WorldWideScience

Sample records for multiple errands test

  1. In-home contextual reality: a qualitative analysis using the Multiple Errands Test Home Version (MET-Home).

    Science.gov (United States)

    Burns, Suzanne Perea; Pickens, Noralyn Davel; Dawson, Deirdre R; Perea, Jaimee D; Vas, Asha K; Marquez de la Plata, Carlos; Neville, Marsha

    2018-02-06

    Adults with stroke frequently experience executive dysfunction. Despite the range of assessments that examine the effects of executive dysfunction on daily tasks, there remains a paucity of literature that examines the influence of the environment on performance in the community. The MET-Home is an ecologically valid assessment for examining post-stroke executive dysfunction in the home environment. This qualitative study explores the relationship between the environment and MET-Home performance among home-dwelling adults with stroke and matched controls. Using a descriptive qualitative approach, we analysed video, interview, and observation notes from a MET-Home validation study. An overarching theme of interplay between everyday task performance and the home environment produced further themes: naturalistically emerging supports and barriers and environment as strategy. Within naturalistically emerging supports and barriers, five contextual sub-themes were discovered: physical environment, social environment, temporal context, virtual context, and personal context. Within environment as strategy, we identified four sub-themes: reducing distractions, using everyday technologies, planning in context, and seeking social support. These findings extend the conceptualisation of how we evaluate executive dysfunction in the context of the community to also consider the inherent influence of the environment.

  2. Investigating Multitasking in High-Functioning Adolescents with Autism Spectrum Disorders Using the Virtual Errands Task

    Science.gov (United States)

    Rajendran, Gnanathusharan; Law, Anna S.; Logie, Robert H.; van der Meulen, Marian; Fraser, Diane; Corley, Martin

    2011-01-01

    Using a modified version of the Virtual Errands Task (VET; McGeorge et al. in "Presence-Teleop Virtual Environ" 10(4):375-383, 2001), we investigated the executive ability of multitasking in 18 high-functioning adolescents with ASD and 18 typically developing adolescents. The VET requires multitasking (Law et al. in "Acta Psychol" 122(1):27-44,…

  3. The disruptive effects of pain on multitasking in a virtual errands task.

    Science.gov (United States)

    Moore, David J; Law, Anna S

    2017-07-01

    Pain is known to have a disruptive effect on cognitive performance, but prior studies have used highly constrained laboratory tasks that lack ecological validity. In everyday life people are required to complete more complex sets of tasks, prioritising task completion and recalling lists of tasks which need to be completed, and these tasks continue to be attempted during episodes or states of pain. The present study therefore examined the impact of thermal induced pain on a simulated errand task. Fifty-five healthy adults (36 female) performed the Edinburgh Virtual Errands Task (EVET) either during a painful thermal sensation or with no concurrent pain. Participants also completed the Experience of Cognitive Intrusion of Pain (ECIP) questionnaire to measure their self-reported cognitive impact of pain in general life. Participants who completed the EVET task in pain and who self-reported high intrusion of pain made significantly more errors than those who reported lower intrusion on the ECIP. Findings here support the growing literature that suggests that pain has a significant impact on cognitive performance. Furthermore, these findings support the developing literature suggesting that this relationship is complex when considering real world cognition, and that self-report on the ECIP relates well to performance on a task designed to reflect the complexities of everyday living. If extrapolated to chronic pain populations, these data suggest that pain during complex multitasking performance may have a significant impact on the number of errors made. For people highly vulnerable to cognitive intrusion by pain, this may result in errors such as selecting the wrong location or item to perform tasks, or forgetting to perform these tasks at the correct time. If these findings are shown to extend to chronic pain populations then occupational support to manage complex task performance, using for example diaries/electronic reminders, may help to improve everyday abilities

  4. Multiple Improvements of Multiple Imputation Likelihood Ratio Tests

    OpenAIRE

    Chan, Kin Wai; Meng, Xiao-Li

    2017-01-01

    Multiple imputation (MI) inference handles missing data by first properly imputing the missing values $m$ times, and then combining the $m$ analysis results from applying a complete-data procedure to each of the completed datasets. However, the existing method for combining likelihood ratio tests has multiple defects: (i) the combined test statistic can be negative in practice when the reference null distribution is a standard $F$ distribution; (ii) it is not invariant to re-parametrization; ...

  5. Common pitfalls in statistical analysis: The perils of multiple testing

    Science.gov (United States)

    Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc

    2016-01-01

    Multiple testing refers to situations where a dataset is subjected to statistical testing multiple times - either at multiple time-points or through multiple subgroups or for multiple end-points. This amplifies the probability of a false-positive finding. In this article, we look at the consequences of multiple testing and explore various methods to deal with this issue. PMID:27141478

  6. Kruskal-Wallis Test in Multiple Comparisons

    OpenAIRE

    Parys, Dariusz

    2009-01-01

    In this paper we show that the Kruskal-Wallis test can be transform to quadratic form among the Mann-Whitney or Kendal τ au concordance measures between pairs of treatments. A multiple comparisons procedure based on patterns of transitive ordering among treatments is implement. We also consider the circularity and non-transitive effects. Statystyka testu Kruskala-Wallisa przedstawiona jest w postaci formy kwadratowej z użyciem statystyki Manna-Whitneya lub miar konkordacji τ au Kendalla. N...

  7. The positive and negative consequences of multiple-choice testing.

    Science.gov (United States)

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  8. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  9. Multiple Site Damage in Flat Panel Testing

    National Research Council Canada - National Science Library

    Shrage, Daniel

    2000-01-01

    This report aimed to experimentally verify analytical models that predict the residual strength of representative aircraft structures, such as wide panels, that are subjected to Multiple Site Damage (MSD...

  10. A test for the parameters of multiple linear regression models ...

    African Journals Online (AJOL)

    A test for the parameters of multiple linear regression models is developed for conducting tests simultaneously on all the parameters of multiple linear regression models. The test is robust relative to the assumptions of homogeneity of variances and absence of serial correlation of the classical F-test. Under certain null and ...

  11. The Multiple Tasks Test: development and normal strategies.

    NARCIS (Netherlands)

    Bloem, B.R.; Valkenburg, V.V.; Slabbekoorn, M.; Willemsen, M.D.

    2001-01-01

    Simultaneous challenge of posture and cognition ("dual tasks") may predict falls better than tests of isolated components of postural control. We describe a new balance test (the Multiple Tasks Test, MTT) which (1) is based upon simultaneous assessment of multiple (>2) postural components; (2)

  12. Optimizing Multiple-Choice Tests as Learning Events

    Science.gov (United States)

    Little, Jeri Lynn

    2011-01-01

    Although generally used for assessment, tests can also serve as tools for learning--but different test formats may not be equally beneficial. Specifically, research has shown multiple-choice tests to be less effective than cued-recall tests in improving the later retention of the tested information (e.g., see meta-analysis by Hamaker, 1986),…

  13. Multiple Choice Testing and the Retrieval Hypothesis of the Testing Effect

    Science.gov (United States)

    Sensenig, Amanda E.

    2010-01-01

    Taking a test often leads to enhanced later memory for the tested information, a phenomenon known as the "testing effect". This memory advantage has been reliably demonstrated with recall tests but not multiple choice tests. One potential explanation for this finding is that multiple choice tests do not rely on retrieval processes to the same…

  14. A Review of Multiple Hypothesis Testing in Otolaryngology Literature

    Science.gov (United States)

    Kirkham, Erin M.; Weaver, Edward M.

    2018-01-01

    Objective Multiple hypothesis testing (or multiple testing) refers to testing more than one hypothesis within a single analysis, and can inflate the Type I error rate (false positives) within a study. The aim of this review was to quantify multiple testing in recent large clinical studies in the otolaryngology literature and to discuss strategies to address this potential problem. Data sources Original clinical research articles with >100 subjects published in 2012 in the four general otolaryngology journals with the highest Journal Citation Reports 5-year impact factors. Review methods Articles were reviewed to determine whether the authors tested greater than five hypotheses in at least one family of inferences. For the articles meeting this criterion for multiple testing, Type I error rates were calculated and statistical correction was applied to the reported results. Results Of the 195 original clinical research articles reviewed, 72% met the criterion for multiple testing. Within these studies, there was a mean 41% chance of a Type I error and, on average, 18% of significant results were likely to be false positives. After the Bonferroni correction was applied, only 57% of significant results reported within the articles remained significant. Conclusion Multiple testing is common in recent large clinical studies in otolaryngology and deserves closer attention from researchers, reviewers and editors. Strategies for adjusting for multiple testing are discussed. PMID:25111574

  15. Accelerated spike resampling for accurate multiple testing controls.

    Science.gov (United States)

    Harrison, Matthew T

    2013-02-01

    Controlling for multiple hypothesis tests using standard spike resampling techniques often requires prohibitive amounts of computation. Importance sampling techniques can be used to accelerate the computation. The general theory is presented, along with specific examples for testing differences across conditions using permutation tests and for testing pairwise synchrony and precise lagged-correlation between many simultaneously recorded spike trains using interval jitter.

  16. [Plagiarism. A fools' errand.

    Science.gov (United States)

    Jefferson, Tom; De Fiore, Luca

    2017-01-01

    An old Italian proverb states that lies have short legs. In other words, in the end you get found out. This is exactly what happened to an Italian researcher who acted as a referee for a manuscript submitted in 2015 to Annals of Internal Medicine. After a negative report (which presumably led to the rejection of the submission) he submitted a manuscript which was essentially the same. But he and his accomplices got found out and paraded in front of the world in an earth-shatteringly polite "Dear Plagiarist" letter by the first robbed author: Dr Michael Dansinger. Dr Dansiger's letter is a model of polite logic and an ethical masterpiece, the fake article got retracted and the thief's institution contacted. No reply so far, a depressingly familiar theme in contemporary research. We wonder why we carry on with a system which is completely broken. Commercial interests, reporting bias, secrecy, ethically dubious studies and inertia are the ingredients of contemporary research and publication practices. Editorial peer review, a scholarly practice originating in a more genteel era, is clearly unable to do much other than lend a very thin veneer of credibility to this pandemic of junk which is threatening healthcare budgets and the ethics of the next generation of researchers. We need a complete reform of the system which could give back some credibility to the "e" of evidence-based medicine. Complete lawful transparency, public reimbursement of interventions only on the basis of independently generated evidence and research ethics as a part of an international curriculum for budding researchers are urgently needed. These should be linked to publishers' complete disclosure of their sources of income and custodial sentences for those who abuse positions of trust. Meanwhile, stay away from anything implausible and non-replicable (as they probably are).

  17. A new bootstrap test for multiple assets joint risk testing

    NARCIS (Netherlands)

    Ardia, David; Gatarek, Lukasz; Hoogerheide, Lennart F.

    2017-01-01

    In this paper, a novel simulation-based methodology is proposed to test the validity of a set of marginal time series models, where the dependence structure between the time series is taken directly from the observed data. The procedure is useful when one wants to summarize the test results for

  18. Testing for Nonuniform Differential Item Functioning with Multiple Indicator Multiple Cause Models

    Science.gov (United States)

    Woods, Carol M.; Grimm, Kevin J.

    2011-01-01

    In extant literature, multiple indicator multiple cause (MIMIC) models have been presented for identifying items that display uniform differential item functioning (DIF) only, not nonuniform DIF. This article addresses, for apparently the first time, the use of MIMIC models for testing both uniform and nonuniform DIF with categorical indicators. A…

  19. Multiple-vent programme to test the pressure suppression system

    International Nuclear Information System (INIS)

    Aust, E.; Schwan, H.; Vollbrandt, I.

    1979-01-01

    Three pre-tests with a multiple vent configuration have been performed at the GKSS pressure suppression test facility. First test results indicate significant chugging events with occur periodically with 0.4 to 0.2 Hz. These events appear simultaneously in less than 10 ms at the exit of the three vent pipes and cause pressure pulses in the range of 3 bar. This report gives a short description of the test facility and presents the boundary conditions of the test facility and presents the boundary conditions of the three pre-tests, test results and a first valuation of the experimental informations. (orig.) [de

  20. Optimizing multiple-choice tests as tools for learning.

    Science.gov (United States)

    Little, Jeri L; Bjork, Elizabeth Ligon

    2015-01-01

    Answering multiple-choice questions with competitive alternatives can enhance performance on a later test, not only on questions about the information previously tested, but also on questions about related information not previously tested-in particular, on questions about information pertaining to the previously incorrect alternatives. In the present research, we assessed a possible explanation for this pattern: When multiple-choice questions contain competitive incorrect alternatives, test-takers are led to retrieve previously studied information pertaining to all of the alternatives in order to discriminate among them and select an answer, with such processing strengthening later access to information associated with both the correct and incorrect alternatives. Supporting this hypothesis, we found enhanced performance on a later cued-recall test for previously nontested questions when their answers had previously appeared as competitive incorrect alternatives in the initial multiple-choice test, but not when they had previously appeared as noncompetitive alternatives. Importantly, however, competitive alternatives were not more likely than noncompetitive alternatives to be intruded as incorrect responses, indicating that a general increased accessibility for previously presented incorrect alternatives could not be the explanation for these results. The present findings, replicated across two experiments (one in which corrective feedback was provided during the initial multiple-choice testing, and one in which it was not), thus strongly suggest that competitive multiple-choice questions can trigger beneficial retrieval processes for both tested and related information, and the results have implications for the effective use of multiple-choice tests as tools for learning.

  1. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    Directory of Open Access Journals (Sweden)

    Zongyue Yu

    2014-01-01

    Full Text Available A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testing plan including both the high temperatures and low temperatures is designed, and a statistical analysis method is developed. The reliability function of the product with multiple failure modes under variable working conditions is given by the proposed statistical analysis method. Finally, a numerical example is studied to illustrate the proposed accelerated testing. The results show that the proposed accelerated testing is rather efficient.

  2. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    OpenAIRE

    Zongyue Yu; Zhiqian Ren; Junyong Tao; Xun Chen

    2014-01-01

    A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testi...

  3. Multiple-choice test of energy and momentum concepts

    OpenAIRE

    Singh, Chandralekha; Rosengrant, David

    2016-01-01

    We investigate student understanding of energy and momentum concepts at the level of introductory physics by designing and administering a 25-item multiple choice test and conducting individual interviews. We find that most students have difficulty in qualitatively interpreting basic principles related to energy and momentum and in applying them in physical situations.

  4. Kernel Machine SNP-set Testing under Multiple Candidate Kernels

    Science.gov (United States)

    Wu, Michael C.; Maity, Arnab; Lee, Seunggeun; Simmons, Elizabeth M.; Harmon, Quaker E.; Lin, Xinyi; Engel, Stephanie M.; Molldrem, Jeffrey J.; Armistead, Paul M.

    2013-01-01

    Joint testing for the cumulative effect of multiple single nucleotide polymorphisms grouped on the basis of prior biological knowledge has become a popular and powerful strategy for the analysis of large scale genetic association studies. The kernel machine (KM) testing framework is a useful approach that has been proposed for testing associations between multiple genetic variants and many different types of complex traits by comparing pairwise similarity in phenotype between subjects to pairwise similarity in genotype, with similarity in genotype defined via a kernel function. An advantage of the KM framework is its flexibility: choosing different kernel functions allows for different assumptions concerning the underlying model and can allow for improved power. In practice, it is difficult to know which kernel to use a priori since this depends on the unknown underlying trait architecture and selecting the kernel which gives the lowest p-value can lead to inflated type I error. Therefore, we propose practical strategies for KM testing when multiple candidate kernels are present based on constructing composite kernels and based on efficient perturbation procedures. We demonstrate through simulations and real data applications that the procedures protect the type I error rate and can lead to substantially improved power over poor choices of kernels and only modest differences in power versus using the best candidate kernel. PMID:23471868

  5. Conservatism implications of shock test tailoring for multiple design environments

    Science.gov (United States)

    Baca, Thomas J.; Bell, R. Glenn; Robbins, Susan A.

    1987-01-01

    A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ranked peak acceleration data in terms of an Index of Conservation (IOC) and an Overtest Factor (OTF). The multi-environment conservation analysis addresses the issue of both absolute and average conservation. The method is demonstrated in a case where four laboratory tests have been specified to qualify a component which must survive seven different field environments. Final judgment of the tailored test specification is shown to require an understanding of the predominant failure modes of the test item.

  6. Planned Hypothesis Tests Are Not Necessarily Exempt From Multiplicity Adjustment

    Directory of Open Access Journals (Sweden)

    Andrew V. Frane

    2015-10-01

    Full Text Available Scientific research often involves testing more than one hypothesis at a time, which can inflate the probability that a Type I error (false discovery will occur. To prevent this Type I error inflation, adjustments can be made to the testing procedure that compensate for the number of tests. Yet many researchers believe that such adjustments are inherently unnecessary if the tests were “planned” (i.e., if the hypotheses were specified before the study began. This longstanding misconception continues to be perpetuated in textbooks and continues to be cited in journal articles to justify disregard for Type I error inflation. I critically evaluate this myth and examine its rationales and variations. To emphasize the myth’s prevalence and relevance in current research practice, I provide examples from popular textbooks and from recent literature. I also make recommendations for improving research practice and pedagogy regarding this problem and regarding multiple testing in general.

  7. Bees Algorithm for Construction of Multiple Test Forms in E-Testing

    Science.gov (United States)

    Songmuang, Pokpong; Ueno, Maomi

    2011-01-01

    The purpose of this research is to automatically construct multiple equivalent test forms that have equivalent qualities indicated by test information functions based on item response theory. There has been a trade-off in previous studies between the computational costs and the equivalent qualities of test forms. To alleviate this problem, we…

  8. Reliability of psychophysiological responses across multiple motion sickness stimulation tests

    Science.gov (United States)

    Stout, C. S.; Toscano, W. B.; Cowings, P. S.

    1995-01-01

    Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

  9. Integrative set enrichment testing for multiple omics platforms

    Directory of Open Access Journals (Sweden)

    Poisson Laila M

    2011-11-01

    Full Text Available Abstract Background Enrichment testing assesses the overall evidence of differential expression behavior of the elements within a defined set. When we have measured many molecular aspects, e.g. gene expression, metabolites, proteins, it is desirable to assess their differential tendencies jointly across platforms using an integrated set enrichment test. In this work we explore the properties of several methods for performing a combined enrichment test using gene expression and metabolomics as the motivating platforms. Results Using two simulation models we explored the properties of several enrichment methods including two novel methods: the logistic regression 2-degree of freedom Wald test and the 2-dimensional permutation p-value for the sum-of-squared statistics test. In relation to their univariate counterparts we find that the joint tests can improve our ability to detect results that are marginal univariately. We also find that joint tests improve the ranking of associated pathways compared to their univariate counterparts. However, there is a risk of Type I error inflation with some methods and self-contained methods lose specificity when the sets are not representative of underlying association. Conclusions In this work we show that consideration of data from multiple platforms, in conjunction with summarization via a priori pathway information, leads to increased power in detection of genomic associations with phenotypes.

  10. Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Elder, J.; Vandekamp, R.

    2011-02-10

    Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

  11. Training in multiple breath washout testing for respiratory physiotherapists.

    Science.gov (United States)

    O'Neill, Katherine; Elborn, J Stuart; Tunney, Michael M; O'Neill, Philip; Rowan, Stephen; Martin, Susan; Bradley, Judy M

    2018-03-01

    The development of multiple breath washout (MBW) testing in respiratory disease highlights the need for increased awareness amongst respiratory physiotherapists and a potential opportunity for professional development in the use of an important outcome measure for clinical trials. To rationalise how MBW may be a useful assessment tool for respiratory physiotherapists and to describe a local MBW training and certification programme for physiotherapists. The respiratory Multidisciplinary Team in the Belfast Health and Social Care Trust (BHSCT) identified a need for MBW testing to be available to facilitate clinical research and assessment. A 2day training programme consisting of prereading preparation, self-directed learning, theory presentations, practical demonstrations and hands-on practice was developed and delivered. All participants underwent a certification process. We have demonstrated the successful training and certification of clinical and research physiotherapists and encourage other respiratory physiotherapists to consider MBW test training. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  12. Operation of a nuclear test gage at low multiplications

    International Nuclear Information System (INIS)

    Baumann, N.P.

    1977-01-01

    The Nuclear Test Gage (NTG) at the Savannah River Plant is a subcritical multiplying facility (low k) with H 2 O moderator and 2.54-cm-diameter fuel slugs of 5 wt percent 235 U in aluminum alloy at a 4.285-cm triangular pitch. The core of the facility is 61-cm long with a normal diameter of 27 cm. The NTG is used for quality control of reactor components, such as 235 U-Al fuel tubes, Li--Al target tubes, control and safety rods, and miscellaneous special irradiation elements. A component is tested by passing it through an axial test port 11.63 cm in diameter. The ion chamber response from the resultant change in neutron source multiplication is then compared with corresponding responses from known standards

  13. A Spreadsheet Tool for Learning the Multiple Regression F-Test, T-Tests, and Multicollinearity

    Science.gov (United States)

    Martin, David

    2008-01-01

    This note presents a spreadsheet tool that allows teachers the opportunity to guide students towards answering on their own questions related to the multiple regression F-test, the t-tests, and multicollinearity. The note demonstrates approaches for using the spreadsheet that might be appropriate for three different levels of statistics classes,…

  14. Effects of dependence in high-dimensional multiple testing problems

    Directory of Open Access Journals (Sweden)

    van de Wiel Mark A

    2008-02-01

    Full Text Available Abstract Background We consider effects of dependence among variables of high-dimensional data in multiple hypothesis testing problems, in particular the False Discovery Rate (FDR control procedures. Recent simulation studies consider only simple correlation structures among variables, which is hardly inspired by real data features. Our aim is to systematically study effects of several network features like sparsity and correlation strength by imposing dependence structures among variables using random correlation matrices. Results We study the robustness against dependence of several FDR procedures that are popular in microarray studies, such as Benjamin-Hochberg FDR, Storey's q-value, SAM and resampling based FDR procedures. False Non-discovery Rates and estimates of the number of null hypotheses are computed from those methods and compared. Our simulation study shows that methods such as SAM and the q-value do not adequately control the FDR to the level claimed under dependence conditions. On the other hand, the adaptive Benjamini-Hochberg procedure seems to be most robust while remaining conservative. Finally, the estimates of the number of true null hypotheses under various dependence conditions are variable. Conclusion We discuss a new method for efficient guided simulation of dependent data, which satisfy imposed network constraints as conditional independence structures. Our simulation set-up allows for a structural study of the effect of dependencies on multiple testing criterions and is useful for testing a potentially new method on π0 or FDR estimation in a dependency context.

  15. Testing multiple coordination constraints with a novel bimanual visuomotor task.

    Directory of Open Access Journals (Sweden)

    Helene M Sisti

    Full Text Available The acquisition of a new bimanual skill depends on several motor coordination constraints. To date, coordination constraints have often been tested relatively independently of one another, particularly with respect to isofrequency and multifrequency rhythms. Here, we used a new paradigm to test the interaction of multiple coordination constraints. Coordination constraints that were tested included temporal complexity, directionality, muscle grouping, and hand dominance. Twenty-two healthy young adults performed a bimanual dial rotation task that required left and right hand coordination to track a moving target on a computer monitor. Two groups were compared, either with or without four days of practice with augmented visual feedback. Four directional patterns were tested such that both hands moved either rightward (clockwise, leftward (counterclockwise, inward or outward relative to each other. Seven frequency ratios (3∶1, 2∶1, 3∶2, 1∶1, 2∶3. 1∶2, 1∶3 between the left and right hand were introduced. As expected, isofrequency patterns (1∶1 were performed more successfully than multifrequency patterns (non 1∶1. In addition, performance was more accurate when participants were required to move faster with the dominant right hand (1∶3, 1∶2 and 2∶3 than with the non-dominant left hand (3∶1, 2∶1, 3∶2. Interestingly, performance deteriorated as the relative angular velocity between the two hands increased, regardless of whether the required frequency ratio was an integer or non-integer. This contrasted with previous finger tapping research where the integer ratios generally led to less error than the non-integer ratios. We suggest that this is due to the different movement topologies that are required of each paradigm. Overall, we found that this visuomotor task was useful for testing the interaction of multiple coordination constraints as well as the release from these constraints with practice in the presence of

  16. Assessment of patients with multiple sclerosis according to tests of the Multiple Sclerosis Functional Composite

    Directory of Open Access Journals (Sweden)

    Anelise Ineu Figueiredo

    Full Text Available Abstract Introduction: The Multiple Sclerosis Functional Composite (MSFC is a scale that evaluates the functional and cognitive aspects of patients with multiple sclerosis (MS. Objective: To compare the performance of individuals with the relapsing-remitting form of MS (RRMS with a group of healthy subjects using the MSFC. Methods: Twenty subjects were investigated in this study, consisting of 10 patients with clinical diagnosis of RRMS and 10 controls with similar gender and age to the group with the disease. The three tests that comprise the MSFC were used for the evaluation of gait, upper limb motor function and cognition (memory and processing speed. Student's t-test was used to assess data with normal distribution and data with skewed distribution were evaluated using the Mann-Whitney test. Results: The results showed that the patients with RRMS took longer to perform the locomotion test (6.91 ± 2.35 compared to the control group (5.16 ± 1.28. The MS group (22.06 ± 5.44 also showed greater difficulty in performing a task with the dominant upper limb compared to the healthy subjects (17.79 ± 2.96. No statistically significant difference was found between the groups in the performance of cognitive tasks (p = .65. Conclusion: The use of the MSFC tests proved valuable for measuring possible motor and cognitive impairments in patients with RRMS. Thus, it is suggested that this scale is adopted in clinical practice, improving therapies for the treatment of MS patients and thereby providing them a better quality of life.

  17. Tests for homogeneity for multiple 2 x 2 contingency tables

    International Nuclear Information System (INIS)

    Carr, D.B.

    1986-01-01

    Frequently data are described by 2 x 2 contingency tables. For example, each 2 x 2 table arises from two dichotomous classifications such as control/treated and respond/did not respond. Multiple 2 x 2 tables result from stratifying the observational units on the basis of other characteristics. For example, stratifying by sex produces separate 2 x 2 tables for males and females. From each table a measure of difference between the response rates for the control and the treated groups is computed. The researcher usually wants to know if the response-rate difference is zero for each table. If the tables are homogeneous, the researcher can generalize from a statement concerning an average to a statement concerning each table. If tables are not homogeneous, homogeneous subsets of the tables should be described separately. This paper presents tests for homogeneity and illustrates their use. 11 refs., 6 tabs

  18. Depression and pain: testing of serial multiple mediators.

    Science.gov (United States)

    Wongpakaran, Tinakon; Wongpakaran, Nahathai; Tanchakvaranont, Sitthinant; Bookkamana, Putipong; Pinyopornpanish, Manee; Wannarit, Kamonporn; Satthapisit, Sirina; Nakawiro, Daochompu; Hiranyatheb, Thanita; Thongpibul, Kulvadee

    2016-01-01

    Despite the fact that pain is related to depression, few studies have been conducted to investigate the variables that mediate between the two conditions. In this study, the authors explored the following mediators: cognitive function, self-sacrificing interpersonal problems, and perception of stress, and the effects they had on pain symptoms among patients with depressive disorders. An analysis was performed on the data of 346 participants with unipolar depressive disorders. The 17-item Hamilton Depression Rating Scale, Mini-Mental State Examination, the pain subscale of the health-related quality of life (SF-36), the self-sacrificing subscale of the Inventory of Interpersonal Problems, and the Perceived Stress Scale were used. Parallel multiple mediator and serial multiple mediator models were used. An alternative model regarding the effect of self-sacrificing on pain was also proposed. Perceived stress, self-sacrificing interpersonal style, and cognitive function were found to significantly mediate the relationship between depression and pain, while controlling for demographic variables. The total effect of depression on pain was significant. This model, with an additional three mediators, accounted for 15% of the explained variance in pain compared to 9% without mediators. For the alternative model, after controlling for the mediators, a nonsignificant total direct effect level of self-sacrificing was found, suggesting that the effect of self-sacrificing on pain was based only on an indirect effect and that perceived stress was found to be the strongest mediator. Serial mediation may help us to see how depression and pain are linked and what the fundamental mediators are in the chain. No significant, indirect effect of self-sacrificing on pain was observed, if perceived stress was not part of the depression and/or cognitive function mediational chain. The results shown here have implications for future research, both in terms of testing the model and in

  19. Bayesian models based on test statistics for multiple hypothesis testing problems.

    Science.gov (United States)

    Ji, Yuan; Lu, Yiling; Mills, Gordon B

    2008-04-01

    We propose a Bayesian method for the problem of multiple hypothesis testing that is routinely encountered in bioinformatics research, such as the differential gene expression analysis. Our algorithm is based on modeling the distributions of test statistics under both null and alternative hypotheses. We substantially reduce the complexity of the process of defining posterior model probabilities by modeling the test statistics directly instead of modeling the full data. Computationally, we apply a Bayesian FDR approach to control the number of rejections of null hypotheses. To check if our model assumptions for the test statistics are valid for various bioinformatics experiments, we also propose a simple graphical model-assessment tool. Using extensive simulations, we demonstrate the performance of our models and the utility of the model-assessment tool. In the end, we apply the proposed methodology to an siRNA screening and a gene expression experiment.

  20. Depression and pain: testing of serial multiple mediators

    Directory of Open Access Journals (Sweden)

    Wongpakaran T

    2016-07-01

    function were found to significantly mediate the relationship between depression and pain, while controlling for demographic variables. The total effect of depression on pain was significant. This model, with an additional three mediators, accounted for 15% of the explained variance in pain compared to 9% without mediators. For the alternative model, after controlling for the mediators, a nonsignificant total direct effect level of self-sacrificing was found, suggesting that the effect of self-sacrificing on pain was based only on an indirect effect and that perceived stress was found to be the strongest mediator.Conclusion: Serial mediation may help us to see how depression and pain are linked and what the fundamental mediators are in the chain. No significant, indirect effect of self-sacrificing on pain was observed, if perceived stress was not part of the depression and/or cognitive function mediational chain. The results shown here have implications for future research, both in terms of testing the model and in clinical application. Keywords: depressive disorder, mediator, serial mediation, multiple mediation

  1. A multiple objective test assembly approach for exposure control problems in Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    Theo J.H.M. Eggen

    2010-01-01

    Full Text Available Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has to be maximized, item compromise has to be minimized, and pool usage has to be optimized. In this paper, a multiple objectives method is developed to deal with both types of exposure problems. In this method, exposure control parameters based on observed exposure rates are implemented as weights for the information in the item selection procedure. The method does not need time consuming simulation studies, and it can be implemented conditional on ability level. The method is compared with Sympson Hetter method for exposure control, with the Progressive method and with alphastratified testing. The results show that the method is successful in dealing with both kinds of exposure problems.

  2. Multiple Monte Carlo Testing with Applications in Spatial Point Processes

    DEFF Research Database (Denmark)

    Mrkvička, Tomáš; Myllymäki, Mari; Hahn, Ute

    with a function as the test statistic, 3) several Monte Carlo tests with functions as test statistics. The rank test has correct (global) type I error in each case and it is accompanied with a p-value and with a graphical interpretation which shows which subtest or which distances of the used test function......(s) lead to the rejection at the prescribed significance level of the test. Examples of null hypothesis from point process and random set statistics are used to demonstrate the strength of the rank envelope test. The examples include goodness-of-fit test with several test functions, goodness-of-fit test...

  3. IOT Based Inline Errands IBIE

    Directory of Open Access Journals (Sweden)

    Ramesh G

    2015-08-01

    Full Text Available The Internet of Things IoT is an emerging technology that is creating an enormous network of things communicating with one another. It involves a broad set of technologies hardware and software stacks. Data humans devices and communication are critical elements of an IoT ecosystem. The primary purpose of this research paper is to provide an advantageous application in day to day life in redeemable time factor. Now a days shopping at malls is a daily or weekly activity of domestic life. Survey states during the initial week of month and weekends are the peak sale periods at shopping malls and super markets. Often equivalent time is taken for billing and payment as time taken for shopping. The Application introduced in this paper provides smart solution to redeemable time.

  4. The Efficiency of Quantum Identity Testing of Multiple States

    OpenAIRE

    Kada, Masaru; Nishimura, Harumichi; Yamakami, Tomoyuki

    2008-01-01

    We examine two quantum operations, the Permutation Test and the Circle Test, which test the identity of n quantum states. These operations naturally extend the well-studied Swap Test on two quantum states. We first show the optimality of the Permutation Test for any input size n as well as the optimality of the Circle Test for three input states. In particular, when n=3, we present a semi-classical protocol, incorporated with the Swap Test, which approximates the Circle Test efficiently. Furt...

  5. Test of understanding of vectors: A reliable multiple-choice vector concept test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  6. Planned Hypothesis Tests Are Not Necessarily Exempt from Multiplicity Adjustment

    Science.gov (United States)

    Frane, Andrew V.

    2015-01-01

    Scientific research often involves testing more than one hypothesis at a time, which can inflate the probability that a Type I error (false discovery) will occur. To prevent this Type I error inflation, adjustments can be made to the testing procedure that compensate for the number of tests. Yet many researchers believe that such adjustments are…

  7. Competition in Multiple Characteristics: An Empirical Test of Location Equilibrium.

    OpenAIRE

    Elizalde, J. (Javier)

    2010-01-01

    With products differentiated in multiple dimensions, the location equilibrium for a duopolistic market exhibits aximum differentiation in one dimension and minimum differentiation in all the other dimensions. This paper analyses whether this equilibrium arises using real data for the Spanish movie theatre exhibition market where the firms (cinemas) are differentiated along two dimensions (their geographical location and the set of movies exhibited). Data not only shows a trade-off such that c...

  8. Statistical tests for equal predictive ability across multiple forecasting methods

    DEFF Research Database (Denmark)

    Borup, Daniel; Thyrsgaard, Martin

    We develop a multivariate generalization of the Giacomini-White tests for equal conditional predictive ability. The tests are applicable to a mixture of nested and non-nested models, incorporate estimation uncertainty explicitly, and allow for misspecification of the forecasting model as well as ...

  9. Testing subleading multiple soft graviton theorem for CHY prescription

    Science.gov (United States)

    Chakrabarti, Subhroneel; Kashyap, Sitender Pratap; Sahoo, Biswajit; Sen, Ashoke; Verma, Mritunjay

    2018-01-01

    In arXiv:1707.06803 we derived the subleading multiple soft graviton theorem in a generic quantum theory of gravity for arbitrary number of soft external gravitons and arbitrary number of finite energy external states carrying arbitrary mass and spin. In this paper we verify this explicitly using the CHY formula for tree level scattering amplitudes of arbitrary number of gravitons in Einstein gravity. We pay special care to fix the signs of the amplitudes and resolve an apparent discrepancy between our general results in arXiv:1707.06803 and previous results on soft graviton theorem from CHY formula.

  10. A Powerful Test for Comparing Multiple Regression Functions.

    Science.gov (United States)

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  11. Multiple HEPA filter test methods, January--December 1976

    International Nuclear Information System (INIS)

    Schuster, B.; Kyle, T.; Osetek, D.

    1977-06-01

    The testing of tandem high-efficiency particulate air (HEPA) filter systems is of prime importance for the measurement of accurate overall system protection factors. A procedure, based on the use of an intra-cavity laser particle spectrometer, has been developed for measuring protection factors in the 10 8 range. A laboratory scale model of a filter system was constructed and initially tested to determine individual HEPA filter characteristics with regard to size and state (liquid or solid) of several test aerosols. Based on these laboratory measurements, in-situ testing has been successfully conducted on a number of single and tandem filter installations within the Los Alamos Scientific Laboratory as well as on extraordinary large single systems at Rocky Flats. For the purpose of recovery and for simplified solid waste disposal, or prefiltering purposes, two versions of an inhomogeneous electric field air cleaner have been devised and are undergoing testing. Initial experience with one of the systems, which relies on an electrostatic spraying phenomenon, indicates performance efficiency of greater than 99.9% for flow velocities commonly used in air cleaning systems. Among the effluents associated with nuclear fuel reprocessing is 129 I. An intra-cavity laser detection system is under development which shows promise of being able to detect mixing ratios of one part in 10 7 , I 2 in air

  12. Inherent variation in multiple shoe-sole test impressions.

    Science.gov (United States)

    Shor, Yaron; Wiesner, Sarena; Tsach, Tsadok; Gurel, Ron; Yekutieli, Yoram

    2018-04-01

    Shoeprints left at crime scenes are seldom perfect. Many prints are distorted or contaminated by various materials. Noisy background often contributes to vagueness on the shoeprints as well. Test impressions made from the suspect's shoes in the laboratory are considered a genuine replication of the shoe-sole. This naïve attitude is far from being correct. Consecutive test impressions made in the laboratory under strict similar conditions revealed differences among the exemplars of the same sole. Some of them are minor, but some are major, and can mislead the less experienced practitioners during the comparison process. This article focuses on the inherent within source variability between controlled shoeprints made from the same shoe, as it appears on the RACs. To describe and analyze this variability, repeated test impressions were prepared, and datasets were created. Several RACs were marked on each test impression, using an expert assisting software tool (developed in the authors' lab). The variance in repeated test impressions is demonstrated and possible sources are discussed. This variance should be considered when trying to establish the degree of matching between individual characteristics. Copyright © 2017. Published by Elsevier B.V.

  13. Strategic alternatives ranking methodology: Multiple RCRA incinerator evaluation test case

    International Nuclear Information System (INIS)

    Baker, G.; Thomson, R.D.; Reece, J.; Springer, L.; Main, D.

    1988-01-01

    This paper presents an important process approach to permit quantification and ranking of multiple alternatives being considered in remedial actions or hazardous waste strategies. This process is a methodology for evaluating programmatic options in support of site selection or environmental analyses. Political or other less tangible motivations for alternatives may be quantified by means of establishing the range of significant variables, weighting their importance, and by establishing specific criteria for scoring individual alternatives. An application of the process to a recent AFLC program permitted ranking incineration alternatives from a list of over 130 options. The process forced participation by the organizations to be effected, allowed a consensus of opinion to be achieved, allowed complete flexibility to evaluate factor sensitivity, and resulted in strong, quantifiable support for any subsequent site-selection action NEPA documents

  14. Multiple (Two) Met Bel 601 In Series Ultimate Vacuum Testing

    Energy Technology Data Exchange (ETDEWEB)

    Restivo, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-30

    SRNL Environmental and Chemical Process Technology (E&CPT) was requested to perform testing of vacuum pumps per a verbal request from the Customer, SRNL Hydrogen Processing Technology. Tritium Operations is currently having difficulties procuring the Normetex™® Model 15 m3/hr (9 CFM) vacuum pump (formerly Normetex Pompes, now EumecaSARL). One possible solution proposed by Hydrogen Processing Technology personnel is to use two Senior Aerospace Metal Bellows MB-601 vacuum pumps piped with the heads in series, and the pumps in series (Figure 1 below). This memorandum documents the ultimate vacuum testing that was performed to determine if this concept was a viable alternate vacuum pump strategy. This testing dovetails with previous pump evaluations documented in references 1 and 2.

  15. Feedback enhances the positive effects and reduces the negative effects of multiple-choice testing.

    Science.gov (United States)

    Butler, Andrew C; Roediger, Henry L

    2008-04-01

    Multiple-choice tests are used frequently in higher education without much consideration of the impact this form of assessment has on learning. Multiple-choice testing enhances retention of the material tested (the testing effect); however, unlike other tests, multiple-choice can also be detrimental because it exposes students to misinformation in the form of lures. The selection of lures can lead students to acquire false knowledge (Roediger & Marsh, 2005). The present research investigated whether feedback could be used to boost the positive effects and reduce the negative effects of multiple-choice testing. Subjects studied passages and then received a multiple-choice test with immediate feedback, delayed feedback, or no feedback. In comparison with the no-feedback condition, both immediate and delayed feedback increased the proportion of correct responses and reduced the proportion of intrusions (i.e., lure responses from the initial multiple-choice test) on a delayed cued recall test. Educators should provide feedback when using multiple-choice tests.

  16. Multiple sclerosis: Left advantage for auditory laterality in dichotic tests of central auditory processing and relationship of psychoacoustic tests with the Multiple Sclerosis Disability Scale-EDSS.

    Science.gov (United States)

    Peñaloza López, Yolanda Rebeca; Orozco Peña, Xóchitl Daisy; Pérez Ruiz, Santiago Jesús

    2018-04-03

    To evaluate the central auditory processing disorders in patients with multiple sclerosis, emphasizing auditory laterality by applying psychoacoustic tests and to identify their relationship with the Multiple Sclerosis Disability Scale (EDSS) functions. Depression scales (HADS), EDSS, and 9 psychoacoustic tests to study CAPD were applied to 26 individuals with multiple sclerosis and 26 controls. Correlation tests were performed between the EDSS and psychoacoustic tests. Seven out of 9 psychoacoustic tests were significantly different (P<.05); right or left (14/19 explorations) with respect to control. In dichotic digits there was a left-ear advantage compared to the usual predominance of RDD. There was significant correlation in five psychoacoustic tests and the specific functions of EDSS. The left-ear advantage detected and interpreted as an expression of deficient influences of the corpus callosum and attention in multiple sclerosis should be investigated. There was a correlation between psychoacoustic tests and specific EDSS functions. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Multiple Maximum Exposure Rates in Computerized Adaptive Testing

    Science.gov (United States)

    Ramon Barrada, Juan; Veldkamp, Bernard P.; Olea, Julio

    2009-01-01

    Computerized adaptive testing is subject to security problems, as the item bank content remains operative over long periods and administration time is flexible for examinees. Spreading the content of a part of the item bank could lead to an overestimation of the examinees' trait level. The most common way of reducing this risk is to impose a…

  18. Principal permeability determination from multiple horizontal well tests

    Energy Technology Data Exchange (ETDEWEB)

    Economides, M. [Texas A and M Univ., TX (United States); Munoz, A.; Ehlig-Economides, C.

    1998-12-31

    A method for obtaining principal permeability magnitudes and direction that requires only the linear flow regime from transient tests in three horizontal wells oriented in three distinct and arbitrary directions, is described. Well design optimization strategies require knowledge of both the principal permeability orientation as well as the horizontal permeability magnitudes. When the degree of horizontal permeability anisotropy (i.e. permeability in the bedding plane with respect to direction) is significant, the productivity of a long horizontal well will depend greatly on its direction, especially when the well is first brought into production. Productivities have been found to deviate substantially among wells in the same reservoir and this deviation has been attributed to differences in well orientation. In view of this fact, measuring permeability anisotropy becomes a compelling necessity. The success of the proposed method is illustrated by a case study in which the principal permeability magnitudes and direction from three wells were used to predict the productivity of a fourth well within 10 per cent. Use of the computed principal permeabilities from the case study, it was possible to forecast the cumulative production to show the significance of well trajectory optimization on the discounted cash flow and the net present value. 20 refs., 3 figs.

  19. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    Science.gov (United States)

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  20. Hydrologic test plans for large-scale, multiple-well tests in support of site characterization at Hanford, Washington

    International Nuclear Information System (INIS)

    Rogers, P.M.; Stone, R.; Lu, A.H.

    1985-01-01

    The Basalt Waste Isolation Project is preparing plans for tests and has begun work on some tests that will provide the data necessary for the hydrogeologic characterization of a site located on a United States government reservation at Hanford, Washington. This site is being considered for the Nation's first geologic repository of high level nuclear waste. Hydrogeologic characterization of this site requires several lines of investigation which include: surface-based small-scale tests, testing performed at depth from an exploratory shaft, geochemistry investigations, regional studies, and site-specific investigations using large-scale, multiple-well hydraulic tests. The large-scale multiple-well tests are planned for several locations in and around the site. These tests are being designed to provide estimates of hydraulic parameter values of the geologic media, chemical properties of the groundwater, and hydrogeologic boundary conditions at a scale appropriate for evaluating repository performance with respect to potential radionuclide transport

  1. On the Equivalence of Constructed-Response and Multiple-Choice Tests.

    Science.gov (United States)

    Traub, Ross E.; Fisher, Charles W.

    Two sets of mathematical reasoning and two sets of verbal comprehension items were cast into each of three formats--constructed response, standard multiple-choice, and Coombs multiple-choice--in order to assess whether tests with indentical content but different formats measure the same attribute, except for possible differences in error variance…

  2. Within-day variability on short and long walking tests in persons with multiple sclerosis

    NARCIS (Netherlands)

    Feys, P.; Bibby, B.; Romberg, A.; Santoyo, C.; Gebara, B.; de Noordhout, B.M.; Knuts, K.; Bethoux, F.; Skjerbaek, A.; Jensen, E.; Baert, I.; Vaney, C.; de Groot, V.; Dalgas, U.

    2014-01-01

    Objective To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Design Observational study. Setting MS rehabilitation and research centers in Europe and US within

  3. All of the above: When multiple correct response options enhance the testing effect.

    Science.gov (United States)

    Bishara, Anthony J; Lanzo, Lauren A

    2015-01-01

    Previous research has shown that multiple choice tests often improve memory retention. However, the presence of incorrect lures often attenuates this memory benefit. The current research examined the effects of "all of the above" (AOTA) options. When such options are correct, no incorrect lures are present. In the first three experiments, a correct AOTA option on an initial test led to a larger memory benefit than no test and standard multiple choice test conditions. The benefits of a correct AOTA option occurred even without feedback on the initial test; for both 5-minute and 48-hour retention delays; and for both cued recall and multiple choice final test formats. In the final experiment, an AOTA question led to better memory retention than did a control condition that had identical timing and exposure to response options. However, the benefits relative to this control condition were similar regardless of the type of multiple choice test (AOTA or not). Results suggest that retrieval contributes to multiple choice testing effects. However, the extra testing effect from a correct AOTA option, rather than being due to more retrieval, might be due simply to more exposure to correct information.

  4. Validity of multiple stress creep recovery test for LADOTD asphalt binder specification.

    Science.gov (United States)

    2010-09-01

    The objectives of this research are to characterize the elastic response of various binders used by LADOTD to determine the feasibility of the Multiple Stress Creep Recovery (MSCR) test to be included in the LADOTD asphalt binder specification and to...

  5. Using automatic item generation to create multiple-choice test items.

    Science.gov (United States)

    Gierl, Mark J; Lai, Hollis; Turner, Simon R

    2012-08-01

    Many tests of medical knowledge, from the undergraduate level to the level of certification and licensure, contain multiple-choice items. Although these are efficient in measuring examinees' knowledge and skills across diverse content areas, multiple-choice items are time-consuming and expensive to create. Changes in student assessment brought about by new forms of computer-based testing have created the demand for large numbers of multiple-choice items. Our current approaches to item development cannot meet this demand. We present a methodology for developing multiple-choice items based on automatic item generation (AIG) concepts and procedures. We describe a three-stage approach to AIG and we illustrate this approach by generating multiple-choice items for a medical licensure test in the content area of surgery. To generate multiple-choice items, our method requires a three-stage process. Firstly, a cognitive model is created by content specialists. Secondly, item models are developed using the content from the cognitive model. Thirdly, items are generated from the item models using computer software. Using this methodology, we generated 1248 multiple-choice items from one item model. Automatic item generation is a process that involves using models to generate items using computer technology. With our method, content specialists identify and structure the content for the test items, and computer technology systematically combines the content to generate new test items. By combining these outcomes, items can be generated automatically. © Blackwell Publishing Ltd 2012.

  6. A simplified approach for evaluating multiple test outcomes and multiple disease states in relation to the exercise thallium-201 stress test in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Pollock, S.G.; Watson, D.D.; Gibson, R.S.; Beller, G.A.; Kaul, S.

    1989-01-01

    This study describes a simplified approach for the interpretation of electrocardiographic and thallium-201 imaging data derived from the same patient during exercise. The 383 patients in this study had also undergone selective coronary arteriography within 3 months of the exercise test. This matrix approach allows for multiple test outcomes (both tests positive, both negative, 1 test positive and 1 negative) and multiple disease states (no coronary artery disease vs 1-vessel vs multivessel coronary artery disease). Because this approach analyzes the results of 2 test outcomes simultaneously rather than serially, it also negates the lack of test independence, if such an effect is present. It is also demonstrated that ST-segment depression on the electrocardiogram and defects on initial thallium-201 images provide conditionally independent information regarding the presence of coronary artery disease in patients without prior myocardial infarction. In contrast, ST-segment depression on the electrocardiogram and redistribution on the delayed thallium-201 images may not provide totally independent information regarding the presence of exercise-induced ischemia in patients with or without myocardial infarction

  7. The Symbol Digit Modalities Test as sentinel test for cognitive impairment in multiple sclerosis

    NARCIS (Netherlands)

    Van Schependom, J.; D'hooghe, M. B.; Cleynhens, K.; D'hooge, M.; Haelewyck, M. C.; De Keyser, J.; Nagels, G.

    Background and purpose: Cognitive impairment (CI) is found in about half of the multiple sclerosis (MS) population and is an important contributor to employment status and social functioning. CI is encountered in all disease stages and correlates only moderately with disease duration or Expanded

  8. From One to Multiple Accents on a Test of L2 Listening Comprehension

    Science.gov (United States)

    Ockey, Gary J.; French, Robert

    2016-01-01

    Concerns about the need for assessing multidialectal listening skills for global contexts are becoming increasingly prevalent. However, the inclusion of multiple accents on listening assessments may threaten test fairness because it is not practical to include every accent that may be encountered in the language use domain on these tests. Given…

  9. Multiple-Choice versus Constructed-Response Tests in the Assessment of Mathematics Computation Skills.

    Science.gov (United States)

    Gadalla, Tahany M.

    The equivalence of multiple-choice (MC) and constructed response (discrete) (CR-D) response formats as applied to mathematics computation at grade levels two to six was tested. The difference between total scores from the two response formats was tested for statistical significance, and the factor structure of items in both response formats was…

  10. A Particle Swarm Optimization Approach to Composing Serial Test Sheets for Multiple Assessment Criteria

    Science.gov (United States)

    Yin, Peng-Yeng; Chang, Kuang-Cheng; Hwang, Gwo-Jen; Hwang, Gwo-Haur; Chan, Ying

    2006-01-01

    To accurately analyze the problems of students in learning, the composed test sheets must meet multiple assessment criteria, such as the ratio of relevant concepts to be evaluated, the average discrimination degree, difficulty degree and estimated testing time. Furthermore, to precisely evaluate the improvement of student's learning performance…

  11. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  12. Multiple Sources of Test Bias on the WISC-R and Bender-Gestalt Test.

    Science.gov (United States)

    Oakland, Thomas; Feigenbaum, David

    1979-01-01

    Assessed test bias on the Wechsler Intelligence Test for Children-Revised (WISC-R) and Bender-Gestalt. On the Bender, evidence of bias was infrequent and irregular. On the WISC-R, group differences were most discernible for age, sex, family structure, and race. Consistent patterns of bias were not apparent among comparison groups. (Author)

  13. Impact of Answer-Switching Behavior on Multiple-Choice Test Scores in Higher Education

    Directory of Open Access Journals (Sweden)

    Ramazan BAŞTÜRK

    2011-06-01

    Full Text Available The multiple- choice format is one of the most popular selected-response item formats used in educational testing. Researchers have shown that Multiple-choice type test is a useful vehicle for student assessment in core university subjects that usually have large student numbers. Even though the educators, test experts and different test recourses maintain the idea that the first answer should be retained, many researchers argued that this argument is not dependent with empirical findings. The main question of this study is to examine how the answer switching behavior affects the multiple-choice test score. Additionally, gender differences and relationship between number of answer switching behavior and item parameters (item difficulty and item discrimination were investigated. The participants in this study consisted of 207 upper-level College of Education students from mid-sized universities. A Midterm exam consisted of 20 multiple-choice questions was used. According to the result of this study, answer switching behavior statistically increase test scores. On the other hand, there is no significant gender difference in answer-switching behavior. Additionally, there is a significant negative relationship between answer switching behavior and item difficulties.

  14. A P-value model for theoretical power analysis and its applications in multiple testing procedures

    Directory of Open Access Journals (Sweden)

    Fengqing Zhang

    2016-10-01

    Full Text Available Abstract Background Power analysis is a critical aspect of the design of experiments to detect an effect of a given size. When multiple hypotheses are tested simultaneously, multiplicity adjustments to p-values should be taken into account in power analysis. There are a limited number of studies on power analysis in multiple testing procedures. For some methods, the theoretical analysis is difficult and extensive numerical simulations are often needed, while other methods oversimplify the information under the alternative hypothesis. To this end, this paper aims to develop a new statistical model for power analysis in multiple testing procedures. Methods We propose a step-function-based p-value model under the alternative hypothesis, which is simple enough to perform power analysis without simulations, but not too simple to lose the information from the alternative hypothesis. The first step is to transform distributions of different test statistics (e.g., t, chi-square or F to distributions of corresponding p-values. We then use a step function to approximate each of the p-value’s distributions by matching the mean and variance. Lastly, the step-function-based p-value model can be used for theoretical power analysis. Results The proposed model is applied to problems in multiple testing procedures. We first show how the most powerful critical constants can be chosen using the step-function-based p-value model. Our model is then applied to the field of multiple testing procedures to explain the assumption of monotonicity of the critical constants. Lastly, we apply our model to a behavioral weight loss and maintenance study to select the optimal critical constants. Conclusions The proposed model is easy to implement and preserves the information from the alternative hypothesis.

  15. Testing a multiple mediation model of Asian American college students' willingness to see a counselor.

    Science.gov (United States)

    Kim, Paul Youngbin; Park, Irene J K

    2009-07-01

    Adapting the theory of reasoned action, the present study examined help-seeking beliefs, attitudes, and intent among Asian American college students (N = 110). A multiple mediation model was tested to see if the relation between Asian values and willingness to see a counselor was mediated by attitudes toward seeking professional psychological help and subjective norm. A bootstrapping procedure was used to test the multiple mediation model. Results indicated that subjective norm was the sole significant mediator of the effect of Asian values on willingness to see a counselor. The findings highlight the importance of social influences on help-seeking intent among Asian American college students.

  16. Test of Understanding of Vectors: A Reliable Multiple-Choice Vector Concept Test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-01-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended…

  17. Stochastic order in dichotomous item response models for fixed tests, research adaptive tests, or multiple abilities

    NARCIS (Netherlands)

    van der Linden, Willem J.

    1995-01-01

    Dichotomous item response theory (IRT) models can be viewed as families of stochastically ordered distributions of responses to test items. This paper explores several properties of such distributiom. The focus is on the conditions under which stochastic order in families of conditional

  18. The "None of the Above" Option in Multiple-Choice Testing: An Experimental Study

    Science.gov (United States)

    DiBattista, David; Sinnige-Egger, Jo-Anne; Fortuna, Glenda

    2014-01-01

    The authors assessed the effects of using "none of the above" as an option in a 40-item, general-knowledge multiple-choice test administered to undergraduate students. Examinees who selected "none of the above" were given an incentive to write the correct answer to the question posed. Using "none of the above" as the…

  19. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs in...

  20. Performance on Paced Auditory Serial Addition Test and cerebral blood flow in multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, M.; Steen, C.; Hoogduin, J. M.; van Osch, M. J. P.; Fierens, Y.; Cambron, M.; Koch, M. W.; De Keyser, J.

    BackgroundTo assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). MethodsNormal

  1. Application of range-test in multiple linear regression analysis in ...

    African Journals Online (AJOL)

    Application of range-test in multiple linear regression analysis in the presence of outliers is studied in this paper. First, the plot of the explanatory variables (i.e. Administration, Social/Commercial, Economic services and Transfer) on the dependent variable (i.e. GDP) was done to identify the statistical trend over the years.

  2. Constructing a multiple choice test to measure elementary school teachers' Pedagogical Content Knowledge of technology education.

    NARCIS (Netherlands)

    Rohaan, E.J.; Taconis, R.; Jochems, W.M.G.

    2009-01-01

    This paper describes the construction and validation of a multiple choice test to measure elementary school teachers' Pedagogical Content Knowledge of technology education. Pedagogical Content Knowledge is generally accepted to be a crucial domain of teacher knowledge and is, therefore, an important

  3. Testing Mediation Using Multiple Regression and Structural Equation Modeling Analyses in Secondary Data

    Science.gov (United States)

    Li, Spencer D.

    2011-01-01

    Mediation analysis in child and adolescent development research is possible using large secondary data sets. This article provides an overview of two statistical methods commonly used to test mediated effects in secondary analysis: multiple regression and structural equation modeling (SEM). Two empirical studies are presented to illustrate the…

  4. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs...

  5. Multiple linear combination (MLC) regression tests for common variants adapted to linkage disequilibrium structure.

    Science.gov (United States)

    Yoo, Yun Joo; Sun, Lei; Poirier, Julia G; Paterson, Andrew D; Bull, Shelley B

    2017-02-01

    By jointly analyzing multiple variants within a gene, instead of one at a time, gene-based multiple regression can improve power, robustness, and interpretation in genetic association analysis. We investigate multiple linear combination (MLC) test statistics for analysis of common variants under realistic trait models with linkage disequilibrium (LD) based on HapMap Asian haplotypes. MLC is a directional test that exploits LD structure in a gene to construct clusters of closely correlated variants recoded such that the majority of pairwise correlations are positive. It combines variant effects within the same cluster linearly, and aggregates cluster-specific effects in a quadratic sum of squares and cross-products, producing a test statistic with reduced degrees of freedom (df) equal to the number of clusters. By simulation studies of 1000 genes from across the genome, we demonstrate that MLC is a well-powered and robust choice among existing methods across a broad range of gene structures. Compared to minimum P-value, variance-component, and principal-component methods, the mean power of MLC is never much lower than that of other methods, and can be higher, particularly with multiple causal variants. Moreover, the variation in gene-specific MLC test size and power across 1000 genes is less than that of other methods, suggesting it is a complementary approach for discovery in genome-wide analysis. The cluster construction of the MLC test statistics helps reveal within-gene LD structure, allowing interpretation of clustered variants as haplotypic effects, while multiple regression helps to distinguish direct and indirect associations. © 2016 The Authors Genetic Epidemiology Published by Wiley Periodicals, Inc.

  6. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    Science.gov (United States)

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  7. PCA-based bootstrap confidence interval tests for gene-disease association involving multiple SNPs

    Directory of Open Access Journals (Sweden)

    Xue Fuzhong

    2010-01-01

    Full Text Available Abstract Background Genetic association study is currently the primary vehicle for identification and characterization of disease-predisposing variant(s which usually involves multiple single-nucleotide polymorphisms (SNPs available. However, SNP-wise association tests raise concerns over multiple testing. Haplotype-based methods have the advantage of being able to account for correlations between neighbouring SNPs, yet assuming Hardy-Weinberg equilibrium (HWE and potentially large number degrees of freedom can harm its statistical power and robustness. Approaches based on principal component analysis (PCA are preferable in this regard but their performance varies with methods of extracting principal components (PCs. Results PCA-based bootstrap confidence interval test (PCA-BCIT, which directly uses the PC scores to assess gene-disease association, was developed and evaluated for three ways of extracting PCs, i.e., cases only(CAES, controls only(COES and cases and controls combined(CES. Extraction of PCs with COES is preferred to that with CAES and CES. Performance of the test was examined via simulations as well as analyses on data of rheumatoid arthritis and heroin addiction, which maintains nominal level under null hypothesis and showed comparable performance with permutation test. Conclusions PCA-BCIT is a valid and powerful method for assessing gene-disease association involving multiple SNPs.

  8. Design and performance of beam test electronics for the PHENIX multiplicity vertex detector

    International Nuclear Information System (INIS)

    Britton, C.L. Jr.; Bryan, W.L.; Emery, M.S.

    1996-01-01

    The system architecture and test results of the custom circuits and beam test system for the Multiplicity-Vertex Detector (MVD) for the PHENIX detector collaboration at the Relativistic Heavy Ion Collider (RHIC) are presented in this paper. The final detector per-channel signal processing chain will consist of a preamplifier-gain stage, a current-mode summed multiplicity discriminator, a 64-deep analog memory (simultaneous read-write), a post-memory analog correlator, and a 10-bit 5 μs ADC. The Heap Manager provides all timing control, data buffering, and data formatting for a single 256-channel multi-chip module (MCM). Each chip set is partitioned into 32-channel sets. Beam test (16-cell deep memory) performance for the various blocks will be presented as well as the ionizing radiation damage performance of the 1.2 μ n-well CMOS process used for preamplifier fabrication

  9. Analysis of Multiple Choice Tests Designed by Faculty Members of Kermanshah University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    Reza Pourmirza Kalhori

    2013-12-01

    Full Text Available Dear Editor Multiple choice tests are the most common objective tests in medical education which are used to assess the ind-ividual knowledge, recall, recognition and problem solving abilities. One of the testing components is the post-test analysis. This component includes; first, qualitative analysis of the taxonomy of questions based on the Bloom’s educational objectives and percentage of the questions with no structural problems; and second, the quantitative analysis of the reliability (KR-20 and indices of difficulty and differentiation (1. This descriptive-analytical study was aimed to qualitatively and quan-titatively investigate the multiple-choice tests of the faculty members at Kermanshah University of Medical Sciences in 2009-2010. The sample size comprised of 156 tests. Data were analyzed by SPSS-16 software using t-test, chi-squared test, ANOVA and Tukey multiple comparison tests. The mean of reliability (KR-20, difficulty index, and discrimination index were 0.68 (± 0.31, 0.56 (± 0.15 and 0.21 (± 0.15, respectively, which were acceptable. The analysis of the tests at Mashad University of Medical Sciences indicated that the mean for the reliability of the tests was 0.72, and 52.2% of the tests had inappropriate difficulty index and 49.2% of the tests did not have acceptable differentiation index (2. Comparison of the tests at Kermanshah University of Medical Sciences for the fields of anatomy, physiology, biochemistry, genetics, statistics and behavioral sciences courses at Malaysia Faculty of Medicine (3 and tests at Argentina Faculty of Medicine (4 showed that while difficulty index was acceptable in all three universities, but differentiation indices in Malaysia and Argentina Medical Faculties were higher than that in Kermanshah University of Medical Sciences. The mean for the questions with no structural flaws in all tests, taxonomy I, taxonomy II, and taxonomy III were 73.88% (± 14.88, 34.65% (± 15.78, 41.34% (± 13

  10. A permutation-based multiple testing method for time-course microarray experiments

    Directory of Open Access Journals (Sweden)

    George Stephen L

    2009-10-01

    Full Text Available Abstract Background Time-course microarray experiments are widely used to study the temporal profiles of gene expression. Storey et al. (2005 developed a method for analyzing time-course microarray studies that can be applied to discovering genes whose expression trajectories change over time within a single biological group, or those that follow different time trajectories among multiple groups. They estimated the expression trajectories of each gene using natural cubic splines under the null (no time-course and alternative (time-course hypotheses, and used a goodness of fit test statistic to quantify the discrepancy. The null distribution of the statistic was approximated through a bootstrap method. Gene expression levels in microarray data are often complicatedly correlated. An accurate type I error control adjusting for multiple testing requires the joint null distribution of test statistics for a large number of genes. For this purpose, permutation methods have been widely used because of computational ease and their intuitive interpretation. Results In this paper, we propose a permutation-based multiple testing procedure based on the test statistic used by Storey et al. (2005. We also propose an efficient computation algorithm. Extensive simulations are conducted to investigate the performance of the permutation-based multiple testing procedure. The application of the proposed method is illustrated using the Caenorhabditis elegans dauer developmental data. Conclusion Our method is computationally efficient and applicable for identifying genes whose expression levels are time-dependent in a single biological group and for identifying the genes for which the time-profile depends on the group in a multi-group setting.

  11. Developing the multiple stress-strain creep recovery (MS-SCR) test

    Science.gov (United States)

    Elnasri, Mahmoud; Airey, Gordon; Thom, Nick

    2018-04-01

    While most published work from Europe has been concerned with evaluating binders' resistance to rutting based on their stiffness (deformation resistance), work originating in the US has mainly been concerned with ranking binders based on their recoverability in a multiple stress form. This paper details the design of a new modified multiple stress-strain creep recovery (MS-SCR) test. The test is designed to evaluate binders' rutting resistance based on two rutting resistance mechanisms: stiffness and recoverability. A preliminary investigation is presented in this paper followed by details of the design of the new modified test. A 40/60 penetration grade bitumen and bitumen-filler mastics prepared with three filler concentrations (35%, 50%, and 65% filler content by mass of mastic) were tested. In addition, two polymer modified bitumens (PMBs) using the same base bitumen type were examined for validation. Two parameters are introduced to characterise the short and long recovery in the new test. In terms of stiffness, the test allows the behaviour of binders at different stress levels and loading cycles to be studied and produces a new parameter that can quantify the degree of modification. Finally, a relationship between nonlinearity and normal force in the test was investigated.

  12. Learners Test Performance and Gardner`s Multiple Inteligence Theory: Intercorrelation in a Bilingual Context

    Directory of Open Access Journals (Sweden)

    Bagher Azarmi

    2015-03-01

    Full Text Available Although decisions and inferences made based on test scores depend both on the characteristics of test takers and testing environment, the former seems to have the most overridingimportance. The present study which was conducted in a bilingual environment is in line with this assumption and is aimed at investigating intelligence as one of the test taker characteristics. First, it aimed at finding the possible correlation between any of the eight types of intelligences in Gardner`s MI theory and EAP test performance. Second, it intended to survey the intercorrelationamong the eight types of intelligences themselves. To that end, 122 male bilingual EFL learners who were all sophomore university students were chosen as the participants of the study. They satfor the final EAP exam and filled the questionnaire on multiple intelligence. The test takers' scores on EAP exam were correlated with their multiple intelligences. The result did not demonstrate anystatistically significant go-togetherness between EAP test performance and any types of intelligence; however, a significantly positive correlation was observed among the eight types of intelligences themselves showing that all types of intelligences are equally important and ought to be equally dealt with in EFL context.

  13. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    Science.gov (United States)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  14. Robust inference from multiple test statistics via permutations: a better alternative to the single test statistic approach for randomized trials.

    Science.gov (United States)

    Ganju, Jitendra; Yu, Xinxin; Ma, Guoguang Julie

    2013-01-01

    Formal inference in randomized clinical trials is based on controlling the type I error rate associated with a single pre-specified statistic. The deficiency of using just one method of analysis is that it depends on assumptions that may not be met. For robust inference, we propose pre-specifying multiple test statistics and relying on the minimum p-value for testing the null hypothesis of no treatment effect. The null hypothesis associated with the various test statistics is that the treatment groups are indistinguishable. The critical value for hypothesis testing comes from permutation distributions. Rejection of the null hypothesis when the smallest p-value is less than the critical value controls the type I error rate at its designated value. Even if one of the candidate test statistics has low power, the adverse effect on the power of the minimum p-value statistic is not much. Its use is illustrated with examples. We conclude that it is better to rely on the minimum p-value rather than a single statistic particularly when that single statistic is the logrank test, because of the cost and complexity of many survival trials. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Do Students Behave Rationally in Multiple Choice Tests? Evidence from a Field Experiment

    OpenAIRE

    María Paz Espinosa; Javier Gardeazabal

    2013-01-01

    A disadvantage of multiple choice tests is that students have incentives to guess. To discourage guessing, it is common to use scoring rules that either penalize wrong answers or reward omissions. In psychometrics, penalty and reward scoring rules are considered equivalent. However, experimental evidence indicates that students behave differently under penalty or reward scoring rules. These differences have been attributed to the different framing (penalty versus reward). In this paper, we mo...

  16. Relationship between contrast sensitivity test and disease severity in multiple sclerosis patients.

    Science.gov (United States)

    Soler García, A; González Gómez, A; Figueroa-Ortiz, L C; García-Ben, A; García-Campos, J

    2014-09-01

    To assess the importance of the Pelli-Robson contrast sensitivity test in multiple sclerosis patients according to the Expanded Disability Status Scale (EDSS). A total of 62 patients with multiple sclerosis were included in a retrospective study. Patients were enrolled from the Neurology Department to Neuroophthalmology at Virgen de la Victoria Hospital. Patients were classified into 3 groups according to EDSS: group A) lower than 1.5, group B) between 1.5 and 3.5 and group C) greater than 3.5. Visual acuity and monocular and binocular contrast sensitivity were performed with Snellen and Pelli-Robson tests respectively. Twelve disease-free control participants were also recruited. Correlations between parameter changes were analyzed. The mean duration of the disease was 81.54±35.32 months. Monocular and binocular Pelli-Robson mean values in the control group were 1.82±0.10 and 1.93±0.43 respectively, and 1.61±0.29 and 1.83±0.19 in multiple sclerosis patients. There were statistically significant differences in the monocular analysis for a level of significance P<.05. Mean monocular and binocular Pelli-Robson values in relation to gravity level were, in group A: 1.66±0.24 and 1.90±0.98, group B: 1.64±0.21 and 1.82±0.16, and group C: 1.47±0.45 and 1.73±0.32 respectively. Group differences were statistically significant in both tests: P=.05 and P=.027. Monocular and binocular contrast discrimination analyzed using the Pelli-Robson test was found to be significantly lower when the severity level, according EDSS, increases in multiple sclerosis patients. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  17. Development and tests of MCP based timing and multiplicity detector for MIPs

    Science.gov (United States)

    Feofilov, G.; Kondratev, V.; Stolyarov, O.; Tulina, T.; Valiev, F.; Vinogradov, L.

    2017-01-01

    We present summary of technological developments and tests of the MCP based large area detector aimed at precise timing and charged particles multiplicity measurements. Results obtained in course of these developments of isochronous (simultaneity) precise signal readout, passive summation of 1 ns signals, fast (1 GHz) front-end electronics, miniature vacuum systems, etc. could be potentially interesting for a number of future applications in different fields.

  18. Multiple testing corrections in quantitative proteomics: A useful but blunt tool.

    Science.gov (United States)

    Pascovici, Dana; Handler, David C L; Wu, Jemma X; Haynes, Paul A

    2016-09-01

    Multiple testing corrections are a useful tool for restricting the FDR, but can be blunt in the context of low power, as we demonstrate by a series of simple simulations. Unfortunately, in proteomics experiments low power can be common, driven by proteomics-specific issues like small effects due to ratio compression, and few replicates due to reagent high cost, instrument time availability and other issues; in such situations, most multiple testing corrections methods, if used with conventional thresholds, will fail to detect any true positives even when many exist. In this low power, medium scale situation, other methods such as effect size considerations or peptide-level calculations may be a more effective option, even if they do not offer the same theoretical guarantee of a low FDR. Thus, we aim to highlight in this article that proteomics presents some specific challenges to the standard multiple testing corrections methods, which should be employed as a useful tool but not be regarded as a required rubber stamp. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Testing multiple statistical hypotheses resulted in spurious associations: a study of astrological signs and health.

    Science.gov (United States)

    Austin, Peter C; Mamdani, Muhammad M; Juurlink, David N; Hux, Janet E

    2006-09-01

    To illustrate how multiple hypotheses testing can produce associations with no clinical plausibility. We conducted a study of all 10,674,945 residents of Ontario aged between 18 and 100 years in 2000. Residents were randomly assigned to equally sized derivation and validation cohorts and classified according to their astrological sign. Using the derivation cohort, we searched through 223 of the most common diagnoses for hospitalization until we identified two for which subjects born under one astrological sign had a significantly higher probability of hospitalization compared to subjects born under the remaining signs combined (P<0.05). We tested these 24 associations in the independent validation cohort. Residents born under Leo had a higher probability of gastrointestinal hemorrhage (P=0.0447), while Sagittarians had a higher probability of humerus fracture (P=0.0123) compared to all other signs combined. After adjusting the significance level to account for multiple comparisons, none of the identified associations remained significant in either the derivation or validation cohort. Our analyses illustrate how the testing of multiple, non-prespecified hypotheses increases the likelihood of detecting implausible associations. Our findings have important implications for the analysis and interpretation of clinical studies.

  20. Experiences in simulating and testing coordinated voltage control provided by multiple wind power plants

    Energy Technology Data Exchange (ETDEWEB)

    Arlaban, T.; Alonso, O.; Ortiz, D. [Acciona Windpower S.A. (Spain); Peiro, J.; Rivas, R. [Red Electrica de Espana SAU (Spain); Quinonez-Varela, G.; Lorenzo, P. [Acciona Energia S.A. (Spain)

    2011-07-01

    This document presents some field tests performed in a transmission system node in order to check the adequacy of voltage control performance by multiple wind power plants, with an overall capacity of 395 MW. It briefly explains the Spanish TSO motivation towards new voltage control requirements and the necessity of performing such tests in order to set the most convenient voltage control parameters and to verify the stable operation. It presents how different the voltage control capability between modern wind turbines (DFIG) and older ones (SCIG) specifically retrofitted for voltage control is. (orig.)

  1. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  2. General solutions to multiple testing problems. Translation of "Sonnemann, E. (1982). Allgemeine Lösungen multipler Test probleme. EDV in Medizin und Biologie 13(4), 120-128".

    Science.gov (United States)

    Sonnemann, Eckart

    2008-10-01

    The introduction of sequentially rejective multiple test procedures (Einot and Gabriel, 1975; Naik, 1975; Holm, 1977; Holm, 1979) has caused considerable progress in the theory of multiple comparisons. Emphasizing the closure of multiple tests we give a survey of the general theory and its recent results in applications. Some new applications are given including a discussion of the connection with the theory of confidence regions.

  3. The effects of multiple features of alternatively spliced exons on the KA/KS ratio test

    Directory of Open Access Journals (Sweden)

    Chen Feng-Chi

    2006-05-01

    Full Text Available Abstract Background The evolution of alternatively spliced exons (ASEs is of primary interest because these exons are suggested to be a major source of functional diversity of proteins. Many exon features have been suggested to affect the evolution of ASEs. However, previous studies have relied on the KA/KS ratio test without taking into consideration information sufficiency (i.e., exon length > 75 bp, cross-species divergence > 5% of the studied exons, leading to potentially biased interpretations. Furthermore, which exon feature dominates the results of the KA/KS ratio test and whether multiple exon features have additive effects have remained unexplored. Results In this study, we collect two different datasets for analysis – the ASE dataset (which includes lineage-specific ASEs and conserved ASEs and the ACE dataset (which includes only conserved ASEs. We first show that information sufficiency can significantly affect the interpretation of relationship between exons features and the KA/KS ratio test results. After discarding exons with insufficient information, we use a Boolean method to analyze the relationship between test results and four exon features (namely length, protein domain overlapping, inclusion level, and exonic splicing enhancer (ESE frequency for the ASE dataset. We demonstrate that length and protein domain overlapping are dominant factors, and they have similar impacts on test results of ASEs. In addition, despite the weak impacts of inclusion level and ESE motif frequency when considered individually, combination of these two factors still have minor additive effects on test results. However, the ACE dataset shows a slightly different result in that inclusion level has a marginally significant effect on test results. Lineage-specific ASEs may have contributed to the difference. Overall, in both ASEs and ACEs, protein domain overlapping is the most dominant exon feature while ESE frequency is the weakest one in affecting

  4. Semiparametric Allelic Tests for Mapping Multiple Phenotypes: Binomial Regression and Mahalanobis Distance.

    Science.gov (United States)

    Majumdar, Arunabha; Witte, John S; Ghosh, Saurabh

    2015-12-01

    Binary phenotypes commonly arise due to multiple underlying quantitative precursors and genetic variants may impact multiple traits in a pleiotropic manner. Hence, simultaneously analyzing such correlated traits may be more powerful than analyzing individual traits. Various genotype-level methods, e.g., MultiPhen (O'Reilly et al. []), have been developed to identify genetic factors underlying a multivariate phenotype. For univariate phenotypes, the usefulness and applicability of allele-level tests have been investigated. The test of allele frequency difference among cases and controls is commonly used for mapping case-control association. However, allelic methods for multivariate association mapping have not been studied much. In this article, we explore two allelic tests of multivariate association: one using a Binomial regression model based on inverted regression of genotype on phenotype (Binomial regression-based Association of Multivariate Phenotypes [BAMP]), and the other employing the Mahalanobis distance between two sample means of the multivariate phenotype vector for two alleles at a single-nucleotide polymorphism (Distance-based Association of Multivariate Phenotypes [DAMP]). These methods can incorporate both discrete and continuous phenotypes. Some theoretical properties for BAMP are studied. Using simulations, the power of the methods for detecting multivariate association is compared with the genotype-level test MultiPhen's. The allelic tests yield marginally higher power than MultiPhen for multivariate phenotypes. For one/two binary traits under recessive mode of inheritance, allelic tests are found to be substantially more powerful. All three tests are applied to two different real data and the results offer some support for the simulation study. We propose a hybrid approach for testing multivariate association that implements MultiPhen when Hardy-Weinberg Equilibrium (HWE) is violated and BAMP otherwise, because the allelic approaches assume HWE

  5. PERMANOVA-S: association test for microbial community composition that accommodates confounders and multiple distances.

    Science.gov (United States)

    Tang, Zheng-Zheng; Chen, Guanhua; Alekseyenko, Alexander V

    2016-09-01

    Recent advances in sequencing technology have made it possible to obtain high-throughput data on the composition of microbial communities and to study the effects of dysbiosis on the human host. Analysis of pairwise intersample distances quantifies the association between the microbiome diversity and covariates of interest (e.g. environmental factors, clinical outcomes, treatment groups). In the design of these analyses, multiple choices for distance metrics are available. Most distance-based methods, however, use a single distance and are underpowered if the distance is poorly chosen. In addition, distance-based tests cannot flexibly handle confounding variables, which can result in excessive false-positive findings. We derive presence-weighted UniFrac to complement the existing UniFrac distances for more powerful detection of the variation in species richness. We develop PERMANOVA-S, a new distance-based method that tests the association of microbiome composition with any covariates of interest. PERMANOVA-S improves the commonly-used Permutation Multivariate Analysis of Variance (PERMANOVA) test by allowing flexible confounder adjustments and ensembling multiple distances. We conducted extensive simulation studies to evaluate the performance of different distances under various patterns of association. Our simulation studies demonstrate that the power of the test relies on how well the selected distance captures the nature of the association. The PERMANOVA-S unified test combines multiple distances and achieves good power regardless of the patterns of the underlying association. We demonstrate the usefulness of our approach by reanalyzing several real microbiome datasets. miProfile software is freely available at https://medschool.vanderbilt.edu/tang-lab/software/miProfile z.tang@vanderbilt.edu or g.chen@vanderbilt.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  6. Agreement analysis comparing iPad LCVA and Sloan testing in multiple sclerosis patients.

    Science.gov (United States)

    Sattarnezhad, Neda; Farrow, Samantha; Kimbrough, Dorlan; Glanz, Bonnie; Healy, Brian; Chitnis, Tanuja

    2017-06-01

    Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting. To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients. A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test. For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p iPad-based LCVA test shows good agreement with Sloan testing in MS patients.

  7. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    Science.gov (United States)

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  8. Memory and other properties of multiple test procedures generated by entangled graphs.

    Science.gov (United States)

    Maurer, Willi; Bretz, Frank

    2013-05-10

    Methods for addressing multiplicity in clinical trials have attracted much attention during the past 20 years. They include the investigation of new classes of multiple test procedures, such as fixed sequence, fallback and gatekeeping procedures. More recently, sequentially rejective graphical test procedures have been introduced to construct and visualize complex multiple test strategies. These methods propagate the local significance level of a rejected null hypothesis to not-yet rejected hypotheses. In the graph defining the test procedure, hypotheses together with their local significance levels are represented by weighted vertices and the propagation rule by weighted directed edges. An algorithm provides the rules for updating the local significance levels and the transition weights after rejecting an individual hypothesis. These graphical procedures have no memory in the sense that the origin of the propagated significance level is ignored in subsequent iterations. However, in some clinical trial applications, memory is desirable to reflect the underlying dependence structure of the study objectives. In such cases, it would allow the further propagation of significance levels to be dependent on their origin and thus reflect the grouped parent-descendant structures of the hypotheses. We will give examples of such situations and show how to induce memory and other properties by convex combination of several individual graphs. The resulting entangled graphs provide an intuitive way to represent the underlying relative importance relationships between the hypotheses, are as easy to perform as the original individual graphs, remain sequentially rejective and control the familywise error rate in the strong sense. Copyright © 2012 John Wiley & Sons, Ltd.

  9. An alcohol withdrawal test battery measuring multiple behavioral symptoms in mice.

    Science.gov (United States)

    Metten, Pamela; Schlumbohm, Jason P; Huang, Lawrence C; Greenberg, Gian D; Hack, Wyatt R; Spence, Stephanie E; Crabbe, John C

    2018-05-01

    Despite acceptance that risk for alcohol-use disorder (AUD) has a large genetic component, the identification of genes underlying various components of risk for AUD has been hampered in humans, in part by the heterogeneity of expression of the phenotype. One aspect of AUD is physical dependence. Alcohol withdrawal is a serious consequence of alcohol dependence with multiple symptoms, many of which are seen in multiple species, and can be experienced over a wide-ranging time course. In the present three studies, we developed a battery of withdrawal tests in mice, examining behavioral symptoms from multiple domains that could be measured over time. To permit eventual use of the battery in different strains of mice, we used male and female mice of a genetically heterogeneous stock developed from intercrossing eight inbred strains. Withdrawal symptoms were assessed using commonly used tests after administration of ethanol in vapor for 72 continuous hours. We found significant effects of ethanol withdrawal versus air-breathing controls on nearly all symptoms, spanning 4 days following ethanol vapor inhalation. Withdrawal produced hypothermia, greater neurohyperexcitability (seizures and tremor), anxiety-like behaviors using an apparatus (such as reduced transitions between light and dark compartments), anhedonia (reduced sucrose preference), Straub tail, backward walking, and reductions in activity; however, there were no changes in thermal pain sensitivity, hyper-reactivity to handling, or anxiety-like emergence behaviors in other apparatus. Using these data, we constructed a refined battery of withdrawal tests. Individual differences in severity of withdrawal among different tests were weakly correlated at best. This battery should be useful for identifying genetic influences on particular withdrawal behaviors, which should reflect the influences of different constellations of genes. Published by Elsevier Inc.

  10. A Bayesian decision procedure for testing multiple hypotheses in DNA microarray experiments.

    Science.gov (United States)

    Gómez-Villegas, Miguel A; Salazar, Isabel; Sanz, Luis

    2014-02-01

    DNA microarray experiments require the use of multiple hypothesis testing procedures because thousands of hypotheses are simultaneously tested. We deal with this problem from a Bayesian decision theory perspective. We propose a decision criterion based on an estimation of the number of false null hypotheses (FNH), taking as an error measure the proportion of the posterior expected number of false positives with respect to the estimated number of true null hypotheses. The methodology is applied to a Gaussian model when testing bilateral hypotheses. The procedure is illustrated with both simulated and real data examples and the results are compared to those obtained by the Bayes rule when an additive loss function is considered for each joint action and the generalized loss 0-1 function for each individual action. Our procedure significantly reduced the percentage of false negatives whereas the percentage of false positives remains at an acceptable level.

  11. LOFT/L9-3, Loss of Fluid Test, Anticipated Transients with Multiple Failures

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the third of the NRC L9 series of experiments on Anticipated Transients with Multiple Failures. Loss-of-feedwater effects were studied. The experiment was conducted on 7 April 1982

  12. Rapid Aminoglycoside NP Test for Rapid Detection of Multiple Aminoglycoside Resistance in Enterobacteriaceae.

    Science.gov (United States)

    Nordmann, Patrice; Jayol, Aurélie; Dobias, Jan; Poirel, Laurent

    2017-04-01

    The rapid aminoglycoside NP (Nordmann/Poirel) test was developed to rapidly identify multiple aminoglycoside (AG) resistance in Enterobacteriaceae It is based on the detection of the glucose metabolism related to enterobacterial growth in the presence of a defined concentration of amikacin plus gentamicin. Formation of acid metabolites was evidenced by a color change (orange to yellow) of the red phenol pH indicator. The rapid aminoglycoside NP test was evaluated by using bacterial colonies of 18 AG-resistant isolates producing 16S rRNA methylases, 20 AG-resistant isolates expressing AG-modifying enzymes (acetyl-, adenyl-, and phosphotransferases), and 10 isolates susceptible to AG. Its sensitivity and specificity were 100% and 97%, respectively, compared to the broth dilution method, which was taken as the gold standard for determining aminoglycoside resistance. The test is inexpensive, rapid (<2 h), and implementable worldwide. Copyright © 2017 American Society for Microbiology.

  13. 20 Years of standard patch testing in an eczema population with focus on patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2007-01-01

    Results of standard patch tests performed with the same methodology in one centre are rarely available over a large time span. This gives the unique opportunity to study not only prevalence but also persistency of contact allergy and characterize subpopulations. The objectives were to investigate...... sensitivity rates and persistencies of patch test results and characterize patients with multiple contact allergies. A 20-year retrospective database-based study of 14 998 patients patch tested with the European Standard Series was performed. 34.5% were sensitized, primarily women. Sensitivity to nickel......(Me)isothiazolinone, and primin and poor for paraben mix. 5.1% were multiple allergic, primarily women, and 90% got diagnosed by the first test. Frequency of multiple allergies increased with age. More multiple- than mono/double-allergic patients were tested multiple times. Persistency and sensitivity rates in a Danish eczema...

  14. Measuring the Consistency in Change in Hepatitis B Knowledge among Three Different Types of Tests: True/False, Multiple Choice, and Fill in the Blanks Tests.

    Science.gov (United States)

    Sahai, Vic; Demeyere, Petra; Poirier, Sheila; Piro, Felice

    1998-01-01

    The recall of information about Hepatitis B demonstrated by 180 seventh graders was tested with three test types: (1) short-answer; (2) true/false; and (3) multiple-choice. Short answer testing was the most reliable. Suggestions are made for the use of short-answer tests in evaluating student knowledge. (SLD)

  15. An Application of Graphical Approach to Construct Multiple Testing Procedure in a Hypothetical Phase III Design

    Directory of Open Access Journals (Sweden)

    Naitee eTing

    2014-01-01

    Full Text Available Many multiple testing procedures (MTP have been developed in recent years. Among these new procedures, the graphical approach is flexible and easy to communicate with non-statisticians. A hypothetical Phase III clinical trial design is introduced in this manuscript to demonstrate how graphical approach can be applied in clinical product development. In this design, an active comparator is used. It is thought that this test drug under development could potentially be superior to this comparator. For comparison of efficacy, the primary endpoint is well established and widely accepted by regulatory agencies. However, an important secondary endpoint based on Phase II findings looks very promising. The target dose may have a good opportunity to deliver superiority to the comparator. Furthermore, a lower dose is included in case the target dose may demonstrate potential safety concerns. This Phase III study is designed as a non-inferiority trial with two doses, and two endpoints. This manuscript will illustrate how graphical approach is applied to this design in handling multiple testing issues.

  16. Defining and Developing "Critical Thinking" Through Devising and Testing Multiple Explanations of the Same Phenomenon

    Science.gov (United States)

    Etkina, Eugenia; Planinšič, Gorazd

    2015-10-01

    Most physics teachers would agree that one of the main reasons for her/his students to take physics is to learn to think critically. However, for years we have been assessing our students mostly on the knowledge of physics content (conceptually and quantitatively). Only recently have science educators started moving systematically towards achieving and assessing this critical thinking goal. In this paper we seek to show how guiding students to devise and test multiple explanations of observed phenomena can be used to improve their critical thinking.

  17. Pulse Jet Mixer Overblow Testing for Assessment of Loadings During Multiple Overblows

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Bontha, Jagannadha R.; Michener, Thomas E.; Nigl, Franz; Yokuda, Satoru T.; Leigh, Richard J.; Golovich, Elizabeth C.; Baumann, Aaron W.; Kurath, Dean E.; Hoza, Mark; Combs, William H.; Fort, James A.; Bredt, Ofelia P.

    2009-07-20

    The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities: pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste feed from the Hanford tank farms and separate it into 1) a high-volume, low-activity liquid stream stripped of most solids and radionuclides and 2) a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJMs) that will provide some or all of the mixing in the vessels. This technology was selected for use in so-called “black cell” regions of the WTP, where maintenance capability will not be available for the operating life of the WTP. PJM technology was selected for use in these regions because it has no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. This report contains the results of single and multiple PJM overblow tests conducted in a large, ~13 ft-diameter × 15-ft-tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. These single and multiple PJM overblow tests were conducted using water and a clay simulant to bound the lower and upper rheological properties of the waste streams anticipated to be processed in the WTP. Hydrodynamic pressures were measured at a number of locations in the test vessel using an array of nine pressure sensors and four hydrophones. These measurements were made under normal and limiting vessel operating conditions (i.e., maximum PJM fluid emptying velocity, maximum and minimum vessel

  18. Pulse Jet Mixer Overblow Testing for Assessment of Loadings During Multiple Overblows

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Bontha, Jagannadha R.; Michener, Thomas E.; Nigl, Franz; Yokuda, Satoru T.; Leigh, Richard J.; Golovich, Elizabeth C.; Baumann, Aaron W.; Kurath, Dean E.; Hoza, Mark; Combs, William H.; Fort, James A.; Bredt, Ofelia P.

    2008-03-03

    The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities: pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste feed from the Hanford tank farms and separate it into 1) a high-volume, low-activity liquid stream stripped of most solids and radionuclides and 2) a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJMs) that will provide some or all of the mixing in the vessels. This technology was selected for use in so-called “black cell” regions of the WTP, where maintenance capability will not be available for the operating life of the WTP. PJM technology was selected for use in these regions because it has no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. This report contains the results of single and multiple PJM overblow tests conducted in a large, ~13 ft-diameter × 15-ft-tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. These single and multiple PJM overblow tests were conducted using water and a clay simulant to bound the lower and upper rheological properties of the waste streams anticipated to be processed in the WTP. Hydrodynamic pressures were measured at a number of locations in the test vessel using an array of nine pressure sensors and four hydrophones. These measurements were made under normal and limiting vessel operating conditions (i.e., maximum PJM fluid emptying velocity, maximum and minimum vessel

  19. Comparing long-term results of PASAT and SDMT scores in relation to neuropsychological testing in multiple sclerosis

    NARCIS (Netherlands)

    Sonder, J.M.; Burggraaff, J.; Knol, D.L.; Polman, C.H.; Uitdehaag, B.M.J.

    2014-01-01

    Background and objectives: The Symbol Digit Modalities Test (SDMT) shows advantages over the Paced Auditory Serial Addition Test (PASAT) as a cognitive test in patients with multiple sclerosis (MS). To determine which of these tests is most valid and reliable over time as an indicator of the

  20. Estimating the Proportion of True Null Hypotheses in Multiple Testing Problems

    Directory of Open Access Journals (Sweden)

    Oluyemi Oyeniran

    2016-01-01

    Full Text Available The problem of estimating the proportion, π0, of the true null hypotheses in a multiple testing problem is important in cases where large scale parallel hypotheses tests are performed independently. While the problem is a quantity of interest in its own right in applications, the estimate of π0 can be used for assessing or controlling an overall false discovery rate. In this article, we develop an innovative nonparametric maximum likelihood approach to estimate π0. The nonparametric likelihood is proposed to be restricted to multinomial models and an EM algorithm is also developed to approximate the estimate of π0. Simulation studies show that the proposed method outperforms other existing methods. Using experimental microarray datasets, we demonstrate that the new method provides satisfactory estimate in practice.

  1. The test beamline of the European Spallation Source - Instrumentation development and wavelength frame multiplication

    DEFF Research Database (Denmark)

    Woracek, R.; Hofmann, T.; Bulat, M.

    2016-01-01

    which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor...... wavelength band between 1.6 A and 10 A by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components....... This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects....

  2. Detecting a Weak Association by Testing its Multiple Perturbations: a Data Mining Approach

    Science.gov (United States)

    Lo, Min-Tzu; Lee, Wen-Chung

    2014-05-01

    Many risk factors/interventions in epidemiologic/biomedical studies are of minuscule effects. To detect such weak associations, one needs a study with a very large sample size (the number of subjects, n). The n of a study can be increased but unfortunately only to an extent. Here, we propose a novel method which hinges on increasing sample size in a different direction-the total number of variables (p). We construct a p-based `multiple perturbation test', and conduct power calculations and computer simulations to show that it can achieve a very high power to detect weak associations when p can be made very large. As a demonstration, we apply the method to analyze a genome-wide association study on age-related macular degeneration and identify two novel genetic variants that are significantly associated with the disease. The p-based method may set a stage for a new paradigm of statistical tests.

  3. Deformable microparticles with multiple functions for drug delivery and device testing

    Science.gov (United States)

    Thula, Taili T.

    Since the HIV epidemic of the 1990s, researchers have attempted to develop a red blood cell analog. Even though some of these substitutes are now in Phase III of clinical trials, their use is limited by side effects and short half-life in the human body. As a result, there is still a need for an effective erythrocyte analog with minimum immunogenic and side effects, so that it can be used for multiple applications. Finding new approaches to develop more efficient blood substitutes will not only bring valuable advances in the clinical approach, but also in the area of in vitro testing of medical devices. We examined the feasibility of creating a deformable multi-functional, biodegradable, biocompatible particle for applications in drug delivery and device testing. As a preliminary evaluation, we synthesized different types of microcapsules using natural and synthetic polymers, various cross-linking agents, and diverse manufacturing techniques. After fully characterizing of each system, we determined the most promising red blood cell analog in terms of deformability, stability and toxicity. We also examined the encapsulation and release of bovine serum albumin (BSA) within these deformable particles. After removal of cross-linkers, zinc- and copper-alginate microparticles surrounded by multiple polyelectrolyte layers of chitosan oligosaccharide and alginate were deformable and remained stable under physiological pressures applied by the micropipette technique. In addition, multiple coatings decreased toxicity of heavy-metal crosslinked particles. BSA encapsulation and release from chitosan-alginate microspheres were contingent on the crosslinker and number of polyelectrolyte coatings, respectively. Further rheological studies are needed to determine how closely these particles simulate the behavior of erythrocytes. Also, studies on the encapsulation and release of different proteins, including hemoglobin, are needed to establish the desired controlled release of

  4. Validity of the Symbol Digit Modalities Test as a cognition performance outcome measure for multiple sclerosis.

    Science.gov (United States)

    Benedict, Ralph Hb; DeLuca, John; Phillips, Glenn; LaRocca, Nicholas; Hudson, Lynn D; Rudick, Richard

    2017-04-01

    Cognitive and motor performance measures are commonly employed in multiple sclerosis (MS) research, particularly when the purpose is to determine the efficacy of treatment. The increasing focus of new therapies on slowing progression or reversing neurological disability makes the utilization of sensitive, reproducible, and valid measures essential. Processing speed is a basic elemental cognitive function that likely influences downstream processes such as memory. The Multiple Sclerosis Outcome Assessments Consortium (MSOAC) includes representatives from advocacy organizations, Food and Drug Administration (FDA), European Medicines Agency (EMA), National Institute of Neurological Disorders and Stroke (NINDS), academic institutions, and industry partners along with persons living with MS. Among the MSOAC goals is acceptance and qualification by regulators of performance outcomes that are highly reliable and valid, practical, cost-effective, and meaningful to persons with MS. A critical step for these neuroperformance metrics is elucidation of clinically relevant benchmarks, well-defined degrees of disability, and gradients of change that are deemed clinically meaningful. This topical review provides an overview of research on one particular cognitive measure, the Symbol Digit Modalities Test (SDMT), recognized as being particularly sensitive to slowed processing of information that is commonly seen in MS. The research in MS clearly supports the reliability and validity of this test and recently has supported a responder definition of SDMT change approximating 4 points or 10% in magnitude.

  5. Within-day variability on short and long walking tests in persons with multiple sclerosis.

    Science.gov (United States)

    Feys, Peter; Bibby, Bo; Romberg, Anders; Santoyo, Carme; Gebara, Benoit; de Noordhout, Benoit Maertens; Knuts, Kathy; Bethoux, Francois; Skjerbæk, Anders; Jensen, Ellen; Baert, Ilse; Vaney, Claude; de Groot, Vincent; Dalgas, Ulrik

    2014-03-15

    To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Observational study. MS rehabilitation and research centers in Europe and US within RIMS (European network for best practice and research in MS rehabilitation). Ambulatory persons with MS (Expanded Disability Status Scale 0-6.5). Subjects of different centers performed walking tests at 3 time points during a single day. 10MWT, 2MWT and 6MWT at fastest speed and 10MWT at usual speed. Ninety-five percent limits of agreement were computed using a random effects model with individual pwMS as random effect. Following this model, retest scores are with 95% certainty within these limits of baseline scores. In 102 subjects, within-day variability was constant in absolute units for the 10MWT, 2MWT and 6MWT at fastest speed (+/-0.26, 0.16 and 0.15m/s respectively, corresponding to +/-19.2m and +/-54 m for the 2MWT and 6MWT) independent on the severity of ambulatory dysfunction. This implies a greater relative variability with increasing disability level, often above 20% depending on the applied test. The relative within-day variability of the 10MWT at usual speed was +/-31% independent of ambulatory function. Absolute values of within-day variability on walking tests at fastest speed were independent of disability level and greater with short compared to long walking tests. Relative within-day variability remained overall constant when measured at usual speed. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  6. Eye and hand motor interactions with the Symbol Digit Modalities Test in early multiple sclerosis.

    Science.gov (United States)

    Nygaard, Gro O; de Rodez Benavent, Sigrid A; Harbo, Hanne F; Laeng, Bruno; Sowa, Piotr; Damangir, Soheil; Bernhard Nilsen, Kristian; Etholm, Lars; Tønnesen, Siren; Kerty, Emilia; Drolsum, Liv; Inge Landrø, Nils; Celius, Elisabeth G

    2015-11-01

    Eye and hand motor dysfunction may be present early in the disease course of relapsing-remitting multiple sclerosis (RRMS), and can affect the results on visual and written cognitive tests. We aimed to test for differences in saccadic initiation time (SI time) between RRMS patients and healthy controls, and whether SI time and hand motor speed interacted with the written version of the Symbol Digit Modalities Test (wSDMT). Patients with RRMS (N = 44, age 35.1 ± 7.3 years), time since diagnosis < 3 years and matched controls (N = 41, age 33.2 ± 6.8 years) were examined with ophthalmological, neurological and neuropsychological tests, as well as structural MRI (white matter lesion load (WMLL) and brainstem lesions), visual evoked potentials (VEP) and eye-tracker examinations of saccades. SI time was longer in RRMS than controls (p < 0.05). SI time was not related to the Paced Auditory Serial Addition Test (PASAT), WMLL or to the presence of brainstem lesions. 9 hole peg test (9HP) correlated significantly with WMLL (r = 0.58, p < 0.01). Both SI time and 9HP correlated negatively with the results of wSDMT (r = -0.32, p < 0.05, r = -0.47, p < 0.01), but none correlated with the results of PASAT. RRMS patients have an increased SI time compared to controls. Cognitive tests results, exemplified by the wSDMT, may be confounded by eye and hand motor function. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Recall strategies for the verbal fluency test in patients with multiple sclerosis.

    Science.gov (United States)

    Velázquez-Cardoso, J; Marosi-Holczberger, E; Rodríguez-Agudelo, Y; Yañez-Tellez, G; Chávez-Oliveros, M

    2014-04-01

    Multiple sclerosis (MS) is a neurodegenerative disease characterised by inflammation and demyelination. It generates irreversible myelin changes, which in turn give rise to physical and cognitive disorders. The verbal fluency test (VF) has been shown to be a sensitive tool for detecting cognitive impairment in these patients. To compare quantitative and qualitative aspects of performance on semantic and phonological fluency tests between MS patients and healthy controls by analysing total words produced and strategies used (clusters and switching). We evaluated 46 patients with MS and 33 healthy controls using the VF test. The semantic VF task revealed no significant differences between groups; for the phonological task, patients demonstrated reduced word production (F [77]=2.286 P<.001) and poorer use of grouping strategies, resulting in more frequent switching (F [77]=3.808 P<.005). These results support using qualitative analysis for recall strategies, since the technique provides data about which components of the task are affected by brain damage. Clusters depend on the integrity of semantic memory, while switching has to do with developing effective search strategies, cognitive flexibility, and the ability to modify responses. Frontal lobe damage has been reported in MS, and this is consistent with results from the phonological VF test. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  8. Proving test on the performance of a Multiple-Excitation Simulator

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Ito, Tomohiro; Kojima, Nobuyuki; Sasaki, Yoichi; Abe, Hiroshi; Kuroda, Katsuhiko

    1995-01-01

    Seismic excitation test on large scale piping systems is scheduled to be carried out by the Nuclear power Engineering Corporation (NUPEC) using the large-scale, high-performance vibration table at the Tadotsu Engineering Laboratory, under the sponsorship of the Ministry of International Trade and Industry (MITI). In the test, the piping systems simulate the main steam piping system and the main feed water piping system in the nuclear power plants. In this study, a fundamental test was carried out to prove the performance of the Multiple Excitation Simulator which consists of the hydraulic actuator and the control system. An L-shaped piping system and a hydraulic actuator were installed on the shaking table. Acceleration and displacement generated by the actuator were measured. The performance of the actuator and the control system was discussed comparing the measured values and the target values on the time histories and the response spectrum of the acceleration. As a result, it was proved that the actuator and the control system have good performance and will be applicable to the verification test

  9. Post-Graduate Student Performance in "Supervised In-Class" vs. "Unsupervised Online" Multiple Choice Tests: Implications for Cheating and Test Security

    Science.gov (United States)

    Ladyshewsky, Richard K.

    2015-01-01

    This research explores differences in multiple choice test (MCT) scores in a cohort of post-graduate students enrolled in a management and leadership course. A total of 250 students completed the MCT in either a supervised in-class paper and pencil test or an unsupervised online test. The only statistically significant difference between the nine…

  10. The Relationship of Deep and Surface Study Approaches on Factual and Applied Test-Bank Multiple-Choice Question Performance

    Science.gov (United States)

    Yonker, Julie E.

    2011-01-01

    With the advent of online test banks and large introductory classes, instructors have often turned to textbook publisher-generated multiple-choice question (MCQ) exams in their courses. Multiple-choice questions are often divided into categories of factual or applied, thereby implicating levels of cognitive processing. This investigation examined…

  11. Methods for significance testing of categorical covariates in logistic regression models after multiple imputation: power and applicability analysis

    NARCIS (Netherlands)

    Eekhout, I.; Wiel, M.A. van de; Heymans, M.W.

    2017-01-01

    Background. Multiple imputation is a recommended method to handle missing data. For significance testing after multiple imputation, Rubin’s Rules (RR) are easily applied to pool parameter estimates. In a logistic regression model, to consider whether a categorical covariate with more than two levels

  12. Design of clinical trials involving multiple hypothesis tests with a common control.

    Science.gov (United States)

    Schou, I Manjula; Marschner, Ian C

    2017-07-01

    Randomized clinical trials comparing several treatments to a common control are often reported in the medical literature. For example, multiple experimental treatments may be compared with placebo, or in combination therapy trials, a combination therapy may be compared with each of its constituent monotherapies. Such trials are typically designed using a balanced approach in which equal numbers of individuals are randomized to each arm, however, this can result in an inefficient use of resources. We provide a unified framework and new theoretical results for optimal design of such single-control multiple-comparator studies. We consider variance optimal designs based on D-, A-, and E-optimality criteria, using a general model that allows for heteroscedasticity and a range of effect measures that include both continuous and binary outcomes. We demonstrate the sensitivity of these designs to the type of optimality criterion by showing that the optimal allocation ratios are systematically ordered according to the optimality criterion. Given this sensitivity to the optimality criterion, we argue that power optimality is a more suitable approach when designing clinical trials where testing is the objective. Weighted variance optimal designs are also discussed, which, like power optimal designs, allow the treatment difference to play a major role in determining allocation ratios. We illustrate our methods using two real clinical trial examples taken from the medical literature. Some recommendations on the use of optimal designs in single-control multiple-comparator trials are also provided. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis.

    Science.gov (United States)

    Rosenblum, Uri; Melzer, Itshak

    2017-01-01

    About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http

  14. Using the Coefficient of Determination "R"[superscript 2] to Test the Significance of Multiple Linear Regression

    Science.gov (United States)

    Quinino, Roberto C.; Reis, Edna A.; Bessegato, Lupercio F.

    2013-01-01

    This article proposes the use of the coefficient of determination as a statistic for hypothesis testing in multiple linear regression based on distributions acquired by beta sampling. (Contains 3 figures.)

  15. Feedback-related brain activity predicts learning from feedback in multiple-choice testing.

    Science.gov (United States)

    Ernst, Benjamin; Steinhauser, Marco

    2012-06-01

    Different event-related potentials (ERPs) have been shown to correlate with learning from feedback in decision-making tasks and with learning in explicit memory tasks. In the present study, we investigated which ERPs predict learning from corrective feedback in a multiple-choice test, which combines elements from both paradigms. Participants worked through sets of multiple-choice items of a Swahili-German vocabulary task. Whereas the initial presentation of an item required the participants to guess the answer, corrective feedback could be used to learn the correct response. Initial analyses revealed that corrective feedback elicited components related to reinforcement learning (FRN), as well as to explicit memory processing (P300) and attention (early frontal positivity). However, only the P300 and early frontal positivity were positively correlated with successful learning from corrective feedback, whereas the FRN was even larger when learning failed. These results suggest that learning from corrective feedback crucially relies on explicit memory processing and attentional orienting to corrective feedback, rather than on reinforcement learning.

  16. Design of PH-based accelerated life testing plans under multiple-stress-type

    International Nuclear Information System (INIS)

    Elsayed, E.A.; Zhang Hao

    2007-01-01

    Accelerated life testing (ALT) is used to obtain failure time data quickly under high stress levels in order to predict product life performance under design stress conditions. Most of the previous work on designing ALT plans is focused on the application of a single stress. However, as components or products become more reliable due to technological advances, it becomes more difficult to obtain significant amount of failure data within reasonable amount of time using single stress only. Multiple-stress-type ALTs have been employed as a means of overcoming such difficulties. In this paper, we design optimum multiple-stress-type ALT plans based on the proportional hazards model. The optimum combinations of stresses and their levels are determined such that the variance of the reliability estimate of the product over a specified period of time is minimized. The use of the model is illustrated using numerical example, and sensitivity analysis shows that the resultant optimum ALT plan is robust to the deviation in model parameters

  17. Force Concept Inventory-based multiple-choice test for investigating students’ representational consistency

    Directory of Open Access Journals (Sweden)

    Pasi Nieminen

    2010-08-01

    Full Text Available This study investigates students’ ability to interpret multiple representations consistently (i.e., representational consistency in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI, which makes use of nine items from the 1995 version of the Force Concept Inventory (FCI. These original FCI items were redesigned using various representations (such as motion map, vectorial and graphical, yielding 27 multiple-choice items concerning four central concepts underpinning the force concept: Newton’s first, second, and third laws, and gravitation. We provide some evidence for the validity and reliability of the R-FCI; this analysis is limited to the student population of one Finnish high school. The students took the R-FCI at the beginning and at the end of their first high school physics course. We found that students’ (n=168 representational consistency (whether scientifically correct or not varied considerably depending on the concept. On average, representational consistency and scientifically correct understanding increased during the instruction, although in the post-test only a few students performed consistently both in terms of representations and scientifically correct understanding. We also compared students’ (n=87 results of the R-FCI and the FCI, and found that they correlated quite well.

  18. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    International Nuclear Information System (INIS)

    Woodman, N.D.; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-01-01

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study

  19. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Woodman, N.D., E-mail: n.d.woodman@soton.ac.uk; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-04-15

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study.

  20. A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies

    Science.gov (United States)

    McClung, R. C.; Chell, G. G.; Millwater, H. R.; Russell, D. A.; Millwater, H. R.

    1999-01-01

    Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semielliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT versus SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.

  1. The benefit of self-testing and interleaving for synthesizing concepts across multiple physiology texts.

    Science.gov (United States)

    Linderholm, Tracy; Dobson, John; Yarbrough, Mary Beth

    2016-09-01

    A testing-based learning strategy is one that relies on the act of recalling (i.e., testing) information after exposure, and interleaving is a strategy in which the learning materials are presented in a serial order (e.g., texts 1, 2, 3, 1, 2, 3, 1, 2, 3) versus a blocked order (e.g., texts 1, 1, 1, 2, 2, 2, 3, 3, 3). Although both learning strategies have been thoroughly investigated, few studies have examined their additive effect with higher-order cognitive tasks such as the ability to identify themes across multiple texts, and none of those did so using physiology information. The purpose of the present study was to compare recall and thematic processing across five different physiology texts. Participants were randomly assigned to learn the texts using one of the following four learning strategies: 1) study-study-study (S-S-S) using a blocked order, 2) S-S-S using an interleaved order, 3) study-test-study (S-T-S) using a blocked order, and 4) S-T-S using an interleaved order. Over the course of the following week, the S-T-S groups had more stable recall of key text ideas compared with the S-S-S groups, and the S-T-S group had more stable recall of thematic information than the S-S-S group when interleaving was used as the presentation order. Copyright © 2016 The American Physiological Society.

  2. The Predictive Validity of using Admissions Testing and Multiple Mini-interviews in Undergraduate University Admissions

    DEFF Research Database (Denmark)

    Makransky, Guido; Havmose, Philip S.; Vang, Maria Louison

    2017-01-01

    The aim of this study was to evaluate the predictive validity of a two-step admissions procedure that included a cognitive ability test followed by multiple mini-interviews (MMI) used to assess non-cognitive skills compared to a grade-based admissions relative to subsequent drop-out rates...... and academic achievement after one and two years of study. The participants consisted of the entire population of 422 psychology students who were admitted to the University of Southern Denmark between 2010 and 2013. The results showed significantly lower drop-out rates after the first year of study, and non......-significant lower drop-out rates after the second year of study for the admission procedure that included the assessment of non-cognitive skills though the MMI. Furthermore, this admission procedure resulted in a significant lower risk of failing the final exam after the first and second year of study, compared...

  3. Quantitative analysis of the pendulum test: application to multiple sclerosis patients treated with botulinum toxin.

    Science.gov (United States)

    Bianchi, L; Monaldi, F; Paolucci, S; Iani, C; Lacquaniti, F

    1999-01-01

    The aim of this study was to develop quantitative analytical methods in the application of the pendulum test to both normal and spastic subjects. The lower leg was released by a torque motor from different starting positions. The resulting changes in the knee angle were fitted by means of a time-varying model. Stiffness and viscosity coefficients were derived for each half-cycle oscillation in both flexion and extension, and for all knee starting positions. This method was applied to the assessment of the effects of Botulinum toxin A (BTX) in progressive multiple sclerosis patients in a follow-up study. About half of the patients showed a significant decrement in stiffness and viscosity coefficients.

  4. Shared Authentic Leadership in Research Teams: Testing a Multiple Mediation Model.

    Science.gov (United States)

    Guenter, Hannes; Gardner, William L; Davis McCauley, Kelly; Randolph-Seng, Brandon; Prabhu, Veena P

    2017-12-01

    Research teams face complex leadership and coordination challenges. We propose shared authentic leadership (SAL) as a timely approach to addressing these challenges. Drawing from authentic and functional leadership theories, we posit a multiple mediation model that suggests three mechanisms whereby SAL influences team effectiveness: shared mental models (SMM), team trust, and team coordination. To test our hypotheses, we collected survey data on leadership and teamwork within 142 research teams that recently published an article in a peer-reviewed management journal. The results indicate team coordination represents the primary mediating mechanism accounting for the relationship between SAL and research team effectiveness. While teams with high trust and SMM felt more successful and were more satisfied, they were less successful in publishing in high-impact journals. We also found the four SAL dimensions (i.e., self-awareness, relational transparency, balanced processing, and internalized moral perspective) to associate differently with team effectiveness.

  5. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva; Esclerosis multiple test de los 4 humores: liquido cefalorraquideo, suero, lagrimas y saliva

    Energy Technology Data Exchange (ETDEWEB)

    Oehninger Gatti, C; Buzo Del Puerto, R; Chouza Antelo, C; Scotti Bianchi, C; Cibils, D; Alcantara Pelaez, J; Gomez, A; Heuguerot Oliveira, C

    1994-12-15

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [Spanish] Se estudiaron 4 fluidos biologicos de facil acceso a la exploracion inmune (liquido cefalorraquideo, suero, lagrimas y saliva) en 25 pacientes con Esclerosis Multiple (EM) obtenidos durante un empuje clinico de la enfermedad. El nivel del receptor de Interleukina-2 soluble (RsIL-2) se encontro significativamente aumentado en por lo menos 3 de estos 4 fluidos, en comparacion con el de los controles normales. La sensibilidad y especificidad de su determinacion para el diagnostico de la afeccion, fue mayor que la de otros parametros inmunoquimicos - distribucion oligoclonal (DO) de inmunoglobulinas (Ig), disbalance de cadenas livianas - y estudios electrofisiologicos -potenciales evocados-. Este metodo es utilizado para establecer un diagnostico mas certero de la Esclerosis Multiple asi como tambien para monitorizar su actividad biologica junto con la resonancia magnetica nuclear (RMN)(Author)

  6. The relationship between Test Takers’ Multiple Intelligences and Their Performance on the Reading Sections of TOEFL and IELTS

    Directory of Open Access Journals (Sweden)

    Minoo Alemi

    2010-04-01

    Full Text Available The present study aimed at investigating the hypothetical relationship between the multiple intelligences of test takers and their performance on the reading sections of TOEFL and IELTS. Howard Gardner’s theory of multiple intelligences suggests that intelligence is not a single and solely inborn capacity, rather a multiple construct which is only partly genetic, and can be crystallized or paralyzed over one’s lifetime. Based on the theory, there are eight types of intelligence: linguistic, mathematical, musical, bodily, spatial, intrapersonal, interpersonal and naturalist, but the list is not exhaustive. The multiple intelligences of test takers were estimated by means of MIDAS, the Multiple Intelligences Developmental Assessment Scales, developed by Shearer (1994. Subsequently, the bias detection for the reading section of TOEFL was carried out on 90 participants, and this subtest was found to correlate positively with linguistic and logical intelligences. By the same token, 89 out of the 163 participants in the study were included in the analysis of the relationship between the multiple intelligences of test takers and their performance on the reading section of IELTS, and this test proved biased toward linguistic and spatial intelligences. The implications concern the inadequacy of the definition of language proficiency .Moreover, Measurement-Driven Instruction courses and preparatory materials of the two proficiency tests, TOEFL and IELTS, can benefit from the results of the study by being designed in such a way as to represent the intelligences which are positively correlated with performance on the tests in question.

  7. Multiple sample setup for testing the hydrothermal stability of adsorbents in thermal energy storage applications

    International Nuclear Information System (INIS)

    Fischer, Fabian; Laevemann, Eberhard

    2015-01-01

    Thermal energy storage based on adsorption and desorption of water on an adsorbent can achieve high energy storage densities. Many adsorbents lose adsorption capacity when operated under unfavourable hydrothermal conditions during adsorption and desorption. The stability of an adsorbent against stressing hydrothermal conditions is a key issue for its usability in adsorption thermal energy storage. We built an experimental setup that simultaneously controls the hydrothermal conditions of 16 samples arranged in a matrix of four temperatures and four water vapour pressures. This setup allows the testing of potential adsorbents between temperatures of 50 °C and 350 °C and water vapour pressures of up to 32 kPa. A measurement procedure that allows the detection of the hydrothermal stability of an adsorbent after defined time spans has been designed. We verified the functionality of the multiple sample measurements with a microporous adsorbent, a zeolite NaMSX. The hydrothermal stability of this zeolite is tested by water uptake measurements. A standard deviation lower than 1% of the 16 samples for detecting the hydrothermal stability enables setting different conditions in each sample cell. Further, we compared the water uptake measurements by measuring their adsorption isotherms with the volumetric device BELSORP Aqua 3 from Bel Japan. (paper)

  8. Abbreviation modalities of nitrogen multiple-breath washout tests in school children with obstructed lung disease

    DEFF Research Database (Denmark)

    Green, Kent; Ejlertsen, Jacob S; Madsen, Astrid

    2016-01-01

    , the lung clearance index, calculated as lung volume turnovers required to reach 2.5% of the starting N2 concentration (LCI2.5 ). METHODS: Cross-sectional study of triplicate N2 MBW measurements obtained in cystic fibrosis (CF) patients (N = 60), primary ciliary dyskinesia (PCD) patients (N = 28......RATIONALE: Nitrogen multiple-breath washout (N2 MBW) is a promising tool for assessing early lung damage in children with chronic obstructive pulmonary disease, but it can be a time-consuming procedure. We compared alternative test-shortening endpoints with the most commonly reported N2 MBW outcome...... MBW runs in each session. N2 MBW endpoints were analyzed as z-scores calculated from healthy controls. RESULTS: In PCD, Cn@TO6 and LCI2.5 exhibited similar values (mean [95%CI] difference: 0.33 [-0.24; 0.90] z-scores), reducing the test duration by one-third (5.4 min; 95%CI: 4.0; 6.8). All other...

  9. Preschool Multiple-Breath Washout Testing. An Official American Thoracic Society Technical Statement.

    Science.gov (United States)

    Robinson, Paul D; Latzin, Philipp; Ramsey, Kathryn A; Stanojevic, Sanja; Aurora, Paul; Davis, Stephanie D; Gappa, Monika; Hall, Graham L; Horsley, Alex; Jensen, Renee; Lum, Sooky; Milla, Carlos; Nielsen, Kim G; Pittman, Jessica E; Rosenfeld, Margaret; Singer, Florian; Subbarao, Padmaja; Gustafsson, Per M; Ratjen, Felix

    2018-03-01

    Obstructive airway disease is nonuniformly distributed throughout the bronchial tree, although the extent to which this occurs can vary among conditions. The multiple-breath washout (MBW) test offers important insights into pediatric lung disease, not available through spirometry or resistance measurements. The European Respiratory Society/American Thoracic Society inert gas washout consensus statement led to the emergence of validated commercial equipment for the age group 6 years and above; specific recommendations for preschool children were beyond the scope of the document. Subsequently, the focus has shifted to MBW applications within preschool subjects (aged 2-6 yr), where a "window of opportunity" exists for early diagnosis of obstructive lung disease and intervention. This preschool-specific technical standards document was developed by an international group of experts, with expertise in both custom-built and commercial MBW equipment. A comprehensive review of published evidence was performed. Recommendations were devised across areas that place specific age-related demands on MBW systems. Citing evidence where available in the literature, recommendations are made regarding procedures that should be used to achieve robust MBW results in the preschool age range. The present work also highlights the important unanswered questions that need to be addressed in future work. Consensus recommendations are outlined to direct interested groups of manufacturers, researchers, and clinicians in preschool device design, test performance, and data analysis for the MBW technique.

  10. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    International Nuclear Information System (INIS)

    Woracek, R.; Hofmann, T.; Bulat, M.; Sales, M.; Habicht, K.; Andersen, K.; Strobl, M.

    2016-01-01

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  11. The utility of a 5(th) nap in multiple sleep latency test.

    Science.gov (United States)

    Muza, Rexford; Lykouras, Dimosthenis; Rees, Kate

    2016-02-01

    This is the first study that aimed to look specifically at the utility of the 5(th) nap in the multiple sleep latency test (MSLT), a test used to assist in the diagnosis of narcolepsy. Data was retrospectively collected from the Sleep Disorders Centre of a Tertiary Hospital on patients that had a 5(th) nap during their MSLT from the 08(th) November 2011 to 12(th) November 2014. Fifty-three patients had a 5(th) nap performed out of 378 MSLT studies. In 16% of cases a diagnosis of narcolepsy was given directly due to the inclusion of the 5(th) nap on the MSLT. Here a 5(th) nap allowed diagnostic criteria of mean sleep latency 2 SOREMPS to be met. In 53% of cases the mean sleep latency increased due to 5(th) nap inclusion; the mean sleep latency of the first four naps was 5.6 vs. 6.7 after inclusion of the 5(th) nap. The 5(th) nap is not often performed within the MSLT studies. Our study shows that only a few patients may benefit from a 5(th) nap opportunity which also led to increase of the mean sleep latency at the expense of extra time, cost, labour and increased patient anxiety.

  12. Identification of Misconceptions through Multiple Choice Tasks at Municipal Chemistry Competition Test

    Directory of Open Access Journals (Sweden)

    Dušica D Milenković

    2016-01-01

    Full Text Available In this paper, the level of conceptual understanding of chemical contents among seventh grade students who participated in the municipal Chemistry competition in Novi Sad, Serbia, in 2013 have been examined. Tests for the municipal chemistry competition were used as a measuring instrument, wherein only multiple choice tasks were considered and analyzed. Determination of the level of conceptual understanding of the tested chemical contents was based on the calculation of the frequency of choosing the correct answers. Thereby, identification of areas of satisfactory conceptual understanding, areas of roughly adequate performance, areas of inadequate performance, and areas of quite inadequate performance have been conducted. On the other hand, the analysis of misconceptions was based on the analysis of distractors. The results showed that satisfactory level of conceptual understanding and roughly adequate performance characterize majority of contents, which was expected since only the best students who took part in the contest were surveyed. However, this analysis identified a large number of misunderstandings, as well. In most of the cases, these misconceptions were related to the inability to distinguish elements, compounds, homogeneous and heterogeneous mixtures. Besides, it is shown that students are not familiar with crystal structure of the diamond, and with metric prefixes. The obtained results indicate insufficient visualization of the submicroscopic level in school textbooks, the imprecise use of chemical language by teachers and imprecise use of language in chemistry textbooks.

  13. Decision making under internal uncertainty: the case of multiple-choice tests with different scoring rules.

    Science.gov (United States)

    Bereby-Meyer, Yoella; Meyer, Joachim; Budescu, David V

    2003-02-01

    This paper assesses framing effects on decision making with internal uncertainty, i.e., partial knowledge, by focusing on examinees' behavior in multiple-choice (MC) tests with different scoring rules. In two experiments participants answered a general-knowledge MC test that consisted of 34 solvable and 6 unsolvable items. Experiment 1 studied two scoring rules involving Positive (only gains) and Negative (only losses) scores. Although answering all items was the dominating strategy for both rules, the results revealed a greater tendency to answer under the Negative scoring rule. These results are in line with the predictions derived from Prospect Theory (PT) [Econometrica 47 (1979) 263]. The second experiment studied two scoring rules, which allowed respondents to exhibit partial knowledge. Under the Inclusion-scoring rule the respondents mark all answers that could be correct, and under the Exclusion-scoring rule they exclude all answers that might be incorrect. As predicted by PT, respondents took more risks under the Inclusion rule than under the Exclusion rule. The results illustrate that the basic process that underlies choice behavior under internal uncertainty and especially the effect of framing is similar to the process of choice under external uncertainty and can be described quite accurately by PT. Copyright 2002 Elsevier Science B.V.

  14. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    Energy Technology Data Exchange (ETDEWEB)

    Woracek, R., E-mail: robin.woracek@esss.se [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Hofmann, T.; Bulat, M. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Sales, M. [Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark); Habicht, K. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Andersen, K. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Strobl, M. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark)

    2016-12-11

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  15. A new powerful non-parametric two-stage approach for testing multiple phenotypes in family-based association studies

    NARCIS (Netherlands)

    Lange, C; Lyon, H; DeMeo, D; Raby, B; Silverman, EK; Weiss, ST

    2003-01-01

    We introduce a new powerful nonparametric testing strategy for family-based association studies in which multiple quantitative traits are recorded and the phenotype with the strongest genetic component is not known prior to the analysis. In the first stage, using a population-based test based on the

  16. "None of the above" as a correct and incorrect alternative on a multiple-choice test: implications for the testing effect.

    Science.gov (United States)

    Odegard, Timothy N; Koen, Joshua D

    2007-11-01

    Both positive and negative testing effects have been demonstrated with a variety of materials and paradigms (Roediger & Karpicke, 2006b). The present series of experiments replicate and extend the research of Roediger and Marsh (2005) with the addition of a "none-of-the-above" response option. Participants (n=32 in both experiments) read a set of passages, took an initial multiple-choice test, completed a filler task, and then completed a final cued-recall test (Experiment 1) or multiple-choice test (Experiment 2). Questions were manipulated on the initial multiple-choice test by adding a "none-of-the-above" response alternative (choice "E") that was incorrect ("E" Incorrect) or correct ("E" Correct). The results from both experiments demonstrated that the positive testing effect was negated when the "none-of-the-above" alternative was the correct response on the initial multiple-choice test, but was still present when the "none-of-the-above" alternative was an incorrect response.

  17. False discovery rate control incorporating phylogenetic tree increases detection power in microbiome-wide multiple testing.

    Science.gov (United States)

    Xiao, Jian; Cao, Hongyuan; Chen, Jun

    2017-09-15

    Next generation sequencing technologies have enabled the study of the human microbiome through direct sequencing of microbial DNA, resulting in an enormous amount of microbiome sequencing data. One unique characteristic of microbiome data is the phylogenetic tree that relates all the bacterial species. Closely related bacterial species have a tendency to exhibit a similar relationship with the environment or disease. Thus, incorporating the phylogenetic tree information can potentially improve the detection power for microbiome-wide association studies, where hundreds or thousands of tests are conducted simultaneously to identify bacterial species associated with a phenotype of interest. Despite much progress in multiple testing procedures such as false discovery rate (FDR) control, methods that take into account the phylogenetic tree are largely limited. We propose a new FDR control procedure that incorporates the prior structure information and apply it to microbiome data. The proposed procedure is based on a hierarchical model, where a structure-based prior distribution is designed to utilize the phylogenetic tree. By borrowing information from neighboring bacterial species, we are able to improve the statistical power of detecting associated bacterial species while controlling the FDR at desired levels. When the phylogenetic tree is mis-specified or non-informative, our procedure achieves a similar power as traditional procedures that do not take into account the tree structure. We demonstrate the performance of our method through extensive simulations and real microbiome datasets. We identified far more alcohol-drinking associated bacterial species than traditional methods. R package StructFDR is available from CRAN. chen.jun2@mayo.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  18. Caffeine reversal of ethanol effects on the multiple sleep latency test, memory, and psychomotor performance.

    Science.gov (United States)

    Drake, Christopher L; Roehrs, Timothy; Turner, Lauren; Scofield, Holly M; Roth, Thomas

    2003-02-01

    Caffeine has been shown to reverse some of the performance-impairing effects of ethanol. However, it is not known whether this antagonistic effect of caffeine is mediated by a reduction in sleepiness. The present study assessed physiological alertness/sleepiness, memory, and psychomotor performance following the administration of placebo, ethanol, and caffeine+ethanol combinations. A total of 13 healthy individuals (21-35 years old) underwent four conditions presented in a Latin Square Design: placebo-placebo, ethanol (0.5 g/kg)-placebo, ethanol (0.5 g/kg)-caffeine 150 mg, and ethanol (0.5 g/kg)-caffeine 300-mg. The Multiple Sleep Latency Test (MSLT), psychomotor performance battery, memory test, and mood/sleepiness questionnaires were administered following each condition. The peak breadth ethanol concentration (BrEC) was 0.043+/-0.0197% and did not differ among the three caffeine treatments. As expected, ethanol reduced mean latency on the MSLT. The lowest caffeine dose reversed this effect and the highest dose increased mean latency (greater alertness) significantly beyond placebo levels. Ethanol also impaired psychomotor performance and memory. The 300-mg caffeine dose restored performance and memory measures to placebo levels. Although visual analog ratings of dizziness were increased by ethanol, they were not diminished by either caffeine dose. In conclusion, Low-dose caffeine prevented the sleepiness and performance impairment associated with a moderate dose of ethanol. Thus, caffeine, similar to other stimulants, can reverse the physiologically sedating effects of ethanol, although other negative effects remain.

  19. Exposure to Community Violence and Sexual Behaviors Among African American Youth: Testing Multiple Pathways.

    Science.gov (United States)

    Voisin, Dexter R; Hotton, Anna; Neilands, Torsten

    2018-01-01

    African American youth bear a disproportionate burden of sexually transmitted infections. A growing number of studies document that youth exposure to community violence and sexual behaviors are highly correlated. Despite such growing evidence, only a few studies have empirically tested conceptually driven pathways that may account for such relationships. This study seeks to address that gap by exploring multiple pathways linking exposure to community violence and youth sexual behaviors. Using an existing sample of 563 African American youth attending high school, we examined whether possible links between exposure to community violence and sexual activity, sexual risk behaviors were mediated by aggression, low student-teacher connectedness, and negative peer norms. Major findings indicated indirect relationships between exposures to community violence and both sexual activity and risky sex, mediated by aggression and negative peer norms with no significant differences based on gender or socioeconomic status. Overall findings also indicated a significant indirect effect of aggression to risky sex via negative peer norms and from community violence to risky peer norms via aggression. By illuminating ways that community violence, aggression, peer norms, and sexual behaviors are dynamically interrelated, these findings have significant implications for future research and intervention initiatives aimed at addressing the different pathways.

  20. Information processing speed and attention in multiple sclerosis: Reconsidering the Attention Network Test (ANT).

    Science.gov (United States)

    Roth, Alexandra K; Denney, Douglas R; Lynch, Sharon G

    2015-01-01

    The Attention Network Test (ANT) assesses attention in terms of discrepancies between response times to items that differ in the burden they place on some facet of attention. However, simple arithmetic difference scores commonly used to capture these discrepancies fail to provide adequate control for information processing speed, leading to distorted findings when patient and control groups differ markedly in the speed with which they process and respond to stimulus information. This study examined attention networks in patients with multiple sclerosis (MS) using simple difference scores, proportional scores, and residualized scores that control for processing speed through statistical regression. Patients with relapsing-remitting (N = 20) or secondary progressive (N = 20) MS and healthy controls (N = 40) of similar age, education, and gender completed the ANT. Substantial differences between patients and controls were found on all measures of processing speed. Patients exhibited difficulties in the executive control network, but only when difference scores were considered. When deficits in information processing speed were adequately controlled using proportional or residualized score, deficits in the alerting network emerged. The effect sizes for these deficits were notably smaller than those for overall information processing speed and were also limited to patients with secondary progressive MS. Deficits in processing speed are more prominent in MS than those involving attention, and when the former are properly accounted for, differences in the latter are confined to the alerting network.

  1. Multiplicity distributions of gluon and quark jets and a test of QCD analytic calculations

    International Nuclear Information System (INIS)

    Gary, J. William

    1999-01-01

    Gluon jets are identified in e + e - hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The mean and first few higher moments of the gluon jet charged particle multiplicity distribution are compared to the analogous results found for light quark (uds) jets, also defined inclusively. Large differences are observed between the mean, skew and curtosis values of the gluon and quark jets, but not between their dispersions. The cumulant factorial moments of the distributions are also measured, and are used to test the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the separated gluon and quark jet cumulant moments compared to a next-to-leading order calculation without energy conservation. There is good quantitative agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets. The data sample used is the LEP-1 sample of the OPAL experiment at LEP

  2. Multiplicity distributions of gluon and quark jets and a test of QCD analytic calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gary, J. William

    1999-03-01

    Gluon jets are identified in e{sup +}e{sup -} hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The mean and first few higher moments of the gluon jet charged particle multiplicity distribution are compared to the analogous results found for light quark (uds) jets, also defined inclusively. Large differences are observed between the mean, skew and curtosis values of the gluon and quark jets, but not between their dispersions. The cumulant factorial moments of the distributions are also measured, and are used to test the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the separated gluon and quark jet cumulant moments compared to a next-to-leading order calculation without energy conservation. There is good quantitative agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets. The data sample used is the LEP-1 sample of the OPAL experiment at LEP.

  3. Multiplicity distributions of gluon and quark jets and a test of QCD analytic calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gary, J.W. [California Univ., Riverside, CA (United States). Dept. of Physics

    1999-03-01

    Gluon jets are identified in e{sup +}e{sup -} hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The mean and first few higher moments of the gluon jet charged particle multiplicity distribution are compared to the analogous results found for light quark (uds) jets, also defined inclusively. Large differences are observed between the mean, skew and curtosis values of the gluon and quark jets, but not between their dispersions. The cumulant factorial moments of the distributions are also measured, and are used to test the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the separated gluon and quark jet cumulant moments compared to a next-to-leading order calculation without energy conservation. There is good quantitative agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets. The data sample used is the LEP-1 sample of the OPAL experiment at LEP. (orig.) 6 refs.

  4. Multiplicity distributions of gluon and quark jets and a test of QCD analytic calculations

    International Nuclear Information System (INIS)

    Gary, J.W.

    1999-01-01

    Gluon jets are identified in e + e - hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The mean and first few higher moments of the gluon jet charged particle multiplicity distribution are compared to the analogous results found for light quark (uds) jets, also defined inclusively. Large differences are observed between the mean, skew and curtosis values of the gluon and quark jets, but not between their dispersions. The cumulant factorial moments of the distributions are also measured, and are used to test the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the separated gluon and quark jet cumulant moments compared to a next-to-leading order calculation without energy conservation. There is good quantitative agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets. The data sample used is the LEP-1 sample of the OPAL experiment at LEP. (orig.)

  5. Multiplicity distributions of gluon and quark jets and a test of QCD analytic calculations

    Science.gov (United States)

    Gary, J. William

    1999-03-01

    Gluon jets are identified in e +e - hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon hets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The mean and first few higher moments of the gluon jet charged particle multiplicity distribution are compared to the analogous results found for light quark (uds) jets, also defined inclusively. Large differences are observed between the mean, skew and curtosis values of the gluon and quark jets, but not between their dispersions. The cumulant factorial moments of the distributions are also measured, and are used to test the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the separated gluon and quark jet cumulant moments compared to a next-to-leading order calculation without energy conservation. There is good quantitative agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets. The data sample used is the LEP-1 sample of the OPAL experiment at LEP.

  6. Testing a multiple mediator model of the effect of childhood sexual abuse on adolescent sexual victimization.

    Science.gov (United States)

    Bramsen, Rikke H; Lasgaard, Mathias; Koss, Mary P; Shevlin, Mark; Elklit, Ask; Banner, Jytte

    2013-01-01

    The present study modeled the direct relationship between child sexual abuse (CSA) and adolescent peer-to-peer sexual victimization (APSV) and the mediated effect via variables representing the number of sexual partners, sexual risk behavior, and signaling sexual boundaries. A cross-sectional study on the effect of CSA on APSV was conducted, utilizing a multiple mediator model. Mediated and direct effects in the model were estimated employing Mplus using bootstrapped percentile based confidence intervals to test for significance of mediated effects. The study employed 327 Danish female adolescents with a mean age of 14.9 years (SD = 0.5). The estimates from the mediational model indicated full mediation of the effect of CSA on APSV via number of sexual partners and sexual risk behavior. The current study suggests that the link between CSA and APSV was mediated by sexual behaviors specifically pertaining to situations of social peer interaction, rather than directly on prior experiences of sexual victimization. The present study identifies a modifiable target area for intervention to reduce adolescent sexual revictimization. © 2013 American Orthopsychiatric Association.

  7. Assessment of SPACE code for multiple failure accident: 1% Cold Leg Break LOCA with HPSI failure at ATLAS Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Lee, Seung Wook; Kim, Kyung-Doo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Design extension conditions (DECs) is a popular key issue after the Fukushima accident. In a viewpoint of the reinforcement of the defense in depth concept, a high-risk multiple failure accident should be reconsidered. The target scenario of ATLAS A5.1 test was LSTF (Large Scale Test Facility) SB-CL-32 test, a 1% SBLOCA with total failure of high pressure safety injection (HPSI) system of emergency core cooling system (ECCS) and secondary side depressurization as the accident management (AM) action, as a counterpart test. As the needs to prepare the DEC accident because of a multiple failure of the present NPPs are emphasized, the capability of SPACE code, just like other system analysis code, is required to expand the DEC area. The objectives of this study is to validate the capability of SPACE code for a DEC scenario, which represents multiple failure accident like as a SBLOCA with HPSI fail. Therefore, the ATLAS A5.1 test scenario was chosen. As the needs to prepare the DEC accident because of a multiple failure of operating NPPs are emphasized, the capability of SPACE code is needed to expand the DEC area. So the capability of SPACE code was validated for one of a DEC scenario. The target scenario was selected as the ATLAS A5.1 test, which is a 1% SBLOCA with total failure of HPSI system of ECCS and secondary side depressurization. Through the sensitivity study on discharge coefficient of break flow, the best fit of integrated mass was found. Using the coefficient, the ATLAS A5.1 test was analyzed using the SPACE code. The major thermal hydraulic parameters such as the system pressure, temperatures were compared with the test and have a good agreement. Through the simulation, it was concluded that the SPACE code can effectively simulate one of multiple failure accidents like as SBLOCA with HPSI failure accident.

  8. Science Library of Test Items. Volume Twenty-Two. A Collection of Multiple Choice Test Items Relating Mainly to Skills.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  9. Science Library of Test Items. Volume Eighteen. A Collection of Multiple Choice Test Items Relating Mainly to Chemistry.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  10. Science Library of Test Items. Volume Twenty. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 1.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  11. Science Library of Test Items. Volume Seventeen. A Collection of Multiple Choice Test Items Relating Mainly to Biology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  12. Science Library of Test Items. Volume Nineteen. A Collection of Multiple Choice Test Items Relating Mainly to Geology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  13. A semi-field approach to testing effects of fresh pesticide residues on bees in multiple-rate test

    NARCIS (Netherlands)

    Bakker, F.; Calis, J.N.M.

    2003-01-01

    We describe a semi-field cage test specifically designed to test effects of delayed exposure to plant protection products. The trial involved the use of standardised mini-beehives. The principle of the trial was to prepare two groups of potted test plants per treatment. The first group of plants

  14. Testing Group Mean Differences of Latent Variables in Multilevel Data Using Multiple-Group Multilevel CFA and Multilevel MIMIC Modeling.

    Science.gov (United States)

    Kim, Eun Sook; Cao, Chunhua

    2015-01-01

    Considering that group comparisons are common in social science, we examined two latent group mean testing methods when groups of interest were either at the between or within level of multilevel data: multiple-group multilevel confirmatory factor analysis (MG ML CFA) and multilevel multiple-indicators multiple-causes modeling (ML MIMIC). The performance of these methods were investigated through three Monte Carlo studies. In Studies 1 and 2, either factor variances or residual variances were manipulated to be heterogeneous between groups. In Study 3, which focused on within-level multiple-group analysis, six different model specifications were considered depending on how to model the intra-class group correlation (i.e., correlation between random effect factors for groups within cluster). The results of simulations generally supported the adequacy of MG ML CFA and ML MIMIC for multiple-group analysis with multilevel data. The two methods did not show any notable difference in the latent group mean testing across three studies. Finally, a demonstration with real data and guidelines in selecting an appropriate approach to multilevel multiple-group analysis are provided.

  15. Shared Authentic Leadership in Research Teams: Testing a Multiple Mediation Model

    NARCIS (Netherlands)

    Günter, Hannes; Gardner, William L.; Davis McCauley, Kelly; Randolph-Seng, Brandon; P. Prahbu, Veena

    2017-01-01

    Research teams face complex leadership and coordination challenges. We propose shared authentic leadership (SAL) as a timely approach to addressing these challenges. Drawing from authentic and functional leadership theories, we posit a multiple mediation model that suggests three mechanisms whereby

  16. Solar test of Dirac's large number hypothesis. [multiplicative creation model for solar evolution

    Science.gov (United States)

    Chin, C.-W.; Stothers, R.

    1975-01-01

    An investigation is conducted regarding the implications of Dirac's theories (1973, 1974) concerning the creation of new matter. It is found that Dirac's theory of multiplicative creation, but not his theory of additive creation, is not in contradiction with known facts about the sun. According to the theory of additive creation, matter is formed uniformly throughout space. The concept of multiplicative creation implies that existing matter multiplies itself in proportion to the amount of matter already present.

  17. Gender and Ethnicity Differences in Multiple-Choice Testing. Effects of Self-Assessment and Risk-Taking Propensity

    Science.gov (United States)

    1993-05-01

    correctness of the response provides I some advantages. They are: i 1. Increased reliability of the test; 2. Examinees pay more attention to the multiple...their choice 3 of test date. Each sign up sheet was divided into four cells: Non-Hispanic males and females and Hispanic males and females. 3 I I I...certain prestige and financial rewards; or entering a conservatory of music for advanced training with a well-known pianist . Mr. H realizes that even

  18. Effectiveness of Guided Multiple Choice Objective Questions Test on Students' Academic Achievement in Senior School Mathematics by School Location

    Science.gov (United States)

    Igbojinwaekwu, Patrick Chukwuemeka

    2015-01-01

    This study investigated, using pretest-posttest quasi-experimental research design, the effectiveness of guided multiple choice objective questions test on students' academic achievement in Senior School Mathematics, by school location, in Delta State Capital Territory, Nigeria. The sample comprised 640 Students from four coeducation secondary…

  19. Multiple unit root tests under uncertainty over the initial condition : some powerful modifications

    NARCIS (Netherlands)

    Hanck, C.

    We modify the union-of-rejection unit root test of Harvey et al. "Unit Root Testing in Practice: Dealing with Uncertainty over the Trend and Initial Condition" (Harvey, Econom Theory 25:587-636, 2009). This test rejects if either of two different unit root tests rejects but controls the inherent

  20. A SAS(®) macro implementation of a multiple comparison post hoc test for a Kruskal-Wallis analysis.

    Science.gov (United States)

    Elliott, Alan C; Hynan, Linda S

    2011-04-01

    The Kruskal-Wallis (KW) nonparametric analysis of variance is often used instead of a standard one-way ANOVA when data are from a suspected non-normal population. The KW omnibus procedure tests for some differences between groups, but provides no specific post hoc pair wise comparisons. This paper provides a SAS(®) macro implementation of a multiple comparison test based on significant Kruskal-Wallis results from the SAS NPAR1WAY procedure. The implementation is designed for up to 20 groups at a user-specified alpha significance level. A Monte-Carlo simulation compared this nonparametric procedure to commonly used parametric multiple comparison tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Compressed Sensing mm-Wave SAR for Non-Destructive Testing Applications Using Multiple Weighted Side Information

    Directory of Open Access Journals (Sweden)

    Mathias Becquaert

    2018-05-01

    Full Text Available This work explores an innovative strategy for increasing the efficiency of compressed sensing applied on mm-wave SAR sensing using multiple weighted side information. The approach is tested on synthetic and on real non-destructive testing measurements performed on a 3D-printed object with defects while taking advantage of multiple previous SAR images of the object with different degrees of similarity. The tested algorithm attributes autonomously weights to the side information at two levels: (1 between the components inside the side information and (2 between the different side information. The reconstruction is thereby almost immune to poor quality side information while exploiting the relevant components hidden inside the added side information. The presented results prove that, in contrast to common compressed sensing, good SAR image reconstruction is achieved at subsampling rates far below the Nyquist rate. Moreover, the algorithm is shown to be much more robust for low quality side information compared to coherent background subtraction.

  2. Development test of multiple die with hydraulic compensation and auto lubrication

    International Nuclear Information System (INIS)

    Chen Mengyou; Zhang Xichang; Zhu Ninghua; Liu Zichang

    1988-05-01

    Multiple die with hydraulic compensating device adopts the design of multidies gathering in a common grease cavity, using high temperature lubricating grease as the pressure compensating medium. According to Pascal's Law, each die will receive equal pressure during the process of pressing. Such device changes the equi-volume pressing mode of single mechanical die to equipressure pressing mode of multiple die in nuclear fuel element production, thus improves the quality and raises the quantity of nuclear fuel and powder ceramic products, giving a better economic benefit

  3. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion.

    Science.gov (United States)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-09-02

    Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    International Nuclear Information System (INIS)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-01-01

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers

  5. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng, E-mail: qschen@ujs.edu.cn

    2014-09-02

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers.

  6. Force Concept Inventory-Based Multiple-Choice Test for Investigating Students' Representational Consistency

    Science.gov (United States)

    Nieminen, Pasi; Savinainen, Antti; Viiri, Jouni

    2010-01-01

    This study investigates students' ability to interpret multiple representations consistently (i.e., representational consistency) in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI), which makes use of nine items from the 1995 version of the Force Concept Inventory…

  7. Examining the Prediction of Reading Comprehension on Different Multiple-Choice Tests

    Science.gov (United States)

    Andreassen, Rune; Braten, Ivar

    2010-01-01

    In this study, 180 Norwegian fifth-grade students with a mean age of 10.5 years were administered measures of word recognition skills, strategic text processing, reading motivation and working memory. Six months later, the same students were given three different multiple-choice reading comprehension measures. Based on three forced-order…

  8. Qualification of new design of flexible pipe against singing: testing at multiple scales

    NARCIS (Netherlands)

    Golliard, J.; Lunde, K.; Vijlbrief, O.

    2016-01-01

    Flexible pipes for production of oil and gas typically present a corrugated inner surface. This has been identified as the cause of "singing risers": Flow-Induced Pulsations due to the interaction of sound waves with the shear layers at the small cavities present at each of the multiple

  9. Retrieval practice with short-answer, multiple-choice, and hybrid tests.

    Science.gov (United States)

    Smith, Megan A; Karpicke, Jeffrey D

    2014-01-01

    Retrieval practice improves meaningful learning, and the most frequent way of implementing retrieval practice in classrooms is to have students answer questions. In four experiments (N=372) we investigated the effects of different question formats on learning. Students read educational texts and practised retrieval by answering short-answer, multiple-choice, or hybrid questions. In hybrid conditions students first attempted to recall answers in short-answer format, then identified answers in multiple-choice format. We measured learning 1 week later using a final assessment with two types of questions: those that could be answered by recalling information verbatim from the texts and those that required inferences. Practising retrieval in all format conditions enhanced retention, relative to a study-only control condition, on both verbatim and inference questions. However, there were little or no advantages of answering short-answer or hybrid format questions over multiple-choice questions in three experiments. In Experiment 4, when retrieval success was improved under initial short-answer conditions, there was an advantage of answering short-answer or hybrid questions over multiple-choice questions. The results challenge the simple conclusion that short-answer questions always produce the best learning, due to increased retrieval effort or difficulty, and demonstrate the importance of retrieval success for retrieval-based learning activities.

  10. Testing effect of a drug using multiple nested models for the dose–response

    DEFF Research Database (Denmark)

    Baayen, C.; Hougaard, P.; Pipper, C. B.

    2015-01-01

    of the assumed dose–response model. Bretz et al. (2005, Biometrics 61, 738–748) suggested a combined approach, which selects one or more suitable models from a set of candidate models using a multiple comparison procedure. The method initially requires a priori estimates of any non-linear parameters...

  11. Adaptation of eddy current methods to the multiple problems of reactor testing

    International Nuclear Information System (INIS)

    Stumm, W.

    1975-01-01

    In reactor testing, the eddy current method is mainly used for the testing of surface regions inside the pressure vessel, on welds and joints, and for the testing of thin-walled pipes, e.g. the heat exchanger pipes. (RW/AK) [de

  12. A Sequential Circuit-Based IP Watermarking Algorithm for Multiple Scan Chains in Design-for-Test

    Directory of Open Access Journals (Sweden)

    C. Wu

    2011-06-01

    Full Text Available In Very Large Scale Integrated Circuits (VLSI design, the existing Design-for-Test(DFT based watermarking techniques usually insert watermark through reordering scan cells, which causes large resource overhead, low security and coverage rate of watermark detection. A novel scheme was proposed to watermark multiple scan chains in DFT for solving the problems. The proposed scheme adopts DFT scan test model of VLSI design, and uses a Linear Feedback Shift Register (LFSR for pseudo random test vector generation. All of the test vectors are shifted in scan input for the construction of multiple scan chains with minimum correlation. Specific registers in multiple scan chains will be changed by the watermark circuit for watermarking the design. The watermark can be effectively detected without interference with normal function of the circuit, even after the chip is packaged. The experimental results on several ISCAS benchmarks show that the proposed scheme has lower resource overhead, probability of coincidence and higher coverage rate of watermark detection by comparing with the existing methods.

  13. Functional Magnetic Resonance Imaging with Concurrent Urodynamic Testing Identifies Brain Structures Involved in Micturition Cycle in Patients with Multiple Sclerosis.

    Science.gov (United States)

    Khavari, Rose; Karmonik, Christof; Shy, Michael; Fletcher, Sophie; Boone, Timothy

    2017-02-01

    Neurogenic lower urinary tract dysfunction, which is common in patients with multiple sclerosis, has a significant impact on quality of life. In this study we sought to determine brain activity processes during the micturition cycle in female patients with multiple sclerosis and neurogenic lower urinary tract dysfunction. We report brain activity on functional magnetic resonance imaging and simultaneous urodynamic testing in 23 ambulatory female patients with multiple sclerosis. Individual functional magnetic resonance imaging activation maps at strong desire to void and at initiation of voiding were calculated and averaged at Montreal Neuroimaging Institute. Areas of significant activation were identified in these average maps. Subgroup analysis was performed in patients with elicitable neurogenic detrusor overactivity or detrusor-sphincter dyssynergia. Group analysis of all patients at strong desire to void yielded areas of activation in regions associated with executive function (frontal gyrus), emotional regulation (cingulate gyrus) and motor control (putamen, cerebellum and precuneus). Comparison of the average change in activation between previously reported healthy controls and patients with multiple sclerosis showed predominantly stronger, more focal activation in the former and lower, more diffused activation in the latter. Patients with multiple sclerosis who had demonstrable neurogenic detrusor overactivity and detrusor-sphincter dyssynergia showed a trend toward distinct brain activation at full urge and at initiation of voiding respectively. We successfully studied brain activation during the entire micturition cycle in female patients with neurogenic lower urinary tract dysfunction and multiple sclerosis using a concurrent functional magnetic resonance imaging/urodynamic testing platform. Understanding the central neural processes involved in specific parts of micturition in patients with neurogenic lower urinary tract dysfunction may identify areas

  14. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva

    International Nuclear Information System (INIS)

    Oehninger Gatti, C.; Buzo Del Puerto, R.; Chouza Antelo, C.; Scotti Bianchi, C.; Cibils, D.; Alcantara Pelaez, J.; Gomez, A.; Heuguerot Oliveira, C.

    1994-01-01

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [es

  15. PERMANOVA-S: association test for microbial community composition that accommodates confounders and multiple distances

    OpenAIRE

    Tang, Zheng-Zheng; Chen, Guanhua; Alekseyenko, Alexander V.

    2016-01-01

    Motivation: Recent advances in sequencing technology have made it possible to obtain high-throughput data on the composition of microbial communities and to study the effects of dysbiosis on the human host. Analysis of pairwise intersample distances quantifies the association between the microbiome diversity and covariates of interest (e.g. environmental factors, clinical outcomes, treatment groups). In the design of these analyses, multiple choices for distance metrics are available. Most di...

  16. Specification and testing of Multiplicative Time-Varying GARCH models with applications

    DEFF Research Database (Denmark)

    Amado, Cristina; Teräsvirta, Timo

    2017-01-01

    In this article, we develop a specification technique for building multiplicative time-varying GARCH models of Amado and Teräsvirta (2008, 2013). The variance is decomposed into an unconditional and a conditional component such that the unconditional variance component is allowed to evolve smooth...... is illustrated in practice with two real examples: an empirical application to daily exchange rate returns and another one to daily coffee futures returns....

  17. Assessment of Dermatoglyphics Multiple Intelligence Test (DMIT Reports: Implication to Career Guidance Program Enhancement of Academic Institutions

    Directory of Open Access Journals (Sweden)

    Dr. Maria Luisa A. Valdez

    2014-04-01

    Full Text Available This research aims to assess the reports generated from the Dermatoglyphics Multiple Intelligence Test (DMIT administered by selected DMIT resource companies and consultancy firms in India with the end view of identifying its implication to career guidance program enhancement of academic institutions. This paper employed the descriptive research method which involved the use of documentary analysis, questionnaires and interviews with purposively selected respondents supported by the researchers’ analysis and insights with reference to the content of the data. Findings of this research revealed that the dermatoglyphics, as a scientific discipline, began with the publication of Purkinje’s thesis (1823 and Galton’s classic book, Fingerprints (1892; DMIT is a remarkable offshoot of Howard Gardner’s Theory of Multiple Intelligences which has the following salient features: Overview of the Dermatoglyphics and the Dermatoglyphics Multiple Intelligence Test/Analysis; Personality Assessment; Profile based on Gardner’s Multiple Intelligences and Dunn’s Brain Lateralization Theories; Learning Styles; Competency and Compatibility Profiles; Working Style; Leadership Style; Management Style; Report Interpretation; and Customized Academic and Relationship Advises; the respondents of this study gave their perceptions with reference to the beneficial results of the DMIT; and the foregoing findings have some implications that may be used by academic institutions to enhance their career guidance program.

  18. An Efficient Stepwise Statistical Test to Identify Multiple Linked Human Genetic Variants Associated with Specific Phenotypic Traits.

    Directory of Open Access Journals (Sweden)

    Iksoo Huh

    Full Text Available Recent advances in genotyping methodologies have allowed genome-wide association studies (GWAS to accurately identify genetic variants that associate with common or pathological complex traits. Although most GWAS have focused on associations with single genetic variants, joint identification of multiple genetic variants, and how they interact, is essential for understanding the genetic architecture of complex phenotypic traits. Here, we propose an efficient stepwise method based on the Cochran-Mantel-Haenszel test (for stratified categorical data to identify causal joint multiple genetic variants in GWAS. This method combines the CMH statistic with a stepwise procedure to detect multiple genetic variants associated with specific categorical traits, using a series of associated I × J contingency tables and a null hypothesis of no phenotype association. Through a new stratification scheme based on the sum of minor allele count criteria, we make the method more feasible for GWAS data having sample sizes of several thousands. We also examine the properties of the proposed stepwise method via simulation studies, and show that the stepwise CMH test performs better than other existing methods (e.g., logistic regression and detection of associations by Markov blanket for identifying multiple genetic variants. Finally, we apply the proposed approach to two genomic sequencing datasets to detect linked genetic variants associated with bipolar disorder and obesity, respectively.

  19. Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction.

    Science.gov (United States)

    Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua

    2015-01-01

    A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base.

  20. Evaluating the Psychometric Characteristics of Generated Multiple-Choice Test Items

    Science.gov (United States)

    Gierl, Mark J.; Lai, Hollis; Pugh, Debra; Touchie, Claire; Boulais, André-Philippe; De Champlain, André

    2016-01-01

    Item development is a time- and resource-intensive process. Automatic item generation integrates cognitive modeling with computer technology to systematically generate test items. To date, however, items generated using cognitive modeling procedures have received limited use in operational testing situations. As a result, the psychometric…

  1. Validation of a Standardized Multiple-Choice Multicultural Competence Test: Implications for Training, Assessment, and Practice

    Science.gov (United States)

    Gillem, Angela R.; Bartoli, Eleonora; Bertsch, Kristin N.; McCarthy, Maureen A.; Constant, Kerra; Marrero-Meisky, Sheila; Robbins, Steven J.; Bellamy, Scarlett

    2016-01-01

    The Multicultural Counseling and Psychotherapy Test (MCPT), a measure of multicultural counseling competence (MCC), was validated in 2 phases. In Phase 1, the authors administered 451 test items derived from multicultural guidelines in counseling and psychology to 32 multicultural experts and 30 nonexperts. In Phase 2, the authors administered the…

  2. A Browser-Server-Based Tele-audiology System That Supports Multiple Hearing Test Modalities.

    Science.gov (United States)

    Yao, Jianchu Jason; Yao, Daoyuan; Givens, Gregg

    2015-09-01

    Millions of global citizens suffering from hearing disorders have limited or no access to much needed hearing healthcare. Although tele-audiology presents a solution to alleviate this problem, existing remote hearing diagnosis systems support only pure-tone tests, leaving speech and other test procedures unsolved, due to the lack of software and hardware to enable communication required between audiologists and their remote patients. This article presents a comprehensive remote hearing test system that integrates the two most needed hearing test procedures: a pure-tone audiogram and a speech test. This enhanced system is composed of a Web application server, an embedded smart Internet-Bluetooth(®) (Bluetooth SIG, Kirkland, WA) gateway (or console device), and a Bluetooth-enabled audiometer. Several graphical user interfaces and a relational database are hosted on the application server. The console device has been designed to support the tests and auxiliary communication between the local site and the remote site. The study was conducted at an audiology laboratory. Pure-tone audiogram and speech test results from volunteers tested with this tele-audiology system are comparable with results from the traditional face-to-face approach. This browser-server-based comprehensive tele-audiology offers a flexible platform to expand hearing services to traditionally underserved groups.

  3. Memory-Context Effects of Screen Color in Multiple-Choice and Fill-In Tests

    Science.gov (United States)

    Prestera, Gustavo E.; Clariana, Roy; Peck, Andrew

    2005-01-01

    In this experimental study, 44 undergraduates completed five computer-based instructional lessons and either two multiplechoice tests or two fill-in-the-blank tests. Color-coded borders were displayed during the lesson, adjacent to the screen text and illustrations. In the experimental condition, corresponding border colors were shown at posttest.…

  4. Practice effect in Symbol Digit Modalities Test in multiple sclerosis patients treated with natalizumab

    DEFF Research Database (Denmark)

    Roar Eriksen, Malte; Illes, Zsolt; Sejbaek, Tobias

    2016-01-01

    OBJECTIVES: How practice effect influences cognitive testing measured by monthly Symbol Digit Modalities Test (SDMT) during natalizumab treatment, and what factors confound such effect. METHODS: Eighty patients were examined monthly with SDMT for 26.2±8.4 months. After 26.0±8.1 months, SDMT...... and the rearranged key, respectively. We also explored if natalizumab applied before regular monthly SDMT may influence practice effect and cognition. RESULTS: SDMT performance improved by 1.2 points/test during the first six months and by 0.4 points/test thereafter. Rearranging the symbols of the key after 26.......0±8.1 months returned SDMT scores to baseline indicating a practice effect. Such practice effect was more significant after longer testing period, but was not influenced by gender, age, relapses, disability progression and prior natalizumab treatment. Although the change from baseline to 2.5 years...

  5. Studying different tasks of implicit learning across multiple test sessions conducted on the web

    Directory of Open Access Journals (Sweden)

    Werner eSævland

    2016-06-01

    Full Text Available Implicit learning is usually studied through individual performance on a single task, with the most common tasks being Serial Reaction Time task (SRT; Nissen and Bullemer, 1987, Dynamic System Control task (DSC; (Berry and Broadbent, 1984 and artificial Grammar Learning task (AGL; (Reber, 1967. Few attempts have been made to compare performance across different implicit learning tasks within the same experiment. The current experiment was designed study the relationship between performance on the DSC Sugar factory task (Berry and Broadbent, 1984 and the Alternating Serial Reaction Time task (ASRT; (Howard and Howard, 1997. We also addressed another limitation to traditional implicit learning experiments, namely that implicit learning is usually studied in laboratory settings over a restricted time span lasting for less than an hour (Berry and Broadbent, 1984; Nissen and Bullemer, 1987; Reber, 1967. In everyday situations, implicit learning is assumed to involve a gradual accumulation of knowledge across several learning episodes over a larger time span (Norman and Price, 2012. One way to increase the ecological validity of implicit learning experiments could be to present the learning material repeatedly across shorter experimental sessions (Howard and Howard, 1997; Cleeremans and McClelland, 1991. This can most easily be done by using a web-based setup that participants can access from home. We therefore created an online web-based system for measuring implicit learning that could be administered in either single or multiple sessions. Participants (n = 66 were assigned to either a single-session or a multi-session condition. Learning and the degree of conscious awareness of the learned regularities was compared across condition (single vs. multiple sessions and tasks (DSC vs. ASRT. Results showed that learning on the two tasks was not related. However, participants in the multiple sessions condition did show greater improvements in reaction

  6. A multiple-well method for immunohistochemical testing of many reagents on a single microscopic slide.

    Science.gov (United States)

    McKeever, P E; Letica, L H; Shakui, P; Averill, D R

    1988-09-01

    Multiple wells (M-wells) have been made over tissue sections on single microscopic slides to simultaneously localize binding specificity of many antibodies. More than 20 individual 4-microliter wells over tissue have been applied/slide, representing more than a 5-fold improvement in wells/slide and a 25-fold reduction in reagent volume over previous methods. More than 30 wells/slide have been applied over cellular monolayers. To produce the improvement, previous strategies of placing specimens into wells were changed to instead create wells over the specimen. We took advantage of the hydrophobic properties of paint to surround the wells and to segregate the various different primary antibodies. Segregation was complete on wells alternating with and without primary monoclonal antibody. The procedure accommodates both frozen and paraffin sections, yielding slides which last more than a year. After monoclonal antibody detection, standard histologic stains can be applied as counterstains. M-wells are suitable for localizing binding of multiple reagents or sample unknowns (polyclonal or monoclonal antibodies, hybridoma supernatants, body fluids, lectins) to either tissues or cells. Their small sample volume and large number of sample wells/slide could be particularly useful for early screening of hybridoma supernatants and for titration curves in immunohistochemistry (McKeever PE, Shakui P, Letica LH, Averill DR: J Histochem Cytochem 36:931, 1988).

  7. Results of a diesel multiple unit fuel tank blunt impact test

    Science.gov (United States)

    2017-04-04

    The Federal Railroad Administrations Office of Research and Development is conducting research into passenger locomotive fuel tank crashworthiness. A series of impact tests is being conducted to measure fuel tank deformation under two types of dyn...

  8. Instrumentation, control and data acquisition system with multiple configurations for test in nuclear environment

    Energy Technology Data Exchange (ETDEWEB)

    Monti, Chiara, E-mail: chiara.monti@enea.it; Neri, Carlo; Pollastrone, Fabio

    2015-10-15

    Highlights: • ENEA developed and characterized a first prototype of the In-Vessel Viewing System (IVVS) probe for ITER. • Piezo motor technology to be used in IVVS probe was tested in neutrons, gamma radiations, high temperature, vacuum and high magnetic fields. • A general architecture of the Data Acquisition and Control System (DACS) was defined and then specialized for each test. • The test campaign has validated instrumentation solutions, which can be effectively used in final IVVS implementation or other ITER diagnostics or applications. - Abstract: The In-Vessel Viewing System is a 3D laser scanning system which will be used to inspect the blanket first wall in ITER. To make the IVVS probe design compatible with the harsh environmental conditions present in ITER, a test campaign was performed in 2012–2013 to verify the adequacy of the main components of the IVVS probe. The IVVS components inspected were an optical encoder, passive components and two customized ultrasonic piezoceramic motors that were instrumented with various sensors. A general architecture of the Data Acquisition and Control System (DACS) was defined and then specialized for each test. To be suitable for this test campaign, the DACS had to host various I/O modules and to properly interface the driver of the customized piezo motors, in order to permit the full control of the test and the acquisition of experimental data. This paper presents the instrumentation solutions designed and implemented for different facilities constraints and the related DACS developed in four specialized versions for the described test campaign.

  9. The Benefit of Self-Testing and Interleaving for Synthesizing Concepts across Multiple Physiology Texts

    Science.gov (United States)

    Linderholm, Tracy; Dobson, John; Yarbrough, Mary Beth

    2016-01-01

    A testing-based learning strategy is one that relies on the act of recalling (i.e., testing) information after exposure, and interleaving is a strategy in which the learning materials are presented in a serial order (e.g., "texts 1, 2, 3, 1, 2, 3, 1, 2, 3") versus a blocked order (e.g., "texts 1, 1, 1, 2, 2, 2, 3, 3, 3").…

  10. Bayesian receiver operating characteristic estimation of multiple tests for diagnosis of bovine tuberculosis in Chadian cattle.

    Directory of Open Access Journals (Sweden)

    Borna Müller

    Full Text Available BACKGROUND: Bovine tuberculosis (BTB today primarily affects developing countries. In Africa, the disease is present essentially on the whole continent; however, little accurate information on its distribution and prevalence is available. Also, attempts to evaluate diagnostic tests for BTB in naturally infected cattle are scarce and mostly complicated by the absence of knowledge of the true disease status of the tested animals. However, diagnostic test evaluation in a given setting is a prerequisite for the implementation of local surveillance schemes and control measures. METHODOLOGY/PRINCIPAL FINDINGS: We subjected a slaughterhouse population of 954 Chadian cattle to single intra-dermal comparative cervical tuberculin (SICCT testing and two recently developed fluorescence polarization assays (FPA. Using a Bayesian modeling approach we computed the receiver operating characteristic (ROC curve of each diagnostic test, the true disease prevalence in the sampled population and the disease status of all sampled animals in the absence of knowledge of the true disease status of the sampled animals. In our Chadian setting, SICCT performed better if the cut-off for positive test interpretation was lowered from >4 mm (OIE standard cut-off to >2 mm. Using this cut-off, SICCT showed a sensitivity and specificity of 66% and 89%, respectively. Both FPA tests showed sensitivities below 50% but specificities above 90%. The true disease prevalence was estimated at 8%. Altogether, 11% of the sampled animals showed gross visible tuberculous lesions. However, modeling of the BTB disease status of the sampled animals indicated that 72% of the suspected tuberculosis lesions detected during standard meat inspections were due to other pathogens than Mycobacterium bovis. CONCLUSIONS/SIGNIFICANCE: Our results have important implications for BTB diagnosis in a high incidence sub-Saharan African setting and demonstrate the practicability of our Bayesian approach for

  11. LOCA simulation tests in the RD-12 loop with multiple heat channels

    International Nuclear Information System (INIS)

    Ardron, K.H.; McGee, G.R.; Hawley, E.H.

    1985-11-01

    A series of tests has been performed in the RD-12 loop to study the bahaviour of a CANDU-type, primary heat transport system (PHTS) during the blowdown and injection phases of a loss-of-coolant accident (LOCA). Specifically, the tests were used to investigate flow stagnation and refilling of the core following a LOCA. RD-12 is a pressurized water loop with the basic geometry of a CANDU reactor PHTS, but at approximately 1/125 volume scale. The loop consists of U-tube steam generators, pumps, headers, feeders, and heated channels arranged in the symmetrical figure-of-eight configuration of the CANDU PHTS. In the LOCA simulation tests, the loop contained four horizontal heated channels, each containing a seven-element assembly of indirectly heated, fuel-rod simulators. The channels were nominally identical, and were arranged in parallel pairs between the headers in each half-circuit. Tests were carried out using various restricting orifices to represent pipe breaks of different sizes. The break sizes were specifically chosen such that stagnation conditions in the heated channels would be likely to occur. In some tests, the primary pumps were programmed to run down over a 100-s period to simulate a LOCA with simultaneous loss of pump power. Test results showed that, for certain break sizes, periods of low flow occurred in the channels in one half of the loop, leading to flow stratification and sheath temperature excursions. This report reviews the results of two of the tests, and discusses possible mechanisms that may have led to the low channel flow conditions observed in some cases. Plans for future experiments in the larger scale RD-14 facility are outlined. 5 refs

  12. Use of Pearson's Chi-Square for Testing Equality of Percentile Profiles across Multiple Populations.

    Science.gov (United States)

    Johnson, William D; Beyl, Robbie A; Burton, Jeffrey H; Johnson, Callie M; Romer, Jacob E; Zhang, Lei

    2015-08-01

    In large sample studies where distributions may be skewed and not readily transformed to symmetry, it may be of greater interest to compare different distributions in terms of percentiles rather than means. For example, it may be more informative to compare two or more populations with respect to their within population distributions by testing the hypothesis that their corresponding respective 10 th , 50 th , and 90 th percentiles are equal. As a generalization of the median test, the proposed test statistic is asymptotically distributed as Chi-square with degrees of freedom dependent upon the number of percentiles tested and constraints of the null hypothesis. Results from simulation studies are used to validate the nominal 0.05 significance level under the null hypothesis, and asymptotic power properties that are suitable for testing equality of percentile profiles against selected profile discrepancies for a variety of underlying distributions. A pragmatic example is provided to illustrate the comparison of the percentile profiles for four body mass index distributions.

  13. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. LOFT/L6-7, Loss of Fluid Test, Anticipated Transients with Multiple Failures

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the seventh in the NRC L6 Series of Anticipated Transients experiments. Rapid secondary side induced cooldown was studied. The experiment was conducted on 31 September 1981

  15. Integration and Testing Challenges of Small, Multiple Satellite Missions: Experiences from the Space Technology 5 Project

    Science.gov (United States)

    Sauerwein, Timothy A.; Gostomski, Thomas

    2008-01-01

    The ST5 technology demonstration mission led by GSFC of NASA's New Millennium Program managed by JPL consisted of three micro satellites (approximately 30 kg each) deployed into orbit from the Pegasus XL launch vehicle. In order to meet the launch date schedule of ST5, a different approach was required rather than the standard I&T approach used for single, room-sized satellites. The three spacecraft were designed, integrated, and tested at NASA Goddard Space Flight Center. It was determined that there was insufficient time in the schedule to perform three spacecraft I&T activities in series using standard approaches. The solution was for spacecraft #1 to undergo integration and test first, followed by spacecraft #2 and #3 simultaneously. This simultaneous integration was successful for several reasons. Each spacecraft had a Lead Test Conductor who planned and coordinated their spacecraft through its integration and test activities. One team of engineers and technicians executed the integration of all three spacecraft, learning and gaining knowledge and efficiency as spacecraft #1 integration and testing progressed. They became acutely familiar with the hardware, operation and processes for I&T, thus had the experience and knowledge to safely execute I&T for spacecraft #2 and #3. The integration team was extremely versatile; each member could perform many different activities or work any spacecraft, when needed. ST5 was successfully integrated, tested and shipped to the launch site per the I&T schedule that was planned three years previously. The I&T campaign was completed with ST5's successful launch on March 22, 2006.

  16. Practice effect in Symbol Digit Modalities Test in multiple sclerosis patients treated with natalizumab.

    Science.gov (United States)

    Roar, Malte; Illes, Zsolt; Sejbaek, Tobias

    2016-11-01

    How practice effect influences cognitive testing measured by monthly Symbol Digit Modalities Test (SDMT) during natalizumab treatment, and what factors confound such effect. Eighty patients were examined monthly with SDMT for 26.2±8.4 months. After 26.0±8.1 months, SDMT was also performed with a rearranged key in 59 cases. Results of SDMTs with the rearranged and previous regular key were compared. We examined if gender, age, Extended Disability Status Scale (EDSS), relapses, and disability progression/improvement influence SDMT performed with the regular and the rearranged key, respectively. We also explored if natalizumab applied before regular monthly SDMT may influence practice effect and cognition. SDMT performance improved by 1.2 points/test during the first six months and by 0.4 points/test thereafter. Rearranging the symbols of the key after 26.0±8.1 months returned SDMT scores to baseline indicating a practice effect. Such practice effect was more significant after longer testing period, but was not influenced by gender, age, relapses, disability progression and prior natalizumab treatment. Although the change from baseline to 2.5 years was significant in subgroups with EDSS 0-3, 3.5-5.5 and 6-7.5, this was higher in patients with EDSS 0-3 compared to 6-7.5. Practice effect significantly contributes to continuous improvement in SDMT performance during natalizumab treatment: to test cognition, a change in key is required. Practice effect is less pronounced in patients with advanced disease. Cognition remains stable even in patients with progressive disease during more than 2 years of natalizumab treatment indicated by scores corresponding to baseline after changing the key. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Multiple HEPA filter test methods. Progress report, January--December 1977

    International Nuclear Information System (INIS)

    Schuster, B.; Kyle, T.; Osetek, D.

    1978-09-01

    Tandem high-efficiency particulate air (HEPA) filter efficiency measurements have been successfully performed on a large number of 20,000 CFM installations. The testing procedure relies on the use of a laser intracavity particle spectrometer and a very high-volume thermal dioctyl phthalate aerosol generator designed and constructed specifically for this purpose. For systems that cannot be tested in this fashion, work has been initiated on the generation and detection of a fluorescent self-identifying aerosol to eliminate the background problem. General candidate aerosols and methods to disperse them have been uncovered. Two distinct detection concepts have evolved for the measurement of size and concentration of these particles

  18. I just ran a thousand analyses: benefits of multiple testing in understanding equivocal evidence on gene-environment interactions.

    Directory of Open Access Journals (Sweden)

    Vera E Heininga

    Full Text Available In psychiatric genetics research, the volume of ambivalent findings on gene-environment interactions (G x E is growing at an accelerating pace. In response to the surging suspicions of systematic distortion, we challenge the notion of chance capitalization as a possible contributor. Beyond qualifying multiple testing as a mere methodological issue that, if uncorrected, leads to chance capitalization, we advance towards illustrating the potential benefits of multiple tests in understanding equivocal evidence in genetics literature.We focused on the interaction between the serotonin-transporter-linked promotor region (5-HTTLPR and childhood adversities with regard to depression. After testing 2160 interactions with all relevant measures available within the Dutch population study of adolescents TRAILS, we calculated percentages of significant (p < .05 effects for several subsets of regressions. Using chance capitalization (i.e. overall significance rate of 5% alpha and randomly distributed findings as a competing hypothesis, we expected more significant effects in the subsets of regressions involving: 1 interview-based instead of questionnaire-based measures; 2 abuse instead of milder childhood adversities; and 3 early instead of later adversities. Furthermore, we expected equal significance percentages across 4 male and female subsamples, and 5 various genotypic models of 5-HTTLPR.We found differences in the percentages of significant interactions among the subsets of analyses, including those regarding sex-specific subsamples and genetic modeling, but often in unexpected directions. Overall, the percentage of significant interactions was 7.9% which is only slightly above the 5% that might be expected based on chance.Taken together, multiple testing provides a novel approach to better understand equivocal evidence on G x E, showing that methodological differences across studies are a likely reason for heterogeneity in findings - but chance

  19. A simple test of choice stepping reaction time for assessing fall risk in people with multiple sclerosis.

    Science.gov (United States)

    Tijsma, Mylou; Vister, Eva; Hoang, Phu; Lord, Stephen R

    2017-03-01

    Purpose To determine (a) the discriminant validity for established fall risk factors and (b) the predictive validity for falls of a simple test of choice stepping reaction time (CSRT) in people with multiple sclerosis (MS). Method People with MS (n = 210, 21-74y) performed the CSRT, sensorimotor, balance and neuropsychological tests in a single session. They were then followed up for falls using monthly fall diaries for 6 months. Results The CSRT test had excellent discriminant validity with respect to established fall risk factors. Frequent fallers (≥3 falls) performed significantly worse in the CSRT test than non-frequent fallers (0-2 falls). With the odds of suffering frequent falls increasing 69% with each SD increase in CSRT (OR = 1.69, 95% CI: 1.27-2.26, p = falls in people with MS. This test may prove useful in documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions. Implications for rehabilitation Good choice stepping reaction time (CSRT) is required for maintaining balance. A simple low-tech CSRT test has excellent discriminative and predictive validity in relation to falls in people with MS. This test may prove useful documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions.

  20. Mechanical Waves Conceptual Survey: Its Modification and Conversion to a Standard Multiple-Choice Test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2016-01-01

    In this article we present several modifications of the mechanical waves conceptual survey, the most important test to date that has been designed to evaluate university students' understanding of four main topics in mechanical waves: propagation, superposition, reflection, and standing waves. The most significant changes are (i) modification of…

  1. Comparing Treatment and Control Groups on Multiple Outcomes: Robust Procedures for Testing a Directional Alternative Hypothesis

    Science.gov (United States)

    Lix, Lisa M.; Deering, Kathleen N.; Fouladi, Rachel T.; Manivong, Phongsack

    2009-01-01

    This study considers the problem of testing the difference between treatment and control groups on m [greater than or equal to] 2 measures when it is assumed a priori that the treatment group will perform better than the control group on all measures. Two procedures are investigated that do not rest on the assumptions of covariance homogeneity or…

  2. A non-parametric test for partial monotonicity in multiple regression

    NARCIS (Netherlands)

    van Beek, M.; Daniëls, H.A.M.

    Partial positive (negative) monotonicity in a dataset is the property that an increase in an independent variable, ceteris paribus, generates an increase (decrease) in the dependent variable. A test for partial monotonicity in datasets could (1) increase model performance if monotonicity may be

  3. Relational Aggression and Hostile Attribution Biases: Testing Multiple Statistical Methods and Models

    Science.gov (United States)

    Godleski, Stephanie A.; Ostrov, Jamie M.

    2010-01-01

    The present study used both categorical and dimensional approaches to test the association between relational and physical aggression and hostile intent attributions for both relational and instrumental provocation situations using the National Institute of Child Health and Human Development longitudinal Study of Early Child Care and Youth…

  4. Relationship between Academic Stress and Suicidal Ideation: Testing for Depression as a Mediator Using Multiple Regression

    Science.gov (United States)

    Ang, Rebecca P.; Huan, Vivien S.

    2006-01-01

    Relations among academic stress, depression, and suicidal ideation were examined in 1,108 Asian adolescents 12-18 years old from a secondary school in Singapore. Using Baron and Kenny's [J Pers Soc Psychol 51:1173-1192, 1986] framework, this study tested the prediction that adolescent depression mediated the relationship between academic stress…

  5. Multiple comparisons permutation test for image based data mining in radiotherapy

    NARCIS (Netherlands)

    Chen, Chun; Witte, Marnix; Heemsbergen, Wilma; van Herk, Marcel

    2013-01-01

    : Comparing incidental dose distributions (i.e. images) of patients with different outcomes is a straightforward way to explore dose-response hypotheses in radiotherapy. In this paper, we introduced a permutation test that compares images, such as dose distributions from radiotherapy, while tackling

  6. Now, whose schools are really better (or weaker) than Germany's? A multiple testing approach

    NARCIS (Netherlands)

    Hanck, C.

    Using PIRLS (Progress in International Reading Literacy Study) data, we investigate which countries' schools can be classified as significantly better or weaker than Germany's as regards the reading literacy of primary school children. The 'standard' approach is to conduct separate tests for each

  7. Benefits of Multiple Methods for Evaluating HIV Counseling and Testing Sites in Pennsylvania.

    Science.gov (United States)

    Encandela, John A.; Gehl, Mary Beth; Silvestre, Anthony; Schelzel, George

    1999-01-01

    Examines results from two methods used to evaluate publicly funded human immunodeficiency virus (HIV) counseling and testing in Pennsylvania. Results of written mail surveys of all sites and interviews from a random sample of 30 sites were similar in terms of questions posed and complementary in other ways. (SLD)

  8. The Relative Importance of Low Significance Level and High Power in Multiple Tests of Significance.

    Science.gov (United States)

    Westermann, Rainer; Hager, Willi

    1983-01-01

    Two psychological experiments--Anderson and Shanteau (1970), Berkowitz and LePage (1967)--are reanalyzed to present the problem of the relative importance of low Type 1 error probability and high power when answering a research question by testing several statistical hypotheses. (Author/PN)

  9. Experimental evaluation of emergency operating procedures on multiple steam generator tube rupture in INER integral system test facility

    International Nuclear Information System (INIS)

    Liu, T.J.; Lin, Y.M.; Lee, C.H.; Chang, C.Y.; Hong, W.T.

    1997-01-01

    The multiple steam generator tube rupture (SGTR) scenario in Westinghouse type pressurized water reactor (PWR) has been investigated at the Institute of Nuclear Energy Research (INER) Integral System Test (IIST) facility. This reduced-height and reduced-pressure test facility was designed to simulate the main features of Maanshan nuclear power plant. The SGTR test scenario assumes the double-ended break of one-, two- and six- tubes without other failures. The major operator actions follow the related symptom-oriented Emergency Operating Procedure (EOP) on the reference plant. This study focuses on the investigation of thermal-hydraulics phenomena and the adequacy of associated EOP to limit primary-to-secondary leakage. Through this study, it is found that the adequacy of current EOP in minimizing the radioactivity release demands early substantial operator involvement, especially in the multi-tubes break events. Also, the detailed mechanism of the main thermal-hydraulic phenomena during the SGTR transient are explored. (author)

  10. The Prevalence of Multiple-Choice Testing in Registered Nurse Licensure-Qualifying Nursing Education Programs in New York State.

    Science.gov (United States)

    Birkhead, Susan; Kelman, Glenda; Zittel, Barbara; Jatulis, Linnea

    The aim of this study was to describe nurse educators' use of multiple-choice questions (MCQs) in testing in registered nurse licensure-qualifying nursing education programs in New York State. This study was a descriptive correlational analysis of data obtained from surveying 1,559 nurse educators; 297 educators from 61 institutions responded (response rate [RR] = 19 percent), yielding a final cohort of 200. MCQs were reported to comprise a mean of 81 percent of questions on a typical test. Baccalaureate program respondents were equally likely to use MCQs as associate degree program respondents (p > .05) but were more likely to report using other methods of assessing student achievement to construct course grades (p < .01). Both groups reported little use of alternate format-type questions. Respondent educators reported substantial reliance upon the use of MCQs, corroborating the limited data quantifying the prevalence of use of MCQ tests in licensure-qualifying nursing education programs.

  11. A generalized Grubbs-Beck test statistic for detecting multiple potentially influential low outliers in flood series

    Science.gov (United States)

    Cohn, T.A.; England, J.F.; Berenbrock, C.E.; Mason, R.R.; Stedinger, J.R.; Lamontagne, J.R.

    2013-01-01

    he Grubbs-Beck test is recommended by the federal guidelines for detection of low outliers in flood flow frequency computation in the United States. This paper presents a generalization of the Grubbs-Beck test for normal data (similar to the Rosner (1983) test; see also Spencer and McCuen (1996)) that can provide a consistent standard for identifying multiple potentially influential low flows. In cases where low outliers have been identified, they can be represented as “less-than” values, and a frequency distribution can be developed using censored-data statistical techniques, such as the Expected Moments Algorithm. This approach can improve the fit of the right-hand tail of a frequency distribution and provide protection from lack-of-fit due to unimportant but potentially influential low flows (PILFs) in a flood series, thus making the flood frequency analysis procedure more robust.

  12. Multiplicity distributions of gluon and quark jets and tests of QCD analytic predictions

    Science.gov (United States)

    OPAL Collaboration; Ackerstaff, K.; et al.

    Gluon jets are identified in e+e^- hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The charged particle multiplicity distribution of the gluon jets is presented, and is analyzed for its mean, dispersion, skew, and curtosis values, and for its factorial and cumulant moments. The results are compared to the analogous results found for a sample of light quark (uds) jets, also defined inclusively. We observe differences between the mean, skew and curtosis values of gluon and quark jets, but not between their dispersions. The cumulant moment results are compared to the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observed to provide a much improved description of the data compared to a next-to-leading order calculation without energy conservation. There is agreement between the data and calculations for the ratios of the cumulant moments between gluon and quark jets.

  13. Multiplicity distributions of gluon and quark jets and tests of QCD analytic predictions

    CERN Document Server

    Ackerstaff, K; Allison, J; Altekamp, N; Anderson, K J; Anderson, S; Arcelli, S; Asai, S; Axen, D A; Azuelos, Georges; Ball, A H; Barberio, E; Barlow, R J; Bartoldus, R; Batley, J Richard; Baumann, S; Bechtluft, J; Beeston, C; Behnke, T; Bell, A N; Bell, K W; Bella, G; Bentvelsen, Stanislaus Cornelius Maria; Bethke, Siegfried; Biebel, O; Biguzzi, A; Bird, S D; Blobel, Volker; Bloodworth, Ian J; Bloomer, J E; Bobinski, M; Bock, P; Bonacorsi, D; Boutemeur, M; Bouwens, B T; Braibant, S; Brigliadori, L; Brown, R M; Burckhart, Helfried J; Burgard, C; Bürgin, R; Capiluppi, P; Carnegie, R K; Carter, A A; Carter, J R; Chang, C Y; Charlton, D G; Chrisman, D; Clarke, P E L; Cohen, I; Conboy, J E; Cooke, O C; Cuffiani, M; Dado, S; Dallapiccola, C; Dallavalle, G M; Davis, R; De Jong, S; del Pozo, L A; Desch, Klaus; Dienes, B; Dixit, M S; do Couto e Silva, E; Doucet, M; Duchovni, E; Duckeck, G; Duerdoth, I P; Eatough, D; Edwards, J E G; Estabrooks, P G; Evans, H G; Evans, M; Fabbri, Franco Luigi; Fanti, M; Faust, A A; Fiedler, F; Fierro, M; Fischer, H M; Fleck, I; Folman, R; Fong, D G; Foucher, M; Fürtjes, A; Futyan, D I; Gagnon, P; Gary, J W; Gascon, J; Gascon-Shotkin, S M; Geddes, N I; Geich-Gimbel, C; Geralis, T; Giacomelli, G; Giacomelli, P; Giacomelli, R; Gibson, V; Gibson, W R; Gingrich, D M; Glenzinski, D A; Goldberg, J; Goodrick, M J; Gorn, W; Grandi, C; Gross, E; Grunhaus, Jacob; Gruwé, M; Hajdu, C; Hanson, G G; Hansroul, M; Hapke, M; Hargrove, C K; Hart, P A; Hartmann, C; Hauschild, M; Hawkes, C M; Hawkings, R; Hemingway, Richard J; Herndon, M; Herten, G; Heuer, R D; Hildreth, M D; Hill, J C; Hillier, S J; Hobson, P R; Homer, R James; Honma, A K; Horváth, D; Hossain, K R; Howard, R; Hüntemeyer, P; Hutchcroft, D E; Igo-Kemenes, P; Imrie, D C; Ingram, M R; Ishii, K; Jawahery, A; Jeffreys, P W; Jeremie, H; Jimack, Martin Paul; Joly, A; Jones, C R; Jones, G; Jones, M; Jost, U; Jovanovic, P; Junk, T R; Karlen, D A; Kartvelishvili, V G; Kawagoe, K; Kawamoto, T; Kayal, P I; Keeler, Richard K; Kellogg, R G; Kennedy, B W; Kirk, J; Klier, A; Kluth, S; Kobayashi, T; Kobel, M; Koetke, D S; Kokott, T P; Kolrep, M; Komamiya, S; Kress, T; Krieger, P; Von Krogh, J; Kyberd, P; Lafferty, G D; Lahmann, R; Lai, W P; Lanske, D; Lauber, J; Lautenschlager, S R; Layter, J G; Lazic, D; Lee, A M; Lefebvre, E; Lellouch, Daniel; Letts, J; Levinson, L; Lloyd, S L; Loebinger, F K; Long, G D; Losty, Michael J; Ludwig, J; Macchiolo, A; MacPherson, A L; Mannelli, M; Marcellini, S; Markus, C; Martin, A J; Martin, J P; Martínez, G; Mashimo, T; Mättig, P; McDonald, W J; McKenna, J A; McKigney, E A; McMahon, T J; McPherson, R A; Meijers, F; Menke, S; Merritt, F S; Mes, H; Meyer, J; Michelini, Aldo; Mikenberg, G; Miller, D J; Mincer, A; Mir, R; Mohr, W; Montanari, A; Mori, T; Morii, M; Müller, U; Mihara, S; Nagai, K; Nakamura, I; Neal, H A; Nellen, B; Nisius, R; O'Neale, S W; Oakham, F G; Odorici, F; Ögren, H O; Oh, A; Oldershaw, N J; Oreglia, M J; Orito, S; Pálinkás, J; Pásztor, G; Pater, J R; Patrick, G N; Patt, J; Pearce, M J; Pérez-Ochoa, R; Petzold, S; Pfeifenschneider, P; Pilcher, J E; Pinfold, J L; Plane, D E; Poffenberger, P R; Poli, B; Posthaus, A; Rees, D L; Rigby, D; Robertson, S; Robins, S A; Rodning, N L; Roney, J M; Rooke, A M; Ros, E; Rossi, A M; Routenburg, P; Rozen, Y; Runge, K; Runólfsson, O; Ruppel, U; Rust, D R; Rylko, R; Sachs, K; Saeki, T; Sarkisyan-Grinbaum, E; Sbarra, C; Schaile, A D; Schaile, O; Scharf, F; Scharff-Hansen, P; Schenk, P; Schieck, J; Schleper, P; Schmitt, B; Schmitt, S; Schöning, A; Schröder, M; Schultz-Coulon, H C; Schumacher, M; Schwick, C; Scott, W G; Shears, T G; Shen, B C; Shepherd-Themistocleous, C H; Sherwood, P; Siroli, G P; Sittler, A; Skillman, A; Skuja, A; Smith, A M; Snow, G A; Sobie, Randall J; Söldner-Rembold, S; Springer, R W; Sproston, M; Stephens, K; Steuerer, J; Stockhausen, B; Stoll, K; Strom, D; Szymanski, P; Tafirout, R; Talbot, S D; Tanaka, S; Taras, P; Tarem, S; Teuscher, R; Thiergen, M; Thomson, M A; Von Törne, E; Towers, S; Trigger, I; Trócsányi, Z L; Tsur, E; Turcot, A S; Turner-Watson, M F; Utzat, P; Van Kooten, R; Verzocchi, M; Vikas, P; Vokurka, E H; Voss, H; Wäckerle, F; Wagner, A; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Wells, P S; Wermes, N; White, J S; Wilkens, B; Wilson, G W; Wilson, J A; Wolf, G; Wyatt, T R; Yamashita, S; Yekutieli, G; Zacek, V; Zer-Zion, D

    1999-01-01

    Gluon jets are identified in e+e- hadronic annihilation events by tagging two quark jets in the same hemisphere of an event. The gluon jet is defined inclusively as all the particles in the opposite hemisphere. Gluon jets defined in this manner have a close correspondence to gluon jets as they are defined for analytic calculations, and are almost independent of a jet finding algorithm. The charged particle multiplicity distribution of the gluon jets is presented, and is analyzed for its mean, dispersion, skew, and curtosis values, and for its factorial and cumulant moments. The results are compared to the analogous results found for a sample of light quark (uds) jets, also defined inclusively. We observe differences between the mean, skew and curtosis values of gluon and quark jets, but not between their dispersions. The cumulant moment results are compared to the predictions of QCD analytic calculations. A calculation which includes next-to-next-to-leading order corrections and energy conservation is observe...

  14. Perceiving a calling, living a calling, and job satisfaction: testing a moderated, multiple mediator model.

    Science.gov (United States)

    Duffy, Ryan D; Bott, Elizabeth M; Allan, Blake A; Torrey, Carrie L; Dik, Bryan J

    2012-01-01

    The current study examined the relation between perceiving a calling, living a calling, and job satisfaction among a diverse group of employed adults who completed an online survey (N = 201). Perceiving a calling and living a calling were positively correlated with career commitment, work meaning, and job satisfaction. Living a calling moderated the relations of perceiving a calling with career commitment and work meaning, such that these relations were more robust for those with a stronger sense they were living their calling. Additionally, a moderated, multiple mediator model was run to examine the mediating role of career commitment and work meaning in the relation of perceiving a calling and job satisfaction, while accounting for the moderating role of living a calling. Results indicated that work meaning and career commitment fully mediated the relation between perceiving a calling and job satisfaction. However, the indirect effects of work meaning and career commitment were only significant for individuals with high levels of living a calling, indicating the importance of living a calling in the link between perceiving a calling and job satisfaction. Implications for research and practice are discussed. (c) 2012 APA, all rights reserved.

  15. Chronic Pain in Multiple Sclerosis Patients: Utility of Sensory Quantitative Testing in Patients with Fibromyalgia Comorbidity.

    Science.gov (United States)

    Pompa, Alessandra; Clemenzi, Allessandro; Troisi, Elio; Pace, Luca; Casillo, Paolo; Catani, Sheila; Grasso, Maria Grazia

    2015-01-01

    Lower thermal and discomfort thresholds may predispose multiple sclerosis (MS) patients to chronic pain, but a possible effect of fibromyalgia (FM) comorbidity has never been investigated. Aims were to investigate the thermal and discomfort thresholds in the evaluation of pain intensity between MS patients with FM (PFM+) and MS patients with pain not associated to FM (PFM-). One hundred thirty three MS patients were investigated for chronic pain. FM was assessed according to the 1990 ACR diagnostic criteria. An algometer was used to measure the thresholds in the patients and 60 matched healthy subjects. Chronic pain was present in 88 (66.2%) patients; 12 (13.6%) had neuropathic pain, 22 (17.3%) were PFM+ and 65 (48.9%) PFM-. PFM+ were predominantly female (p = 0.03) and had a greater EDSS (p = 0.01) than NoP; no other significant differences emerged than PFM-. The thresholds were lower in MS patients than controls (p < 0.01), mainly in the PFM+. FM severity influenced the thermal threshold (p < 0.001), while the female gender influenced the discomfort threshold (p < 0.001). Thermal and discomfort thresholds were lower in patients than controls and were the lowest in PFM+. Their more severely impaired thermal threshold supports a neurophysiological basis of such association. © 2015 S. Karger AG, Basel.

  16. Deconstructing the symbol digit modalities test in multiple sclerosis: The role of memory.

    Science.gov (United States)

    Patel, Viral P; Walker, Lisa A S; Feinstein, Anthony

    2017-10-01

    The Symbol Digit Modalities Test (SDMT) is a sensitive measure of impaired cognition in people with MS. While the SDMT is primarily considered a test of information processing speed, other components such as visual scanning and oral-motor ability have also been linked to performance. The objective of this study was to determine the role of memory in the performance of the SDMT. Two version of a modified computerized SDMT (c-SDMT) were employed, a fixed and a variable. For each group 50 MS and 33 healthy control (HC) participants were recruited. In the fixed c-SDMT, the symbol-digit code is kept constant for the entire test whereas in the variable version, it changes eight times. Unlike the traditional SDMT which records the correct number of responses, the c-SDMT presented here measures the mean response time (in seconds) for the eight trials. MS participants were slower than HC on the fixed (p < 0.001) and variable (p = 0.005) c-SDMT. Trend analysis showed performance improvement on the fixed, but not on the variable c-SDMT in both MS and HC groups. Furthermore, immediate visual memory recall was associated with the fixed (β = -0.299, p = 0.017), but not variable (B = -0.057, p = 0.260) c-SDMT. Immediate verbal memory was not associated with either versions of the c-SDMT. Given that the fixed and variable c-SDMTs are identical in every way apart from the fixity of the code, the ability of participants to speed up responses over the course of the fixed version only points to the contribution of incidental visual memory in test performance. Copyright © 2017. Published by Elsevier B.V.

  17. Multiple group radiator and hybrid test heads, possibilities of combining the array technique

    International Nuclear Information System (INIS)

    Wuestenberg, H.

    1993-01-01

    This article is intended to show the important considerations, which led to the development of the multichannel group radiator technique. Trends in development and the advantages and disadvantages of the different possibilities are introduced, against the background of experience now available for these configurative variants of ultrasonic test heads. For this reason, a series of experiences and arguments is reported, from the point of view of the developer of the multi-channel group radiator technique. (orig./HP) [de

  18. Optimization and maintenance tests considering multiple failure modes, aging and imperfect maintenance

    International Nuclear Information System (INIS)

    Martorell, S.; Marton, I.; Sanchez, A.; Carlos, S.

    2014-01-01

    The paper focuses on the optimization of the test and maintenance intervals under the criteria of unavailability or cost including the effect of the aging of the components and models of imperfect maintenance. The results obtained in the case of application, which focuses on a system of safety of a nuclear power station, show differences, mainly in the outage when you consider the aging. (Author)

  19. New modelling of transient well test and rate decline analysis for a horizontal well in a multiple-zone reservoir

    International Nuclear Information System (INIS)

    Nie, Ren-Shi; Guo, Jian-Chun; Jia, Yong-Lu; Zhu, Shui-Qiao; Rao, Zheng; Zhang, Chun-Guang

    2011-01-01

    The no-type curve with negative skin of a horizontal well has been found in the current research. Negative skin is very significant to transient well test and rate decline analysis. This paper first presents the negative skin problem where the type curves with negative skin of a horizontal well are oscillatory. In order to solve the problem, we propose a new model of transient well test and rate decline analysis for a horizontal well in a multiple-zone composite reservoir. A new dimensionless definition of r D is introduced in the dimensionless mathematical modelling under different boundaries. The model is solved using the Laplace transform and separation of variables techniques. In Laplace space, the solutions for both constant rate production and constant wellbore pressure production are expressed in a unified formula. We provide graphs and thorough analysis of the new standard type curves for both well test and rate decline analysis; the characteristics of type curves are the reflections of horizontal well production in a multiple-zone reservoir. An important contribution of our paper is that our model removed the oscillation in type curves and thus solved the negative skin problem. We also show that the characteristics of type curves depend heavily on the properties of different zones, skin factor, well length, formation thickness, etc. Our research can be applied to a real case study

  20. A general equation to obtain multiple cut-off scores on a test from multinomial logistic regression.

    Science.gov (United States)

    Bersabé, Rosa; Rivas, Teresa

    2010-05-01

    The authors derive a general equation to compute multiple cut-offs on a total test score in order to classify individuals into more than two ordinal categories. The equation is derived from the multinomial logistic regression (MLR) model, which is an extension of the binary logistic regression (BLR) model to accommodate polytomous outcome variables. From this analytical procedure, cut-off scores are established at the test score (the predictor variable) at which an individual is as likely to be in category j as in category j+1 of an ordinal outcome variable. The application of the complete procedure is illustrated by an example with data from an actual study on eating disorders. In this example, two cut-off scores on the Eating Attitudes Test (EAT-26) scores are obtained in order to classify individuals into three ordinal categories: asymptomatic, symptomatic and eating disorder. Diagnoses were made from the responses to a self-report (Q-EDD) that operationalises DSM-IV criteria for eating disorders. Alternatives to the MLR model to set multiple cut-off scores are discussed.

  1. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  2. Testing For The Linearity of Responses To Multiple Anthropogenic Climate Forcings

    Science.gov (United States)

    Forest, C. E.; Stone, P. H.; Sokolov, A. P.

    To test whether climate forcings are additive, we compare climate model simulations in which anthropogenic forcings are applied individually and in combination. Tests are performed with different values for climate system properties (climate sensitivity and rate of heat uptake by the deep ocean) as well as for different strengths of the net aerosol forcing, thereby testing for the dependence of linearity on these properties. The MIT 2D Land-Ocean Climate Model used in this study consists of a zonally aver- aged statistical-dynamical atmospheric model coupled to a mixed-layer Q-flux ocean model, with heat anomalies diffused into the deep ocean. Following our previous stud- ies, the anthropogenic forcings are the changes in concentrations of greenhouse gases (1860-1995), sulfate aerosol (1860-1995), and stratospheric and tropospheric ozone (1979-1995). The sulfate aerosol forcing is applied as a surface albedo change. For an aerosol forcing of -1.0 W/m2 and an effective ocean diffusitivity of 2.5 cm2/s, the nonlinearity of the response of global-mean surface temperatures to the combined forcing shows a strong dependence on climate sensitivity. The fractional change in decadal averages ([(TG + TS + TO) - TGSO]/TGSO) for the 1986-1995 period compared to pre-industrial times are 0.43, 0.90, and 1.08 with climate sensitiv- ities of 3.0, 4.5, and 6.2 C, respectively. The values of TGSO for these three cases o are 0.52, 0.62, and 0.76 C. The dependence of linearity on climate system properties, o the role of climate system feedbacks, and the implications for the detection of climate system's response to individual forcings will be presented. Details of the model and forcings can be found at http://web.mit.edu/globalchange/www/.

  3. Global testing under sparse alternatives: ANOVA, multiple comparisons and the higher criticism

    OpenAIRE

    Arias-Castro, Ery; Candès, Emmanuel J.; Plan, Yaniv

    2011-01-01

    Testing for the significance of a subset of regression coefficients in a linear model, a staple of statistical analysis, goes back at least to the work of Fisher who introduced the analysis of variance (ANOVA). We study this problem under the assumption that the coefficient vector is sparse, a common situation in modern high-dimensional settings. Suppose we have $p$ covariates and that under the alternative, the response only depends upon the order of $p^{1-\\alpha}$ of those, $0\\le\\alpha\\le1$...

  4. To Show or Not to Show: The Effects of Item Stems and Answer Options on Performance on a Multiple-Choice Listening Comprehension Test

    Science.gov (United States)

    Yanagawa, Kozo; Green, Anthony

    2008-01-01

    The purpose of this study is to examine whether the choice between three multiple-choice listening comprehension test formats results in any difference in listening comprehension test performance. The three formats entail (a) allowing test takers to preview both the question stem and answer options prior to listening; (b) allowing test takers to…

  5. Performance of Men and Women on Multiple-Choice and Constructed-Response Tests for Beginning Teachers. Research Report. ETS RR-04-48

    Science.gov (United States)

    Livingston, Samuel A.; Rupp, Stacie L.

    2004-01-01

    Some previous research results imply that women tend to perform better, relative to men, on constructed-response (CR) tests than on multiple-choice (MC) tests in the same subjects. An analysis of data from several tests used in the licensing of beginning teachers supported this hypothesis, to varying degrees, in most of the tests investigated. The…

  6. A test of multiple correlation temporal window characteristic of non-Markov processes

    Science.gov (United States)

    Arecchi, F. T.; Farini, A.; Megna, N.

    2016-03-01

    We introduce a sensitive test of memory effects in successive events. The test consists of a combination K of binary correlations at successive times. K decays monotonically from K = 1 for uncorrelated events as a Markov process. For a monotonic memory fading, K1 temporal window in cognitive tasks consisting of the visual identification of the front face of the Necker cube after a previous presentation of the same. We speculate that memory effects provide a temporal window with K>1 and this experiment could be a possible first step towards a better comprehension of this phenomenon. The K>1 behaviour is maximal at an inter-measurement time τ around 2s with inter-subject differences. The K>1 persists over a time window of 1s around τ; outside this window the K1 window in pairs of successive perceptions suggests that, at variance with single visual stimuli eliciting a suitable response, a pair of stimuli shortly separated in time displays mutual correlations.

  7. Integrating prior knowledge in multiple testing under dependence with applications to detecting differential DNA methylation.

    Science.gov (United States)

    Kuan, Pei Fen; Chiang, Derek Y

    2012-09-01

    DNA methylation has emerged as an important hallmark of epigenetics. Numerous platforms including tiling arrays and next generation sequencing, and experimental protocols are available for profiling DNA methylation. Similar to other tiling array data, DNA methylation data shares the characteristics of inherent correlation structure among nearby probes. However, unlike gene expression or protein DNA binding data, the varying CpG density which gives rise to CpG island, shore and shelf definition provides exogenous information in detecting differential methylation. This article aims to introduce a robust testing and probe ranking procedure based on a nonhomogeneous hidden Markov model that incorporates the above-mentioned features for detecting differential methylation. We revisit the seminal work of Sun and Cai (2009, Journal of the Royal Statistical Society: Series B (Statistical Methodology)71, 393-424) and propose modeling the nonnull using a nonparametric symmetric distribution in two-sided hypothesis testing. We show that this model improves probe ranking and is robust to model misspecification based on extensive simulation studies. We further illustrate that our proposed framework achieves good operating characteristics as compared to commonly used methods in real DNA methylation data that aims to detect differential methylation sites. © 2012, The International Biometric Society.

  8. The Symbol Digit Modalities Test is an effective cognitive screen in pediatric onset multiple sclerosis (MS).

    Science.gov (United States)

    Charvet, Leigh E; Beekman, Rachel; Amadiume, Nneka; Belman, Anita L; Krupp, Lauren B

    2014-06-15

    To evaluate the Symbol Digit Modalities Test (SDMT) as a tool for identifying pediatric-onset MS patients at risk for cognitive impairment. The SDMT is a brief measure of cognitive processing speed that is often used in adult MS patients. Approximately one-third of pediatric-onset MS patients have cognitive impairment and there is a need for an effective screening instrument. Seventy (70) consecutive outpatients with pediatric-onset MS underwent clinical evaluations including the SDMT and were compared to those with other pediatric neurological diagnoses (OND, n=40) and healthy controls (HC, n=32). A subset of the MS group and all healthy controls completed neuropsychological evaluation within one year of SDMT administration. The MS group performed worse on the SDMT compared to the HC group (p=0.02). Thirty-seven percent (37%) of the MS, 20% of the OND, and 9% of HC groups scored in the impaired range. For MS participants who underwent neuropsychological testing (n=31), the SDMT showed 77% sensitivity and 81% specificity for detecting neuropsychological impairment when administered within one year and reached 100% sensitivity when the interval was under two months (n=17). Overall, older age and increased disability predicted poorer SDMT performance (age r=-0.26, p=0.03) and the Expanded Disability Status Scale score or EDSS (r=-0.47, pMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A nonparametric empirical Bayes framework for large-scale multiple testing.

    Science.gov (United States)

    Martin, Ryan; Tokdar, Surya T

    2012-07-01

    We propose a flexible and identifiable version of the 2-groups model, motivated by hierarchical Bayes considerations, that features an empirical null and a semiparametric mixture model for the nonnull cases. We use a computationally efficient predictive recursion (PR) marginal likelihood procedure to estimate the model parameters, even the nonparametric mixing distribution. This leads to a nonparametric empirical Bayes testing procedure, which we call PRtest, based on thresholding the estimated local false discovery rates. Simulations and real data examples demonstrate that, compared to existing approaches, PRtest's careful handling of the nonnull density can give a much better fit in the tails of the mixture distribution which, in turn, can lead to more realistic conclusions.

  10. Comparison of Force and Moment Coefficients for the Same Test Article in Multiple Wind Tunnels

    Science.gov (United States)

    Deloach, Richard

    2013-01-01

    This paper compares the results of force and moment measurements made on the same test article and with the same balance in three transonic wind tunnels. Comparisons are made for the same combination of Reynolds number, Mach number, sideslip angle, control surface configuration, and angle of attack range. Between-tunnel force and moment differences are quantified. An analysis of variance was performed at four unique sites in the design space to assess the statistical significance of between-tunnel variation and any interaction with angle of attack. Tunnel to tunnel differences too large to attribute to random error were detected were observed for all forces and moments. In some cases these differences were independent of angle of attack and in other cases they changed with angle of attack.

  11. Integrating Multiple Microarray Data for Cancer Pathway Analysis Using Bootstrapping K-S Test

    Directory of Open Access Journals (Sweden)

    Bing Han

    2009-01-01

    Full Text Available Previous applications of microarray technology for cancer research have mostly focused on identifying genes that are differentially expressed between a particular cancer and normal cells. In a biological system, genes perform different molecular functions and regulate various biological processes via interactions with other genes thus forming a variety of complex networks. Therefore, it is critical to understand the relationship (e.g., interactions between genes across different types of cancer in order to gain insights into the molecular mechanisms of cancer. Here we propose an integrative method based on the bootstrapping Kolmogorov-Smirnov test and a large set of microarray data produced with various types of cancer to discover common molecular changes in cells from normal state to cancerous state. We evaluate our method using three key pathways related to cancer and demonstrate that it is capable of finding meaningful alterations in gene relations.

  12. Diagnostic value of stool DNA testing for multiple markers of colorectal cancer and advanced adenoma: a meta-analysis.

    Science.gov (United States)

    Yang, Hua; Xia, Bing-Qing; Jiang, Bo; Wang, Guozhen; Yang, Yi-Peng; Chen, Hao; Li, Bing-Sheng; Xu, An-Gao; Huang, Yun-Bo; Wang, Xin-Ying

    2013-08-01

    The diagnostic value of stool DNA (sDNA) testing for colorectal neoplasms remains controversial. To compensate for the lack of large-scale unbiased population studies, a meta-analysis was performed to evaluate the diagnostic value of sDNA testing for multiple markers of colorectal cancer (CRC) and advanced adenoma. The PubMed, Science Direct, Biosis Review, Cochrane Library and Embase databases were systematically searched in January 2012 without time restriction. Meta-analysis was performed using a random-effects model using sensitivity, specificity, diagnostic OR (DOR), summary ROC curves, area under the curve (AUC), and 95% CIs as effect measures. Heterogeneity was measured using the χ(2) test and Q statistic; subgroup analysis was also conducted. A total of 20 studies comprising 5876 individuals were eligible. There was no heterogeneity for CRC, but adenoma and advanced adenoma harboured considerable heterogeneity influenced by risk classification and various detection markers. Stratification analysis according to risk classification showed that multiple markers had a high DOR for the high-risk subgroups of both CRC (sensitivity 0.759 [95% CI 0.711 to 0.804]; specificity 0.883 [95% CI 0.846 to 0.913]; AUC 0.906) and advanced adenoma (sensitivity 0.683 [95% CI 0.584 to 0.771]; specificity 0.918 [95% CI 0.866 to 0.954]; AUC 0.946) but not for the average-risk subgroups of either. In the methylation subgroup, sDNA testing had significantly higher DOR for CRC (sensitivity 0.753 [95% CI 0.685 to 0.812]; specificity 0.913 [95% CI 0.860 to 0.950]; AUC 0.918) and advanced adenoma (sensitivity 0.623 [95% CI 0.527 to 0.712]; specificity 0.926 [95% CI 0.882 to 0.958]; AUC 0.910) compared with the mutation subgroup. There was no significant heterogeneity among studies for subgroup analysis. sDNA testing for multiple markers had strong diagnostic significance for CRC and advanced adenoma in high-risk subjects. Methylation makers had more diagnostic value than mutation

  13. Comparison between three option, four option and five option multiple choice question tests for quality parameters: A randomized study.

    Science.gov (United States)

    Vegada, Bhavisha; Shukla, Apexa; Khilnani, Ajeetkumar; Charan, Jaykaran; Desai, Chetna

    2016-01-01

    Most of the academic teachers use four or five options per item of multiple choice question (MCQ) test as formative and summative assessment. Optimal number of options in MCQ item is a matter of considerable debate among academic teachers of various educational fields. There is a scarcity of the published literature regarding the optimum number of option in each item of MCQ in the field of medical education. To compare three options, four options, and five options MCQs test for the quality parameters - reliability, validity, item analysis, distracter analysis, and time analysis. Participants were 3 rd semester M.B.B.S. students. Students were divided randomly into three groups. Each group was given one set of MCQ test out of three options, four options, and five option randomly. Following the marking of the multiple choice tests, the participants' option selections were analyzed and comparisons were conducted of the mean marks, mean time, validity, reliability and facility value, discrimination index, point biserial value, distracter analysis of three different option formats. Students score more ( P = 0.000) and took less time ( P = 0.009) for the completion of three options as compared to four options and five options groups. Facility value was more ( P = 0.004) in three options group as compared to four and five options groups. There was no significant difference between three groups for the validity, reliability, and item discrimination. Nonfunctioning distracters were more in the four and five options group as compared to three option group. Assessment based on three option MCQs is can be preferred over four option and five option MCQs.

  14. 'Multiple-test' approach to the laboratory diagnosis of tuberculosis -perception of medical doctors from Ujjain, India.

    Science.gov (United States)

    Purohit, Manju Raj; Sharma, Megha; Rosales-Klintz, Senia; Lundborg, Cecilia Stålsby

    2015-08-11

    Delay in diagnosis is one of the most important factors for the control of tuberculosis (TB) in endemic countries like India. As laboratory diagnosis is the mainstay for identification of active disease, we aim to explore and understand the opinions of medical doctors about the laboratory diagnosis of TB in Ujjain, India. Sixteen qualified specialist medical doctors from Ujjain were purposefully selected for the study. Individual interviews with the doctors (13 men and 3 women), were conducted. As one interview could not be completed, data from 15 interviews were analyzed using manifest and latent content analysis. Based on perception of the doctors, the theme; 'challenges and need for the laboratory diagnosis of TB' emerged from the following subthemes: (i) Relationship between basic element of the TB diseases process such as 'Symptoms prior to diagnoses' and 'Clinical characteristics of TB', which were not specific enough to diagnose TB (ii) The prevailing conditions such as lack of explicit diagnostic tools, lead to the doctors using the 'multiple tests' or 'empiric treatment' approach (iii) The doctors proposed that there is a need for access to a rapid, single and simple diagnostic test, and a need for awareness and knowledge of the practitioners regarding specific TB investigations, and early referral to improve the situation at resource-limited settings. The medical specialists use a 'multiple test' or 'empiric treatment' approach to diagnose TB. According to the participants, there is a low dependence and uptake of the available laboratory TB investigations by medical practitioners. There is an urgent need to have a specific, simple and reliable test, and a protocol, to improve diagnosis of TB and to prevent development of resistant TB.

  15. The valuation of environmental goods in Norway: A contingent valuation study with multiple bias testing

    Energy Technology Data Exchange (ETDEWEB)

    Strand, J.; Taraldset, A.

    1991-01-01

    We report on a study of contingent valuation of reduction in air pollution, and of a broader set of six environmental issues, among a population sample in Oslo. We derive an estimate of the extent of upward bias due to mental accouting'' in the expressed valuation of the air pollution issue, in two steps: (1) by comparing valuation of air pollution alone, with the same when the other issues at the same time are to be dealt with; and (2) by deriving the implicit valuation of the air pollution issue from the ranking of issues, and total valuation of all six issues. We find that expressed valuation of air pollution reductions are 3-4 times as high as the true'' values, and argue that this discrepancy is mainly due to mental account biases. We also test for strategic, starting point, information and interviewer biases, which are all present and, with the exception of the information bias, all in the expected directions. 9 refs., 4 tabs.

  16. The valuation of environmental goods in Norway: A contingent valuation study with multiple bias testing

    Energy Technology Data Exchange (ETDEWEB)

    Strand, J.; Taraldset, A.

    1991-12-31

    We report on a study of contingent valuation of reduction in air pollution, and of a broader set of six environmental issues, among a population sample in Oslo. We derive an estimate of the extent of upward bias due to ``mental accouting`` in the expressed valuation of the air pollution issue, in two steps: (1) by comparing valuation of air pollution alone, with the same when the other issues at the same time are to be dealt with; and (2) by deriving the implicit valuation of the air pollution issue from the ranking of issues, and total valuation of all six issues. We find that expressed valuation of air pollution reductions are 3-4 times as high as the ``true`` values, and argue that this discrepancy is mainly due to mental account biases. We also test for strategic, starting point, information and interviewer biases, which are all present and, with the exception of the information bias, all in the expected directions. 9 refs., 4 tabs.

  17. Multiple HEPA filter test methods, July 1, 1974--March 31, 1975

    International Nuclear Information System (INIS)

    Schuster, B.G.; Osetek, D.J.

    1975-08-01

    A laboratory apparatus has been constructed for testing two HEPA filters in a series configuration. The apparatus consists of an instrumented wind tunnel in which the HEPA filters are mounted, and an auxiliary wind tunnel for obtaining diluted samples of the challenge aerosol upstream of the first filter. Measurements performed with a single particle aerosol spectrometer demonstrate the capability for measuring overall protection factors of greater than 2.5 x 10 8 . The decay of penetration as a function of time in individual HEPA filters indicates no preferential size discrimination in the range of 0.1 μm to 1.0 μm; nor is there a preferential size discrimination of penetration in this same range. A theoretical feasibility study has been performed on the use of an inhomogeneous electric field/induced aerosol electric dipole interaction for potential use as an air cleaning mechanism. Numerical evaluation of a coaxial cylinder geometry indicates that the method is feasible for collection of particles down to 0.1 μm under typical airflow velocity conditions. Small modifications in the geometry may be incorporated to create an instrument capable of measuring particle size. Geometries other than coaxial cylinders are also under investigation

  18. Testing an Adapted Modified Delphi Method: Synthesizing Multiple Stakeholder Ratings of Health Care Service Effectiveness.

    Science.gov (United States)

    Escaron, Anne L; Chang Weir, Rosy; Stanton, Petra; Vangala, Sitaram; Grogan, Tristan R; Clarke, Robin M

    2016-03-01

    The Affordable Care Act incentivizes health systems for better meeting patient needs, but often guidance about patient preferences for particular health services is limited. All too often vulnerable patient populations are excluded from these decision-making settings. A community-based participatory approach harnesses the in-depth knowledge of those experiencing barriers to health care. We made three modifications to the RAND-UCLA appropriateness method, a modified Delphi approach, involving patients, adding an advisory council group to characterize existing knowledge in this little studied area, and using effectiveness rather than "appropriateness" as the basis for rating. As a proof of concept, we tested this method by examining the broadly delivered but understudied nonmedical services that community health centers provide. This method created discrete, new knowledge about these services by defining 6 categories and 112 unique services and by prioritizing among these services based on effectiveness using a 9-point scale. Consistent with the appropriateness method, we found statistical convergence of ratings among the panelists. Challenges include time commitment and adherence to a clear definition of effectiveness of services. This diverse stakeholder engagement method efficiently addresses gaps in knowledge about the effectiveness of health care services to inform population health management. © 2015 Society for Public Health Education.

  19. LEGO plot for simultaneous application of multiple quality requirements during trueness verification of quantitative laboratory tests.

    Science.gov (United States)

    Park, Hae-il; Chae, Hyojin; Kim, Myungshin; Lee, Jehoon; Kim, Yonggoo

    2014-03-01

    We developed a two-dimensional plot for viewing trueness that takes into account potential shift and variable quality requirements to verify trueness using certified reference material (CRM). Glucose, total cholesterol (TC), and creatinine levels were determined by two kinds of assay in two levels of a CRM. Available quality requirements were collected, codified, and sorted in an ascending order in the plot's header row. Centering on the mean of measured values from CRM, the "mean ± US CLIA '88 allowable total error" was located in the header of the leftmost and rightmost columns. Twenty points were created in intervening columns as potential shifts. Uncertainties were calculated according to regression between certified values and uncertainties of CRM, and positioned in the corresponding columns. Cells were assigned different colors where column and row intersected based on comparison of the 95% confidence interval of the percentage bias with each quality requirement. A glucose assay failed to meet the highest quality criteria, for which shift of +0.13-0.14 mmol/l was required. A TC assay met the quality requirement and a shift of ±0.03 mmol/l was tolerable. A creatinine assay also met the quality requirement but any shift was not tolerable. The plot provides a systematic view of the trueness of quantitative laboratory tests. © 2014 Wiley Periodicals, Inc.

  20. Testing sequential extraction methods for the analysis of multiple stable isotope systems from a bone sample

    Science.gov (United States)

    Sahlstedt, Elina; Arppe, Laura

    2017-04-01

    Stable isotope composition of bones, analysed either from the mineral phase (hydroxyapatite) or from the organic phase (mainly collagen) carry important climatological and ecological information and are therefore widely used in paleontological and archaeological research. For the analysis of the stable isotope compositions, both of the phases, hydroxyapatite and collagen, have their more or less well established separation and analytical techniques. Recent development in IRMS and wet chemical extraction methods have facilitated the analysis of very small bone fractions (500 μg or less starting material) for PO43-O isotope composition. However, the uniqueness and (pre-) historical value of each archaeological and paleontological finding lead to preciously little material available for stable isotope analyses, encouraging further development of microanalytical methods for the use of stable isotope analyses. Here we present the first results in developing extraction methods for combining collagen C- and N-isotope analyses to PO43-O-isotope analyses from a single bone sample fraction. We tested sequential extraction starting with dilute acid demineralization and collection of both collagen and PO43-fractions, followed by further purification step by H2O2 (PO43-fraction). First results show that bone sample separates as small as 2 mg may be analysed for their δ15N, δ13C and δ18OPO4 values. The method may be incorporated in detailed investigation of sequentially developing skeletal material such as teeth, potentially allowing for the investigation of interannual variability in climatological/environmental signals or investigation of the early life history of an individual.

  1. Dietary Interventions in Multiple Sclerosis: Development and Pilot-Testing of an Evidence Based Patient Education Program.

    Science.gov (United States)

    Riemann-Lorenz, Karin; Eilers, Marlene; von Geldern, Gloria; Schulz, Karl-Heinz; Köpke, Sascha; Heesen, Christoph

    2016-01-01

    Dietary factors have been discussed to influence risk or disease course of multiple sclerosis (MS). Specific diets are widely used among patients with MS. To design and pilot-test an evidence based patient education program on dietary factors in MS. We performed a systematic literature search on the effectiveness of dietary interventions in MS. A web-based survey among 337 patients with MS and 136 healthy controls assessed knowledge, dietary habits and information needs. An interactive group education program was developed and pilot-tested. Fifteen randomised-controlled trials (RCTs) were included in the systematic review. Quality of evidence was low and no clear benefit could be seen. Patients with MS significantly more often adhered to a `Mediterranean Diet`(29.7% versus 14.0%, ppilot test of our newly developed patient education program with 13 participants showed excellent comprehensibility and the MS-specific content was judged as very important. However, the poor evidence base for dietary approaches in MS was perceived disappointing. Development and pilot-testing of an evidence-based patient education program on nutrition and MS is feasible. Patient satisfaction with the program suffers from the lack of evidence. Further research should focus on generating evidence for the potential influence of lifestyle habits (diet, physical activity) on MS disease course thus meeting the needs of patients with MS.

  2. MRD Testing in Multiple Myeloma: From a Surrogate Marker of Clinical Outcomes to an Every-Day Clinical Tool.

    Science.gov (United States)

    Landgren, Ola

    2018-01-01

    Minimal residual disease (MRD) testing in multiple myeloma is here to stay. Studies show that MRD negativity is consistently associated with longer progression-free survival (PFS). It is just a matter of time until MRD negativity will become a regulatory endpoint for drug approval. Until that can happen, more analysis will be required to define the exact details of MRD in the regulatory setting. For example, for randomized studies there is need to define the amount of improvement in MRD negativity between the experimental arm and the control arm at a given time-point for a drug to obtain regulatory accelerated approval. Such efforts are underway. For the multiple myeloma field as a whole, important tasks for the (near) coming future are as follows: (1) to conduct or finalize the expanded analysis to define the exact details of MRD in the regulatory setting, (2) to develop new and better MRD assays-both more sensitive MRD assays for bone marrow aspirates and nonbone marrow aspirate-based assays (eg, blood-based and imaging-based MRD assays), and (3) to design novel clinical studies to formally assess the effect of MRD negativity in clinical decision making. The aim with this issue of the Journal is to provide a deep and comprehensive summary of the latest MRD knowledge in the field, and to outline future directions. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Reliability and equivalence of alternate forms for the Symbol Digit Modalities Test: implications for multiple sclerosis clinical trials.

    Science.gov (United States)

    Benedict, Ralph H B; Smerbeck, Audrey; Parikh, Rajavi; Rodgers, Jonathan; Cadavid, Diego; Erlanger, David

    2012-09-01

    Cognitive impairment is common in multiple sclerosis (MS), but is seldom assessed in clinical trials investigating the effects of disease-modifying therapies. The Symbol Digit Modalities Test (SDMT) is a particularly promising tool due to its sensitivity and robust correlation with brain magnetic resonance imaging (MRI) and vocational disability. Unfortunately, there are no validated alternate SDMT forms, which are needed to mitigate practice effects. The aim of the study was to assess the reliability and equivalence of SDMT alternate forms. Twenty-five healthy participants completed each of five alternate versions of the SDMT - the standard form, two versions from the Rao Brief Repeatable Battery, and two forms specifically designed for this study. Order effects were controlled using a Latin-square research design. All five versions of the SDMT produced mean values within 3 raw score points of one another. Three forms were very consistent, and not different by conservative statistical tests. The SDMT test-retest reliability using these forms was good to excellent, with all r values exceeding 0.80. For the first time, we find good evidence that at least three alternate versions of the SDMT are of equivalent difficulty in healthy adults. The forms are reliable, and can be implemented in clinical trials emphasizing cognitive outcomes.

  4. The Cascading Effects of Multiple Dimensions of Implementation on Program Outcomes: a Test of a Theoretical Model.

    Science.gov (United States)

    Berkel, Cady; Mauricio, Anne M; Sandler, Irwin N; Wolchik, Sharlene A; Gallo, Carlos G; Brown, C Hendricks

    2017-12-14

    This study tests a theoretical cascade model in which multiple dimensions of facilitator delivery predict indicators of participant responsiveness, which in turn lead to improvements in targeted program outcomes. An effectiveness trial of the 10-session New Beginnings Program for divorcing families was implemented in partnership with four county-level family courts. This study included 366 families assigned to the intervention condition who attended at least one session. Independent observers provided ratings of program delivery (i.e., fidelity to the curriculum and process quality). Facilitators reported on parent attendance and parents' competence in home practice of program skills. At pretest and posttest, children reported on parenting and parents reported child mental health. We hypothesized effects of quality on attendance, fidelity and attendance on home practice, and home practice on improvements in parenting and child mental health. Structural Equation Modeling with mediation and moderation analyses were used to test these associations. Results indicated quality was significantly associated with attendance, and attendance moderated the effect of fidelity on home practice. Home practice was a significant mediator of the links between fidelity and improvements in parent-child relationship quality and child externalizing and internalizing problems. Findings provide support for fidelity to the curriculum, process quality, attendance, and home practice as valid predictors of program outcomes for mothers and fathers. Future directions for assessing implementation in community settings are discussed.

  5. TESTING THE GENERALIZATION EFFICIENCY OF OIL SLICK CLASSIFICATION ALGORITHM USING MULTIPLE SAR DATA FOR DEEPWATER HORIZON OIL SPILL

    Directory of Open Access Journals (Sweden)

    C. Ozkan

    2012-07-01

    Full Text Available Marine oil spills due to releases of crude oil from tankers, offshore platforms, drilling rigs and wells, etc. are seriously affecting the fragile marine and coastal ecosystem and cause political and environmental concern. A catastrophic explosion and subsequent fire in the Deepwater Horizon oil platform caused the platform to burn and sink, and oil leaked continuously between April 20th and July 15th of 2010, releasing about 780,000 m3 of crude oil into the Gulf of Mexico. Today, space-borne SAR sensors are extensively used for the detection of oil spills in the marine environment, as they are independent from sun light, not affected by cloudiness, and more cost-effective than air patrolling due to covering large areas. In this study, generalization extent of an object based classification algorithm was tested for oil spill detection using multiple SAR imagery data. Among many geometrical, physical and textural features, some more distinctive ones were selected to distinguish oil and look alike objects from each others. The tested classifier was constructed from a Multilayer Perception Artificial Neural Network trained by ABC, LM and BP optimization algorithms. The training data to train the classifier were constituted from SAR data consisting of oil spill originated from Lebanon in 2007. The classifier was then applied to the Deepwater Horizon oil spill data in the Gulf of Mexico on RADARSAT-2 and ALOS PALSAR images to demonstrate the generalization efficiency of oil slick classification algorithm.

  6. Test–Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Clare E. Palmer

    2018-01-01

    Full Text Available Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington’s disease (HD and Parkinson’s disease (PD across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test–retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test–retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test–retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT from the combined-Simon-Stop-Signal task showed moderate test–retest reliability, however, the combined SSRT interference effect showed poor test–retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  7. Urban residential greenspace and mental health in youth: Different approaches to testing multiple pathways yield different conclusions.

    Science.gov (United States)

    Dzhambov, Angel; Hartig, Terry; Markevych, Iana; Tilov, Boris; Dimitrova, Donka

    2018-01-01

    Urban greenspace can benefit mental health through multiple mechanisms. They may work together, but previous studies have treated them as independent. We aimed to compare single and parallel mediation models, which estimate the independent contributions of different paths, to several models that posit serial mediation components in the pathway from greenspace to mental health. We collected cross-sectional survey data from 399 participants (15-25 years of age) in the city of Plovdiv, Bulgaria. Objective "exposure" to urban residential greenspace was defined by the Normalized Difference Vegetation Index (NDVI), Soil Adjusted Vegetation Index, tree cover density within the 500-m buffer, and Euclidean distance to the nearest urban greenspace. Self-reported measures of availability, access, quality, and usage of greenspace were also used. Mental health was measured with the General Health Questionnaire. The following potential mediators were considered in single and parallel mediation models: restorative quality of the neighborhood, neighborhood social cohesion, commuting and leisure time physical activity, road traffic noise annoyance, and perceived air pollution. Four models were tested with the following serial mediation components: (1) restorative quality → social cohesion; (2) restorative quality → physical activity; (3) perceived traffic pollution → restorative quality; (4) and noise annoyance → physical activity. There was no direct association between objectively-measured greenspace and mental health. For the 500-m buffer, the tests of the single mediator models suggested that restorative quality mediated the relationship between NDVI and mental health. Tests of parallel mediation models did not find any significant indirect effects. In line with theory, tests of the serial mediation models showed that higher restorative quality was associated with more physical activity and more social cohesion, and in turn with better mental health. As for self

  8. Benefits and challenges of using the cohort multiple randomised controlled trial design for testing an intervention for depression.

    Science.gov (United States)

    Viksveen, Petter; Relton, Clare; Nicholl, Jon

    2017-07-06

    Trials which test the effectiveness of interventions compared with the status quo frequently encounter challenges. The cohort multiple randomised controlled trial (cmRCT) design is an innovative approach to the design and conduct of pragmatic trials which seeks to address some of these challenges. In this article, we report our experiences with the first completed randomised controlled trial (RCT) using the cmRCT design. This trial-the Depression in South Yorkshire (DEPSY) trial-involved comparison of treatment as usual (TAU) with TAU plus the offer of an intervention for people with self-reported long-term moderate to severe depression. In the trial, we used an existing large population-based cohort: the Yorkshire Health Study. We discuss our experiences with recruitment, attrition, crossover, data analysis, generalisability of results, and cost. The main challenges in using the cmRCT design were the high crossover to the control group and the lower questionnaire response rate among patients who refused the offer of treatment. However, the design did help facilitate efficient and complete recruitment of the trial population as well as analysable data that were generalisable to the population of interest. Attrition rates were also smaller than those reported in other depression trials. This first completed full trial using the cmRCT design testing an intervention for self-reported depression was associated with a number of important benefits. Further research is required to compare the acceptability and cost effectiveness of standard pragmatic RCT design with the cmRCT design. ISRCTN registry: ISRCTN02484593 . Registered on 7 Jan 2013.

  9. Quick screening of cognitive function in Indian multiple sclerosis patients using Montreal cognitive assessment test-short version

    Directory of Open Access Journals (Sweden)

    Darshpreet Kaur

    2013-01-01

    Full Text Available Background: Cognitive impairments in multiple sclerosis (MS are now well recognized worldwide, but unfortunately this domain has been less explored in India due to many undermining factors. The aim of this study was to evaluate cognitive impairments in Indian MS patients with visual or upper limb motor problems with the help of short version of Montreal cognitive assessment test (MoCA. Subjects and Methods: Thirty MS patients and 50 matched controls were recruited for the 12 points MoCA task. Receiver operating characteristic curve (ROC analysis was performed to determine optimal sensitivity and specificity of the 12 points MoCA in differentiating cognitively impaired patients and controls. Results: The mean 12 points MoCA scores of the controls and MS patients were 11.56 ± 0.67 and 8.06 ± 1.99, respectively. In our study, the optimal cut-off value for 12 points MoCA to be able to differentiate patients with cognitive impairments from controls is 10/12. Accordingly, 73.3% patients fell below the cut off value. Both the groups did not have significant statistical differences with regard to age and educational years. Conclusion: The 12 points, short version of MoCA, is a useful brief screening tool for quick and early detection of mild cognitive impairments in subjects with MS. It can be administered to patients having visual and motor problems. It is of potential use by primary care physicians, nurses, and other allied health professionals who need a quick screening test. No formal training for administration is required. Financial and time constraints should not limit the use of the proposed instrument.

  10. Clinical usefulness of serum free light chains measurement in patients with multiple myeloma: comparative analysis of two different tests

    Directory of Open Access Journals (Sweden)

    Tadeusz Kubicki

    2017-01-01

    Full Text Available Introduction: There are two commercially available tests for measurement of serum free light chains (sFLC in multiple myeloma (MM patients – Freelite and N Latex FLC. The aim of this study was to perform an assessment and direct comparison of the usefulness of the methods in routine clinical practice.Methods: 40 refractory/relapsed MM patients underwent routine disease activity assessment studies, along with sFLC analysis using both assays. Correlation and concordance between the tests and sensitivity of studied methods of sFLC assessment were established. Special attention was focused on sFLC results in patients finally evaluated after completing the treatment. Results: A weak correlation for the measurement of both κ [Passing–Bablok slope (PB = 0.7681] and λ chains [(PB = 1.542] was found. Using Bland–Altman plots, a bias of 0.0467 (κ and -0.2133 (λ between the measurements was documented. The concordance coefficient equaled 0.87 for κ, 0.62 for λ and 0.52 for κ/λ ratio. Ten patients had an abnormal Freelite assay κ/λ ratio and normal N Latex FLC κ/λ ratio. Three of these patients had negative serum protein electrophoresis results and fulfilled diagnostic criteria of stringent complete remission (sCR according to N Latex FLC (but not according to Freelite. When the κ/λ ratio obtained by both methods was compared to patients’ serum/urine protein electrophoresis and immunofixation results, sensitivity of Freelite and N Latex FLC was established to be 62.5% and 41%, respectively. Conclusions: There was no strong correlation or concordance between the two assays, and the sensitivity in terms of sFLC detection was different. This may cause problems when diagnosis of sCR is considered.

  11. Evidence for the different physiological significance of the 6- and 2-minute walk tests in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Motl Robert W

    2012-03-01

    Full Text Available Abstract Background Researchers have recently advocated for the 2-minute walk (2MW as an alternative for the 6-minute walk (6MW to assess long distance ambulation in persons with multiple sclerosis (MS. This recommendation has not been based on physiological considerations such as the rate of oxygen consumption (V·O2 over the 6MW range. Objective This study examined the pattern of change in V·O2 over the range of the 6MW in a large sample of persons with MS who varied as a function of disability status. Method Ninety-five persons with clinically-definite MS underwent a neurological examination for generating an Expanded Disability Status Scale (EDSS score, and then completion of the 6MW protocol while wearing a portable metabolic unit and an accelerometer. Results There was a time main effect on V·O2 during the 6MW (p = .0001 such that V·O2 increased significantly every 30 seconds over the first 3 minutes of the 6MW, and then remained stable over the second 3 minutes of the 6MW. This occurred despite no change in cadence across the 6MW (p = .84. Conclusions The pattern of change in V·O2 indicates that there are different metabolic systems providing energy for ambulation during the 6MW in MS subjects and steady state aerobic metabolism is reached during the last 3 minutes of the 6MW. By extension, the first 3 minutes would represent a test of mixed aerobic and anaerobic work, whereas the second 3 minutes would represent a test of aerobic work during walking.

  12. Improving Healthcare in Pediatric Oncology: Development and Testing of Multiple Indicators to Evaluate a Hub-And-Spoke Model.

    Science.gov (United States)

    Zucchetti, Giulia; Bertorello, Nicoletta; Angelastro, Angela; Gianino, Paola; Bona, Gianni; Barbara, Affif; Besenzon, Luigi; Brach Del Prever, Adalberto; Pesce, Fernando; Nangeroni, Marco; Fagioli, Franca

    2017-06-01

    Purpose The hub-and-spoke is a new innovation model in healthcare that has been adopted in some countries to manage rare pathologies. We developed a set of indicators to assess current quality practices of the hub-and-spoke model adopted in the Interregional Pediatric Oncology Network in Northwest Italy and to promote patient, family, and professional healthcare empowerment. Methods Literature and evidence-based clinical guidelines were reviewed and multiprofessional team workshops were carried out to highlight some important issues on healthcare in pediatric oncology and to translate them into a set of multiple indicators. For each indicator, specific questions were formulated and tested through a series of questionnaires completed by 80 healthcare professionals and 50 pediatric patients and their parents. Results The results highlighted a positive perception of healthcare delivered by the hub-and-spoke model (M HP = 156, M Pat = 93, M Par = 104). Based on the participants' suggestions, some quality improvements have been implemented. Conclusions This study represents the first attempt to examine this new model of pediatric oncology care through the active involvement of patients, families, and healthcare professionals. Suggestions for adopting a hub-and-spoke model in pediatric oncology in other regions and countries are also highlighted.

  13. Item difficulty of multiple choice tests dependant on different item response formats – An experiment in fundamental research on psychological assessment

    Directory of Open Access Journals (Sweden)

    KLAUS D. KUBINGER

    2007-12-01

    Full Text Available Multiple choice response formats are problematical as an item is often scored as solved simply because the test-taker is a lucky guesser. Instead of applying pertinent IRT models which take guessing effects into account, a pragmatic approach of re-conceptualizing multiple choice response formats to reduce the chance of lucky guessing is considered. This paper compares the free response format with two different multiple choice formats. A common multiple choice format with a single correct response option and five distractors (“1 of 6” is used, as well as a multiple choice format with five response options, of which any number of the five is correct and the item is only scored as mastered if all the correct response options and none of the wrong ones are marked (“x of 5”. An experiment was designed, using pairs of items with exactly the same content but different response formats. 173 test-takers were randomly assigned to two test booklets of 150 items altogether. Rasch model analyses adduced a fitting item pool, after the deletion of 39 items. The resulting item difficulty parameters were used for the comparison of the different formats. The multiple choice format “1 of 6” differs significantly from “x of 5”, with a relative effect of 1.63, while the multiple choice format “x of 5” does not significantly differ from the free response format. Therefore, the lower degree of difficulty of items with the “1 of 6” multiple choice format is an indicator of relevant guessing effects. In contrast the “x of 5” multiple choice format can be seen as an appropriate substitute for free response format.

  14. Investigation of the Validity and Reliability of Balance Evaluation Systems Test (BESTest in Assessment of Balance Disorders in People With Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Samira Kamalian Lari

    2018-01-01

    Conclusion  After changing and removing part of question 6 of the second domain, results demonstrated that the questionnaire BESTest is a valid and reliable test for assessing balance performance in multiple sclerosis patients. It can be used as an accurate tool, both in the areas of clinical (to evaluate the patients’ equilibrium status and purposeful therapy planning and to apply for scientific research in patients with multiple sclerosis.

  15. A Computerized Lifestyle Application to Promote Multiple Health Behaviors at the Workplace: Testing Its Behavioral and Psychological Effects.

    Science.gov (United States)

    Lippke, Sonia; Fleig, Lena; Wiedemann, Amelie U; Schwarzer, Ralf

    2015-10-01

    Preventive health behaviors, such as regular physical activity and healthy nutrition, are recommended to maintain employability and to facilitate the health of employees. Theory-based workplace health promotion needs to include psychological constructs and consider the motivational readiness (so-called stages of change) of employees. According to the stages, people can be grouped as nonintenders (not motivated to change and not performing the goal behavior), intenders (decided to adopt the goal behavior but not started yet), or actors (performing the goal behavior already). The tailoring to these stages can be done computer based and should make workplace health promotion more effective. It was tested whether a parsimonious computer-based health promotion program implemented at the workplace was effective in terms of lifestyle changes and psychological outcomes as well as body weight. We hypothesized that the stage-matched intervention would outperform the one-size-fits-all active control condition (standard care intervention). In a randomized controlled trial, a total of 1269 employees were recruited by a trained research assistant at their workplace during a routine medical examination. After excluding noneligible employees, 560 completed Time 1 (T1), and 384 also completed Time 2 (T2), achieving a retention rate of 68.6%. Two fully automated computer-based treatments were adopted: (1) an active control condition with information about benefits of exercise and healthy nutrition (n=52), or (2) a stage-matched multiple-behavior intervention that provided different psychological treatments to 9 subgroups, addressing stages of change (nonintenders, intenders, and actors per behavior; n=332). Baseline assessments (T1) on behavior, psychological constructs, and body weight were repeated after 4 weeks (T2). The stage-matched intervention outperformed the active control condition for lifestyle changes containing physical activity and nutrition (χ(2) 1=3.5; P=.04, for N

  16. A Computerized Lifestyle Application to Promote Multiple Health Behaviors at the Workplace: Testing Its Behavioral and Psychological Effects

    Science.gov (United States)

    Fleig, Lena; Wiedemann, Amelie U; Schwarzer, Ralf

    2015-01-01

    Background Preventive health behaviors, such as regular physical activity and healthy nutrition, are recommended to maintain employability and to facilitate the health of employees. Theory-based workplace health promotion needs to include psychological constructs and consider the motivational readiness (so-called stages of change) of employees. According to the stages, people can be grouped as nonintenders (not motivated to change and not performing the goal behavior), intenders (decided to adopt the goal behavior but not started yet), or actors (performing the goal behavior already). The tailoring to these stages can be done computer based and should make workplace health promotion more effective. Objective It was tested whether a parsimonious computer-based health promotion program implemented at the workplace was effective in terms of lifestyle changes and psychological outcomes as well as body weight. We hypothesized that the stage-matched intervention would outperform the one-size-fits-all active control condition (standard care intervention). Methods In a randomized controlled trial, a total of 1269 employees were recruited by a trained research assistant at their workplace during a routine medical examination. After excluding noneligible employees, 560 completed Time 1 (T1), and 384 also completed Time 2 (T2), achieving a retention rate of 68.6%. Two fully automated computer-based treatments were adopted: (1) an active control condition with information about benefits of exercise and healthy nutrition (n=52), or (2) a stage-matched multiple-behavior intervention that provided different psychological treatments to 9 subgroups, addressing stages of change (nonintenders, intenders, and actors per behavior; n=332). Baseline assessments (T1) on behavior, psychological constructs, and body weight were repeated after 4 weeks (T2). Results The stage-matched intervention outperformed the active control condition for lifestyle changes containing physical activity and

  17. Nurse-led immunotreatment DEcision Coaching In people with Multiple Sclerosis (DECIMS) - Feasibility testing, pilot randomised controlled trial and mixed methods process evaluation.

    Science.gov (United States)

    Rahn, A C; Köpke, S; Backhus, I; Kasper, J; Anger, K; Untiedt, B; Alegiani, A; Kleiter, I; Mühlhauser, I; Heesen, C

    2018-02-01

    Treatment decision-making is complex for people with multiple sclerosis. Profound information on available options is virtually not possible in regular neurologist encounters. The "nurse decision coach model" was developed to redistribute health professionals' tasks in supporting immunotreatment decision-making following the principles of informed shared decision-making. To test the feasibility of a decision coaching programme and recruitment strategies to inform the main trial. Feasibility testing and parallel pilot randomised controlled trial, accompanied by a mixed methods process evaluation. Two German multiple sclerosis university centres. People with suspected or relapsing-remitting multiple sclerosis facing immunotreatment decisions on first line drugs were recruited. Randomisation to the intervention (n = 38) or control group (n = 35) was performed on a daily basis. Quantitative and qualitative process data were collected from people with multiple sclerosis, nurses and physicians. We report on the development and piloting of the decision coaching programme. It comprises a training course for multiple sclerosis nurses and the coaching intervention. The intervention consists of up to three structured nurse-led decision coaching sessions, access to an evidence-based online information platform (DECIMS-Wiki) and a final physician consultation. After feasibility testing, a pilot randomised controlled trial was performed. People with multiple sclerosis were randomised to the intervention or control group. The latter had also access to the DECIMS-Wiki, but received otherwise care as usual. Nurses were not blinded to group assignment, while people with multiple sclerosis and physicians were. The primary outcome was 'informed choice' after six months including the sub-dimensions' risk knowledge (after 14 days), attitude concerning immunotreatment (after physician consultation), and treatment uptake (after six months). Quantitative process evaluation data

  18. Item and test analysis to identify quality multiple choice questions (MCQS from an assessment of medical students of Ahmedabad, Gujarat

    Directory of Open Access Journals (Sweden)

    Sanju Gajjar

    2014-01-01

    Full Text Available Background: Multiple choice questions (MCQs are frequently used to assess students in different educational streams for their objectivity and wide reach of coverage in less time. However, the MCQs to be used must be of quality which depends upon its difficulty index (DIF I, discrimination index (DI and distracter efficiency (DE. Objective: To evaluate MCQs or items and develop a pool of valid items by assessing with DIF I, DI and DE and also to revise/ store or discard items based on obtained results. Settings: Study was conducted in a medical school of Ahmedabad. Materials and Methods: An internal examination in Community Medicine was conducted after 40 hours teaching during 1 st MBBS which was attended by 148 out of 150 students. Total 50 MCQs or items and 150 distractors were analyzed. Statistical Analysis: Data was entered and analyzed in MS Excel 2007 and simple proportions, mean, standard deviations, coefficient of variation were calculated and unpaired t test was applied. Results: Out of 50 items, 24 had "good to excellent" DIF I (31 - 60% and 15 had "good to excellent" DI (> 0.25. Mean DE was 88.6% considered as ideal/ acceptable and non functional distractors (NFD were only 11.4%. Mean DI was 0.14. Poor DI (< 0.15 with negative DI in 10 items indicates poor preparedness of students and some issues with framing of at least some of the MCQs. Increased proportion of NFDs (incorrect alternatives selected by < 5% students in an item decrease DE and makes it easier. There were 15 items with 17 NFDs, while rest items did not have any NFD with mean DE of 100%. Conclusion: Study emphasizes the selection of quality MCQs which truly assess the knowledge and are able to differentiate the students of different abilities in correct manner.

  19. Evaluation of autonomic functions of patients with multiple system atrophy and Parkinson's disease by head-up tilt test.

    Science.gov (United States)

    Watano, Chikako; Shiota, Yuri; Onoda, Keiichi; Sheikh, Abdullah Md; Mishima, Seiji; Nitta, Eri; Yano, Shozo; Yamaguchi, Shuhei; Nagai, Atsushi

    2018-02-01

    The aim of this study was to evaluate the autonomic neural function in Parkinson's disease (PD) and multiple system atrophy (MSA) with head-up tilt test and spectral analysis of cardiovascular parameters. This study included 15 patients with MSA, 15 patients with PD, and 29 healthy control (HC) subjects. High frequency power of the RR interval (RR-HF), the ratio of low frequency power of RR interval to RR-HF (RR-LF/HF) and LF power of systolic BP were used to evaluate parasympathetic, cardiac sympathetic and vasomotor sympathetic functions, respectively. Both patients with PD and MSA showed orthostatic hypotension and lower parasympathetic function (RR-HF) at tilt position as compared to HC subjects. Cardiac sympathetic function (RR-LF/HF) was significantly high in patients with PD than MSA at supine position. RR-LF/HF tended to increase in MSA and HC, but decreased in PD by tilting. Consequently, the change of the ratio due to tilting (ΔRR-LF/HF) was significantly lower in patients with PD than in HC subjects. Further analysis showed that compared to mild stage of PD, RR-LF/HF at the supine position was significantly higher in advanced stage. By tilting, it was increased in mild stage and decreased in the advanced stage of PD, causing ΔRR-LF/HF to decrease significantly in the advanced stage. Thus, we demonstrated that spectral analysis of cardiovascular parameters is useful to identify sympathetic and parasympathetic disorders in MSA and PD. High cardiac sympathetic function at the supine position, and its reduction by tilting might be a characteristic feature of PD, especially in the advanced stage.

  20. Multi-stratified multiple regression tests of the linear/no-threshold theory of radon-induced lung cancer

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1992-01-01

    A plot of lung-cancer rates versus radon exposures in 965 US counties, or in all US states, has a strong negative slope, b, in sharp contrast to the strong positive slope predicted by linear/no-threshold theory. The discrepancy between these slopes exceeds 20 standard deviations (SD). Including smoking frequency in the analysis substantially improves fits to a linear relationship but has little effect on the discrepancy in b, because correlations between smoking frequency and radon levels are quite weak. Including 17 socioeconomic variables (SEV) in multiple regression analysis reduces the discrepancy to 15 SD. Data were divided into segments by stratifying on each SEV in turn, and on geography, and on both simultaneously, giving over 300 data sets to be analyzed individually, but negative slopes predominated. The slope is negative whether one considers only the most urban counties or only the most rural; only the richest or only the poorest; only the richest in the South Atlantic region or only the poorest in that region, etc., etc.,; and for all the strata in between. Since this is an ecological study, the well-known problems with ecological studies were investigated and found not to be applicable here. The open-quotes ecological fallacyclose quotes was shown not to apply in testing a linear/no-threshold theory, and the vulnerability to confounding is greatly reduced when confounding factors are only weakly correlated with radon levels, as is generally the case here. All confounding factors known to correlate with radon and with lung cancer were investigated quantitatively and found to have little effect on the discrepancy

  1. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  2. Dynamic Testing of Analogical Reasoning in 5- to 6-Year-Olds : Multiple-Choice Versus Constructed-Response Training Items

    NARCIS (Netherlands)

    Stevenson, C.E.; Heiser, W.J.; Resing, W.C.M.

    2016-01-01

    Multiple-choice (MC) analogy items are often used in cognitive assessment. However, in dynamic testing, where the aim is to provide insight into potential for learning and the learning process, constructed-response (CR) items may be of benefit. This study investigated whether training with CR or MC

  3. Evaluation of Closed Adult Nucleus Multiple Ovulation and Embryo Transfer and Conventional Progeny Testing Breeding Schemes for Milk Production from Crossbred Cattle in the Tropics

    NARCIS (Netherlands)

    Kosgey, I.S.; Kahi, A.K.; Arendonk, van J.A.M.

    2005-01-01

    The potential benefits of closed adult nucleus multiple ovulation and embryo transfer (MOET) and conventional progeny testing (CNS) schemes, and the logistics of their integration into large-scale continuous production of crossbred cattle were studied by deterministic simulation. The latter was

  4. Multiple testing issues in discriminating compound-related peaks and chromatograms from high frequency noise, spikes and solvent-based nois in LC-MS data sets

    NARCIS (Netherlands)

    Nyangoma, S.O.; Van Kampen, A.A.; Reijmers, T.H.; Govorukhina, N.I; van der Zee, A.G.; Billingham, I.J; Bischoff, Rainer; Jansen, R.C.

    2007-01-01

    Multiple testing issues in discriminating compound-related peaks and chromatograms from high frequency noise, spikes and solvent-based noise in LC-MS data sets.Nyangoma SO, van Kampen AA, Reijmers TH, Govorukhina NI, van der Zee AG, Billingham LJ, Bischoff R, Jansen RC. University of Birmingham.

  5. Dynamic Testing of Analogical Reasoning in 5- to 6-Year-Olds: Multiple-Choice versus Constructed-Response Training Items

    Science.gov (United States)

    Stevenson, Claire E.; Heiser, Willem J.; Resing, Wilma C. M.

    2016-01-01

    Multiple-choice (MC) analogy items are often used in cognitive assessment. However, in dynamic testing, where the aim is to provide insight into potential for learning and the learning process, constructed-response (CR) items may be of benefit. This study investigated whether training with CR or MC items leads to differences in the strategy…

  6. Multiple-Choice Testing Using Immediate Feedback--Assessment Technique (IF AT®) Forms: Second-Chance Guessing vs. Second-Chance Learning?

    Science.gov (United States)

    Merrel, Jeremy D.; Cirillo, Pier F.; Schwartz, Pauline M.; Webb, Jeffrey A.

    2015-01-01

    Multiple choice testing is a common but often ineffective method for evaluating learning. A newer approach, however, using Immediate Feedback Assessment Technique (IF AT®, Epstein Educational Enterprise, Inc.) forms, offers several advantages. In particular, a student learns immediately if his or her answer is correct and, in the case of an…

  7. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    Science.gov (United States)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  8. 'Ya'yan Magajiya (Errand Children) in Nigeria

    African Journals Online (AJOL)

    Administrator

    more than the amount the indigenes pay their Saratanyas for similar work. ... pastures, they are not harassed as women are, and most of the domestics are culturally ... of the low-income and peasant houses had saratanya. Those poor that had ...

  9. CPR in the nursing home: fool's errand or looming dilemma?

    LENUS (Irish Health Repository)

    Lyons, D

    2011-09-01

    The indications for CPR (cardiopulmonary resuscitation) have expanded greatly since the technique was introduced and theoretically it can be attempted on all prior to death. Policy initiatives (such as the British Medical Association\\/Royal College of Nursing guidelines) have attempted to provide a clinical rationale for the withholding of inappropriate CPR. Traditionally a care home was felt to be an inappropriate environment to attempt CPR but increased use of advance directives may bring the issue to the fore in this setting.

  10. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    Science.gov (United States)

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  11. Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis

    DEFF Research Database (Denmark)

    Møller, Andreas Buch; Bibby, Bo Martin; Guldhammer, Anders

    2012-01-01

    familiarization test session and two testing sessions. In Group A, session 1 also included assessment of lower extremity muscle strength. Session 2 and 3 involved completion of two 5STS-tests and assessment of balance. In Group B, session 2 and 3 involved completion of two rounds of two 5STS-tests separated...

  12. Additive and Multiplicative Effects of Working Memory and Test Anxiety on Mathematics Performance in Grade 3 Students

    Science.gov (United States)

    Korhonen, Johan; Nyroos, Mikaela; Jonsson, Bert; Eklöf, Hanna

    2018-01-01

    The aim of this study was to investigate the interplay between test anxiety and working memory (WM) on mathematics performance in younger children. A sample of 624 grade 3 students completed a test battery consisting of a test anxiety scale, WM tasks and the Swedish national examination in mathematics for grade 3. The main effects of test anxiety…

  13. Science Library of Test Items. Volume Twenty-One. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 2.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  14. p-hacking by post hoc selection with multiple opportunities: Detectability by skewness test?: Comment on Simonsohn, Nelson, and Simmons (2014).

    Science.gov (United States)

    Ulrich, Rolf; Miller, Jeff

    2015-12-01

    Simonsohn, Nelson, and Simmons (2014) have suggested a novel test to detect p-hacking in research, that is, when researchers report excessive rates of "significant effects" that are truly false positives. Although this test is very useful for identifying true effects in some cases, it fails to identify false positives in several situations when researchers conduct multiple statistical tests (e.g., reporting the most significant result). In these cases, p-curves are right-skewed, thereby mimicking the existence of real effects even if no effect is actually present. (c) 2015 APA, all rights reserved).

  15. Multiple Homicide as a Function of Prisonization and Concurrent Instrumental Violence: Testing an Interactive Model--A Research Note

    Science.gov (United States)

    DeLisi, Matt; Walters, Glenn D.

    2011-01-01

    Prisonization (as measured by number of prior incarcerations) and concurrent instrumental offending (as measured by contemporaneous kidnapping, rape, robbery, and burglary offenses) were found to interact in 160 multiple-homicide offenders and 494 single-homicide offenders. Controlling for age, gender, race, criminal history, prior incarcerations,…

  16. Which walking capacity tests to use in multiple sclerosis? A multicentre study providing the basis for a core set

    NARCIS (Netherlands)

    Gijbels, D.; Dalgas, U.; Romberg, A.; de Groot, V.; Bethoux, F.; Vaney, C.; Gebara, B.; Santoyo, C.; Maamagi, H.; Rasova, K.; de Maertens, N.B.; Knuts, K.; Feys, P.

    2012-01-01

    Background: Many different walking capacity test formats are being used. It is unclear whether walking speed, obtained from short tests, and walking distance, obtained from long tests, provide different clinical information. Objectives: To determine the differential effect of various short and long

  17. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Knudsen, L; Jensen, K

    1994-01-01

    In a cross-sectional study of 94 patients (42 males, 52 females) with definite multiple sclerosis (MS) in the age range 25-55 years, the correlation of neuropsychological tests with the ability to read TV-subtitles and with the use of sedatives is examined. A logistic regression analysis reveals...

  18. A case report of a Wada test after dominant hemisphere multiple hippocampal transections: Pathophysiology of confusion after amobarbital injection

    Directory of Open Access Journals (Sweden)

    Patrick Landazuri

    2014-01-01

    Full Text Available Dialepsis is defined as a predominant alteration of consciousness with preservation of motor tone and the ability to perform movements. While dialepsis is a common feature of both focal and generalized epilepsies, its precise symptomatogenic zone and pathogenesis remain undefined. This case report describes a patient who underwent intracarotid amobarbital procedures before and after dominant hemisphere multiple hippocampal transections. From our observations, we propose a possible pathogenesis for the generation of dialeptic seizures.

  19. Power Hardware-in-the-Loop Testing of Multiple Photovoltaic Inverters' Volt-Var Control with Real-Time Grid Model

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Nelson, Austin; Hoke, Anderson

    2016-12-12

    Traditional testing methods fall short in evaluating interactions between multiple smart inverters providing advanced grid support functions due to the fact that such interactions largely depend on their placements on the electric distribution systems with impedances between them. Even though significant concerns have been raised by the utilities on the effects of such interactions, little effort has been made to evaluate them. In this paper, power hardware-in-the-loop (PHIL) based testing was utilized to evaluate autonomous volt-var operations of multiple smart photovoltaic (PV) inverters connected to a simple distribution feeder model. The results provided in this paper show that depending on volt-var control (VVC) parameters and grid parameters, interaction between inverters and between the inverter and the grid is possible in some extreme cases with very high VVC slopes, fast response times and large VVC response delays.

  20. Multiple Approaches for Testing Novel Coatings in the Laboratory and in Pearl Harbor, Hawaii with Emphasis on the Global, Problem-Fouling Invertebrates

    Science.gov (United States)

    2015-09-25

    Multiple Approaches for Testing Novel Coatings in the Laboratory and in Pearl Harbor, Hawaii with Emphasis on the Global, Problem-Fouling Invertebrates 5a...on the Global, Problem-Fouling Invertebrates ONR AWARD NUMBER: N00014-11-1-0167 PRINCIPLE INVESTIGATOR: Michael G. Hadfield, Ph.D...luteoviolacea a phage tail-like component that is capable of inducing the metamorphosis of a marine invertebrate . However, our continued studies in the

  1. Effect of response format on cognitive reflection: Validating a two- and four-option multiple choice question version of the Cognitive Reflection Test.

    Science.gov (United States)

    Sirota, Miroslav; Juanchich, Marie

    2018-03-27

    The Cognitive Reflection Test, measuring intuition inhibition and cognitive reflection, has become extremely popular because it reliably predicts reasoning performance, decision-making, and beliefs. Across studies, the response format of CRT items sometimes differs, based on the assumed construct equivalence of tests with open-ended versus multiple-choice items (the equivalence hypothesis). Evidence and theoretical reasons, however, suggest that the cognitive processes measured by these response formats and their associated performances might differ (the nonequivalence hypothesis). We tested the two hypotheses experimentally by assessing the performance in tests with different response formats and by comparing their predictive and construct validity. In a between-subjects experiment (n = 452), participants answered stem-equivalent CRT items in an open-ended, a two-option, or a four-option response format and then completed tasks on belief bias, denominator neglect, and paranormal beliefs (benchmark indicators of predictive validity), as well as on actively open-minded thinking and numeracy (benchmark indicators of construct validity). We found no significant differences between the three response formats in the numbers of correct responses, the numbers of intuitive responses (with the exception of the two-option version, which had a higher number than the other tests), and the correlational patterns of the indicators of predictive and construct validity. All three test versions were similarly reliable, but the multiple-choice formats were completed more quickly. We speculate that the specific nature of the CRT items helps build construct equivalence among the different response formats. We recommend using the validated multiple-choice version of the CRT presented here, particularly the four-option CRT, for practical and methodological reasons. Supplementary materials and data are available at https://osf.io/mzhyc/ .

  2. Unified Sequence-Based Association Tests Allowing for Multiple Functional Annotations and Meta-analysis of Noncoding Variation in Metabochip Data.

    Science.gov (United States)

    He, Zihuai; Xu, Bin; Lee, Seunggeun; Ionita-Laza, Iuliana

    2017-09-07

    Substantial progress has been made in the functional annotation of genetic variation in the human genome. Integrative analysis that incorporates such functional annotations into sequencing studies can aid the discovery of disease-associated genetic variants, especially those with unknown function and located outside protein-coding regions. Direct incorporation of one functional annotation as weight in existing dispersion and burden tests can suffer substantial loss of power when the functional annotation is not predictive of the risk status of a variant. Here, we have developed unified tests that can utilize multiple functional annotations simultaneously for integrative association analysis with efficient computational techniques. We show that the proposed tests significantly improve power when variant risk status can be predicted by functional annotations. Importantly, when functional annotations are not predictive of risk status, the proposed tests incur only minimal loss of power in relation to existing dispersion and burden tests, and under certain circumstances they can even have improved power by learning a weight that better approximates the underlying disease model in a data-adaptive manner. The tests can be constructed with summary statistics of existing dispersion and burden tests for sequencing data, therefore allowing meta-analysis of multiple studies without sharing individual-level data. We applied the proposed tests to a meta-analysis of noncoding rare variants in Metabochip data on 12,281 individuals from eight studies for lipid traits. By incorporating the Eigen functional score, we detected significant associations between noncoding rare variants in SLC22A3 and low-density lipoprotein and total cholesterol, associations that are missed by standard dispersion and burden tests. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  3. Predictive value of testing for multiple genetic variants in multifactorial diseases: implications for the discourse on ethical, legal and social issues

    Directory of Open Access Journals (Sweden)

    A. Cecile J.W. Janssens

    2006-12-01

    Full Text Available Multifactorial diseases such as type 2 diabetes, osteoporosis, and cardiovascular disease are caused by a complex interplay of many genetic and nongenetic factors, each of which conveys a minor increase in the risk of disease. Unraveling the genetic origins of these diseases is expected to lead to individualized medicine, in which the prevention and treatment strategies are personalized on the basis of the results of predictive genetic tests. This great optimism is counterbalanced by concerns about the ethical, legal, and social implications of genomic medicine, such as the protection of privacy and autonomy, stigmatization, discrimination, and the psychological burden of genetic testing. These concerns are translated from genetic testing in monogenic disorders, but this translation may not be appropriate. Multiple genetic testing (genomic profiling has essential differences from genetic testing in monogenic disorders. The differences lie in the lower predictive value of the test results, the pleiotropic effects of susceptibility genes, and the low inheritance of genomic profiles. For these reasons, genomic profiling may be more similar to nongenetic tests than to predictive tests for monogenic diseases. Therefore, ethical, legal, and social issues that apply to predictive genetic testing for monogenic diseases may not be relevant for the prediction of multifactorial disorders in genomic medicine.

  4. Low adolescent self-esteem leads to multiple interpersonal problems: a test a social-adaptation theory.

    Science.gov (United States)

    Kahle, L R; Kulka, R A; Klingel, D M

    1980-09-01

    This article reports the results of a study that annually monitored the self-esteem and interpersonal problems of over 100 boys during their sophomore, junior, and senior years of high school. Cross-lagged panel correlation differences show that low self-esteem leads to interpersonal problems in all three time lags when multiple interpersonal problems constitute the dependent variable but not when single interpersonal problem criteria constitute the dependent variable. These results are interpreted as supporting social-adaptation theory rather than self-perception theory. Implications for the conceptual status of personality variables as causal antecedents and for the assessment of individual differences are discussed.

  5. Spatial and visuospatial working memory tests predict performance in classic multiple-object tracking in young adults, but nonspatial measures of the executive do not.

    Science.gov (United States)

    Trick, Lana M; Mutreja, Rachna; Hunt, Kelly

    2012-02-01

    An individual-differences approach was used to investigate the roles of visuospatial working memory and the executive in multiple-object tracking. The Corsi Blocks and Visual Patterns Tests were used to assess visuospatial working memory. Two relatively nonspatial measures of the executive were used: operation span (OSPAN) and reading span (RSPAN). For purposes of comparison, the digit span test was also included (a measure not expected to correlate with tracking). The tests predicted substantial amounts of variance (R (2) = .33), and the visuospatial measures accounted for the majority (R (2) = .30), with each making a significant contribution. Although the executive measures correlated with each other, the RSPAN did not correlate with tracking. The correlation between OSPAN and tracking was similar in magnitude to that between digit span and tracking (p < .05 for both), and when regression was used to partial out shared variance between the two tests, the remaining variance predicted by the OSPAN was minimal (sr ( 2 ) = .029). When measures of spatial memory were included in the regression, the unique variance predicted by the OSPAN became negligible (sr ( 2 ) = .000004). This suggests that the executive, as measured by tests such as the OSPAN, plays little role in explaining individual differences in multiple-object tracking.

  6. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  7. The wavelength frame multiplication chopper system for the ESS test beamline at the BER II reactor—A concept study of a fundamental ESS instrument principle

    International Nuclear Information System (INIS)

    Strobl, M.; Bulat, M.; Habicht, K.

    2013-01-01

    Contributing to the design update phase of the European Spallation Source ESS–scheduled to start operation in 2019–a test beamline is under construction at the BER II research reactor at Helmholtz Zentrum Berlin (HZB). This beamline offers experimental test capabilities of instrument concepts viable for the ESS. The experiments envisaged at this dedicated beamline comprise testing of components as well as of novel experimental approaches and methods taking advantage of the long pulse characteristic of the ESS source. Therefore the test beamline will be equipped with a sophisticated chopper system that provides the specific time structure of the ESS and enables variable wavelength resolutions via wavelength frame multiplication (WFM), a fundamental instrument concept beneficial for a number of instruments at ESS. We describe the unique chopper system developed for these purposes, which allows constant wavelength resolution for a wide wavelength band. Furthermore we discuss the implications for the conceptual design for related instrumentation at the ESS

  8. A new multiple channel data recording system for mechanised ultrasonic testing of pipes and nozzles by A-scan processing

    International Nuclear Information System (INIS)

    Heumueller, R.; Rathgeb, W.; Szafarska, E.; Bertus, N.; Erhard, A.; Montag, H.J.; Wuestenberg, H.

    1989-01-01

    A system of equipment for ultrasonic testing in nuclear technique is introduced. This is a four channel ultrasonic equipment, which consists of a manipulator suitable for components, up to four conventional test heads, a test head connection box connected with them via 20 metres of coaxial cable, a documentation unit for signal detection and conversion, a data collection computer for parametricising the equipment, measurement display and representation and a disc memory. The advantages of this test system lie in its easy use because of the compact equipment dimensions, in the data collection of the complete A picture by the documentation unit and in the flexible evaluation of the collected data by the computer. (MM) [de

  9. High power testing of the multiple-loop radio-frequency drive concept for the FMIT accelerator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Patton, R.D.

    1984-04-01

    The Fusion Materials Irradiation Test (FMIT) accelerator requires several 600-kW rf systems to simultaneously supply rf power to a single accelerator tank. Each rf-system output must be carefully phase and amplitude controlled to achieve the proper system performance. Two 80-MHz, 600-kW rf amplifiers with phase- and amplitude-control systems have been tested into a single, high-Q resonant cavity. Experimental results are presented

  10. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  11. Alpha test results for a Housing First eLearning strategy: the value of multiple qualitative methods for intervention design.

    Science.gov (United States)

    Ahonen, Emily Q; Watson, Dennis P; Adams, Erin L; McGuire, Alan

    2017-01-01

    Detailed descriptions of implementation strategies are lacking, and there is a corresponding dearth of information regarding methods employed in implementation strategy development. This paper describes methods and findings related to the alpha testing of eLearning modules developed as part of the Housing First Technical Assistance and Training (HFTAT) program's development. Alpha testing is an approach for improving the quality of a product prior to beta (i.e., real world) testing with potential applications for intervention development. Ten participants in two cities tested the modules. We collected data through (1) a structured log where participants were asked to record their experiences as they worked through the modules; (2) a brief online questionnaire delivered at the end of each module; and (3) focus groups. The alpha test provided useful data related to the acceptability and feasibility of eLearning as an implementation strategy, as well as identifying a number of technical issues and bugs. Each of the qualitative methods used provided unique and valuable information. In particular, logs were the most useful for identifying technical issues, and focus groups provided high quality data regarding how the intervention could best be used as an implementation strategy. Alpha testing was a valuable step in intervention development, providing us an understanding of issues that would have been more difficult to address at a later stage of the study. As a result, we were able to improve the modules prior to pilot testing of the entire HFTAT. Researchers wishing to alpha test interventions prior to piloting should balance the unique benefits of different data collection approaches with the need to minimize burdens for themselves and participants.

  12. Evaluation of three rapid oral fluid test devices on the screening of multiple drugs of abuse including ketamine.

    Science.gov (United States)

    Tang, Magdalene H Y; Ching, C K; Poon, Simon; Chan, Suzanne S S; Ng, W Y; Lam, M; Wong, C K; Pao, Ronnie; Lau, Angus; Mak, Tony W L

    2018-05-01

    Rapid oral fluid testing (ROFT) devices have been extensively evaluated for their ability to detect common drugs of abuse; however, the performance of such devices on simultaneous screening for ketamine has been scarcely investigated. The present study evaluated three ROFT devices (DrugWipe ® 6S, Ora-Check ® and SalivaScreen ® ) on the detection of ketamine, opiates, methamphetamine, cannabis, cocaine and MDMA. A liquid chromatography tandem mass spectrometry (LCMS) assay was firstly established and validated for confirmation analysis of the six types of drugs and/or their metabolites. In the field test, the three ROFT devices were tested on subjects recruited from substance abuse clinics/rehabilitation centre. Oral fluid was also collected using Quantisal ® for confirmation analysis. A total of 549 samples were collected in the study. LCMS analysis on 491 samples revealed the following drugs: codeine (55%), morphine (49%), heroin (40%), methamphetamine (35%), THC (8%), ketamine (4%) and cocaine (2%). No MDMA-positive cases were observed. Results showed that the overall specificity and accuracy were satisfactory and met the DRUID standard of >80% for all 3 devices. Ora-Check ® had poor sensitivities (ketamine 36%, methamphetamine 63%, opiates 53%, cocaine 60%, THC 0%). DrugWipe ® 6S showed good sensitivities in the methamphetamine (83%) and opiates (93%) tests but performed relatively poorly for ketamine (41%), cocaine (43%) and THC (22%). SalivaScreen ® also demonstrated good sensitivities in the methamphetamine (83%) and opiates (100%) tests, and had the highest sensitivity for ketamine (76%) and cocaine (71%); however, it failed to detect any of the 28 THC-positive cases. The test completion rate (proportion of tests completed with quality control passed) were: 52% (Ora-Check ® ), 78% (SalivaScreen ® ) and 99% (DrugWipe ® 6S). Copyright © 2018 Elsevier B.V. All rights reserved.

  13. A MULTIPLE TESTING OF THE ABC METHOD AND THE DEVELOPMENT OF A SECOND-GENERATION MODEL. PART II, TEST RESULTS AND AN ANALYSIS OF RECALL RATIO.

    Science.gov (United States)

    ALTMANN, BERTHOLD

    AFTER A BRIEF SUMMARY OF THE TEST PROGRAM (DESCRIBED MORE FULLY IN LI 000 318), THE STATISTICAL RESULTS TABULATED AS OVERALL "ABC (APPROACH BY CONCEPT)-RELEVANCE RATIOS" AND "ABC-RECALL FIGURES" ARE PRESENTED AND REVIEWED. AN ABSTRACT MODEL DEVELOPED IN ACCORDANCE WITH MAX WEBER'S "IDEALTYPUS" ("DIE OBJEKTIVITAET…

  14. EPS Mid-Career Award 2011. Are there multiple memory systems? Tests of models of implicit and explicit memory.

    Science.gov (United States)

    Shanks, David R; Berry, Christopher J

    2012-01-01

    This article reviews recent work aimed at developing a new framework, based on signal detection theory, for understanding the relationship between explicit (e.g., recognition) and implicit (e.g., priming) memory. Within this framework, different assumptions about sources of memorial evidence can be framed. Application to experimental results provides robust evidence for a single-system model in preference to multiple-systems models. This evidence comes from several sources including studies of the effects of amnesia and ageing on explicit and implicit memory. The framework allows a range of concepts in current memory research, such as familiarity, recollection, fluency, and source memory, to be linked to implicit memory. More generally, this work emphasizes the value of modern computational modelling techniques in the study of learning and memory.

  15. gsSKAT: Rapid gene set analysis and multiple testing correction for rare-variant association studies using weighted linear kernels.

    Science.gov (United States)

    Larson, Nicholas B; McDonnell, Shannon; Cannon Albright, Lisa; Teerlink, Craig; Stanford, Janet; Ostrander, Elaine A; Isaacs, William B; Xu, Jianfeng; Cooney, Kathleen A; Lange, Ethan; Schleutker, Johanna; Carpten, John D; Powell, Isaac; Bailey-Wilson, Joan E; Cussenot, Olivier; Cancel-Tassin, Geraldine; Giles, Graham G; MacInnis, Robert J; Maier, Christiane; Whittemore, Alice S; Hsieh, Chih-Lin; Wiklund, Fredrik; Catalona, William J; Foulkes, William; Mandal, Diptasri; Eeles, Rosalind; Kote-Jarai, Zsofia; Ackerman, Michael J; Olson, Timothy M; Klein, Christopher J; Thibodeau, Stephen N; Schaid, Daniel J

    2017-05-01

    Next-generation sequencing technologies have afforded unprecedented characterization of low-frequency and rare genetic variation. Due to low power for single-variant testing, aggregative methods are commonly used to combine observed rare variation within a single gene. Causal variation may also aggregate across multiple genes within relevant biomolecular pathways. Kernel-machine regression and adaptive testing methods for aggregative rare-variant association testing have been demonstrated to be powerful approaches for pathway-level analysis, although these methods tend to be computationally intensive at high-variant dimensionality and require access to complete data. An additional analytical issue in scans of large pathway definition sets is multiple testing correction. Gene set definitions may exhibit substantial genic overlap, and the impact of the resultant correlation in test statistics on Type I error rate control for large agnostic gene set scans has not been fully explored. Herein, we first outline a statistical strategy for aggregative rare-variant analysis using component gene-level linear kernel score test summary statistics as well as derive simple estimators of the effective number of tests for family-wise error rate control. We then conduct extensive simulation studies to characterize the behavior of our approach relative to direct application of kernel and adaptive methods under a variety of conditions. We also apply our method to two case-control studies, respectively, evaluating rare variation in hereditary prostate cancer and schizophrenia. Finally, we provide open-source R code for public use to facilitate easy application of our methods to existing rare-variant analysis results. © 2017 WILEY PERIODICALS, INC.

  16. Normalized Rotational Multiple Yield Surface Framework (NRMYSF) stress-strain curve prediction method based on small strain triaxial test data on undisturbed Auckland residual clay soils

    Science.gov (United States)

    Noor, M. J. Md; Ibrahim, A.; Rahman, A. S. A.

    2018-04-01

    Small strain triaxial test measurement is considered to be significantly accurate compared to the external strain measurement using conventional method due to systematic errors normally associated with the test. Three submersible miniature linear variable differential transducer (LVDT) mounted on yokes which clamped directly onto the soil sample at equally 120° from the others. The device setup using 0.4 N resolution load cell and 16 bit AD converter was capable of consistently resolving displacement of less than 1µm and measuring axial strains ranging from less than 0.001% to 2.5%. Further analysis of small strain local measurement data was performed using new Normalized Multiple Yield Surface Framework (NRMYSF) method and compared with existing Rotational Multiple Yield Surface Framework (RMYSF) prediction method. The prediction of shear strength based on combined intrinsic curvilinear shear strength envelope using small strain triaxial test data confirmed the significant improvement and reliability of the measurement and analysis methods. Moreover, the NRMYSF method shows an excellent data prediction and significant improvement toward more reliable prediction of soil strength that can reduce the cost and time of experimental laboratory test.

  17. Identification of multiple genetic loci in the mouse controlling immobility time in the tail suspension and forced swimming tests.

    Science.gov (United States)

    Abou-Elnaga, Ahmed F; Torigoe, Daisuke; Fouda, Mohamed M; Darwish, Ragab A; Abou-Ismail, Usama A; Morimatsu, Masami; Agui, Takashi

    2015-05-01

    Depression is one of the most famous psychiatric disorders in humans in all over the countries and considered a complex neurobehavioral trait and difficult to identify causal genes. Tail suspension test (TST) and forced swimming test (FST) are widely used for assessing depression-like behavior and antidepressant activity in mice. A variety of antidepressant agents are known to reduce immobility time in both TST and FST. To identify genetic determinants of immobility duration in both tests, we analyzed 101 F2 mice from an intercross between C57BL/6 and DBA/2 strains. Quantitative trait locus (QTL) mapping using 106 microsatellite markers revealed three loci (two significant and one suggestive) and five suggestive loci controlling immobility time in the TST and FST, respectively. Results of QTL analysis suggest a broad description of the genetic architecture underlying depression, providing underpinnings for identifying novel molecular targets for antidepressants to clear the complex genetic mechanisms of depressive disorders.

  18. Reasons for never and intermittent completion of colorectal cancer screening after receiving multiple rounds of mailed fecal tests.

    Science.gov (United States)

    Green, Beverly B; BlueSpruce, June; Tuzzio, Leah; Vernon, Sally W; Aubree Shay, L; Catz, Sheryl L

    2017-05-30

    Long-term adherence to colorectal cancer (CRC) screening is particularly important for fecal testing. Some U.S. studies report that only 25% of individuals repeat fecal testing annually. The purpose of this qualitative study was to identify barriers and facilitators reported by patients with suboptimal screening adherence to refine interventions for starting ongoing adherence to CRC screening. We also explored whether participants, particularly never screeners, would be willing to do a CRC screening blood test. Forty-one patients who previously enrolled in the Systems of Support to Increase CRC Screening (SOS) trial were interviewed 4-5 years later. Participants were purposively selected to include men and women with diverse race/ethnicities who had either been inconsistent screeners or had never screened during the first three years of SOS despite receiving at least two rounds of mailed fecal tests. Two interviewers conducted 30-min telephone interviews using a semi-structured interview guide. An iterative thematic analysis approach was used. Themes related to screening barriers were more pervasive among never screeners including: (1) Avoidance (inattention, procrastination) (2) Concerns about handling stool; (3) Health concerns; (4) Fear of a cancer diagnosis or positive test results. Themes related to screening facilitators were more often mentioned by participants who screened at least once including: (1) Use of a simpler 1-sample fecal test; (2) Convenience of mailings and doing the test at home; (3) Salience of prevention, especially as one got older; and (4) Influence of recommendations from providers, family and friends. Participants had diverse preferences for the number (3 on average) and types (phone, mail, text) of screening reminders. Some participants did not prefer e-mail links to the patient shared electronic health record because of difficulties remembering their password. It was acceptable for a nurse or medical assistant not from their clinic to

  19. The Test Matters: The Relationship between Classroom Observation Scores and Teacher Value Added on Multiple Types of Assessment

    Science.gov (United States)

    Grossman, Pam; Cohen, Julie; Ronfeldt, Matthew; Brown, Lindsay

    2014-01-01

    In this study, we examined how the relationships between one observation protocol, the Protocol for Language Arts Teaching Observation (PLATO), and value-added measures shift when different tests are used to assess student achievement. Using data from the Measures of Effective Teaching Project, we found that PLATO was more strongly related to the…

  20. catcher: A Software Program to Detect Answer Copying in Multiple-Choice Tests Based on Nominal Response Model

    Science.gov (United States)

    Kalender, Ilker

    2012-01-01

    catcher is a software program designed to compute the [omega] index, a common statistical index for the identification of collusions (cheating) among examinees taking an educational or psychological test. It requires (a) responses and (b) ability estimations of individuals, and (c) item parameters to make computations and outputs the results of…

  1. Multiple Intelligence Scores of Science Stream Students and Their Relation with Reading Competency in Malaysian University English Test (MUET)

    Science.gov (United States)

    Razak, Norizan Abdul; Zaini, Nuramirah

    2014-01-01

    Many researches have shown that different approach needed in analysing linear and non-linear reading comprehension texts and different cognitive skills are required. This research attempts to discover the relationship between Science Stream students' reading competency on linear and non-linear texts in Malaysian University English Test (MUET) with…

  2. A Multiple Mediational Test of the Relationship between Childhood Maltreatment and Non-Suicidal Self-Injury

    Science.gov (United States)

    Shenk, Chad E.; Noll, Jennie G.; Cassarly, Jennifer A.

    2010-01-01

    Post-traumatic stress symptoms, depressive symptoms, and psychological dysregulation have been shown to mediate the relationship between child maltreatment and non-suicidal self-injury. However, these proposed mediators often co-occur and previous research has not tested mediation when all variables are assessed simultaneously. The current study…

  3. Results of testing the E9 multiple probe lateral logging device in deep wells in the eastern Pre-caucasus

    Energy Technology Data Exchange (ETDEWEB)

    Boyarchuk, A.F.; Kochetkov, V.T.; Kucherov, R.A.

    1981-07-01

    The integrated lateral logging device E9 developed for investigating deep and extra-deep wells, permitting measurement of apparent resistances by three probes at different depths, is described. It is heat and pressure resistant (up to 200/degree/C, 120 MPa). The tests showed that under certain favorable conditions the device is fairly effective.

  4. Multiple Irradiation Capsule Experiment (MICE)-3B Irradiation Test of Space Fuel Specimens in the Advanced Test Reactor (ATR) - Close Out Documentation for Naval Reactors (NR) Information

    Energy Technology Data Exchange (ETDEWEB)

    M. Chen; CM Regan; D. Noe

    2006-01-09

    Few data exist for UO{sub 2} or UN within the notional design space for the Prometheus-1 reactor (low fission rate, high temperature, long duration). As such, basic testing is required to validate predictions (and in some cases determine) performance aspects of these fuels. Therefore, the MICE-3B test of UO{sub 2} pellets was designed to provide data on gas release, unrestrained swelling, and restrained swelling at the upper range of fission rates expected for a space reactor. These data would be compared with model predictions and used to determine adequacy of a space reactor design basis relative to fission gas release and swelling of UO{sub 2} fuel and to assess potential pellet-clad interactions. A primary goal of an irradiation test for UN fuel was to assess performance issues currently associated with this fuel type such as gas release, swelling and transient performance. Information learned from this effort may have enabled use of UN fuel for future applications.

  5. Flight Test Evaluation of an Unmanned Aircraft System Traffic Management (UTM) Concept for Multiple Beyond-Visual-Line-of-Sight (BVLOS) Operations

    Science.gov (United States)

    Johnson, Marcus; Jung, Jaewoo; Rios, Joseph; Mercer, Joey; Homola, Jeffrey; Prevot, Thomas; Mulfinger, Daniel; Kopardekar, Parimal

    2017-01-01

    This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.

  6. Flight Test Evaluation of an Unmanned Aircraft System Traffic Management (UTM) Concept for Multiple Beyond-Visual-Line-of-Sight Operations

    Science.gov (United States)

    Johnson, Marcus; Jung, Jaewoo; Rios, Joseph; Mercer, Joey; Homola, Jeffrey; Prevot, Thomas; Mulfinger, Daniel; Kopardekar, Parimal

    2017-01-01

    This study evaluates a traffic management concept designed to enable simultaneous operations of multiple small unmanned aircraft systems (UAS) in the national airspace system (NAS). A five-day flight-test activity is described that examined the feasibility of operating multiple UAS beyond visual line of sight (BVLOS) of their respective operators in the same airspace. Over the five-day campaign, three groups of five flight crews operated a total of eleven different aircraft. Each group participated in four flight scenarios involving five simultaneous missions. Each vehicle was operated BVLOS up to 1.5 miles from the pilot in command. Findings and recommendations are presented to support the feasibility and safety of routine BVLOS operations for small UAS.

  7. Assessment of cognition using the Rao's Brief Repeatable Battery of Neuropsychological Tests on a group of Brazilian patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Joseph Bruno Bidin Brooks

    2011-12-01

    Full Text Available To assess the cognition of patients with multiple sclerosis (MS using the Rao's Brief Repeatable Battery of Neuropsychological Tests (BRB-N. METHOD: BRB-N was translated and adapted for control subjects. Subsequently, it was applied to a group of patients with relapsing-remitting (RR MS. RESULTS: The assessment on the healthy controls (n=47 showed that the correlation between tests on the same cognitive domain was high and that there was a five-factor solution that explained 90% of the total variance. Except for the Word List Generation subset of tests, the performance of patients with RRMS (n=39 was worse than that of the healthy controls. CONCLUSION: BRB-N is a relatively simple method to assess cognition of patients with MS in the daily clinic. It does not take long to apply and does not require special skills or equipment.

  8. Capture-based next-generation sequencing reveals multiple actionable mutations in cancer patients failed in traditional testing.

    Science.gov (United States)

    Xie, Jing; Lu, Xiongxiong; Wu, Xue; Lin, Xiaoyi; Zhang, Chao; Huang, Xiaofang; Chang, Zhili; Wang, Xinjing; Wen, Chenlei; Tang, Xiaomei; Shi, Minmin; Zhan, Qian; Chen, Hao; Deng, Xiaxing; Peng, Chenghong; Li, Hongwei; Fang, Yuan; Shao, Yang; Shen, Baiyong

    2016-05-01

    Targeted therapies including monoclonal antibodies and small molecule inhibitors have dramatically changed the treatment of cancer over past 10 years. Their therapeutic advantages are more tumor specific and with less side effects. For precisely tailoring available targeted therapies to each individual or a subset of cancer patients, next-generation sequencing (NGS) has been utilized as a promising diagnosis tool with its advantages of accuracy, sensitivity, and high throughput. We developed and validated a NGS-based cancer genomic diagnosis targeting 115 prognosis and therapeutics relevant genes on multiple specimen including blood, tumor tissue, and body fluid from 10 patients with different cancer types. The sequencing data was then analyzed by the clinical-applicable analytical pipelines developed in house. We have assessed analytical sensitivity, specificity, and accuracy of the NGS-based molecular diagnosis. Also, our developed analytical pipelines were capable of detecting base substitutions, indels, and gene copy number variations (CNVs). For instance, several actionable mutations of EGFR,PIK3CA,TP53, and KRAS have been detected for indicating drug susceptibility and resistance in the cases of lung cancer. Our study has shown that NGS-based molecular diagnosis is more sensitive and comprehensive to detect genomic alterations in cancer, and supports a direct clinical use for guiding targeted therapy.

  9. Combining Multiple Hypothesis Testing with Machine Learning Increases the Statistical Power of Genome-wide Association Studies

    Science.gov (United States)

    Mieth, Bettina; Kloft, Marius; Rodríguez, Juan Antonio; Sonnenburg, Sören; Vobruba, Robin; Morcillo-Suárez, Carlos; Farré, Xavier; Marigorta, Urko M.; Fehr, Ernst; Dickhaus, Thorsten; Blanchard, Gilles; Schunk, Daniel; Navarro, Arcadi; Müller, Klaus-Robert

    2016-01-01

    The standard approach to the analysis of genome-wide association studies (GWAS) is based on testing each position in the genome individually for statistical significance of its association with the phenotype under investigation. To improve the analysis of GWAS, we propose a combination of machine learning and statistical testing that takes correlation structures within the set of SNPs under investigation in a mathematically well-controlled manner into account. The novel two-step algorithm, COMBI, first trains a support vector machine to determine a subset of candidate SNPs and then performs hypothesis tests for these SNPs together with an adequate threshold correction. Applying COMBI to data from a WTCCC study (2007) and measuring performance as replication by independent GWAS published within the 2008–2015 period, we show that our method outperforms ordinary raw p-value thresholding as well as other state-of-the-art methods. COMBI presents higher power and precision than the examined alternatives while yielding fewer false (i.e. non-replicated) and more true (i.e. replicated) discoveries when its results are validated on later GWAS studies. More than 80% of the discoveries made by COMBI upon WTCCC data have been validated by independent studies. Implementations of the COMBI method are available as a part of the GWASpi toolbox 2.0. PMID:27892471

  10. Multiple Genetic Analysis System-Based Antibiotic Susceptibility Testing in Helicobacter pylori and High Eradication Rate With Phenotypic Resistance-Guided Quadruple Therapy.

    Science.gov (United States)

    Dong, Fangyuan; Ji, Danian; Huang, Renxiang; Zhang, Fan; Huang, Yiqin; Xiang, Ping; Kong, Mimi; Nan, Li; Zeng, Xianping; Wu, Yong; Bao, Zhijun

    2015-11-01

    Antibiotics resistance in Helicobacter pylori (H. pylori) is the major factor for eradication failure. Molecular tests including fluorescence in situ hybridization, PCR-restriction fragment length polymorphism, and dual priming oligonucleotide-PCR (DPO-PCR) play critical roles in the detection of antibiotic susceptibility; however, limited knowledge is known about application of multiple genetic analysis system (MGAS) in the area of H. pylori identification and antibiotics resistance detection.The aim of this study is to determine the antibiotics resistance using different molecular tests and evaluate the treatment outcomes of E-test-based genotypic resistance.A total of 297 patients with dyspepsia complaint were recruited for gastroscopies. Ninety patients with H. pylori culture positive were randomly divided into 2 groups (test group and control group). E-test, general PCR, and MGAS assay were performed in test group. Patients in control group were treated with empirical therapy (rabeprazole + bismuth potassium citrate + amoxicillin [AMX] + clarithromycin [CLR]), whereas patients in test group received quadruple therapy based on E-test results twice daily for 14 consecutive days. The eradication effect of H. pylori was confirmed by C-urea breath test after at least 4 weeks when treatment was finished.Rapid urease test showed 46.5% (128/297) patients with H. pylori infection, whereas 30.3% (90/297) patients were H. pylori culture positive. E-test showed that H. pylori primary resistance rate to CLR, AMX, metronidazole, tetracycline, and levofloxacin (LVX) was 40.0% (18/45), 4.4% (2/45), 53.3% (24/45), 0% (0/45), and 55.6% (25/45), respectively. In addition, there are many multidrug resistant (MDR) phenotypes, and the MDR strains have higher minimum inhibitory concentration than their single-drug resistant counterparts. Considering E-test as the reference test, the sensitivities of general PCR and MGAS in detecting CLR resistance were 83.3% (15/18) and 94.4% (17

  11. Evaluation of a multiple-encounter in situ simulation for orientation of staff to a new paediatric emergency service: a single-group pretest/post-test study.

    Science.gov (United States)

    Davison, Michelle; Kinnear, Frances B; Fulbrook, Paul

    2017-10-01

    To assess the utility of a multiple-encounter in-situ (MEIS) simulation as an orientation tool for multidisciplinary staff prior to opening a new paediatric emergency service. A single-group pretest/post-test study was conducted. During the MEIS simulation, multidisciplinary staff with participant or observer roles managed eight children (mannequins) who attended triage with their parent/guardians (clinical facilitators) for a range of emergency presentations (structured scenarios designed to represent the expected range of presentations plus test various clinical pathways/systems). Participants were debriefed to explore clinical, systems and crisis-resource management issues. Participants also completed a pre-intervention and post-intervention questionnaire comprising statements about role confidence and orientation adequacy. Pre-test and post-test results were analysed using t-test and Wilcoxon signed rank test. Eighty-nine staff participated in the MEIS simulation, with the majority completing the pre-simulation and post-simulation questionnaire. There was a significant improvement in post-intervention versus pre-intervention Likert scores for role confidence and orientation adequacy (p=0.001 and orientation adequacy. Nearly all scenarios resulted in significant increases in participants' confidence levels. The MEIS simulation was of utility in orientation of staff, at least with respect to self-reported role confidence and orientation adequacy. Its effectiveness in practice or compared with other orientation techniques was not assessed, but it did identify several flaws in planned systems allowing remediation prior to opening.

  12. Hydraulic characterization of volcanic rocks in Pahute Mesa using an integrated analysis of 16 multiple-well aquifer tests, Nevada National Security Site, 2009–14

    Science.gov (United States)

    Garcia, C. Amanda; Jackson, Tracie R.; Halford, Keith J.; Sweetkind, Donald S.; Damar, Nancy A.; Fenelon, Joseph M.; Reiner, Steven R.

    2017-01-20

    An improved understanding of groundwater flow and radionuclide migration downgradient from underground nuclear-testing areas at Pahute Mesa, Nevada National Security Site, requires accurate subsurface hydraulic characterization. To improve conceptual models of flow and transport in the complex hydrogeologic system beneath Pahute Mesa, the U.S. Geological Survey characterized bulk hydraulic properties of volcanic rocks using an integrated analysis of 16 multiple-well aquifer tests. Single-well aquifer-test analyses provided transmissivity estimates at pumped wells. Transmissivity estimates ranged from less than 1 to about 100,000 square feet per day in Pahute Mesa and the vicinity. Drawdown from multiple-well aquifer testing was estimated and distinguished from natural fluctuations in more than 200 pumping and observation wells using analytical water-level models. Drawdown was detected at distances greater than 3 miles from pumping wells and propagated across hydrostratigraphic units and major structures, indicating that neither faults nor structural blocks noticeably impede or divert groundwater flow in the study area.Consistent hydraulic properties were estimated by simultaneously interpreting drawdown from the 16 multiple-well aquifer tests with an integrated groundwater-flow model composed of 11 well-site models—1 for each aquifer test site. Hydraulic properties were distributed across volcanic rocks with the Phase II Pahute Mesa-Oasis Valley Hydrostratigraphic Framework Model. Estimated hydraulic-conductivity distributions spanned more than two orders of magnitude in hydrostratigraphic units. Overlapping hydraulic conductivity ranges among units indicated that most Phase II Hydrostratigraphic Framework Model units were not hydraulically distinct. Simulated total transmissivity ranged from 1,600 to 68,000 square feet per day for all pumping wells analyzed. High-transmissivity zones exceeding 10,000 square feet per day exist near caldera margins and extend

  13. Computer-aided design of multifrequency eddy-current tests for layered conductors with multiple property variations

    Energy Technology Data Exchange (ETDEWEB)

    Deeds, W E; Dodd, C V; Scott, G W

    1979-10-01

    Our program is part of a larger project designed to develop multifrequency eddy-current inspection techniques for multilayered conductors with parallel planar boundaries. To reduce the need to specially program each new problem, a family of programs that handle a large class of related problems with only minor editorial and interactive changes were developed. Programs for two types of cylindrical coil probes were developed: the reflection probe, which contains the driver and pickup coils and is used from one side of the specimen, and the through-transmission probe set, which places the driver and pickup coils on opposite sides of the conductor stack. The programs perform the following basic functions: (1) simulation of an ideal instrument's response to specific conductor and defect configurations, (2) control of an eddy-current instrument interfaced to a minicomputer to acquire and record actual instrument responses to test specimens, (3) construction of complex function expansions to relate instrument response to conductor and defect properties by using measured or computed responses and properties, and (4) simulation of a microcomputer on board the instrument by the interfaced minicomputer to test the analytical programming for the microcomputer. The report contains the basic equations for the computations, the main and subroutine programs, instructions for editorial changes and program execution, analyses of the main programs, file requirements, and other miscellaneous aids for the user.

  14. Multistage treadmill exercise testing with a multiple unipolar precordial lead system in the evaluation of effort angina pectoris

    International Nuclear Information System (INIS)

    Shiki, Kazuhito; Tsuzuki, Masato; Kawai, Naoki; Kondo, Teruo; Sotobata, Iwao

    1984-01-01

    Sixty-one patients who had angina pectoris without prior myocardial infarction and 24 healthy men were studied by multistage treadmill exercise testing with 20 unipolar leads covering the left anterolateral hemithorax. Exercise-induced ST- segment changes were compared with the results of stress thallium-201 myocardial images and also with coronary arteriographic fingings. All patients had more than 75% narrowing of at least one major coronary artery. Fifty-one of the 61 patients had diagnostically significant exercise-induced ischemic ST-segment depression (sensitivity 83.6%) and all of the 24 controls showed a negative exercise test (specificity 100%). The exercise-induced ST-segment depressions appeared most often in the area just below V 5 . The number of leads with ST-segment depression and the sum of the depths of ST-segment depressions significantly correlated with the number of regions-of-interest of stress-induced hypoperfusion of myocardial scintigraphy (r = 0.62 and r = 0.61, respectively). These parameters increased as the number of diseased coronary arteries increased, but were not influenced by the presence or absence of coronary collateral circulation. The maximum depth of ST-segment depression was greater in triple vessel disease than in single or double vessel disease (p 5 . (J.P.N.)

  15. No trade-off between learning speed and associative flexibility in bumblebees: a reversal learning test with multiple colonies.

    Directory of Open Access Journals (Sweden)

    Nigel E Raine

    Full Text Available Potential trade-offs between learning speed and memory-related performance could be important factors in the evolution of learning. Here, we test whether rapid learning interferes with the acquisition of new information using a reversal learning paradigm. Bumblebees (Bombus terrestris were trained to associate yellow with a floral reward. Subsequently the association between colour and reward was reversed, meaning bees then had to learn to visit blue flowers. We demonstrate that individuals that were fast to learn yellow as a predictor of reward were also quick to reverse this association. Furthermore, overnight memory retention tests suggest that faster learning individuals are also better at retaining previously learned information. There is also an effect of relatedness: colonies whose workers were fast to learn the association between yellow and reward also reversed this association rapidly. These results are inconsistent with a trade-off between learning speed and the reversal of a previously made association. On the contrary, they suggest that differences in learning performance and cognitive (behavioural flexibility could reflect more general differences in colony learning ability. Hence, this study provides additional evidence to support the idea that rapid learning and behavioural flexibility have adaptive value.

  16. Multiple Continental Radiations and Correlates of Diversification in Lupinus (Leguminosae): Testing for Key Innovation with Incomplete Taxon Sampling

    Science.gov (United States)

    Drummond, Christopher S.; Eastwood, Ruth J.; Miotto, Silvia T. S.; Hughes, Colin E.

    2012-01-01

    Replicate radiations provide powerful comparative systems to address questions about the interplay between opportunity and innovation in driving episodes of diversification and the factors limiting their subsequent progression. However, such systems have been rarely documented at intercontinental scales. Here, we evaluate the hypothesis of multiple radiations in the genus Lupinus (Leguminosae), which exhibits some of the highest known rates of net diversification in plants. Given that incomplete taxon sampling, background extinction, and lineage-specific variation in diversification rates can confound macroevolutionary inferences regarding the timing and mechanisms of cladogenesis, we used Bayesian relaxed clock phylogenetic analyses as well as MEDUSA and BiSSE birth–death likelihood models of diversification, to evaluate the evolutionary patterns of lineage accumulation in Lupinus. We identified 3 significant shifts to increased rates of net diversification (r) relative to background levels in the genus (r = 0.18–0.48 lineages/myr). The primary shift occurred approximately 4.6 Ma (r = 0.48–1.76) in the montane regions of western North America, followed by a secondary shift approximately 2.7 Ma (r = 0.89–3.33) associated with range expansion and diversification of allopatrically distributed sister clades in the Mexican highlands and Andes. We also recovered evidence for a third independent shift approximately 6.5 Ma at the base of a lower elevation eastern South American grassland and campo rupestre clade (r = 0.36–1.33). Bayesian ancestral state reconstructions and BiSSE likelihood analyses of correlated diversification indicated that increased rates of speciation are strongly associated with the derived evolution of perennial life history and invasion of montane ecosystems. Although we currently lack hard evidence for “replicate adaptive radiations” in the sense of convergent morphological and ecological trajectories among species in different

  17. Development and performance test of a system available for generating multiple extreme conditions for neutron scattering experiments

    International Nuclear Information System (INIS)

    Kawano, Shinji; Fukui, Susumu; Moriai, Atsushi; Ohtomo, Akitoshi; Ichimura, Shigeki; Onodera, Akifumi; Amita, F.; Katano, Susumu

    1998-01-01

    We have developed unique system available for controlling sample environment during the neutron scattering experiments. The system can simultaneously generate triple extreme conditions of low temperature, high magnetic field and high pressure. The system consists of: (i) a liquid-helium cryostat variable for sample temperature from 1.7 K to 200 K, (ii) a superconducting magnet providing a vertical field up to ±5 T with an antisymmetric split-coil geometry for polarized-beam experiments, and (iii) a non-magnetic piston-cylinder high-pressure cell designed with the aim of generating hydrostatic pressure up to 2.5 GPa. In the presentation, we will report the outline of the system and some results of performance tests at KURRI and JRR-3M of JAERI. (author)

  18. High prevalence of normal tests assessing hypercortisolism in subjects with mild and episodic Cushing's syndrome suggests that the paradigm for diagnosis and exclusion of Cushing's syndrome requires multiple testing.

    Science.gov (United States)

    Friedman, T C; Ghods, D E; Shahinian, H K; Zachery, L; Shayesteh, N; Seasholtz, S; Zuckerbraun, E; Lee, M L; McCutcheon, I E

    2010-11-01

    Many Endocrinologists believe that a single determination of eucortisolism or a single demonstration of appropriate suppression to dexamethasone excluded Cushing's syndrome, except in what was previously thought to be the rare patient with episodic or periodic Cushing's syndrome. We hypothesize that episodic Cushing's syndrome is relatively common and a single test assessing hypercortisolism may not be sufficient to accurately rule out or diagnose Cushing's syndrome and retrospectively examined the number of normal and abnormal tests assessing hypercortisolism performed on multiple occasions in 66 patients found to have mild and/or episodic Cushing's syndrome compared to a similar group of 54 patients evaluated for, but determined not to have Cushing's syndrome. We found that 65 of the 66 patients with Cushing's syndrome had at least one normal test of cortisol status and most patients had several normal tests. The probability of having Cushing's syndrome when one test was negative was 92% for 23:00 h salivary cortisol, 88% for 24-h UFC, 86% for 24-h 17OHS, and 54% for nighttime plasma cortisol. These results demonstrated that episodic hypercortisolism is highly prevalent in subjects with mild Cushing's syndrome and no single test was effective in conclusively diagnosing or excluding the condition. Rather, the paradigm for the diagnosis should be a careful history and physical examination and in those patients in whom mild Cushing's syndrome/disease is strongly suspected, multiple tests assessing hypercortisolism should be performed on subsequent occasions, especially when the patient is experiencing signs and symptoms of short-term hypercortisolism. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  20. Flight Test Evaluation of an Unmanned Aircraft System Traffic Management (UTM) Concept for Multiple Beyond-Visual-Line-of-Sight (BVLOS) Operations

    Science.gov (United States)

    Johnson, Marcus; Jung, Jaewoo; Rios, Joseph; Mercer, Joey; Homola, Jeffrey; Prevot, Thomas; Mulfinger, Daniel; Kopardekar, Parimal

    2017-01-01

    Many applications of small Unmanned Aircraft System (UAS) have been envisioned. These include surveillance of key assets such as pipelines, rail, or electric wires, deliveries, search and rescue, traffic monitoring, videography, and precision agriculture. These operations are likely to occur in the same airspace in the presence of many static and dynamic constraints such as airports, and high wind areas. Therefore, operations of small UAS need to be managed to ensure safety and operation efficiency is maintained. NASA has advanced a concept for UAS Traffic Management (UTM) and has initiated a research effort to refine that concept and develop operational and system requirements. A UTM research platform is in development and flight test activities to evaluate core functions and key assumptions focusing exclusively on UAS operations in different environments are underway. This seminar will present lessons learned from a recent flight test focused on enabling operations of multiple UAS in lower-risk environments within and beyond visual line of sight (BVLOS).

  1. A multiple choice testing program coupled with a year-long elective experience is associated with improved performance on the internal medicine in-training examination.

    Science.gov (United States)

    Mathis, Bradley R; Warm, Eric J; Schauer, Daniel P; Holmboe, Eric; Rouan, Gregory W

    2011-11-01

    The Internal Medicine In-Training Exam (IM-ITE) assesses the content knowledge of internal medicine trainees. Many programs use the IM-ITE to counsel residents, to create individual remediation plans, and to make fundamental programmatic and curricular modifications. To assess the association between a multiple-choice testing program administered during 12 consecutive months of ambulatory and inpatient elective experience and IM-ITE percentile scores in third post-graduate year (PGY-3) categorical residents. Retrospective cohort study. One hundred and four categorical internal medicine residents. Forty-five residents in the 2008 and 2009 classes participated in the study group, and the 59 residents in the three classes that preceded the use of the testing program, 2005-2007, served as controls. A comprehensive, elective rotation specific, multiple-choice testing program and a separate board review program, both administered during a continuous long-block elective experience during the twelve months between the second post-graduate year (PGY-2) and PGY-3 in-training examinations. We analyzed the change in median individual percent correct and percentile scores between the PGY-1 and PGY-2 IM-ITE and between the PGY-2 and PGY-3 IM-ITE in both control and study cohorts. For our main outcome measure, we compared the change in median individual percentile rank between the control and study cohorts between the PGY-2 and the PGY-3 IM-ITE testing opportunities. After experiencing the educational intervention, the study group demonstrated a significant increase in median individual IM-ITE percentile score between PGY-2 and PGY-3 examinations of 8.5 percentile points (p ITE performance.

  2. Characterization of the nociceptin receptor (ORL-1) agonist, Ro64-6198, in tests of anxiety across multiple species.

    Science.gov (United States)

    Varty, G B; Hyde, L A; Hodgson, R A; Lu, S X; McCool, M F; Kazdoba, T M; Del Vecchio, R A; Guthrie, D H; Pond, A J; Grzelak, M E; Xu, X; Korfmacher, W A; Tulshian, D; Parker, E M; Higgins, G A

    2005-10-01

    Previous studies have demonstrated behaviors indicative of anxiolysis in rats pretreated with the nociceptin receptor (opioid receptor like-1, ORL-1) agonist, Ro64-6198. The aim of this study was to examine the effects of Ro64-6198 in anxiety models across three species: rat, guinea pig, and mouse. In addition, the receptor specificity of Ro64-6198 was studied, using the ORL-1 receptor antagonist, J-113397, and ORL-1 receptor knockout (KO) mice. Finally, neurological studies examined potential side effects of Ro64-6198 in the rat and mouse. Ro64-6198 (3-10 mg/kg) increased punished responding in a rat conditioned lick suppression test similarly to chlordiazepoxide (6 mg/kg). This effect of Ro64-6198 was attenuated by J-113397 (10 mg/kg), but not the mu opioid antagonist, naltrexone (3 mg/kg). In addition, Ro64-6198 (1-3 mg/kg) reduced isolation-induced vocalizations in rat and guinea pig pups. Ro64-6198 (3 mg/kg) increased the proportion of punished responding in a mouse Geller-Seifter test in wild-type (WT) but not ORL-1 KO mice, whereas diazepam (1-5.6 mg/kg) was effective in both genotypes. In rats, Ro64-6198 reduced locomotor activity (LMA) and body temperature and impaired rotarod, beam walking, and fixed-ratio (FR) performance at doses of 10-30 mg/kg, i.e., three to ten times higher than an anxiolytic dose. In WT mice, Ro64-6198 (3-10 mg/kg) reduced LMA and rotarod performance, body temperature, and FR responding, but these same measures were unaffected in ORL-1 KO mice. Haloperidol (0.3-3 mg/kg) reduced these measures to a similar extent in both genotypes. These studies confirm the potent, ORL-1 receptor-mediated, anxiolytic-like effects of Ro64-6198, extending the findings across three species. Ro64-6198 has target-based side effects, although the magnitude of these effects varies across species.

  3. Intra-tumoral Heterogeneity of KRAS and BRAF Mutation Status in Patients with Advanced Colorectal Cancer (aCRC and Cost-Effectiveness of Multiple Sample Testing

    Directory of Open Access Journals (Sweden)

    Susan D. Richman

    2011-01-01

    Full Text Available KRAS mutation status is established as a predictive biomarker of benefit from anti-EGFr therapies. Mutations are normally assessed using DNA extracted from one formalin-fixed, paraffin-embedded (FFPE tumor block. We assessed heterogeneity of KRAS and BRAF mutation status intra-tumorally (multiple blocks from the same primary tumor. We also investigated the utility and efficiency of genotyping a ‘DNA cocktail’ prepared from multiple blocks. We studied 68 consenting patients in two randomized clinical trials. DNA was extracted, from ≥2 primary tumor FFPE blocks per patient. DNA was genotyped by pyrosequencing for KRAS codons 12, 13 and 61 and BRAF codon 600. In patients with heterogeneous mutation status, DNA cocktails were prepared and genotyped. Among 69 primary tumors in 68 patients, 7 (10.1% showed intratumoral heterogeneity; 5 (7.2% at KRAS codons 12, 13 and 2 (2.9% at BRAF codon 600. In patients displaying heterogeneity, the relevant KRAS or BRAF mutation was also identified in ‘DNA cocktail’ samples when including DNA from mutant and wild-type blocks. Heterogeneity is uncommon but not insignificant. Testing DNA from a single block will wrongly assign wild-type status to 10% patients. Testing more than one block, or preferably preparation of a ‘DNA cocktail’ from two or more tumor blocks, improves mutation detection at minimal extra cost.

  4. Student certainty answering misconception question: study of Three-Tier Multiple-Choice Diagnostic Test in Acid-Base and Solubility Equilibrium

    Science.gov (United States)

    Ardiansah; Masykuri, M.; Rahardjo, S. B.

    2018-04-01

    Students’ concept comprehension in three-tier multiple-choice diagnostic test related to student confidence level. The confidence level related to certainty and student’s self-efficacy. The purpose of this research was to find out students’ certainty in misconception test. This research was quantitative-qualitative research method counting students’ confidence level. The research participants were 484 students that were studying acid-base and equilibrium solubility subject. Data was collected using three-tier multiple-choice (3TMC) with thirty questions and students’ questionnaire. The findings showed that #6 item gives the highest misconception percentage and high student confidence about the counting of ultra-dilute solution’s pH. Other findings were that 1) the student tendency chosen the misconception answer is to increase over item number, 2) student certainty decreased in terms of answering the 3TMC, and 3) student self-efficacy and achievement were related each other in the research. The findings suggest some implications and limitations for further research.

  5. Application of single-step genomic best linear unbiased prediction with a multiple-lactation random regression test-day model for Japanese Holsteins.

    Science.gov (United States)

    Baba, Toshimi; Gotoh, Yusaku; Yamaguchi, Satoshi; Nakagawa, Satoshi; Abe, Hayato; Masuda, Yutaka; Kawahara, Takayoshi

    2017-08-01

    This study aimed to evaluate a validation reliability of single-step genomic best linear unbiased prediction (ssGBLUP) with a multiple-lactation random regression test-day model and investigate an effect of adding genotyped cows on the reliability. Two data sets for test-day records from the first three lactations were used: full data from February 1975 to December 2015 (60 850 534 records from 2 853 810 cows) and reduced data cut off in 2011 (53 091 066 records from 2 502 307 cows). We used marker genotypes of 4480 bulls and 608 cows. Genomic enhanced breeding values (GEBV) of 305-day milk yield in all the lactations were estimated for at least 535 young bulls using two marker data sets: bull genotypes only and both bulls and cows genotypes. The realized reliability (R 2 ) from linear regression analysis was used as an indicator of validation reliability. Using only genotyped bulls, R 2 was ranged from 0.41 to 0.46 and it was always higher than parent averages. The very similar R 2 were observed when genotyped cows were added. An application of ssGBLUP to a multiple-lactation random regression model is feasible and adding a limited number of genotyped cows has no significant effect on reliability of GEBV for genotyped bulls. © 2016 Japanese Society of Animal Science.

  6. Utilized social support and self-esteem mediate the relationship between perceived social support and suicide ideation. A test of a multiple mediator model.

    Science.gov (United States)

    Kleiman, Evan M; Riskind, John H

    2013-01-01

    While perceived social support has received considerable research as a protective factor for suicide ideation, little attention has been given to the mechanisms that mediate its effects. We integrated two theoretical models, Joiner's (2005) interpersonal theory of suicide and Leary's (Leary, Tambor, Terdal, & Downs, 1995) sociometer theory of self-esteem to investigate two hypothesized mechanisms, utilization of social support and self-esteem. Specifically, we hypothesized that individuals must utilize the social support they perceive that would result in increased self-esteem, which in turn buffers them from suicide ideation. Participants were 172 college students who completed measures of social support, self-esteem, and suicide ideation. Tests of simple mediation indicate that utilization of social support and self-esteem may each individually help to mediate the perceived social support/suicide ideation relationship. Additionally, a test of multiple mediators using bootstrapping supported the hypothesized multiple-mediator model. The use of a cross-sectional design limited our ability to find true cause-and-effect relationships. Results suggested that utilized social support and self-esteem both operate as individual moderators in the social support/self-esteem relationship. Results further suggested, in a comprehensive model, that perceived social support buffers suicide ideation through utilization of social support and increases in self-esteem.

  7. Factorial structure of the 'ToM Storybooks': A test evaluating multiple components of Theory of Mind.

    Science.gov (United States)

    Bulgarelli, Daniela; Testa, Silvia; Molina, Paola

    2015-06-01

    This study examined the factorial structure of the Theory of Mind (ToM) Storybooks, a comprehensive 93-item instrument tapping the five components in Wellman's model of ToM (emotion recognition, understanding of desire and beliefs, ability to distinguish between physical and mental entities, and awareness of the link between perception and knowledge). A sample of 681 three- to eight-year-old Italian children was divided into three age groups to assess whether factorial structure varied across different age ranges. Partial credit model analysis was applied to the data, leading to the empirical identification of 23 composite variables aggregating the ToM Storybooks items. Confirmatory factor analysis was then conducted on the composite variables, providing support for the theoretical model. There were partial differences in the specific composite variables making up the dimensions for each of the three age groups. A single test evaluating distinct dimensions of ToM is a valuable resource for clinical practice which may be used to define differential profiles for specific populations. © 2014 The British Psychological Society.

  8. The study on defects in aluminum 2219-T6 thick butt friction stir welds with the application of multiple non-destructive testing methods

    International Nuclear Information System (INIS)

    Li, Bo; Shen, Yifu; Hu, Weiye

    2011-01-01

    Research highlights: → Friction stir weld-defect forming mechanisms of thick butt-joints. → Relationship between weld-defects and friction stir welding process parameters. → Multiple non-destructive testing methods applied to friction stir welds. → Empirical criterion basing on mass-conservation for inner material-loss defects. → Nonlinear correlation between weld strengths and root-flaw lengths. -- Abstract: The present study focused on the relationship between primary friction stir welding process parameters and varied types of weld-defect discovered in aluminum 2219-T6 friction stir butt-welds of thick plates, meanwhile, the weld-defect forming mechanisms were investigated. Besides a series of optical metallographic examinations for friction stir butt welds, multiple non-destructive testing methods including X-ray detection, ultrasonic C-scan testing, ultrasonic phased array inspection and fluorescent penetrating fluid inspection were successfully used aiming to examine the shapes and existence locations of different weld-defects. In addition, precipitated Al 2 Cu phase coarsening particles were found around a 'kissing-bond' defect within the weld stirred nugget zone by means of scanning electron microscope and energy dispersive X-ray analysis. On the basis of volume conservation law in material plastic deformation, a simple empirical criterion for estimating the existence of inner material-loss defects was proposed. Defect-free butt joints were obtained after process optimization of friction stir welding for aluminum 2219-T6 plates in 17-20 mm thickness. Process experiments proved that besides of tool rotation speed and travel speed, more other appropriate process parameter variables played important roles at the formation of high-quality friction stir welds, such as tool-shoulder target depth, spindle tilt angle, and fixture clamping conditions on the work-pieces. Furthermore, the nonlinear correlation between weld tensile strengths and weld crack

  9. Testing for multiple invasion routes and source populations for the invasive brown treesnake (Boiga irregularis) on Guam: implications for pest management

    Science.gov (United States)

    Richmond, Jonathan Q.; Wood, Dustin A.; Stanford, James W.; Fisher, Robert N.

    2014-01-01

    The brown treesnake (Boiga irregularis) population on the Pacific island of Guam has reached iconic status as one of the most destructive invasive species of modern times, yet no published works have used genetic data to identify a source population. We used DNA sequence data from multiple genetic markers and coalescent-based phylogenetic methods to place the Guam population within the broader phylogeographic context of B. irregularis across its native range and tested whether patterns of genetic variation on the island are consistent with one or multiple introductions from different source populations. We also modeled a series of demographic scenarios that differed in the effective size and duration of a population bottleneck immediately following the invasion on Guam, and measured the fit of these simulations to the observed data using approximate Bayesian computation. Our results exclude the possibility of serial introductions from different source populations, and instead verify a single origin from the Admiralty Archipelago off the north coast of Papua New Guinea. This finding is consistent with the hypothesis thatB. irregularis was accidentally transported to Guam during military relocation efforts at the end of World War II. Demographic model comparisons suggest that multiple snakes were transported to Guam from the source locality, but that fewer than 10 individuals could be responsible for establishing the population. Our results also provide evidence that low genetic diversity stemming from the founder event has not been a hindrance to the ecological success of B. irregularis on Guam, and at the same time offers a unique ‘genetic opening’ to manage snake density using classical biological approaches.

  10. Characterizing the Joint Effect of Diverse Test-Statistic Correlation Structures and Effect Size on False Discovery Rates in a Multiple-Comparison Study of Many Outcome Measures

    Science.gov (United States)

    Feiveson, Alan H.; Ploutz-Snyder, Robert; Fiedler, James

    2011-01-01

    In their 2009 Annals of Statistics paper, Gavrilov, Benjamini, and Sarkar report the results of a simulation assessing the robustness of their adaptive step-down procedure (GBS) for controlling the false discovery rate (FDR) when normally distributed test statistics are serially correlated. In this study we extend the investigation to the case of multiple comparisons involving correlated non-central t-statistics, in particular when several treatments or time periods are being compared to a control in a repeated-measures design with many dependent outcome measures. In addition, we consider several dependence structures other than serial correlation and illustrate how the FDR depends on the interaction between effect size and the type of correlation structure as indexed by Foerstner s distance metric from an identity. The relationship between the correlation matrix R of the original dependent variables and R, the correlation matrix of associated t-statistics is also studied. In general R depends not only on R, but also on sample size and the signed effect sizes for the multiple comparisons.

  11. Investigation of Dysphagia After Antireflux Surgery by High-resolution Manometry: Impact of Multiple Water Swallows and a Solid Test Meal on Diagnosis, Management, and Clinical Outcome.

    Science.gov (United States)

    Wang, Yu Tien; Tai, Ling Fung; Yazaki, Etsuro; Jafari, Jafar; Sweis, Rami; Tucker, Emily; Knowles, Kevin; Wright, Jeff; Ahmad, Saqib; Kasi, Madhavi; Hamlett, Katharine; Fox, Mark R; Sifrim, Daniel

    2015-09-01

    Management of patients with dysphagia, regurgitation, and related symptoms after antireflux surgery is challenging. This prospective, case-control study tested the hypothesis that compared with standard high-resolution manometry (HRM) with single water swallows (SWS), adding multiple water swallows (MWS) and a solid test meal increases diagnostic yield and clinical impact of physiological investigations. Fifty-seven symptomatic and 12 asymptomatic patients underwent HRM with SWS, MWS, and a solid test meal. Dysphagia and reflux were assessed by validated questionnaires. Diagnostic yield of standard and full HRM studies with 24-hour pH-impedance monitoring was compared. Pneumatic dilatation was performed for outlet obstruction on HRM studies. Clinical outcome was assessed by questionnaires and an analogue scale with "satisfactory" defined as at least 40% symptom improvement requiring no further treatment. Postoperative esophagogastric junction pressure was similar in all groups. Abnormal esophagogastric junction morphology (double high pressure band) was more common in symptomatic than in control patients (13 of 57 vs 0 of 12, P = .004). Diagnostic yield of HRM was 11 (19%), 11 (19%), and 33 of 57 (58%), with SWS, MWS, and solids, respectively (P dysphagia (19 of 27, 70%). Outlet obstruction was present in 4 (7%), 11 (19%), and 15 of 57 patients (26%) with SWS, MWS, and solids, respectively (P < .009). No asymptomatic control had clinically relevant dysfunction on solid swallows. Dilatation was performed in 12 of 15 patients with outlet obstruction during the test meal. Symptom response was satisfactory, good, or excellent in 7 of 12 (58%) with no serious complications. The addition of MWS and a solid test meal increases the diagnostic yield of HRM studies in patients with symptoms after fundoplication and identifies additional patients with outlet obstruction who benefit from endoscopic dilatation. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All

  12. The Multiple Object Test as a Performance Based Tool to Assess Cognitive Driven Activity of Daily Living Function in Parkinson's Disease.

    Science.gov (United States)

    Glonnegger, Hannah; Beyle, Aline; Cerff, Bernhard; Gräber, Susanne; Csoti, Ilona; Berg, Daniela; Liepelt-Scarfone, Inga

    2016-07-06

    There is need for multidimensional quantitative assessment of cognitive driven activities of daily living (ADL) functions in Parkinson's disease (PD). To determine whether there is an ADL profile related to cognitive impairment in PD assessed by the Multiple Object Test (MOT). We assumed MOT performance to be lower in PD patients versus controls and in PD patients with more severe cognitive impairment. 50 PD patients with no cognitive impairment (PD-NC), 54 patients with PD-mild cognitive impairment (PD-MCI), 29 with Parkinson's disease dementia (PDD), and 40 healthy controls (HC) were investigated. Besides comprehensive cognitive testing, the MOT, a performance based test consisting of five routine tasks (e.g., preparing a cup of coffee), was applied. Quantitative (total errors and time) and qualitative (error type) MOT parameters were analyzed. Total time and number of MOT errors was increased in PD patients compared to controls (p < 0.001). These parameters also differentiated PDD patients from other cognitive groups (p < 0.05). No control subject had ≥ 4 errors in the MOT, but 30% of PD patients, especially PDD, scored above this cut-off. Omission (p < 0.001) and mislocation (p < 0.03) errors were more prominent in PDD than other cognitive groups. Perplexity errors did not differ between PD-MCI and PDD but between PD-NC and PDD (p = 0.01). MOT parameters discriminating between cognitive groups correlated mainly with lower test performance in psychomotor speed and executive function. Performance based testing is promising to identify quantitative and qualitative ADL aspects differentiating between different cognitive groups which might be helpful for an early detection of PDD.

  13. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  14. Logistic regression analysis of multiple noninvasive tests for the prediction of the presence and extent of coronary artery disease in men

    International Nuclear Information System (INIS)

    Hung, J.; Chaitman, B.R.; Lam, J.; Lesperance, J.; Dupras, G.; Fines, P.; Cherkaoui, O.; Robert, P.; Bourassa, M.G.

    1985-01-01

    The incremental diagnostic yield of clinical data, exercise ECG, stress thallium scintigraphy, and cardiac fluoroscopy to predict coronary and multivessel disease was assessed in 171 symptomatic men by means of multiple logistic regression analyses. When clinical variables alone were analyzed, chest pain type and age were predictive of coronary disease, whereas chest pain type, age, a family history of premature coronary disease before age 55 years, and abnormal ST-T wave changes on the rest ECG were predictive of multivessel disease. The percentage of patients correctly classified by cardiac fluoroscopy (presence or absence of coronary artery calcification), exercise ECG, and thallium scintigraphy was 9%, 25%, and 50%, respectively, greater than for clinical variables, when the presence or absence of coronary disease was the outcome, and 13%, 25%, and 29%, respectively, when multivessel disease was studied; 5% of patients were misclassified. When the 37 clinical and noninvasive test variables were analyzed jointly, the most significant variable predictive of coronary disease was an abnormal thallium scan and for multivessel disease, the amount of exercise performed. The data from this study provide a quantitative model and confirm previous reports that optimal diagnostic efficacy is obtained when noninvasive tests are ordered sequentially. In symptomatic men, cardiac fluoroscopy is a relatively ineffective test when compared to exercise ECG and thallium scintigraphy

  15. Combining multiple hypothesis testing and affinity propagation clustering leads to accurate, robust and sample size independent classification on gene expression data

    Directory of Open Access Journals (Sweden)

    Sakellariou Argiris

    2012-10-01

    Full Text Available Abstract Background A feature selection method in microarray gene expression data should be independent of platform, disease and dataset size. Our hypothesis is that among the statistically significant ranked genes in a gene list, there should be clusters of genes that share similar biological functions related to the investigated disease. Thus, instead of keeping N top ranked genes, it would be more appropriate to define and keep a number of gene cluster exemplars. Results We propose a hybrid FS method (mAP-KL, which combines multiple hypothesis testing and affinity propagation (AP-clustering algorithm along with the Krzanowski & Lai cluster quality index, to select a small yet informative subset of genes. We applied mAP-KL on real microarray data, as well as on simulated data, and compared its performance against 13 other feature selection approaches. Across a variety of diseases and number of samples, mAP-KL presents competitive classification results, particularly in neuromuscular diseases, where its overall AUC score was 0.91. Furthermore, mAP-KL generates concise yet biologically relevant and informative N-gene expression signatures, which can serve as a valuable tool for diagnostic and prognostic purposes, as well as a source of potential disease biomarkers in a broad range of diseases. Conclusions mAP-KL is a data-driven and classifier-independent hybrid feature selection method, which applies to any disease classification problem based on microarray data, regardless of the available samples. Combining multiple hypothesis testing and AP leads to subsets of genes, which classify unknown samples from both, small and large patient cohorts with high accuracy.

  16. MCPerm: a Monte Carlo permutation method for accurately correcting the multiple testing in a meta-analysis of genetic association studies.

    Directory of Open Access Journals (Sweden)

    Yongshuai Jiang

    Full Text Available Traditional permutation (TradPerm tests are usually considered the gold standard for multiple testing corrections. However, they can be difficult to complete for the meta-analyses of genetic association studies based on multiple single nucleotide polymorphism loci as they depend on individual-level genotype and phenotype data to perform random shuffles, which are not easy to obtain. Most meta-analyses have therefore been performed using summary statistics from previously published studies. To carry out a permutation using only genotype counts without changing the size of the TradPerm P-value, we developed a Monte Carlo permutation (MCPerm method. First, for each study included in the meta-analysis, we used a two-step hypergeometric distribution to generate a random number of genotypes in cases and controls. We then carried out a meta-analysis using these random genotype data. Finally, we obtained the corrected permutation P-value of the meta-analysis by repeating the entire process N times. We used five real datasets and five simulation datasets to evaluate the MCPerm method and our results showed the following: (1 MCPerm requires only the summary statistics of the genotype, without the need for individual-level data; (2 Genotype counts generated by our two-step hypergeometric distributions had the same distributions as genotype counts generated by shuffling; (3 MCPerm had almost exactly the same permutation P-values as TradPerm (r = 0.999; P<2.2e-16; (4 The calculation speed of MCPerm is much faster than that of TradPerm. In summary, MCPerm appears to be a viable alternative to TradPerm, and we have developed it as a freely available R package at CRAN: http://cran.r-project.org/web/packages/MCPerm/index.html.

  17. Analysis of a multiple-well interference test in Miocene tuffaceous rocks at the C-Hole complex, May--June 1995, Yucca Mountain, Nye County, Nevada

    International Nuclear Information System (INIS)

    Geldon, A.L.; Umari, A.M.A.; Earle, J.D.; Fahy, M.F.; Gemmell, J.M.; Darnell, J.

    1998-01-01

    A multiple-well interference (pumping) test was conducted in Miocene tuffaceous rocks at the C-hole complex at Yucca Mountain, Nev., from May 22 to June 12, 1995, by the US Geological Survey, in cooperation with the US Department of Energy. This pumping test was conducted as part of investigations to determine the suitability of Yucca Mountain as a potential site for the storage of high-level nuclear waste in a mined geologic repository. During the test, borehole UE-25 c number-sign 3 was pumped for 10 days at an average rate of 17.9 liters per second. Drawdown in 6 observation wells completed in Miocene tuffaceous rocks 29.0--3,525.6 meters from the pumping well ranged from 0 to 0.42 meters 14,000 minutes after pumping started. The spatial distribution of this drawdown indicates that a northwest-trending zone of discontinuous faults might be affecting ground-water movement in the Miocene tuffaceous rocks near the C-holes. No drawdown was observed in a borehole completed in a regional Paleozoic carbonate aquifer 630.0 meters from the pumping well. Consequently, it could not be determined during the pumping test if the Miocene tuffaceous rocks are connected hydraulically to the regional aquifer. Analyses of drawdown and recovery indicate that the Miocene tuffaceous rocks in the vicinity of the C-holes have transmissivity values of 1,600--3,200 meters squared per day, horizontal hydraulic conductivity values of 6.5--13 meters per day, vertical hydraulic conductivity values of 0.2--1.7 meters per day, storativity values of 0.001--0.003, and specific yield values of 0.01--0.2

  18. Genotyping and antifungal susceptibility testing of multiple Malassezia pachydermatis isolates from otitis and dermatitis cases in pets: is it really worth the effort?

    Science.gov (United States)

    Álvarez-Pérez, Sergio; García, Marta E; Peláez, Teresa; Blanco, José L

    2016-01-01

    A total of 216 colonies of Malassezia pachydermatis from 28 cases of fungal otitis or dermatitis in pets were genotyped by M13 fingerprinting and tested for antifungal susceptibility. A huge genetic diversity was found (157 M13 types in total), with all animals having a polyclonal pattern of infection (5.4 ± 1.5 genotypes/sample). Furthermore, analysis of molecular variance (AMOVA) revealed that most genetic diversity (44%) was found at the within sample level. In contrast, variability in antifungal susceptibility among isolates from the same sample was less important, with different M13 types displaying in most cases identical or very similar MIC results. Most isolates displayed high in vitro susceptibility to amphotericin B, terbinafine and all azoles tested except fluconazole, for which MIC values were always ≥4 μg/ml and a 26.9% of isolates displayed values ≥32 μg/ml. We conclude that although characterization of multiple yeast isolates results in a considerable increase in laboratory workload and expenses, it may help to get a better understanding of the epidemiology of M. pachydermatis in a given patient population. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. An association study of 13 SNPs from seven candidate genes with pediatric asthma and a preliminary study for genetic testing by multiple variants in Taiwanese population.

    Science.gov (United States)

    Wang, Jiu-Yao; Liou, Ya-Huei; Wu, Ying-Jye; Hsiao, Ya-Hsin; Wu, Lawrence Shih-Hsin

    2009-03-01

    Asthma is one of the most common chronic diseases in children. It is caused by complex interactions between various genetic factors and exposures to environmental allergens and irritants. Because of the heterogeneity of the disease and the genetic and cultural differences among different populations, a proper association study and genetic testing for asthma and susceptibility genes is difficult to perform. We assessed 13 single-nucleotide polymorphisms (SNPs) in seven well-known asthma susceptibility genes and looked for association with pediatric asthma using 449 asthmatic subjects and 512 non-asthma subjects in Taiwanese population. CD14-159 C/T and MS4A2 Glu237Gly were identified to have difference in genotype/allele frequencies between the control group and asthma patients. Moreover, the genotype synergistic analysis showed that the co-contribution of two functional SNPs was riskier or more protective from asthma attack. Our study provided a genotype synergistic method for studying gene-gene interaction on polymorphism basis and genetic testing using multiple polymorphisms.

  20. Development and Pilot Testing of 24-Hour Multiple-Pass Recall to Assess Dietary Intake of Toddlers of Somali- and Iraqi-Born Mothers Living in Norway

    Directory of Open Access Journals (Sweden)

    Navnit Kaur Grewal

    2014-06-01

    Full Text Available The aim of this study was to develop, test, and evaluate a 24-h recall procedure to assess the dietary intake of toddlers of Somali- and Iraqi-born mothers living in Norway. A protocol for a 24-h multiple-pass recall procedure, registration forms, and visual tools (a picture library for food identification and portion size estimation was developed and tested in 12 mothers from Somalia and Iraq with children aged 10–21 months. Five female field workers were recruited and trained to conduct the interviews. Evaluation data for the 24-h recall procedure were collected from both the mothers and the field workers. Nutrient intake was calculated using a Norwegian dietary calculation system. Each child’s estimated energy intake was compared with its estimated energy requirement. Both the mothers and the field workers found the method feasible and the visual tools useful. The estimated energy intake corresponded well with the estimated energy requirement for most of the children (within mean ± 2 SD, except for three. The pilot study identified the need for additional foods in the picture library and some crucial aspects in training and supervising the field workers to reduce sources of error in the data collection.

  1. Testing the Hypothesis of Multiple Origins of Holoparasitism in Orobanchaceae: Phylogenetic Evidence from the Last Two Unplaced Holoparasitic Genera, Gleadovia and Phacellanthus

    Directory of Open Access Journals (Sweden)

    Weirui Fu

    2017-08-01

    Full Text Available Orobanchaceae is the largest family among the parasitic angiosperms. It comprises non-parasites, hemi- and holoparasites, making this family an ideal test case for studying the evolution of parasitism. Previous phylogenetic analyses showed that holoparasitism had arisen at least three times from the hemiparasitic taxa in Orobanchaceae. Until now, however, not all known genera of Orobanchaceae were investigated in detail. Among them, the unknown phylogenetic positions of the holoparasites Gleadovia and Phacellanthus are the key to testing how many times holoparasitism evolved. Here, we provide clear evidence for the first time that they are members of the tribe Orobancheae, using sequence data from multiple loci (nuclear genes ITS, PHYA, PHYB, and plastid genes rps2, matK. Gleadovia is an independent lineage whereas Phacellanthus should be merged into genus Orobanche section Orobanche. Our results unambiguously support the hypothesis that there are only three origins of holoparasitism in Orobanchaceae. Divergence dating reveals for the first time that the three origins of holoparasitism were not synchronous. Our findings suggest that holoparasitism can persist in specific clades for a long time and holoparasitism may evolve independently as an adaptation to certain hosts.

  2. Clinical practice of analysis of anti-drug antibodies against interferon beta and natalizumab in multiple sclerosis patients in Europe: A descriptive study of test results.

    Directory of Open Access Journals (Sweden)

    Jenny Link

    Full Text Available Antibodies against biopharmaceuticals (anti-drug antibodies, ADA have been a well-integrated part of the clinical care of multiple sclerosis (MS in several European countries. ADA data generated in Europe during the more than 10 years of ADA monitoring in MS patients treated with interferon beta (IFNβ and natalizumab have been pooled and characterized through collaboration within a European consortium. The aim of this study was to report on the clinical practice of ADA testing in Europe, considering the number of ADA tests performed and type of ADA assays used, and to determine the frequency of ADA testing against the different drug preparations in different countries. A common database platform (tranSMART for querying, analyzing and storing retrospective data of MS cohorts was set up to harmonize the data and compare results of ADA tests between different countries. Retrospective data from six countries (Sweden, Austria, Spain, Switzerland, Germany and Denmark on 20,695 patients and on 42,555 samples were loaded into tranSMART including data points of age, gender, treatment, samples, and ADA results. The previously observed immunogenic difference among the four IFNβ preparations was confirmed in this large dataset. Decreased usage of the more immunogenic preparations IFNβ-1a subcutaneous (s.c. and IFNβ-1b s.c. in favor of the least immunogenic preparation IFNβ-1a intramuscular (i.m. was observed. The median time from treatment start to first ADA test correlated with time to first positive test. Shorter times were observed for IFNβ-1b-Extavia s.c. (0.99 and 0.94 years and natalizumab (0.25 and 0.23 years, which were introduced on the market when ADA testing was already available, as compared to IFNβ-1a i.m. (1.41 and 2.27 years, IFNβ-1b-Betaferon s.c. (2.51 and 1.96 years and IFNβ-1a s.c. (2.11 and 2.09 years which were available years before routine testing began. A higher rate of anti-IFNβ ADA was observed in test samples taken from

  3. Dose-response testing with nickel sulphate using the TRUE test in nickel-sensitive individuals. Multiple nickel sulphate patch-test reactions do not cause an 'angry back'

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Lidén, C; Hansen, J

    1993-01-01

    The aim of this study was to employ the TRUE test assay to confirm the presence or absence of the 'angry back' phenomenon, i.e. that a strong positive patch-test reaction heightens adjacent patch-test response. In addition, we wished to establish the dose-response relationship for nickel sulphate...... back' phenomenon was not apparent in this study, as the spill-over effect was not statistically significant. Strong reactions to high concentrations of nickel sulphate did not enhance the response to adjacent lower concentrations of nickel sulphate....

  4. Comparison of Sleep Latency and Number of SOREMPs in the Home and Hospital With a Modified Multiple Sleep Latency Test: A Randomized Crossover Study.

    Science.gov (United States)

    Beiske, Kornelia K; Sand, Trond; Rugland, Eyvind; Stavem, Knut

    2017-05-01

    Comparison of mean sleep latencies and number of sleep-onset rapid eye movement periods (SOREMPs) between modified multiple sleep latency test (MSLT) performed in the unattended home and in-hospital laboratory setting. A randomized crossover single-blinded design. Thirty-four subjects referred to MSLT for suspected hypersomnia or narcolepsy were included. Participants were randomized to perform modified MSLT in the unattended home or in the hospital first. Scores in the two settings were compared using Wilcoxon signed-rank test or exact McNemar test. Agreement between home and hospital categorized mean sleep latency and number of SOREMPs was assessed using simple kappa (κ) and proportion agreement. Agreement between home and hospital mean sleep latency was assessed using a Bland-Altman plot and an intraclass correlation coefficient. There was no difference between home and hospital assessment of mean sleep latency (P = 0.86). Two or more SOREMPs were found more frequently on modified MSLTs performed at home compared with those at the hospital (7 and 2, respectively; P = 0.025). Agreement was moderate for categorized sleep latency (κ = 0.53) and fair for categorized SOREMPs (κ = 0.39) in the 2 settings. Analysis of mean sleep latency using intraclass correlation coefficient showed a very good agreement between the two settings. Group mean sleep latency for home modified MSLTs seems to be reliable compared with that for the attended sleep-laboratory setting. Higher rate of SOREMP in the unattended home suggests that napping in a familiar environment facilitates the transition into REM sleep. Further studies are needed to assess the normal limit, sensitivity, and specificity for SOREMP at home before the clinical utility of home-based napping can be determined.

  5. [A case report of early-onset Alzheimer's disease with multiple psychotic symptoms, finally diagnosed as APPV717I mutation by genetic testing].

    Science.gov (United States)

    Ishimaru, Takashi; Ochi, Shinichiro; Matsumoto, Teruhisa; Yoshida, Taku; Abe, Masao; Toyota, Yasutaka; Fukuhara, Ryuji; Tanimukai, Satoshi; Ueno, Shu-ichi

    2013-01-01

    It is difficult to confirm a diagnosis of early-onset Alzheimer's disease (EOAD) because patients sometimes have non-specific cortical features, such as psychiatric symptoms, executive functional impairment, and pyramidal symptoms, along with typical symptoms, such as recent memory impairment and disorientation. We encountered a patient with multiple psychotic symptoms, finally diagnosed with EOAD on genetic testing. A right-handed sixty-year-old man, whose mother was suspected of having dementia, developed memory impairment at the age of fifty, disorientation at the age of fifty-six, and both visual hallucination and dressing apraxia at the age of fifty-nine. After admission to a psychiatric hospital for treatment, his symptoms disappeared with antipsychotic medication. However, his ADL were declining and so he was referred to our university hospital. He had frontal lobe symptoms, pyramidal signs, and extrapyramidal signs with severe dementia. Neuropsychological examinations were not possible because of sedation. On brain MRI, he showed diffuse atrophy of the cerebral cortex and hippocampus. HMPO-SPECT showed hypoperfusion of cerebral cortices diffusely. We decided to perform genetic testing because he had both family and alcohol abuse histories. He showed EOAD with V717I mutation of the amyloid precursor protein gene. After the discontinuation of antipsychotics, excessive sedation and extrapyramidal signs disappeared. A dose of 10 mg of donepezil was effective to improve motivation and activity, and his mini mental examination score was calculable after recovery. The case supports usefulness of applying genetic testing for Alzheimer's disease to patients with early onset dementia, even when they do not have a family history.

  6. Multiple Perspectives / Multiple Readings

    Directory of Open Access Journals (Sweden)

    Simon Biggs

    2005-01-01

    Full Text Available People experience things from their own physical point of view. What they see is usually a function of where they are and what physical attitude they adopt relative to the subject. With augmented vision (periscopes, mirrors, remote cameras, etc we are able to see things from places where we are not present. With time-shifting technologies, such as the video recorder, we can also see things from the past; a time and a place we may never have visited.In recent artistic work I have been exploring the implications of digital technology, interactivity and internet connectivity that allow people to not so much space/time-shift their visual experience of things but rather see what happens when everybody is simultaneously able to see what everybody else can see. This is extrapolated through the remote networking of sites that are actual installation spaces; where the physical movements of viewers in the space generate multiple perspectives, linked to other similar sites at remote locations or to other viewers entering the shared data-space through a web based version of the work.This text explores the processes involved in such a practice and reflects on related questions regarding the non-singularity of being and the sense of self as linked to time and place.

  7. {sup 11}C-PBR28 imaging in multiple sclerosis patients and healthy controls: test-retest reproducibility and focal visualization of active white matter areas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eunkyung; Gallezot, Jean-Dominique; Planeta, Beata; Lin, Shu-Fei; Lim, Keunpoong; Chen, Ming-Kai; Huang, Yiyun; Carson, Richard E. [Yale School of Medicine, PET Center, Department of Diagnostic Radiology, 801 Howard Avenue, PO Box 208048, New Haven, CT (United States); Delgadillo, Aracely; Liu, Shuang; O' Connor, Kevin C.; Lee, Jae-Yun; Chastre, Anne; Pelletier, Daniel [Yale School of Medicine, Department of Neurology, New Haven, CT (United States); Seneca, Nicholas; Leppert, David [Hoffmann-La Roche Ltd, Pharmaceuticals Division, Basel (Switzerland)

    2015-04-02

    Activated microglia play a key role in inflammatory demyelinating injury in multiple sclerosis (MS). Microglial activation can be measured in vivo using a positron emission tomography (PET) ligand {sup 11}C-PBR28. We evaluated the test-retest variability (TRV) and lesion detectability of {sup 11}C-PBR28 binding in MS subjects and healthy controls (HCs) with high-resolution PET. Four clinically and radiologically stable relapsing-remitting MS subjects (age 41 ± 7 years, two men/two women) and four HCs (age 42 ± 8 years, 2 two men/two women), matched for translocator protein genotype [two high- and two medium-affinity binders according to DNA polymorphism (rs6971) in each group], were studied for TRV. Another MS subject (age 41 years, male) with clinical and radiological activity was studied for lesion detectability. Dynamic data were acquired over 120 min after injection of 634 ± 101 MBq {sup 11}C-PBR28. For the TRV study, subjects were scanned twice, on average 1.4 weeks apart. Volume of distribution (V{sub T}) derived from multilinear analysis (MA1) modeling (t* = 30 min, using arterial input data) was the main outcome measure. Mean test V{sub T} values (ml cm{sup -3}) were 3.9 ± 1.4 in the whole brain gray matter (GM), 3.6 ± 1.2 in the whole brain white matter (WM) or normal-appearing white matter (NAWM), and 3.3 ± 0.6 in MS WM lesions; mean retest V{sub T} values were 3.7 ± 1.0 in GM, 3.3 ± 0.9 in WM/NAWM, and 3.3 ± 0.7 in MS lesions. Test-retest results showed a mean absolute TRV ranging from 7 to 9 % across GM, WM/NAWM, and MS lesions. High-affinity binders demonstrated 30 % higher V{sub T} than medium-affinity binders in GM. Focal {sup 11}C-PBR28 uptake was detected in two enhancing lesions of the active MS patient. High-resolution {sup 11}C-PBR28 PET can visualize focal areas where microglial activation is known to be present and has good test-retest reproducibility in the human brain. {sup 11}C-PBR28 PET is likely to be valuable for monitoring both

  8. Effect modification of air pollution on Urinary 8-Hydroxy-2'-Deoxyguanosine by genotypes: an application of the multiple testing procedure to identify significant SNP interactions

    Directory of Open Access Journals (Sweden)

    Christiani David C

    2010-12-01

    Full Text Available Abstract Background Air pollution is associated with adverse human health, but mechanisms through which pollution exerts effects remain to be clarified. One suggested pathway is that pollution causes oxidative stress. If so, oxidative stress-related genotypes may modify the oxidative response defenses to pollution exposure. Methods We explored the potential pathway by examining whether an array of oxidative stress-related genes (twenty single nucleotide polymorphisms, SNPs in nine genes modified associations of pollutants (organic carbon (OC, ozone and sulfate with urinary 8-hydroxy-2-deoxygunosine (8-OHdG, a biomarker of oxidative stress among the 320 aging men. We used a Multiple Testing Procedure in R modified by our team to identify the significance of the candidate genes adjusting for a priori covariates. Results We found that glutathione S-tranferase P1 (GSTP1, rs1799811, M1 and catalase (rs2284367 and group-specific component (GC, rs2282679, rs1155563 significantly or marginally significantly modified effects of OC and/or sulfate with larger effects among those carrying the wild type of GSTP1, catalase, non-wild type of GC and the non-null of GSTM1. Conclusions Polymorphisms of oxidative stress-related genes modified effects of OC and/or sulfate on 8-OHdG, suggesting that effects of OC or sulfate on 8-OHdG and other endpoints may be through the oxidative stress pathway.

  9. Pain Modulation after Oromucosal Cannabinoid Spray (SATIVEX® in Patients with Multiple Sclerosis: A Study with Quantitative Sensory Testing and Laser-Evoked Potentials

    Directory of Open Access Journals (Sweden)

    Mara Turri

    2018-06-01

    Full Text Available Background. Delta-9-tetrahydrocannabinol (THC/cannabidiol (CBD (nabiximols or Sativex® is an oromucosal spray formulation containing THC and CBD at an approximately 1:1 fixed ratio. Its administration for the treatment of pain in patients with multiple sclerosis (MS has been established. MS patients generally complain of different kinds of pain, including spasticity-related and neuropathic pain. In this study, we compared and evaluated pain modulation and thermal/pain threshold of MS patients before and after THC/CBD administration. Methods. 19 MS patients underwent clinical examination, numerical rating scale (NRS, quantitative sensory testing (QST, and laser-evoked potentials (LEPs before and after 1 month of therapy. Psychophysiological and neurophysiological data were compared to sex- and age-matched controls. Results. Patients reported a significant reduction in pain. We found statistically significant differences in LEP parameters between patients and controls but no significant change in LEP measures after THC/CBD therapy. Cold and heat detection thresholds were altered in patients but did not change after THC/CBD therapy. There was a significant increase in cold pain threshold by hand stimulation and a significant reduction in abnormal cold perception thresholds. Conclusions. Our results indicate that Sativex® therapy provides pain relief in MS patients and suggest that it might modulate peripheral cold-sensitive TRP channels.

  10. The relationship between office type and job satisfaction: Testing a multiple mediation model through ease of interaction and well-being.

    Science.gov (United States)

    Otterbring, Tobias; Pareigis, Jörg; Wästlund, Erik; Makrygiannis, Alexander; Lindström, Anton

    2018-05-01

    Objectives This cross-sectional study investigated the associations between office type (cellular, shared-room, small open-plan, and medium-sized open-plan) and employees' ease of interaction with coworkers, subjective well-being, and job satisfaction. Methods A brief survey including measures of office type, ease of interaction with coworkers, subjective well-being, and job satisfaction was sent electronically to 1500 Swedish real-estate agents, 271 of whom returned usable surveys. The data were analyzed using a regression-based serial multiple mediation model (PROCESS Model 6), which tested whether the relationship between office type and job satisfaction would be mediated by ease of interaction and, in turn, subjective well-being. Results A negative relationship was found between the number of coworkers sharing an office and employees' job satisfaction. This association was serially mediated by ease of interaction with coworkers and subjective well-being, with employees working in small and medium-sized open-plan offices reporting lower levels of both these aspects than employees who work in either cellular or shared-room offices. Conclusions Open-plan offices may have short-term financial benefits, but these benefits may be lower than the costs associated with decreased job satisfaction and well-being. Therefore, decision-makers should consider the impact of office type on employees rather than focusing solely on cost-effective office layout, flexibility, and productivity.

  11. Regression-Based Norms for the Symbol Digit Modalities Test in the Dutch Population: Improving Detection of Cognitive Impairment in Multiple Sclerosis?

    Science.gov (United States)

    Burggraaff, Jessica; Knol, Dirk L; Uitdehaag, Bernard M J

    2017-01-01

    Appropriate and timely screening instruments that sensitively capture the cognitive functioning of multiple sclerosis (MS) patients are the need of the hour. We evaluated newly derived regression-based norms for the Symbol Digit Modalities Test (SDMT) in a Dutch-speaking sample, as an indicator of the cognitive state of MS patients. Regression-based norms for the SDMT were created from a healthy control sample (n = 96) and used to convert MS patients' (n = 157) raw scores to demographically adjusted Z-scores, correcting for the effects of age, age2, gender, and education. Conventional and regression-based norms were compared on their impairment-classification rates and related to other neuropsychological measures. The regression analyses revealed that age was the only significantly influencing demographic in our healthy sample. Regression-based norms for the SDMT more readily detected impairment in MS patients than conventional normalization methods (32 patients instead of 15). Patients changing from an SDMT-preserved to -impaired status (n = 17) were also impaired on other cognitive domains (p < 0.05), except for visuospatial memory (p = 0.34). Regression-based norms for the SDMT more readily detect abnormal performance in MS patients than conventional norms, identifying those patients at highest risk for cognitive impairment, which was supported by a worse performance on other neuropsychological measures. © 2017 S. Karger AG, Basel.

  12. Characteristics of objective daytime sleep among individuals with earthquake-related posttraumatic stress disorder: A pilot community-based polysomnographic and multiple sleep latency test study.

    Science.gov (United States)

    Zhang, Yan; Li, Yun; Zhu, Hongru; Cui, Haofei; Qiu, Changjian; Tang, Xiangdong; Zhang, Wei

    2017-01-01

    Little is known about the objective sleep characteristics of patients with posttraumatic stress disorder (PTSD). The present study examines the association between PTSD symptom severity and objective daytime sleep characteristics measured using the Multiple Sleep Latency Test (MSLT) in therapy-naïve patients with earthquake-related PTSD. A total of 23 PTSD patients and 13 trauma-exposed non-PTSD (TEN-PTSD) subjects completed one-night in-lab polysomnography (PSG) followed by a standard MSLT. 8 of the 23 PTSD patients received paroxetine treatment. Compared to the TEN-PTSD subjects, no significant nighttime sleep disturbances were detected by PSG in the subjects with PTSD; however, a shorter mean MSLT value was found in the subjects with PTSD. After adjustment for age, sex, and body mass index, PTSD symptoms, particularly hyperarousal, were found to be independently associated with a shorter MSLT value. Further, the mean MSLT value increased significantly after therapy in PTSD subjects. A shorter MSLT value may be a reliable index of the medical severity of PTSD, while an improvement in MSLT values might also be a reliable marker for evaluating therapeutic efficacy in PTSD patients. Copyright © 2016. Published by Elsevier Ireland Ltd.

  13. The Cannabis Abuse Screening Test and the DSM-5 in the general population: Optimal thresholds and underlying common structure using multiple factor analysis.

    Science.gov (United States)

    Legleye, Stéphane

    2017-11-10

    The Cannabis Abuse Screening Test (CAST) aims at screening the problematic use of cannabis. It has never been validated against the Diagnostic and Statistical Manual of Mental Disorders (DSM)-5 and its relationships with this latter have never been studied. We used a probabilistic telephone survey collected in 2014 (1351 past-year cannabis users aged 15-64) implementing the CAST and a DSM-5 adaptation of the Munich Composite International Diagnostic Interview assessing cannabis use disorders. Data were weighted, and CAST items were considered categorical. Factorial structures were assessed with confirmatory factor analyses; the relationships between the instruments were studied with multiple factor analysis (MFA). One factor for the DSM-5 and two correlated factors for the CAST were the best confirmatory factor analyses solutions. The CAST thresholds for screening moderate/severe and severe cannabis use disorders were 5 (sensitivity = 78.2% and specificity = 79.6%) and 8 (sensitivity = 86.0% and specificity = 86.7%), respectively. The MFA identified two orthogonal dimensions: The first was equally shared by both instruments; the second was the second CAST dimension (extreme frequencies of use before midday and alone, memory problems, and reproaches from friends/family). The CAST structure and screening properties were confirmed. The MFA explains its screening performances by its first dimension and identified the problematic patterns (the second dimension) that are not captured by the DSM-5. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Prevalence of Walking-Related Motor Fatigue in Persons With Multiple Sclerosis: Decline in Walking Distance Induced by the 6-Minute Walk Test.

    Science.gov (United States)

    Leone, Carmela; Severijns, Deborah; Doležalová, Vendula; Baert, Ilse; Dalgas, Ulrik; Romberg, Anders; Bethoux, Francois; Gebara, Benoit; Santoyo Medina, Carmen; Maamâgi, Heigo; Rasova, Kamila; Maertens de Noordhout, Benoît; Knuts, Kathy; Skjerbaek, Anders; Jensen, Ellen; Wagner, Joanne M; Feys, Peter

    2016-05-01

    To investigate the individual occurrence of walking-related motor fatigue in persons with multiple sclerosis (PwMS), according to disability level and disease phenotype.Study design This was a cross-sectional, multinational study.Participants They were 208 PwMS from 11 centers with Expanded Disability Status Scale (EDSS) scores up to 6.5. The percentage change in distance walked (distance walked index, DWI) was calculated between minute 6 and 1 (DWI(6-1)) of the 6-Minute Walk Test (6MWT). Its magnitude was used to classify participants into 4 subgroups: (1) DWI(6-1)[≥5%], (2) DWI(6-1)[5%; -5%], (3) DWI(6-1)[-5%; > -15%], and (4) DWI(6-1)[≤-15%]. The latter group was labeled as having walking-related motor fatigue. PwMS were stratified into 5 subgroups based on the EDSS (0-2.5, 3-4, 4.5-5.5, 6, 6.5) and 3 subgroups based on MS phenotype (relapsing remitting [RR], primary progressive [PP], and secondary progressive [SP]). The DWI6-1was ≥5% in 16 PwMS (7.7%), between 5% and -5% in 70 PwMS (33.6%), between -5% and -15% in 58 PwMS (24%), and ≤-15% in 64 PwMS (30.8%). The prevalence of walking-related motor fatigue (DWI(6-1)[≤-15%]) was significantly higher among the progressive phenotype (PP = 50% and SP = 39%; RR = 15.6%) and PwMS with higher disability level (EDSS 4.5-5.5 = 48.3%, 6 = 46.3% and 6.5 = 51.5%, compared with EDSS 0-2.5 = 7.8% and 3-4 = 16.7%;P< .05). Stepwise multiple regression analysis indicated that EDSS, but not MS phenotype, explained a significant part of the variance in DWI(6-1)(R(2)= 0.086;P< .001). More than one-third of PwMS showed walking-related motor fatigue during the 6MWT, with its prevalence greatest in more disabled persons (up to 51%) and in those with progressive MS phenotype (up to 50%). Identification of walking-related motor fatigue may lead to better-tailored interventions. © The Author(s) 2015.

  15. Multiple sclerosis

    Science.gov (United States)

    ... indwelling catheter Osteoporosis or thinning of the bones Pressure sores Side effects of medicines used to treat the ... Daily bowel care program Multiple sclerosis - discharge Preventing pressure ulcers Swallowing problems Images Multiple sclerosis MRI of the ...

  16. Tests of Multiplicative Models in Psychology: A Case Study Using the Unified Theory of Implicit Attitudes, Stereotypes, Self-Esteem, and Self-Concept

    Science.gov (United States)

    Blanton, Hart; Jaccard, James

    2006-01-01

    Theories that posit multiplicative relationships between variables are common in psychology. A. G. Greenwald et al. recently presented a theory that explicated relationships between group identification, group attitudes, and self-esteem. Their theory posits a multiplicative relationship between concepts when predicting a criterion variable.…

  17. Multiple-Choice Exams and Guessing: Results from a One-Year Study of General Chemistry Tests Designed to Discourage Guessing

    Science.gov (United States)

    Campbell, Mark L.

    2015-01-01

    Multiple-choice exams, while widely used, are necessarily imprecise due to the contribution of the final student score due to guessing. This past year at the United States Naval Academy the construction and grading scheme for the department-wide general chemistry multiple-choice exams were revised with the goal of decreasing the contribution of…

  18. Specific IgE Antibodies in Young Children with Atopic Dermatitis--Correlation of Multiple Allergen Simultaneous Immunoblot Test and ImmunoCap System.

    Science.gov (United States)

    Konopka, Ewa; Ceregra, Aldona; Maciorkowska, Elzbieta; Surowska, Barbara; Trojanowska, Ilona; Roszko-Kirpsza, Izabela; Cukrowska, Bozena

    2016-01-01

    Sensitization to food allergens is a common condition in pediatric atopic dermatitis (AD). Recently, the multiple allergen simultaneous test (MAST) allowing for a comprehensive assessment of atopy has been developed, but the usefulness in young AD children is not known. The aim of this study was to determine IgE specificity in AD children using MAST and to compare the results for selected food allergens with the reference ImmunoCap system. The study enrolled 50 children up to 2 years old with a diagnosis of AD. IgE antibodies were measured with the MAST-immunoblots. Children with specific IgE levels ≥ 0.35 kU/L were identified as sensitized to allergens. Most often children were sensitized to food allergens (egg white and yolk, hazelnuts, potato, cow's milk proteins, wheat flour, codfish, and soybean), but a high percentage of them also had IgE antibodies against house dust mites (12%), grass (10%), and birch (10%). Eight percent of children were sensitized to domestic animals (cats and dogs). Almost perfect (kappa index 0.8 - 1.0) and substantial (kappa index 0.6 - 0.8) agreement between MAST and ImmunoCap was found for food allergens except codfish. Pearson's analysis of antibody classes showed a very strong correlation between two methods (r = 0.8 - 1.0) for egg white, hazelnuts, potato, cow's milk proteins, wheat flour, and soybean, and a strong correlation (r = 0.6 - 0.79) was observed for peanut, egg yolk, and codfish. The study showed the frequent occurrence of IgE antibodies against food and airborne and animal allergens in young AD children and confirmed the usefulness of MAST-immunoblots for screening of sensitization in pediatric patients.

  19. Reference gene selection for quantitative gene expression studies during biological invasions: A test on multiple genes and tissues in a model ascidian Ciona savignyi.

    Science.gov (United States)

    Huang, Xuena; Gao, Yangchun; Jiang, Bei; Zhou, Zunchun; Zhan, Aibin

    2016-01-15

    As invasive species have successfully colonized a wide range of dramatically different local environments, they offer a good opportunity to study interactions between species and rapidly changing environments. Gene expression represents one of the primary and crucial mechanisms for rapid adaptation to local environments. Here, we aim to select reference genes for quantitative gene expression analysis based on quantitative Real-Time PCR (qRT-PCR) for a model invasive ascidian, Ciona savignyi. We analyzed the stability of ten candidate reference genes in three tissues (siphon, pharynx and intestine) under two key environmental stresses (temperature and salinity) in the marine realm based on three programs (geNorm, NormFinder and delta Ct method). Our results demonstrated only minor difference for stability rankings among the three methods. The use of different single reference gene might influence the data interpretation, while multiple reference genes could minimize possible errors. Therefore, reference gene combinations were recommended for different tissues - the optimal reference gene combination for siphon was RPS15 and RPL17 under temperature stress, and RPL17, UBQ and TubA under salinity treatment; for pharynx, TubB, TubA and RPL17 were the most stable genes under temperature stress, while TubB, TubA and UBQ were the best under salinity stress; for intestine, UBQ, RPS15 and RPL17 were the most reliable reference genes under both treatments. Our results suggest that the necessity of selection and test of reference genes for different tissues under varying environmental stresses. The results obtained here are expected to reveal mechanisms of gene expression-mediated invasion success using C. savignyi as a model species. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Cone penetrometer testing and discrete-depth groundwater sampling techniques: A cost-effective method of site characterization in a multiple-aquifer setting

    International Nuclear Information System (INIS)

    Zemo, D.A.; Pierce, Y.G.; Gallinatti, J.D.

    1992-01-01

    Cone penetrometer testing (CPT), combined with discrete-depth groundwater sampling methods, can reduce significantly the time and expense required to characterize large sites that have multiple aquifers. Results from the screening site characterization can be used to design and install a cost-effective monitoring well network. At a site in northern California, it was necessary to characterize the stratigraphy and the distribution of volatile organic compounds (VOCs) to a depth of 80 feet within a 1/2 mile-by-1/4-mile residential and commercial area in a complex alluvial fan setting. To expedite site characterization, a five-week field screening program was implemented that consisted of a shallow groundwater survey, CPT soundings, and discrete-depth groundwater sampling. Based on continuous lithologic information provided by the CPT soundings, four coarse-grained water-yielding sedimentary packages were identified. Eighty-three discrete-depth groundwater samples were collected using shallow groundwater survey techniques, the BAT Enviroprobe, or the QED HydroPunch 1, depending on subsurface conditions. A 20-well monitoring network was designed and installed to monitor critical points within each sedimentary package. Understanding the vertical VOC distribution and concentrations produced substantial cost savings by minimizing the number of permanent monitoring wells and reducing the number of costly conductor casings to be installed. Significant long-term cost savings will result from reduced sampling costs. Where total VOC concentrations exceeded 20 φg/l in the screening samples, a good correlation was found between the discrete-depth screening data and data from monitoring wells. Using a screening program to characterize the site before installing monitoring wells resulted in an estimated 50-percent reduction in costs for site characterization, 65-percent reduction in time for site characterization, and 50-percent reduction in long-term monitoring costs

  1. Statistical analysis of water-quality data containing multiple detection limits II: S-language software for nonparametric distribution modeling and hypothesis testing

    Science.gov (United States)

    Lee, L.; Helsel, D.

    2007-01-01

    Analysis of low concentrations of trace contaminants in environmental media often results in left-censored data that are below some limit of analytical precision. Interpretation of values becomes complicated when there are multiple detection limits in the data-perhaps as a result of changing analytical precision over time. Parametric and semi-parametric methods, such as maximum likelihood estimation and robust regression on order statistics, can be employed to model distributions of multiply censored data and provide estimates of summary statistics. However, these methods are based on assumptions about the underlying distribution of data. Nonparametric methods provide an alternative that does not require such assumptions. A standard nonparametric method for estimating summary statistics of multiply-censored data is the Kaplan-Meier (K-M) method. This method has seen widespread usage in the medical sciences within a general framework termed "survival analysis" where it is employed with right-censored time-to-failure data. However, K-M methods are equally valid for the left-censored data common in the geosciences. Our S-language software provides an analytical framework based on K-M methods that is tailored to the needs of the earth and environmental sciences community. This includes routines for the generation of empirical cumulative distribution functions, prediction or exceedance probabilities, and related confidence limits computation. Additionally, our software contains K-M-based routines for nonparametric hypothesis testing among an unlimited number of grouping variables. A primary characteristic of K-M methods is that they do not perform extrapolation and interpolation. Thus, these routines cannot be used to model statistics beyond the observed data range or when linear interpolation is desired. For such applications, the aforementioned parametric and semi-parametric methods must be used.

  2. MULTIPLE OBJECTS

    Directory of Open Access Journals (Sweden)

    A. A. Bosov

    2015-04-01

    Full Text Available Purpose. The development of complicated techniques of production and management processes, information systems, computer science, applied objects of systems theory and others requires improvement of mathematical methods, new approaches for researches of application systems. And the variety and diversity of subject systems makes necessary the development of a model that generalizes the classical sets and their development – sets of sets. Multiple objects unlike sets are constructed by multiple structures and represented by the structure and content. The aim of the work is the analysis of multiple structures, generating multiple objects, the further development of operations on these objects in application systems. Methodology. To achieve the objectives of the researches, the structure of multiple objects represents as constructive trio, consisting of media, signatures and axiomatic. Multiple object is determined by the structure and content, as well as represented by hybrid superposition, composed of sets, multi-sets, ordered sets (lists and heterogeneous sets (sequences, corteges. Findings. In this paper we study the properties and characteristics of the components of hybrid multiple objects of complex systems, proposed assessments of their complexity, shown the rules of internal and external operations on objects of implementation. We introduce the relation of arbitrary order over multiple objects, we define the description of functions and display on objects of multiple structures. Originality.In this paper we consider the development of multiple structures, generating multiple objects.Practical value. The transition from the abstract to the subject of multiple structures requires the transformation of the system and multiple objects. Transformation involves three successive stages: specification (binding to the domain, interpretation (multiple sites and particularization (goals. The proposed describe systems approach based on hybrid sets

  3. Predicting the oral pharmacokinetic profiles of multiple-unit (pellet) dosage forms using a modeling and simulation approach coupled with biorelevant dissolution testing: case example diclofenac sodium.

    Science.gov (United States)

    Kambayashi, Atsushi; Blume, Henning; Dressman, Jennifer B

    2014-07-01

    The objective of this research was to characterize the dissolution profile of a poorly soluble drug, diclofenac, from a commercially available multiple-unit enteric coated dosage form, Diclo-Puren® capsules, and to develop a predictive model for its oral pharmacokinetic profile. The paddle method was used to obtain the dissolution profiles of this dosage form in biorelevant media, with the exposure to simulated gastric conditions being varied in order to simulate the gastric emptying behavior of pellets. A modified Noyes-Whitney theory was subsequently fitted to the dissolution data. A physiologically-based pharmacokinetic (PBPK) model for multiple-unit dosage forms was designed using STELLA® software and coupled with the biorelevant dissolution profiles in order to simulate the plasma concentration profiles of diclofenac from Diclo-Puren® capsule in both the fasted and fed state in humans. Gastric emptying kinetics relevant to multiple-units pellets were incorporated into the PBPK model by setting up a virtual patient population to account for physiological variations in emptying kinetics. Using in vitro biorelevant dissolution coupled with in silico PBPK modeling and simulation it was possible to predict the plasma profile of this multiple-unit formulation of diclofenac after oral administration in both the fasted and fed state. This approach might be useful to predict variability in the plasma profiles for other drugs housed in multiple-unit dosage forms. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Multiple sclerosis

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Kuehn, A.L.; Backens, M.; Papanagiotou, P.; Shariat, K.; Kostopoulos, P.

    2008-01-01

    Multiple sclerosis is the most common chronic inflammatory disease of myelin with interspersed lesions in the white matter of the central nervous system. Magnetic resonance imaging (MRI) plays a key role in the diagnosis and monitoring of white matter diseases. This article focuses on key findings in multiple sclerosis as detected by MRI. (orig.) [de

  5. Method for aquatic multiple species toxicant testing: acute toxicity of 10 chemicals to 5 vertebrates and 2 invertebrates. [Pimephales promelas; Carassius auratus; Ictalurus punctatus; Lepomis macrochirus; Salmo gairdneri; Orconectes immunis; Aplexa hypnorum

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.L.; Holcombe, G.W.

    1985-01-01

    A method was developed to simultaneously ascertain 96 h LC/sub 50/ values for seven freshwater species in a single flow through test with measured concentrations. It allows interspecific comparisons, easy determination of the most sensitive species, and cuts cost of labor, materials and chemical analysis for measured concentration tests. Species tested included fathead minnows Pimephales promelas, goldfish Carassius auratus, channel catfish Ictalurus punctatus, bluegill Lepomis macrochirus, rainbow trout Salmo gairdneri, crayfish Orconectes immunis and snails Aplexa hypnorum. Compounds tested were pentachlorophenol, 2-chloroethanol, 2,4-pentanedione, hexachloroethane, ..cap alpha..-bromo-2',5'-dimethoxyacetophenone, benzaldehyde, 1,3-dichloro-4,6-dinitro-benzene, dursban, sevin and cadmium chloride. The LC/sub 50/ values from these multiple species tests compared favourably with those determined using single species tests at this laboratory, usually within 20%.

  6. Feasibility, Test-Retest Reliability, and Interrater Reliability of the Modified Ashworth Scale and Modified Tardieu Scale in Persons with Profound Intellectual and Multiple Disabilities

    Science.gov (United States)

    Waninge, A.; Rook, R. A.; Dijkhuizen, A.; Gielen, E.; van der Schans, C. P.

    2011-01-01

    Caregivers of persons with profound intellectual and multiple disabilities (PIMD) often describe the quality of the daily movements of these persons in terms of flexibility or stiffness. Objective outcome measures for flexibility and stiffness are muscle tone or level of spasticity. Two instruments used to grade muscle tone and spasticity are the…

  7. Feasibility, test-retest reliability, and interrater reliability of the Modified Ashworth Scale and Modified Tardieu Scale in persons with profound intellectual and multiple disabilities

    NARCIS (Netherlands)

    Waninge, A.; Rook, R.A.; Dijkhuizen, A.; Gielen, E.; van der Schans, C.P.

    2011-01-01

    Caregivers of persons with profound intellectual and multiple disabilities (PIMD) often describe the quality of the daily movements of these persons in terms of flexibility or stiffness. Objective outcome measures for flexibility and stiffness are muscle tone or level of spasticity. Two instruments

  8. Design and in vitro performance testing of multiple air classifier technology in a new disposable inhaler concept (Twincer (R)) for high powder doses

    NARCIS (Netherlands)

    de Boer, Anne H; Hagedoorn, Paul; Westerman, Elsbeth M; Le Brun, Paul P H; Heijerman, Harry G M; Frijlink, Henderik W

    2006-01-01

    Dry powder inhalation of antibiotics in cystic fibrosis (CF) therapy may be a valuable alternative for wet nebulisation, because it saves time and it improves lung deposition. In this study, it is shown that the use of multiple air classifier technology enables effective dispersion of large amounts

  9. Multiple homicides.

    Science.gov (United States)

    Copeland, A R

    1989-09-01

    A study of multiple homicides or multiple deaths involving a solitary incident of violence by another individual was performed on the case files of the Office of the Medical Examiner of Metropolitan Dade County in Miami, Florida, during 1983-1987. A total of 107 multiple homicides were studied: 88 double, 17 triple, one quadruple, and one quintuple. The 236 victims were analyzed regarding age, race, sex, cause of death, toxicologic data, perpetrator, locale of the incident, and reason for the incident. This article compares this type of slaying with other types of homicide including those perpetrated by serial killers. Suggestions for future research in this field are offered.

  10. Multiple Sclerosis

    Science.gov (United States)

    Multiple sclerosis (MS) is a nervous system disease that affects your brain and spinal cord. It damages the myelin sheath, the material that surrounds and protects your nerve cells. This damage slows down ...

  11. Multiple myeloma.

    LENUS (Irish Health Repository)

    Collins, Conor D

    2012-02-01

    Advances in the imaging and treatment of multiple myeloma have occurred over the past decade. This article summarises the current status and highlights how an understanding of both is necessary for optimum management.

  12. Multiple mononeuropathy

    Science.gov (United States)

    ... with multiple mononeuropathy are prone to new nerve injuries at pressure points such as the knees and elbows. They should avoid putting pressure on these areas, for example, by not leaning on the elbows, crossing the knees, ...

  13. Evaluation of the expected moments algorithm and a multiple low-outlier test for flood frequency analysis at streamgaging stations in Arizona

    Science.gov (United States)

    Paretti, Nicholas V.; Kennedy, Jeffrey R.; Cohn, Timothy A.

    2014-01-01

    Flooding is among the costliest natural disasters in terms of loss of life and property in Arizona, which is why the accurate estimation of flood frequency and magnitude is crucial for proper structural design and accurate floodplain mapping. Current guidelines for flood frequency analysis in the United States are described in Bulletin 17B (B17B), yet since B17B’s publication in 1982 (Interagency Advisory Committee on Water Data, 1982), several improvements have been proposed as updates for future guidelines. Two proposed updates are the Expected Moments Algorithm (EMA) to accommodate historical and censored data, and a generalized multiple Grubbs-Beck (MGB) low-outlier test. The current guidelines use a standard Grubbs-Beck (GB) method to identify low outliers, changing the determination of the moment estimators because B17B uses a conditional probability adjustment to handle low outliers while EMA censors the low outliers. B17B and EMA estimates are identical if no historical information or censored or low outliers are present in the peak-flow data. EMA with MGB (EMA-MGB) test was compared to the standard B17B (B17B-GB) method for flood frequency analysis at 328 streamgaging stations in Arizona. The methods were compared using the relative percent difference (RPD) between annual exceedance probabilities (AEPs), goodness-of-fit assessments, random resampling procedures, and Monte Carlo simulations. The AEPs were calculated and compared using both station skew and weighted skew. Streamgaging stations were classified by U.S. Geological Survey (USGS) National Water Information System (NWIS) qualification codes, used to denote historical and censored peak-flow data, to better understand the effect that nonstandard flood information has on the flood frequency analysis for each method. Streamgaging stations were also grouped according to geographic flood regions and analyzed separately to better understand regional differences caused by physiography and climate. The B

  14. Human Factors Evaluation of the High Mobility Artillery Rocket System (HIMARS) in the Combined HIMARS-Guided Multiple Launch Rocket System (GMLRS) Initial Operational Test

    National Research Council Canada - National Science Library

    Hernandez, Charles L

    2007-01-01

    .... Using questionnaires specifically designed for this initial operational test (IOT), Soldier participant comments, we recorded impressions and recommendations for improving the HIMARS launcher and its associated support vehicles...

  15. [Multiple meningiomas].

    Science.gov (United States)

    Terrier, L-M; François, P

    2016-06-01

    Multiple meningiomas (MMs) or meningiomatosis are defined by the presence of at least 2 lesions that appear simultaneously or not, at different intracranial locations, without the association of neurofibromatosis. They present 1-9 % of meningiomas with a female predominance. The occurrence of multiple meningiomas is not clear. There are 2 main hypotheses for their development, one that supports the independent evolution of these tumors and the other, completely opposite, that suggests the propagation of tumor cells of a unique clone transformation, through cerebrospinal fluid. NF2 gene mutation is an important intrinsic risk factor in the etiology of multiple meningiomas and some exogenous risk factors have been suspected but only ionizing radiation exposure has been proven. These tumors can grow anywhere in the skull but they are more frequently observed in supratentorial locations. Their histologic types are similar to unique meningiomas of psammomatous, fibroblastic, meningothelial or transitional type and in most cases are benign tumors. The prognosis of these tumors is eventually good and does not differ from the unique tumors except for the cases of radiation-induced multiple meningiomas, in the context of NF2 or when diagnosed in children where the outcome is less favorable. Each meningioma lesion should be dealt with individually and their multiple character should not justify their resection at all costs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Development and Application of a Two-Tier Multiple-Choice Diagnostic Test for High School Students' Understanding of Cell Division and Reproduction

    Science.gov (United States)

    Sesli, Ertugrul; Kara, Yilmaz

    2012-01-01

    This study involved the development and application of a two-tier diagnostic test for measuring students' understanding of cell division and reproduction. The instrument development procedure had three general steps: defining the content boundaries of the test, collecting information on students' misconceptions, and instrument development.…

  17. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, Egon; Stenager, E N; Knudsen, Lone

    1994-01-01

    In a cross-sectional study of 117 randomly selected patients (52 men, 65 women) with definite multiple sclerosis, it was found that 76 percent were married or cohabitant, 8 percent divorced. Social contacts remained unchanged for 70 percent, but outgoing social contacts were reduced for 45 percent......, need for structural changes in home and need for pension became greater with increasing physical handicap. No significant differences between gender were found. It is concluded that patients and relatives are under increased social strain, when multiple sclerosis progresses to a moderate handicap...

  18. Social attribution test--multiple choice (SAT-MC) in schizophrenia: comparison with community sample and relationship to neurocognitive, social cognitive and symptom measures.

    Science.gov (United States)

    Bell, Morris D; Fiszdon, Joanna M; Greig, Tamasine C; Wexler, Bruce E

    2010-09-01

    This is the first report on the use of the Social Attribution Task - Multiple Choice (SAT-MC) to assess social cognitive impairments in schizophrenia. The SAT-MC was originally developed for autism research, and consists of a 64-second animation showing geometric figures enacting a social drama, with 19 multiple choice questions about the interactions. Responses from 85 community-dwelling participants and 66 participants with SCID confirmed schizophrenia or schizoaffective disorders (Scz) revealed highly significant group differences. When the two samples were combined, SAT-MC scores were significantly correlated with other social cognitive measures, including measures of affect recognition, theory of mind, self-report of egocentricity and the Social Cognition Index from the MATRICS battery. Using a cut-off score, 53% of Scz were significantly impaired on SAT-MC compared with 9% of the community sample. Most Scz participants with impairment on SAT-MC also had impairment on affect recognition. Significant correlations were also found with neurocognitive measures but with less dependence on verbal processes than other social cognitive measures. Logistic regression using SAT-MC scores correctly classified 75% of both samples. Results suggest that this measure may have promise, but alternative versions will be needed before it can be used in pre-post or longitudinal designs. (c) 2009 Elsevier B.V. All rights reserved.

  19. Multiple myeloma

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Ha, Choon Ho; Choi, Karp Shik

    1994-01-01

    Multiple myeloma is a malignant plasma cell tumor that is thought to originate proliferation of a single clone of abnormal plasma cell resulting production of a whole monoclonal paraprotein. The authors experienced a case of multiple myeloma with severe mandibular osteolytic lesions in 46-year-old female. As a result of careful analysis of clinical, radiological, histopathological features, and laboratory findings, we diagnosed it as multiple myeloma, and the following results were obtained. 1. Main clinical symptoms were intermittent dull pain on the mandibular body area, abnormal sensation of lip and pain due to the fracture on the right clavicle. 2. Laboratory findings revealed M-spike, reversed serum albumin-globulin ratio, markedly elevated ESR and hypercalcemia. 3. Radiographically, multiple osteolytic punched-out radiolucencies were evident on the skull, zygoma, jaw bones, ribs, clavicle and upper extremities. Enlarged liver and increased uptakes on the lesional sites in RN scan were also observed. 4. Histopathologically, markedly hypercellular marrow with sheets of plasmoblasts and megakaryocytes were also observed.

  20. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Jensen, K

    1988-01-01

    Forty-two (12%) of a total of 366 patients with multiple sclerosis (MS) had psychiatric admissions. Of these, 34 (81%) had their first psychiatric admission in conjunction with or after the onset of MS. Classification by psychiatric diagnosis showed that there was a significant positive correlation...

  1. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Knudsen, L; Jensen, K

    1991-01-01

    In a cross-sectional investigation of 116 patients with multiple sclerosis, the social and sparetime activities of the patient were assessed by both patient and his/her family. The assessments were correlated to physical disability which showed that particularly those who were moderately disabled...

  2. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Jensen, K

    1990-01-01

    An investigation on the correlation between ability to read TV subtitles and the duration of visual evoked potential (VEP) latency in 14 patients with definite multiple sclerosis (MS), indicated that VEP latency in patients unable to read the TV subtitles was significantly delayed in comparison...

  3. Multiple Sclerosis.

    Science.gov (United States)

    Plummer, Nancy; Michael, Nancy, Ed.

    This module on multiple sclerosis is intended for use in inservice or continuing education programs for persons who administer medications in long-term care facilities. Instructor information, including teaching suggestions, and a listing of recommended audiovisual materials and their sources appear first. The module goal and objectives are then…

  4. Parenting Multiples

    Science.gov (United States)

    ... when your babies do. Though it can be hard to let go of the thousand other things you need to do, remember that your well-being is key to your ability to take care of your babies. What Problems Can Happen? It may be hard to tell multiple babies apart when they first ...

  5. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  6. Family-Supportive Organization Perceptions, Multiple Dimensions of Work-Family Conflict, and Employee Satisfaction: A Test of Model across Five Samples

    Science.gov (United States)

    Lapierre, Laurent M.; Spector, Paul E.; Allen, Tammy D.; Poelmans, Steven; Cooper, Cary L.; O'Driscoll, Michael P.; Sanchez, Juan I.; Brough, Paula; Kinnunen, Ulla

    2008-01-01

    Using samples of managers drawn from five Western countries, we tested a theoretical model linking employees' perceptions of their work environment's family-supportiveness to six different dimensions of work-family conflict (WFC), and to their job satisfaction, family satisfaction, and life satisfaction. Our results are consistent with a causal…

  7. Critical evaluation and further development of methods for testing ecotoxicity at multiple pH using Daphnia magna and Pseudokirchneriella subcapitata

    DEFF Research Database (Denmark)

    Rendal, Cecilie; Trapp, Stefan; Kusk, Kresten Ole

    2012-01-01

    To meet the requirements of risk assessment legislature regarding the ecotoxicity of ionizing compounds, the present study attempts to establish easy, robust methods for testing ecotoxicity at various pH levels. An overview is given of the buffering methods found in the literature...

  8. Developing Sensitive and Selective Nanosensors: A Single Molecule - Multiple Excitation Source Approach. Altairnano Lithium Ion Nano-scaled Titanate Oxide Cell and Module Abuse Testing

    Science.gov (United States)

    2012-03-13

    Acids: Hydrochloric Acid, Nitric Acid, Sulfuric Acid, Acetic Acid. Bases: Ammonia , Household Bleach. Organics: Toluene, Acetone, Ethanol, Methanol...within a test cell equipped with a scrubber system and audio/video feeds. Twelve internal and four external thermocouples were connected to the data

  9. Multiple sclerosis

    International Nuclear Information System (INIS)

    Sadashima, Hiromichi; Kusaka, Hirofumi; Imai, Terukuni; Takahashi, Ryosuke; Matsumoto, Sadayuki; Yamamoto, Toru; Yamasaki, Masahiro; Maya, Kiyomi

    1986-01-01

    Eleven patients with a definite diagnosis of multiple sclerosis were examined in terms of correlations between the clinical features and the results of cranial computed tomography (CT), and magnetic resonance imaging (MRI). Results: In 5 of the 11 patients, both CT and MRI demonstrated lesions consistent with a finding of multiple sclerosis. In 3 patients, only MRI demonstrated lesions. In the remaining 3 patients, neither CT nor MRI revealed any lesion in the brain. All 5 patients who showed abnormal findings on both CT and MRI had clinical signs either of cerebral or brainstem - cerebellar lesions. On the other hand, two of the 3 patients with normal CT and MRI findings had optic-nerve and spinal-cord signs. Therefore, our results suggested relatively good correlations between the clinical features, CT, and MRI. MRI revealed cerebral lesions in two of the four patients with clinical signs of only optic-nerve and spinal-cord lesions. MRI demonstrated sclerotic lesions in 3 of the 6 patients whose plaques were not detected by CT. In conclusion, MRI proved to be more helpful in the demonstration of lesions attributable to chronic multiple sclerosis. (author)

  10. Towards more ecological relevance in sediment toxicity testing with fish: Evaluation of multiple bioassays with embryos of the benthic weatherfish (Misgurnus fossilis).

    Science.gov (United States)

    Schreiber, Benjamin; Fischer, Jonas; Schiwy, Sabrina; Hollert, Henner; Schulz, Ralf

    2018-04-01

    The effects of sediment contamination on fish are of high significance for the protection of ecosystems, human health and economy. However, standardized sediment bioassays with benthic fish species, that mimic bioavailability of potentially toxic compounds and comply with the requirements of alternative test methods, are still scarce. In order to address this issue, embryos of the benthic European weatherfish (Misgurnus fossilis) were exposed to freeze-dried sediment (via sediment contact assays (SCA)) and sediment extracts (via acute fish embryo toxicity tests) varying in contamination level. The extracts were gained by accelerated solvent extraction with (i) acetone and (ii) pressurized hot water (PHWE) and subsequently analyzed for polycyclic aromatic hydrocarbons, polychlorinated biphenyls and polychlorinated dibenzodioxins and dibenzofurans. Furthermore, embryos of the predominately used zebrafish (Danio rerio) were exposed to extracts from the two most contaminated sediments. Results indicated sufficient robustness of weatherfish embryos towards varying test conditions and sensitivity towards relevant sediment-bound compounds. Furthermore, a compliance of effect concentrations derived from weatherfish embryos exposed to sediment extracts (96h-LC 50 ) with both measured gradient of sediment contamination and previously published results was observed. In comparison to zebrafish, weatherfish embryos showed higher sensitivity to the bioavailability-mimicking extracts from PHWE but lower sensitivity to extracts gained with acetone. SCAs conducted with weatherfish embryos revealed practical difficulties that prevented an implementation with three of four sediments tested. In summary, an application of weatherfish embryos, using bioassays with sediment extracts from PHWE might increase the ecological relevance of sediment toxicity testing: it allows investigations using benthic and temperate fish species considering both bioavailable contaminants and animal welfare

  11. Removal efficiency of multiple poly- and perfluoroalkyl substances (PFASs) in drinking water using granular activated carbon (GAC) and anion exchange (AE) column tests.

    Science.gov (United States)

    McCleaf, Philip; Englund, Sophie; Östlund, Anna; Lindegren, Klara; Wiberg, Karin; Ahrens, Lutz

    2017-09-01

    Poly- and perfluoroalkyl substances (PFASs) have been detected in drinking water at relatively high concentrations throughout the world which has led to implementation of regulatory guidelines for specific PFASs in drinking water in several European countries and in the U.S. The Swedish National Food Agency has determined that the drinking water of over one third of the country's municipal consumers is at risk or already affected by PFAS contamination. The present study investigated the effects of perfluorocarbon chain length, functional group and isomer structure (branched or linear) on removal of multiple PFASs using granular activated carbon (GAC, Filtrasorb ® 400) and anion exchange (AE, Purolite ® A600) column experiments. The removal of 14 different PFASs, i.e. the C 3 C 11 , C 14 perfluoroalkyl carboxylic acids (PFCAs) (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, PFDoDA, PFTeDA), perfluorooctane sulfonamide (FOSA), and the C 4 , C 6 , C 8 perfluoroalkyl sulfonic acids (PFSAs) (PFBS, PFHxS, PFOS), was monitored for a 217 day period. The results indicate the selective nature of PFAS removal as the absorbents are loaded with PFASs and dissolved organic carbon (DOC). A clear relationship between perfluorocarbon chain length and removal efficiency of PFASs using GAC and AE was found while PFASs with sulfonate functional groups displayed greater removal efficiency than those with carboxylate groups. Similarly, time to column breakthrough increased with increasing perfluorocarbon chain length and was greater for the PFSAs than the PFCAs for both GAC and AE. Shorter carbon chained PFASs such as PFBA, PFPeA, PFHxA showed desorption behavior and long-chained PFASs showed increased removal towards the end of the experiment indicating agglomeration or micelle development. Linear isomers of PFOS, PFHxS, and perfluorooctane sulfonamide (FOSA) had greater column removal efficiencies using GAC (and also for AE at greater bed volume throughput) than the branched

  12. Emissions of toxic pollutants from compressed natural gas and low sulfur diesel-fueled heavy-duty transit buses tested over multiple driving cycles.

    Science.gov (United States)

    Kado, Norman Y; Okamoto, Robert A; Kuzmicky, Paul A; Kobayashi, Reiko; Ayala, Alberto; Gebel, Michael E; Rieger, Paul L; Maddox, Christine; Zafonte, Leo

    2005-10-01

    The number of heavy-duty vehicles using alternative fuels such as compressed natural gas (CNG) and new low-sulfur diesel fuel formulations and equipped with after-treatment devices are projected to increase. However, few peer-reviewed studies have characterized the emissions of particulate matter (PM) and other toxic compounds from these vehicles. In this study, chemical and biological analyses were used to characterize the identifiable toxic air pollutants emitted from both CNG and low-sulfur-diesel-fueled heavy-duty transit buses tested on a chassis dynamometer over three transient driving cycles and a steady-state cruise condition. The CNG bus had no after-treatment, and the diesel bus was tested first equipped with an oxidation catalyst (OC) and then with a catalyzed diesel particulate filter (DPF). Emissions were analyzed for PM, volatile organic compounds (VOCs; determined on-site), polycyclic aromatic hydrocarbons (PAHs), and mutagenic activity. The 2000 model year CNG-fueled vehicle had the highest emissions of 1,3-butadiene, benzene, and carbonyls (e.g., formaldehyde) of the three vehicle configurations tested in this study. The 1998 model year diesel bus equipped with an OC and fueled with low-sulfur diesel had the highest emission rates of PM and PAHs. The highest specific mutagenic activities (revertants/microg PM, or potency) and the highest mutagen emission rates (revertants/mi) were from the CNG bus in strain TA98 tested over the New York Bus (NYB) driving cycle. The 1998 model year diesel bus with DPF had the lowest VOCs, PAH, and mutagenic activity emission. In general, the NYB driving cycle had the highest emission rates (g/mi), and the Urban Dynamometer Driving Schedule (UDDS) had the lowest emission rates for all toxics tested over the three transient test cycles investigated. Also, transient emissions were, in general, higher than steady-state emissions. The emissions of toxic compounds from an in-use CNG transit bus (without an oxidation

  13. Application of multiple parallel perfused microbioreactors: Synthesis, characterization and cytotoxicity testing of the novel rare earth complexes with indole acid as a ligand.

    Science.gov (United States)

    Guan, Qing-Lin; Xing, Yong-Heng; Liu, Jing; Wei, Wen-Juan; Zhang, Rui; Wang, Xuan; Bai, Feng-Ying

    2013-11-01

    Three novel complexes, [La(phen)2(IAA)2]·NO3 (1), [Sm(phen)2(IAA)2]·NO3 (2) and [Sm(IBA)3(phen)]·phen·HNO3·H2O (3) (phen: 1,10-phenanthroline, IAA: indole-3-acetic acid, IBA: indole-3-butyric acid), were synthesized and characterized with spectroscopy (infrared and UV-visible), X-ray crystal diffraction and elemental analysis. Structural analysis revealed that each lanthanide atom in complexes 1-3 held a distorted tricapped trigonal prism geometry in a nine-coordinate mode. There were two types of coordination modes of the IAA ligand in complexes 1 and 2: a μ2-η(1):η(2) bridging mode linking two lanthanide atoms and a μ2-η(1):η(1) double monodentate bridging mode. There were three types of coordination modes of the IBA ligand: a μ2-η(1):η(1) double monodentate bridging mode, a μ1-η(2) bridging mode and a μ2-η(1):η(2) bridging mode linking two lanthanide atoms. Adjacent Sm atoms were linked via the μ2-bridging carboxylate groups of the IBA ligands to generate a binuclear building unit. The biological activity of the complexes was evaluated in human adipose tissue-derived stem cells (hADSCs) and Chang liver cells using a multiple parallel perfused microbioreactor. The results showed that cytotoxicity increased as the concentrations of complexes 1-3 increased. © 2013.

  14. Aero-acoustic design and test of a multiple splitter exhaust noise suppressor for a 0.914m diameter lift fan

    Science.gov (United States)

    Stimpert, D. L.

    1973-01-01

    A lift fan exhaust suppression system to meet future VTOL aircraft noise goals was designed and tested. The test vehicle was a 1.3 pressure ratio, 36 inch (91.44 cm) diameter lift fan with two chord rotor to stator spacing. A two splitter fan exhaust suppression system thirty inches (76.2 cm) long achieved 10 PNdB exhaust suppression in the aft quadrant compared to a design value of 20 PNdB. It was found that a broadband noise floor limited the realizable suppression. An analytical investigation of broadband noise generated by flow over the treatment surfaces provided very good agreement with the measured suppression levels and noise floor sound power levels. A fan thrust decrement of 22% was measured for the fully suppressed configuration of which 11.1% was attributed to the exhaust suppression hardware.

  15. Senior high school students’ need analysis of Three-Tier Multiple Choice (3TMC) diagnostic test about acid-base and solubility equilibrium

    Science.gov (United States)

    Ardiansah; Masykuri, M.; Rahardjo, S. B.

    2018-05-01

    Students’ conceptual understanding is the most important comprehension to obtain related comprehension. However, they held their own conception. With this need analysis, we will elicit student need of 3TMC diagnostic test to measure students’ conception about acid-base and solubility equilibrium. The research done by a mixed method using questionnaire analysis based on descriptive of quantitative and qualitative. The research subject was 96 students from 4 senior high schools and 4 chemistry teachers chosen by random sampling technique. Data gathering used a questionnaire with 10 questions for student and 28 questions for teachers. The results showed that 97% of students stated that the development this instrument is needed. In addition, there were several problems obtained in this questionnaire include learning activity, teacher’s test and guessing. In conclusion, this is necessary to develop the 3TMC instrument that can diagnose and measure the student’s conception in acid-base and solubility equilibrium.

  16. The combining of multiple hemispheric resources in learning-disabled and skilled readers' recall of words: a test of three information-processing models.

    Science.gov (United States)

    Swanson, H L

    1987-01-01

    Three theoretical models (additive, independence, maximum rule) that characterize and predict the influence of independent hemispheric resources on learning-disabled and skilled readers' simultaneous processing were tested. Predictions related to word recall performance during simultaneous encoding conditions (dichotic listening task) were made from unilateral (dichotic listening task) presentations. The maximum rule model best characterized both ability groups in that simultaneous encoding produced no better recall than unilateral presentations. While the results support the hypothesis that both ability groups use similar processes in the combining of hemispheric resources (i.e., weak/dominant processing), ability group differences do occur in the coordination of such resources.

  17. Multiple inflation

    International Nuclear Information System (INIS)

    Murphy, P.J.

    1987-01-01

    The Theory of Inflation, namely, that at some point the entropy content of the universe was greatly increased, has much promise. It may solve the puzzles of homogeneity and the creation of structure. However, no particle physics model has yet been found that can successfully drive inflation. The difficulty in satisfying the constraint that the isotropy of the microwave background places on the effective potential of prospective models is immense. In this work we have codified the requirements of such models in a most general form. We have carefully calculated the amounts of inflation the various problems of the Standard Model need for their solution. We have derived a completely model independent upper bond on the inflationary Hubble parameter. We have developed a general notation with which to probe the possibilities of Multiple Inflation. We have shown that only in very unlikely circumstances will any evidence of an earlier inflation, survive the de Sitter period of its successor. In particular, it is demonstrated that it is most unlikely that two bouts of inflation will yield high amplitudes of density perturbations on small scales and low amplitudes on large. We conclude that, while multiple inflation will be of great theoretical interest, it is unlikely to have any observational impact

  18. Assessing hydraulic connections across a complex sequence of volcanic rocks - Analysis of U-20 WW multiple-well aquifer test, Pahute Mesa, Nevada National Security Site, Nevada

    Science.gov (United States)

    Garcia, C. Amanda; Fenelon, Joseph M.; Halford, Keith J.; Reiner, Steven R.; Laczniak, Randell J.

    2011-01-01

    Groundwater beneath Pahute Mesa flows through a complexly layered sequence of volcanic rock aquifers and confining units that have been faulted into distinct structural blocks. Hydraulic property estimates of rocks and structures in this flow system are necessary to assess radionuclide migration near underground nuclear testing areas. The U.S. Geological Survey (USGS) used a 12 month (October 1, 2008— October 1, 2009) intermittent pumping schedule of well U-20 WW and continuously monitored water levels in observation wells ER-20-6 #3, UE-20bh 1, and U-20bg as a multi-well aquifer test to evaluate hydraulic connections across structural blocks, bulk hydraulic properties of volcanic rocks, and the hydraulic significance of a major fault. Measured water levels were approximated using synthetic water levels generated from an analytical model. Synthetic water levels are a summation of environmental water-level fluctuations and a Theis (1935) transform of the pumping signal from flow rate to water-level change. Drawdown was estimated by summing residual differences between measured and synthetic water levels and the Theis-transformed pumping signal from April to September 2009. Drawdown estimates were used in a three‑dimensional numerical model to estimate hydraulic properties of distinct aquifers, confining units, and a major fault.

  19. The Apache Longbow-Hellfire Missile Test at Yuma Proving Ground: Introduction and Problem Formulation for a Multiple Stressor Risk Assessment

    International Nuclear Information System (INIS)

    Efroymson, Rebecca Ann; Peterson, Mark J.; Jones, Daniel Steven; Suter, Glenn

    2008-01-01

    An ecological risk assessment was conducted at Yuma Proving Ground, Arizona, as a demonstration of the Military Ecological Risk Assessment Framework (MERAF). The focus of the assessment was a testing program at Cibola Range, which involved an Apache Longbow helicopter firing Hellfire missiles at moving targets, i.e., M60-A1 tanks. The problem formulation for the assessment included conceptual models for three component activities of the test, helicopter overflight, missile firing, and tracked vehicle movement, and two ecological endpoint entities, woody desert wash communities and desert mule deer (Odocoileus hemionus crooki) populations. An activity-specific risk assessment framework was available to provide guidance for assessing risks associated with aircraft overflights. Key environmental features of the study area include barren desert pavement and tree-lined desert washes. The primary stressors associated with helicopter overflights were sound and the view of the aircraft. The primary stressor associated with Hellfire missile firing was sound. The principal stressor associated with tracked vehicle movement was soil disturbance, and a resulting, secondary stressor was hydrological change. Water loss to washes and wash vegetation was expected to result from increased ponding, infiltration and/or evaporation associated with disturbances to desert pavement. A plan for estimating integrated risks from the three military activities was included in the problem formulation

  20. Development and Preliminary Testing of the Food Choice Priorities Survey (FCPS): Assessing the Importance of Multiple Factors on College Students' Food Choices.

    Science.gov (United States)

    Vilaro, Melissa J; Zhou, Wenjun; Colby, Sarah E; Byrd-Bredbenner, Carol; Riggsbee, Kristin; Olfert, Melissa D; Barnett, Tracey E; Mathews, Anne E

    2017-12-01

    Understanding factors that influence food choice may help improve diet quality. Factors that commonly affect adults' food choices have been described, but measures that identify and assess food choice factors specific to college students are lacking. This study developed and tested the Food Choice Priorities Survey (FCPS) among college students. Thirty-seven undergraduates participated in two focus groups ( n = 19; 11 in the male-only group, 8 in the female-only group) and interviews ( n = 18) regarding typical influences on food choice. Qualitative data informed the development of survey items with a 5-point Likert-type scale (1 = not important, 5 = extremely important). An expert panel rated FCPS items for clarity, relevance, representativeness, and coverage using a content validity form. To establish test-retest reliability, 109 first-year college students completed the 14-item FCPS at two time points, 0-48 days apart ( M = 13.99, SD = 7.44). Using Cohen's weighted κ for responses within 20 days, 11 items demonstrated moderate agreement and 3 items had substantial agreement. Factor analysis revealed a three-factor structure (9 items). The FCPS is designed for college students and provides a way to determine the factors of greatest importance regarding food choices among this population. From a public health perspective, practical applications include using the FCPS to tailor health communications and behavior change interventions to factors most salient for food choices of college students.

  1. VMA Test

    Science.gov (United States)

    ... spasms and rapid eye movements referred to as "dancing eyes, dancing feet." The VMA test may also be ordered ... a pheochromocytoma or neuroblastoma? People with a family history of multiple endocrine neoplasia (MEN2), a genetic condition ...

  2. Effects of Creatine and Sodium Bicarbonate Coingestion on Multiple Indices of Mechanical Power Output During Repeated Wingate Tests in Trained Men.

    Science.gov (United States)

    Griffen, Corbin; Rogerson, David; Ranchordas, Mayur; Ruddock, Alan

    2015-06-01

    This study investigated the effects of creatine and sodium bicarbonate coingestion on mechanical power during repeated sprints. Nine well-trained men (age = 21.6 ± 0.9 yr, stature = 1.82 ± 0.05 m, body mass = 80.1 ±12.8 kg) participated in a double-blind, placebo-controlled, counterbalanced, crossover study using six 10-s repeated Wingate tests. Participants ingested either a placebo (0.5 g·kg(-1) of maltodextrin), 20 g·d(-1) of creatine monohydrate + placebo, 0.3 g·kg(-1) of sodium bicarbonate + placebo, or coingestion + placebo for 7 days, with a 7-day washout between conditions. Participants were randomized into two groups with a differential counterbalanced order. Creatine conditions were ordered first and last. Indices of mechanical power output (W), total work (J) and fatigue index (W·s(-1)) were measured during each test and analyzed using the magnitude of differences between groups in relation to the smallest worthwhile change in performance. Compared with placebo, both creatine (effect size (ES) = 0.37-0.83) and sodium bicarbonate (ES = 0.22-0.46) reported meaningful improvements on indices of mechanical power output. Coingestion provided small meaningful improvements on indices of mechanical power output (W) compared with sodium bicarbonate (ES = 0.28-0.41), but not when compared with creatine (ES = -0.21-0.14). Coingestion provided a small meaningful improvement in total work (J; ES = 0.24) compared with creatine. Fatigue index (W·s(-1)) was impaired in all conditions compared with placebo. In conclusion, there was no meaningful additive effect of creatine and sodium bicarbonate coingestion on mechanical power during repeated sprints.

  3. PathMAPA: a tool for displaying gene expression and performing statistical tests on metabolic pathways at multiple levels for Arabidopsis

    Directory of Open Access Journals (Sweden)

    Ma Ligeng

    2003-11-01

    Full Text Available Abstract Background To date, many genomic and pathway-related tools and databases have been developed to analyze microarray data. In published web-based applications to date, however, complex pathways have been displayed with static image files that may not be up-to-date or are time-consuming to rebuild. In addition, gene expression analyses focus on individual probes and genes with little or no consideration of pathways. These approaches reveal little information about pathways that are key to a full understanding of the building blocks of biological systems. Therefore, there is a need to provide useful tools that can generate pathways without manually building images and allow gene expression data to be integrated and analyzed at pathway levels for such experimental organisms as Arabidopsis. Results We have developed PathMAPA, a web-based application written in Java that can be easily accessed over the Internet. An Oracle database is used to store, query, and manipulate the large amounts of data that are involved. PathMAPA allows its users to (i upload and populate microarray data into a database; (ii integrate gene expression with enzymes of the pathways; (iii generate pathway diagrams without building image files manually; (iv visualize gene expressions for each pathway at enzyme, locus, and probe levels; and (v perform statistical tests at pathway, enzyme and gene levels. PathMAPA can be used to examine Arabidopsis thaliana gene expression patterns associated with metabolic pathways. Conclusion PathMAPA provides two unique features for the gene expression analysis of Arabidopsis thaliana: (i automatic generation of pathways associated with gene expression and (ii statistical tests at pathway level. The first feature allows for the periodical updating of genomic data for pathways, while the second feature can provide insight into how treatments affect relevant pathways for the selected experiment(s.

  4. Multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain. Pt. 2

    International Nuclear Information System (INIS)

    1991-03-01

    BIOMOVS is an international study for testing and validating model predictions of the transfer of radionuclides and rare stable elements through the biosphere. The BIOMOVS A4 scenario was designed to test model prediction of the transfer of I-131 and Cs-137 from the atmosphere via pasture vegetation to milk and of the Cs-137 transfer from air to beef (via vegetation) and grain. This document is an appendix to the A4 report. It includes tables and figures of time-integrated results, a summary of a statistical analysis of time-dependent and representative figures of time-dependent results. The quantities to be predicted in this scenario were wet, dry and total deposition (Bq m -2 ) of I-131 and Cs-137, contamination of vegetation (Bq kg -1 d.w.), milk (Bq L -1 ), beef and grain (Bq kg -1 ). While with steady state models only time-integrated results for vegetation, milk and beef could be calculated, these quantities also were requested as time-series from users of dynamic models. A detailed description of the participating models is given in Appendix 3, while all collected observations are documented in Appendix 2 of the A4 report. A diskette with all observed data can be obtained from the Swedish National Institute of Radiation Protection, SSI, or from Harry Koehler, IAEA, Vienna, Austria. For time-integrated P/Os, graphs for all locations and all models and sometimes subsets of these are provided. For time-series, graphs are enclosed for the observations and some model results. These values are calculated across locations and across models for time-integrated predictions and for the P/O of entire time-series and subsets of these for the time-dependent predictions. (au)

  5. Usefulness of laser-evoked potentials and quantitative sensory testing in the diagnosis of neuropathic spinal cord injury pain: a multiple case study.

    Science.gov (United States)

    Landmann, G; Berger, M F; Stockinger, L; Opsommer, E

    2017-06-01

    A retrospective study. The aim of this study was to investigate the contribution of laser-evoked potentials (LEPs) and quantitative sensory testing (QST) to the diagnosis of neuropathic pain in patients with spinal cord injury (SCI) and inconclusive magnetic resonance imaging (MRI) findings. A multidisciplinary pain center. QST (DFNS protocol) and Tm-YAG-laser stimulation of the skin were applied within the pain site corresponding with dermatomes of altered sensation. Available MRI scans were reviewed. Thirteen individuals (50±16 years) with SCI were examined. In four cases with no detectable neural lesion on MRI, all QST but three LEP were abnormal. In four patients with poorly defined spinal lesion on MRI, all QST but three LEP only were abnormal. In four cases where pain was not matching adequately with MRI lesions, all patients had abnormal LEP and QST. In one patient showing a spinal cord atrophy, LEP was normal but QST was abnormal. Findings supported the diagnoses at-level (n=5) and below-level (n=8) SCI pain. Spinothalamic tract function assessed by LEP was normal in three cases, but QST was abnormal in all cases. As QST is a psychophysical examination depending on patient cooperation, we suggest that the combination of QST and LEP might be a valuable diagnostic tool to detect lesions of the somatosensory system in a subgroup of patients with neuropathic spinal cord injury pain and inconclusive MRI findings.

  6. Assessing flow paths in a karst aquifer based on multiple dye tracing tests using stochastic simulation and the MODFLOW-CFP code

    Science.gov (United States)

    Assari, Amin; Mohammadi, Zargham

    2017-09-01

    Karst systems show high spatial variability of hydraulic parameters over small distances and this makes their modeling a difficult task with several uncertainties. Interconnections of fractures have a major role on the transport of groundwater, but many of the stochastic methods in use do not have the capability to reproduce these complex structures. A methodology is presented for the quantification of tortuosity using the single normal equation simulation (SNESIM) algorithm and a groundwater flow model. A training image was produced based on the statistical parameters of fractures and then used in the simulation process. The SNESIM algorithm was used to generate 75 realizations of the four classes of fractures in a karst aquifer in Iran. The results from six dye tracing tests were used to assign hydraulic conductivity values to each class of fractures. In the next step, the MODFLOW-CFP and MODPATH codes were consecutively implemented to compute the groundwater flow paths. The 9,000 flow paths obtained from the MODPATH code were further analyzed to calculate the tortuosity factor. Finally, the hydraulic conductivity values calculated from the dye tracing experiments were refined using the actual flow paths of groundwater. The key outcomes of this research are: (1) a methodology for the quantification of tortuosity; (2) hydraulic conductivities, that are incorrectly estimated (biased low) with empirical equations that assume Darcian (laminar) flow with parallel rather than tortuous streamlines; and (3) an understanding of the scale-dependence and non-normal distributions of tortuosity.

  7. Multiple model testing using Chernobyl fallout data of I-131 in forage and milk and Cs-137 in forage, milk, beef and grain. Pt. 1

    International Nuclear Information System (INIS)

    Koehler, H.; Peterson, S.R.; Owen Hoffman, F.

    1991-03-01

    Comprehensive measurements of I-131 and Cs-137 in the environment after the Chernobyl accident provided a unique opportunity for the collection of environmental transfer data sets. These come from 13 locations in the northern hemisphere which experienced levels of contamination that spanned approximately three orders of magnitude. Data have been compiled for radionuclide concentrations in air, rain, pasture vegetation, milk, beef and grain. In addition background information has been collated for factors such as prevailing meteorological conditions, location description, and local agricultural practices. Participants were asked to predict radionuclide concentrations in forage, milk, beef and grain from radionuclide concentrations in air, the daily amounts of precipitation and other pertinent information. This was a blind test in that the locations to which the input data referred were not revealed to the participants until after they had submitted their predictions. Twenty-three models were involved in the study. This report compares observations and predictions for deposition, time- integrated concentrations in forage, milk, beef and grain, to help assess understanding of individual processes, time-dependent concentrations in forage, milk and beef. In general, predictions of time-integrated concentration of I-131 and Cs-137 in forage, milk (normalized for forage) and beef are within a factor of 10 of the observations. About 50% of the predictions of I-131 and Cs-137 in forage and just over 30% of the predictions of those nuclides in milk (normalized for forage) fall within a factor of 2 of the observations. Documentation of the measurements, models, methods of analysis and model results is presented in the appendices. (au) (75 refs.)

  8. Ultrashort courses of adjuvant breast radiotherapy: wave of the future or a fool's errand?

    Science.gov (United States)

    Khan, Atif J; Dale, Roger G; Arthur, Douglas W; Haffty, Bruce G; Todor, Dorin A; Vicini, Frank A

    2012-04-15

    In accelerated partial breast irradiation (APBI), the most commonly used fractionation schemes include 340 or 385 centigrays delivered in a twice daily administration. A further progression of the APBI literature has been the recent interest in extremely short courses of adjuvant radiotherapy, usually delivered by intraoperative radiotherapy techniques. This newer area of single-fraction radiotherapy approaches remains highly contentious. In particular, the recently reported TARGIT trial has been the subject of both praise and scorn, and a critical examination of the trial data and the underlying hypotheses is warranted. Short-term outcomes of the related Italian ELIOT approach have also been reported. Although the assumptions of linear quadratic formalism are likely to hold true in the range of 2 to 8 grays, equating different schedules beyond this range is problematic. A major problem of current single-fraction approaches is that the treatment doses are chosen empirically, or are based on tolerability, or on the physical dose delivery characteristics of the chosen technology rather than radiobiological rationale. This review article summarizes the current data on ultrashort courses of adjuvant breast radiotherapy and highlights both the promise and the potential pitfalls of the abbreviated treatment. Copyright © 2011 American Cancer Society.

  9. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  10. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen; Schuster, Gerard T.

    2017-01-01

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  11. Code verification and Y2K testing, calibration, testing, and installation of the radionuclide assay system-photon (RAS-P) at multiple sites for the Savannah River Site

    International Nuclear Information System (INIS)

    Hodge, C.A.

    2000-01-01

    The Radionuclide Assay System - Photon (RAS-P) is a near-field, transmission-corrected assay system developed for measurement of the actinide content of relatively homogeneous waste generated by facility operations. It is intended for use by facility operations personnel, and has features to enhance its usefulness and efficiency. These include multinuclide assay capability, automatic (off-shift) collection of background and straight-through transmission source data, enforcement of measurement control requirements, Go-NoGo or Assay modes, password protection, and reporting of total fissile gram equivalent values. System hardware consists of a shielded high-resolution germanium detector, a turntable, a shielded transmission source and shutter assembly, and a desktop computer and laser printer mounted on a compact frame. RAS-P was designed to assay the contents of cylindrical containers up to 30 inches diameter by 32 inches high, boxes up to 30 inches diagonal by 32 inches high, and HE PA filters up to 2 x 2 x 1 feet. Prior to installation at the Savannah River Site (SRS), code validation, system performance, and assurance against Y2K effects all were confirmed. Code validation was accomplished using spreadsheet calculations that were independent of the original code to calculate intermediate and final result produced by RAS-P. System testing was performed by repeated operation of the instrument under all required circumstances. Y2K testing was performed simultaneously with code validation following a protocol prescribed by the SRS Y2K subcommittee that required assays with dates varying throughout the expected useful life of the RAS-P, particularly those bracketing Y2K boundaries. Performance history has been compiled demonstrating reliability (system availability), diversability (the ability to alter assay parameters and obtain results quickly), and measurement control characteristics

  12. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  13. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-01-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (μg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r = 0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r = 0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA

  14. Multiple sclerosis and birth order.

    Science.gov (United States)

    James, W H

    1984-01-01

    Studies on the birth order of patients with multiple sclerosis have yielded contradictory conclusions. Most of the sets of data, however, have been tested by biased tests. Data that have been submitted to unbiased tests seem to suggest that cases are more likely to occur in early birth ranks. This should be tested on further samples and some comments are offered on how this should be done. PMID:6707558

  15. Multiple sclerosis and birth order.

    OpenAIRE

    James, W H

    1984-01-01

    Studies on the birth order of patients with multiple sclerosis have yielded contradictory conclusions. Most of the sets of data, however, have been tested by biased tests. Data that have been submitted to unbiased tests seem to suggest that cases are more likely to occur in early birth ranks. This should be tested on further samples and some comments are offered on how this should be done.

  16. Test and evaluation of multiple lambda-sensors for use in combustion gases; Multi {lambda}-sond - Utveckling och test av enkel teknik foer O{sub 2}-maetning oever tvaersnitt

    Energy Technology Data Exchange (ETDEWEB)

    Kallner, Per; Gaardman, Lennart; Engel, Erik [Vattenfall Utveckling AB, Stockholm (Sweden)

    2001-03-01

    Fluctuations and zones with fuel rich conditions are the main causes of CO-emissions and abnormal deposit formation. This project was initiated to try and trace such disturbances. 'Multi-sensor-probes' is a quick and easy way of mapping fluctuations in many points along an axis simultaneously. This project is concentrated on such measurement systems, based on lambda({lambda})-sensor technology. The project was run in a few steps: - The use of {lambda}-sensors for O{sub 2} measurements in hot flue gases (>800 deg C), - Development and testing of probe-constructions for multi-point measurements, and - Performing measurement series in Vaermeforsk-related boilers, to identify fluctuations and fuel rich zones. This project shows how standard {lambda}-sensors can be utilised also in hot flue gases. In-situ measurements with a single-sensor probe is demonstrated in CFB, PF and grate boilers. It is a water-cooled probe, with the {lambda}-sensor mounted inside the tip of the probe. To perform multi-point measurements with the standard {lambda}-sensors, an extractive probe design had to be developed. With the standard {lambda}-sensors no sensible design for multi-point in-situ measurements could be found. A way to achieve such designs would be development of {lambda}-sensors where the zirconium oxide measurement cell is separated from the electrical wiring. This would give much smaller pieces to include in the probe and especially solve the problem of low temperature demand for the parts just behind the measurement cell in standard {lambda}-sensors. This could mean a multi-probe cooled to just 500-600 deg C. The construction of the extractive multi-probe tested in this project suffered from leakage in the suction lines when exposed inside the PF boiler. A proposed design with better function in this aspect is presented in this report. The results show that by combining a cooled probe-design with standard {lambda}-sensor components a tool for measurements of O{sub 2

  17. Statistical Power in Evaluations That Investigate Effects on Multiple Outcomes: A Guide for Researchers

    Science.gov (United States)

    Porter, Kristin E.

    2018-01-01

    Researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple testing procedures (MTPs) are statistical…

  18. Multiple Input - Multiple Output (MIMO) SAR

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort will research and implement advanced Multiple-Input Multiple-Output (MIMO) Synthetic Aperture Radar (SAR) techniques which have the potential to improve...

  19. Multiples waveform inversion

    KAUST Repository

    Zhang, Dongliang

    2013-01-01

    To increase the illumination of the subsurface and to eliminate the dependency of FWI on the source wavelet, we propose multiples waveform inversion (MWI) that transforms each hydrophone into a virtual point source with a time history equal to that of the recorded data. These virtual sources are used to numerically generate downgoing wavefields that are correlated with the backprojected surface-related multiples to give the migration image. Since the recorded data are treated as the virtual sources, knowledge of the source wavelet is not required, and the subsurface illumination is greatly enhanced because the entire free surface acts as an extended source compared to the radiation pattern of a traditional point source. Numerical tests on the Marmousi2 model show that the convergence rate and the spatial resolution of MWI is, respectively, faster and more accurate then FWI. The potential pitfall with this method is that the multiples undergo more than one roundtrip to the surface, which increases attenuation and reduces spatial resolution. This can lead to less resolved tomograms compared to conventional FWI. The possible solution is to combine both FWI and MWI in inverting for the subsurface velocity distribution.

  20. L’effet de la personnalité sur la performance des étudiants universitaires en sciences de l’administration à l’examen écrit, au test à choix multiple et aux travaux pratiques

    Directory of Open Access Journals (Sweden)

    Sawsen Lakhal

    2017-03-01

    Full Text Available Plusieurs programmes universitaires en sciences de l’administration au Canada ont implanté des réformes majeures, suite aux demandes des organismes d’agrément tels que l’Association to Advance Collegiate Schools of Business (AACSB. Conséquemment, de plus en plus de méthodes d’évaluation des apprentissages sont utilisées. Toutefois, l’introduction de ces méthodes dans les programmes d’études pourrait engendrer des biais aux résultats de l’évaluation des apprentissages. L’étude des facteurs pouvant avoir un effet sur la performance des étudiants aux différentes méthodes d’évaluation devient pertinente dans ce contexte. Ainsi, l’objectif de cette étude consiste à vérifier si la personnalité telle que définie par le modèle des cinq facteurs influence la performance à l’examen écrit, au test à choix multiples et aux travaux pratiques. Deux variables contrôle, le genre et l’âge, sont inclus dans les analyses. Un échantillon de 378 étudiants inscrits à un cours de premier cycle universitaire en sciences de l’administration a répondu à un questionnaire en ligne. Les résultats des analyses des régressions linéaires multiples indiquent que ce ne sont pas toujours les mêmes facteurs de la personnalité qui sont sollicités d’une méthode d’évaluation à l’autre, indiquant l’existence potentielle de biais à l’évaluation des apprentissages. Ces résultats sont discutés au regard de la littérature plus large dans le domaine et touchant à d’autres programmes d’études universitaires. In Canada, a number of university programs in business administration have imbedded major reforms, following requests from accreditation bodies such as the Association to Advance Collegiate Schools of Business (AACSB. Consequently, more and more learning assessment methods are used. However, the introduction of these methods in curricula could lead to bias to the results of learning assessment. In

  1. Allergenicity evaluation of p-chloro-m-cresol and p-chloro-m-xylenol by non-radioactive murine local lymph-node assay and multiple-dose guinea pig maximization test

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2003-01-01

    p-Chloro-m-cresol (PCMC) and p-chloro-m-xylenol (PCMX) are known to cause allergic contact dermatitis. For risk assessment of skin sensitizers, information on dose-response profiles in the induction and elicitation phases and cross-reactivity with analogous chemicals are important. In the non-radioactive local lymph-node assay (LLNA) using 5-bromo-2'-deoxyuridine instead of 3 H-methyl thymidine, significant effect on lymph node cell proliferation was detected at 10% PCMC and 25% PCMX, while in the multiple-dose guinea pig maximization test (GPMT) at least one animal tested in the group was sensitized at a 5 ppm induction dose of either chemical. When mean skin reaction score in an animal group maximally sensitized with each allergen with the GPMT was plotted against log challenge concentration, linear regression lines with high correlations were obtained in both cases. The calculated elicitation threshold was lower for PCMC than PCMX. The area under the linear regression line between the threshold point and 1% of the elicitation concentration, another index of relative elicitation potency, was also greater for PCMC. Bidirectional cross-reactivity between PCMX and PCMC was detected in the GPMT. PCMC was thus identified in both LLNA and GPMT as a stronger sensitizer than PCMX in both the induction and elicitation phases. These results suggest that the non-radioactive LLNA is a simple and useful method for evaluating allergenicity in the induction phase, while the GPMT using a maximally sensitized animal group is more suitable for assessing the dose-response profile and cross-reactivity in the elicitation phase

  2. INDIA: Photon multiplicity detector

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to

  3. INDIA: Photon multiplicity detector

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-01-15

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to 25 mm

  4. Multiple Sclerosis After Infectious Mononucleosis

    DEFF Research Database (Denmark)

    Nielsen, Trine Rasmussen; Rostgaard, Klaus; Nielsen, Nete Munk

    2007-01-01

    BACKGROUND: Infectious mononucleosis caused by the Epstein-Barr virus has been associated with increased risk of multiple sclerosis. However, little is known about the characteristics of this association. OBJECTIVE: To assess the significance of sex, age at and time since infectious mononucleosis......, and attained age to the risk of developing multiple sclerosis after infectious mononucleosis. DESIGN: Cohort study using persons tested serologically for infectious mononucleosis at Statens Serum Institut, the Danish Civil Registration System, the Danish National Hospital Discharge Register, and the Danish...... Multiple Sclerosis Registry. SETTING: Statens Serum Institut. PATIENTS: A cohort of 25 234 Danish patients with mononucleosis was followed up for the occurrence of multiple sclerosis beginning on April 1, 1968, or January 1 of the year after the diagnosis of mononucleosis or after a negative Paul...

  5. Growth hormone/IGF-1 axis longitudinal evaluation in clinically isolated syndrome patients on interferon β-1b therapy: stimulation tests and correlations with clinical and radiological conversion to multiple sclerosis.

    Science.gov (United States)

    Lanzillo, R; Di Somma, C; Quarantelli, M; Carotenuto, A; Pivonello, C; Moccia, M; Cianflone, A; Marsili, A; Puorro, G; Saccà, F; Russo, C V; De Luca Picione, C; Ausiello, F; Colao, A; Brescia Morra, V

    2017-02-01

    Growth hormone (GH)/insulin-like growth factor 1 (IGF-1) axis abnormalities in multiple sclerosis (MS) suggest their role in its pathogenesis. Interferon β (IFN-β) efficacy could be mediated also by an increase of IGF-1 levels. A 2-year longitudinal study was performed to estimate the prevalence of GH and/or IGF-1 deficiency in clinically isolated syndrome (CIS) patients and their correlation with conversion to MS in IFN treated patients. Clinical and demographic features of CIS patients were collected before the start of IFN-β-1b. IGF-1 levels and GH response after arginine and GH releasing hormone + arginine stimulation tests were assessed. Clinical and magnetic resonance imaging evaluations were performed at baseline, 1 year and 2 years. Thirty CIS patients (24 female) were enrolled. At baseline, four patients (13%) showed a hypothalamic GH deficiency (GHD), whilst no one had a pituitary GHD. Baseline demographic, clinical and radiological data were not related to GHD, whilst IGF-1 levels were inversely related to age (P IGF-1 serum mean levels were not significantly modified after 1 and 2 years of treatment in the whole group, although 3/4 GHD patients experienced a normalization of GH levels, whilst one dropped out. After 2 years of treatment 13/28 (46%) patients converted to MS. The presence of GHD and GH and IGF-1 levels were not predictive of relapses, new T2 lesions or conversion occurrence. Growth hormone/IGF-1 axis function was found to be frequently altered in CIS patients, but this was not related to MS conversion. Patients experienced an improvement of GHD during IFN therapy. Longer follow-up is necessary to assess its impact on disease progression. © 2016 EAN.

  6. On Multiple Appearances

    DEFF Research Database (Denmark)

    Bork Petersen, Franziska

    2012-01-01

    reduction and epoché to focus on how dancing bodies appear in a stage context. To test these tools’ ability to explore dancing bodies from a third-person perspective, I analyse the Danish choreographer Kitt Johnson’s solo performance Drift (2011) - focussing on her shifting physical appearance. While...... phenomenology helps me to describe the multiple and radically different guises that Johnson assumes in her piece, my analysis, ultimately, does not aim to distil a truer, more real being from her appearances as is often the case in phenomenological philosophy. I complement my analytical approach...... with the Deleuzian notion of becoming animal and suggest that Johnson stages what could, in Judith Butler’s terms, be called a critical contingency of bodily appearance....

  7. Multiple-Ring Digital Communication Network

    Science.gov (United States)

    Kirkham, Harold

    1992-01-01

    Optical-fiber digital communication network to support data-acquisition and control functions of electric-power-distribution networks. Optical-fiber links of communication network follow power-distribution routes. Since fiber crosses open power switches, communication network includes multiple interconnected loops with occasional spurs. At each intersection node is needed. Nodes of communication network include power-distribution substations and power-controlling units. In addition to serving data acquisition and control functions, each node acts as repeater, passing on messages to next node(s). Multiple-ring communication network operates on new AbNET protocol and features fiber-optic communication.

  8. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain

    2014-12-04

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green\\'s function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green\\'s function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green\\'s function and renders the higher order internal multiple image for display on a display device.

  9. MultipleColposcopyJCO

    Science.gov (United States)

    Performing multiple biopsies during a procedure known as colposcopy—visual inspection of the cervix—is more effective than performing only a single biopsy of the worst-appearing area for detecting cervical cancer precursors. This multiple biopsy approach

  10. Salmonella Infections - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Salmonella Infections URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Salmonella Infections - Multiple Languages To use the sharing features ...

  11. Health Literacy - Multiple Languages

    Science.gov (United States)

    ... Here: Home → Multiple Languages → All Health Topics → Health Literacy URL of this page: https://medlineplus.gov/languages/ ... W XYZ List of All Topics All Health Literacy - Multiple Languages To use the sharing features on ...

  12. Cosmetic Dentistry - Multiple Languages

    Science.gov (United States)

    ... Here: Home → Multiple Languages → All Health Topics → Cosmetic Dentistry URL of this page: https://medlineplus.gov/languages/ ... W XYZ List of All Topics All Cosmetic Dentistry - Multiple Languages To use the sharing features on ...

  13. Atrial Fibrillation - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Atrial Fibrillation URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Atrial Fibrillation - Multiple Languages To use the sharing features on ...

  14. Zika Virus - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Zika Virus URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Zika Virus - Multiple Languages To use the sharing features on ...

  15. Elder Abuse - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Elder Abuse URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Elder Abuse - Multiple Languages To use the sharing features on ...

  16. Herbal Medicine - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Herbal Medicine URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Herbal Medicine - Multiple Languages To use the sharing features on ...

  17. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain; Alkhalifah, Tariq

    2014-01-01

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green's function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green's function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green's function and renders the higher order internal multiple image for display on a display device.

  18. Domestic Violence - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Domestic Violence URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Domestic Violence - Multiple Languages To use the sharing features on ...

  19. Multiple Primary Tumors

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Multiple primary tumors occur in clinical practice causing diagnostic dilemma. It is not very .... was estrogen receptor negative, progesterone receptor negative, and ... cervical, ovarian, and urinary bladder cancers. Multiple.

  20. Diabetic Foot - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Diabetic Foot URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Diabetic Foot - Multiple Languages To use the sharing features on ...

  1. Child Abuse - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Child Abuse URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Child Abuse - Multiple Languages To use the sharing features on ...

  2. Fatigue and Multiple Sclerosis

    Science.gov (United States)

    ... to navigation Skip to content Menu Navigation National Multiple Sclerosis Society Sign In In Your Area Donate Donate ... of MS What Causes MS? Who Gets MS? Multiple Sclerosis FAQs Types of MS Related Conditions Symptoms & Diagnosis ...

  3. Rotavirus Infections - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Rotavirus Infections URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Rotavirus Infections - Multiple Languages To use the sharing features ...

  4. Dtest Testing Software

    Science.gov (United States)

    Jain, Abhinandan; Cameron, Jonathan M.; Myint, Steven

    2013-01-01

    This software runs a suite of arbitrary software tests spanning various software languages and types of tests (unit level, system level, or file comparison tests). The dtest utility can be set to automate periodic testing of large suites of software, as well as running individual tests. It supports distributing multiple tests over multiple CPU cores, if available. The dtest tool is a utility program (written in Python) that scans through a directory (and its subdirectories) and finds all directories that match a certain pattern and then executes any tests in that directory as described in simple configuration files.

  5. Neutron Multiplicity Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine Chiyoko [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    Neutron multiplicity measurements are widely used for nondestructive assay (NDA) of special nuclear material (SNM). When combined with isotopic composition information, neutron multiplicity analysis can be used to estimate the spontaneous fission rate and leakage multiplication of SNM. When combined with isotopic information, the total mass of fissile material can also be determined. This presentation provides an overview of this technique.

  6. Making the Most of Multiple Choice

    Science.gov (United States)

    Brookhart, Susan M.

    2015-01-01

    Multiple-choice questions draw criticism because many people perceive they test only recall or atomistic, surface-level objectives and do not require students to think. Although this can be the case, it does not have to be that way. Susan M. Brookhart suggests that multiple-choice questions are a useful part of any teacher's questioning repertoire…

  7. 9 CFR 113.7 - Multiple fractions.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Multiple fractions. 113.7 Section 113... § 113.7 Multiple fractions. (a) When a biological product contains more than one immunogenic fraction, the completed product shall be evaluated by tests applicable to each fraction. (b) When similar...

  8. Multiplicity in Early Stellar Evolution

    Science.gov (United States)

    Reipurth, B.; Clarke, C. J.; Boss, A. P.; Goodwin, S. P.; Rodríguez, L. F.; Stassun, K. G.; Tokovinin, A.; Zinnecker, H.

    Observations from optical to centimeter wavelengths have demonstrated that multiple systems of two or more bodies is the norm at all stellar evolutionary stages. Multiple systems are widely agreed to result from the collapse and fragmentation of cloud cores, despite the inhibiting influence of magnetic fields. Surveys of class 0 protostars with millimeter interferometers have revealed a very high multiplicity frequency of about 2/3, even though there are observational difficulties in resolving close protobinaries, thus supporting the possibility that all stars could be born in multiple systems. Near-infrared adaptive optics observations of class I protostars show a lower binary frequency relative to the class 0 phase, a declining trend that continues through the class II/III stages to the field population. This loss of companions is a natural consequence of dynamical interplay in small multiple systems, leading to ejection of members. We discuss observational consequences of this dynamical evolution, and its influence on circumstellar disks, and we review the evolution of circumbinary disks and their role in defining binary mass ratios. Special attention is paid to eclipsing PMS binaries, which allow for observational tests of evolutionary models of early stellar evolution. Many stars are born in clusters and small groups, and we discuss how interactions in dense stellar environments can significantly alter the distribution of binary separations through dissolution of wider binaries. The binaries and multiples we find in the field are the survivors of these internal and external destructive processes, and we provide a detailed overview of the multiplicity statistics of the field, which form a boundary condition for all models of binary evolution. Finally, we discuss various formation mechanisms for massive binaries, and the properties of massive trapezia.

  9. Neutron multiplication measurement instrument

    International Nuclear Information System (INIS)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1983-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results

  10. The in-situ decontamination of sand and gravel aquifers by chemically enhanced solubilization of multiple-compound DNAPLs with surfactant solutions: Phase 1 -- Laboratory and pilot field-scale testing and Phase 2 -- Solubilization test and partitioning and interwell tracer tests. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-24

    Laboratory, numerical simulation, and field studies have been conducted to assess the potential use of micellar-surfactant solutions to solubilize chlorinated solvents contaminating sand and gravel aquifers. Ninety-nine surfactants were screened for their ability to solubilize trichloroethene (TCE), perchloroethylene (PCE), and carbon tetrachloride (CTET). The field test was conducted in the alluvial aquifer which is located 20 to 30 meters beneath a vapor degreasing operation at Paducah Gaseous Diffusion Plant. This aquifer has become contaminated with TCE due to leakage of perhaps 40,000 liters of TCE, which has generated a plume of dissolved TCE extending throughout an area of approximately 3 km{sup 2} in the aquifer. Most of the TCE is believed to be present in the overlying lacustrine deposits and in the aquifer itself as a dense, non-aqueous phase liquid, or DNAPL. The objective of the field test was to assess the efficacy of the surfactant for in situ TCE solubilization. Although the test demonstrated that sorbitan monooleate was unsuitable as a solubilizer in this aquifer, the single-well test was demonstrated to be a viable method for the in situ testing of surfactants or cosolvents prior to proceeding to full-scale remediation.

  11. The in-situ decontamination of sand and gravel aquifers by chemically enhanced solubilization of multiple-compound DNAPLs with surfactant solutions. Phase 1: Laboratory and pilot field-scale testing. Phase 2: Solubilization test and partitioning interwell tracer tests. Final report

    International Nuclear Information System (INIS)

    1997-01-01

    Laboratory, numerical simulation, and field studies have been conducted to assess the potential use of micellar-surfactant solutions to solubilize chlorinated solvents contaminating sand and gravel aquifers. Ninety-nine surfactants were screened for their ability to solubilize trichloroethene (TCE), perchloroethylene (PCE), and carbon tetrachloride (CTET). The field test was conducted in the alluvial aquifer which is located 20 to 30 meters beneath a vapor degreasing operation at Paducah Gaseous Diffusion Plant. This aquifer has become contaminated with TCE due to leakage of perhaps 40,000 liters of TCE, which has generated a plume of dissolved TCE extending throughout an area of approximately 3 km 2 in the aquifer. Most of the TCE is believed to be present in the overlying lacustrine deposits and in the aquifer itself as a dense, non-aqueous phase liquid, or DNAPL. The objective of the field test was to assess the efficacy of the surfactant for in situ TCE solubilization. Although the test demonstrated that sorbitan monooleate was unsuitable as a solubilizer in this aquifer, the single-well test was demonstrated to be a viable method for the in situ testing of surfactants or cosolvents prior to proceeding to full-scale remediation

  12. Neuropsychological testing.

    Science.gov (United States)

    Zucchella, Chiara; Federico, Angela; Martini, Alice; Tinazzi, Michele; Bartolo, Michelangelo; Tamburin, Stefano

    2018-06-01

    Neuropsychological testing is a key diagnostic tool for assessing people with dementia and mild cognitive impairment, but can also help in other neurological conditions such as Parkinson's disease, stroke, multiple sclerosis, traumatic brain injury and epilepsy. While cognitive screening tests offer gross information, detailed neuropsychological evaluation can provide data on different cognitive domains (visuospatial function, memory, attention, executive function, language and praxis) as well as neuropsychiatric and behavioural features. We should regard neuropsychological testing as an extension of the neurological examination applied to higher order cortical function, since each cognitive domain has an anatomical substrate. Ideally, neurologists should discuss the indications and results of neuropsychological assessment with a clinical neuropsychologist. This paper summarises the rationale, indications, main features, most common tests and pitfalls in neuropsychological evaluation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Cognitive deficits in multiple sclerosis

    DEFF Research Database (Denmark)

    Lund, H; Jønsson, A; Andresen, Jesper Graubæk

    2012-01-01

    of the cognitive impairment seen in MS and constitute a supplement to traditional measurement of T2 lesion volume. Materials and Methods - Fifty patients with clinically definite MS were included (38 women, 12 men). Patients were MR scanned, neuropsychologically tested, and evaluated clinically with the Kurtzke......Objectives - Although disease load in multiple sclerosis (MS) often is based on T2 lesion volumes, the changes in T2 of normal appearing brain tissue (NABT) are rarely considered. By means of magnetic resonance, (MR) we retrospectively investigated whether T2 changes in NABT explain part...... Expanded Disability Status Scale (EDSS) and the Multiple Sclerosis Impairment Scale (MSIS). Voxel-wise T2 estimates and total T2 lesion volume were tested for correlations with eight cognitive domains, a general cognitive dysfunction factor (CDF), and the two clinical scales. Results - We found distinct...

  14. Introduction: multiple myeloma.

    Science.gov (United States)

    Cook, Richard

    2008-09-01

    Multiple myeloma (MM) is the most common type of primary bone tumor, affecting approximately 50,000 patients in the United States. Although it is currently not curable, recent advancements in treatment are bringing myeloma closer to becoming a chronic disease instead of a terminal illness. To better understand the prevalence of MM as well as provide an overview of the costs associated with treatment. The goals of treatment in MM include eradicating all evidence of disease, controlling disease to prevent damage to target organs, preserving normal function and quality of life, relieving pain, and managing myeloma that is in remission. To achieve these goals, treatment must be individually tailored for each patient based on the patient's age, overall health status, symptoms, and laboratory test results. Advancements in the understanding of the pathogenesis of myeloma and the role of genetic mutations are leading to a new standard of treatment. Advancements in diagnostic technology, such as cytogenetic testing, are also being used to tailor treatment for each individual to work toward achieving better response rates, longer periods of remission, and improved quality of life. Increased costs associated with the improved therapies being used to treat MM, and the comorbid conditions associated with the disease, present a challenge to managed care. Health plans and formulary decision makers need to better understand the complexity of therapy to best use resources. The economic burden to the patient must also be considered when developing treatment strategies. Better understanding of the pathophysiology of MM, including the role of cytogenetics, is leading to the development and use of novel agents and treatment options. Head-to-head studies comparing treatments must be performed to best balance the costs associated with treatment and the benefits of improved survival rates and maintaining quality of life.

  15. Statistical Power in Evaluations That Investigate Effects on Multiple Outcomes: A Guide for Researchers

    Science.gov (United States)

    Porter, Kristin E.

    2016-01-01

    In education research and in many other fields, researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple…

  16. Multiple Levels of Suffering

    Science.gov (United States)

    Kiley, Kasey B.; Haywood, Carlton; Bediako, Shawn M.; Lanzkron, Sophie; Carroll, C. Patrick; Buenaver, Luis F.; Pejsa, Megan; Edwards, Robert R.; Haythornthwaite, Jennifer A.; Campbell, Claudia M.

    2016-01-01

    Objective: People living with sickle cell disease (SCD) experience severe episodic and chronic pain and frequently report poor interpersonal treatment within health-care settings. In this particularly relevant context, we examined the relationship between perceived discrimination and both clinical and laboratory pain. Methods: Seventy-one individuals with SCD provided self-reports of experiences with discrimination in health-care settings and clinical pain severity, and completed a psychophysical pain testing battery in the laboratory. Results: Discrimination in health-care settings was correlated with greater clinical pain severity and enhanced sensitivity to multiple laboratory-induced pain measures, as well as stress, depression, and sleep. After controlling for relevant covariates, discrimination remained a significant predictor of mechanical temporal summation (a marker of central pain facilitation), but not clinical pain severity or suprathreshold heat pain response. Furthermore, a significant interaction between experience with discrimination and clinical pain severity was associated with mechanical temporal summation; increased experience with discrimination was associated with an increased correlation between clinical pain severity and temporal summation of pain. Discussion: Perceived discrimination within health-care settings was associated with pain facilitation. These findings suggest that discrimination may be related to increased central sensitization among SCD patients, and more broadly that health-care social environments may interact with pain pathophysiology. PMID:26889615

  17. Accurate scaling on multiplicity

    International Nuclear Information System (INIS)

    Golokhvastov, A.I.

    1989-01-01

    The commonly used formula of KNO scaling P n =Ψ(n/ ) for descrete distributions (multiplicity distributions) is shown to contradict mathematically the condition ΣP n =1. The effect is essential even at ISR energies. A consistent generalization of the concept of similarity for multiplicity distributions is obtained. The multiplicity distributions of negative particles in PP and also e + e - inelastic interactions are similar over the whole studied energy range. Collider data are discussed. 14 refs.; 8 figs

  18. Robust multiple frequency multiple power localization schemes in the presence of multiple jamming attacks.

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulqader Hussein

    Full Text Available Localization of the wireless sensor network is a vital area acquiring an impressive research concern and called upon to expand more with the rising of its applications. As localization is gaining prominence in wireless sensor network, it is vulnerable to jamming attacks. Jamming attacks disrupt communication opportunity among the sender and receiver and deeply impact the localization process, leading to a huge error of the estimated sensor node position. Therefore, detection and elimination of jamming influence are absolutely indispensable. Range-based techniques especially Received Signal Strength (RSS is facing severe impact of these attacks. This paper proposes algorithms based on Combination Multiple Frequency Multiple Power Localization (C-MFMPL and Step Function Multiple Frequency Multiple Power Localization (SF-MFMPL. The algorithms have been tested in the presence of multiple types of jamming attacks including capture and replay, random and constant jammers over a log normal shadow fading propagation model. In order to overcome the impact of random and constant jammers, the proposed method uses two sets of frequencies shared by the implemented anchor nodes to obtain the averaged RSS readings all over the transmitted frequencies successfully. In addition, three stages of filters have been used to cope with the replayed beacons caused by the capture and replay jammers. In this paper the localization performance of the proposed algorithms for the ideal case which is defined by without the existence of the jamming attack are compared with the case of jamming attacks. The main contribution of this paper is to achieve robust localization performance in the presence of multiple jamming attacks under log normal shadow fading environment with a different simulation conditions and scenarios.

  19. ALICE Photon Multiplicity Detector

    CERN Multimedia

    Nayak, T

    2013-01-01

    Photon Multiplicity Detector (PMD) measures the multiplicity and spatial distribution of photons in the forward region of ALICE on a event-by-event basis. PMD is a pre-shower detector having fine granularity and full azimuthal coverage in the pseudo-rapidity region 2.3 < η < 3.9.

  20. Body Weight - Multiple Languages

    Science.gov (United States)

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Body Weight URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Body Weight - Multiple Languages To use the sharing features on this page, ...

  1. Multiplicity in difference geometry

    OpenAIRE

    Tomasic, Ivan

    2011-01-01

    We prove a first principle of preservation of multiplicity in difference geometry, paving the way for the development of a more general intersection theory. In particular, the fibres of a \\sigma-finite morphism between difference curves are all of the same size, when counted with correct multiplicities.

  2. Applying Multiple Intelligences

    Science.gov (United States)

    Christodoulou, Joanna A.

    2009-01-01

    The ideas of multiple intelligences introduced by Howard Gardner of Harvard University more than 25 years ago have taken form in many ways, both in schools and in other sometimes-surprising settings. The silver anniversary of Gardner's learning theory provides an opportunity to reflect on the ways multiple intelligences theory has taken form and…

  3. Formation of multiple networks

    DEFF Research Database (Denmark)

    Magnani, Matteo; Rossi, Luca

    2013-01-01

    we introduce the first network formation model for multiple networks. Network formation models are among the most popular tools in traditional network studies, because of both their practical and theoretical impact. However, existing models are not sufficient to describe the generation of multiple...

  4. Orchestrating Multiple Intelligences

    Science.gov (United States)

    Moran, Seana; Kornhaber, Mindy; Gardner, Howard

    2006-01-01

    Education policymakers often go astray when they attempt to integrate multiple intelligences theory into schools, according to the originator of the theory, Howard Gardner, and his colleagues. The greatest potential of a multiple intelligences approach to education grows from the concept of a profile of intelligences. Each learner's intelligence…

  5. Assessing Children's Multiplicative Thinking

    Science.gov (United States)

    Hurst, Chris; Hurrell, Derek

    2016-01-01

    Multiplicative thinking is a "big idea" of mathematics that underpins much of the mathematics learned beyond the early primary school years. This paper reports on a current study that utilises an interview tool and a written quiz to gather data about children's multiplicative thinking. The development of the tools and some of the…

  6. Parallelize Automated Tests in a Build and Test Environment

    OpenAIRE

    Durairaj, Selva Ganesh

    2016-01-01

    This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...

  7. Plume rise from multiple sources

    International Nuclear Information System (INIS)

    Briggs, G.A.

    1975-01-01

    A simple enhancement factor for plume rise from multiple sources is proposed and tested against plume-rise observations. For bent-over buoyant plumes, this results in the recommendation that multiple-source rise be calculated as [(N + S)/(1 + S)]/sup 1/3/ times the single-source rise, Δh 1 , where N is the number of sources and S = 6 (total width of source configuration/N/sup 1/3/ Δh 1 )/sup 3/2/. For calm conditions a crude but simple method is suggested for predicting the height of plume merger and subsequent behavior which is based on the geometry and velocity variations of a single buoyant plume. Finally, it is suggested that large clusters of buoyant sources might occasionally give rise to concentrated vortices either within the source configuration or just downwind of it

  8. Safe Dynamic Multiple Inheritance

    DEFF Research Database (Denmark)

    Ernst, Erik

    2002-01-01

    Multiple inheritance and similar mechanisms are usually only supported at compile time in statically typed languages. Nevertheless, dynamic multiple inheritance would be very useful in the development of complex systems, because it allows the creation of many related classes without an explosion...... in the size and level of redundancy in the source code. In fact, dynamic multiple inheritance is already available. The language gbeta is statically typed and has supported run-time combination of classes and methods since 1997, by means of the combination operator '&'. However, with certain combinations...

  9. A multiplicity logic unit

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Zagorski, A.

    1981-01-01

    The logic diagram principle of operation and some details of the design of the multiplicity logic unit are presented. This unit was specially designed to fulfil the requirements of a multidetector arrangement for gamma-ray multiplicity measurements. The unit is equipped with 16 inputs controlled by a common coincidence gate. It delivers a linear output pulse with the height proportional to the multiplicity of coincidences and logic pulses corresponding to 0, 1, ... up to >= 5-fold coincidences. These last outputs are used to steer the routing unit working with the multichannel analyser. (orig.)

  10. Fission neutron multiplicity calculations

    International Nuclear Information System (INIS)

    Maerten, H.; Ruben, A.; Seeliger, D.

    1991-01-01

    A model for calculating neutron multiplicities in nuclear fission is presented. It is based on the solution of the energy partition problem as function of mass asymmetry within a phenomenological approach including temperature-dependent microscopic energies. Nuclear structure effects on fragment de-excitation, which influence neutron multiplicities, are discussed. Temperature effects on microscopic energy play an important role in induced fission reactions. Calculated results are presented for various fission reactions induced by neutrons. Data cover the incident energy range 0-20 MeV, i.e. multiple chance fission is considered. (author). 28 refs, 13 figs

  11. The accuracy of prediction of genomic selection in elite hybrid rye populations surpasses the accuracy of marker-assisted selection and is equally augmented by multiple field evaluation locations and test years.

    Science.gov (United States)

    Wang, Yu; Mette, Michael Florian; Miedaner, Thomas; Gottwald, Marlen; Wilde, Peer; Reif, Jochen C; Zhao, Yusheng

    2014-07-04

    Marker-assisted selection (MAS) and genomic selection (GS) based on genome-wide marker data provide powerful tools to predict the genotypic value of selection material in plant breeding. However, case-to-case optimization of these approaches is required to achieve maximum accuracy of prediction with reasonable input. Based on extended field evaluation data for grain yield, plant height, starch content and total pentosan content of elite hybrid rye derived from testcrosses involving two bi-parental populations that were genotyped with 1048 molecular markers, we compared the accuracy of prediction of MAS and GS in a cross-validation approach. MAS delivered generally lower and in addition potentially over-estimated accuracies of prediction than GS by ridge regression best linear unbiased prediction (RR-BLUP). The grade of relatedness of the plant material included in the estimation and test sets clearly affected the accuracy of prediction of GS. Within each of the two bi-parental populations, accuracies differed depending on the relatedness of the respective parental lines. Across populations, accuracy increased when both populations contributed to estimation and test set. In contrast, accuracy of prediction based on an estimation set from one population to a test set from the other population was low despite that the two bi-parental segregating populations under scrutiny shared one parental line. Limiting the number of locations or years in field testing reduced the accuracy of prediction of GS equally, supporting the view that to establish robust GS calibration models a sufficient number of test locations is of similar importance as extended testing for more than one year. In hybrid rye, genomic selection is superior to marker-assisted selection. However, it achieves high accuracies of prediction only for selection candidates closely related to the plant material evaluated in field trials, resulting in a rather pessimistic prognosis for distantly related material

  12. Investigating the effect of child maltreatment on early adolescent peer-on-peer sexual aggression: testing a multiple mediator model in a non-incarcerated sample of Danish adolescents

    Directory of Open Access Journals (Sweden)

    Rikke Holm Bramsen

    2014-06-01

    Full Text Available Objective: The aim of the present study was to investigate the relationship between child maltreatment and severe early adolescent peer-on-peer sexual aggression, using a multiple mediator model. Methods: The study comprised 330 male Grade 9 students with a mean age of 14.9 years (SD=0.5. Results: Estimates from the mediation model indicated significant indirect effects of child physical abuse on sexual aggression via peer influence and insecure-hostile masculinity. No significant total effect of child sexual abuse and child neglect on sexual aggression was found. Conclusions: Findings of the present study identify risk factors that are potentially changeable and therefore of value in informing the design of prevention programs aiming at early adolescent peer-on-peer sexual aggression in at-risk youth.

  13. Investigating the effect of child maltreatment on early adolescent peer-on-peer sexual aggression: testing a multiple mediator model in a non-incarcerated sample of Danish adolescents.

    Science.gov (United States)

    Bramsen, Rikke Holm; Lasgaard, Mathias; Koss, Mary P; Elklit, Ask; Banner, Jytte

    2014-01-01

    The aim of the present study was to investigate the relationship between child maltreatment and severe early adolescent peer-on-peer sexual aggression, using a multiple mediator model. The study comprised 330 male Grade 9 students with a mean age of 14.9 years (SD=0.5). Estimates from the mediation model indicated significant indirect effects of child physical abuse on sexual aggression via peer influence and insecure-hostile masculinity. No significant total effect of child sexual abuse and child neglect on sexual aggression was found. Findings of the present study identify risk factors that are potentially changeable and therefore of value in informing the design of prevention programs aiming at early adolescent peer-on-peer sexual aggression in at-risk youth.

  14. Multiple sclerosis research

    International Nuclear Information System (INIS)

    Battaglia, M.A.

    1990-01-01

    This volume proceedings contains four contributions which are in INIS scope, dealing with MRI and SPECT in the diagnosis of multiple sclerosis and assessment of disease activity. (H.W.). refs.; figs.; tabs

  15. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.; Alkhalifah, Tariq Ali

    2014-01-01

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling

  16. Connecting the Production Multiple

    DEFF Research Database (Denmark)

    Lichen, Alex Yu; Mouritsen, Jan

    &OP process itself is a fluid object, but there is still possibility to organise the messy Production. There are connections between the Production multiple and the managerial technology fluid. The fluid enacted the multiplicity of Production thus making it more difficult to be organised because there were...... in opposite directions. They are all part of the fluid object. There is no single chain of circulating references that makes the object a matter of fact. Accounting fluidity means that references drift back and forth and enact new realities also connected to the chain. In this setting future research may......This paper is about objects. It follows post ANT trajectories and finds that objects are multiple and fluid. Extant classic ANT inspired accounting research largely sees accounting inscriptions as immutable mobiles. Although multiplicity of objects upon which accounting acts has been explored...

  17. Multiple sex partner

    African Journals Online (AJOL)

    User

    intercourse, about 60% reported having a single sexual partner and 40% reported having multiple ... masturbation, start having sex at a younger age, have sex with married people and/or .... sex were considered unacceptable by 89 vs.

  18. Multiple Stages 2

    DEFF Research Database (Denmark)

    Andreasen, John

    Multiple stages 2: theatrical futures, set design, community plays, cultural capitals, democracy & drama, WWII dramas, performance on adoption, promenade about emigration, qualities in political theatre, performance analysis, dramaturgical education, Toulmin Variations...

  19. Rehabilitation and multiple sclerosis

    DEFF Research Database (Denmark)

    Dalgas, Ulrik

    2011-01-01

    In a chronic and disabling disease like multiple sclerosis, rehabilitation becomes of major importance in the preservation of physical, psychological and social functioning. Approximately 80% of patients have multiple sclerosis for more than 35 years and most will develop disability at some point......, a paradigm shift is taking place and it is now increasingly acknowledged that exercise therapy is both safe and beneficial. Robot-assisted training is also attracting attention in multiple sclerosis rehabilitation. Several sophisticated commercial robots exist, but so far the number of scientific studies...... promising. This drug has been shown to improve walking ability in some patients with multiple sclerosis, associated with a reduction of patients' self-reported ambulatory disability. Rehabilitation strategies involving these different approaches, or combinations of them, may be of great use in improving...

  20. The MARVEL assembly for neutron multiplication

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; Mathew T. Kinlaw

    2013-10-01

    A new multiplying test assembly is under development at Idaho National Laboratory to support research, validation, evaluation, and learning. The item is comprised of three stacked, highly-enriched uranium (HEU) cylinders, each 11.4 cm in diameter and having a combined height of up to 11.7 cm. The combined mass of all three cylinders is 20.3 kg of HEU. Calculations for the bare configuration of the assembly indicate a multiplication level of >3.5 (keff=0.72). Reflected configurations of the assembly, using either polyethylene or tungsten, are possible and have the capability of raising the assembly's multiplication level to greater than 10. This paper describes simulations performed to assess the assembly's multiplication level under different conditions and describes the resources available at INL to support the use of these materials. We also describe some preliminary calculations and test activities using the assembly to study neutron multiplication.