-Embodiment Approach

    Science.gov (United States)

    Zhang, Xiaofen; Clements, M. A.; Ellerton, Nerida F.

    2015-01-01

    This study investigated how fifth-grade children's concept images of the unit fractions represented by the symbols 1/2, 1/3/ and 1/4 changed as a result of their participation in an instructional intervention based on multiple embodiments of fraction concepts. The participants' concept images were examined through pre- and post-teaching written…

  5. Effect of multiple circular holes Fraunhofer diffraction for the infrared optical imaging

    Science.gov (United States)

    Lu, Chunlian; Lv, He; Cao, Yang; Cai, Zhisong; Tan, Xiaojun

    2014-11-01

    With the development of infrared optics, infrared optical imaging systems play an increasingly important role in modern optical imaging systems. Infrared optical imaging is used in industry, agriculture, medical, military and transportation. But in terms of infrared optical imaging systems which are exposed for a long time, some contaminations will affect the infrared optical imaging. When the contamination contaminate on the lens surface of the optical system, it would affect diffraction. The lens can be seen as complementary multiple circular holes screen happen Fraunhofer diffraction. According to Babinet principle, you can get the diffraction of the imaging system. Therefore, by studying the multiple circular holes Fraunhofer diffraction, conclusions can be drawn about the effect of infrared imaging. This paper mainly studies the effect of multiple circular holes Fraunhofer diffraction for the optical imaging. Firstly, we introduce the theory of Fraunhofer diffraction and Point Spread Function. Point Spread Function is a basic tool to evaluate the image quality of the optical system. Fraunhofer diffraction will affect Point Spread Function. Then, the results of multiple circular holes Fraunhofer diffraction are given for different hole size and hole spacing. We choose the hole size from 0.1mm to 1mm and hole spacing from 0.3mm to 0.8mm. The infrared wavebands of optical imaging are chosen from 1μm to 5μm. We use the MATLAB to simulate light intensity distribution of multiple circular holes Fraunhofer diffraction. Finally, three-dimensional diffraction maps of light intensity are given to contrast.

  6. Unexpected inheritance: multiple integrations of ancient bornavirus and ebolavirus/marburgvirus sequences in vertebrate genomes.

    Science.gov (United States)

    Belyi, Vladimir A; Levine, Arnold J; Skalka, Anna Marie

    2010-07-29

    Vertebrate genomes contain numerous copies of retroviral sequences, acquired over the course of evolution. Until recently they were thought to be the only type of RNA viruses to be so represented, because integration of a DNA copy of their genome is required for their replication. In this study, an extensive sequence comparison was conducted in which 5,666 viral genes from all known non-retroviral families with single-stranded RNA genomes were matched against the germline genomes of 48 vertebrate species, to determine if such viruses could also contribute to the vertebrate genetic heritage. In 19 of the tested vertebrate species, we discovered as many as 80 high-confidence examples of genomic DNA sequences that appear to be derived, as long ago as 40 million years, from ancestral members of 4 currently circulating virus families with single strand RNA genomes. Surprisingly, almost all of the sequences are related to only two families in the Order Mononegavirales: the Bornaviruses and the Filoviruses, which cause lethal neurological disease and hemorrhagic fevers, respectively. Based on signature landmarks some, and perhaps all, of the endogenous virus-like DNA sequences appear to be LINE element-facilitated integrations derived from viral mRNAs. The integrations represent genes that encode viral nucleocapsid, RNA-dependent-RNA-polymerase, matrix and, possibly, glycoproteins. Integrations are generally limited to one or very few copies of a related viral gene per species, suggesting that once the initial germline integration was obtained (or selected), later integrations failed or provided little advantage to the host. The conservation of relatively long open reading frames for several of the endogenous sequences, the virus-like protein regions represented, and a potential correlation between their presence and a species' resistance to the diseases caused by these pathogens, are consistent with the notion that their products provide some important biological

  7. Unexpected inheritance: multiple integrations of ancient bornavirus and ebolavirus/marburgvirus sequences in vertebrate genomes.

    Directory of Open Access Journals (Sweden)

    Vladimir A Belyi

    2010-07-01

    Full Text Available Vertebrate genomes contain numerous copies of retroviral sequences, acquired over the course of evolution. Until recently they were thought to be the only type of RNA viruses to be so represented, because integration of a DNA copy of their genome is required for their replication. In this study, an extensive sequence comparison was conducted in which 5,666 viral genes from all known non-retroviral families with single-stranded RNA genomes were matched against the germline genomes of 48 vertebrate species, to determine if such viruses could also contribute to the vertebrate genetic heritage. In 19 of the tested vertebrate species, we discovered as many as 80 high-confidence examples of genomic DNA sequences that appear to be derived, as long ago as 40 million years, from ancestral members of 4 currently circulating virus families with single strand RNA genomes. Surprisingly, almost all of the sequences are related to only two families in the Order Mononegavirales: the Bornaviruses and the Filoviruses, which cause lethal neurological disease and hemorrhagic fevers, respectively. Based on signature landmarks some, and perhaps all, of the endogenous virus-like DNA sequences appear to be LINE element-facilitated integrations derived from viral mRNAs. The integrations represent genes that encode viral nucleocapsid, RNA-dependent-RNA-polymerase, matrix and, possibly, glycoproteins. Integrations are generally limited to one or very few copies of a related viral gene per species, suggesting that once the initial germline integration was obtained (or selected, later integrations failed or provided little advantage to the host. The conservation of relatively long open reading frames for several of the endogenous sequences, the virus-like protein regions represented, and a potential correlation between their presence and a species' resistance to the diseases caused by these pathogens, are consistent with the notion that their products provide some important

  8. Magnetic resonance imaging in monitoring of treatment of multiple sclerosis

    International Nuclear Information System (INIS)

    Bekiesinska-Figatowska, M.; Walecki, J.; Stelmasiak, Z.

    1996-01-01

    The purpose of the study was to establish the value of MR in monitoring of treatment of multiple sclerosis with new drug 2-CDA and placebo. 83 patients (51 women, 32 men) were examined - 81 of them twice, 66 - three times: before and after 6 and 12 courses of treatment. Toshiba MRT50A machine was used. After the first 6 courses of treatment the number of new plaques was twice as big in placebo group than in 2-CDA group. After 12 courses it turned out that a certain inhibitory influence of 2-CDA on new plaques' appearance was more evident after 15 than 3 months after the end of its administration. This may indicate the delayed action of 2-CDA but requires further investigation. (author)

  9. Autosomal recessive osteopetrosis with a unique imaging finding: multiple encephaloceles

    International Nuclear Information System (INIS)

    Saglam, Dilek; Bilgici, Meltem Ceyhan; Bekci, Tuemay; Albayrak, Canan; Albayrak, Davut

    2017-01-01

    Osteopetrosis is a hereditary form of sclerosing bone dysplasia with various radiological and clinical presentations. The autosomal recessive type, also known as malignant osteopetrosis, is the most severe type, with the early onset of manifestations. A 5-month-old infant was admitted to our hospital with recurrent respiratory tract infections. Chest X-ray and skeletal survey revealed the classic findings of osteopetrosis, including diffuse osteosclerosis and bone within a bone appearance. At follow-up, the patient presented with, thickened calvarium, multiple prominent encephaloceles, and dural calcifications leading to the intracranial clinical manifestations with bilateral hearing and sight loss. Autosomal recessive osteopetrosis is one of the causes of encephaloceles and this finding may become dramatic if untreated. (orig.)

  10. Autosomal recessive osteopetrosis with a unique imaging finding: multiple encephaloceles

    Energy Technology Data Exchange (ETDEWEB)

    Saglam, Dilek; Bilgici, Meltem Ceyhan; Bekci, Tuemay [Ondokuz Mayis University, Department of Radiology, School of Medicine, Kurupelit, Samsun (Turkey); Albayrak, Canan; Albayrak, Davut [Ondokuz Mayis University, Department of Pediatrics, School of Medicine, Kurupelit, Samsun (Turkey)

    2017-05-15

    Osteopetrosis is a hereditary form of sclerosing bone dysplasia with various radiological and clinical presentations. The autosomal recessive type, also known as malignant osteopetrosis, is the most severe type, with the early onset of manifestations. A 5-month-old infant was admitted to our hospital with recurrent respiratory tract infections. Chest X-ray and skeletal survey revealed the classic findings of osteopetrosis, including diffuse osteosclerosis and bone within a bone appearance. At follow-up, the patient presented with, thickened calvarium, multiple prominent encephaloceles, and dural calcifications leading to the intracranial clinical manifestations with bilateral hearing and sight loss. Autosomal recessive osteopetrosis is one of the causes of encephaloceles and this finding may become dramatic if untreated. (orig.)

  11. ACM-based automatic liver segmentation from 3-D CT images by combining multiple atlases and improved mean-shift techniques.

    Science.gov (United States)

    Ji, Hongwei; He, Jiangping; Yang, Xin; Deklerck, Rudi; Cornelis, Jan

    2013-05-01

    In this paper, we present an autocontext model(ACM)-based automatic liver segmentation algorithm, which combines ACM, multiatlases, and mean-shift techniques to segment liver from 3-D CT images. Our algorithm is a learning-based method and can be divided into two stages. At the first stage, i.e., the training stage, ACM is performed to learn a sequence of classifiers in each atlas space (based on each atlas and other aligned atlases). With the use of multiple atlases, multiple sequences of ACM-based classifiers are obtained. At the second stage, i.e., the segmentation stage, the test image will be segmented in each atlas space by applying each sequence of ACM-based classifiers. The final segmentation result will be obtained by fusing segmentation results from all atlas spaces via a multiclassifier fusion technique. Specially, in order to speed up segmentation, given a test image, we first use an improved mean-shift algorithm to perform over-segmentation and then implement the region-based image labeling instead of the original inefficient pixel-based image labeling. The proposed method is evaluated on the datasets of MICCAI 2007 liver segmentation challenge. The experimental results show that the average volume overlap error and the average surface distance achieved by our method are 8.3% and 1.5 m, respectively, which are comparable to the results reported in the existing state-of-the-art work on liver segmentation.

  12. Selection of optimal pulse sequences for conventional and dynamic MR imaging with Gd-DTPA; A fundamental study

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Miho; Kita, Keisuke; Maeda, Masayuki (Wakayama Medical Coll. (Japan)) (and others)

    1989-11-01

    Gadolinium-DTPA (Gd-DTPA) enhances contrast between tissues in magnetic resonance (MR) imaging. The enhancement of tissues depends partly upon the pulse sequences, and the optimal pulse sequence is also influenced by the tissue cncentration of Gd-DTPA. We prepared phantoms of 25% albumin solutions with various concentrations of Gd-DTPA, and imaged them using various pulse sequences with 1.5-T MR system. We also performed MR imaging of 16 patients with tumors (10 brain tumors and 6 hepatic tumors) before and after intravenous administration of Gd-DTPA (0.1 mmol/kg); 6 patients with hepatic tumors underwent dynamic MR imaging during suspended respiration. We made a theoretical equation to calculate the concentration of Gd-DTPA and estimated its tissue concentration in tumors at 0{approx}0.2 mmol/kg. Within these tissue concentrations, the enhancement-to-noise (E/N) ratio was larger in FISP (flip angle of 90deg, TR pf 300 msec, minimal TE) and SE (TR of 400 msec, minimal TE) sequences than in other sequences observed. These sequences may be preferable for conventional enhanced-MRI. Among the pulse sequences with TR of less than 100 msec, FISP (flip angle of 90deg, TR of less than 100 msec, minimal TE) had the largest E/N ratio; which may be useful for dynamic MRI during suspended respiration. The importance of selecting the optimal pulse sequences according to the imaging modality used will be discussed. (author).

  13. A new feedback image encryption scheme based on perturbation with dynamical compound chaotic sequence cipher generator

    Science.gov (United States)

    Tong, Xiaojun; Cui, Minggen; Wang, Zhu

    2009-07-01

    The design of the new compound two-dimensional chaotic function is presented by exploiting two one-dimensional chaotic functions which switch randomly, and the design is used as a chaotic sequence generator which is proved by Devaney's definition proof of chaos. The properties of compound chaotic functions are also proved rigorously. In order to improve the robustness against difference cryptanalysis and produce avalanche effect, a new feedback image encryption scheme is proposed using the new compound chaos by selecting one of the two one-dimensional chaotic functions randomly and a new image pixels method of permutation and substitution is designed in detail by array row and column random controlling based on the compound chaos. The results from entropy analysis, difference analysis, statistical analysis, sequence randomness analysis, cipher sensitivity analysis depending on key and plaintext have proven that the compound chaotic sequence cipher can resist cryptanalytic, statistical and brute-force attacks, and especially it accelerates encryption speed, and achieves higher level of security. By the dynamical compound chaos and perturbation technology, the paper solves the problem of computer low precision of one-dimensional chaotic function.

  14. Time integration and statistical regulation applied to mobile objects detection in a sequence of images

    International Nuclear Information System (INIS)

    Letang, Jean-Michel

    1993-01-01

    This PhD thesis deals with the detection of moving objects in monocular image sequences. The first section presents the inherent problems of motion analysis in real applications. We propose a method robust to perturbations frequently encountered during acquisition of outdoor scenes. It appears three main directions for investigations, all of them pointing out the importance of the temporal axis, which is a specific dimension for motion analysis. In the first part, the image sequence is considered as a set of temporal signals. The temporal multi-scale decomposition enables the characterization of various dynamical behaviors of the objects being in the scene at a given instant. A second module integrates motion information. This elementary trajectography of moving objects provides a temporal prediction map, giving a confidence level of motion presence. Interactions between both sets of data are expressed within a statistical regularization. Markov random field models supply a formal framework to convey a priori knowledge of the primitives to be evaluated. A calibration method with qualitative boxes is presented to estimate model parameters. Our approach requires only simple computations and leads to a rather fast algorithm, that we evaluate in the last section over various typical sequences. (author) [fr

  15. Focal dynamics of multiple filaments: Microscopic imaging and reconstruction

    International Nuclear Information System (INIS)

    Kiran, P. Prem; Bagchi, Suman; Kumar, G. Ravindra; Krishnan, Siva Rama; Arnold, C. L.; Couairon, A.

    2010-01-01

    We observe the complete dynamics of the propagation of very intense, femtosecond laser pulses in air under tight focusing conditions via direct imaging of the entire interaction zone. The whole life history of the focused pulses is then reconstructed by means of numerical simulations. We show that beam breakup leads to a dual-rate increase in filament numbers with laser power. Linearly and circularly polarized pulses give rise to beam breakup and fusion governed by external focusing conditions. For tight focusing conditions, intensity saturation due to plasma generation and nonlinear losses does not limit the intensity growth, thereby giving access to a new propagation regime featured by an efficient laser energy deposition in fully ionized air and intense 10 15 W/cm 2 pulses at the focus.

  16. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    International Nuclear Information System (INIS)

    Novell, A; Sennoga, CA; Escoffre, JM; Chaline, J; Bouakaz, A

    2014-01-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz; amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue ® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at −3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI. (paper)

  17. Noninvasive imaging of multiple myeloma using near infrared fluorescent molecular probe

    Science.gov (United States)

    Hathi, Deep; Zhou, Haiying; Bollerman-Nowlis, Alex; Shokeen, Monica; Akers, Walter J.

    2016-03-01

    Multiple myeloma is a plasma cell malignancy characterized by monoclonal gammopathy and osteolytic bone lesions. Multiple myeloma is most commonly diagnosed in late disease stages, presenting with pathologic fracture. Early diagnosis and monitoring of disease status may improve quality of life and long-term survival for multiple myeloma patients from what is now a devastating and fatal disease. We have developed a near-infrared targeted fluorescent molecular probe with high affinity to the α4β1 integrin receptor (VLA-4)overexpressed by a majority of multiple myeloma cells as a non-radioactive analog to PET/CT tracer currently being developed for human diagnostics. A near-infrared dye that emits about 700 nm was conjugated to a high affinity peptidomimmetic. Binding affinity and specificity for multiple myeloma cells was investigated in vitro by tissue staining and flow cytometry. After demonstration of sensitivity and specificity, preclinical optical imaging studies were performed to evaluate tumor specificity in murine subcutaneous and metastatic multiple myeloma models. The VLA-4-targeted molecular probe showed high affinity for subcutaneous MM tumor xenografts. Importantly, tumor cells specific accumulation in the bone marrow of metastatic multiple myeloma correlated with GFP signal from transfected cells. Ex vivo flow cytometry of tumor tissue and bone marrow further corroborated in vivo imaging data, demonstrating the specificity of the novel agent and potential for quantitative imaging of multiple myeloma burden in these models.

  18. JDet: interactive calculation and visualization of function-related conservation patterns in multiple sequence alignments and structures.

    Science.gov (United States)

    Muth, Thilo; García-Martín, Juan A; Rausell, Antonio; Juan, David; Valencia, Alfonso; Pazos, Florencio

    2012-02-15

    We have implemented in a single package all the features required for extracting, visualizing and manipulating fully conserved positions as well as those with a family-dependent conservation pattern in multiple sequence alignments. The program allows, among other things, to run different methods for extracting these positions, combine the results and visualize them in protein 3D structures and sequence spaces. JDet is a multiplatform application written in Java. It is freely available, including the source code, at http://csbg.cnb.csic.es/JDet. The package includes two of our recently developed programs for detecting functional positions in protein alignments (Xdet and S3Det), and support for other methods can be added as plug-ins. A help file and a guided tutorial for JDet are also available.

  19. Managing complex processing of medical image sequences by program supervision techniques

    Science.gov (United States)

    Crubezy, Monica; Aubry, Florent; Moisan, Sabine; Chameroy, Virginie; Thonnat, Monique; Di Paola, Robert

    1997-05-01

    Our objective is to offer clinicians wider access to evolving medical image processing (MIP) techniques, crucial to improve assessment and quantification of physiological processes, but difficult to handle for non-specialists in MIP. Based on artificial intelligence techniques, our approach consists in the development of a knowledge-based program supervision system, automating the management of MIP libraries. It comprises a library of programs, a knowledge base capturing the expertise about programs and data and a supervision engine. It selects, organizes and executes the appropriate MIP programs given a goal to achieve and a data set, with dynamic feedback based on the results obtained. It also advises users in the development of new procedures chaining MIP programs.. We have experimented the approach for an application of factor analysis of medical image sequences as a means of predicting the response of osteosarcoma to chemotherapy, with both MRI and NM dynamic image sequences. As a result our program supervision system frees clinical end-users from performing tasks outside their competence, permitting them to concentrate on clinical issues. Therefore our approach enables a better exploitation of possibilities offered by MIP and higher quality results, both in terms of robustness and reliability.

  20. Artifact free T2{sup *}-weighted imaging at high spatial resolution using segmented EPI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Heiler, Patrick Michael; Schad, Lothar Rudi [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Schmitter, Sebastian [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiology

    2010-07-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2{sup *}-weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately {radical}2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2{sup *}-weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  1. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors

    International Nuclear Information System (INIS)

    Husstedt, H.W.; Sickert, M.; Koestler, H.; Haubitz, B.; Becker, H.

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure. (orig.)

  2. Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors.

    Science.gov (United States)

    Husstedt, H W; Sickert, M; Köstler, H; Haubitz, B; Becker, H

    2000-01-01

    The aim of this study was to quantify imaging characteristics of fast fluid-attenuated inversion recovery (FLAIR) sequence in brain tumors compared with T1-postcontrast- and T2-sequences. Fast-FLAIR-, T2 fast spin echo (FSE)-, and T1 SE postcontrast images of 74 patients with intracranial neoplasms were analyzed. Four neuroradiologists rated signal intensity and inhomogeneity of the tumor, rendering of cystic parts, demarcation of the tumor vs brain, of the tumor vs edema and of brain vs edema, as well as the presence of motion and of other artifacts. Data analysis was performed for histologically proven astrocytomas, glioblastomas, and meningiomas, for tumors with poor contrast enhancement, and for all patients pooled. Only for tumors with poor contrast enhancement (n = 12) did fast FLAIR provide additional information about the lesion. In these cases, signal intensity, demarcation of the tumor vs brain, and differentiation of the tumor vs edema were best using fast FLAIR. In all cases, rendering of the tumor's inner structure was poor. For all other tumor types, fast FLAIR did not give clinically relevant information, the only exception being a better demarcation of the edema from brain tissue. Artifacts rarely interfered with evaluation of fast-FLAIR images. Thus, fast FLAIR cannot replace T2-weighted series. It provides additional information only in tumors with poor contrast enhancement. It is helpful for defining the exact extent of the edema of any tumor but gives little information about their inner structure.

  3. Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences

    International Nuclear Information System (INIS)

    Heiler, Patrick Michael; Schad, Lothar Rudi; Schmitter, Sebastian

    2010-01-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2 * -weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately √2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2 * -weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  4. A survey of endogenous retrovirus (ERV) sequences in the vicinity of multiple sclerosis (MS)-associated single nucleotide polymorphisms (SNPs).

    Science.gov (United States)

    Brütting, Christine; Emmer, Alexander; Kornhuber, Malte; Staege, Martin S

    2016-08-01

    Although multiple sclerosis (MS) is one of the most common central nervous system diseases in young adults, little is known about its etiology. Several human endogenous retroviruses (ERVs) are considered to play a role in MS. We are interested in which ERVs can be identified in the vicinity of MS associated genetic marker to find potential initiators of MS. We analysed the chromosomal regions surrounding 58 single nucleotide polymorphisms (SNPs) that are associated with MS identified in one of the last major genome wide association studies. We scanned these regions for putative endogenous retrovirus sequences with large open reading frames (ORFs). We observed that more retrovirus-related putative ORFs exist in the relatively close vicinity of SNP marker indices in multiple sclerosis compared to control SNPs. We found very high homologies to HERV-K, HCML-ARV, XMRV, Galidia ERV, HERV-H/env62 and XMRV-like mouse endogenous retrovirus mERV-XL. The associated genes (CYP27B1, CD6, CD58, MPV17L2, IL12RB1, CXCR5, PTGER4, TAGAP, TYK2, ICAM3, CD86, GALC, GPR65 as well as the HLA DRB1*1501) are mainly involved in the immune system, but also in vitamin D regulation. The most frequently detected ERV sequences are related to the multiple sclerosis-associated retrovirus, the human immunodeficiency virus 1, HERV-K, and the Simian foamy virus. Our data shows that there is a relation between MS associated SNPs and the number of retroviral elements compared to control. Our data identifies new ERV sequences that have not been associated with MS, so far.

  5. UAV remote sensing atmospheric degradation image restoration based on multiple scattering APSF estimation

    Science.gov (United States)

    Qiu, Xiang; Dai, Ming; Yin, Chuan-li

    2017-09-01

    Unmanned aerial vehicle (UAV) remote imaging is affected by the bad weather, and the obtained images have the disadvantages of low contrast, complex texture and blurring. In this paper, we propose a blind deconvolution model based on multiple scattering atmosphere point spread function (APSF) estimation to recovery the remote sensing image. According to Narasimhan analytical theory, a new multiple scattering restoration model is established based on the improved dichromatic model. Then using the L0 norm sparse priors of gradient and dark channel to estimate APSF blur kernel, the fast Fourier transform is used to recover the original clear image by Wiener filtering. By comparing with other state-of-the-art methods, the proposed method can correctly estimate blur kernel, effectively remove the atmospheric degradation phenomena, preserve image detail information and increase the quality evaluation indexes.

  6. PARAGON-IPS: A Portable Imaging Software System For Multiple Generations Of Image Processing Hardware

    Science.gov (United States)

    Montelione, John

    1989-07-01

    Paragon-IPS is a comprehensive software system which is available on virtually all generations of image processing hardware. It is designed for an image processing department or a scientist and engineer who is doing image processing full-time. It is being used by leading R&D labs in government agencies and Fortune 500 companies. Applications include reconnaissance, non-destructive testing, remote sensing, medical imaging, etc.

  7. Multiple aspects of ATP-dependent nucleosome translocation by RSC and Mi-2 are directed by the underlying DNA sequence.

    Directory of Open Access Journals (Sweden)

    Joke J F A van Vugt

    Full Text Available BACKGROUND: Chromosome structure, DNA metabolic processes and cell type identity can all be affected by changing the positions of nucleosomes along chromosomal DNA, a reaction that is catalysed by SNF2-type ATP-driven chromatin remodelers. Recently it was suggested that in vivo, more than 50% of the nucleosome positions can be predicted simply by DNA sequence, especially within promoter regions. This seemingly contrasts with remodeler induced nucleosome mobility. The ability of remodeling enzymes to mobilise nucleosomes over short DNA distances is well documented. However, the nucleosome translocation processivity along DNA remains elusive. Furthermore, it is unknown what determines the initial direction of movement and how new nucleosome positions are adopted. METHODOLOGY/PRINCIPAL FINDINGS: We have used AFM imaging and high resolution PAGE of mononucleosomes on 600 and 2500 bp DNA molecules to analyze ATP-dependent nucleosome repositioning by native and recombinant SNF2-type enzymes. We report that the underlying DNA sequence can control the initial direction of translocation, translocation distance, as well as the new positions adopted by nucleosomes upon enzymatic mobilization. Within a strong nucleosomal positioning sequence both recombinant Drosophila Mi-2 (CHD-type and native RSC from yeast (SWI/SNF-type repositioned the nucleosome at 10 bp intervals, which are intrinsic to the positioning sequence. Furthermore, RSC-catalyzed nucleosome translocation was noticeably more efficient when beyond the influence of this sequence. Interestingly, under limiting ATP conditions RSC preferred to position the nucleosome with 20 bp intervals within the positioning sequence, suggesting that native RSC preferentially translocates nucleosomes with 15 to 25 bp DNA steps. CONCLUSIONS/SIGNIFICANCE: Nucleosome repositioning thus appears to be influenced by both remodeler intrinsic and DNA sequence specific properties that interplay to define ATPase

  8. Hierarchical folding of multiple sequence alignments for the prediction of structures and RNA-RNA interactions

    DEFF Research Database (Denmark)

    Seemann, Ernst Stefan; Richter, Andreas S.; Gorodkin, Jan

    2010-01-01

    of that used for individual multiple alignments. Results: We derived a rather extensive algorithm. One of the advantages of our approach (in contrast to other RNARNA interaction prediction methods) is the application of covariance detection and prediction of pseudoknots between intra- and inter-molecular base...... pairs. As a proof of concept, we show an example and discuss the strengths and weaknesses of the approach....

  9. Geographic isolates of Lymantria dispar multiple nucleopolyhedrovirus: Genome sequence analysis and pathogenicity against European and Asian gypsy moth strains.

    Science.gov (United States)

    Harrison, Robert L; Rowley, Daniel L; Keena, Melody A

    2016-06-01

    Isolates of the baculovirus species Lymantria dispar multiple nucleopolyhedrovirus have been formulated and applied to suppress outbreaks of the gypsy moth, L. dispar. To evaluate the genetic diversity in this species at the genomic level, the genomes of three isolates from Massachusetts, USA (LdMNPV-Ab-a624), Spain (LdMNPV-3054), and Japan (LdMNPV-3041) were sequenced and compared with four previously determined LdMNPV genome sequences. The LdMNPV genome sequences were collinear and contained the same homologous repeats (hrs) and clusters of baculovirus repeat orf (bro) gene family members in the same relative positions in their genomes, although sequence identities in these regions were low. Of 146 non-bro ORFs annotated in the genome of the representative isolate LdMNPV 5-6, 135 ORFs were found in every other LdMNPV genome, including the 37 core genes of Baculoviridae and other genes conserved in genus Alphabaculovirus. Phylogenetic inference with an alignment of the core gene nucleotide sequences grouped isolates 3041 (Japan) and 2161 (Korea) separately from a cluster containing isolates from Europe, North America, and Russia. To examine phenotypic diversity, bioassays were carried out with a selection of isolates against neonate larvae from three European gypsy moth (Lymantria dispar dispar) and three Asian gypsy moth (Lymantria dispar asiatica and Lymantria dispar japonica) colonies. LdMNPV isolates 2161 (Korea), 3029 (Russia), and 3041 (Japan) exhibited a greater degree of pathogenicity against all L. dispar strains than LdMNPV from a sample of Gypchek. This study provides additional information on the genetic diversity of LdMNPV isolates and their activity against the Asian gypsy moth, a potential invasive pest of North American trees and forests. Published by Elsevier Inc.

  10. Face Image Retrieval of Efficient Sparse Code words and Multiple Attribute in Binning Image

    Directory of Open Access Journals (Sweden)

    Suchitra S

    2017-08-01

    Full Text Available ABSTRACT In photography, face recognition and face retrieval play an important role in many applications such as security, criminology and image forensics. Advancements in face recognition make easier for identity matching of an individual with attributes. Latest development in computer vision technologies enables us to extract facial attributes from the input image and provide similar image results. In this paper, we propose a novel LOP and sparse codewords method to provide similar matching results with respect to input query image. To improve accuracy in image results with input image and dynamic facial attributes, Local octal pattern algorithm [LOP] and Sparse codeword applied in offline and online. The offline and online procedures in face image binning techniques apply with sparse code. Experimental results with Pubfig dataset shows that the proposed LOP along with sparse codewords able to provide matching results with increased accuracy of 90%.

  11. The complete sequence of the first Spodoptera frugiperda Betabaculovirus genome: a natural multiple recombinant virus.

    Science.gov (United States)

    Cuartas, Paola E; Barrera, Gloria P; Belaich, Mariano N; Barreto, Emiliano; Ghiringhelli, Pablo D; Villamizar, Laura F

    2015-01-20

    Spodoptera frugiperda (Lepidoptera: Noctuidae) is a major pest in maize crops in Colombia, and affects several regions in America. A granulovirus isolated from S. frugiperda (SfGV VG008) has potential as an enhancer of insecticidal activity of previously described nucleopolyhedrovirus from the same insect species (SfMNPV). The SfGV VG008 genome was sequenced and analyzed showing circular double stranded DNA of 140,913 bp encoding 146 putative ORFs that include 37 Baculoviridae core genes, 88 shared with betabaculoviruses, two shared only with betabaculoviruses from Noctuide insects, two shared with alphabaculoviruses, three copies of own genes (paralogs) and the other 14 corresponding to unique genes without representation in the other baculovirus species. Particularly, the genome encodes for important virulence factors such as 4 chitinases and 2 enhancins. The sequence analysis revealed the existence of eight homologous regions (hrs) and also suggests processes of gene acquisition by horizontal transfer including the SfGV VG008 ORFs 046/047 (paralogs), 059, 089 and 099. The bioinformatics evidence indicates that the genome donors of mentioned genes could be alpha- and/or betabaculovirus species. The previous reported ability of SfGV VG008 to naturally co-infect the same host with other virus show a possible mechanism to capture genes and thus improve its fitness.

  12. The Complete Sequence of the First Spodoptera frugiperda Betabaculovirus Genome: A Natural Multiple Recombinant Virus

    Directory of Open Access Journals (Sweden)

    Paola E. Cuartas

    2015-01-01

    Full Text Available Spodoptera frugiperda (Lepidoptera: Noctuidae is a major pest in maize crops in Colombia, and affects several regions in America. A granulovirus isolated from S. frugiperda (SfGV VG008 has potential as an enhancer of insecticidal activity of previously described nucleopolyhedrovirus from the same insect species (SfMNPV. The SfGV VG008 genome was sequenced and analyzed showing circular double stranded DNA of 140,913 bp encoding 146 putative ORFs that include 37 Baculoviridae core genes, 88 shared with betabaculoviruses, two shared only with betabaculoviruses from Noctuide insects, two shared with alphabaculoviruses, three copies of own genes (paralogs and the other 14 corresponding to unique genes without representation in the other baculovirus species. Particularly, the genome encodes for important virulence factors such as 4 chitinases and 2 enhancins. The sequence analysis revealed the existence of eight homologous regions (hrs and also suggests processes of gene acquisition by horizontal transfer including the SfGV VG008 ORFs 046/047 (paralogs, 059, 089 and 099. The bioinformatics evidence indicates that the genome donors of mentioned genes could be alpha- and/or betabaculovirus species. The previous reported ability of SfGV VG008 to naturally co-infect the same host with other virus show a possible mechanism to capture genes and thus improve its fitness.

  13. Sequence-based analysis of the microbial composition of water kefir from multiple sources.

    Science.gov (United States)

    Marsh, Alan J; O'Sullivan, Orla; Hill, Colin; Ross, R Paul; Cotter, Paul D

    2013-11-01

    Water kefir is a water-sucrose-based beverage, fermented by a symbiosis of bacteria and yeast to produce a final product that is lightly carbonated, acidic and that has a low alcohol percentage. The microorganisms present in water kefir are introduced via water kefir grains, which consist of a polysaccharide matrix in which the microorganisms are embedded. We aimed to provide a comprehensive sequencing-based analysis of the bacterial population of water kefir beverages and grains, while providing an initial insight into the corresponding fungal population. To facilitate this objective, four water kefirs were sourced from the UK, Canada and the United States. Culture-independent, high-throughput, sequencing-based analyses revealed that the bacterial fraction of each water kefir and grain was dominated by Zymomonas, an ethanol-producing bacterium, which has not previously been detected at such a scale. The other genera detected were representatives of the lactic acid bacteria and acetic acid bacteria. Our analysis of the fungal component established that it was comprised of the genera Dekkera, Hanseniaspora, Saccharomyces, Zygosaccharomyces, Torulaspora and Lachancea. This information will assist in the ultimate identification of the microorganisms responsible for the potentially health-promoting attributes of these beverages. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  14. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  15. Imaging of first-order surface-related multiples by reverse-time migration

    Science.gov (United States)

    Liu, Xuejian; Liu, Yike; Hu, Hao; Li, Peng; Khan, Majid

    2017-02-01

    Surface-related multiples have been utilized in the reverse-time migration (RTM) procedures, and additional illumination for subsurface can be provided. Meanwhile, many cross-talks are generated from undesired interactions between forward- and backward-propagated seismic waves. In this paper, subsequent to analysing and categorizing these cross-talks, we propose RTM of first-order multiples to avoid most undesired interactions in RTM of all-order multiples, where only primaries are forward-propagated and crosscorrelated with the backward-propagated first-order multiples. With primaries and multiples separated during regular seismic data processing as the input data, first-order multiples can be obtained by a two-step scheme: (1) the dual-prediction of higher-order multiples; and (2) the adaptive subtraction of predicted higher-order multiples from all-order multiples within local offset-time windows. In numerical experiments, two synthetic and a marine field data sets are used, where different cross-talks generated by RTM of all-order multiples can be identified and the proposed RTM of first-order multiples can provide a very interpretable image with a few cross-talks.

  16. Color Image Encryption Using Three-Dimensional Sine ICMIC Modulation Map and DNA Sequence Operations

    Science.gov (United States)

    Liu, Wenhao; Sun, Kehui; He, Yi; Yu, Mengyao

    Derived from Sine map and iterative chaotic map with infinite collapse (ICMIC), a three-dimensional hyperchaotic Sine ICMIC modulation map (3D-SIMM) is proposed based on a close-loop modulation coupling (CMC) method. Based on this map, a novel color image encryption algorithm is designed by employing a hybrid model of multidirectional circular permutation and deoxyribonucleic acid (DNA) masking. In this scheme, the pixel positions of image are scrambled by multidirectional circular permutation, and the pixel values are substituted by DNA sequence operations. The simulation results and security analysis show that the algorithm has good encryption effect and strong key sensitivity, and can resist brute-force, statistical, differential, known-plaintext and chosen-plaintext attacks.

  17. Event recognition in personal photo collections via multiple instance learning-based classification of multiple images

    Science.gov (United States)

    Ahmad, Kashif; Conci, Nicola; Boato, Giulia; De Natale, Francesco G. B.

    2017-11-01

    Over the last few years, a rapid growth has been witnessed in the number of digital photos produced per year. This rapid process poses challenges in the organization and management of multimedia collections, and one viable solution consists of arranging the media on the basis of the underlying events. However, album-level annotation and the presence of irrelevant pictures in photo collections make event-based organization of personal photo albums a more challenging task. To tackle these challenges, in contrast to conventional approaches relying on supervised learning, we propose a pipeline for event recognition in personal photo collections relying on a multiple instance-learning (MIL) strategy. MIL is a modified form of supervised learning and fits well for such applications with weakly labeled data. The experimental evaluation of the proposed approach is carried out on two large-scale datasets including a self-collected and a benchmark dataset. On both, our approach significantly outperforms the existing state-of-the-art.

  18. Imaging cardiac activation sequence during ventricular tachycardia in a canine model of nonischemic heart failure.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Yu, Long; Zhou, Zhaoye; Killingsworth, Cheryl R; He, Bin

    2015-01-15

    Noninvasive cardiac activation imaging of ventricular tachycardia (VT) is important in the clinical diagnosis and treatment of arrhythmias in heart failure (HF) patients. This study investigated the ability of the three-dimensional cardiac electrical imaging (3DCEI) technique for characterizing the activation patterns of spontaneously occurring and norepinephrine (NE)-induced VTs in a newly developed arrhythmogenic canine model of nonischemic HF. HF was induced by aortic insufficiency followed by aortic constriction in three canines. Up to 128 body-surface ECGs were measured simultaneously with bipolar recordings from up to 232 intramural sites in a closed-chest condition. Data analysis was performed on the spontaneously occurring VTs (n=4) and the NE-induced nonsustained VTs (n=8) in HF canines. Both spontaneously occurring and NE-induced nonsustained VTs initiated by a focal mechanism primarily from the subendocardium, but occasionally from the subepicardium of left ventricle. Most focal initiation sites were located at apex, right ventricular outflow tract, and left lateral wall. The NE-induced VTs were longer, more rapid, and had more focal sites than the spontaneously occurring VTs. Good correlation was obtained between imaged activation sequence and direct measurements (averaged correlation coefficient of ∼0.70 over 135 VT beats). The reconstructed initiation sites were ∼10 mm from measured initiation sites, suggesting good localization in such a large animal model with cardiac size similar to a human. Both spontaneously occurring and NE-induced nonsustained VTs had focal initiation in this canine model of nonischemic HF. 3DCEI is feasible to image the activation sequence and help define arrhythmia mechanism of nonischemic HF-associated VTs. Copyright © 2015 the American Physiological Society.

  19. Digital Sequences and a Time Reversal-Based Impact Region Imaging and Localization Method

    Science.gov (United States)

    Qiu, Lei; Yuan, Shenfang; Mei, Hanfei; Qian, Weifeng

    2013-01-01

    To reduce time and cost of damage inspection, on-line impact monitoring of aircraft composite structures is needed. A digital monitor based on an array of piezoelectric transducers (PZTs) is developed to record the impact region of impacts on-line. It is small in size, lightweight and has low power consumption, but there are two problems with the impact alarm region localization method of the digital monitor at the current stage. The first one is that the accuracy rate of the impact alarm region localization is low, especially on complex composite structures. The second problem is that the area of impact alarm region is large when a large scale structure is monitored and the number of PZTs is limited which increases the time and cost of damage inspections. To solve the two problems, an impact alarm region imaging and localization method based on digital sequences and time reversal is proposed. In this method, the frequency band of impact response signals is estimated based on the digital sequences first. Then, characteristic signals of impact response signals are constructed by sinusoidal modulation signals. Finally, the phase synthesis time reversal impact imaging method is adopted to obtain the impact region image. Depending on the image, an error ellipse is generated to give out the final impact alarm region. A validation experiment is implemented on a complex composite wing box of a real aircraft. The validation results show that the accuracy rate of impact alarm region localization is approximately 100%. The area of impact alarm region can be reduced and the number of PZTs needed to cover the same impact monitoring region is reduced by more than a half. PMID:24084123

  20. Superresolution Imaging Using Resonant Multiples and Plane-wave Migration Velocity Analysis

    KAUST Repository

    Guo, Bowen

    2017-08-28

    Seismic imaging is a technique that uses seismic echoes to map and detect underground geological structures. The conventional seismic image has the resolution limit of λ/2, where λ is the wavelength associated with the seismic waves propagating in the subsurface. To exceed this resolution limit, this thesis develops a new imaging method using resonant multiples, which produces superresolution images with twice or even more the spatial resolution compared to the conventional primary reflection image. A resonant multiple is defined as a seismic reflection that revisits the same subsurface location along coincident reflection raypath. This reverberated raypath is the reason for superresolution imaging because it increases the differences in reflection times associated with subtle changes in the spatial location of the reflector. For the practical implementation of superresolution imaging, I develop a post-stack migration technique that first enhances the signal-to-noise ratios (SNRs) of resonant multiples by a moveout-correction stacking method, and then migrates the post-stacked resonant multiples with the associated Kirchhoff or wave-equation migration formula. I show with synthetic and field data examples that the first-order resonant multiple image has about twice the spatial resolution compared to the primary reflection image. Besides resolution, the correct estimate of the subsurface velocity is crucial for determining the correct depth of reflectors. Towards this goal, wave-equation migration velocity analysis (WEMVA) is an image-domain method which inverts for the velocity model that maximizes the similarity of common image gathers (CIGs). Conventional WEMVA based on subsurface-offset, angle domain or time-lag CIGs requires significant computational and memory resources because it computes higher dimensional migration images in the extended image domain. To mitigate this problem, I present a new WEMVA method using plane-wave CIGs. Plane-wave CIGs reduce the

  1. Impairment in explicit visuomotor sequence learning is related to loss of microstructural integrity of the corpus callosum in multiple sclerosis patients with minimal disability.

    Science.gov (United States)

    Bonzano, L; Tacchino, A; Roccatagliata, L; Sormani, M P; Mancardi, G L; Bove, M

    2011-07-15

    Sequence learning can be investigated by serial reaction-time (SRT) paradigms. Explicit learning occurs when subjects have to recognize a test sequence and has been shown to activate the frontoparietal network in both contralateral and ipsilateral hemispheres. Thus, the left and right superior longitudinal fasciculi (SLF), connecting the intra-hemispheric frontoparietal circuits, could have a role in explicit unimanual visuomotor learning. Also, as both hemispheres are involved, we could hypothesize that the corpus callosum (CC) has a role in this process. Pathological damage in both SLF and CC has been detected in patients with Multiple Sclerosis (PwMS), and microstructural alterations can be quantified by Diffusion Tensor Imaging (DTI). In light of these findings, we inquired whether PwMS with minimal disability showed impairments in explicit visuomotor sequence learning and whether this could be due to loss of white matter integrity in these intra- and inter-hemispheric white matter pathways. Thus, we combined DTI analysis with a modified version of SRT task based on finger opposition movements in a group of PwMS with minimal disability. We found that the performance in explicit sequence learning was significantly reduced in these patients with respect to healthy subjects; the amount of sequence-specific learning was found to be more strongly correlated with fractional anisotropy (FA) in the CC (r=0.93) than in the left (r=0.28) and right SLF (r=0.27) (p for interaction=0.005 and 0.04 respectively). This finding suggests that an inter-hemispheric information exchange between the homologous areas is required to successfully accomplish the task and indirectly supports the role of the right (ipsilateral) hemisphere in explicit visuomotor learning. On the other hand, we found no significant correlation of the FA in the CC and in the SLFs with nonspecific learning (assessed when stimuli are randomly presented), supporting the hypothesis that inter

  2. Low-dose multiple-information retrieval algorithm for X-ray grating-based imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Huang Zhifeng; Chen Zhiqiang; Zhang Li; Jiang Xiaolei; Kang Kejun; Yin Hongxia; Wang Zhenchang; Stampanoni, Marco

    2011-01-01

    The present work proposes a low dose information retrieval algorithm for X-ray grating-based multiple-information imaging (GB-MII) method, which can retrieve the attenuation, refraction and scattering information of samples by only three images. This algorithm aims at reducing the exposure time and the doses delivered to the sample. The multiple-information retrieval problem in GB-MII is solved by transforming a nonlinear equations set to a linear equations and adopting the nature of the trigonometric functions. The proposed algorithm is validated by experiments both on conventional X-ray source and synchrotron X-ray source, and compared with the traditional multiple-image-based retrieval algorithm. The experimental results show that our algorithm is comparable with the traditional retrieval algorithm and especially suitable for high Signal-to-Noise system.

  3. The genealogy of sequences containing multiple sites subject to strong selection in a subdivided population.

    Science.gov (United States)

    Nordborg, Magnus; Innan, Hideki

    2003-03-01

    A stochastic model for the genealogy of a sample of recombining sequences containing one or more sites subject to selection in a subdivided population is described. Selection is incorporated by dividing the population into allelic classes and then conditioning on the past sizes of these classes. The past allele frequencies at the selected sites are thus treated as parameters rather than as random variables. The purpose of the model is not to investigate the dynamics of selection, but to investigate effects of linkage to the selected sites on the genealogy of the surrounding chromosomal region. This approach is useful for modeling strong selection, when it is natural to parameterize the past allele frequencies at the selected sites. Several models of strong balancing selection are used as examples, and the effects on the pattern of neutral polymorphism in the chromosomal region are discussed. We focus in particular on the statistical power to detect balancing selection when it is present.

  4. Sequencing of disease-modifying therapies for relapsing-remitting multiple sclerosis: a theoretical approach to optimizing treatment.

    Science.gov (United States)

    Grand'Maison, Francois; Yeung, Michael; Morrow, Sarah A; Lee, Liesly; Emond, Francois; Ward, Brian J; Laneuville, Pierre; Schecter, Robyn

    2018-04-18

    Multiple sclerosis (MS) is a chronic disease which usually begins in young adulthood and is a lifelong condition. Individuals with MS experience physical and cognitive disability resulting from inflammation and demyelination in the central nervous system. Over the past decade, several disease-modifying therapies (DMTs) have been approved for the management of relapsing-remitting MS (RRMS), which is the most prevalent phenotype. The chronic nature of the disease and the multiple treatment options make benefit-risk-based sequencing of therapy essential to ensure optimal care. The efficacy and short- and long-term risks of treatment differ for each DMT due to their different mechanism of action on the immune system. While transitioning between DMTs, in addition to immune system effects, factors such as age, disease duration and severity, disability status, monitoring requirements, preference for the route of administration, and family planning play an important role. Determining a treatment strategy is therefore challenging as it requires careful consideration of the differences in efficacy, safety and tolerability, while at the same time minimizing risks of immune modulation. In this review, we discuss a sequencing approach for treating RRMS, with importance given to the long-term risks and individual preference when devising a treatment plan. Evidence-based strategies to counter breakthrough disease are also addressed.

  5. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  6. SPIO-enhanced MR imaging for HCC detection in cirrhotic patient : comparison of various techniques for optimal sequence selection

    International Nuclear Information System (INIS)

    Kim, In Hwan; Lee, Jeong Min; Kwak, Hyo Sung; Kim, Chong Soo; Yu, Hee Chul; Kim, Tae Kon; Lee Soo Tiek

    2000-01-01

    To compare the efficacy of breathhold and non-breathhold sequences in the detection of hepatocellular carcinoma (HCC) in cirrhotic patients using superparamagnetic iron oxide (SPIO)-enhanced MR imaging, and to determine the optimal sequence combination. By means of unenhanced and iron-oxide-enhanced MRI, 29 patients with 49 nodular HCCs were evaluated for the presence of HCC nodules. Twenty-one were male and eight were female, and their ages ranged from 38 to 71 (mean, 56) years. Eight different MR sequences were used, including four non-breath-hold sequences and four breath-hold, and images were obtained before and after the administration of SPIO particles. Non-breath-hold sequences included T2-, proton density-weighted SE, and TSE imaging, while breath-hold sequences comprised T1-weighted fast low-angle shot (T1w FLASH), half-Fourier acquisition single shot turbo spine echo (HASTE), T2-weighted fast imaging with steady-state free precession (T2 * wFISP) and T2-weighted breath-hold TSE (T2wBHTSE). Image analysis involved both quantitative and qualitative analysis. The quantitative parameters calculated were signal-to noise (S/N) ratios for livers and tumors, contrast to noise (C/N) ratios for tumors seen on precontrast and postcontrast images, and percentage of signal intensity loss (PSIL) after SPIO injection. Images were analysed qualitatively in terms of image artifacts and lesion conspicuity, and prior to calculating sensitivity, the number of lesions detected using various pulse sequences were counted. SPIO had a marked effect on liver S/N ratio but a minimal effect on tumor S/N ratio. PSIL was best in T2 * wFISP images, while T2wSE images showed the second-best results (p less than 0.05). Tumor-to-liver C/N values were also highest with T2 * wFISP, while T2wTSE and HASTE images were next. Qualitative study showed that non-breath hold images and FISP were better than breath hold images in terms of lesion conspicuity. The latter, however, were much better

  7. Spatio-temporal Hotelling observer for signal detection from image sequences.

    Science.gov (United States)

    Caucci, Luca; Barrett, Harrison H; Rodriguez, Jeffrey J

    2009-06-22

    Detection of signals in noisy images is necessary in many applications, including astronomy and medical imaging. The optimal linear observer for performing a detection task, called the Hotelling observer in the medical literature, can be regarded as a generalization of the familiar prewhitening matched filter. Performance on the detection task is limited by randomness in the image data, which stems from randomness in the object, randomness in the imaging system, and randomness in the detector outputs due to photon and readout noise, and the Hotelling observer accounts for all of these effects in an optimal way. If multiple temporal frames of images are acquired, the resulting data set is a spatio-temporal random process, and the Hotelling observer becomes a spatio-temporal linear operator. This paper discusses the theory of the spatio-temporal Hotelling observer and estimation of the required spatio-temporal covariance matrices. It also presents a parallel implementation of the observer on a cluster of Sony PLAYSTATION 3 gaming consoles. As an example, we consider the use of the spatio-temporal Hotelling observer for exoplanet detection.

  8. On the Usage of GPUs for Efficient Motion Estimation in Medical Image Sequences

    Directory of Open Access Journals (Sweden)

    Jeyarajan Thiyagalingam

    2011-01-01

    Full Text Available Images are ubiquitous in biomedical applications from basic research to clinical practice. With the rapid increase in resolution, dimensionality of the images and the need for real-time performance in many applications, computational requirements demand proper exploitation of multicore architectures. Towards this, GPU-specific implementations of image analysis algorithms are particularly promising. In this paper, we investigate the mapping of an enhanced motion estimation algorithm to novel GPU-specific architectures, the resulting challenges and benefits therein. Using a database of three-dimensional image sequences, we show that the mapping leads to substantial performance gains, up to a factor of 60, and can provide near-real-time experience. We also show how architectural peculiarities of these devices can be best exploited in the benefit of algorithms, most specifically for addressing the challenges related to their access patterns and different memory configurations. Finally, we evaluate the performance of the algorithm on three different GPU architectures and perform a comprehensive analysis of the results.

  9. Exploring the effects of gravity on tongue motion using ultrasound image sequences

    Science.gov (United States)

    Stone, Maureen; Crouse, Ulla; Sutton, Marty

    2002-05-01

    Our goal in the research was to explore the effect that gravity had on the vocal-tract system by using ultrasound data collected in the upright and supine positions. All potential subjects were given an ultrasound pretest to determine whether they could repeat a series of 3-4 words precise enough to allow an accurate series of images to be collected. Out of these potential subjects, approximately 5-7 subjects were eventually used in the research. The method of collecting ultrasound data required the immobilization of the patient by restraining their neck in a custom fitted neck restraint. The neck restraint held an ultrasound transducer positioned at a critical angle underneath the patients' lower jawbone, which served to reduce errors and increase image resolution. To accurately analyze the series of images collected from ultrasound imaging, the surfaces of the tongue were digitized and tongue motion was time-aligned across the upright and supine sequences. Comparisons between the upright and supine data were then made by using L2 norms to determine averages and differences regarding the behavior between the two positions. Curves and locations of the maximum and minimum differences will be discussed.

  10. Design of a web portal for interdisciplinary image retrieval from multiple online image resources.

    Science.gov (United States)

    Kammerer, F J; Frankewitsch, T; Prokosch, H-U

    2009-01-01

    Images play an important role in medicine. Finding the desired images within the multitude of online image databases is a time-consuming and frustrating process. Existing websites do not meet all the requirements for an ideal learning environment for medical students. This work intends to establish a new web portal providing a centralized access point to a selected number of online image databases. A back-end system locates images on given websites and extracts relevant metadata. The images are indexed using UMLS and the MetaMap system provided by the US National Library of Medicine. Specially developed functions allow to create individual navigation structures. The front-end system suits the specific needs of medical students. A navigation structure consisting of several medical fields, university curricula and the ICD-10 was created. The images may be accessed via the given navigation structure or using different search functions. Cross-references are provided by the semantic relations of the UMLS. Over 25,000 images were identified and indexed. A pilot evaluation among medical students showed good first results concerning the acceptance of the developed navigation structures and search features. The integration of the images from different sources into the UMLS semantic network offers a quick and an easy-to-use learning environment.

  11. Retrieving clinically relevant diabetic retinopathy images using a multi-class multiple-instance framework

    Science.gov (United States)

    Chandakkar, Parag S.; Venkatesan, Ragav; Li, Baoxin

    2013-02-01

    Diabetic retinopathy (DR) is a vision-threatening complication from diabetes mellitus, a medical condition that is rising globally. Unfortunately, many patients are unaware of this complication because of absence of symptoms. Regular screening of DR is necessary to detect the condition for timely treatment. Content-based image retrieval, using archived and diagnosed fundus (retinal) camera DR images can improve screening efficiency of DR. This content-based image retrieval study focuses on two DR clinical findings, microaneurysm and neovascularization, which are clinical signs of non-proliferative and proliferative diabetic retinopathy. The authors propose a multi-class multiple-instance image retrieval framework which deploys a modified color correlogram and statistics of steerable Gaussian Filter responses, for retrieving clinically relevant images from a database of DR fundus image database.

  12. X-ray luminescence computed tomography imaging via multiple intensity weighted narrow beam irradiation

    Science.gov (United States)

    Feng, Bo; Gao, Feng; Zhao, Huijuan; Zhang, Limin; Li, Jiao; Zhou, Zhongxing

    2018-02-01

    The purpose of this work is to introduce and study a novel x-ray beam irradiation pattern for X-ray Luminescence Computed Tomography (XLCT), termed multiple intensity-weighted narrow-beam irradiation. The proposed XLCT imaging method is studied through simulations of x-ray and diffuse lights propagation. The emitted optical photons from X-ray excitable nanophosphors were collected by optical fiber bundles from the right-side surface of the phantom. The implementation of image reconstruction is based on the simulated measurements from 6 or 12 angular projections in terms of 3 or 5 x-ray beams scanning mode. The proposed XLCT imaging method is compared against the constant intensity weighted narrow-beam XLCT. From the reconstructed XLCT images, we found that the Dice similarity and quantitative ratio of targets have a certain degree of improvement. The results demonstrated that the proposed method can offer simultaneously high image quality and fast image acquisition.

  13. A Low-Complexity Algorithm for Static Background Estimation from Cluttered Image Sequences in Surveillance Contexts

    Directory of Open Access Journals (Sweden)

    Reddy Vikas

    2011-01-01

    Full Text Available Abstract For the purposes of foreground estimation, the true background model is unavailable in many practical circumstances and needs to be estimated from cluttered image sequences. We propose a sequential technique for static background estimation in such conditions, with low computational and memory requirements. Image sequences are analysed on a block-by-block basis. For each block location a representative set is maintained which contains distinct blocks obtained along its temporal line. The background estimation is carried out in a Markov Random Field framework, where the optimal labelling solution is computed using iterated conditional modes. The clique potentials are computed based on the combined frequency response of the candidate block and its neighbourhood. It is assumed that the most appropriate block results in the smoothest response, indirectly enforcing the spatial continuity of structures within a scene. Experiments on real-life surveillance videos demonstrate that the proposed method obtains considerably better background estimates (both qualitatively and quantitatively than median filtering and the recently proposed "intervals of stable intensity" method. Further experiments on the Wallflower dataset suggest that the combination of the proposed method with a foreground segmentation algorithm results in improved foreground segmentation.

  14. MR imaging of multiple sclerosis in patients with negative cerebrospinal fluid

    International Nuclear Information System (INIS)

    Dooms, G.C.; Mathurin, P.; Cornelis, G.; Laterre, E.C.; Demeure, R.

    1986-01-01

    A prospective study was performed to assess the value of MR imaging for detecting demyelinating disease of the brain in 50 patients with clinically suspected multiple sclerosis but negative cerebrospinal fluid (CSF). The MR imaging examinations were performed with a superconducting magnet (Philips Gyroscan S15) operating at 0.5T. A multisection, double spin-echo technique was used in all cases (TR = 2,100 msec, TE = 50 and 100 msec). No abnormality was demonstrated in eight patients. In the others, lesions were usually located in the periventricular white matter (rounded masses and/or high signal intensity bands along the lateral ventricles), the brain stem and thalami (12 patients), and the cerebellum (6 patients). In conclusion, MR imaging appears to be an exquisite imaging modality for confirmation of clinically suspected multiple sclerosis in patients with negative CSF. However, it must include examination of the spinal cord when the brain examination is negative

  15. COLOR IMAGE RETRIEVAL BASED ON FEATURE FUSION THROUGH MULTIPLE LINEAR REGRESSION ANALYSIS

    Directory of Open Access Journals (Sweden)

    K. Seetharaman

    2015-08-01

    Full Text Available This paper proposes a novel technique based on feature fusion using multiple linear regression analysis, and the least-square estimation method is employed to estimate the parameters. The given input query image is segmented into various regions according to the structure of the image. The color and texture features are extracted on each region of the query image, and the features are fused together using the multiple linear regression model. The estimated parameters of the model, which is modeled based on the features, are formed as a vector called a feature vector. The Canberra distance measure is adopted to compare the feature vectors of the query and target images. The F-measure is applied to evaluate the performance of the proposed technique. The obtained results expose that the proposed technique is comparable to the other existing techniques.

  16. Coseismic deformation pattern of the Emilia 2012 seismic sequence imaged by Radarsat-1 interferometry

    Directory of Open Access Journals (Sweden)

    Christian Bignami

    2012-10-01

    Full Text Available On May 20 and 29, 2012, two earthquakes of magnitudes 5.9 and 5.8 (Mw, respectively, and their aftershock sequences hit the central Po Plain (Italy, about 40 km north of Bologna. More than 2,000 sizable aftershocks were recorded by the Isti-tuto Nazionale di Geofisica e Vulcanologia (INGV; National Institute of Geophysics and Volcanology National Seismic Network (http://iside.rm.ingv.it/. The sequence was generated by pure compressional faulting over blind thrusts of the western Ferrara Arc, and it involved a 50-km-long stretch of this buried outer front of the northern Apennines. The focal mechanisms of the larger shocks agree with available structural data and with present-day tectonic stress indicators, which show locally a maximum horizontal stress oriented ca. N-S; i.e. oriented perpendicular to the main structural trends. Most of the sequence occurred between 1 km and 12 km in depth, above the local basal detachment of the outer thrust fronts of the northern Apennines. We measured the surface displacement patterns associated with the mainshocks and some of the larger aftershocks (some of which had Mw >5.0 by applying the Interferometric Synthetic Aperture Radar (InSAR technique to a pair of C-Band Radarsat-1 images. We then used the coseismic motions detected over the epicentral region as input information, to obtain the best-fit model fault for the two largest shocks. […

  17. A probabilistic cell model in background corrected image sequences for single cell analysis

    Directory of Open Access Journals (Sweden)

    Fieguth Paul

    2010-10-01

    Full Text Available Abstract Background Methods of manual cell localization and outlining are so onerous that automated tracking methods would seem mandatory for handling huge image sequences, nevertheless manual tracking is, astonishingly, still widely practiced in areas such as cell biology which are outside the influence of most image processing research. The goal of our research is to address this gap by developing automated methods of cell tracking, localization, and segmentation. Since even an optimal frame-to-frame association method cannot compensate and recover from poor detection, it is clear that the quality of cell tracking depends on the quality of cell detection within each frame. Methods Cell detection performs poorly where the background is not uniform and includes temporal illumination variations, spatial non-uniformities, and stationary objects such as well boundaries (which confine the cells under study. To improve cell detection, the signal to noise ratio of the input image can be increased via accurate background estimation. In this paper we investigate background estimation, for the purpose of cell detection. We propose a cell model and a method for background estimation, driven by the proposed cell model, such that well structure can be identified, and explicitly rejected, when estimating the background. Results The resulting background-removed images have fewer artifacts and allow cells to be localized and detected more reliably. The experimental results generated by applying the proposed method to different Hematopoietic Stem Cell (HSC image sequences are quite promising. Conclusion The understanding of cell behavior relies on precise information about the temporal dynamics and spatial distribution of cells. Such information may play a key role in disease research and regenerative medicine, so automated methods for observation and measurement of cells from microscopic images are in high demand. The proposed method in this paper is capable

  18. Quantitative genome re-sequencing defines multiple mutations conferring chloroquine resistance in rodent malaria

    Science.gov (United States)

    2012-01-01

    Background Drug resistance in the malaria parasite Plasmodium falciparum severely compromises the treatment and control of malaria. A knowledge of the critical mutations conferring resistance to particular drugs is important in understanding modes of drug action and mechanisms of resistances. They are required to design better therapies and limit drug resistance. A mutation in the gene (pfcrt) encoding a membrane transporter has been identified as a principal determinant of chloroquine resistance in P. falciparum, but we lack a full account of higher level chloroquine resistance. Furthermore, the determinants of resistance in the other major human malaria parasite, P. vivax, are not known. To address these questions, we investigated the genetic basis of chloroquine resistance in an isogenic lineage of rodent malaria parasite P. chabaudi in which high level resistance to chloroquine has been progressively selected under laboratory conditions. Results Loci containing the critical genes were mapped by Linkage Group Selection, using a genetic cross between the high-level chloroquine-resistant mutant and a genetically distinct sensitive strain. A novel high-resolution quantitative whole-genome re-sequencing approach was used to reveal three regions of selection on chr11, chr03 and chr02 that appear progressively at increasing drug doses on three chromosomes. Whole-genome sequencing of the chloroquine-resistant parent identified just four point mutations in different genes on these chromosomes. Three mutations are located at the foci of the selection valleys and are therefore predicted to confer different levels of chloroquine resistance. The critical mutation conferring the first level of chloroquine resistance is found in aat1, a putative aminoacid transporter. Conclusions Quantitative trait loci conferring selectable phenotypes, such as drug resistance, can be mapped directly using progressive genome-wide linkage group selection. Quantitative genome-wide short

  19. Multiple-Targeted Graphene-based Nanocarrier for Intracellular Imaging of mRNAs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ying; Li, Zhaohui; Liu, Misha; Hu, Dehong; Lin, Yuehe; Li, Jinghong

    2017-08-29

    Simultaneous detection and imaging of multiple intracellular messenger RNA (mRNAs) hold great significant for early cancer diagnostics and preventive medicine development. Herein, we propose a multiple-targeted graphene oxide (GO) nanocarrier that can simultaneously detect and image different type mRNAs in living cells. First of all, in vitro detection of multiple targets have been realized successfully based on the multiple-targeted GO nanocarrier with linear relationship ranging from 3 nM to 200 nM, as well as sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) mRNA and 2.45 nM for β-actin mRNA. Additionally, this nanosensing platform composed of fluorescent labeled single strand DNA probes and GO nanocarrier can identify Mn-SOD mRNA and endogenous mRNA of β-actin in living cancer cells, showing rapid response, high specificity, nuclease stability, and good biocompatibility during the cell imaging. Thirdly, changes of the expression levels of mRNA in living cells before or after the drug treatment can be monitored successfully. By using multiple ssDNA as probes and GO nanocarrier as the cellular delivery cargo, the proposed simultaneous multiple-targeted sensing platform will be of great potential as a powerful tool for intracellular trafficking process from basic research to clinical diagnosis.

  20. Syndrome disintegration: Exome sequencing reveals that Fitzsimmons syndrome is a co-occurrence of multiple events.

    Science.gov (United States)

    Armour, Christine M; Smith, Amanda; Hartley, Taila; Chardon, Jodi Warman; Sawyer, Sarah; Schwartzentruber, Jeremy; Hennekam, Raoul; Majewski, Jacek; Bulman, Dennis E; Suri, Mohnish; Boycott, Kym M

    2016-07-01

    In 1987 Fitzsimmons and Guilbert described identical male twins with progressive spastic paraplegia, brachydactyly with cone shaped epiphyses, short stature, dysarthria, and "low-normal" intelligence. In subsequent years, four other patients, including one set of female identical twins, a single female child, and a single male individual were described with the same features, and the eponym Fitzsimmons syndrome was adopted (OMIM #270710). We performed exome analysis of the patient described in 2009, and one of the original twins from 1987, the only patients available from the literature. No single genetic etiology exists that explains Fitzsimmons syndrome; however, multiple different genetic causes were identified. Specifically, the twins described by Fitzsimmons had heterozygous mutations in the SACS gene, the gene responsible for autosomal recessive spastic ataxia of Charlevoix Saguenay (ARSACS), as well as a heterozygous mutation in the TRPS1, the gene responsible in Trichorhinophalangeal syndrome type 1 (TRPS1 type 1) which includes brachydactyly as a feature. A TBL1XR1 mutation was identified in the patient described in 2009 as contributing to his cognitive impairment and autistic features with no genetic cause identified for his spasticity or brachydactyly. The findings show that these individuals have multiple different etiologies giving rise to a similar phenotype, and that "Fitzsimmons syndrome" is in fact not one single syndrome. Over time, we anticipate that continued careful phenotyping with concomitant genome-wide analysis will continue to identify the causes of many rare syndromes, but it will also highlight that previously delineated clinical entities are, in fact, not syndromes at all. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Diffusion-weighted imaging of the rat pelvis using 3D water-excitation MP-RAGE MR sequence

    International Nuclear Information System (INIS)

    Numano, Tomokazu; Homma, Kazuhiro; Hyodo, Koji; Nitta, Naotaka; Iwasaki, Nobuaki

    2008-01-01

    We developed a novel technique for fat-saturated, 3-dimensional (3D) diffusion-weighted (DW) magnetic resonance (MR) imaging sequencing based upon the 3D magnetization-prepared, rapid gradient-echo (3D-MP-RAGE) method. We saturated fat using 2 techniques, chemical shift selective (CHESS; FatSat)-3D-DWI sequence versus water excitation (WE)-3D-DWI method, then compared the 2 sequences in terms of degree of fat suppression. In preparing the FatSat-3D-DWI sequence, we used a ''CHESS-90deg radiofrequency (RF)-motion probing gradient (MPG)-180deg RFMPG-90deg RF'' pulse-train, to sensitize the magnetization to fat-saturated diffusion. In contrast, in the WE-3D-DWI sequence, we selected a RAGE-excitation pulse with a binominal-pulse 1-1 or 1-2-1 for water-excited (fat-saturated) diffusion imaging. Experimental results in a phantom confirmed the effects of diffusion weighting and of fat saturation. Fat saturation was much better in the WE-3D-DWI sequence than the CHESS-3D-DWI sequence. From results from animal (rat pelvis) experiments using WE-3D-DWI, we obtained fat-saturated DWI. This sequence was useful for in vivo imaging. (author)

  2. Development of 99mTc imaging method using multiple imaging plates for reduction of patient's dose

    International Nuclear Information System (INIS)

    Ito, Shigeki; Nishizawa, Kunihide; Ariga, Eiji; Saze, Takuya

    2008-01-01

    A system for taking static thyroid 99m Tc images was devised by using multiple imaging plates (IPs) and a low energy high resolution collimator. Sensitivity was represented by using lower detection limits (LDL). The sensitivity and resolution of IP systems using a collimator and 9 IPs were determined by using a 20 ml thyroid phantom, and compared with the sensitivity of gamma cameras. The sensitivity of the IP systems increased in proportion to the number of IPs. The sensitivity and resolution of a probe using 9 IPs and a high resolution collimator were equivalent to or superior to the gamma camera for taking static thyroid 99m Tc images. IP systems can be applied clinically as static nuclear imaging devices as same as a gamma camera. (author)

  3. A Single Electrochemical Probe Used for Analysis of Multiple Nucleic Acid Sequences

    Science.gov (United States)

    Mills, Dawn M.; Calvo-Marzal, Percy; Pinzon, Jeffer M.; Armas, Stephanie; Kolpashchikov, Dmitry M.; Chumbimuni-Torres, Karin Y.

    2017-01-01

    Electrochemical hybridization sensors have been explored extensively for analysis of specific nucleic acids. However, commercialization of the platform is hindered by the need for attachment of separate oligonucleotide probes complementary to a RNA or DNA target to an electrode’s surface. Here we demonstrate that a single probe can be used to analyze several nucleic acid targets with high selectivity and low cost. The universal electrochemical four-way junction (4J)-forming (UE4J) sensor consists of a universal DNA stem-loop (USL) probe attached to the electrode’s surface and two adaptor strands (m and f) which hybridize to the USL probe and the analyte to form a 4J associate. The m adaptor strand was conjugated with a methylene blue redox marker for signal ON sensing and monitored using square wave voltammetry. We demonstrated that a single sensor can be used for detection of several different DNA/RNA sequences and can be regenerated in 30 seconds by a simple water rinse. The UE4J sensor enables a high selectivity by recognition of a single base substitution, even at room temperature. The UE4J sensor opens a venue for a re-useable universal platform that can be adopted at low cost for the analysis of DNA or RNA targets. PMID:29371782

  4. Sequence-based analysis of the bacterial and fungal compositions of multiple kombucha (tea fungus) samples.

    Science.gov (United States)

    Marsh, Alan J; O'Sullivan, Orla; Hill, Colin; Ross, R Paul; Cotter, Paul D

    2014-04-01

    Kombucha is a sweetened tea beverage that, as a consequence of fermentation, contains ethanol, carbon dioxide, a high concentration of acid (gluconic, acetic and lactic) as well as a number of other metabolites and is thought to contain a number of health-promoting components. The sucrose-tea solution is fermented by a symbiosis of bacteria and yeast embedded within a cellulosic pellicle, which forms a floating mat in the tea, and generates a new layer with each