WorldWideScience

Sample records for multiple exposure ccd

  1. Development of Multiple-Element Flame Emission Spectrometer Using CCD Detection

    Science.gov (United States)

    Seney, Caryn S.; Sinclair, Karen V.; Bright, Robin M.; Momoh, Paul O.; Bozeman, Amelia D.

    2005-01-01

    The full wavelength coverage of charge coupled device (CCD) detector when coupled with an echelle spectrography, the system allows for simultaneously multiple element spectroscopy to be performed. The multiple-element flame spectrometer was built and characterized through the analysis of environmentally significant elements such as Ca, K, Na, Cu,…

  2. CCD Photometry Using Multiple Comparison Stars

    Directory of Open Access Journals (Sweden)

    Yonggi Kim

    2004-09-01

    Full Text Available The accuracy of CCD observations obtained at the Korean 1.8 m telescope has been studied. Seventeen comparison stars in the vicinity of the cataclysmic variable BG CMi have been measured. The ``artificial" star has been used instead of the ``control" star, what made possible to increase accuracy estimates by a factor of 1.3-2.1 times for ``good" and ``cloudy" nights, respectively. The algorithm of iterative determination of accuracy and weights of few comparison stars contributing to the artificial star, has been presented. The accuracy estimates for 13-mag stars are around 0.002 m mag for exposure times of 30 sec.

  3. A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam

    CERN Document Server

    Suzuki, M; Kumasaka, T; Sato, K; Toyokawa, H; Aries, I F; Jerram, P A; Ueki, T

    1999-01-01

    A 4x4 array structure of 16 identical CCD X-ray detector modules, called the multiple CCD X-ray detector system (MCCDX), was submitted to its first synchrotron radiation experiment at the protein crystallography station of the RIKEN beamline (BL45XU) at the SPring-8 facility. An X-ray diffraction pattern of cholesterol powder was specifically taken in order to investigate the overall system performance.

  4. Contribution of the Chromosomal ccdAB Operon to Bacterial Drug Tolerance.

    Science.gov (United States)

    Gupta, Kritika; Tripathi, Arti; Sahu, Alishan; Varadarajan, Raghavan

    2017-10-01

    One of the first identified and best-studied toxin-antitoxin (TA) systems in Escherichia coli is the F-plasmid-based CcdAB system. This system is involved in plasmid maintenance through postsegregational killing. More recently, ccdAB homologs have been found on the chromosome, including in pathogenic strains of E. coli and other bacteria. However, the functional role of chromosomal ccdAB genes, if any, has remained unclear. We show that both the native ccd operon of the E. coli O157 strain ( ccd O157 ) and the ccd operon from the F plasmid ( ccd F ), when inserted on the E. coli chromosome, lead to protection from cell death under multiple antibiotic stress conditions through formation of persisters, with the O157 operon showing higher protection. While the plasmid-encoded CcdB toxin is a potent gyrase inhibitor and leads to bacterial cell death even under fully repressed conditions, the chromosomally encoded toxin leads to growth inhibition, except at high expression levels, where some cell death is seen. This was further confirmed by transiently activating the chromosomal ccd operon through overexpression of an active-site inactive mutant of F-plasmid-encoded CcdB. Both the ccd F and ccd O157 operons may share common mechanisms for activation under stress conditions, eventually leading to multidrug-tolerant persister cells. This study clearly demonstrates an important role for chromosomal ccd systems in bacterial persistence. IMPORTANCE A large number of free-living and pathogenic bacteria are known to harbor multiple toxin-antitoxin systems, on plasmids as well as on chromosomes. The F-plasmid CcdAB system has been extensively studied and is known to be involved in plasmid maintenance. However, little is known about the function of its chromosomal counterpart, found in several pathogenic E. coli strains. We show that the native chromosomal ccd operon of the E. coli O157 strain is involved in drug tolerance and confers protection from cell death under multiple

  5. STIS-01 CCD Functional

    Science.gov (United States)

    Valenti, Jeff

    2001-07-01

    This activity measures the baseline performance and commandability of the CCD subsystem. Only primary amplifier D is used. Bias, Dark, and Flat Field exposures are taken in order to measure read noise, dark current, CTE, and gain. Numerous bias frames are taken to permit construction of "superbias" frames in which the effects of read noise have been rendered negligible. Dark exposures are made outside the SAA. Full frame and binned observations are made, with binning factors of 1x1 and 2x2. Finally, tungsten lamp exposures are taken through narrow slits to confirm the slit positions in the current database. All exposures are internals. This is a reincarnation of SM3A proposal 8502 with some unnecessary tests removed from the program.

  6. Image differencing using masked CCD

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.; Webber, C.J. St. J.

    1987-01-01

    A charge coupled device has some of its ''pixels'' masked by a material which is opaque to the radiation to which the device is to be exposed, each masked region being employed as a storage zone into which the charge pattern from the unmasked pixels can be transferred to enable a subsequent charge pattern to be established on further exposure of the unmasked pixels. The components of the resulting video signal corresponding to the respective charge patterns read-out from the CCD are subtracted to produce a video signal corresponding to the difference between the two images which formed the respective charge patterns. Alternate rows of pixels may be masked, or chequer-board pattern masking may be employed. In an X-ray imaging system the CCD is coupled to image intensifying and converting means. (author)

  7. Micrometer and CCD measurements of double stars (Series 51

    Directory of Open Access Journals (Sweden)

    Popović G.M.

    1998-01-01

    Full Text Available 36 micrometric measurements of 20 double or multiple systems carried out with the Zeiss 65/1055 cm Refractor of Belgrade Observatory are communicated. Also 35 CCD measurements of 15 double or multiple systems are included.

  8. A self triggered intensified Ccd (Stic)

    International Nuclear Information System (INIS)

    Charon, Y.; Laniece, P.; Bendali, M.

    1990-01-01

    We are developing a new device based on the results reported previously of the successfull coincidence detection of β- particles with a high spatial resolution [1]. The novelty of the device consists in triggering an intensified CCD, i.e. a CCD coupled to an image intensifier (II), by an electrical signal collected from the II itself. This is a suitable procedure for detecting with high efficiency and high resolution low light rare events. The trigger pulse is obtained from the secondary electrons produced by multiplication in a double microchannel plate (MCP) and collected on the aluminized layer protecting the phosphor screen in the II. Triggering efficiencies up to 80% has been already achieved

  9. CCD image sensor induced error in PIV applications

    Science.gov (United States)

    Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.

    2014-06-01

    The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.

  10. CCD image sensor induced error in PIV applications

    International Nuclear Information System (INIS)

    Legrand, M; Nogueira, J; Vargas, A A; Ventas, R; Rodríguez-Hidalgo, M C

    2014-01-01

    The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (∼0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described. (paper)

  11. A CCD portrait of Comet P/Tempel 2

    International Nuclear Information System (INIS)

    Jewitt, D.; Luu, J.

    1989-01-01

    The development of activity in Comet P/Tempel 2 is studied from aphelion (R = 4 AU) to perihelion (R = 1.4 AU) using extensive time-series CCD photometry and CCD spectra. The comet undergoes a profound morphological change at R of about 2-2.5 AU, from a bare nucleus at larger distances to an active comet supporting a coma of gas and dust. Cyclic photometric variations with the period T = 8.95 + or - 0.01 hr. are present at all R, and are attributed to the rotation of the nucleus at this period. The nucleus is prolate (axes a:b:c = 1.9:1:1), a property shared with other nuclei studied using CCD photometry. Novel results include a limit on the bulk density of the nucleus, rho above 300 kg/cu m, and a 20-A-resolution CCD spectrum of the nucleus. Spatially and temporally resolved photometry is used to study the effects of nucleus rotation on the coma. The coma does not share the dramatic photometric variations shown by the nucleus. It possesses a steep surface-brightness distribution, which is attributable to progressive destruction of the coma grains with increasing space exposure. 41 refs

  12. X-ray diagnostic study on the optimization of digital radiography in dentistry. Optimal exposure conditions for X-ray CCD sensor

    International Nuclear Information System (INIS)

    Hakata, Toshifumi

    2002-01-01

    The purpose of this research is to reduce the patient dose by optimization of irradiation conditions of an X-ray CCD sensor in intra-oral digital radiography. The X-ray diagnosis was divided into two, high quality-of-image diagnosis and low quality-of-image diagnosis, and it optimized by using the exposure of necessary minimum for each. The image quality of CCD was evaluated using the signal-to-noise ratio (SNR) in order to estimate the influence of irradiation conditions. The dose based on CCD maker setting value was set up so that the highest quality of image might be obtained mostly. In low quality-of-image diagnosis, even if it reduced the dose to 13.2% of standard irradiation, SNR was 40% and interpretation was possible. In high quality-of-image diagnosis, even if it reduces the dose to 49% of standard irradiation, SNR remained 80% and there were few differences of the image with a standard. A study of the digital X-ray examination taken at the dental clinic showed high quality-of-image diagnosis was 69% and low quality-of-image one was 31%. When this optimization was performed, it was presumed that reduction of about 62% of the dose is possible. (author)

  13. A New CCD Camera at the Molėtai Observatory

    Directory of Open Access Journals (Sweden)

    Zdanavičius J.

    2003-12-01

    Full Text Available The results of the first testing of a new CCD camera of the Molėtai Observatory are given. The linearity and the flat field corrections of good accuracy are determined by using shifted star field exposures.

  14. A programmable CCD driver circuit for multiphase CCD operation

    International Nuclear Information System (INIS)

    Ewin, A.J.; Reed, K.V.

    1989-01-01

    A programmable CCD driver circuit was designed to drive CCD's in multiphased modes. The purpose of the drive electronics was to operate developmental CCD imaging arrays for NASA's Moderate Resolution Imaging Spectrometer - Tiltable (MODIS-T). Five prototype arrays were designed. Valid's Graphics Editor (GED) was used to design the driver. With this driver design, any of the five arrays can be readout. Designing the driver with GED allowed functional simulation, timing verification, and certain packaging analyses to be done on the design before fabrication. The driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400 Kpixels/sec. Timing and packaging parameters were verified. the design uses 54 TTL component chips

  15. Advanced CCD camera developments

    Energy Technology Data Exchange (ETDEWEB)

    Condor, A. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Two charge coupled device (CCD) camera systems are introduced and discussed, describing briefly the hardware involved, and the data obtained in their various applications. The Advanced Development Group Defense Sciences Engineering Division has been actively designing, manufacturing, fielding state-of-the-art CCD camera systems for over a decade. These systems were originally developed for the nuclear test program to record data from underground nuclear tests. Today, new and interesting application for these systems have surfaced and development is continuing in the area of advanced CCD camera systems, with the new CCD camera that will allow experimenters to replace film for x-ray imaging at the JANUS, USP, and NOVA laser facilities.

  16. SlCCD7 controls strigolactone biosynthesis, shoot branching and mycorrhiza-induced apocarotenoid formation in tomato.

    NARCIS (Netherlands)

    Vogel, J.T.; Walter, M.H.; Giavalisco, P.; Lytovchenko, A.; Kohlen, W.; Charnikhova, T.; Simkin, A.J.; Goulet, C.; Strack, D.; Bouwmeester, H.J.; Fernie, A.R.; Klee, H.J.

    2010-01-01

    The regulation of shoot branching is an essential determinant of plant architecture, integrating multiple external and internal signals. One of the signaling pathways regulating branching involves the MAX (more axillary branches) genes. Two of the genes within this pathway, MAX3/CCD7 and MAX4/CCD8,

  17. Development of CCD Imaging System Using Thermoelectric Cooling Method

    Directory of Open Access Journals (Sweden)

    Youngsik Park

    2000-06-01

    Full Text Available We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E (768x512 pixels CCD chip,thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of -25deg. We employed an Uniblitz VS25S shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of -10deg, a linearity 99.9+/-0.1%, gain 4.24e-adu, and system noise is 25.3e- (rms. For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry (+/-0.01mag even though the CCD is not at 'conventional' cryogenic temperatures (140K. The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  18. High-resolution CCD imaging alternatives

    Science.gov (United States)

    Brown, D. L.; Acker, D. E.

    1992-08-01

    High resolution CCD color cameras have recently stimulated the interest of a large number of potential end-users for a wide range of practical applications. Real-time High Definition Television (HDTV) systems are now being used or considered for use in applications ranging from entertainment program origination through digital image storage to medical and scientific research. HDTV generation of electronic images offers significant cost and time-saving advantages over the use of film in such applications. Further in still image systems electronic image capture is faster and more efficient than conventional image scanners. The CCD still camera can capture 3-dimensional objects into the computing environment directly without having to shoot a picture on film develop it and then scan the image into a computer. 2. EXTENDING CCD TECHNOLOGY BEYOND BROADCAST Most standard production CCD sensor chips are made for broadcast-compatible systems. One popular CCD and the basis for this discussion offers arrays of roughly 750 x 580 picture elements (pixels) or a total array of approximately 435 pixels (see Fig. 1). FOR. A has developed a technique to increase the number of available pixels for a given image compared to that produced by the standard CCD itself. Using an inter-lined CCD with an overall spatial structure several times larger than the photo-sensitive sensor areas each of the CCD sensors is shifted in two dimensions in order to fill in spatial gaps between adjacent sensors.

  19. CCD Camera Lens Interface for Real-Time Theodolite Alignment

    Science.gov (United States)

    Wake, Shane; Scott, V. Stanley, III

    2012-01-01

    Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.

  20. Colony Collapse Disorder (CCD) and bee age impact honey bee pathophysiology.

    Science.gov (United States)

    vanEngelsdorp, Dennis; Traynor, Kirsten S; Andree, Michael; Lichtenberg, Elinor M; Chen, Yanping; Saegerman, Claude; Cox-Foster, Diana L

    2017-01-01

    Honey bee (Apis mellifera) colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD) and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions), and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees), we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence) and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and factors

  1. Colony Collapse Disorder (CCD and bee age impact honey bee pathophysiology.

    Directory of Open Access Journals (Sweden)

    Dennis vanEngelsdorp

    Full Text Available Honey bee (Apis mellifera colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions, and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees, we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and

  2. Performance of an area variable MOS varicap weighted programmable CCD transversal filter

    OpenAIRE

    Bhattacharyya, A.B.; Shankarnarayan, L.; Kapur, N.; Wallinga, Hans

    1981-01-01

    The performance of an electrically programmable CCD transversal filter (PTF) is presented in which tap-weight multiplication is performed by a novel and compact on chip voltage controlled area variable MOS varicap.

  3. Enhanced performance CCD output amplifier

    Science.gov (United States)

    Dunham, Mark E.; Morley, David W.

    1996-01-01

    A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

  4. A large area cooled-CCD detector for electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.; Andrews, H.N.; Raeburn, C.

    1994-01-01

    Large area cooled-CCDs are an excellent medium for (indirectly) recording electron images and electron diffraction patterns in real time and for use in electron tomography; real-time imaging is extremely useful in making rapid adjustments in the electron microscope. CCDs provide high sensitivity (useful for minimising dosage to radiation-sensitive biological specimen), good resolution, stable performance, excellent dynamic range and linearity and a reasonably fast readout.We have built an electron imaging device based on the EEV 1152 by 814 pixel CCD which is controlled from a unix based SUN Sparcstation operating under X-Windows. The incident 100 kV electrons are converted to visible light in a 0.5 mm thick YAG single crystal which is imaged through a lens on to the CCD.The CCD electronics is designed to be as flexible as possible and allows a wide variation in the readout speed to cater for the relatively fast application where readout noise is less critical and low readout noise applications where the extra few seconds of readout time are not significant. The CCD electronics is built in VME format which is controlled through a S-bus to VME driver. With two parallel channels of readout the whole image can be read out in similar 1 s (using the faster readout speed) with 16 bit precision and the image is displayed under X-Windows in a few seconds. The present readout works at 500 kHz and has a noise of similar 30 e rms per pixel. With a Peltier cooling device we can operate the CCD at similar -40 circle C which reduces the dark current adequately to allow exposures of up to several minutes. Several examples of patterns collected with the system on a Philips CM12 microscope will be presented. ((orig.))

  5. Crystallization of the C-terminal domain of the addiction antidote CcdA in complex with its toxin CcdB

    International Nuclear Information System (INIS)

    Buts, Lieven; De Jonge, Natalie; Loris, Remy; Wyns, Lode; Dao-Thi, Minh-Hoa

    2005-01-01

    The CcdA C-terminal domain was crystallized in complex with CcdB in two crystal forms that diffract to beyond 2.0 Å resolution. CcdA and CcdB are the antidote and toxin of the ccd addiction module of Escherichia coli plasmid F. The CcdA C-terminal domain (CcdA C36 ; 36 amino acids) was crystallized in complex with CcdB (dimer of 2 × 101 amino acids) in three different crystal forms, two of which diffract to high resolution. Form II belongs to space group P2 1 2 1 2 1 , with unit-cell parameters a = 37.6, b = 60.5, c = 83.8 Å and diffracts to 1.8 Å resolution. Form III belongs to space group P2 1 , with unit-cell parameters a = 41.0, b = 37.9, c = 69.6 Å, β = 96.9°, and diffracts to 1.9 Å resolution

  6. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  7. CCD research. [design, fabrication, and applications

    Science.gov (United States)

    Gassaway, J. D.

    1976-01-01

    The fundamental problems encountered in designing, fabricating, and applying CCD's are reviewed. Investigations are described and results and conclusions are given for the following: (1) the development of design analyses employing computer aided techniques and their application to the design of a grapped structure; (2) the role of CCD's in applications to electronic functions, in particular, signal processing; (3) extending the CCD to silicon films on sapphire (SOS); and (4) all aluminum transfer structure with low noise input-output circuits. Related work on CCD imaging devices is summarized.

  8. CCD and IR array controllers

    Science.gov (United States)

    Leach, Robert W.; Low, Frank J.

    2000-08-01

    A family of controllers has bene developed that is powerful and flexible enough to operate a wide range of CCD and IR focal plane arrays in a variety of ground-based applications. These include fast readout of small CCD and IR arrays for adaptive optics applications, slow readout of large CCD and IR mosaics, and single CCD and IR array operation at low background/low noise regimes as well as high background/high speed regimes. The CCD and IR controllers have a common digital core based on user- programmable digital signal processors that are used to generate the array clocking and signal processing signals customized for each application. A fiber optic link passes image data and commands to VME or PCI interface boards resident in a host computer to the controller. CCD signal processing is done with a dual slope integrator operating at speeds of up to one Megapixel per second per channel. Signal processing of IR arrays is done either with a dual channel video processor or a four channel video processor that has built-in image memory and a coadder to 32-bit precision for operating high background arrays. Recent developments underway include the implementation of a fast fiber optic data link operating at a speed of 12.5 Megapixels per second for fast image transfer from the controller to the host computer, and supporting image acquisition software and device drivers for the PCI interface board for the Sun Solaris, Linux and Windows 2000 operating systems.

  9. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    KAUST Repository

    Bruno, Mark

    2016-09-29

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9\\'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals.

  10. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    KAUST Repository

    Bruno, Mark; Koschmieder, Julian; Wuest, Florian; Schaub, Patrick; Fehling-Kaschek, Mirjam; Timmer, Jens; Beyer, Peter; Al-Babili, Salim

    2016-01-01

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals.

  11. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    Science.gov (United States)

    Bruno, Mark; Koschmieder, Julian; Wuest, Florian; Schaub, Patrick; Fehling-Kaschek, Mirjam; Timmer, Jens; Beyer, Peter; Al-Babili, Salim

    2016-01-01

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals. PMID:27811075

  12. Using Information on Exposure to Characterizing Risks to Human Health from Concurrent Exposures to Multiple Chemicals

    NARCIS (Netherlands)

    Mr Price, PSP

    2012-01-01

    This thesis explores the concept of using exposure information to understand, organize, and manage the risks associated with cumulative exposures to chemicals (exposures to multiple chemicals from multiple sources). The issue of cumulative exposures was identified in more than 30 years ago, but in

  13. Charge diffusion in CCD X-ray detectors

    International Nuclear Information System (INIS)

    Pavlov, George G.; Nousek, John A.

    1999-01-01

    Critical to the detection of X-rays by CCDs, is the detailed process of charge diffusion and drift within the device. We reexamine the prescriptions currently used in the modeling of X-ray CCD detectors to provide analytic expressions for the charge distribution over the CCD pixels which are suitable for use in numerical simulations of CCD response. Our treatment results in models which predict charge distributions which are more centrally peaked and have flatter wings than the Gaussian shapes predicted by previous work and adopted in current CCD modeling codes

  14. Fully depleted back-illuminated p-channel CCD development

    Energy Technology Data Exchange (ETDEWEB)

    Bebek, Chris J.; Bercovitz, John H.; Groom, Donald E.; Holland, Stephen E.; Kadel, Richard W.; Karcher, Armin; Kolbe, William F.; Oluseyi, Hakeem M.; Palaio, Nicholas P.; Prasad, Val; Turko, Bojan T.; Wang, Guobin

    2003-07-08

    An overview of CCD development efforts at Lawrence Berkeley National Laboratory is presented. Operation of fully-depleted, back-illuminated CCD's fabricated on high resistivity silicon is described, along with results on the use of such CCD's at ground-based observatories. Radiation damage and point-spread function measurements are described, as well as discussion of CCD fabrication technologies.

  15. CCD's at TPC

    International Nuclear Information System (INIS)

    Zeller, M.E.

    1977-01-01

    The CCD, Charge Coupled Device, is an analog shift register for which application to the readout of particle detectors has recently been realized. These devices can be used to detect optical information directly, providing an automated readout for streamer or other optical chambers, or as a single input shift register, acting in this instance as a delay line for analog information. A description is given of the latter mode of operation and its utility as a readout method for drift chambers. Most of the information contained herein has been obtained from tests performed in connection with PEP TPC project, PEP-4. That detector will employ approximately 10 4 CCD's making it a reasonable testing ground for ISABELLE size detectors

  16. Purification and crystallization of Vibrio fischeri CcdB and its complexes with fragments of gyrase and CcdA

    International Nuclear Information System (INIS)

    De Jonge, Natalie; Buts, Lieven; Vangelooven, Joris; Mine, Natacha; Van Melderen, Laurence; Wyns, Lode; Loris, Remy

    2007-01-01

    A CcdB homologue from V. fischeri was overexpressed in E. coli and purified. The free protein was crystallized, as were its complexes with fragments of E. coli and V. fischeri gyrase and with the F-plasmid CcdA C-terminal domain. The ccd toxin–antitoxin module from the Escherichia coli F plasmid has a homologue on the Vibrio fischeri integron. The homologue of the toxin (CcdB Vfi ) was crystallized in two different crystal forms. The first form belongs to space group I23 or I2 1 3, with unit-cell parameter a = 84.5 Å, and diffracts to 1.5 Å resolution. The second crystal form belongs to space group C2, with unit-cell parameters a = 58.5, b = 43.6, c = 37.5 Å, β = 110.0°, and diffracts to 1.7 Å resolution. The complex of CcdB Vfi with the GyrA14 Vfi fragment of V. fischeri gyrase crystallizes in space group P2 1 2 1 2 1 , with unit-cell parameters a = 53.5, b = 94.6, c = 58.1 Å, and diffracts to 2.2 Å resolution. The corresponding mixed complex with E. coli GyrA14 Ec crystallizes in space group C2, with unit-cell parameters a = 130.1, b = 90.8, c = 58.1 Å, β = 102.6°, and diffracts to 1.95 Å. Finally, a complex between CcdB Vfi and part of the F-plasmid antitoxin CcdA F crystallizes in space group P2 1 2 1 2 1 , with unit-cell parameters a = 46.9, b = 62.6, c = 82.0 Å, and diffracts to 1.9 Å resolution

  17. Follow-up study of children with cerebral coordination disturbance (CCD, Vojta).

    Science.gov (United States)

    Imamura, S; Sakuma, K; Takahashi, T

    1983-01-01

    713 children (from newborn to 12-month-old) with delayed motor development were carefully examined and classified into normal, very light cerebral coordination disturbance (CCD, Vojta), light CCD, moderate CCD, severe CCD, suspected cerebral palsy (CP) and other diseases at their first visit, and were followed up carefully. Finally, 89.0% of very light CCD, 71.4% of light CCD, 56.0% of moderate CCD and 30.0% of severe CCD developed into normal. 59.5% of moderate CCD and 45.5% of severe CCD among children who were given Vojta's physiotherapy developed into normal. The classification of cases with delayed motor development into very light, light, moderate and severe CCD based on the extent of abnormality in their postural reflexes is useful and well correlated with their prognosis. Treatment by Vojta's method seems to be efficient and helpful for young children with delayed motor development.

  18. Versatile ultrafast pump-probe imaging with high sensitivity CCD camera

    OpenAIRE

    Pezeril , Thomas; Klieber , Christoph; Temnov , Vasily; Huntzinger , Jean-Roch; Anane , Abdelmadjid

    2012-01-01

    International audience; A powerful imaging technique based on femtosecond time-resolved measurements with a high dynamic range, commercial CCD camera is presented. Ultrafast phenomena induced by a femtosecond laser pump are visualized through the lock-in type acquisition of images recorded by a femtosecond laser probe. This technique allows time-resolved measurements of laser excited phenomena at multiple probe wavelengths (spectrometer mode) or conventional imaging of the sample surface (ima...

  19. Purification and crystallization of Vibrio fischeri CcdB and its complexes with fragments of gyrase and CcdA

    Energy Technology Data Exchange (ETDEWEB)

    De Jonge, Natalie, E-mail: ndejonge@vub.ac.be; Buts, Lieven; Vangelooven, Joris [Department of Molecular and Cellular Interactions, VIB, Pleinlaan 2, 1050 Brussels (Belgium); Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels (Belgium); Mine, Natacha; Van Melderen, Laurence [Laboratoire de Génétique des Procaryotes, Institut de Biologie et de Médecine, Université Libre de Bruxelles, Gosselies (Belgium); Wyns, Lode; Loris, Remy [Department of Molecular and Cellular Interactions, VIB, Pleinlaan 2, 1050 Brussels (Belgium); Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels (Belgium)

    2007-04-01

    A CcdB homologue from V. fischeri was overexpressed in E. coli and purified. The free protein was crystallized, as were its complexes with fragments of E. coli and V. fischeri gyrase and with the F-plasmid CcdA C-terminal domain. The ccd toxin–antitoxin module from the Escherichia coli F plasmid has a homologue on the Vibrio fischeri integron. The homologue of the toxin (CcdB{sub Vfi}) was crystallized in two different crystal forms. The first form belongs to space group I23 or I2{sub 1}3, with unit-cell parameter a = 84.5 Å, and diffracts to 1.5 Å resolution. The second crystal form belongs to space group C2, with unit-cell parameters a = 58.5, b = 43.6, c = 37.5 Å, β = 110.0°, and diffracts to 1.7 Å resolution. The complex of CcdB{sub Vfi} with the GyrA14{sub Vfi} fragment of V. fischeri gyrase crystallizes in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 53.5, b = 94.6, c = 58.1 Å, and diffracts to 2.2 Å resolution. The corresponding mixed complex with E. coli GyrA14{sub Ec} crystallizes in space group C2, with unit-cell parameters a = 130.1, b = 90.8, c = 58.1 Å, β = 102.6°, and diffracts to 1.95 Å. Finally, a complex between CcdB{sub Vfi} and part of the F-plasmid antitoxin CcdA{sub F} crystallizes in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 46.9, b = 62.6, c = 82.0 Å, and diffracts to 1.9 Å resolution.

  20. MiCPhot: A prime-focus multicolor CCD photometer on the 85-cm Telescope

    International Nuclear Information System (INIS)

    Zhou Aiying; Jiang Xiaojun; Wei Jianyan; Zhang Yanping

    2009-01-01

    We describe a new BV RI multicolor CCD photometric system situated at the prime focus of the 85-cm telescope at the Xinglong Station of NAOC. Atmospheric extinction effects, photometric accuracy and color calibration dependence of the system are investigated. Additional attention was paid to giving observers guidance in estimating throughput, detection limit, signal-to-noise ratio and exposure time. (invited reviews)

  1. Noise characteristics of neutron images obtained by cooled CCD device

    International Nuclear Information System (INIS)

    Taniguchi, Ryoichi; Sasaki, Ryoya; Okuda, Shuichi; Okamoto, Ken-Ichi; Ogawa, Yoshihiro; Tsujimoto, Tadashi

    2009-01-01

    The noise characteristics of a cooled CCD device induced by neutron and gamma ray irradiation have been investigated. In the cooled CCD images, characteristic white spot noises (CCD noise) frequently appeared, which have a shape like a pixel in most cases and their brightness is extremely high compared with that of the image pattern. They could be divided into the two groups, fixed pattern noise (FPN) and random noise. The former always appeared in the same position in the image and the latter appeared at any position. In the background image, nearly all of the CCD noises were found to be the FPN, while many of them were the random noise during the irradiation. The random CCD noises increased with irradiation and decreased soon after the irradiation. In the case of large irradiation, a part of the CCD noise remained as the FPN. These facts suggest that the CCD noise is a phenomenon strongly relating to radiation damage of the CCD device.

  2. The development of large-aperture test system of infrared camera and visible CCD camera

    Science.gov (United States)

    Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying

    2015-10-01

    Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.

  3. Multiple context mere exposure: Examining the limits of liking.

    Science.gov (United States)

    de Zilva, Daniel; Newell, Ben R; Mitchell, Chris J

    2016-01-01

    Recent evidence suggests that increased liking of exposed stimuli-a phenomenon known as the mere exposure effect-is dependent on experiencing the stimuli in the same context at exposure and test. Three experiments extended this work by examining the effect of presenting target stimuli in single and multiple exposure contexts. Target face stimuli were repeatedly paired with nonsense words, which took the role of contexts, across exposure. On test, the mere exposure effect was found only when the target face stimuli were presented with nonsense word cues (contexts) with which they had been repeatedly paired. The mere exposure effect was eliminated when exposure to target face stimuli with the nonsense word cues (contexts) was minimal, despite the overall number of exposures to the target face being equated across single- and multiple-context exposure conditions. The results suggest that familiarity of the relationship between stimuli and their context, not simply familiarity of the stimuli themselves, leads to liking. The finding supports a broader framework, which suggests that liking is partly a function of the consistency between past and present experiences with a target stimulus.

  4. CCD Astrophotography High-Quality Imaging from the Suburbs

    CERN Document Server

    Stuart, Adam

    2006-01-01

    This is a reference book for amateur astronomers who have become interested in CCD imaging. Those glorious astronomical images found in astronomy magazines might seem out of reach to newcomers to CCD imaging, but this is not the case. Great pictures are attainable with modest equipment. Adam Stuart’s many beautiful images, reproduced in this book, attest to the quality of – initially – a beginner’s efforts. Chilled-chip astronomical CCD-cameras and software are also wonderful tools for cutting through seemingly impenetrable light-pollution. CCD Astrophotography from the Suburbs describes one man’s successful approach to the problem of getting high-quality astronomical images under some of the most light-polluted conditions. Here is a complete and thoroughly tested program that will help every CCD-beginner to work towards digital imaging of the highest quality. It is equally useful to astronomers who have perfect observing conditions, as to those who have to observe from light-polluted city skies.

  5. BECN2 interacts with ATG14 through a metastable coiled-coil to mediate autophagy: BECN2 CCD Structure and Interaction with ATG14

    Energy Technology Data Exchange (ETDEWEB)

    Su, Minfei; Li, Yue; Wyborny, Shane; Neau, David; Chakravarthy, Srinivas; Levine, Beth; Colbert, Christopher L.; Sinha, Sangita C. (NDSU); (IIT); (Cornell); (UTSMC)

    2017-03-12

    ATG14 binding to BECN/Beclin homologs is essential for autophagy, a critical catabolic homeostasis pathway. Here, we show that the α-helical, coiled-coil domain (CCD) of BECN2, a recently identified mammalian BECN1 paralog, forms an antiparallel, curved homodimer with seven pairs of nonideal packing interactions, while the BECN2 CCD and ATG14 CCD form a parallel, curved heterodimer stabilized by multiple, conserved polar interactions. Compared to BECN1, the BECN2 CCD forms a weaker homodimer, but binds more tightly to the ATG14 CCD. Mutation of nonideal BECN2 interface residues to more ideal pairs improves homodimer self-association and thermal stability. Unlike BECN1, all BECN2 CCD mutants bind ATG14, although more weakly than wild type. Thus, polar BECN2 CCD interface residues result in a metastable homodimer, facilitating dissociation, but enable better interactions with polar ATG14 residues stabilizing the BECN2:ATG14 heterodimer. These structure-based mechanistic differences in BECN1 and BECN2 homodimerization and heterodimerization likely dictate competitive ATG14 recruitment.

  6. Custom CCD for adaptive optics applications

    Science.gov (United States)

    Downing, Mark; Arsenault, Robin; Baade, Dietrich; Balard, Philippe; Bell, Ray; Burt, David; Denney, Sandy; Feautrier, Philippe; Fusco, Thierry; Gach, Jean-Luc; Diaz Garcia, José Javier; Guillaume, Christian; Hubin, Norbert; Jorden, Paul; Kasper, Markus; Meyer, Manfred; Pool, Peter; Reyes, Javier; Skegg, Michael; Stadler, Eric; Suske, Wolfgang; Wheeler, Patrick

    2006-06-01

    ESO and JRA2 OPTICON have funded e2v technologies to develop a compact packaged Peltier cooled 24 μm square 240x240 pixels split frame transfer 8-output back-illuminated L3Vision CCD3, L3Vision CCD for Adaptive Optic Wave Front Sensor (AO WFS) applications. The device is designed to achieve sub-electron read noise at frame rates from 25 Hz to 1,500 Hz and dark current lower than 0.01 e-/pixel/frame. The development has many unique features. To obtain high frame rates, multi-output EMCCD gain registers and metal buttressing of row clock lines are used. The baseline device is built in standard silicon. In addition, a split wafer run has enabled two speculative variants to be built; deep depletion silicon devices to improve red response and devices with an electronic shutter to extend use to Rayleigh and Pulsed Laser Guide Star applications. These are all firsts for L3Vision CCDs. The designs of the CCD and Peltier package have passed their reviews and fabrication has begun. This paper will describe the progress to date, the requirements and the design of the CCD and compact Peltier package, technology trade-offs, schedule and proposed test plan. High readout speed, low noise and compactness (requirement to fit in confined spaces) provide special challenges to ESO's AO variant of its NGC, New General detector Controller to drive this CCD. This paper will describe progress made on the design of the controller to meet these special needs.

  7. Rethinking CCD's Significance in Estimating Late Neogene Whole Ocean Carbonate Budget

    Science.gov (United States)

    Si, W.; Rosenthal, Y.

    2017-12-01

    The global averaged calcite compensation depth (CCD) record is conventionally used to reconstruct two correlatable parameters of the carbonate system - the alkalinity budget of the ocean and/or the saturation state of the ocean. Accordingly, the available CCD reconstructions have been interpreted to suggest either relative stable (Pearson and Palmer, 2000) or increased alkalinity of the ocean over the past 15 Ma (Tyrrell and Zeebe, 2004; Pälike et al., 2012). However, CCD alone is insufficient to constrain the carbonate system because the weathering flux of alkalinity into the ocean is not only balanced by CaCO3 dissolution on the seafloor but also by the biologic production in the euphotic zone and, the CCD records cannot be readily interpreted as changes in either process. Here, we present evidence of the co-evolution of surface CaCO3 production and deepsea dissolution through the late Neogene. By examining separately the mass accumulation rates (MAR) of coccoliths, planktonic foraminifera, and quantifying dissolution (using a proxy revised from Broecker et al., 1999) in seventeen deepsea cores from multiple depth-transects, we find that 1) MAR of dissolution-resistant coccoliths was substantially higher in the mid Miocene and declining on a global scale towards the present; 2) unlike coccoliths, MAR of planktonic foraminifera, shows no apparent secular trend through that time; 3) the revised dissolution index, shows significantly improved preservation of planktonic foraminiferal shells over that time, particularly at intermediate water depth and exhibits close association between changes in preservation with key climatic events. Our new records have two immediate implications. First, the substantially weakened pelagic biogenic carbonate production from mid Miocene to present alone could account for the improved preservation of deepsea carbonates without calling for a scenario of increased weathering input. Second, with the constrain of global averaged CCD

  8. THE ACCURACY OF Hβ CCD PHOTOMETRY

    Directory of Open Access Journals (Sweden)

    C. Kim

    1994-12-01

    Full Text Available We have undertaken CCD observations of field standard stars with Hβ photometric system to investigate the reliability of Hβ CCD photometry. Flat fielding with dome flat and sky flat for Hβw and Hβn filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our Hβ values observed with 2.3m reflector and standard values. However, Hβ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of Hβ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson (1981.

  9. Correlation and image compression for limited-bandwidth CCD.

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Douglas G.

    2005-07-01

    As radars move to Unmanned Aerial Vehicles with limited-bandwidth data downlinks, the amount of data stored and transmitted with each image becomes more significant. This document gives the results of a study to determine the effect of lossy compression in the image magnitude and phase on Coherent Change Detection (CCD). We examine 44 lossy compression types, plus lossless zlib compression, and test each compression method with over 600 CCD image pairs. We also derive theoretical predictions for the correlation for most of these compression schemes, which compare favorably with the experimental results. We recommend image transmission formats for limited-bandwidth programs having various requirements for CCD, including programs which cannot allow performance degradation and those which have stricter bandwidth requirements at the expense of CCD performance.

  10. Typical effects of laser dazzling CCD camera

    Science.gov (United States)

    Zhang, Zhen; Zhang, Jianmin; Shao, Bibo; Cheng, Deyan; Ye, Xisheng; Feng, Guobin

    2015-05-01

    In this article, an overview of laser dazzling effect to buried channel CCD camera is given. The CCDs are sorted into staring and scanning types. The former includes the frame transfer and interline transfer types. The latter includes linear and time delay integration types. All CCDs must perform four primary tasks in generating an image, which are called charge generation, charge collection, charge transfer and charge measurement. In camera, the lenses are needed to input the optical signal to the CCD sensors, in which the techniques for erasing stray light are used. And the electron circuits are needed to process the output signal of CCD, in which many electronic techniques are used. The dazzling effects are the conjunct result of light distribution distortion and charge distribution distortion, which respectively derive from the lens and the sensor. Strictly speaking, in lens, the light distribution is not distorted. In general, the lens are so well designed and fabricated that its stray light can be neglected. But the laser is of much enough intensity to make its stray light obvious. In CCD image sensors, laser can induce a so large electrons generation. Charges transfer inefficiency and charges blooming will cause the distortion of the charge distribution. Commonly, the largest signal outputted from CCD sensor is restricted by capability of the collection well of CCD, and can't go beyond the dynamic range for the subsequent electron circuits maintaining normal work. So the signal is not distorted in the post-processing circuits. But some techniques in the circuit can make some dazzling effects present different phenomenon in final image.

  11. High-Voltage Clock Driver for Photon-Counting CCD Characterization

    Science.gov (United States)

    Baker, Robert

    2013-01-01

    A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

  12. Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.

    Science.gov (United States)

    Iglesias, Francisco A; Feller, Alex; Nagaraju, Krishnappa

    2015-07-01

    Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.

  13. The use of a CCD imaging system for X-ray film intensity measurement

    International Nuclear Information System (INIS)

    Grigg, M.W.; Barnea, Z.

    1994-01-01

    The use of a simple CCD-based imaging system for digitizing and x-ray film image is demonstrated. A method of extending the region of linear response of the film based upon an analytic representation of the observed response to a series of increasing exposures is described. The validity of the procedure is illustrated through an example of the absolute intensity measurement of a reflection of cadmium sulphide. 3 refs., 7 figs

  14. 15 CFR 740.19 - Consumer Communications Devices (CCD).

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Consumer Communications Devices (CCD... EXCEPTIONS § 740.19 Consumer Communications Devices (CCD). (a) Authorization. This License Exception... controllers designed for chemical processing) designated EAR99; (4) Graphics accelerators and graphics...

  15. Active Pixel Sensors: Are CCD's Dinosaurs?

    Science.gov (United States)

    Fossum, Eric R.

    1993-01-01

    Charge-coupled devices (CCD's) are presently the technology of choice for most imaging applications. In the 23 years since their invention in 1970, they have evolved to a sophisticated level of performance. However, as with all technologies, we can be certain that they will be supplanted someday. In this paper, the Active Pixel Sensor (APS) technology is explored as a possible successor to the CCD. An active pixel is defined as a detector array technology that has at least one active transistor within the pixel unit cell. The APS eliminates the need for nearly perfect charge transfer -- the Achilles' heel of CCDs. This perfect charge transfer makes CCD's radiation 'soft,' difficult to use under low light conditions, difficult to manufacture in large array sizes, difficult to integrate with on-chip electronics, difficult to use at low temperatures, difficult to use at high frame rates, and difficult to manufacture in non-silicon materials that extend wavelength response.

  16. The design and development of low- and high-voltage ASICs for space-borne CCD cameras

    Science.gov (United States)

    Waltham, N.; Morrissey, Q.; Clapp, M.; Bell, S.; Jones, L.; Torbet, M.

    2017-12-01

    The CCD remains the pre-eminent visible and UV wavelength image sensor in space science, Earth and planetary remote sensing. However, the design of space-qualified CCD readout electronics is a significant challenge with requirements for low-volume, low-mass, low-power, high-reliability and tolerance to space radiation. Space-qualified components are frequently unavailable and up-screened commercial components seldom meet project or international space agency requirements. In this paper, we describe an alternative approach of designing and space-qualifying a series of low- and high-voltage mixed-signal application-specific integrated circuits (ASICs), the ongoing development of two low-voltage ASICs with successful flight heritage, and two new high-voltage designs. A challenging sub-system of any CCD camera is the video processing and digitisation electronics. We describe recent developments to improve performance and tolerance to radiation-induced single event latchup of a CCD video processing ASIC originally developed for NASA's Solar Terrestrial Relations Observatory and Solar Dynamics Observatory. We also describe a programme to develop two high-voltage ASICs to address the challenges presented with generating a CCD's bias voltages and drive clocks. A 0.35 μm, 50 V tolerant, CMOS process has been used to combine standard low-voltage 3.3 V transistors with high-voltage 50 V diffused MOSFET transistors that enable output buffers to drive CCD bias drains, gates and clock electrodes directly. We describe a CCD bias voltage generator ASIC that provides 24 independent and programmable 0-32 V outputs. Each channel incorporates a 10-bit digital-to-analogue converter, provides current drive of up to 20 mA into loads of 10 μF, and includes current-limiting and short-circuit protection. An on-chip telemetry system with a 12-bit analogue-to-digital converter enables the outputs and multiple off-chip camera voltages to be monitored. The ASIC can drive one or more CCDs and

  17. Exposure to Multiple Languages Enhances Communication Skills in Infancy

    Science.gov (United States)

    Liberman, Zoe; Woodward, Amanda L.; Keysar, Boaz; Kinzler, Katherine D.

    2017-01-01

    Early exposure to multiple languages can enhance children's communication skills, even when children are effectively monolingual (Fan, Liberman, Keysar & Kinzler, 2015). Here we report evidence that the social benefits of multilingual exposure emerge in infancy. Sixteen-month-old infants participated in a communication task that required…

  18. Solution structure and elevator mechanism of the membrane electron transporter CcdA.

    Science.gov (United States)

    Zhou, Yunpeng; Bushweller, John H

    2018-02-01

    Membrane oxidoreductase CcdA plays a central role in supplying reducing equivalents from the bacterial cytoplasm to the envelope. It transports electrons across the membrane using a single pair of cysteines by a mechanism that has not yet been elucidated. Here we report an NMR structure of the Thermus thermophilus CcdA (TtCcdA) in an oxidized and outward-facing state. CcdA consists of two inverted structural repeats of three transmembrane helices (2 × 3-TM). We computationally modeled and experimentally validated an inward-facing state, which suggests that CcdA uses an elevator-type movement to shuttle the reactive cysteines across the membrane. CcdA belongs to the LysE superfamily, and thus its structure may be relevant to other LysE clan transporters. Structure comparisons of CcdA, semiSWEET, Pnu, and major facilitator superfamily (MFS) transporters provide insights into membrane transporter architecture and mechanism.

  19. CCD camera eases the control of a soda recovery boiler; CCD-kamera helpottaa soodakattilan valvontaa

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, L.

    2001-07-01

    Fortum Technology has developed a CCD firebox camera, based on semiconductor technology, enduring hard conditions of soda recovery boiler longer than traditional cameras. The firebox camera air- cooled and the same air is pressed over the main lens so it remains clean despite of the alkaline liquor splashing around in the boiler. The image of the boiler is transferred through the main lens, image transfer lens and a special filter, mounted inside the camera tube, into the CCD camera. The first CCD camera system has been in use since 1999 in Sunila pulp mill in Kotka, owned by Myllykoski Oy and Enso Oyj. The mill has two medium-sized soda recovery boilers. The amount of black liquor, formed daily, is about 2000 tons DS, which is more than enough for the heat generation. Even electric power generation exceeds sometimes the demand, so the surplus power can be sold out. Black liquor is sprayed inside the soda recovery boiler with high pressure. The liquor form droplets in the boiler, the temperature of which is over 1000 deg C. A full-hot pile is formed at the bottom of the boiler after burning. The size and shape of the pile effect on the efficiency and the emissions of the boiler. The camera has operated well.

  20. Radiation damage of the PCO Pixelfly VGA CCD camera of the BES system on KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Náfrádi, Gábor, E-mail: nafradi@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Kovácsik, Ákos, E-mail: kovacsik.akos@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Pór, Gábor, E-mail: por@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Lampert, Máté, E-mail: lampert.mate@wigner.mta.hu [Wigner RCP, RMI, EURATOM Association, POB 49, 1525 Budapest (Hungary); Un Nam, Yong, E-mail: yunam@nfri.re.kr [NFRI, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon 305-806 (Korea, Republic of); Zoletnik, Sándor, E-mail: zoletnik.sandor@wigner.mta.hu [Wigner RCP, RMI, EURATOM Association, POB 49, 1525 Budapest (Hungary)

    2015-01-11

    A PCO Pixelfly VGA CCD camera which is part a of the Beam Emission Spectroscopy (BES) diagnostic system of the Korea Superconducting Tokamak Advanced Research (KSTAR) used for spatial calibrations, suffered from serious radiation damage, white pixel defects have been generated in it. The main goal of this work was to identify the origin of the radiation damage and to give solutions to avoid it. Monte Carlo N-Particle eXtended (MCNPX) model was built using Monte Carlo Modeling Interface Program (MCAM) and calculations were carried out to predict the neutron and gamma-ray fields in the camera position. Besides the MCNPX calculations pure gamma-ray irradiations of the CCD camera were carried out in the Training Reactor of BME. Before, during and after the irradiations numerous frames were taken with the camera with 5 s long exposure times. The evaluation of these frames showed that with the applied high gamma-ray dose (1.7 Gy) and dose rate levels (up to 2 Gy/h) the number of the white pixels did not increase. We have found that the origin of the white pixel generation was the neutron-induced thermal hopping of the electrons which means that in the future only neutron shielding is necessary around the CCD camera. Another solution could be to replace the CCD camera with a more radiation tolerant one for example with a suitable CMOS camera or apply both solutions simultaneously.

  1. CCD camera system for use with a streamer chamber

    International Nuclear Information System (INIS)

    Angius, S.A.; Au, R.; Crawley, G.C.; Djalali, C.; Fox, R.; Maier, M.; Ogilvie, C.A.; Molen, A. van der; Westfall, G.D.; Tickle, R.S.

    1988-01-01

    A system based on three charge-coupled-device (CCD) cameras is described here. It has been used to acquire images from a streamer chamber and consists of three identical subsystems, one for each camera. Each subsystem contains an optical lens, CCD camera head, camera controller, an interface between the CCD and a microprocessor, and a link to a minicomputer for data recording and on-line analysis. Image analysis techniques have been developed to enhance the quality of the particle tracks. Some steps have been made to automatically identify tracks and reconstruct the event. (orig.)

  2. Novel driver method to improve ordinary CCD frame rate for high-speed imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Tong-Ding, E-mail: snuohui@126.com; Li, Bin-Kang; Yang, Shao-Hua; Guo, Ming-An; Yan, Ming

    2016-06-21

    The use of ordinary Charge-coupled-Device (CCD) imagers for the analysis of fast physical phenomenon is restricted because of the low-speed performance resulting from their long output times. Even though the form of Intensified-CCD (ICCD), coupled with a gated image intensifier, has extended their use for high speed imaging, the deficiency remains to be solved that ICDD could record only one image in a single shot. This paper presents a novel driver method designed to significantly improve the ordinary interline CCD burst frame rate for high-speed photography. This method is based on the use of vertical registers as storage, so that a small number of additional frames comprised of reduced-spatial-resolution images obtained via a specific sampling operation can be buffered. Hence, the interval time of the received series of images is related to the exposure and vertical transfer times only and, thus, the burst frame rate can be increased significantly. A prototype camera based on this method is designed as part of this study, exhibiting a burst rate of up to 250,000 frames per second (fps) and a capacity to record three continuous images. This device exhibits a speed enhancement of approximately 16,000 times compared with the conventional speed, with a spatial resolution reduction of only 1/4.

  3. CCD-based X-ray detectors for X-ray diffraction studies

    International Nuclear Information System (INIS)

    Ito, K.; Amemiya, Y.

    1999-01-01

    CCD-based X-ray detectors are getting to be used for X-ray diffraction studies especially in the studies where real time (automated) measurements and time-resolved measurements are required. Principles and designs of two typical types of CCD-based detectors are described; one is ths system in which x-ray image intensifiers are coupled to maximize the detective quantum efficiency for time-resolved measurements, and the other is the system in which tapered optical fibers are coupled for the reduction of the image into the CCD, which is optimized for automated measurements for protein crystallography. These CCD-based X-ray detectors have an image distortion and non-uniformity of response to be corrected by software. Correction schemes which we have developed are also described. (author)

  4. Agricultural Exposures, Multiple Myeloma Etiology: Profile of Jonathan Hofmann

    Science.gov (United States)

    Tenure-track investigator Jonathan Hofmann, Ph.D., M.P.H., has established a research program in the Occupational and Environmental Epidemiology Branch focused on the role of agricultural exposures in the etiology of multiple myeloma and other cancers, and on understanding the biological mechanisms that influence the development and progression of multiple myeloma.

  5. Programmable CCD imaging system for synchrotron radiation studies

    International Nuclear Information System (INIS)

    Rodricks, B.; Brizard, C.

    1992-01-01

    A real-time imaging system for x-ray detection has been developed. The CAMAC-based system has a Charge Coupled Device (CCD) as its active detection element. The electronics consist of a CAMAC-crate-based dedicated microprocessor coupled to arbitrary waveform generators, programmable timing, and ADC modules. The hardware flexibility achievable through this system enables one to use virtually any commercially available CCD. A dedicated CAMAC-based display driver allows for real-time imaging on a high-resolution color monitor. An optional front end consisting of a fiber-optic taper and a focusing optical lens system coupled to a phosphor screen allows for large area imaging. Further, programming flexibility, in which the detector can be used in different read-out modes, enables it to be exploited for time-resolved experiments. In one mode, sections of the CCD can be read-out with millisecond time-resolution and, in another, the use of the CCD as a storage device is exploited resulting in microsecond time-resolution. Three different CCDs with radically different read-out timings and waveforms have been tested: the TI 4849, a 39Ox584 pixel array; TC 215, a 1024x1O24 pixel array; and the TH 7883, a 576x384 pixel array. The TC 215 and TI 4849 are single-phase CCDs manufactured by Texas Instruments, and the TH 7883 is a four-phase device manufactured by Thomson-CSF. The CCD characterized for uniformity, charge transfer efficiency (CTE), linearity, and sensitivity is the TC215

  6. An efficient multiple exposure image fusion in JPEG domain

    Science.gov (United States)

    Hebbalaguppe, Ramya; Kakarala, Ramakrishna

    2012-01-01

    In this paper, we describe a method to fuse multiple images taken with varying exposure times in the JPEG domain. The proposed algorithm finds its application in HDR image acquisition and image stabilization for hand-held devices like mobile phones, music players with cameras, digital cameras etc. Image acquisition at low light typically results in blurry and noisy images for hand-held camera's. Altering camera settings like ISO sensitivity, exposure times and aperture for low light image capture results in noise amplification, motion blur and reduction of depth-of-field respectively. The purpose of fusing multiple exposures is to combine the sharp details of the shorter exposure images with high signal-to-noise-ratio (SNR) of the longer exposure images. The algorithm requires only a single pass over all images, making it efficient. It comprises of - sigmoidal boosting of shorter exposed images, image fusion, artifact removal and saturation detection. Algorithm does not need more memory than a single JPEG macro block to be kept in memory making it feasible to be implemented as the part of a digital cameras hardware image processing engine. The Artifact removal step reuses the JPEGs built-in frequency analysis and hence benefits from the considerable optimization and design experience that is available for JPEG.

  7. Characterization of a pnCCD for applications with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Send, S., E-mail: send@physik.uni-siegen.de [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Abboud, A. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Hartmann, R.; Huth, M. [PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Leitenberger, W. [University of Potsdam, Department of Physics, Karl-Liebknecht-Straße 24/25, 14476 Potsdam (Germany); Pashniak, N. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Schmidt, J. [PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Strüder, L. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Max-Planck-Institut für extraterrestrische Physik, Giessenbachstraße, 85748 Garching (Germany); Pietsch, U. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany)

    2013-05-21

    In this work we study the response of a pnCCD by means of X-ray spectroscopy in the energy range between 6 keV and 20 keV and by Laue diffraction techniques. The analyses include measurements of characteristic detector parameters like energy resolution, count rate capability and effects of different gain settings. The limit of a single photon counting operation in white beam X-ray diffraction experiments is discussed with regard to the occurrence of pile-up events, for which the energy information about individual photons is lost. In case of monochromatic illumination the pnCCD can be used as a fast conventional CCD with a charge handling capacity (CHC) of about 300,000 electrons per pixel. If the CHC is exceeded, any surplus charge will spill to neighboring pixels perpendicular to the transfer direction due to electrostatic repulsion. The possibilities of increasing the number of storable electrons are investigated for different voltage settings by exposing a single pixel with X-rays generated by a microfocus X-ray source. The pixel binning mode is tested as an alternative approach that enables a pnCCD operation with significantly shorter readout times. -- Highlights: ► The pnCCD acts as a four-dimensional detector for white X-rays. ► Its performance for applications with synchrotron radiation is investigated. ► The pnCCD can be used for single photon counting and photon integration. ► The operation mode depends on the local frequencies of pile-up events. ► The pnCCD can be optimized for X-ray spectroscopy and X-ray imaging.

  8. Software design of control system of CCD side-scatter lidar

    Science.gov (United States)

    Kuang, Zhiqiang; Liu, Dong; Deng, Qian; Zhang, Zhanye; Wang, Zhenzhu; Yu, Siqi; Tao, Zongming; Xie, Chenbo; Wang, Yingjian

    2018-03-01

    Because of the existence of blind zone and transition zone, the application of backscattering lidar in near-ground is limited. The side-scatter lidar equipped with the Charge Coupled Devices (CCD) can separate the transmitting and receiving devices to avoid the impact of the geometric factors which is exited in the backscattering lidar and, detect the more precise near-ground aerosol signals continuously. Theories of CCD side-scatter lidar and the design of control system are introduced. The visible control of laser and CCD and automatic data processing method of the side-scatter lidar are developed by using the software of Visual C #. The results which are compared with the calibration of the atmospheric aerosol lidar data show that signals from the CCD side- scatter lidar are convincible.

  9. A new approach to modelling radiation noise in CCD's

    International Nuclear Information System (INIS)

    Chugg, A.; Hopkinson, G.

    1998-01-01

    The energy depositions reported by Monte Carlo electron-photon irradiation transport codes are subject to a random error due to the finite number of particle histories used to generate the results. These statistical variations, normally a nuisance, may also be identified with the real radiation noise effects experienced by CCD pixels in persistent radiation environments. This paper explores the practicability of such radiation noise modelling by applying the ACCEPT code from the ITS suite to the case of a shielded CCD exposed to an electron flux. The results are compared with those obtained in a subsequent electron irradiation of the CCD by a Van de Graaff accelerator

  10. The interaction of DNA gyrase with the bacterial toxin CcdB

    DEFF Research Database (Denmark)

    Kampranis, S C; Howells, A J; Maxwell, A

    1999-01-01

    CcdB is a bacterial toxin that targets DNA gyrase. Analysis of the interaction of CcdB with gyrase reveals two distinct complexes. An initial complex (alpha) is formed by direct interaction between GyrA and CcdB; this complex can be detected by affinity column and gel-shift analysis, and has...... of this initial complex with ATP in the presence of GyrB and DNA slowly converts it to a second complex (beta), which has a lower rate of ATP hydrolysis and is unable to catalyse supercoiling. The efficiency of formation of this inactive complex is dependent on the concentrations of ATP and CcdB. We suggest...

  11. Discriminação de variedades de citros em imagens CCD/CBERS-2 Discrimination of citrus varieties using CCD/CBERS-2 satellite imagery

    Directory of Open Access Journals (Sweden)

    Ieda Del'Arco Sanches

    2008-02-01

    Full Text Available O presente trabalho teve o objetivo de avaliar as imagens CCD/CBERS-2 quanto à possibilidade de discriminarem variedades de citros. A área de estudo localiza-se em Itirapina (SP e, para este estudo, foram utilizadas imagens CCD de três datas (30/05/2004, 16/08/2004 e 11/09/2004. Um modelo que integra os elementos componentes da cena citrícola sensoriada é proposto com o objetivo de explicar a variabilidade das respostas das parcelas de citros em imagens orbitais do tipo CCD/CBERS-2. Foram feitas classificações pelos algoritmos Isoseg e Maxver e, de acordo com o índice kappa, concluiu-se que é possível obterem-se exatidões qualificadas como muito boas, sendo que as melhores classificações foram conseguidas com imagens da estação seca.This paper was aimed at evaluating the possibility of discriminating citrus varieties in CCD imageries from CBERS-2 satellite ("China-Brazil Earth Resouces Satellite". The study area is located in Itirapina, São Paulo State. For this study, three CCD images from 2004 were acquired (May 30, August 16, and September 11. In order to acquire a better understanding and for explaining the variability of the spectral behavior of the citrus areas in orbital images (like as the CCD/CBERS-2 images a model that integrates the elements of the citrus scene is proposed and discussed. The images were classified by Isoseg and MaxVer classifiers. According to kappa index, it was possible to obtain classifications qualified as 'very good'. The best results were obtained with the images from the dry season.

  12. pnCCD for photon detection from near-infrared to X-rays

    International Nuclear Information System (INIS)

    Meidinger, Norbert; Andritschke, Robert; Hartmann, Robert; Herrmann, Sven; Holl, Peter; Lutz, Gerhard; Strueder, Lothar

    2006-01-01

    A pnCCD is a special type of charge-coupled device developed for spectroscopy and imaging of X-rays with high time resolution and quantum efficiency. Its most famous application is the operation on the XMM-Newton satellite, an X-ray astronomy mission that was launched by the European space agency in 1999. The excellent performance of the focal plane camera has been maintained for more than 6 years in orbit. The energy resolution in particular has shown hardly any degradation since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. This 'frame-store pnCCD' shows an enhanced performance compared to the XMM-Newton type of pnCCD. Now, more options in device design and operation are available to tailor the detector to its respective application. Part of this concept is a programmable analog signal processor, which has been developed for the readout of the CCD signals. The electronic noise of the new detector has a value of only 2 electrons equivalent noise charge (ENC), which is less than half of the figure achieved for the XMM-Newton-type pnCCD. The energy resolution for the Mn-K α line at 5.9 keV is approximately 130 eV FWHM. We have close to 100% quantum efficiency for both low- and high-energy photon detection (e.g. the C-K line at 277 eV, and the Ge-K α line at 10 keV, respectively). Very high frame rates of 1000 images/s have been achieved due to the ultra-fast readout accomplished by the parallel architecture of the pnCCD and the analog signal processor. Excellent spectroscopic performance is shown even at the relatively high operating temperature of -25 deg. C that can be achieved by a Peltier cooler. The applications of the low-noise and fast pnCCD detector are not limited to the detection of X-rays. With an anti-reflective coating deposited on the photon entrance window, we achieve high quantum efficiency also for near-infrared and optical

  13. Timing generator of scientific grade CCD camera and its implementation based on FPGA technology

    Science.gov (United States)

    Si, Guoliang; Li, Yunfei; Guo, Yongfei

    2010-10-01

    The Timing Generator's functions of Scientific Grade CCD Camera is briefly presented: it generates various kinds of impulse sequence for the TDI-CCD, video processor and imaging data output, acting as the synchronous coordinator for time in the CCD imaging unit. The IL-E2TDI-CCD sensor produced by DALSA Co.Ltd. use in the Scientific Grade CCD Camera. Driving schedules of IL-E2 TDI-CCD sensor has been examined in detail, the timing generator has been designed for Scientific Grade CCD Camera. FPGA is chosen as the hardware design platform, schedule generator is described with VHDL. The designed generator has been successfully fulfilled function simulation with EDA software and fitted into XC2VP20-FF1152 (a kind of FPGA products made by XILINX). The experiments indicate that the new method improves the integrated level of the system. The Scientific Grade CCD camera system's high reliability, stability and low power supply are achieved. At the same time, the period of design and experiment is sharply shorted.

  14. CCD characterization and measurements automation

    Czech Academy of Sciences Publication Activity Database

    Kotov, I.V.; Frank, J.; Kotov, A.I.; Kubánek, Petr; O´Connor, P.; Prouza, Michael; Radeka, V.; Takacs, P.

    2012-01-01

    Roč. 695, Dec (2012), 188-192 ISSN 0168-9002 R&D Projects: GA MŠk ME09052 Institutional research plan: CEZ:AV0Z10100502 Keywords : CCD * characterization * test automation Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.142, year: 2012

  15. Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Hardware

    Directory of Open Access Journals (Sweden)

    Y.-W. Kang

    2007-12-01

    Full Text Available We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E(768×512, KAF-1602E(1536×1024, KAF-3200E(2184×1472 made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately 0.4° C in the max. range of temperature, Δ 33° C. This CCD camera system has with readout noise 6 e^{-}, and system gain 5 e^{-}/ADU. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

  16. Study of x-ray CCD image sensor and application

    Science.gov (United States)

    Wang, Shuyun; Li, Tianze

    2008-12-01

    In this paper, we expounded the composing, specialty, parameter, its working process, key techniques and methods for charge coupled devices (CCD) twice value treatment. Disposal process for CCD video signal quantification was expatiated; X-ray image intensifier's constitutes, function of constitutes, coupling technique of X-ray image intensifier and CCD were analyzed. We analyzed two effective methods to reduce the harm to human beings when X-ray was used in the medical image. One was to reduce X-ray's radiation and adopt to intensify the image penetrated by X-ray to gain the same effect. The other was to use the image sensor to transfer the images to the safe area for observation. On this base, a new method was presented that CCD image sensor and X-ray image intensifier were combined organically. A practical medical X-ray photo electricity system was designed which can be used in the records and time of the human's penetrating images. The system was mainly made up with the medical X-ray, X-ray image intensifier, CCD vidicon with high resolution, image processor, display and so on. Its characteristics are: change the invisible X-ray into the visible light image; output the vivid images; short image recording time etc. At the same time we analyzed the main aspects which affect the system's resolution. Medical photo electricity system using X-ray image sensor can reduce the X-ray harm to human sharply when it is used in the medical diagnoses. At last we analyzed and looked forward the system's application in medical engineering and the related fields.

  17. High Dynamic Range Imaging Using Multiple Exposures

    Science.gov (United States)

    Hou, Xinglin; Luo, Haibo; Zhou, Peipei; Zhou, Wei

    2017-06-01

    It is challenging to capture a high-dynamic range (HDR) scene using a low-dynamic range (LDR) camera. This paper presents an approach for improving the dynamic range of cameras by using multiple exposure images of same scene taken under different exposure times. First, the camera response function (CRF) is recovered by solving a high-order polynomial in which only the ratios of the exposures are used. Then, the HDR radiance image is reconstructed by weighted summation of the each radiance maps. After that, a novel local tone mapping (TM) operator is proposed for the display of the HDR radiance image. By solving the high-order polynomial, the CRF can be recovered quickly and easily. Taken the local image feature and characteristic of histogram statics into consideration, the proposed TM operator could preserve the local details efficiently. Experimental result demonstrates the effectiveness of our method. By comparison, the method outperforms other methods in terms of imaging quality.

  18. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  19. Modeling the impact of preflushing on CTE in proton irradiated CCD-based detectors

    Science.gov (United States)

    Philbrick, R. H.

    2002-04-01

    A software model is described that performs a "real world" simulation of the operation of several types of charge-coupled device (CCD)-based detectors in order to accurately predict the impact that high-energy proton radiation has on image distortion and modulation transfer function (MTF). The model was written primarily to predict the effectiveness of vertical preflushing on the custom full frame CCD-based detectors intended for use on the proposed Kepler Discovery mission, but it is capable of simulating many other types of CCD detectors and operating modes as well. The model keeps track of the occupancy of all phosphorous-silicon (P-V), divacancy (V-V) and oxygen-silicon (O-V) defect centers under every CCD electrode over the entire detector area. The integrated image is read out by simulating every electrode-to-electrode charge transfer in both the vertical and horizontal CCD registers. A signal level dependency on the capture and emission of signal is included and the current state of each electrode (e.g., barrier or storage) is considered when distributing integrated and emitted signal. Options for performing preflushing, preflashing, and including mini-channels are available on both the vertical and horizontal CCD registers. In addition, dark signal generation and image transfer smear can be selectively enabled or disabled. A comparison of the charge transfer efficiency (CTE) data measured on the Hubble space telescope imaging spectrometer (STIS) CCD with the CTE extracted from model simulations of the STIS CCD show good agreement.

  20. First observations from a CCD all-sky spectrograph at Barentsburg (Spitsbergen

    Directory of Open Access Journals (Sweden)

    S. A. Chernouss

    2008-05-01

    Full Text Available A digital CCD all-sky spectrograph was made by the Polar Geophysical Institute (PGI to support IPY activity in auroral research. The device was tested at the Barentsburg observatory of PGI during the winter season of 2005–2006. The spectrograph is based on a cooled CCD and a transmission grating. The main features of this spectrograph are: a wide field of view (~180°, a wide spectral range (380–740 nm, a spectral resolution of 0.6 nm, a background level of about 100 R at 1-min exposure time. Several thousand spectra of nightglow and aurora were recorded during the observation season. It was possible to register both the strong auroral emissions, as well as weak ones. Spectra of aurora, including nitrogen and oxygen molecular and atomic emissions, as well as OH emissions of the nightglow are shown. A comparison has been conducted of auroral spectra obtained by the film all-sky spectral camera C-180-S at Spitsbergen during IGY, with spectra obtained at Barentsburg during the last winter season. The relationship between the red (630.0 nm and green (557.7 nm auroral emissions shows that the green emission is dominant near the minimum of the solar cycle activity (2005–2006. The opposite situation is observed during 1958–1959, with a maximum solar cycle activity.

  1. Deflection control system for prestressed concrete bridges by CCD camera. CCD camera ni yoru prestressed concrete kyo no tawami kanri system

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Y.; Nakayama, Y.; Arai, T. (Kawada Construction Co. Ltd., Tokyo (Japan))

    1994-03-15

    For the long-span prestressed concrete bridge (continuous box girder and cable stayed bridge), the design and construction control becomes increasingly complicated as construction proceeds because of its cyclic works. This paper describes the method and operation of an automatic levelling module using CCD camera and the experimental results by this system. For this automatic levelling system, the altitude can be automatically measured by measuring the center location of gravity of the target on the bridge surface using CCD camera. The present deflection control system developed compares the measured value by the automatic levelling system with the design value obtained by the design calculation system, and manages them. From the real-time continuous measurement for the long term, in which the CCD camera was set on the bridge surface, it was found that the stable measurement accuracy can be obtained. Successful application of this system demonstrates that the system is an effective and efficient construction aid. 11 refs., 19 figs., 1 tab.

  2. One method for HJ-1-A HSI and CCD data fusion

    International Nuclear Information System (INIS)

    Xiong, Wencheng; Shao, Yun; Shen, Wenming; Xiao, Rulin; Fu, Zhuo; Shi, Yuanli

    2014-01-01

    HJ-1-A satellite, developed by China independently, was equipped with two sensors of Hyper Spectral Imager (HSI) and multispectral sensor (CCD). In this paper, we examine the benefits of combining data from CCD data (high-spatial-resolution, low-spectral-resolution image) with HSI data (low -spatial-resolution, high -spectral-resolution image). Due to the same imaging time and similar spectral regime, the CCD and HSI data can be registered with each other well, and the difference between CCD and HSI data mainly is systematic bias. The approach we have been investigating compares the spectral information present in the multispectral image to the spectral content in the hyperspectral image, and derives a set of equations to approximately acquire the systematic bias between the two sensors. The systematic bias is then applied to the interpolated high-spectral CCD image to produce a fused product. This fused image has the spectral resolution of the hyperspectral image (HSI) and the spatial resolution of the multispectral image (CCD). It is capable of full exploitation as a hyperspectral image. We evaluate this technique using the data of Honghe wetland and show both good spectral and visual fidelity. An analysis of SAM classification test case shows good result when compared to original image. All in all, the approach we developed here provides a means for fusing data from HJ-1-A satellite to produce a spatial-resolution-enhanced hyperspectral data cube that can be further analyzed by spectral classification and detection algorithms

  3. Glyphosate accumulation, translocation, and biological effects in Coffea arabica after single and multiple exposures

    DEFF Research Database (Denmark)

    Schrübbers, Lars Christoph; Valverde, Bernal E.; Strobel, Bjarne W.

    2016-01-01

    In perennial crops like coffee, glyphosate drift exposure can occur multiple times during its commercial life span. Due to limited glyphosate degradation in higher plants, a potential accumulation of glyphosate could lead to increased biological effects with increased exposure frequency....... In this study, we investigated glyphosate translocation over time, and its concentration and biological effects after single and multiple simulated spray-drift exposures. Additionally, shikimic acid/glyphosate ratios were used as biomarkers for glyphosate binding to its target enzyme.Four weeks after...... the exposure, glyphosate was continuously translocated. Shikimic acid levels were lin-ear correlated with glyphosate levels. After two months, however, glyphosate appeared to have reduced activity. In the greenhouse, multiple applications resulted in higher internal glyphosate concentrations.The time...

  4. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  5. Noise analysis for CCD-based ultraviolet and visible spectrophotometry.

    Science.gov (United States)

    Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P

    2015-09-20

    We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4)  AU for the AvaSpec-3648 and 5.6×10(-4)  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.

  6. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  7. Single-Electron and Single-Photon Sensitivity with a Silicon Skipper CCD

    Science.gov (United States)

    Tiffenberg, Javier; Sofo-Haro, Miguel; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien

    2017-09-01

    We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068 e- rms /pixel . This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while future astronomical applications may include direct imaging and spectroscopy of exoplanets.

  8. Toxicity assessment of unintentional exposure to multiple chemicals

    International Nuclear Information System (INIS)

    Mumtaz, M.M.; Ruiz, P.; De Rosa, C.T.

    2007-01-01

    Typically exposure to environmental chemicals is unintentional, and often the exposure is to chemical mixtures, either simultaneously or sequentially. When exposure occurs, in public health practice, it is prudent to ascertain if thresholds for harmful health effects are exceeded, whether by individual chemicals or by chemicals in combination. Three alternative approaches are available for assessing the toxicity of chemical mixtures. Each approach, however, has shortcomings. As the procedures of each approach are described in this paper, at various steps research needs are identified. Recently, reliance has increased on computational toxicology methods for predicting toxicological effects when data are limited. Advances in molecular biology, identification of biomarkers, and availability of accurate and sensitive methods allow us to more precisely define the relationships between multiple chemical exposures and health effects, both qualitatively and quantitatively. Key research needs are best fulfilled through collaborative research. It is through such collaborations that resources are most effectively leveraged to further develop and apply toxicity assessment methods that advance public health practices in vulnerable communities

  9. Taking Multiple Exposure Into Account Can Improve Assessment of Chemical Risks.

    Science.gov (United States)

    Clerc, Frédéric; Bertrand, Nicolas Jean Hyacinthe; La Rocca, Bénédicte

    2017-12-15

    During work, operators may be exposed to several chemicals simultaneously. Most exposure assessment approaches only determine exposure levels for each substance individually. However, such individual-substance approaches may not correctly estimate the toxicity of 'cocktails' of chemicals, as the toxicity of a cocktail may differ from the toxicity of substances on their own. This study presents an approach that can better take into account multiple exposure when assessing chemical risks. Almost 30000 work situations, monitored between 2005 and 2014 and recorded in two French databases, were analysed using MiXie software. The algorithms employed in MiXie can identify toxicological classes associated with several substances, based on the additivity of the selected effects of each substance. The results of our retrospective analysis show that MiXie was able to identify almost 20% more potentially hazardous situations than identified using a single-substance approach. It therefore appears essential to review the ways in which multiple exposure is taken into account during risk assessment. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  10. Research of optical coherence tomography microscope based on CCD detector

    Science.gov (United States)

    Zhang, Hua; Xu, Zhongbao; Zhang, Shuomo

    2008-12-01

    The reference wave phase was modulated with a sinusoidal vibrating mirror attached to a Piezoelectric Transducer (PZT), the integration was performed by a CCD, and the charge storage period of the CCD image sensor was one-quarter period of the sinusoidal phase modulation. With the frequency- synchronous detection technique, four images (four frames of interference pattern) were recorded during one period of the phase modulation. In order to obtain the optimum modulation parameter, the values of amplitude and phase of the sinusoidal phase modulation were determined by considering the measurement error caused by the additive noise contained in the detected values. The PZT oscillation was controlled by a closed loop control system based on PID controller. An ideal discrete digital sine function at 50Hz with adjustable amplitude was used to adjust the vibrating of PZT, and a digital phase shift techniques was used to adjust vibrating phase of PZT so that the phase of the modulation could reach their optimum values. The CCD detector was triggered with software at 200Hz. Based on work above a small coherent signal masked by the preponderant incoherent background with a CCD detector was obtained.

  11. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    International Nuclear Information System (INIS)

    Freiesleben, Trine; Sohbati, Reza; Murray, Andrew; Jain, Mayank; Al Khasawneh, Sahar; Hvidt, Søren; Jakobsen, Bo

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescence–depth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated luminescence-depth profile from a feldspar-rich granite cobble from an archaeological site near Aarhus, Denmark. This profile shows qualitative evidence for multiple daylight exposure and burial events; these are quantified using the model developed here. By determining the burial ages from the surface layer of the cobble and by fitting the new model to the luminescence profile, it is concluded that the cobble was well bleached before burial. This indicates that the OSL burial age is likely to be reliable. In addition, a recent known exposure event provides an approximate calibration for older daylight exposure events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible to determine the length of a fossil exposure, using a known natural light exposure as calibration. - Highlights: • Evidence for multiple exposure and burial events in the history of a single cobble. • OSL rock surface dating model improved to include multiple burial/exposure cycles. • Application of the new model quantifies burial and exposure events.

  12. Temperature changes across porcelain during multiple exposure CO2 lasing

    Science.gov (United States)

    Barron, Joseph R.; Zakariasen, Kenneth L.; Peacocke, Larry

    1990-06-01

    Research indicates that laser energy may provide a useful method for glazing and fusing porcelain for intraoral prosthetic purposes. However, it is not known whether such lasing will result in the production of heat levels that may be damaging to adjacent vital tissues such as the dental pulp and periodontal tissues. This research is designed to measure the magnitude of temperature rise across porcelain observed during multiple exposure C02 lasing. Fifteen porcelain examples of 1000 jim (5), 1500 pm (5) and 2000 tm (5) x each received five C02 laser exposures on the same exposure site at 1.0 sec. intervals at 8.0 watts (0.2 sec. per exposure with a 1 mm focal spot). A YSI 144201 thermilinear precision thermistor was placed on the porcelain surface opposite each laser exposure site. Temperature rise above ambient was recorded by an HP3421A data acquisition unit and HP9816 technical microcomputer. Recording continued for sufficient time to allow temperatures to return to ambient. The mean temperature elevations ranged from a low of 2.97 0C (2000 pm) to a high of 7.77 °C (1000 μm). ANOVA and Duncan's Multiple Range Test indicated significant differences in temperature rise by porcelain thickness. It would appear from the results of this research that temperature elevations adjacent to lased porcelain may be sufficiently controllable that safe intraoral porcelain lasing will be possible.

  13. Investigation of radiation damage effects in neutron irradiated CCD

    International Nuclear Information System (INIS)

    Brau, James E.; Igonkina, Olga; Potter, Chris T.; Sinev, Nikolai B.

    2005-01-01

    A Charge Coupled Devices (CCD)-based vertex detector is a leading option for vertex detection at the future linear collider. A major issue for this application is the radiation hardness of such devices. Tests of radiation hardness of CCDs used in the SLD vertex detector, VXD3, have been reported earlier. The first measurements of 1998 involved a spare VXD3 CCD that was irradiated with neutrons from a radioactive source (Pu-Be), and from a nuclear reactor. In 2003, we had the opportunity to disassemble the VXD3 detector and study the nature of the radiation damage it incurred during 3 years of operation at SLC. In the preparation for this study, additional experiments with the spare VXD3 CCD were performed. These included measurements of trapping times in neutron irradiated CCDs. Results, reported here, will help us better understand the mechanism of radiation damage effects and develop techniques to minimize performance degradation due to radiation damage

  14. Stroboscope Based Synchronization of Full Frame CCD Sensors.

    Science.gov (United States)

    Shen, Liang; Feng, Xiaobing; Zhang, Yuan; Shi, Min; Zhu, Dengming; Wang, Zhaoqi

    2017-04-07

    The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equipment, the proposed approach greatly reduces the cost by using inexpensive CCD cameras and one stroboscope. The results show that our method could reach a high accuracy much better than the frame-level synchronization of traditional software methods.

  15. The study of interferometer spectrometer based on DSP and linear CCD

    Science.gov (United States)

    Kang, Hua; Peng, Yuexiang; Xu, Xinchen; Xing, Xiaoqiao

    2010-11-01

    In this paper, general theory of Fourier-transform spectrometer and polarization interferometer is presented. A new design is proposed for Fourier-transform spectrometer based on polarization interferometer with Wollaston prisms and linear CCD. Firstly, measured light is changed into linear polarization light by polarization plate. And then the light can be split into ordinary and extraordinary lights by going through one Wollaston prism. At last, after going through another Wollaston prism and analyzer, interfering fringes can be formed on linear CCD behind the analyzer. The linear CCD is driven by CPLD to output amplitude of interfering fringes and synchronous signals of frames and pixels respectively. DSP is used to collect interference pattern signals from CCD and the digital data of interfering fringes are processed by using 2048-point-FFT. Finally, optical spectrum of measured light can be display on LCD connected to DSP with RS232. The spectrometer will possess the features of firmness, portability and the ability of real-time analyzing. The work will provide a convenient and significant foundation for application of more high accuracy of Fourier-transform spectrometer.

  16. A multiple objective test assembly approach for exposure control problems in Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    Theo J.H.M. Eggen

    2010-01-01

    Full Text Available Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has to be maximized, item compromise has to be minimized, and pool usage has to be optimized. In this paper, a multiple objectives method is developed to deal with both types of exposure problems. In this method, exposure control parameters based on observed exposure rates are implemented as weights for the information in the item selection procedure. The method does not need time consuming simulation studies, and it can be implemented conditional on ability level. The method is compared with Sympson Hetter method for exposure control, with the Progressive method and with alphastratified testing. The results show that the method is successful in dealing with both kinds of exposure problems.

  17. CCD-based thermoreflectance microscopy: principles and applications

    International Nuclear Information System (INIS)

    Farzaneh, M; Maize, K; Shakouri, A; Lueerssen, D; Summers, J A; Hudgings, Janice A; Mayer, P M; Ram, R J; Raad, P E; Pipe, K P

    2009-01-01

    CCD-based thermoreflectance microscopy has emerged as a high resolution, non-contact imaging technique for thermal profiling and performance and reliability analysis of numerous electronic and optoelectronic devices at the micro-scale. This thermography technique, which is based on measuring the relative change in reflectivity of the device surface as a function of change in temperature, provides high-resolution thermal images that are useful for hot spot detection and failure analysis, mapping of temperature distribution, measurement of thermal transient, optical characterization of photonic devices and measurement of thermal conductivity in thin films. In this paper we review the basic physical principle behind thermoreflectance as a thermography tool, discuss the experimental setup, resolutions achieved, signal processing procedures and calibration techniques, and review the current applications of CCD-based thermoreflectance microscopy in various devices. (topical review)

  18. Converting structures to optimize the Synchrotron X radiation detection by CCD systems

    International Nuclear Information System (INIS)

    Zanella, G.; Zannoni, R.

    1987-01-01

    It is pointed out how the quantum efficiency of X ray detection for CCD detecting system can be improved enlarging their sensivity range by means of heavy element converting structures. So the problem of fabricating CCD with a deep emptying layer is avoided

  19. Prevalence and predictors of exposure to multiple metals in preschool children from Montevideo, Uruguay

    International Nuclear Information System (INIS)

    Kordas, Katarzyna; Queirolo, Elena I.; Ettinger, Adrienne S.; Wright, Robert O.; Stoltzfus, Rebecca J.

    2010-01-01

    The extent of children's exposure to multiple toxic metals is not well described in many developing countries. We examined metal exposures in young children (6-37 months) from Montevideo, Uruguay and their mothers (15-47 years) participating in a community-based study. Hair samples collected from 180 children and their mothers were analyzed for: lead (Pb), cadmium (Cd), manganese (Mn), and arsenic (As) concentration using inductively coupled plasma-mass spectrometry (ICP-MS). Median metal levels (μg/g) were: Pb 13.69, Mn 1.45, Cd 0.17, and As 0.09 for children and Pb 4.27, Mn 1.42, Cd 0.08, and As 0.02 for mothers. Of the child and maternal samples, 1.7% and 2.9% were below the limit of detection (LOD) for Cd, and 21.3% and 38.5% were below the LOD for As, respectively. Correlations between maternal and child levels ranged 0.38-0.55 (p < 0.01). Maternal hair metal levels were the strongest predictors of metal concentrations in children's hair. Girls had significantly lower As levels than boys (p < 0.01) but did not differ on other metals. In addition, in bivariate logistic regressions predicting the likelihood that the child would be exposed to multiple metals, hemoglobin < 10.5 g/dL (OR = 2.12, p < 0.05), blood lead (OR = 1.17, p < 0.01), and the mother being exposed to two or more metals (OR = 3.34, p < 0.01) were identified as significant predictors of increased likelihood of multiple metal exposure. Older child age (OR = 0.96, p < 0.05), higher maternal education (OR = 0.35, p < 0.01), and higher number of household possessions (OR = 0.83, p < 0.01) were significantly associated with decreased likelihood of multiple metal exposure. Preschool children in Uruguay are exposed to multiple metals at levels that in other studies have been associated with cognitive and behavioral deficits. Sources of exposure, as well as cognitive and behavioral consequences of multiple metal exposure, should be investigated in this population.

  20. Prevalence and predictors of exposure to multiple metals in preschool children from Montevideo, Uruguay

    Energy Technology Data Exchange (ETDEWEB)

    Kordas, Katarzyna, E-mail: Kxk48@psu.edu [Department of Nutritional Sciences, Pennsylvania State University, 110 Chandlee Laboratory, University Park, PA 16802 (United States); Queirolo, Elena I. [Center for Research, Catholic University of Uruguay, Montevideo (Uruguay); Clinic for Environmental Contaminants, Pereira Rossell Hospital, Montevideo (Uruguay); Ettinger, Adrienne S.; Wright, Robert O. [Department of Environmental Health, Harvard School of Public Health, Boston, MA (United States); Stoltzfus, Rebecca J. [Division of Nutritional Sciences, Cornell University, Ithaca, NY (United States)

    2010-09-15

    The extent of children's exposure to multiple toxic metals is not well described in many developing countries. We examined metal exposures in young children (6-37 months) from Montevideo, Uruguay and their mothers (15-47 years) participating in a community-based study. Hair samples collected from 180 children and their mothers were analyzed for: lead (Pb), cadmium (Cd), manganese (Mn), and arsenic (As) concentration using inductively coupled plasma-mass spectrometry (ICP-MS). Median metal levels ({mu}g/g) were: Pb 13.69, Mn 1.45, Cd 0.17, and As 0.09 for children and Pb 4.27, Mn 1.42, Cd 0.08, and As 0.02 for mothers. Of the child and maternal samples, 1.7% and 2.9% were below the limit of detection (LOD) for Cd, and 21.3% and 38.5% were below the LOD for As, respectively. Correlations between maternal and child levels ranged 0.38-0.55 (p < 0.01). Maternal hair metal levels were the strongest predictors of metal concentrations in children's hair. Girls had significantly lower As levels than boys (p < 0.01) but did not differ on other metals. In addition, in bivariate logistic regressions predicting the likelihood that the child would be exposed to multiple metals, hemoglobin < 10.5 g/dL (OR = 2.12, p < 0.05), blood lead (OR = 1.17, p < 0.01), and the mother being exposed to two or more metals (OR = 3.34, p < 0.01) were identified as significant predictors of increased likelihood of multiple metal exposure. Older child age (OR = 0.96, p < 0.05), higher maternal education (OR = 0.35, p < 0.01), and higher number of household possessions (OR = 0.83, p < 0.01) were significantly associated with decreased likelihood of multiple metal exposure. Preschool children in Uruguay are exposed to multiple metals at levels that in other studies have been associated with cognitive and behavioral deficits. Sources of exposure, as well as cognitive and behavioral consequences of multiple metal exposure, should be investigated in this population.

  1. SU-F-BRA-16: Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Taneja, S; Fru, L Che; Desai, V; Lentz, J; Lin, C; Scarpelli, M; Simiele, E; Trestrail, A; Bednarz, B [University of Wisconsin, Madison, WI (United States)

    2015-06-15

    Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Apple iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.

  2. Design of area array CCD image acquisition and display system based on FPGA

    Science.gov (United States)

    Li, Lei; Zhang, Ning; Li, Tianting; Pan, Yue; Dai, Yuming

    2014-09-01

    With the development of science and technology, CCD(Charge-coupled Device) has been widely applied in various fields and plays an important role in the modern sensing system, therefore researching a real-time image acquisition and display plan based on CCD device has great significance. This paper introduces an image data acquisition and display system of area array CCD based on FPGA. Several key technical challenges and problems of the system have also been analyzed and followed solutions put forward .The FPGA works as the core processing unit in the system that controls the integral time sequence .The ICX285AL area array CCD image sensor produced by SONY Corporation has been used in the system. The FPGA works to complete the driver of the area array CCD, then analog front end (AFE) processes the signal of the CCD image, including amplification, filtering, noise elimination, CDS correlation double sampling, etc. AD9945 produced by ADI Corporation to convert analog signal to digital signal. Developed Camera Link high-speed data transmission circuit, and completed the PC-end software design of the image acquisition, and realized the real-time display of images. The result through practical testing indicates that the system in the image acquisition and control is stable and reliable, and the indicators meet the actual project requirements.

  3. A Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Software

    Directory of Open Access Journals (Sweden)

    S. H. Oh

    2007-12-01

    Full Text Available We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E (768×512, KAF-1602E (15367times;1024, KAF-3200E (2184×1472 made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.

  4. Design of offline measuring system for radiation damage effects on linear CCD

    International Nuclear Information System (INIS)

    Zhang Yong; Tang Benqi; Xiao Zhigang; Wang Zujun; Huang Fang; Huang Shaoyan

    2004-01-01

    The paper discusses the hardware design of offline measuring system for radiation damage effects on linear CCD. Some credible results were achieved by using this system. The test results indicate that the system is available for the study of the radiation damage effects on linear CCD. (authors)

  5. Automated CCD camera characterization. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Silbermann, J.

    1999-03-01

    The OMEGA system uses CCD cameras for a broad range of applications. Over 100 video rate CCD cameras are used for such purposes as targeting, aligning, and monitoring areas such as the target chamber, laser bay, and viewing gallery. There are approximately 14 scientific grade CCD cameras on the system which are used to obtain precise photometric results from the laser beam as well as target diagnostics. It is very important that these scientific grade CCDs are properly characterized so that the results received from them can be evaluated appropriately. Currently characterization is a tedious process done by hand. The operator must manually operate the camera and light source simultaneously. Because more exposures means more accurate information on the camera, the characterization tests can become very length affairs. Sometimes it takes an entire day to complete just a single plot. Characterization requires the testing of many aspects of the camera's operation. Such aspects include the following: variance vs. mean signal level--this should be proportional due to Poisson statistics of the incident photon flux; linearity--the ability of the CCD to produce signals proportional to the light it received; signal-to-noise ratio--the relative magnitude of the signal vs. the uncertainty in that signal; dark current--the amount of noise due to thermal generation of electrons (cooling lowers this noise contribution significantly). These tests, as well as many others, must be conducted in order to properly understand a CCD camera. The goal of this project was to construct an apparatus that could characterize a camera automatically

  6. Optimization of polarimetry sensitivity for X-ray CCD

    CERN Document Server

    Hayashida, K; Tsunemi, H; Hashimoto, Y; Ohtani, M

    1999-01-01

    X-ray polarimetry with CCD has been performed using a polarized X-ray beam from an electron impact X-ray source. The standard data reduction method employing double-pixel events yields the modulation factor M of 0.14 at 27 keV and 0.24 at 43 keV for the 12 mu m pixel size CCD chip. We develop a new data reduction method, in which multi-pixel events are employed, and which approximates the charge spread as an oval shape. We optimize the reduction parameters, so that we improve the P sub m sub i sub n (minimum detectable polarization degree) by factor of three from the value obtained through the usual double-pixel event method.

  7. Stroboscope Based Synchronization of Full Frame CCD Sensors

    Directory of Open Access Journals (Sweden)

    Liang Shen

    2017-04-01

    Full Text Available The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equipment, the proposed approach greatly reduces the cost by using inexpensive CCD cameras and one stroboscope. The results show that our method could reach a high accuracy much better than the frame-level synchronization of traditional software methods.

  8. Modelling charge storage in Euclid CCD structures

    International Nuclear Information System (INIS)

    Clarke, A S; Holland, A; Hall, D J; Burt, D

    2012-01-01

    The primary aim of ESA's proposed Euclid mission is to observe the distribution of galaxies and galaxy clusters, enabling the mapping of the dark architecture of the universe [1]. This requires a high performance detector, designed to endure a harsh radiation environment. The e2v CCD204 image sensor was redesigned for use on the Euclid mission [2]. The resulting e2v CCD273 has a narrower serial register electrode and transfer channel compared to its predecessor, causing a reduction in the size of charge packets stored, thus reducing the number of traps encountered by the signal electrons during charge transfer and improving the serial Charge Transfer Efficiency (CTE) under irradiation [3]. The proposed Euclid CCD has been modelled using the Silvaco TCAD software [4], to test preliminary calculations for the Full Well Capacity (FWC) and the channel potential of the device and provide indications of the volume occupied by varying signals. These results are essential for the realisation of the mission objectives and for radiation damage studies, with the aim of producing empirically derived formulae to approximate signal-volume characteristics in the devices. These formulae will be used in the radiation damage (charge trapping) models. The Silvaco simulations have been tested against real devices to compare the experimental measurements to those predicted in the models. Using these results, the implications of this study on the Euclid mission can be investigated in more detail.

  9. Stellar CCD Photometry: New Approach, Principles and Application

    Science.gov (United States)

    El-Bassuny Alawy, A.

    A new approach is proposed and developed to handle pre-processed CCD frames in order to identify stellar images and derive their relevant parameters. It relies on: 1) Identifying stellar images and assigning approximate positions of their centres using an artificial intelligence technique, (Knowledge Based System), 2) Accurate determination of the centre co-ordinates applying an elementary statistical concept and 3) Estimating the image peak intensity as a stellar magnitude measure employing simple numerical analysis approach. The method has been coded for personal computer users. A CCD frame of the star cluster M67 was adopted as a test case. The results obtained are discussed in comparison with the DAOPHOTII ones and the corresponding published data. Exact coincidence has been found between both results except in very few cases. These exceptions have been discussed in the light of the basis of both methods and the cluster plates. It has been realised that the method suggested represents a very simple, extremely fast, high precision method of stellar CCD photometry. Moreover, it is more capable than DAOPHOTII of handling blended and distorted stellar images. These characteristics show the usefulness of the present method in some astronomical applications, such as auto-focusing and auto-guiding, beside the main purpose, viz. stellar photometry.

  10. Optical CT scanning of PRESAGETM polyurethane samples with a CCD-based readout system

    International Nuclear Information System (INIS)

    Doran, S J; Krstajic, N; Adamovics, J; Jenneson, P M

    2004-01-01

    This article demonstrates the resolution capabilities of the CCD scanner under ideal circumstances and describes the first CCD-based optical CT experiments on a new class of dosimeter, known as PRESAGE TM (Heuris Pharma, Skillman, NJ)

  11. On-Line High Dose-Rate Gamma Ray Irradiation Test of the CCD/CMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    In this paper, test results of gamma ray irradiation to CCD/CMOS cameras are described. From the CAMS (containment atmospheric monitoring system) data of Fukushima Dai-ichi nuclear power plant station, we found out that the gamma ray dose-rate when the hydrogen explosion occurred in nuclear reactors 1{approx}3 is about 160 Gy/h. If assumed that the emergency response robot for the management of severe accident of the nuclear power plant has been sent into the reactor area to grasp the inside situation of reactor building and to take precautionary measures against releasing radioactive materials, the CCD/CMOS cameras, which are loaded with the robot, serve as eye of the emergency response robot. In the case of the Japanese Quince robot system, which was sent to carry out investigating the unit 2 reactor building refueling floor situation, 7 CCD/CMOS cameras are used. 2 CCD cameras of Quince robot are used for the forward and backward monitoring of the surroundings during navigation. And 2 CCD (or CMOS) cameras are used for monitoring the status of front-end and back-end motion mechanics such as flippers and crawlers. A CCD camera with wide field of view optics is used for monitoring the status of the communication (VDSL) cable reel. And another 2 CCD cameras are assigned for reading the indication value of the radiation dosimeter and the instrument. In the preceding assumptions, a major problem which arises when dealing with CCD/CMOS cameras in the severe accident situations of the nuclear power plant is the presence of high dose-rate gamma irradiation fields. In the case of the DBA (design basis accident) situations of the nuclear power plant, in order to use a CCD/CMOS camera as an ad-hoc monitoring unit in the vicinity of high radioactivity structures and components of the nuclear reactor area, a robust survivability of this camera in such intense gamma-radiation fields therefore should be verified. The CCD/CMOS cameras of various types were gamma irradiated at a

  12. [Multiple mere exposure effect: category evaluation measured in the Go/No-go association task (GNAT)].

    Science.gov (United States)

    Kawakami, Naoaki; Yoshida, Fujio

    2011-12-01

    The effect on likability of multiple subliminal exposures to the same person was investigated. Past studies on the mere exposure effect indicated a correlation between the frequency of repeated exposure to the same stimulus and likability. We proposed that exposure to various stimuli of the same person would have a stronger effect on likability. Participants were subliminally exposed to photographs of a person's face taken from seven angles (multi-angle-exposure) three times each (Experiment 1), or photographs of a person with seven facial expressions (multi-expression-exposure) three times each (Experiment 2). Then, the likability toward the exposed person was measured using the Go/No-go Association Task. The results indicated that the effect of the multiple exposures from various angles was equivalent to exposure to only one full-face photograph shown 21 times (Experiment 1). Moreover, likability was significantly higher in the case of exposure to various facial expressions than for exposure to only a single facial expression (Experiment 2). The results suggest that exposure to various stimuli in a category is more effective than repeated exposure to a single stimulus for increasing likability.

  13. Multiple exposure routes of a pesticide exacerbate effects on a grazing mayfly.

    Science.gov (United States)

    Pristed, Mathias Joachim Skov; Bundschuh, Mirco; Rasmussen, Jes Jessen

    2016-09-01

    Hydrophobic pesticides such as pyrethroid insecticides tend to occur in their soluble form mainly as transient pulses in streams. In addition, they are regularly detected in significant quantities adsorbed to stream sediments and other organic in-stream structures. Consequently, stream biota is likely subjected to pesticide exposure via multiple routes. In this study we aimed at investigating the influence of exposure routes for the pyrethroid insecticide lambda-cyhalothrin on the grazing mayfly Heptagenia sulphurea. Therefore, H. sulphurea was exposed to lambda-cyhalothrin via single- (water or biofilm) or biphasic exposure (water and biofilm) at environmentally realistic concentrations (0, 0.1, 1μgL(-1)) and exposure duration (2h) in a full factorial design (n=5). Mortality, moulting frequency, and biofilm accrual (proxy for feeding rate) were recorded subsequent to a 7 d post exposure period. Mortality significantly increased and moulting frequency significantly decreased with increasing concentrations of lambda-cyhalothrin in the water phase whereas exposure via biofilm prompted no significant effects on these endpoints (α=0.05). Effect predictions systematically underestimated and overestimated effects for mortality and moulting frequency, respectively. Similarly, mayfly feeding rate was significantly reduced by water phase exposure whereas pre-exposed biofilm did not significantly affect this variable. However, we found a significant but non-systematic interaction between water phase and biofilm exposure on mayfly feeding rate. Our results show that exposure to the same pesticide via multiple exposure routes may increase the magnitude of effects beyond the level predicted from single phase exposures which has clear implications for the aquatic risk assessment of hydrophobic pesticides. However, our results additionally reveal that interactions between pesticide exposure routes may vary between selected dependent variables. We emphasize that unravelling the

  14. Ultrahigh-speed, high-sensitivity color camera with 300,000-pixel single CCD

    Science.gov (United States)

    Kitamura, K.; Arai, T.; Yonai, J.; Hayashida, T.; Ohtake, H.; Kurita, T.; Tanioka, K.; Maruyama, H.; Namiki, J.; Yanagi, T.; Yoshida, T.; van Kuijk, H.; Bosiers, Jan T.; Etoh, T. G.

    2007-01-01

    We have developed an ultrahigh-speed, high-sensitivity portable color camera with a new 300,000-pixel single CCD. The 300,000-pixel CCD, which has four times the number of pixels of our initial model, was developed by seamlessly joining two 150,000-pixel CCDs. A green-red-green-blue (GRGB) Bayer filter is used to realize a color camera with the single-chip CCD. The camera is capable of ultrahigh-speed video recording at up to 1,000,000 frames/sec, and small enough to be handheld. We also developed a technology for dividing the CCD output signal to enable parallel, highspeed readout and recording in external memory; this makes possible long, continuous shots up to 1,000 frames/second. As a result of an experiment, video footage was imaged at an athletics meet. Because of high-speed shooting, even detailed movements of athletes' muscles were captured. This camera can capture clear slow-motion videos, so it enables previously impossible live footage to be imaged for various TV broadcasting programs.

  15. A tilted fiber-optic plate coupled CCD detector for high resolution neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongyul; Cho, Gyuseong [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jongyul; Hwy, Limchang; Kim, Taejoo; Lee, Kyehong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Seungwook [Pusan National Univ., Pusan (Korea, Republic of)

    2013-05-15

    One of these efforts is that a tilted scintillator geometry and lens coupled CCD detector for neutron imaging system were used to improve spatial resolution in one dimension. The increased spatial resolution in one dimension was applied to fuel cell study. However, a lens coupled CCD detector has lower sensitivity than a fiber-optic plate coupled CCD detector due to light loss. In this research, a tilted detector using fiber-optic plate coupled CCD detector was developed to improve resolution and sensitivity. In addition, a tilted detector can prevent an image sensor from direct radiation damage. Neutron imaging has been used for fuel cell study, lithium ion battery study, and many scientific applications. High quality neutron imaging is demanded for more detailed studies of applications, and spatial resolution should be considered to get high quality neutron imaging. Therefore, there were many efforts to improve spatial resolution.

  16. Calibration of the CCD photonic measuring system for railway inspection

    Science.gov (United States)

    Popov, D. V.; Ryabichenko, R. B.; Krivosheina, E. A.

    2005-08-01

    Increasing of traffic speed is the most important task in Moscow Metro. Requirements for traffic safety grow up simultaneously with the speed increasing. Currently for track inspection in Moscow Metro is used track measurement car has built in 1954. The main drawbacks of this system are absence of automated data processing and low accuracy. Non-contact photonic measurement system (KSIR) is developed for solving this problem. New track inspection car will be built in several months. This car will use two different track inspection systems and car locating subsystem based on track circuit counting. The KSIR consists of four subsystems: rail wear, height and track gauge measurement (BFSM); rail slump measurement (FIP); contact rail measurement (FKR); speed, level and car locating (USI). Currently new subsystem for wheel flange wear (IRK) is developed. The KSIR carry out measurements in real-time mode. The BFSM subsystem contains 4 matrix CCD cameras and 4 infrared stripe illuminators. The FIP subsystem contains 4 line CCD cameras and 4 spot illuminators. The FKR subsystem contains 2 matrix CCD cameras and 2 stripe illuminators. The IRK subsystem contains 2 CCD cameras and 2 stripe illuminators. Each system calibration was carried out for their adjustment. On the first step KSIR obtains data from photonic sensors which is valued in internal measurement units. Due to the calibration on the second step non-contact system converts the data to metric measurement system.

  17. Digital Printing Quality Detection and Analysis Technology Based on CCD

    Science.gov (United States)

    He, Ming; Zheng, Liping

    2017-12-01

    With the help of CCD digital printing quality detection and analysis technology, it can carry out rapid evaluation and objective detection of printing quality, and can play a certain control effect on printing quality. It can be said CDD digital printing quality testing and analysis of the rational application of technology, its digital printing and printing materials for a variety of printing equipments to improve the quality of a very positive role. In this paper, we do an in-depth study and discussion based on the CCD digital print quality testing and analysis technology.

  18. Experience in CCD Photometry at the Tartu Observatory

    Directory of Open Access Journals (Sweden)

    Tuvikene T.

    2003-12-01

    Full Text Available We give overview of the CCD instrumentation and data reduction techniques used at the Tartu Observatory. The first results from photometric observations of the peculiar variable V838 Mon are presented.

  19. Application of X-ray CCD camera in X-ray spot diagnosis of rod-pinch diode

    International Nuclear Information System (INIS)

    Song Yan; Zhou Ming; Song Guzhou; Ma Jiming; Duan Baojun; Han Changcai; Yao Zhiming

    2015-01-01

    The pinhole imaging technique is widely used in the measurement of X-ray spot of rod-pinch diode. The X-ray CCD camera, which was composed of film, fiber optic taper and CCD camera, was employed to replace the imaging system based on scintillator, lens and CCD camera in the diagnosis of X-ray spot. The resolution of the X-ray CCD camera was studied. The resolution is restricted by the film and is 5 lp/mm in the test with Pb resolution chart. The frequency is 1.5 lp/mm when the MTF is 0.5 in the test with edge image. The resolution tests indicate that the X-ray CCD camera can meet the requirement of the diagnosis of X-ray spot whose scale is about 1.5 mm when the pinhole imaging magnification is 0.5. At last, the image of X-ray spot was gained and the restoration was implemented in the diagnosis of X-ray spot of rod-pinch diode. (authors)

  20. Mapping the future: U.S. exposure to multiple landscape stressors

    Science.gov (United States)

    Marie Oliver; Becky Kerns; John Kim; Jeff. Kline

    2017-01-01

    Landscape exposure to multiple stressors can pose risks to human health, biodiversity, and ecosystem services. Attempts to study, control, or mitigate these stressors can strain public and private budgets. An interdisciplinary team of Pacific Northwest Research Station and Oregon State University scientists created maps of the conterminous United States that indicate...

  1. Temperature changes across CO2-lased dentin during multiple exposures

    Science.gov (United States)

    Zakariasen, Kenneth L.; Barron, Joseph R.; Boran, Thomas L.

    1990-06-01

    The literature increasingly indicates that lasers will have a multitude of applications for dental hard tissue procedures, e.g. preventive therapy, caries removal, laser etching and endodontic therapy. However, it is critical that such laser therapies avoid the production of heat levels which will be damaging to the surrounding vital tissues, such as the dental pulp and periodontal tissues. Our preliminary research on temperature changes across C02 lased dentin indicated that for single preventive therapeutic exposures (1.2 W., 0. 1 sec., 1.0 mm focal spot) the mean temperature rise across 350 j.tm of dentin was 0.57 0C while across 1000 .tm of dentin the mean rise was only 0.18 °C. Further research utilizing multiple preventive therapeutic exposures (1.2 W., 0. 1 sec., 1.0 mm focal spot, 3 x 1.0 sec. intervals) showed mean temperature elevations of 1.56 0C across 350 m of dentin and 0.66 O across 1000 xm of dentin. While these temperature elevations, which would be associated with preventive therapy, are very low and would be biologically acceptable, it must be noted that exposures of higher intensities are required to fuse enamel and porcelain, or remove decay. This current research investigates temperature elevations which occuT during C02 lasing utilizing the following exposure parameters: 8.0 W., 1.0 mm focal spot, 0.1 sec. exposures, 2 or 4 exposures per site pulsed 1.0 sec. apart. Three dentin thicknesses were utilized, i.e. 1000 jim, 1500 p.tm and 2000 .tm. Four sections of each thickness were utilized with four exposure sites per specimen (2 with 2 exposures, 2 with 4 exposures). All dentin sections were prepared from non-carious third molars using a hard tissue microtome. A thermistor was placed on the dentin surface opposite each lased site and temperature changes were recorded for approximately 50 sec. following lasing. Mean temperature elevations ranged from a high of 3.07 C for the 1000 xm section utilizing four exposures to a low of 0.37 0C for the

  2. A GRAPH READER USING A CCD IMAGE SENSOR

    African Journals Online (AJOL)

    2008-01-18

    Jan 18, 2008 ... using a stepper motor controlled by a software program in a ... Keywords: CCD sensor, microcontrollen stepper motor and microcomputer. 1. ... commercial applications (Awcock and ... on-chip amplifier, one pixel at a tirtjie.

  3. C.C.D. readout of a picosecond streak camera with an intensified C.C.D

    International Nuclear Information System (INIS)

    Lemonier, M.; Richard, J.C.; Cavailler, C.; Mens, A.; Raze, G.

    1984-08-01

    This paper deals with a digital streak camera readout device. The device consists in a low light level television camera made of a solid state C.C.D. array coupled to an image intensifier associated to a video-digitizer coupled to a micro-computer system. The streak camera images are picked-up as a video signal, digitized and stored. This system allows the fast recording and the automatic processing of the data provided by the streak tube

  4. Correction of over and under exposure images using multiple lighting system

    International Nuclear Information System (INIS)

    Im, Jonghoon; Fujii, Hiromitsu; Yamashita, Atsushi; Asama, Hajime

    2015-01-01

    When images are acquired in bright condition, it can cause a loss of highlight details (over exposure) in bright area and a loss of shadow details (under exposure) in dark area. Over and under exposure causes a big problem when people investigate dangerous place like Fukushima nuclear power plant through the camera attached remote control robot. In this paper, we propose a method to correct the over and under exposure image to solve the problem. The image processing consists of four steps. Firstly, multiple images are acquired by alternately turning on and off each illumination which set in different positions. Then the image obtained first is defined as input image 1, the image obtained second is defined as input image 2 and the image obtained N-th is defined as input image N. Secondly, luminance of the images is corrected. Thirdly, over and under exposure regions in the image are extracted from the input image 1. Finally, the over and under exposure regions in the input image 1 are compensated by other images. The results show that the over and under exposure regions in the input image are recovered by our proposed method. (author)

  5. In-flight characterization of the HETE soft X-ray CCD cameras

    International Nuclear Information System (INIS)

    Prigozhin, G.; Villasenor, J.; Vanderspek, R.; Doty, J.; Crew, G.; Ricker, G.; Jernigan, G.

    2003-01-01

    We have developed a set of software tools that allow to monitor the performance of the flight X-ray CCD cameras as soon as data arrive at MIT. An emission line at 5.9 keV from the on-board Fe-55 radioactive calibration source is clearly visible in the spectra and provides the means to measure the gain and the noise for each observation in each of the 4 CCD chips in operation. Both parameters can change with time, depending on the phase of the moon and the amount of light leaking into the system. Time vs. position scatter plots were found to be an extremely powerful tool in understanding of the device performance. They illustrate the evolution of the light leaks produced by the dark Earth at the beginning and the end of each orbit. With a bright X-ray source in the field of view the shadow of the mask projected on the surface of the CCD clearly shows the motions of the spacecraft

  6. Protein diffraction experiments with Atlas CCD detector

    Czech Academy of Sciences Publication Activity Database

    Dohnálek, Jan; Kovaľ, Tomáš; Dušek, Michal

    2008-01-01

    Roč. 64, Suppl. - abstracts (2008), C192 ISSN 0108-7673. [Congress of the International Union of Crystallography (IUCr) /21./. 23.08.2008-31.08.2008, Osaka] Institutional research plan: CEZ:AV0Z10100521 Keywords : x-ray data collection * CCD detectors * protein crystallography applications Subject RIV: BM - Solid Matter Physics ; Magnetism

  7. Discussion on the fusing methods for HR and CCD images of CBERS

    International Nuclear Information System (INIS)

    Gao Zhangsheng; Zhao Yingjun

    2010-01-01

    CBERS-02B multi-spectral CCD data are different from HR panchromatic data in resolution, which causes difficulty in image fusion. With the method of Pansharping, HPF, Brovey transform, IHS transform, principal component transform, Gram Schmidt (GS) transform and wavelet transform, the authors have tested the fusion methods for CCD data and HR data of CBERS, and the fusion results are discussed and evaluated qualitatively and quantitatively. (authors)

  8. Comparison of entrance exposure and signal-to-noise ratio between an SBDX prototype and a wide-beam cardiac angiographic system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Star-Lack, Josh M.; Heanue, Joseph A.; Betts, Timothy D.; Van Lysel, Michael S.

    2006-01-01

    The scanning-beam digital x-ray (SBDX) system uses an inverse geometry, narrow x-ray beam, and a 2-mm thick CdTe detector to improve the dose efficiency of the coronary angiographic procedure. Entrance exposure and large-area iodine signal-to-noise ratio (SNR) were measured with the SBDX prototype and compared to that of a clinical cardiac interventional system with image intensifier (II) and charge coupled device (CCD) camera (Philips H5000, MRC-200 x-ray tube, 72 kWp max). Phantoms were 18.6-35.0 cm acrylic with an iohexol-equivalent disk placed at midthickness (35 mg/cm 2 iodine radiographic density). Imaging was performed at 15 frame/s, with the disk at mechanical isocenter and an 11-cm object-plane field width. The II/CCD system was operated in cine mode with automatic exposure control. With the SBDX prototype at maximum x-ray output (120 kVp, 24.3 kWp), the SBDX SNR was 107%-69% of the II/CCD SNR, depending on phantom thickness, and the SBDX entrance exposure rate was 10.7-9.3 R/min (9.4-8.2 cGy/min air kerma). For phantoms where an equal-kVp imaging comparison was possible (≥23.3 cm), the SBDX SNR ranged from 47% to 69% of the II/CCD SNR while delivering 6% to 9% of the II/CCD entrance exposure rate. From these measurements it was determined that the relative SBDX entrance exposure at equal SNR would be 31%-16%. Results were consistent with a model for relative entrance exposure at equal SNR, which predicted a 3-7 times reduction in entrance exposure due to SBDX's comparatively low scatter fraction (5.5%-8.1% measured, including off-focus radiation), high detector detective quantum efficiency (66%-73%, measured from 70 to 120 kVp), and large entrance field area (1.7x-2.3x, for the same object-plane field width). With improvements to the system geometry, detector, and x-ray source, SBDX technology is projected to achieve conventional cine-quality SNR over a full range of patient thicknesses, with 5-10 times lower skin dose

  9. Entirely saturated unilateral smear of laser spot in CCD

    International Nuclear Information System (INIS)

    Zhang Zhen; Zhou Menglian; Zhang Jianmin; Lin Xinwei

    2013-01-01

    In the video of linear CCD camera being irradiated by 532 nm CW laser, the entirely saturated unilateral smear of laser spot was found. The smear area does not represent the distribution of laser. Since this smear lies merely in one side of laser spot, it can not be induced by light leaking or carriers blooming, and it may be induced by charge transfer loss. However, the feature that the smear area is entirely saturated can not be explained by the current constant model of charge transfer inefficiency. Based on the inner structure and operating principle of buried channel CCD, a new model of charge transfer inefficiency that varies with charge quantity is proposed, which can explain the entirely saturated unilateral smear of laser spot. (authors)

  10. CCD developed for scientific application by Hamamatsu

    CERN Document Server

    Miyaguchi, K; Dezaki, J; Yamamoto, K

    1999-01-01

    We have developed CCDs for scientific applications that feature a low readout noise of less than 5 e-rms and low dark current of 10-25 pA/cm sup 2 at room temperature. CCDs with these characteristics will prove extremely useful in applications such as spectroscopic measurement and dental radiography. In addition, a large-area CCD of 2kx4k pixels and 15 mu m square pixel size has recently been completed for optical use in astronomical observations. Applications to X-ray astronomy require the most challenging device performance in terms of deep depletion, high CTE, and focal plane size, among others. An abuttable X-ray CCD, having 1024x1024 pixels and 24 mu m square pixel size, is to be installed in an international space station (ISS). We are now striving to achieve the lowest usable cooling temperature by means of a built-in TEC with limited power consumption. Details on the development status are described in this report. We would also like to present our future plans for a large active area and deep depleti...

  11. High performance CCD camera system for digitalisation of 2D DIGE gels.

    Science.gov (United States)

    Strijkstra, Annemieke; Trautwein, Kathleen; Roesler, Stefan; Feenders, Christoph; Danzer, Daniel; Riemenschneider, Udo; Blasius, Bernd; Rabus, Ralf

    2016-07-01

    An essential step in 2D DIGE-based analysis of differential proteome profiles is the accurate and sensitive digitalisation of 2D DIGE gels. The performance progress of commercially available charge-coupled device (CCD) camera-based systems combined with light emitting diodes (LED) opens up a new possibility for this type of digitalisation. Here, we assessed the performance of a CCD camera system (Intas Advanced 2D Imager) as alternative to a traditionally employed, high-end laser scanner system (Typhoon 9400) for digitalisation of differential protein profiles from three different environmental bacteria. Overall, the performance of the CCD camera system was comparable to the laser scanner, as evident from very similar protein abundance changes (irrespective of spot position and volume), as well as from linear range and limit of detection. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Technical challenges and recent progress in CCD imagers

    International Nuclear Information System (INIS)

    Bosiers, Jan T.; Peters, Inge M.; Draijer, Cees; Theuwissen, Albert

    2006-01-01

    This paper gives a review of the performance of charge-coupled device (CCD) imagers for use in consumer, professional and scientific applications. An overview of recent developments and the current state-of-the-art are presented. An extensive list of references is included

  13. Digital mammography with high-resolution storage plates (CR) versus full-field digital mammography (CCD) (DR) for microcalcifications and focal lesions - a retrospective clinical histologic analysis (n = 102)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Lell, M.; Wenkel, E.; Boehner, C.; Dassel, M.S.; Bautz, W.

    2005-01-01

    Purpose: to determine the diagnostic accuracy of microcalcifications and focal lesions in a retrospective clinical-histological study using high-resolution digital phosphor storage plates (hard copy) and full-field digital mammography (hard copy). Materials and methods: from May 2003 to September 2003, 102 patients underwent digital storage plate mammography (CR), using a mammography unit (Mammomat 3000 N, Siemens) in combination with a high resolution (9 lp/mm) digital storage phosphor plate system (pixel size 50 μm) (Fuji/Siemens). After diagnosis and preoperative wire localization, full-field digital mammography (CCD) (DR) was performed with the same exposure parameters. The full-field digital mammography used a CCD-detector (SenoScan) (fisher imaging) with a resolution of 10 Ip/mm and a pixel size of 50 μm. Five investigators determined the diagnosis (BI-RADS trademark I-V) retrospectively after the operation from randomly distributed mediolateral views (hard copy reading). These results were correlated with the final histology. Results: the diagnostic accuracy of digital storage plate mammography (CR) and full-field digital mammography (CCD) (DR) was 73% and 71% for all findings (n = 102), 73% and 71% for microcalcifications (n = 51), and 72% and 70% for focal lesions (n = 51). The overall results showed no difference. Conclusion: our findings indicate the equivalence of high-resolution digital phosphor storage plate mammography (CR) and full-field digital mammography (CCD) (DR). (orig.)

  14. CCD [charge-coupled device] sensors in synchrotron x-ray detectors

    International Nuclear Information System (INIS)

    Strauss, M.G.; Naday, I.; Sherman, I.S.; Kraimer, M.R.; Westbrook, E.M.; Zaluzec, N.J.

    1987-01-01

    The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron x-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction patterns of 100 cm 2 can be imaged on a 2 cm 2 CCD. With a conversion efficiency of ∼1 CCD electron/x-ray photon, a peak saturation capacity of >10 6 x rays can be obtained. A programmable CCD controller operating at a clock frequency of 20 MHz has been developed. The readout rate is 5 x 10 6 pixels/s and the shift rate in the parallel registers is 10 6 lines/s. The test detector was evaluated in two experiments. In protein crystallography diffraction patterns have been obtained from a lysozyme crystal using a conventional rotating anode x-ray generator. Based on these results we expect to obtain at a synchrotron diffraction images at the rate of ∼1 frame/s or a complete 3-dimensional data set from a single crystal in ∼2 min. 16 refs., 16 figs., 2 tabs

  15. High-performance visible/UV CCD focal plane technology for spacebased applications

    Science.gov (United States)

    Burke, B. E.; Mountain, R. W.; Gregory, J. A.; Huang, J. C. M.; Cooper, M. J.; Savoye, E. D.; Kosicki, B. B.

    1993-01-01

    We describe recent technology developments aimed at large CCD imagers for space based applications in the visible and UV. Some of the principal areas of effort include work on reducing device degradation in the natural space-radiation environment, improvements in quantum efficiency in the visible and UV, and larger-device formats. One of the most serious hazards for space based CCD's operating at low signal levels is the displacement damage resulting from bombardment by energetic protons. Such damage degrades charge-transfer efficiency and increases dark current. We have achieved improved hardness to proton-induced displacement damage by selective ion implants into the CCD channel and by reduced temperature of operation. To attain high quantum efficiency across the visible and UV we have developed a technology for back-illuminated CCD's. With suitable antireflection (AR) coatings such devices have quantum efficiencies near 90 percent in the 500-700-nm band. In the UV band from 200 to 400 nm, where it is difficult to find coatings that are sufficiently transparent and can provide good matching to the high refractive index of silicon, we have been able to substantially increase the quantum efficiency using a thin film of HfO2 as an AR coating. These technology efforts were applied to a 420 x 420-pixel frame-transfer imager, and future work will be extended to a 1024 x 1024-pixel device now under development.

  16. Intensified CCD for ultrafast diagnostics

    International Nuclear Information System (INIS)

    Cheng, J.; Tripp, G.; Coleman, L.

    1978-01-01

    Many of the present laser fusion diagnostics are recorded on either ultrafast streak cameras or on oscilloscopes. For those experiments in which a large volume of data is accumulated, direct computer processing of the information becomes important. We describe an approach which uses a RCA 52501 back-thinned CCD sensor to obtain direct electron readouts for both the streak camera and the CRT. Performance of the 100 GHz streak camera and the 4 GHz CRT are presented. Design parameters and computer interfacing for both systems are described in detail

  17. Design and implementation of fast bipolar clock drivers for CCD imaging systems in space applications

    Science.gov (United States)

    Jayarajan, Jayesh; Kumar, Nishant; Verma, Amarnath; Thaker, Ramkrishna

    2016-05-01

    Drive electronics for generating fast, bipolar clocks, which can drive capacitive loads of the order of 5-10nF are indispensable for present day Charge Coupled Devices (CCDs). Design of these high speed bipolar clocks is challenging because of the capacitive loads that have to be driven and a strict constraint on the rise and fall times. Designing drive electronics circuits for space applications becomes even more challenging due to limited number of available discrete devices, which can survive in the harsh radiation prone space environment. This paper presents the design, simulations and test results of a set of such high speed, bipolar clock drivers. The design has been tested under a thermal cycle of -15 deg C to +55 deg C under vacuum conditions and has been designed using radiation hardened components. The test results show that the design meets the stringent rise/fall time requirements of 50+/-10ns for Multiple Vertical CCD (VCCD) clocks and 20+/-5ns for Horizontal CCD (HCCD) clocks with sufficient design margins across full temperature range, with a pixel readout rate of 6.6MHz. The full design has been realized in flexi-rigid PCB with package volume of 140x160x50 mm3.

  18. Measurement of phase function of aerosol at different altitudes by CCD Lidar

    Science.gov (United States)

    Sun, Peiyu; Yuan, Ke'e.; Yang, Jie; Hu, Shunxing

    2018-02-01

    The aerosols near the ground are closely related to human health and climate change, the study on which has important significance. As we all know, the aerosol is inhomogeneous at different altitudes, of which the phase function is also different. In order to simplify the retrieval algorithm, it is usually assumed that the aerosol is uniform at different altitudes, which will bring measurement error. In this work, an experimental approach is demonstrated to measure the scattering phase function of atmospheric aerosol particles at different heights by CCD lidar system, which could solve the problem of the traditional CCD lidar system in assumption of phase function. The phase functions obtained by the new experimental approach are used to retrieve the aerosol extinction coefficient profiles. By comparison of the aerosol extinction coefficient retrieved by Mie-scattering aerosol lidar and CCD lidar at night, the reliability of new experimental approach is verified.

  19. Design principles and applications of a cooled CCD camera for electron microscopy.

    Science.gov (United States)

    Faruqi, A R

    1998-01-01

    Cooled CCD cameras offer a number of advantages in recording electron microscope images with CCDs rather than film which include: immediate availability of the image in a digital format suitable for further computer processing, high dynamic range, excellent linearity and a high detective quantum efficiency for recording electrons. In one important respect however, film has superior properties: the spatial resolution of CCD detectors tested so far (in terms of point spread function or modulation transfer function) are inferior to film and a great deal of our effort has been spent in designing detectors with improved spatial resolution. Various instrumental contributions to spatial resolution have been analysed and in this paper we discuss the contribution of the phosphor-fibre optics system in this measurement. We have evaluated the performance of a number of detector components and parameters, e.g. different phosphors (and a scintillator), optical coupling with lens or fibre optics with various demagnification factors, to improve the detector performance. The camera described in this paper, which is based on this analysis, uses a tapered fibre optics coupling between the phosphor and the CCD and is installed on a Philips CM12 electron microscope equipped to perform cryo-microscopy. The main use of the camera so far has been in recording electron diffraction patterns from two dimensional crystals of bacteriorhodopsin--from wild type and from different trapped states during the photocycle. As one example of the type of data obtained with the CCD camera a two dimensional Fourier projection map from the trapped O-state is also included. With faster computers, it will soon be possible to undertake this type of work on an on-line basis. Also, with improvements in detector size and resolution, CCD detectors, already ideal for diffraction, will be able to compete with film in the recording of high resolution images.

  20. Occupation, exposure to chemicals, sensitizing agents, and risk of multiple myeloma in Sweden.

    Science.gov (United States)

    Lope, Virginia; Pérez-Gómez, Beatriz; Aragonés, Nuria; López-Abente, Gonzalo; Gustavsson, Per; Plato, Nils; Zock, Jan-Paul; Pollán, Marina

    2008-11-01

    This study sought to identify occupations with high incidence of multiple myeloma and to investigate possible excess risk associated with occupational exposure to chemicals and sensitizing agents in Sweden. A historical cohort of 2,992,166 workers was followed up (1971--1989) through record linkage with the National Cancer and Death Registries. For each job category, age and period standardized incidence ratios and age and period adjusted relative risks of multiple myeloma were calculated using Poisson models. Exposure to chemicals and to sensitizing agents was also assessed using two job-exposure matrices. Men and women were analyzed separately. During follow-up, 3,127 and 1,282 myelomas were diagnosed in men and women, respectively. In men, excess risk was detected among working proprietors, agricultural, horticultural and forestry enterprisers, bakers and pastry cooks, dental technicians, stone cutters/carvers, and prison/reformatory officials. In women, this excess was observed among attendants in psychiatric care, metal workers, bakers and pastry cooks, and paper/paperboard product workers. Workers, particularly bakers and pastry cooks, exposed to high molecular weight sensitizing agents registered an excess risk of over 40% across the sexes. Occasional, although intense, exposure to pesticides was also associated with risk of myeloma in our cohort. Our study supports a possible etiologic role for farming and use of pesticides in myeloma risk. The high incidence found in both female and male bakers and pastry cooks has not been described previously. Further research is required to assess the influence of high molecular weight sensitizing agents on risk of multiple myeloma.

  1. Real-time tricolor phase measuring profilometry based on CCD sensitivity calibration

    Science.gov (United States)

    Zhu, Lin; Cao, Yiping; He, Dawu; Chen, Cheng

    2017-02-01

    A real-time tricolor phase measuring profilometry (RTPMP) based on charge coupled device (CCD) sensitivity calibration is proposed. Only one colour fringe pattern whose red (R), green (G) and blue (B) components are, respectively, coded as three sinusoidal phase-shifting gratings with an equivalent shifting phase of 2π/3 is needed and sent to an appointed flash memory on a specialized digital light projector (SDLP). A specialized time-division multiplexing timing sequence actively controls the SDLP to project the fringe patterns in R, G and B channels sequentially onto the measured object in one over seventy-two of a second and meanwhile actively controls a high frame rate monochrome CCD camera to capture the corresponding deformed patterns synchronously with the SDLP. So the sufficient information for reconstructing the three-dimensional (3D) shape in one over twenty-four of a second is obtained. Due to the different spectral sensitivity of the CCD camera to RGB lights, the captured deformed patterns from R, G and B channels cannot share the same peak and valley, which will lead to lower accuracy or even failing to reconstruct the 3D shape. So a deformed pattern amending method based on CCD sensitivity calibration is developed to guarantee the accurate 3D reconstruction. The experimental results verify the feasibility of the proposed RTPMP method. The proposed RTPMP method can obtain the 3D shape at over the video frame rate of 24 frames per second, avoid the colour crosstalk completely and be effective for measuring real-time changing object.

  2. Development of online cable eccentricity detection system based on X-ray CCD

    International Nuclear Information System (INIS)

    Chen Jianzhen; Li Bin; Wei Kaixia; Guo Lanying; Qu Guopu

    2008-01-01

    An improved technology of online cable eccentricity detection, based on X-ray CCD, greatly improves the measuring precision and the responding speed. The theory of eccentricity measuring based on X-ray CCD, and the structure of an apparatus are described. The apparatus is composed of scanning drive subsystem, X-ray generation components, data acquiring subsystem and high performance computer system. The measuring results are also presented. The features of this cable eccentricity detection technology are compared with the features of other technologies. (authors)

  3. Development of a Portable 3CCD Camera System for Multispectral Imaging of Biological Samples

    Science.gov (United States)

    Lee, Hoyoung; Park, Soo Hyun; Noh, Sang Ha; Lim, Jongguk; Kim, Moon S.

    2014-01-01

    Recent studies have suggested the need for imaging devices capable of multispectral imaging beyond the visible region, to allow for quality and safety evaluations of agricultural commodities. Conventional multispectral imaging devices lack flexibility in spectral waveband selectivity for such applications. In this paper, a recently developed portable 3CCD camera with significant improvements over existing imaging devices is presented. A beam-splitter prism assembly for 3CCD was designed to accommodate three interference filters that can be easily changed for application-specific multispectral waveband selection in the 400 to 1000 nm region. We also designed and integrated electronic components on printed circuit boards with firmware programming, enabling parallel processing, synchronization, and independent control of the three CCD sensors, to ensure the transfer of data without significant delay or data loss due to buffering. The system can stream 30 frames (3-waveband images in each frame) per second. The potential utility of the 3CCD camera system was demonstrated in the laboratory for detecting defect spots on apples. PMID:25350510

  4. The OCA CCD Camera Controller

    Science.gov (United States)

    1996-01-01

    multi CCD arrays for wide field telescopes with an array of 8x8 1K CCDs in use at Las Campanas Observatory in Chile . The same group is also involved...Verify key EPROM -292H VIH . VIH Program security bitl 1 29AH . VPP Program security’ bit 2 *. .298H -Vpp Verify security bits - 9HVIH ViI NOTE: 1...Pulsed from V.. to VIL and returned to VIH . EPROM PROGRAMMING AND VERIFICATION ..t= 21’C to-+27 ’rC:-VCC= 5V ±10%VS3 = OV. SYMBOL I .-- PARAMETER MIN MAX

  5. Two-dimensional spectrophotometry of planetary nebulae by CCD imaging

    International Nuclear Information System (INIS)

    Jacoby, G.H.; Africano, J.L.; Quigley, R.J.; Western Washington Univ., Bellingham, WA)

    1987-01-01

    The spatial distribution of the electron temperature and density and the ionic abundances of O(+), O(2+), N(+), and S(+) have been derived from CCD images of the planetary nebulae NGC 40 and NGC 6826 taken in the important emission lines of forbidden O II, forbidden O III, H-beta, forbidden N II, and forbidden S II. The steps required in the derivation of the absolute fluxes, line, ratios, and ionic abundances are outlined and then discussed in greater detail. The results show that the CCD imaging technique for two-dimensional spectrophotometry can effectively compete with classical spectrophotometry, providing the added benefits of complete spatial coverage at seeing-disk spatial resolution. The multiplexing in the spatial dimension, however, results in a loss of spectral information, since only one emission line is observed at any one time. 37 references

  6. Prenatal cigarette smoke exposure and early initiation of multiple substance use.

    Science.gov (United States)

    Goldschmidt, Lidush; Cornelius, Marie D; Day, Nancy L

    2012-06-01

    Earlier studies have shown a relation between prenatal cigarette smoke exposure (PCSE) and offspring initiation of tobacco use. No prior study has examined the association between PCSE and early initiation of multiple substances (EIMS) including marijuana and alcohol in addition to tobacco. We investigated the association between PCSE and multiple substance use during adolescence. Pregnant women attending an urban prenatal clinic were selected to participate in the prospective longitudinal study based on their substance use. This study is based on the 16-year follow-up phase and consists of 579 mother-offspring dyads. The women were of lower socioeconomic status, 54% were Black, and 53% reported smoking cigarettes. 52% of the offspring were female. EIMS is a measure of the number of substances initiated prior to age 16 by the adolescents; it ranged from 0 (no initiation, N = 166) to 3 (all, N = 162). Adolescents exposed to tobacco during first trimester of gestation were 1.4 times more likely to initiate multiple substances by age 16 than the nonexposed group. PCSE was a significant predictor of EIMS after controlling for other prenatal exposures, home environment, and demographic characteristics, using ordinal polytomous logistic regression. Other risk factors of EIMS were maternal and adolescent depression, less strict and less involved parenting, offspring attention problems, and lack of participation in a youth club. There is a significant relation between PCSE and adolescent's EIMS.

  7. Sunlight exposure and sun sensitivity associated with disability progression in multiple sclerosis

    NARCIS (Netherlands)

    D'hooghe, M. B.; Haentjens, P.; Nagels, G.; Garmyn, M.; De Keyser, J.

    Background: Sunlight and vitamin D have been inversely associated with the risk of multiple sclerosis (MS). Objective: We investigated sunlight exposure and sun sensitivity in relation to disability progression in MS. Methods: We conducted a survey among persons with MS, registered by the Flemish MS

  8. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Takeshita, E., E-mail: eriuli@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Furukawa, T., E-mail: t_furu@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Inaniwa, T., E-mail: taku@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Sato, S., E-mail: shin_s@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Himukai, T., E-mail: himukai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Shirai, T., E-mail: t_shirai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Noda, K., E-mail: noda_k@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan)

    2011-12-15

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  9. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Science.gov (United States)

    Takeshita, E.; Furukawa, T.; Inaniwa, T.; Sato, S.; Himukai, T.; Shirai, T.; Noda, K.

    2011-12-01

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  10. Surimpressions naturelles et volontaires chez les surréalistes. Un regard multiple sur Paris Voluntary and natural multiple exposure among Surrealists. A manifold view on Paris

    Directory of Open Access Journals (Sweden)

    Héloïse Pocry

    2009-10-01

    Full Text Available La surimpression photographique, simple accident technique consistant à impressionner plusieurs fois une même surface sensible, fut mise à profit par les avant-gardes photographiques des années 1920 et 1930 pour révéler les aspects insolites ou poétiques du paysage urbain et traduire les sensations démultipliées dans cet environnement. Les reflets dans les vitrines sont également pourvoyeurs de superpositions visuelles dans la ville. Les avant-gardes vont s’intéresser à ce phénomène comme une surimpression à l’état naturel, en particulier les surréalistes, portés par leur goût du hasard et de la déambulation urbaine. Surimpressions volontaires et naturelles sont deux procédés permettant de rendre compte de l’expérience multiple du passant dans le paysage urbain. La surimpression est-elle la transposition photographique de l’expérience des reflets de vitrine ? Dans quelle mesure ces deux procédés réussissent-ils à reproduire efficacement les perturbations sensitives qui peuvent assaillir le passant dans le paysage urbain ? Nous mettrons en évidence à travers un corpus de textes et de photographies principalement issu du surréalisme des années 1920 et 1930 les enjeux des surimpressions naturelles et volontaires. Nous étudierons comment elles ont été utilisées par les surréalistes parisiens pour conduire le spectateur vers une perception et une compréhension nouvelles du paysage urbain de la capitale française.Photographic multiple exposure, a simple technical accident consisting in exposing several times the same sensitized material, was capitalized on by the photographic avant-garde in the 1920s and 1930s. Their aim was to reveal unusual or poetic aspects within urban landscape and convey its multiple sensations. Reflections on windows also provide visual urban superpositions. Avant-gardists conceived of this phenomenon as a natural multiple exposure. Surrealists were particularly fond of this

  11. Chemosensory perception, symptoms and autonomic responses during chemical exposure in multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Andersson, Linus; Claeson, Anna Sara; Dantoft, Thomas Meinertz

    2016-01-01

    Purpose: Multiple chemical sensitivity (MCS) is a prevalent medically unexplained symptom characterized by symptom reactions to everyday chemical exposure below hygienic thresholds. The aim of this study was to investigate the expressions of hyper-reactivity in MCS during whole-body exposure to low...... concentrations of the odorant n-butanol. Methods: We exposed 18 participants with MCS and 18 non-ill controls to a low concentration of the odorant n-butanol using an exposure chamber. The first 10 min constituted blank exposure, after which the n-butanol concentration increased and reached a plateau at 11.5 mg....../m3. Results: MCS participants, compared with controls, reported greater perceived odor intensities, more unpleasantness to the exposure and increasing symptoms over time. MCS participants also expressed higher pulse rate and lower pulse rate variability than controls did. No group differences were...

  12. New low noise CCD cameras for Pi-of-the-Sky project

    Science.gov (United States)

    Kasprowicz, G.; Czyrkowski, H.; Dabrowski, R.; Dominik, W.; Mankiewicz, L.; Pozniak, K.; Romaniuk, R.; Sitek, P.; Sokolowski, M.; Sulej, R.; Uzycki, J.; Wrochna, G.

    2006-10-01

    Modern research trends require observation of fainter and fainter astronomical objects on large areas of the sky. This implies usage of systems with high temporal and optical resolution with computer based data acquisition and processing. Therefore Charge Coupled Devices (CCD) became so popular. They offer quick picture conversion with much better quality than film based technologies. This work is theoretical and practical study of the CCD based picture acquisition system. The system was optimized for "Pi of The Sky" project. But it can be adapted to another professional astronomical researches. The work includes issue of picture conversion, signal acquisition, data transfer and mechanical construction of the device.

  13. Numerical simulations and analyses of temperature control loop heat pipe for space CCD camera

    Science.gov (United States)

    Meng, Qingliang; Yang, Tao; Li, Chunlin

    2016-10-01

    As one of the key units of space CCD camera, the temperature range and stability of CCD components affect the image's indexes. Reasonable thermal design and robust thermal control devices are needed. One kind of temperature control loop heat pipe (TCLHP) is designed, which highly meets the thermal control requirements of CCD components. In order to study the dynamic behaviors of heat and mass transfer of TCLHP, particularly in the orbital flight case, a transient numerical model is developed by using the well-established empirical correlations for flow models within three dimensional thermal modeling. The temperature control principle and details of mathematical model are presented. The model is used to study operating state, flow and heat characteristics based upon the analyses of variations of temperature, pressure and quality under different operating modes and external heat flux variations. The results indicate that TCLHP can satisfy the thermal control requirements of CCD components well, and always ensure good temperature stability and uniformity. By comparison between flight data and simulated results, it is found that the model is to be accurate to within 1°C. The model can be better used for predicting and understanding the transient performance of TCLHP.

  14. Design and realization of an AEC&AGC system for the CCD aerial camera

    Science.gov (United States)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  15. CCD photometry of apparent dwarf galaxies in Fornax

    International Nuclear Information System (INIS)

    Phillipps, S.; Grimley, P.L.; Disney, M.J.; Cawson, M.G.M.; Kibblewhite, E.J.

    1986-01-01

    Blue and red CCD surface photometry of two apparent dwarf galaxies in the Fornax cluster region is presented. Luminosity profiles are derived and their form discussed. The fainter galaxy resembles an archetypal diffuse dwarf elliptical but the brighter of the pair is either an unusual red dwarf or a background galaxy in chance juxtaposition. (author)

  16. The development of high-speed 100 fps CCD camera

    International Nuclear Information System (INIS)

    Hoffberg, M.; Laird, R.; Lenkzsus, F.; Liu, C.; Rodricks, B.

    1997-01-01

    This paper describes the development of a high-speed CCD digital camera system. The system has been designed to use CCDs from various manufacturers with minimal modifications. The first camera built on this design utilizes a Thomson 512 x 512 pixel CCD as its sensor, which is read out from two parallel outputs at a speed of 15 MHz/pixel/output. The data undergo correlated double sampling after which it is digitized into 12 bits. The throughput of the system translates into 60 MB/second, which is either stored directly in a PC or transferred to a custom-designed VXI module. The PC data acquisition version of the camera can collect sustained data in real time that is limited to the memory installed in the PC. The VXI version of the camera, also controlled by a PC, stores 512 MB of real-time data before it must be read out to the PC disk storage. The uncooled CCD can be used either with lenses for visible light imaging or with a phosphor screen for X-ray imaging. This camera has been tested with a phosphor screen coupled to a fiber-optic face plate for high-resolution, high-speed X-ray imaging. The camera is controlled through a custom event-driven user-friendly Windows package. The pixel clock speed can be changed from 1 to 15 MHz. The noise was measured to be 1.05 bits at a 13.3 MHz pixel clock. This paper will describe the electronics, software, and characterizations that have been performed using both visible and X-ray photons. (orig.)

  17. Application of the CCD Fabry-Perot Annular Summing Technique to Thermospheric O(1)D.

    Science.gov (United States)

    Coakley, Monica Marie

    1995-01-01

    This work will detail the verification of the advantages of the Fabry-Perot charge coupled device (CCD) annular summing technique, the development of the technique for analysis of daysky spectra, and the implications of the resulting spectra for neutral temperature and wind measurements in the daysky thermosphere. The daysky spectral feature of interest is the bright (1 kilo-Rayleigh) thermospheric (OI) emission at 6300 A which had been observed in the nightsky in order to determine winds and temperatures in the vicinity of the altitude of 250 km. In the daysky, the emission line sits on top of a bright Rayleigh scattered continuum background which significantly complicates the observation. With a triple etalon Fabry-Perot spectrometer, the continuum background can be reduced while maintaining high throughput and high resolution. The inclusion of a CCD camera results in significant savings in integration time over the two more standard scanning photomultiplier systems that have made the same wind and temperature measurements in the past. A comparable CCD system can experience an order of magnitude savings in integration time over a PMT system. Laboratory and field tests which address the advantages and limitations of both the Fabry-Perot CCD annular summing technique and the daysky CCD imaging are included in Chap. 2 and Chap. 3. With a sufficiently large throughput associated with the spectrometer and a CCD detector, rapid observations (~4 minute integrations) can be made. Extraction of the line width and line center from the daysky near-continuum background is complicated compared to the nightsky case, but possible. Methods of fitting the line are included in Chap. 4. The daysky O ^1D temperatures are consistent with a lower average emission height than predicted by models. The data and models are discussed in Chap. 5. Although some discrepancies exist between resulting temperatures and models, the observations indicate the potential for other direct measurements

  18. Cumulative health risk assessment: integrated approaches for multiple contaminants, exposures, and effects

    International Nuclear Information System (INIS)

    Rice, Glenn; Teuschler, Linda; MacDonel, Margaret; Butler, Jim; Finster, Molly; Hertzberg, Rick; Harou, Lynne

    2007-01-01

    Available in abstract form only. Full text of publication follows: As information about environmental contamination has increased in recent years, so has public interest in the combined effects of multiple contaminants. This interest has been highlighted by recent tragedies such as the World Trade Center disaster and hurricane Katrina. In fact, assessing multiple contaminants, exposures, and effects has long been an issue for contaminated sites, including U.S. Department of Energy (DOE) legacy waste sites. Local citizens have explicitly asked the federal government to account for cumulative risks, with contaminants moving offsite via groundwater flow, surface runoff, and air dispersal being a common emphasis. Multiple exposures range from ingestion and inhalation to dermal absorption and external gamma irradiation. Three types of concerns can lead to cumulative assessments: (1) specific sources or releases - e.g., industrial facilities or accidental discharges; (2) contaminant levels - in environmental media or human tissues; and (3) elevated rates of disease - e.g., asthma or cancer. The specific initiator frames the assessment strategy, including a determination of appropriate models to be used. Approaches are being developed to better integrate a variety of data, extending from environmental to internal co-location of contaminants and combined effects, to support more practical assessments of cumulative health risks. (authors)

  19. Flatfielding Errors in Strömvil CCD Photometry

    Directory of Open Access Journals (Sweden)

    Boyle R. P.

    2003-12-01

    Full Text Available The importance of determining the error of the flat field in CCD photometry is detailed and our methods of doing this are described. We now have reached a precision of 1-1.5 % in our photometry. Color-magnitude diagrams of the open cluster M67 (ours and Laugalys et al. 2003 are compared.

  20. Exposure to electromagnetic fields aboard high-speed electric multiple unit trains.

    Science.gov (United States)

    Niu, D; Zhu, F; Qiu, R; Niu, Q

    2016-01-01

    High-speed electric multiple unit (EMU) trains generate high-frequency electric fields, low-frequency magnetic fields, and high-frequency wideband electromagnetic emissions when running. Potential human health concerns arise because the electromagnetic disturbances are transmitted mainly into the car body from windows, and from there to passengers and train staff. The transmission amount and amplitude distribution characteristics that dominate electromagnetic field emission need to be studied, and the exposure level of electromagnetic field emission to humans should be measured. We conducted a series of tests of the on board electromagnetic field distribution on several high-speed railway lines. While results showed that exposure was within permitted levels, the possibility of long-term health effects should be investigated.

  1. A FORTRAN version implementation of block adjustment of CCD frames and its preliminary application

    Science.gov (United States)

    Yu, Y.; Tang, Z.-H.; Li, J.-L.; Zhao, M.

    2005-09-01

    A FORTRAN version implementation of the block adjustment (BA) of overlapping CCD frames is developed and its flowchart is shown. The program is preliminarily applied to obtain the optical positions of four extragalactic radio sources. The results show that because of the increase in the number and sky coverage of reference stars the precision of optical positions with BA is improved compared with the single CCD frame adjustment.

  2. BVR Standardization of the CCD Photometric System of Chungbuk National University Observatory

    Directory of Open Access Journals (Sweden)

    Jang-Hae Jeong

    2009-06-01

    Full Text Available BVR observations for 52 standard stars were performed using the 1-m reflecter with 2K CCD System of Chungbuk National University Observatory(CBNUO in 2008. We obtained 1,322 CCD images to establish a correlation between our bvr system and the standard Johnson-Cousins BVR system. We derived the tentative equations of transformation between then as follows; V = v-0.0303(B-V+0.0466 B-V = 1.3475(b-v-0.0251 V-R = 1.0641(v-r-0.0125 Using these equations the magnitudes in V, B-V, and V-R for 197 stars were obtained.

  3. Sun exposure over the life course and associations with multiple sclerosis.

    Science.gov (United States)

    Tremlett, Helen; Zhu, Feng; Ascherio, Alberto; Munger, Kassandra L

    2018-04-03

    To examine sun exposure and multiple sclerosis (MS) over the life course (ages 5-15 and 16-20 years, every 10 years thereafter). Cases with MS (n = 151) and age-matched controls (n = 235) from the Nurses' Health Study cohorts completed summer, winter, and lifetime sun exposure history questionnaires. Cumulative ambient ultraviolet (UV)-B (based on latitude, altitude, cloud cover) exposure before MS onset was expressed as tertiles. Seasonal sun exposure was defined as low vs high hours per week (summer [≤9 vs >10 h/wk]; winter [≤3 vs >4 h/wk]). Relative risks (RRs) and 95% confidence intervals (CIs) were estimated via conditional logistic regression with adjustment for body mass index, ancestry, smoking, and vitamin D supplementation. Most participants were white (98%); the mean age at MS onset was 39.5 years. Living in high (vs low) UV-B areas before MS onset was associated with a 45% lower MS risk (adjusted RR 0.55, 95% CI 0.42-0.73). Similar reduced risks (51%-52%) for medium or high exposure were observed at ages 5 to 15 years and at 5 to 15 years before MS onset (adjusted p sun exposure were associated with a lower MS risk (RR 0.45, 95% CI 0.21-0.96). Living in high ambient UV-B areas during childhood and the years leading up to MS onset was associated with a lower MS risk. High summer sun exposure in high ambient UV-B areas was also associated with a reduced risk. © 2018 American Academy of Neurology.

  4. Accounting for multiple climate components when estimating climate change exposure and velocity

    Science.gov (United States)

    Nadeau, Christopher P.; Fuller, Angela K.

    2015-01-01

    The effect of anthropogenic climate change on organisms will likely be related to climate change exposure and velocity at local and regional scales. However, common methods to estimate climate change exposure and velocity ignore important components of climate that are known to affect the ecology and evolution of organisms.We develop a novel index of climate change (climate overlap) that simultaneously estimates changes in the means, variation and correlation between multiple weather variables. Specifically, we estimate the overlap between multivariate normal probability distributions representing historical and current or projected future climates. We provide methods for estimating the statistical significance of climate overlap values and methods to estimate velocity using climate overlap.We show that climates have changed significantly across 80% of the continental United States in the last 32 years and that much of this change is due to changes in the variation and correlation between weather variables (two statistics that are rarely incorporated into climate change studies). We also show that projected future temperatures are predicted to be locally novel (using climate overlap compared to 1·4 km yr−1 when estimated using traditional methods.Our results suggest that accounting for changes in the means, variation and correlation between multiple weather variables can dramatically affect estimates of climate change exposure and velocity. These climate components are known to affect the ecology and evolution of organisms, but are ignored by most measures of climate change. We conclude with a set of future directions and recommend future work to determine which measures of climate change exposure and velocity are most related to biological responses to climate change.

  5. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  6. Alpha-risk: a European project on the quantification of risks associated with multiple radiation exposures

    International Nuclear Information System (INIS)

    Laurier, D.; Monchaux, G.; Tirmarche, M.; Darby, S.; Cardis, E.; Binks, K.; Hofmann, W.; Muirhead, C.

    2006-01-01

    The Alpha-Risk research project is being conducted within the Sixth European Framework Programme (EC-FP6, 2005 -2008). It aims to improve the quantification of risks associated with multiple exposures, taking into account the contribution of different radionuclides and external exposure using specific organ dose calculations. The Alpha-Risk Consortium involves 18 partners from 9 countries, and is coordinated by the IRSN. Its composition allows a multidisciplinary collaboration between researchers in epidemiology, dosimetry, statistics, modelling and risk assessment. Alpha-Risk brings together major epidemiological studies in Europe, which are able to evaluate long-term health effects of internal exposure from radionuclides. It includes large size cohort and case-control studies, with accurate registration of individual annual exposures: uranium miner studies, studies on lung cancer and indoor radon exposure, and studies of lung cancer and leukaemia among nuclear workers exposed to transuranic nuclides (mainly uranium and plutonium), for whom organ doses will be reconstructed individually. The contribution of experts in dosimetry will allow the calculation of organ doses in presence of multiple exposures (radon decay products, uranium dust and external gamma exposure). Expression of the risk per unit organ dose will make it possible to compare results with those from other populations exposed to external radiation. The multidisciplinary approach of Alpha-Risk promotes the development of coherent and improved methodological approaches regarding risk modelling. A specific work - package is dedicated to the integration of results and their use for risk assessment, especially for radon. Alpha-Risk will contribute to a better understanding of long-term health risks following chronic low doses from internal exposures. The project also has the great potential to help resolve major public health concerns about the effects of low and/or protracted exposures, especially

  7. 77 FR 42713 - Notice of Proposed Information Collection RequestsNPEFS 2011-2014: Common Core of Data (CCD...

    Science.gov (United States)

    2012-07-20

    ... Core of Data (CCD) National Public Education Financial Survey AGENCY: Institute of Education Sciences, Department of Education. SUMMARY: The National Public Education Financial Survey (NPEFS) is an annual... of Data (CCD) National Public Education Financial Survey. OMB Control Number: 1850-0067. [[Page 42714...

  8. Noise in off-axis type holograms including reconstruction and CCD camera parameters

    Energy Technology Data Exchange (ETDEWEB)

    Voelkl, Edgar, E-mail: edgar.voelkl@fei.com [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124-5793 (United States)

    2010-02-15

    Phase and amplitude images as contained in digital holograms are commonly extracted via a process called 'reconstruction'. Expressions for the expected noise in these images have been given in the past by several authors; however, the effect of the actual reconstruction process has not been fully appreciated. By starting with the Quantum Mechanical intensity distribution of the off-axis type interference pattern, then building the digital hologram on an electron-by-electron base while simultaneously reconstructing the phase/amplitude images and evaluating their noise levels, an expression is derived that consistently describes the noise in simulated and experimental phase/amplitude images and contains the reconstruction parameters. Because of the necessity to discretize the intensity distribution function, the digitization effects of an ideal CCD camera had to be included. Subsequently, this allowed a comparison between real and simulated holograms which then led to a comparison between the performance of an 'ideal' CCD camera versus a real device. It was concluded that significant improvement of the phase and amplitude noise may be obtained if CCD cameras were optimized for digitizing intensity distributions at low sampling rates.

  9. Development of network based control and data acquisition systems for diagnostics using CCD detectors. Application to LHD experiments

    International Nuclear Information System (INIS)

    Kado, Shinichiro; Nakanishi, Hideya; Ida, Katsumi; Kojima, Mamoru

    2000-01-01

    The needs of CCD detectors as a plasma diagnostic tool have recently been increased. However, many CCD providers have developed their own controlling systems, and it is difficult to customized the usages in order to make them applicable to the network-based data acquisition clusters which consist of various sorts of diagnostics. This paper presents the development of systems in which CCD detectors are controlled and the data are acquired through networks. By making use of the Client/Server (C/S) model in the Windows NT operating system and block transfer method via shared memory relevant to the model, the dependence on the hardware is hidden by the server service, CCD list sequencer. The client program is designed for the LHD (Large Helical Device) discharge operation sequences and the data acquisition system. (author)

  10. New Design Concept for Universal CCD Controller

    Directory of Open Access Journals (Sweden)

    Wonyong Han

    1994-06-01

    Full Text Available Currently, the CCDs are widely used in astronomical observations either in direct imaging use or spectroscopic mode. However according to the recent technical advances, new large format CCDs are rapidly developed which have better performances with higher quantum efficiency and sensitivity. In many cases, some microprocessors have been adopted to deal with necessary digital logic for a CCD imaging system. This could often lack the flexibility of a system for a user to upgrade with new devices, especially of it is a commercial product. A new design concept has been explored which could provide the opportunity to deal with any format of devices from ant manufactures effectively for astronomical purposes. Recently available PLD (Programmable Logic Devices technology makes it possible to develop such digital circuit design, which can be integrated into a single component, instead of using microprocessors. The design concept could dramatically increase the efficiency and flexibility of a CCD imaging system, particularly when new or large format devices are available and to upgrade the performance of a system. Some variable system control parameters can be selected by a user with a wider range of choice. The software can support such functional requirements very conveniently. This approach can be applied not only to astronomical purpose, but also to some related fields, such as remote sensing and industrial applications.

  11. Phase shifting white light interferometry using colour CCD for optical metrology and bio-imaging applications

    Science.gov (United States)

    Upputuri, Paul Kumar; Pramanik, Manojit

    2018-02-01

    Phase shifting white light interferometry (PSWLI) has been widely used for optical metrology applications because of their precision, reliability, and versatility. White light interferometry using monochrome CCD makes the measurement process slow for metrology applications. WLI integrated with Red-Green-Blue (RGB) CCD camera is finding imaging applications in the fields optical metrology and bio-imaging. Wavelength dependent refractive index profiles of biological samples were computed from colour white light interferograms. In recent years, whole-filed refractive index profiles of red blood cells (RBCs), onion skin, fish cornea, etc. were measured from RGB interferograms. In this paper, we discuss the bio-imaging applications of colour CCD based white light interferometry. The approach makes the measurement faster, easier, cost-effective, and even dynamic by using single fringe analysis methods, for industrial applications.

  12. Cooling System for a Frame-Store PN-CCD Detector for Low Background Application

    CERN Document Server

    Pereira, H; Santos Silva, P; Kuster, M; Lang, P

    2012-01-01

    The astroparticle physics experiment CERN Axion Solar Telescope (CAST) aims to detect hypothetical axions or axion-like particles produced in the Sun by the Primakoff process. A Large Hadron Collider (LHC) prototype superconducting dipole magnet provides a 9 T transverse magnetic field for the conversion of axions into detectable X-ray photons. These photons are detected with an X-ray telescope and a novel type of frame-store CCD detector built from radio-pure materials, installed in the optics focal plane. A novel type of cooling system has been designed and built based on krypton-filled cryogenic heat pipes, made out of oxygen-free radiopure copper, and a Stirling cryocooler as cold source. The heat pipes provide an efficient thermal coupling between the cryocooler and the CCD which is kept at stable temperatures between 150 and 230 K within an accuracy of 0.1 K. A graded-Z radiation shield, also serving as a gas cold-trap operated at 120 K, is implemented to reduce the surface contamination of the CCD wind...

  13. Development of X-ray CCD camera system with high readout rate using ASIC

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Matsuura, Daisuke; Anabuki, Naohisa; Miyata, Emi; Tsunemi, Hiroshi; Doty, John P.; Ikeda, Hirokazu; Katayama, Haruyoshi

    2009-01-01

    We report on the development of an X-ray charge-coupled device (CCD) camera system with high readout rate using application-specific integrated circuit (ASIC) and Camera Link standard. The distinctive ΔΣ type analog-to-digital converter is introduced into the chip to achieve effective noise shaping and to obtain a high resolution with relatively simple circuits. The unit test proved moderately low equivalent input noise of 70μV with a high readout pixel rate of 625 kHz, while the entire chip consumes only 100 mW. The Camera Link standard was applied for the connectivity between the camera system and frame grabbers. In the initial test of the whole system, we adopted a P-channel CCD with a thick depletion layer developed for X-ray CCD camera onboard the next Japanese X-ray astronomical satellite. The characteristic X-rays from 109 Cd were successfully read out resulting in the energy resolution of 379(±7)eV (FWHM) at 22.1 keV, that is, ΔE/E=1.7% with a readout rate of 44 kHz.

  14. Variations in community exposure to lahar hazards from multiple volcanoes in Washington State (USA)

    Science.gov (United States)

    Diefenbach, Angela K.; Wood, Nathan J.; Ewert, John W.

    2015-01-01

    Understanding how communities are vulnerable to lahar hazards provides critical input for effective design and implementation of volcano hazard preparedness and mitigation strategies. Past vulnerability assessments have focused largely on hazards posed by a single volcano, even though communities and officials in many parts of the world must plan for and contend with hazards associated with multiple volcanoes. To better understand community vulnerability in regions with multiple volcanic threats, we characterize and compare variations in community exposure to lahar hazards associated with five active volcanoes in Washington State, USA—Mount Baker, Glacier Peak, Mount Rainier, Mount Adams and Mount St. Helens—each having the potential to generate catastrophic lahars that could strike communities tens of kilometers downstream. We use geospatial datasets that represent various population indicators (e.g., land cover, residents, employees, tourists) along with mapped lahar-hazard boundaries at each volcano to determine the distributions of populations within communities that occupy lahar-prone areas. We estimate that Washington lahar-hazard zones collectively contain 191,555 residents, 108,719 employees, 433 public venues that attract visitors, and 354 dependent-care facilities that house individuals that will need assistance to evacuate. We find that population exposure varies considerably across the State both in type (e.g., residential, tourist, employee) and distribution of people (e.g., urban to rural). We develop composite lahar-exposure indices to identify communities most at-risk and communities throughout the State who share common issues of vulnerability to lahar-hazards. We find that although lahars are a regional hazard that will impact communities in different ways there are commonalities in community exposure across multiple volcanoes. Results will aid emergency managers, local officials, and the public in educating at-risk populations and developing

  15. CCD imaging technology and the war on crime

    Science.gov (United States)

    McNeill, Glenn E.

    1992-08-01

    Linear array based CCD technology has been successfully used in the development of an Automatic Currency Reader/Comparator (ACR/C) system. The ACR/C system is designed to provide a method for tracking US currency in the organized crime and drug trafficking environments where large amounts of cash are involved in illegal transactions and money laundering activities. United States currency notes can be uniquely identified by the combination of the denomination serial number and series year. The ACR/C system processes notes at five notes per second using a custom transport a stationary linear array and optical character recognition (OCR) techniques to make such identifications. In this way large sums of money can be " marked" (using the system to read and store their identifiers) and then circulated within various crime networks. The system can later be used to read and compare confiscated notes to the known sets of identifiers from the " marked" set to document a trail of criminal activities. With the ACR/C law enforcement agencies can efficiently identify currency without actually marking it. This provides an undetectable means for making each note individually traceable and facilitates record keeping for providing evidence in a court of law. In addition when multiple systems are used in conjunction with a central data base the system can be used to track currency geographically. 1.

  16. CCD characterization and measurements automation

    International Nuclear Information System (INIS)

    Kotov, I.V.; Frank, J.; Kotov, A.I.; Kubanek, P.; O'Connor, P.; Prouza, M.; Radeka, V.; Takacs, P.

    2012-01-01

    Modern mosaic cameras have grown both in size and in number of sensors. The required volume of sensor testing and characterization has grown accordingly. For camera projects as large as the LSST, test automation becomes a necessity. A CCD testing and characterization laboratory was built and is in operation for the LSST project. Characterization of LSST study contract sensors has been performed. The characterization process and its automation are discussed, and results are presented. Our system automatically acquires images, populates a database with metadata information, and runs express analysis. This approach is illustrated on 55 Fe data analysis. 55 Fe data are used to measure gain, charge transfer efficiency and charge diffusion. Examples of express analysis results are presented and discussed.

  17. The Cross-Cultural Dementia Screening (CCD): A new neuropsychological screening instrument for dementia in elderly immigrants.

    Science.gov (United States)

    Goudsmit, Miriam; Uysal-Bozkir, Özgül; Parlevliet, Juliette L; van Campen, Jos P C M; de Rooij, Sophia E; Schmand, Ben

    2017-03-01

    Currently, approximately 3.9% of the European population are non-EU citizens, and a large part of these people are from "non-Western" societies, such as Turkey and Morocco. For various reasons, the incidence of dementia in this group is expected to increase. However, cognitive testing is challenging due to language barriers and low education and/or illiteracy. The newly developed Cross-Cultural Dementia Screening (CCD) can be administered without an interpreter. It contains three subtests that assess memory, mental speed, and executive function. We hypothesized the CCD to be a culture-fair test that could discriminate between demented patients and cognitively healthy controls. To test this hypothesis, 54 patients who had probable dementia were recruited via memory clinics. Controls (N = 1625) were recruited via their general practitioners. All patients and controls were aged 55 years and older and of six different self-defined ethnicities (Dutch, Turkish, Moroccan-Arabic, Moroccan-Berber, Surinamese-Creole, and Surinamese-Hindustani). Exclusion criteria included current or previous conditions that affect cognitive functioning. There were performance differences between the ethnic groups, but these disappeared after correcting for age and education differences between the groups, which supports our central hypothesis that the CCD is a culture-fair test. Receiver-operating characteristic (ROC) and logistic regression analyses showed that the CCD has high predictive validity for dementia (sensitivity: 85%; specificity: 89%). The CCD is a sensitive and culture-fair neuropsychological instrument for dementia screening in low-educated immigrant populations.

  18. New design for the UCO/Lick Observatory CCD guide camera

    Science.gov (United States)

    Wei, Mingzhi; Stover, Richard J.

    1996-03-01

    A new CCD based field acquisition and telescope guiding camera is being designed and built at UCO/Lick Observatory. Our goal is a camera which is fully computer controllable, compact in size, versatile enough to provide a wide variety of image acquisition modes, and able to operate with a wide variety of CCD detectors. The camera will improve our remote-observing capabilities since it will be easy to control the camera and obtain images over the Observatory computer network. To achieve the desired level of operating flexibility, the design incorporates state-of-the-art technologies such as high density, high speed programmable logic devices and non-volatile static memory. Various types of CCDs can be used in this system without major modification of the hardware or software. Though fully computer controllable, the camera can be operated as a stand-alone unit with most operating parameters set locally. A stand-alone display subsystem is also available. A thermoelectric device is used to cool the CCD to about -45c. Integration times can be varied over a range of 0.1 to 1000 seconds. High speed pixel skipping in both horizontal and vertical directions allows us to quickly access a selected subarea of the detector. Three different read out speeds allow the astronomer to select between high-speed/high-noise and low-speed/low-noise operation. On- chip pixel binning and MPP operation are also selectable options. This system can provide automatic sky level measurement and subtraction to accommodate dynamically changing background levels.

  19. Fast event recorder utilizing a CCD analog shift register

    International Nuclear Information System (INIS)

    Ducar, R.J.; McIntyre, P.M.

    1978-01-01

    A system of electronics has been developed to allow the capture and recording of relatively fast, low-amplitude analog events. The heart of the system is a dual 455-cell analog shift register charge-coupled device, Fairchild CCD321ADC-3. The CCD is operated in a dual clock mode. The input is sampled at a selectable clock rate of .25-20 MHz. The stored analog data is then clocked out at a slower rate, typically about .25 MHz. The time base expansion of the analog data allows for analog-to-digital conversion and memory storage using conventional medium-speed devices. The digital data is sequentially loaded into a static RAM and may then be block transferred to a computer. The analog electronics are housed in a single-width NIM module, and the RAM memory in a single-width CAMAC module. Each pair of modules provides six parallel channels. Cost is about $200.00 per channel. Applications are described for ionization imaging (TPC, IRC) and long-drift calorimetry in liquid argon

  20. Comparison of a CCD and an APS for soft X-ray diffraction

    International Nuclear Information System (INIS)

    Stewart, Graeme; Bates, R; Blue, A; Maneuski, D; Clark, A; Turchetta, R; Dhesi, S S; Marchal, J; Steadman, P; Tartoni, N

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  1. Comparison of a CCD and an APS for soft X-ray diffraction

    Science.gov (United States)

    Stewart, Graeme; Bates, R.; Blue, A.; Clark, A.; Dhesi, S. S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-12-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  2. The possibilities of CCD photometry of optical afterglows of GRBs

    Czech Academy of Sciences Publication Activity Database

    Šimon, Vojtěch; Polášek, Cyril; Jelínek, M.; Hudec, René; Štrobl, Jan

    -, č. 125 (2010), s. 24-28 ISSN 1801-5964. [Conference on Variable Stars Research /41./. Prague, 27.11.2009-29.11.2009] Institutional research plan: CEZ:AV0Z10030501 Keywords : gamma-ray bursts * optical afterglows * CCD photometry Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  3. Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method

    Science.gov (United States)

    Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao

    2016-09-01

    To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.

  4. BVRI CCD photometry of the globular cluster NGC 2808

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.; Wenderoth, E.

    1990-01-01

    As a part of a continuing program, CCD color-magnitude diagrams are presented for the bright globular cluster NGC 2808 in the four colors comprising BVRI. From a comparison of four different CMDs with theoretical isochrones, an age of 16 + or - 2 Gyr is obtained, assuming a value for Fe/H near -1.3. 28 refs

  5. A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film

    Energy Technology Data Exchange (ETDEWEB)

    Han, Won Jeong [Dankook University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora FMX, Orion Co./Soredex, Helsinki, Finland) and 1 film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (AZ). Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  6. A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2004-01-01

    To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora FMX, Orion Co./Soredex, Helsinki, Finland) and 1 film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (AZ). Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  7. Measuring a narrow Bessel beam spot by scanning a charge-coupled device (CCD) pixel

    International Nuclear Information System (INIS)

    Tiwari, S K; Ram, S P; Jayabalan, J; Mishra, S R

    2010-01-01

    By scanning a charge-coupled device (CCD) camera transverse to the beam axis and observing the variation in counts on a marked pixel, we demonstrate that we can measure a laser beam spot size smaller than the size of the CCD-pixel. We find this method particularly attractive for measuring the size of central spot of a Bessel beam, for which the established scanning knife-edge method does not work appropriately because of the large contribution of the rings surrounding the central spot to the signal

  8. Bilateral Neuropathy of Primary Sensory Neurons by the Chronic Compression of Multiple Unilateral DRGs

    Directory of Open Access Journals (Sweden)

    Ya-Bin Xie

    2016-01-01

    Full Text Available To mimic multilevel nerve root compression and intervertebral foramina stenosis in human, we established a new animal model of the chronic compression of unilateral multiple lumbar DRGs (mCCD in the rat. A higher occurrence of signs of spontaneous pain behaviors, such as wet-dog shaking and spontaneous hind paw shrinking behaviors, was firstly observed from day 1 onward. In the meantime, the unilateral mCCD rat exhibited significant bilateral hind paw mechanical and cold allodynia and hyperalgesia, as well as a thermal preference to 30°C plate between 30 and 35°C. The expression of activating transcription factor 3 (ATF3 was significantly increased in the ipsilateral and contralateral all-sized DRG neurons after the mCCD. And the expression of CGRP was significantly increased in the ipsilateral and contralateral large- and medium-sized DRG neurons. ATF3 and CGRP expressions correlated to evoked pain hypersensitivities such as mechanical and cold allodynia on postoperative day 1. The results suggested that bilateral neuropathy of primary sensory neurons might contribute to bilateral hypersensitivity in the mCCD rat.

  9. 3D velocity measurements in fluid flows using multiple exposure holography

    International Nuclear Information System (INIS)

    Stanislas, M.; Rodriguez, O.; Dadi, M.; Beluche, F.

    1987-01-01

    An account is given of multiple exposure holography's application to the measurement of velocity in fluid flows. The method is nonintrusive, and yields access to the three components of the instantaneous velocity in three-dimensional domains. These characteristics render such holographic data complementary to classical LDV. Attention is given to solutions proposed for such limitations inherent in the method as the rather lengthy acquisition time; this difficulty is presently addressed by means of an automated evaluation methodology. 12 references

  10. CCD-based vertex detectors

    CERN Document Server

    Damerell, C J S

    2005-01-01

    Over the past 20 years, CCD-based vertex detectors have been used to construct some of the most precise 'tracking microscopes' in particle physics. They were initially used by the ACCMOR collaboration for fixed target experiments in CERN, where they enabled the lifetimes of some of the shortest-lived charm particles to be measured precisely. The migration to collider experiments was accomplished in the SLD experiment, where the original 120 Mpixel detector was later upgraded to one with 307 Mpixels. This detector was used in a range of physics studies which exceeded the capability of the LEP detectors, including the most precise limit to date on the Bs mixing parameter. This success, and the high background hit densities that will inevitably be encountered at the future TeV-scale linear collider, have established the need for a silicon pixel-based vertex detector at this machine. The technical options have now been broadened to include a wide range of possible silicon imaging technologies as well as CCDs (mon...

  11. Measuring high-resolution sky luminance distributions with a CCD camera.

    Science.gov (United States)

    Tohsing, Korntip; Schrempf, Michael; Riechelmann, Stefan; Schilke, Holger; Seckmeyer, Gunther

    2013-03-10

    We describe how sky luminance can be derived from a newly developed hemispherical sky imager (HSI) system. The system contains a commercial compact charge coupled device (CCD) camera equipped with a fish-eye lens. The projection of the camera system has been found to be nearly equidistant. The luminance from the high dynamic range images has been calculated and then validated with luminance data measured by a CCD array spectroradiometer. The deviation between both datasets is less than 10% for cloudless and completely overcast skies, and differs by no more than 20% for all sky conditions. The global illuminance derived from the HSI pictures deviates by less than 5% and 20% under cloudless and cloudy skies for solar zenith angles less than 80°, respectively. This system is therefore capable of measuring sky luminance with the high spatial and temporal resolution of more than a million pixels and every 20 s respectively.

  12. Recording of radiation-induced optical density changes in doped agarose gels with a CCD camera

    International Nuclear Information System (INIS)

    Tarte, B.J.; Jardine, P.A.; Van Doorn, T.

    1996-01-01

    Full text: Spatially resolved dose measurement with iron-doped agarose gels is continuing to be investigated for applications in radiotherapy dosimetry. It has previously been proposed to use optical methods, rather than MRI, for dose measurement with such gels and this has been investigated using a spectrophotometer (Appleby A and Leghrouz A, Med Phys, 18:309-312, 1991). We have previously studied the use of a pencil beam laser for such optical density measurement of gels and are currently investigating charge-coupled devices (CCD) camera imaging for the same purpose but with the advantages of higher data acquisition rates and potentially greater spatial resolution. The gels used in these studies were poured, irradiated and optically analysed in Perspex casts providing gel sections 1 cm thick and up to 20 cm x 30 cm in dimension. The gels were also infused with a metal indicator dye (xylenol orange) to render the radiation induced oxidation of the iron in the gel sensitive to optical radiation, specifically in the green spectral region. Data acquisition with the CCD camera involved illumination of the irradiated gel section with a diffuse white light source, with the light from the plane of the gel section focussed to the CCD array with a manual zoom lens. The light was also filtered with a green colour glass filter to maximise the contrast between unirradiated and irradiated gels. The CCD camera (EG and G Reticon MC4013) featured a 1024 x 1024 pixel array and was interfaced to a PC via a frame grabber acquisition board with 8 bit resolution. The performance of the gel dosimeter was appraised in mapping of physical and dynamic wedged 6 MV X-ray fields. The results from the CCD camera detection system were compared with both ionisation chamber data and laser based optical density measurements of the gels. Cross beam profiles were extracted from each measurement system at a particular depth (eg. 2.3 cm for the physical wedge field) for direct comparison. A

  13. Stroboscope Based Synchronization of Full Frame CCD Sensors

    OpenAIRE

    Shen, Liang; Feng, Xiaobing; Zhang, Yuan; Shi, Min; Zhu, Dengming; Wang, Zhaoqi

    2017-01-01

    The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equi...

  14. STARL -- a Program to Correct CCD Image Defects

    Science.gov (United States)

    Narbutis, D.; Vanagas, R.; Vansevičius, V.

    We present a program tool, STARL, designed for automatic detection and correction of various defects in CCD images. It uses genetic algorithm for deblending and restoring of overlapping saturated stars in crowded stellar fields. Using Subaru Telescope Suprime-Cam images we demonstrate that the program can be implemented in the wide-field survey data processing pipelines for production of high quality color mosaics. The source code and examples are available at the STARL website.

  15. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    DEFF Research Database (Denmark)

    Freiesleben, Trine Holm; Sohbati, Reza; Murray, Andrew

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure...... and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescenceedepth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated...... events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible...

  16. Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.

    Science.gov (United States)

    Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin

    2012-10-01

    An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.

  17. Flat Field Anomalies in an X-Ray CCD Camera Measured Using a Manson X-Ray Source

    International Nuclear Information System (INIS)

    Michael Haugh

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. It determines how accurately NIF can point the laser beams and is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 2mA, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 12. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1.5% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. The efficiency pattern follows the properties of Si. The maximum quantum efficiency is 0.71. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation was >8% at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was less than the measurement uncertainty below 4 keV. We were also able to observe debris on the CCD chip. The debris showed maximum contrast at the lowest energy used, 930 eV, and disappeared by 4 keV. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  18. An X-ray CCD signal generator with true random arrival time

    International Nuclear Information System (INIS)

    Huo Jia; Xu Yuming; Chen Yong; Cui Weiwei; Li Wei; Zhang Ziliang; Han Dawei; Wang Yusan; Wang Juan

    2011-01-01

    An FPGA-based true random signal generator with adjustable amplitude and exponential distribution of time interval is presented. Since traditional true random number generators (TRNG) are resource costly and difficult to transplant, we employed a method of random number generation based on jitter and phase noise in ring oscillators formed by gates in an FPGA. In order to improve the random characteristics, a combination of two different pseudo-random processing circuits is used for post processing. The effects of the design parameters, such as sample frequency are discussed. Statistical tests indicate that the generator can well simulate the timing behavior of random signals with Poisson distribution. The X-ray CCD signal generator will be used in debugging the CCD readout system of the Low Energy X-ray Instrument onboard the Hard X-ray Modulation Telescope (HXMT). (authors)

  19. Dynamic Mapping of Rice Growth Parameters Using HJ-1 CCD Time Series Data

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2016-11-01

    Full Text Available The high temporal resolution (4-day charge-coupled device (CCD cameras onboard small environment and disaster monitoring and forecasting satellites (HJ-1A/B with 30 m spatial resolution and large swath (700 km have substantially increased the availability of regional clear sky optical remote sensing data. For the application of dynamic mapping of rice growth parameters, leaf area index (LAI and aboveground biomass (AGB were considered as plant growth indicators. The HJ-1 CCD-derived vegetation indices (VIs showed robust relationships with rice growth parameters. Cumulative VIs showed strong performance for the estimation of total dry AGB. The cross-validation coefficient of determination ( R C V 2 was increased by using two machine learning methods, i.e., a back propagation neural network (BPNN and a support vector machine (SVM compared with traditional regression equations of LAI retrieval. The LAI inversion accuracy was further improved by dividing the rice growth period into before and after heading stages. This study demonstrated that continuous rice growth monitoring over time and space at field level can be implemented effectively with HJ-1 CCD 10-day composite data using a combination of proper VIs and regression models.

  20. Developing a CCD camera with high spatial resolution for RIXS in the soft X-ray range

    Science.gov (United States)

    Soman, M. R.; Hall, D. J.; Tutt, J. H.; Murray, N. J.; Holland, A. D.; Schmitt, T.; Raabe, J.; Schmitt, B.

    2013-12-01

    The Super Advanced X-ray Emission Spectrometer (SAXES) at the Swiss Light Source contains a high resolution Charge-Coupled Device (CCD) camera used for Resonant Inelastic X-ray Scattering (RIXS). Using the current CCD-based camera system, the energy-dispersive spectrometer has an energy resolution (E/ΔE) of approximately 12,000 at 930 eV. A recent study predicted that through an upgrade to the grating and camera system, the energy resolution could be improved by a factor of 2. In order to achieve this goal in the spectral domain, the spatial resolution of the CCD must be improved to better than 5 μm from the current 24 μm spatial resolution (FWHM). The 400 eV-1600 eV energy X-rays detected by this spectrometer primarily interact within the field free region of the CCD, producing electron clouds which will diffuse isotropically until they reach the depleted region and buried channel. This diffusion of the charge leads to events which are split across several pixels. Through the analysis of the charge distribution across the pixels, various centroiding techniques can be used to pinpoint the spatial location of the X-ray interaction to the sub-pixel level, greatly improving the spatial resolution achieved. Using the PolLux soft X-ray microspectroscopy endstation at the Swiss Light Source, a beam of X-rays of energies from 200 eV to 1400 eV can be focused down to a spot size of approximately 20 nm. Scanning this spot across the 16 μm square pixels allows the sub-pixel response to be investigated. Previous work has demonstrated the potential improvement in spatial resolution achievable by centroiding events in a standard CCD. An Electron-Multiplying CCD (EM-CCD) has been used to improve the signal to effective readout noise ratio achieved resulting in a worst-case spatial resolution measurement of 4.5±0.2 μm and 3.9±0.1 μm at 530 eV and 680 eV respectively. A method is described that allows the contribution of the X-ray spot size to be deconvolved from these

  1. A data-acquisition system for high speed linear CCD

    International Nuclear Information System (INIS)

    Liu Zhiyan; Chen Xiangcai; Jiang Xiaoshan; Zhang Hongyu; Liang Zhongwang; Xiang Haisheng; Hu Jun

    2010-01-01

    A data-acquisition system for high speed linear CCD (Charge Coupled device) is mainly introduced. The optical fiber transmission technology is used. The data is sent to PC through USB or PCI interface. The construction of the system, the design of the PCI interface hardware, software design and the design of the control program running on host computer are also introduced. (authors)

  2. Measurements of 42 Wide CPM Pairs with a CCD

    Science.gov (United States)

    Harshaw, Richard

    2015-11-01

    This paper addresses the use of a Skyris 618C color CCD camera as a means of obtaining data for analysis in the measurement of wide common proper motion stars. The equipment setup is described and data collection procedure outlined. Results of the measures of 42 CPM stars are presented, showing the Skyris is a reliable device for the measurement of double stars.

  3. Exposure estimates based on broadband elf magnetic field measurements versus the ICNIRP multiple frequency rule

    International Nuclear Information System (INIS)

    Paniagua, Jesus M.; Rufo, Montana; Jimenez, Antonio; Pachon, Fernando T.; Carrero, Julian

    2015-01-01

    The evaluation of exposure to extremely low-frequency (ELF) magnetic fields using broadband measurement techniques gives satisfactory results when the field has essentially a single frequency. Nevertheless, magnetic fields are in most cases distorted by harmonic components. This work analyses the harmonic components of the ELF magnetic field in an outdoor urban context and compares the evaluation of the exposure based on broadband measurements with that based on spectral analysis. The multiple frequency rule of the International Commission on Non-ionizing Radiation Protection (ICNIRP) regulatory guidelines was applied. With the 1998 ICNIRP guideline, harmonics dominated the exposure with a 55 % contribution. With the 2010 ICNIRP guideline, however, the primary frequency dominated the exposure with a 78 % contribution. Values of the exposure based on spectral analysis were significantly higher than those based on broadband measurements. Hence, it is clearly necessary to determine the harmonic components of the ELF magnetic field to assess exposure in urban contexts. (authors)

  4. Design method of general-purpose driving circuit for CCD based on CPLD

    International Nuclear Information System (INIS)

    Zhang Yong; Tang Benqi; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2005-01-01

    It is very important for studying the radiation damage effects and mechanism systematically about CCD to develop a general-purpose test platform. The paper discusses the design method of general-purpose driving circuit for CCD based on CPLD and the realization approach. A main controller has being designed to read the data file from the outer memory, setup the correlative parameter registers and produce the driving pulses according with parameter request strictly, which is based on MAX7000S by using MAX-PLUS II software. The basic driving circuit module has being finished based on this method. The output waveform of the module is the same figure as the simulation waveform. The result indicates that the design method is feasible. (authors)

  5. Single-exposure two-dimensional superresolution in digital holography using a vertical cavity surface-emitting laser source array.

    Science.gov (United States)

    Granero, Luis; Zalevsky, Zeev; Micó, Vicente

    2011-04-01

    We present a new implementation capable of producing two-dimensional (2D) superresolution (SR) imaging in a single exposure by aperture synthesis in digital lensless Fourier holography when using angular multiplexing provided by a vertical cavity surface-emitting laser source array. The system performs the recording in a single CCD snapshot of a multiplexed hologram coming from the incoherent addition of multiple subholograms, where each contains information about a different 2D spatial frequency band of the object's spectrum. Thus, a set of nonoverlapping bandpass images of the input object can be recovered by Fourier transformation (FT) of the multiplexed hologram. The SR is obtained by coherent addition of the information contained in each bandpass image while generating an enlarged synthetic aperture. Experimental results demonstrate improvement in resolution and image quality.

  6. OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

    Science.gov (United States)

    Collins, Nick

    2009-01-01

    The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a

  7. Two Herbig-Haro objects discovered by narrow-band CCD imagery

    International Nuclear Information System (INIS)

    Ogura, Katsuo

    1990-01-01

    Two new Herbig-Haro objects, HH 132 and HH 133, have been discovered by CCD imagery behind interference filters on and just off the forbidden S II lines in the red. They are located in Puppis R2 and in Vela R2. Possible locations of their exciting sources are discussed. 12 refs

  8. CCD polarimetry as a probe of regions of recent-star formation

    Energy Technology Data Exchange (ETDEWEB)

    Draper, P W

    1988-01-01

    Chapter 1 of this thesis details the incorporation of a Charged-Coupled Device (CCD) detector system with the Durham Imaging Polarimeter. The details include the physical characteristics of the device and the electronics and software associated with the device control and data storage. Chapter 2 of this work describes fully how suitable corrections for this effect can be made, and derives first-order results. The CCD performance is examined in comparison with the detector used previously and hence the veracity of the new results is established. Chapter 3 is a relevant summary of the status of the astronomy of the immediate regions of recent-star formation. Chapter 4 describes multicolor polarimetry of NGC2261/R Mon covering the period 1979 to 1986. The data conclusively prove that the polarization of R Mon must be due to effects close to R Mon (approx.14 astronomical units).

  9. A simple and accurate method for the quality control of the I.I.-DR apparatus using the CCD camera

    International Nuclear Information System (INIS)

    Igarashi, Hitoshi; Shiraishi, Akihisa; Kuraishi, Masahiko

    2000-01-01

    With the advancing development of CCD cameras, the I.I.-DR apparatus has been introduced into the x-ray fluoroscopy television system. Consequently, quality control of the system has become a complicated task. We developed a simple, accurate method for quality control of the I.I.-DR apparatus using the CCD camera. Experiments were separately performed for the imager system [laser imager, DDX (dynamic digital x-ray system)] and the imaging system (I.I., ND-filter, IRIS, CCD camera). Quality control of the imager system was done by simply examining both input and output characteristics with a sliding pattern. Quality control of the imaging system was also conducted by estimating AVE (the average volume element), which was obtained using a phantom under the constant conditions. The results indicated that this simplified method is useful as a weekly quality control check of the I.I.-DR apparatus using the CCD camera. (author)

  10. A CCD-based area detector for X-ray crystallography using synchrotron and laboratory sources

    International Nuclear Information System (INIS)

    Phillips, W.C.; Li Youli; Stanton, M.; Xie Yuanhui; O'Mara, D.; Kalata, K.

    1993-01-01

    The design and characteristics of a CCD-based area detector suitable for X-ray crystallographic studies using both synchrotron and laboratory sources are described. The active area is 75 mm in diameter, the FWHM of the point response function is 0.20 mm, and for Bragg peaks the dynamic range is 900 and the DQE ∼0.3. The 1320x1035-pixel Kodak CCD is read out into an 8 Mbyte memory system in 0.14 s and digitized to 12 bits. X-ray crystallographic data collected at the NSLS synchrotron from cubic insulin crystals are presented. (orig.)

  11. Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer.

    Science.gov (United States)

    Das, Bhargab; Chandra, Vikash

    2016-10-10

    We present an experimental comparative study of the two most commonly used fiber Bragg grating (FBG) sensor interrogation techniques: a charge-coupled device (CCD) spectrometer and a fiber Mach-Zehnder interferometer (F-MZI). Although the interferometric interrogation technique is historically known to offer the highest sensitivity measurements, very little information exists regarding how it compares with the current commercially available spectral-characteristics-based interrogation systems. It is experimentally established here that the performance of a modern-day CCD spectrometer interrogator is very close to a F-MZI interrogator with the capability of measuring Bragg wavelength shifts with sub-picometer-level accuracy. The results presented in this research study can further be used as a guideline for choosing between the two FBG sensor interrogator types for small-amplitude dynamic perturbation measurements down to nano-level strain.

  12. Use of a CCD-based area detection system of a fibre diffractometer

    International Nuclear Information System (INIS)

    Hanna, S.; Windle, A.H.

    1995-01-01

    We describe a new X-ray fibre diffractometer, consisting of a commercial X-ray sensitive video camera coupled to a conventional 3 goniometer in place of a more traditional single-point detector. The active element of the video camera is a charge-coupled device (CCD). Diffraction images, obtained at various goniometer settings, are transformed into reciprocal space, and combined to give a complete section through the origin and parallel to the symmetry axis of cylindrically averaged reciprocal space. A greater density of measurements is needed in the vicinity of the reciprocal fibre axis in order to avoid information loss due to the curvature of the Ewald sphere. The pros and cons of using CCD's as X-ray detectors are discussed and sample results from polymer fibers are shown. 17 refs., 5 figs

  13. CCD Development Progress at Lawrence Berkeley National Laboratory

    OpenAIRE

    Kolbe, W.F.; Holland, S.E.; Bebek, C.J.

    2006-01-01

    P-channel CCD imagers, 200-300um thick, fully depleted, and back-illuminat ed are being developed for scientific applications including ground- and space-based astronomy and x-ray detection. These thick devices have extended IR response, good point-spread function (PSF) and excellent radiation tolerance. Initially, these CCDs were made in-house at LBNL using 100 mm diameter wafers. Fabrication on high-resistivity 150 mm wafers is now proceeding according to a model in which the wafers are fir...

  14. CCD high-speed videography system with new concepts and techniques

    Science.gov (United States)

    Zheng, Zengrong; Zhao, Wenyi; Wu, Zhiqiang

    1997-05-01

    A novel CCD high speed videography system with brand-new concepts and techniques is developed by Zhejiang University recently. The system can send a series of short flash pulses to the moving object. All of the parameters, such as flash numbers, flash durations, flash intervals, flash intensities and flash colors, can be controlled according to needs by the computer. A series of moving object images frozen by flash pulses, carried information of moving object, are recorded by a CCD video camera, and result images are sent to a computer to be frozen, recognized and processed with special hardware and software. Obtained parameters can be displayed, output as remote controlling signals or written into CD. The highest videography frequency is 30,000 images per second. The shortest image freezing time is several microseconds. The system has been applied to wide fields of energy, chemistry, medicine, biological engineering, aero- dynamics, explosion, multi-phase flow, mechanics, vibration, athletic training, weapon development and national defense engineering. It can also be used in production streamline to carry out the online, real-time monitoring and controlling.

  15. LAMOST CCD camera-control system based on RTS2

    Science.gov (United States)

    Tian, Yuan; Wang, Zheng; Li, Jian; Cao, Zi-Huang; Dai, Wei; Wei, Shou-Lin; Zhao, Yong-Heng

    2018-05-01

    The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is the largest existing spectroscopic survey telescope, having 32 scientific charge-coupled-device (CCD) cameras for acquiring spectra. Stability and automation of the camera-control software are essential, but cannot be provided by the existing system. The Remote Telescope System 2nd Version (RTS2) is an open-source and automatic observatory-control system. However, all previous RTS2 applications were developed for small telescopes. This paper focuses on implementation of an RTS2-based camera-control system for the 32 CCDs of LAMOST. A virtual camera module inherited from the RTS2 camera module is built as a device component working on the RTS2 framework. To improve the controllability and robustness, a virtualized layer is designed using the master-slave software paradigm, and the virtual camera module is mapped to the 32 real cameras of LAMOST. The new system is deployed in the actual environment and experimentally tested. Finally, multiple observations are conducted using this new RTS2-framework-based control system. The new camera-control system is found to satisfy the requirements for automatic camera control in LAMOST. This is the first time that RTS2 has been applied to a large telescope, and provides a referential solution for full RTS2 introduction to the LAMOST observatory control system.

  16. Lyssavirus infection: 'low dose, multiple exposure' in the mouse model.

    Science.gov (United States)

    Banyard, Ashley C; Healy, Derek M; Brookes, Sharon M; Voller, Katja; Hicks, Daniel J; Núñez, Alejandro; Fooks, Anthony R

    2014-03-06

    quaternary inoculations although the serological response did not necessarily reflect the repeated exposure. We conclude that despite repeated exposure, neither clinical disease nor serological response can be predicted and that further studies are required to understand the mechanisms behind survival following multiple exposures to lyssaviruses. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  17. Caracterização espectral de áreas de gramíneas forrageiras infectadas com a doença "mela-das-sementes da braquiária" por meio de imagens CCD/CBERS-2 Spectral characterization of forage grasses infected with the disease "mela-das-sementes da braquiária" through CCD/CDBERS -2 images

    Directory of Open Access Journals (Sweden)

    José C. Rosatti

    2006-12-01

    Full Text Available Imagens CCD/CBERS-2, nas bandas espectrais CCD2, CCD3 e CCD4, dos anos de 2004 e 2005, de Mirante do Paranapanema - SP, foram transformadas em reflectância de superfície usando o modelo 5S de correção atmosférica e normalizadas radiometricamente. O objetivo principal foi caracterizar espectralmente áreas de pastagens de Brachiaria brizantha em fase de florescimento, isentas e infectadas com a doença "mela-das-sementes da braquiária", possibilitando a sua detecção por meio da comparação entre os valores de reflectância de superfície denominada de Fator de Reflectância Bidirecional de Superfície (FRBS. Teve-se, também, o objetivo de avaliar a eficácia das imagens CCD/CBERS-2 para a obtenção de respostas espectrais de pastagens. Os dosséis sadios e doentes da Brachiaria brizantha foram identificados por meio da análise dos valores de reflectância e dos dados observados no Índice de Estresse Hídrico Acumulativo Relativo da Cultura (ACWSI obtidos na área de estudo. Os resultados indicaram que as principais diferenças foram a diminuição da reflectância na banda CCD3 e o aumento da reflectância na banda CCD4 nas áreas doentes. A metodologia empregada com o uso de dados do sensor CCD/CBERS-2, associados ao ACWSI, mostrou-se eficaz para discriminar dosséis infectados com a "mela-das-sementes da braquiária".CCD/CBERS-2 images in the spectral bands of CCD2, CCD3 and CCD4 of the years 2004 and 2005, from Mirante do Paranapanema - SP (Brazil, were transformed into surface reflectance images using the 5S atmospheric correction model and radiometrically normalized. The main objective was to spectrally characterize pastures of Brachiaria brizantha in the flowering phase, exempt and infected with the disease "mela-das-sementes da braquiária" making it possible its detection through the comparison among the SBRF - Surface Bidirectional Reflectance Factor values. At the same time, it was aimed to evaluate the effectiveness of the

  18. CCD photometry of Cepheid sequences in four nearby galaxies

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.

    1991-01-01

    We present Isaac Newton Telescope B and V CCD observations of deep photometric sequences in the vicinity of Cepheid variable stars in three nearby galaxies - M31, M33 and NGC 2403. We have also checked the photometry of the brightest stars in M81 and its dwarf companion, Holmberg IX. We use our data, combined with other recent results, to re-analyse the Cepheid distances to these galaxies. (author)

  19. Measuring neutron fluences and gamma/x-ray fluxes with CCD cameras

    International Nuclear Information System (INIS)

    Yates, G.J.; Smith, G.W.; Zagarino, P.; Thomas, M.C.

    1991-01-01

    The capability to measure bursts of neutron fluences and gamma/x-ray fluxes directly with charge coupled device (CCD) cameras while being able to distinguish between the video signals produced by these two types of radiation, even when they occur simultaneously, has been demonstrated. Volume and area measurements of transient radiation-induced pixel charge in English Electric Valve (EEV) Frame Transfer (FT) charge coupled devices (CCDs) from irradiation with pulsed neutrons (14 MeV) and Bremsstrahlung photons (4--12 MeV endpoint) are utilized to calibrate the devices as radiometric imaging sensors capable of distinguishing between the two types of ionizing radiation. Measurements indicate ∼.05 V/rad responsivity with ≥1 rad required for saturation from photon irradiation. Neutron-generated localized charge centers or ''peaks'' binned by area and amplitude as functions of fluence in the 10 5 to 10 7 n/cm 2 range indicate smearing over ∼1 to 10% of CCD array with charge per pixel ranging between noise and saturation levels

  20. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC[reg] film

    International Nuclear Information System (INIS)

    Lynch, Bart D.; Kozelka, Jakub; Ranade, Manisha K.; Li, Jonathan G.; Simon, William E.; Dempsey, James F.

    2006-01-01

    In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC[reg] EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression 1680 CCD array scanner, and a Microtek ScanMaker i900 CCD array scanner. For the two scanners we assessed the variation in optical density (OD) of GAFCHROMIC EBT film with scanning bed position, angular rotation of the film with respect to the scan line direction, and temperature inside the scanner due to repeated scanning. Scanning uniform radiochromic films demonstrated a distinct bowing effect in profiles in the direction of the CCD array with a nonuniformity of up to 17%. Profiles along a direction orthogonal to the CCD array demonstrated a 7% variation. A strong angular dependence was found in measurements made with the flatbed scanners; the effect could not be reproduced with the spot densitometer. An IMRT quality assurance film was scanned twice rotating the film 90 deg. between the scans. For films scanned on the Epson scanner, up to 12% variation was observed in unirradiated EBT films rotated between 0 deg. and 90 deg. , which decreased to approximately 8% for EBT films irradiated to 300 cGy. Variations of up to 80% were observed for films scanned with the Microtek scanner. The scanners were found to significantly increase the film temperature with repeated scanning. Film temperature between 18 and 33 deg. C caused OD changes of approximately 7%. Considering these effects, we recommend adherence to a strict scanning protocol that includes: maintaining the orientation of films scanned on flatbed scanners, limiting scanning to the central portion of the scanner bed, and limiting the number of consecutive scans to minimize changes in OD caused by film heating

  1. BVRI CCD photometry of Omega Centauri

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.

    1987-01-01

    Color-magnitude diagrams (CMDs) of V vs B-V, V vs V-I, and V vs B-I have been constructed based on 179 BVRI CCD frames of two adjoining 4x2.5-arcmin fields in Omega Cen (NGC 5139) obtained with the 1.54-m Danish La Silla telescope. The spread in the main sequences noted in the three CMDs indicates that the wide range in chemical composition among the evolved stars in this cluster persists as well in the unevolved stars. This result suggests that the abundance variations are primordial. A difference in magnitude between the turnoff and the horizontal branch of 3.8 + or - 0.15 is found which is greater than a previous value. 38 references

  2. CCD photometry of NGC 2419

    International Nuclear Information System (INIS)

    Christian, C.A.; Heasley, J.N.

    1988-01-01

    The properties of the globular cluster NGC 2419 are reexamined using CCD photometry deepened to the vicinity of the main-sequence turnoff. A new color-magnitude diagram is derived that extends to V = 24.5 mag. It is concluded that NGC 2419 is an outer-halo analog of the metal-poor globulars closer to the Galactic center. NGC 2419 is probably nearly the same age as M15 and differs only slightly, if at all, in metallicity. NGC 2419 has many similarities with the clusters NGC 5466, M15, and M92. Comparison of the data with the isochrones of VandenBerg and Bell (1985) implies a distance modulus of 20.1 with Delta (B-V) = 0.18 mag. Oxygen-rich models can be fit to the data; such a comparison yields a lower limit to the acceptable distance modulus of the cluster. 26 references

  3. Ultraviolet downconverting phosphor for use with silicon CCD imagers

    Science.gov (United States)

    Blouke, M. M.; Cowens, M. W.; Hall, J. E.; Westphal, J. A.; Christensen, A. B.

    1980-01-01

    The properties and application of a UV downconverting phosphor (coronene) to silicon charge coupled devices are discussed. Measurements of the absorption spectrum have been extended to below 1000 A, and preliminary results indicate the existence of useful response to at least 584 A. The average conversion efficiency of coronene was measured to be approximately 20% at 2537 A. Imagery at 3650 A using a backside illuminated 800 x 800 CCD coated with coronene is presented.

  4. Characterization of a 512x512-pixel 8-output full-frame CCD for high-speed imaging

    Science.gov (United States)

    Graeve, Thorsten; Dereniak, Eustace L.

    1993-01-01

    The characterization of a 512 by 512 pixel, eight-output full frame CCD manufactured by English Electric Valve under part number CCD13 is discussed. This device is a high- resolution Silicon-based array designed for visible imaging applications at readout periods as low as two milliseconds. The characterization of the device includes mean-variance analysis to determine read noise and dynamic range, as well as charge transfer efficiency, MTF, and quantum efficiency measurements. Dark current and non-uniformity issues on a pixel-to-pixel basis and between individual outputs are also examined. The characterization of the device is restricted by hardware limitations to a one MHz pixel rate, corresponding to a 40 ms readout time. However, subsections of the device have been operated at up to an equivalent 100 frames per second. To maximize the frame rate, the CCD is illuminated by a synchronized strobe flash in between frame readouts. The effects of the strobe illumination on the imagery obtained from the device is discussed.

  5. The effects of multiple UV exposures on HIV-LTR (long terminal repeat) expression

    International Nuclear Information System (INIS)

    Schreck, S.; Milton, J.; Panozzo, J.; Libertin, C.R.; Woloschak, G.E.; Loyola Univ., Maywood, IL

    1995-01-01

    Previous studies have shown that cellular stress agents such as UV radiation induce transcription from the long terminal repeat (LTR) of the human immunodeficiency virus (HIV). Using HeLa cells stably transfected with the HIV-LTR sequence, which transcriptionally drives the chloramphenicol acetyl transferase (CAT) reporter gene, we examined the effects of multiple exposures to UVC (254 nm) on HIV-LTR-CAT expression. Low doses (≤ 5 J m -2 ) had no effect on CAT expression, but up to 29-fold induction was observed with 10 J m -2 when cells were harvested 48 h after completion of the exposure. Little difference was noted in induction levels when cells were exposed to one 25 J m -2 dose, viable cells were harvested at 24 h, 48 h or 72 h, and cell lysates were assayed for CAT expression. Two sequential 12.5 J m -2 exposures, given 24 h apart, resulted in an additive effect on CAT expression; these two exposures produced CAT activity equivalent to that induced following a single 25 J m -2 dose. Our data suggest that HIV-LTR requires a specific threshold UV dose in order to elicit induction; a maximal induction dose is also evident; exposures higher than this maximal dose contribute no more to HIV-LTR induction in viable cells. (author)

  6. CCD linear image sensor ILX511 arrangment for a technical spectrometer

    Czech Academy of Sciences Publication Activity Database

    Bartoněk, L.; Keprt, Jiří; Vlček, Martin

    2003-01-01

    Roč. 33, 2-3 (2003), s. 548-553 ISSN 0078-5466 Institutional research plan: CEZ:AV0Z1010921 Keywords : CCD linear sensor ILX511 * enhanced parallel port (EPP able IEEE1284) * A/D converter AD9280 Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.221, year: 2003

  7. Computer-aided diagnosis of pneumoconiosis abnormalities extracted from chest radiographs scanned with a CCD scanner

    International Nuclear Information System (INIS)

    Abe, Koji; Minami, Masahide; Nakamura, Munehiro

    2011-01-01

    This paper presents a computer-aided diagnosis for pneumoconiosis radiographs obtained with a common charge-coupled devices (CCD) scanner. Since the current computer-aided diagnosis systems of pneumoconiosis are not practical for medical doctors due to high costs of usage for a special scanner, we propose a novel system which measures abnormalities of pneumoconiosis from lung images obtained with a common CCD scanner. Experimental results of discriminations between normal and abnormal cases for 56 right-lung images including 6 standard pneumoconiosis images have shown that the proposed abnormalities are well extracted according to the standards of pneumoconiosis categories. (author)

  8. Atmospheric radiation environment analyses based-on CCD camera at various mountain altitudes and underground sites

    Directory of Open Access Journals (Sweden)

    Li Cavoli Pierre

    2016-01-01

    Full Text Available The purpose of this paper is to discriminate secondary atmospheric particles and identify muons by measuring the natural radiative environment in atmospheric and underground locations. A CCD camera has been used as a cosmic ray sensor. The Low Noise Underground Laboratory of Rustrel (LSBB, France gives the access to a unique low-noise scientific environment deep enough to ensure the screening from the neutron and proton radiative components. Analyses of the charge levels in pixels of the CCD camera induced by radiation events and cartographies of the charge events versus the hit pixel are proposed.

  9. Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory

    International Nuclear Information System (INIS)

    Gow, J P D; Murray, N J; Holland, A D; Hall, D J; Cropper, M; Burt, D; Hopkinson, G; Duvet, L

    2012-01-01

    Euclid is a medium class European Space Agency mission candidate for launch in 2019 with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements of distant galaxies. Therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCDs over the course of the 5 year mission at L2 are understood. This will allow, through experimental analysis and modelling techniques, the effects of radiation induced CTI on shape to be decoupled from those of mass inhomogeneities along the line-of-sight. This paper discusses a selection of work from the study that has been undertaken using the e2v CCD204 as part of the initial proton radiation damage assessment for Euclid. The experimental arrangement and procedure are described followed by the results obtained, thereby allowing recommendations to be made on the CCD operating temperature, to provide an insight into CTI effects using an optical background, to assess the benefits of using charge injection on CTI recovery and the effect of the use of two different methods of serial clocking on serial CTI. This work will form the basis of a comparison with a p-channel CCD204 fabricated using the same mask set as the n-channel equivalent. A custom CCD has been designed, based on this work and discussions between e2v technologies plc. and the Euclid consortium, and designated the CCD273.

  10. The astro-geodetic use of CCD for gravity field refinement

    Science.gov (United States)

    Gerstbach, G.

    1996-07-01

    The paper starts with a review of geoid projects, where vertical deflections are more effective than gravimetry. In alpine regions the economy of astrogeoids is at least 10 times higher, but many countries do not make use of this fact - presumably because the measurements are not fully automated up to now. Based upon the experiences of astrometry of high satellites and own tests the author analyses the use of CCD for astro-geodetic measurements. Automation and speeding up will be possible in a few years, the latter depending on the observation scheme. Sensor characteristics, cooling and reading out of the devices should be harmonized. Using line sensors in small prism astrolabes, the CCD accuracy will reach the visual one (±0.2″) within 5-10 years. Astrogeoids can be combined ideally with geological data, because vertical variation of rock densities does not cause systematic effects (contrary to gravimetry). So a geoid of ±5 cm accuracy (achieved in Austria and other alpine countries by 5-10 points per 1000 km 2) can be improved to ±2 cm without additional observations and border effects.

  11. House dust exposure mediates gut microbiome Lactobacillus enrichment and airway immune defense against allergens and virus infection.

    Science.gov (United States)

    Fujimura, Kei E; Demoor, Tine; Rauch, Marcus; Faruqi, Ali A; Jang, Sihyug; Johnson, Christine C; Boushey, Homer A; Zoratti, Edward; Ownby, Dennis; Lukacs, Nicholas W; Lynch, Susan V

    2014-01-14

    Exposure to dogs in early infancy has been shown to reduce the risk of childhood allergic disease development, and dog ownership is associated with a distinct house dust microbial exposure. Here, we demonstrate, using murine models, that exposure of mice to dog-associated house dust protects against ovalbumin or cockroach allergen-mediated airway pathology. Protected animals exhibited significant reduction in the total number of airway T cells, down-regulation of Th2-related airway responses, as well as mucin secretion. Following dog-associated dust exposure, the cecal microbiome of protected animals was extensively restructured with significant enrichment of, amongst others, Lactobacillus johnsonii. Supplementation of wild-type animals with L. johnsonii protected them against both airway allergen challenge or infection with respiratory syncytial virus. L. johnsonii-mediated protection was associated with significant reductions in the total number and proportion of activated CD11c(+)/CD11b(+) and CD11c(+)/CD8(+) cells, as well as significantly reduced airway Th2 cytokine expression. Our results reveal that exposure to dog-associated household dust results in protection against airway allergen challenge and a distinct gastrointestinal microbiome composition. Moreover, the study identifies L. johnsonii as a pivotal species within the gastrointestinal tract capable of influencing adaptive immunity at remote mucosal surfaces in a manner that is protective against a variety of respiratory insults.

  12. Puesta en marcha de un microdensitómetro automático basado en CCD

    Science.gov (United States)

    Calderón, J. H.; Bustos Fierro, I. H.

    We present the commisioning of a CCD-based microdensitometer intended to perform astrometric measurements of photographic plates. The work done consisted in the installation of a CCD camera, the modification of the motion system, the construction of a new illumination device, the adaptation of the electronics, and the development of software. The instrument is intended to be used for the astrometric measurement mainly of plates of the Astrographic Catalog and Carte du Ciel collections from Córdoba Observatory. In this phase of the project we counted with the collaboration of the Instituto Provincial de Enseñanza Media No 59, 25 de Mayo, Cruz Alta (Province of Córdoba). The origin and importance of such collaboration is commented.

  13. CCD Photometry of W UMa Type Binary TY UMa

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    2001-06-01

    Full Text Available We present VRI CCD photometry of W UMa type binary TY UMa. The light curves show that the secondary minimum is deeper than theprimary minimum and the maximum I (0.p25 is 0.m023 brighter than the maximum II (0.p75. The V light curve has beenanalyzed and the photometric solutions have been determined by the method of Wilson & Devinney differential correction. Weadopted the spot model to explain the asymetric light curve.

  14. A CCD fitted to the UV Prime spectrograph: Performance

    International Nuclear Information System (INIS)

    Boulade, O.

    1986-10-01

    A CCD camera was fitted to the 3.6 m French-Canadian telescope in Hawai. Performance of the system and observations of elliptic galaxies (stellar content and galactic evolution in a cluster) and quasars (absorption lines in spectra) are reported. In spite of its resolution being only average, the extremely rapid optics of the UV spectrograph gives good signal to noise ratios enabling redshifts and velocity scatter to be calculated with an accuracy better than 30 km/sec [fr

  15. Improving the resolution in soft X-ray emission spectrometers through photon-counting using an Electron Multiplying CCD

    International Nuclear Information System (INIS)

    Hall, D J; Soman, M; Tutt, J; Murray, N; Holland, A; Schmitt, T; Raabe, J; Strocov, V N; Schmitt, B

    2012-01-01

    In 2007, a study of back-illuminated Charge-Coupled Devices (CCDs) for soft X-ray photon detection demonstrated the improvements that could be brought over more traditional micro-channel plate detectors for X-ray spectrometers based on diffraction gratings and position sensitive detectors. Whilst the spatial resolution was reported to be improved dramatically, an intrinsic limit of approximately 25 micrometers was found due to the spreading of the charge cloud generated in the CCD across several pixels. To overcome this resolution limit, it is necessary to move away from the current integrated imaging methods and consider a photon-counting approach, recording the photon interaction locations to the sub-pixel level. To make use of photon-counting techniques it is important that the individual events are separable. To maintain the throughput of the spectrometer for high intensity lines, higher frame rates and therefore higher readout speeds are required. With CCD based systems, the increased noise at high readout speeds can limit the photon-counting performance. The Electron-Multiplying CCD shares a similar architecture with the standard CCD but incorporates a g ain register . This novel addition allows controllable gain to be applied to the signal before the read noise is introduced, therefore allowing individual events to be resolved above the noise even at much higher readout rates. In the past, the EM-CCD has only been available with imaging areas too small to be practical in soft X-ray emission spectrometers. The current drive for large area Electron-Multiplying CCDs is opening this technology to new photon-counting applications, requiring in-depth analysis of the processes and techniques involved. Early results indicate that through the introduction of photon-counting techniques the resolution in such systems can be dramatically improved.

  16. Researchers develop CCD image sensor with 20ns per row parallel readout time

    CERN Multimedia

    Bush, S

    2004-01-01

    "Scientists at the Rutherford Appleton Laboratory (RAL) in Oxfordshire have developed what they claim is the fastest CCD (charge-coupled device) image sensor, with a readout time which is 20ns per row" (1/2 page)

  17. Roentgenographic evaluation of the actual CCD and AT angle. Pt. 2

    International Nuclear Information System (INIS)

    Brueckl, R.; Grunert, S.; Rosemeyer, B.

    1986-01-01

    The method developed by Rippstein and Mueller allows a mathematically exact determination of the femoral neck-shaft angle (CCD) and the angle of torsion (AT); already at a deviation of 5-10 0 from the prescribed position of the patient considerable errors (up to more than 15 0 ) may occur. For this reason two alternative methods are cited and described in detail: a) the cinematographic determination of the CCD- and AT-angle according to Schwetlick, and b) the combination of the determination of the AT-angle in exterior rotation according to Rogers and an anteroposterior roentgenogram of the pelvis and hips in interior rotation of the size of the AT-angle. Both methods are also mathematically exact, however, in addition almost independent from minor deviations in the position of the patient. It is advisable to apply one of the cited methods in cases of high AT-angle values (>>30 0 ), in cases where the placing of the patient is difficult and where the determination of the angles would require a major therapeutic measurement. (orig.) [de

  18. An optical test bench for the precision characterization of absolute quantum efficiency for the TESS CCD detectors

    International Nuclear Information System (INIS)

    Krishnamurthy, A.; Villasenor, J.; Kissel, S.; Ricker, G.; Vanderspek, R.

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will search for planets transiting bright stars with Ic ∼< 13. TESS has been selected by NASA for launch in 2018 as an Astrophysics Explorer mission, and is expected to discover a thousand or more planets that are smaller in size than Neptune. TESS will employ four wide-field optical charge-coupled device (CCD) cameras with a band-pass of 650 nm–1050 nm to detect temporary drops in brightness of stars due to planetary transits. The 1050 nm limit is set by the quantum efficiency (QE) of the CCDs. The detector assembly consists of four back-illuminated MIT Lincoln Laboratory CCID-80 devices. Each CCID-80 device consists of 2048×2048 imaging array and 2048×2048 frame store regions. Very precise on-ground calibration and characterization of CCD detectors will significantly assist in the analysis of the science data obtained in space. The characterization of the absolute QE of the CCD detectors is a crucial part of the characterization process because QE affects the performance of the CCD significantly over the redder wavelengths at which TESS will be operating. An optical test bench with significantly high photometric stability has been developed to perform precise QE measurements. The design of the test setup along with key hardware, methodology, and results from the test campaign are presented.

  19. Optimal CCD readout by digital correlated double sampling

    Science.gov (United States)

    Alessandri, C.; Abusleme, A.; Guzman, D.; Passalacqua, I.; Alvarez-Fontecilla, E.; Guarini, M.

    2016-01-01

    Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better performance than traditional analogue readout techniques at the expense of a more complex system analysis. Several attempts to analyse and optimize a DCDS system have been reported, but most of the work presented in the literature has been experimental. Some approximate analytical tools have been presented for independent parameters of the system, but the overall performance and trade-offs have not been yet modelled. Furthermore, there is disagreement among experimental results that cannot be explained by the analytical tools available. In this work, a theoretical analysis of a generic DCDS readout system is presented, including key aspects such as the signal conditioning stage, the ADC resolution, the sampling frequency and the digital filter implementation. By using a time-domain noise model, the effect of the digital filter is properly modelled as a discrete-time process, thus avoiding the imprecision of continuous-time approximations that have been used so far. As a result, an accurate, closed-form expression for the signal-to-noise ratio at the output of the readout system is reached. This expression can be easily optimized in order to meet a set of specifications for a given CCD, thus providing a systematic design methodology for an optimal readout system. Simulated results are presented to validate the theory, obtained with both time- and frequency-domain noise generation models for completeness.

  20. Programmable Clock Waveform Generation for CCD Readout

    Energy Technology Data Exchange (ETDEWEB)

    Vicente, J. de; Castilla, J.; Martinez, G.; Marin, J.

    2006-07-01

    Charge transfer efficiency in CCDs is closely related to the clock waveform. In this paper, an experimental framework to explore different FPGA based clock waveform generator designs is described. Two alternative design approaches for controlling the rise/fall edge times and pulse width of the CCD clock signal have been implemented: level-control and time-control. Both approaches provide similar characteristics regarding the edge linearity and noise. Nevertheless, dissimilarities have been found with respect to the area and frequency range of application. Thus, while the time-control approach consumes less area, the level control approach provides a wider range of clock frequencies since it does not suffer capacitor discharge effect. (Author) 8 refs.

  1. Multiband CCD Image Compression for Space Camera with Large Field of View

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Space multiband CCD camera compression encoder requires low-complexity, high-robustness, and high-performance because of its captured images information being very precious and also because it is usually working on the satellite where the resources, such as power, memory, and processing capacity, are limited. However, the traditional compression approaches, such as JPEG2000, 3D transforms, and PCA, have the high-complexity. The Consultative Committee for Space Data Systems-Image Data Compression (CCSDS-IDC algorithm decreases the average PSNR by 2 dB compared with JPEG2000. In this paper, we proposed a low-complexity compression algorithm based on deep coupling algorithm among posttransform in wavelet domain, compressive sensing, and distributed source coding. In our algorithm, we integrate three low-complexity and high-performance approaches in a deeply coupled manner to remove the spatial redundant, spectral redundant, and bit information redundancy. Experimental results on multiband CCD images show that the proposed algorithm significantly outperforms the traditional approaches.

  2. Color balancing in CCD color cameras using analog signal processors made by Kodak

    Science.gov (United States)

    Kannegundla, Ram

    1995-03-01

    The green, red, and blue color filters used for CCD sensors generally have different responses. It is often necessary to balance these three colors for displaying a high-quality image on the monitor. The color filter arrays on sensors have different architectures. A CCD with standard G R G B pattern is considered for the present discussion. A simple method of separating the colors using CDS/H that is a part of KASPs (Analog Signal Processors made by Kodak) and using the gain control, which is also a part of KASPs for color balance, is presented. The colors are separated from the video output of sensor by using three KASPs, one each for green, red, and blue colors and by using alternate sample pulses for green and 1 in 4 pulses for red and blue. The separated colors gain is adjusted either automatically or manually and sent to the monitor for direct display in the analog mode or through an A/D converter digitally to the memory. This method of color balancing demands high-quality ASPs. Kodak has designed four different chips with varying levels of power consumption and speed for analog signal processing of video output of CCD sensors. The analog ASICs have been characterized for noise, clock feedthrough, acquisition time, linearity, variable gain, line rate clamp, black muxing, affect of temperature variations on chip performance, and droop. The ASP chips have met their design specifications.

  3. Systems approach to the design of the CCD sensors and camera electronics for the AIA and HMI instruments on solar dynamics observatory

    Science.gov (United States)

    Waltham, N.; Beardsley, S.; Clapp, M.; Lang, J.; Jerram, P.; Pool, P.; Auker, G.; Morris, D.; Duncan, D.

    2017-11-01

    Solar Dynamics Observatory (SDO) is imaging the Sun in many wavelengths near simultaneously and with a resolution ten times higher than the average high-definition television. In this paper we describe our innovative systems approach to the design of the CCD cameras for two of SDO's remote sensing instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI). Both instruments share use of a custom-designed 16 million pixel science-grade CCD and common camera readout electronics. A prime requirement was for the CCD to operate with significantly lower drive voltages than before, motivated by our wish to simplify the design of the camera readout electronics. Here, the challenge lies in the design of circuitry to drive the CCD's highly capacitive electrodes and to digitize its analogue video output signal with low noise and to high precision. The challenge is greatly exacerbated when forced to work with only fully space-qualified, radiation-tolerant components. We describe our systems approach to the design of the AIA and HMI CCD and camera electronics, and the engineering solutions that enabled us to comply with both mission and instrument science requirements.

  4. Sunlight exposure and sun sensitivity associated with disability progression in multiple sclerosis.

    Science.gov (United States)

    D'hooghe, M B; Haentjens, P; Nagels, G; Garmyn, M; De Keyser, J

    2012-04-01

    Sunlight and vitamin D have been inversely associated with the risk of multiple sclerosis (MS). We investigated sunlight exposure and sun sensitivity in relation to disability progression in MS. We conducted a survey among persons with MS, registered by the Flemish MS society, Belgium, and stratified data according to relapsing-onset and progressive-onset MS. We used Kaplan-Meier survival and Cox proportional hazard regression analyses with time to Expanded Disability Status Scale (EDSS) 6 as outcome measure. Hazard ratios for the time from onset and from birth were calculated for the potentially predictive variables, adjusting for age at onset, gender and immunomodulatory treatment. 704 (51.3%) of the 1372 respondents had reached EDSS 6. In relapsing-onset MS, respondents reporting equal or higher levels of sun exposure than persons of the same age in the last 10 years had a decreased risk of reaching EDSS 6. In progressive-onset MS, increased sun sensitivity was associated with an increased hazard of reaching EDSS 6. The association of higher sun exposure with a better outcome in relapsing-onset MS may be explained by either a protective effect or reverse causality. Mechanisms underlying sun sensitivity might influence progression in progressive-onset MS.

  5. Fabrication and characterization of one- and two-dimensional regular patterns produced employing multiple exposure holographic lithography

    DEFF Research Database (Denmark)

    Tamulevičius, S.; Jurkevičiute, A.; Armakavičius, N.

    2017-01-01

    In this paper we describe fabrication and characterization methods of two-dimensional periodic microstructures in photoresist with pitch of 1.2 urn and lattice constant 1.2-4.8 μm, formed using two-beam multiple exposure holographic lithography technique. The regular structures were recorded empl...

  6. Multiple Forms and Settings of Exposure to Violence and Values: Unique and Interactive Relationships With Antisocial Behavior in Adolescence.

    Science.gov (United States)

    Bacchini, Dario; Affuso, Gaetana; Aquilar, Serena

    2015-10-01

    The general purpose of this study was to investigate the relationships between multiple forms and settings of exposure to violence (ETV) as well as personal values and antisocial behavior (ASB) in adolescence. The association of ETV as witness or victim in different contexts (family, school, or neighborhood) and the association of the selected values of power, universalism, and conformity with ASB were analyzed. In addition, the role of ETV in moderating the relationship between values and ASB was tested. A total of 369 adolescents participated in the study. Hierarchical multiple regression analysis was performed. Results revealed that ASB was independently affected by exposure to family violence as a victim, exposure to school violence as a witness, exposure to neighborhood violence as a witness, and by all three selected values. The associations of ASB with universalism and conformity were negative. Conversely, the association of ASB with power was positive. One interaction had statistically significant effects. Results revealed that exposure to school violence as a witness moderates the relationship between universalism and ASB. The results highlight a high percentage of explained variance by ETV and values on ASB and suggest the importance of adopting a socio-ecological framework in interpreting adolescent behavior. © The Author(s) 2014.

  7. Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)

    International Nuclear Information System (INIS)

    Haugh, M; Schneider, M B

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  8. X-ray CCD image sensor with a thick depletion region

    International Nuclear Information System (INIS)

    Saito, Hirobumi; Watabe, Hiroshi.

    1984-01-01

    To develop a solid-state image sensor for high energy X-ray above 1 -- 2 keV, basic studies have been made on the CCD (charge coupled device) with a thick depletion region. A method of super-imposing a high DC bias voltage on low voltage signal pulses was newly proposed. The characteristics of both SCCD and BCCD were investigated, and their ability as X-ray sensors was compared. It was found that a depletion region of 60 μm thick was able to be obtained with ordinary doping density of 10 20 /m 3 , and that even thicker over 1 mm depletion region was able to be obtained with doping density of about 10 18 /m 3 , and a high bias voltage above 1 kV was able to be applied. It is suggested that the CCD image sensors for 8 keV or 24 keV X-ray can be realized since the absorption length of these X-ray in Si is about 60 μm and 1 mm, respectively. As for the characteristics other than the depletion thickness, the BCCD is preferable to SCCD for the present purpose because of lower noise and dark current. As for the transfer method, the frame-transfer method is recommended. (Aoki, K.)

  9. High-performance dual-speed CCD camera system for scientific imaging

    Science.gov (United States)

    Simpson, Raymond W.

    1996-03-01

    Traditionally, scientific camera systems were partitioned with a `camera head' containing the CCD and its support circuitry and a camera controller, which provided analog to digital conversion, timing, control, computer interfacing, and power. A new, unitized high performance scientific CCD camera with dual speed readout at 1 X 106 or 5 X 106 pixels per second, 12 bit digital gray scale, high performance thermoelectric cooling, and built in composite video output is described. This camera provides all digital, analog, and cooling functions in a single compact unit. The new system incorporates the A/C converter, timing, control and computer interfacing in the camera, with the power supply remaining a separate remote unit. A 100 Mbyte/second serial link transfers data over copper or fiber media to a variety of host computers, including Sun, SGI, SCSI, PCI, EISA, and Apple Macintosh. Having all the digital and analog functions in the camera made it possible to modify this system for the Woods Hole Oceanographic Institution for use on a remote controlled submersible vehicle. The oceanographic version achieves 16 bit dynamic range at 1.5 X 105 pixels/second, can be operated at depths of 3 kilometers, and transfers data to the surface via a real time fiber optic link.

  10. A luminescence imaging system based on a CCD camera

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Markey, B.G.

    1997-01-01

    Stimulated luminescence arising from naturally occurring minerals is likely to be spatially heterogeneous. Standard luminescence detection systems are unable to resolve this variability. Several research groups have attempted to use imaging photon detectors, or image intensifiers linked...... to photographic systems, in order to obtain spatially resolved data. However, the former option is extremely expensive and it is difficult to obtain quantitative data from the latter. This paper describes the use of a CCD camera for imaging both thermoluminescence and optically stimulated luminescence. The system...

  11. Fallow land mapping for better crop monitoring in Huang-Huai-Hai Plain using HJ-1 CCD data

    International Nuclear Information System (INIS)

    Zhang, Miao; Wu, Bingfang; Meng, Jihua; Dong, Taifeng; You, Xingzhi

    2014-01-01

    The prediction of grain production is essential for socio-economic development planning, guidance and control of macro cropping structure adjustment. Fallow areas should be identified each growing season which is critical for grain production prediction. This paper focuses on fallow arable land monitoring during summer grain season in the Huang-Huai-Hai Plain using China Environment Satellite HJ-1 CCD data. With the two satellites HJ-1A and HJ-1B, high temporal Normalized Difference Vegetation Index (NDVI) can be obtained. HJ-1 CCD data were acquired from early March to early June in 2010 over the Huang-Huai-Hai Plain. Multi-temporal HJ-1 CCD data were pre-processed and time series of NDVI were derived. An algorithm for separating cropped and fallow areas was developed based on three key periods of NDVI in early-March, mid-April and mid-May, 2010. The influence of fallow arable lands to yield estimation and crop condition monitoring over the Huang-Huai-Hai Plain were also investigated and analyzed. Preliminary results in this paper showed that HJ-1 CCD data are capable for fallow land monitoring. Information of fallow arable lands is an essential part of crop monitoring and it should be incorporated into crop monitoring systems. In the future, the fallow lands over autumn grain season should also be identified and information of fallow arable lands should be generated yearly in order to get more reliable production prediction

  12. First tests with fully depleted PN-CCD's

    International Nuclear Information System (INIS)

    Strueder, L.; Lutz, G.; Sterzik, M.; Holl, P.; Kemmer, J.; Prechtel, U.; Ziemann, T.; Rehak, P.

    1987-01-01

    We have fabricated 280 μm thick fully depletable pn CCD's on high resistivity silicon (/rho/ ∼ 2.5 kΩcm). Its operation is based on the semiconductor drift chamber principle proposed by Gatti and Rheak. They are designed as energy and position sensitive radiation detector for (minimum) ionizing particles and X-ray imaging. Two dimensional semiconductor device modeling demonstrates the basic charge transer mechanisms. Prototypes of the detectors have been tested in static and dynamic conditions. A preliminary charge transfer inefficiency was determined to 6 x 10/sup/minus/3/. The charge loss during the transfer is discussed and as a consequence we have developed an improved design for a second fabrication iteration which is now being produced. 4 refs., 15 figs

  13. Brayton Isotope Power System. Phase I. (Ground demonstration system) Configuration Control Document (CCD)

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration control document (CCD) defines the BIPS-GDS configuration. The GDS configuration is similar to a conceptual flight system design, referred to as the BIPS-FS, which is discussed in App. I. The BIPS is being developed by ERDA as a 500 to 2000 W(e), 7-y life, space power system utilizing a closed Brayton cycle gas turbine engine to convert thermal energy (from an isotope heat source) to electrical energy at a net efficiency exceeding 25 percent. The CCD relates to Phase I of an ERDA Program to qualify a dynamic system for launch in the early 1980's. Phase I is a 35-month effort to provide an FS conceptual design and GDS design, fabrication, and test. The baseline is a 7-year life, 450-pound, 4800 W(t), 1300 W(e) system which will use two multihundred watt (MHW) isotope heat sources being developed

  14. Near-infrared Raman spectroscopy using a diode laser and CCD detector for tissue diagnostics

    International Nuclear Information System (INIS)

    Gustafsson, U.

    1993-09-01

    This paper surveys the possibility to observe high-quality NIR Raman spectra of both fluorescent and non-fluorescent samples with the use of a diode laser, a fibre optic sample, a single spectrometer and a charge-coupled device (CCD) detector. A shifted excitation difference technique was implemented for removing the broad-band fluorescence emission from Raman spectra of the highly fluorescent samples. Raman spectra of 1.4-dioxane, toluene, rhodamine 6G, and HITCI in the 640 to 1840 cm -1 spectral region and 1.4-dioxane and toluene in the 400 to 3400 cm -1 spectral region have been recorded. The results open the field of sensitive tissue characterisation and the possibility of optical biopsy in vivo by using NIR Raman spectroscopy with fibre optic sampling, a single spectrometer, and a CCD detector

  15. New Cepheid distances to nearby galaxies based on BVRI CCD photometry. III - NGC 300

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, W.L.; Madore, B.F.; Hawley, S.L.; Horowitz, I.K.; Mould, J.; Navarrete, M.; Sallmen, S. (Carnegie Institution of Washington, Observatories, Pasadena, CA (United States) JPL, Pasadena, CA (United States) Lawrence Livermore National Laboratory, Livermore, CA (United States) California Institute of Technology, Pasadena (United States) Cerro Tololo Inter-American Observatory, La Serena (Chile) California, University, Berkeley (United States))

    1992-09-01

    A true distance modulus of (m - M) sub 0 = 26.66 +/- 0.10 mag (corresponding to 2.1 +/- 0.1 Mpc) has been determined for the Sculptor Group spiral galaxy NGC 300. New CCD data have been obtained for a sample of known Cepheids in this galaxy from which apparent distance moduli at B, V, R, and I wavelengths are determined. Combining the data available at different wavelenghts, and assuming a true distance modulus to the LMC of 18.5 mag, a true distance modulus is obtained for NGC 300, corrected for the effects of interstellar reddening. The availability of a new distance to NGC 300 brings to five the total number of galaxies with new CCD photometry of Cepheids, useful for calibration of the Hubble constant. 26 refs.

  16. Medium wave exposure characterisation using exposure quotients.

    Science.gov (United States)

    Paniagua, Jesús M; Rufo, Montaña; Jiménez, Antonio; Antolín, Alicia; Pinar, Iván

    2010-06-01

    One of the aspects considered in the International Commission on Non-Ionizing Radiation Protection guidelines is that, in situations of simultaneous exposure to fields of different frequencies, exposure quotients for thermal and electrical stimulation effects should be examined. The aim of the present work was to analyse the electromagnetic radiation levels and exposure quotients for exposure to multiple-frequency sources in the vicinity of medium wave radio broadcasting antennas. The measurements were made with a spectrum analyser and a monopole antenna. Kriging interpolation was used to prepare contour maps and to estimate the levels in the towns and villages of the zone. The results showed that the exposure quotient criterion based on electrical stimulation effects to be more stringent than those based on thermal effects or power density levels. Improvement of dosimetry evaluations requires the spectral components of the radiation to be quantified, followed by application of the criteria for exposure to multiple-frequency sources.

  17. Measurements of 161 Double Stars With a High-Speed CCD: The Winter/Spring 2017 Observing Program at Brilliant Sky Observatory, Part 2

    Science.gov (United States)

    Harshaw, Richard

    2018-04-01

    In the winter and spring of 2017, an aggressive observing program of measuring close double stars with speckle interferometry and CCD imaging was undertaken at Brilliant Sky Observatory, my observing site in Cave Creek, Arizona. A total of 596 stars were observed, 8 of which were rejected for various reasons, leaving 588 pairs. Of these, 427 were observed and measured with speckle interferometry, while the remaining 161 were measured with a CCD. This paper reports the results of the observations of the 161 CCD cases. A separate paper in this issue will report the speckle measurements of the 427 other pairs.

  18. BVI CCD photometry of 47 Tucanae

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.

    1987-01-01

    CCD BVI main-sequence photometry of 47 Tuc is presented, matched to the recent BVI isochrones of VandenBerg and Bell (1985). The main-sequence turnoffs are found to be at V = 17.60 + or - 0.1, B-V = 0.56 + or - 0.02; V-I = 0.68 + or - 0.02, and B-I = 1.24 + or - 0.02. The magnitude difference between the main-sequence turnoff and the horizontal branch is 3.55 + or - 0.15 for all three color indices. A consistent age for 47 Tuc of 17 Gyr and a consistent distance modulus of (m-M)v = 13.2 are obtained for all three indices, and an absolute magnitude of Mv = 0.85 is determined for the horizontal branch stars. The results also favor the adoption of (Fe/H) near -0.5 as the best abundance value for 47 Tuc. 38 references

  19. Neutral-beam performance analysis using a CCD camera

    International Nuclear Information System (INIS)

    Hill, D.N.; Allen, S.L.; Pincosy, P.A.

    1986-01-01

    We have developed an optical diagnostic system suitable for characterizing the performance of energetic neutral beams. An absolutely calibrated CCD video camera is used to view the neutral beam as it passes through a relatively high pressure (10 -5 Torr) region outside the neutralizer: collisional excitation of the fast deuterium atoms produces H/sub proportional to/ emission (lambda = 6561A) that is proportional to the local atomic current density, independent of the species mix of accelerated ions over the energy range 5 to 20 keV. Digital processing of the video signal provides profile and aiming information for beam optimization. 6 refs., 3 figs

  20. Opinion rating of comparison photographs of television pictures from CCD cameras under irradiation

    International Nuclear Information System (INIS)

    Reading, V.M.; Dumbreck, A.A.

    1991-01-01

    As part of the development of a general method of testing the effects of gamma radiation on CCD television cameras, this is a report of an experimental study on the optimisation of still photographic representation of video pictures recorded before and during camera irradiation. (author)

  1. Case study of atmospheric correction on CCD data of HJ-1 satellite based on 6S model

    International Nuclear Information System (INIS)

    Xue, Xiaoiuan; Meng, Oingyan; Xie, Yong; Sun, Zhangli; Wang, Chang; Zhao, Hang

    2014-01-01

    In this study, atmospheric radiative transfer model 6S was used to simulate the radioactive transfer process in the surface-atmosphere-sensor. An algorithm based on the look-up table (LUT) founded by 6S model was used to correct (HJ-1) CCD image pixel by pixel. Then, the effect of atmospheric correction on CCD data of HJ-1 satellite was analyzed in terms of the spectral curves and evaluated against the measured reflectance acquired during HJ-1B satellite overpass, finally, the normalized difference vegetation index (NDVI) before and after atmospheric correction were compared. The results showed: (1) Atmospheric correction on CCD data of HJ-1 satellite can reduce the ''increase'' effect of the atmosphere. (2) Apparent reflectance are higher than those of surface reflectance corrected by 6S model in band1∼band3, but they are lower in the near-infrared band; the surface reflectance values corrected agree with the measured reflectance values well. (3)The NDVI increases significantly after atmospheric correction, which indicates the atmospheric correction can highlight the vegetation information

  2. Exposure to Community Violence and Sexual Behaviors Among African American Youth: Testing Multiple Pathways.

    Science.gov (United States)

    Voisin, Dexter R; Hotton, Anna; Neilands, Torsten

    2018-01-01

    African American youth bear a disproportionate burden of sexually transmitted infections. A growing number of studies document that youth exposure to community violence and sexual behaviors are highly correlated. Despite such growing evidence, only a few studies have empirically tested conceptually driven pathways that may account for such relationships. This study seeks to address that gap by exploring multiple pathways linking exposure to community violence and youth sexual behaviors. Using an existing sample of 563 African American youth attending high school, we examined whether possible links between exposure to community violence and sexual activity, sexual risk behaviors were mediated by aggression, low student-teacher connectedness, and negative peer norms. Major findings indicated indirect relationships between exposures to community violence and both sexual activity and risky sex, mediated by aggression and negative peer norms with no significant differences based on gender or socioeconomic status. Overall findings also indicated a significant indirect effect of aggression to risky sex via negative peer norms and from community violence to risky peer norms via aggression. By illuminating ways that community violence, aggression, peer norms, and sexual behaviors are dynamically interrelated, these findings have significant implications for future research and intervention initiatives aimed at addressing the different pathways.

  3. The X-ray mirror telescope and the pn-CCD detector of CAST

    CERN Document Server

    Kuster, M; Englhauser, J; Franz, J; Friedrich, P; Hartmann, R; Kang, D; Kotthaus, R; Lutz, Gerhard; Moralez, J; Serber, W; Strüder, L

    2004-01-01

    The Cern Axion Solar Telescope - CAST - uses a prototype 9 Tesla LHC superconducting dipole magnet to search for a hypothetical pseudoscalar particle, the axion, which was proposed by theory in the 1980s to solve the strong CP problem and which could be a dark matter candidate. In CAST a strong magnetic field is used to convert the solar axions to detectable photons via inverse Primakoff effect. The resulting X-rays are thermally distributed in the energy range of 1-7 keV and can be observed with conventional X-ray detectors. The most sensitive detector system of CAST is a pn-CCD detector originally developed for XMM-Newton combined with a Wolter I type X-ray mirror system. The combination of a focusing X-ray optics and a state of the art pn-CCD detector which combines high quantum efficiency, good spacial and energy resolution, and low background improves the sensitivity of the CAST experiment such that for the first time the axion photon coupling constant can be probed beyond the best astrophysical constrai...

  4. A multi-nuclide approach to quantify long-term erosion rates and exposure history through multiple glacial-interglacial cycles

    DEFF Research Database (Denmark)

    Strunk, Astrid; Larsen, Nicolaj Krog; Knudsen, Mads Faurschou

    Cosmogenic nuclides are traditionally used to either determine the glaciation history or the denudation history of the most recent exposure period. A few studies use the cosmogenic nuclides to determine the cumulative exposure and burial durations of a sample. However, until now it has not been...... possible to resolve the complex pattern of exposure history under a fluctuating ice sheet. In this study, we quantify long-term erosion rates along with durations of multiple exposure periods in West Greenland by applying a novel Markov Chain Monte Carlo (MCMC) inversion approach to existing 10Be and 26Al....... The new MCMC approach allows us to constrain the most likely landscape history based on comparisons between simulated and measured cosmogenic nuclide concentrations. It is a fundamental assumption of the model that the exposure history at the site/location can be divided into two distinct regimes: i...

  5. Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    Science.gov (United States)

    Hunter, David M; Belev, George; Kasap, Safa; Yaffe, Martin J

    2012-02-01

    Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV), is the K-fluorescence reabsorption mechanism, wherein energy can be deposited in the detector at locations laterally displaced from the initial x-ray interaction site. This paper compares measured MTF changes above and below the Se K-edge of a CCD based a-Se x-ray detector with theoretical expectations. A prototype 25 μm sampling pitch (Nyquist frequency = 20 cycles mm(-1), 200 μm thick a-Se layer based x-ray detector, utilizing a specialized CCD readout device (200 × 400 area array), was used to make edge images with monochromatic x-rays above and below the K-edge of Se. A vacuum double crystal monochromator, exposed to polychromatic x-rays from a synchrotron, formed the monochromatic x-ray source. The monochromaticity of the x-rays was 99% or better. The presampling MTF was determined using the slanted edge method. The theory modeling the MTF performance of the detector includes the basic x-ray interaction physics in the a-Se layer as well as effects related to the operation of the CCD and charge trapping at a blocking layer present at the CCD/a-Se interface. The MTF performance of the prototype a-Se CCD was reduced from the theoretical value prescribed by the basic Se x-ray interaction physics, principally by the presence of a blocking layer. Nevertheless, the K-fluorescence reduction in the MTF was observed, approximately as predicted by theory. For the CCD prototype detector, at five cycles mm(-1), there was a 14% reduction of the MTF, from a value of 0.7 below the K-edge of Se, to 0.6 just above the K-edge. The MTF of an a-Se x-ray detector has been measured using

  6. Evaluation of the Accuracy of the Dark Frame Subtraction Method in CCD Image Processing

    National Research Council Canada - National Science Library

    Levesque, Martin P; Lelievre, Mario

    2007-01-01

    .... This method is frequently used for removing the image background gradient (a thermal artefact) in CCD images. This report demonstrates that this method may not be suitable for the detection of objects with very low signal-to-noise ratio...

  7. Integrated Assessment of Shallow-Aquifer Vulnerability to Multiple Contaminants and Drinking-Water Exposure Pathways in Holliston, Massachusetts

    Directory of Open Access Journals (Sweden)

    Birgit Claus Henn

    2017-12-01

    Full Text Available Half of U.S. drinking water comes from aquifers, and very shallow ones (<20 feet to water table are especially vulnerable to anthropogenic contamination. We present the case of Holliston, a Boston, Massachusetts suburb that draws its drinking water from very shallow aquifers, and where metals and solvents have been reported in groundwater. Community concerns focus on water discolored by naturally occurring manganese (Mn, despite reports stating regulatory aesthetic compliance. Epidemiologic studies suggest Mn is a potentially toxic element (PTE for children exposed by the drinking-water pathway at levels near the regulatory aesthetic level. We designed an integrated, community-based project: five sites were profiled for contaminant releases; service areas for wells were modeled; and the capture zone for one vulnerable well was estimated. Manganese, mercury, and trichloroethylene are among 20 contaminants of interest. Findings show that past and/or current exposures to multiple contaminants in drinking water are plausible, satisfying the criteria for complete exposure pathways. This case questions the adequacy of aquifer protection and monitoring regulations, and highlights the need for integrated assessment of multiple contaminants, associated exposures and health risks. It posits that community-researcher partnerships are essential for understanding and solving complex problems.

  8. The role of the potato (Solanum tuberosum) CCD8 gene in stolon and tuber development.

    Science.gov (United States)

    Pasare, Stefania A; Ducreux, Laurence J M; Morris, Wayne L; Campbell, Raymond; Sharma, Sanjeev K; Roumeliotis, Efstathios; Kohlen, Wouter; van der Krol, Sander; Bramley, Peter M; Roberts, Alison G; Fraser, Paul D; Taylor, Mark A

    2013-06-01

    · Strigolactones (SLs) are a class of phytohormones controlling shoot branching. In potato (Solanum tuberosum), tubers develop from underground stolons, diageotropic stems which originate from basal stem nodes. As the degree of stolon branching influences the number and size distribution of tubers, it was considered timely to investigate the effects of SL production on potato development and tuber life cycle. · Transgenic potato plants were generated in which the CAROTENOID CLEAVAGE DIOXYGENASE8 (CCD8) gene, key in the SL biosynthetic pathway, was silenced by RNA interference (RNAi). · The resulting CCD8-RNAi potato plants showed significantly more lateral and main branches than control plants, reduced stolon formation, together with a dwarfing phenotype and a lack of flowering in the most severely affected lines. New tubers were formed from sessile buds of the mother tubers. The apical buds of newly formed transgenic tubers grew out as shoots when exposed to light. In addition, we found that CCD8 transcript levels were rapidly downregulated in tuber buds by the application of sprout-inducing treatments. · These results suggest that SLs could have an effect, solely or in combination with other phytohormones, in the morphology of potato plants and also in controlling stolon development and maintaining tuber dormancy. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  9. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  10. Development of photoelectric balanced car based on the linear CCD sensor

    Directory of Open Access Journals (Sweden)

    Wang Feng

    2016-01-01

    Full Text Available The smart car is designed based on Freescale’s MC9S12XS128 and a linear CCD camera. The linear CCD collects the road information and sends it to MCU through the operational amplifier. The PID control algorithm, the proportional–integral–derivative control algorithm, is adopted synthetically to control the smart car. First, the smart car’s inclination and angular velocity are detect through the accelerometers and gyro sensors, then the PD control algorithm, the proportional–derivative control algorithm, is employed to make the smart car have the ability of two-wheeled self-balancing. Second, the speed of wheel obtained by the encoder is fed back to the MCU by way of pulse signal, then the PI control algorithm, the proportional–integral control algorithm, is employed to make the speed of smart car reach the set point in the shortest possible time and stabilize at the set point. Finally, the PD control algorithm is used to regulate the smart car’s turning angle to make the smart car respond quickly while the smart car is passing the curve path. The smart car can realize the self-balancing control of two wheels and track automatically the black and while lines to march.

  11. An LOD with improved breakdown voltage in full-frame CCD devices

    Science.gov (United States)

    Banghart, Edmund K.; Stevens, Eric G.; Doan, Hung Q.; Shepherd, John P.; Meisenzahl, Eric J.

    2005-02-01

    In full-frame image sensors, lateral overflow drain (LOD) structures are typically formed along the vertical CCD shift registers to provide a means for preventing charge blooming in the imager pixels. In a conventional LOD structure, the n-type LOD implant is made through the thin gate dielectric stack in the device active area and adjacent to the thick field oxidation that isolates the vertical CCD columns of the imager. In this paper, a novel LOD structure is described in which the n-type LOD impurities are placed directly under the field oxidation and are, therefore, electrically isolated from the gate electrodes. By reducing the electrical fields that cause breakdown at the silicon surface, this new structure permits a larger amount of n-type impurities to be implanted for the purpose of increasing the LOD conductivity. As a consequence of the improved conductance, the LOD width can be significantly reduced, enabling the design of higher resolution imaging arrays without sacrificing charge capacity in the pixels. Numerical simulations with MEDICI of the LOD leakage current are presented that identify the breakdown mechanism, while three-dimensional solutions to Poisson's equation are used to determine the charge capacity as a function of pixel dimension.

  12. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    International Nuclear Information System (INIS)

    Nohtomi, Akihiro; Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita; Shinsho, Kiyomitsu; Wakabayashi, Genichiro; Koba, Yusuke; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Ohga, Saiji

    2016-01-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.

  13. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    Energy Technology Data Exchange (ETDEWEB)

    Nohtomi, Akihiro, E-mail: nohtomi@hs.med.kyushu-u.ac.jp [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Shinsho, Kiyomitsu [Graduate School of Human Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-oku, Arakawa-ku, Tokyo 116-8551 (Japan); Wakabayashi, Genichiro [Atomic Energy Research Institute, Kinki University, 3-4-1 Kowakae, Higashiosaka-shi, Osaka 577-8502 (Japan); Koba, Yusuke [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko [Department of Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Ohga, Saiji [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2016-10-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.

  14. The long persistence of pyrrolizidine alkaloid-derived DNA adducts in vivo: kinetic study following single and multiple exposures in male ICR mice.

    Science.gov (United States)

    Zhu, Lin; Xue, Junyi; Xia, Qingsu; Fu, Peter P; Lin, Ge

    2017-02-01

    Pyrrolizidine alkaloid (PA)-containing plants are widespread in the world and the most common poisonous plants affecting livestock, wildlife, and humans. Our previous studies demonstrated that PA-derived DNA adducts can potentially be a common biological biomarker of PA-induced liver tumor formation. In order to validate the use of these PA-derived DNA adducts as a biomarker, it is necessary to understand the basic kinetics of the PA-derived DNA adducts formed in vivo. In this study, we studied the dose-dependent response and kinetics of PA-derived DNA adduct formation and removal in male ICR mice orally administered with a single dose (40 mg/kg) or multiple doses (10 mg/kg/day) of retrorsine, a representative carcinogenic PA. In the single-dose exposure, the PA-derived DNA adducts exhibited dose-dependent linearity and persisted for up to 4 weeks. The removal of the adducts following a single-dose exposure to retrorsine was biphasic with half-lives of 9 h (t 1/2α ) and 301 h (~12.5 days, t 1/2β ). In the 8-week multiple exposure study, a marked accumulation of PA-derived DNA adducts without attaining a steady state was observed. The removal of adducts after the multiple exposure also demonstrated a biphasic pattern but with much extended half-lives of 176 h (~7.33 days, t 1/2α ) and 1736 h (~72.3 days, t 1/2β ). The lifetime of PA-derived DNA adducts was more than 8 weeks following the multiple-dose treatment. The significant persistence of PA-derived DNA adducts in vivo supports their role in serving as a biomarker of PA exposure.

  15. Laser jamming experiment of varifocal colour CCD imaging system%变焦彩色CCD成像系统的激光干扰实验

    Institute of Scientific and Technical Information of China (English)

    汤伟; 王锐; 王挺峰; 郭劲

    2017-01-01

    Out-field laser jamming experiment of varifocal colour CCD imaging system irradiated by semiconductor laser was done.Laser jamming effects of colour CCD imaging system with different focal lengths were measured.Laser jamming model was set-up,and theoretical proving and analysis on experimental results were completed.Theorical and experimental results show that laser jamming effect of colour CCD imaging system irradiated by 750 nm laser is obvious,and CCD surface appears obvious light saturation and crosstalk phenomena.In the same initial laser irradiating conduction,laser power truncated by the aperture gradually decreases with increase of focal length f,and light saturation area on the CCD surface gradually increases.When focal length f of colour CCD imaging system is 17 mm,light saturation area on the CCD surface is 0.33 mm×0.29 mm.While focal length f of colour CCD imaging system increases to 120 mm,light saturation area on the CCD surface is 1.8 mm×1.2 mm.Simulation results are coincident with experimental results,and it proves laser jamming model is correct.The conclusions have a reference value for colour CCD in the practical application.%开展了变焦彩色CCD成像系统的激光外场干扰实验,测得了半导体激光(750 nm)对变焦距(17~187 mm)彩色CCD相机的干扰效果;同时利用典型的激光干扰CCD模型,完成了对实验结果的验证与理论分析.理论与实验结果表明:750 nm激光对彩色CCD成像系统的干扰效果明显,CCD靶面出现了明显的光饱和和串扰现象;在激光辐照条件相同情况下,光学系统焦距f越大,被光阑截断的激光就越少,到靶的激光功率密度就越高,CCD靶面的光饱和面积就越大;光学系统焦距f为17mm时,CCD靶面的光饱和面积为0.33 mm×0.29 mm,而当光学系统焦距f增大至120 mm时,CCD靶面的光饱和面积为1.8 mm×1.2 mm.仿真结果与实验结果基本一致,证明了理论模型的正确性.研究结果将对CCD器件的实际应用具有一定的指导意义.

  16. VXD3: The SLD vertex detector upgrade based on a 307 Mpixel CCD system

    International Nuclear Information System (INIS)

    1995-07-01

    The SLD Collaboration is building a new CCD vertex detector (VXD3) comprising 96 3.2 Mpixel CCDs of 13 cm 2 each for a total of 307 million pixels. This system is an upgrade of the Pioneering CCD vertex detector VXD2 which has operated in SLD since 1992. The CCDs of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three coordinates. The design and construction of VXD3 builds on three years of successful performance of VXD2. Significant improvements are achieved with VXD3 in impact parameters resolution (about a factor of two) and acceptance (∼20%) through optimized geometry and reduced material. New readout electronics have been developed for this system. This new vertex detector will be installed in late 1995 for the future runs of SLD

  17. Influence of Disease and Patient Characteristics on Daratumumab Exposure and Clinical Outcomes in Relapsed or Refractory Multiple Myeloma

    DEFF Research Database (Denmark)

    Yan, Xiaoyu; Clemens, Pamela L; Puchalski, Thomas

    2018-01-01

    OBJECTIVE: The aim of this study was to understand the influence of disease and patient characteristics on exposure to daratumumab, an immunoglobulin Gκ (IgGκ) monoclonal antibody, and clinical outcomes in relapsed or refractory multiple myeloma (MM). PATIENTS AND METHODS: Baseline myeloma type, ...

  18. SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, S; Uesaka, M [The University of Tokyo, Tokyo (Japan); Nishio, T; Tsuneda, M [Hiroshima University, Hiroshima (Japan); Matsushita, K [Rikkyo University, Tokyo (Japan); Kabuki, S [Tokai University, Isehara (Japan)

    2016-06-15

    Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

  19. Exposure to Multiple Pesticides and Risk of Non-Hodgkin Lymphoma in Men from Six Canadian Provinces

    Science.gov (United States)

    Hohenadel, Karin; Harris, Shelley A.; McLaughlin, John R.; Spinelli, John J.; Pahwa, Punam; Dosman, James A.; Demers, Paul A.; Blair, Aaron

    2011-01-01

    Non-Hodgkin lymphoma (NHL) has been linked to several agricultural exposures, including some commonly used pesticides. Although there is a significant body of literature examining the effects of exposure to individual pesticides on NHL, the impact of exposure to multiple pesticides or specific pesticide combinations has not been explored in depth. Data from a six-province Canadian case-control study conducted between 1991 and 1994 were analyzed to investigate the relationship between NHL, the total number of pesticides used and some common pesticide combinations. Cases (n = 513) were identified through hospital records and provincial cancer registries and controls (n = 1,506), frequency matched to cases by age and province of residence, were obtained through provincial health records, telephone listings, or voter lists. In multiple logistic regression analyses, risk of NHL increased with the number of pesticides used. Similar results were obtained in analyses restricted to herbicides, insecticides and several pesticide classes. Odds ratios increased further when only ‘potentially carcinogenic’ pesticides were considered (OR[one pesticide] = 1.30, 95% CI = 0.90–1.88; OR[two to four] = 1.54, CI = 1.11–2.12; OR[five or more] = 1.94, CI = 1.17–3.23). Elevated risks were also found among those reporting use of malathion in combination with several other pesticides. These analyses support and extend previous findings that the risk of NHL increases with the number of pesticides used and some pesticide combinations. PMID:21776232

  20. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  1. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, D.M., E-mail: dieter.schlosser@pnsensor.de [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Huth, M.; Hartmann, R. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Abboud, A.; Send, S. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Conka-Nurdan, T. [Türkisch-Deutsche Universität, Sakinkaya Cad. 86, Beykoz, 34820 Istanbul (Turkey); Shokr, M.; Pietsch, U. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Strüder, L. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany)

    2016-01-01

    By combining a low noise fully depleted pnCCD detector with a CsI(Tl) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In direct detection mode the pnCCD exhibits a relative energy resolution of 1% at 122 keV and spatial resolution of less than 75 µm, the pixel size of the pnCCD. In the indirect detection mode, i.e. conversion of the incoming X-rays in the scintillator, the measured energy resolution was about 9–13% at 122 keV, depending on the depth of interaction in the scintillator, while the position resolution, extracted with the help of simulations, was 30 µm only. We show simulated data for incident photons of 122 keV and compare the various interaction processes and relevant physical parameters to experimental results obtained with a radioactive {sup 57}Co source. - Highlights: • Position and energy resolving pnCCD+CsI(Tl) detector for energies from 1-150 keV • Detection in the pnCCD (122keV): 1% energy and <75µm spatial resolution • Detection in the scintillator (122keV): 9-12% energy and ~30µm spatial resolution.

  2. Macromolecular crystallographic results obtained using a 2048x2048 CCD detector at CHESS

    International Nuclear Information System (INIS)

    Thiel, D.J.; Ealick, S.E.; Tate, M.W.; Gruner, S.M.; Eikenberry, E.F.

    1996-01-01

    We present results of macromolecular crystallographic experiments performed at the Cornell High Energy Synchrotron Source (CHESS) with a new CCD-based detector. This detector, installed in January 1995, complements a 1024x1024 CCD detector that has been in continuous operation at CHESS since December 1993. The new detector is based on a 4-port, 2048x2048 pixel CCD that is directly coupled to a Gd 2 O 2 S:Tb phosphor by a 3:1 tapered fiber optic. The active area of the phosphor is a square 82 mm on an edge. The readout time is 7 seconds. In the standard mode of operation, the pixel size at the active area is 41 μm on the edge leading to the capability of resolving approximately 200 orders of diffraction across the detector face. The detector also operates in a 1024x1024 mode in which the pixel size is electronically increased by a factor of 4 in area resulting in smaller data files and faster detector readout but at the expense of spatial resolution. Most of the data that has been collected by this detector has been collected in this mode. Dozens of data sets have been collected by many experimenters using this detector at CHESS during the four month period from its installation until the start of the six-month down period of the storage ring. The capabilities of the detector will be illustrated with results from various crystallographic measurements including experiments in which the recorded diffraction patterns extend in resolution as far as 1 A. The results demonstrate that this detector is capable of collecting data of quality at least equal to that of imaging plates but, in many circumstances, with much greater beamline efficiency. copyright 1996 American Institute of Physics

  3. Fotometría de imágenes CCD insuficientemente muestreadas

    Science.gov (United States)

    Ostrov, P. G.

    Se enfrenta el problema de la fotometría de imágenes CCD con una escala inadecuada (fwhm menor o igual que el tamaño de un pixel) y psf fuertemente variable con la posición. Se analiza, en particular, la aplicabilidad de una táctica propuesta por Massey, consistente en eliminar las vecinas débiles (utilizando una psf rudimentaria) para luego efectuar una fotometría de apertura sobre las estrellas brillantes. Se determina, mediante experimentos numéricos, la precisión alcanzada mediante esta técnica.

  4. DOUBLE STARS IN THE USNO CCD ASTROGRAPHIC CATALOG

    Energy Technology Data Exchange (ETDEWEB)

    Hartkopf, William I.; Mason, Brian D.; Finch, Charlie T.; Zacharias, Norbert; Wycoff, Gary L.; Hsu, Danley, E-mail: wih@usno.navy.mil, E-mail: bdm@usno.navy.mil, E-mail: finch@usno.navy.mil, E-mail: nz@usno.navy.mil [US Naval Observatory, Washington, DC 20392 (United States)

    2013-10-01

    The newly completed Fourth USNO CCD Astrographic Catalog (UCAC4) has proven to be a rich source of double star astrometry and photometry. Following initial comparisons of UCAC4 results against those obtained by speckle interferometry, the UCAC4 catalog was matched against known double stars in the Washington Double Star Catalog in order to provide additional differential astrometry and photometry for these pairs. Matches to 58,131 pairs yielded 61,895 astrometric and 68,935 photometric measurements. Finally, a search for possible new common proper motion (CPM) pairs was made using new UCAC4 proper motion data; this resulted in 4755 new potential CPM doubles (and an additional 27,718 astrometric and photometric measures from UCAC and other sources)

  5. Temporal Assessment of the Impact of Exposure to Cow Feces in Two Watersheds by Multiple Host-Specific PCR Assays

    Science.gov (United States)

    Exposure to feces in two watersheds with different management histories was assessed by tracking cattle feces bacterial populations using multiple host-specific PCR assays. In addition, environmental factors affecting the occurrence of these markers were identified. Each assay wa...

  6. MS Sunshine Study: Sun Exposure But Not Vitamin D Is Associated with Multiple Sclerosis Risk in Blacks and Hispanics.

    Science.gov (United States)

    Langer-Gould, Annette; Lucas, Robyn; Xiang, Anny H; Chen, Lie H; Wu, Jun; Gonzalez, Edlin; Haraszti, Samantha; Smith, Jessica B; Quach, Hong; Barcellos, Lisa F

    2018-02-27

    Multiple sclerosis (MS) incidence and serum 25-hydroxyvitamin D (25OHD) levels vary by race/ethnicity. We examined the consistency of beneficial effects of 25OHD and/or sun exposure for MS risk across multiple racial/ethnic groups. We recruited incident MS cases and controls (blacks 116 cases/131 controls; Hispanics 183/197; whites 247/267) from the membership of Kaiser Permanente Southern California into the MS Sunshine Study to simultaneously examine sun exposure and 25OHD, accounting for genetic ancestry and other factors. Higher lifetime ultraviolet radiation exposure (a rigorous measure of sun exposure) was associated with a lower risk of MS independent of serum 25OHD levels in blacks (adjusted OR = 0.53, 95% CI = 0.31-0.83; p = 0.007) and whites (OR = 0.68, 95% CI = 0.48-0.94; p = 0.020) with a similar magnitude of effect that did not reach statistical significance in Hispanics (OR = 0.66, 95% CI = 0.42-1.04; p = 0.071). Higher serum 25OHD levels were associated with a lower risk of MS only in whites. No association was found in Hispanics or blacks regardless of how 25OHD was modeled. Lifetime sun exposure appears to reduce the risk of MS regardless of race/ethnicity. In contrast, serum 25OHD levels are not associated with MS risk in blacks or Hispanics. Our findings challenge the biological plausibility of vitamin D deficiency as causal for MS and call into question the targeting of specific serum 25OHD levels to achieve health benefits, particularly in blacks and Hispanics.

  7. 基于线性 CCD 的智能车路径提取与寻迹%Path extraction and tracing of smart car based on linear CCD

    Institute of Scientific and Technical Information of China (English)

    白晋龙

    2016-01-01

    Extraction track information and tracing based on linear CCD is a key link in the development of smart car . This paper first introduced the linear CCD with matters should be noted in the use of the process .Then introduced the black and white border extraction algorithm .The effect of dirt or shadow on boundary extraction is eliminated by using corrosion method .Three kinds of track search methods are proposed .The methods are the center line tracing method , single track tracing method and track prediction method .The advantages and disadvantages of the three methods are compared in detail .Finally ,the author makes use of the single track search method to complete the production of intelligent vehicle ,the use of the limited resources of the Carle microcontroller to ensure that the race is not out of the runw ay .%基于线性CCD提取赛道信息和按照赛道信息控制智能车寻迹是光电组智能车制作中的关键环节。本文首先介绍了线性CCD ,以及使用过程中应该注意的事项,然后介绍了黑白边界提取算法,采用腐蚀算法消除了赛道上污垢或阴影对边界提取的影响,提出了3种赛道寻迹方法,分别为中心线寻迹法、单边寻迹法、赛道预估法,详细比较了3种方法的优缺点,单边寻迹法不仅适用于各种赛道情况,而且处理信息少,占用CPU空间小。最后利用单边寻迹法完成智能车制作,使用飞思卡尔单片机有限的资源保证在不冲出跑道的前提下完成了比赛。

  8. [NDVI difference rate recognition model of deciduous broad-leaved forest based on HJ-CCD remote sensing data].

    Science.gov (United States)

    Wang, Yan; Tian, Qing-Jiu; Huang, Yan; Wei, Hong-Wei

    2013-04-01

    The present paper takes Chuzhou in Anhui Province as the research area, and deciduous broad-leaved forest as the research object. Then it constructs the recognition model about deciduous broad-leaved forest was constructed using NDVI difference rate between leaf expansion and flowering and fruit-bearing, and the model was applied to HJ-CCD remote sensing image on April 1, 2012 and May 4, 2012. At last, the spatial distribution map of deciduous broad-leaved forest was extracted effectively, and the results of extraction were verified and evaluated. The result shows the validity of NDVI difference rate extraction method proposed in this paper and also verifies the applicability of using HJ-CCD data for vegetation classification and recognition.

  9. Pengembangan Metoda Deteksi Rintangan untuk Traktor tanpa Awak Menggunakan Kamera CCD

    Directory of Open Access Journals (Sweden)

    Usman Ahmad

    2012-04-01

    Full Text Available For unmanned tractor guided by global positioning system, ability for eluding obstacles such as trees, big stone, cavity, bund, people, and other objects in the work area is very important in order not to stop the operation.Surrounding detection system using CCD camera makes it possible for unmanned tractor to detect obstacles in front of it realtime. However, with so many different objects that may captured by the camera, it will need a lot of image processing steps that takes a lot of time so it is no longer suitable for realtime detection in application. The proposed research is aimed to develop a simpler obstacle detection method by adding a red laser pointer to the CCD camera used to capture scene in front of the tractor. The red laser light that reflected by an obstacle gives an important information in the image, and the distance of the obstacle could be calculated based on phytagoras theory. The results showed that all obstacles with 1 m distance, 80% obstacles with 2 m distance, and 40% obstacles with 3 m distance could be detected. Obstacles with more than 3 m distances could not be detected due to weak laser light for the distances. The accuracy of distance prediction for all situation is 67.5%, which is still need improvements.

  10. Characterization of the multiple drug resistance phenotype expressed by tumour cells following in vitro exposure to fractionated X-irradiation

    International Nuclear Information System (INIS)

    Hill, B.T.; McClean, S.; Hosking, L.; Shellard, S.; Dempke, W.; Whelan, R.

    1992-01-01

    The major clinical problem of the emergence of drug resistant tumor cell populations is recognized in patients previously treated with antitumor drugs and with radiotherapy. It is proposed that, although radiation-induced vascular fibrosis may limit drug delivery to the tumor, exposure to radiation may 'induce' or 'select for' drug resistance. This hypothesis was examined by establishing in vitro model systems to investigate the resistance phenotype of tumor cells following exposure to X-rays. Characteristically tumor cells surviving exposure to a series of fractions of X-irradiation are shown to have consistently expressed resistance to multiple drugs, including the Vinca alkaloids and the epipodophyllotoxins. Currently this research is aimed at determining whether distinctive resistance mechanisms operate depending on whether resistance results following drug or X-ray exposure. Initial results indicate that whilst some common mechanisms operate, drug resistant tumor cells identified following exposure to X-irradiation appear to exhibit a novel multidrug resistance phenotype. (author). 13 refs., 1 tab

  11. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer

    Science.gov (United States)

    Yin, Yu; Cui, Yongsheng; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The Raman spectrum technology is widely used for it can identify various types of molecular structure and material. The portable Raman spectrometer has become a hot direction of the spectrometer development nowadays for its convenience in handheld operation and real-time detection which is superior to traditional Raman spectrometer with heavy weight and bulky size. But there is still a gap for its measurement sensitivity between portable and traditional devices. However, portable Raman Spectrometer with Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) technology can enhance the Raman signal significantly by several orders of magnitude, giving consideration in both measurement sensitivity and mobility. This paper proposed a design and implementation of driver and digital circuit for high accuracy CCD sensor, which is core part of portable spectrometer. The main target of the whole design is to reduce the dark current generation rate and increase signal sensitivity during the long integration time, and in the weak signal environment. In this case, we use back-thinned CCD image sensor from Hamamatsu Corporation with high sensitivity, low noise and large dynamic range. In order to maximize this CCD sensor's performance and minimize the whole size of the device simultaneously to achieve the project indicators, we delicately designed a peripheral circuit for the CCD sensor. The design is mainly composed with multi-voltage circuit, sequential generation circuit, driving circuit and A/D transition parts. As the most important power supply circuit, the multi-voltage circuits with 12 independent voltages are designed with reference power supply IC and set to specified voltage value by the amplifier making up the low-pass filter, which allows the user to obtain a highly stable and accurate voltage with low noise. What's more, to make our design easy to debug, CPLD is selected to generate sequential signal. The A/D converter chip consists of a correlated

  12. Analysis of total visual and ccd v-broadband observation of comet c/1995 o1 (hale-bopp): 1995-2003

    Science.gov (United States)

    de Almeida, A. A.; Boczko, R.; Lopes, A. R.; Sanzovo, G. C.

    The wealth of available information on total visual magnitudes and broadband-V CCD observations of the exceptionally bright Comet C/1995 O1 (Hale-Bopp) proved to be an excellent opportunity to test the Semi-Empirical Method of Visual Magnitudes (de Almeida, Singh & Huebner, 1997) for very bright comets. The main objective is to extend the method to include total visual magnitude observations obtained with CCD detector and V filter in our analysis of total visual magnitudes and obtain a single light curve. We compare the CCD V-broadband careful observations of Liller (1997) by plotting then together with the total visual magnitude observations from experienced visual observers found in the International Comet Quarterly (ICQ) archive. We find a nice agreement despite of the fact that CCDs and V filter passbands detect systematically more coma than visual observers, since they have different responses to C2, which is the main emission from the coma, and consequently they should be used with larger apperture diameters. A data set of ˜400 CCD selected observations covering about the same 5 years time span of the ˜12,000 ICQ total visual magnitude observations were used in the analysis. A least-squares fit to the values yielded a relation for water production rates vs heliocentric distances for the pre- and post-perihelion phases and are converted into gas production rates (in g/s) released by the nucleus. The dimension of the nucleus as well as its effective active area is determined and compared to other works.

  13. A CCD camera probe for a superconducting cyclotron

    International Nuclear Information System (INIS)

    Marti, F.; Blue, R.; Kuchar, J.; Nolen, J.A.; Sherrill, B.; Yurkon, J.

    1991-01-01

    The traditional internal beam probes in cyclotrons have consisted of a differential element, a wire or thin strip, and a main probe with several fingers to determine the vertical distribution of the beam. The resolution of these probes is limited, especially in the vertical direction. The authors have developed a probe for their K1200 superconducting cyclotron based on a CCD TV camera that works in a 6 T magnetic field. The camera looks at the beam spot on a scintillating screen. The TV image is processed by a frame grabber that digitizes and displays the image in pseudocolor in real time. This probe has much better resolution than traditional probes. They can see beams with total currents as low as 0.1 pA, with position resolution of about 0.05 mm

  14. A USB 2.0 computer interface for the UCO/Lick CCD cameras

    Science.gov (United States)

    Wei, Mingzhi; Stover, Richard J.

    2004-09-01

    The new UCO/Lick Observatory CCD camera uses a 200 MHz fiber optic cable to transmit image data and an RS232 serial line for low speed bidirectional command and control. Increasingly RS232 is a legacy interface supported on fewer computers. The fiber optic cable requires either a custom interface board that is plugged into the mainboard of the image acquisition computer to accept the fiber directly or an interface converter that translates the fiber data onto a widely used standard interface. We present here a simple USB 2.0 interface for the UCO/Lick camera. A single USB cable connects to the image acquisition computer and the camera's RS232 serial and fiber optic cables plug into the USB interface. Since most computers now support USB 2.0 the Lick interface makes it possible to use the camera on essentially any modern computer that has the supporting software. No hardware modifications or additions to the computer are needed. The necessary device driver software has been written for the Linux operating system which is now widely used at Lick Observatory. The complete data acquisition software for the Lick CCD camera is running on a variety of PC style computers as well as an HP laptop.

  15. Scan-free grazing emission XRF measurements in the laboratory using a CCD

    International Nuclear Information System (INIS)

    Szwedowski, Veronika; Baumann, Jonas; Mantouvalou, Ioanna; Bauer, Leona; Malzer, Wolfgang; Kanngiesser, Birgit

    2017-01-01

    The rapid development of new classes of nanomaterials calls for easy access methods in order to quantify properties essential for their functionality, e.g., interdiffusion of elements at interfaces, or elemental dopant, or depth profiles. Non-destructive methods, like X-ray fluorescence (XRF), are of special interest, for preserving materials and offering the possibility to incorporate the analysis in a production process. In-depth XRF methods for the characterization of nanomaterials are up until now limited to synchrotron radiation facilities. A novel scan-free grazing emission XRF (GEXRF) setup is presented utilizing conventional and low-cost hardware, acting as a transfer of a synchrotron method into the laboratory. A chromium target X-ray tube with a polycapillary lens is used as X-ray source and a conventional CCD as the 2D energy-dispersive detector. To confirm the feasibility of the described setup a nanometer-layered titanium-aluminium sample is measured. An energy-dispersive spectrum is obtained in single-photon-counting-mode from the CCD measurements and first GEXRF profiles generated. A semi-quantitative evaluation of this setup is implemented by comparing the measured results with simulations, allowing conclusions about the investigated samples' elemental, compositional, and structural layer-by-layer characteristics. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. MS Sunshine Study: Sun Exposure But Not Vitamin D Is Associated with Multiple Sclerosis Risk in Blacks and Hispanics

    Directory of Open Access Journals (Sweden)

    Annette Langer-Gould

    2018-02-01

    Full Text Available Multiple sclerosis (MS incidence and serum 25-hydroxyvitamin D (25OHD levels vary by race/ethnicity. We examined the consistency of beneficial effects of 25OHD and/or sun exposure for MS risk across multiple racial/ethnic groups. We recruited incident MS cases and controls (blacks 116 cases/131 controls; Hispanics 183/197; whites 247/267 from the membership of Kaiser Permanente Southern California into the MS Sunshine Study to simultaneously examine sun exposure and 25OHD, accounting for genetic ancestry and other factors. Higher lifetime ultraviolet radiation exposure (a rigorous measure of sun exposure was associated with a lower risk of MS independent of serum 25OHD levels in blacks (adjusted OR = 0.53, 95% CI = 0.31–0.83; p = 0.007 and whites (OR = 0.68, 95% CI = 0.48–0.94; p = 0.020 with a similar magnitude of effect that did not reach statistical significance in Hispanics (OR = 0.66, 95% CI = 0.42–1.04; p = 0.071. Higher serum 25OHD levels were associated with a lower risk of MS only in whites. No association was found in Hispanics or blacks regardless of how 25OHD was modeled. Lifetime sun exposure appears to reduce the risk of MS regardless of race/ethnicity. In contrast, serum 25OHD levels are not associated with MS risk in blacks or Hispanics. Our findings challenge the biological plausibility of vitamin D deficiency as causal for MS and call into question the targeting of specific serum 25OHD levels to achieve health benefits, particularly in blacks and Hispanics.

  17. A FORTRAN realization of the block adjustment of CCD frames

    Science.gov (United States)

    Yu, Yong; Tang, Zhenghong; Li, Jinling; Zhao, Ming

    A FORTRAN version realization of the block adjustment (BA) of overlapping CCD frames is developed. The flowchart is introduced including (a) data collection, (b) preprocessing, and (c) BA and object positioning. The subroutines and their functions are also demonstrated. The program package is tested by simulated data with/without the application of white noises. It is also preliminarily applied to the reduction of optical positions of four extragalactic radio sources. The results show that because of the increase in the sky coverage and number of reference stars, the precision of deducted positions is improved compared with single plate adjustment.

  18. Análise de mapas de represas publicados na web usando imagens orbitais CCD/CBERS no estado de Minas Gerais Analysis of dams maps published on the web by using orbital CCD/CBERS images in Minas Gerais State, Brazil

    Directory of Open Access Journals (Sweden)

    Elizabeth Ferreira

    2010-02-01

    Full Text Available Neste trabalho, bancos de dados públicos e gratuitos disponíveis na World Wide Web (WEB foram utilizados para avaliar as áreas das superfícies dos espelhos d'água das represas de Furnas e do Funil, no Estado de Minas Gerais. O objetivo foi comparar as informações obtidas nos bancos da WEB com os valores das áreas calculadas a partir de imagens do sensor CCD a bordo dos satélites CBERS2 e CBERS2B. A área da represa de Furnas obtida a partir das imagens CCD/CBERS2B, ano 2008, foi de 1.138 km², mas nos bancos de dados consultados esta área estava entre 1.182 e 1.503 km². A represa do Funil, construída em 2003, com superfície de espelho d'água de 29,37 km² e uma ilha com área de 1,93 km² não aparecem nos bancos Atlas, Geominas, IGAM e IBGE. Os resultados mostraram algumas discrepâncias nos bancos de dados publicados na WEB, tais como diferenças em áreas e supressão ou extrapolação de limites do espelho d'água. Concluiu-se que, até o momento, os responsáveis por algumas publicações de bancos de dados no Estado de Minas Gerais não tiveram rigor suficiente com as atualizações. As imagens CCD/CBERS, que também são dados públicos disponíveis na WEB, mostraram ser produtos adequados para verificar, atualizar e melhorar as informações publicadas.In this work some public databases from the World Wide Web (WEB were used to find the area of the Furnas and Funil Dams in Minas Gerais State. The purpose of this work was to compare the WEB public databases values and the real values obtained from the CCD camera images on board CBERS2 and CBERS2B satellites. The Furnas Dam area obtained from CCD/ CBERS2B images, in 2008, was 1.138 km², but in the consulted databases this area ranged from 1.182 to 1.503 km². The dam of the Funil, built in 2003, with a water surface of 29.37 km² and an island with 1.93 km² area, did not appear in Atlas, Geominas, IGAM and IBGE databases. The results revealed some problems in the WEB public

  19. Sequential Exposure of Bortezomib and Vorinostat is Synergistic in Multiple Myeloma Cells

    Science.gov (United States)

    Nanavati, Charvi; Mager, Donald E.

    2018-01-01

    Purpose To examine the combination of bortezomib and vorinostat in multiple myeloma cells (U266) and xenografts, and to assess the nature of their potential interactions with semi-mechanistic pharmacodynamic models and biomarkers. Methods U266 proliferation was examined for a range of bortezomib and vorinostat exposure times and concentrations (alone and in combination). A non-competitive interaction model was used with interaction parameters that reflect the nature of drug interactions after simultaneous and sequential exposures. p21 and cleaved PARP were measured using immunoblotting to assess critical biomarker dynamics. For xenografts, data were extracted from literature and modeled with a PK/PD model with an interaction parameter. Results Estimated model parameters for simultaneous in vitro and xenograft treatments suggested additive drug effects. The sequence of bortezomib preincubation for 24 hours, followed by vorinostat for 24 hours, resulted in an estimated interaction term significantly less than 1, suggesting synergistic effects. p21 and cleaved PARP were also up-regulated the most in this sequence. Conclusions Semi-mechanistic pharmacodynamic modeling suggests synergistic pharmacodynamic interactions for the sequential administration of bortezomib followed by vorinostat. Increased p21 and cleaved PARP expression can potentially explain mechanisms of their enhanced effects, which require further PK/PD systems analysis to suggest an optimal dosing regimen. PMID:28101809

  20. High-dynamic-range microscope imaging based on exposure bracketing in full-field optical coherence tomography.

    Science.gov (United States)

    Leong-Hoi, Audrey; Montgomery, Paul C; Serio, Bruno; Twardowski, Patrice; Uhring, Wilfried

    2016-04-01

    By applying the proposed high-dynamic-range (HDR) technique based on exposure bracketing, we demonstrate a meaningful reduction in the spatial noise in image frames acquired with a CCD camera so as to improve the fringe contrast in full-field optical coherence tomography (FF-OCT). This new signal processing method thus allows improved probing within transparent or semitransparent samples. The proposed method is demonstrated on 3 μm thick transparent polymer films of Mylar, which, due to their transparency, produce low contrast fringe patterns in white-light interference microscopy. High-resolution tomographic analysis is performed using the technique. After performing appropriate signal processing, resulting XZ sections are observed. Submicrometer-sized defects can be lost in the noise that is present in the CCD images. With the proposed method, we show that by increasing the signal-to-noise ratio of the images, submicrometer-sized defect structures can thus be detected.

  1. Exposure to multiple cholinergic pesticides impairs olfactory learning and memory in honeybees.

    Science.gov (United States)

    Williamson, Sally M; Wright, Geraldine A

    2013-05-15

    Pesticides are important agricultural tools often used in combination to avoid resistance in target pest species, but there is growing concern that their widespread use contributes to the decline of pollinator populations. Pollinators perform sophisticated behaviours while foraging that require them to learn and remember floral traits associated with food, but we know relatively little about the way that combined exposure to multiple pesticides affects neural function and behaviour. The experiments reported here show that prolonged exposure to field-realistic concentrations of the neonicotinoid imidacloprid and the organophosphate acetylcholinesterase inhibitor coumaphos and their combination impairs olfactory learning and memory formation in the honeybee. Using a method for classical conditioning of proboscis extension, honeybees were trained in either a massed or spaced conditioning protocol to examine how these pesticides affected performance during learning and short- and long-term memory tasks. We found that bees exposed to imidacloprid, coumaphos, or a combination of these compounds, were less likely to express conditioned proboscis extension towards an odor associated with reward. Bees exposed to imidacloprid were less likely to form a long-term memory, whereas bees exposed to coumaphos were only less likely to respond during the short-term memory test after massed conditioning. Imidacloprid, coumaphos and a combination of the two compounds impaired the bees' ability to differentiate the conditioned odour from a novel odour during the memory test. Our results demonstrate that exposure to sublethal doses of combined cholinergic pesticides significantly impairs important behaviours involved in foraging, implying that pollinator population decline could be the result of a failure of neural function of bees exposed to pesticides in agricultural landscapes.

  2. A new CCD-camera neutron radiography detector at the Atominstitute of the Austrian Universities

    International Nuclear Information System (INIS)

    Koerner, S.; Boeck, H.; Rauch, H.; Lehmann, E.

    1999-01-01

    Neutron radiography provides a very efficient tool for non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two dimensional imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. At the Atominstitute of the Austrian Universities neutron radiographic examinations have been carried out for more than 35 years, mainly with detectors consisting of X-ray films and a Gd- converter enclosed in a vacuum cassette. Presently a neutron tomography set-up is under development. For high quality 3D image reconstruction, about 200 digitized neutron transmission images from different angles of the object are necessary. Therefore the first step was the design of an adequate electronic neutron radiography imaging device. The requirements for a detector suitable for neutron tomography are: exact and reproducible positioning, easy handling, high spatial resolution and dynamic range, high efficiency and a good linearity. The key components of the detector system selected on the basis of the requirements consist of a neutron sensitive scintillator screen, a cooled slow scan CCD camera and a mirror to reflect the light emitted by the scintillator to the CCD camera. The whole assembly is placed in a light tight enclosure. In this paper the strategy of the selection of the individual detector components is described. Comparisons on the influence of the use of different components on the properties of the whole position sensitive imaging device are demonstrated. Finally the new CCD camera neutron radiography detector of the Atominstitute is presented and first results of test measurements performed at the neutron radiography facility NEUTRA at the continuous spallation source SINQ at Paul Scherrer Institute are shown.(author)

  3. Insights into the formation of carlactone from in-depth analysis of the CCD8-catalyzed reactions

    KAUST Repository

    Bruno, Mark; Vermathen, Martina; Alder, Adrian; Wü st, Florian; Schaub, Patrick; van der Steen, Rob; Beyer, Peter; Ghisla, Sandro; Al-Babili, Salim

    2017-01-01

    Strigolactones (SLs) are a new class of phytohormones synthesized from carotenoids via carlactone. The complex structure of carlactone is not easily deducible from its precursor, a cis-configured β-carotene cleavage product, and is thus formed via a poorly understood series of reactions and molecular rearrangements, all catalyzed by only one enzyme, the carotenoid cleavage dioxygenase 8 (CCD8). Moreover, the reactions leading to carlactone are expected to form a second, yet unidentified product. In this study, we used (13) C and (18) O-labelling to shed light on the reactions catalyzed by CCD8. The characterization of the resulting carlactone by LC-MS and NMR, and the identification of the assumed, less accessible second product allowed us to formulate a minimal reaction mechanism for carlactone generation. This article is protected by copyright. All rights reserved.

  4. Insights into the formation of carlactone from in-depth analysis of the CCD8-catalyzed reactions

    KAUST Repository

    Bruno, Mark

    2017-02-10

    Strigolactones (SLs) are a new class of phytohormones synthesized from carotenoids via carlactone. The complex structure of carlactone is not easily deducible from its precursor, a cis-configured β-carotene cleavage product, and is thus formed via a poorly understood series of reactions and molecular rearrangements, all catalyzed by only one enzyme, the carotenoid cleavage dioxygenase 8 (CCD8). Moreover, the reactions leading to carlactone are expected to form a second, yet unidentified product. In this study, we used (13) C and (18) O-labelling to shed light on the reactions catalyzed by CCD8. The characterization of the resulting carlactone by LC-MS and NMR, and the identification of the assumed, less accessible second product allowed us to formulate a minimal reaction mechanism for carlactone generation. This article is protected by copyright. All rights reserved.

  5. Hierarchical sampling of multiple strata: an innovative technique in exposure characterization

    International Nuclear Information System (INIS)

    Ericson, J.E.; Gonzalez, Elisabeth J.

    2003-01-01

    Sampling of multiple strata, or hierarchical sampling of various exposure sources and activity areas, has been tested and is suggested as a method to sample (or to locate) areas with a high prevalence of elevated blood lead in children. Hierarchical sampling was devised to supplement traditional soil lead sampling of a single stratum, either residential or fixed point source, using a multistep strategy. Blood lead (n=1141) and soil lead (n=378) data collected under the USEPA/UCI Tijuana Lead Project (1996-1999) were analyzed to evaluate the usefulness of sampling soil lead from background sites, schools and parks, point sources, and residences. Results revealed that industrial emissions have been a contributing factor to soil lead contamination in Tijuana. At the regional level, point source soil lead was associated with mean blood lead levels and concurrent high background, and point source soil lead levels were predictive of a high percentage of subjects with blood lead equal to or greater than 10 μg/dL (pe 10). Significant relationships were observed between mean blood lead level and fixed point source soil lead (r=0.93; P 2 =0.72 using a quadratic model) and between residential soil lead and fixed point source soil lead (r=0.90; P 2 =0.86 using a cubic model). This study suggests that point sources alone are not sufficient for predicting the relative risk of exposure to lead in the urban environment. These findings will be useful in defining regions for targeted or universal soil lead sampling by site type. Point sources have been observed to be predictive of mean blood lead at the regional level; however, this relationship alone was not sufficient to predict pe 10. It is concluded that when apparently undisturbed sites reveal high soil lead levels in addition to local point sources, dispersion of lead is widespread and will be associated with a high prevalence of elevated blood lead in children. Multiple strata sampling was shown to be useful in

  6. Technical aspects and preliminary results of the CCD camera diagnostics on Extrap T2

    International Nuclear Information System (INIS)

    Cecconello, M.; Brzozowski, J.

    1999-01-01

    During the last months of Extrap T2 operations an imaging acquisition system, based on charge-coupled devices (CCD) cameras, has been operated. CCD cameras are a standard diagnostic used in many fusion experiments: i) to obtain a direct insight of the plasma behaviour during the pulse, of the evolution of plasma-wall interactions and, eventually, of locked modes, ii) to measure local quantities such as the wall temperature and the impurity influxes, iii) to study the hydrogen recycling behaviour and iv) to estimate the poloidal and toroidal mode numbers. One of the aims of our imaging campaign was to check the utility of such diagnostic for T2. The purpose of this report is to describe the technical aspects involved in the use of such diagnostic and to briefly describe the results obtained. In this view, this report aims to be a guide to the development of a dedicated image acquisition system for Extrap T2, after the planned rebuild, by stressing the problems and limitations encountered during this campaign

  7. Single-Pulse Dual-Energy Mammography Using a Binary Screen Coupled to Dual CCD Cameras

    Science.gov (United States)

    1999-08-01

    Fossum, "Active pixel sensors—Are CCD’s Dinosaurs ?," Proc. SPIE 1900, 2-14 (1993). "S. Mendis, S. E. Kemeny, R. Gee, B. Pain, and E. R. Fossum, "Progress...Clin Oncol 13:1470-1477, 1995 12. Wahl RL, Zasadny K, Helvie M, et al: Metabolic monitoring of breast cancer chemohormonotherapy using posi- tron

  8. Comparison of a CCD and an APS for soft x-ray diffraction

    OpenAIRE

    Stewart, G.; Bates, R.; Blue, A.; Clark, A.; Dhesi, S.S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost.\\ud \\ud The AP...

  9. Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction

    Science.gov (United States)

    Shokr, M.; Schlosser, D.; Abboud, A.; Algashi, A.; Tosson, A.; Conka, T.; Hartmann, R.; Klaus, M.; Genzel, C.; Strüder, L.; Pietsch, U.

    2017-12-01

    Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 μm. However, for silicon based detectors the quantum efficiency for hard X-rays drops significantly for photon energies above 10 keV . This drawback can be overcome by combining a pixelated silicon-based detector system with a columnar scintillator. Here we report on the characterization of a low noise, fully depleted 128×128 pixels pnCCD detector with 75×75 μm2 pixel size coupled to a 700 μm thick columnar CsI(Tl) scintillator in the photon range between 1 keV to 130 keV . The excellent performance of the detection system in the hard X-ray range is demonstrated in a Laue type X-ray diffraction experiment performed at EDDI beamline of the BESSY II synchrotron taken at a set of several GaAs single crystals irradiated by white synchrotron radiation. With the columnar structure of the scintillator, the position resolution of the whole system reaches a value of less than one pixel. Using the presented detector system and considering the functional relation between indirect and direct photon events Laue diffraction peaks with X-ray energies up to 120 keV were efficiently detected. As one of possible applications of the combined CsI-pnCCD system we demonstrate that the accuracy of X-ray structure factors extracted from Laue diffraction peaks can be significantly improved in hard X-ray range using the combined CsI(Tl)-pnCCD system compared to a bare pnCCD.

  10. Multi-spectral CCD camera system for ocean water color and seacoast observation

    Science.gov (United States)

    Zhu, Min; Chen, Shiping; Wu, Yanlin; Huang, Qiaolin; Jin, Weiqi

    2001-10-01

    One of the earth observing instruments on HY-1 Satellite which will be launched in 2001, the multi-spectral CCD camera system, is developed by Beijing Institute of Space Mechanics & Electricity (BISME), Chinese Academy of Space Technology (CAST). In 798 km orbit, the system can provide images with 250 m ground resolution and a swath of 500 km. It is mainly used for coast zone dynamic mapping and oceanic watercolor monitoring, which include the pollution of offshore and coast zone, plant cover, watercolor, ice, terrain underwater, suspended sediment, mudflat, soil and vapor gross. The multi- spectral camera system is composed of four monocolor CCD cameras, which are line array-based, 'push-broom' scanning cameras, and responding for four spectral bands. The camera system adapts view field registration; that is, each camera scans the same region at the same moment. Each of them contains optics, focal plane assembly, electrical circuit, installation structure, calibration system, thermal control and so on. The primary features on the camera system are: (1) Offset of the central wavelength is better than 5 nm; (2) Degree of polarization is less than 0.5%; (3) Signal-to-noise ratio is about 1000; (4) Dynamic range is better than 2000:1; (5) Registration precision is better than 0.3 pixel; (6) Quantization value is 12 bit.

  11. War-related trauma exposure and multiple risk behaviors among school-going adolescents in Northern Uganda: the mediating role of depression symptoms.

    Science.gov (United States)

    Okello, James; Nakimuli-Mpungu, Etheldreda; Musisi, Seggane; Broekaert, Eric; Derluyn, Ilse

    2013-11-01

    The relationship between war-related trauma exposure, depressive symptoms and multiple risk behaviors among adolescents is less clear in sub-Saharan Africa. We analyzed data collected from a sample of school-going adolescents four years postwar. Participants completed interviews assessing various risk behaviors defined by the Youth Self Report (YSR) and a sexual risk behavior survey, and were screened for post-traumatic stress, anxiety and depression symptoms based on the Impact of Events Scale Revised (IESR) and Hopkins Symptom Checklist for Adolescents (HSCL-37A) respectively. Multivariate logistic regression was used to assess factors independently associated with multiple risk behaviors. The logistic regression model of Baron and Kenny (1986) was used to evaluate the mediating role of depression in the relationship between stressful war events and multiple risk behaviors. Of 551 participants, 139 (25%) reported multiple (three or more) risk behaviors in the past year. In the multivariate analyses, depression symptoms remained uniquely associated with multiple risk behavior after adjusting for potential confounders including socio-demographic characteristics, war-related trauma exposure variables, anxiety and post-traumatic stress symptoms. In mediation analysis, depression symptoms mediated the associations between stressful war events and multiple risk behaviors. The psychometric properties of the questionnaires used in this study are not well established in war affected African samples thus ethno cultural variation may decrease the validity of our measures. Adolescents with depression may be at a greater risk of increased engagement in multiple risk behaviors. Culturally sensitive and integrated interventions to treat and prevent depression among adolescents in post-conflict settings are urgently needed. © 2013 Elsevier B.V. All rights reserved.

  12. BVRI CCD photometry of the metal-poor globular cluster M68 (NGC 4590)

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.; Wenderoth, E.

    1990-01-01

    BVRI photometry of the low metallicity globular cluster M68 (NGC 4590) was obtained with a CCD camera and the 2.2-m ESO telescope. The resulting BV color-magnitude diagrams are compared with the observations of McClure et al. (1987). The observations are also compared with theoretical isochrones, yielding a cluster age of 13 Gyr with a likely external uncertainty of 2 or 3 Gyr. 25 refs

  13. PTSD and Comorbid Disorders in a Representative Sample of Adolescents: The Risk Associated with Multiple Exposures to Potentially Traumatic Events

    Science.gov (United States)

    Macdonald, Alexandra; Danielson, Carla Kmett; Resnick, Heidi S.; Saunders, Benjamin E.; Kilpatrick, Dean G.

    2010-01-01

    Objective: This study compared the impact of multiple exposures to potentially traumatic events (PTEs), including sexual victimization, physical victimization, and witnessed violence, on posttraumatic stress disorder (PTSD) and comorbid conditions (i.e., major depressive episode [MDE], and substance use [SUD]). Methods: Participants were a…

  14. Exposure to predator odor influences the relative use of multiple memory systems: role of basolateral amygdala.

    Science.gov (United States)

    Leong, Kah-Chung; Packard, Mark G

    2014-03-01

    In a dual-solution plus-maze task in which both hippocampus-dependent place learning and dorsolateral striatal-dependent response learning provide an adequate solution, the relative use of multiple memory systems can be influenced by emotional state. Specifically, pre-training peripheral or intra-basolateral (BLA) administration of anxiogenic drugs result in the predominant use of response learning. The present experiments were designed to extend these findings by examining whether exposure to a putatively ethologically valid stressor would also produce a predominant use of response learning. In experiment 1, adult male Long-Evans rats were exposed to either a predator odor (trimethylthiazoline [TMT], a component of fox feces) or distilled water prior to training in a dual-solution water plus maze task. On a probe trial 24h following task acquisition, rats previously exposed to TMT predominantly displayed response learning relative to control animals. In experiment 2, rats trained on a single-solution plus maze task that required the use of response learning displayed enhanced acquisition following pre-training TMT exposure. In experiment 3, rats exposed to TMT or distilled water were trained in the dual-solution task and received post-training intra-BLA injections of the sodium channel blocker bupivacaine (1.0% solution, 0.5 μl) or saline. Relative to control animals, rats exposed to TMT predominantly displayed response learning on the probe trial, and this effect was blocked by neural inactivation of the BLA. The findings indicate that (1) the use of dorsal striatal-dependent habit memory produced by emotional arousal generalizes from anxiogenic drug administration to a putatively ecologically valid stressor (i.e. predator odor), and (2) the BLA mediates the modulatory effect of exposure to predator odor on the relative use of multiple memory systems. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Comparing population exposure to multiple Washington earthquake scenarios for prioritizing loss estimation studies

    Science.gov (United States)

    Wood, Nathan J.; Ratliff, Jamie L.; Schelling, John; Weaver, Craig S.

    2014-01-01

    Scenario-based, loss-estimation studies are useful for gauging potential societal impacts from earthquakes but can be challenging to undertake in areas with multiple scenarios and jurisdictions. We present a geospatial approach using various population data for comparing earthquake scenarios and jurisdictions to help emergency managers prioritize where to focus limited resources on data development and loss-estimation studies. Using 20 earthquake scenarios developed for the State of Washington (USA), we demonstrate how a population-exposure analysis across multiple jurisdictions based on Modified Mercalli Intensity (MMI) classes helps emergency managers understand and communicate where potential loss of life may be concentrated and where impacts may be more related to quality of life. Results indicate that certain well-known scenarios may directly impact the greatest number of people, whereas other, potentially lesser-known, scenarios impact fewer people but consequences could be more severe. The use of economic data to profile each jurisdiction’s workforce in earthquake hazard zones also provides additional insight on at-risk populations. This approach can serve as a first step in understanding societal impacts of earthquakes and helping practitioners to efficiently use their limited risk-reduction resources.

  16. Charge loss experiments in surface channel CCD's explained by the McWhorter interface states model

    NARCIS (Netherlands)

    Penning De Vries, R.G.M.; Wallinga, Hans

    1985-01-01

    On the basis of the McWhorter interface states model the CCD charge loss is derived as a function of bias charge, signal charge and channel width. As opposed to existing models, the charge loss is now attributed to interface states in the entire gate area, even for high bias charge levels.

  17. A Binary Offset Effect in CCD Readout and Its Impact on Astronomical Data

    Science.gov (United States)

    Boone, K.; Aldering, G.; Copin, Y.; Dixon, S.; Domagalski, R. S.; Gangler, E.; Pecontal, E.; Perlmutter, S.

    2018-06-01

    We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two, and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a variety of telescopes and many different front-end electronics systems. The affected instruments include LRIS and DEIMOS on the Keck telescopes, WFC3 UVIS and STIS on HST, MegaCam on CFHT, SNIFS on the UH88 telescope, GMOS on the Gemini telescopes, HSC on Subaru, and FORS on VLT. The amplitude of the introduced offset is up to 4.5 ADU per pixel, and it is not directly proportional to the measured ADU level. We have developed a model that can be used to detect this “binary offset effect” in data, and correct for it. Understanding how data are affected and applying a correction for the effect is essential for precise astronomical measurements.

  18. BV photographic and CCD photometry of IC 4651

    International Nuclear Information System (INIS)

    Anthony-Twarog, B.J.; Mukherjee, K.; Twarog, B.A.; Caldwell, N.

    1988-01-01

    A BV photometric survey in IC 4651 based on photographic and CCD material calibrated with photoelectric photometry from Eggen (1971) and Anthony-Twarog and Twarog (1987) has been completed. The color-magnitude diagram is consistent with an age of 2.4 + or - 0.3 x 10 to the 9th yr derived by comparison with the isochrones of VandenBerg (1985) if the apparent distance modulus and reddening derived from uvby photometry in Anthony-Twarog and Twarog (1987) are employed. While evidence is found of a hook in the upper main sequence, no evidence is found of a significantly bifurcated main sequence for this cluster, although it is similar in age to NGC 752 and NGC 3680, where this phenomenon has been noted. Finally, the survey has not resolved the apparent deficit of main-sequence stars fainter than V = 14.5 noted in Anthony-Twarog and Twarog (1987). 16 references

  19. Understanding the Impact of Exposure Patterns on Risks from Combined Exposures to Multiple Chemicals

    Science.gov (United States)

    The talk was invited so there is no formal abstract. However, the focus of the talk is on the use of exposure information in the evaluation of risks from combined exposures to chemicals. The talk presents a bit of history and several case studies. All empirical data presented hav...

  20. Jets from young stars - CCD imaging, long-slit spectroscopy, and interpretation of existing data

    International Nuclear Information System (INIS)

    Mundt, R.; Brugel, E.W.; Buehrke, T.

    1987-01-01

    High-velocity jets and collimated outflows are now recognized as phenomena commonly associated with young stars. New CCD imaging of five objects, and in particular spatially resolved spectroscopy of eight highly-collimated flows, are discussed. Through the CCD imaging, three new jets have been discovered. It is shown that several previously known Herbig-Haro objects have extended bow-shock-like structures. In most of the latter cases, a jet is pointing from the star toward the bow-shock apex. The concave side of the bow-shock structure is in all cases oriented toward the outflow source. Using a data base of about 20 known jets, a detailed list of observational criteria describing these phenomena is compiled. A physical description and interpretation is presented which discusses the origin of knots in these jets and other structures, the relationship between jets and Herbig-Haro objects, the dissipation of energy along the jet due to internal shocks, the physical parameters, the relationship of optical jets to molecular outflows, and time scales for outflow activity. A short discussion of the driving sources for these jets is also included. 116 references

  1. Development of a CCD based system called DIGITRACK for automatic track counting and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, J.; Somogyi, G.; Szilagyi, S.; Sepsy, K. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    We have developed, to the best of our knowledge, the first automatic track analysis system (DIGITRACK) in which the video signals are processed by a new type of video-receiver called charge-coupled device (CCD). The photosensitive semi-conductor device is a 2.5 cm long line imager of type Fairchild CCD 121HC which converts one row of the picture seen through a low magnification microscope into 1728 binary signals by a thresholding logic. The picture elements are analysed by a microcomputer equipped with two INTEL 8080 microprocessors and interfaced to a PDP-11/40 computer. The microcomputer also controls the motion of the stage of microscope. For pattern recognition and analysis a software procedure is developed which is able to differentiate between overlapping tracks and to determine the number, surface opening and x-y coordinates of the tracks occurring in a given detector area. The distribution of track densities and spot areas on the detector surface can be visualized on a graphic display. The DIGITRACK system has been tested for analysis of alpha-tracks registered in CR-39 and LR-115 detectors.

  2. 32x32 HgCdTe/CCD infrared camera for the 2-5 micron range

    International Nuclear Information System (INIS)

    Monin, J.L.; Vauglin, I.; Sibille, F.

    1988-01-01

    The paper presents a complete infrared camera system, based on a high electron capacity detector (HgCdTe/CCD), that has been used under high background conditions to generate astronomical images. The performance of the system and some results are presented, and the use of such a detector in astronomy is discussed. 8 references

  3. Medición de posiciones astrométricas con CCD en la zona de Rup 21

    Science.gov (United States)

    Bustos Fierro, I. H.; Calderón, J. H.

    It is shown the utilization of the block adjustment method for the measurement of astrometric positions from a mosaic of sixteen CCD images with partial overlap, which were taken with the Telescope Jorge Sahade of CASLEO. The observations cover an area of 25' x 25' around the open cluster Rup21. The source of reference positions was ACT Reference Catalog. The internal error of the measured positions is analyzed, and the external error is estimated from the comparison with the catalog USNO-A. In this comparison it is found that the direct CCD images taken with focal reducer could be distorted by severe field curvature. The effect of the distortion presumably introduced by the optics is eliminated with the suitable corrections of the stellar positions measured on every frame, but a new systematic effect on scales of the entire field is observed, which could be due to the distribution of the reference stars.

  4. Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis

    Directory of Open Access Journals (Sweden)

    Rolanas Dauksevicius

    2013-04-01

    Full Text Available Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner’s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.

  5. Effects of multiple scattering and atmospheric aerosol on the polarization of the twilight sky

    International Nuclear Information System (INIS)

    Ugolnikov, Oleg S.; Postylyakov, Oleg V.; Maslov, Igor A.

    2004-01-01

    The paper presents a review of a number of wide-angle polarization CCD-measurements of the twilight sky in V and R color bands with effective wavelengths 550 and 700nm. The basic factors affecting (usually decreasing) the polarization of the twilight sky are the atmospheric aerosol scattering and multiple scattering. These effects were distinguished from each other, and a method of multiple-scattering separation is discussed. The results are compared with the data of numerical simulation of radiative transfer in the atmosphere for different aerosol models. The whole twilight period is divided into different stages with different mechanisms forming the twilight-sky polarization properties

  6. Media Exposure in Low-Income Preschool-Aged Children Is Associated with Multiple Measures of Self-Regulatory Behavior.

    Science.gov (United States)

    Munzer, Tiffany G; Miller, Alison L; Peterson, Karen E; Brophy-Herb, Holly E; Horodynski, Mildred A; Contreras, Dawn; Sturza, Julie; Lumeng, Julie C; Radesky, Jenny

    2018-05-01

    Excessive screen media exposure in childhood is associated with parent-reported self-regulation difficulties. No studies have used laboratory-based or teacher-reported measures of child self-regulatory behaviors. This study examines cross-sectional associations between preschooler screen media exposure and multiple measures of self-regulatory behaviors. Preintervention data were used from 541 preschoolers in the Growing Healthy study, an obesity prevention trial (2011-2015). Screen media exposure was measured by daily screen media exposure (hr/d), television (TV) in the bedroom, frequency of background TV, and TV with meals (1 = rarely/never, 4 = frequently). Child self-regulatory behaviors were measured by the following: child ability to delay gratification, a standardized waiting paradigm; teacher-reported Social Competence and Behavior Evaluation; and parent-reported difficult temperament on the Child Behavior Questionnaire (CBQ). Multivariate regression analyses modeled screen media exposure predicting each self-regulatory measure, adjusting for child age, sex, parent age, education, marital status, income-to-needs ratio, number of adults in household, parent depressive symptoms, and sensitivity. Children were aged 4.1 years (SD = 0.5), parents were aged 29.6 years (SD = 6.8), 48% had high school education or less, and 67% were married. Daily screen media exposure and background TV were associated with weaker observed self-regulation (β: -10.30 seconds for each hr/d media, -12.63 seconds for 1-point increase, respectively). Background TV and TV with meals were associated with greater parent-reported difficult temperament (β: 0.04 and 0.05 CBQ, respectively, for 1-point increase). Greater screen media exposure had small but significant associations with weaker observed and parent-reported, but not teacher-reported, self-regulatory behaviors. Longitudinal studies are needed to determine the directionality of associations.

  7. Multiple sclerosis and organic solvents

    DEFF Research Database (Denmark)

    Mortensen, J T; Brønnum-Hansen, Henrik; Rasmussen, K

    1998-01-01

    We investigated a possible causal relation between exposure to organic solvents in Danish workers (housepainters, typographers/printers, carpenters/cabinetmakers) and onset of multiple sclerosis. Data on men included in the Danish Multiple Sclerosis Register (3,241 men) were linked with data from......, and butchers. Over a follow-up period of 20 years, we observed no increase in the incidence of multiple sclerosis among men presumed to be exposed to organic solvents. It was not possible to obtain data on potential confounders, and the study design has some potential for selection bias. Nevertheless......, the study does not support existing hypotheses regarding an association between occupational exposure to organic solvents and multiple sclerosis....

  8. Deep CCD survey - galaxy luminosity and color evolution

    International Nuclear Information System (INIS)

    Tyson, J.A.

    1988-01-01

    Imaging and photometric observations of a statistically complete sample of galaxies in 12 high-latitude fields, obtained in the BJ (360-520 nm), R (580-720 nm) and I (780-1100 nm) bands using CCD detectors on the 4-m telescopes at CTIO and KPNO, are reported. The data are presented in extensive graphs and sample images and analyzed in detail with reference to theoretical models of galactic origin and evolution. The galaxy number-count slopes, d(log N)/dm, are found to be sub-Euclidean, varying from 0.34 in the I band to 0.45 in the BJ band, where the corrected counts appear to saturate at about 27 mag. The predictions of no-evolution models are shown to underpredict the counts at 25 mag (BJ) by a factor of 5-15 and the extragalactic background light from all galaxies (6.8 x 10 to the -6th erg/sq cm sec sr micron at 450 nm) by a factor greater than 2. 114 references

  9. Defect testing of large aperture optics based on high resolution CCD camera

    International Nuclear Information System (INIS)

    Cheng Xiaofeng; Xu Xu; Zhang Lin; He Qun; Yuan Xiaodong; Jiang Xiaodong; Zheng Wanguo

    2009-01-01

    A fast testing method on inspecting defects of large aperture optics was introduced. With uniform illumination by LED source at grazing incidence, the image of defects on the surface of and inside the large aperture optics could be enlarged due to scattering. The images of defects were got by high resolution CCD camera and microscope, and the approximate mathematical relation between viewing dimension and real dimension of defects was simulated. Thus the approximate real dimension and location of all defects could be calculated through the high resolution pictures. (authors)

  10. Effects of Multiple Routes of Cadmium Exposure on the Hibernation Success of the American Toad (Bufo americanus)

    Science.gov (United States)

    James, S.M.; Little, E.E.; Semlitsch, R.D.

    2004-01-01

    The effects of multiple routes of cadmium exposure on juvenile American toads (Bufo americanus) were evaluated using environmentally relevant concentrations. During or after exposure, toads were individually hibernated for 172 days at approximately 4??C. The following experiments were conducted: (1) dermal exposure (hibernation in soil contaminated with up to 120 ??g Cd/ g (dry weight)); (2) injection exposure (single injection with cadmium to achieve a maximum whole-body nominal concentration of 3 ??g Cd/g (wet weight) 12 days before hibernation in uncontaminated soil); and, (3) oral exposure (feeding with mealworms containing ???16 ??g Cd/g (dry weight) for 50 days before hibernation in uncontaminated soil)., We hypothesized that sublethal levels of cadmium would become lethal during hibernation because of combined chemical and cold stress. No prehibernation mortality occurred in the injection and oral exposure studies. There was a significant treatment effect on whole-body cadmium concentration in toads orally or dermally exposed and on percent of cadmium retention in toads orally exposed. There was also a trend of increased time-to-burrowing and more toads partially buried with greater cadmium concentration in the dermal study, which indicated avoidance. In all 3 experiments, no significant differences were found among cadmium treatments in hibernation survival, percent of mass loss, or locomotor performance. However, toads fed mealworms averaging 4.7 ??g Cd/g (dry weight) had only 56% survival compared with 100% survival for controls. Although our results suggest that environmentally relevant levels of cadmium do not pose a great risk to American toads, factors such as soil type or prey species may increase cadmium bioavailability, and other amphibian species may be more sensitive to cadmium than B. americanus.

  11. Miniature CCD X-Ray Imaging Camera Technology Final Report CRADA No. TC-773-94

    Energy Technology Data Exchange (ETDEWEB)

    Conder, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mummolo, F. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-19

    The goal of the project was to develop a compact, large active area, high spatial resolution, high dynamic range, charge-coupled device (CCD) camera to replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating X-rays. The camera head and controller needed to be capable of operation within a vacuum environment and small enough to be fielded within the small vacuum target chambers at LLNL.

  12. Scintillator-CCD camera system light output response to dosimetry parameters for proton beam range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Daftari, Inder K., E-mail: idaftari@radonc.ucsf.edu [Department of Radiation Oncology, 1600 Divisadero Street, Suite H1031, University of California-San Francisco, San Francisco, CA 94143 (United States); Castaneda, Carlos M.; Essert, Timothy [Crocker Nuclear Laboratory,1 Shields Avenue, University of California-Davis, Davis, CA 95616 (United States); Phillips, Theodore L.; Mishra, Kavita K. [Department of Radiation Oncology, 1600 Divisadero Street, Suite H1031, University of California-San Francisco, San Francisco, CA 94143 (United States)

    2012-09-11

    The purpose of this study is to investigate the luminescence light output response in a plastic scintillator irradiated by a 67.5 MeV proton beam using various dosimetry parameters. The relationship of the visible scintillator light with the beam current or dose rate, aperture size and the thickness of water in the water-column was studied. The images captured on a CCD camera system were used to determine optimal dosimetry parameters for measuring the range of a clinical proton beam. The method was developed as a simple quality assurance tool to measure the range of the proton beam and compare it to (a) measurements using two segmented ionization chambers and water column between them, and (b) with an ionization chamber (IC-18) measurements in water. We used a block of plastic scintillator that measured 5 Multiplication-Sign 5 Multiplication-Sign 5 cm{sup 3} to record visible light generated by a 67.5 MeV proton beam. A high-definition digital video camera Moticam 2300 connected to a PC via USB 2.0 communication channel was used to record images of scintillation luminescence. The brightness of the visible light was measured while changing beam current and aperture size. The results were analyzed to obtain the range and were compared with the Bragg peak measurements with an ionization chamber. The luminescence light from the scintillator increased linearly with the increase of proton beam current. The light output also increased linearly with aperture size. The relationship between the proton range in the scintillator and the thickness of the water column showed good linearity with a precision of 0.33 mm (SD) in proton range measurement. For the 67.5 MeV proton beam utilized, the optimal parameters for scintillator light output response were found to be 15 nA (16 Gy/min) and an aperture size of 15 mm with image integration time of 100 ms. The Bragg peak depth brightness distribution was compared with the depth dose distribution from ionization chamber measurements

  13. Chromatic Modulator for High Resolution CCD or APS Devices

    Science.gov (United States)

    Hartley, Frank T. (Inventor); Hull, Anthony B. (Inventor)

    2003-01-01

    A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

  14. BVI CCD photometry of the globular cluster M4

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.

    1988-01-01

    CCD BV1 main-sequence (MS) photometry of M4, the globular cluster closest to the sun, is presented. The photometry is matched to the BVI isochrones of VandenBerg and Bell (1985). The MS turnoffs are found to be at V = 16.90 + or - 0.05, B-V = 0.81 + or - 0.02, V-I = 0.96 + or - 0.02, and B - I = 1.77 + or - 0.02. The magnitude difference between the MS turnoff and the horizontal branch is Delta M(V) = 3.52 + or - 0.1 for all three color indices. Using Y = 0.2, (Fe/H) = - 1.27, and alpha = 1.65, with a distance modulus of (m-M)V = 12.7 and E(B-V) = 0.41, a consistent age for M4 is deduced in all three color indices of 17 + or - 1.5 Gyr. 34 references

  15. The thin-walled abnormity measurement technology research based on CCD

    International Nuclear Information System (INIS)

    Wang Bin

    2014-01-01

    The character of the thin-walled irregular parts is: the measured parameters for spatial structure size, need to design special measurement positioning fixture to complete detection, the wall thickness is very thin, and the processing is composite, its size is small and shape is complex, it is difficulty to collect image edge by using the optical measurement method. In this paper, a special measurement method of CCD that based on the image measurement technique was advanced, this kind of parts was measured quickly, accurately and automaticly through design the high precision positioning fixture and image acquisition method. At the same time, the comprehensive evaluation standard was given to assess the measurement accuracy method, and the reliability of measurement method was ensured. (author)

  16. Electromagnetic Compatibility Assessment of CCD Detector Acquisition Chains not Synchronized

    Science.gov (United States)

    Nicoletto, M.; Boschetti, D.; Ciancetta, E.; Maiorano, E.; Stagnaro, L.

    2016-05-01

    Euclid is a space observatory managed by the European Space Agency; it is the second medium class mission (see Figure 1) in the frame of Cosmic Vision 2015-2025 program.In the frame of this project, the electromagnetic interference between two different and not synchronized Charge Coupled Device (CCD) (see Figure 2) acquisition chains has been evaluated. The key parameter used for this assessment is the electromagnetic noise induced on each other. Taking into account the specificity of the issue, radiation coupling at relative low frequency and in near field conditions, classical approach based on simulations and testing on qualification model cannot be directly applied. Based on that, it has been decided to investigate the issue by test in an incremental way.

  17. EVALUATION OF RATIONAL FUNCTION MODEL FOR GEOMETRIC MODELING OF CHANG'E-1 CCD IMAGES

    Directory of Open Access Journals (Sweden)

    Y. Liu

    2012-08-01

    Full Text Available Rational Function Model (RFM is a generic geometric model that has been widely used in geometric processing of high-resolution earth-observation satellite images, due to its generality and excellent capability of fitting complex rigorous sensor models. In this paper, the feasibility and precision of RFM for geometric modeling of China's Chang'E-1 (CE-1 lunar orbiter images is presented. The RFM parameters of forward-, nadir- and backward-looking CE-1 images are generated though least squares solution using virtual control points derived from the rigorous sensor model. The precision of the RFM is evaluated by comparing with the rigorous sensor model in both image space and object space. Experimental results using nine images from three orbits show that RFM can precisely fit the rigorous sensor model of CE-1 CCD images with a RMS residual error of 1/100 pixel level in image space and less than 5 meters in object space. This indicates that it is feasible to use RFM to describe the imaging geometry of CE-1 CCD images and spacecraft position and orientation. RFM will enable planetary data centers to have an option to supply RFM parameters of orbital images while keeping the original orbit trajectory data confidential.

  18. US exposure to multiple landscape stressors and climate change

    Science.gov (United States)

    Becky K. Kerns; John B. Kim; Jeffrey D. Kline; Michelle A. Day

    2016-01-01

    We examined landscape exposure to wildfire potential, insects and disease risk, and urban and exurban development for the conterminous US (CONUS). Our analysis relied on spatial data used by federal agencies to evaluate these stressors nationally. We combined stressor data with a climate change exposure metric to identify when temperature is likely to depart from...

  19. Production of β-ionone by combined expression of carotenogenic and plant CCD1 genes in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Lopez, Javiera; Essus, Karen; Kim, Il-Kwon

    2015-01-01

    cells. The additional integration of the carotenoid cleavage dioxygenase gene from the plant Petunia hybrida (PhCCD1) let to the production of low amounts of beta-ionone (0.073 ± 0.01 mg/g DCW) and changed the color of the strain from orange to yellow. The expression of the crtYB gene from a high copy......, the carotenogenic crtYB, crtI genes and the plant PhCCD1 gene-the highest β-ionone concentration reported to date by a cell factory was achieved. This microbial cell factory represents a starting point for flavor production by a sustainable and efficient process that could replace current methods.......Background: Apocarotenoids, like the C13-norisoprenoids, are natural compounds that contribute to the flavor and/or aroma of flowers and foods. They are produced in aromatic plants-like raspberries and roses-by the enzymatic cleavage of carotenes. Due to their pleasant aroma and flavour...

  20. The development of a methodology to assess population doses from multiple sources and exposure pathways of radioactivity

    International Nuclear Information System (INIS)

    Hancox, J.; Stansby, S.; Thorne, M.

    2002-01-01

    The Environment Agency (EA) has new duties in accordance with the Basic Safety Standards Directive under which it is required to ensure that doses to individuals received from exposure to anthropogenic sources of radioactivity are within defined limits. In order to assess compliance with these requirements, the EA needs to assess the doses to members of the most highly exposed population groups ('critical' groups) from all relevant potential sources of anthropogenic radioactivity and all relevant potential exposure pathways to such radioactivity. The EA has identified a need to develop a methodology for the retrospective assessment of effective doses from multiple sources of radioactive materials and exposure pathways associated with those sources. Under contract to the EA, AEA Technology has undertaken the development of a suitable methodology as part of EA R and D Project P3-070. The methodology developed under this research project has been designed to support the EA in meeting its obligations under the Euratom Basic Safety Standards Directive and is consistent with UK and international approaches to radiation dosimetry and radiological protection. The development and trial application of the methodology is described in this report

  1. A CCD-based system for the detection of DNA in electrophoresis gels by UV absorption

    International Nuclear Information System (INIS)

    Mahon, A.R.; MacDonald, J.H.; Mainwood, A.; Ott, R.J.

    1999-01-01

    A method and apparatus for the detection and quantification of large fragments of unlabelled nucleic acids in agarose gels is presented. The technique is based on ultraviolet (UV) absorption by nucleotides. A deuterium source illuminates individual sample lanes of an electrophoresis gel via an array of optical fibres. As DNA bands pass through the illuminated region of the gel the amount of UV light transmitted is reduced because of absorption by the DNA. During electrophoresis the regions of DNA are detected on-line using a UV-sensitive charge coupled device (CCD). As the absorption coefficient is proportional to the mass of DNA the technique is inherently quantitative. The mass of DNA in a region of the gel is approximately proportional to the integrated signal in the corresponding section of the CCD image. This system currently has a detection limit of less than 1.25 ng compared with 2-10 ng for the most popular conventional technique, ethidium bromide (EtBr) staining. In addition the DNA sample remains in its native state. The removal of the carcinogenic dye from the detection procedure greatly reduces associated biological hazards. (author)

  2. Spectral interference of zirconium on 24 analyte elements using CCD based ICP-AES technique

    International Nuclear Information System (INIS)

    Adya, V.C.; Sengupta, Arijit; Godbole, S.V.

    2014-01-01

    In the present studies, the spectral interference of zirconium on different analytical lines of 24 critical analytes using CCD based ICP-AES technique is described. Suitable analytical lines for zirconium were identified along with their detection limits. The sensitivity and the detection limits of analytical channels for different elements in presence of Zr matrix were calculated. Subsequently analytical lines with least interference from Zr and better detection limits were selected for their determinations. (author)

  3. Data Reduction and Control Software for Meteor Observing Stations Based on CCD Video Systems

    Science.gov (United States)

    Madiedo, J. M.; Trigo-Rodriguez, J. M.; Lyytinen, E.

    2011-01-01

    The SPanish Meteor Network (SPMN) is performing a continuous monitoring of meteor activity over Spain and neighbouring countries. The huge amount of data obtained by the 25 video observing stations that this network is currently operating made it necessary to develop new software packages to accomplish some tasks, such as data reduction and remote operation of autonomous systems based on high-sensitivity CCD video devices. The main characteristics of this software are described here.

  4. Comparative Analysis of Chinese HJ-1 CCD, GF-1 WFV and ZY-3 MUX Sensor Data for Leaf Area Index Estimations for Maize

    Directory of Open Access Journals (Sweden)

    Jing Zhao

    2018-01-01

    Full Text Available In recent years, China has developed and launched several satellites with high spatial resolutions, such as the resources satellite No. 3 (ZY-3 with a multi-spectral camera (MUX and 5.8 m spatial resolution, the satellite GaoFen No. 1 (GF-1 with a wide field of view (WFV camera and 16 m spatial resolution, and the environment satellite (HJ-1A/B with a charge-coupled device (CCD sensor and 30 m spatial resolution. First, to analyze the potential application of ZY-3 MUX, GF-1 WFV, and HJ-1 CCD to extract the leaf area index (LAI at the regional scale, this study estimated LAI from the relationships between physical model-based spectral vegetation indices (SVIs and LAI values that were generated from look-up tables (LUTs, simulated from the combination of the PROSPECT-5B leaf model and the scattering by arbitrarily inclined leaves with the hot-spot effect (SAILH canopy reflectance model. Second, to assess the surface reflectance quality of these sensors after data preprocessing, the well-processed surface reflectance products of the Landsat-8 operational land imager (OLI sensor with a convincing data quality were used to compare the performances of ZY-3 MUX, GF-1 WFV, and HJ-1 CCD sensors both in theory and reality. Apart from several reflectance fluctuations, the reflectance trends were coincident, and the reflectance values of the red and near-infrared (NIR bands were comparable among these sensors. Finally, to analyze the accuracy of the LAI estimated from ZY-3 MUX, GF-1 WFV, and HJ-1 CCD, the LAI estimations from these sensors were validated based on LAI field measurements in Huailai, Hebei Province, China. The results showed that the performance of the LAI that was inversed from ZY-3 MUX was better than that from GF-1 WFV, and HJ-1 CCD, both of which tended to be systematically underestimated. In addition, the value ranges and accuracies of the LAI inversions both decreased with decreasing spatial resolution.

  5. Inversion of CDOM and COD in water using HJ-1/CCD data

    International Nuclear Information System (INIS)

    Huang, Miaofen; Xing, Xufeng; Zhao, Zulong; Li, Zhanqiang; Wang, Xinxing

    2014-01-01

    With the in-situ measurement data including the absorption coefficient of the CDOM, apparent optical properties and the COD, a regression model was established for retrieving ag(440) based on the remote sensing reflectance of the first and the third band of the environment satellite HJ-1/CCD. The measurement data were obtained at the regions of Panjin, Liaoning province in May 2008 and August 2009. Secondly, the remote sensing regression model was created based on the correlation of the CDOM optical properties and the COD. Finally, using the HJ-1/CCD data from 2009 to 2011 in Liaodong bay, the thematic snapshots of water environmental parameters in coastal waters, such as the CDOM and the COD, were calculated and analyzed. The results showed that: (1) the distribution of the CDOM tends to decrease from offshore areas to distant sea with some zonated character; (2) Most of the retrieved CDOM values vary between 0.2–1.7m-1, which is consistent with the measured value in 2009 and 2010 years; (3) the spatial distribution of the COD has good consistency with the CDOM, also shows a certain zonated distribution in coastal-offshore areas; (4) in September 2009 and September 2011, the values of the COD was basically below 40 mg/L while the values of the COD in September 2010 are relatively higher, mostly above 55 mg/L; (5) in June 2011 and May 2010, the COD values are nearly all larger than 55 mg/L

  6. Assessment of multiple frequency ELF electric and magnetic field exposure

    International Nuclear Information System (INIS)

    Leitgeb, N

    2008-01-01

    Electromagnetic fields both in daily life and at workplaces exhibit increasingly complex frequency spectra. Present spectral assessment rules proved to be too conservative for health risk assessment. This is because they are based on the assumption that cells would react like linear systems in terms of responding to a sum of frequencies by a sum of independent responses to each individual frequency. Based on numerical investigations with the Hodgkin-Huxley and the Frankenhaeuser-Huxley nerve cell models, it could be shown that accounting for the nonlinear behaviour of cellular excitation processes avoids considerable overestimation of simultaneous exposures to multiple frequency ELF electric and magnetic fields. Besides this, it could be shown that the role of phase relationships is less important than that assumed so far. The present assessment rules lead to non-compliances of marketed electric appliances. For general application, a nonlinear biology-based assessment (NBBA) rule has been proposed, validated and proven advantageous compared with ICNIRP's rule. While staying conservative it avoids unnecessary overestimation and demonstrates compliance even in cases of suspected non-conformities. It is up to responsible bodies to decide upon the adoption of this proposal and the potential need for implementing additional or reducing the already incorporated safety factors

  7. Nighttime Near Infrared Observations of Augustine Volcano Jan-Apr, 2006 Recorded With a Small Astronomical CCD Camera

    Science.gov (United States)

    Sentman, D.; McNutt, S.; Reyes, C.; Stenbaek-Nielsen, H.; Deroin, N.

    2006-12-01

    Nighttime observations of Augustine Volcano were made during Jan-Apr, 2006 using a small, unfiltered, astronomical CCD camera operating from Homer, Alaska. Time-lapse images of the volcano were made looking across the open water of the Cook Inlet over a slant range of ~105 km. A variety of volcano activities were observed that originated in near-infrared (NIR) 0.9-1.1 micron emissions, which were detectable at the upper limit of the camera passband but were otherwise invisible to the naked eye. These activities included various types of steam releases, pyroclastic flows, rockfalls and debris flows that were correlated very closely with seismic measurements made from instruments located within 4 km on the volcanic island. Specifically, flow events to the east (towards the camera) produced high amplitudes on the eastern seismic stations and events presumably to the west were stronger on western stations. The ability to detect nighttime volcanic emissions in the NIR over large horizontal distances using standard silicon CCD technology, even in the presence of weak intervening fog, came as a surprise, and is due to a confluence of several mutually reinforcing factors: (1) Hot enough (~1000K) thermal emissions from the volcano that the short wavelength portion of the Planck radiation curve overlaps the upper portions (0.9-1.1 micron) of the sensitivity of the silicon CCD detectors, and could thus be detected, (2) The existence of several atmospheric transmission windows within the NIR passband of the camera for the emissions to propagate with relatively small attenuation through more than 10 atmospheres, and (3) in the case of fog, forward Mie scattering.

  8. Improved sensitivity high-definition interline CCD using the KODAK TRUESENSE color filter pattern

    Science.gov (United States)

    DiBella, James; Andreghetti, Marco; Enge, Amy; Chen, William; Stanka, Timothy; Kaser, Robert

    2010-01-01

    The KODAK TRUESENSE Color Filter Pattern has technology that for the first time is applied to a commercially available interline CCD. This 2/3" true-HD sensor will be described along with its performance attributes, including sensitivity improvement as compared to the Bayer CFA version of the same sensor. In addition, an overview of the system developed for demonstration and evaluation will be provided. Examples of the benefits of the new technology in specific applications including surveillance and intelligent traffic systems will be discussed.

  9. Cross-reacting carbohydrate determinants and hymenoptera venom allergy.

    Science.gov (United States)

    Brehler, Randolf; Grundmann, Sonja; Stöcker, Benedikt

    2013-08-01

    Insect venom allergy is an important cause of anaphylaxis. Venom immunotherapy assume the clear identification of the culprit insect, but this is impeded by Immunoglobulin E (IgE) antibodies to cross reactive carbohydrate determinant (CCD) epitopes of common glycoproteins. Here we give an overview about inducers, importance, and relevance of anti-N-Glycan CCD IgE antibodies. Pollen exposure and insect stings induce anti-CCD IgE antibodies interfering with in-vitro tests for allergy diagnosis due to extensive IgE cross-reactivity. Instead of being biologically active these antibodies are irrelevant for allergic reactions due to hymenoptera stings. The general response of the immune system to the ubiquitous exposure to N-glycan containing glycoproteins is still a matter of debate. CCD specific IgG antibodies in sera of bee keepers suggest tolerance induction due to high-dose exposure. Tolerance induction by pollen and food glycoproteins has not been proved. Hymenoptera stings and pollen exposure induce anti-CCD IgE. In regard to anaphylaxis due to Hymenoptera stings these antibodies are not clinically relevant, but they are important for the specificity of in-vitro tests proving insect venom allergy. The introduction of component based diagnostic IgE testing improves the specificity of in-vitro tests if proteins devoid of CCD epitopes are used.

  10. Chlorpyrifos PBPK/PD model for multiple routes of exposure.

    Science.gov (United States)

    Poet, Torka S; Timchalk, Charles; Hotchkiss, Jon A; Bartels, Michael J

    2014-10-01

    1. Chlorpyrifos (CPF) is an important pesticide used to control crop insects. Human Exposures to CPF will occur primarily through oral exposure to residues on foods. A physiologically based pharmacokinetic/pharmacodynamic (PBPK/PD) model has been developed that describes the relationship between oral, dermal and inhalation doses of CPF and key events in the pathway for cholinergic effects. The model was built on a prior oral model that addressed age-related changes in metabolism and physiology. This multi-route model was developed in rats and humans to validate all scenarios in a parallelogram design. 2. Critical biological effects from CPF exposure require metabolic activation to CPF oxon, and small amounts of metabolism in tissues will potentially have a great effect on pharmacokinetics and pharmacodynamic outcomes. Metabolism (bioactivation and detoxification) was therefore added in diaphragm, brain, lung and skin compartments. Pharmacokinetic data are available for controlled human exposures via the oral and dermal routes and from oral and inhalation studies in rats. The validated model was then used to determine relative dermal versus inhalation uptake from human volunteers exposed to CPF in an indoor scenario.

  11. [Optimization of process of icraiin be hydrolyzed to Baohuoside I by cellulase based on Plackett-Burman design combined with CCD response surface methodology].

    Science.gov (United States)

    Song, Chuan-xia; Chen, Hong-mei; Dai, Yu; Kang, Min; Hu, Jia; Deng, Yun

    2014-11-01

    To optimize the process of Icraiin be hydrolyzed to Baohuoside I by cellulase by Plackett-Burman design combined with Central Composite Design (CCD) response surface methodology. To select the main influencing factors by Plackett-Burman design, using CCD response surface methodology to optimize the process of Icraiin be hydrolyzed to Baohuoside I by cellulase. Taking substrate concentration, the pH of buffer and reaction time as independent variables, with conversion rate of icariin as dependent variable,using regression fitting of completely quadratic response surface between independent variable and dependent variable,the optimum process of Icraiin be hydrolyzed to Baohuoside I by cellulase was intuitively analyzed by 3D surface chart, and taking verification tests and predictive analysis. The best enzymatic hydrolytic process was as following: substrate concentration 8. 23 mg/mL, pH 5. 12 of buffer,reaction time 35. 34 h. The optimum process of Icraiin be hydrolyzed to Baohuoside I by cellulase is determined by Plackett-Burman design combined with CCD response surface methodology. The optimized enzymatic hydrolytic process is simple, convenient, accurate, reproducible and predictable.

  12. THE THIRD US NAVAL OBSERVATORY CCD ASTROGRAPH CATALOG (UCAC3)

    International Nuclear Information System (INIS)

    Zacharias, N.; Finch, C.; Wycoff, G.; Zacharias, M. I.; Corbin, T.; Dutta, S.; Gaume, R.; Gauss, S.; Hall, D.; Hartkopf, W.; Hsu, D.; Holdenried, E.; Makarov, V.; Mason, B.; Girard, T.; Hambly, N.; Castillo, D.; DiVittorio, M.; Germain, M.; Martines, M.

    2010-01-01

    The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3, was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with proper motions, covering about R = 8-16 mag. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrograph's 'red lens', equipped with a 4k x 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the southern hemisphere, the Yale/San Juan first epoch plates from the Southern Proper Motion (SPM) program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major differences of UCAC3 data as compared with UCAC2 include a completely new raw data reduction with improved control over systematic errors in positions, significantly improved photometry, slightly deeper limiting magnitude, coverage of the north pole region, greater completeness by inclusion of double stars, and weak detections. This of course leads to a catalog which is not as 'clean' as UCAC2 and problem areas are outlined for the user in this paper. The positional accuracy of stars in UCAC3 is about 15-100 mas per coordinate, depending on magnitude, while the errors in proper motions range from 1 to 10 mas yr -1 depending on magnitude and observing history, with a significant improvement over UCAC2 achieved due to the re-reduced SPM data and inclusion of more astrograph plate data unavailable at the time of UCAC2.

  13. A CCD-based search for very low mass members of the Pleiades cluster

    Science.gov (United States)

    Stauffer, John R.; Hamilton, Donald; Probst, Ronald G.

    1994-01-01

    We have obtained deep charge coupled device (CCD)V and I images of a number of fields near the center of the Pleiades open cluster. We have also obtained imaging data for Praesepe, a very similar cluster in terms of distance and richness but nearly 10 times older than the Pleiades. Because brown dwarfs are predicted to become much fainter and cooler between Pleiades and Praesepe ages, this provides a powerful differential technique for placing constraints on the brown dwarf population in open clusters. Combined with our previously reported observations, we now have data for about 0.4 sq deg in the Pleiades, corresponding roughly to 5% of the area of that cluster. We have searched the new CCD frames for additional Pleiades brown dwarf candidates. Two possible candidates are present, the faintest of which has V approximately equal to 22.5, (V-I)(sub K) approximately equal to 4.6. Because we do not have proper motion data and the colors of these objects are not redder than the reddest known field stars, it is possible that some or all of our candidates are somewhat higher mass field stars rather than Pleiades-age brown dwarfs. Even if all six of the proposed brown dwarf candidates in our 0.4 sq deg field are Pleiades members, the relatively small number found suggests that low mass stars or brown dwarfs do not contribute significantly to the total mass of the cluster.

  14. A directional fast neutron detector using scintillating fibers and an intensified CCD camera system

    International Nuclear Information System (INIS)

    Holslin, Daniel; Armstrong, A.W.; Hagan, William; Shreve, David; Smith, Scott

    1994-01-01

    We have been developing and testing a scintillating fiber detector (SFD) for use as a fast neutron sensor which can discriminate against neutrons entering at angles non-parallel to the fiber axis (''directionality''). The detector/convertor component is a fiber bundle constructed of plastic scintillating fibers each measuring 10 cm long and either 0.3 mm or 0.5 mm in diameter. Extensive Monte Carlo simulations were made to optimize the bundle response to a range of fast neutron energies and to intense fluxes of high energy gamma-rays. The bundle is coupled to a set of gamma-ray insenitive electro-optic intensifiers whose output is viewed by a CCD camera directly coupled to the intensifiers. Two types of CCD cameras were utilized: 1) a standard, interline RS-170 camera with electronic shuttering and 2) a high-speed (up to 850 frame/s) field-transfer camera. Measurements of the neutron detection efficiency and directionality were made using 14 MeV neutrons, and the response to gamma-rays was performed using intense fluxes from radioisotopic sources (up to 20 R/h). Recently, the detector was constructed and tested using a large 10 cm by 10 cm square fiber bundle coupled to a 10 cm diameter GEN I intensifier tube. We present a description of the various detector systems and report the results of experimental tests. ((orig.))

  15. A fast CCD detector for charge exchange recombination spectroscopy on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Thomas, D.M.; Burrell, K.H.; Groebner, R.J.; Gohil, P.

    1996-05-01

    Charge Exchange Recombination (CER) spectroscopy has become a standard diagnostic for tokamaks. CER measurements have been used to determine spatially and temporally resolved ion temperature, toroidal and poloidal ion rotation speed, impurity density and radial electric field. Knowledge of the spatial profile and temporal evolution of the electric field shear in the plasma edge is crucial to understanding the physics of the L to H transition. High speed CER measurements are also valuable for Edge Localized Mode (ELM) studies. Since the 0.52 ms minimum time resolution of our present system is barely adequate to study the time evolution of these phenomena, we have developed a new CCD detector system with about a factor of two better time resolution. In addition, our existing system detects sufficient photons to utilize the shortest time resolution only under exceptional conditions. The new CCD detector has a quantum efficiency of about 0.65, which is a factor of 7 better than our previous image intensifier-silicon photodiode detector systems. We have also equipped the new system with spectrometers of lower f/number. This combination should allow more routine operation at the minimum integration time, as well as improving data quality for measurements in the divertor-relevant region outside of the separatrix. Construction details, benchmark data and initial tokamak measurements for the new system will be presented

  16. Radiation exposure control by estimation of multiplication factors for online remote radiation monitoring systems at Vitrification Plant

    International Nuclear Information System (INIS)

    Deokar, Umesh V.; Kukarni, V.V.; Khot, A.R.; Mathew, P.; Kamlesh; Purohit, R.G.; Sarkar, P.K.

    2011-01-01

    Vitrification Plant is commissioned for vitrification of high-level liquid waste generated in Nuclear Fuel Cycle operations by using Joule Heated Ceramic Melter first time in India. Exposure control is a major concern in operating plant. Therefore, in addition to installed monitors, we have developed online remote radiation monitoring system to minimize number of entries in amber areas and to reduce the exposure to the surveyor and operator. This also helped in volume reduction of secondary waste. The reliability and accuracy of the online monitoring system is confirmed with actual measurements and by theoretical shielding calculations. The multiplication factors were estimated for remote online monitoring of Melter off Gas (MOG) filter, Hood filter, three exhaust filter banks, and overpack monitoring. This paper summarizes how the online remote monitoring system had helped in saving of 128.52 Person-mSv collective dose (14.28% of budgeted dose) and also there was 2.6 m 3 reduction in generation of Cat-I waste. (author)

  17. A VXI-based high speed x-ray CCD detector

    International Nuclear Information System (INIS)

    Huang, Qiang; Hopf, R.; Rodricks, B.

    1993-01-01

    For time-resolved x-ray scattering, one ideally wants a high speed detector that also is capable of giving position sensitive information. Charge Coupled Devices (CCDS) have been used successfully as x-ray detectors. Unfortunately, they are inherently slow because of the serial readout EEV has developed a CCD that has eight channels of parallel readout, thus increasing the speed eight fold. Using state-of-the-art VXI electronics, we have developed a readout system that could read the entire array in 2.5 ms using a 20-MHz readout clock. For testing and characterization the device was clocked at a significantly slower speed of 30 kHz. The data is preamplified and all eight channels of output are simultaneously digitized to 12 bits and stored in buffer memory. The system is controlled by a 486-based PC through an MXI bus and VXI controller using commercially available software. The system is also capable of real-time image display and manipulation

  18. White-light fringe detection based on a novel light source and colour CCD camera

    Czech Academy of Sciences Publication Activity Database

    Buchta, Zdeněk; Mikel, Břetislav; Lazar, Josef; Číp, Ondřej

    2011-01-01

    Roč. 22, č. 9 (2011), 094031:1-6 ISSN 0957-0233 R&D Projects: GA ČR GP102/09/P293; GA ČR GP102/09/P630; GA MPO 2A-1TP1/127; GA MŠk(CZ) LC06007; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : low-coherence interferometry * phase-crossing algorithm * CCD camera * gauge block Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.494, year: 2011

  19. Development of a programmable CCD detector for imaging, real time studies and other synchrotron radiation applications

    International Nuclear Information System (INIS)

    Brizard, C.

    1991-01-01

    A new CCD detector has been developed. The working of CCD and programmable detector is detailed in this thesis. The flexibility of the system allows the use of CCDs from different manufactures. The vacuum chamber of the detector is made of a beryllium window for experiments using X-radiation or of a quartz window coupled to a focusing optic system. Its temporal resolution is 2 microseconds with a X-radiation imaging. Images with a high spatial resolution have been obtained with the focusing system having a set of optical lenses and filters. The first X-ray diffraction experiments in the range of milliseconds and microseconds for the study of semiconductor heterostructures have been performed at X16 beam line at NSLS (National Synchrotron Light Source) with the detector illuminated by X-rays. For the first time, a X-ray beam, horizontally focused has been used to record a X-ray diffraction spectra on a 2-D detector. Finally, a X-ray diffraction method has been used to study the first steps of the crystallisation of Fe 8 0B 2 0 amorphous metallic alloy at X6 beam line at NSLS

  20. A new apparatus for track-analysis in nuclear track emulsion based on a CCD-camera device

    International Nuclear Information System (INIS)

    Ganssauge, E.

    1993-01-01

    A CCD camera-based, image-analyzing system for automatic evaluation of nuclear track emulsion chambers is presented. The stage of a normal microscope moves using three remote controlled stepping motors with a step size of 0.25 μm. A CCD-camera is mounted on tope of the microscope in order to register the nuclear emulsion. The camera has a resolution capable of differentiating single emulsion-grains (0.6 μm). The camera picture is transformed from analogue to digital signals and stored by a frame grabber. Some background-picture elements can be eliminated by applying cuts on grey levels. The central computer processes the picture, correlates the single picture points, the coordinates and the grey-levels, such that in the end one has a unique assignment of each picture point to an address on the hard disk for a given plate. After repetition of this procedure for several plates by means of an appropriate software (for instance our vertex program [1]). the coordinates of the points are combined to tracks, and a variety of distributions like pseudorapidity-distributions can be calculated and presented on the terminal. (author)

  1. The Pregnancy Exposome: Multiple Environmental Exposures in the INMA-Sabadell Birth Cohort.

    Science.gov (United States)

    Robinson, Oliver; Basagaña, Xavier; Agier, Lydiane; de Castro, Montserrat; Hernandez-Ferrer, Carles; Gonzalez, Juan R; Grimalt, Joan O; Nieuwenhuijsen, Mark; Sunyer, Jordi; Slama, Rémy; Vrijheid, Martine

    2015-09-01

    The "exposome" is defined as "the totality of human environmental exposures from conception onward, complementing the genome" and its holistic approach may advance understanding of disease etiology. We aimed to describe the correlation structure of the exposome during pregnancy to better understand the relationships between and within families of exposure and to develop analytical tools appropriate to exposome data. Estimates on 81 environmental exposures of current health concern were obtained for 728 women enrolled in The INMA (INfancia y Medio Ambiente) birth cohort, in Sabadell, Spain, using biomonitoring, geospatial modeling, remote sensors, and questionnaires. Pair-wise Pearson's and polychoric correlations were calculated and principal components were derived. The median absolute correlation across all exposures was 0.06 (5th-95th centiles, 0.01-0.54). There were strong levels of correlation within families of exposure (median = 0.45, 5th-95th centiles, 0.07-0.85). Nine exposures (11%) had a correlation higher than 0.5 with at least one exposure outside their exposure family. Effectively all the variance in the data set (99.5%) was explained by 40 principal components. Future exposome studies should interpret exposure effects in light of their correlations to other exposures. The weak to moderate correlation observed between exposure families will permit adjustment for confounding in future exposome studies.

  2. Multiple-endpoint assay provides a detailed mechanistic view of responses to herbicide exposure in Chlamydomonas reinhardtii

    International Nuclear Information System (INIS)

    Nestler, Holger; Groh, Ksenia J.; Schönenberger, René; Behra, Renata; Schirmer, Kristin; Eggen, Rik I.L.; Suter, Marc J.-F.

    2012-01-01

    The release of herbicides into the aquatic environment raises concerns about potential detrimental effects on ecologically important non-target species, such as unicellular algae, necessitating ecotoxicological risk assessment. Algal toxicity tests based on growth, a commonly assessed endpoint, are integrative, and hence do not provide information about underlying toxic mechanisms and effects. This limitation may be overcome by measuring more specific biochemical and physiological endpoints. In the present work, we developed and applied a novel multiple-endpoint assay, and analyzed the effects of the herbicides paraquat, diuron and norflurazon, each representing a specific mechanism of toxic action, on the single celled green alga Chlamydomonas reinhardtii. The endpoints added to assessment of growth were pigment content, maximum and effective photosystem II quantum yield, ATP content, esterase and oxidative activity. All parameters were measured at 2, 6 and 24 h of exposure, except for growth and pigment content, which were determined after 6 and 24 h only. Effective concentrations causing 50% of response (EC50s) and lowest observable effect concentrations (LOECs) were determined for all endpoints and exposure durations where possible. The assay provided a detailed picture of the concentration- and time-dependent development of effects elicited by the analyzed herbicides, thus improving the understanding of the underlying toxic mechanisms. Furthermore, the response patterns were unique to the respective herbicide and reflected the different mechanisms of toxicity. The comparison of the endpoint responses and sensitivities revealed that several physiological and biochemical parameters reacted earlier or stronger to disturbances than growth. Overall, the presented multiple-endpoint assay constitutes a promising basis for investigating stressor and toxicant effects in green algae.

  3. Multiple-endpoint assay provides a detailed mechanistic view of responses to herbicide exposure in Chlamydomonas reinhardtii

    Energy Technology Data Exchange (ETDEWEB)

    Nestler, Holger [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); Groh, Ksenia J.; Schoenenberger, Rene; Behra, Renata [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); Schirmer, Kristin [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); EPF Lausanne, School of Architecture, Civil and Environmental Engineering, 1015 Lausanne (Switzerland); Eggen, Rik I.L. [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); Suter, Marc J.-F., E-mail: suter@eawag.ch [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland)

    2012-04-15

    The release of herbicides into the aquatic environment raises concerns about potential detrimental effects on ecologically important non-target species, such as unicellular algae, necessitating ecotoxicological risk assessment. Algal toxicity tests based on growth, a commonly assessed endpoint, are integrative, and hence do not provide information about underlying toxic mechanisms and effects. This limitation may be overcome by measuring more specific biochemical and physiological endpoints. In the present work, we developed and applied a novel multiple-endpoint assay, and analyzed the effects of the herbicides paraquat, diuron and norflurazon, each representing a specific mechanism of toxic action, on the single celled green alga Chlamydomonas reinhardtii. The endpoints added to assessment of growth were pigment content, maximum and effective photosystem II quantum yield, ATP content, esterase and oxidative activity. All parameters were measured at 2, 6 and 24 h of exposure, except for growth and pigment content, which were determined after 6 and 24 h only. Effective concentrations causing 50% of response (EC50s) and lowest observable effect concentrations (LOECs) were determined for all endpoints and exposure durations where possible. The assay provided a detailed picture of the concentration- and time-dependent development of effects elicited by the analyzed herbicides, thus improving the understanding of the underlying toxic mechanisms. Furthermore, the response patterns were unique to the respective herbicide and reflected the different mechanisms of toxicity. The comparison of the endpoint responses and sensitivities revealed that several physiological and biochemical parameters reacted earlier or stronger to disturbances than growth. Overall, the presented multiple-endpoint assay constitutes a promising basis for investigating stressor and toxicant effects in green algae.

  4. Measurement of charge of heavy ions in emulsion using a CCD camera

    CERN Document Server

    Kudzia, D; Dabrowska, A; Deines-Jones, P; Holynski, R; Olszewski, A; Nilsen, B S; Sen-Gupta, K; Szarska, M; Trzupek, A; Waddington, C J; Wefel, J P; Wilczynska, B; Wilczynski, H; Wolter, W; Wosiek, B; Wozniak, K

    1999-01-01

    A system has been developed for semi-automated determination of the charges of heavy ions recorded in nuclear emulsions. The profiles of various heavy ion tracks in emulsion, both accelerator beam ions and fragments of heavy projectiles, were obtained with a CCD camera mounted on a microscope. The dependence of track profiles on illumination, emulsion grain size and density, background in emulsion, and track geometry was analyzed. Charges of the fragments of heavy projectiles were estimated independently by the delta ray counting method. A calibration of both width and height of track profiles against ion charges was made with ions of known charges ranging from helium to gold nuclei. (author)

  5. Viability evaluation of the reading system by CCD for application at the Fricke xylenol gel dosimetry developed by IPEN-Sao Paulo, Brazil; Avaliacao de viabilidade do sistema de leitura por CCD para aplicacao na dosimetria Fricke xilenol gel desenvolvido no IPEN-Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Mangueira, Thyago Fressatti; Dias, Daniel Menezes; Campos, Leticia Lucente, E-mail: thyagomangueira@usp.b, E-mail: dmdias@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    The use of chambers with coupled charge devices - CCD, is already used by research centres for the dose evaluation applying the Fricke xylenol gel dosemeter. This work evaluates the application of this optical reading technique for the FXG developed at the IPEN, Sao Paulo, Brazil

  6. CCD photometry of the distant young open cluster NGC 7510

    International Nuclear Information System (INIS)

    Sagar, R.; Bonn Univ.; Griffiths, W.K.

    1991-01-01

    CCD observations in B, V and I passbands have been used to generate deep V, (B-V) and V,(V-I) colour-magnitude diagrams for the open cluster NGC 7510. The sample consists of 592 stars reaching down to V=21 mag. There appears to be non-uniform extinction over the face of the cluster with the value of colour excess, E(B-V), ranging from 1.0 to 1.3 mag. The law of interstellar extinction in the direction of the cluster is found to be normal. A broad main sequence is clearly visible in both colour-magnitude diagrams. From the bluest part of the colour-magnitude diagrams, the true distance modulus to the cluster has been estimated as 12.5±0.3 mag and an upper limit of 10 Myr has been assigned for the cluster age. (author)

  7. The OmegaCAM 16K x 16K CCD detector system for the ESO VLT Survey Telescope (VST)

    Science.gov (United States)

    Iwert, Olaf; Baade, D.; Balestra, A.; Baruffolo, A.; Bortolussi, A.; Christen, F.; Cumani, C.; Deiries, S.; Downing, M.; Geimer, C.; Hess, G.; Hess, J.; Kuijken, K.; Lizon, J.; Muschielok, B.; Nicklas, H.; Reiss, R.; Reyes, J.; Silber, A.; Thillerup, J.; Valentijn, E.

    2006-06-01

    A 16K x 16K, 1 degree x 1 degree field, detector system was developed by ESO for the OmegaCAM instrument for use on the purpose built ESO VLT Survey Telescope (VST). The focal plane consists of an 8 x 4 mosaic of 2K x 4K 15um pixel e2v CCDs and four 2K x 4K CCDs on the periphery for the opto-mechanical control of the telescope. The VST is a single instrument telescope. This placed stringent reliability requirements on the OmegaCAM detector system such as 10 years lifetime and maximum downtime of 1.5 %. Mounting at Cassegrain focus required a highly autonomous self-contained cooling system that could deliver 65 W of cooling power. Interface space for the detector head was severely limited by the way the instrument encloses the CCD cryostat. The detector system features several novel ideas tailored to meet these requirements and described in this paper: Key design drivers of the detector head were the easily separable but precisely aligned connections to the optical field flattener on the top and the cooling system at the bottom. Material selection, surface treatment, specialized coatings and in-situ plasma cleaning were crucial to prevent contamination of the detectors. Inside the cryostat, cryogenic and electrical connections were disentangled to keep the configuration modular, integration friendly and the detectors in a safe condition during all mounting steps. A compact unit for logging up to 125 Pt100 temperature sensors and associated thermal control loops was developed (ESO's new housekeeping unit PULPO 2), together with several new modular Pt100 packaging and mounting concepts. The electrical grouping of CCDs based on process parameters and test results is explained. Three ESO standardized FIERA CCD controllers in different configurations are used. Their synchronization mechanism for read-out is discussed in connection with the CCD grouping scheme, the shutter, and the integrated guiding and image analysis facility with four independent 2K x 4K CCDs. An

  8. Skin Pigmentation Kinetics after Exposure to Ultraviolet A

    DEFF Research Database (Denmark)

    Ravnbak, M.H.; Philipsen, P.A.; Wiegell, S.R.

    2009-01-01

    Multiple exposures to ultraviolet radiation (UVR) are the norm in nature and phototherapy. However, studies of the kinetics of pigmentation following UVA exposure have included only fair-skinned persons. The aim of this study was to investigate steady-state pigmentation and fading in 12 Scandinav......Multiple exposures to ultraviolet radiation (UVR) are the norm in nature and phototherapy. However, studies of the kinetics of pigmentation following UVA exposure have included only fair-skinned persons. The aim of this study was to investigate steady-state pigmentation and fading in 12...... Scandinavians and 12 Indians/Pakistanis after 6 and 12 exposures on the back using broadband UVA and UVA1 with equal sub-minimal melanogenic doses (individually predetermined). Pigmentation was measured by skin reflectance at 555 and 660 urn. The UV dose to minimal pigmentation was higher in dark......-skinned persons after a single broadband UVA exposure, but independent of pigmentation/skin type after single and multiple UVA1 exposures. To elicit minimal melanogenic doses after 6 and 12 exposures, every dose is lowered by a factor of 2 and 3, respectively, but the cumulative dose increases three- and four...

  9. Development of Cell Phone Application for Blood Glucose Self-Monitoring Based on ISO/IEEE 11073 and HL7 CCD.

    Science.gov (United States)

    Park, Hyun Sang; Cho, Hune; Kim, Hwa Sun

    2015-04-01

    The objectives of this research were to develop and evaluate a cell phone application based on the standard protocol for personal health devices and the standard information model for personal health records to support effective blood glucose management and standardized service for patients with diabetes. An application was developed for Android 4.0.3. In addition, an IEEE 11073 Manager, Medical Device Encoding Rule, and Bluetooth Health Device Profile Connector were developed for standardized health communication with a glucometer, and a Continuity of Care Document (CCD) Composer and CCD Parser were developed for CCD document exchange. The developed application was evaluated by five healthcare professionals and 87 users through a questionnaire comprising the following variables: usage intention, effort expectancy, social influence, facilitating condition, perceived risk, and voluntariness. As a result of the evaluation of usability, it was confirmed that the developed application is useful for blood glucose self-monitoring by diabetic patients. In particular, the healthcare professionals stated their own views that the application is useful to observe the trends in blood glucose change through the automatic function which records a blood glucose level measured using Bluetooth function, and the function which checks accumulated records of blood glucose levels. Also, a result of the evaluation of usage intention was 3.52 ± 0.42 out of 5 points. The application developed by our research team was confirmed by the verification of healthcare professionals that accurate feedback can be provided to healthcare professionals during the management of diabetic patients or education for glucose management.

  10. PUBLIC EXPOSURE TO MULTIPLE RF SOURCES IN GHANA.

    Science.gov (United States)

    Deatanyah, P; Abavare, E K K; Menyeh, A; Amoako, J K

    2018-03-16

    This paper describes an effort to respond to the suggestion in World Health Organization (WHO) research agenda to better quantify potential exposure levels from a range of radiofrequency (RF) sources at 200 public access locations in Ghana. Wide-band measurements were performed-with a spectrum analyser and a log-periodic antenna using three-point spatial averaging method. The overall results represented a maximum of 0.19% of the ICNIRP reference levels for public exposure. These results were generally lower than found in some previous but were 58% (2.0 dB) greater, than found in similar work conducted in the USA. Major contributing sources of RF fields were identified to be FM broadcast and mobile base station sites. Three locations with the greatest measured RF fields could represent potential areas for epidemiological studies.

  11. CCD photometry in the Vilnius photometric systems. II. Analysis of a region in Lyra

    International Nuclear Information System (INIS)

    Smriglio, F.; Dasgupta, A.K.; Boyle, R.P.; Straizys, V.; Janulis, R.

    1991-01-01

    Two-dimensional classification of 216 stars down to 17 mag based on their seven color photoelectric and CCD photometry in the Vilnius system is presented. Except for normal stars, several subdwarfs, metal-deficient giants, and stars of other peculiarities are suspected. Interstellar extinction is determined for normal stars in two areas north and south of globular cluster M56, as well as for a 1 square degree area around M56. The mean value of A v outside the galactic dust layer is ∼ 0.75 mag

  12. BV RI CCD photometry of 361,281 objects in the field of M 31

    Science.gov (United States)

    Magnier, E. A.; Lewin, W. H. G.; Van Paradijs, J.; Hasinger, G.; Jain, A.; Pietsch, W.; Truemper, J.

    1992-01-01

    Deep BV RI CCD photometry was performed on a 1 sq deg region of M 31. A catalog of photometry and astrometry of a total of 361,281 stars is presented, with typical completion limits of BV RI = (22.3, 22.2, 22.2, 20.9). Photometric accuracy is about 2 percent at V = 19. This catalog allows detailed studies of stellar populations and reddening. The data are currently being used to assist in finding the optical counterparts of Einstein and ROSAT X-ray sources.

  13. Colony collapse disorder: a descriptive study.

    Directory of Open Access Journals (Sweden)

    Dennis Vanengelsdorp

    Full Text Available BACKGROUND: Over the last two winters, there have been large-scale, unexplained losses of managed honey bee (Apis mellifera L. colonies in the United States. In the absence of a known cause, this syndrome was named Colony Collapse Disorder (CCD because the main trait was a rapid loss of adult worker bees. We initiated a descriptive epizootiological study in order to better characterize CCD and compare risk factor exposure between populations afflicted by and not afflicted by CCD. METHODS AND PRINCIPAL FINDINGS: Of 61 quantified variables (including adult bee physiology, pathogen loads, and pesticide levels, no single measure emerged as a most-likely cause of CCD. Bees in CCD colonies had higher pathogen loads and were co-infected with a greater number of pathogens than control populations, suggesting either an increased exposure to pathogens or a reduced resistance of bees toward pathogens. Levels of the synthetic acaricide coumaphos (used by beekeepers to control the parasitic mite Varroa destructor were higher in control colonies than CCD-affected colonies. CONCLUSIONS/SIGNIFICANCE: This is the first comprehensive survey of CCD-affected bee populations that suggests CCD involves an interaction between pathogens and other stress factors. We present evidence that this condition is contagious or the result of exposure to a common risk factor. Potentially important areas for future hypothesis-driven research, including the possible legacy effect of mite parasitism and the role of honey bee resistance to pesticides, are highlighted.

  14. Investigation on HL-1M pellet shape and cloud structure

    International Nuclear Information System (INIS)

    Zheng Yinjia

    2001-01-01

    When hydrogen multi-pellet flied out from the gun exit and was injected into the HL-1M plasma, the pellet injection and ablation cloud were observed by using a 2D CCD camera SensiCam 360LF. The shape of flight pellet from the gun exit was obtained with the photos taken. The pellet ablation process and the structure of its cloud were analyzed by means of photos with multiple exposure (exp. 100 ns) and long exposure. The experimental setup is described, the results of the pellet injection experiment and characteristic of ablation cloud are presented

  15. CCD-camera-based diffuse optical tomography to study ischemic stroke in preclinical rat models

    Science.gov (United States)

    Lin, Zi-Jing; Niu, Haijing; Liu, Yueming; Su, Jianzhong; Liu, Hanli

    2011-02-01

    Stroke, due to ischemia or hemorrhage, is the neurological deficit of cerebrovasculature and is the third leading cause of death in the United States. More than 80 percent of stroke patients are ischemic stroke due to blockage of artery in the brain by thrombosis or arterial embolism. Hence, development of an imaging technique to image or monitor the cerebral ischemia and effect of anti-stoke therapy is more than necessary. Near infrared (NIR) optical tomographic technique has a great potential to be utilized as a non-invasive image tool (due to its low cost and portability) to image the embedded abnormal tissue, such as a dysfunctional area caused by ischemia. Moreover, NIR tomographic techniques have been successively demonstrated in the studies of cerebro-vascular hemodynamics and brain injury. As compared to a fiberbased diffuse optical tomographic system, a CCD-camera-based system is more suitable for pre-clinical animal studies due to its simpler setup and lower cost. In this study, we have utilized the CCD-camera-based technique to image the embedded inclusions based on tissue-phantom experimental data. Then, we are able to obtain good reconstructed images by two recently developed algorithms: (1) depth compensation algorithm (DCA) and (2) globally convergent method (GCM). In this study, we will demonstrate the volumetric tomographic reconstructed results taken from tissuephantom; the latter has a great potential to determine and monitor the effect of anti-stroke therapies.

  16. The Relationship Between and Factors Influencing Staff Nurses' Perceptions of Nurse Manager Caring and Exposure to Workplace Bullying in Multiple Healthcare Settings.

    Science.gov (United States)

    Olender, Lynda

    2017-10-01

    The aim of this study was to examine the relationship between, and factors influencing, staff nurse perceptions of nurse manager caring (NMC) and the perceived exposure to workplace bullying (WPB) in multiple healthcare settings. Workplace bullying is commonplace, increasing, and detrimental to the health and availability of our nursing workforce. Positive relationships between a nurse manager (NM) and staff increase staff satisfaction and reduce turnover. Still unknown, however, is whether a caring relationship between manager and staff can reduce staff nurse perception of exposure to WPB. On the basis of Watson's theory that caring is reciprocal in nature, a descriptive correlational design was used to assess 156 staff nurses' self-report of NMC and their exposure to negative acts using the Caring Factor Survey-Caring of the Manager and the Negative Acts Questionnaire-Revised instruments. There is a significant inverse relationship between NMC and exposure to WPB in the nursing workplace. Gender, work environment, and a high workload influenced these findings. This study highlights the importance of caring leadership to reduce exposure to negative behaviors. The data lend support to the idea of educating NMs regarding the application of caring behaviors to support staff at the point of care.

  17. The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor

    International Nuclear Information System (INIS)

    Suzuki, Yosuke; Matsumoto, Nobue; Morita, Hiroshi; Ohkawa, Hiromitsu

    1998-01-01

    The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor was examined and its correction was investigated. CDR was adopted in this study and evaluated image quality, by measuring MTF. The oblique projection was clinically permissible to about an oblique incident angle of 40 degrees although it exerts an influence on the magnifying power and density. The estimation of the oblique entrance direction and oblique incident angle was possible, by developing an oblique incident correction marker. When an oblique incident angle of θ degrees was measured, a correction is possible, by compressing the image cos (θ) times perpendicular to the rotational axis of CCD sensor. There was small decline of MTF, in the image where a correction for the influence of oblique incidence was made. By observation of the digital subtracted picture of the image after correction of oblique projection and that of normal, the resemblance in the two images indicated that this correction method was reasonable. (author)

  18. Laboratory simulation of Euclid-like sky images to study the impact of CCD radiation damage on weak gravitational lensing

    Science.gov (United States)

    Prod'homme, T.; Verhoeve, P.; Oosterbroek, T.; Boudin, N.; Short, A.; Kohley, R.

    2014-07-01

    Euclid is the ESA mission to map the geometry of the dark universe. It uses weak gravitational lensing, which requires the accurate measurement of galaxy shapes over a large area in the sky. Radiation damage in the 36 Charge-Coupled Devices (CCDs) composing the Euclid visible imager focal plane has already been identified as a major contributor to the weak-lensing error budget; radiation-induced charge transfer inefficiency (CTI) distorts the galaxy images and introduces a bias in the galaxy shape measurement. We designed a laboratory experiment to project Euclid-like sky images onto an irradiated Euclid CCD. In this way - and for the first time - we are able to directly assess the effect of CTI on the Euclid weak-lensing measurement free of modelling uncertainties. We present here the experiment concept, setup, and first results. The results of such an experiment provide test data critical to refine models, design and test the Euclid data processing CTI mitigation scheme, and further optimize the Euclid CCD operation.

  19. The SMILE Soft X-ray Imager (SXI) CCD design and development

    Science.gov (United States)

    Soman, M. R.; Hall, D. J.; Holland, A. D.; Burgon, R.; Buggey, T.; Skottfelt, J.; Sembay, S.; Drumm, P.; Thornhill, J.; Read, A.; Sykes, J.; Walton, D.; Branduardi-Raymont, G.; Kennedy, T.; Raab, W.; Verhoeve, P.; Agnolon, D.; Woffinden, C.

    2018-01-01

    SMILE, the Solar wind Magnetosphere Ionosphere Link Explorer, is a joint science mission between the European Space Agency and the Chinese Academy of Sciences. The spacecraft will be uniquely equipped to study the interaction between the Earth's magnetosphere-ionosphere system and the solar wind on a global scale. SMILE's instruments will explore this science through imaging of the solar wind charge exchange soft X-ray emission from the dayside magnetosheath, simultaneous imaging of the UV northern aurora and in-situ monitoring of the solar wind and magnetosheath plasma and magnetic field conditions. The Soft X-ray Imager (SXI) is the instrument being designed to observe X-ray photons emitted by the solar wind charge exchange process at photon energies between 200 eV and 2000 eV . X-rays will be collected using a focal plane array of two custom-designed CCDs, each consisting of 18 μm square pixels in a 4510 by 4510 array. SMILE will be placed in a highly elliptical polar orbit, passing in and out of the Earth's radiation belts every 48 hours. Radiation damage accumulated in the CCDs during the mission's nominal 3-year lifetime will degrade their performance (such as through decreases in charge transfer efficiency), negatively impacting the instrument's ability to detect low energy X-rays incident on the regions of the CCD image area furthest from the detector outputs. The design of the SMILE-SXI CCDs is presented here, including features and operating methods for mitigating the effects of radiation damage and expected end of life CCD performance. Measurements with a PLATO device that has not been designed for soft X-ray signal levels indicate a temperature-dependent transfer efficiency performance varying between 5×10-5 and 9×10-4 at expected End of Life for 5.9 keV photons, giving an initial set of measurements from which to extrapolate the performance of the SXI CCDs.

  20. CCD photometry in the Vilnius photometric systems. II. Analysis of a region in Lyra

    Energy Technology Data Exchange (ETDEWEB)

    Smriglio, F.; Dasgupta, A.K. (Rome Univ. (IT). Ist. Astronomico); Nandy, K. (Royal Observatory, Edinburgh (UK)); Boyle, R.P. (Vatican Observatory, Rome (IT)); Straizys, V.; Janulis, R. (AN Litovskoj SSR, Vilnius (SU). Inst. Fiziki)

    1991-04-01

    Two-dimensional classification of 216 stars down to 17 mag based on their seven color photoelectric and CCD photometry in the Vilnius system is presented. Except for normal stars, several subdwarfs, metal-deficient giants, and stars of other peculiarities are suspected. Interstellar extinction is determined for normal stars in two areas north and south of globular cluster M56, as well as for a 1 square degree area around M56. The mean value of A{sub v} outside the galactic dust layer is {similar to} 0.75 mag.

  1. CCD photometry in the Vilnius photometric system. I. region in Lyra

    International Nuclear Information System (INIS)

    Boyle, R.P.; Smriglio, F.; Straizys, V.

    1990-01-01

    Three-dimensional photometric classification can be made for stars measured in the Vilnius seven-color intermediate-band system, even if they are reddened by dust. Such classification is important for questions relating to the structure and evolution of our Galaxy. Presented here for general use is CCD photometry of 231 field stars in Lyra observed with the 0.9 meter telescope of Kitt Peak National Observatory. The measurements are of higher accuracy than those of a photographic study in the same direction in Lyra for which they can also be used for a deeper calibration of the photographic photometry. The data sets cover two small fields each about 31 arcmin 2 and are complete to 90% for all stars up to the faint limit of V = 17.5

  2. Measuring neutron fluences and gamma/x-ray fluxes with CCD cameras

    International Nuclear Information System (INIS)

    Yates, G.J.; Smith, G.W.; Zagarino, P.; Thomas, M.C.

    1991-01-01

    Volume and area measurements of transient radiation-induced pixel charge in English Electric Valve (EEV) Frame Transfer (FT) charge coupled devices (CCDs) from irradiation with pulsed neutrons (14 MeV) and Bremsstrahlung photons (16-MeV endpoint) are utilized to calibrate the devices as radiometric imaging sensors capable of distinguishing between the two types of ionizing radiation. Measurements indicate ∼0.5 V/rad responsivity with ≥1 rad required for saturation from photon irradiation. Neutron-generated localized charge centers or ''peaks'' binned by area and amplitude as functions of fluence in the 10 5 to 10 7 n/cm 2 range indicate smearing over ∼1 to 10% of CCD array with charge per pixel ranging between noise and saturation levels. 9 refs., 12 figs., 4 tabs

  3. The Natural-CCD Algorithm, a Novel Method to Solve the Inverse Kinematics of Hyper-redundant and Soft Robots.

    Science.gov (United States)

    Martín, Andrés; Barrientos, Antonio; Del Cerro, Jaime

    2018-03-22

    This article presents a new method to solve the inverse kinematics problem of hyper-redundant and soft manipulators. From an engineering perspective, this kind of robots are underdetermined systems. Therefore, they exhibit an infinite number of solutions for the inverse kinematics problem, and to choose the best one can be a great challenge. A new algorithm based on the cyclic coordinate descent (CCD) and named as natural-CCD is proposed to solve this issue. It takes its name as a result of generating very harmonious robot movements and trajectories that also appear in nature, such as the golden spiral. In addition, it has been applied to perform continuous trajectories, to develop whole-body movements, to analyze motion planning in complex environments, and to study fault tolerance, even for both prismatic and rotational joints. The proposed algorithm is very simple, precise, and computationally efficient. It works for robots either in two or three spatial dimensions and handles a large amount of degrees-of-freedom. Because of this, it is aimed to break down barriers between discrete hyper-redundant and continuum soft robots.

  4. Improving quantum efficiency and spectral resolution of a CCD through direct manipulation of the depletion region

    Science.gov (United States)

    Brown, Craig; Ambrosi, Richard M.; Abbey, Tony; Godet, Olivier; O'Brien, R.; Turner, M. J. L.; Holland, Andrew; Pool, Peter J.; Burt, David; Vernon, David

    2008-07-01

    Future generations of X-ray astronomy instruments will require position sensitive detectors in the form of charge-coupled devices (CCDs) for X-ray spectroscopy and imaging with the ability to probe the X-ray universe with greater efficiency. This will require the development of CCDs with structures that will improve their quantum efficiency over the current state of the art. The quantum efficiency improvements would have to span a broad energy range (0.2 keV to >15 keV). These devices will also have to be designed to withstand the harsh radiation environments associated with orbits that extend beyond the Earth's magnetosphere. This study outlines the most recent work carried out at the University of Leicester focused on improving the quantum efficiency of an X-ray sensitive CCD through direct manipulation of the device depletion region. It is also shown that increased spectral resolution is achieved using this method due to a decrease in the number of multi-pixel events. A Monte Carlo and analytical models of the CCD have been developed and used to determine the depletion depths achieved through variation of the device substrate voltage, Vss. The models are also used to investigate multi-pixel event distributions and quantum efficiency as a function of depletion depth.

  5. Deep CCD photometry in globular clusters. VII. M30

    International Nuclear Information System (INIS)

    Richer, H.B.; Fahlman, G.G.; Vandenberg, D.A.

    1988-01-01

    New UBV CCD photometry in a single field of the globular cluster M30 was obtained, and the data were used to obtain the color magnitude diagram (CMD) of the cluster, its luminosity function, and to derive fundamental cluster parameters. No blue stragglers were found, nor any evidence of a binary sequence in the data even though the field under study is only 21 core radii from the cluster center. The cluster reddening is observed to be 0.068 + or - 0.035, significantly higher than that adopted in most current papers on M30. An intercomparison of the CMDs of three very metal-poor clusters clearly shows that there is no evidence for any age difference between them. The age of M30 itself is found to be about 14 Gyr. The luminosity function of M30 is determined to be M(V) = 8. Comparison of this function with one found by Bolte (1987) at 65 core radii shows clear evidence of mass segregation in the low-mass stars. 44 references

  6. Upgrade of ESO's FIERA CCD Controller and PULPO Subsystem

    Science.gov (United States)

    Reyes-Moreno, J.; Geimer, C.; Balestra, A.; Haddad, N.

    An overview of FIERA is presented with emphasis on its recent upgrade to PCI. The PCI board hosts two DSPs, one for real time control of the camera and another for on-the-fly processing of the incoming video data. In addition, the board is able to make DMA transfers, to synchronize to other boards alike, to be synchronized by a TIM bus and to control PULPO via RS232. The design is based on the IOP480 chip from PLX, for which we have developed a device driver for both Solaris and Linux. One computer is able to host more than one board and therefore can control an array of FIERA detector electronics. PULPO is a multifunctional subsystem widely used at ESO for the housekeeping of CCD cryostat heads and for shutter control. The upgrade of PULPO is based on an embedded PC running Linux. The upgraded PULPO is able to handle 29 temperature sensors, control 8 heaters and one shutter, read out one vacuum sensor and log any combination of parameters.

  7. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  8. Narrative exposure therapy: an evidence-based treatment for multiple and complex trauma

    Directory of Open Access Journals (Sweden)

    Ruud A. Jongedijk

    2014-12-01

    Full Text Available Narrative exposure therapy (NET is a recently developed, short-term treatment for patients with a posttraumatic stress disorder (PTSD as a result of multiple trauma. NET can be applied very successfully in patients with complex trauma complaints (Jongedijk, 2014; Schauer, Neuner, & Elbert, 2011.An important feature of NET is that trauma processing is never an isolated event but is always embedded in the context of a traumatic event and in the life history as a whole. At the start, the lifeline is laid. The lifeline is made up of a rope, with flowers (happy events, stones (traumatic events, sometimes candles (grief, or recently also sticks for aggressive acts (NET for offenders; see Stenmark, Cuneyt Guzey, Elbert, & Holen, 2014. These symbols are laid down along the rope, in chronological order. Subsequently, in the subsequent therapy sessions the lifeline is processed in chronological order, giving attention to all the important events a person has experienced in his or her life, both the adverse as well as the pleasurable ones. The narration ends with a written testimony.To date, there is good evidence NET is effective in the treatment of PTSD patients, with support from 18 RCTs (N=950. For culturally diverse populations, NET is recommended as the most evidence-based trauma treatment, besides culturally adapted CBT. NET has been investigated in different populations in Africa, Europe, and Asia. In Asia, research has been carried out in Sri Lanka as well as in China. In China, NET was conducted and investigated with survivors of the Sichuan earthquake (Zang, Hunt, & Cox, 2013, 2014. NET is understandable, even appealing and also supportive for patients with multiple trauma. In this presentation, the treatment principles and the practice of NET will be explained.

  9. Dose-Response for Multiple Biomarkers of Exposure and Genotoxic Effect Following Repeated Treatment of Rats with the Alkylating Agents, MMS and MNU.

    Science.gov (United States)

    Ji, Zhiying; LeBaron, Matthew J; Schisler, Melissa R; Zhang, Fagen; Bartels, Michael J; Gollapudi, B Bhaskar; Pottenger, Lynn H

    2016-05-01

    The nature of the dose-response relationship for various in vivo endpoints of exposure and effect were investigated using the alkylating agents, methyl methanesulfonate (MMS) and methylnitrosourea (MNU). Six male F344 rats/group were dosed orally with 0, 0.5, 1, 5, 25 or 50mg/kg bw/day (mkd) of MMS, or 0, 0.01, 0.1, 1, 5, 10, 25 or 50 mkd of MNU, for 4 consecutive days and sacrificed 24h after the last dose. The dose-responses for multiple biomarkers of exposure and genotoxic effect were investigated. In MMS-treated rats, the hemoglobin adduct level, a systemic exposure biomarker, increased linearly with dose (r (2) = 0.9990, P agents. © The Author 2015. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Method to implement the CCD timing generator based on FPGA

    Science.gov (United States)

    Li, Binhua; Song, Qian; He, Chun; Jin, Jianhui; He, Lin

    2010-07-01

    With the advance of the PFPA technology, the design methodology of digital systems is changing. In recent years we develop a method to implement the CCD timing generator based on FPGA and VHDL. This paper presents the principles and implementation skills of the method. Taking a developed camera as an example, we introduce the structure, input and output clocks/signals of a timing generator implemented in the camera. The generator is composed of a top module and a bottom module. The bottom one is made up of 4 sub-modules which correspond to 4 different operation modes. The modules are implemented by 5 VHDL programs. Frame charts of the architecture of these programs are shown in the paper. We also describe implementation steps of the timing generator in Quartus II, and the interconnections between the generator and a Nios soft core processor which is the controller of this generator. Some test results are presented in the end.

  11. Study of 'Redhaven' peach and its white-fleshed mutant suggests a key role of CCD4 carotenoid dioxygenase in carotenoid and norisoprenoid volatile metabolism

    Directory of Open Access Journals (Sweden)

    Tartarini Stefano

    2011-01-01

    Full Text Available Abstract Background Carotenoids are plant metabolites which are not only essential in photosynthesis but also important quality factors in determining the pigmentation and aroma of flowers and fruits. To investigate the regulation of carotenoid metabolism, as related to norisoprenoids and other volatile compounds in peach (Prunus persica L. Batsch., and the role of carotenoid dioxygenases in determining differences in flesh color phenotype and volatile composition, the expression patterns of relevant carotenoid genes and metabolites were studied during fruit development along with volatile compound content. Two contrasted cultivars, the yellow-fleshed 'Redhaven' (RH and its white-fleshed mutant 'Redhaven Bianca' (RHB were examined. Results The two genotypes displayed marked differences in the accumulation of carotenoid pigments in mesocarp tissues. Lower carotenoid levels and higher levels of norisoprenoid volatiles were observed in RHB, which might be explained by differential activity of carotenoid cleavage dioxygenase (CCD enzymes. In fact, the ccd4 transcript levels were dramatically higher at late ripening stages in RHB with respect to RH. The two genotypes also showed differences in the expression patterns of several carotenoid and isoprenoid transcripts, compatible with a feed-back regulation of these transcripts. Abamine SG - an inhibitor of CCD enzymes - decreased the levels of both isoprenoid and non-isoprenoid volatiles in RHB fruits, indicating a complex regulation of volatile production. Conclusions Differential expression of ccd4 is likely to be the major determinant in the accumulation of carotenoids and carotenoid-derived volatiles in peach fruit flesh. More in general, dioxygenases appear to be key factors controlling volatile composition in peach fruit, since abamine SG-treated 'Redhaven Bianca' fruits had strongly reduced levels of norisoprenoids and other volatile classes. Comparative functional studies of peach carotenoid

  12. VizieR Online Data Catalog: CCD Hα and R photometry of 334 galaxies (James+, 2004)

    Science.gov (United States)

    James, P. A.; Shane, N. S.; Beckman, J. E.; Cardwell, A.; Collins, C. A.; Etherton, J.; de Jong, R. S.; Fathi, K.; Knapen, J. H.; Peletier, R. F.; Percival, S. M.; Pollacco, D. L.; Seigar, M. S.; Stedman, S.; Steele, I. A.

    2004-01-01

    Hα plus [NII] and R-band CCD photometry and derived parameters are presented for the full sample of 334 spiral and irregular galaxies. Galaxy distances are derived using a Virgo-infall corrected model which is described in the paper, and star formation rates are derived from Hα plus [NII] fluxes using the conversion defined by Kennicutt et al. (1994ApJ...435...22K). The entries are arranged within five bins in recession velocity, and in order of increasing Right Ascension within these bins. (1 data file).

  13. Ultra-accelerated natural sunlight exposure testing

    Science.gov (United States)

    Jorgensen, Gary J.; Bingham, Carl; Goggin, Rita; Lewandowski, Allan A.; Netter, Judy C.

    2000-06-13

    Process and apparatus for providing ultra accelerated natural sunlight exposure testing of samples under controlled weathering without introducing unrealistic failure mechanisms in exposed materials and without breaking reciprocity relationships between flux exposure levels and cumulative dose that includes multiple concurrent levels of temperature and relative humidity at high levels of natural sunlight comprising: a) concentrating solar flux uniformly; b) directing the controlled uniform sunlight onto sample materials in a chamber enclosing multiple concurrent levels of temperature and relative humidity to allow the sample materials to be subjected to accelerated irradiance exposure factors for a sufficient period of time in days to provide a corresponding time of about at least a years worth of representative weathering of the sample materials.

  14. The multiple stressor effect in zebrafish embryos from simultaneous exposure to ionising radiation and cadmium

    International Nuclear Information System (INIS)

    Ng, C Y P; Choi, V W Y; Lam, A C L; Yu, K N; Cheng, S H

    2013-01-01

    Living organisms are exposed to a mixture of environmental stressors, and the resultant effects are referred to as multiple stressor effects. In the present work, we studied the multiple stressor effect in embryos of the zebrafish (Danio rerio) from simultaneous exposure to ionising radiation (alpha particles) and cadmium through quantification of apoptotic signals at 24 h postfertilisation (hpf) revealed by vital dye acridine orange staining. For each set of experiments, 32–40 dechorionated embryos were deployed, which were divided into four groups each having 8–10 embryos. The four groups of embryos were referred to as (1) the control group (C), which received no further treatments after dechorionation; (2) the Cd-dosed and irradiated group (CdIr), which was exposed to 100 μM Cd from 5 to 24 hpf, and also received about 4.4 mGy from alpha particles at 5 hpf; (3) the irradiated group (Ir), which received about 4.4 mGy from alpha particles at 5 hpf; and (4) the Cd-dosed group (Cd), which was exposed to 100 μM Cd from 5 to 24 hpf. In general, the CdIr, Ir and Cd groups had more apoptotic signals than the C group. Within the 12 sets of experimental results, two showed significant synergistic effects, one showed a weakly synergistic effect and nine showed additive effects. The multiple stressor effect of 100 μM Cd with ∼4.4 mGy alpha-particle radiation resulted in an additive or synergistic effect, but no antagonistic effect. The failure to identify significant synergistic effects for some sets of data, and thus their subsequent classification as additive effects, might be a result of the relatively small magnitude of the synergistic effects. The results showed that the radiation risk could be perturbed by another environmental stressor such as a heavy metal, and as such a realistic human radiation risk assessment should in general take into account the multiple stressor effects. (paper)

  15. Multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Tran, Marie Thi Dao; Arendt-Nielsen, Lars; Kupers, Ron

    2013-01-01

    BACKGROUND: Multiple Chemical Sensitivity (MCS) is a chronic condition characterized by recurrent, non-specific symptoms in response to chemically unrelated exposures in non-toxic concentrations. Although the pathophysiology of MCS remains unknown, central sensitization may be an important factor...

  16. [Accumulative effects and long-term persistence of subliminal mere exposure].

    Science.gov (United States)

    Kawakami, Naoaki; Yoshida, Fujio

    2011-10-01

    We examined the accumulative effects and long-term persistence of subliminal mere exposure. An accumulative exposure condition (100 exposures distributed over five days) and a massed exposure condition (100 exposures in one day) were used in a Go/No-go Association Task (GNAT), with assessments of likability from Time 1 (just after) to Time 6 (after three months). First, a single stimulus was shown subliminally for a total of 100 times. The results indicated that mere exposure effects occurred equally often at Time 1. However, after Time 2, likability gradually decreased under the massed exposure condition, while it did not decrease under the accumulative exposure condition until Time 6. Second, in order to investigate the effect of multiple exposure, five stimuli belonging to a common category were shown 20 times each, for a total of 100 times. An ANOVA suggested that massed exposure had an instantaneous effect on likability, whereas accumulative exposure had a long-term persistence effect. Also, multiple exposures strengthened the mere exposure effect.

  17. A multiple endpoint analysis of the effects of chronic exposure to sediment contaminated with Deepwater Horizon oil on juvenile Southern flounder and their associated microbiomes

    International Nuclear Information System (INIS)

    Brown-Peterson, Nancy J.; Krasnec, Michelle; Takeshita, Ryan; Ryan, Caitlin N.; Griffitt, Kimberly J.; Lay, Claire; Mayer, Gregory D.; Bayha, Keith M.; Hawkins, William E.; Lipton, Ian; Morris, Jeffrey

    2015-01-01

    Highlights: • Juvenile southern flounder were exposed to sediment mixed with different amount of oil from the Deepwater Horizon spill. • The exposure was performed for 32 days, with growth and survival assessed throughout. • After the termination of the experiment, the survivors were examined at multiple endpoints, including histopathology and microbiome analysis. • The results indicated that the flounder were adversely affected at each endpoint examined. • Growth and survival were significantly reduced. • Histopathology found effects on gills and livers of exposed fish. • The microbiomes of the exposed fish were significantly altered by the exposure to sediment-associated oil in both gills and intestines. - Abstract: Exposure to oiled sediments can negatively impact the health of fish species. Here, we examine the effects of chronic exposure of juvenile southern flounder, Paralichthys lethostigma, to a sediment-oil mixture. Oil:sediment mixtures are persistent over time and can become bioavailable following sediment perturbation or resuspension. Juvenile flounder were exposed for 32 days under controlled laboratory conditions to five concentrations of naturally weathered Macondo MC252 oil mixed into uncontaminated, field-collected sediments. The percent composition of individual polycyclic aromatic hydrocarbons (PAHs) of the weathered oil did not change after mixing with the sediment. Spiked exposure sediments contained 0.04–395 mg/kg tPAH50 (sum of 50 individual PAH concentration measurements). Mortality increased with both exposure duration and concentration of sediment-associated PAHs, and flounder exposed to concentrations above 8 mg/kg tPAH50 showed significantly reduced growth over the course of the experiment. Evident histopathologic changes were observed in liver and gill tissues of fish exposed to more than 8 mg/kg tPAH50. All fish at these concentrations showed hepatic intravascular congestion, macrovesicular hepatic vacoulation

  18. A multiple endpoint analysis of the effects of chronic exposure to sediment contaminated with Deepwater Horizon oil on juvenile Southern flounder and their associated microbiomes

    Energy Technology Data Exchange (ETDEWEB)

    Brown-Peterson, Nancy J., E-mail: nancy.brown-peterson@usm.edu [Department of Coastal Sciences, The University of Southern Mississippi, 703 East Beach Dr., Ocean Springs, MS 39564 (United States); Krasnec, Michelle, E-mail: MKrasnec@stratusconsulting.com [Abt Associates, 1881 Ninth Street, Suite 201, Boulder, Colorado 80302 (United States); Takeshita, Ryan, E-mail: RTakeshita@stratusconsulting.com [Abt Associates, 1881 Ninth Street, Suite 201, Boulder, Colorado 80302 (United States); Ryan, Caitlin N., E-mail: Caitlin.ryan@ttu.edu [The Institute of Environmental and Human Health, Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409 (United States); Griffitt, Kimberly J., E-mail: kim.griffitt@gmail.com [Department of Coastal Sciences, The University of Southern Mississippi, 703 East Beach Dr., Ocean Springs, MS 39564 (United States); Lay, Claire, E-mail: claymsc@stratusconsulting.com [Abt Associates, 1881 Ninth Street, Suite 201, Boulder, Colorado 80302 (United States); Mayer, Gregory D., E-mail: greg.mayer@ttu.edu [The Institute of Environmental and Human Health, Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409 (United States); Bayha, Keith M., E-mail: kmbayha@gmail.com [Department of Coastal Sciences, The University of Southern Mississippi, 703 East Beach Dr., Ocean Springs, MS 39564 (United States); Hawkins, William E., E-mail: william.hawkins@usm.edu [Department of Coastal Sciences, The University of Southern Mississippi, 703 East Beach Dr., Ocean Springs, MS 39564 (United States); Lipton, Ian, E-mail: ianlipton@stratusconsulting.com [Abt Associates, 1881 Ninth Street, Suite 201, Boulder, Colorado 80302 (United States); Morris, Jeffrey, E-mail: JMorrisMSCanyon252@stratusconsulting.com [Abt Associates, 1881 Ninth Street, Suite 201, Boulder, Colorado 80302 (United States); and others

    2015-08-15

    Highlights: • Juvenile southern flounder were exposed to sediment mixed with different amount of oil from the Deepwater Horizon spill. • The exposure was performed for 32 days, with growth and survival assessed throughout. • After the termination of the experiment, the survivors were examined at multiple endpoints, including histopathology and microbiome analysis. • The results indicated that the flounder were adversely affected at each endpoint examined. • Growth and survival were significantly reduced. • Histopathology found effects on gills and livers of exposed fish. • The microbiomes of the exposed fish were significantly altered by the exposure to sediment-associated oil in both gills and intestines. - Abstract: Exposure to oiled sediments can negatively impact the health of fish species. Here, we examine the effects of chronic exposure of juvenile southern flounder, Paralichthys lethostigma, to a sediment-oil mixture. Oil:sediment mixtures are persistent over time and can become bioavailable following sediment perturbation or resuspension. Juvenile flounder were exposed for 32 days under controlled laboratory conditions to five concentrations of naturally weathered Macondo MC252 oil mixed into uncontaminated, field-collected sediments. The percent composition of individual polycyclic aromatic hydrocarbons (PAHs) of the weathered oil did not change after mixing with the sediment. Spiked exposure sediments contained 0.04–395 mg/kg tPAH50 (sum of 50 individual PAH concentration measurements). Mortality increased with both exposure duration and concentration of sediment-associated PAHs, and flounder exposed to concentrations above 8 mg/kg tPAH50 showed significantly reduced growth over the course of the experiment. Evident histopathologic changes were observed in liver and gill tissues of fish exposed to more than 8 mg/kg tPAH50. All fish at these concentrations showed hepatic intravascular congestion, macrovesicular hepatic vacoulation

  19. Radiation exposure control by estimation of multiplication factors for online remote radiation monitoring systems at vitrification plant

    International Nuclear Information System (INIS)

    Deokar, U.V.; Kulkarni, V.V.; Khot, A.R.; Mathew, P.; Kamlesh; Purohit, R.G.; Sarkar, P.K.

    2012-01-01

    Vitrification Plant is commissioned for vitrification of high level liquid waste (HLW) generated in nuclear fuel cycle operations by using Joule Heated Ceramic Melter first time in India. Exposure control is a major concern in operating plant. Therefore in addition to installed monitors, we have developed online remote radiation monitoring system to minimize number of entries in amber areas and to reduce the exposure to the surveyor and operator. This also helped in volume reduction of secondary waste. The reliability and accuracy of the online monitoring system is confirmed with actual measurements and by theoretical shielding calculations. The multiplication factors were estimated for remote on line monitoring of Melter Off Gas (MOG) filter, Hood filter, three exhaust filter banks, and over-pack monitoring. This paper summarizes - how the online remote monitoring system helped in saving of 128.52 person-mSv collective dose (14.28% of budgeted dose). The system also helped in the reduction of 2.6 m 3 of Cat-I waste. Our online remote monitoring system has helped the plant management to plan in advance for replacement of these filters, which resulted in considerable saving in collective dose and secondary waste

  20. A new method of CCD dark current correction via extracting the dark Information from scientific images

    Science.gov (United States)

    Ma, Bin; Shang, Zhaohui; Hu, Yi; Liu, Qiang; Wang, Lifan; Wei, Peng

    2014-07-01

    We have developed a new method to correct dark current at relatively high temperatures for Charge-Coupled Device (CCD) images when dark frames cannot be obtained on the telescope. For images taken with the Antarctic Survey Telescopes (AST3) in 2012, due to the low cooling efficiency, the median CCD temperature was -46°C, resulting in a high dark current level of about 3e-/pix/sec, even comparable to the sky brightness (10e-/pix/sec). If not corrected, the nonuniformity of the dark current could even overweight the photon noise of the sky background. However, dark frames could not be obtained during the observing season because the camera was operated in frame-transfer mode without a shutter, and the telescope was unattended in winter. Here we present an alternative, but simple and effective method to derive the dark current frame from the scientific images. Then we can scale this dark frame to the temperature at which the scientific images were taken, and apply the dark frame corrections to the scientific images. We have applied this method to the AST3 data, and demonstrated that it can reduce the noise to a level roughly as low as the photon noise of the sky brightness, solving the high noise problem and improving the photometric precision. This method will also be helpful for other projects that suffer from similar issues.

  1. Registers of multiple sclerosis in Denmark

    DEFF Research Database (Denmark)

    Koch-Henriksen, N; Magyari, M; Laursen, B

    2015-01-01

    between a number of different environmental exposures in the past and the subsequent risk of MS. Some of these studies have been able to exonerate suspected risk factors. The other register, the nationwide Danish Multiple Sclerosis Treatment Register, is a follow-up register for all patients who have......There are two nationwide population-based registers for multiple sclerosis (MS) in Denmark. The oldest register is The Danish Multiple Sclerosis Registry (DMSR), which is an epidemiological register for estimation of prevalence and incidence of MS and survival, and for identifying exposures earlier...... received disease-modifying treatments since 1996. It has, in particular, contributed to the knowledge of the role of antibodies against the biological drugs used for the treatment of MS....

  2. Applications of an energy-dispersive pnCCD for X-ray reflectivity: Investigation of interdiffusion in Fe-Pt multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Abboud, Ali; Send, Sebastian; Pietsch, Ullrich [Universitaet Siegen, FB Physik, Walter-Flex-Strasse 3, 57072 Siegen (Germany); Hartmann, Robert [PNSensor GmbH, Muenchen (Germany); Strueder, Lothar [Universitaet Siegen, FB Physik, Walter-Flex-Strasse 3, 57072 Siegen (Germany); Planck-Institut fuer extraterrestrische Physik (MPE), Muenchen (Germany); MPI Halbleiterlabor, Muenchen (Germany); Savan, Alan; Ludwig, Alfred [Ruhr-Universitaet Bochum, Bochum (Germany); Zotov, Nikolay [Forschungszentrum Juelich, Juelich (Germany)

    2011-11-15

    A frame store pn-junction CCD (pnCCD) detector was applied to study thermally induced interdiffusion in Fe/Pt thin film multilayers (MLs) in a temperature range between 300 and 585 K. Based on the energy resolution of the detector the reflectivity was measured simultaneously in a spectral range between 8 keV < E < 20 keV including the Pt L-edge energies close to 11.5 keV. Above T = 533 K we find a strong drop of intensities at 1st and 2nd order ML Bragg peak interpreted by mutual interdiffusion. Considering a simulated model of interdiffusion it has been found that the concentration of iron that diffuses into the platinum sub layers is higher than that of platinum into iron. The time dependence of inter diffusion was also calculated in the range of 533-568 K and was described by the Arrhenius equation D(T) = D{sub 0} exp(-H{sub a}/k{sub B}T). The activation energy for the MLs used [Fe 1.7 nm/Pt 2 nm]{sub 50} was found to be 0.94 {+-} 0.22 eV. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Lipid Adjustment for Chemical Exposures: Accounting for Concomitant Variables

    Science.gov (United States)

    Li, Daniel; Longnecker, Matthew P.; Dunson, David B.

    2013-01-01

    Background Some environmental chemical exposures are lipophilic and need to be adjusted by serum lipid levels before data analyses. There are currently various strategies that attempt to account for this problem, but all have their drawbacks. To address such concerns, we propose a new method that uses Box-Cox transformations and a simple Bayesian hierarchical model to adjust for lipophilic chemical exposures. Methods We compared our Box-Cox method to existing methods. We ran simulation studies in which increasing levels of lipid-adjusted chemical exposure did and did not increase the odds of having a disease, and we looked at both single-exposure and multiple-exposures cases. We also analyzed an epidemiology dataset that examined the effects of various chemical exposures on the risk of birth defects. Results Compared with existing methods, our Box-Cox method produced unbiased estimates, good coverage, similar power, and lower type-I error rates. This was the case in both single- and multiple-exposure simulation studies. Results from analysis of the birth-defect data differed from results using existing methods. Conclusion Our Box-Cox method is a novel and intuitive way to account for the lipophilic nature of certain chemical exposures. It addresses some of the problems with existing methods, is easily extendable to multiple exposures, and can be used in any analyses that involve concomitant variables. PMID:24051893

  4. Radiotherapy film densitometry using a slow-scan, cooled, digital CCD imaging system

    International Nuclear Information System (INIS)

    Burch, S.E.

    1993-01-01

    A method of performing high-resolution two-dimensional film densitometry for full size radiographic film (35 x 43 cm) using a cooled CCD camera was proposed. Studies were performed to evaluate the physical characteristics of the camera system and recommendations were made to assure maximum accuracy of density measurement. Test films of various sizes and densities, as well as clinical dosimetry films, were measured with the CCD densitometer and the reference transmission densitometer. The measured densities agreed within the stated accuracy of the transmission densitometer for all films with maximum density less than or equal to 1.5 optical density units. The 0.2 mm spatial resolution with 4096 shades of gray made it possible to study dose distributions even for films containing areas of high dose gradients. Patient verification radiographs were used to study exit beam dose distributions to detect errors in beam placement, patient position, and proper placement of beam modifying devices such as wedges and compensators. For studying photon beam dose distributions within phantoms, a method was developed using lead foils placed lateral to the film plane to filter very low energy scattered photons. The error in measurement of central axis percentage depth dose from film for 4 MV x-rays, 25 x 25 cm field was decreased from 65% to 4%. The method requires only two calibration films for density to dose conversion and represents an important advance in the field of film densitometry for radiotherapy. The technique was applied to the study of dynamic wedge dose distribution from a 6 MV linear accelerator. The phantom modification decreased the error in percentage depth dose from 21% to 1% for the 15 x 15 cm beam with 60 degree wedge angle. Profile off-axis errors for the same beam were decreased from 8% to 3%. The film dosimetry system provides fast, high resolution film density data for use in radiotherapy imaging and quality assurance

  5. A study on characteristics of X-ray detector for CCD-based EPID

    International Nuclear Information System (INIS)

    Chung, Yong Hyun

    1999-02-01

    The combination of the metal plate/phosphor screen as a x-ray detector with a CCD camera is the most popular detector system among various electronic portal imaging devices (EPIDs). There is a need to optimize the thickness of the metal plate/phosphor screen with high detection efficiency and high spatial resolution for effective transferring of anatomical information. In this study, the thickness dependency on the detection efficiency and the spatial resolution of the metal plate/phosphor screen was investigated by calculation and measurement. The result can be used to determine the optimal thickness of the metal plate as well as of the phosphor screen for the x-ray detector design of therapeutic x-ray imaging and for any specific application. Bremsstrahlung spectrum was calculated by Monte Carlo simulation and by Schiff formula. The detection efficiency was calculated from the total absorbed energy in the phosphor screen using the Monte Carlo simulation and the light output was measured. The spatial resolution, which was defined from the spatial distribution of the absorbed energy, was also calculated and the edge spread function was measured. It was found that the detection efficiency and the spatial resolution were mainly determined by the thickness of metal plate and phosphor screen, respectively. It was also revealed that the detection efficiency and the spatial resolution have trade-off in term of the thickness of the phosphor screen. As the phosphor thickness increases, the detection efficiency increases but the spatial resolution decreases. The curve illustrating the trade-off between the detection efficiency and the spatial resolution of the metal plate/phosphor screen detector is obtained as a function of the phosphor thickness. Based on the calculations, prototype CCD-based EPID was developed and then tested by acquiring phantom images for 6 MV x-ray beam. While, among the captured images, each frame suffered from quantum noise, the frame averaging

  6. Measuring the Flatness of Focal Plane for Very Large Mosaic CCD Camera

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Jiangang; Estrada, Juan; Cease, Herman; Diehl, H.Thomas; Flaugher, Brenna L.; Kubik, Donna; Kuk, Keivin; Kuropatkine, Nickolai; Lin, Huan; Montes, Jorge; Scarpine, Vic; /Fermilab

    2010-06-08

    Large mosaic multiCCD camera is the key instrument for modern digital sky survey. DECam is an extremely red sensitive 520 Megapixel camera designed for the incoming Dark Energy Survey (DES). It is consist of sixty two 4k x 2k and twelve 2k x 2k 250-micron thick fully-depleted CCDs, with a focal plane of 44 cm in diameter and a field of view of 2.2 square degree. It will be attached to the Blanco 4-meter telescope at CTIO. The DES will cover 5000 square-degrees of the southern galactic cap in 5 color bands (g, r, i, z, Y) in 5 years starting from 2011. To achieve the science goal of constraining the Dark Energy evolution, stringent requirements are laid down for the design of DECam. Among them, the flatness of the focal plane needs to be controlled within a 60-micron envelope in order to achieve the specified PSF variation limit. It is very challenging to measure the flatness of the focal plane to such precision when it is placed in a high vacuum dewar at 173 K. We developed two image based techniques to measure the flatness of the focal plane. By imaging a regular grid of dots on the focal plane, the CCD offset along the optical axis is converted to the variation the grid spacings at different positions on the focal plane. After extracting the patterns and comparing the change in spacings, we can measure the flatness to high precision. In method 1, the regular dots are kept in high sub micron precision and cover the whole focal plane. In method 2, no high precision for the grid is required. Instead, we use a precise XY stage moves the pattern across the whole focal plane and comparing the variations of the spacing when it is imaged by different CCDs. Simulation and real measurements show that the two methods work very well for our purpose, and are in good agreement with the direct optical measurements.

  7. Deep CCD photometry in globular clusters III. M15

    International Nuclear Information System (INIS)

    Fahlman, G.G.; Richer, H.B.; Vandenberg, D.A.

    1985-01-01

    CCD photometry in U, B, and V is presented for a 5' x 3' field in the globular cluster M15. The location of the main sequence in the color-magnitude diagram is found here to be significantly bluer than previous studies have indicated. The luminosity function of the cluster is studied down to V = 22.8 (Mroughly-equal7.5) and shown to be consistent with a power-law mass function, n(M) = QM/sup -alpha/ with α = 2.5 +- 1.0, to the limit of our data. The field star population brighter than V = 21.5, is examined in some detail. There appears to be about 50% more stars belonging to the disk in the field as compared with the Bahcall-Soneira standard galaxy model. The reddening to the cluster is found to be E(B-V) = 0.11 +- 0.04 from nine bright field stars. A new value for the ultraviolet excess of the cluster main-sequence stars is obtained, delta(0.6) = 0.25 +- 0.02, and confirms the well-known fact that M15 is among the metal poorest of the globular clusters

  8. CCD Parallaxes for 309 Late-type Dwarfs and Subdwarfs

    Energy Technology Data Exchange (ETDEWEB)

    Dahn, Conard C.; Harris, Hugh C.; Subasavage, John P.; Ables, Harold D.; Guetter, Harry H.; Harris, Fred H.; Luginbuhl, Christian B.; Monet, Alice B.; Monet, David G.; Munn, Jeffrey A.; Pier, Jeffrey R.; Stone, Ronald C.; Vrba, Frederick J.; Walker, Richard L.; Tilleman, Trudy M. [US Naval Observatory, Flagstaff Station, 10391 W. Naval Observatory Road, Flagstaff, AZ 86005-8521 (United States); Canzian, Blaise J. [L-3 Communications/Brashear, 615 Epsilon Drive, Pittsburgh, PA 15238-2807 (United States); Henden, Arne H. [AAVSO, Cambridge, MA 02138 (United States); Leggett, S. K. [Gemini Observatory, Northern Operations Center, 670 N. A’ohoku Place, Hilo, HI 96720 (United States); Levine, Stephen E., E-mail: jsubasavage@nofs.navy.mil [Lowell Observatory, 1400 W. Mars Hill Road, Flagstaff, AZ 86001-4499 (United States)

    2017-10-01

    New, updated, and/or revised CCD parallaxes determined with the Strand Astrometric Reflector at the Naval Observatory Flagstaff Station are presented. Included are results for 309 late-type dwarf and subdwarf stars observed over the 30+ years that the program operated. For 124 of the stars, parallax determinations from other investigators have already appeared in the literature and we compare the different results. Also included here are new or updated VI photometry on the Johnson–Kron-Cousins system for all but a few of the faintest targets. Together with 2MASS JHK{sub s} near-infrared photometry, a sample of absolute magnitude versus color and color versus color diagrams are constructed. Because large proper motion was a prime criterion for targeting the stars, the majority turn out to be either M-type subdwarfs or late M-type dwarfs. The sample also includes 50 dwarf or subdwarf L-type stars, and four T dwarfs. Possible halo subdwarfs are identified in the sample based on tangential velocity, subluminosity, and spectral type. Residuals from the solutions for parallax and proper motion for several stars show evidence of astrometric perturbations.

  9. BVI CCD photometry of the broad main-sequence globular cluster NGC 1851

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.; Wenderoth, E.

    1990-01-01

    Three-color CCD C-M diagrams are presented for the globular cluster NGC 1851, showing an extreme breadth of the main-sequence, similar to that of Omega Centauri. It is found that the main-sequence turnoff points are located at V(TO) = 19.44 + or - 0.10, with colors at B-V = 0.54 + or - 0.02, V-I = 0.61 + or - 0.02, and B-I = 1.15 + or - 0.03. The best fit to the VandenBerg and Bell (1985) isochrones is shown to be all C-M diagrams with Y = 0.20, Fe/H abundance ratio = -1.27, and (m-M)v = 15.45. It is concluded that NGC 1851 has a Delta V(TO - HB) = 3.34 + or - 0.10 and an age of 16 + or - 2 Gyr. 29 refs

  10. Pulsed X-ray radiography of a gas jet target for laser-matter interaction experiments with the use of a CCD detector

    International Nuclear Information System (INIS)

    Rakowski, R.; Bartnik, A.; Fiedorowicz, H.; Jarocki, R.; Kostecki, J.; MikoIajczyk, J.; Szczurek, A.; Szczurek, M.; Foeldes, I.B.; Toth, Zs.

    2005-01-01

    Characterization of gas jet targets has been carried out using pulsed X-ray radiography. A laser-plasma X-ray source was applied for backlighting of the targets to obtain X-ray shadowgraphs registered with a CCD detector. From the shadowgraphs, characteristics of the targets were determined

  11. Assessing human variability in kinetics for exposures to multiple environmental chemicals: a physiologically based pharmacokinetic modeling case study with dichloromethane, benzene, toluene, ethylbenzene, and m-xylene.

    Science.gov (United States)

    Valcke, Mathieu; Haddad, Sami

    2015-01-01

    The objective of this study was to compare the magnitude of interindividual variability in internal dose for inhalation exposure to single versus multiple chemicals. Physiologically based pharmacokinetic models for adults (AD), neonates (NEO), toddlers (TODD), and pregnant women (PW) were used to simulate inhalation exposure to "low" (RfC-like) or "high" (AEGL-like) air concentrations of benzene (Bz) or dichloromethane (DCM), along with various levels of toluene alone or toluene with ethylbenzene and xylene. Monte Carlo simulations were performed and distributions of relevant internal dose metrics of either Bz or DCM were computed. Area under the blood concentration of parent compound versus time curve (AUC)-based variability in AD, TODD, and PW rose for Bz when concomitant "low" exposure to mixtures of increasing complexities occurred (coefficient of variation (CV) = 16-24%, vs. 12-15% for Bz alone), but remained unchanged considering DCM. Conversely, AUC-based CV in NEO fell (15 to 5% for Bz; 12 to 6% for DCM). Comparable trends were observed considering production of metabolites (AMET), except for NEO's CYP2E1-mediated metabolites of Bz, where an increased CV was observed (20 to 71%). For "high" exposure scenarios, Cmax-based variability of Bz and DCM remained unchanged in AD and PW, but decreased in NEO (CV= 11-16% to 2-6%) and TODD (CV= 12-13% to 7-9%). Conversely, AMET-based variability for both substrates rose in every subpopulation. This study analyzed for the first time the impact of multiple exposures on interindividual variability in toxicokinetics. Evidence indicates that this impact depends upon chemical concentrations and biochemical properties, as well as the subpopulation and internal dose metrics considered.

  12. Low-dose radiation pretreatment improves survival of human ceiling culture-derived proliferative adipocytes (ccdPAs) under hypoxia via HIF-1 alpha and MMP-2 induction

    International Nuclear Information System (INIS)

    Adachi, Naoki; Kubota, Yoshitaka; Kosaka, Kentarou; Akita, Shinsuke; Sasahara, Yoshitarou; Kira, Tomoe; Kuroda, Masayuki; Mitsukawa, Nobuyuki; Bujo, Hideaki; Satoh, Kaneshige

    2015-01-01

    Poor survival is a major problem of adipocyte transplantation. We previously reported that VEGF and MMPs secreted from transplanted adipocytes are essential for angiogenesis and adipogenesis. Pretreatment with low-dose (5 Gy) radiation (LDR) increased VEGF, MMP-2, and HIF-1 alpha mRNA expression in human ceiling culture-derived proliferative adipocytes (hccdPAs). Gene expression after LDR differed between adipose-derived stem cells (hASCs) and hccdPAs. Pretreatment with LDR improved the survival of hccdPAs under hypoxia, which is inevitable in the early stages after transplantation. Upregulation of VEGF and MMP-2 after LDR in hccdPAs is mediated by HIF-1 alpha expression. Our results suggest that pretreatment with LDR may improve adipocyte graft survival in a clinical setting through upregulation of VEGF and MMP-2 via HIF-1 alpha. - Highlights: • Ceiling culture-derived proliferative adipocytes (ccdPAs) react to radiation. • Low-dose radiation (LDR) pretreatment improves survival of ccdPAs under hypoxia. • Gene expression after LDR differs between ccdPAs and adipose-derived stem cells. • LDR-induced increase in MMP-2 and VEGF is dependent on HIF-1 alpha induction. • LDR pretreatment may improve the adipocyte graft survival rate in clinical settings

  13. Low-dose radiation pretreatment improves survival of human ceiling culture-derived proliferative adipocytes (ccdPAs) under hypoxia via HIF-1 alpha and MMP-2 induction

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Naoki [Department of Plastic Surgery, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan); Kubota, Yoshitaka, E-mail: kubota-cbu@umin.ac.jp [Department of Plastic Surgery, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan); Kosaka, Kentarou; Akita, Shinsuke; Sasahara, Yoshitarou; Kira, Tomoe [Department of Plastic Surgery, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan); Kuroda, Masayuki [Center for Advanced Medicine, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan); Mitsukawa, Nobuyuki [Department of Plastic Surgery, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan); Bujo, Hideaki [Department of Clinical-Laboratory and Experimental-Research Medicine, Toho University, Sakura Medical Center, 564-1 Shimoshizu, Sakura-shi, Chiba, #285-8741 (Japan); Satoh, Kaneshige [Department of Plastic Surgery, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba-city, Chiba, #260-8677 (Japan)

    2015-08-07

    Poor survival is a major problem of adipocyte transplantation. We previously reported that VEGF and MMPs secreted from transplanted adipocytes are essential for angiogenesis and adipogenesis. Pretreatment with low-dose (5 Gy) radiation (LDR) increased VEGF, MMP-2, and HIF-1 alpha mRNA expression in human ceiling culture-derived proliferative adipocytes (hccdPAs). Gene expression after LDR differed between adipose-derived stem cells (hASCs) and hccdPAs. Pretreatment with LDR improved the survival of hccdPAs under hypoxia, which is inevitable in the early stages after transplantation. Upregulation of VEGF and MMP-2 after LDR in hccdPAs is mediated by HIF-1 alpha expression. Our results suggest that pretreatment with LDR may improve adipocyte graft survival in a clinical setting through upregulation of VEGF and MMP-2 via HIF-1 alpha. - Highlights: • Ceiling culture-derived proliferative adipocytes (ccdPAs) react to radiation. • Low-dose radiation (LDR) pretreatment improves survival of ccdPAs under hypoxia. • Gene expression after LDR differs between ccdPAs and adipose-derived stem cells. • LDR-induced increase in MMP-2 and VEGF is dependent on HIF-1 alpha induction. • LDR pretreatment may improve the adipocyte graft survival rate in clinical settings.

  14. Decreased vaccine antibody titers following exposure to multiple metals and metalloids in e-waste-exposed preschool children.

    Science.gov (United States)

    Lin, Xinjiang; Xu, Xijin; Zeng, Xiang; Xu, Long; Zeng, Zhijun; Huo, Xia

    2017-01-01

    We explored acquired immunity resulting from vaccination in 3 to 7-year-old children, chronically exposed to multiple heavy metals and metalloids, in an e-waste recycling area (Guiyu, China). Child blood levels of ten heavy metals and metalloids, including lead (Pb), arsenic (As), mercury (Hg), chromium (Cr), cadmium (Cd), manganese (Mn), nickel (Ni), copper (Cu), zinc (Zn) and selenium (Se), and seven vaccine antibodies (diphtheria, pertussis, tetanus, hepatitis B, Japanese encephalitis, polio, measles) were measured. The exposed group had higher levels of blood Pb, Mn, Cu, Zn and Cr compared to the reference group (P 10 μg/dL) and high blood Cu and Zn (upper median value of each group) to be inversely associated with seven antibody titers. Antibody titers increased with age, BMI, high blood Mn (>15 μg/L), and high blood Cd and Ni (upper median value of each group). Results suggest multiple heavy metal and metalloid exposure, especially to Pb, Zn and Cu, may be a risk factor inhibiting the development of child immunity, resulting in decreased child antibody levels against vaccines. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Optimum color filters for CCD digital cameras

    Science.gov (United States)

    Engelhardt, Kai; Kunz, Rino E.; Seitz, Peter; Brunner, Harald; Knop, Karl

    1993-12-01

    As part of the ESPRIT II project No. 2103 (MASCOT) a high performance prototype color CCD still video camera was developed. Intended for professional usage such as in the graphic arts, the camera provides a maximum resolution of 3k X 3k full color pixels. A high colorimetric performance was achieved through specially designed dielectric filters and optimized matrixing. The color transformation was obtained by computer simulation of the camera system and non-linear optimization which minimized the perceivable color errors as measured in the 1976 CIELUV uniform color space for a set of about 200 carefully selected test colors. The color filters were designed to allow perfect colorimetric reproduction in principle and at the same time with imperceptible color noise and with special attention to fabrication tolerances. The camera system includes a special real-time digital color processor which carries out the color transformation. The transformation can be selected from a set of sixteen matrices optimized for different illuminants and output devices. Because the actual filter design was based on slightly incorrect data the prototype camera showed a mean colorimetric error of 2.7 j.n.d. (CIELUV) in experiments. Using correct input data in the redesign of the filters, a mean colorimetric error of only 1 j.n.d. (CIELUV) seems to be feasible, implying that it is possible with such an optimized color camera to achieve such a high colorimetric performance that the reproduced colors in an image cannot be distinguished from the original colors in a scene, even in direct comparison.

  16. Calibration of the photometric method of heavy ion charge measurements in emulsion using a CCD camera

    International Nuclear Information System (INIS)

    Kudzia, D.; Wilczynska, B.; Wilczynski, H.

    2002-01-01

    A previously developed method of heavy ion charge measurements in emulsion has been significantly improved. The charge measurements are based on analysis of photometric profiles of the particle tracks in emulsion. These profiles are obtained using a CCD camera mounted on an optical microscope. So far, the manual charge determination by delta ray counting had to be used for calibration of the photometric method. In this paper a complete procedure for calibration of the photometric method is shown, without resorting to the manual method

  17. Exposure Plus Response-Prevention Treatment of Bulimia Nervosa.

    Science.gov (United States)

    Leitenberg, Harold; And Others

    1988-01-01

    Evaluated exposure plus response-prevention treatment of bulimia nervosa among 47 women. Subjects were assigned to either exposure plus response-prevention in one setting, exposure plus response-prevention in multiple settings, cognitive-behavioral therapy, or waiting-list control conditions. Found three treatment groups improved significantly on…

  18. Medición de coeficientes de extinción en CASLEO y características del CCD ROPER-2048B del telescopio JS

    Science.gov (United States)

    Fernández-Lajús, E.; Gamen, R.; Sánchez, M.; Scalia, M. C.; Baume, G. L.

    2016-08-01

    From observations made with the ``Jorge Sahade'' telescope of the Complejo Astronomico El Leoncito, the UBVRI-band extinction coeficients were measured, and some parameters and characteristics of the direct-image CCD camera ROPER 2048B were determined.

  19. Patterns of Multiple Risk Exposures for Low Receptive Vocabulary Growth 4-8 Years in the Longitudinal Study of Australian Children.

    Directory of Open Access Journals (Sweden)

    Daniel Christensen

    Full Text Available Risk exposures and predictions of child development outcomes typically estimate the independent effects of individual exposures. As a rule though, children are not exposed piecemeal to individual or single risks but, rather, they are exposed to clusters of risk. Many of these clusters of risks are better thought of as comprising a developmental "circumstance" with a substantial duration, over which period, additional risk exposures also accumulate. In this paper we examined the distribution of 16 single risk exposures for low language ability using latent class analysis across a sample of approximately 4000 children from the Longitudinal Study of Australian Children. The best fitting model identified six distinct classes. 46% of children were in a Developmentally Enabled group, 20% were in a group typified as Working Poor families, 10% of children were in group typified as Overwhelmed group, 9% of children were in a group defined by Child Developmental Delay, 8% of children were in a group defined by Low Human Capital, and 7% of children were in a group defined by Resource Poor non-English Speaking background families. These groups had quantitatively and qualitatively distinct patterns of risk factors and showed different onward trajectories of receptive vocabulary. Our results demonstrate a range of multiple risk profiles in a population-representative sample of Australian children and highlight the mix of risk factors faced by children. Children with distinct patterns of risk factors have different onward trajectories of receptive vocabulary development.

  20. Proton radiation damage assessment of a CCD for use in a Ultraviolet and Visible Spectrometer

    International Nuclear Information System (INIS)

    Gow, J.P.D.; Mason, J.; Leese, M.; Patel, M.; Hathi, B.

    2017-01-01

    This paper describes the radiation environment and radiation damage analysis performed for the Nadir and Occultation for MArs Discovery (NOMAD) Ultraviolet and Visible Spectrometer (UVIS) channel launched onboard the ExoMars Trace Gas Orbiter (TGO) in 2016. The aim of the instrument is to map the temporal and spatial variation of trace gases such as ozone and dust/cloud aerosols in the atmosphere of Mars. The instrument consists of a set of two miniature telescope viewing optics which allow for selective input onto the optical bench, where an e2v technologies CCD30-11 will be used as the detector. A Geometry Description Markup Language model of the spacecraft and instrument box was created and through the use of ESA's SPace ENVironment Information System (SPENVIS) an estimate of the 10 MeV equivalent proton fluence was made at a number of radiation sensitive regions within NOMAD, including that of the CCD30-11 which is the focus of this paper. The end of life 10 MeV equivalent proton fluence at the charge coupled device was estimated to be 4.7 × 10 9 protons.cm −2 ; three devices were irradiated at different levels up a 10 MeV equivalent fluence of 9.4 × 10 9 protons.cm −2 . The dark current, charge transfer inefficiency, charge storage, and cosmetic quality of the devices was investigated pre- and post-irradiation, determining that the devices will continue to provide excellent science throughout the mission.

  1. Adult exposure to ocean acidification is maladaptive for larvae of the Sydney rock oyster Saccostrea glomerata in the presence of multiple stressors.

    Science.gov (United States)

    Parker, Laura M; O'Connor, Wayne A; Byrne, Maria; Coleman, Ross A; Virtue, Patti; Dove, Michael; Gibbs, Mitchell; Spohr, Lorraine; Scanes, Elliot; Ross, Pauline M

    2017-02-01

    Parental effects passed from adults to their offspring have been identified as a source of rapid acclimation that may allow marine populations to persist as our surface oceans continue to decrease in pH. Little is known, however, whether parental effects are beneficial for offspring in the presence of multiple stressors. We exposed adults of the oyster Saccostrea glomerata to elevated CO 2 and examined the impacts of elevated CO 2 (control = 392; 856 µatm) combined with elevated temperature (control = 24; 28°C), reduced salinity (control = 35; 25) and reduced food concentration (control = full; half diet) on their larvae. Adult exposure to elevated CO 2 had a positive impact on larvae reared at elevated CO 2 as a sole stressor, which were 8% larger and developed faster at elevated CO 2 compared with larvae from adults exposed to ambient CO 2 These larvae, however, had significantly reduced survival in all multistressor treatments. This was particularly evident for larvae reared at elevated CO 2 combined with elevated temperature or reduced food concentration, with no larvae surviving in some treatment combinations. Larvae from CO 2 -exposed adults had a higher standard metabolic rate. Our results provide evidence that parental exposure to ocean acidification may be maladaptive when larvae experience multiple stressors. © 2017 The Author(s).

  2. Application of specialized RISC processor for realization of algorithms for track signal filtration on data read from CCD

    International Nuclear Information System (INIS)

    Ban, Ya.; Kotov, V.M.; Kharcharufkova, K.

    1987-01-01

    Algorithms for track signal filtration from bubble and streamer spark chambers read by CCD matrix with elements of 256x288 dimensions are described. The microprogrammed RISC processor is used for preliminary processing and filtration of data obtained. It makes possible to recognize and filter track elements in the zone of 0.25 mm 2 square during 0.17-0.20 s, that maintains it in real time operation

  3. Automatic Generation of Wide Dynamic Range Image without Pseudo-Edge Using Integration of Multi-Steps Exposure Images

    Science.gov (United States)

    Migiyama, Go; Sugimura, Atsuhiko; Osa, Atsushi; Miike, Hidetoshi

    Recently, digital cameras are offering technical advantages rapidly. However, the shot image is different from the sight image generated when that scenery is seen with the naked eye. There are blown-out highlights and crushed blacks in the image that photographed the scenery of wide dynamic range. The problems are hardly generated in the sight image. These are contributory cause of difference between the shot image and the sight image. Blown-out highlights and crushed blacks are caused by the difference of dynamic range between the image sensor installed in a digital camera such as CCD and CMOS and the human visual system. Dynamic range of the shot image is narrower than dynamic range of the sight image. In order to solve the problem, we propose an automatic method to decide an effective exposure range in superposition of edges. We integrate multi-step exposure images using the method. In addition, we try to erase pseudo-edges using the process to blend exposure values. Afterwards, we get a pseudo wide dynamic range image automatically.

  4. Viability evaluation of the reading system by CCD for application at the Fricke xylenol gel dosimetry developed by IPEN-Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Mangueira, Thyago Fressatti; Dias, Daniel Menezes; Campos, Leticia Lucente

    2009-01-01

    The use of chambers with coupled charge devices - CCD, is already used by research centres for the dose evaluation applying the Fricke xylenol gel dosemeter. This work evaluates the application of this optical reading technique for the FXG developed at the IPEN, Sao Paulo, Brazil

  5. A CCD photometric analysis of the old open cluster NGC 2420

    International Nuclear Information System (INIS)

    Anthony-Twarog, B.J.; Twarog, B.A.; Kaluzny, J.; Shara, M.M.

    1990-01-01

    Precision CCD photometry on the BV system of the core of the old open cluster NGC 2420 is analyzed to explore the value of such an approach for open clusters, particularly in the areas of Galactic and stellar evolution. The unevolved main sequence is shown to be narrow and well defined to the completeness limit of V = 18.5, and the distribution of stars away from the main sequence is shown to be bimodal, with a secondary peak located approximately 0.7 mag above the fiducial main sequence. It is estimated that 50 percent of the cluster systems are binary. Near the turnoff the cluster exhibits some detailed structure. Fiducial relations are given for the cluster extending from the lower main sequence to the red giant branch 1.5 mag above the clump. Comparisons are made between the NGC 2420 cluster and NGC 2506, the isochrones of VandenBerg (1985), and 47 Tuc, in order to estimate cluster parameters, including reddening and metallicity. 68 refs

  6. CCD[charge-coupled device]-based synchrotron x-ray detector for protein crystallography: Performance projected from an experiment

    International Nuclear Information System (INIS)

    Strauss, M.G.; Naday, I.; Sherman, I.S.; Kraimer, M.R.; Westbrook, E.M.

    1986-01-01

    The intense x radiation from a synchrotron source could, with a suitable detector, provide a complete set of diffraction images from a protein crystal before the crystal is damaged by radiation (2 to 3 min). An area detector consisting of a 40 mm dia. x-ray fluorescing phosphor, coupled with an image intensifier and lens to a CCD image sensor, was developed to determine the effectiveness of such a detector in protein crystallography. The detector was used in an experiment with a rotating anode x-ray generator. Diffraction patterns from a lysozyme crystal obtained with this detector are compared to those obtained with film. The two images appear to be virtually identical. The flux of 10 4 x-ray photons/s was observed on the detector at the rotating anode generator. At the 6-GeV synchrotron being designed at Argonne, the flux on an 80 x 80 mm 2 detector is expected to be >10 9 photons/s. The projected design of such a synchrotron detector shows that a diffraction-peak count >10 6 could be obtained in ∼0.5 s. With an additional ∼0.5 s readout time of a 512 x 512 pixel CCD, the data acquisition time per frame would be ∼1 s so that ninety 1 0 diffraction images could be obtained, with approximately 1% precision, in less than 3 min

  7. Front-illuminated versus back-illuminated photon-counting CCD-based gamma camera: important consequences for spatial resolution and energy resolution

    International Nuclear Information System (INIS)

    Heemskerk, Jan W T; Westra, Albert H; Linotte, Peter M; Ligtvoet, Kees M; Zbijewski, Wojciech; Beekman, Freek J

    2007-01-01

    Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high-resolution imaging with x-rays and gamma rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by a real-time image analysis of the scintillation light flashes ('photon-counting mode'). The electron-multiplying CCD (EMCCD) is well suited for fast read out, since even at high frame rates it has extremely low read-out noise. Back-illuminated (BI) EMCCDs have much higher quantum efficiency than front-illuminated (FI) EMCCDs. Here we compare the spatial and energy resolution of gamma cameras based on FI and BI EMCCDs. The CCDs are coupled to a 1000 μm thick columnar CsI(Tl) crystal for the purpose of Tc-99m and I-125 imaging. Intrinsic spatial resolutions of 44 μm for I-125 and 49 μm for Tc-99m were obtained when using a BI EMCCD, which is an improvement by a factor of about 1.2-2 over the FI EMCCD. Furthermore, in the energy spectrum of the BI EMCCD, the I-125 signal could be clearly separated from the background noise, which was not the case for the FI EMCCD. The energy resolution of a BI EMCCD for Tc-99m was estimated to be approximately 36 keV, full width at half maximum, at 141 keV. The excellent results for the BI EMCCD encouraged us to investigate the cooling requirements for our setup. We have found that for the BI EMCCD, the spatial and energy resolution, as well as image noise, remained stable over a range of temperatures from -50 deg. C to -15 deg. C. This is a significant advantage over the FI EMCCD, which suffered from loss of spatial and especially energy resolution at temperatures as low as -40 deg. C. We conclude that the use of BI EMCCDs may significantly improve the imaging capabilities and the cost efficiency of CCD-based high-resolution gamma cameras. (note)

  8. An approach for assessing human exposures to chemical mixtures in the environment

    International Nuclear Information System (INIS)

    Rice, Glenn; MacDonell, Margaret; Hertzberg, Richard C.; Teuschler, Linda; Picel, Kurt; Butler, Jim; Chang, Young-Soo; Hartmann, Heidi

    2008-01-01

    Humans are exposed daily to multiple chemicals, including incidental exposures to complex chemical mixtures released into the environment and to combinations of chemicals that already co-exist in the environment because of previous releases from various sources. Exposures to chemical mixtures can occur through multiple pathways and across multiple routes. In this paper, we propose an iterative approach for assessing exposures to environmental chemical mixtures; it is similar to single-chemical approaches. Our approach encompasses two elements of the Risk Assessment Paradigm: Problem Formulation and Exposure Assessment. Multiple phases of the assessment occur in each element of the paradigm. During Problem Formulation, analysts identify and characterize the source(s) of the chemical mixture, ensure that dose-response and exposure assessment measures are concordant, and develop a preliminary evaluation of the mixture's fate. During Exposure Assessment, analysts evaluate the fate of the chemicals comprising the mixture using appropriate models and measurement data, characterize the exposure scenario, and estimate human exposure to the mixture. We also describe the utility of grouping the chemicals to be analyzed based on both physical-chemical properties and an understanding of environmental fate. In the article, we also highlight the need for understanding of changes in the mixture composition in the environment due to differential transport, differential degradation, and differential partitioning to other media. The section describes the application of the method to various chemical mixtures, highlighting issues associated with assessing exposures to chemical mixtures in the environment

  9. Sampling strategy for estimating human exposure pathways to consumer chemicals

    NARCIS (Netherlands)

    Papadopoulou, Eleni; Padilla-Sanchez, Juan A.; Collins, Chris D.; Cousins, Ian T.; Covaci, Adrian; de Wit, Cynthia A.; Leonards, Pim E.G.; Voorspoels, Stefan; Thomsen, Cathrine; Harrad, Stuart; Haug, Line S.

    2016-01-01

    Human exposure to consumer chemicals has become a worldwide concern. In this work, a comprehensive sampling strategy is presented, to our knowledge being the first to study all relevant exposure pathways in a single cohort using multiple methods for assessment of exposure from each exposure pathway.

  10. An exposure indicator for digital radiography: AAPM Task Group 116 (executive summary).

    Science.gov (United States)

    Shepard, S Jeff; Wang, Jihong; Flynn, Michael; Gingold, Eric; Goldman, Lee; Krugh, Kerry; Leong, David L; Mah, Eugene; Ogden, Kent; Peck, Donald; Samei, Ehsan; Wang, Jihong; Willis, Charles E

    2009-07-01

    Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film-based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines.

  11. Damage threshold from large retinal spot size repetitive-pulse laser exposures.

    Science.gov (United States)

    Lund, Brian J; Lund, David J; Edsall, Peter R

    2014-10-01

    The retinal damage thresholds for large spot size, multiple-pulse exposures to a Q-switched, frequency doubled Nd:YAG laser (532 nm wavelength, 7 ns pulses) have been measured for 100 μm and 500 μm retinal irradiance diameters. The ED50, expressed as energy per pulse, varies only weakly with the number of pulses, n, for these extended spot sizes. The previously reported threshold for a multiple-pulse exposure for a 900 μm retinal spot size also shows the same weak dependence on the number of pulses. The multiple-pulse ED50 for an extended spot-size exposure does not follow the n dependence exhibited by small spot size exposures produced by a collimated beam. Curves derived by using probability-summation models provide a better fit to the data.

  12. Perinatal multiple exposure to neurotoxic (lead, methylmercury, ethylmercury, and aluminum) substances and neurodevelopment at six and 24 months of age

    International Nuclear Information System (INIS)

    Marques, Rejane C.; Bernardi, José V.E.; Dórea, José G.; Moreira de Fatima R, Maria; Malm, Olaf

    2014-01-01

    We studied neurodevelopment in infants from two communities. Children living in the vicinity of tin-ore kilns and smelters – TOKS; n = 51) were compared to children from a fishing village (Itapuã; n = 45). Mean hair-Hg (HHg) concentrations were significantly higher in Itapuã children which received significantly (p = 0.0000001) less mean ethylmercury (88.6 μg) from Thimerosal-containing vaccines (TCV) than the TOKS children (120 μg). Breast-milk Pb concentrations were significantly higher in the TOKS mothers (p = 0.000017; 10.04 vs. 3.9 μg L −1 ). Bayley mental development index (MDI) and psychomotor development index (PDI) were statistically significant (respectively p < 0.0000001, p = 0.000007) lower for the TOKS children only at 24 months of age. Multivariate regression analysis showed that MDI was negatively affected by breast-milk Pb and by HHg. PDI was positively affected by breastfeeding and negatively affected by ethylmercury. Milestone achievements were negatively affected by breast-milk Pb (age of walking) and by HHg (age of talking). - Highlights: • Maternal MeHg and Pb, and iatrogenic EtHg (plus Al) exposures are real life scenarios. • Multiple exposures in early life are a dominant cause of neurodevelopmental delays. • Aggravation and/or reversibility of outcomes followed identifiable exposure patterns. - Distinct patterns of metal exposures showed significant differences in neurodevelopmental outcomes. Pb and EtHg showed a dominant cause of neurodevelopmental delays

  13. Image Alignment for Multiple Camera High Dynamic Range Microscopy

    OpenAIRE

    Eastwood, Brian S.; Childs, Elisabeth C.

    2012-01-01

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability fo...

  14. On-ground and in-orbit characterisation plan for the PLATO CCD normal cameras

    Science.gov (United States)

    Gow, J. P. D.; Walton, D.; Smith, A.; Hailey, M.; Curry, P.; Kennedy, T.

    2017-11-01

    PLAnetary Transits and Ocillations (PLATO) is the third European Space Agency (ESA) medium class mission in ESA's cosmic vision programme due for launch in 2026. PLATO will carry out high precision un-interrupted photometric monitoring in the visible band of large samples of bright solar-type stars. The primary mission goal is to detect and characterise terrestrial exoplanets and their systems with emphasis on planets orbiting in the habitable zone, this will be achieved using light curves to detect planetary transits. PLATO uses a novel multi- instrument concept consisting of 26 small wide field cameras The 26 cameras are made up of a telescope optical unit, four Teledyne e2v CCD270s mounted on a focal plane array and connected to a set of Front End Electronics (FEE) which provide CCD control and readout. There are 2 fast cameras with high read-out cadence (2.5 s) for magnitude ~ 4-8 stars, being developed by the German Aerospace Centre and 24 normal (N) cameras with a cadence of 25 s to monitor stars with a magnitude greater than 8. The N-FEEs are being developed at University College London's Mullard Space Science Laboratory (MSSL) and will be characterised along with the associated CCDs. The CCDs and N-FEEs will undergo rigorous on-ground characterisation and the performance of the CCDs will continue to be monitored in-orbit. This paper discusses the initial development of the experimental arrangement, test procedures and current status of the N-FEE. The parameters explored will include gain, quantum efficiency, pixel response non-uniformity, dark current and Charge Transfer Inefficiency (CTI). The current in-orbit characterisation plan is also discussed which will enable the performance of the CCDs and their associated N-FEE to be monitored during the mission, this will include measurements of CTI giving an indication of the impact of radiation damage in the CCDs.

  15. The simulated spectrum of the OGRE X-ray EM-CCD camera system

    Science.gov (United States)

    Lewis, M.; Soman, M.; Holland, A.; Lumb, D.; Tutt, J.; McEntaffer, R.; Schultz, T.; Holland, K.

    2017-12-01

    The X-ray astronomical telescopes in use today, such as Chandra and XMM-Newton, use X-ray grating spectrometers to probe the high energy physics of the Universe. These instruments typically use reflective optics for focussing onto gratings that disperse incident X-rays across a detector, often a Charge-Coupled Device (CCD). The X-ray energy is determined from the position that it was detected on the CCD. Improved technology for the next generation of X-ray grating spectrometers has been developed and will be tested on a sounding rocket experiment known as the Off-plane Grating Rocket Experiment (OGRE). OGRE aims to capture the highest resolution soft X-ray spectrum of Capella, a well-known astronomical X-ray source, during an observation period lasting between 3 and 6 minutes whilst proving the performance and suitability of three key components. These three components consist of a telescope made from silicon mirrors, gold coated silicon X-ray diffraction gratings and a camera that comprises of four Electron-Multiplying (EM)-CCDs that will be arranged to observe the soft X-rays dispersed by the gratings. EM-CCDs have an architecture similar to standard CCDs, with the addition of an EM gain register where the electron signal is amplified so that the effective signal-to-noise ratio of the imager is improved. The devices also have incredibly favourable Quantum Efficiency values for detecting soft X-ray photons. On OGRE, this improved detector performance allows for easier identification of low energy X-rays and fast readouts due to the amplified signal charge making readout noise almost negligible. A simulation that applies the OGRE instrument performance to the Capella soft X-ray spectrum has been developed that allows the distribution of X-rays onto the EM-CCDs to be predicted. A proposed optical model is also discussed which would enable the missions minimum success criteria's photon count requirement to have a high chance of being met with the shortest possible

  16. A new and efficient transient noise analysis technique for simulation of CCD image sensors or particle detectors

    International Nuclear Information System (INIS)

    Bolcato, P.; Jarron, P.; Poujois, R.

    1993-01-01

    CCD image sensors or switched capacitor circuits used for particle detectors have a certain noise level affecting the resolution of the detector. A new noise simulation technique for these devices is presented that has been implemented in the circuit simulator ELDO. The approach is particularly useful for noise simulation in analog sampling circuits. Comparison between simulations and experimental results has been made and is shown for a 1.5 μ CMOS current mode amplifier designed for high-rate particle detectors. (R.P.) 5 refs., 7 figs

  17. Ultra-sensitive, stable isotope assisted quantification of multiple urinary mycotoxin exposure biomarkers.

    Science.gov (United States)

    Šarkanj, Bojan; Ezekiel, Chibundu N; Turner, Paul C; Abia, Wilfred A; Rychlik, Michael; Krska, Rudolf; Sulyok, Michael; Warth, Benedikt

    2018-08-17

    There is a critical need to better understand the patterns, levels and combinatory effects of exposures we are facing through our diet and environment. Mycotoxin mixtures are of particular concern due to chronic low dose exposures caused by naturally contaminated food. To facilitate new insights into their role in chronic disease, mycotoxins and their metabolites are quantified in bio-fluids as biomarkers of exposure. Here, we describe a highly sensitive urinary assay based on ultra-high performance liquid chromatography - tandem mass spectrometer (UHPLC-MS/MS) and 13 C-labelled or deuterated internal standards covering the most relevant regulated and emerging mycotoxins. Utilizing enzymatic pre-treatment, solid phase extraction and UHPLC separation, the sensitivity of the method was significantly higher (10-160x lower LODs) than in a previously described method used for comparison purpose, and stable isotopes provided compensation for challenging matrix effects. This method was in-house validated and applied to re-assess mycotoxin exposure in urine samples obtained from Nigerian children, adolescent and adults, naturally exposed through their regular diet. Owing to the methods high sensitivity, biomarkers were detected in all samples. The mycoestrogen zearalenone was the most frequently detected contaminant (82%) but also ochratoxin A (76%), aflatoxin M 1 (73%) and fumonisin B 1 (71%) were quantified in a large share of urines. Overall, 57% of 120 urines were contaminated with both, aflatoxin M 1 and fumonisin B 1 , and other co-exposures were frequent. These results clearly demonstrate the advanced performance of the method to assess lowest background exposures (pg mL -1 range) using a single, highly robust assay that will allow for the systematic investigation of low dose effects on human health. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Photometric correction for an optical CCD-based system based on the sparsity of an eight-neighborhood gray gradient.

    Science.gov (United States)

    Zhang, Yuzhong; Zhang, Yan

    2016-07-01

    In an optical measurement and analysis system based on a CCD, due to the existence of optical vignetting and natural vignetting, photometric distortion, in which the intensity falls off away from the image center, affects the subsequent processing and measuring precision severely. To deal with this problem, an easy and straightforward method used for photometric distortion correction is presented in this paper. This method introduces a simple polynomial fitting model of the photometric distortion function and employs a particle swarm optimization algorithm to get these model parameters by means of a minimizing eight-neighborhood gray gradient. Compared with conventional calibration methods, this method can obtain the profile information of photometric distortion from only a single common image captured by the optical CCD-based system, with no need for a uniform luminance area source used as a standard reference source and relevant optical and geometric parameters in advance. To illustrate the applicability of this method, numerical simulations and photometric distortions with different lens parameters are evaluated using this method in this paper. Moreover, the application example of temperature field correction for casting billets also demonstrates the effectiveness of this method. The experimental results show that the proposed method is able to achieve the maximum absolute error for vignetting estimation of 0.0765 and the relative error for vignetting estimation from different background images of 3.86%.

  19. Increased Transmissibility of Leishmania donovani From the Mammalian Host to Vector Sand Flies After Multiple Exposures to Sand Fly Bites.

    Science.gov (United States)

    Valverde, Joanna G; Paun, Andrea; Inbar, Ehud; Romano, Audrey; Lewis, Michael; Ghosh, Kashinath; Sacks, David

    2017-04-15

    Patients with active visceral leishmaniasis are important reservoirs in the anthroponotic transmission cycle of Leishmania donovani. The role of the blood or skin as a source of infection to sand flies remains unclear, and the possible effect of multiple exposures to fly bites on transmissibility has not been addressed. L. donovani-infected hamsters underwent xenodiagnoses with Lutzomyia longipalpis on the same or different sites on the abdomen on 2 consecutive days or by artificial feeding on the skin or blood. The transmission of L. donovani from sick hamsters to flies was surprisingly low (mean, 24% of fed flies). New flies fed on the same site acquired significantly more infections (mean, 61%; P Leishmania donovani. Using the hamster model of visceral disease, we demonstrate that prior exposure to bites of uninfected sand flies potentiates their ability to transmit infection to the vector. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. Agent Orange exposure and prevalence of self-reported diseases in Korean Vietnam veterans.

    Science.gov (United States)

    Yi, Sang-Wook; Ohrr, Heechoul; Hong, Jae-Seok; Yi, Jee-Jeon

    2013-09-01

    The aim of this study was to evaluate the association between Agent Orange exposure and self-reported diseases in Korean Vietnam veterans. A postal survey of 114 562 Vietnam veterans was conducted. The perceived exposure to Agent Orange was assessed by a 6-item questionnaire. Two proximity-based Agent Orange exposure indices were constructed using division/brigade-level and battalion/company-level unit information. Adjusted odds ratios (ORs) for age and other confounders were calculated using a logistic regression model. The prevalence of all self-reported diseases showed monotonically increasing trends as the levels of perceived self-reported exposure increased. The ORs for colon cancer (OR, 1.13), leukemia (OR, 1.56), hypertension (OR, 1.03), peripheral vasculopathy (OR, 1.07), enterocolitis (OR, 1.07), peripheral neuropathy (OR, 1.07), multiple nerve palsy (OR, 1.14), multiple sclerosis (OR, 1.24), skin diseases (OR, 1.05), psychotic diseases (OR, 1.07) and lipidemia (OR, 1.05) were significantly elevated for the high exposure group in the division/brigade-level proximity-based exposure analysis, compared to the low exposure group. The ORs for cerebral infarction (OR, 1.08), chronic bronchitis (OR, 1.05), multiple nerve palsy (OR, 1.07), multiple sclerosis (OR, 1.16), skin diseases (OR, 1.05), and lipidemia (OR, 1.05) were significantly elevated for the high exposure group in the battalion/company-level analysis. Korean Vietnam veterans with high exposure to Agent Orange experienced a higher prevalence of several self-reported chronic diseases compared to those with low exposure by proximity-based exposure assessment. The strong positive associations between perceived self-reported exposure and all self-reported diseases should be evaluated with discretion because the likelihood of reporting diseases was directly related to the perceived intensity of Agent Orange exposure.

  1. Experimental comparison of the high-speed imaging performance of an EM-CCD and sCMOS camera in a dynamic live-cell imaging test case.

    Directory of Open Access Journals (Sweden)

    Hope T Beier

    Full Text Available The study of living cells may require advanced imaging techniques to track weak and rapidly changing signals. Fundamental to this need is the recent advancement in camera technology. Two camera types, specifically sCMOS and EM-CCD, promise both high signal-to-noise and high speed (>100 fps, leaving researchers with a critical decision when determining the best technology for their application. In this article, we compare two cameras using a live-cell imaging test case in which small changes in cellular fluorescence must be rapidly detected with high spatial resolution. The EM-CCD maintained an advantage of being able to acquire discernible images with a lower number of photons due to its EM-enhancement. However, if high-resolution images at speeds approaching or exceeding 1000 fps are desired, the flexibility of the full-frame imaging capabilities of sCMOS is superior.

  2. Environmental issues and work: women with multiple chemical sensitivities.

    Science.gov (United States)

    Lipson, Juliene G; Doiron, Nathalie

    2006-08-01

    Multiple chemical sensitivities (MCS) is an acquired condition in which exposure to low levels of chemicals causes symptoms in multiple organ systems. Some 12%-16% of the U.S. population has some level of chemical sensitivity, 80% of whom are women. Attempts to reduce chemical exposures leads to enormous life difficulties at home, school, and workplace. We base our article on an ethnographic study of MCS in the United States and Canada. We describe here themes related to work issues in terms of a general trajectory of becoming sick from work exposures, coping with toxic physical environments and dealing with coworkers and, when unable to continue working, applying for workers' compensation, or disability status, or both.

  3. CCD imagery of the S0 galaxies NGC 3990 and NGC 3998

    International Nuclear Information System (INIS)

    Welch, G.A.; Welch, D.M.K.; Dupuy, D.L.

    1991-01-01

    The structure and colors of NGC 3990 and NGC 3998 are investigated using BR CCD imagery. Fits of bulge-disk models of the galaxies indicate that both disks are somewhat brighter and more compact than typical S0 galaxies in the Virgo and Fornax clusters. Although the two galaxies are separated by only about 3.5 arcmin, none of the obvious signs of gravitational interaction are seen. The colors of both galaxies are normal; the disk of NGC 3998 is somewhat bluer than its bulge. The search has failed to reveal the interstellar dust predicted from the neutral hydrogen observations of NGC 3998. The dust that is seen appears to be mixed with ionized gas which occupies the center of this galaxy and may be the same material seen at longer wavelengths by the IRAS experiment. Its low abundance relative to the neutral gas is consistent with the idea that the ISM was contributed by a gas-rich dwarf galaxy in a destructive merger. 31 refs

  4. Formal recycling of e-waste leads to increased exposure to toxic metals: an occupational exposure study from Sweden.

    Science.gov (United States)

    Julander, Anneli; Lundgren, Lennart; Skare, Lizbet; Grandér, Margaretha; Palm, Brita; Vahter, Marie; Lidén, Carola

    2014-12-01

    Electrical and electronic waste (e-waste) contains multiple toxic metals. However, there is currently a lack of exposure data for metals on workers in formal recycling plants. The objective of this study was to evaluate workers' exposure to metals, using biomarkers of exposure in combination with monitoring of personal air exposure. We assessed exposure to 20 potentially toxic metals among 55 recycling workers and 10 office workers at three formal e-waste recycling plants in Sweden. Workers at two of the plants were followed-up after 6 months. We collected the inhalable fraction and OFC (37-mm) fraction of particles, using personal samplers, as well as spot samples of blood and urine. We measured metal concentrations in whole blood, plasma, urine, and air filters using inductively coupled plasma-mass spectrometry following acid digestion. The air sampling indicated greater airborne exposure, 10 to 30 times higher, to most metals among the recycling workers handling e-waste than among the office workers. The exposure biomarkers showed significantly higher concentrations of chromium, cobalt, indium, lead, and mercury in blood, urine, and/or plasma of the recycling workers, compared with the office workers. Concentrations of antimony, indium, lead, mercury, and vanadium showed close to linear associations between the inhalable particle fraction and blood, plasma, or urine. In conclusion, our study of formal e-waste recycling shows that workers performing recycling tasks are exposed to multiple toxic metals. Copyright © 2014. Published by Elsevier Ltd.

  5. Experience of in-cell visual inspection using CCD camera in hot cell of Reprocessing Plant

    International Nuclear Information System (INIS)

    Reddy, Padi Srinivas; Amudhu Ramesh Kumar, R.; Geo Mathews, M.; Ravisankar, A.

    2013-01-01

    This paper describes the selection, customization and operating experience of the visual inspection system for the hot cell of a Reprocessing Plant. For process equipment such as fuel chopping machine, dissolver, centrifuge, centrifugal extractors etc., viewing of operations and maintenance using manipulators is required. For this, the service of in-cell camera is essential. The ambience of the hot cell of Compact facility for Reprocessing of Advanced fuels in Lead cell (CORAL) for the reprocessing of fast reactor spent fuel has high gamma radiation and acidic vapors. Black and white Charge Coupled Device (CCD) camera has been used in CORAL incorporating in-house modifications to suit the operating ambient conditions, thereby extending the operating life of the camera. (author)

  6. Violence Exposure and Victimization among Rural Adolescents

    Science.gov (United States)

    Mykota, David B.; Laye, Adele

    2015-01-01

    Violence exposure is a serious public health concern for adolescents in schools today. Violence exposure can be quite severe and frequent with multiple acts of indirect and direct victimization having lasting effects on the physical, emotional, and intellectual well-being of adolescents. The purpose of the present study is to examine the rates of…

  7. Dynamic imaging with a triggered and intensified CCD camera system in a high-intensity neutron beam

    International Nuclear Information System (INIS)

    Vontobel, P.; Frei, G.; Brunner, J.; Gildemeister, A.E.; Engelhardt, M.

    2005-01-01

    When time-dependent processes within metallic structures should be inspected and visualized, neutrons are well suited due to their high penetration through Al, Ag, Ti or even steel. Then it becomes possible to inspect the propagation, distribution and evaporation of organic liquids as lubricants, fuel or water. The principle set-up of a suited real-time system was implemented and tested at the radiography facility NEUTRA of PSI. The highest beam intensity there is 2x10 7 cm -2 s -1 , which enables to observe sequences in a reasonable time and quality. The heart of the detection system is the MCP intensified CCD camera PI-Max with a Peltier cooled chip (1300x1340 pixels). The intensifier was used for both gating and image enhancement, where as the information was accumulated over many single frames on the chip before readout. Although, a 16-bit dynamic range is advertised by the camera manufacturers, it must be less due to the inherent noise level from the intensifier. The obtained result should be seen as the starting point to go ahead to fit the different requirements of car producers in respect to fuel injection, lubricant distribution, mechanical stability and operation control. Similar inspections will be possible for all devices with repetitive operation principle. Here, we report about two measurements dealing with the lubricant distribution in a running motorcycle motor turning at 1200rpm. We were monitoring the periodic stationary movements of piston, valves and camshaft with a micro-channel plate intensified CCD camera system (PI-Max 1300RB, Princeton Instruments) triggered at exactly chosen time points

  8. Mortality from non-malignant respiratory diseases among people with silicosis in Hong Kong: exposure-response analyses for exposure to silica dust.

    Science.gov (United States)

    Tse, L A; Yu, I T S; Leung, C C; Tam, W; Wong, T W

    2007-02-01

    To examine the exposure-response relationships between various indices of exposure to silica dust and the mortality from non-malignant respiratory diseases (NMRDs) or chronic obstructive pulmonary diseases (COPDs) among a cohort of workers with silicosis in Hong Kong. The concentrations of respirable silica dust were assigned to each industry and job task according to historical industrial hygiene measurements documented previously in Hong Kong. Exposure indices included cumulative dust exposure (CDE) and mean dust concentration (MDC). Penalised smoothing spline models were used as a preliminary step to detect outliers and guide further analyses. Multiple Cox's proportional hazard models were used to estimate the dust effects on the risk of mortality from NMRDs or COPDs after truncating the highest exposures. 371 of the 853 (43.49%) deaths occurring among 2789 workers with silicosis during 1981-99 were from NMRDs, and 101 (27.22%) NMRDs were COPDs. Multiple Cox's proportional hazard models showed that CDE (p = 0.009) and MDC (pcaisson workers and among those ever employed in other occupations with high exposure to silica dust. No exposure-response relationship was observed for surface construction workers with low exposures. A clear upward trend for both NMRDs and COPDs mortality was found with increasing severity of radiological silicosis. This study documented an exposure-response relationship between exposure to silica dust and the risk of death from NMRDs or COPDs among workers with silicosis, except for surface construction workers with low exposures. The risk of mortality from NMRDs increased significantly with the progression of International Labor Organization categories, independent of dust effects.

  9. Tests of a new CCD-camera based neutron radiography detector system at the reactor stations in Munich and Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E; Pleinert, H [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schillinger, B [Technische Univ. Muenchen (Germany); Koerner, S [Atominstitut der Oesterreichischen Universitaeten, Vienna (Austria)

    1997-09-01

    The performance of the new neutron radiography detector designed at PSI with a cooled high sensitive CCD-camera was investigated under real neutronic conditions at three beam ports of two reactor stations. Different converter screens were applied for which the sensitivity and the modulation transfer function (MTF) could be obtained. The results are very encouraging concerning the utilization of this detector system as standard tool at the radiography stations at the spallation source SINQ. (author) 3 figs., 5 refs.

  10. Characterizing Risks of Exposures to Combined Stressors: An Overview

    Science.gov (United States)

    Cumulative risk assessment (CRA) addresses the impacts of multiple chemical and nonchemical stressors on communities, resulting from complex exposures for populations with a variety of vulnerabilities. These efforts focus on real world exposure scenarios and applications that ra...

  11. Enhanced optical power of GaN-based light-emitting diode with compound photonic crystals by multiple-exposure nanosphere-lens lithography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yonghui; Wei, Tongbo, E-mail: tbwei@semi.ac.cn; Xiong, Zhuo; Shang, Liang; Tian, Yingdong; Zhao, Yun; Zhou, Pengyu; Wang, Junxi; Li, Jinmin [Semiconductor Lighting Technology Research and Development Center, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China)

    2014-07-07

    The light-emitting diodes (LEDs) with single, twin, triple, and quadruple photonic crystals (PCs) on p-GaN are fabricated by multiple-exposure nanosphere-lens lithography (MENLL) process utilizing the focusing behavior of polystyrene spheres. Such a technique is easy and economical for use in fabricating compound nano-patterns. The optimized tilted angle is decided to be 26.6° through mathematic calculation to try to avoid the overlay of patterns. The results of scanning electron microscopy and simulations reveal that the pattern produced by MENLL is a combination of multiple ovals. Compared to planar-LED, the light output power of LEDs with single, twin, triple, and quadruple PCs is increased by 14.78%, 36.03%, 53.68%, and 44.85% under a drive current 350 mA, respectively. Furthermore, all PC-structures result in no degradation of the electrical properties. The stimulated results indicate that the highest light extraction efficiency of LED with the clover-shape triple PC is due to the largest scattering effect on propagation of light from GaN into air.

  12. Relationship between exposure to multiple noise sources and noise annoyance

    NARCIS (Netherlands)

    Miedema, H.M.E.

    2004-01-01

    Relationships between exposure to noise [metric: day-night level (DNL) or day-evening-night level (DENL)] from a single source (aircraft, road traffic, or railways) and annoyance based on a large international dataset have been published earlier. Also for stationary sources relationships have been

  13. A physiologically based pharmacokinetic (PB/PK) model for multiple exposure routes for soman in multiple species

    NARCIS (Netherlands)

    Sweeney, R.E.; Langenberg, J.P.; Maxwell, D.M.

    2006-01-01

    A physiologically based pharmacokinetic (PB/PK) model has been developed in advanced computer simulation language (ACSL) to describe blood and tissue concentration-time profiles of the C(±)P(-) stereoisomers of soman after inhalation, subcutaneous and intravenous exposures at low (0.8-1.0 × LD50),

  14. Hubble Space Telescope STIS observations of GRB 000301C: CCD imaging and near-ultraviolet MAMA spectroscopy

    DEFF Research Database (Denmark)

    Smette, A.; Fruchter, A.S.; Gull, T.R.

    2001-01-01

    We present Space Telescope Imaging Spectrograph observations of the optical transient (OT) counterpart of the c-ray burster GRB 000301C obtained 5 days after the burst, on 2000 March 6. CCD clear-aperture imaging reveals a R similar or equal to 21.50 +/- 0.15 source with no apparent host galaxy...... Telescope images appear to lie on the stellar field of a host galaxy, and as the large H I column density measured here and in later ground-based observations is unlikely on a random line of sight, we believe we are probably seeing absorption from H I in the host galaxy. In any case, this represents...

  15. Radiation exposure modeling and project schedule visualization

    International Nuclear Information System (INIS)

    Jaquish, W.R.; Enderlin, V.R.

    1995-10-01

    This paper discusses two applications using IGRIP (Interactive Graphical Robot Instruction Program) to assist environmental remediation efforts at the Department of Energy (DOE) Hanford Site. In the first application, IGRIP is used to calculate the estimated radiation exposure to workers conducting tasks in radiation environments. In the second, IGRIP is used as a configuration management tool to detect interferences between equipment and personnel work areas for multiple projects occurring simultaneously in one area. Both of these applications have the capability to reduce environmental remediation costs by reducing personnel radiation exposure and by providing a method to effectively manage multiple projects in a single facility

  16. Orthodontic exposure of multiple lmpactions: a case report.

    Science.gov (United States)

    Munda-Lacson, Maridin C; Venugopal, Adith

    2014-01-01

    There are rare cases of impacted permanent central incisors with dilacerations, a dental deformity characterized by pronounced angulations of the longitudinal tooth axis. Impaction of maxillary canines is an orthodontic anomaly that causes facial and dentoalveolar system problems, both functional and esthetic. A combination of surgery and orthodontics is important in bringing impacted teeth to their ideal position in the dental arch. This is a case report of a 10-year-old patient with impacted and dilacerated right central incisor and impacted left maxillary canine, following surgical exposure and appropriate orthodontic traction, the impacted teeth were surgically exposed and aligned into the dental arch.

  17. school survey of exposure to violence and posttraumatic stress ...

    African Journals Online (AJOL)

    Epidemiological data specifically documenting PTSD prevalence following violence exposure in children and adolescents in South Africa is lacking. In this preliminary survey, a positive association was found between exposure to violent and multiple traumas and posttraumatic stress disorder symptoms in adolescents.

  18. Multiple rotation assessment through isothetic fringes in speckle photography

    International Nuclear Information System (INIS)

    Angel, Luciano; Tebaldi, Myrian; Bolognini, Nestor

    2007-01-01

    The use of different pupils for storing each speckled image in speckle photography is employed to determine multiple in-plane rotations. The method consists of recording a four-exposure specklegram where the rotations are done between exposures. This specklegram is then optically processed in a whole field approach rendering isothetic fringes, which give detailed information about the multiple rotations. It is experimentally demonstrated that the proposed arrangement permits the depiction of six isothetics in order to measure either six different angles or three nonparallel components for two local general in-plane displacements

  19. Large-scale neurochemical metabolomics analysis identifies multiple compounds associated with methamphetamine exposure.

    Science.gov (United States)

    McClay, Joseph L; Adkins, Daniel E; Vunck, Sarah A; Batman, Angela M; Vann, Robert E; Clark, Shaunna L; Beardsley, Patrick M; van den Oord, Edwin J C G

    2013-04-01

    Methamphetamine (MA) is an illegal stimulant drug of abuse with serious negative health consequences. The neurochemical effects of MA have been partially characterized, with a traditional focus on classical neurotransmitter systems. However, these directions have not yet led to novel drug treatments for MA abuse or toxicity. As an alternative approach, we describe here the first application of metabolomics to investigate the neurochemical consequences of MA exposure in the rodent brain. We examined single exposures at 3 mg/kg and repeated exposures at 3 mg/kg over 5 days in eight common inbred mouse strains. Brain tissue samples were assayed using high-throughput gas and liquid chromatography mass spectrometry, yielding quantitative data on >300 unique metabolites. Association testing and false discovery rate control yielded several metabolome-wide significant associations with acute MA exposure, including compounds such as lactate ( p = 4.4 × 10 -5 , q = 0.013), tryptophan ( p = 7.0 × 10 -4 , q = 0.035) and 2-hydroxyglutarate ( p = 1.1 × 10 -4 , q = 0.022). Secondary analyses of MA-induced increase in locomotor activity showed associations with energy metabolites such as succinate ( p = 3.8 × 10 -7 ). Associations specific to repeated (5 day) MA exposure included phosphocholine ( p = 4.0 × 10 -4 , q = 0.087) and ergothioneine ( p = 3.0 × 10 -4 , q = 0.087). Our data appear to confirm and extend existing models of MA action in the brain, whereby an initial increase in energy metabolism, coupled with an increase in behavioral locomotion, gives way to disruption of mitochondria and phospholipid pathways and increased endogenous antioxidant response. Our study demonstrates the power of comprehensive MS-based metabolomics to identify drug-induced changes to brain metabolism and to develop neurochemical models of drug effects.

  20. Cámara CCD Directa con el Telescopio de 2.15 m del CASLEO: algunos diagnósticos

    Science.gov (United States)

    Cellone, S. A.

    Se efectuaron algunas pruebas con la cámara CCD (+ Reductor Focal) instalada en el foco Cassegrain del Telescopio de 2.15 m del Complejo Astronómico El Leoncito (CASLEO). Las conclusiones más significativas son: Los tiempos de exposición efectivos difieren de los nominales en una fracción apreciable de segundo. En exposiciones de menos de 3 segundos, la iluminación no es pareja en todo el detector. En consecuencia, se recomiendan los pasos a seguir por los astrónomos tanto durante la observación como en la reducción de sus datos.

  1. A compact CCD-monitored atomic force microscope with optical vision and improved performances.

    Science.gov (United States)

    Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang

    2013-09-01

    A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.

  2. Precise CCD positions of Triton in 2014-2016 from the Gaia DR1

    Science.gov (United States)

    Wang, N.; Peng, Q. Y.; Peng, H. W.; Zhang, Q. F.

    2018-04-01

    755 CCD observations during the years 2014-2016 have been reduced to derive the precise positions of Triton, the first satellite of Neptune. The observations were made by the 1 m telescope at Yunnan Observatory over 15 nights during the years 2014-2016. The theoretical position of Triton was retrieved from the Jet Propulsion Laboratory Horizons system. Our results show that when the newest Gaia catalogue (Gaia DR1) is referred to the mean O-Cs (observed minus computed) residuals are about 0.042 and -0.006 arcsec, the dispersions are 0.012 and 0.012 arcsec in right ascension and declination, respectively. The dispersions are improved very significantly when the Gaia DR1 is referred to. However, the agreement in right ascension is not so good as that in declination, the reason might come from the uncertainty of planet ephemeris. More observations are needed to confirm this.

  3. Noise characterization of weighting schemes for combination of multiple exposures

    DEFF Research Database (Denmark)

    Kirk, Kristian; Andersen, Hans Jørgen

    2006-01-01

    A method for capturing high intensity dynamic range scenes with a low dynamic range camera consists in taking a series of images with different exposure settings and combining these into a single high dynamic range image. The combined image values are found by weighted averaging of values from...

  4. Studies of dwarf irregular galaxies. 1. B and V CCD photometry of the brighter stars in Sextans A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, A.R.

    1987-02-15

    B and V CCD photometry of Sextans A to limits V=22, B=23.5 demonstrate that two recent studies of the galaxy contain considerable systematic errors in their B and V photometry. These errors are determined here so that corrections can be made to this photometry. The mean absolute magnitudes of the three brightest red and blue stars are found to be =-7.6 and -7.4, =-5.8 and -7.4, respectively. The Cephied distance modulus of Sextans A is revised to 26.0 +- 0.4 mag.

  5. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    International Nuclear Information System (INIS)

    Ghebremedhin, A; Taber, M; Koss, P; Camargo, G; Patyal, B; Ebstein, S

    2016-01-01

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

  6. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Ghebremedhin, A; Taber, M; Koss, P; Camargo, G; Patyal, B [Loma Linda University Medical Center, Loma Linda, CA (United States); Ebstein, S [Lexitek, Inc, Wellesley, MA (United States)

    2016-06-15

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

  7. BVRI CCD photometry of the globular cluster NGC 6362

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.

    1986-01-01

    We have obtained 78 BVRI CCD frames with the 1.54 m Danish telescope at ESO, La Silla, and have constructed V vs B-V, V vs V-R, V vs R-I, V vs V-I, and V vs B-I color-magnitude diagrams in a 4' x 2X5 field of the globular cluster NGC 6362. From these five CMDs we find that the main-sequence turnoffs are all close to the same magnitude, namely V/sub TO/ = 18.75 +- 0.1, and the color turn- offs at B-V = 0.50 +- 0.02, V-R = 0.31 +- 0.02, R-I = 0.35 +- 0.02, V-I = 0.68 +- 0.02, and B-I = 1.18 +- 0.03. The magnitude difference between the turnoff and the horizontal branch for the five diagrams is ΔM/sub V/ = 3.40 +- 0.15 in excellent agreement with the value given by Sandage (1982). Using Y = 0.2, Z = 0.001 ([Fe/H] = -1.27), α = 1.65, a distance modulus of (m-M)/sub V/ = 14.74, and E(B-V) = 0.10, we find that the VandenBerg and Bell isochrones (1985) yield a consistent age for NGC 6362 in all colors indexes of 16 +- 1.5 x 10 9 yr. The solar distance to the cluster is 7.7 kpc and the galactic distance is 5.6 kpc assuming R 0 = 9 kpc

  8. Children's environmental chemical exposures in the USA, NHANES 2003-2012.

    Science.gov (United States)

    Hendryx, Michael; Luo, Juhua

    2018-02-01

    Children are vulnerable to environmental chemical exposures, but little is known about the extent of multiple chemical exposures among children. We analyzed biomonitoring data from five cycles (2003-2012) of the National Health and Nutrition Examination Survey (NHANES) to describe multiple chemical exposures in US children, examine levels of chemical concentrations present over time, and examine differences in chemical exposures by selected demographic groups. We analyzed data for 36 chemical analytes across five chemical classes in a sample of 4299 children aged 6-18. Classes included metals, pesticides, phthalates, phenols, and polycyclic aromatic hydrocarbons. We calculated the number and percent of chemicals detected and tested for secular trends over time in chemical concentrations. We compared log concentrations among groups defined by age, sex, race/ethnicity, and poverty using multiple linear regression models and report adjusted geometric means. Among a smaller subgroup of 733 children with data across chemical classes, we calculated the linear correlations within and between classes and conducted a principal component analysis. The percentage of children with detectable concentrations of an individual chemical ranged from 26 to 100%; the average was 93%, and 29 of 36 were detected in more than 90% of children. Concentrations of most tested chemicals were either unchanged or declined from earlier to more recent years. Many differences in concentrations were present by age, sex, poverty, and race/ethnicity categories. Within and between class correlations were all significant and positive, and the principal component analysis suggested a one factor solution, indicating that children exposed to higher levels of one chemical were exposed to higher levels of other chemicals. In conclusion, children in the USA are exposed to multiple simultaneous chemicals at uneven risk across socioeconomic and demographic groups. Further efforts to understand the effects of

  9. Multiple assessment methods of prenatal exposure to radio frequency radiation from telecommunication in the Mothers and Children’s Environmental Health (MOCEH study

    Directory of Open Access Journals (Sweden)

    Kyung-Hwa Choi

    2016-12-01

    Full Text Available Objectives: To evaluate prenatal exposure to radiofrequency radiation (RFR from telecommunication using a mobile phone questionnaire, operator data logs of mobile phone use and a personal exposure meter (PEM. Material and Methods: The study included 1228 mother–infants pairs from the Mothers and Children’s Environmental Health (MOCEH study – a multicenter prospective cohort study ongoing since 2006, in which participants were enrolled at ≤ 20 weeks of pregnancy, with a follow-up of a child birth and growth to assess the association between prenatal environmental exposure and children’s health. The questionnaire included the average calling frequency per day and the average calling time per day. An EME Spy 100 PEM was used to measure RFR among 269 pregnant women from November 2007 to August 2010. The operators’ log data were obtained from 21 participants. The Spearman’s correlation test was performed to evaluate correlation coefficient and 95% confidence intervals between the mobile phone use information from the questionnaire, operators’ log data, and data recorded by the PEM. Results: The operators’ log data and information from the self-reported questionnaire showed significantly high correlations in the average calling frequency per day (ρ = 0.6, p = 0.004 and average calling time per day (ρ = 0.5, p = 0.02. The correlation between information on the mobile phone use in the self-reported questionnaire and exposure index recorded by the PEM was poor. But correlation between the information of the operators’ log data and exposure index for transmission of mobile communication was significantly high: correlation coefficient (p-value was 0.44 (0.07 for calling frequency per day, and it was 0.49 (0.04 for calling time per day. Conclusions: The questionnaire information on the mobile phone use showed moderate to high quality. Using multiple methods for exposure assessment might be better than using only one method. Int J Occup

  10. Photon counting imaging and centroiding with an electron-bombarded CCD using single molecule localisation software

    International Nuclear Information System (INIS)

    Hirvonen, Liisa M.; Barber, Matthew J.; Suhling, Klaus

    2016-01-01

    Photon event centroiding in photon counting imaging and single-molecule localisation in super-resolution fluorescence microscopy share many traits. Although photon event centroiding has traditionally been performed with simple single-iteration algorithms, we recently reported that iterative fitting algorithms originally developed for single-molecule localisation fluorescence microscopy work very well when applied to centroiding photon events imaged with an MCP-intensified CMOS camera. Here, we have applied these algorithms for centroiding of photon events from an electron-bombarded CCD (EBCCD). We find that centroiding algorithms based on iterative fitting of the photon events yield excellent results and allow fitting of overlapping photon events, a feature not reported before and an important aspect to facilitate an increased count rate and shorter acquisition times.

  11. Aggregating human exposure to chemicals: An overview of tools and methodologies

    NARCIS (Netherlands)

    Delmaar JE; Engelen JGM van; AFSSET; SIR

    2007-01-01

    Available computer models for estimating the exposure to substances from multiple consumer products are not suited for this task. Consumers are daily exposed to chemical substances from consumer products. The level of this exposure has to be assessed to evaluate the consequences of exposure to a

  12. Multiple myeloma among atomic bomb survivors, Hiroshima and Nagasaki, 1950 - 76

    International Nuclear Information System (INIS)

    Ichimaru, Michito; Ishimaru, Toranosuke; Mikami, Motoko; Matsunaga, Masako.

    1979-10-01

    The relationship between atomic bomb exposure and the occurrence of multiple myeloma has been evaluated in a fixed cohort of approximately 100,000 A-bomb survivors and nonexposed controls during the period from October 1950 to December 1976. Analysis of these data revealed the standardized relative risk adjusted for city, sex, and age at the time of the bombs (ATB) to be significantly greater in the group of individuals who received 100 rad or more of radiation than in their controls. An excess risk became apparent in the high dose group about 20 years after exposure. The excess risk of multiple myeloma in those persons aged 20 - 59 ATB is estimated to be approximately 0.24 per million person-years per rad (PYR) in kerma dose and approximately 0.48 per million PYR in bone marrow dose. The interval between radiation exposure and the occurrence of an excess risk for multiple myeloma in the high dose population is considerably longer than that for leukemia. The cases of multiple myeloma observed in the high dose group showed no unusual clinical features. (author)

  13. [Multiple meningiomas].

    Science.gov (United States)

    Terrier, L-M; François, P

    2016-06-01

    Multiple meningiomas (MMs) or meningiomatosis are defined by the presence of at least 2 lesions that appear simultaneously or not, at different intracranial locations, without the association of neurofibromatosis. They present 1-9 % of meningiomas with a female predominance. The occurrence of multiple meningiomas is not clear. There are 2 main hypotheses for their development, one that supports the independent evolution of these tumors and the other, completely opposite, that suggests the propagation of tumor cells of a unique clone transformation, through cerebrospinal fluid. NF2 gene mutation is an important intrinsic risk factor in the etiology of multiple meningiomas and some exogenous risk factors have been suspected but only ionizing radiation exposure has been proven. These tumors can grow anywhere in the skull but they are more frequently observed in supratentorial locations. Their histologic types are similar to unique meningiomas of psammomatous, fibroblastic, meningothelial or transitional type and in most cases are benign tumors. The prognosis of these tumors is eventually good and does not differ from the unique tumors except for the cases of radiation-induced multiple meningiomas, in the context of NF2 or when diagnosed in children where the outcome is less favorable. Each meningioma lesion should be dealt with individually and their multiple character should not justify their resection at all costs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Simulation model of lung cancer incidence related to smoking and radon daughter exposure

    International Nuclear Information System (INIS)

    Stolowijk, J.A.J.

    1990-01-01

    A mathematical model of lung cancer and radon daughter exposure is presented. It is aimed to provide a quantitative estimate in the form of dose-effect relationship. The nature of the cigarette smoking and radon exposure interaction it is shown to be a multiplicative or sub-multiplicative function rather than a simpler model in which the effect of the two exposures would be summed. The model was written in the SAS programming language. An annotated listing of the program is given. 4 refs

  15. TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

    International Nuclear Information System (INIS)

    Goddu, S; Sun, B; Grantham, K; Zhao, T; Zhang, T; Bradley, J; Mutic, S

    2016-01-01

    Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal

  16. TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

    Energy Technology Data Exchange (ETDEWEB)

    Goddu, S; Sun, B; Grantham, K; Zhao, T; Zhang, T; Bradley, J; Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

  17. New sampling electronics using CCD for DIOGENE: a high multiplicity, 4 π detector for relativistic heavy ions

    International Nuclear Information System (INIS)

    Babinet, R.P.

    1987-01-01

    DIOGENE is a small time projection chamber which has been developed to study central collisions of relativistic heavy ions. The maximum multiplicity (up to 40 charged particles) that can be accepted by this detector is limited by the present electronics. In view of the heavier mass ions that should become readily available at the Saturne national facility (France), a new sampling electronics has been tested. In the first part of this talk they will present a brief description of the actual detector, insisting on the performances that have been effectively obtained with α-particles and Neon beams. The motivation for and characteristics of a renewed electronic set-up should thus appear more clearly. The second part of the talk is devoted to results of the tests that have been performed using charged couple devices. They will finally conclude on the future perspectives that have been opened by these developments

  18. APPLYING CCD CAMERAS IN STEREO PANORAMA SYSTEMS FOR 3D ENVIRONMENT RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    A. Sh. Amini

    2012-07-01

    Full Text Available Proper recontruction of 3D environments is nowadays needed by many organizations and applications. In addition to conventional methods the use of stereo panoramas is an appropriate technique to use due to simplicity, low cost and the ability to view an environment the way it is in reality. This paper investigates the ability of applying stereo CCD cameras for 3D reconstruction and presentation of the environment and geometric measuring among that. For this purpose, a rotating stereo panorama was established using two CCDs with a base-length of 350 mm and a DVR (digital video recorder box. The stereo system was first calibrated using a 3D test-field and used to perform accurate measurements. The results of investigating the system in a real environment showed that although this kind of cameras produce noisy images and they do not have appropriate geometric stability, but they can be easily synchronized, well controlled and reasonable accuracy (about 40 mm in objects at 12 meters distance from the camera can be achieved.

  19. Background study for the pn-CCD detector of CERN Axion Solar Telescope

    CERN Document Server

    Cebrián, S; Kuster, M.; Beltran, B.; Gomez, H.; Hartmann, R.; Irastorza, I. G.; Kotthaus, R.; Luzon, G.; Morales, J.; Ruz, J.; Struder, L.; Villar, J. A.

    2007-01-01

    The CERN Axion Solar Telescope (CAST) experiment searches for axions from the Sun converted into photons with energies up to around 10 keV via the inverse Primakoff effect in the high magnetic field of a superconducting Large Hadron Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in conjunction with an X-ray mirror optics is one of the three detectors used in CAST to register the expected photon signal. Since this signal is very rare and different background components (environmental gamma radiation, cosmic rays, intrinsic radioactive impurities in the set-up, ...) entangle it, a detailed study of the detector background has been undertaken with the aim to understand and further reduce the background level of the detector. The analysis is based on measured data taken during the Phase I of CAST and on Monte Carlo simulations of different background components. This study will show that the observed background level (at a rate of (8.00+-0.07)10^-5 counts/cm^2/s/keV between 1 and 7 keV) s...

  20. Advantages of the CCD camera measurements for profile and wear of cutting tools

    International Nuclear Information System (INIS)

    Varga, G; Dudas, I; Balajti, Z

    2005-01-01

    In our paper we prepared an evaluating study of which conclusions draw mainly two directions for our fields of research. On the one hand, this means the measuring of fix, standing workpieces, on the other hand this means geometrical measurement of moving tools. The first case seems to be solved in many respects (in general cases), but the second one is not completely worked out according to the relevant literature. The monitoring of tool wear, the determination of geometrical parameters (this is mainly in case of gear-generating tools) is not really widespread yet, mainly, if optical parameters have influence on the evaluating procedure (e.g. examination of profiles of grinding wheels). We show the elaboration of a process for the practical application of measuring techniques performed by image processing CCD cameras on the basis of wearing criteria of different cutting tools (drilling tool, turning tool). We have made a profile and cutting tool wear measuring program

  1. First-light instrument for the 3.6-m Devasthal Optical Telescope: 4Kx4K CCD Imager

    Science.gov (United States)

    Pandey, Shashi Bhushan; Yadav, Rama Kant Singh; Nanjappa, Nandish; Yadav, Shobhit; Reddy, Bheemireddy Krishna; Sahu, Sanjit; Srinivasan, Ramaiyengar

    2018-04-01

    As a part of in-house instrument developmental activity at ARIES, the 4Kx4K CCD Imager is designed and developed as a first-light instrument for the axial port of the 3.6-m Devasthal Optical Telescope (DOT). The f/9 beam of the telescope having a plate-scale of 6.4"/mm is utilized to conduct deeper photom-etry within the central 10' field of view. The pixel size of the blue-enhanced liquid nitrogen cooled STA4150 4Kx4K CCD chip is 15 μm, with options to select gain and speed values to utilize the dynamic range. Using the Imager, it is planned to image the central 6.5'x6.5' field of view of the telescope for various science goals by getting deeper images in several broad-band filters for point sources and objects with low surface brightness. The fully assembled Imager along with automated filter wheels having Bessel UBV RI and SDSS ugriz filters was tested in late 2015 at the axial port of the 3.6-m DOT. This instrument was finally mounted at the axial port of the 3.6-m DOT on 30 March 2016 when the telescope was technically activated jointly by the Prime Ministers of India and Belgium. It is expected to serve as a general purpose multi-band deep imaging instrument for a variety of science goals including studies of cosmic transients, active galaxies, star clusters and optical monitoring of X-ray sources discovered by the newly launched Indian space-mission called ASTROSAT, and follow-up of radio bright objects discovered by the Giant Meterwave Radio Telescope.

  2. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

    Energy Technology Data Exchange (ETDEWEB)

    Saotome, Naoya, E-mail: naosao@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji [Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2016-04-15

    Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

  3. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

    International Nuclear Information System (INIS)

    Saotome, Naoya; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji

    2016-01-01

    Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

  4. Reprocessing WFC3/IR Exposures Affected by Time-Variable Backgrounds

    Science.gov (United States)

    Brammer, G.

    2016-11-01

    The background seen in WFC3/IR observations frequently shows strong time-dependent behavior above the constant flux expected for zodiacal continuum light. This is often caused by an emission line of helium at 1.083 μm excited in the sun-illuminated upper atmosphere, when seen in the filters (F105W, F110W) and grisms (G102, G141) sensitive to the feature. The default behavior of the calwf3 pipeline assumes constant source-plus-background fluxes when it performs up-the-ramp fitting to identify cosmic rays and determine the average count rate within a MULTIACCUM IR exposure. calwf3 provides undesirable results in the presence of strongly variable backgrounds, primarily in the form of elevated and non-Gaussian noise in the FLT products. Here we describe methods to improve the noise properties of the reduced products. In the first, we simply turn off the calwf3 crcorr step, treating the IR detector as if it were a CCD, i.e., accumulating flux and reading it out at the end of the exposure. Next, we artificially flatten the ramps in the IMA products and then allow calwf3 to proceed as normal fitting the ramp and identifying CRs. Either of these procedures enable recovery of datasets otherwise corrupted beyond repair and have no discernible effects on photometry of sources in deep combined images.

  5. Detección automática de NEOs en imágenes CCD utilizando la transformada de Hough

    Science.gov (United States)

    Ruétalo, M.; Tancredi, G.

    El interés y la dedicación por los objetos que se acercan a la órbita de la Tierra (NEOs) ha aumentado considerablemente en los últimos años, tanto que se han iniciado varias campañas de búsqueda sistemática para aumentar la población identificada de éstos. El uso de placas fotográficas e identificación visual está siendo sustituído, progresivamente, por el uso de cámaras CCD y paquetes de detección automática de los objetos en las imágenes digitales. Una parte muy importante para la implementación exitosa de un programa automatizado de detección de este tipo es el desarrollo de algoritmos capaces de identificar objetos de baja relación señal-ruido y con requerimientos computacionales no elevados. En el presente trabajo proponemos la utilización de la transformada de Hough (utilizada en algunas áreas de visión artificial) para detectar automáticamente trazas, aproximadamente rectilíneas y de baja relación señal-ruido, en imágenes CCD. Desarrollamos una primera implementación de un algoritmo basado en ésta y lo probamos con una serie de imágenes reales conteniendo trazas con picos de señales de entre ~1 σ y ~3 σ por encima del nivel del ruido de fondo. El algoritmo detecta, sin inconvenientes, la mayoría de los casos y en tiempos razonablemente adecuados.

  6. Epigenetics, obesity and early-life cadmium or lead exposure.

    Science.gov (United States)

    Park, Sarah S; Skaar, David A; Jirtle, Randy L; Hoyo, Cathrine

    2017-01-01

    Obesity is a complex and multifactorial disease, which likely comprises multiple subtypes. Emerging data have linked chemical exposures to obesity. As organismal response to environmental exposures includes altered gene expression, identifying the regulatory epigenetic changes involved would be key to understanding the path from exposure to phenotype and provide new tools for exposure detection and risk assessment. In this report, we summarize published data linking early-life exposure to the heavy metals, cadmium and lead, to obesity. We also discuss potential mechanisms, as well as the need for complete coverage in epigenetic screening to fully identify alterations. The keys to understanding how metal exposure contributes to obesity are improved assessment of exposure and comprehensive establishment of epigenetic profiles that may serve as markers for exposures.

  7. Multiple image encryption scheme based on pixel exchange operation and vector decomposition

    Science.gov (United States)

    Xiong, Y.; Quan, C.; Tay, C. J.

    2018-02-01

    We propose a new multiple image encryption scheme based on a pixel exchange operation and a basic vector decomposition in Fourier domain. In this algorithm, original images are imported via a pixel exchange operator, from which scrambled images and pixel position matrices are obtained. Scrambled images encrypted into phase information are imported using the proposed algorithm and phase keys are obtained from the difference between scrambled images and synthesized vectors in a charge-coupled device (CCD) plane. The final synthesized vector is used as an input in a random phase encoding (DRPE) scheme. In the proposed encryption scheme, pixel position matrices and phase keys serve as additional private keys to enhance the security of the cryptosystem which is based on a 4-f system. Numerical simulations are presented to demonstrate the feasibility and robustness of the proposed encryption scheme.

  8. Image Alignment for Multiple Camera High Dynamic Range Microscopy.

    Science.gov (United States)

    Eastwood, Brian S; Childs, Elisabeth C

    2012-01-09

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability for HDR alignment of three exposure-robust techniques. We conclude that image alignment based on matching feature descriptors extracted from radiant power images from calibrated cameras yields the most accurate and robust solution. We demonstrate the use of this alignment technique in a high dynamic range video microscope that enables live specimen imaging with a greater level of detail than can be captured with a single camera.

  9. Minimizing radiation exposure during percutaneous nephrolithotomy.

    Science.gov (United States)

    Chen, T T; Preminger, G M; Lipkin, M E

    2015-12-01

    Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.

  10. On-board event processing algorithms for a CCD-based space borne X-ray spectrometer

    International Nuclear Information System (INIS)

    Chun, H.J.; Bowles, J.A.; Branduardi-Raymont, G.; Gowen, R.A.

    1996-01-01

    This paper describes two alternative algorithms which are applied to reduce the telemetry requirements for a Charge Coupled Device (CCD) based, space-borne, X-ray spectrometer by on-board reconstruction of the X-ray events split over two or more adjacent pixels. The algorithms have been developed for the Reflection Grating Spectrometer (RGS) on the X-ray multi-mirror (XMM) mission, the second cornerstone project in the European Space Agency's Horizon 2000 programme. The overall instrument and some criteria which provide the background of the development of the algorithms, implemented in Tartan ADA on an MA31750 microprocessor, are described. The on-board processing constraints and requirements are discussed, and the performances of the algorithms are compared. Test results are presented which show that the recursive implementation is faster and has a smaller executable file although it uses more memory because of its stack requirements. (orig.)

  11. Cesium transport across flat sheet supported liquid membrane containing CCD in NPOE-dodecane mixture

    International Nuclear Information System (INIS)

    Kandwal, P.; Mohapatra, P.K.

    2012-01-01

    137 Cs is an important fission product of concern for separation scientists working in the area of radioactive waste management. Removal of this long lived heat and gamma ray emitting radionuclides (t 1/2 = 30.2 y) from radioactive waste would drastically bring down the MANREM problem. In addition to this, the recovered cesium can find applications in irradiators for sterilization of foods, medical accessories, sewage sludge treatment, etc. Chlorinated cobalt dicarbollide (CCD) in nitrobenzene and xylene mixture as the diluent has been used for the extraction of radio-cesium from acidic wastes. Other studies have used phenyl trifluoromethylsulfone (FS-13) as the diluent and have been used for supported liquid membrane (SLM) based separation methods which not only have the advantage of simultaneous extraction and stripping, but also drastically cut down the VOC inventory which is welcome from environmental concern point of view

  12. Increasing the understanding of chemical concepts: The effectiveness of multiple exposures

    Science.gov (United States)

    Bius, Janet H.

    Chemistry is difficult because it has multilevels of knowledge with each level presenting challenges in vocabulary, abstract thinking, and symbolic language. Students have to be able to transfer between levels to understand the concepts and the theoretical models of chemistry. The cognitive theories of constructivism and cognitive-load theory are used to explain the difficulties novice learners have with the subject of chemistry and methods to increase success for students. The relationship between external representations, misconceptions and topics on the success of students are addressed. If students do not know the formalisms associated with chemical diagrams and graphs, the representations will decrease student success. Misconceptions can be formed when new information is interpreted based on pre-existing knowledge that is faulty. Topics with large amount of interacting elements that must be processed simultaneously are considered difficult to understand. New variables were created to measure the number of times a student is exposed to a chemical concept. Each variable was coded according to topic and learning environment, which are the lecture and laboratory components of the course, homework assignments and textbook examples. The exposure variables are used to measure the success rate of students on similar exam questions. Question difficulty scales were adapted for this project from those found in the chemical education literature. The exposure variables were tested on each level of the difficulty scales to determine their effect at decreasing the cognitive demand of these questions. The subjects of this study were freshmen science majors at a large Midwest university. The effects of the difficulty scales and exposure variables were measured for those students whose exam scores were in the upper one-fourth percentile, for students whose test scores were in the middle one-half percentile, and the lower one-fourth percentile are those students that scored the

  13. The use of discriminant analysis for evaluation of early-response multiple biomarkers of radiation exposure using non-human primate 6-Gy whole-body radiation model

    Energy Technology Data Exchange (ETDEWEB)

    Ossetrova, N.I. [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: ossetrova@afrri.usuhs.mil; Farese, A.M.; MacVittie, T.J. [Marlene and Stewart Greenebaum Cancer Center, Bressler Research Building, Room 7-039, University of Maryland-Baltimore, 655 West Baltimore Street, Baltimore, MD 21201 (United States); Manglapus, G.L.; Blakely, W.F. [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2007-07-15

    The present need to rapidly identify severely irradiated individuals in mass-casualty and population-monitoring scenarios prompted an evaluation of potential protein biomarkers to provide early diagnostic information after exposure. The level of specific proteins measured using immunodiagnostic technologies may be useful as protein biomarkers to provide early diagnostic information for acute radiation exposures. Herein we present results from on-going studies using a non-human primate (NHP) 6-Gy X-rays ( 0.13Gymin{sup -1}) whole-body radiation model. Protein targets were measured by enzyme-linked immunosorbent assay (ELISA) in blood plasma before, 1, and 2 days after exposure. Exposure of 10 NHPs to 6 Gy resulted in the up-regulation of plasma levels of (a) p21 WAF1/CIP1, (b) interleukin 6 (IL-6), (c) tissue enzyme salivary {alpha}-amylase, and (d) C-reactive protein. Data presented show the potential utility of protein biomarkers selected from distinctly different pathways to detect radiation exposure. A correlation analysis demonstrated strong correlations among different combinations of four candidate radiation-responsive blood protein biomarkers. Data analyzed with use of multivariate discriminant analysis established very successful separation of NHP groups: 100% discrimination power for animals with correct classification for separation between groups before and 1 day after irradiation, and 95% discrimination power for separation between groups before and 2 days after irradiation. These results also demonstrate proof-in-concept that multiple protein biomarkers provide early diagnostic information to the medical community, along with classical biodosimetric methodologies, to effectively manage radiation casualty incidents.

  14. Detection of rib fractures in an abused infant using digital radiography: a laboratory study

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, Paul K. [Department of Radiology, UMASS Memorial Health Care, 55 Lake Avenue North, Worcester, MA 01655 (United States); O' Connor, Brian; Nimkin, Katherine [Department of Pediatric Radiology, New England Medical Center, 750 Washington Street, Boston, MA 02111 (United States); Rayder, Shawn M. [Department of Radiology, Cape Cod Hospital, 12 Park Street, Hyannis, MA 02601-5203 (United States); Spevak, Melissa R. [Department of Radiology, Johns Hopkins Hospital, 600 N. Wolfe Street, Baltimore, MD 21287 (United States); Belanger, Patricia L. [University of Massachusetts, Amherst, MA 01003 (United States); Getty, David J. [BBNT Solutions LLC, 10 Moulton Street, Cambridge, MA 02138 (United States); Karellas, Andrew [Department of Radiology, University of Mass. Medical School, Lake Avenue North, Worcester, MA 01655 (United States)

    2002-12-01

    To assess the diagnostic performance of digital radiography using charge-coupled device (CCD) technology in the detection of rib fracture in infant abuse.Materials and methods. Four fractured posterior rib arcs and eight normal ribs removed at autopsy from a 10-month-old abused infant were radiographed using a CCD prototype, four clinical film-screen systems, and direct-exposure film. Each rib was viewed with these six systems in nine different projections. The resultant 648 images were assessed for probability of fracture (0-100%) by four pediatric radiologists. The calculated area under the resultant ROC curves (A{sub z}) for the CCD was compared with those obtained with direct-exposure, high-detail, medium and fast film-screen radiographic systems. The mean A{sub z} for the CCD (0.937) fell within the range of the high-detail systems (0.934-0.940) and was significantly higher (p<0.05) than the medium and fast system (0.861 and 0.858, respectively). Despite a lower spatial resolution than direct-exposure film (7 line pairs per millimeter vs. >20 line pairs per millimeter) the CCD performance was comparable (A{sub z}=0.944 vs. 0.937). The similar performance can be explained by the higher contrast resolution of the digital technology. This study indicates that in the ex vivo setting, digital radiology can perform comparably to high-detail film-screen imaging. The findings suggest that digital radiography has the potential to replace film-screen imaging in the evaluation of inflicted skeletal injury in infants. (orig.)

  15. Traumatic exposure and posttraumatic stress disorder among flood victims: Testing a multiple mediating model.

    Science.gov (United States)

    Quan, Lijuan; Zhen, Rui; Yao, Benxian; Zhou, Xiao

    2017-05-01

    A total of 187 flood victims from Wuhu, a Chinese city affected most severely by a flood during July 2016, were selected to complete self-report measures of traumatic exposure, feelings of safety, fear, posttraumatic negative cognition, and posttraumatic stress disorder. The results found that traumatic exposure could directly predict posttraumatic stress disorder. Besides, traumatic exposure had indirect prediction on posttraumatic stress disorder through three ways, including a one-step path of negative self-cognition, a two-step path from feelings of safety to fear, and a three-step path from feelings of safety to negative self-cognition via fear. Implications and future directions are correspondingly discussed.

  16. An analysis of CCD images of the coma of Comet Halley. Final report, October 1989-September 1990

    International Nuclear Information System (INIS)

    Combi, M.

    1990-12-01

    The analysis of selected CCD images of the coma of comet P/Halley is presented. The images were taken using specially designed filters that isolate regions of a comet's spectrum such that only sunlight which has been scattered by the dust in the coma is recorded. The modeling analysis objective is to make use of the skills developed in the development of Monte Carlo particle trajectory models for the distributions of gas species in cometary comae and to use those models as a basis for a new dust coma model. This model will include a self-consistant picture of the time-dependent dusty-gas dynamics of the inner coma and the three-dimensional time-dependent trajectories of the dust particles under the influence of solar gravity and solar radiation pressure in the outer coma. The model is intended to be used as a tool to analyze selected images from the two sets of CCD images with the hope that it will help the understanding of the effects of a number of important processes on the spatial morphology of the observed dust coma. The processes of importance to the observed dust coma include: (1) the dust particle size distribution function; (2) the terminal velocities of various sized dust particles in the inner coma; (3) the radiation scattering properties of dust particles, which are important both in terms of the observe scattered radiation and the radiation pressure acceleration on dust particles; (4) the fragmentation and/or vaporization of dust particles; and (5) the relative importance of CHON and silicate dust particles as they contribute both to the dusty-gasdynamics in the inner coma (that produce the dust particle terminal velocities) and to the observed spatial morphology on the outer dust coma

  17. Large-scale recovery of an endangered amphibian despite ongoing exposure to multiple stressors

    Science.gov (United States)

    Knapp, Roland A.; Fellers, Gary M.; Kleeman, Patrick M.; Miller, David A. W.; Vrendenburg, Vance T.; Rosenblum, Erica Bree; Briggs, Cheryl J.

    2016-01-01

    Amphibians are one of the most threatened animal groups, with 32% of species at risk for extinction. Given this imperiled status, is the disappearance of a large fraction of the Earth’s amphibians inevitable, or are some declining species more resilient than is generally assumed? We address this question in a species that is emblematic of many declining amphibians, the endangered Sierra Nevada yellow-legged frog (Rana sierrae). Based on >7,000 frog surveys conducted across Yosemite National Park over a 20-y period, we show that, after decades of decline and despite ongoing exposure to multiple stressors, including introduced fish, the recently emerged disease chytridiomycosis, and pesticides, R. sierrae abundance increased sevenfold during the study and at a rate of 11% per year. These increases occurred in hundreds of populations throughout Yosemite, providing a rare example of amphibian recovery at an ecologically relevant spatial scale. Results from a laboratory experiment indicate that these increases may be in part because of reduced frog susceptibility to chytridiomycosis. The disappearance of nonnative fish from numerous water bodies after cessation of stocking also contributed to the recovery. The large-scale increases in R. sierrae abundance that we document suggest that, when habitats are relatively intact and stressors are reduced in their importance by active management or species’ adaptive responses, declines of some amphibians may be partially reversible, at least at a regional scale. Other studies conducted over similarly large temporal and spatial scales are critically needed to provide insight and generality about the reversibility of amphibian declines at a global scale.

  18. Single-exposure color digital holography

    Science.gov (United States)

    Feng, Shaotong; Wang, Yanhui; Zhu, Zhuqing; Nie, Shouping

    2010-11-01

    In this paper, we report a method for color image reconstruction by recording only one single multi-wavelength hologram. In the recording process, three lasers of different wavelengths emitting in the red, green and blue regions are used for illuminating on the object and the object diffraction fields will arrive at the hologram plane simultaneously. Three reference beams with different spatial angles will interfere with the corresponding object diffraction fields on the hologram plane, respectively. Finally, a series of sub-holograms incoherently overlapped on the CCD to be recorded as a multi-wavelength hologram. Angular division multiplexing is employed to reference beams so that the spatial spectra of the multiple recordings will be separated in the Fourier plane. In the reconstruction process, the multi-wavelength hologram will be Fourier transformed into its Fourier plane, where the spatial spectra of different wavelengths are separated and can be easily extracted by employing frequency filtering. The extracted spectra are used to reconstruct the corresponding monochromatic complex amplitudes, which will be synthesized to reconstruct the color image. For singleexposure recording technique, it is convenient for applications on the real-time image processing fields. However, the quality of the reconstructed images is affected by speckle noise. How to improve the quality of the images needs for further research.

  19. Sunscreens with broad-spectrum absorption decrease the trans TO cis photoisomerization of urocanic acid in the human stratum corneum after multiple UV light exposures

    International Nuclear Information System (INIS)

    Krien, P.M.; Moyal, D.

    1994-01-01

    The trans to cis photoisomerization of urocanic acid (UCA) in skin is considered to play an important role in the mechanism of immunosuppression. We have investigated the effects of skin type and various sunscreens with low sun protection factor (SPF) on the UV-induced cis-UCA formation in human skin after exposure to artificial UV light. The rate of cis-UCA formation depends little on the skin type and is reduced by topical application of sunscreens. The rate of cis-UCA formation decreases with increasing SPF and only broad-spectrum, highly protective sunscreens offer protection against the UV-induced formation of cis-UCA, which accumulates in the stratum corneum after multiple UV exposures. A theoretical approach to estimate the distribution of cis-UCA after irradiation indicates that this compound may diffuse into the deeper layers of the epidermis with D ∼ 10 -17 m 2 /s, and that its elimination from the stratum corneum is mainly due to desquamation. (author)

  20. Multiple-Strain Approach and Probabilistic Modeling of Consumer Habits in Quantitative Microbial Risk Assessment: A Quantitative Assessment of Exposure to Staphylococcal Enterotoxin A in Raw Milk.

    Science.gov (United States)

    Crotta, Matteo; Rizzi, Rita; Varisco, Giorgio; Daminelli, Paolo; Cunico, Elena Cosciani; Luini, Mario; Graber, Hans Ulrich; Paterlini, Franco; Guitian, Javier

    2016-03-01

    Quantitative microbial risk assessment (QMRA) models are extensively applied to inform management of a broad range of food safety risks. Inevitably, QMRA modeling involves an element of simplification of the biological process of interest. Two features that are frequently simplified or disregarded are the pathogenicity of multiple strains of a single pathogen and consumer behavior at the household level. In this study, we developed a QMRA model with a multiple-strain approach and a consumer phase module (CPM) based on uncertainty distributions fitted from field data. We modeled exposure to staphylococcal enterotoxin A in raw milk in Lombardy; a specific enterotoxin production module was thus included. The model is adaptable and could be used to assess the risk related to other pathogens in raw milk as well as other staphylococcal enterotoxins. The multiplestrain approach, implemented as a multinomial process, allowed the inclusion of variability and uncertainty with regard to pathogenicity at the bacterial level. Data from 301 questionnaires submitted to raw milk consumers were used to obtain uncertainty distributions for the CPM. The distributions were modeled to be easily updatable with further data or evidence. The sources of uncertainty due to the multiple-strain approach and the CPM were identified, and their impact on the output was assessed by comparing specific scenarios to the baseline. When the distributions reflecting the uncertainty in consumer behavior were fixed to the 95th percentile, the risk of exposure increased up to 160 times. This reflects the importance of taking into consideration the diversity of consumers' habits at the household level and the impact that the lack of knowledge about variables in the CPM can have on the final QMRA estimates. The multiple-strain approach lends itself to use in other food matrices besides raw milk and allows the model to better capture the complexity of the real world and to be capable of geographical