WorldWideScience

Sample records for multiple comparison test

  1. Kruskal-Wallis Test in Multiple Comparisons

    OpenAIRE

    Parys, Dariusz

    2009-01-01

    In this paper we show that the Kruskal-Wallis test can be transform to quadratic form among the Mann-Whitney or Kendal τ au concordance measures between pairs of treatments. A multiple comparisons procedure based on patterns of transitive ordering among treatments is implement. We also consider the circularity and non-transitive effects. Statystyka testu Kruskala-Wallisa przedstawiona jest w postaci formy kwadratowej z użyciem statystyki Manna-Whitneya lub miar konkordacji τ au Kendalla. N...

  2. A SAS(®) macro implementation of a multiple comparison post hoc test for a Kruskal-Wallis analysis.

    Science.gov (United States)

    Elliott, Alan C; Hynan, Linda S

    2011-04-01

    The Kruskal-Wallis (KW) nonparametric analysis of variance is often used instead of a standard one-way ANOVA when data are from a suspected non-normal population. The KW omnibus procedure tests for some differences between groups, but provides no specific post hoc pair wise comparisons. This paper provides a SAS(®) macro implementation of a multiple comparison test based on significant Kruskal-Wallis results from the SAS NPAR1WAY procedure. The implementation is designed for up to 20 groups at a user-specified alpha significance level. A Monte-Carlo simulation compared this nonparametric procedure to commonly used parametric multiple comparison tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Nonparametric Analysis of Right Censored Data with Multiple Comparisons

    OpenAIRE

    Shih, Hwei-Weng

    1982-01-01

    This report demonstrates the use of a computer program written in FORTRAN for the Burroughs B6800 computer at Utah State University to perform Breslow's (1970) generalization of the Kruskal-Wallis test for right censored data. A pairwise multiple comparison procedure using Bonferroni's inequality is also introduced and demonstrated. Comparisons are also made with a parametric F test and the original Kruskal-Wallis test. Application of these techniques to two data sets indicate that there is l...

  4. A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies

    Science.gov (United States)

    McClung, R. C.; Chell, G. G.; Millwater, H. R.; Russell, D. A.; Millwater, H. R.

    1999-01-01

    Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semielliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT versus SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.

  5. General solutions to multiple testing problems. Translation of "Sonnemann, E. (1982). Allgemeine Lösungen multipler Test probleme. EDV in Medizin und Biologie 13(4), 120-128".

    Science.gov (United States)

    Sonnemann, Eckart

    2008-10-01

    The introduction of sequentially rejective multiple test procedures (Einot and Gabriel, 1975; Naik, 1975; Holm, 1977; Holm, 1979) has caused considerable progress in the theory of multiple comparisons. Emphasizing the closure of multiple tests we give a survey of the general theory and its recent results in applications. Some new applications are given including a discussion of the connection with the theory of confidence regions.

  6. Feedback enhances the positive effects and reduces the negative effects of multiple-choice testing.

    Science.gov (United States)

    Butler, Andrew C; Roediger, Henry L

    2008-04-01

    Multiple-choice tests are used frequently in higher education without much consideration of the impact this form of assessment has on learning. Multiple-choice testing enhances retention of the material tested (the testing effect); however, unlike other tests, multiple-choice can also be detrimental because it exposes students to misinformation in the form of lures. The selection of lures can lead students to acquire false knowledge (Roediger & Marsh, 2005). The present research investigated whether feedback could be used to boost the positive effects and reduce the negative effects of multiple-choice testing. Subjects studied passages and then received a multiple-choice test with immediate feedback, delayed feedback, or no feedback. In comparison with the no-feedback condition, both immediate and delayed feedback increased the proportion of correct responses and reduced the proportion of intrusions (i.e., lure responses from the initial multiple-choice test) on a delayed cued recall test. Educators should provide feedback when using multiple-choice tests.

  7. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  8. Comparison between three option, four option and five option multiple choice question tests for quality parameters: A randomized study.

    Science.gov (United States)

    Vegada, Bhavisha; Shukla, Apexa; Khilnani, Ajeetkumar; Charan, Jaykaran; Desai, Chetna

    2016-01-01

    Most of the academic teachers use four or five options per item of multiple choice question (MCQ) test as formative and summative assessment. Optimal number of options in MCQ item is a matter of considerable debate among academic teachers of various educational fields. There is a scarcity of the published literature regarding the optimum number of option in each item of MCQ in the field of medical education. To compare three options, four options, and five options MCQs test for the quality parameters - reliability, validity, item analysis, distracter analysis, and time analysis. Participants were 3 rd semester M.B.B.S. students. Students were divided randomly into three groups. Each group was given one set of MCQ test out of three options, four options, and five option randomly. Following the marking of the multiple choice tests, the participants' option selections were analyzed and comparisons were conducted of the mean marks, mean time, validity, reliability and facility value, discrimination index, point biserial value, distracter analysis of three different option formats. Students score more ( P = 0.000) and took less time ( P = 0.009) for the completion of three options as compared to four options and five options groups. Facility value was more ( P = 0.004) in three options group as compared to four and five options groups. There was no significant difference between three groups for the validity, reliability, and item discrimination. Nonfunctioning distracters were more in the four and five options group as compared to three option group. Assessment based on three option MCQs is can be preferred over four option and five option MCQs.

  9. Analysis of Multiple Choice Tests Designed by Faculty Members of Kermanshah University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    Reza Pourmirza Kalhori

    2013-12-01

    Full Text Available Dear Editor Multiple choice tests are the most common objective tests in medical education which are used to assess the ind-ividual knowledge, recall, recognition and problem solving abilities. One of the testing components is the post-test analysis. This component includes; first, qualitative analysis of the taxonomy of questions based on the Bloom’s educational objectives and percentage of the questions with no structural problems; and second, the quantitative analysis of the reliability (KR-20 and indices of difficulty and differentiation (1. This descriptive-analytical study was aimed to qualitatively and quan-titatively investigate the multiple-choice tests of the faculty members at Kermanshah University of Medical Sciences in 2009-2010. The sample size comprised of 156 tests. Data were analyzed by SPSS-16 software using t-test, chi-squared test, ANOVA and Tukey multiple comparison tests. The mean of reliability (KR-20, difficulty index, and discrimination index were 0.68 (± 0.31, 0.56 (± 0.15 and 0.21 (± 0.15, respectively, which were acceptable. The analysis of the tests at Mashad University of Medical Sciences indicated that the mean for the reliability of the tests was 0.72, and 52.2% of the tests had inappropriate difficulty index and 49.2% of the tests did not have acceptable differentiation index (2. Comparison of the tests at Kermanshah University of Medical Sciences for the fields of anatomy, physiology, biochemistry, genetics, statistics and behavioral sciences courses at Malaysia Faculty of Medicine (3 and tests at Argentina Faculty of Medicine (4 showed that while difficulty index was acceptable in all three universities, but differentiation indices in Malaysia and Argentina Medical Faculties were higher than that in Kermanshah University of Medical Sciences. The mean for the questions with no structural flaws in all tests, taxonomy I, taxonomy II, and taxonomy III were 73.88% (± 14.88, 34.65% (± 15.78, 41.34% (± 13

  10. Multiple Improvements of Multiple Imputation Likelihood Ratio Tests

    OpenAIRE

    Chan, Kin Wai; Meng, Xiao-Li

    2017-01-01

    Multiple imputation (MI) inference handles missing data by first properly imputing the missing values $m$ times, and then combining the $m$ analysis results from applying a complete-data procedure to each of the completed datasets. However, the existing method for combining likelihood ratio tests has multiple defects: (i) the combined test statistic can be negative in practice when the reference null distribution is a standard $F$ distribution; (ii) it is not invariant to re-parametrization; ...

  11. Characterizing the Joint Effect of Diverse Test-Statistic Correlation Structures and Effect Size on False Discovery Rates in a Multiple-Comparison Study of Many Outcome Measures

    Science.gov (United States)

    Feiveson, Alan H.; Ploutz-Snyder, Robert; Fiedler, James

    2011-01-01

    In their 2009 Annals of Statistics paper, Gavrilov, Benjamini, and Sarkar report the results of a simulation assessing the robustness of their adaptive step-down procedure (GBS) for controlling the false discovery rate (FDR) when normally distributed test statistics are serially correlated. In this study we extend the investigation to the case of multiple comparisons involving correlated non-central t-statistics, in particular when several treatments or time periods are being compared to a control in a repeated-measures design with many dependent outcome measures. In addition, we consider several dependence structures other than serial correlation and illustrate how the FDR depends on the interaction between effect size and the type of correlation structure as indexed by Foerstner s distance metric from an identity. The relationship between the correlation matrix R of the original dependent variables and R, the correlation matrix of associated t-statistics is also studied. In general R depends not only on R, but also on sample size and the signed effect sizes for the multiple comparisons.

  12. Multiple Choice Testing and the Retrieval Hypothesis of the Testing Effect

    Science.gov (United States)

    Sensenig, Amanda E.

    2010-01-01

    Taking a test often leads to enhanced later memory for the tested information, a phenomenon known as the "testing effect". This memory advantage has been reliably demonstrated with recall tests but not multiple choice tests. One potential explanation for this finding is that multiple choice tests do not rely on retrieval processes to the same…

  13. Advances in ranking and selection, multiple comparisons, and reliability methodology and applications

    CERN Document Server

    Balakrishnan, N; Nagaraja, HN

    2007-01-01

    S. Panchapakesan has made significant contributions to ranking and selection and has published in many other areas of statistics, including order statistics, reliability theory, stochastic inequalities, and inference. Written in his honor, the twenty invited articles in this volume reflect recent advances in these areas and form a tribute to Panchapakesan's influence and impact on these areas. Thematically organized, the chapters cover a broad range of topics from: Inference; Ranking and Selection; Multiple Comparisons and Tests; Agreement Assessment; Reliability; and Biostatistics. Featuring

  14. Reproducibility of R-fMRI metrics on the impact of different strategies for multiple comparison correction and sample sizes.

    Science.gov (United States)

    Chen, Xiao; Lu, Bin; Yan, Chao-Gan

    2018-01-01

    Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. The positive and negative consequences of multiple-choice testing.

    Science.gov (United States)

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  16. A Fiducial Approach to Extremes and Multiple Comparisons

    Science.gov (United States)

    Wandler, Damian V.

    2010-01-01

    Generalized fiducial inference is a powerful tool for many difficult problems. Based on an extension of R. A. Fisher's work, we used generalized fiducial inference for two extreme value problems and a multiple comparison procedure. The first extreme value problem is dealing with the generalized Pareto distribution. The generalized Pareto…

  17. Optimizing multiple-choice tests as tools for learning.

    Science.gov (United States)

    Little, Jeri L; Bjork, Elizabeth Ligon

    2015-01-01

    Answering multiple-choice questions with competitive alternatives can enhance performance on a later test, not only on questions about the information previously tested, but also on questions about related information not previously tested-in particular, on questions about information pertaining to the previously incorrect alternatives. In the present research, we assessed a possible explanation for this pattern: When multiple-choice questions contain competitive incorrect alternatives, test-takers are led to retrieve previously studied information pertaining to all of the alternatives in order to discriminate among them and select an answer, with such processing strengthening later access to information associated with both the correct and incorrect alternatives. Supporting this hypothesis, we found enhanced performance on a later cued-recall test for previously nontested questions when their answers had previously appeared as competitive incorrect alternatives in the initial multiple-choice test, but not when they had previously appeared as noncompetitive alternatives. Importantly, however, competitive alternatives were not more likely than noncompetitive alternatives to be intruded as incorrect responses, indicating that a general increased accessibility for previously presented incorrect alternatives could not be the explanation for these results. The present findings, replicated across two experiments (one in which corrective feedback was provided during the initial multiple-choice testing, and one in which it was not), thus strongly suggest that competitive multiple-choice questions can trigger beneficial retrieval processes for both tested and related information, and the results have implications for the effective use of multiple-choice tests as tools for learning.

  18. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  19. The Multiple Tasks Test: development and normal strategies.

    NARCIS (Netherlands)

    Bloem, B.R.; Valkenburg, V.V.; Slabbekoorn, M.; Willemsen, M.D.

    2001-01-01

    Simultaneous challenge of posture and cognition ("dual tasks") may predict falls better than tests of isolated components of postural control. We describe a new balance test (the Multiple Tasks Test, MTT) which (1) is based upon simultaneous assessment of multiple (>2) postural components; (2)

  20. A Review of Multiple Hypothesis Testing in Otolaryngology Literature

    Science.gov (United States)

    Kirkham, Erin M.; Weaver, Edward M.

    2018-01-01

    Objective Multiple hypothesis testing (or multiple testing) refers to testing more than one hypothesis within a single analysis, and can inflate the Type I error rate (false positives) within a study. The aim of this review was to quantify multiple testing in recent large clinical studies in the otolaryngology literature and to discuss strategies to address this potential problem. Data sources Original clinical research articles with >100 subjects published in 2012 in the four general otolaryngology journals with the highest Journal Citation Reports 5-year impact factors. Review methods Articles were reviewed to determine whether the authors tested greater than five hypotheses in at least one family of inferences. For the articles meeting this criterion for multiple testing, Type I error rates were calculated and statistical correction was applied to the reported results. Results Of the 195 original clinical research articles reviewed, 72% met the criterion for multiple testing. Within these studies, there was a mean 41% chance of a Type I error and, on average, 18% of significant results were likely to be false positives. After the Bonferroni correction was applied, only 57% of significant results reported within the articles remained significant. Conclusion Multiple testing is common in recent large clinical studies in otolaryngology and deserves closer attention from researchers, reviewers and editors. Strategies for adjusting for multiple testing are discussed. PMID:25111574

  1. Common pitfalls in statistical analysis: The perils of multiple testing

    Science.gov (United States)

    Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc

    2016-01-01

    Multiple testing refers to situations where a dataset is subjected to statistical testing multiple times - either at multiple time-points or through multiple subgroups or for multiple end-points. This amplifies the probability of a false-positive finding. In this article, we look at the consequences of multiple testing and explore various methods to deal with this issue. PMID:27141478

  2. Comparison of physical fitness tests in swimming

    OpenAIRE

    Dostálová, Sabina

    2015-01-01

    Title: Comparison of physical fitness tests in swimming. Objective: The aim of this thesis is to evaluate specific tests, used while testing selected physical abilities in swimming. By specific tests we mean tests realized in the water. Selected tests are intended for swim coaches, who train junior to senior age groups. Methods: The chosen method was a comparison of studies, that pursue selected specific tests. We created partial conclusions for every test by summing up the results of differe...

  3. Testing multiple statistical hypotheses resulted in spurious associations: a study of astrological signs and health.

    Science.gov (United States)

    Austin, Peter C; Mamdani, Muhammad M; Juurlink, David N; Hux, Janet E

    2006-09-01

    To illustrate how multiple hypotheses testing can produce associations with no clinical plausibility. We conducted a study of all 10,674,945 residents of Ontario aged between 18 and 100 years in 2000. Residents were randomly assigned to equally sized derivation and validation cohorts and classified according to their astrological sign. Using the derivation cohort, we searched through 223 of the most common diagnoses for hospitalization until we identified two for which subjects born under one astrological sign had a significantly higher probability of hospitalization compared to subjects born under the remaining signs combined (P<0.05). We tested these 24 associations in the independent validation cohort. Residents born under Leo had a higher probability of gastrointestinal hemorrhage (P=0.0447), while Sagittarians had a higher probability of humerus fracture (P=0.0123) compared to all other signs combined. After adjusting the significance level to account for multiple comparisons, none of the identified associations remained significant in either the derivation or validation cohort. Our analyses illustrate how the testing of multiple, non-prespecified hypotheses increases the likelihood of detecting implausible associations. Our findings have important implications for the analysis and interpretation of clinical studies.

  4. Optimizing Multiple-Choice Tests as Learning Events

    Science.gov (United States)

    Little, Jeri Lynn

    2011-01-01

    Although generally used for assessment, tests can also serve as tools for learning--but different test formats may not be equally beneficial. Specifically, research has shown multiple-choice tests to be less effective than cued-recall tests in improving the later retention of the tested information (e.g., see meta-analysis by Hamaker, 1986),…

  5. Response of HDR-VKL piping system to seismic test excitations: Comparison of analytical predictions and test measurements

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1989-01-01

    As part of the earthquake investigations at the HDR (Heissdampfreaktor) Test Facility in Kahl/Main, FRG, simulated seismic tests (SHAM) were performed during April--May 1988 on the VKL (Versuchskreislauf) piping system. The purpose of these experiments was to study the behavior of piping subjected to a range of seismic excitation levels including those that exceed design levels manifold and that might induce failure of pipe supports or plasticity in the pipe runs, and to establish seismic margins for piping and pipe supports. Data obtained in the tests are also used to validate analysis methods. Detailed reports on the SHAM experiments are given elsewhere. The objective of this document is to evaluate a subsystem analysis module of the SMACS code. This module is a linear finite-element based program capable of calculating the response of nuclear power plant subsystems subjected to independent multiple-acceleration input excitation. The evaluation is based on a comparison of computational results of simulation of SHAM tests with corresponding test measurements

  6. Testing Group Mean Differences of Latent Variables in Multilevel Data Using Multiple-Group Multilevel CFA and Multilevel MIMIC Modeling.

    Science.gov (United States)

    Kim, Eun Sook; Cao, Chunhua

    2015-01-01

    Considering that group comparisons are common in social science, we examined two latent group mean testing methods when groups of interest were either at the between or within level of multilevel data: multiple-group multilevel confirmatory factor analysis (MG ML CFA) and multilevel multiple-indicators multiple-causes modeling (ML MIMIC). The performance of these methods were investigated through three Monte Carlo studies. In Studies 1 and 2, either factor variances or residual variances were manipulated to be heterogeneous between groups. In Study 3, which focused on within-level multiple-group analysis, six different model specifications were considered depending on how to model the intra-class group correlation (i.e., correlation between random effect factors for groups within cluster). The results of simulations generally supported the adequacy of MG ML CFA and ML MIMIC for multiple-group analysis with multilevel data. The two methods did not show any notable difference in the latent group mean testing across three studies. Finally, a demonstration with real data and guidelines in selecting an appropriate approach to multilevel multiple-group analysis are provided.

  7. Testing for Nonuniform Differential Item Functioning with Multiple Indicator Multiple Cause Models

    Science.gov (United States)

    Woods, Carol M.; Grimm, Kevin J.

    2011-01-01

    In extant literature, multiple indicator multiple cause (MIMIC) models have been presented for identifying items that display uniform differential item functioning (DIF) only, not nonuniform DIF. This article addresses, for apparently the first time, the use of MIMIC models for testing both uniform and nonuniform DIF with categorical indicators. A…

  8. M-GCAT: interactively and efficiently constructing large-scale multiple genome comparison frameworks in closely related species

    Directory of Open Access Journals (Sweden)

    Messeguer Xavier

    2006-10-01

    Full Text Available Abstract Background Due to recent advances in whole genome shotgun sequencing and assembly technologies, the financial cost of decoding an organism's DNA has been drastically reduced, resulting in a recent explosion of genomic sequencing projects. This increase in related genomic data will allow for in depth studies of evolution in closely related species through multiple whole genome comparisons. Results To facilitate such comparisons, we present an interactive multiple genome comparison and alignment tool, M-GCAT, that can efficiently construct multiple genome comparison frameworks in closely related species. M-GCAT is able to compare and identify highly conserved regions in up to 20 closely related bacterial species in minutes on a standard computer, and as many as 90 (containing 75 cloned genomes from a set of 15 published enterobacterial genomes in an hour. M-GCAT also incorporates a novel comparative genomics data visualization interface allowing the user to globally and locally examine and inspect the conserved regions and gene annotations. Conclusion M-GCAT is an interactive comparative genomics tool well suited for quickly generating multiple genome comparisons frameworks and alignments among closely related species. M-GCAT is freely available for download for academic and non-commercial use at: http://alggen.lsi.upc.es/recerca/align/mgcat/intro-mgcat.html.

  9. Bees Algorithm for Construction of Multiple Test Forms in E-Testing

    Science.gov (United States)

    Songmuang, Pokpong; Ueno, Maomi

    2011-01-01

    The purpose of this research is to automatically construct multiple equivalent test forms that have equivalent qualities indicated by test information functions based on item response theory. There has been a trade-off in previous studies between the computational costs and the equivalent qualities of test forms. To alleviate this problem, we…

  10. International Semiotics: Item Difficulty and the Complexity of Science Item Illustrations in the PISA-2009 International Test Comparison

    Science.gov (United States)

    Solano-Flores, Guillermo; Wang, Chao; Shade, Chelsey

    2016-01-01

    We examined multimodality (the representation of information in multiple semiotic modes) in the context of international test comparisons. Using Program of International Student Assessment (PISA)-2009 data, we examined the correlation of the difficulty of science items and the complexity of their illustrations. We observed statistically…

  11. A test for the parameters of multiple linear regression models ...

    African Journals Online (AJOL)

    A test for the parameters of multiple linear regression models is developed for conducting tests simultaneously on all the parameters of multiple linear regression models. The test is robust relative to the assumptions of homogeneity of variances and absence of serial correlation of the classical F-test. Under certain null and ...

  12. An Application of Graphical Approach to Construct Multiple Testing Procedure in a Hypothetical Phase III Design

    Directory of Open Access Journals (Sweden)

    Naitee eTing

    2014-01-01

    Full Text Available Many multiple testing procedures (MTP have been developed in recent years. Among these new procedures, the graphical approach is flexible and easy to communicate with non-statisticians. A hypothetical Phase III clinical trial design is introduced in this manuscript to demonstrate how graphical approach can be applied in clinical product development. In this design, an active comparator is used. It is thought that this test drug under development could potentially be superior to this comparator. For comparison of efficacy, the primary endpoint is well established and widely accepted by regulatory agencies. However, an important secondary endpoint based on Phase II findings looks very promising. The target dose may have a good opportunity to deliver superiority to the comparator. Furthermore, a lower dose is included in case the target dose may demonstrate potential safety concerns. This Phase III study is designed as a non-inferiority trial with two doses, and two endpoints. This manuscript will illustrate how graphical approach is applied to this design in handling multiple testing issues.

  13. History and sensitivity comparison of the Spirodela polyrhiza microbiotest and Lemna toxicity tests

    Directory of Open Access Journals (Sweden)

    Baudo R.

    2015-01-01

    Full Text Available The history of toxicity tests with duckweeds shows that these assays with free-floating aquatic angiosperms are gaining increasing attention in ecotoxicological research and applications. Standard tests have been published by national and international organizations, mainly with the test species Lemna minor and Lemna gibba. Besides the former two test species the great duckweed Spirodela polyrhiza is to date also regularly used in duckweed testing. Under unfavorable environmental conditions, the latter species produces dormant stages (turions and this has triggered the attention of two research groups from Belgium and Greece to jointly develop a “stock culture independent” microbiotest with S. polyrhiza. A 72 h new test has been worked out which besides its independence of stock culturing and maintenance of live stocks is very simple and practical to perform, and much less demanding in space and time than the conventional duckweed tests. Extensive International Interlaboratory Comparisons on the S. polyrhiza microbiotest showed its robustness and reliability and triggered the decision to propose this new assay to the ISO for endorsement and publication as a standard toxicity test for duckweeds. Sensitivity comparison of the 72 h S. polyrhiza microbiotest with the 7d L. minor assay for 22 compounds belonging to different groups of chemicals revealed that based on growth as the effect criterion both duckweed assays have a similar sensitivity. Taking into account its multiple advantages and assets, the S. polyrhiza microbiotest is a reliable and attractive alternative to the conventional duckweed tests.

  14. Using automatic item generation to create multiple-choice test items.

    Science.gov (United States)

    Gierl, Mark J; Lai, Hollis; Turner, Simon R

    2012-08-01

    Many tests of medical knowledge, from the undergraduate level to the level of certification and licensure, contain multiple-choice items. Although these are efficient in measuring examinees' knowledge and skills across diverse content areas, multiple-choice items are time-consuming and expensive to create. Changes in student assessment brought about by new forms of computer-based testing have created the demand for large numbers of multiple-choice items. Our current approaches to item development cannot meet this demand. We present a methodology for developing multiple-choice items based on automatic item generation (AIG) concepts and procedures. We describe a three-stage approach to AIG and we illustrate this approach by generating multiple-choice items for a medical licensure test in the content area of surgery. To generate multiple-choice items, our method requires a three-stage process. Firstly, a cognitive model is created by content specialists. Secondly, item models are developed using the content from the cognitive model. Thirdly, items are generated from the item models using computer software. Using this methodology, we generated 1248 multiple-choice items from one item model. Automatic item generation is a process that involves using models to generate items using computer technology. With our method, content specialists identify and structure the content for the test items, and computer technology systematically combines the content to generate new test items. By combining these outcomes, items can be generated automatically. © Blackwell Publishing Ltd 2012.

  15. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  16. Comparison of Force and Moment Coefficients for the Same Test Article in Multiple Wind Tunnels

    Science.gov (United States)

    Deloach, Richard

    2013-01-01

    This paper compares the results of force and moment measurements made on the same test article and with the same balance in three transonic wind tunnels. Comparisons are made for the same combination of Reynolds number, Mach number, sideslip angle, control surface configuration, and angle of attack range. Between-tunnel force and moment differences are quantified. An analysis of variance was performed at four unique sites in the design space to assess the statistical significance of between-tunnel variation and any interaction with angle of attack. Tunnel to tunnel differences too large to attribute to random error were detected were observed for all forces and moments. In some cases these differences were independent of angle of attack and in other cases they changed with angle of attack.

  17. Comparison of the Clock Test and a questionnaire-based test for ...

    African Journals Online (AJOL)

    Comparison of the Clock Test and a questionnaire-based test for screening for cognitive impairment in Nigerians. D J VanderJagt, S Ganga, M O Obadofin, P Stanley, M Zimmerman, B J Skipper, R H Glew ...

  18. Multiple sclerosis: Left advantage for auditory laterality in dichotic tests of central auditory processing and relationship of psychoacoustic tests with the Multiple Sclerosis Disability Scale-EDSS.

    Science.gov (United States)

    Peñaloza López, Yolanda Rebeca; Orozco Peña, Xóchitl Daisy; Pérez Ruiz, Santiago Jesús

    2018-04-03

    To evaluate the central auditory processing disorders in patients with multiple sclerosis, emphasizing auditory laterality by applying psychoacoustic tests and to identify their relationship with the Multiple Sclerosis Disability Scale (EDSS) functions. Depression scales (HADS), EDSS, and 9 psychoacoustic tests to study CAPD were applied to 26 individuals with multiple sclerosis and 26 controls. Correlation tests were performed between the EDSS and psychoacoustic tests. Seven out of 9 psychoacoustic tests were significantly different (P<.05); right or left (14/19 explorations) with respect to control. In dichotic digits there was a left-ear advantage compared to the usual predominance of RDD. There was significant correlation in five psychoacoustic tests and the specific functions of EDSS. The left-ear advantage detected and interpreted as an expression of deficient influences of the corpus callosum and attention in multiple sclerosis should be investigated. There was a correlation between psychoacoustic tests and specific EDSS functions. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Accelerated spike resampling for accurate multiple testing controls.

    Science.gov (United States)

    Harrison, Matthew T

    2013-02-01

    Controlling for multiple hypothesis tests using standard spike resampling techniques often requires prohibitive amounts of computation. Importance sampling techniques can be used to accelerate the computation. The general theory is presented, along with specific examples for testing differences across conditions using permutation tests and for testing pairwise synchrony and precise lagged-correlation between many simultaneously recorded spike trains using interval jitter.

  20. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    Science.gov (United States)

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  1. Multiple Intelligences Profiles of Children with Attention Deficit and Hyperactivity Disorder in Comparison with Nonattention Deficit and Hyperactivity Disorder.

    Science.gov (United States)

    Najafi, Mostafa; Akouchekian, Shahla; Ghaderi, Alireza; Mahaki, Behzad; Rezaei, Mariam

    2017-01-01

    Attention deficit and hyperactivity disorder (ADHD) is a common psychological problem during childhood. This study aimed to evaluate multiple intelligences profiles of children with ADHD in comparison with non-ADHD. This cross-sectional descriptive analytical study was done on 50 children of 6-13 years old in two groups of with and without ADHD. Children with ADHD were referred to Clinics of Child and Adolescent Psychiatry, Isfahan University of Medical Sciences, in 2014. Samples were selected based on clinical interview (based on Diagnostic and Statistical Manual of Mental Disorders IV and parent-teacher strengths and difficulties questionnaire), which was done by psychiatrist and psychologist. Raven intelligence quotient (IQ) test was used, and the findings were compared to the results of multiple intelligences test. Data analysis was done using a multivariate analysis of covariance using SPSS20 software. Comparing the profiles of multiple intelligence among two groups, there are more kinds of multiple intelligences in control group than ADHD group, a difference which has been more significant in logical, interpersonal, and intrapersonal intelligence ( P multiple intelligences in two groups ( P > 0.05). The IQ average score in the control group and ADHD group was 102.42 ± 16.26 and 96.72 ± 16.06, respectively, that reveals the negative effect of ADHD on IQ average value. There was an insignificance relationship between linguistic and naturalist intelligence ( P > 0.05). However, in other kinds of multiple intelligences, direct and significant relationships were observed ( P < 0.05). Since the levels of IQ (Raven test) and MI in control group were more significant than ADHD group, ADHD is likely to be associated with logical-mathematical, interpersonal, and intrapersonal profiles.

  2. Comparison of multiple crystal structures with NMR data for engrailed homeodomain

    Energy Technology Data Exchange (ETDEWEB)

    Religa, Tomasz L. [MRC Centre for Protein Engineering (United Kingdom)], E-mail: tlr25@mrc-lmb.cam.ac.uk

    2008-03-15

    Two methods are currently available to solve high resolution protein structures-X-ray crystallography and nuclear magnetic resonance (NMR). Both methods usually produce highly similar structures, but small differences between both solutions are always observed. Here the raw NMR data as well as the solved NMR structure were compared to the multiple crystal structures solved for the WT 60 residue three helix bundle engrailed homeodomain (EnHD) and single point mutants. There was excellent agreement between TALOS-predicted and crystal structure-observed dihedral angles and a good agreement for the {sup 3}J(H{sup N}H{sup {alpha}}) couplings for the multiple crystal structures. Around 1% of NOEs were violated for any crystal structure, but no NOE was inconsistent with all of the crystal structures. Violations usually occurred for surface residues or for residues for which multiple discreet conformations were observed between the crystal structures. Comparison of the disorder shown in the multiple crystal structures shows little correlation with dynamics under native conditions for this protein.

  3. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    Directory of Open Access Journals (Sweden)

    Zongyue Yu

    2014-01-01

    Full Text Available A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testing plan including both the high temperatures and low temperatures is designed, and a statistical analysis method is developed. The reliability function of the product with multiple failure modes under variable working conditions is given by the proposed statistical analysis method. Finally, a numerical example is studied to illustrate the proposed accelerated testing. The results show that the proposed accelerated testing is rather efficient.

  4. Multiple Sources of Test Bias on the WISC-R and Bender-Gestalt Test.

    Science.gov (United States)

    Oakland, Thomas; Feigenbaum, David

    1979-01-01

    Assessed test bias on the Wechsler Intelligence Test for Children-Revised (WISC-R) and Bender-Gestalt. On the Bender, evidence of bias was infrequent and irregular. On the WISC-R, group differences were most discernible for age, sex, family structure, and race. Consistent patterns of bias were not apparent among comparison groups. (Author)

  5. Comparison of different cryogenic control strategies via simulation applied to a superconducting magnet test bench at CERN

    Science.gov (United States)

    Arpaia, P.; Coppier, H.; De Paola, D.; di Bernardo, M.; Guarino, A.; Pedemonte, B. Luz; Pezzetti, M.

    2017-12-01

    Industrial process controllers for cryogenic systems used in test facilities for superconducting magnets are typically PIDs, tuned by operational expertise according to users’ requirements (covering cryogenic transients and associated thermo-mechanical constraints). In this paper, an alternative fully-automatic solution, equally based on PID controllers, is proposed. Following the comparison of the operational expertise and alternative fully-automatic approaches, a new process control configuration, based on an estimated multiple-input/multiple-output (MIMO) model is proposed. The new MIMO model-based approach fulfils the required operational constraints while improving performance compared to existing solutions. The analysis and design work is carried out using both theoretical and numerical tools and is validated on the case study of the High Field Magnet (HFM) cryogenic test bench running at the SM18 test facility located at CERN. The proposed solution have been validated by simulation using the CERN ECOSIMPRO software tools using the cryogenic library (CRYOLIB [1]) developed at CERN.

  6. The comparison between science virtual and paper based test in measuring grade 7 students’ critical thinking

    Science.gov (United States)

    Dhitareka, P. H.; Firman, H.; Rusyati, L.

    2018-05-01

    This research is comparing science virtual and paper-based test in measuring grade 7 students’ critical thinking based on Multiple Intelligences and gender. Quasi experimental method with within-subjects design is conducted in this research in order to obtain the data. The population of this research was all seventh grade students in ten classes of one public secondary school in Bandung. There were 71 students within two classes taken randomly became the sample in this research. The data are obtained through 28 questions with a topic of living things and environmental sustainability constructed based on eight critical thinking elements proposed by Inch then the questions provided in science virtual and paper-based test. The data was analysed by using paired-samples t test when the data are parametric and Wilcoxon signed ranks test when the data are non-parametric. In general comparison, the p-value of the comparison between science virtual and paper-based tests’ score is 0.506, indicated that there are no significance difference between science virtual and paper-based test based on the tests’ score. The results are furthermore supported by the students’ attitude result which is 3.15 from the scale from 1 to 4, indicated that they have positive attitudes towards Science Virtual Test.

  7. The Contribution of Numerical Magnitude Comparison and Phonological Processing to Individual Differences in Fourth Graders' Multiplication Fact Ability.

    Directory of Open Access Journals (Sweden)

    Tamara M J Schleepen

    Full Text Available Although numerical magnitude processing has been related to individual differences in arithmetic, its role in children's multiplication performance remains largely unknown. On the other hand, studies have indicated that phonological awareness is an important correlate of individual differences in children's multiplication performance, but the involvement of phonological memory, another important phonological processing skill, has not been studied in much detail. Furthermore, knowledge about the relative contribution of above mentioned processes to the specific arithmetic operation of multiplication in children is lacking. The present study therefore investigated for the first time the unique contributions of numerical magnitude comparison and phonological processing in explaining individual differences in 63 fourth graders' multiplication fact ability (mean age = 9.6 years, SD = .67. The results showed that children's multiplication fact competency correlated significantly with symbolic and nonsymbolic magnitude comparison as well as with phonological short-term memory. A hierarchical regression analysis revealed that, after controlling for intellectual ability and general reaction time, both symbolic and nonsymbolic magnitude comparison and phonological short-term memory accounted for unique variance in multiplication fact performance. The ability to compare symbolic magnitudes was found to contribute the most, indicating that the access to numerical magnitudes by means of Arabic digits is a key factor in explaining individual differences in children's multiplication fact ability.

  8. Comparison of reconfigurable structures for flexible word-length multiplication

    Directory of Open Access Journals (Sweden)

    O. A. Pfänder

    2008-05-01

    Full Text Available Binary multiplication continues to be one of the essential arithmetic operations in digital circuits. Even though field-programmable gate arrays (FPGAs are becoming more and more powerful these days, the vendors cannot avoid implementing multiplications with high word-lengths using embedded blocks instead of configurable logic. But on the other hand, the circuit's efficiency decreases if the provided word-length of the hard-wired multipliers exceeds the precision requirements of the algorithm mapped into the FPGA. Thus it is beneficial to use multiplier blocks with configurable word-length, optimized for area, speed and power dissipation, e.g. regarding digital signal processing (DSP applications.

    In this contribution, we present different approaches and structures for the realization of a multiplication with variable precision and perform an objective comparison. This includes one approach based on a modified Baugh and Wooley algorithm and three structures using Booth's arithmetic operand recoding with different array structures. All modules have the option to compute signed two's complement fix-point numbers either as an individual computing unit or interconnected to a superior array. Therefore, a high throughput at low precision through parallelism, or a high precision through concatenation can be achieved.

  9. Dtest Testing Software

    Science.gov (United States)

    Jain, Abhinandan; Cameron, Jonathan M.; Myint, Steven

    2013-01-01

    This software runs a suite of arbitrary software tests spanning various software languages and types of tests (unit level, system level, or file comparison tests). The dtest utility can be set to automate periodic testing of large suites of software, as well as running individual tests. It supports distributing multiple tests over multiple CPU cores, if available. The dtest tool is a utility program (written in Python) that scans through a directory (and its subdirectories) and finds all directories that match a certain pattern and then executes any tests in that directory as described in simple configuration files.

  10. A comparison of conventional mechanical testing techniques with innovative testing techniques for the evaluation of mechanical properties of NPP structural materials

    International Nuclear Information System (INIS)

    Liddell, P.A.; Kopriva, R.

    2015-01-01

    The innovative testing methods of Small Punch (SP) and Automated Ball Indentation (ABI) tests are based on the determination of material properties from sub-sized samples. These methods are promising to evaluate the components of nuclear power plants since they preserve the structural integrity of the component. The SP test is a semi-destructive method that employs miniaturised plate-shaped samples of various geometries. The method is based on the penetration of a sample with a semi-spherical punch. The sample deflection is measured throughout the test. The ABI test is a fully automatic test based on multiple indentations at a single penetration location on a polished sample surface with a spherical indenter of various diameters. The purpose of the test is to determine the tensile properties of materials in a non-destructive and localised fashion. A comparison has been made between SP, ABI and conventional tensile tests on the measurement of yield strength for the A533B (JRQ) ferritic steel which is a base metal of the pressure vessels of western PWR. The results show an excellent correlation for both innovative methods and the conventional tensile tests

  11. All of the above: When multiple correct response options enhance the testing effect.

    Science.gov (United States)

    Bishara, Anthony J; Lanzo, Lauren A

    2015-01-01

    Previous research has shown that multiple choice tests often improve memory retention. However, the presence of incorrect lures often attenuates this memory benefit. The current research examined the effects of "all of the above" (AOTA) options. When such options are correct, no incorrect lures are present. In the first three experiments, a correct AOTA option on an initial test led to a larger memory benefit than no test and standard multiple choice test conditions. The benefits of a correct AOTA option occurred even without feedback on the initial test; for both 5-minute and 48-hour retention delays; and for both cued recall and multiple choice final test formats. In the final experiment, an AOTA question led to better memory retention than did a control condition that had identical timing and exposure to response options. However, the benefits relative to this control condition were similar regardless of the type of multiple choice test (AOTA or not). Results suggest that retrieval contributes to multiple choice testing effects. However, the extra testing effect from a correct AOTA option, rather than being due to more retrieval, might be due simply to more exposure to correct information.

  12. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  13. Multiple Intelligences Profiles of Children with Attention Deficit and Hyperactivity Disorder in Comparison with Nonattention Deficit and Hyperactivity Disorder

    Directory of Open Access Journals (Sweden)

    Mostafa Najafi

    2017-01-01

    Full Text Available Background: Attention deficit and hyperactivity disorder (ADHD is a common psychological problem during childhood. This study aimed to evaluate multiple intelligences profiles of children with ADHD in comparison with non-ADHD. Materials and Methods: This cross-sectional descriptive analytical study was done on 50 children of 6–13 years old in two groups of with and without ADHD. Children with ADHD were referred to Clinics of Child and Adolescent Psychiatry, Isfahan University of Medical Sciences, in 2014. Samples were selected based on clinical interview (based on Diagnostic and Statistical Manual of Mental Disorders IV and parent–teacher strengths and difficulties questionnaire, which was done by psychiatrist and psychologist. Raven intelligence quotient (IQ test was used, and the findings were compared to the results of multiple intelligences test. Data analysis was done using a multivariate analysis of covariance using SPSS20 software. Results: Comparing the profiles of multiple intelligence among two groups, there are more kinds of multiple intelligences in control group than ADHD group, a difference which has been more significant in logical, interpersonal, and intrapersonal intelligence (P 0.05. The IQ average score in the control group and ADHD group was 102.42 ± 16.26 and 96.72 ± 16.06, respectively, that reveals the negative effect of ADHD on IQ average value. There was an insignificance relationship between linguistic and naturalist intelligence (P > 0.05. However, in other kinds of multiple intelligences, direct and significant relationships were observed (P < 0.05. Conclusions: Since the levels of IQ (Raven test and MI in control group were more significant than ADHD group, ADHD is likely to be associated with logical-mathematical, interpersonal, and intrapersonal profiles.

  14. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  15. Item difficulty of multiple choice tests dependant on different item response formats – An experiment in fundamental research on psychological assessment

    Directory of Open Access Journals (Sweden)

    KLAUS D. KUBINGER

    2007-12-01

    Full Text Available Multiple choice response formats are problematical as an item is often scored as solved simply because the test-taker is a lucky guesser. Instead of applying pertinent IRT models which take guessing effects into account, a pragmatic approach of re-conceptualizing multiple choice response formats to reduce the chance of lucky guessing is considered. This paper compares the free response format with two different multiple choice formats. A common multiple choice format with a single correct response option and five distractors (“1 of 6” is used, as well as a multiple choice format with five response options, of which any number of the five is correct and the item is only scored as mastered if all the correct response options and none of the wrong ones are marked (“x of 5”. An experiment was designed, using pairs of items with exactly the same content but different response formats. 173 test-takers were randomly assigned to two test booklets of 150 items altogether. Rasch model analyses adduced a fitting item pool, after the deletion of 39 items. The resulting item difficulty parameters were used for the comparison of the different formats. The multiple choice format “1 of 6” differs significantly from “x of 5”, with a relative effect of 1.63, while the multiple choice format “x of 5” does not significantly differ from the free response format. Therefore, the lower degree of difficulty of items with the “1 of 6” multiple choice format is an indicator of relevant guessing effects. In contrast the “x of 5” multiple choice format can be seen as an appropriate substitute for free response format.

  16. Should methods of correction for multiple comparisons be applied in pharmacovigilance?

    Directory of Open Access Journals (Sweden)

    Lorenza Scotti

    2015-12-01

    Full Text Available Purpose. In pharmacovigilance, spontaneous reporting databases are devoted to the early detection of adverse event ‘signals’ of marketed drugs. A common limitation of these systems is the wide number of concurrently investigated associations, implying a high probability of generating positive signals simply by chance. However it is not clear if the application of methods aimed to adjust for the multiple testing problems are needed when at least some of the drug-outcome relationship under study are known. To this aim we applied a robust estimation method for the FDR (rFDR particularly suitable in the pharmacovigilance context. Methods. We exploited the data available for the SAFEGUARD project to apply the rFDR estimation methods to detect potential false positive signals of adverse reactions attributable to the use of non-insulin blood glucose lowering drugs. Specifically, the number of signals generated from the conventional disproportionality measures and after the application of the rFDR adjustment method was compared. Results. Among the 311 evaluable pairs (i.e., drug-event pairs with at least one adverse event report, 106 (34% signals were considered as significant from the conventional analysis. Among them 1 resulted in false positive signals according to rFDR method. Conclusions. The results of this study seem to suggest that when a restricted number of drug-outcome pairs is considered and warnings about some of them are known, multiple comparisons methods for recognizing false positive signals are not so useful as suggested by theoretical considerations.

  17. Comparison of Sleep Latency and Number of SOREMPs in the Home and Hospital With a Modified Multiple Sleep Latency Test: A Randomized Crossover Study.

    Science.gov (United States)

    Beiske, Kornelia K; Sand, Trond; Rugland, Eyvind; Stavem, Knut

    2017-05-01

    Comparison of mean sleep latencies and number of sleep-onset rapid eye movement periods (SOREMPs) between modified multiple sleep latency test (MSLT) performed in the unattended home and in-hospital laboratory setting. A randomized crossover single-blinded design. Thirty-four subjects referred to MSLT for suspected hypersomnia or narcolepsy were included. Participants were randomized to perform modified MSLT in the unattended home or in the hospital first. Scores in the two settings were compared using Wilcoxon signed-rank test or exact McNemar test. Agreement between home and hospital categorized mean sleep latency and number of SOREMPs was assessed using simple kappa (κ) and proportion agreement. Agreement between home and hospital mean sleep latency was assessed using a Bland-Altman plot and an intraclass correlation coefficient. There was no difference between home and hospital assessment of mean sleep latency (P = 0.86). Two or more SOREMPs were found more frequently on modified MSLTs performed at home compared with those at the hospital (7 and 2, respectively; P = 0.025). Agreement was moderate for categorized sleep latency (κ = 0.53) and fair for categorized SOREMPs (κ = 0.39) in the 2 settings. Analysis of mean sleep latency using intraclass correlation coefficient showed a very good agreement between the two settings. Group mean sleep latency for home modified MSLTs seems to be reliable compared with that for the attended sleep-laboratory setting. Higher rate of SOREMP in the unattended home suggests that napping in a familiar environment facilitates the transition into REM sleep. Further studies are needed to assess the normal limit, sensitivity, and specificity for SOREMP at home before the clinical utility of home-based napping can be determined.

  18. Comparison of Parenting Style in Single Child and Multiple Children Families

    OpenAIRE

    Masoumeh Alidosti; Seyedeh Leila Dehghani; Akbar Babaei-Heydarabadi; Elahe Tavassoli

    2016-01-01

    Background and Purpose: Family is the first and the most important structure in human civilization in which social lifestyles, mutual understanding, and compatibility is learned. Studies have shown that parenting style, is one the most important and fundamental factors in personality development. The purpose of this study was comparison of parenting style in single child and multiple children families. Materials and Methods: This study, in total, 152 mothers from Andimeshk city, Iran, wer...

  19. Restoration of γ-ray multiplicity distributions from experiments with low efficiency multiplicity filters

    International Nuclear Information System (INIS)

    Bellia, G.; Del Zoppo, A.; Migneco, E.; Russo, G.; Istituto Nazionale di Fisica Nucleare, Catania

    1984-01-01

    The restoration of γ-ray multiplicity distributions from experimental p-fold coincidence distributions is discussed. It is shown that the restoration of the multiplicity from measurements with low total detection efficiency is an 'incorrectly posed problem'. While in the literature the analysis of the experimental data has been attempted only in terms of the lowest central moments of the multiplicity distribution, in this paper an unfolding method based on the minimization of the directioned discrepancies in the probability space is used. The method is found to work very well even if the total efficiency Ω <= 0.1. Realistic tests and a comparison with the usual method of analysis are presented. (orig.)

  20. Kernel Machine SNP-set Testing under Multiple Candidate Kernels

    Science.gov (United States)

    Wu, Michael C.; Maity, Arnab; Lee, Seunggeun; Simmons, Elizabeth M.; Harmon, Quaker E.; Lin, Xinyi; Engel, Stephanie M.; Molldrem, Jeffrey J.; Armistead, Paul M.

    2013-01-01

    Joint testing for the cumulative effect of multiple single nucleotide polymorphisms grouped on the basis of prior biological knowledge has become a popular and powerful strategy for the analysis of large scale genetic association studies. The kernel machine (KM) testing framework is a useful approach that has been proposed for testing associations between multiple genetic variants and many different types of complex traits by comparing pairwise similarity in phenotype between subjects to pairwise similarity in genotype, with similarity in genotype defined via a kernel function. An advantage of the KM framework is its flexibility: choosing different kernel functions allows for different assumptions concerning the underlying model and can allow for improved power. In practice, it is difficult to know which kernel to use a priori since this depends on the unknown underlying trait architecture and selecting the kernel which gives the lowest p-value can lead to inflated type I error. Therefore, we propose practical strategies for KM testing when multiple candidate kernels are present based on constructing composite kernels and based on efficient perturbation procedures. We demonstrate through simulations and real data applications that the procedures protect the type I error rate and can lead to substantially improved power over poor choices of kernels and only modest differences in power versus using the best candidate kernel. PMID:23471868

  1. A multiple objective test assembly approach for exposure control problems in Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    Theo J.H.M. Eggen

    2010-01-01

    Full Text Available Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has to be maximized, item compromise has to be minimized, and pool usage has to be optimized. In this paper, a multiple objectives method is developed to deal with both types of exposure problems. In this method, exposure control parameters based on observed exposure rates are implemented as weights for the information in the item selection procedure. The method does not need time consuming simulation studies, and it can be implemented conditional on ability level. The method is compared with Sympson Hetter method for exposure control, with the Progressive method and with alphastratified testing. The results show that the method is successful in dealing with both kinds of exposure problems.

  2. Comparison of computer code calculations with FEBA test data

    International Nuclear Information System (INIS)

    Zhu, Y.M.

    1988-06-01

    The FEBA forced feed reflood experiments included base line tests with unblocked geometry. The experiments consisted of separate effect tests on a full-length 5x5 rod bundle. Experimental cladding temperatures and heat transfer coefficients of FEBA test No. 216 are compared with the analytical data postcalculated utilizing the SSYST-3 computer code. The comparison indicates a satisfactory matching of the peak cladding temperatures, quench times and heat transfer coefficients for nearly all axial positions. This agreement was made possible by the use of an artificially adjusted value of the empirical code input parameter in the heat transfer for the dispersed flow regime. A limited comparison of test data and calculations using the RELAP4/MOD6 transient analysis code are also included. In this case the input data for the water entrainment fraction and the liquid weighting factor in the heat transfer for the dispersed flow regime were adjusted to match the experimental data. On the other hand, no fitting of the input parameters was made for the COBRA-TF calculations which are included in the data comparison. (orig.) [de

  3. Comparison of Deep Learning With Multiple Machine Learning Methods and Metrics Using Diverse Drug Discovery Data Sets.

    Science.gov (United States)

    Korotcov, Alexandru; Tkachenko, Valery; Russo, Daniel P; Ekins, Sean

    2017-12-04

    Machine learning methods have been applied to many data sets in pharmaceutical research for several decades. The relative ease and availability of fingerprint type molecular descriptors paired with Bayesian methods resulted in the widespread use of this approach for a diverse array of end points relevant to drug discovery. Deep learning is the latest machine learning algorithm attracting attention for many of pharmaceutical applications from docking to virtual screening. Deep learning is based on an artificial neural network with multiple hidden layers and has found considerable traction for many artificial intelligence applications. We have previously suggested the need for a comparison of different machine learning methods with deep learning across an array of varying data sets that is applicable to pharmaceutical research. End points relevant to pharmaceutical research include absorption, distribution, metabolism, excretion, and toxicity (ADME/Tox) properties, as well as activity against pathogens and drug discovery data sets. In this study, we have used data sets for solubility, probe-likeness, hERG, KCNQ1, bubonic plague, Chagas, tuberculosis, and malaria to compare different machine learning methods using FCFP6 fingerprints. These data sets represent whole cell screens, individual proteins, physicochemical properties as well as a data set with a complex end point. Our aim was to assess whether deep learning offered any improvement in testing when assessed using an array of metrics including AUC, F1 score, Cohen's kappa, Matthews correlation coefficient and others. Based on ranked normalized scores for the metrics or data sets Deep Neural Networks (DNN) ranked higher than SVM, which in turn was ranked higher than all the other machine learning methods. Visualizing these properties for training and test sets using radar type plots indicates when models are inferior or perhaps over trained. These results also suggest the need for assessing deep learning further

  4. Evaluation and Comparison of the Position of the Apical Constriction in Single-root and Multiple-root Teeth

    Directory of Open Access Journals (Sweden)

    Alireza Farhad

    2017-12-01

    Full Text Available Introduction: Precise knowledge of the location of the apical constriction is essential to root canal treatment and long-term prognosis. Considering the differences in the apical constriction and size of the roots in single- and multiple-root teeth in various races, examination and comparison of the location of the apical constriction in single-root and multiple-root teeth are of paramount importance. The present studies aimed to measure and compare the distance of the apical constriction from the apical foramen and anatomical apex in single-root and multiple-root teeth. Materials and Methods: In this cross-sectional study, 60 roots of single-rooted teeth and 60 roots of multiple-rooted teeth were collected from the patients referring to the health centers in Isfahan, Iran. After cleansing and disinfecting the surface of the roots, the surface of the teeth was washed with hypochlorite. Based on the direction of the apical foramen, a longitudinal cut was made in the same direction, and the roots were examined microscopically at the magnification of 25. Following that, the distance of the apical constriction from the apical foramen and anatomical apex was measured using a digital camera. In addition, mean and standard deviation of the obtained distance values were determined. Distances in the single-root and multiple-root teeth were compared using independent t-test, at the significance level of Results: Mean distance between the apical constriction and apical foramen was 0.86±0.33 mm in the single-root teeth and 0.072±0.27 mm in the multiple-root teeth. Mean distance between the apical constriction and anatomical apex was 1.14±0.36 mm in the single-root teeth and 1.03±0.36 mm in the multiple-root teeth. Moreover, the results of independent t-test showed the distance of the apical constriction from the apical foramen to be significant between single-root and multiple-rooted teeth (P=0.013. However, the distance between the apical constriction

  5. A Comparison of Three Tests of Mediation

    Science.gov (United States)

    Warbasse, Rosalia E.

    2009-01-01

    A simulation study was conducted to evaluate the performance of three tests of mediation: the bias-corrected and accelerated bootstrap (Efron & Tibshirani, 1993), the asymmetric confidence limits test (MacKinnon, 2008), and a multiple regression approach described by Kenny, Kashy, and Bolger (1998). The evolution of these methods is reviewed and…

  6. "None of the above" as a correct and incorrect alternative on a multiple-choice test: implications for the testing effect.

    Science.gov (United States)

    Odegard, Timothy N; Koen, Joshua D

    2007-11-01

    Both positive and negative testing effects have been demonstrated with a variety of materials and paradigms (Roediger & Karpicke, 2006b). The present series of experiments replicate and extend the research of Roediger and Marsh (2005) with the addition of a "none-of-the-above" response option. Participants (n=32 in both experiments) read a set of passages, took an initial multiple-choice test, completed a filler task, and then completed a final cued-recall test (Experiment 1) or multiple-choice test (Experiment 2). Questions were manipulated on the initial multiple-choice test by adding a "none-of-the-above" response alternative (choice "E") that was incorrect ("E" Incorrect) or correct ("E" Correct). The results from both experiments demonstrated that the positive testing effect was negated when the "none-of-the-above" alternative was the correct response on the initial multiple-choice test, but was still present when the "none-of-the-above" alternative was an incorrect response.

  7. Multiple-vent programme to test the pressure suppression system

    International Nuclear Information System (INIS)

    Aust, E.; Schwan, H.; Vollbrandt, I.

    1979-01-01

    Three pre-tests with a multiple vent configuration have been performed at the GKSS pressure suppression test facility. First test results indicate significant chugging events with occur periodically with 0.4 to 0.2 Hz. These events appear simultaneously in less than 10 ms at the exit of the three vent pipes and cause pressure pulses in the range of 3 bar. This report gives a short description of the test facility and presents the boundary conditions of the test facility and presents the boundary conditions of the three pre-tests, test results and a first valuation of the experimental informations. (orig.) [de

  8. On the Equivalence of Constructed-Response and Multiple-Choice Tests.

    Science.gov (United States)

    Traub, Ross E.; Fisher, Charles W.

    Two sets of mathematical reasoning and two sets of verbal comprehension items were cast into each of three formats--constructed response, standard multiple-choice, and Coombs multiple-choice--in order to assess whether tests with indentical content but different formats measure the same attribute, except for possible differences in error variance…

  9. DHS small-scale safety and thermal testing of improvised explosives-comparison of testing performance

    International Nuclear Information System (INIS)

    Reynolds, J G; Hsu, P C; Sandstrom, M M; Brown, G W; Warner, K F; Phillips, J J; Shelley, T J; Reyes, J A

    2014-01-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.

  10. A Spreadsheet Tool for Learning the Multiple Regression F-Test, T-Tests, and Multicollinearity

    Science.gov (United States)

    Martin, David

    2008-01-01

    This note presents a spreadsheet tool that allows teachers the opportunity to guide students towards answering on their own questions related to the multiple regression F-test, the t-tests, and multicollinearity. The note demonstrates approaches for using the spreadsheet that might be appropriate for three different levels of statistics classes,…

  11. Multiple Score Comparison: a network meta-analysis approach to comparison and external validation of prognostic scores

    Directory of Open Access Journals (Sweden)

    Sarah R. Haile

    2017-12-01

    Full Text Available Abstract Background Prediction models and prognostic scores have been increasingly popular in both clinical practice and clinical research settings, for example to aid in risk-based decision making or control for confounding. In many medical fields, a large number of prognostic scores are available, but practitioners may find it difficult to choose between them due to lack of external validation as well as lack of comparisons between them. Methods Borrowing methodology from network meta-analysis, we describe an approach to Multiple Score Comparison meta-analysis (MSC which permits concurrent external validation and comparisons of prognostic scores using individual patient data (IPD arising from a large-scale international collaboration. We describe the challenges in adapting network meta-analysis to the MSC setting, for instance the need to explicitly include correlations between the scores on a cohort level, and how to deal with many multi-score studies. We propose first using IPD to make cohort-level aggregate discrimination or calibration scores, comparing all to a common comparator. Then, standard network meta-analysis techniques can be applied, taking care to consider correlation structures in cohorts with multiple scores. Transitivity, consistency and heterogeneity are also examined. Results We provide a clinical application, comparing prognostic scores for 3-year mortality in patients with chronic obstructive pulmonary disease using data from a large-scale collaborative initiative. We focus on the discriminative properties of the prognostic scores. Our results show clear differences in performance, with ADO and eBODE showing higher discrimination with respect to mortality than other considered scores. The assumptions of transitivity and local and global consistency were not violated. Heterogeneity was small. Conclusions We applied a network meta-analytic methodology to externally validate and concurrently compare the prognostic properties

  12. Default mode network links to visual hallucinations: A comparison between Parkinson's disease and multiple system atrophy.

    Science.gov (United States)

    Franciotti, Raffaella; Delli Pizzi, Stefano; Perfetti, Bernardo; Tartaro, Armando; Bonanni, Laura; Thomas, Astrid; Weis, Luca; Biundo, Roberta; Antonini, Angelo; Onofrj, Marco

    2015-08-01

    Studying default mode network activity or connectivity in different parkinsonisms, with or without visual hallucinations, could highlight its roles in clinical phenotypes' expression. Multiple system atrophy is the archetype of parkinsonism without visual hallucinations, variably appearing instead in Parkinson's disease (PD). We aimed to evaluate default mode network functions in multiple system atrophy in comparison with PD. Functional magnetic resonance imaging evaluated default mode network activity and connectivity in 15 multiple system atrophy patients, 15 healthy controls, 15 early PD patients matched for disease duration, 30 severe PD patients (15 with and 15 without visual hallucinations), matched with multiple system atrophy for disease severity. Cortical thickness and neuropsychological evaluations were also performed. Multiple system atrophy had reduced default mode network activity compared with controls and PD with hallucinations, and no differences with PD (early or severe) without hallucinations. In PD with visual hallucinations, activity and connectivity was preserved compared with controls and higher than in other groups. In early PD, connectivity was lower than in controls but higher than in multiple system atrophy and severe PD without hallucinations. Cortical thickness was reduced in severe PD, with and without hallucinations, and correlated only with disease duration. Higher anxiety scores were found in patients without hallucinations. Default mode network activity and connectivity was higher in PD with visual hallucinations and reduced in multiple system atrophy and PD without visual hallucinations. Cortical thickness comparisons suggest that functional, rather than structural, changes underlie the activity and connectivity differences. © 2015 International Parkinson and Movement Disorder Society.

  13. A permutation-based multiple testing method for time-course microarray experiments

    Directory of Open Access Journals (Sweden)

    George Stephen L

    2009-10-01

    Full Text Available Abstract Background Time-course microarray experiments are widely used to study the temporal profiles of gene expression. Storey et al. (2005 developed a method for analyzing time-course microarray studies that can be applied to discovering genes whose expression trajectories change over time within a single biological group, or those that follow different time trajectories among multiple groups. They estimated the expression trajectories of each gene using natural cubic splines under the null (no time-course and alternative (time-course hypotheses, and used a goodness of fit test statistic to quantify the discrepancy. The null distribution of the statistic was approximated through a bootstrap method. Gene expression levels in microarray data are often complicatedly correlated. An accurate type I error control adjusting for multiple testing requires the joint null distribution of test statistics for a large number of genes. For this purpose, permutation methods have been widely used because of computational ease and their intuitive interpretation. Results In this paper, we propose a permutation-based multiple testing procedure based on the test statistic used by Storey et al. (2005. We also propose an efficient computation algorithm. Extensive simulations are conducted to investigate the performance of the permutation-based multiple testing procedure. The application of the proposed method is illustrated using the Caenorhabditis elegans dauer developmental data. Conclusion Our method is computationally efficient and applicable for identifying genes whose expression levels are time-dependent in a single biological group and for identifying the genes for which the time-profile depends on the group in a multi-group setting.

  14. Bayesian models based on test statistics for multiple hypothesis testing problems.

    Science.gov (United States)

    Ji, Yuan; Lu, Yiling; Mills, Gordon B

    2008-04-01

    We propose a Bayesian method for the problem of multiple hypothesis testing that is routinely encountered in bioinformatics research, such as the differential gene expression analysis. Our algorithm is based on modeling the distributions of test statistics under both null and alternative hypotheses. We substantially reduce the complexity of the process of defining posterior model probabilities by modeling the test statistics directly instead of modeling the full data. Computationally, we apply a Bayesian FDR approach to control the number of rejections of null hypotheses. To check if our model assumptions for the test statistics are valid for various bioinformatics experiments, we also propose a simple graphical model-assessment tool. Using extensive simulations, we demonstrate the performance of our models and the utility of the model-assessment tool. In the end, we apply the proposed methodology to an siRNA screening and a gene expression experiment.

  15. Comparison of the sensitivities of the Buehler test and the guinea pig maximization test for predictive testing of contact allergy

    DEFF Research Database (Denmark)

    Frankild, S; Vølund, A; Wahlberg, J E

    2001-01-01

    International test guidelines, such as the Organisation for Economic Cooperation and Development (OECD) guideline #406, recommend 2 guinea pig methods for testing of the contact allergenic potential of chemicals: the Guinea Pig Maximization Test (GPMT) and the Buehler test. Previous comparisons...

  16. Compaction comparison testing using a modified impact soil tester and nuclear density gauge

    Energy Technology Data Exchange (ETDEWEB)

    Erchul, R.A.

    1999-07-01

    The purpose of this paper is to compare test results of a modified Impact Soil Tester (IST) on compacted soil with data obtained from the same soil using a nuclear density gauge at the US Army Corp of Engineer's Buena Vista Flood Wall project in Buena Vista, Virginia. The tests were run during construction of the earth flood wall during the summer of 1996. This comparison testing demonstrated the credibility of the procedure developed for the IST as a compacting testing device. The comparison data was obtained on a variety of soils ranging from silty sands to clays. The Flood Wall comparison compaction data for 90% Standard Proctor shows that the results of the IST as modified are consistent with the nuclear density gauge 89% of the time for all types of soil tested. However, if the soils are more cohesive than the results are consistent with the nuclear density gauge 97% of the time. In addition these comparison tests are in general agreement with comparison compaction testing using the same testing techniques and methods of compacted backfill in utility trenches conducted earlier for the Public Works Department, Chesterfield County, Virginia.

  17. Compaction comparison testing using a modified impact soil tester and nuclear density gauge

    International Nuclear Information System (INIS)

    Erchul, R.A.

    1999-01-01

    The purpose of this paper is to compare test results of a modified Impact Soil Tester (IST) on compacted soil with data obtained from the same soil using a nuclear density gauge at the US Army Corp of Engineer's Buena Vista Flood Wall project in Buena Vista, Virginia. The tests were run during construction of the earth flood wall during the summer of 1996. This comparison testing demonstrated the credibility of the procedure developed for the IST as a compacting testing device. The comparison data was obtained on a variety of soils ranging from silty sands to clays. The Flood Wall comparison compaction data for 90% Standard Proctor shows that the results of the IST as modified are consistent with the nuclear density gauge 89% of the time for all types of soil tested. However, if the soils are more cohesive than the results are consistent with the nuclear density gauge 97% of the time. In addition these comparison tests are in general agreement with comparison compaction testing using the same testing techniques and methods of compacted backfill in utility trenches conducted earlier for the Public Works Department, Chesterfield County, Virginia

  18. Testing effect of a drug using multiple nested models for the dose–response

    DEFF Research Database (Denmark)

    Baayen, C.; Hougaard, P.; Pipper, C. B.

    2015-01-01

    of the assumed dose–response model. Bretz et al. (2005, Biometrics 61, 738–748) suggested a combined approach, which selects one or more suitable models from a set of candidate models using a multiple comparison procedure. The method initially requires a priori estimates of any non-linear parameters...

  19. Comparison of Masking Level Difference in Patients with Multiple Sclerosis and Healthy Control Group

    Directory of Open Access Journals (Sweden)

    Soghrat Faghihzadeh

    2012-03-01

    Full Text Available Background and Aim: Multiple sclerosis (MS is a neurological disorder that involves central nervous system. Studies have showed that multiple sclerosis affects behavioral central auditory tests, such as masking release or masking level difference (MLD. The purpose of this study is to compare the masking level difference between multiple sclerosis patients and normal subjects.Methods: This cross sectional and non-interventional study was conducted on 32 multiple sclerosis patients aged between 20-50 years and 32 controls matched for age and gender in Faculty of Rehabilitation, Tehran University of Medical Sciences. masking level difference test was performed on each subject.Results: The mean masking level difference in the two groups was significantly different (p<0.01 however, gender did not prove to play a role in this difference.Conclusion: As part of the multiple sclerosis diagnosis panel, masking level difference test is an efficient modality for evaluation of hearing impairment and monitoring of rehabilitation progress.

  20. Hydrologic test plans for large-scale, multiple-well tests in support of site characterization at Hanford, Washington

    International Nuclear Information System (INIS)

    Rogers, P.M.; Stone, R.; Lu, A.H.

    1985-01-01

    The Basalt Waste Isolation Project is preparing plans for tests and has begun work on some tests that will provide the data necessary for the hydrogeologic characterization of a site located on a United States government reservation at Hanford, Washington. This site is being considered for the Nation's first geologic repository of high level nuclear waste. Hydrogeologic characterization of this site requires several lines of investigation which include: surface-based small-scale tests, testing performed at depth from an exploratory shaft, geochemistry investigations, regional studies, and site-specific investigations using large-scale, multiple-well hydraulic tests. The large-scale multiple-well tests are planned for several locations in and around the site. These tests are being designed to provide estimates of hydraulic parameter values of the geologic media, chemical properties of the groundwater, and hydrogeologic boundary conditions at a scale appropriate for evaluating repository performance with respect to potential radionuclide transport

  1. The Dental Hygiene Aptitude Tests and the American College Testing Program Tests as Predictors of Scores on the National Board Dental Hygiene Examination.

    Science.gov (United States)

    Longenbecker, Sueann; Wood, Peter H.

    1984-01-01

    Scores from the National Board Dental Hygiene Examination (NBDHE) served as the criterion variable in a comparison of the predictive validity of the Dental Hygiene Aptitude Tests (DHAT) and the ACT Assessment tests. The DHAT-Science and Verbal tests combined to produce the highest multiple correlation with NBDHE scores. (Author/DWH)

  2. Comparison of Automated Graphical User Interface Testing Tools

    OpenAIRE

    Gaber, Domen

    2018-01-01

    The thesis presents the analysis of modern tools for automated testing of various web based user interfaces. The purpose of the work is to compare specific test automation solutions and point out the most suitable test automation tool amongst them. One of the main goals of test automation is to gain faster execution when compared to manual testing and overall cost deduction. There are multiple test automation solutions available on the market, which differ in complexity of use, type of o...

  3. Impact of Answer-Switching Behavior on Multiple-Choice Test Scores in Higher Education

    Directory of Open Access Journals (Sweden)

    Ramazan BAŞTÜRK

    2011-06-01

    Full Text Available The multiple- choice format is one of the most popular selected-response item formats used in educational testing. Researchers have shown that Multiple-choice type test is a useful vehicle for student assessment in core university subjects that usually have large student numbers. Even though the educators, test experts and different test recourses maintain the idea that the first answer should be retained, many researchers argued that this argument is not dependent with empirical findings. The main question of this study is to examine how the answer switching behavior affects the multiple-choice test score. Additionally, gender differences and relationship between number of answer switching behavior and item parameters (item difficulty and item discrimination were investigated. The participants in this study consisted of 207 upper-level College of Education students from mid-sized universities. A Midterm exam consisted of 20 multiple-choice questions was used. According to the result of this study, answer switching behavior statistically increase test scores. On the other hand, there is no significant gender difference in answer-switching behavior. Additionally, there is a significant negative relationship between answer switching behavior and item difficulties.

  4. Comparison of Test and Finite Element Analysis for Two Full-Scale Helicopter Crash Tests

    Science.gov (United States)

    Annett, Martin S.; Horta,Lucas G.

    2011-01-01

    Finite element analyses have been performed for two full-scale crash tests of an MD-500 helicopter. The first crash test was conducted to evaluate the performance of a composite deployable energy absorber under combined flight loads. In the second crash test, the energy absorber was removed to establish the baseline loads. The use of an energy absorbing device reduced the impact acceleration levels by a factor of three. Accelerations and kinematic data collected from the crash tests were compared to analytical results. Details of the full-scale crash tests and development of the system-integrated finite element model are briefly described along with direct comparisons of acceleration magnitudes and durations for the first full-scale crash test. Because load levels were significantly different between tests, models developed for the purposes of predicting the overall system response with external energy absorbers were not adequate under more severe conditions seen in the second crash test. Relative error comparisons were inadequate to guide model calibration. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used for the second full-scale crash test. The calibrated parameter set reduced 2-norm prediction error by 51% but did not improve impact shape orthogonality.

  5. Comparison of transient PCRV model test results with analysis

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Belytschko, T.B.

    1979-01-01

    Comparisons are made of transient data derived from simple models of a reactor containment vessel with analytical solutions. This effort is a part of the ongoing process of development and testing of the DYNAPCON computer code. The test results used in these comparisons were obtained from scaled models of the British sodium cooled fast breeder program. The test structure is a scaled model of a cylindrically shaped reactor containment vessel made of concrete. This concrete vessel is prestressed axially by holddown bolts spanning the top and bottom slabs along the cylindrical walls, and is also prestressed circumferentially by a number of cables wrapped around the vessel. For test purposes this containment vessel is partially filled with water, which comes in direct contact with the vessel walls. The explosive charge is immersed in the pool of water and is centrally suspended from the top of the vessel. The tests are very similar to the series of tests made for the COVA experimental program, but the vessel here is the prestressed concrete container. (orig.)

  6. Multiple-choice test of energy and momentum concepts

    OpenAIRE

    Singh, Chandralekha; Rosengrant, David

    2016-01-01

    We investigate student understanding of energy and momentum concepts at the level of introductory physics by designing and administering a 25-item multiple choice test and conducting individual interviews. We find that most students have difficulty in qualitatively interpreting basic principles related to energy and momentum and in applying them in physical situations.

  7. Assessment Guide for Educators: A Content Comparison--2002 Series Test and the Current GED® Test

    Science.gov (United States)

    GED Testing Service, 2017

    2017-01-01

    This report provides a content comparison for the 2002 Series GED® test and the current GED® for the following test topic areas: (1) Mathematical Reasoning; (2) Reasoning through Language Arts; (3) Science; and (4) Social Studies.

  8. A Powerful Test for Comparing Multiple Regression Functions.

    Science.gov (United States)

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  9. Developing the multiple stress-strain creep recovery (MS-SCR) test

    Science.gov (United States)

    Elnasri, Mahmoud; Airey, Gordon; Thom, Nick

    2018-04-01

    While most published work from Europe has been concerned with evaluating binders' resistance to rutting based on their stiffness (deformation resistance), work originating in the US has mainly been concerned with ranking binders based on their recoverability in a multiple stress form. This paper details the design of a new modified multiple stress-strain creep recovery (MS-SCR) test. The test is designed to evaluate binders' rutting resistance based on two rutting resistance mechanisms: stiffness and recoverability. A preliminary investigation is presented in this paper followed by details of the design of the new modified test. A 40/60 penetration grade bitumen and bitumen-filler mastics prepared with three filler concentrations (35%, 50%, and 65% filler content by mass of mastic) were tested. In addition, two polymer modified bitumens (PMBs) using the same base bitumen type were examined for validation. Two parameters are introduced to characterise the short and long recovery in the new test. In terms of stiffness, the test allows the behaviour of binders at different stress levels and loading cycles to be studied and produces a new parameter that can quantify the degree of modification. Finally, a relationship between nonlinearity and normal force in the test was investigated.

  10. A simplified approach for evaluating multiple test outcomes and multiple disease states in relation to the exercise thallium-201 stress test in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Pollock, S.G.; Watson, D.D.; Gibson, R.S.; Beller, G.A.; Kaul, S.

    1989-01-01

    This study describes a simplified approach for the interpretation of electrocardiographic and thallium-201 imaging data derived from the same patient during exercise. The 383 patients in this study had also undergone selective coronary arteriography within 3 months of the exercise test. This matrix approach allows for multiple test outcomes (both tests positive, both negative, 1 test positive and 1 negative) and multiple disease states (no coronary artery disease vs 1-vessel vs multivessel coronary artery disease). Because this approach analyzes the results of 2 test outcomes simultaneously rather than serially, it also negates the lack of test independence, if such an effect is present. It is also demonstrated that ST-segment depression on the electrocardiogram and defects on initial thallium-201 images provide conditionally independent information regarding the presence of coronary artery disease in patients without prior myocardial infarction. In contrast, ST-segment depression on the electrocardiogram and redistribution on the delayed thallium-201 images may not provide totally independent information regarding the presence of exercise-induced ischemia in patients with or without myocardial infarction

  11. Multiple testing corrections in quantitative proteomics: A useful but blunt tool.

    Science.gov (United States)

    Pascovici, Dana; Handler, David C L; Wu, Jemma X; Haynes, Paul A

    2016-09-01

    Multiple testing corrections are a useful tool for restricting the FDR, but can be blunt in the context of low power, as we demonstrate by a series of simple simulations. Unfortunately, in proteomics experiments low power can be common, driven by proteomics-specific issues like small effects due to ratio compression, and few replicates due to reagent high cost, instrument time availability and other issues; in such situations, most multiple testing corrections methods, if used with conventional thresholds, will fail to detect any true positives even when many exist. In this low power, medium scale situation, other methods such as effect size considerations or peptide-level calculations may be a more effective option, even if they do not offer the same theoretical guarantee of a low FDR. Thus, we aim to highlight in this article that proteomics presents some specific challenges to the standard multiple testing corrections methods, which should be employed as a useful tool but not be regarded as a required rubber stamp. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Comparison of Critical Flow Models' Evaluations for SBLOCA Tests

    International Nuclear Information System (INIS)

    Kim, Yeon Sik; Park, Hyun Sik; Cho, Seok

    2016-01-01

    A comparison of critical flow models between the Trapp-Ransom and Henry-Fauske models for all SBLOCA (small break loss of coolant accident) scenarios of the ATLAS (Advanced thermal-hydraulic test loop for accident simulation) facility was performed using the MARS-KS code. For the comparison of the two critical models, the accumulated break mass was selected as the main parameter for the comparison between the analyses and tests. Four cases showed the same respective discharge coefficients between the two critical models, e.g., 6' CL (cold leg) break and 25%, 50%, and 100% DVI (direct vessel injection) breaks. In the case of the 4' CL break, no reasonable results were obtained with any possible Cd values. In addition, typical system behaviors, e.g., PZR (pressurizer) pressure and collapsed core water level, were also compared between the two critical models. Four cases showed the same respective discharge coefficients between the two critical models, e.g., 6' CL break and 25%, 50%, and 100% DVI breaks. In the case of the 4' CL break, no reasonable results were obtained with any possible Cd values. In addition, typical system behaviors, e.g., PZR pressure and collapsed core water level, were also compared between the two critical models. From the comparison between the two critical models for the CL breaks, the Trapp-Ransom model predicted quite well with respect to the other model for the smallest and larger breaks, e.g., 2', 6', and 8.5' CL breaks. In addition, from the comparison between the two critical models for the DVI breaks, the Trapp-Ransom model predicted quite well with respect to the other model for the smallest and larger breaks, e.g., 5%, 50%, and 100% DVI breaks. In the case of the 50% and 100% breaks, the two critical models predicted the test data quite well.

  13. Comparison of Parenting Style in Single Child and Multiple Children Families

    Directory of Open Access Journals (Sweden)

    Masoumeh Alidosti

    2016-06-01

    Full Text Available Background and Purpose: Family is the first and the most important structure in human civilization in which social lifestyles, mutual understanding, and compatibility is learned. Studies have shown that parenting style, is one the most important and fundamental factors in personality development. The purpose of this study was comparison of parenting style in single child and multiple children families. Materials and Methods: This study, in total, 152 mothers from Andimeshk city, Iran, were selected by random sampling. Data were collected from a health-care center was chosen randomly, mothers who had 5-7 years old children were enrolled in this study. The data collecting tool was the questionnaire which investigates permissive, authoritative, and authoritarian parenting styles in parents. After data entry in SPSS software, the collected data were analyzed by ANOVA, independent t-test, and Pearson correlation test. Results: The mean age of the participants was 32.71 ± 5.39 years old participated in this study. 69 mothers (45.4% had one child, 53 (34.9% had 2 children, and 30 mothers (19.7% had 3 and more children. The mean score of permissive parenting style was 19.97 ± 5.13 in single child families; the mean score of authoritative (19.56 ± 4.70 and authoritarian parenting style (34.50 ± 2.81 that difference was significantly (P < 0.050. Conclusion: According to the results of this study, it seems that having more children would make parents more logical and paves the way for upbringing children. Therefore, it is recommended to plan some educational programs about this issue for parents.

  14. The optimal hormonal replacement modality selection for multiple organ procurement from brain-dead organ donors.

    Science.gov (United States)

    Mi, Zhibao; Novitzky, Dimitri; Collins, Joseph F; Cooper, David Kc

    2015-01-01

    The management of brain-dead organ donors is complex. The use of inotropic agents and replacement of depleted hormones (hormonal replacement therapy) is crucial for successful multiple organ procurement, yet the optimal hormonal replacement has not been identified, and the statistical adjustment to determine the best selection is not trivial. Traditional pair-wise comparisons between every pair of treatments, and multiple comparisons to all (MCA), are statistically conservative. Hsu's multiple comparisons with the best (MCB) - adapted from the Dunnett's multiple comparisons with control (MCC) - has been used for selecting the best treatment based on continuous variables. We selected the best hormonal replacement modality for successful multiple organ procurement using a two-step approach. First, we estimated the predicted margins by constructing generalized linear models (GLM) or generalized linear mixed models (GLMM), and then we applied the multiple comparison methods to identify the best hormonal replacement modality given that the testing of hormonal replacement modalities is independent. Based on 10-year data from the United Network for Organ Sharing (UNOS), among 16 hormonal replacement modalities, and using the 95% simultaneous confidence intervals, we found that the combination of thyroid hormone, a corticosteroid, antidiuretic hormone, and insulin was the best modality for multiple organ procurement for transplantation.

  15. ISP42 (PANDA Tests) - Open Phase Comparison Report

    International Nuclear Information System (INIS)

    2003-05-01

    PANDA is a large-scale facility, which has been constructed at the Paul Scherrer Institute (PSI) for the investigation of both overall dynamic response and the key phenomena of passive containment systems during the long-term heat removal phase for Advanced Light Water Reactors (ALWRs). Using a modular concept with a basic set of cylindrical vessels and connecting piping, the facility can be adapted to simulate different passive containment designs. Following a proposal, the OECD/NEA Committee on the Safety of Nuclear Installations approved, at its meeting on December 3-5, 1997, a new International Standard Problem (ISP) involving a test in the PANDA facility, based on a recommendation from the Principal Working Group 2 (PWG2) on System Behaviour. The main interest for this ISP is code validation in relation to a range of LWR and advanced LWR (ALWR) (mainly) containment issues that have been designated as important and involving thermalhydraulic phenomena. The ISP-PANDA test for defined six phases (A to F) was performed on 21/22 April 1998. Since the first part of ISP-42 was going to be conducted as a 'double- blind' or 'blind' exercise, the experimental data was locked. The 'blind' phase calculational results compared to experimental data are presented in the report entitled 'ISP-42 (PANDA Tests ) Blind Phase Comparison'. In the second part, the 'open' exercise has been conducted by providing the ISP-42 PANDA test data to the participants and by performing post-test analysis. The results of the 'open' phase are presented in the present report. 'Open' phase submissions, comparisons, and analyses for ISP-42 are based on the outcome of the results presented in the 'blind' phase report of ISP-42. The experimental data was distributed to all ISP-42 participants for their post-test calculations, 20 June 2000. 'Open' phase analyses of some of the ISP-42 participants, were completely received by the end of January 2001. There were 27 new submissions for different phases

  16. The hippocampus supports multiple cognitive processes through relational binding and comparison

    Directory of Open Access Journals (Sweden)

    Rosanna Kathleen Olsen

    2012-05-01

    Full Text Available It has been well established that the hippocampus plays a pivotal role in explicit long-term recognition memory. However, findings from amnesia, lesion and recording studies with non-human animals, eye-movement recording studies, and functional neuroimaging have recently converged upon a similar message: the functional reach of the hippocampus extends far beyond explicit recognition memory. Damage to the hippocampus affects performance on a number of cognitive tasks including recognition memory after short and long delays and visual discrimination. Additionally, with the advent of neuroimaging techniques that have fine spatial and temporal resolution, findings have emerged that show the elicitation of hippocampal responses within the first few hundred milliseconds of stimulus/task onset. These responses occur for novel and previously viewed information during a time when perceptual processing is traditionally thought to occur, and long before overt recognition responses are made. We propose that the hippocampus is obligatorily involved in the binding of disparate elements across both space and time, and in the comparison of such relational memory representations. Furthermore, the hippocampus supports relational binding and comparison with or without conscious awareness for the relational representations that are formed, retrieved and/or compared. It is by virtue of these basic binding and comparison functions that the reach of the hippocampus extends beyond long-term recognition memory and underlies task performance in multiple cognitive domains.

  17. Functional Magnetic Resonance Imaging with Concurrent Urodynamic Testing Identifies Brain Structures Involved in Micturition Cycle in Patients with Multiple Sclerosis.

    Science.gov (United States)

    Khavari, Rose; Karmonik, Christof; Shy, Michael; Fletcher, Sophie; Boone, Timothy

    2017-02-01

    Neurogenic lower urinary tract dysfunction, which is common in patients with multiple sclerosis, has a significant impact on quality of life. In this study we sought to determine brain activity processes during the micturition cycle in female patients with multiple sclerosis and neurogenic lower urinary tract dysfunction. We report brain activity on functional magnetic resonance imaging and simultaneous urodynamic testing in 23 ambulatory female patients with multiple sclerosis. Individual functional magnetic resonance imaging activation maps at strong desire to void and at initiation of voiding were calculated and averaged at Montreal Neuroimaging Institute. Areas of significant activation were identified in these average maps. Subgroup analysis was performed in patients with elicitable neurogenic detrusor overactivity or detrusor-sphincter dyssynergia. Group analysis of all patients at strong desire to void yielded areas of activation in regions associated with executive function (frontal gyrus), emotional regulation (cingulate gyrus) and motor control (putamen, cerebellum and precuneus). Comparison of the average change in activation between previously reported healthy controls and patients with multiple sclerosis showed predominantly stronger, more focal activation in the former and lower, more diffused activation in the latter. Patients with multiple sclerosis who had demonstrable neurogenic detrusor overactivity and detrusor-sphincter dyssynergia showed a trend toward distinct brain activation at full urge and at initiation of voiding respectively. We successfully studied brain activation during the entire micturition cycle in female patients with neurogenic lower urinary tract dysfunction and multiple sclerosis using a concurrent functional magnetic resonance imaging/urodynamic testing platform. Understanding the central neural processes involved in specific parts of micturition in patients with neurogenic lower urinary tract dysfunction may identify areas

  18. Accelerated Testing with Multiple Failure Modes under Several Temperature Conditions

    OpenAIRE

    Zongyue Yu; Zhiqian Ren; Junyong Tao; Xun Chen

    2014-01-01

    A complicated device may have multiple failure modes, and some of the failure modes are sensitive to low temperatures. To assess the reliability of a product with multiple failure modes, this paper presents an accelerated testing in which both of the high temperatures and the low temperatures are applied. Firstly, an acceleration model based on the Arrhenius model but accounting for the influence of both the high temperatures and low temperatures is proposed. Accordingly, an accelerated testi...

  19. Test of understanding of vectors: A reliable multiple-choice vector concept test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  20. MZDASoft: a software architecture that enables large-scale comparison of protein expression levels over multiple samples based on liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Ghanat Bari, Mehrab; Ramirez, Nelson; Wang, Zhiwei; Zhang, Jianqiu Michelle

    2015-10-15

    Without accurate peak linking/alignment, only the expression levels of a small percentage of proteins can be compared across multiple samples in Liquid Chromatography/Mass Spectrometry/Tandem Mass Spectrometry (LC/MS/MS) due to the selective nature of tandem MS peptide identification. This greatly hampers biomedical research that aims at finding biomarkers for disease diagnosis, treatment, and the understanding of disease mechanisms. A recent algorithm, PeakLink, has allowed the accurate linking of LC/MS peaks without tandem MS identifications to their corresponding ones with identifications across multiple samples collected from different instruments, tissues and labs, which greatly enhanced the ability of comparing proteins. However, PeakLink cannot be implemented practically for large numbers of samples based on existing software architectures, because it requires access to peak elution profiles from multiple LC/MS/MS samples simultaneously. We propose a new architecture based on parallel processing, which extracts LC/MS peak features, and saves them in database files to enable the implementation of PeakLink for multiple samples. The software has been deployed in High-Performance Computing (HPC) environments. The core part of the software, MZDASoft Parallel Peak Extractor (PPE), can be downloaded with a user and developer's guide, and it can be run on HPC centers directly. The quantification applications, MZDASoft TandemQuant and MZDASoft PeakLink, are written in Matlab, which are compiled with a Matlab runtime compiler. A sample script that incorporates all necessary processing steps of MZDASoft for LC/MS/MS quantification in a parallel processing environment is available. The project webpage is http://compgenomics.utsa.edu/zgroup/MZDASoft. The proposed architecture enables the implementation of PeakLink for multiple samples. Significantly more (100%-500%) proteins can be compared over multiple samples with better quantification accuracy in test cases. MZDASoft

  1. Accelerating Multiple Compound Comparison Using LINGO-Based Load-Balancing Strategies on Multi-GPUs.

    Science.gov (United States)

    Lin, Chun-Yuan; Wang, Chung-Hung; Hung, Che-Lun; Lin, Yu-Shiang

    2015-01-01

    Compound comparison is an important task for the computational chemistry. By the comparison results, potential inhibitors can be found and then used for the pharmacy experiments. The time complexity of a pairwise compound comparison is O(n (2)), where n is the maximal length of compounds. In general, the length of compounds is tens to hundreds, and the computation time is small. However, more and more compounds have been synthesized and extracted now, even more than tens of millions. Therefore, it still will be time-consuming when comparing with a large amount of compounds (seen as a multiple compound comparison problem, abbreviated to MCC). The intrinsic time complexity of MCC problem is O(k (2) n (2)) with k compounds of maximal length n. In this paper, we propose a GPU-based algorithm for MCC problem, called CUDA-MCC, on single- and multi-GPUs. Four LINGO-based load-balancing strategies are considered in CUDA-MCC in order to accelerate the computation speed among thread blocks on GPUs. CUDA-MCC was implemented by C+OpenMP+CUDA. CUDA-MCC achieved 45 times and 391 times faster than its CPU version on a single NVIDIA Tesla K20m GPU card and a dual-NVIDIA Tesla K20m GPU card, respectively, under the experimental results.

  2. Assessment of patients with multiple sclerosis according to tests of the Multiple Sclerosis Functional Composite

    Directory of Open Access Journals (Sweden)

    Anelise Ineu Figueiredo

    Full Text Available Abstract Introduction: The Multiple Sclerosis Functional Composite (MSFC is a scale that evaluates the functional and cognitive aspects of patients with multiple sclerosis (MS. Objective: To compare the performance of individuals with the relapsing-remitting form of MS (RRMS with a group of healthy subjects using the MSFC. Methods: Twenty subjects were investigated in this study, consisting of 10 patients with clinical diagnosis of RRMS and 10 controls with similar gender and age to the group with the disease. The three tests that comprise the MSFC were used for the evaluation of gait, upper limb motor function and cognition (memory and processing speed. Student's t-test was used to assess data with normal distribution and data with skewed distribution were evaluated using the Mann-Whitney test. Results: The results showed that the patients with RRMS took longer to perform the locomotion test (6.91 ± 2.35 compared to the control group (5.16 ± 1.28. The MS group (22.06 ± 5.44 also showed greater difficulty in performing a task with the dominant upper limb compared to the healthy subjects (17.79 ± 2.96. No statistically significant difference was found between the groups in the performance of cognitive tasks (p = .65. Conclusion: The use of the MSFC tests proved valuable for measuring possible motor and cognitive impairments in patients with RRMS. Thus, it is suggested that this scale is adopted in clinical practice, improving therapies for the treatment of MS patients and thereby providing them a better quality of life.

  3. A spreadsheet template compatible with Microsoft Excel and iWork Numbers that returns the simultaneous confidence intervals for all pairwise differences between multiple sample means.

    Science.gov (United States)

    Brown, Angus M

    2010-04-01

    The objective of the method described in this paper is to develop a spreadsheet template for the purpose of comparing multiple sample means. An initial analysis of variance (ANOVA) test on the data returns F--the test statistic. If F is larger than the critical F value drawn from the F distribution at the appropriate degrees of freedom, convention dictates rejection of the null hypothesis and allows subsequent multiple comparison testing to determine where the inequalities between the sample means lie. A variety of multiple comparison methods are described that return the 95% confidence intervals for differences between means using an inclusive pairwise comparison of the sample means. 2009 Elsevier Ireland Ltd. All rights reserved.

  4. Comparison of Intelligibility Measures for Adults with Parkinson's Disease, Adults with Multiple Sclerosis, and Healthy Controls

    Science.gov (United States)

    Stipancic, Kaila L.; Tjaden, Kris; Wilding, Gregory

    2016-01-01

    Purpose: This study obtained judgments of sentence intelligibility using orthographic transcription for comparison with previously reported intelligibility judgments obtained using a visual analog scale (VAS) for individuals with Parkinson's disease and multiple sclerosis and healthy controls (K. Tjaden, J. E. Sussman, & G. E. Wilding, 2014).…

  5. Coding in pigeons: Multiple-coding versus single-code/default strategies.

    Science.gov (United States)

    Pinto, Carlos; Machado, Armando

    2015-05-01

    To investigate the coding strategies that pigeons may use in a temporal discrimination tasks, pigeons were trained on a matching-to-sample procedure with three sample durations (2s, 6s and 18s) and two comparisons (red and green hues). One comparison was correct following 2-s samples and the other was correct following both 6-s and 18-s samples. Tests were then run to contrast the predictions of two hypotheses concerning the pigeons' coding strategies, the multiple-coding and the single-code/default. According to the multiple-coding hypothesis, three response rules are acquired, one for each sample. According to the single-code/default hypothesis, only two response rules are acquired, one for the 2-s sample and a "default" rule for any other duration. In retention interval tests, pigeons preferred the "default" key, a result predicted by the single-code/default hypothesis. In no-sample tests, pigeons preferred the key associated with the 2-s sample, a result predicted by multiple-coding. Finally, in generalization tests, when the sample duration equaled 3.5s, the geometric mean of 2s and 6s, pigeons preferred the key associated with the 6-s and 18-s samples, a result predicted by the single-code/default hypothesis. The pattern of results suggests the need for models that take into account multiple sources of stimulus control. © Society for the Experimental Analysis of Behavior.

  6. A comparison of single and multiple aliquot TT-OSL data sets for sand-sized quartz from the Arabian Peninsula

    International Nuclear Information System (INIS)

    Rosenberg, T.M.; Preusser, F.; Wintle, A.G.

    2011-01-01

    The quartz OSL signal from dune sands from Saudi Arabia and Oman start to saturate at doses of about 100 Gy. In order to try to date dune sands with greater expected doses, a previously published, single-aliquot, regenerative-dose protocol (SAR) for thermally-transferred optically stimulated luminescence (TT-OSL) was tested. Dose recovery tests, recycling and recuperation ratios showed robust functioning and dose response curves demonstrated the potential to extend the dose range to beyond 600 Gy. Multiple aliquot additive dose (MAAD) TT-OSL protocols were used to test for sensitivity changes in the SAR TT-OSL protocol up to doses of 1200 Gy. A strong dose dependent deviation of the SAR TT-OSL relative to the MAAD TT-OSL dose response is observed. Comparison of the TT-OSL and OSL sensitivity data obtained from the MAAD and SAR data sets shows a lack of proportionality between TT-OSL and OSL for the SAR data which will result in a problem when SAR dose response curves are constructed using many regeneration points with doses above 300 Gy.

  7. Comparison of the automated vision screening test to the Snellen test.

    Science.gov (United States)

    Gofin, R; Falk, M

    1991-03-01

    The comparison of an automatic vision screening machine using the Landolt rings and the usual Snellen Chart was carried out among 123 second grade and 149 fifth grade students in an elementary school in Jerusalem. The sensitivity of the test for a cut-off point of greater than or equal to 6/12 according to the Snellen test was 41.7% (CI = 16.5-71.4) and the specificity was 86.5% (CI 78.1-92.2) for second graders. For fifth graders the values were 50.0% (CI = 20.1-79.9) and 90.6% (CI 83.7-94.8) respectively. Diagnosis by a specialist decreased the number of 'false negatives' and confirmed the pathological cases. The automatic test was well accepted by the children. Though more time is needed for assessment using the automatic test, its advantage is that no professional staff are required.

  8. Multiple comparisons permutation test for image based data mining in radiotherapy

    NARCIS (Netherlands)

    Chen, Chun; Witte, Marnix; Heemsbergen, Wilma; van Herk, Marcel

    2013-01-01

    : Comparing incidental dose distributions (i.e. images) of patients with different outcomes is a straightforward way to explore dose-response hypotheses in radiotherapy. In this paper, we introduced a permutation test that compares images, such as dose distributions from radiotherapy, while tackling

  9. Inherent variation in multiple shoe-sole test impressions.

    Science.gov (United States)

    Shor, Yaron; Wiesner, Sarena; Tsach, Tsadok; Gurel, Ron; Yekutieli, Yoram

    2018-04-01

    Shoeprints left at crime scenes are seldom perfect. Many prints are distorted or contaminated by various materials. Noisy background often contributes to vagueness on the shoeprints as well. Test impressions made from the suspect's shoes in the laboratory are considered a genuine replication of the shoe-sole. This naïve attitude is far from being correct. Consecutive test impressions made in the laboratory under strict similar conditions revealed differences among the exemplars of the same sole. Some of them are minor, but some are major, and can mislead the less experienced practitioners during the comparison process. This article focuses on the inherent within source variability between controlled shoeprints made from the same shoe, as it appears on the RACs. To describe and analyze this variability, repeated test impressions were prepared, and datasets were created. Several RACs were marked on each test impression, using an expert assisting software tool (developed in the authors' lab). The variance in repeated test impressions is demonstrated and possible sources are discussed. This variance should be considered when trying to establish the degree of matching between individual characteristics. Copyright © 2017. Published by Elsevier B.V.

  10. Non-parametric comparison of histogrammed two-dimensional data distributions using the Energy Test

    International Nuclear Information System (INIS)

    Reid, Ivan D; Lopes, Raul H C; Hobson, Peter R

    2012-01-01

    When monitoring complex experiments, comparison is often made between regularly acquired histograms of data and reference histograms which represent the ideal state of the equipment. With the larger HEP experiments now ramping up, there is a need for automation of this task since the volume of comparisons could overwhelm human operators. However, the two-dimensional histogram comparison tools available in ROOT have been noted in the past to exhibit shortcomings. We discuss a newer comparison test for two-dimensional histograms, based on the Energy Test of Aslan and Zech, which provides more conclusive discrimination between histograms of data coming from different distributions than methods provided in a recent ROOT release.

  11. Rapid descriptive sensory methods – Comparison of Free Multiple Sorting, Partial Napping, Napping, Flash Profiling and conventional profiling

    DEFF Research Database (Denmark)

    Dehlholm, Christian; Brockhoff, Per B.; Meinert, Lene

    2012-01-01

    is a modal restriction of Napping to specific sensory modalities, directing sensation and still allowing a holistic approach to products. The new methods are compared to Flash Profiling, Napping and conventional descriptive sensory profiling. Evaluations are performed by several panels of expert assessors......Two new rapid descriptive sensory evaluation methods are introduced to the field of food sensory evaluation. The first method, free multiple sorting, allows subjects to perform ad libitum free sortings, until they feel that no more relevant dissimilarities among products remain. The second method...... are applied for the graphical validation and comparisons. This allows similar comparisons and is applicable to single-block evaluation designs such as Napping. The partial Napping allows repetitions on multiple sensory modalities, e.g. appearance, taste and mouthfeel, and shows the average...

  12. Accelerating Multiple Compound Comparison Using LINGO-Based Load-Balancing Strategies on Multi-GPUs

    Directory of Open Access Journals (Sweden)

    Chun-Yuan Lin

    2015-01-01

    Full Text Available Compound comparison is an important task for the computational chemistry. By the comparison results, potential inhibitors can be found and then used for the pharmacy experiments. The time complexity of a pairwise compound comparison is O(n2, where n is the maximal length of compounds. In general, the length of compounds is tens to hundreds, and the computation time is small. However, more and more compounds have been synthesized and extracted now, even more than tens of millions. Therefore, it still will be time-consuming when comparing with a large amount of compounds (seen as a multiple compound comparison problem, abbreviated to MCC. The intrinsic time complexity of MCC problem is O(k2n2 with k compounds of maximal length n. In this paper, we propose a GPU-based algorithm for MCC problem, called CUDA-MCC, on single- and multi-GPUs. Four LINGO-based load-balancing strategies are considered in CUDA-MCC in order to accelerate the computation speed among thread blocks on GPUs. CUDA-MCC was implemented by C+OpenMP+CUDA. CUDA-MCC achieved 45 times and 391 times faster than its CPU version on a single NVIDIA Tesla K20m GPU card and a dual-NVIDIA Tesla K20m GPU card, respectively, under the experimental results.

  13. Comparison between FEM and high heat flux thermal fatigue testing results of ITER divertor plasma facing mock-ups

    Energy Technology Data Exchange (ETDEWEB)

    Crescenzi, F., E-mail: fabio.crescenzi@enea.it; Roccella, S.; Visca, E.; Moriani, A.

    2014-10-15

    Highlights: • Divertor is an important part of the ITER machine. • Finite element analysis allows designers to explore multiple design options, reducing physical prototypes and optimizing design performance. • The hydraulic thermal-mechanical analysis performed by ANSYS and the test results on small-scale mock-ups manufactured by HRP were compared. • FEA results confirmed many experimental data, then it could be very useful for next design optimization. - Abstract: The divertor is one of the most challenging components of “DEMO” the next step ITER machine, so many tasks regarding modeling and experiments have been made in the past years to assess manufacturing processes, materials and thus the life-time of the components. In this context the finite element analysis (FEA) allows designers to explore multiple design options, to reduce physical prototypes and to optimize design performance. The comparison between the hydraulic thermal-mechanical analysis performed by ANSYS WORKBENCH 14.5 and the test results [1] on small-scale mock-ups manufactured with the Hot Radial Pressing (HRP) [2] technology is presented in this paper. During the thermal fatigue testing in the Efremov TSEFEY facility to assess the heat flux load-carrying capability of the mock-ups, only the surface temperature was measured, so the FEA was important because it allowed to know any other information (temperature inside the materials, local water temperature, local stress, etc.). FEA was performed coupling the thermal-hydraulic analysis, that calculated the temperature distributions on the components and the heat transfer coefficient (HTC) between water and heat sink tube, with the mechanical analysis. The comparison between analysis and testing results was based on the temperature maps of the loaded surface and on number of the cycles supported during the testing and those predicted by the mechanical analysis using the experimental fatigue curves for CuCrZr-IG, that is the structural

  14. Hidden multiplicity in exploratory multiway ANOVA: Prevalence and remedies

    NARCIS (Netherlands)

    Cramer, A.O.J.; van Ravenzwaaij, D.; Matzke, D.; Steingroever, H.; Wetzels, R.; Grasman, R.P.P.P.; Waldorp, L.J.; Wagenmakers, E.-J.

    2016-01-01

    Many psychologists do not realize that exploratory use of the popular multiway analysis of variance harbors a multiple-comparison problem. In the case of two factors, three separate null hypotheses are subject to test (i.e., two main effects and one interaction). Consequently, the probability of at

  15. Conservatism implications of shock test tailoring for multiple design environments

    Science.gov (United States)

    Baca, Thomas J.; Bell, R. Glenn; Robbins, Susan A.

    1987-01-01

    A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ranked peak acceleration data in terms of an Index of Conservation (IOC) and an Overtest Factor (OTF). The multi-environment conservation analysis addresses the issue of both absolute and average conservation. The method is demonstrated in a case where four laboratory tests have been specified to qualify a component which must survive seven different field environments. Final judgment of the tailored test specification is shown to require an understanding of the predominant failure modes of the test item.

  16. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  17. Spatial and visuospatial working memory tests predict performance in classic multiple-object tracking in young adults, but nonspatial measures of the executive do not.

    Science.gov (United States)

    Trick, Lana M; Mutreja, Rachna; Hunt, Kelly

    2012-02-01

    An individual-differences approach was used to investigate the roles of visuospatial working memory and the executive in multiple-object tracking. The Corsi Blocks and Visual Patterns Tests were used to assess visuospatial working memory. Two relatively nonspatial measures of the executive were used: operation span (OSPAN) and reading span (RSPAN). For purposes of comparison, the digit span test was also included (a measure not expected to correlate with tracking). The tests predicted substantial amounts of variance (R (2) = .33), and the visuospatial measures accounted for the majority (R (2) = .30), with each making a significant contribution. Although the executive measures correlated with each other, the RSPAN did not correlate with tracking. The correlation between OSPAN and tracking was similar in magnitude to that between digit span and tracking (p < .05 for both), and when regression was used to partial out shared variance between the two tests, the remaining variance predicted by the OSPAN was minimal (sr ( 2 ) = .029). When measures of spatial memory were included in the regression, the unique variance predicted by the OSPAN became negligible (sr ( 2 ) = .000004). This suggests that the executive, as measured by tests such as the OSPAN, plays little role in explaining individual differences in multiple-object tracking.

  18. Reanalysis comparisons of upper tropospheric-lower stratospheric jets and multiple tropopauses

    Science.gov (United States)

    Manney, Gloria L.; Hegglin, Michaela I.; Lawrence, Zachary D.; Wargan, Krzysztof; Millán, Luis F.; Schwartz, Michael J.; Santee, Michelle L.; Lambert, Alyn; Pawson, Steven; Knosp, Brian W.; Fuller, Ryan A.; Daffer, William H.

    2017-09-01

    The representation of upper tropospheric-lower stratospheric (UTLS) jet and tropopause characteristics is compared in five modern high-resolution reanalyses for 1980 through 2014. Climatologies of upper tropospheric jet, subvortex jet (the lowermost part of the stratospheric vortex), and multiple tropopause frequency distributions in MERRA (Modern-Era Retrospective analysis for Research and Applications), ERA-I (ERA-Interim; the European Centre for Medium-Range Weather Forecasts, ECMWF, interim reanalysis), JRA-55 (the Japanese 55-year Reanalysis), and CFSR (the Climate Forecast System Reanalysis) are compared with those in MERRA-2. Differences between alternate products from individual reanalysis systems are assessed; in particular, a comparison of CFSR data on model and pressure levels highlights the importance of vertical grid spacing. Most of the differences in distributions of UTLS jets and multiple tropopauses are consistent with the differences in assimilation model grids and resolution - for example, ERA-I (with coarsest native horizontal resolution) typically shows a significant low bias in upper tropospheric jets with respect to MERRA-2, and JRA-55 (the Japanese 55-year Reanalysis) a more modest one, while CFSR (with finest native horizontal resolution) shows a high bias with respect to MERRA-2 in both upper tropospheric jets and multiple tropopauses. Vertical temperature structure and grid spacing are especially important for multiple tropopause characterizations. Substantial differences between MERRA and MERRA-2 are seen in mid- to high-latitude Southern Hemisphere (SH) winter upper tropospheric jets and multiple tropopauses as well as in the upper tropospheric jets associated with tropical circulations during the solstice seasons; some of the largest differences from the other reanalyses are seen in the same times and places. Very good qualitative agreement among the reanalyses is seen between the large-scale climatological features in UTLS jet and

  19. Westinghouse-Gothic comparisons with passive containment cooling tests using a one-to-ten-scale test facility

    International Nuclear Information System (INIS)

    Kennedy, M.D.; Woodcock, J.; Wright, R.F.; Gresham, J.A.

    1996-01-01

    The Heavy Water Reactor Facility is equipped with a passive cooling system to provide long-term decay heat removal during postulated beyond-design-basis accidents. The passive containment cooling system (PCCS) consists of an annular space between the steel containment vessel and the concrete shield building and optimized inlet and chimney designs. The design, analysis, and regulatory acceptance of a plant with PCCS requires an understanding of the external convective and radiative heat transfer phenomena, as well as the internal distributions of noncondensable gases. The internal distribution of noncondensable gases has a strong effect on the resistance to condensation heat transfer and therefore affects the wall temperature distribution applied to the external channel. To evaluate these phenomena, a test facility having a scale of approximately one to ten, known as the large-scale test, was constructed, and several series of tests were performed. Test results have been used to validate the Westinghouse-GOTHIC (WGOTHIC) computer code. A comparison of WGOTHIC predictions and test results has been completed. This paper shows that mixed-convection models applied to the interior and exterior surfaces as well as a heat and mass transfer analogy for internal condensation provides good comparison to test results. An axial distribution of noncondensables within the test vessel is also predicted

  20. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs in...

  1. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs...

  2. Simultaneous small-sample comparisons in longitudinal or multi-endpoint trials using multiple marginal models

    DEFF Research Database (Denmark)

    Pallmann, Philip; Ritz, Christian; Hothorn, Ludwig A

    2018-01-01

    , however only asymptotically. In this paper, we show how to make the approach also applicable to small-sample data problems. Specifically, we discuss the computation of adjusted P values and simultaneous confidence bounds for comparisons of randomised treatment groups as well as for levels......Simultaneous inference in longitudinal, repeated-measures, and multi-endpoint designs can be onerous, especially when trying to find a reasonable joint model from which the interesting effects and covariances are estimated. A novel statistical approach known as multiple marginal models greatly...... simplifies the modelling process: the core idea is to "marginalise" the problem and fit multiple small models to different portions of the data, and then estimate the overall covariance matrix in a subsequent, separate step. Using these estimates guarantees strong control of the family-wise error rate...

  3. The optimal hormonal replacement modality selection for multiple organ procurement from brain-dead organ donors

    Directory of Open Access Journals (Sweden)

    Mi Z

    2014-12-01

    Full Text Available Zhibao Mi,1 Dimitri Novitzky,2 Joseph F Collins,1 David KC Cooper3 1Cooperative Studies Program Coordinating Center, VA Maryland Health Care Systems, Perry Point, MD, USA; 2Department of Cardiothoracic Surgery, University of South Florida, Tampa, FL, USA; 3Thomas E Starzl Transplantation Institute, University of Pittsburgh, Pittsburgh, PA, USA Abstract: The management of brain-dead organ donors is complex. The use of inotropic agents and replacement of depleted hormones (hormonal replacement therapy is crucial for successful multiple organ procurement, yet the optimal hormonal replacement has not been identified, and the statistical adjustment to determine the best selection is not trivial. Traditional pair-wise comparisons between every pair of treatments, and multiple comparisons to all (MCA, are statistically conservative. Hsu’s multiple comparisons with the best (MCB – adapted from the Dunnett’s multiple comparisons with control (MCC – has been used for selecting the best treatment based on continuous variables. We selected the best hormonal replacement modality for successful multiple organ procurement using a two-step approach. First, we estimated the predicted margins by constructing generalized linear models (GLM or generalized linear mixed models (GLMM, and then we applied the multiple comparison methods to identify the best hormonal replacement modality given that the testing of hormonal replacement modalities is independent. Based on 10-year data from the United Network for Organ Sharing (UNOS, among 16 hormonal replacement modalities, and using the 95% simultaneous confidence intervals, we found that the combination of thyroid hormone, a corticosteroid, antidiuretic hormone, and insulin was the best modality for multiple organ procurement for transplantation. Keywords: best treatment selection, brain-dead organ donors, hormonal replacement, multiple binary endpoints, organ procurement, multiple comparisons

  4. PCA-based bootstrap confidence interval tests for gene-disease association involving multiple SNPs

    Directory of Open Access Journals (Sweden)

    Xue Fuzhong

    2010-01-01

    Full Text Available Abstract Background Genetic association study is currently the primary vehicle for identification and characterization of disease-predisposing variant(s which usually involves multiple single-nucleotide polymorphisms (SNPs available. However, SNP-wise association tests raise concerns over multiple testing. Haplotype-based methods have the advantage of being able to account for correlations between neighbouring SNPs, yet assuming Hardy-Weinberg equilibrium (HWE and potentially large number degrees of freedom can harm its statistical power and robustness. Approaches based on principal component analysis (PCA are preferable in this regard but their performance varies with methods of extracting principal components (PCs. Results PCA-based bootstrap confidence interval test (PCA-BCIT, which directly uses the PC scores to assess gene-disease association, was developed and evaluated for three ways of extracting PCs, i.e., cases only(CAES, controls only(COES and cases and controls combined(CES. Extraction of PCs with COES is preferred to that with CAES and CES. Performance of the test was examined via simulations as well as analyses on data of rheumatoid arthritis and heroin addiction, which maintains nominal level under null hypothesis and showed comparable performance with permutation test. Conclusions PCA-BCIT is a valid and powerful method for assessing gene-disease association involving multiple SNPs.

  5. ODMSummary: A Tool for Automatic Structured Comparison of Multiple Medical Forms Based on Semantic Annotation with the Unified Medical Language System.

    Science.gov (United States)

    Storck, Michael; Krumm, Rainer; Dugas, Martin

    2016-01-01

    Medical documentation is applied in various settings including patient care and clinical research. Since procedures of medical documentation are heterogeneous and developed further, secondary use of medical data is complicated. Development of medical forms, merging of data from different sources and meta-analyses of different data sets are currently a predominantly manual process and therefore difficult and cumbersome. Available applications to automate these processes are limited. In particular, tools to compare multiple documentation forms are missing. The objective of this work is to design, implement and evaluate the new system ODMSummary for comparison of multiple forms with a high number of semantically annotated data elements and a high level of usability. System requirements are the capability to summarize and compare a set of forms, enable to estimate the documentation effort, track changes in different versions of forms and find comparable items in different forms. Forms are provided in Operational Data Model format with semantic annotations from the Unified Medical Language System. 12 medical experts were invited to participate in a 3-phase evaluation of the tool regarding usability. ODMSummary (available at https://odmtoolbox.uni-muenster.de/summary/summary.html) provides a structured overview of multiple forms and their documentation fields. This comparison enables medical experts to assess multiple forms or whole datasets for secondary use. System usability was optimized based on expert feedback. The evaluation demonstrates that feedback from domain experts is needed to identify usability issues. In conclusion, this work shows that automatic comparison of multiple forms is feasible and the results are usable for medical experts.

  6. Integrative set enrichment testing for multiple omics platforms

    Directory of Open Access Journals (Sweden)

    Poisson Laila M

    2011-11-01

    Full Text Available Abstract Background Enrichment testing assesses the overall evidence of differential expression behavior of the elements within a defined set. When we have measured many molecular aspects, e.g. gene expression, metabolites, proteins, it is desirable to assess their differential tendencies jointly across platforms using an integrated set enrichment test. In this work we explore the properties of several methods for performing a combined enrichment test using gene expression and metabolomics as the motivating platforms. Results Using two simulation models we explored the properties of several enrichment methods including two novel methods: the logistic regression 2-degree of freedom Wald test and the 2-dimensional permutation p-value for the sum-of-squared statistics test. In relation to their univariate counterparts we find that the joint tests can improve our ability to detect results that are marginal univariately. We also find that joint tests improve the ranking of associated pathways compared to their univariate counterparts. However, there is a risk of Type I error inflation with some methods and self-contained methods lose specificity when the sets are not representative of underlying association. Conclusions In this work we show that consideration of data from multiple platforms, in conjunction with summarization via a priori pathway information, leads to increased power in detection of genomic associations with phenotypes.

  7. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    Science.gov (United States)

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  8. A P-value model for theoretical power analysis and its applications in multiple testing procedures

    Directory of Open Access Journals (Sweden)

    Fengqing Zhang

    2016-10-01

    Full Text Available Abstract Background Power analysis is a critical aspect of the design of experiments to detect an effect of a given size. When multiple hypotheses are tested simultaneously, multiplicity adjustments to p-values should be taken into account in power analysis. There are a limited number of studies on power analysis in multiple testing procedures. For some methods, the theoretical analysis is difficult and extensive numerical simulations are often needed, while other methods oversimplify the information under the alternative hypothesis. To this end, this paper aims to develop a new statistical model for power analysis in multiple testing procedures. Methods We propose a step-function-based p-value model under the alternative hypothesis, which is simple enough to perform power analysis without simulations, but not too simple to lose the information from the alternative hypothesis. The first step is to transform distributions of different test statistics (e.g., t, chi-square or F to distributions of corresponding p-values. We then use a step function to approximate each of the p-value’s distributions by matching the mean and variance. Lastly, the step-function-based p-value model can be used for theoretical power analysis. Results The proposed model is applied to problems in multiple testing procedures. We first show how the most powerful critical constants can be chosen using the step-function-based p-value model. Our model is then applied to the field of multiple testing procedures to explain the assumption of monotonicity of the critical constants. Lastly, we apply our model to a behavioral weight loss and maintenance study to select the optimal critical constants. Conclusions The proposed model is easy to implement and preserves the information from the alternative hypothesis.

  9. Multiple linear combination (MLC) regression tests for common variants adapted to linkage disequilibrium structure.

    Science.gov (United States)

    Yoo, Yun Joo; Sun, Lei; Poirier, Julia G; Paterson, Andrew D; Bull, Shelley B

    2017-02-01

    By jointly analyzing multiple variants within a gene, instead of one at a time, gene-based multiple regression can improve power, robustness, and interpretation in genetic association analysis. We investigate multiple linear combination (MLC) test statistics for analysis of common variants under realistic trait models with linkage disequilibrium (LD) based on HapMap Asian haplotypes. MLC is a directional test that exploits LD structure in a gene to construct clusters of closely correlated variants recoded such that the majority of pairwise correlations are positive. It combines variant effects within the same cluster linearly, and aggregates cluster-specific effects in a quadratic sum of squares and cross-products, producing a test statistic with reduced degrees of freedom (df) equal to the number of clusters. By simulation studies of 1000 genes from across the genome, we demonstrate that MLC is a well-powered and robust choice among existing methods across a broad range of gene structures. Compared to minimum P-value, variance-component, and principal-component methods, the mean power of MLC is never much lower than that of other methods, and can be higher, particularly with multiple causal variants. Moreover, the variation in gene-specific MLC test size and power across 1000 genes is less than that of other methods, suggesting it is a complementary approach for discovery in genome-wide analysis. The cluster construction of the MLC test statistics helps reveal within-gene LD structure, allowing interpretation of clustered variants as haplotypic effects, while multiple regression helps to distinguish direct and indirect associations. © 2016 The Authors Genetic Epidemiology Published by Wiley Periodicals, Inc.

  10. Effects of dependence in high-dimensional multiple testing problems

    Directory of Open Access Journals (Sweden)

    van de Wiel Mark A

    2008-02-01

    Full Text Available Abstract Background We consider effects of dependence among variables of high-dimensional data in multiple hypothesis testing problems, in particular the False Discovery Rate (FDR control procedures. Recent simulation studies consider only simple correlation structures among variables, which is hardly inspired by real data features. Our aim is to systematically study effects of several network features like sparsity and correlation strength by imposing dependence structures among variables using random correlation matrices. Results We study the robustness against dependence of several FDR procedures that are popular in microarray studies, such as Benjamin-Hochberg FDR, Storey's q-value, SAM and resampling based FDR procedures. False Non-discovery Rates and estimates of the number of null hypotheses are computed from those methods and compared. Our simulation study shows that methods such as SAM and the q-value do not adequately control the FDR to the level claimed under dependence conditions. On the other hand, the adaptive Benjamini-Hochberg procedure seems to be most robust while remaining conservative. Finally, the estimates of the number of true null hypotheses under various dependence conditions are variable. Conclusion We discuss a new method for efficient guided simulation of dependent data, which satisfy imposed network constraints as conditional independence structures. Our simulation set-up allows for a structural study of the effect of dependencies on multiple testing criterions and is useful for testing a potentially new method on π0 or FDR estimation in a dependency context.

  11. Comparisons of ROSA-III and FIST BWR loss of coolant accident simulation tests

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Suzuki, Mitsuhiro; Koizumi, Yasuo

    1985-10-01

    A common understanding and interpretation of BWR system response and the controlling phenomena in LOCA transients has been achieved through the evaluation and comparison of counterpart tests performed in the ROSA-III and FIST test facilities. These facilities, which are designed to simulate the thermal-hydraulic response of BWR systems, are operated respectively by the Japan Atomic Energy Research Institute (JAERI) and the General Electric Company. Comparison is made between three types of counterpart tests, each performed under similar tests conditions in the two facilities. They are large break, small break, and steamline break LOCA's. The system responses to these tests in each facility are quite similar. The sequence of events are similar, and the timing of these events are similar. Differences that do occur are due to minor differences in modeling objectives, facility scaling, and test conditions. Parallel channel flow interactions effects in the ROSA-III four channel (half length) core, although noticeable in the large break test, do not result in major differences with the single channel response in FIST. In the small break tests the timing of events is offset by the earlier ADS actuation in FIST. The steamline test responses are similar except there is no heatup in FIST, resulting from a different ECCS trip modeling. Overall comparisons between ROSA-III and FIST system responses in LOCA tests is very good. (author)

  12. Operation of a nuclear test gage at low multiplications

    International Nuclear Information System (INIS)

    Baumann, N.P.

    1977-01-01

    The Nuclear Test Gage (NTG) at the Savannah River Plant is a subcritical multiplying facility (low k) with H 2 O moderator and 2.54-cm-diameter fuel slugs of 5 wt percent 235 U in aluminum alloy at a 4.285-cm triangular pitch. The core of the facility is 61-cm long with a normal diameter of 27 cm. The NTG is used for quality control of reactor components, such as 235 U-Al fuel tubes, Li--Al target tubes, control and safety rods, and miscellaneous special irradiation elements. A component is tested by passing it through an axial test port 11.63 cm in diameter. The ion chamber response from the resultant change in neutron source multiplication is then compared with corresponding responses from known standards

  13. Valx: A System for Extracting and Structuring Numeric Lab Test Comparison Statements from Text.

    Science.gov (United States)

    Hao, Tianyong; Liu, Hongfang; Weng, Chunhua

    2016-05-17

    To develop an automated method for extracting and structuring numeric lab test comparison statements from text and evaluate the method using clinical trial eligibility criteria text. Leveraging semantic knowledge from the Unified Medical Language System (UMLS) and domain knowledge acquired from the Internet, Valx takes seven steps to extract and normalize numeric lab test expressions: 1) text preprocessing, 2) numeric, unit, and comparison operator extraction, 3) variable identification using hybrid knowledge, 4) variable - numeric association, 5) context-based association filtering, 6) measurement unit normalization, and 7) heuristic rule-based comparison statements verification. Our reference standard was the consensus-based annotation among three raters for all comparison statements for two variables, i.e., HbA1c and glucose, identified from all of Type 1 and Type 2 diabetes trials in ClinicalTrials.gov. The precision, recall, and F-measure for structuring HbA1c comparison statements were 99.6%, 98.1%, 98.8% for Type 1 diabetes trials, and 98.8%, 96.9%, 97.8% for Type 2 diabetes trials, respectively. The precision, recall, and F-measure for structuring glucose comparison statements were 97.3%, 94.8%, 96.1% for Type 1 diabetes trials, and 92.3%, 92.3%, 92.3% for Type 2 diabetes trials, respectively. Valx is effective at extracting and structuring free-text lab test comparison statements in clinical trial summaries. Future studies are warranted to test its generalizability beyond eligibility criteria text. The open-source Valx enables its further evaluation and continued improvement among the collaborative scientific community.

  14. Reliability of psychophysiological responses across multiple motion sickness stimulation tests

    Science.gov (United States)

    Stout, C. S.; Toscano, W. B.; Cowings, P. S.

    1995-01-01

    Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

  15. Relationship between contrast sensitivity test and disease severity in multiple sclerosis patients.

    Science.gov (United States)

    Soler García, A; González Gómez, A; Figueroa-Ortiz, L C; García-Ben, A; García-Campos, J

    2014-09-01

    To assess the importance of the Pelli-Robson contrast sensitivity test in multiple sclerosis patients according to the Expanded Disability Status Scale (EDSS). A total of 62 patients with multiple sclerosis were included in a retrospective study. Patients were enrolled from the Neurology Department to Neuroophthalmology at Virgen de la Victoria Hospital. Patients were classified into 3 groups according to EDSS: group A) lower than 1.5, group B) between 1.5 and 3.5 and group C) greater than 3.5. Visual acuity and monocular and binocular contrast sensitivity were performed with Snellen and Pelli-Robson tests respectively. Twelve disease-free control participants were also recruited. Correlations between parameter changes were analyzed. The mean duration of the disease was 81.54±35.32 months. Monocular and binocular Pelli-Robson mean values in the control group were 1.82±0.10 and 1.93±0.43 respectively, and 1.61±0.29 and 1.83±0.19 in multiple sclerosis patients. There were statistically significant differences in the monocular analysis for a level of significance P<.05. Mean monocular and binocular Pelli-Robson values in relation to gravity level were, in group A: 1.66±0.24 and 1.90±0.98, group B: 1.64±0.21 and 1.82±0.16, and group C: 1.47±0.45 and 1.73±0.32 respectively. Group differences were statistically significant in both tests: P=.05 and P=.027. Monocular and binocular contrast discrimination analyzed using the Pelli-Robson test was found to be significantly lower when the severity level, according EDSS, increases in multiple sclerosis patients. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  16. 20 Years of standard patch testing in an eczema population with focus on patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2007-01-01

    Results of standard patch tests performed with the same methodology in one centre are rarely available over a large time span. This gives the unique opportunity to study not only prevalence but also persistency of contact allergy and characterize subpopulations. The objectives were to investigate...... sensitivity rates and persistencies of patch test results and characterize patients with multiple contact allergies. A 20-year retrospective database-based study of 14 998 patients patch tested with the European Standard Series was performed. 34.5% were sensitized, primarily women. Sensitivity to nickel......(Me)isothiazolinone, and primin and poor for paraben mix. 5.1% were multiple allergic, primarily women, and 90% got diagnosed by the first test. Frequency of multiple allergies increased with age. More multiple- than mono/double-allergic patients were tested multiple times. Persistency and sensitivity rates in a Danish eczema...

  17. Final comparison report on ISP-35: Nupec hydrogen mixing and distribution test (Test M-7-1)

    International Nuclear Information System (INIS)

    1994-12-01

    This final comparison report summarizes the results of the OECD/CSNI sponsored ISP-35 exercise which was based on NUPEC's Hydrogen Mixing and Distribution Test M-7-1. 12 organizations from 10 different countries took part in the exercise. For the ISP-35 test, a steam/light gas (helium) mixture was released into the lower region of a simplified model of a PWR containment. At the same time, the dome cooling spray was also activated. the transient time histories for gas temperature and concentrations were recorded for each of the 25 compartments of the model containment. The wall temperatures as well as the dome pressure were also recorded. The ISP-35 participants simulated the test conditions and attempted to predict the time histories using their accident analysis codes. Results of these analyses are presented, and comparisons are made between the experimental data and the calculated data. In general, predictions for pressure, helium concentration and gas distribution patterns were achieved with acceptable accuracy

  18. Application of range-test in multiple linear regression analysis in ...

    African Journals Online (AJOL)

    Application of range-test in multiple linear regression analysis in the presence of outliers is studied in this paper. First, the plot of the explanatory variables (i.e. Administration, Social/Commercial, Economic services and Transfer) on the dependent variable (i.e. GDP) was done to identify the statistical trend over the years.

  19. WTA estimates using the method of paired comparison: tests of robustness

    Science.gov (United States)

    Patricia A. Champ; John B. Loomis

    1998-01-01

    The method of paired comparison is modified to allow choices between two alternative gains so as to estimate willingness to accept (WTA) without loss aversion. The robustness of WTA values for two public goods is tested with respect to sensitivity of theWTA measure to the context of the bundle of goods used in the paired comparison exercise and to the scope (scale) of...

  20. Pretest aerosol code comparisons for LWR aerosol containment tests LA1 and LA2

    International Nuclear Information System (INIS)

    Wright, A.L.; Wilson, J.H.; Arwood, P.C.

    1986-01-01

    The Light-Water-Reactor (LWR) Aerosol Containment Experiments (LACE) are being performed in Richland, Washington, at the Hanford Engineering Development Laboratory (HEDL) under the leadership of an international project board and the Electric Power Research Institute. These tests have two objectives: (1) to investigate, at large scale, the inherent aerosol retention behavior in LWR containments under simulated severe accident conditions, and (2) to provide an experimental data base for validating aerosol behavior and thermal-hydraulic computer codes. Aerosol computer-code comparison activities are being coordinated at the Oak Ridge National Laboratory. For each of the six LACE tests, ''pretest'' calculations (for code-to-code comparisons) and ''posttest'' calculations (for code-to-test data comparisons) are being performed. The overall goals of the comparison effort are (1) to provide code users with experience in applying their codes to LWR accident-sequence conditions and (2) to evaluate and improve the code models

  1. Factors influencing behavioral intention to undergo Papanicolaou testing in early adulthood: Comparison of Japanese and Korean women.

    Science.gov (United States)

    Kang, Kyung-Ah; Kim, Shin-Jeong; Kaneko, Noriyo

    2017-12-01

    In this study, we identified the factors influencing behavioral intention to undergo Papanicolaou testing among Japanese and Korean women in early adulthood. Their behavioral intentions were compared in this cross-sectional descriptive study. In total, 887 women (Japanese = 498, Korean = 389) aged 20-39 years participated in this study. Using a self-report questionnaire, knowledge, attitudes, subjective norm, perceived behavioral control, and behavioral intention were surveyed. There were significant differences between Japanese and Korean women's scores on all main variables. For Japanese women, all the variables moderately correlated with behavioral intention. In comparison, for Korean women, all independent variables, except for knowledge, moderately correlated with behavioral intention. Through a multiple regression analysis, age, undergoing Papanicolaou testing, attitudes, subjective norm, and perceived behavioral control were identified as significant predictors of behavioral intention among Japanese women. Among Korean women, job status, undergoing a Papanicolaou test, attitudes, subjective norm, and perceived behavioral control were demonstrated as significant predictors of behavioral intention. Health professionals should consider these factors to encourage Papanicolaou testing in women in early adulthood. © 2017 John Wiley & Sons Australia, Ltd.

  2. Comparison of sensitivity of magnetic resonance imaging and evoked potentials in the detection of brainstem involvement in multiple sclerosis

    International Nuclear Information System (INIS)

    Comi, G.; Martinelli, V.; Medaglini, S.; Locatelli, T.; Magnani, G.; Poggi, A.; Triulzi, F.

    1988-01-01

    A comparison was made of the sensitivity of magnetic resonance imaging and the combined use of Brainstem Auditory Evoked Potential and Median Somatosensory Evoked Potential in the detection of brainstem dysfunction in 54 multiple sclerosis patients. 10 refs.; 2 tabs

  3. An alcohol withdrawal test battery measuring multiple behavioral symptoms in mice.

    Science.gov (United States)

    Metten, Pamela; Schlumbohm, Jason P; Huang, Lawrence C; Greenberg, Gian D; Hack, Wyatt R; Spence, Stephanie E; Crabbe, John C

    2018-05-01

    Despite acceptance that risk for alcohol-use disorder (AUD) has a large genetic component, the identification of genes underlying various components of risk for AUD has been hampered in humans, in part by the heterogeneity of expression of the phenotype. One aspect of AUD is physical dependence. Alcohol withdrawal is a serious consequence of alcohol dependence with multiple symptoms, many of which are seen in multiple species, and can be experienced over a wide-ranging time course. In the present three studies, we developed a battery of withdrawal tests in mice, examining behavioral symptoms from multiple domains that could be measured over time. To permit eventual use of the battery in different strains of mice, we used male and female mice of a genetically heterogeneous stock developed from intercrossing eight inbred strains. Withdrawal symptoms were assessed using commonly used tests after administration of ethanol in vapor for 72 continuous hours. We found significant effects of ethanol withdrawal versus air-breathing controls on nearly all symptoms, spanning 4 days following ethanol vapor inhalation. Withdrawal produced hypothermia, greater neurohyperexcitability (seizures and tremor), anxiety-like behaviors using an apparatus (such as reduced transitions between light and dark compartments), anhedonia (reduced sucrose preference), Straub tail, backward walking, and reductions in activity; however, there were no changes in thermal pain sensitivity, hyper-reactivity to handling, or anxiety-like emergence behaviors in other apparatus. Using these data, we constructed a refined battery of withdrawal tests. Individual differences in severity of withdrawal among different tests were weakly correlated at best. This battery should be useful for identifying genetic influences on particular withdrawal behaviors, which should reflect the influences of different constellations of genes. Published by Elsevier Inc.

  4. Comparison of Shock Response Spectrum for Different Gun Tests

    Directory of Open Access Journals (Sweden)

    J.A. Cordes

    2013-01-01

    Full Text Available The Soft Catch Gun at Picatinny Arsenal is regularly used for component testing. Most shots contain accelerometers which record accelerations as a function of time. Statistics of accelerometer data indicate that the muzzle exit accelerations are, on average, higher than tactical firings. For that reason, Soft Catch Gun tests with unusually high accelerations may not be scored for Lot Acceptance Tests (LAT by some customers. The 95/50 Normal Tolerance Limit (NTL is proposed as a means of determining which test results should be scored. This paper presents comparisons of Shock Response Spectra (SRS used for the 95/50 scoring criteria. The paper also provides a Discussion Section outlining some concerns with scoring LAT results based on test results outside of the proposed 95/50 criteria.

  5. Personality Testing in Antarctic Expeditioners: Cross Cultural Comparisons and Evidence for Generalizability

    Science.gov (United States)

    Musson, D. M.; Sandal, G. M.; Harper, M. L.; Helmreich, R. L.

    Antarctica provides an ideal environment in which to study human behaviour under conditions of isolation and confinement. Such research is currently being conducted through several national Antarctic research programs, with the subject pool for these investigations necessarily consisting of individuals from multiple nationalities. Cross-cultural research has shown, however, that psychological traits and individual values may vary significantly between national and ethnic groups. Until now, there has been an implicit assumption that Antarctic personnel are essentially similar from one national program to another and that therefore findings from any one nation's Antarctic program should generalize to another, as well as to other domains such as spaceflight. We believe that it is necessary to validate this assumption through empirical research. This objective of this analysis was to determine the degree of similarity between the psychological testing profiles of Antarctic research personnel from different national Antarctic programs, and to determine the degrees of similarity or difference of these personnel to a normative population. METHODS In separate studies, Antarctic personnel from Australia (n=57), Norway (=37), and Great Britain (n=145) were administered the Personal Characteristics Inventory (PCI) before departing to Antarctica. The PCI is a battery consisting of 11 psychological scales designed to assess specific traits related to achievement and interpersonal competence that have been shown to be particularly salient to human performance under stressful and complex conditions. For comparative normative data, a group of 441 U.S. undergraduate students were also administered the PCI. Due to historical reasons, researchers in this study used 2 versions of the PCI, and only 9 of the 11 scales were directly equivalent. RESULTS For the three national Antarctic groups (Australia, Norway, and Great Britain), no significant variation was found between group mean

  6. International Test Comparisons: Reviewing Translation Error in Different Source Language-Target Language Combinations

    Science.gov (United States)

    Zhao, Xueyu; Solano-Flores, Guillermo; Qian, Ming

    2018-01-01

    This article addresses test translation review in international test comparisons. We investigated the applicability of the theory of test translation error--a theory of the multidimensionality and inevitability of test translation error--across source language-target language combinations in the translation of PISA (Programme of International…

  7. CCD Photometry Using Multiple Comparison Stars

    Directory of Open Access Journals (Sweden)

    Yonggi Kim

    2004-09-01

    Full Text Available The accuracy of CCD observations obtained at the Korean 1.8 m telescope has been studied. Seventeen comparison stars in the vicinity of the cataclysmic variable BG CMi have been measured. The ``artificial" star has been used instead of the ``control" star, what made possible to increase accuracy estimates by a factor of 1.3-2.1 times for ``good" and ``cloudy" nights, respectively. The algorithm of iterative determination of accuracy and weights of few comparison stars contributing to the artificial star, has been presented. The accuracy estimates for 13-mag stars are around 0.002 m mag for exposure times of 30 sec.

  8. Post-Graduate Student Performance in "Supervised In-Class" vs. "Unsupervised Online" Multiple Choice Tests: Implications for Cheating and Test Security

    Science.gov (United States)

    Ladyshewsky, Richard K.

    2015-01-01

    This research explores differences in multiple choice test (MCT) scores in a cohort of post-graduate students enrolled in a management and leadership course. A total of 250 students completed the MCT in either a supervised in-class paper and pencil test or an unsupervised online test. The only statistically significant difference between the nine…

  9. Memory and other properties of multiple test procedures generated by entangled graphs.

    Science.gov (United States)

    Maurer, Willi; Bretz, Frank

    2013-05-10

    Methods for addressing multiplicity in clinical trials have attracted much attention during the past 20 years. They include the investigation of new classes of multiple test procedures, such as fixed sequence, fallback and gatekeeping procedures. More recently, sequentially rejective graphical test procedures have been introduced to construct and visualize complex multiple test strategies. These methods propagate the local significance level of a rejected null hypothesis to not-yet rejected hypotheses. In the graph defining the test procedure, hypotheses together with their local significance levels are represented by weighted vertices and the propagation rule by weighted directed edges. An algorithm provides the rules for updating the local significance levels and the transition weights after rejecting an individual hypothesis. These graphical procedures have no memory in the sense that the origin of the propagated significance level is ignored in subsequent iterations. However, in some clinical trial applications, memory is desirable to reflect the underlying dependence structure of the study objectives. In such cases, it would allow the further propagation of significance levels to be dependent on their origin and thus reflect the grouped parent-descendant structures of the hypotheses. We will give examples of such situations and show how to induce memory and other properties by convex combination of several individual graphs. The resulting entangled graphs provide an intuitive way to represent the underlying relative importance relationships between the hypotheses, are as easy to perform as the original individual graphs, remain sequentially rejective and control the familywise error rate in the strong sense. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    Science.gov (United States)

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  11. Comparison between the Lactation Model and the Test-Day Model ...

    African Journals Online (AJOL)

    ARC-IRENE

    National Genetic Evaluation, using a Fixed Regression Test-day Model (TDM). This comparison is made for. Ayrshire, Guernsey, Holstein and Jersey cows participating in the South African Dairy Animal Improvement. Scheme. Specific differences between the two models were documented, with differences in statistical.

  12. Published GMO studies find no evidence of harm when corrected for multiple comparisons.

    Science.gov (United States)

    Panchin, Alexander Y; Tuzhikov, Alexander I

    2017-03-01

    A number of widely debated research articles claiming possible technology-related health concerns have influenced the public opinion on genetically modified food safety. We performed a statistical reanalysis and review of experimental data presented in some of these studies and found that quite often in contradiction with the authors' conclusions the data actually provides weak evidence of harm that cannot be differentiated from chance. In our opinion the problem of statistically unaccounted multiple comparisons has led to some of the most cited anti-genetically modified organism health claims in history. We hope this analysis puts the original results of these studies into proper context.

  13. Secure equality and greater-than tests with sublinear online complexity

    DEFF Research Database (Denmark)

    Lipmaa, Helger; Toft, Tomas

    2013-01-01

    Secure multiparty computation (MPC) allows multiple parties to evaluate functions without disclosing the private inputs. Secure comparisons (testing equality and greater-than) are important primitives required by many MPC applications. We propose two equality tests for ℓ-bit values with O(1) online...

  14. Planned Hypothesis Tests Are Not Necessarily Exempt From Multiplicity Adjustment

    Directory of Open Access Journals (Sweden)

    Andrew V. Frane

    2015-10-01

    Full Text Available Scientific research often involves testing more than one hypothesis at a time, which can inflate the probability that a Type I error (false discovery will occur. To prevent this Type I error inflation, adjustments can be made to the testing procedure that compensate for the number of tests. Yet many researchers believe that such adjustments are inherently unnecessary if the tests were “planned” (i.e., if the hypotheses were specified before the study began. This longstanding misconception continues to be perpetuated in textbooks and continues to be cited in journal articles to justify disregard for Type I error inflation. I critically evaluate this myth and examine its rationales and variations. To emphasize the myth’s prevalence and relevance in current research practice, I provide examples from popular textbooks and from recent literature. I also make recommendations for improving research practice and pedagogy regarding this problem and regarding multiple testing in general.

  15. Comparison of organic emissions from laboratory and full-scale thermal degradation of sewage sludge

    International Nuclear Information System (INIS)

    Tirey, D.A.; Striebich, R.C.; Dellinger, B.; Bostian, H.E.

    1991-01-01

    Samples of sewage sludge burned at one fluidized-bed and three multiple-hearth incinerators were subjected to laboratory flow reactor thermal decomposition testing in both pyrolytic and oxidative atmospheres. The time/temperature conditions of the laboratory testing were established to simulate as closely as possible full-scale incineration conditions so that a direct comparison of results could be made. The laboratory test results indicated that biomass decomposition products, not toxic industrial contaminants, comprised the majority of the emissions. Benzene, toluene, ethylbenzene, acrylonitrile, and acetonitrile were consistently the most environmentally significant products of thermal degradation. Comparison of the results from this study with those obtained in field tests was complicated by an apparent loss of volatile chlorocarbons from the sludge samples received for laboratory testing. However, qualitative comparison of emission factors derived from lab and field results for those compounds observed in both studies, showed reasonably good correlation for the pyrolysis testing. Results suggested that the upper stages of multiple-hearth units may vaporize many volatile components of the sludge before they enter the combustion stages of the incinerator and thus represent a direct source of introduction of pollutants into the atmosphere

  16. Evaluation of MIMIC-Model Methods for DIF Testing with Comparison to Two-Group Analysis

    Science.gov (United States)

    Woods, Carol M.

    2009-01-01

    Differential item functioning (DIF) occurs when an item on a test or questionnaire has different measurement properties for 1 group of people versus another, irrespective of mean differences on the construct. This study focuses on the use of multiple-indicator multiple-cause (MIMIC) structural equation models for DIF testing, parameterized as item…

  17. Training in multiple breath washout testing for respiratory physiotherapists.

    Science.gov (United States)

    O'Neill, Katherine; Elborn, J Stuart; Tunney, Michael M; O'Neill, Philip; Rowan, Stephen; Martin, Susan; Bradley, Judy M

    2018-03-01

    The development of multiple breath washout (MBW) testing in respiratory disease highlights the need for increased awareness amongst respiratory physiotherapists and a potential opportunity for professional development in the use of an important outcome measure for clinical trials. To rationalise how MBW may be a useful assessment tool for respiratory physiotherapists and to describe a local MBW training and certification programme for physiotherapists. The respiratory Multidisciplinary Team in the Belfast Health and Social Care Trust (BHSCT) identified a need for MBW testing to be available to facilitate clinical research and assessment. A 2day training programme consisting of prereading preparation, self-directed learning, theory presentations, practical demonstrations and hands-on practice was developed and delivered. All participants underwent a certification process. We have demonstrated the successful training and certification of clinical and research physiotherapists and encourage other respiratory physiotherapists to consider MBW test training. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  18. From One to Multiple Accents on a Test of L2 Listening Comprehension

    Science.gov (United States)

    Ockey, Gary J.; French, Robert

    2016-01-01

    Concerns about the need for assessing multidialectal listening skills for global contexts are becoming increasingly prevalent. However, the inclusion of multiple accents on listening assessments may threaten test fairness because it is not practical to include every accent that may be encountered in the language use domain on these tests. Given…

  19. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  20. Within-day variability on short and long walking tests in persons with multiple sclerosis

    NARCIS (Netherlands)

    Feys, P.; Bibby, B.; Romberg, A.; Santoyo, C.; Gebara, B.; de Noordhout, B.M.; Knuts, K.; Bethoux, F.; Skjerbaek, A.; Jensen, E.; Baert, I.; Vaney, C.; de Groot, V.; Dalgas, U.

    2014-01-01

    Objective To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Design Observational study. Setting MS rehabilitation and research centers in Europe and US within

  1. Hidden multiplicity in multiway ANOVA: Prevalence, consequences, and remedies. : Prevalence and remedies

    NARCIS (Netherlands)

    Cramer, Angélique O.J.; van Ravenzwaaij, Don; Matzke, Dora; Steingroever, Helen; Wetzels, Ruud; Grasman, Raoul P.P.P.; Waldorp, Lourens J.; Wagenmakers, Eric-Jan

    Many psychologists do not realize that exploratory use of the popular multiway analysis of variance harbors a multiple-comparison problem. In the case of two factors, three separate null hypotheses are subject to test (i.e., two main effects and one interaction). Consequently, the probability of at

  2. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    Science.gov (United States)

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  3. Comparison of likelihood testing procedures for parallel systems with covariances

    International Nuclear Information System (INIS)

    Ayman Baklizi; Isa Daud; Noor Akma Ibrahim

    1998-01-01

    In this paper we considered investigating and comparing the behavior of the likelihood ratio, the Rao's and the Wald's statistics for testing hypotheses on the parameters of the simple linear regression model based on parallel systems with covariances. These statistics are asymptotically equivalent (Barndorff-Nielsen and Cox, 1994). However, their relative performances in finite samples are generally known. A Monte Carlo experiment is conducted to stimulate the sizes and the powers of these statistics for complete samples and in the presence of time censoring. Comparisons of the statistics are made according to the attainment of assumed size of the test and their powers at various points in the parameter space. The results show that the likelihood ratio statistics appears to have the best performance in terms of the attainment of the assumed size of the test. Power comparisons show that the Rao statistic has some advantage over the Wald statistic in almost all of the space of alternatives while likelihood ratio statistic occupies either the first or the last position in term of power. Overall, the likelihood ratio statistic appears to be more appropriate to the model under study, especially for small sample sizes

  4. A Sequential Circuit-Based IP Watermarking Algorithm for Multiple Scan Chains in Design-for-Test

    Directory of Open Access Journals (Sweden)

    C. Wu

    2011-06-01

    Full Text Available In Very Large Scale Integrated Circuits (VLSI design, the existing Design-for-Test(DFT based watermarking techniques usually insert watermark through reordering scan cells, which causes large resource overhead, low security and coverage rate of watermark detection. A novel scheme was proposed to watermark multiple scan chains in DFT for solving the problems. The proposed scheme adopts DFT scan test model of VLSI design, and uses a Linear Feedback Shift Register (LFSR for pseudo random test vector generation. All of the test vectors are shifted in scan input for the construction of multiple scan chains with minimum correlation. Specific registers in multiple scan chains will be changed by the watermark circuit for watermarking the design. The watermark can be effectively detected without interference with normal function of the circuit, even after the chip is packaged. The experimental results on several ISCAS benchmarks show that the proposed scheme has lower resource overhead, probability of coincidence and higher coverage rate of watermark detection by comparing with the existing methods.

  5. Multiple-Choice versus Constructed-Response Tests in the Assessment of Mathematics Computation Skills.

    Science.gov (United States)

    Gadalla, Tahany M.

    The equivalence of multiple-choice (MC) and constructed response (discrete) (CR-D) response formats as applied to mathematics computation at grade levels two to six was tested. The difference between total scores from the two response formats was tested for statistical significance, and the factor structure of items in both response formats was…

  6. Development of a multiple immunoaffinity column for simultaneous determination of multiple mycotoxins in feeds using UPLC-MS/MS.

    Science.gov (United States)

    Hu, Xiaofeng; Hu, Rui; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Wang, Min

    2016-09-01

    A sensitive and specific immunoaffinity column to clean up and isolate multiple mycotoxins was developed along with a rapid one-step sample preparation procedure for ultra-performance liquid chromatography-tandem mass spectrometry analysis. Monoclonal antibodies against aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2, zearalenone, ochratoxin A, sterigmatocystin, and T-2 toxin were coupled to microbeads for mycotoxin purification. We optimized a homogenization and extraction procedure as well as column loading and elution conditions to maximize recoveries from complex feed matrices. This method allowed rapid, simple, and simultaneous determination of mycotoxins in feeds with a single chromatographic run. Detection limits for these toxins ranged from 0.006 to 0.12 ng mL(-1), and quantitation limits ranged from 0.06 to 0.75 ng mL(-1). Concentration curves were linear from 0.12 to 40 μg kg(-1) with correlation coefficients of R (2) > 0.99. Intra-assay and inter-assay comparisons indicated excellent repeatability and reproducibility of the multiple immunoaffinity columns. As a proof of principle, 80 feed samples were tested and several contained multiple mycotoxins. This method is sensitive, rapid, and durable enough for multiple mycotoxin determinations that fulfill European Union and Chinese testing criteria.

  7. Cascade Distillation Subsystem Development: Progress Toward a Distillation Comparison Test

    Science.gov (United States)

    Callahan, M. R.; Lubman, A.; Pickering, Karen D.

    2009-01-01

    Recovery of potable water from wastewater is essential for the success of long-duration manned missions to the Moon and Mars. Honeywell International and a team from NASA Johnson Space Center (JSC) are developing a wastewater processing subsystem that is based on centrifugal vacuum distillation. The wastewater processor, referred to as the Cascade Distillation Subsystem (CDS), utilizes an innovative and efficient multistage thermodynamic process to produce purified water. The rotary centrifugal design of the system also provides gas/liquid phase separation and liquid transport under microgravity conditions. A five-stage subsystem unit has been designed, built, delivered and integrated into the NASA JSC Advanced Water Recovery Systems Development Facility for performance testing. A major test objective of the project is to demonstrate the advancement of the CDS technology from the breadboard level to a subsystem level unit. An initial round of CDS performance testing was completed in fiscal year (FY) 2008. Based on FY08 testing, the system is now in development to support an Exploration Life Support (ELS) Project distillation comparison test expected to begin in early 2009. As part of the project objectives planned for FY09, the system will be reconfigured to support the ELS comparison test. The CDS will then be challenged with a series of human-gene-rated waste streams representative of those anticipated for a lunar outpost. This paper provides a description of the CDS technology, a status of the current project activities, and data on the system s performance to date.

  8. Cognitive performance of neuromyelitis optica patients: comparison with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Sandra Vanotti

    2013-06-01

    Full Text Available The aim of the present research was to investigate cognitive pattern of patients with neuromyelitis optica (NMO and to compare it with multiple sclerosis (MS patients' performance. Methods: Fourteen NMO, 14 relapsing remitting multiple sclerosis (RRMS, and 14 healthy control patients participated in the investigation. Neuropsychological functions were evaluated with the Brief Repeatable Neuropsychological Battery for MS; Symbol Digit Modalities Test; Digit Span; and Semantic Fluency. Results: Fifty-seven percent of NMO patients and 42.85% of the MS ones had abnormal performance in at least two cognitive tests. The NMO Group showed abnormal performance in verbal fluency, verbal and visual memories, with greater attention deficits. NMO patients outperformed healthy control in the paced auditory serial addition test (PASAT. However, no difference was found between NMO and RRMS patients. Conclusions: The NMO Group showed more dysfunction in attention and verbal fluencies than in verbal and visual memories. When compared with the MS patients, a similar dysfunction pattern was found. O objetivo da presente pesquisa foi investigar o padrão cognitivo de pacientes com neuromielite óptica (NMO e compará-lo com o desempenho de pacientes com esclerose múltipla (EM. Métodos: Quatorze pacientes com NMO, 14 com esclerose múltipla recorrente remitente (EMRR e 14 participantes do Controle saudáveis participaram da presente investigação. As funções neuropsicológicas foram avaliadas com a Bateria Breve de Testes Neuropsicológicos de Rao, Teste Símbolo Digit e a Fluência Semântica. Resultados: Cinquenta e sete por cento dos pacientes com NMO e 42,85% daqueles com EM apresentaram desempenho anormal em pelo menos dois testes cognitivos. O Grupo NMO apresentarou desempenho anormal na fluência verbal e nas memórias visual e verbal, com maiores déficits de atenção. Pacientes com NMO superaram os controles saudáveis em PASAT. No entanto, não foi

  9. Social Comparison, Multiple Reference Groups, and the Self-Concepts of Academically Handicapped Children Before and After Mainstreaming.

    Science.gov (United States)

    Strang, Louise; And Others

    1978-01-01

    Predictions from social comparison theory and group reference theory were tested in two experiments assessing the impact of half-day mainstreaming upon the self-concepts of academically handicapped children. The results supported the theoretical viability of social comparison theory and group reference theory in educational settings. (Author/BH)

  10. Comparison of aquifer characteristics derived from local and regional aquifer tests.

    Science.gov (United States)

    Randolph, R.B.; Krause, R.E.; Maslia, M.L.

    1985-01-01

    A comparison of the aquifer parameter values obtained through the analysis of a local and a regional aquifer test involving the same area in southeast Georgia is made in order to evaluate the validity of extrapolating local aquifer-test results for use in large-scale flow simulations. Time-drawdown and time-recovery data were analyzed by using both graphical and least-squares fitting of the data to the Theis curve. Additionally, directional transmissivity, transmissivity tensor, and angle of anisotropy were computed for both tests. -from Authors Georgia drawdown transmissivity regional aquifer tests

  11. A Studentized Permutation Test for the Comparison of Spatial Point Patterns

    DEFF Research Database (Denmark)

    Hahn, Ute

    of empirical K-functions are compared by a permutation test using a studentized test statistic. The proposed test performs convincingly in terms of empirical level and power in a simulation study, even for point patterns where the K-function estimates on neighboring subsamples are not strictly exchangeable....... It also shows improved behavior compared to a test suggested by Diggle et al. (1991, 2000) for the comparison of groups of independently replicated point patterns. In an application to two point patterns from pathology that represent capillary positions in sections of healthy and tumorous tissue, our...

  12. Design and performance of beam test electronics for the PHENIX multiplicity vertex detector

    International Nuclear Information System (INIS)

    Britton, C.L. Jr.; Bryan, W.L.; Emery, M.S.

    1996-01-01

    The system architecture and test results of the custom circuits and beam test system for the Multiplicity-Vertex Detector (MVD) for the PHENIX detector collaboration at the Relativistic Heavy Ion Collider (RHIC) are presented in this paper. The final detector per-channel signal processing chain will consist of a preamplifier-gain stage, a current-mode summed multiplicity discriminator, a 64-deep analog memory (simultaneous read-write), a post-memory analog correlator, and a 10-bit 5 μs ADC. The Heap Manager provides all timing control, data buffering, and data formatting for a single 256-channel multi-chip module (MCM). Each chip set is partitioned into 32-channel sets. Beam test (16-cell deep memory) performance for the various blocks will be presented as well as the ionizing radiation damage performance of the 1.2 μ n-well CMOS process used for preamplifier fabrication

  13. Comparison of students' foodservice satisfaction between Korea and US

    OpenAIRE

    Jeong, Eunkyung; Chun, Youngah; Joo, Nami; Yoon, Ji-young

    2013-01-01

    This study analyzes important factors of foodservice in school through comparison of students' satisfaction of using foodservice in Korea and US in order to meet students' expectations. The survey was composed of 4 categories including menu, service, hygiene, and facility and it was carried out in both countries to evaluate satisfaction. First, comparison of satisfaction between two countries was made using t-test. Secondly, multiple regression was performed to identify factors affecting sati...

  14. Validity of multiple stress creep recovery test for LADOTD asphalt binder specification.

    Science.gov (United States)

    2010-09-01

    The objectives of this research are to characterize the elastic response of various binders used by LADOTD to determine the feasibility of the Multiple Stress Creep Recovery (MSCR) test to be included in the LADOTD asphalt binder specification and to...

  15. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    Science.gov (United States)

    Trout, Dawn H.; Burford, Janessa

    2013-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  16. Influence of selected test parameters on measured values during the MSCR test

    Science.gov (United States)

    Benešová, Lucie; Valentin, Jan

    2017-09-01

    One of today’s most commonly used test on a Dynamic Shear Rheometer (DSR) is the Multiple Stress Creep Recovery (MSCR) test. The test is described in the standard EN 16659, which is valid in the Czech Republic since October 2016. The principle of the test is based on repeated loading and recovering of a bitumen sample, according to which it is possible to determine the percentage of elastic recovery (R) and non-recoverable creep compliance (Jnr) of the bituminous binder. This method has been recently promoted as the most suitable test for assessing the resistance of bituminous binders to permanent deformation. The test is performed at higher temperatures and is particularly suitable for modified bituminous binders. The paper deals with the comparison of the different input parameters set on the DSR device - different levels of stress, temperature of test, the geometry of the measuring device and also a comparison of the results for a different number of loading cycles. The research study was focused mainly on modified bituminous binders, but to compare the MSCR test it is performed even with conventional paving grade binders.

  17. Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Elder, J.; Vandekamp, R.

    2011-02-10

    Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

  18. The relationship between Test Takers’ Multiple Intelligences and Their Performance on the Reading Sections of TOEFL and IELTS

    Directory of Open Access Journals (Sweden)

    Minoo Alemi

    2010-04-01

    Full Text Available The present study aimed at investigating the hypothetical relationship between the multiple intelligences of test takers and their performance on the reading sections of TOEFL and IELTS. Howard Gardner’s theory of multiple intelligences suggests that intelligence is not a single and solely inborn capacity, rather a multiple construct which is only partly genetic, and can be crystallized or paralyzed over one’s lifetime. Based on the theory, there are eight types of intelligence: linguistic, mathematical, musical, bodily, spatial, intrapersonal, interpersonal and naturalist, but the list is not exhaustive. The multiple intelligences of test takers were estimated by means of MIDAS, the Multiple Intelligences Developmental Assessment Scales, developed by Shearer (1994. Subsequently, the bias detection for the reading section of TOEFL was carried out on 90 participants, and this subtest was found to correlate positively with linguistic and logical intelligences. By the same token, 89 out of the 163 participants in the study were included in the analysis of the relationship between the multiple intelligences of test takers and their performance on the reading section of IELTS, and this test proved biased toward linguistic and spatial intelligences. The implications concern the inadequacy of the definition of language proficiency .Moreover, Measurement-Driven Instruction courses and preparatory materials of the two proficiency tests, TOEFL and IELTS, can benefit from the results of the study by being designed in such a way as to represent the intelligences which are positively correlated with performance on the tests in question.

  19. Testing multiple coordination constraints with a novel bimanual visuomotor task.

    Directory of Open Access Journals (Sweden)

    Helene M Sisti

    Full Text Available The acquisition of a new bimanual skill depends on several motor coordination constraints. To date, coordination constraints have often been tested relatively independently of one another, particularly with respect to isofrequency and multifrequency rhythms. Here, we used a new paradigm to test the interaction of multiple coordination constraints. Coordination constraints that were tested included temporal complexity, directionality, muscle grouping, and hand dominance. Twenty-two healthy young adults performed a bimanual dial rotation task that required left and right hand coordination to track a moving target on a computer monitor. Two groups were compared, either with or without four days of practice with augmented visual feedback. Four directional patterns were tested such that both hands moved either rightward (clockwise, leftward (counterclockwise, inward or outward relative to each other. Seven frequency ratios (3∶1, 2∶1, 3∶2, 1∶1, 2∶3. 1∶2, 1∶3 between the left and right hand were introduced. As expected, isofrequency patterns (1∶1 were performed more successfully than multifrequency patterns (non 1∶1. In addition, performance was more accurate when participants were required to move faster with the dominant right hand (1∶3, 1∶2 and 2∶3 than with the non-dominant left hand (3∶1, 2∶1, 3∶2. Interestingly, performance deteriorated as the relative angular velocity between the two hands increased, regardless of whether the required frequency ratio was an integer or non-integer. This contrasted with previous finger tapping research where the integer ratios generally led to less error than the non-integer ratios. We suggest that this is due to the different movement topologies that are required of each paradigm. Overall, we found that this visuomotor task was useful for testing the interaction of multiple coordination constraints as well as the release from these constraints with practice in the presence of

  20. Global testing under sparse alternatives: ANOVA, multiple comparisons and the higher criticism

    OpenAIRE

    Arias-Castro, Ery; Candès, Emmanuel J.; Plan, Yaniv

    2011-01-01

    Testing for the significance of a subset of regression coefficients in a linear model, a staple of statistical analysis, goes back at least to the work of Fisher who introduced the analysis of variance (ANOVA). We study this problem under the assumption that the coefficient vector is sparse, a common situation in modern high-dimensional settings. Suppose we have $p$ covariates and that under the alternative, the response only depends upon the order of $p^{1-\\alpha}$ of those, $0\\le\\alpha\\le1$...

  1. A Particle Swarm Optimization Approach to Composing Serial Test Sheets for Multiple Assessment Criteria

    Science.gov (United States)

    Yin, Peng-Yeng; Chang, Kuang-Cheng; Hwang, Gwo-Jen; Hwang, Gwo-Haur; Chan, Ying

    2006-01-01

    To accurately analyze the problems of students in learning, the composed test sheets must meet multiple assessment criteria, such as the ratio of relevant concepts to be evaluated, the average discrimination degree, difficulty degree and estimated testing time. Furthermore, to precisely evaluate the improvement of student's learning performance…

  2. Comparison of ASTECV1.3.2 and ASTECV2 results for QUENCH 12 test

    International Nuclear Information System (INIS)

    Stefanova, A.

    2010-01-01

    This paper presents a comparison of QUENCH 12 test calculated results with ASTECv1.3R2 and ASTECv2 computer codes. The test was performed to investigate the behavior of VVER fuel assemblies. This investigation is a part of the 6th and 7th framework programs of the EC supported ISTC program. The test facility is located at Forschungszentrum in Karlsruhe. The structure of the test facility allows experimental studies under transient and accident conditions. The ASTEC1.3R2 and ASTECv2 computer codes have been used to simulate the investigated test. The base line input model for ASTEC was provided from Forschungszentrum, Karlsruhe. During the preparation of QUENCH - 12 experiment, the input deck was adapted to new initial and boundary conditions. The comparison show good agreement between measured data and ASTEC calculated results. (author)

  3. Semiparametric Allelic Tests for Mapping Multiple Phenotypes: Binomial Regression and Mahalanobis Distance.

    Science.gov (United States)

    Majumdar, Arunabha; Witte, John S; Ghosh, Saurabh

    2015-12-01

    Binary phenotypes commonly arise due to multiple underlying quantitative precursors and genetic variants may impact multiple traits in a pleiotropic manner. Hence, simultaneously analyzing such correlated traits may be more powerful than analyzing individual traits. Various genotype-level methods, e.g., MultiPhen (O'Reilly et al. []), have been developed to identify genetic factors underlying a multivariate phenotype. For univariate phenotypes, the usefulness and applicability of allele-level tests have been investigated. The test of allele frequency difference among cases and controls is commonly used for mapping case-control association. However, allelic methods for multivariate association mapping have not been studied much. In this article, we explore two allelic tests of multivariate association: one using a Binomial regression model based on inverted regression of genotype on phenotype (Binomial regression-based Association of Multivariate Phenotypes [BAMP]), and the other employing the Mahalanobis distance between two sample means of the multivariate phenotype vector for two alleles at a single-nucleotide polymorphism (Distance-based Association of Multivariate Phenotypes [DAMP]). These methods can incorporate both discrete and continuous phenotypes. Some theoretical properties for BAMP are studied. Using simulations, the power of the methods for detecting multivariate association is compared with the genotype-level test MultiPhen's. The allelic tests yield marginally higher power than MultiPhen for multivariate phenotypes. For one/two binary traits under recessive mode of inheritance, allelic tests are found to be substantially more powerful. All three tests are applied to two different real data and the results offer some support for the simulation study. We propose a hybrid approach for testing multivariate association that implements MultiPhen when Hardy-Weinberg Equilibrium (HWE) is violated and BAMP otherwise, because the allelic approaches assume HWE

  4. Cascade Distillation Subsystem Development: Early Results from the Exploration Life Support Distillation Technology Comparison Test

    Science.gov (United States)

    Callahan, Michael R.; Patel, Vipul; Pickering, Karen D.

    2010-01-01

    In 2009, the Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, California) was assessed in the National Aeronautics and Space Administration (NASA) Exploration Life Support (ELS) distillation comparison test. The purpose of the test was to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. The CDS portion of the comparison test was conducted between May 6 and August 19, 2009. The system was challenged with two pretreated test solutions, each intended to represent a feasible wastewater generated in a surface habitat. The 30-day equivalent wastewater loading volume for a crew of four was intended to be processed for each wastewater solution. Test Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. Test Solution 2 contained the addition of human-generated hygiene wastewater to the solution 1 waste stream components. Approximately 1500 kg of total wastewater was processed through the CDS during testing. Respective recoveries per solution were 93.4 +/- 0.7 and 90.3 +/- 0.5 percent. The average specific energy of the system during testing was calculated to be less than 120 W-hr/kg. The following paper provides detailed information and data on the performance of the CDS as challenged per the ELS distillation comparison test.

  5. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  6. Data for Room Fire Model Comparisons.

    Science.gov (United States)

    Peacock, Richard D; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.

  7. Data for Room Fire Model Comparisons

    Science.gov (United States)

    Peacock, Richard D.; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system. PMID:28184121

  8. Phase-Retrieval Uncertainty Estimation and Algorithm Comparison for the JWST-ISIM Test Campaign

    Science.gov (United States)

    Aronstein, David L.; Smith, J. Scott

    2016-01-01

    Phase retrieval, the process of determining the exitpupil wavefront of an optical instrument from image-plane intensity measurements, is the baseline methodology for characterizing the wavefront for the suite of science instruments (SIs) in the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST). JWST is a large, infrared space telescope with a 6.5-meter diameter primary mirror. JWST is currently NASA's flagship mission and will be the premier space observatory of the next decade. ISIM contains four optical benches with nine unique instruments, including redundancies. ISIM was characterized at the Goddard Space Flight Center (GSFC) in Greenbelt, MD in a series of cryogenic vacuum tests using a telescope simulator. During these tests, phase-retrieval algorithms were used to characterize the instruments. The objective of this paper is to describe the Monte-Carlo simulations that were used to establish uncertainties (i.e., error bars) for the wavefronts of the various instruments in ISIM. Multiple retrieval algorithms were used in the analysis of ISIM phase-retrieval focus-sweep data, including an iterativetransform algorithm and a nonlinear optimization algorithm. These algorithms emphasize the recovery of numerous optical parameters, including low-order wavefront composition described by Zernike polynomial terms and high-order wavefront described by a point-by-point map, location of instrument best focus, focal ratio, exit-pupil amplitude, the morphology of any extended object, and optical jitter. The secondary objective of this paper is to report on the relative accuracies of these algorithms for the ISIM instrument tests, and a comparison of their computational complexity and their performance on central and graphical processing unit clusters. From a phase-retrieval perspective, the ISIM test campaign includes a variety of source illumination bandwidths, various image-plane sampling criteria above and below the Nyquist- Shannon

  9. Learners Test Performance and Gardner`s Multiple Inteligence Theory: Intercorrelation in a Bilingual Context

    Directory of Open Access Journals (Sweden)

    Bagher Azarmi

    2015-03-01

    Full Text Available Although decisions and inferences made based on test scores depend both on the characteristics of test takers and testing environment, the former seems to have the most overridingimportance. The present study which was conducted in a bilingual environment is in line with this assumption and is aimed at investigating intelligence as one of the test taker characteristics. First, it aimed at finding the possible correlation between any of the eight types of intelligences in Gardner`s MI theory and EAP test performance. Second, it intended to survey the intercorrelationamong the eight types of intelligences themselves. To that end, 122 male bilingual EFL learners who were all sophomore university students were chosen as the participants of the study. They satfor the final EAP exam and filled the questionnaire on multiple intelligence. The test takers' scores on EAP exam were correlated with their multiple intelligences. The result did not demonstrate anystatistically significant go-togetherness between EAP test performance and any types of intelligence; however, a significantly positive correlation was observed among the eight types of intelligences themselves showing that all types of intelligences are equally important and ought to be equally dealt with in EFL context.

  10. Multiple treatment comparisons in epilepsy monotherapy trials

    Directory of Open Access Journals (Sweden)

    Chadwick David W

    2007-11-01

    Full Text Available Abstract Background The choice of antiepileptic drug for an individual should be based upon the highest quality evidence regarding potential benefits and harms of the available treatments. Systematic reviews and meta-analysis of randomised controlled trials should be a major source of evidence supporting this decision making process. We summarise all available individual patient data evidence from randomised controlled trials that compared at least two out of eight antiepileptic drugs given as monotherapy. Methods Multiple treatment comparisons from epilepsy monotherapy trials were synthesized in a single stratified Cox regression model adjusted for treatment by epilepsy type interactions and making use of direct and indirect evidence. Primary outcomes were time to treatment failure and time to 12 month remission from seizures. A secondary outcome was time to first seizure. Results Individual patient data for 6418 patients from 20 randomised trials comparing eight antiepileptic drugs were synthesized. For partial onset seizures (4628 (72% patients, lamotrigine, carbamazepine and oxcarbazepine provide the best combination of seizure control and treatment failure. Lamotrigine is clinically superior to all other drugs for treatment failure but estimates suggest a disadvantage compared to carbamazepine for time to 12 month remission [Hazard Ratio (95% Confidence Interval = 0.87(0.73 to 1.04] and time to first seizure [1.29(1.13 to 1.48]. Phenobarbitone may delay time to first seizure [0.77(0.61 to 0.96] but at the expense of increased treatment failure [1.60(1.22 to 2.10]. For generalized onset tonic clonic seizures (1790 (28% patients estimates suggest valproate or phenytoin may provide the best combination of seizure control and treatment failure but some uncertainty remains about the relative effectiveness of other drugs. Conclusion For patients with partial onset seizures, results favour carbamazepine, oxcarbazepine and lamotrigine. For

  11. Comparison of test and earthquake response modeling of a nuclear power plant containment building

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1985-01-01

    The reactor building of a BWR plant was subjected to dynamic testing, a minor earthquake, and a strong earthquake at different times. Analytical models simulating each of these events were devised by previous investigators. A comparison of the characteristics of these models is made in this paper. The different modeling assumptions involved in the different simulation analyses restrict the validity of the models for general use and also narrow the comparison down to only a few modes. The dynamic tests successfully identified the first mode of the soil-structure system.

  12. Comparison of test and earthquake response modeling of a nuclear power plant containment building

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1985-01-01

    The reactor building of a BWR plant was subjected to dynamic testing, a minor earthquake, and a strong earthquake at different times. Analytical models simulating each of these events were devised by previous investigators. A comparison of the characteristics of these models is made in this paper. The different modeling assumptions involved in the different simulation analyses restrict the validity of the models for general use and also narrow the comparison down to only a few modes. The dynamic tests successfully identified the first mode of the soil-structure system

  13. Proving test on the performance of a Multiple-Excitation Simulator

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Ito, Tomohiro; Kojima, Nobuyuki; Sasaki, Yoichi; Abe, Hiroshi; Kuroda, Katsuhiko

    1995-01-01

    Seismic excitation test on large scale piping systems is scheduled to be carried out by the Nuclear power Engineering Corporation (NUPEC) using the large-scale, high-performance vibration table at the Tadotsu Engineering Laboratory, under the sponsorship of the Ministry of International Trade and Industry (MITI). In the test, the piping systems simulate the main steam piping system and the main feed water piping system in the nuclear power plants. In this study, a fundamental test was carried out to prove the performance of the Multiple Excitation Simulator which consists of the hydraulic actuator and the control system. An L-shaped piping system and a hydraulic actuator were installed on the shaking table. Acceleration and displacement generated by the actuator were measured. The performance of the actuator and the control system was discussed comparing the measured values and the target values on the time histories and the response spectrum of the acceleration. As a result, it was proved that the actuator and the control system have good performance and will be applicable to the verification test

  14. Method for aquatic multiple species toxicant testing: acute toxicity of 10 chemicals to 5 vertebrates and 2 invertebrates. [Pimephales promelas; Carassius auratus; Ictalurus punctatus; Lepomis macrochirus; Salmo gairdneri; Orconectes immunis; Aplexa hypnorum

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.L.; Holcombe, G.W.

    1985-01-01

    A method was developed to simultaneously ascertain 96 h LC/sub 50/ values for seven freshwater species in a single flow through test with measured concentrations. It allows interspecific comparisons, easy determination of the most sensitive species, and cuts cost of labor, materials and chemical analysis for measured concentration tests. Species tested included fathead minnows Pimephales promelas, goldfish Carassius auratus, channel catfish Ictalurus punctatus, bluegill Lepomis macrochirus, rainbow trout Salmo gairdneri, crayfish Orconectes immunis and snails Aplexa hypnorum. Compounds tested were pentachlorophenol, 2-chloroethanol, 2,4-pentanedione, hexachloroethane, ..cap alpha..-bromo-2',5'-dimethoxyacetophenone, benzaldehyde, 1,3-dichloro-4,6-dinitro-benzene, dursban, sevin and cadmium chloride. The LC/sub 50/ values from these multiple species tests compared favourably with those determined using single species tests at this laboratory, usually within 20%.

  15. Comparison of transient PCRV model test results with analysis

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Belytschko, T.B.

    1979-01-01

    Comparisons are made of transient data derived from simple models of a reactor containment vessel with analytical solutions. This effort is a part of the ongoing process of development and testing of the DYNAPCON computer code. The test results used in these comparisons were obtained from scaled models of the British sodium cooled fast breeder program. The test structure is a scaled model of a cylindrically shaped reactor containment vessel made of concrete. This concrete vessel is prestressed axially by holddown bolts spanning the top and bottom slabs along the cylindrical walls, and is also prestressed circumferentially by a number of cables wrapped around the vessel. For test purposes this containment vessel is partially filled with water, which comes in direct contact with the vessel walls. The explosive charge is immersed in the pool of water and is centrally suspended from the top of the vessel. The load history was obtained from an ICECO analysis, using the equations of state for the source and the water. A detailed check of this solution was made to assure that the derived loading did provide the correct input. The DYNAPCON code was then used for the analysis of the prestressed concrete containment model. This analysis required the simulation of prestressing and the response of the model to the applied transient load. The calculations correctly predict the magnitudes of displacements of the PCRV model. In addition, the displacement time histories obtained from the calculations reproduce the general features of the experimental records: the period elongation and amplitude increase as compared to an elastic solution, and also the absence of permanent displacement. However, the period still underestimates the experiment, while the amplitude is generally somewhat large

  16. Comparison between Two Assessment Methods; Modified Essay Questions and Multiple Choice Questions

    Directory of Open Access Journals (Sweden)

    Assadi S.N.* MD

    2015-09-01

    Full Text Available Aims Using the best assessment methods is an important factor in educational development of health students. Modified essay questions and multiple choice questions are two prevalent methods of assessing the students. The aim of this study was to compare two methods of modified essay questions and multiple choice questions in occupational health engineering and work laws courses. Materials & Methods This semi-experimental study was performed during 2013 to 2014 on occupational health students of Mashhad University of Medical Sciences. The class of occupational health and work laws course in 2013 was considered as group A and the class of 2014 as group B. Each group had 50 students.The group A students were assessed by modified essay questions method and the group B by multiple choice questions method.Data were analyzed in SPSS 16 software by paired T test and odd’s ratio. Findings The mean grade of occupational health and work laws course was 18.68±0.91 in group A (modified essay questions and was 18.78±0.86 in group B (multiple choice questions which was not significantly different (t=-0.41; p=0.684. The mean grade of chemical chapter (p<0.001 in occupational health engineering and harmful work law (p<0.001 and other (p=0.015 chapters in work laws were significantly different between two groups. Conclusion Modified essay questions and multiple choice questions methods have nearly the same student assessing value for the occupational health engineering and work laws course.

  17. Comparison of vibration test results for Atucha II NPP and large scale concrete block models

    International Nuclear Information System (INIS)

    Iizuka, S.; Konno, T.; Prato, C.A.

    2001-01-01

    In order to study the soil structure interaction of reactor building that could be constructed on a Quaternary soil, a comparison study of the soil structure interaction springs was performed between full scale vibration test results of Atucha II NPP and vibration test results of large scale concrete block models constructed on Quaternary soil. This comparison study provides a case data of soil structure interaction springs on Quaternary soil with different foundation size and stiffness. (author)

  18. Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Directory of Open Access Journals (Sweden)

    Ujhelyi Gabriella

    2012-01-01

    Full Text Available Abstract Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i hybridisation and ligation of specific probes, ii amplification of the ligated probes and iii detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands. Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the

  19. Multiple Whole Genome Alignments Without a Reference Organism

    Energy Technology Data Exchange (ETDEWEB)

    Dubchak, Inna; Poliakov, Alexander; Kislyuk, Andrey; Brudno, Michael

    2009-01-16

    Multiple sequence alignments have become one of the most commonly used resources in genomics research. Most algorithms for multiple alignment of whole genomes rely either on a reference genome, against which all of the other sequences are laid out, or require a one-to-one mapping between the nucleotides of the genomes, preventing the alignment of recently duplicated regions. Both approaches have drawbacks for whole-genome comparisons. In this paper we present a novel symmetric alignment algorithm. The resulting alignments not only represent all of the genomes equally well, but also include all relevant duplications that occurred since the divergence from the last common ancestor. Our algorithm, implemented as a part of the VISTA Genome Pipeline (VGP), was used to align seven vertebrate and sixDrosophila genomes. The resulting whole-genome alignments demonstrate a higher sensitivity and specificity than the pairwise alignments previously available through the VGP and have higher exon alignment accuracy than comparable public whole-genome alignments. Of the multiple alignment methods tested, ours performed the best at aligning genes from multigene families?perhaps the most challenging test for whole-genome alignments. Our whole-genome multiple alignments are available through the VISTA Browser at http://genome.lbl.gov/vista/index.shtml.

  20. Multiloop integral system test (MIST): Final report, Inter-group comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Gloudemans, J.R.

    1989-07-01

    The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock and Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility -- the once-through integral system (OTIS) -- was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The individual tests are described in detail in Volumes 2 through 8 and Volume 11, and are summarized in Volume 1. Inter-group comparisons are addressed in this document, Volume 9. These comparisons are grouped as follows: mapping versus SBLOCA transients, SBLOCA, pump effects, and the effects of noncondensible gases. Appendix A provides an index and description of the microfiched plots for each test, which are enclosed with the corresponding Volumes 2 through 8. 147 figs., 5 tabs.

  1. Multiple comparison procedures for neuroimaging genomewide association studies.

    Science.gov (United States)

    Hua, Wen-Yu; Nichols, Thomas E; Ghosh, Debashis

    2015-01-01

    Recent research in neuroimaging has focused on assessing associations between genetic variants that are measured on a genomewide scale and brain imaging phenotypes. A large number of works in the area apply massively univariate analyses on a genomewide basis to find single nucleotide polymorphisms that influence brain structure. In this paper, we propose using various dimensionality reduction methods on both brain structural MRI scans and genomic data, motivated by the Alzheimer's Disease Neuroimaging Initiative (ADNI) study. We also consider a new multiple testing adjustment method and compare it with two existing false discovery rate (FDR) adjustment methods. The simulation results suggest an increase in power for the proposed method. The real-data analysis suggests that the proposed procedure is able to find associations between genetic variants and brain volume differences that offer potentially new biological insights. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Pulse Jet Mixer Overblow Testing for Assessment of Loadings During Multiple Overblows

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Bontha, Jagannadha R.; Michener, Thomas E.; Nigl, Franz; Yokuda, Satoru T.; Leigh, Richard J.; Golovich, Elizabeth C.; Baumann, Aaron W.; Kurath, Dean E.; Hoza, Mark; Combs, William H.; Fort, James A.; Bredt, Ofelia P.

    2009-07-20

    The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities: pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste feed from the Hanford tank farms and separate it into 1) a high-volume, low-activity liquid stream stripped of most solids and radionuclides and 2) a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJMs) that will provide some or all of the mixing in the vessels. This technology was selected for use in so-called “black cell” regions of the WTP, where maintenance capability will not be available for the operating life of the WTP. PJM technology was selected for use in these regions because it has no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. This report contains the results of single and multiple PJM overblow tests conducted in a large, ~13 ft-diameter × 15-ft-tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. These single and multiple PJM overblow tests were conducted using water and a clay simulant to bound the lower and upper rheological properties of the waste streams anticipated to be processed in the WTP. Hydrodynamic pressures were measured at a number of locations in the test vessel using an array of nine pressure sensors and four hydrophones. These measurements were made under normal and limiting vessel operating conditions (i.e., maximum PJM fluid emptying velocity, maximum and minimum vessel

  3. Pulse Jet Mixer Overblow Testing for Assessment of Loadings During Multiple Overblows

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Bontha, Jagannadha R.; Michener, Thomas E.; Nigl, Franz; Yokuda, Satoru T.; Leigh, Richard J.; Golovich, Elizabeth C.; Baumann, Aaron W.; Kurath, Dean E.; Hoza, Mark; Combs, William H.; Fort, James A.; Bredt, Ofelia P.

    2008-03-03

    The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities: pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste feed from the Hanford tank farms and separate it into 1) a high-volume, low-activity liquid stream stripped of most solids and radionuclides and 2) a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJMs) that will provide some or all of the mixing in the vessels. This technology was selected for use in so-called “black cell” regions of the WTP, where maintenance capability will not be available for the operating life of the WTP. PJM technology was selected for use in these regions because it has no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. This report contains the results of single and multiple PJM overblow tests conducted in a large, ~13 ft-diameter × 15-ft-tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. These single and multiple PJM overblow tests were conducted using water and a clay simulant to bound the lower and upper rheological properties of the waste streams anticipated to be processed in the WTP. Hydrodynamic pressures were measured at a number of locations in the test vessel using an array of nine pressure sensors and four hydrophones. These measurements were made under normal and limiting vessel operating conditions (i.e., maximum PJM fluid emptying velocity, maximum and minimum vessel

  4. Comparison of LOFT zero power physics testing measurement results with predicted values

    International Nuclear Information System (INIS)

    Rushton, B.L.; Howe, T.M.

    1978-01-01

    The results of zero power physics testing measurements in LOFT have been evaluated to assess the adequacy of the physics data used in the safety analyses performed for the LOFT FSAR and Technical Specifications. Comparisons of measured data with computed data were made for control rod worths, temperature coefficients, boron worths, and pressure coefficients. Measured boron concentrations at exact critical points were compared with predicted concentrations. Based on these comparisons, the reactivity parameter values used in the LOFT safety analyses were assessed for conservatism

  5. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    International Nuclear Information System (INIS)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-01-01

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers

  6. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng, E-mail: qschen@ujs.edu.cn

    2014-09-02

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers.

  7. Comparison of 200-liter and 40-milliliter leach tests

    International Nuclear Information System (INIS)

    Westsik, J.H. Jr.; Harvey, C.O.; Roberts, F.P.; Ross, W.A.; Thornhill, R.E.

    1982-01-01

    During the past year we have conducted a modified MCC-1 leach test on a 145 kg block of a cast cement waste form. The leach vessel was a 200 liter Teflon-lined drum and contained 97.5 liters of deionized water. The results of this large-scale leach test were compared with the results of standard MC-1 tests (40 ml) on smaller samples of the same waste form. The ratio of leachate volumes between the large and small scale tests was 2500 and the ratio of sample masses was 150,000. The cast cement samples for both tests contained plutonium-doped incinerator ash. The leachates from these tests were analyzed for both plutonium and the matrix elements. Evaluation of plutonium plateout in the large-scale test indicated that the majority of the plutonium leached from the samples deposits onto vessel walls and little ( -12 /sub M/) remains in solution. Comparison of elemental concentrations in the leachates indicates some differences up to 5X in the concentration in the large- and small-scale tests. The differences are attributed to differences in the solubilities of Ca, Si, and Fe at pH 11.5 and at pH 12.5. The higher pH observed for the large-scale test is a result of the larger quantities of sodium in the large block of cement

  8. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion.

    Science.gov (United States)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-09-02

    Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Comparison of charged particle multiplicity distributions in p tilde p and pp interactions and verification of the dual unitarization scheme

    International Nuclear Information System (INIS)

    Batyunya, B.V.; Boguslavsky, I.V.; Gramenitsky, I.M.

    1979-01-01

    The difference between antiproton annihilation and pp interactions has been discussed. Charged particle multiplicity distributions in anti pp-interactions at 22.4 GeV/c were used to obtain antiproton annihilation characteristics. The comparison of the topological cross section of antipp interactions with those of non-diffractive pp interactions confirms the validity of dual unitarization

  10. Testing a multiple mediation model of Asian American college students' willingness to see a counselor.

    Science.gov (United States)

    Kim, Paul Youngbin; Park, Irene J K

    2009-07-01

    Adapting the theory of reasoned action, the present study examined help-seeking beliefs, attitudes, and intent among Asian American college students (N = 110). A multiple mediation model was tested to see if the relation between Asian values and willingness to see a counselor was mediated by attitudes toward seeking professional psychological help and subjective norm. A bootstrapping procedure was used to test the multiple mediation model. Results indicated that subjective norm was the sole significant mediator of the effect of Asian values on willingness to see a counselor. The findings highlight the importance of social influences on help-seeking intent among Asian American college students.

  11. Empirical Comparison of Publication Bias Tests in Meta-Analysis.

    Science.gov (United States)

    Lin, Lifeng; Chu, Haitao; Murad, Mohammad Hassan; Hong, Chuan; Qu, Zhiyong; Cole, Stephen R; Chen, Yong

    2018-04-16

    Decision makers rely on meta-analytic estimates to trade off benefits and harms. Publication bias impairs the validity and generalizability of such estimates. The performance of various statistical tests for publication bias has been largely compared using simulation studies and has not been systematically evaluated in empirical data. This study compares seven commonly used publication bias tests (i.e., Begg's rank test, trim-and-fill, Egger's, Tang's, Macaskill's, Deeks', and Peters' regression tests) based on 28,655 meta-analyses available in the Cochrane Library. Egger's regression test detected publication bias more frequently than other tests (15.7% in meta-analyses of binary outcomes and 13.5% in meta-analyses of non-binary outcomes). The proportion of statistically significant publication bias tests was greater for larger meta-analyses, especially for Begg's rank test and the trim-and-fill method. The agreement among Tang's, Macaskill's, Deeks', and Peters' regression tests for binary outcomes was moderately strong (most κ's were around 0.6). Tang's and Deeks' tests had fairly similar performance (κ > 0.9). The agreement among Begg's rank test, the trim-and-fill method, and Egger's regression test was weak or moderate (κ < 0.5). Given the relatively low agreement between many publication bias tests, meta-analysts should not rely on a single test and may apply multiple tests with various assumptions. Non-statistical approaches to evaluating publication bias (e.g., searching clinical trials registries, records of drug approving agencies, and scientific conference proceedings) remain essential.

  12. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Jensen, K

    1990-01-01

    An investigation on the correlation between ability to read TV subtitles and the duration of visual evoked potential (VEP) latency in 14 patients with definite multiple sclerosis (MS), indicated that VEP latency in patients unable to read the TV subtitles was significantly delayed in comparison...

  13. PERMANOVA-S: association test for microbial community composition that accommodates confounders and multiple distances.

    Science.gov (United States)

    Tang, Zheng-Zheng; Chen, Guanhua; Alekseyenko, Alexander V

    2016-09-01

    Recent advances in sequencing technology have made it possible to obtain high-throughput data on the composition of microbial communities and to study the effects of dysbiosis on the human host. Analysis of pairwise intersample distances quantifies the association between the microbiome diversity and covariates of interest (e.g. environmental factors, clinical outcomes, treatment groups). In the design of these analyses, multiple choices for distance metrics are available. Most distance-based methods, however, use a single distance and are underpowered if the distance is poorly chosen. In addition, distance-based tests cannot flexibly handle confounding variables, which can result in excessive false-positive findings. We derive presence-weighted UniFrac to complement the existing UniFrac distances for more powerful detection of the variation in species richness. We develop PERMANOVA-S, a new distance-based method that tests the association of microbiome composition with any covariates of interest. PERMANOVA-S improves the commonly-used Permutation Multivariate Analysis of Variance (PERMANOVA) test by allowing flexible confounder adjustments and ensembling multiple distances. We conducted extensive simulation studies to evaluate the performance of different distances under various patterns of association. Our simulation studies demonstrate that the power of the test relies on how well the selected distance captures the nature of the association. The PERMANOVA-S unified test combines multiple distances and achieves good power regardless of the patterns of the underlying association. We demonstrate the usefulness of our approach by reanalyzing several real microbiome datasets. miProfile software is freely available at https://medschool.vanderbilt.edu/tang-lab/software/miProfile z.tang@vanderbilt.edu or g.chen@vanderbilt.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  14. Comparing long-term results of PASAT and SDMT scores in relation to neuropsychological testing in multiple sclerosis

    NARCIS (Netherlands)

    Sonder, J.M.; Burggraaff, J.; Knol, D.L.; Polman, C.H.; Uitdehaag, B.M.J.

    2014-01-01

    Background and objectives: The Symbol Digit Modalities Test (SDMT) shows advantages over the Paced Auditory Serial Addition Test (PASAT) as a cognitive test in patients with multiple sclerosis (MS). To determine which of these tests is most valid and reliable over time as an indicator of the

  15. A robust procedure for comparing multiple means under heteroscedasticity in unbalanced designs.

    Directory of Open Access Journals (Sweden)

    Esther Herberich

    2010-03-01

    Full Text Available Investigating differences between means of more than two groups or experimental conditions is a routine research question addressed in biology. In order to assess differences statistically, multiple comparison procedures are applied. The most prominent procedures of this type, the Dunnett and Tukey-Kramer test, control the probability of reporting at least one false positive result when the data are normally distributed and when the sample sizes and variances do not differ between groups. All three assumptions are non-realistic in biological research and any violation leads to an increased number of reported false positive results. Based on a general statistical framework for simultaneous inference and robust covariance estimators we propose a new statistical multiple comparison procedure for assessing multiple means. In contrast to the Dunnett or Tukey-Kramer tests, no assumptions regarding the distribution, sample sizes or variance homogeneity are necessary. The performance of the new procedure is assessed by means of its familywise error rate and power under different distributions. The practical merits are demonstrated by a reanalysis of fatty acid phenotypes of the bacterium Bacillus simplex from the "Evolution Canyons" I and II in Israel. The simulation results show that even under severely varying variances, the procedure controls the number of false positive findings very well. Thus, the here presented procedure works well under biologically realistic scenarios of unbalanced group sizes, non-normality and heteroscedasticity.

  16. The analysis of results of comparison test for radionuclides measurement through γ spectrum analysis from 2007 to 2012

    International Nuclear Information System (INIS)

    Wu Jialong; He Jian; Sun Wei; Wang Yun

    2013-01-01

    In order to test the capability of radionuclides measurement through γ spectrum analysis and improve the ability of the technicians by inter-laboratory comparison test, Gansu Center for Disease Prevention and Control participated in the comparison test organized by China Center for Disease Prevention and Control continuously from 2007 to 2012. All of the measured values are within the scope of qualified, and the relative deviation of measured value in the entire comparison tests is range from -16.31% to 11.83%.The results show that the equipment for γ spectrum measurement works normally, the analysis methods used for radioactive nuclide measuring is correct and the data in issued test report is accurate and reliable. The ability of the γ spectrum analysis satisfies the requirements of China Metrology Accreditation and the occupational health technical service. (authors)

  17. Summary of aerosol code-comparison results for LWR aerosol containment tests LA1, LA2, and LA3

    International Nuclear Information System (INIS)

    Wright, A.L.; Wilson, J.H.; Arwood, P.C.

    1987-01-01

    The light-water reactor (LWR) aerosol containment experiments (LACE) are being performed in Richland, Washington, at the Hanford Engineering Development Laboratory under the leadership of an international project board and the Electric Power Research Institute. These tests have two objectives: (1) to investigate, at large scale, the inherent aerosol retention behavior in LWR containments under simulated severe accident conditions, and (2) to provide an experimental data base for validating aerosol behavior and thermal-hydraulic computer codes. Aerosol computer-code comparison activities for the LACE tests are being coordinated at the Oak Ridge National Laboratory. For each of the six experiments, pretest calculations (for code-to-code comparisons) and blind post-test calculations (for code-to-test data comparisons) are being performed. This paper presents a summary of the pretest aerosol-code results for tests LA1, LA2, and LA3

  18. Measuring the Consistency in Change in Hepatitis B Knowledge among Three Different Types of Tests: True/False, Multiple Choice, and Fill in the Blanks Tests.

    Science.gov (United States)

    Sahai, Vic; Demeyere, Petra; Poirier, Sheila; Piro, Felice

    1998-01-01

    The recall of information about Hepatitis B demonstrated by 180 seventh graders was tested with three test types: (1) short-answer; (2) true/false; and (3) multiple-choice. Short answer testing was the most reliable. Suggestions are made for the use of short-answer tests in evaluating student knowledge. (SLD)

  19. Deformable microparticles with multiple functions for drug delivery and device testing

    Science.gov (United States)

    Thula, Taili T.

    Since the HIV epidemic of the 1990s, researchers have attempted to develop a red blood cell analog. Even though some of these substitutes are now in Phase III of clinical trials, their use is limited by side effects and short half-life in the human body. As a result, there is still a need for an effective erythrocyte analog with minimum immunogenic and side effects, so that it can be used for multiple applications. Finding new approaches to develop more efficient blood substitutes will not only bring valuable advances in the clinical approach, but also in the area of in vitro testing of medical devices. We examined the feasibility of creating a deformable multi-functional, biodegradable, biocompatible particle for applications in drug delivery and device testing. As a preliminary evaluation, we synthesized different types of microcapsules using natural and synthetic polymers, various cross-linking agents, and diverse manufacturing techniques. After fully characterizing of each system, we determined the most promising red blood cell analog in terms of deformability, stability and toxicity. We also examined the encapsulation and release of bovine serum albumin (BSA) within these deformable particles. After removal of cross-linkers, zinc- and copper-alginate microparticles surrounded by multiple polyelectrolyte layers of chitosan oligosaccharide and alginate were deformable and remained stable under physiological pressures applied by the micropipette technique. In addition, multiple coatings decreased toxicity of heavy-metal crosslinked particles. BSA encapsulation and release from chitosan-alginate microspheres were contingent on the crosslinker and number of polyelectrolyte coatings, respectively. Further rheological studies are needed to determine how closely these particles simulate the behavior of erythrocytes. Also, studies on the encapsulation and release of different proteins, including hemoglobin, are needed to establish the desired controlled release of

  20. An open-source software program for performing Bonferroni and related corrections for multiple comparisons

    Directory of Open Access Journals (Sweden)

    Kyle Lesack

    2011-01-01

    Full Text Available Increased type I error resulting from multiple statistical comparisons remains a common problem in the scientific literature. This may result in the reporting and promulgation of spurious findings. One approach to this problem is to correct groups of P-values for "family-wide significance" using a Bonferroni correction or the less conservative Bonferroni-Holm correction or to correct for the "false discovery rate" with a Benjamini-Hochberg correction. Although several solutions are available for performing this correction through commercially available software there are no widely available easy to use open source programs to perform these calculations. In this paper we present an open source program written in Python 3.2 that performs calculations for standard Bonferroni, Bonferroni-Holm and Benjamini-Hochberg corrections.

  1. Combining morphometric evidence from multiple registration methods using dempster-shafer theory

    Science.gov (United States)

    Rajagopalan, Vidya; Wyatt, Christopher

    2010-03-01

    In tensor-based morphometry (TBM) group-wise differences in brain structure are measured using high degreeof- freedom registration and some form of statistical test. However, it is known that TBM results are sensitive to both the registration method and statistical test used. Given the lack of an objective model of group variation is it difficult to determine a best registration method for TBM. The use of statistical tests is also problematic given the corrections required for multiple testing and the notorius difficulty selecting and intepreting signigance values. This paper presents an approach to address both of these issues by combining multiple registration methods using Dempster-Shafer Evidence theory to produce belief maps of categorical changes between groups. This approach is applied to the comparison brain morphometry in aging, a typical application of TBM, using the determinant of the Jacobian as a measure of volume change. We show that the Dempster-Shafer combination produces a unique and easy to interpret belief map of regional changes between and within groups without the complications associated with hypothesis testing.

  2. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  3. Testing statistical significance scores of sequence comparison methods with structure similarity

    Directory of Open Access Journals (Sweden)

    Leunissen Jack AM

    2006-10-01

    Full Text Available Abstract Background In the past years the Smith-Waterman sequence comparison algorithm has gained popularity due to improved implementations and rapidly increasing computing power. However, the quality and sensitivity of a database search is not only determined by the algorithm but also by the statistical significance testing for an alignment. The e-value is the most commonly used statistical validation method for sequence database searching. The CluSTr database and the Protein World database have been created using an alternative statistical significance test: a Z-score based on Monte-Carlo statistics. Several papers have described the superiority of the Z-score as compared to the e-value, using simulated data. We were interested if this could be validated when applied to existing, evolutionary related protein sequences. Results All experiments are performed on the ASTRAL SCOP database. The Smith-Waterman sequence comparison algorithm with both e-value and Z-score statistics is evaluated, using ROC, CVE and AP measures. The BLAST and FASTA algorithms are used as reference. We find that two out of three Smith-Waterman implementations with e-value are better at predicting structural similarities between proteins than the Smith-Waterman implementation with Z-score. SSEARCH especially has very high scores. Conclusion The compute intensive Z-score does not have a clear advantage over the e-value. The Smith-Waterman implementations give generally better results than their heuristic counterparts. We recommend using the SSEARCH algorithm combined with e-values for pairwise sequence comparisons.

  4. Testing Mediation Using Multiple Regression and Structural Equation Modeling Analyses in Secondary Data

    Science.gov (United States)

    Li, Spencer D.

    2011-01-01

    Mediation analysis in child and adolescent development research is possible using large secondary data sets. This article provides an overview of two statistical methods commonly used to test mediated effects in secondary analysis: multiple regression and structural equation modeling (SEM). Two empirical studies are presented to illustrate the…

  5. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald; Liever, Peter; Nielsen, Tanner

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test, conducted at Marshall Space Flight Center. The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  6. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald K.; Liever, Peter A.

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test (SMAT), conducted at Marshall Space Flight Center (MSFC). The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  7. MCNP and GADRAS Comparisons

    International Nuclear Information System (INIS)

    Klasky, Marc Louis; Myers, Steven Charles; James, Michael R.; Mayo, Douglas R.

    2016-01-01

    To facilitate the timely execution of System Threat Reviews (STRs) for DNDO, and also to develop a methodology for performing STRs, LANL performed comparisons of several radiation transport codes (MCNP, GADRAS, and Gamma-Designer) that have been previously utilized to compute radiation signatures. While each of these codes has strengths, it is of paramount interest to determine the limitations of each of the respective codes and also to identify the most time efficient means by which to produce computational results, given the large number of parametric cases that are anticipated in performing STR's. These comparisons serve to identify regions of applicability for each code and provide estimates of uncertainty that may be anticipated. Furthermore, while performing these comparisons, examination of the sensitivity of the results to modeling assumptions was also examined. These investigations serve to enable the creation of the LANL methodology for performing STRs. Given the wide variety of radiation test sources, scenarios, and detectors, LANL calculated comparisons of the following parameters: decay data, multiplicity, device (n,γ) leakages, and radiation transport through representative scenes and shielding. This investigation was performed to understand potential limitations utilizing specific codes for different aspects of the STR challenges.

  8. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  9. Comparative Efficacy of Daratumumab Monotherapy and Pomalidomide Plus Low-Dose Dexamethasone in the Treatment of Multiple Myeloma: A Matching Adjusted Indirect Comparison.

    Science.gov (United States)

    Van Sanden, Suzy; Ito, Tetsuro; Diels, Joris; Vogel, Martin; Belch, Andrew; Oriol, Albert

    2018-03-01

    Daratumumab (a human CD38-directed monoclonal antibody) and pomalidomide (an immunomodulatory drug) plus dexamethasone are both relatively new treatment options for patients with heavily pretreated multiple myeloma. A matching adjusted indirect comparison (MAIC) was used to compare absolute treatment effects of daratumumab versus pomalidomide + low-dose dexamethasone (LoDex; 40 mg) on overall survival (OS), while adjusting for differences between the trial populations. The MAIC method reduces the risk of bias associated with naïve indirect comparisons. Data from 148 patients receiving daratumumab (16 mg/kg), pooled from the GEN501 and SIRIUS studies, were compared separately with data from patients receiving pomalidomide + LoDex in the MM-003 and STRATUS studies. The MAIC-adjusted hazard ratio (HR) for OS of daratumumab versus pomalidomide + LoDex was 0.56 (95% confidence interval [CI], 0.38-0.83; p  = .0041) for MM-003 and 0.51 (95% CI, 0.37-0.69; p  < .0001) for STRATUS. The treatment benefit was even more pronounced when the daratumumab population was restricted to pomalidomide-naïve patients (MM-003: HR, 0.33; 95% CI, 0.17-0.66; p  = .0017; STRATUS: HR, 0.41; 95% CI, 0.21-0.79; p  = .0082). An additional analysis indicated a consistent trend of the OS benefit across subgroups based on M-protein level reduction (≥50%, ≥25%, and <25%). The MAIC results suggest that daratumumab improves OS compared with pomalidomide + LoDex in patients with heavily pretreated multiple myeloma. This matching adjusted indirect comparison of clinical trial data from four studies analyzes the survival outcomes of patients with heavily pretreated, relapsed/refractory multiple myeloma who received either daratumumab monotherapy or pomalidomide plus low-dose dexamethasone. Using this method, daratumumab conferred a significant overall survival benefit compared with pomalidomide plus low-dose dexamethasone. In the absence of head-to-head trials, these

  10. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Exadaktylos, A. [Inselspital - University Hospital Bern (Switzerland). Dept. of Emergency Medicine; Klink, T. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-02-15

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  11. Development and tests of MCP based timing and multiplicity detector for MIPs

    Science.gov (United States)

    Feofilov, G.; Kondratev, V.; Stolyarov, O.; Tulina, T.; Valiev, F.; Vinogradov, L.

    2017-01-01

    We present summary of technological developments and tests of the MCP based large area detector aimed at precise timing and charged particles multiplicity measurements. Results obtained in course of these developments of isochronous (simultaneity) precise signal readout, passive summation of 1 ns signals, fast (1 GHz) front-end electronics, miniature vacuum systems, etc. could be potentially interesting for a number of future applications in different fields.

  12. Statistical Multiplicity in Systematic Reviews of Anaesthesia Interventions: A Quantification and Comparison between Cochrane and Non-Cochrane Reviews

    DEFF Research Database (Denmark)

    Imberger, Georgina; Vejlby, Alexandra Hedvig Damgaard; Hansen, Sara Bohnstedt

    2011-01-01

    Systematic reviews with meta-analyses often contain many statistical tests. This multiplicity may increase the risk of type I error. Few attempts have been made to address the problem of statistical multiplicity in systematic reviews. Before the implications are properly considered, the size...... of systematic reviews and aimed to assess whether this quantity is different in Cochrane and non-Cochrane reviews....... of the issue deserves clarification. Because of the emphasis on bias evaluation and because of the editorial processes involved, Cochrane reviews may contain more multiplicity than their non-Cochrane counterparts. This study measured the quantity of statistical multiplicity present in a population...

  13. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  14. A Comparison of Combustion Dynamics for Multiple 7-Point Lean Direct Injection Combustor Configurations

    Science.gov (United States)

    Tacina, K. M.; Hicks, Y. R.

    2017-01-01

    The combustion dynamics of multiple 7-point lean direct injection (LDI) combustor configurations are compared. LDI is a fuel-lean combustor concept for aero gas turbine engines in which multiple small fuel-air mixers replace one traditionally-sized fuel-air mixer. This 7-point LDI configuration has a circular cross section, with a center (pilot) fuel-air mixer surrounded by six outer (main) fuel-air mixers. Each fuel-air mixer consists of an axial air swirler followed by a converging-diverging venturi. A simplex fuel injector is inserted through the center of the air swirler, with the fuel injector tip located near the venturi throat. All 7 fuel-air mixers are identical except for the swirler blade angle, which varies with the configuration. Testing was done in a 5-atm flame tube with inlet air temperatures from 600 to 800 F and equivalence ratios from 0.4 to 0.7. Combustion dynamics were measured using a cooled PCB pressure transducer flush-mounted in the wall of the combustor test section.

  15. Compressed Sensing mm-Wave SAR for Non-Destructive Testing Applications Using Multiple Weighted Side Information

    Directory of Open Access Journals (Sweden)

    Mathias Becquaert

    2018-05-01

    Full Text Available This work explores an innovative strategy for increasing the efficiency of compressed sensing applied on mm-wave SAR sensing using multiple weighted side information. The approach is tested on synthetic and on real non-destructive testing measurements performed on a 3D-printed object with defects while taking advantage of multiple previous SAR images of the object with different degrees of similarity. The tested algorithm attributes autonomously weights to the side information at two levels: (1 between the components inside the side information and (2 between the different side information. The reconstruction is thereby almost immune to poor quality side information while exploiting the relevant components hidden inside the added side information. The presented results prove that, in contrast to common compressed sensing, good SAR image reconstruction is achieved at subsampling rates far below the Nyquist rate. Moreover, the algorithm is shown to be much more robust for low quality side information compared to coherent background subtraction.

  16. Ordinal Welfare Comparisons with Multiple Discrete Indicators

    DEFF Research Database (Denmark)

    Arndt, Channing; Distante, Roberta; Hussain, M. Azhar

    We develop an ordinal method for making welfare comparisons between populations with multidimensional discrete well-being indicators observed at the micro level. The approach assumes that, for each well-being indicator, the levels can be ranked from worse to better; however, no assumptions are made...

  17. Performance on Paced Auditory Serial Addition Test and cerebral blood flow in multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, M.; Steen, C.; Hoogduin, J. M.; van Osch, M. J. P.; Fierens, Y.; Cambron, M.; Koch, M. W.; De Keyser, J.

    BackgroundTo assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). MethodsNormal

  18. The "None of the Above" Option in Multiple-Choice Testing: An Experimental Study

    Science.gov (United States)

    DiBattista, David; Sinnige-Egger, Jo-Anne; Fortuna, Glenda

    2014-01-01

    The authors assessed the effects of using "none of the above" as an option in a 40-item, general-knowledge multiple-choice test administered to undergraduate students. Examinees who selected "none of the above" were given an incentive to write the correct answer to the question posed. Using "none of the above" as the…

  19. CSA: An efficient algorithm to improve circular DNA multiple alignment

    Directory of Open Access Journals (Sweden)

    Pereira Luísa

    2009-07-01

    Full Text Available Abstract Background The comparison of homologous sequences from different species is an essential approach to reconstruct the evolutionary history of species and of the genes they harbour in their genomes. Several complete mitochondrial and nuclear genomes are now available, increasing the importance of using multiple sequence alignment algorithms in comparative genomics. MtDNA has long been used in phylogenetic analysis and errors in the alignments can lead to errors in the interpretation of evolutionary information. Although a large number of multiple sequence alignment algorithms have been proposed to date, they all deal with linear DNA and cannot handle directly circular DNA. Researchers interested in aligning circular DNA sequences must first rotate them to the "right" place using an essentially manual process, before they can use multiple sequence alignment tools. Results In this paper we propose an efficient algorithm that identifies the most interesting region to cut circular genomes in order to improve phylogenetic analysis when using standard multiple sequence alignment algorithms. This algorithm identifies the largest chain of non-repeated longest subsequences common to a set of circular mitochondrial DNA sequences. All the sequences are then rotated and made linear for multiple alignment purposes. To evaluate the effectiveness of this new tool, three different sets of mitochondrial DNA sequences were considered. Other tests considering randomly rotated sequences were also performed. The software package Arlequin was used to evaluate the standard genetic measures of the alignments obtained with and without the use of the CSA algorithm with two well known multiple alignment algorithms, the CLUSTALW and the MAVID tools, and also the visualization tool SinicView. Conclusion The results show that a circularization and rotation pre-processing step significantly improves the efficiency of public available multiple sequence alignment

  20. Estimating the Proportion of True Null Hypotheses in Multiple Testing Problems

    Directory of Open Access Journals (Sweden)

    Oluyemi Oyeniran

    2016-01-01

    Full Text Available The problem of estimating the proportion, π0, of the true null hypotheses in a multiple testing problem is important in cases where large scale parallel hypotheses tests are performed independently. While the problem is a quantity of interest in its own right in applications, the estimate of π0 can be used for assessing or controlling an overall false discovery rate. In this article, we develop an innovative nonparametric maximum likelihood approach to estimate π0. The nonparametric likelihood is proposed to be restricted to multinomial models and an EM algorithm is also developed to approximate the estimate of π0. Simulation studies show that the proposed method outperforms other existing methods. Using experimental microarray datasets, we demonstrate that the new method provides satisfactory estimate in practice.

  1. Comparison of a Ring On-Chip Network and a Code-Division Multiple-Access On-Chip Network

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2007-01-01

    Full Text Available Two network-on-chip (NoC designs are examined and compared in this paper. One design applies a bidirectional ring connection scheme, while the other design applies a code-division multiple-access (CDMA connection scheme. Both of the designs apply globally asynchronous locally synchronous (GALS scheme in order to deal with the issue of transferring data in a multiple-clock-domain environment of an on-chip system. The two NoC designs are compared with each other by their network structures, data transfer principles, network node structures, and their asynchronous designs. Both the synchronous and the asynchronous designs of the two on-chip networks are realized using a hardware-description language (HDL in order to make the entire designs suit the commonly used synchronous design tools and flow. The performance estimation and comparison of the two NoC designs which are based on the HDL realizations are addressed. By comparing the two NoC designs, the advantages and disadvantages of applying direct connection and CDMA connection schemes in an on-chip communication network are discussed.

  2. Near-field heat transfer at the spent fuel test-climax: a comparison of measurements and calculations

    International Nuclear Information System (INIS)

    Patrick, W.C.; Montan, D.N.; Ballou, L.B.

    1981-01-01

    The Spent Fuel Test in the Climax granitic stock at the DOE Nevada Test Site is a test of the feasibility of storage and retrieval of spent nuclear reactor fuel in a deep geologic environment. Eleven spent fuel elements, together with six thermally identical electrical resistance heaters and 20 peripheral guard heaters, are emplaced 420 m below surface in a three-drift test array. This array was designed to simulate the near-field effects of thousands of canisters of nuclear waste and to evaluate the effects of heat alone, and heat plus ionizing radiation on the rock. Thermal calculations and measurements are conducted to determine thermal transport from the spent fuel and electrical resistance heaters. Calculations associated with the as-built Spent Fuel Test geometry and thermal source histories are presented and compared with thermocouple measurements made throughout the test array. Comparisons in space begin at the spent fuel canister and include the first few metres outside the test array. Comparisons in time begin at emplacement and progress through the first year of thermal loading in this multi-year test

  3. Analysing earthquake slip models with the spatial prediction comparison test

    KAUST Repository

    Zhang, L.; Mai, Paul Martin; Thingbaijam, Kiran Kumar; Razafindrakoto, H. N. T.; Genton, Marc G.

    2014-01-01

    Earthquake rupture models inferred from inversions of geophysical and/or geodetic data exhibit remarkable variability due to uncertainties in modelling assumptions, the use of different inversion algorithms, or variations in data selection and data processing. A robust statistical comparison of different rupture models obtained for a single earthquake is needed to quantify the intra-event variability, both for benchmark exercises and for real earthquakes. The same approach may be useful to characterize (dis-)similarities in events that are typically grouped into a common class of events (e.g. moderate-size crustal strike-slip earthquakes or tsunamigenic large subduction earthquakes). For this purpose, we examine the performance of the spatial prediction comparison test (SPCT), a statistical test developed to compare spatial (random) fields by means of a chosen loss function that describes an error relation between a 2-D field (‘model’) and a reference model. We implement and calibrate the SPCT approach for a suite of synthetic 2-D slip distributions, generated as spatial random fields with various characteristics, and then apply the method to results of a benchmark inversion exercise with known solution. We find the SPCT to be sensitive to different spatial correlations lengths, and different heterogeneity levels of the slip distributions. The SPCT approach proves to be a simple and effective tool for ranking the slip models with respect to a reference model.

  4. Analysing earthquake slip models with the spatial prediction comparison test

    KAUST Repository

    Zhang, L.

    2014-11-10

    Earthquake rupture models inferred from inversions of geophysical and/or geodetic data exhibit remarkable variability due to uncertainties in modelling assumptions, the use of different inversion algorithms, or variations in data selection and data processing. A robust statistical comparison of different rupture models obtained for a single earthquake is needed to quantify the intra-event variability, both for benchmark exercises and for real earthquakes. The same approach may be useful to characterize (dis-)similarities in events that are typically grouped into a common class of events (e.g. moderate-size crustal strike-slip earthquakes or tsunamigenic large subduction earthquakes). For this purpose, we examine the performance of the spatial prediction comparison test (SPCT), a statistical test developed to compare spatial (random) fields by means of a chosen loss function that describes an error relation between a 2-D field (‘model’) and a reference model. We implement and calibrate the SPCT approach for a suite of synthetic 2-D slip distributions, generated as spatial random fields with various characteristics, and then apply the method to results of a benchmark inversion exercise with known solution. We find the SPCT to be sensitive to different spatial correlations lengths, and different heterogeneity levels of the slip distributions. The SPCT approach proves to be a simple and effective tool for ranking the slip models with respect to a reference model.

  5. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  6. Agreement analysis comparing iPad LCVA and Sloan testing in multiple sclerosis patients.

    Science.gov (United States)

    Sattarnezhad, Neda; Farrow, Samantha; Kimbrough, Dorlan; Glanz, Bonnie; Healy, Brian; Chitnis, Tanuja

    2017-06-01

    Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting. To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients. A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test. For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p iPad-based LCVA test shows good agreement with Sloan testing in MS patients.

  7. Improvements in cognition, quality of life, and physical performance with clinical Pilates in multiple sclerosis: a randomized controlled trial.

    Science.gov (United States)

    Küçük, Fadime; Kara, Bilge; Poyraz, Esra Çoşkuner; İdiman, Egemen

    2016-03-01

    [Purpose] The aim of this study was to determine the effects of clinical Pilates in multiple sclerosis patients. [Subjects and Methods] Twenty multiple sclerosis patients were enrolled in this study. The participants were divided into two groups as the clinical Pilates and control groups. Cognition (Multiple Sclerosis Functional Composite), balance (Berg Balance Scale), physical performance (timed performance tests, Timed up and go test), tiredness (Modified Fatigue Impact scale), depression (Beck Depression Inventory), and quality of life (Multiple Sclerosis International Quality of Life Questionnaire) were measured before and after treatment in all participants. [Results] There were statistically significant differences in balance, timed performance, tiredness and Multiple Sclerosis Functional Composite tests between before and after treatment in the clinical Pilates group. We also found significant differences in timed performance tests, the Timed up and go test and the Multiple Sclerosis Functional Composite between before and after treatment in the control group. According to the difference analyses, there were significant differences in Multiple Sclerosis Functional Composite and Multiple Sclerosis International Quality of Life Questionnaire scores between the two groups in favor of the clinical Pilates group. There were statistically significant clinical differences in favor of the clinical Pilates group in comparison of measurements between the groups. Clinical Pilates improved cognitive functions and quality of life compared with traditional exercise. [Conclusion] In Multiple Sclerosis treatment, clinical Pilates should be used as a holistic approach by physical therapists.

  8. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    Science.gov (United States)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  9. Methods for significance testing of categorical covariates in logistic regression models after multiple imputation: power and applicability analysis

    NARCIS (Netherlands)

    Eekhout, I.; Wiel, M.A. van de; Heymans, M.W.

    2017-01-01

    Background. Multiple imputation is a recommended method to handle missing data. For significance testing after multiple imputation, Rubin’s Rules (RR) are easily applied to pool parameter estimates. In a logistic regression model, to consider whether a categorical covariate with more than two levels

  10. A numerical comparison between the multiple-scales and finite-element solution for sound propagation in lined flow ducts

    NARCIS (Netherlands)

    Rienstra, S.W.; Eversman, W.

    2001-01-01

    An explicit, analytical, multiple-scales solution for modal sound transmission through slowly varying ducts with mean flow and acoustic lining is tested against a numerical finite-element solution solving the same potential flow equations. The test geometry taken is representative of a high-bypass

  11. Multiple Intelligences Profiles of Children with Attention Deficit and Hyperactivity Disorder in Comparison with Nonattention Deficit and Hyperactivity Disorder

    OpenAIRE

    Najafi, Mostafa; Akouchekian, Shahla; Ghaderi, Alireza; Mahaki, Behzad; Rezaei, Mariam

    2017-01-01

    Background: Attention deficit and hyperactivity disorder (ADHD) is a common psychological problem during childhood. This study aimed to evaluate multiple intelligences profiles of children with ADHD in comparison with non-ADHD. Materials and Methods: This cross-sectional descriptive analytical study was done on 50 children of 6–13 years old in two groups of with and without ADHD. Children with ADHD were referred to Clinics of Child and Adolescent Psychiatry, Isfahan University of Medical Scie...

  12. The effects of multiple features of alternatively spliced exons on the KA/KS ratio test

    Directory of Open Access Journals (Sweden)

    Chen Feng-Chi

    2006-05-01

    Full Text Available Abstract Background The evolution of alternatively spliced exons (ASEs is of primary interest because these exons are suggested to be a major source of functional diversity of proteins. Many exon features have been suggested to affect the evolution of ASEs. However, previous studies have relied on the KA/KS ratio test without taking into consideration information sufficiency (i.e., exon length > 75 bp, cross-species divergence > 5% of the studied exons, leading to potentially biased interpretations. Furthermore, which exon feature dominates the results of the KA/KS ratio test and whether multiple exon features have additive effects have remained unexplored. Results In this study, we collect two different datasets for analysis – the ASE dataset (which includes lineage-specific ASEs and conserved ASEs and the ACE dataset (which includes only conserved ASEs. We first show that information sufficiency can significantly affect the interpretation of relationship between exons features and the KA/KS ratio test results. After discarding exons with insufficient information, we use a Boolean method to analyze the relationship between test results and four exon features (namely length, protein domain overlapping, inclusion level, and exonic splicing enhancer (ESE frequency for the ASE dataset. We demonstrate that length and protein domain overlapping are dominant factors, and they have similar impacts on test results of ASEs. In addition, despite the weak impacts of inclusion level and ESE motif frequency when considered individually, combination of these two factors still have minor additive effects on test results. However, the ACE dataset shows a slightly different result in that inclusion level has a marginally significant effect on test results. Lineage-specific ASEs may have contributed to the difference. Overall, in both ASEs and ACEs, protein domain overlapping is the most dominant exon feature while ESE frequency is the weakest one in affecting

  13. Passive neutron-multiplication measurements

    International Nuclear Information System (INIS)

    Zolnay, A.S.; Barnett, C.S.; Spracklen, H.P.

    1982-01-01

    We have developed an instrument to measure neutron multiplication by statistical analysis of the timing of neutrons emitted from fissionable material. This instrument is capable of repeated analysis of the same recorded data with selected algorithms, graphical displays showing statistical properties of the data, and preservation of raw data on disk for future comparisons. In our measurements we have made a comparison of the covariance to mean and Feynman variance to mean analysis algorithms to show that the covariance avoids a bias term and measures directly the effect due to the presence of neutron chains. A spherical assembly of enriched uranium shells and acrylic resin reflector/moderator components used for the measurements is described. Preliminary experimental results of the Feynman variance to mean measurements show the expected correlation with assembly multiplication

  14. Comparison of theoretical and test results on shear wall seismic response

    International Nuclear Information System (INIS)

    Gantenbein, F.; Wang, F.; Dalbera, J.

    1991-01-01

    As reinforced concrete shear walls are important resisting components of buildings in nuclear power facilities, it is important to study their ultimate behavior under dynamic loading. An experimental and analytical work has been undertaken on shear walls with and without openings, in order to develop and validate their model. This paper is related to the walls without openings. While pretest calculations have already been reported (Wang and al. 1989) and the test results are given in Gantenbein and al. 1991, this paper is mainly related to the comparison of test and calculation results on the wall initial stiffness and the time history of the wall motion

  15. The Los Alamos Gap Stick Test

    Science.gov (United States)

    Preston, Daniel; Hill, Larry; Johnson, Carl

    2015-06-01

    In this paper we describe a novel shock sensitivity test, the Gap Stick Test, which is a generalized variant of the ubiquitous Gap Test. Despite the popularity of the Gap Test, it has some disadvantages: multiple tests must be fired to obtain a single metric, and many tests must be fired to obtain its value to high precision and confidence. Our solution is a test wherein multiple gap tests are joined in series to form a rate stick. The complex re-initiation character of the traditional gap test is thereby retained, but the propagation speed is steady when measured at periodic intervals, and initiation delay in individual segments acts to decrement the average speed. We measure the shock arrival time before and after each inert gap, and compute the average detonation speed through the HE alone (discounting the gap thicknesses). We perform tests for a range of gap thicknesses. We then plot the aforementioned propagation speed as a function of gap thickness. The resulting curve has the same basic structure as a Diameter Effect (DE) curve, and (like the DE curve) terminates at a failure point. Comparison between experiment and hydrocode calculations using ALE3D and the Ignition and Growth reactive burn model calibrated for short duration shock inputs in PBX 9501 is discussed.

  16. The Relationship of Deep and Surface Study Approaches on Factual and Applied Test-Bank Multiple-Choice Question Performance

    Science.gov (United States)

    Yonker, Julie E.

    2011-01-01

    With the advent of online test banks and large introductory classes, instructors have often turned to textbook publisher-generated multiple-choice question (MCQ) exams in their courses. Multiple-choice questions are often divided into categories of factual or applied, thereby implicating levels of cognitive processing. This investigation examined…

  17. Comparison of three flaw-location methods for automated ultrasonic testing

    International Nuclear Information System (INIS)

    Seiger, H.

    1982-01-01

    Two well-known methods for locating flaws by measurement of the transit time of ultrasonic pulses are examined theoretically. It is shown that neither is sufficiently reliable for use in automated ultrasonic testing. A third method, which takes into account the shape of the sound field from the probe and the uncertainty in measurement of probe-flaw distance and probe position, is introduced. An experimental comparison of the three methods indicates that use of the advanced method results in more accurate location of flaws. (author)

  18. A Bayesian decision procedure for testing multiple hypotheses in DNA microarray experiments.

    Science.gov (United States)

    Gómez-Villegas, Miguel A; Salazar, Isabel; Sanz, Luis

    2014-02-01

    DNA microarray experiments require the use of multiple hypothesis testing procedures because thousands of hypotheses are simultaneously tested. We deal with this problem from a Bayesian decision theory perspective. We propose a decision criterion based on an estimation of the number of false null hypotheses (FNH), taking as an error measure the proportion of the posterior expected number of false positives with respect to the estimated number of true null hypotheses. The methodology is applied to a Gaussian model when testing bilateral hypotheses. The procedure is illustrated with both simulated and real data examples and the results are compared to those obtained by the Bayes rule when an additive loss function is considered for each joint action and the generalized loss 0-1 function for each individual action. Our procedure significantly reduced the percentage of false negatives whereas the percentage of false positives remains at an acceptable level.

  19. Using the Coefficient of Determination "R"[superscript 2] to Test the Significance of Multiple Linear Regression

    Science.gov (United States)

    Quinino, Roberto C.; Reis, Edna A.; Bessegato, Lupercio F.

    2013-01-01

    This article proposes the use of the coefficient of determination as a statistic for hypothesis testing in multiple linear regression based on distributions acquired by beta sampling. (Contains 3 figures.)

  20. Multiple ionization of noble gases by 2.0 MeV proton impact: comparison with equi-velocity electron impact ionization

    International Nuclear Information System (INIS)

    Melo, W.S.; Santos, A.C.F.; Sant'Anna, M.M.; Sigaud, G.M.; Montenegro, E.C.

    2002-01-01

    Absolute single- and multiple-ionization cross sections of rare gases (He, Ne, Ar, Kr and Xe) have been measured for collisions with 2.0 MeV p + . A comparison is made with equi-velocity electron impact ionization cross sections as well as with the available proton impact data. For the light rare gases the single-ionization cross sections are essentially the same for both proton and electron impacts, but increasing differences appear for the heavier targets. (author). Letter-to-the-editor

  1. Depression and pain: testing of serial multiple mediators.

    Science.gov (United States)

    Wongpakaran, Tinakon; Wongpakaran, Nahathai; Tanchakvaranont, Sitthinant; Bookkamana, Putipong; Pinyopornpanish, Manee; Wannarit, Kamonporn; Satthapisit, Sirina; Nakawiro, Daochompu; Hiranyatheb, Thanita; Thongpibul, Kulvadee

    2016-01-01

    Despite the fact that pain is related to depression, few studies have been conducted to investigate the variables that mediate between the two conditions. In this study, the authors explored the following mediators: cognitive function, self-sacrificing interpersonal problems, and perception of stress, and the effects they had on pain symptoms among patients with depressive disorders. An analysis was performed on the data of 346 participants with unipolar depressive disorders. The 17-item Hamilton Depression Rating Scale, Mini-Mental State Examination, the pain subscale of the health-related quality of life (SF-36), the self-sacrificing subscale of the Inventory of Interpersonal Problems, and the Perceived Stress Scale were used. Parallel multiple mediator and serial multiple mediator models were used. An alternative model regarding the effect of self-sacrificing on pain was also proposed. Perceived stress, self-sacrificing interpersonal style, and cognitive function were found to significantly mediate the relationship between depression and pain, while controlling for demographic variables. The total effect of depression on pain was significant. This model, with an additional three mediators, accounted for 15% of the explained variance in pain compared to 9% without mediators. For the alternative model, after controlling for the mediators, a nonsignificant total direct effect level of self-sacrificing was found, suggesting that the effect of self-sacrificing on pain was based only on an indirect effect and that perceived stress was found to be the strongest mediator. Serial mediation may help us to see how depression and pain are linked and what the fundamental mediators are in the chain. No significant, indirect effect of self-sacrificing on pain was observed, if perceived stress was not part of the depression and/or cognitive function mediational chain. The results shown here have implications for future research, both in terms of testing the model and in

  2. Hypothalamic digoxin, hemispheric chemical dominance, and oncogenesis: evidence from multiple myeloma.

    Science.gov (United States)

    Kurup, Ravi Kumar; Kurup, Paramesware Achutha

    2003-12-01

    This study assessed the changes in the isoprenoid pathway and its metabolites digoxin, dolichol, and ubiquinone in multiple myeloma. The isoprenoid pathway and digoxin status were also studied for comparison in individuals of differing hemispheric dominance to find out the rote of cerebral dominance in the genesis of multiple myeloma and neoplasms. The following parameters were assessed: isoprenoid pathway metabolites, tyrosine and tryptophan catabolites, glycoconjugate metabolism, RBC membrane composition, and free radical metabolism--in multiple myeloma, as well as in individuals of differing hemispheric dominance. There was elevation in plasma HMG CoA reductase activity, serum digoxin, and dolichol, and a reduction in RBC membrane Na(+)-K+ ATPase activity, serum ubiquinone, and magnesium levels. Serum tryptophan, serotonin, nicotine, strychnine, and quinolinic acid were elevated, while tyrosine, dopamine, noradrenaline, and morphine were decreased. The total serum glycosaminoglycans and glycosaminoglycan fractions, the activity of GAG degrading enzymes and glycohydrolases, carbohydrate residues of glycoproteins, and serum glycolipids were elevated. The RBC membrane glycosaminoglycans, hexose, and fucose residues of glycoproteins, cholesterol, and phospholipids were reduced. The activity of all free-radical scavenging enzymes, concentration of glutathione, iron binding capacity, and ceruloplasmin decreased significantly, while the concentration of lipid peroxidation products and nitric oxide increased. Hyperdigoxinemia-related altered intracellular Ca++/Mg++ ratios mediated oncogene activation, dolichol-induced altered glycoconjugate metabolism, and ubiquinone deficiency-related mitochondrial dysfunction can contribute to the pathogenesis of multiple myeloma. The biochemical patterns obtained in multiple myeloma are similar to those obtained in left-handed/right hemispheric chemically dominant individuals by the dichotic listening test. But all the patients with

  3. Comparison of DOE-2 with measurements in the Pala Test houses

    Energy Technology Data Exchange (ETDEWEB)

    Meldem, R.; Winkelmann, F.

    1995-07-01

    The predictions of the DOE-2 program for building energy analysis have been compared with measurements in the Pala test houses near San Diego. This work is part of the California Institute for Energy Efficiency {open_quotes}Alternatives to Compressor Cooling in California Transition Zones{close_quotes} project in which DOE-2 is being used for parametric analysis of cooling strategies that reduce peak electrical power in hot, dry climates. To establish the validity of DOE-2 for this kind of analysis the program was compared with room air temperature measurements in a {open_quotes}low-mass{close_quotes} house with conventional insulated study wall construction and a {open_quotes}high-mass{close_quotes} house with insulated concrete walls. To test different aspects of the DOE-2 calculation, four different unconditioned thermal configurations of these houses were considered: unshaded windows, shaded windows, white exterior surfaces, and forced night ventilation. In all cases DOE-2 agreed well with the air temperature measurements, with a mean deviation between simulation and measurement ranging from 0.2 to 1.0 K depending on configuration and type of house. Using a development version of DOE-2 comparisons with inside surface temperature measurements were also made. These comparisons also showed good agreement.

  4. A new powerful non-parametric two-stage approach for testing multiple phenotypes in family-based association studies

    NARCIS (Netherlands)

    Lange, C; Lyon, H; DeMeo, D; Raby, B; Silverman, EK; Weiss, ST

    2003-01-01

    We introduce a new powerful nonparametric testing strategy for family-based association studies in which multiple quantitative traits are recorded and the phenotype with the strongest genetic component is not known prior to the analysis. In the first stage, using a population-based test based on the

  5. A comparison of in vitro tests and a faecal egg count reduction test in detecting anthelmintic resistance in horse strongyles

    DEFF Research Database (Denmark)

    Craven, J.; Bjørn, H.; Barnes, E.H.

    1999-01-01

    This study reports a comparison between faecal egg count reduction test (FECRT), egg hatch assay (EHA) and larval development assay (LDA) for detecting anthelmintic resistance in equine strongyles. Resistance to benzimidazoles was demonstrated in 33 of 42 (79%) farms tested by FECRT and in 32 (62......%) of the 52 farms tested by EHA. As the reference strain used was not fully susceptible to benzimidazoles it was not possible to determine the level of resistance by LDA. Pyrantel resistance was indicated on three of 15 farms by faecal egg count reduction. Resistance was also indicated by LDA for one...

  6. Diagnostic utility of the glucagon stimulation test in comparison to the insulin tolerance test in patients following pituitary surgery

    DEFF Research Database (Denmark)

    Berg, Christian; Meinel, Timo; Lahner, Harald

    2009-01-01

    OBJECTIVE: The glucagon stimulation test (GST) like the insulin tolerance test (ITT) stimulates both ACTH and GH secretion. However, there are limited data with modern assays on sensitivity and specificity for GST in comparison to ITT. The aim of this study was to evaluate the diagnostic utility......). Receiver-operating characteristic (ROC) analysis was performed to identify the thresholds for GST. RESULTS: In ITT, 18/49 cases were classified as AI. ROC analysis revealed a peak cortisol value >599 nmol/l in GST for adrenal sufficiency with 100% specificity and 32% sensitivity, and a peak cortisol

  7. Testing for multiple invasion routes and source populations for the invasive brown treesnake (Boiga irregularis) on Guam: implications for pest management

    Science.gov (United States)

    Richmond, Jonathan Q.; Wood, Dustin A.; Stanford, James W.; Fisher, Robert N.

    2014-01-01

    The brown treesnake (Boiga irregularis) population on the Pacific island of Guam has reached iconic status as one of the most destructive invasive species of modern times, yet no published works have used genetic data to identify a source population. We used DNA sequence data from multiple genetic markers and coalescent-based phylogenetic methods to place the Guam population within the broader phylogeographic context of B. irregularis across its native range and tested whether patterns of genetic variation on the island are consistent with one or multiple introductions from different source populations. We also modeled a series of demographic scenarios that differed in the effective size and duration of a population bottleneck immediately following the invasion on Guam, and measured the fit of these simulations to the observed data using approximate Bayesian computation. Our results exclude the possibility of serial introductions from different source populations, and instead verify a single origin from the Admiralty Archipelago off the north coast of Papua New Guinea. This finding is consistent with the hypothesis thatB. irregularis was accidentally transported to Guam during military relocation efforts at the end of World War II. Demographic model comparisons suggest that multiple snakes were transported to Guam from the source locality, but that fewer than 10 individuals could be responsible for establishing the population. Our results also provide evidence that low genetic diversity stemming from the founder event has not been a hindrance to the ecological success of B. irregularis on Guam, and at the same time offers a unique ‘genetic opening’ to manage snake density using classical biological approaches.

  8. Comparison groups on bills: Automated, personalized energy information

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, Maithili; Kempton, Willett; Payne, Christopher

    2006-07-01

    A program called ``Innovative Billing?? has been developed to provide individualized energy information for a mass audience?the entireresidential customer base of an electric or gas utility. Customers receive a graph on the bill that compares that customer?s consumption with othersimilar customers for the same month. The program aims to stimulate customers to make ef?ciency improvements. To group as many as severalmillion customers into small ``comparison groups??, an automated method must be developed drawing solely from the data available to the utility.This paper develops and applies methods to compare the quality of resulting comparison groups.A data base of 114,000 customers from a utility billing system was used to evaluate Innovative Billing comparison groups, comparing fouralternative criteria: house characteristics (?oor area, housing type, and heating fuel); street; meter read route; billing cycle. Also, customers wereinterviewed to see what forms of comparison graphs made most sense and led to fewest errors of interpretation. We ?nd that good qualitycomparison groups result from using street name, meter book, or multiple house characteristics. Other criteria we tested, such as entire cycle, entiremeter book, or single house characteristics such as ?oor area, resulted in poor quality comparison groups. This analysis provides a basis forchoosing comparison groups based on extensive user testing and statistical analysis. The result is a practical set of guidelines that can be used toimplement realistic, inexpensive innovative billing for the entire customer base of an electric or gas utility.

  9. Double-multiple streamtube model for Darrieus in turbines

    Science.gov (United States)

    Paraschivoiu, I.

    1981-01-01

    An analytical model is proposed for calculating the rotor performance and aerodynamic blade forces for Darrieus wind turbines with curved blades. The method of analysis uses a multiple-streamtube model, divided into two parts: one modeling the upstream half-cycle of the rotor and the other, the downstream half-cycle. The upwind and downwind components of the induced velocities at each level of the rotor were obtained using the principle of two actuator disks in tandem. Variation of the induced velocities in the two parts of the rotor produces larger forces in the upstream zone and smaller forces in the downstream zone. Comparisons of the overall rotor performance with previous methods and field test data show the important improvement obtained with the present model. The calculations were made using the computer code CARDAA developed at IREQ. The double-multiple streamtube model presented has two major advantages: it requires a much shorter computer time than the three-dimensional vortex model and is more accurate than multiple-streamtube model in predicting the aerodynamic blade loads.

  10. Comparison of constant-rate pumping test and slug interference test results at the Hanford Site B pond multilevel test facility

    International Nuclear Information System (INIS)

    Spane, F.A. Jr.; Thorne, P.D.

    1995-10-01

    Pacific Northwest Laboratory (PNL), as part of the Hanford Site Ground-Water Surveillance Project, is responsible for monitoring the movement and fate of contamination within the unconfined aquifer to ensure that public health and the environment are protected. To support the monitoring and assessment of contamination migration on the Hanford Site, a sitewide 3-dimensional groundwater flow model is being developed. Providing quantitative hydrologic property data is instrumental in development of the 3-dimensional model. Multilevel monitoring facilities have been installed to provide detailed, vertically distributed hydrologic characterization information for the Hanford Site unconfined aquifer. In previous reports, vertically distributed water-level and hydrochemical data obtained over time from these multi-level monitoring facilities have been evaluated and reported. This report describes the B pond facility in Section 2.0. It also provides analysis results for a constant-rate pumping test (Section 3.0) and slug interference test (Section 4.0) that were conducted at a multilevel test facility located near B Pond (see Figure 1. 1) in the central part of the Hanford Site. A hydraulic test summary (Section 5.0) that focuses on the comparison of hydraulic property estimates obtained using the two test methods is also presented. Reference materials are listed in Section 6.0

  11. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  12. Assessment of SPACE code for multiple failure accident: 1% Cold Leg Break LOCA with HPSI failure at ATLAS Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Lee, Seung Wook; Kim, Kyung-Doo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Design extension conditions (DECs) is a popular key issue after the Fukushima accident. In a viewpoint of the reinforcement of the defense in depth concept, a high-risk multiple failure accident should be reconsidered. The target scenario of ATLAS A5.1 test was LSTF (Large Scale Test Facility) SB-CL-32 test, a 1% SBLOCA with total failure of high pressure safety injection (HPSI) system of emergency core cooling system (ECCS) and secondary side depressurization as the accident management (AM) action, as a counterpart test. As the needs to prepare the DEC accident because of a multiple failure of the present NPPs are emphasized, the capability of SPACE code, just like other system analysis code, is required to expand the DEC area. The objectives of this study is to validate the capability of SPACE code for a DEC scenario, which represents multiple failure accident like as a SBLOCA with HPSI fail. Therefore, the ATLAS A5.1 test scenario was chosen. As the needs to prepare the DEC accident because of a multiple failure of operating NPPs are emphasized, the capability of SPACE code is needed to expand the DEC area. So the capability of SPACE code was validated for one of a DEC scenario. The target scenario was selected as the ATLAS A5.1 test, which is a 1% SBLOCA with total failure of HPSI system of ECCS and secondary side depressurization. Through the sensitivity study on discharge coefficient of break flow, the best fit of integrated mass was found. Using the coefficient, the ATLAS A5.1 test was analyzed using the SPACE code. The major thermal hydraulic parameters such as the system pressure, temperatures were compared with the test and have a good agreement. Through the simulation, it was concluded that the SPACE code can effectively simulate one of multiple failure accidents like as SBLOCA with HPSI failure accident.

  13. Logisnet: A tool for multimethod, multiple soil layers slope stability analysis

    Science.gov (United States)

    Legorreta Paulin, G.; Bursik, M.

    2009-05-01

    Shallow landslides and slope failures have been studied from several points of view (inventory, heuristic, statistic, and deterministic). In particular, numerous methods embedded in Geographic Information Systems (GIS) applications have been developed to assess slope stability. However, little work has been done on the systematic comparison of different techniques and the incorporation of vertical contrasts of geotechnical properties in multiple soil layers. In this research, stability is modeled by using LOGISNET, an acronym for Multiple Logistic Regression, Geographic Information System, and Neural Network. The main purpose of LOGISNET is to provide government planners and decision makers a tool to assess landslide susceptibility. The system is fully operational for models handling an enhanced cartographic-hydrologic model (SINMAP) and multiple logistic regression. The enhanced implementation of SINMAP was tested at regional scale in the Highway 101 corridor in Del Norte County, California, and its susceptibility map was found to have improved factor of safety estimates based on comparison with landslide inventory maps. The enhanced SINMAP and multiple logistic regression subsystems have functions that allow the user to include vertical variation in geotechnical properties through summation of forces in specific soil layers acting on failure planes for a local or regional-scale mapping. The working group of LOGISNET foresees the development of an integrated tool system to handle and support the prognostic studies of slope instability, and communicate the results to the public through maps.

  14. Free-Suspension Residual Flexibility Testing of Space Station Pathfinder: Comparison to Fixed-Base Results

    Science.gov (United States)

    Tinker, Michael L.

    1998-01-01

    Application of the free-suspension residual flexibility modal test method to the International Space Station Pathfinder structure is described. The Pathfinder, a large structure of the general size and weight of Space Station module elements, was also tested in a large fixed-base fixture to simulate Shuttle Orbiter payload constraints. After correlation of the Pathfinder finite element model to residual flexibility test data, the model was coupled to a fixture model, and constrained modes and frequencies were compared to fixed-base test. modes. The residual flexibility model compared very favorably to results of the fixed-base test. This is the first known direct comparison of free-suspension residual flexibility and fixed-base test results for a large structure. The model correlation approach used by the author for residual flexibility data is presented. Frequency response functions (FRF) for the regions of the structure that interface with the environment (a test fixture or another structure) are shown to be the primary tools for model correlation that distinguish or characterize the residual flexibility approach. A number of critical issues related to use of the structure interface FRF for correlating the model are then identified and discussed, including (1) the requirement of prominent stiffness lines, (2) overcoming problems with measurement noise which makes the antiresonances or minima in the functions difficult to identify, and (3) the use of interface stiffness and lumped mass perturbations to bring the analytical responses into agreement with test data. It is shown that good comparison of analytical-to-experimental FRF is the key to obtaining good agreement of the residual flexibility values.

  15. Investigation of colistin sensitivity via three different methods in Acinetobacter baumannii isolates with multiple antibiotic resistance.

    Science.gov (United States)

    Sinirtaş, Melda; Akalin, Halis; Gedikoğlu, Suna

    2009-09-01

    In recent years there has been an increase in life-threatening infections caused by Acinetobacter baumannii with multiple antibiotic resistance, which has lead to the use of polymyxins, especially colistin, being reconsidered. The aim of this study was to investigate the colistin sensitivity of A. baumannii isolates with multiple antibiotic resistance via different methods, and to evaluate the disk diffusion method for colistin against multi-resistant Acinetobacter isolates, in comparison to the E-test and Phoenix system. The study was carried out on 100 strains of A. baumannii (colonization or infection) isolated from the microbiological samples of different patients followed in the clinics and intensive care units of Uludağ University Medical School between the years 2004 and 2005. Strains were identified and characterized for their antibiotic sensitivity by Phoenix system (Becton Dickinson, Sparks, MD, USA). In all studied A. baumannii strains, susceptibility to colistin was determined to be 100% with the disk diffusion, E-test, and broth microdilution methods. Results of the E-test and broth microdilution method, which are accepted as reference methods, were found to be 100% consistent with the results of the disk diffusion tests; no very major or major error was identified upon comparison of the tests. The sensitivity and the positive predictive value of the disk diffusion method were found to be 100%. Colistin resistance in A. baumannii was not detected in our region, and disk diffusion method results are in accordance with those of E-test and broth microdilution methods.

  16. Use of Pearson's Chi-Square for Testing Equality of Percentile Profiles across Multiple Populations.

    Science.gov (United States)

    Johnson, William D; Beyl, Robbie A; Burton, Jeffrey H; Johnson, Callie M; Romer, Jacob E; Zhang, Lei

    2015-08-01

    In large sample studies where distributions may be skewed and not readily transformed to symmetry, it may be of greater interest to compare different distributions in terms of percentiles rather than means. For example, it may be more informative to compare two or more populations with respect to their within population distributions by testing the hypothesis that their corresponding respective 10 th , 50 th , and 90 th percentiles are equal. As a generalization of the median test, the proposed test statistic is asymptotically distributed as Chi-square with degrees of freedom dependent upon the number of percentiles tested and constraints of the null hypothesis. Results from simulation studies are used to validate the nominal 0.05 significance level under the null hypothesis, and asymptotic power properties that are suitable for testing equality of percentile profiles against selected profile discrepancies for a variety of underlying distributions. A pragmatic example is provided to illustrate the comparison of the percentile profiles for four body mass index distributions.

  17. Comparison between Euro NCAP test results and real-world crash data.

    Science.gov (United States)

    Kullgren, Anders; Lie, Anders; Tingvall, Claes

    2010-12-01

    The objective of this study was 2-fold: first, to compare Euro NCAP safety ratings of cars with those published by the Folksam real-world injury ratings; and second, to compare injury risk measures between Euro NCAP 2 and 5 Star cars with real-world injury and disability outcomes using police and insurance injury data. Car models were grouped according to the Euro NCAP star rating scores. Folksam risk of injury ratings come from statistical analysis of real-world crashes using police and insurance databases. The paired comparison method using 2-car crashes was used to control for crash speed and the mass differences between cars of different weights were normalized. For all comparisons, 5-star rated Euro NCAP cars were found to have a lower risk of injury compared to 2-star rated cars (5-star cars were 10% ± 2.5% lower risk than 2-star cars). For fatal and serious injuries, the difference was 23 ± 8 percent, and for fatal injuries alone the difference was 68 ± 32 percent. By comparison, the Folksam 5-star rated cars had a relative risk of 0.020 ± 0.0024, whereas 2-star rated car risk was 0.028 ± 0.0016, corresponding to a 27 percent difference in risk between 5- and 2-star cars. Good correlation was found between Euro NCAP test results and real-world injury outcomes. The largest difference in injury risk between 2- and 5-star rated cars in Euro NCAP was found for risk of fatality, confirming that car manufacturers have focused their safety performance on serious crash outcomes. In addition, Euro NCAP crash tests were shown to be highly correlated with serious crash performance, confirming their relevance for evaluating real-world crash performance. Good concordance was found between Euro NCAP and Folksam real-world crash and injury ratings.

  18. Experiences in simulating and testing coordinated voltage control provided by multiple wind power plants

    Energy Technology Data Exchange (ETDEWEB)

    Arlaban, T.; Alonso, O.; Ortiz, D. [Acciona Windpower S.A. (Spain); Peiro, J.; Rivas, R. [Red Electrica de Espana SAU (Spain); Quinonez-Varela, G.; Lorenzo, P. [Acciona Energia S.A. (Spain)

    2011-07-01

    This document presents some field tests performed in a transmission system node in order to check the adequacy of voltage control performance by multiple wind power plants, with an overall capacity of 395 MW. It briefly explains the Spanish TSO motivation towards new voltage control requirements and the necessity of performing such tests in order to set the most convenient voltage control parameters and to verify the stable operation. It presents how different the voltage control capability between modern wind turbines (DFIG) and older ones (SCIG) specifically retrofitted for voltage control is. (orig.)

  19. Comparisons of Latinos, African Americans, and Caucasians with multiple sclerosis.

    Science.gov (United States)

    Buchanan, Robert J; Zuniga, Miguel A; Carrillo-Zuniga, Genny; Chakravorty, Bonnie J; Tyry, Tuula; Moreau, Rachel L; Huang, Chunfeng; Vollmer, Timothy

    2010-01-01

    Identify racial/ethnic differences among people with multiple sclerosis (MS) in demographics, MS disease characteristics, and health services received. We analyzed enrollment data from the Registry of the North American Research Committee on Multiple Sclerosis (NARCOMS) Project to compare 26,967 Caucasians, 715 Latinos, and 1,313 African Americans with MS. Racial/ethnic analyses of NARCOMS data focused on descriptive characteristics, using ANOVA and chi-square tests to identify significant differences in means and frequencies among Caucasians, Latinos, and African Americans. We identified significant racial/ethnic differences in demographics, MS disease characteristics, and treatments. Caucasians were older when first MS symptoms were experienced (30.1 years) and at MS diagnosis (37.4 years) than Latinos (28.6 years and 34.5 years) or African Americans (29.8 years and 35.8 years). Larger proportions of Latinos reported normal function for mobility and bladder/bowel function compared to Caucasians. Larger proportions of Latinos (44.2 percent) and African Americans (45.8 percent) reported at least mild depression compared to only 38.7 percent of Caucasians. Larger proportions of Latinos never received mental health care or care from rehabilitation specialists than Caucasians or African Americans. A larger proportion of African Americans had never been treated by a neurologist specializing in MS and a smaller proportion of African Americans received care at a MS clinic than Caucasians or Latinos. Our findings highlight the need for future analyses to determine if age, disease duration, MS symptoms, and disability levels provide additional insights into racial/ethic differences in the use of MS-related providers.

  20. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  1. Design of PH-based accelerated life testing plans under multiple-stress-type

    International Nuclear Information System (INIS)

    Elsayed, E.A.; Zhang Hao

    2007-01-01

    Accelerated life testing (ALT) is used to obtain failure time data quickly under high stress levels in order to predict product life performance under design stress conditions. Most of the previous work on designing ALT plans is focused on the application of a single stress. However, as components or products become more reliable due to technological advances, it becomes more difficult to obtain significant amount of failure data within reasonable amount of time using single stress only. Multiple-stress-type ALTs have been employed as a means of overcoming such difficulties. In this paper, we design optimum multiple-stress-type ALT plans based on the proportional hazards model. The optimum combinations of stresses and their levels are determined such that the variance of the reliability estimate of the product over a specified period of time is minimized. The use of the model is illustrated using numerical example, and sensitivity analysis shows that the resultant optimum ALT plan is robust to the deviation in model parameters

  2. Feedback-related brain activity predicts learning from feedback in multiple-choice testing.

    Science.gov (United States)

    Ernst, Benjamin; Steinhauser, Marco

    2012-06-01

    Different event-related potentials (ERPs) have been shown to correlate with learning from feedback in decision-making tasks and with learning in explicit memory tasks. In the present study, we investigated which ERPs predict learning from corrective feedback in a multiple-choice test, which combines elements from both paradigms. Participants worked through sets of multiple-choice items of a Swahili-German vocabulary task. Whereas the initial presentation of an item required the participants to guess the answer, corrective feedback could be used to learn the correct response. Initial analyses revealed that corrective feedback elicited components related to reinforcement learning (FRN), as well as to explicit memory processing (P300) and attention (early frontal positivity). However, only the P300 and early frontal positivity were positively correlated with successful learning from corrective feedback, whereas the FRN was even larger when learning failed. These results suggest that learning from corrective feedback crucially relies on explicit memory processing and attentional orienting to corrective feedback, rather than on reinforcement learning.

  3. Comparison between cerebral ischemia disease and multiple sclerosis by using MR diffusion tensor imaging

    International Nuclear Information System (INIS)

    Lou Xin; Cai Youquan; Ma Lin; Cai Jianming

    2007-01-01

    Objective: To assess the value of MR diffusion tensor imaging (DTI) in the differentiation between the patients with cerebral ischemia disease and multiple sclerosis. Methods: MR diffusion tensor imaging was performed in thirty-two patients with internal carotid artery stenosis ≥70% and eighteen patients with clinical diagnosed multiple sclerosis. Fractional anisotropy (FA) value of the germ, splenium, body of the corpus callosum, and the white matter of the frontal and occipital lobe were measured respectively, and independent-sample t-test statistical analysis was performed. Results: The FA value was decreased obviously in the anterior and posterior body and splenium of the corpus callosumin the MS patients compared with the ICA severe stenosis patients (0.67 ± 0.12 vs. 0.75 ± 0.05, t=3.443, P 0.05; 0.34 ± 0.08 vs. 0.34 ± 0.05, t=0.137, P> 0.05; 0.29 ± 0.06 vs. 0.40 ± 0.06, t=5.449, P>0.05). Conclusion: DTI can noninvasive detect the potential disorder of corpus callosum in vivo, thus providing useful information to differentiate the cerebral ischemia disease from multiple sclerosis. (authors)

  4. Comparison of ORSAT and SCARAB Reentry Analysis Tools for a Generic Satellite Test Case

    Science.gov (United States)

    Kelley, Robert L.; Hill, Nicole M.; Rochelle, W. C.; Johnson, Nicholas L.; Lips, T.

    2010-01-01

    Reentry analysis is essential to understanding the consequences of the full life cycle of a spacecraft. Since reentry is a key factor in spacecraft development, NASA and ESA have separately developed tools to assess the survivability of objects during reentry. Criteria such as debris casualty area and impact energy are particularly important to understanding the risks posed to people on Earth. Therefore, NASA and ESA have undertaken a series of comparison studies of their respective reentry codes for verification and improvements in accuracy. The NASA Object Reentry Survival Analysis Tool (ORSAT) and the ESA Spacecraft Atmospheric Reentry and Aerothermal Breakup (SCARAB) reentry analysis tools serve as standard codes for reentry survivability assessment of satellites. These programs predict whether an object will demise during reentry and calculate the debris casualty area of objects determined to survive, establishing the reentry risk posed to the Earth's population by surviving debris. A series of test cases have been studied for comparison and the most recent uses "Testsat," a conceptual satellite composed of generic parts, defined to use numerous simple shapes and various materials for a better comparison of the predictions of these two codes. This study is an improvement on the others in this series because of increased consistency in modeling techniques and variables. The overall comparison demonstrated that the two codes arrive at similar results. Either most objects modeled resulted in close agreement between the two codes, or if the difference was significant, the variance could be explained as a case of semantics in the model definitions. This paper presents the main results of ORSAT and SCARAB for the Testsat case and discusses the sources of any discovered differences. Discussion of the results of previous comparisons is made for a summary of differences between the codes and lessons learned from this series of tests.

  5. Translation and Adaptation of Tests: Lessons Learned and Recommendations for Countries Participating in timss, pisa and other International Comparisons

    Directory of Open Access Journals (Sweden)

    Guillermo Solano-Flores

    2006-11-01

    Full Text Available In this paper we present a conceptual model and methodology for the review of translated tests in the context of such international comparisons as the Trends in International Mathematics and Science Study (TIMSS and the Programme for International Student Assessment (PISA. We also present the results of an investigation into the quality of the Mexican translation of the TIMSS-1995 into the Spanish language. We identified translation errors in a significant percentage of the items, as well as relatively high correlations between the severity of translation errors and the items’ p-values. These findings indicate that our error-coding system is highly sensitive to test-translation error. The results underscore the need for improved translation and translation-review procedures in international comparisons. In our opinion, to implement the guidelines properly for test translation in international comparisons, each participating country needs to have internal procedures that would ensure a rigorous review of its own translations. The article concludes with four recommendations for countries participating in international comparisons. These recommendations relate to: (a the characteristics of the individuals in charge of translating instruments; (b the use of review, not simply at the end of the process, but during the process of test translation; (c the minimum time needed for various translation review iterations to take place; and (d the need for proper documentation of the entire process of test translation.

  6. Hadron multiplicity as the limit of jet multiplicity at high resolution

    International Nuclear Information System (INIS)

    Lupia, S.; Ochs, W.

    1998-01-01

    Recently exact numerical results from the evolution equation for parton multiplicities in QCD jets have been obtained. A comparison with various approximate results is presented. A good description is obtained not only of the jet multiplicities measured at LEP-1 but also of the hadron multiplicities for cm s energies above 1.6 GeV in e + e - annihilation. The solution suggests that a final state hadron can be represented by a jet in the limit of small (nonperturbative) k perpendicular to cut-off Q 0 . In this description using as adjustable parameters only the QCD scale Λ and the cut-off Q 0 , the coupling α s can be seen to rise towards large values above unity at low energies. (orig.)

  7. Assessment of Dermatoglyphics Multiple Intelligence Test (DMIT Reports: Implication to Career Guidance Program Enhancement of Academic Institutions

    Directory of Open Access Journals (Sweden)

    Dr. Maria Luisa A. Valdez

    2014-04-01

    Full Text Available This research aims to assess the reports generated from the Dermatoglyphics Multiple Intelligence Test (DMIT administered by selected DMIT resource companies and consultancy firms in India with the end view of identifying its implication to career guidance program enhancement of academic institutions. This paper employed the descriptive research method which involved the use of documentary analysis, questionnaires and interviews with purposively selected respondents supported by the researchers’ analysis and insights with reference to the content of the data. Findings of this research revealed that the dermatoglyphics, as a scientific discipline, began with the publication of Purkinje’s thesis (1823 and Galton’s classic book, Fingerprints (1892; DMIT is a remarkable offshoot of Howard Gardner’s Theory of Multiple Intelligences which has the following salient features: Overview of the Dermatoglyphics and the Dermatoglyphics Multiple Intelligence Test/Analysis; Personality Assessment; Profile based on Gardner’s Multiple Intelligences and Dunn’s Brain Lateralization Theories; Learning Styles; Competency and Compatibility Profiles; Working Style; Leadership Style; Management Style; Report Interpretation; and Customized Academic and Relationship Advises; the respondents of this study gave their perceptions with reference to the beneficial results of the DMIT; and the foregoing findings have some implications that may be used by academic institutions to enhance their career guidance program.

  8. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Halfon, Philippe; Bacq, Yannick; De Muret, Anne; Penaranda, Guillaume; Bourliere, Marc; Ouzan, Denis; Tran, Albert; Botta, Danielle; Renou, Christophe; Bréchot, Marie-Claude; Degott, Claude; Paradis, Valérie

    2007-03-01

    We evaluated the test performance profile (TPP) of blood tests of liver fibrosis. Three hundred and fifty-six patients with C chronic hepatitis were included in two centers. Metavir staging of liver specimens by two independent pathologists and the following tests were evaluated: Fibrotest (FT), APRI, FibroMeter (FM), and Hepascore (HS). Metavir stages were: F0: 4%, F1: 55%, F2: 26%, F3: 11%, and F4: 4%. The AUROCs were not significantly different, respectively, FT, FM, APRI, HS: >or=F2: 0.79, 0.78, 0.76, >or=0.76; F3: 0.81, 0.85, 0.81, 0.81; and F4: 0.86, 0.94, 0.92, 0.89. The TPP relies on the paired comparison of blood-test misclassification based on liver specimen, e.g. FT vs FM, respectively: F0+1: 18 vs 28% (p=0.0003), >or=F2: 43 vs 31% (p=0.004). There was no center effect. In those populations, the four blood tests had a similar performance for significant fibrosis (F>or=2), lying in the lower range of published results which is attributable to a low >or=F2 prevalence, and for >or=F3 and F4. However, FM and FT had performance profiles significantly different as a function of fibrosis stages or diagnostic target (fibrosis cut-off). This has to be considered during the interpretation process. Moreover, the performance should be reported with different diagnostic targets.

  9. Direct comparison of unloading compliance and potential drop techniques in J-integral testing

    International Nuclear Information System (INIS)

    McGowan, J.J.; Nanstad, R.K.

    1984-01-01

    Single-specimen J-integral testing is performed commonly with the unloading compliance technique. Use of modern instrumentation techniques and powerful desktop computers have made this technique a standard. However, this testing technique is slow and tedious, with the loading rate fixed at a slow quasi-static rate. For these reasons the dc potential drop technique was investigated for crack length measurement during a J-integral test. For direct comparison, both unloading compliance and potential drop were used simultaneously during a J-integral test. The results showed good agreement between the techniques. However, the potential drop technique showed an offset in crack length due to plastic blunting processes. Taking this offset into account, J/sub Ic/ values calculated by both techniques compared well

  10. New ISR and SPS collider multiplicity data and the Golokhvastov generalization of the KNO scaling

    International Nuclear Information System (INIS)

    Szwed, R.; Wrochna, G.

    1985-01-01

    The generalization of KNO scaling proposed by Golokhvastov (KNO-G scaling) is tested using pp multiplicity data, in particular results of the new high precision ISR measurements. Since the data obey KNO-G scaling over the full energy range √s=2.51-62.2 GeV with the scaling function psi(z), having only one free parameter, the superiority of the KNO-G over the standard approach is clearly demonstrated. The extrapolation within KNO-G scaling to the SPS Collider energy range and a comparison with the recent UA5 multiplicity results is presented. (orig.)

  11. Do Students Behave Rationally in Multiple Choice Tests? Evidence from a Field Experiment

    OpenAIRE

    María Paz Espinosa; Javier Gardeazabal

    2013-01-01

    A disadvantage of multiple choice tests is that students have incentives to guess. To discourage guessing, it is common to use scoring rules that either penalize wrong answers or reward omissions. In psychometrics, penalty and reward scoring rules are considered equivalent. However, experimental evidence indicates that students behave differently under penalty or reward scoring rules. These differences have been attributed to the different framing (penalty versus reward). In this paper, we mo...

  12. A general equation to obtain multiple cut-off scores on a test from multinomial logistic regression.

    Science.gov (United States)

    Bersabé, Rosa; Rivas, Teresa

    2010-05-01

    The authors derive a general equation to compute multiple cut-offs on a total test score in order to classify individuals into more than two ordinal categories. The equation is derived from the multinomial logistic regression (MLR) model, which is an extension of the binary logistic regression (BLR) model to accommodate polytomous outcome variables. From this analytical procedure, cut-off scores are established at the test score (the predictor variable) at which an individual is as likely to be in category j as in category j+1 of an ordinal outcome variable. The application of the complete procedure is illustrated by an example with data from an actual study on eating disorders. In this example, two cut-off scores on the Eating Attitudes Test (EAT-26) scores are obtained in order to classify individuals into three ordinal categories: asymptomatic, symptomatic and eating disorder. Diagnoses were made from the responses to a self-report (Q-EDD) that operationalises DSM-IV criteria for eating disorders. Alternatives to the MLR model to set multiple cut-off scores are discussed.

  13. Evidence-based point-of-care tests and device designs for disaster preparedness.

    Science.gov (United States)

    Brock, T Keith; Mecozzi, Daniel M; Sumner, Stephanie; Kost, Gerald J

    2010-01-01

    To define pathogen tests and device specifications needed for emerging point-of-care (POC) technologies used in disasters. Surveys included multiple-choice and ranking questions. Multiple-choice questions were analyzed with the chi2 test for goodness-of-fit and the binomial distribution test. Rankings were scored and compared using analysis of variance and Tukey's multiple comparison test. Disaster care experts on the editorial boards of the American Journal of Disaster Medicine and the Disaster Medicine and Public Health Preparedness, and the readers of the POC Journal. Vibrio cholera and Staphylococcus aureus were top-ranked pathogens for testing in disaster settings. Respondents felt that disaster response teams should be equipped with pandemic infectious disease tests for novel 2009 H1N1 and avian H5N1 influenza (disaster care, p disaster settings, respondents preferred self-contained test cassettes (disaster care, p disaster care, p disaster care scenarios, in which Vibrio cholera, methicillin-sensitive and methicillin-resistant Staphylococcus aureus, and Escherichia coli ranked the highest. POC testing should incorporate setting-specific design criteria such as safe disposable cassettes and direct blood sampling at the site of care.

  14. Results of aerosol code comparisons with releases from ACE MCCI tests

    International Nuclear Information System (INIS)

    Fink, J.K.; Corradini, M.; Hidaka, A.; Hontanon, E.; Mignanelli, M.A.; Schroedl, E.; Strizhov, V.

    1992-01-01

    Results of aerosol release calculations by six groups from six countries are compared with the releases from ACE MCCI Test L6. The codes used for these calculations included: SOLGASMIX-PV, SOLGASMIX Reactor 1986, CORCON.UW, VANESA 1.01, and CORCON mod2.04/VANESA 1.01. Calculations were performed with the standard VANESA 1.01 code and with modifications to the VANESA code such as the inclusion of various zirconium-silica chemical reactions. Comparisons of results from these calculations were made with Test L6 release fractions for U, Zr, Si, the fission-product elements Te, Ba, Sr, Ce, La, Mo and control materials Ag, In, and Ru. Reasonable agreement was obtained between calculations and Test L6 results for the volatile elements Ag, In and Te. Calculated releases of the low volatility fission products ranged from within an order of magnitude to five orders of magnitude of Test L6 values. Releases were over and underestimated by calculations. Poorest agreements were obtained for Mo and Si

  15. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  16. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  17. Multiple Site Damage in Flat Panel Testing

    National Research Council Canada - National Science Library

    Shrage, Daniel

    2000-01-01

    This report aimed to experimentally verify analytical models that predict the residual strength of representative aircraft structures, such as wide panels, that are subjected to Multiple Site Damage (MSD...

  18. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

    Energy Technology Data Exchange (ETDEWEB)

    Ezzell, Gary A.; Burmeister, Jay W.; Dogan, Nesrin [Department of Radiation Oncology, Mayo Clinic Scottsdale, 5777 East Mayo Boulevard, MCSB Concourse, Phoenix, Arizona 89054 (United States); and others

    2009-11-15

    AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

  19. Benefits and challenges of using the cohort multiple randomised controlled trial design for testing an intervention for depression.

    Science.gov (United States)

    Viksveen, Petter; Relton, Clare; Nicholl, Jon

    2017-07-06

    Trials which test the effectiveness of interventions compared with the status quo frequently encounter challenges. The cohort multiple randomised controlled trial (cmRCT) design is an innovative approach to the design and conduct of pragmatic trials which seeks to address some of these challenges. In this article, we report our experiences with the first completed randomised controlled trial (RCT) using the cmRCT design. This trial-the Depression in South Yorkshire (DEPSY) trial-involved comparison of treatment as usual (TAU) with TAU plus the offer of an intervention for people with self-reported long-term moderate to severe depression. In the trial, we used an existing large population-based cohort: the Yorkshire Health Study. We discuss our experiences with recruitment, attrition, crossover, data analysis, generalisability of results, and cost. The main challenges in using the cmRCT design were the high crossover to the control group and the lower questionnaire response rate among patients who refused the offer of treatment. However, the design did help facilitate efficient and complete recruitment of the trial population as well as analysable data that were generalisable to the population of interest. Attrition rates were also smaller than those reported in other depression trials. This first completed full trial using the cmRCT design testing an intervention for self-reported depression was associated with a number of important benefits. Further research is required to compare the acceptability and cost effectiveness of standard pragmatic RCT design with the cmRCT design. ISRCTN registry: ISRCTN02484593 . Registered on 7 Jan 2013.

  20. A Method for the Comparison of Item Selection Rules in Computerized Adaptive Testing

    Science.gov (United States)

    Barrada, Juan Ramon; Olea, Julio; Ponsoda, Vicente; Abad, Francisco Jose

    2010-01-01

    In a typical study comparing the relative efficiency of two item selection rules in computerized adaptive testing, the common result is that they simultaneously differ in accuracy and security, making it difficult to reach a conclusion on which is the more appropriate rule. This study proposes a strategy to conduct a global comparison of two or…

  1. Hadron multiplicity as the limit of jet multiplicity at high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Lupia, S.; Ochs, W. [Max-Planck-Institut fuer Physik, Muenchen (Germany). Werner-Heisenberg-Institut

    1998-05-01

    Recently exact numerical results from the evolution equation for parton multiplicities in QCD jets have been obtained. A comparison with various approximate results is presented. A good description is obtained not only of the jet multiplicities measured at LEP-1 but also of the hadron multiplicities for cm s energies above 1.6 GeV in e{sup +}e{sup -} annihilation. The solution suggests that a final state hadron can be represented by a jet in the limit of small (nonperturbative) k {sub perpendicular} {sub to} cut-off Q{sub 0}. In this description using as adjustable parameters only the QCD scale {Lambda} and the cut-off Q{sub 0}, the coupling {alpha}{sub s} can be seen to rise towards large values above unity at low energies. (orig.). 8 refs.

  2. Rapid Aminoglycoside NP Test for Rapid Detection of Multiple Aminoglycoside Resistance in Enterobacteriaceae.

    Science.gov (United States)

    Nordmann, Patrice; Jayol, Aurélie; Dobias, Jan; Poirel, Laurent

    2017-04-01

    The rapid aminoglycoside NP (Nordmann/Poirel) test was developed to rapidly identify multiple aminoglycoside (AG) resistance in Enterobacteriaceae It is based on the detection of the glucose metabolism related to enterobacterial growth in the presence of a defined concentration of amikacin plus gentamicin. Formation of acid metabolites was evidenced by a color change (orange to yellow) of the red phenol pH indicator. The rapid aminoglycoside NP test was evaluated by using bacterial colonies of 18 AG-resistant isolates producing 16S rRNA methylases, 20 AG-resistant isolates expressing AG-modifying enzymes (acetyl-, adenyl-, and phosphotransferases), and 10 isolates susceptible to AG. Its sensitivity and specificity were 100% and 97%, respectively, compared to the broth dilution method, which was taken as the gold standard for determining aminoglycoside resistance. The test is inexpensive, rapid (<2 h), and implementable worldwide. Copyright © 2017 American Society for Microbiology.

  3. MultiSETTER: web server for multiple RNA structure comparison.

    Science.gov (United States)

    Čech, Petr; Hoksza, David; Svozil, Daniel

    2015-08-12

    Understanding the architecture and function of RNA molecules requires methods for comparing and analyzing their tertiary and quaternary structures. While structural superposition of short RNAs is achievable in a reasonable time, large structures represent much bigger challenge. Therefore, we have developed a fast and accurate algorithm for RNA pairwise structure superposition called SETTER and implemented it in the SETTER web server. However, though biological relationships can be inferred by a pairwise structure alignment, key features preserved by evolution can be identified only from a multiple structure alignment. Thus, we extended the SETTER algorithm to the alignment of multiple RNA structures and developed the MultiSETTER algorithm. In this paper, we present the updated version of the SETTER web server that implements a user friendly interface to the MultiSETTER algorithm. The server accepts RNA structures either as the list of PDB IDs or as user-defined PDB files. After the superposition is computed, structures are visualized in 3D and several reports and statistics are generated. To the best of our knowledge, the MultiSETTER web server is the first publicly available tool for a multiple RNA structure alignment. The MultiSETTER server offers the visual inspection of an alignment in 3D space which may reveal structural and functional relationships not captured by other multiple alignment methods based either on a sequence or on secondary structure motifs.

  4. Robust inference from multiple test statistics via permutations: a better alternative to the single test statistic approach for randomized trials.

    Science.gov (United States)

    Ganju, Jitendra; Yu, Xinxin; Ma, Guoguang Julie

    2013-01-01

    Formal inference in randomized clinical trials is based on controlling the type I error rate associated with a single pre-specified statistic. The deficiency of using just one method of analysis is that it depends on assumptions that may not be met. For robust inference, we propose pre-specifying multiple test statistics and relying on the minimum p-value for testing the null hypothesis of no treatment effect. The null hypothesis associated with the various test statistics is that the treatment groups are indistinguishable. The critical value for hypothesis testing comes from permutation distributions. Rejection of the null hypothesis when the smallest p-value is less than the critical value controls the type I error rate at its designated value. Even if one of the candidate test statistics has low power, the adverse effect on the power of the minimum p-value statistic is not much. Its use is illustrated with examples. We conclude that it is better to rely on the minimum p-value rather than a single statistic particularly when that single statistic is the logrank test, because of the cost and complexity of many survival trials. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Comparison of multiple support excitation solution techniques for piping systems

    International Nuclear Information System (INIS)

    Sterkel, H.P.; Leimbach, K.R.

    1980-01-01

    Design and analysis of nuclear power plant piping systems exposed to a variety of dynamic loads often require multiple support excitation analysis by modal or direct time integration methods. Both methods have recently been implemented in the computer program KWUROHR for static and dynamic analysis of piping systems, following the previous implementation of the multiple support excitation response spectrum method (see papers K 6/15 and K 6/15a of the SMiRT-4 Conference). The results of multiple support excitation response spectrum analyses can be examined by carrying out the equivalent time history analyses which do not distort the time phase relationship between the excitations at different support points. A frequent point of discussion is multiple versus single support excitation. A single support excitation analysis is computationally straightforward and tends to be on the conservative side, as the numerical results show. A multiple support excitation analysis, however, does not incur much more additional computer cost than the expenditure for an initial static solution involving three times the number, L, of excitation levels, i.e. 3L static load cases. The results are more realistic than those from a single support excitation analysis. A number of typical nuclear plant piping systems have been analyzed using single and multiple support excitation algorithms for: (1) the response spectrum method, (2) the modal time history method via the Wilson, Newmark and Goldberg integration operators and (3) the direct time history method via the Wilson integration operator. Characteristic results are presented to compare the computational quality of all three methods. (orig.)

  6. Constructing a multiple choice test to measure elementary school teachers' Pedagogical Content Knowledge of technology education.

    NARCIS (Netherlands)

    Rohaan, E.J.; Taconis, R.; Jochems, W.M.G.

    2009-01-01

    This paper describes the construction and validation of a multiple choice test to measure elementary school teachers' Pedagogical Content Knowledge of technology education. Pedagogical Content Knowledge is generally accepted to be a crucial domain of teacher knowledge and is, therefore, an important

  7. Analysis of Multiple Genomic Sequence Alignments: A Web Resource, Online Tools, and Lessons Learned From Analysis of Mammalian SCL Loci

    Science.gov (United States)

    Chapman, Michael A.; Donaldson, Ian J.; Gilbert, James; Grafham, Darren; Rogers, Jane; Green, Anthony R.; Göttgens, Berthold

    2004-01-01

    Comparative analysis of genomic sequences is becoming a standard technique for studying gene regulation. However, only a limited number of tools are currently available for the analysis of multiple genomic sequences. An extensive data set for the testing and training of such tools is provided by the SCL gene locus. Here we have expanded the data set to eight vertebrate species by sequencing the dog SCL locus and by annotating the dog and rat SCL loci. To provide a resource for the bioinformatics community, all SCL sequences and functional annotations, comprising a collation of the extensive experimental evidence pertaining to SCL regulation, have been made available via a Web server. A Web interface to new tools specifically designed for the display and analysis of multiple sequence alignments was also implemented. The unique SCL data set and new sequence comparison tools allowed us to perform a rigorous examination of the true benefits of multiple sequence comparisons. We demonstrate that multiple sequence alignments are, overall, superior to pairwise alignments for identification of mammalian regulatory regions. In the search for individual transcription factor binding sites, multiple alignments markedly increase the signal-to-noise ratio compared to pairwise alignments. PMID:14718377

  8. An Efficient Stepwise Statistical Test to Identify Multiple Linked Human Genetic Variants Associated with Specific Phenotypic Traits.

    Directory of Open Access Journals (Sweden)

    Iksoo Huh

    Full Text Available Recent advances in genotyping methodologies have allowed genome-wide association studies (GWAS to accurately identify genetic variants that associate with common or pathological complex traits. Although most GWAS have focused on associations with single genetic variants, joint identification of multiple genetic variants, and how they interact, is essential for understanding the genetic architecture of complex phenotypic traits. Here, we propose an efficient stepwise method based on the Cochran-Mantel-Haenszel test (for stratified categorical data to identify causal joint multiple genetic variants in GWAS. This method combines the CMH statistic with a stepwise procedure to detect multiple genetic variants associated with specific categorical traits, using a series of associated I × J contingency tables and a null hypothesis of no phenotype association. Through a new stratification scheme based on the sum of minor allele count criteria, we make the method more feasible for GWAS data having sample sizes of several thousands. We also examine the properties of the proposed stepwise method via simulation studies, and show that the stepwise CMH test performs better than other existing methods (e.g., logistic regression and detection of associations by Markov blanket for identifying multiple genetic variants. Finally, we apply the proposed approach to two genomic sequencing datasets to detect linked genetic variants associated with bipolar disorder and obesity, respectively.

  9. Comparison of the sensitivity of typhi dot test with blood culture in typhoid

    Energy Technology Data Exchange (ETDEWEB)

    Rizvi, Q [Hamdard College of Medicine, Karachi (Pakistan). Dept. of Pharmacology

    2006-10-15

    To evaluate the sensitivity of Typhi Dot test in comparison to Blood Culture for the diagnosis of Typhoid Fever in our setup. Fifty patients who fulfilled the clinical criteria of having Typhoid Fever. The data of all the patients was documented, and they were submitted to the Typhi Dot and Blood Culture tests, apart from other routine investigations. Out of the total 50 patients, 47(94%) had their Blood Culture positive for Typhoid bacillus, while in 49 (98%) the Typhi Dot test was positive. Two patients which were found positive on Typhi dot test, gave negative results on Blood Culture. One patient with the signs and symptoms of Typhoid Fever was found neither positive on Typhi Dot test nor upon Blood Culture. There was no significant difference between the results of Blood Culture and Typhi Dot test in the diagnosis of Typhoid Fever. However, Typhi Dot has the advantages of being less expensive and quicker in giving results with excellent sensitivity. (author)

  10. Comparison of the sensitivity of typhi dot test with blood culture in typhoid

    International Nuclear Information System (INIS)

    Rizvi, Q.

    2006-01-01

    To evaluate the sensitivity of Typhi Dot test in comparison to Blood Culture for the diagnosis of Typhoid Fever in our setup. Fifty patients who fulfilled the clinical criteria of having Typhoid Fever. The data of all the patients was documented, and they were submitted to the Typhi Dot and Blood Culture tests, apart from other routine investigations. Out of the total 50 patients, 47(94%) had their Blood Culture positive for Typhoid bacillus, while in 49 (98%) the Typhi Dot test was positive. Two patients which were found positive on Typhi dot test, gave negative results on Blood Culture. One patient with the signs and symptoms of Typhoid Fever was found neither positive on Typhi Dot test nor upon Blood Culture. There was no significant difference between the results of Blood Culture and Typhi Dot test in the diagnosis of Typhoid Fever. However, Typhi Dot has the advantages of being less expensive and quicker in giving results with excellent sensitivity. (author)

  11. Methacholine challenge test: Comparison of tidal breathing and dosimeter methods in children.

    Science.gov (United States)

    Mazi, Ahlam; Lands, Larry C; Zielinski, David

    2018-02-01

    Methacholine Challenge Test (MCT) is used to confirm, assess the severity and/or rule out asthma. Two MCT methods are described as equivalent by the American Thoracic Society (ATS), the tidal breathing and the dosimeter methods. However, the majority of adult studies suggest that individuals with asthma do not react at the same PC 20 between the two methods. Additionally, the nebulizers used are no longer available and studies suggest current nebulizers are not equivalent to these. Our study investigates the difference in positive MCT tests between three methods in a pediatric population. A retrospective, chart review of all MCT performed with spirometry at the Montreal Children's Hospital from January 2006 to March 2016. A comparison of the percentage positive MCT tests with three methods, tidal breathing, APS dosimeter and dose adjusted DA-dosimeter, was performed at different cutoff points up to 8 mg/mL. A total of 747 subjects performed the tidal breathing method, 920 subjects the APS dosimeter method, and 200 subjects the DA-dosimeter method. At a PC 20 cutoff ≤4 mg/mL, the percentage positive MCT was significantly higher using the tidal breathing method (76.3%) compared to the APS dosimeter (45.1%) and DA-dosimeter (65%) methods (P < 0.0001). The choice of nebulizer and technique significantly impacts the rate of positivity when using MCT to diagnose and assess asthma. Lack of direct comparison of techniques within the same individuals and clinical assessment should be addressed in future studies to standardize MCT methodology in children. © 2017 Wiley Periodicals, Inc.

  12. Depression and pain: testing of serial multiple mediators

    Directory of Open Access Journals (Sweden)

    Wongpakaran T

    2016-07-01

    function were found to significantly mediate the relationship between depression and pain, while controlling for demographic variables. The total effect of depression on pain was significant. This model, with an additional three mediators, accounted for 15% of the explained variance in pain compared to 9% without mediators. For the alternative model, after controlling for the mediators, a nonsignificant total direct effect level of self-sacrificing was found, suggesting that the effect of self-sacrificing on pain was based only on an indirect effect and that perceived stress was found to be the strongest mediator.Conclusion: Serial mediation may help us to see how depression and pain are linked and what the fundamental mediators are in the chain. No significant, indirect effect of self-sacrificing on pain was observed, if perceived stress was not part of the depression and/or cognitive function mediational chain. The results shown here have implications for future research, both in terms of testing the model and in clinical application. Keywords: depressive disorder, mediator, serial mediation, multiple mediation

  13. Multiplication circuit for particle identification

    International Nuclear Information System (INIS)

    Gerlier, Jean

    1962-01-01

    After having commented some characteristics of the particles present in a cyclotron, and their interactions, this report addresses the development and the implementation of a method and a device for selecting and counting particles. The author presents the principle and existing techniques of selection. In comparison with an existing device, the proportional counter and the scintillator are replaced by junctions: a surface barrier type junction (a silicon N layer with a very thin oxygen layer playing the role of the P layer), and lithium-based junction (a silicon P type layer made intrinsic by migration of lithium). The author then describes the developed circuit and assembly (background of the choice of a multiplication circuit), and their operation. In the next part, he presents the performed tests and discuses the obtained results. He finally outlines the benefits of the herein presented circuit [fr

  14. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  15. LOFT/L9-3, Loss of Fluid Test, Anticipated Transients with Multiple Failures

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the third of the NRC L9 series of experiments on Anticipated Transients with Multiple Failures. Loss-of-feedwater effects were studied. The experiment was conducted on 7 April 1982

  16. Testing for direct genetic effects using a screening step in family-based association studies

    Directory of Open Access Journals (Sweden)

    Sharon M Lutz

    2013-11-01

    Full Text Available In genome wide association studies (GWAS, families based studies tend to have less power to detect genetic associations than population based studies, such as case-control studies. This can be an issue when testing if genes in a family based GWAS have a direct effect on the phenotype of interest or if the genes act indirectly through a secondary phenotype. When multiple SNPs are tested for a direct effect in the family based study, a screening step can be used to minimize the burden of multiple comparisons in the causal analysis. We propose a 2-stage screening step that can be incorporated into the family based association test (FBAT approach similar to the conditional mean model approach in the VanSteen-algorithm [1]. Simulations demonstrate that the type 1 error is preserved and this method is advantageous when multiple markers are tested. This method is illustrated by an application to the Framingham Heart Study.

  17. Gender and Ethnicity Differences in Multiple-Choice Testing. Effects of Self-Assessment and Risk-Taking Propensity

    Science.gov (United States)

    1993-05-01

    correctness of the response provides I some advantages. They are: i 1. Increased reliability of the test; 2. Examinees pay more attention to the multiple...their choice 3 of test date. Each sign up sheet was divided into four cells: Non-Hispanic males and females and Hispanic males and females. 3 I I I...certain prestige and financial rewards; or entering a conservatory of music for advanced training with a well-known pianist . Mr. H realizes that even

  18. Comparison of Ordinary Kriging and Multiple Indicator Kriging ...

    African Journals Online (AJOL)

    Michael O. Mensah

    Multiple Indicator Kriging (MIK) is one of the popular non-linear methods that can handle skewed distribution such as that for gold ... historical deposits: Nkran, Adubia, Abore, and a ... information from the mine on the geology of the deposit.

  19. A Methodological Inter-Comparison of Gridded Meteorological Products

    Science.gov (United States)

    Newman, A. J.; Clark, M. P.; Longman, R. J.; Giambelluca, T. W.; Arnold, J.

    2017-12-01

    Here we present a gridded meteorology inter-comparison using the state of Hawaíi as a testbed. This inter-comparison is motivated by two general goals: 1) the broad user community of gridded observation based meteorological fields should be aware of inter-product differences and the reasons they exist, which allows users to make informed choices on product selection to best meet their specific application(s); 2) we want to demonstrate the utility of inter-comparisons to meet the first goal, yet highlight that they are limited to mostly generic statements regarding attribution of differences that limits our understanding of these complex algorithms and obscures future research directions. Hawaíi is a useful testbed because it is a meteorologically complex region with well-known spatial features that are tied to specific physical processes (e.g. the trade wind inversion). From a practical standpoint, there are now several monthly climatological and daily precipitation and temperature datasets available that are being used for impact modeling. General conclusions that have emerged are: 1) differences in input station data significantly influence product differences; 2) prediction of precipitation occurrence is crucial across multiple metrics; 3) derived temperature statistics (e.g. diurnal temperature range) may have large spatial differences across products; and 4) attribution of differences to methodological choices is difficult and may limit the outcomes of these inter-comparisons, particularly from a development viewpoint. Thus, we want to continue to move the community towards frameworks that allow for multiple options throughout the product generation chain and allow for more systematic testing.

  20. Reliability and validity of the Attributional Style Questionnaire- Survey in people with multiple sclerosis

    Science.gov (United States)

    Kneebone, Ian I.; Dewar, Sophie J.

    2016-01-01

    Background: The current study aimed to examine the psychometric properties of an attributional style measure that can be administered remotely, to people who have multiple sclerosis (MS). Methods: A total of 495 participants with MS were recruited. Participants completed the Attributional Style Questionnaire-Survey (ASQ-S) and two comparison measures of cognitive variables via postal survey on three occasions, each 12 months apart. Internal reliability, test-retest reliability and congruent validity were considered. Results: The internal reliability of the ASQ-S was good (α > 0.7). The test-retest correlations were significant, but failed to reach the 0.7 set. The congruent validity of the ASQ-S was established relative to the comparisons. Conclusions: The psychometric properties of the ASQ-S indicate that it shows promise as a tool for researchers investigating depression in people with MS and is likely sound to use clinically in this population. PMID:28450893

  1. International Comparisons of Income Inequality: Tests for Lorenz Dominance across Nine Countries

    OpenAIRE

    Bishop, John; Smith, W. James; Formby, John

    1989-01-01

    This paper examines income inequality across nine countries using the Luxembourg Income Study data set. New statistical tests and comparability of data provide an exceptionally clear picture of relative income inequality. Only 4 comparisons out of a possible 108 cannot be ranked. In most cases, differences in the definition of the recipient unit make little difference in the rankings. Irrespective of recipient units, Sweden, Norway, and Germany come out at the top of the ordinal Lorenz rankin...

  2. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  3. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-01-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (μg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r = 0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r = 0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA

  4. Neutron recognition in the LAND detector for large neutron multiplicity

    Energy Technology Data Exchange (ETDEWEB)

    Pawlowski, P., E-mail: piotr.pawlowski@ifj.edu.pl [Institute of Nuclear Physics, PAN, Radzikowskiego 152, 31-342 Krakow (Poland); Brzychczyk, J. [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Krakow (Poland); Leifels, Y.; Trautmann, W. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Adrich, P. [National Centre for Nuclear Research, PL-00681 Warsaw (Poland); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Aumann, T. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Bacri, C.O. [Institut de Physique Nucleaire, IN2P3-CNRS et Universite, F-91406 Orsay (France); Barczyk, T. [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Krakow (Poland); Bassini, R. [Istituto di Scienze Fisiche, Universita degli Studi and INFN, I-20133 Milano (Italy); Bianchin, S. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Boiano, C. [Istituto di Scienze Fisiche, Universita degli Studi and INFN, I-20133 Milano (Italy); Boretzky, K. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Boudard, A. [IRFU/SPhN, CEA/Saclay, F-91191 Gif-sur-Yvette (France); Chbihi, A. [GANIL, CEA et IN2P3-CNRS, F-14076 Caen (France); Cibor, J.; Czech, B. [Institute of Nuclear Physics, PAN, Radzikowskiego 152, 31-342 Krakow (Poland); De Napoli, M. [Dipartimento di Fisica e Astronomia-Universita and INFN-CT and LNS, I-95123 Catania (Italy); and others

    2012-12-01

    The performance of the LAND neutron detector is studied. Using an event-mixing technique based on one-neutron data obtained in the S107 experiment at the GSI laboratory, we test the efficiency of various analytic tools used to determine the multiplicity and kinematic properties of detected neutrons. A new algorithm developed recently for recognizing neutron showers from spectator decays in the ALADIN experiment S254 is described in detail. Its performance is assessed in comparison with other methods. The properties of the observed neutron events are used to estimate the detection efficiency of LAND in this experiment.

  5. Multiple high-intensity focused ultrasound probes for kidney-tissue ablation.

    Science.gov (United States)

    Häcker, Axel; Chauhan, Sunita; Peters, Kristina; Hildenbrand, Ralf; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan

    2005-10-01

    To investigate kidney-tissue ablation by high-intensity focused ultrasound (HIFU) using multiple and single probes. Ultrasound beams (1.75 MHz) produced by a piezoceramic element (focal distance 80 mm) were focused at the center of renal parenchyma. One of the three probes (mounted on a jig) could also be used for comparison with a single probe at comparable power ratings. Lesion dimensions were examined in perfused and unperfused ex vivo porcine kidneys at different power levels (40, 60, and 80 W) and treatment times (4, 6, and 8 seconds). At identical power levels, the lesions induced by multiple probes were larger than those induced by a single probe. Lesion size increased with increasing pulse duration and generator power. The sizes and shapes of the lesions were predictably repeatable in all samples. Lesions in perfused kidneys were smaller than those in unperfused kidneys. Ex vivo, kidney-tissue ablation by means of multiple HIFU probes offers significant advantages over single HIFU probes in respect of lesion size and formation. These advantages need to be confirmed by tests in vivo at higher energy levels.

  6. Analysis and prediction of Multiple-Site Damage (MSD) fatigue crack growth

    Science.gov (United States)

    Dawicke, D. S.; Newman, J. C., Jr.

    1992-08-01

    A technique was developed to calculate the stress intensity factor for multiple interacting cracks. The analysis was verified through comparison with accepted methods of calculating stress intensity factors. The technique was incorporated into a fatigue crack growth prediction model and used to predict the fatigue crack growth life for multiple-site damage (MSD). The analysis was verified through comparison with experiments conducted on uniaxially loaded flat panels with multiple cracks. Configuration with nearly equal and unequal crack distribution were examined. The fatigue crack growth predictions agreed within 20 percent of the experimental lives for all crack configurations considered.

  7. Analysis and prediction of Multiple-Site Damage (MSD) fatigue crack growth

    Science.gov (United States)

    Dawicke, D. S.; Newman, J. C., Jr.

    1992-01-01

    A technique was developed to calculate the stress intensity factor for multiple interacting cracks. The analysis was verified through comparison with accepted methods of calculating stress intensity factors. The technique was incorporated into a fatigue crack growth prediction model and used to predict the fatigue crack growth life for multiple-site damage (MSD). The analysis was verified through comparison with experiments conducted on uniaxially loaded flat panels with multiple cracks. Configuration with nearly equal and unequal crack distribution were examined. The fatigue crack growth predictions agreed within 20 percent of the experimental lives for all crack configurations considered.

  8. Design of clinical trials involving multiple hypothesis tests with a common control.

    Science.gov (United States)

    Schou, I Manjula; Marschner, Ian C

    2017-07-01

    Randomized clinical trials comparing several treatments to a common control are often reported in the medical literature. For example, multiple experimental treatments may be compared with placebo, or in combination therapy trials, a combination therapy may be compared with each of its constituent monotherapies. Such trials are typically designed using a balanced approach in which equal numbers of individuals are randomized to each arm, however, this can result in an inefficient use of resources. We provide a unified framework and new theoretical results for optimal design of such single-control multiple-comparator studies. We consider variance optimal designs based on D-, A-, and E-optimality criteria, using a general model that allows for heteroscedasticity and a range of effect measures that include both continuous and binary outcomes. We demonstrate the sensitivity of these designs to the type of optimality criterion by showing that the optimal allocation ratios are systematically ordered according to the optimality criterion. Given this sensitivity to the optimality criterion, we argue that power optimality is a more suitable approach when designing clinical trials where testing is the objective. Weighted variance optimal designs are also discussed, which, like power optimal designs, allow the treatment difference to play a major role in determining allocation ratios. We illustrate our methods using two real clinical trial examples taken from the medical literature. Some recommendations on the use of optimal designs in single-control multiple-comparator trials are also provided. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Measuring University students' understanding of the greenhouse effect - a comparison of multiple-choice, short answer and concept sketch assessment tools with respect to students' mental models

    Science.gov (United States)

    Gold, A. U.; Harris, S. E.

    2013-12-01

    The greenhouse effect comes up in most discussions about climate and is a key concept related to climate change. Existing studies have shown that students and adults alike lack a detailed understanding of this important concept or might hold misconceptions. We studied the effectiveness of different interventions on University-level students' understanding of the greenhouse effect. Introductory level science students were tested for their pre-knowledge of the greenhouse effect using validated multiple-choice questions, short answers and concept sketches. All students participated in a common lesson about the greenhouse effect and were then randomly assigned to one of two lab groups. One group explored an existing simulation about the greenhouse effect (PhET-lesson) and the other group worked with absorption spectra of different greenhouse gases (Data-lesson) to deepen the understanding of the greenhouse effect. All students completed the same assessment including multiple choice, short answers and concept sketches after participation in their lab lesson. 164 students completed all the assessments, 76 completed the PhET lesson and 77 completed the data lesson. 11 students missed the contrasting lesson. In this presentation we show the comparison between the multiple-choice questions, short answer questions and the concept sketches of students. We explore how well each of these assessment types represents student's knowledge. We also identify items that are indicators of the level of understanding of the greenhouse effect as measured in correspondence of student answers to an expert mental model and expert responses. Preliminary data analysis shows that student who produce concept sketch drawings that come close to expert drawings also choose correct multiple-choice answers. However, correct multiple-choice answers are not necessarily an indicator that a student produces an expert-like correlating concept sketch items. Multiple-choice questions that require detailed

  10. A FIRST COMPARISON OF KEPLER PLANET CANDIDATES IN SINGLE AND MULTIPLE SYSTEMS

    International Nuclear Information System (INIS)

    Latham, David W.; Quinn, Samuel N.; Carter, Joshua A.; Holman, Matthew J.; Rowe, Jason F.; Borucki, William J.; Bryson, Stephen T.; Howell, Steve B.; Batalha, Natalie M.; Brown, Timothy M.; Buchhave, Lars A.; Caldwell, Douglas A.; Christiansen, Jessie L.; Ciardi, David R.; Cochran, William D.; Dunham, Edward W.; Fabrycky, Daniel C.; Ford, Eric B.; Gautier, Thomas N. III; Gilliland, Ronald L.

    2011-01-01

    In this Letter, we present an overview of the rich population of systems with multiple candidate transiting planets found in the first four months of Kepler data. The census of multiples includes 115 targets that show two candidate planets, 45 with three, eight with four, and one each with five and six, for a total of 170 systems with 408 candidates. When compared to the 827 systems with only one candidate, the multiples account for 17% of the total number of systems, and one-third of all the planet candidates. We compare the characteristics of candidates found in multiples with those found in singles. False positives due to eclipsing binaries are much less common for the multiples, as expected. Singles and multiples are both dominated by planets smaller than Neptune; 69 +2 -3 % for singles and 86 +2 -5 % for multiples. This result, that systems with multiple transiting planets are less likely to include a transiting giant planet, suggests that close-in giant planets tend to disrupt the orbital inclinations of small planets in flat systems, or maybe even prevent the formation of such systems in the first place.

  11. Tests for homogeneity for multiple 2 x 2 contingency tables

    International Nuclear Information System (INIS)

    Carr, D.B.

    1986-01-01

    Frequently data are described by 2 x 2 contingency tables. For example, each 2 x 2 table arises from two dichotomous classifications such as control/treated and respond/did not respond. Multiple 2 x 2 tables result from stratifying the observational units on the basis of other characteristics. For example, stratifying by sex produces separate 2 x 2 tables for males and females. From each table a measure of difference between the response rates for the control and the treated groups is computed. The researcher usually wants to know if the response-rate difference is zero for each table. If the tables are homogeneous, the researcher can generalize from a statement concerning an average to a statement concerning each table. If tables are not homogeneous, homogeneous subsets of the tables should be described separately. This paper presents tests for homogeneity and illustrates their use. 11 refs., 6 tabs

  12. Multiplicity: discussion points from the Statisticians in the Pharmaceutical Industry multiplicity expert group.

    Science.gov (United States)

    Phillips, Alan; Fletcher, Chrissie; Atkinson, Gary; Channon, Eddie; Douiri, Abdel; Jaki, Thomas; Maca, Jeff; Morgan, David; Roger, James Henry; Terrill, Paul

    2013-01-01

    In May 2012, the Committee of Health and Medicinal Products issued a concept paper on the need to review the points to consider document on multiplicity issues in clinical trials. In preparation for the release of the updated guidance document, Statisticians in the Pharmaceutical Industry held a one-day expert group meeting in January 2013. Topics debated included multiplicity and the drug development process, the usefulness and limitations of newly developed strategies to deal with multiplicity, multiplicity issues arising from interim decisions and multiregional development, and the need for simultaneous confidence intervals (CIs) corresponding to multiple test procedures. A clear message from the meeting was that multiplicity adjustments need to be considered when the intention is to make a formal statement about efficacy or safety based on hypothesis tests. Statisticians have a key role when designing studies to assess what adjustment really means in the context of the research being conducted. More thought during the planning phase needs to be given to multiplicity adjustments for secondary endpoints given these are increasing in importance in differentiating products in the market place. No consensus was reached on the role of simultaneous CIs in the context of superiority trials. It was argued that unadjusted intervals should be employed as the primary purpose of the intervals is estimation, while the purpose of hypothesis testing is to formally establish an effect. The opposing view was that CIs should correspond to the test decision whenever possible. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Validation Test of Geant4 Simulation of Electron Backscattering

    CERN Document Server

    Kim, Sung Hun; Basaglia, Tullio; Han, Min Cheol; Hoff, Gabriela; Kim, Chan Hyeong; Saracco, Paolo

    2015-01-01

    Backscattering is a sensitive probe of the accuracy of electron scattering algorithms implemented in Monte Carlo codes. The capability of the Geant4 toolkit to describe realistically the fraction of electrons backscattered from a target volume is extensively and quantitatively evaluated in comparison with experimental data retrieved from the literature. The validation test covers the energy range between approximately 100 eV and 20 MeV, and concerns a wide set of target elements. Multiple and single electron scattering models implemented in Geant4, as well as preassembled selections of physics models distributed within Geant4, are analyzed with statistical methods. The evaluations concern Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the range of Geant4 versions, not always in the direction of better compatibility with experiment. Goodness-of-fit tests complemented by categorical analysis tests identify a configuration based on Geant4 Urban multiple scattering model in Geant4 vers...

  14. Does vagotomy protect against multiple sclerosis?

    Science.gov (United States)

    Sundbøll, Jens; Horváth-Puhó, Erzsébet; Adelborg, Kasper; Svensson, Elisabeth

    2017-07-01

    To examine the association between vagotomy and multiple sclerosis. We conducted a matched cohort study of all patients who underwent truncal or super-selective vagotomy and a comparison cohort, by linking Danish population-based medical registries (1977-1995). Hazard ratios (HRs) for multiple sclerosis, adjusting for potential confounders were computed by means of Cox regression analysis. Median age of multiple sclerosis onset corresponded to late onset multiple sclerosis. No association with multiple sclerosis was observed for truncal vagotomy (0-37 year adjusted HR=0.91, 95% confidence interval [CI]: 0.48-1.74) or super-selective vagotomy (0-37 year adjusted HR=1.28, 95% CI: 0.79-2.09) compared with the general population. We found no association between vagotomy and later risk of late onset multiple sclerosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  16. Recall strategies for the verbal fluency test in patients with multiple sclerosis.

    Science.gov (United States)

    Velázquez-Cardoso, J; Marosi-Holczberger, E; Rodríguez-Agudelo, Y; Yañez-Tellez, G; Chávez-Oliveros, M

    2014-04-01

    Multiple sclerosis (MS) is a neurodegenerative disease characterised by inflammation and demyelination. It generates irreversible myelin changes, which in turn give rise to physical and cognitive disorders. The verbal fluency test (VF) has been shown to be a sensitive tool for detecting cognitive impairment in these patients. To compare quantitative and qualitative aspects of performance on semantic and phonological fluency tests between MS patients and healthy controls by analysing total words produced and strategies used (clusters and switching). We evaluated 46 patients with MS and 33 healthy controls using the VF test. The semantic VF task revealed no significant differences between groups; for the phonological task, patients demonstrated reduced word production (F [77]=2.286 P<.001) and poorer use of grouping strategies, resulting in more frequent switching (F [77]=3.808 P<.005). These results support using qualitative analysis for recall strategies, since the technique provides data about which components of the task are affected by brain damage. Clusters depend on the integrity of semantic memory, while switching has to do with developing effective search strategies, cognitive flexibility, and the ability to modify responses. Frontal lobe damage has been reported in MS, and this is consistent with results from the phonological VF test. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  17. Comparison of Domestic Safety Review and European Union(EU) Stress Test After Nuclear Accident in Fukushima Daiichi NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hwa Sung; Kim, Jin Weon [Chosun University, Gwangju (Korea, Republic of)

    2016-05-15

    The European Union(EU) nuclear regulators group established stress test criteria and procedures, and utilities performed a self-review in accordance with those criteria and procedures. For Wolsung nuclear unit-1,the stress test was additionally conducted for deciding the continued operation of NPP, even though the safety review had been conducted after Fukushima NPP accident. Thus, this study is to compares the process, criteria, and results of the safety review performed in domestic NPPs and EU stress test performed in Cernavoda NPP. From the comparisons, the effectiveness and necessity of the stress test to decide the continued operation of NPPs is discussed. and the improvement items for safety enhancement are derived. The comparison showed that the process and review criteria of EU stress test was more systematic and specific than those used in domestic NPPs. But it was indicated that the improvement items resulted from the safety review performed in domestic NPPs are more comprehensive and powerful than EU stress tests (Cernavoda NPP) results. EU stress test for Cernavoda NPP evaluated in 3 fieldsand derived 13 design change items. The 50 improvement items derived from domestic safety review were including the contents of these 13 items.

  18. The Development and Validation of Test Instruments to Measure Observation and Comparison in Junior High School Science.

    Science.gov (United States)

    Hungerford, Harold Ralph

    This study attempted to design tests for the purpose of measuring the acquisition of the science skills of observation and comparison, to determine if these skills, as measured by these tests, could be differentially improved using differing amounts of training, and to determine the effects of race and cultural status on performance with the…

  19. Comparison of the evolution of tumor cells after unique and multiple (accelerated) daily irradiation in mammary carcinoma of C3H mice

    International Nuclear Information System (INIS)

    Pfersdorff, J.; Sack, H.

    1986-01-01

    The comparison of two fractionation schemes, i.e. the usual irradiation once a day with 2 Gy (SDF) and the fractionation with 3 times 1.6 Gy per day (MDF) at intervals of at least four hours shows the stronger action of higher fractionation on the destruction of tumor cells and the inhibition of their proliferation kinetics. So the number of pycnotic cells is considerably increased in case of multiple daily irradiation, and the mitosis rate as well as the labelling index show a more significant decrease. In case of one irradiation per day, the number of pycnotic cells increases during radiotherapy, too, but the mitosis rate and the labelling index only decrease until the fifth or sixth treatment day, remaining then unchanged or increasing slightly. This suggests a recurring multiplication of tumor cells already during radiotherapy. The higher efficacy of multiple daily fractionation in rapidly proliferating tumors is proved by the measurements of changing tumor volumes in the living animal during irradiation as well as by the observation of the survival time after irradiation. (orig.) [de

  20. A SAS macro for testing differences among three or more independent groups using Kruskal-Wallis and Nemenyi tests.

    Science.gov (United States)

    Liu, Yuewei; Chen, Weihong

    2012-02-01

    As a nonparametric method, the Kruskal-Wallis test is widely used to compare three or more independent groups when an ordinal or interval level of data is available, especially when the assumptions of analysis of variance (ANOVA) are not met. If the Kruskal-Wallis statistic is statistically significant, Nemenyi test is an alternative method for further pairwise multiple comparisons to locate the source of significance. Unfortunately, most popular statistical packages do not integrate the Nemenyi test, which is not easy to be calculated by hand. We described the theory and applications of the Kruskal-Wallis and Nemenyi tests, and presented a flexible SAS macro to implement the two tests. The SAS macro was demonstrated by two examples from our cohort study in occupational epidemiology. It provides a useful tool for SAS users to test the differences among three or more independent groups using a nonparametric method.

  1. Numerical models: Detailing and simulation techniques aimed at comparison with experimental data, support to test result interpretation

    International Nuclear Information System (INIS)

    Lin Chiwen

    2001-01-01

    This part of the presentation discusses the modelling details required and the simulation techniques available for analyses, facilitating the comparison with the experimental data and providing support for interpretation of the test results. It is organised to cover the following topics: analysis inputs; basic modelling requirements for reactor coolant system; method applicable for reactor cooling system; consideration of damping values and integration time steps; typical analytic models used for analysis of reactor pressure vessel and internals; hydrodynamic mass and fluid damping for the internal analysis; impact elements for fuel analysis; and PEI theorem and its applications. The intention of these topics is to identify the key parameters associated with models of analysis and analytical methods. This should provide proper basis for useful comparison with the test results

  2. Male gender and smoking are related to single, but not to multiple, human aortic aneurysms.

    Science.gov (United States)

    Gutierrez, Paulo S; Leite, Thiago N P; Mangione, Fernanda M

    2015-01-01

    There is scanty information concerning multiple aortic aneurysms. Thus, we verified if clinical or pathological characteristics are different in patients with multiple (two or more) aortic aneurysms in comparison with those with only one. We selected at the necropsy files of the Heart Institute, São Paulo University School of Medicine, the last 100 cases with aortic aneurysms, comparing between the two groups: sex, age, presence of systemic arterial hypertension, diabetes, dyslipedemia, history of smoking habit, cause of the aneurysm, cause of death, and if the diagnosis was reached during life. Age was analysed by Mann-Whitney test, and the other variables by chi-square or Fisher's exact test. Multiple aneurysms corresponded to 14% of cases. The proportion of women among patients with multiple aneurysms was higher than among those with single aneurysm (64.3% versus 20.9%, P<.01), even if only cases with atherosclerosis were taken into consideration (women among multiple-6/10, 60.0%; among single-14/70, 20.0%; P=.01). Smoking was less reported in cases with multiple (4/14, 28.6%) than with single aneurysm (53/86, 61.6%; P=.04); considering cases with atherosclerosis, such difference decreases (40.0% of multiple versus 68.6% of single, P=.09). although atherosclerosis is present in most cases of both single and multiple aortic aneurysms, male gender and smoking, considered highly influential in such lesions, are less frequent in patients with multiple than in patients with single aneurysms. Thus mechanisms underlying multiple aortic aneurysms are probably different from those related to single, more common aneurysms. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Comparison of multiple-criteria decision-making methods - results of simulation study

    Directory of Open Access Journals (Sweden)

    Michał Adamczak

    2016-12-01

    Full Text Available Background: Today, both researchers and practitioners have many methods for supporting the decision-making process. Due to the conditions in which supply chains function, the most interesting are multi-criteria methods. The use of sophisticated methods for supporting decisions requires the parameterization and execution of calculations that are often complex. So is it efficient to use sophisticated methods? Methods: The authors of the publication compared two popular multi-criteria decision-making methods: the  Weighted Sum Model (WSM and the Analytic Hierarchy Process (AHP. A simulation study reflects these two decision-making methods. Input data for this study was a set of criteria weights and the value of each in terms of each criterion. Results: The iGrafx Process for Six Sigma simulation software recreated how both multiple-criteria decision-making methods (WSM and AHP function. The result of the simulation was a numerical value defining the preference of each of the alternatives according to the WSM and AHP methods. The alternative producing a result of higher numerical value  was considered preferred, according to the selected method. In the analysis of the results, the relationship between the values of the parameters and the difference in the results presented by both methods was investigated. Statistical methods, including hypothesis testing, were used for this purpose. Conclusions: The simulation study findings prove that the results obtained with the use of two multiple-criteria decision-making methods are very similar. Differences occurred more frequently in lower-value parameters from the "value of each alternative" group and higher-value parameters from the "weight of criteria" group.

  4. Making a difference? A comparison between multi-sensory and regular storytelling for persons with profound intellectual and multiple disabilities.

    Science.gov (United States)

    Ten Brug, A; Van der Putten, A A J; Penne, A; Maes, B; Vlaskamp, C

    2016-11-01

    Multi-sensory storytelling (MSST) was developed to include persons with profound intellectual and multiple disabilities in storytelling culture. In order to increase the listeners' attention, MSST stories are individualised and use multiple sensory stimuli to support the verbal text. In order to determine the value of MSST, this study compared listeners' attention under two conditions: (1) being read MSST books and (2) being read regular stories. A non-randomised control study was executed in which the intervention group read MSST books (n = 45) and a comparison group (n = 31) read regular books. Books were read 10 times during a 5-week period. The 1st, 5th and 10th storytelling sessions were recorded on video in both groups, and the percentage of attention directed to the book and/or stimuli and to the storyteller was scored by a trained and independent rater. Two repeated measure analyses (with the storytelling condition as a between-subject factor and the three measurements as factor) were performed to determine the difference between the groups in terms of attention directed to the book/stimuli (first analysis) and storyteller (second analysis). A further analysis established whether the level of attention changed between the reading sessions and whether there was an interaction effect between the repetition of the book and the storytelling condition. The attention directed to the book and/or the stimuli was significantly higher in the MSST group than in the comparison group. No significant difference between the two groups was found in the attention directed to the storyteller. For MSST stories, most attention was observed during the fifth reading session, while for regular stories, the fifth session gained least attentiveness from the listener. The persons with profound intellectual and multiple disabilities paid more attention to the book and/or stimuli in the MSST condition compared with the regular story telling group. Being more attentive towards

  5. The test beamline of the European Spallation Source - Instrumentation development and wavelength frame multiplication

    DEFF Research Database (Denmark)

    Woracek, R.; Hofmann, T.; Bulat, M.

    2016-01-01

    which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor...... wavelength band between 1.6 A and 10 A by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components....... This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects....

  6. What Is Social Comparison and How Should We Study It?

    Science.gov (United States)

    Wood, Joanne V.

    1996-01-01

    Examines frequently used measures and procedures in social comparison research. The question of whether a method truly captures social comparison requires a clear understanding of what social comparison is; hence a definition of social comparison is proposed, multiple ancillary processes in social comparison are identified, and definitional…

  7. Performance of Men and Women on Multiple-Choice and Constructed-Response Tests for Beginning Teachers. Research Report. ETS RR-04-48

    Science.gov (United States)

    Livingston, Samuel A.; Rupp, Stacie L.

    2004-01-01

    Some previous research results imply that women tend to perform better, relative to men, on constructed-response (CR) tests than on multiple-choice (MC) tests in the same subjects. An analysis of data from several tests used in the licensing of beginning teachers supported this hypothesis, to varying degrees, in most of the tests investigated. The…

  8. Comparison of stress in single and multiple layer depositions of plasma-deposited amorphous silicon dioxide

    International Nuclear Information System (INIS)

    Au, V; Charles, C; Boswell, R W

    2006-01-01

    The stress in a single-layer continuous deposition of amorphous silicon dioxide (SiO 2 ) film is compared with the stress within multiple-layer intermittent or 'stop-start' depositions. The films were deposited by helicon activated reactive evaporation (plasma assisted deposition with electron beam evaporation source) to a 1 μm total film thickness. The relationships for stress as a function of film thickness for single, two, four and eight layer depositions have been obtained by employing the substrate curvature technique on a post-deposition etch-back of the SiO 2 film. At film thicknesses of less than 300 nm, the stress-thickness relationships clearly show an increase in stress in the multiple-layer samples compared with the relationship for the single-layer film. By comparison, there is little variation in the film stress between the samples when it is measured at 1 μm film thickness. Localized variations in stress were not observed in the regions where the 'stop-start' depositions occurred. The experimental results are interpreted as a possible indication of the presence of unstable, strained Si-O-Si bonds in the amorphous SiO 2 film. It is proposed that the subsequent introduction of a 'stop-start' deposition process places additional strain on these bonds to affect the film structure. The experimental stress-thickness relationships were reproduced independently by assuming a linear relationship between the measured bow and film thickness. The constants of the linear model are interpreted as an indication of the density of the amorphous film structure

  9. Force Concept Inventory-based multiple-choice test for investigating students’ representational consistency

    Directory of Open Access Journals (Sweden)

    Pasi Nieminen

    2010-08-01

    Full Text Available This study investigates students’ ability to interpret multiple representations consistently (i.e., representational consistency in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI, which makes use of nine items from the 1995 version of the Force Concept Inventory (FCI. These original FCI items were redesigned using various representations (such as motion map, vectorial and graphical, yielding 27 multiple-choice items concerning four central concepts underpinning the force concept: Newton’s first, second, and third laws, and gravitation. We provide some evidence for the validity and reliability of the R-FCI; this analysis is limited to the student population of one Finnish high school. The students took the R-FCI at the beginning and at the end of their first high school physics course. We found that students’ (n=168 representational consistency (whether scientifically correct or not varied considerably depending on the concept. On average, representational consistency and scientifically correct understanding increased during the instruction, although in the post-test only a few students performed consistently both in terms of representations and scientifically correct understanding. We also compared students’ (n=87 results of the R-FCI and the FCI, and found that they correlated quite well.

  10. Multiplicities and parton dynamics

    International Nuclear Information System (INIS)

    Knuteson, R.O.

    1987-01-01

    The production of strongly interacting particles from the annihilation of electrons and positrons at high energies is studied, with emphasis on the multiplicity, or number, of particles produced. A probabilistic branching model based on the leading log approximation in QCD is formulated to predict the evolution of particle number with the energy of collision. Direct integration of a master equation for the probabilities allows a comparison to the experimentally observed particle distribution. The production of strongly interacting particles from proton-antiproton collisions is also considered. A model for the production of particles from parton-parton collisions is presented and the growth in multiplicity with energy demonstrated

  11. Detecting a Weak Association by Testing its Multiple Perturbations: a Data Mining Approach

    Science.gov (United States)

    Lo, Min-Tzu; Lee, Wen-Chung

    2014-05-01

    Many risk factors/interventions in epidemiologic/biomedical studies are of minuscule effects. To detect such weak associations, one needs a study with a very large sample size (the number of subjects, n). The n of a study can be increased but unfortunately only to an extent. Here, we propose a novel method which hinges on increasing sample size in a different direction-the total number of variables (p). We construct a p-based `multiple perturbation test', and conduct power calculations and computer simulations to show that it can achieve a very high power to detect weak associations when p can be made very large. As a demonstration, we apply the method to analyze a genome-wide association study on age-related macular degeneration and identify two novel genetic variants that are significantly associated with the disease. The p-based method may set a stage for a new paradigm of statistical tests.

  12. The Kansas Squat Test Modality Comparison: Free Weights vs. Smith Machine.

    Science.gov (United States)

    Luebbers, Paul E; Fry, Andrew C

    2016-08-01

    Luebbers, PE and Fry, AC. The Kansas squat test modality comparison: free weights vs. smith machine. J Strength Cond Res 30(8): 2186-2193, 2016-Standardized methods of testing power are instrumental in planning and implementing training regimens for many athletes, and also in tracking training adaptations. Previous work has demonstrated that the Kansas squat test (KST) is a valid test for measuring indices of mean and peak power when compared with the Wingate anaerobic cycle test. Although the KST was designed for use with a Smith machine (SM), many power athletes use free weights for training. The purpose of this study was to determine the feasibility of using free weights (FW) for the KST by comparing it with the SM modality. Twenty-three track and field athletes participated (mean ± SD; weight, 69.7 ± 10.6 kg; age, 20.1 ± 1.1 years) in this study. Each completed familiarization sessions with the FW and SM modalities before data collection. A 1-repetition maximum squat was also determined for both the FW and SM. Correlation coefficients indicated significant relationships between the FW KST and SM KST on measures of peak test power (r = 0.955; p 0.05) or posttest lactate (r = 0.109; p > 0.05). Paired samples t-tests indicated that the FW KST resulted in significantly higher measures of peak power and mean power (p ≤ 0.01), although no differences were observed for relative fatigue or lactate (p > 0.05). These data indicate that the FW KST is a valid and feasible alternative to the SM KST in measuring peak and mean power.

  13. Multiple preequilibrium decay processes

    International Nuclear Information System (INIS)

    Blann, M.

    1987-11-01

    Several treatments of multiple preequilibrium decay are reviewed with emphasis on the exciton and hybrid models. We show the expected behavior of this decay mode as a function of incident nucleon energy. The algorithms used in the hybrid model treatment are reviewed, and comparisons are made between predictions of the hybrid model and a broad range of experimental results. 24 refs., 20 figs

  14. A Comparison of Multidimensional Item Selection Methods in Simple and Complex Test Designs

    Directory of Open Access Journals (Sweden)

    Eren Halil ÖZBERK

    2017-03-01

    Full Text Available In contrast with the previous studies, this study employed various test designs (simple and complex which allow the evaluation of the overall ability score estimations across multiple real test conditions. In this study, four factors were manipulated, namely the test design, number of items per dimension, correlation between dimensions and item selection methods. Using the generated item and ability parameters, dichotomous item responses were generated in by using M3PL compensatory multidimensional IRT model with specified correlations. MCAT composite ability score accuracy was evaluated using absolute bias (ABSBIAS, correlation and the root mean square error (RMSE between true and estimated ability scores. The results suggest that the multidimensional test structure, number of item per dimension and correlation between dimensions had significant effect on item selection methods for the overall score estimations. For simple structure test design it was found that V1 item selection has the lowest absolute bias estimations for both long and short tests while estimating overall scores. As the model gets complex KL item selection method performed better than other two item selection method.

  15. Two-Sample Tests for High-Dimensional Linear Regression with an Application to Detecting Interactions.

    Science.gov (United States)

    Xia, Yin; Cai, Tianxi; Cai, T Tony

    2018-01-01

    Motivated by applications in genomics, we consider in this paper global and multiple testing for the comparisons of two high-dimensional linear regression models. A procedure for testing the equality of the two regression vectors globally is proposed and shown to be particularly powerful against sparse alternatives. We then introduce a multiple testing procedure for identifying unequal coordinates while controlling the false discovery rate and false discovery proportion. Theoretical justifications are provided to guarantee the validity of the proposed tests and optimality results are established under sparsity assumptions on the regression coefficients. The proposed testing procedures are easy to implement. Numerical properties of the procedures are investigated through simulation and data analysis. The results show that the proposed tests maintain the desired error rates under the null and have good power under the alternative at moderate sample sizes. The procedures are applied to the Framingham Offspring study to investigate the interactions between smoking and cardiovascular related genetic mutations important for an inflammation marker.

  16. Preliminary Process Theory does not validate the Comparison Question Test: A comment on Palmatier and Rovner

    NARCIS (Netherlands)

    Ben-Shakar, G.; Gamer, M.; Iacono, W.; Meijer, E.; Verschuere, B.

    2015-01-01

    Palmatier and Rovner (2015) attempt to establish the construct validity of the Comparison Question Test (CQT) by citing extensive research ranging from modern neuroscience to memory and psychophysiology. In this comment we argue that merely citing studies on the preliminary process theory (PPT) of

  17. Comparisons of treatment means when factors do not interact in two-factorial studies

    KAUST Repository

    Wei, Jiawei; Carroll, Raymond J.; Harden, Kathryn K.; Wu, Guoyao

    2011-01-01

    Scientists in the fields of nutrition and other biological sciences often design factorial studies to test the hypotheses of interest and importance. In the case of two-factorial studies, it is widely recognized that the analysis of factor effects is generally based on treatment means when the interaction of the factors is statistically significant, and involves multiple comparisons of treatment means. However, when the two factors do not interact, a common understanding among biologists is that comparisons among treatment means cannot or should not be made. Here, we bring this misconception into the attention of researchers. Additionally, we indicate what kind of comparisons among the treatment means can be performed when there is a nonsignificant interaction among two factors. Such information should be useful in analyzing the experimental data and drawing meaningful conclusions.

  18. Comparisons of treatment means when factors do not interact in two-factorial studies

    KAUST Repository

    Wei, Jiawei

    2011-05-06

    Scientists in the fields of nutrition and other biological sciences often design factorial studies to test the hypotheses of interest and importance. In the case of two-factorial studies, it is widely recognized that the analysis of factor effects is generally based on treatment means when the interaction of the factors is statistically significant, and involves multiple comparisons of treatment means. However, when the two factors do not interact, a common understanding among biologists is that comparisons among treatment means cannot or should not be made. Here, we bring this misconception into the attention of researchers. Additionally, we indicate what kind of comparisons among the treatment means can be performed when there is a nonsignificant interaction among two factors. Such information should be useful in analyzing the experimental data and drawing meaningful conclusions.

  19. A fast multilocus test with adaptive SNP selection for large-scale genetic-association studies

    KAUST Repository

    Zhang, Han

    2013-09-11

    As increasing evidence suggests that multiple correlated genetic variants could jointly influence the outcome, a multilocus test that aggregates association evidence across multiple genetic markers in a considered gene or a genomic region may be more powerful than a single-marker test for detecting susceptibility loci. We propose a multilocus test, AdaJoint, which adopts a variable selection procedure to identify a subset of genetic markers that jointly show the strongest association signal, and defines the test statistic based on the selected genetic markers. The P-value from the AdaJoint test is evaluated by a computationally efficient algorithm that effectively adjusts for multiple-comparison, and is hundreds of times faster than the standard permutation method. Simulation studies demonstrate that AdaJoint has the most robust performance among several commonly used multilocus tests. We perform multilocus analysis of over 26,000 genes/regions on two genome-wide association studies of pancreatic cancer. Compared with its competitors, AdaJoint identifies a much stronger association between the gene CLPTM1L and pancreatic cancer risk (6.0 × 10(-8)), with the signal optimally captured by two correlated single-nucleotide polymorphisms (SNPs). Finally, we show AdaJoint as a powerful tool for mapping cis-regulating methylation quantitative trait loci on normal breast tissues, and find many CpG sites whose methylation levels are jointly regulated by multiple SNPs nearby.

  20. Random number generators tested on quantum Monte Carlo simulations.

    Science.gov (United States)

    Hongo, Kenta; Maezono, Ryo; Miura, Kenichi

    2010-08-01

    We have tested and compared several (pseudo) random number generators (RNGs) applied to a practical application, ground state energy calculations of molecules using variational and diffusion Monte Carlo metheds. A new multiple recursive generator with 8th-order recursion (MRG8) and the Mersenne twister generator (MT19937) are tested and compared with the RANLUX generator with five luxury levels (RANLUX-[0-4]). Both MRG8 and MT19937 are proven to give the same total energy as that evaluated with RANLUX-4 (highest luxury level) within the statistical error bars with less computational cost to generate the sequence. We also tested the notorious implementation of linear congruential generator (LCG), RANDU, for comparison. (c) 2010 Wiley Periodicals, Inc.

  1. Autologous hematopoietic stem cell transplantation in relapsing-remitting multiple sclerosis: comparison with secondary progressive multiple sclerosis.

    Science.gov (United States)

    Casanova, Bonaventura; Jarque, Isidro; Gascón, Francisco; Hernández-Boluda, Juan Carlos; Pérez-Miralles, Francisco; de la Rubia, Javier; Alcalá, Carmen; Sanz, Jaime; Mallada, Javier; Cervelló, Angeles; Navarré, Arantxa; Carcelén-Gadea, María; Boscá, Isabel; Gil-Perotin, Sara; Solano, Carlos; Sanz, Miguel Angel; Coret, Francisco

    2017-07-01

    The main objective of our work is to describe the long-term results of myeloablative autologous hematopoietic stem cell transplant (AHSCT) in multiple sclerosis patients. Patients that failed to conventional therapies for multiple sclerosis (MS) underwent an approved protocol for AHSCT, which consisted of peripheral blood stem cell mobilization with cyclophosphamide and granulocyte colony-stimulating factor (G-CSF), followed by a conditioning regimen of BCNU, Etoposide, Ara-C, Melphalan IV, plus Rabbit Thymoglobulin. Thirty-eight MS patients have been transplanted since 1999. Thirty-one patients have been followed for more than 2 years (mean 8.4 years). There were 22 relapsing-remitting multiple sclerosis (RRMS) patients and 9 secondary progressive multiple sclerosis (SPMS) patients. No death related to AHSCT. A total of 10 patients (32.3%) had at least one relapse during post-AHSCT evolution, 6 patients in the RRMS group (27.2%) and 4 in the SPMS group (44.4%). After AHSCT, 7 patients (22.6%) experienced progression of disability, all within SP form. By contrast, no patients with RRMS experienced worsening of disability after a median follow-up of 5.4 years, 60% of them showed a sustained reduction in disability (SRD), defined as the improvement of 1.0 point in the expanded disability status scale (EDSS) sustains for 6 months (0.5 in cases of EDSS ≥ 5.5). The only clinical variable that predicted a poor response to AHSCT was a high EDSS in the year before transplant. AHSCT using the BEAM-ATG scheme is safe and efficacious to control the aggressive forms of RRMS.

  2. Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis.

    Science.gov (United States)

    Rosenblum, Uri; Melzer, Itshak

    2017-01-01

    About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http

  3. I just ran a thousand analyses: benefits of multiple testing in understanding equivocal evidence on gene-environment interactions.

    Directory of Open Access Journals (Sweden)

    Vera E Heininga

    Full Text Available In psychiatric genetics research, the volume of ambivalent findings on gene-environment interactions (G x E is growing at an accelerating pace. In response to the surging suspicions of systematic distortion, we challenge the notion of chance capitalization as a possible contributor. Beyond qualifying multiple testing as a mere methodological issue that, if uncorrected, leads to chance capitalization, we advance towards illustrating the potential benefits of multiple tests in understanding equivocal evidence in genetics literature.We focused on the interaction between the serotonin-transporter-linked promotor region (5-HTTLPR and childhood adversities with regard to depression. After testing 2160 interactions with all relevant measures available within the Dutch population study of adolescents TRAILS, we calculated percentages of significant (p < .05 effects for several subsets of regressions. Using chance capitalization (i.e. overall significance rate of 5% alpha and randomly distributed findings as a competing hypothesis, we expected more significant effects in the subsets of regressions involving: 1 interview-based instead of questionnaire-based measures; 2 abuse instead of milder childhood adversities; and 3 early instead of later adversities. Furthermore, we expected equal significance percentages across 4 male and female subsamples, and 5 various genotypic models of 5-HTTLPR.We found differences in the percentages of significant interactions among the subsets of analyses, including those regarding sex-specific subsamples and genetic modeling, but often in unexpected directions. Overall, the percentage of significant interactions was 7.9% which is only slightly above the 5% that might be expected based on chance.Taken together, multiple testing provides a novel approach to better understand equivocal evidence on G x E, showing that methodological differences across studies are a likely reason for heterogeneity in findings - but chance

  4. Comparison of a nonlinear dynamic model of a piping system to test data

    International Nuclear Information System (INIS)

    Blakely, K.D.; Howard, G.E.; Walton, W.B.; Johnson, B.A.; Chitty, D.E.

    1983-01-01

    Response of a nonlinear finite element model of the Heissdampfreaktor recirculation piping loop (URL) was compared to measured data, representing the physical benchmarking of a nonlinear model. Analysis-test comparisons of piping response are presented for snapback tests that induced extreme nonlinear behavior of the URL system. Nonlinearities in the system are due to twelve swaybraces (pipe supports) that possessed nonlinear force-deflection characteristics. These nonlinearities distorted system damping estimates made by using the half-power bandwidth method on Fourier transforms of measured accelerations, with the severity of distortion increasing with increasing degree of nonlinearity. Time domain methods, which are not so severely affected by the presence of nonlinearities, were used to compute system damping ratios. Nonlinear dynamic analyses were accurately and efficiently performed using the pseudo-force technique and the finite element program MSC/NASTRAN. Measured damping was incorporated into the model for snapback simulations. Acceleration time histories, acceleration Fourier transforms, and swaybrace force time histories of the nonlinear model, plus several linear models, were compared to test measurements. The nonlinear model predicted three-fourths of the measured peak accelerations to within 50%, half of the accelerations to within 25%, and one-fifth of the accelerations to within 10%. This nonlinear model predicted accelerations (in the time and frequency domains) and swaybrace forces much better than did any of the linear models, demonstrating the increased accuracy resulting from properly simulating nonlinear support behavior. In addition, earthquake response comparisons were made between the experimentally validated nonlinear model and a linear model. Significantly lower element stresses were predicted for the nonlinear model, indicating the potential usefulness of nonlinear simulations in piping design assessments. (orig.)

  5. Attention should be given to multiplicity issues in systematic reviews

    DEFF Research Database (Denmark)

    Bender, R.; Bunce, C.; Clarke, M.

    2008-01-01

    OBJECTIVE: The objective of this paper is to describe the problem of multiple comparisons in systematic reviews and to provide some guidelines on how to deal with it in practice. STUDY DESIGN AND SETTING: We describe common reasons for multiplicity in systematic reviews, and present some examples...

  6. Assessment of Personality Types and Locus of Control in Multiple Sclerosis Patients

    Directory of Open Access Journals (Sweden)

    Sh. Mazaheri

    2008-07-01

    Full Text Available Introduction & Objective: Multiple sclerosis (MS is an autoimmune disease with unknown cause. MS is one of the disabling neurologic diseases in adult especially young range that myelin part of central nervous system (CNS is destructed. The aim of this study was assessment of types A and B personality and internal and external locus of control in multiple sclerosis (MS patients and comparison of the results with control group.Materials & Methods: In a case-control study, 30 patients with MS and 30 normal persons as control group evaluated with neurological examination, Rotter locus of control test and Friedman-Rosenman questionnaire for detection of types A and B personality. We employed to analyze the results.Results: 43 percent and 57 percent of MS patients had internal and external locus of control respectively. 63 percent and 37 percent of MS patients had type A and B personality respectively. 60 percent and 40 percent of control group had internal and external locus of control respectively. 20 percent and 80 percent of control group had type A and B personality respectively. Difference between personality type in two groups was significant (P<0.01.Conclusions: In this study, MS patients had more type A personality in comparison to control group.

  7. RELAP5/MOD2 blind calculation of GERDA small break test and data comparison

    International Nuclear Information System (INIS)

    Ogden, D.M.; Steiner, J.L.; Waterman, M.E.

    1985-01-01

    The Idaho National Engineering Laboratory (INEL), in support of the USNRC, has developed a RELAP5/MOD2 model of the GERDA facility to be used for analysis of the GERDA data, particularly relative to the phenomena of natural circulation and the boiler condenser mode of heat transfer. A blind calculation of GERDA Test 1605AA and a preliminary comparison with experimental data has been performed. The GERDA facility is a single loop integral facility with an electrically heated core. A general arrangement diagram of the facility is shown. The GERDA facility was designed for the performance of both separate effects and overall systems tests

  8. Diagnostic value of stool DNA testing for multiple markers of colorectal cancer and advanced adenoma: a meta-analysis.

    Science.gov (United States)

    Yang, Hua; Xia, Bing-Qing; Jiang, Bo; Wang, Guozhen; Yang, Yi-Peng; Chen, Hao; Li, Bing-Sheng; Xu, An-Gao; Huang, Yun-Bo; Wang, Xin-Ying

    2013-08-01

    The diagnostic value of stool DNA (sDNA) testing for colorectal neoplasms remains controversial. To compensate for the lack of large-scale unbiased population studies, a meta-analysis was performed to evaluate the diagnostic value of sDNA testing for multiple markers of colorectal cancer (CRC) and advanced adenoma. The PubMed, Science Direct, Biosis Review, Cochrane Library and Embase databases were systematically searched in January 2012 without time restriction. Meta-analysis was performed using a random-effects model using sensitivity, specificity, diagnostic OR (DOR), summary ROC curves, area under the curve (AUC), and 95% CIs as effect measures. Heterogeneity was measured using the χ(2) test and Q statistic; subgroup analysis was also conducted. A total of 20 studies comprising 5876 individuals were eligible. There was no heterogeneity for CRC, but adenoma and advanced adenoma harboured considerable heterogeneity influenced by risk classification and various detection markers. Stratification analysis according to risk classification showed that multiple markers had a high DOR for the high-risk subgroups of both CRC (sensitivity 0.759 [95% CI 0.711 to 0.804]; specificity 0.883 [95% CI 0.846 to 0.913]; AUC 0.906) and advanced adenoma (sensitivity 0.683 [95% CI 0.584 to 0.771]; specificity 0.918 [95% CI 0.866 to 0.954]; AUC 0.946) but not for the average-risk subgroups of either. In the methylation subgroup, sDNA testing had significantly higher DOR for CRC (sensitivity 0.753 [95% CI 0.685 to 0.812]; specificity 0.913 [95% CI 0.860 to 0.950]; AUC 0.918) and advanced adenoma (sensitivity 0.623 [95% CI 0.527 to 0.712]; specificity 0.926 [95% CI 0.882 to 0.958]; AUC 0.910) compared with the mutation subgroup. There was no significant heterogeneity among studies for subgroup analysis. sDNA testing for multiple markers had strong diagnostic significance for CRC and advanced adenoma in high-risk subjects. Methylation makers had more diagnostic value than mutation

  9. Automatic segmentation of male pelvic anatomy on computed tomography images: a comparison with multiple observers in the context of a multicentre clinical trial.

    Science.gov (United States)

    Geraghty, John P; Grogan, Garry; Ebert, Martin A

    2013-04-30

    This study investigates the variation in segmentation of several pelvic anatomical structures on computed tomography (CT) between multiple observers and a commercial automatic segmentation method, in the context of quality assurance and evaluation during a multicentre clinical trial. CT scans of two prostate cancer patients ('benchmarking cases'), one high risk (HR) and one intermediate risk (IR), were sent to multiple radiotherapy centres for segmentation of prostate, rectum and bladder structures according to the TROG 03.04 "RADAR" trial protocol definitions. The same structures were automatically segmented using iPlan software for the same two patients, allowing structures defined by automatic segmentation to be quantitatively compared with those defined by multiple observers. A sample of twenty trial patient datasets were also used to automatically generate anatomical structures for quantitative comparison with structures defined by individual observers for the same datasets. There was considerable agreement amongst all observers and automatic segmentation of the benchmarking cases for bladder (mean spatial variations segmenting a prostate with considerably more volume (mean +113.3%) than that automatically segmented. Similar results were seen across the twenty sample datasets, with disagreement between iPlan and observers dominant at the prostatic apex and superior part of the rectum, which is consistent with observations made during quality assurance reviews during the trial. This study has demonstrated quantitative analysis for comparison of multi-observer segmentation studies. For automatic segmentation algorithms based on image-registration as in iPlan, it is apparent that agreement between observer and automatic segmentation will be a function of patient-specific image characteristics, particularly for anatomy with poor contrast definition. For this reason, it is suggested that automatic registration based on transformation of a single reference dataset

  10. Analysis and Testing of Mobile Wireless Networks

    Science.gov (United States)

    Alena, Richard; Evenson, Darin; Rundquist, Victor; Clancy, Daniel (Technical Monitor)

    2002-01-01

    Wireless networks are being used to connect mobile computing elements in more applications as the technology matures. There are now many products (such as 802.11 and 802.11b) which ran in the ISM frequency band and comply with wireless network standards. They are being used increasingly to link mobile Intranet into Wired networks. Standard methods of analyzing and testing their performance and compatibility are needed to determine the limits of the technology. This paper presents analytical and experimental methods of determining network throughput, range and coverage, and interference sources. Both radio frequency (BE) domain and network domain analysis have been applied to determine wireless network throughput and range in the outdoor environment- Comparison of field test data taken under optimal conditions, with performance predicted from RF analysis, yielded quantitative results applicable to future designs. Layering multiple wireless network- sooners can increase performance. Wireless network components can be set to different radio frequency-hopping sequences or spreading functions, allowing more than one sooner to coexist. Therefore, we ran multiple 802.11-compliant systems concurrently in the same geographical area to determine interference effects and scalability, The results can be used to design of more robust networks which have multiple layers of wireless data communication paths and provide increased throughput overall.

  11. Shared Authentic Leadership in Research Teams: Testing a Multiple Mediation Model.

    Science.gov (United States)

    Guenter, Hannes; Gardner, William L; Davis McCauley, Kelly; Randolph-Seng, Brandon; Prabhu, Veena P

    2017-12-01

    Research teams face complex leadership and coordination challenges. We propose shared authentic leadership (SAL) as a timely approach to addressing these challenges. Drawing from authentic and functional leadership theories, we posit a multiple mediation model that suggests three mechanisms whereby SAL influences team effectiveness: shared mental models (SMM), team trust, and team coordination. To test our hypotheses, we collected survey data on leadership and teamwork within 142 research teams that recently published an article in a peer-reviewed management journal. The results indicate team coordination represents the primary mediating mechanism accounting for the relationship between SAL and research team effectiveness. While teams with high trust and SMM felt more successful and were more satisfied, they were less successful in publishing in high-impact journals. We also found the four SAL dimensions (i.e., self-awareness, relational transparency, balanced processing, and internalized moral perspective) to associate differently with team effectiveness.

  12. Nurse-led immunotreatment DEcision Coaching In people with Multiple Sclerosis (DECIMS) - Feasibility testing, pilot randomised controlled trial and mixed methods process evaluation.

    Science.gov (United States)

    Rahn, A C; Köpke, S; Backhus, I; Kasper, J; Anger, K; Untiedt, B; Alegiani, A; Kleiter, I; Mühlhauser, I; Heesen, C

    2018-02-01

    Treatment decision-making is complex for people with multiple sclerosis. Profound information on available options is virtually not possible in regular neurologist encounters. The "nurse decision coach model" was developed to redistribute health professionals' tasks in supporting immunotreatment decision-making following the principles of informed shared decision-making. To test the feasibility of a decision coaching programme and recruitment strategies to inform the main trial. Feasibility testing and parallel pilot randomised controlled trial, accompanied by a mixed methods process evaluation. Two German multiple sclerosis university centres. People with suspected or relapsing-remitting multiple sclerosis facing immunotreatment decisions on first line drugs were recruited. Randomisation to the intervention (n = 38) or control group (n = 35) was performed on a daily basis. Quantitative and qualitative process data were collected from people with multiple sclerosis, nurses and physicians. We report on the development and piloting of the decision coaching programme. It comprises a training course for multiple sclerosis nurses and the coaching intervention. The intervention consists of up to three structured nurse-led decision coaching sessions, access to an evidence-based online information platform (DECIMS-Wiki) and a final physician consultation. After feasibility testing, a pilot randomised controlled trial was performed. People with multiple sclerosis were randomised to the intervention or control group. The latter had also access to the DECIMS-Wiki, but received otherwise care as usual. Nurses were not blinded to group assignment, while people with multiple sclerosis and physicians were. The primary outcome was 'informed choice' after six months including the sub-dimensions' risk knowledge (after 14 days), attitude concerning immunotreatment (after physician consultation), and treatment uptake (after six months). Quantitative process evaluation data

  13. 'Multiple-test' approach to the laboratory diagnosis of tuberculosis -perception of medical doctors from Ujjain, India.

    Science.gov (United States)

    Purohit, Manju Raj; Sharma, Megha; Rosales-Klintz, Senia; Lundborg, Cecilia Stålsby

    2015-08-11

    Delay in diagnosis is one of the most important factors for the control of tuberculosis (TB) in endemic countries like India. As laboratory diagnosis is the mainstay for identification of active disease, we aim to explore and understand the opinions of medical doctors about the laboratory diagnosis of TB in Ujjain, India. Sixteen qualified specialist medical doctors from Ujjain were purposefully selected for the study. Individual interviews with the doctors (13 men and 3 women), were conducted. As one interview could not be completed, data from 15 interviews were analyzed using manifest and latent content analysis. Based on perception of the doctors, the theme; 'challenges and need for the laboratory diagnosis of TB' emerged from the following subthemes: (i) Relationship between basic element of the TB diseases process such as 'Symptoms prior to diagnoses' and 'Clinical characteristics of TB', which were not specific enough to diagnose TB (ii) The prevailing conditions such as lack of explicit diagnostic tools, lead to the doctors using the 'multiple tests' or 'empiric treatment' approach (iii) The doctors proposed that there is a need for access to a rapid, single and simple diagnostic test, and a need for awareness and knowledge of the practitioners regarding specific TB investigations, and early referral to improve the situation at resource-limited settings. The medical specialists use a 'multiple test' or 'empiric treatment' approach to diagnose TB. According to the participants, there is a low dependence and uptake of the available laboratory TB investigations by medical practitioners. There is an urgent need to have a specific, simple and reliable test, and a protocol, to improve diagnosis of TB and to prevent development of resistant TB.

  14. Murasaki: a fast, parallelizable algorithm to find anchors from multiple genomes.

    Directory of Open Access Journals (Sweden)

    Kris Popendorf

    Full Text Available BACKGROUND: With the number of available genome sequences increasing rapidly, the magnitude of sequence data required for multiple-genome analyses is a challenging problem. When large-scale rearrangements break the collinearity of gene orders among genomes, genome comparison algorithms must first identify sets of short well-conserved sequences present in each genome, termed anchors. Previously, anchor identification among multiple genomes has been achieved using pairwise alignment tools like BLASTZ through progressive alignment tools like TBA, but the computational requirements for sequence comparisons of multiple genomes quickly becomes a limiting factor as the number and scale of genomes grows. METHODOLOGY/PRINCIPAL FINDINGS: Our algorithm, named Murasaki, makes it possible to identify anchors within multiple large sequences on the scale of several hundred megabases in few minutes using a single CPU. Two advanced features of Murasaki are (1 adaptive hash function generation, which enables efficient use of arbitrary mismatch patterns (spaced seeds and therefore the comparison of multiple mammalian genomes in a practical amount of computation time, and (2 parallelizable execution that decreases the required wall-clock and CPU times. Murasaki can perform a sensitive anchoring of eight mammalian genomes (human, chimp, rhesus, orangutan, mouse, rat, dog, and cow in 21 hours CPU time (42 minutes wall time. This is the first single-pass in-core anchoring of multiple mammalian genomes. We evaluated Murasaki by comparing it with the genome alignment programs BLASTZ and TBA. We show that Murasaki can anchor multiple genomes in near linear time, compared to the quadratic time requirements of BLASTZ and TBA, while improving overall accuracy. CONCLUSIONS/SIGNIFICANCE: Murasaki provides an open source platform to take advantage of long patterns, cluster computing, and novel hash algorithms to produce accurate anchors across multiple genomes with

  15. Enzyme sequence similarity improves the reaction alignment method for cross-species pathway comparison

    Energy Technology Data Exchange (ETDEWEB)

    Ovacik, Meric A. [Chemical and Biochemical Engineering Department, Rutgers University, Piscataway, NJ 08854 (United States); Androulakis, Ioannis P., E-mail: yannis@rci.rutgers.edu [Chemical and Biochemical Engineering Department, Rutgers University, Piscataway, NJ 08854 (United States); Biomedical Engineering Department, Rutgers University, Piscataway, NJ 08854 (United States)

    2013-09-15

    Pathway-based information has become an important source of information for both establishing evolutionary relationships and understanding the mode of action of a chemical or pharmaceutical among species. Cross-species comparison of pathways can address two broad questions: comparison in order to inform evolutionary relationships and to extrapolate species differences used in a number of different applications including drug and toxicity testing. Cross-species comparison of metabolic pathways is complex as there are multiple features of a pathway that can be modeled and compared. Among the various methods that have been proposed, reaction alignment has emerged as the most successful at predicting phylogenetic relationships based on NCBI taxonomy. We propose an improvement of the reaction alignment method by accounting for sequence similarity in addition to reaction alignment method. Using nine species, including human and some model organisms and test species, we evaluate the standard and improved comparison methods by analyzing glycolysis and citrate cycle pathways conservation. In addition, we demonstrate how organism comparison can be conducted by accounting for the cumulative information retrieved from nine pathways in central metabolism as well as a more complete study involving 36 pathways common in all nine species. Our results indicate that reaction alignment with enzyme sequence similarity results in a more accurate representation of pathway specific cross-species similarities and differences based on NCBI taxonomy.

  16. Enzyme sequence similarity improves the reaction alignment method for cross-species pathway comparison

    International Nuclear Information System (INIS)

    Ovacik, Meric A.; Androulakis, Ioannis P.

    2013-01-01

    Pathway-based information has become an important source of information for both establishing evolutionary relationships and understanding the mode of action of a chemical or pharmaceutical among species. Cross-species comparison of pathways can address two broad questions: comparison in order to inform evolutionary relationships and to extrapolate species differences used in a number of different applications including drug and toxicity testing. Cross-species comparison of metabolic pathways is complex as there are multiple features of a pathway that can be modeled and compared. Among the various methods that have been proposed, reaction alignment has emerged as the most successful at predicting phylogenetic relationships based on NCBI taxonomy. We propose an improvement of the reaction alignment method by accounting for sequence similarity in addition to reaction alignment method. Using nine species, including human and some model organisms and test species, we evaluate the standard and improved comparison methods by analyzing glycolysis and citrate cycle pathways conservation. In addition, we demonstrate how organism comparison can be conducted by accounting for the cumulative information retrieved from nine pathways in central metabolism as well as a more complete study involving 36 pathways common in all nine species. Our results indicate that reaction alignment with enzyme sequence similarity results in a more accurate representation of pathway specific cross-species similarities and differences based on NCBI taxonomy

  17. Comparison of Aerobic Performance Testing Protocols in Elite Male Wheelchair Basketball Players

    Directory of Open Access Journals (Sweden)

    Molik Bartosz

    2017-12-01

    Full Text Available In wheelchair sports, aerobic performance is commonly assessed with the use of an arm crank ergometer (ACE, a wheelchair ergometer (WCE or a wheelchair treadmill (WCT. There are different protocols to identify peak oxygen uptake in wheelchair sports; however, only a few protocols have been applied to evaluate these conditions in wheelchair basketball players. The purpose of this study was to compare physiological responses during maximal exercise testing with the use of ACE and WCT in wheelchair basketball players. Twelve elite male wheelchair basketball players participated in this study. The research was performed during a training camp of the Polish National Wheelchair Basketball Team. The study participants were divided into two functional categories: A (players with class 1.0 - 2.5 and B (players with class 3.0 - 4.5. Two main maximal exercise tests, i.e. wheelchair treadmill stress test (WCT test and arm crank ergometer stress test (ACE test were used to evaluate aerobic performance of the players. There were no statistically significant differences in aerobic tests between the players from both groups. The comparison of results achieved in two aerobic tests performed on WCT and ACE did not reveal any significant differences between the analyzed variables (peak heart rate (HRpeak, peak oxygen uptake (VO2peak, minute ventilation (VE, anaerobic threshold (AT, lactate concentration (LApeak, and a drop in lactate concentration (%LA. Strong correlations between results achieved in WCT and ACE tests were found for VO2peak, VE and LApeak. The main conclusion of the study is that both WCT and ACE tests may be useful when determining aerobic capacity of wheelchair basketball players. Moreover, both protocols can be used by athletes regardless of their functional capabilities and types of impairment.

  18. Multiplicity distributions in high-energy neutrino interactions

    International Nuclear Information System (INIS)

    Chapman, J.W.; Coffin, C.T.; Diamond, R.N.; French, H.; Louis, W.; Roe, B.P.; Seidl, A.A.; Vander Velde, J.C.; Berge, J.P.; Bogert, D.V.; DiBianca, F.A.; Cundy, D.C.; Dunaitsev, A.; Efremenko, V.; Ermolov, P.; Fowler, W.; Hanft, R.; Harigel, G.; Huson, F.R.; Kolganov, V.; Mukhin, A.; Nezrick, F.A.; Rjabov, Y.; Scott, W.G.; Smart, W.

    1976-01-01

    Results from the Fermilab 15-ft bubble chamber on the charged-particle multiplicity distributions produced in high-energy charged-current neutrino-proton interactions are presented. Comparisons are made to γp, ep, μp, and inclusive pp scattering. The mean hadronic multiplicity appears to depend only on the mass of the excited hadronic state, independent of the mode of excitation. A fit to the neutrino data gives = (1.09+-0.38) +(1.09+-0.03)lnW 2

  19. Accelerating Multiple Compound Comparison Using LINGO-Based Load-Balancing Strategies on Multi-GPUs

    OpenAIRE

    Lin, Chun-Yuan; Wang, Chung-Hung; Hung, Che-Lun; Lin, Yu-Shiang

    2015-01-01

    Compound comparison is an important task for the computational chemistry. By the comparison results, potential inhibitors can be found and then used for the pharmacy experiments. The time complexity of a pairwise compound comparison is O(n 2), where n is the maximal length of compounds. In general, the length of compounds is tens to hundreds, and the computation time is small. However, more and more compounds have been synthesized and extracted now, even more than tens of millions. Therefore,...

  20. Dynamic Testing of Analogical Reasoning in 5- to 6-Year-Olds : Multiple-Choice Versus Constructed-Response Training Items

    NARCIS (Netherlands)

    Stevenson, C.E.; Heiser, W.J.; Resing, W.C.M.

    2016-01-01

    Multiple-choice (MC) analogy items are often used in cognitive assessment. However, in dynamic testing, where the aim is to provide insight into potential for learning and the learning process, constructed-response (CR) items may be of benefit. This study investigated whether training with CR or MC

  1. Concurrent conditional clustering of multiple networks: COCONETS.

    Directory of Open Access Journals (Sweden)

    Sabrina Kleessen

    Full Text Available The accumulation of high-throughput data from different experiments has facilitated the extraction of condition-specific networks over the same set of biological entities. Comparing and contrasting of such multiple biological networks is in the center of differential network biology, aiming at determining general and condition-specific responses captured in the network structure (i.e., included associations between the network components. We provide a novel way for comparison of multiple networks based on determining network clustering (i.e., partition into communities which is optimal across the set of networks with respect to a given cluster quality measure. To this end, we formulate the optimization-based problem of concurrent conditional clustering of multiple networks, termed COCONETS, based on the modularity. The solution to this problem is a clustering which depends on all considered networks and pinpoints their preserved substructures. We present theoretical results for special classes of networks to demonstrate the implications of conditionality captured by the COCONETS formulation. As the problem can be shown to be intractable, we extend an existing efficient greedy heuristic and applied it to determine concurrent conditional clusters on coexpression networks extracted from publically available time-resolved transcriptomics data of Escherichia coli under five stresses as well as on metabolite correlation networks from metabolomics data set from Arabidopsis thaliana exposed to eight environmental conditions. We demonstrate that the investigation of the differences between the clustering based on all networks with that obtained from a subset of networks can be used to quantify the specificity of biological responses. While a comparison of the Escherichia coli coexpression networks based on seminal properties does not pinpoint biologically relevant differences, the common network substructures extracted by COCONETS are supported by

  2. A multiple treatment comparison meta-analysis of monoamine oxidase type B inhibitors for Parkinson's disease.

    Science.gov (United States)

    Binde, C D; Tvete, I F; Gåsemyr, J; Natvig, B; Klemp, M

    2018-05-30

    To the best of our knowledge, there are no systematic reviews or meta-analyses that compare rasagiline, selegiline and safinamide. Therefore, we aimed to perform a drug class review comparing all available monoamine oxidase type B (MAO-B) inhibitors in a multiple treatment comparison. We performed a systematic literature search to identify randomized controlled trials assessing the efficacy of MAO-B inhibitors in patients with Parkinson's disease. MAO-B inhibitors were evaluated either as monotherapy or in combination with levodopa or dopamine agonists. Endpoints of interest were change in the Unified Parkinson's Disease Rating Scale (UPDRS) score and serious adverse events. We estimated the relative effect of each MAO-B inhibitor versus the comparator drug by creating three networks of direct and indirect comparisons. For each of the networks, we considered a joint model. The systematic literature search and study selection process identified 27 publications eligible for our three network analyses. We found the relative effects of rasagiline, safinamide and selegiline treatment given alone and compared to placebo in a model without explanatory variables to be 1.560 (1.409, 1.734), 1.449 (0.873, 2.413) and 1.532 (1.337, 1.757) respectively. We also found all MAO-B inhibitors to be efficient when given together with levodopa. When ranking the MAO-B inhibitors given in combination with levodopa, selegiline was the most effective and rasagiline was the second best. All of the included MAO-B inhibitors were effective compared to placebo when given as monotherapy. Combination therapy with MAO-B inhibitors and levodopa showed that all three MAO-B inhibitors were effective compared to placebo, but selegiline was the most effective drug. © 2018 The British Pharmacological Society.

  3. Communicating radon risk effectively: Radon testing in Maryland. Final report

    International Nuclear Information System (INIS)

    Desvousges, W.H.; Smith, V.K.; Rink, H.H.

    1988-10-01

    Two sets of materials and corresponding delivery strategies for communicating radon risk were evaluated, compared with a 'no-special-treatment' strategy in a comparison community. One community received radio public-service announcements and utility bill inserts. The second received these plus posters, local government sponsorship of a radon awareness week, and local slide presentations. The most-intensive efforts (multiple channels, multiple hits) were more effective than the less intensive effort, which had little impact compared with no special treatment. From a marketing perspective, the effort was very successful, increasing the share of homeowners who tested for radon from 5% to 15%. This may not be viewed as sufficiently effective from a public-health perspective, however

  4. Comparison of test protocols for standard room/corner tests

    Science.gov (United States)

    R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens

    1998-01-01

    As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...

  5. Power Hardware-in-the-Loop Testing of Multiple Photovoltaic Inverters' Volt-Var Control with Real-Time Grid Model

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Nelson, Austin; Hoke, Anderson

    2016-12-12

    Traditional testing methods fall short in evaluating interactions between multiple smart inverters providing advanced grid support functions due to the fact that such interactions largely depend on their placements on the electric distribution systems with impedances between them. Even though significant concerns have been raised by the utilities on the effects of such interactions, little effort has been made to evaluate them. In this paper, power hardware-in-the-loop (PHIL) based testing was utilized to evaluate autonomous volt-var operations of multiple smart photovoltaic (PV) inverters connected to a simple distribution feeder model. The results provided in this paper show that depending on volt-var control (VVC) parameters and grid parameters, interaction between inverters and between the inverter and the grid is possible in some extreme cases with very high VVC slopes, fast response times and large VVC response delays.

  6. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    International Nuclear Information System (INIS)

    Woodman, N.D.; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-01-01

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study

  7. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Woodman, N.D., E-mail: n.d.woodman@soton.ac.uk; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-04-15

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study.

  8. Unified Sequence-Based Association Tests Allowing for Multiple Functional Annotations and Meta-analysis of Noncoding Variation in Metabochip Data.

    Science.gov (United States)

    He, Zihuai; Xu, Bin; Lee, Seunggeun; Ionita-Laza, Iuliana

    2017-09-07

    Substantial progress has been made in the functional annotation of genetic variation in the human genome. Integrative analysis that incorporates such functional annotations into sequencing studies can aid the discovery of disease-associated genetic variants, especially those with unknown function and located outside protein-coding regions. Direct incorporation of one functional annotation as weight in existing dispersion and burden tests can suffer substantial loss of power when the functional annotation is not predictive of the risk status of a variant. Here, we have developed unified tests that can utilize multiple functional annotations simultaneously for integrative association analysis with efficient computational techniques. We show that the proposed tests significantly improve power when variant risk status can be predicted by functional annotations. Importantly, when functional annotations are not predictive of risk status, the proposed tests incur only minimal loss of power in relation to existing dispersion and burden tests, and under certain circumstances they can even have improved power by learning a weight that better approximates the underlying disease model in a data-adaptive manner. The tests can be constructed with summary statistics of existing dispersion and burden tests for sequencing data, therefore allowing meta-analysis of multiple studies without sharing individual-level data. We applied the proposed tests to a meta-analysis of noncoding rare variants in Metabochip data on 12,281 individuals from eight studies for lipid traits. By incorporating the Eigen functional score, we detected significant associations between noncoding rare variants in SLC22A3 and low-density lipoprotein and total cholesterol, associations that are missed by standard dispersion and burden tests. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  9. To Show or Not to Show: The Effects of Item Stems and Answer Options on Performance on a Multiple-Choice Listening Comprehension Test

    Science.gov (United States)

    Yanagawa, Kozo; Green, Anthony

    2008-01-01

    The purpose of this study is to examine whether the choice between three multiple-choice listening comprehension test formats results in any difference in listening comprehension test performance. The three formats entail (a) allowing test takers to preview both the question stem and answer options prior to listening; (b) allowing test takers to…

  10. Clinical usefulness of serum free light chains measurement in patients with multiple myeloma: comparative analysis of two different tests

    Directory of Open Access Journals (Sweden)

    Tadeusz Kubicki

    2017-01-01

    Full Text Available Introduction: There are two commercially available tests for measurement of serum free light chains (sFLC in multiple myeloma (MM patients – Freelite and N Latex FLC. The aim of this study was to perform an assessment and direct comparison of the usefulness of the methods in routine clinical practice.Methods: 40 refractory/relapsed MM patients underwent routine disease activity assessment studies, along with sFLC analysis using both assays. Correlation and concordance between the tests and sensitivity of studied methods of sFLC assessment were established. Special attention was focused on sFLC results in patients finally evaluated after completing the treatment. Results: A weak correlation for the measurement of both κ [Passing–Bablok slope (PB = 0.7681] and λ chains [(PB = 1.542] was found. Using Bland–Altman plots, a bias of 0.0467 (κ and -0.2133 (λ between the measurements was documented. The concordance coefficient equaled 0.87 for κ, 0.62 for λ and 0.52 for κ/λ ratio. Ten patients had an abnormal Freelite assay κ/λ ratio and normal N Latex FLC κ/λ ratio. Three of these patients had negative serum protein electrophoresis results and fulfilled diagnostic criteria of stringent complete remission (sCR according to N Latex FLC (but not according to Freelite. When the κ/λ ratio obtained by both methods was compared to patients’ serum/urine protein electrophoresis and immunofixation results, sensitivity of Freelite and N Latex FLC was established to be 62.5% and 41%, respectively. Conclusions: There was no strong correlation or concordance between the two assays, and the sensitivity in terms of sFLC detection was different. This may cause problems when diagnosis of sCR is considered.

  11. Autonomic dysfunction in different subtypes of multiple system atrophy.

    Science.gov (United States)

    Schmidt, Claudia; Herting, Birgit; Prieur, Silke; Junghanns, Susann; Schweitzer, Katherine; Globas, Christoph; Schöls, Ludger; Reichmann, Heinz; Berg, Daniela; Ziemssen, Tjalf

    2008-09-15

    Multiple system atrophy (MSA) can clinically be divided into the cerebellar (MSA-C) and the parkinsonian (MSA-P) variant. However, till now, it is unknown whether autonomic dysfunction in these two entities differs regarding severity and profile. We compared the pattern of autonomic dysfunction in 12 patients with MSA-C and 26 with MSA-P in comparison with 27 age- and sex-matched healthy controls using a standard battery of autonomic function tests and a structured anamnesis of the autonomic nervous system. MSA-P patients complained significantly more often about the symptoms of autonomic dysfunctions than MSA-C patients, especially regarding vasomotor, secretomotor, and gastrointestinal subsystems. However, regarding cardiovascular, sudomotor pupil, urogenital, and sleep subsystems, there were no significant quantitative or qualitative differences as analyzed by autonomic anamnesis and testing. Our results suggest that there are only minor differences in the pattern of autonomic dysfunction between the two clinical MSA phenotypes. (c) 2007 Movement Disorder Society.

  12. Effectiveness comparison of partially executed t-way test suite based generated by existing strategies

    Science.gov (United States)

    Othman, Rozmie R.; Ahmad, Mohd Zamri Zahir; Ali, Mohd Shaiful Aziz Rashid; Zakaria, Hasneeza Liza; Rahman, Md. Mostafijur

    2015-05-01

    Consuming 40 to 50 percent of software development cost, software testing is one of the most resource consuming activities in software development lifecycle. To ensure an acceptable level of quality and reliability of a typical software product, it is desirable to test every possible combination of input data under various configurations. Due to combinatorial explosion problem, considering all exhaustive testing is practically impossible. Resource constraints, costing factors as well as strict time-to-market deadlines are amongst the main factors that inhibit such consideration. Earlier work suggests that sampling strategy (i.e. based on t-way parameter interaction or called as t-way testing) can be effective to reduce number of test cases without effecting the fault detection capability. However, for a very large system, even t-way strategy will produce a large test suite that need to be executed. In the end, only part of the planned test suite can be executed in order to meet the aforementioned constraints. Here, there is a need for test engineers to measure the effectiveness of partially executed test suite in order for them to assess the risk they have to take. Motivated by the abovementioned problem, this paper presents the effectiveness comparison of partially executed t-way test suite generated by existing strategies using tuples coverage method. Here, test engineers can predict the effectiveness of the testing process if only part of the original test cases is executed.

  13. gsSKAT: Rapid gene set analysis and multiple testing correction for rare-variant association studies using weighted linear kernels.

    Science.gov (United States)

    Larson, Nicholas B; McDonnell, Shannon; Cannon Albright, Lisa; Teerlink, Craig; Stanford, Janet; Ostrander, Elaine A; Isaacs, William B; Xu, Jianfeng; Cooney, Kathleen A; Lange, Ethan; Schleutker, Johanna; Carpten, John D; Powell, Isaac; Bailey-Wilson, Joan E; Cussenot, Olivier; Cancel-Tassin, Geraldine; Giles, Graham G; MacInnis, Robert J; Maier, Christiane; Whittemore, Alice S; Hsieh, Chih-Lin; Wiklund, Fredrik; Catalona, William J; Foulkes, William; Mandal, Diptasri; Eeles, Rosalind; Kote-Jarai, Zsofia; Ackerman, Michael J; Olson, Timothy M; Klein, Christopher J; Thibodeau, Stephen N; Schaid, Daniel J

    2017-05-01

    Next-generation sequencing technologies have afforded unprecedented characterization of low-frequency and rare genetic variation. Due to low power for single-variant testing, aggregative methods are commonly used to combine observed rare variation within a single gene. Causal variation may also aggregate across multiple genes within relevant biomolecular pathways. Kernel-machine regression and adaptive testing methods for aggregative rare-variant association testing have been demonstrated to be powerful approaches for pathway-level analysis, although these methods tend to be computationally intensive at high-variant dimensionality and require access to complete data. An additional analytical issue in scans of large pathway definition sets is multiple testing correction. Gene set definitions may exhibit substantial genic overlap, and the impact of the resultant correlation in test statistics on Type I error rate control for large agnostic gene set scans has not been fully explored. Herein, we first outline a statistical strategy for aggregative rare-variant analysis using component gene-level linear kernel score test summary statistics as well as derive simple estimators of the effective number of tests for family-wise error rate control. We then conduct extensive simulation studies to characterize the behavior of our approach relative to direct application of kernel and adaptive methods under a variety of conditions. We also apply our method to two case-control studies, respectively, evaluating rare variation in hereditary prostate cancer and schizophrenia. Finally, we provide open-source R code for public use to facilitate easy application of our methods to existing rare-variant analysis results. © 2017 WILEY PERIODICALS, INC.

  14. A comparison of CHENATH, the Nationwide House Energy Rating Scheme Simulation Engine, with measured test cell data

    Energy Technology Data Exchange (ETDEWEB)

    Delsante, A.E. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Highett, VIC (Australia). Div. of Building Construction and Engineering

    1995-12-31

    The Nationwide House Energy Rating Scheme (NatHERS) uses a simulation program as its reference tool to evaluate the energy demand of buildings. The Commonwealth Scientific Industrial Research Organisation (CSIRO) developed software called CHENATH, is a significantly enhanced version of the CHEETAH simulation program. As part of the NatHERS development process, it was considered important to subject CHENATH to further testing. Two separate evaluation projects were undertaken. This paper describes one of these projects. CHENATH was compared with measured data from three test cells with single glazing, double glazing and no glazing. The solar radiation comparisons led to an improved model that accounts for anisotropic diffuse radiation. CHENATH significantly under-predicted the heating energy, but conclusions are difficult to draw because the actual heater used was very different from that assumed by the program. Temperature comparisons in the free running single-glazed cell showed that CHENATH`s new glazing model preformed significantly better than the old model. This exercise has reinforced the need for extreme care in designing, monitoring and describing test cells and for modellers to interpret the data supplied correctly. (author). 4 tabs., 3 figs., 4 refs.

  15. Testing for nonrandom shape similarity between sister cells using automated shape comparison

    Science.gov (United States)

    Guo, Monica; Marshall, Wallace F.

    2009-02-01

    Several reports in the biological literature have indicated that when a living cell divides, the two daughter cells have a tendency to be mirror images of each other in terms of their overall cell shape. This phenomenon would be consistent with inheritance of spatial organization from mother cell to daughters. However the published data rely on a small number of examples that were visually chosen, raising potential concerns about inadvertent selection bias. We propose to revisit this issue using automated quantitative shape comparison methods which would have no contribution from the observer and which would allow statistical testing of similarity in large numbers of cells. In this report we describe a first order approach to the problem using rigid curve matching. Using test images, we compare a pointwise correspondence based distance metric with a chamfer matching strategy and find that the latter provides better correspondence and smaller distances between aligned curves, especially when we allow nonrigid deformation of the outlines in addition to rotation.

  16. Multiple comparisons in drug efficacy studies: scientific or marketing principles?

    Science.gov (United States)

    Leo, Jonathan

    2004-01-01

    When researchers design an experiment to compare a given medication to another medication, a behavioral therapy, or a placebo, the experiment often involves numerous comparisons. For instance, there may be several different evaluation methods, raters, and time points. Although scientifically justified, such comparisons can be abused in the interests of drug marketing. This article provides two recent examples of such questionable practices. The first involves the case of the arthritis drug celecoxib (Celebrex), where the study lasted 12 months but the authors only presented 6 months of data. The second case involves the NIMH Multimodal Treatment Study (MTA) study evaluating the efficacy of stimulant medication for attention-deficit hyperactivity disorder where ratings made by several groups are reported in contradictory fashion. The MTA authors have not clarified the confusion, at least in print, suggesting that the actual findings of the study may have played little role in the authors' reported conclusions.

  17. Multiple-Choice Testing Using Immediate Feedback--Assessment Technique (IF AT®) Forms: Second-Chance Guessing vs. Second-Chance Learning?

    Science.gov (United States)

    Merrel, Jeremy D.; Cirillo, Pier F.; Schwartz, Pauline M.; Webb, Jeffrey A.

    2015-01-01

    Multiple choice testing is a common but often ineffective method for evaluating learning. A newer approach, however, using Immediate Feedback Assessment Technique (IF AT®, Epstein Educational Enterprise, Inc.) forms, offers several advantages. In particular, a student learns immediately if his or her answer is correct and, in the case of an…

  18. Effects of multiple training modalities in patients with Alzheimer’s disease: a pilot study

    Directory of Open Access Journals (Sweden)

    Tai SY

    2016-11-01

    Full Text Available Shu-Yu Tai,1–4 Chia-Ling Hsu,5 Shu-Wan Huang,5 Tzu-Chiao Ma,6,7 Wen-Chien Hsieh,8,9 Yuan-Han Yang5,7,10,11 1Department of Family Medicine, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, 2Department of Family Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, 3Department of Family Medicine, School of Medicine, College of Medicine, Kaohsiung Medical University, 4Research Center for Environmental Medicine, Kaohsiung Medical University, 5Department of Neurology, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, 6Graduate Institute of Oral Health Sciences, Kaohsiung Medical University, 7Mentality Protection Center, Fo Guang Shan Compassion Foundation, 8Department of Social Work, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, 9Department of Sociology and Social Work, Kaohsiung Medical University, 10Department of Neurology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, 11Department of and Master’s Program in Neurology, Faculty of Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan Objective: This pilot study investigated the effects of multiple training modalities on cognition, neuropsychiatric symptoms, caregivers’ burden, and quality of life in patients with Alzheimer’s disease (AD.Patients and methods: This intervention study was conducted in 24 patients with AD aged ≥65 years with a Clinical Dementia Rating (CDR score of 0.5–1. The patients were assigned to receive multiple training modalities (1 hour for each training: Tai Chi, calligraphy, and drawing over a 6-week period in either the experimental group (n=14 or the comparison group (n=10. A series of neuropsychological tests – namely the Traditional Chinese version Mini-Mental Status Examination, Cognitive Assessment Screening Instrument (CASI, Neuropsychiatric Inventory and the Neuropsychiatric Inventory Caregiver Distress Scale, and the Clinical Dementia

  19. Retrieval practice with short-answer, multiple-choice, and hybrid tests.

    Science.gov (United States)

    Smith, Megan A; Karpicke, Jeffrey D

    2014-01-01

    Retrieval practice improves meaningful learning, and the most frequent way of implementing retrieval practice in classrooms is to have students answer questions. In four experiments (N=372) we investigated the effects of different question formats on learning. Students read educational texts and practised retrieval by answering short-answer, multiple-choice, or hybrid questions. In hybrid conditions students first attempted to recall answers in short-answer format, then identified answers in multiple-choice format. We measured learning 1 week later using a final assessment with two types of questions: those that could be answered by recalling information verbatim from the texts and those that required inferences. Practising retrieval in all format conditions enhanced retention, relative to a study-only control condition, on both verbatim and inference questions. However, there were little or no advantages of answering short-answer or hybrid format questions over multiple-choice questions in three experiments. In Experiment 4, when retrieval success was improved under initial short-answer conditions, there was an advantage of answering short-answer or hybrid questions over multiple-choice questions. The results challenge the simple conclusion that short-answer questions always produce the best learning, due to increased retrieval effort or difficulty, and demonstrate the importance of retrieval success for retrieval-based learning activities.

  20. Multiple Criteria and Multiple Periods Performance Analysis: The Comparison of North African Railways

    Science.gov (United States)

    Sabri, Karim; Colson, Gérard E.; Mbangala, Augustin M.

    2008-10-01

    Multi-period differences of technical and financial performances are analysed by comparing five North African railways over the period (1990-2004). A first approach is based on the Malmquist DEA TFP index for measuring the total factors productivity change, decomposed into technical efficiency change and technological changes. A multiple criteria analysis is also performed using the PROMETHEE II method and the software ARGOS. These methods provide complementary detailed information, especially by discriminating the technological and management progresses by Malmquist and the two dimensions of performance by Promethee: that are the service to the community and the enterprises performances, often in conflict.

  1. A generalized Grubbs-Beck test statistic for detecting multiple potentially influential low outliers in flood series

    Science.gov (United States)

    Cohn, T.A.; England, J.F.; Berenbrock, C.E.; Mason, R.R.; Stedinger, J.R.; Lamontagne, J.R.

    2013-01-01

    he Grubbs-Beck test is recommended by the federal guidelines for detection of low outliers in flood flow frequency computation in the United States. This paper presents a generalization of the Grubbs-Beck test for normal data (similar to the Rosner (1983) test; see also Spencer and McCuen (1996)) that can provide a consistent standard for identifying multiple potentially influential low flows. In cases where low outliers have been identified, they can be represented as “less-than” values, and a frequency distribution can be developed using censored-data statistical techniques, such as the Expected Moments Algorithm. This approach can improve the fit of the right-hand tail of a frequency distribution and provide protection from lack-of-fit due to unimportant but potentially influential low flows (PILFs) in a flood series, thus making the flood frequency analysis procedure more robust.

  2. On Thermally Interacting Multiple Boreholes with Variable Heating Strength: Comparison between Analytical and Numerical Approaches

    Directory of Open Access Journals (Sweden)

    Marc A. Rosen

    2012-08-01

    Full Text Available The temperature response in the soil surrounding multiple boreholes is evaluated analytically and numerically. The assumption of constant heat flux along the borehole wall is examined by coupling the problem to the heat transfer problem inside the borehole and presenting a model with variable heat flux along the borehole length. In the analytical approach, a line source of heat with a finite length is used to model the conduction of heat in the soil surrounding the boreholes. In the numerical method, a finite volume method in a three dimensional meshed domain is used. In order to determine the heat flux boundary condition, the analytical quasi-three-dimensional solution to the heat transfer problem of the U-tube configuration inside the borehole is used. This solution takes into account the variation in heating strength along the borehole length due to the temperature variation of the fluid running in the U-tube. Thus, critical depths at which thermal interaction occurs can be determined. Finally, in order to examine the validity of the numerical method, a comparison is made with the results of line source method.

  3. Compilation and comparison of test-hole location surveys in the vicinity of the Waste Isolation Pilot Plant site

    International Nuclear Information System (INIS)

    Gonzales, M.M.

    1989-02-01

    Between 1976 and 1988, many surveys were performed related to the Waste Isolation Pilot Plant and its geologic and hydrologic test holes, which are part of the hydrogeologic-characterization program. Among these surveys were two First-Order, Class I vertical surveys, a satellite survey, and a number of township-range surveys. An overview of the basic function, history, and methodology of each survey type is provided in this report along with a review and comparison of the two major test-hole surveys. Elevation and location data for 96 test holes and 4 shafts are also included. The comparison of the satellite survey to the township-range surveys showed that the latter have the following advantages: their data are more complete; their elevation data are more accurate; and their techniques can be used for surveying new wells, keeping the data set consistent. Therefore, the final township-range surveys were selected as the best source of elevation and location data to use in the WIPP hydrology program. 17 refs., 5 figs., 10 tabs

  4. Preliminary report of the comparison of multiple non-destructive assay techniques on LANL Plutonium Facility waste drums

    International Nuclear Information System (INIS)

    Bonner, C.; Schanfein, M.; Estep, R.

    1999-01-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content. The DOE Complex faces the daunting task of measuring nuclear material with both a wide range of masses and matrices. Similarly daunting can be the selection of a non-destructive assay (NDA) technique(s) to efficiently perform the quantitative assay over the entire waste population. In fulfilling its role of a DOE Defense Programs nuclear User Facility/Technology Development Center, the Los Alamos National Laboratory Plutonium Facility recently tested three commercially built and owned, mobile nondestructive assay (NDA) systems with special nuclear materials (SNM). Two independent commercial companies financed the testing of their three mobile NDA systems at the site. Contained within a single trailer is Canberra Industries segmented gamma scanner/waste assay system (SGS/WAS) and neutron waste drum assay system (WDAS). The third system is a BNFL Instruments Inc. (formerly known as Pajarito Scientific Corporation) differential die-away imaging passive/active neutron (IPAN) counter. In an effort to increase the value of this comparison, additional NDA techniques at LANL were also used to measure these same drums. These are comprised of three tomographic gamma scanners (one mobile unit and two stationary) and one developmental differential die-away system. Although not certified standards, the authors hope that such a comparison will provide valuable data for those considering these different NDA techniques to measure their waste as well as the developers of the techniques

  5. Defining and Developing "Critical Thinking" Through Devising and Testing Multiple Explanations of the Same Phenomenon

    Science.gov (United States)

    Etkina, Eugenia; Planinšič, Gorazd

    2015-10-01

    Most physics teachers would agree that one of the main reasons for her/his students to take physics is to learn to think critically. However, for years we have been assessing our students mostly on the knowledge of physics content (conceptually and quantitatively). Only recently have science educators started moving systematically towards achieving and assessing this critical thinking goal. In this paper we seek to show how guiding students to devise and test multiple explanations of observed phenomena can be used to improve their critical thinking.

  6. Proximal processes of children with profound multiple disabilities

    OpenAIRE

    Wilder, Jenny

    2008-01-01

    In this thesis four empirical studies dealt with children with profound multiple disabilities and their parents with regard to: (a) how parents perceived interaction with their children (b) how observed child/parent interaction was linked to behavior style of the children as perceived by the parents (c) how parents of children with profound multiple disabilities perceived child/parent interaction and behavior style of their children in comparison to parents to children without disabilities ma...

  7. A new bootstrap test for multiple assets joint risk testing

    NARCIS (Netherlands)

    Ardia, David; Gatarek, Lukasz; Hoogerheide, Lennart F.

    2017-01-01

    In this paper, a novel simulation-based methodology is proposed to test the validity of a set of marginal time series models, where the dependence structure between the time series is taken directly from the observed data. The procedure is useful when one wants to summarize the test results for

  8. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    Science.gov (United States)

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  9. Comparison test of electronic dosemeters

    International Nuclear Information System (INIS)

    Butterweck, G.; Zimmerli, H.P.; Wernli, C.

    2001-01-01

    To assist with a planned purchase of electronic dosemeters by the Swiss Federal Office for Civil Protection, the calibration laboratory of the Paul Scherrer Institute performed tests on 11 types of electronic dosemeters manufactured by 10 European and American companies. The technical specifications for the World Trade Organisation (WTO) tendering procedure were largely in accord with the specifications of the international standard IEC 61526. First tests were performed with samples from each type of dosemeter. The reproducibility of a dose of 0.1 mSv generated with 137 Cs radiation at a dose rate of 2.1 mSv.h -1 was found adequate for all tested dosemeter types. The response for environmental levels of radiation showed a large variation, indicating insufficient background correction of some dosemeters. A very high dose rate of 10 Sv.h -1 provoked faulty dose readings for more than half of the tested dosemeters. Dosemeter response for low-energy photon radiation was satisfactory for two of the tested dosemeter types. Four dosemeter types were selected for extended technical tests. Three samples of each of these dosemeter types were purchased. For drop and temperature tests the specifications of the WTO tendering procedure outranged the specification of the IEC standard. Whereas even at a temperature of -25 deg. C the tested dosemeters functioned normally, drops from a height of 2 m onto a wooden surface rendered the samples of two dosemeter types inoperative. (author)

  10. In vivo characterization of cortical and white matter neuroaxonal pathology in early multiple sclerosis.

    Science.gov (United States)

    Granberg, Tobias; Fan, Qiuyun; Treaba, Constantina Andrada; Ouellette, Russell; Herranz, Elena; Mangeat, Gabriel; Louapre, Céline; Cohen-Adad, Julien; Klawiter, Eric C; Sloane, Jacob A; Mainero, Caterina

    2017-11-01

    Neuroaxonal pathology is a main determinant of disease progression in multiple sclerosis; however, its underlying pathophysiological mechanisms, including its link to inflammatory demyelination and temporal occurrence in the disease course are still unknown. We used ultra-high field (7 T), ultra-high gradient strength diffusion and T1/T2-weighted myelin-sensitive magnetic resonance imaging to characterize microstructural changes in myelin and neuroaxonal integrity in the cortex and white matter in early stage multiple sclerosis, their distribution in lesional and normal-appearing tissue, and their correlations with neurological disability. Twenty-six early stage multiple sclerosis subjects (disease duration ≤5 years) and 24 age-matched healthy controls underwent 7 T T2*-weighted imaging for cortical lesion segmentation and 3 T T1/T2-weighted myelin-sensitive imaging and neurite orientation dispersion and density imaging for assessing microstructural myelin, axonal and dendrite integrity in lesional and normal-appearing tissue of the cortex and the white matter. Conventional mean diffusivity and fractional anisotropy metrics were also assessed for comparison. Cortical lesions were identified in 92% of early multiple sclerosis subjects and they were characterized by lower intracellular volume fraction (P = 0.015 by paired t-test), lower myelin-sensitive contrast (P = 0.030 by related-samples Wilcoxon signed-rank test) and higher mean diffusivity (P = 0.022 by related-samples Wilcoxon signed-rank test) relative to the contralateral normal-appearing cortex. Similar findings were observed in white matter lesions relative to normal-appearing white matter (all P test) and lower fractional anisotropy (P Wilcoxon signed-rank test) suggestive of less coherent underlying fibre orientation. Additionally, the normal-appearing white matter in multiple sclerosis subjects had diffusely lower intracellular volume fractions than the white matter in controls (P = 0.029 by unpaired

  11. Pool swell sub-scale testing and code comparison

    International Nuclear Information System (INIS)

    Elisson, K.

    1981-01-01

    The main objective of the experiment was to investigate the pool swell dynamics in general and the forces on the lowered central part of the diaphragm between drywell and wetwell in particular. Apart from the high speed camera pressure transducers and strain gauges were used to monitor the transient. Data was recorded on a 14 channel FM recorder and then digitalised and plotted. In total more than one hundred tests were performed including parametric variations of for example geometry, break flow, initial drywell pressure and initial water level. In parallel to this experiment pool swell calculations have been performed with the computer codes COPTA and STEALTH. COPTA which is a lumped mass code for pressure suppression containment analysis has a slug pool swell mode. STEALTH which is a general purpose lagrangian hydrodynamics code has been used in a 2-D axisymmetric version. The STEALTH code has been used to calculate the radial variations in the vertical displacement and velocity of the pool surface and to predict the load on the lowered central part of the diaphragm. A comparison between the calculations and the experimental data indicates that both codes are sufficiently correct in their description of the pool swell transient. (orig.)

  12. Effectiveness of Guided Multiple Choice Objective Questions Test on Students' Academic Achievement in Senior School Mathematics by School Location

    Science.gov (United States)

    Igbojinwaekwu, Patrick Chukwuemeka

    2015-01-01

    This study investigated, using pretest-posttest quasi-experimental research design, the effectiveness of guided multiple choice objective questions test on students' academic achievement in Senior School Mathematics, by school location, in Delta State Capital Territory, Nigeria. The sample comprised 640 Students from four coeducation secondary…

  13. Within-day variability on short and long walking tests in persons with multiple sclerosis.

    Science.gov (United States)

    Feys, Peter; Bibby, Bo; Romberg, Anders; Santoyo, Carme; Gebara, Benoit; de Noordhout, Benoit Maertens; Knuts, Kathy; Bethoux, Francois; Skjerbæk, Anders; Jensen, Ellen; Baert, Ilse; Vaney, Claude; de Groot, Vincent; Dalgas, Ulrik

    2014-03-15

    To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Observational study. MS rehabilitation and research centers in Europe and US within RIMS (European network for best practice and research in MS rehabilitation). Ambulatory persons with MS (Expanded Disability Status Scale 0-6.5). Subjects of different centers performed walking tests at 3 time points during a single day. 10MWT, 2MWT and 6MWT at fastest speed and 10MWT at usual speed. Ninety-five percent limits of agreement were computed using a random effects model with individual pwMS as random effect. Following this model, retest scores are with 95% certainty within these limits of baseline scores. In 102 subjects, within-day variability was constant in absolute units for the 10MWT, 2MWT and 6MWT at fastest speed (+/-0.26, 0.16 and 0.15m/s respectively, corresponding to +/-19.2m and +/-54 m for the 2MWT and 6MWT) independent on the severity of ambulatory dysfunction. This implies a greater relative variability with increasing disability level, often above 20% depending on the applied test. The relative within-day variability of the 10MWT at usual speed was +/-31% independent of ambulatory function. Absolute values of within-day variability on walking tests at fastest speed were independent of disability level and greater with short compared to long walking tests. Relative within-day variability remained overall constant when measured at usual speed. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  14. Estimates of statistical significance for comparison of individual positions in multiple sequence alignments

    Directory of Open Access Journals (Sweden)

    Sadreyev Ruslan I

    2004-08-01

    Full Text Available Abstract Background Profile-based analysis of multiple sequence alignments (MSA allows for accurate comparison of protein families. Here, we address the problems of detecting statistically confident dissimilarities between (1 MSA position and a set of predicted residue frequencies, and (2 between two MSA positions. These problems are important for (i evaluation and optimization of methods predicting residue occurrence at protein positions; (ii detection of potentially misaligned regions in automatically produced alignments and their further refinement; and (iii detection of sites that determine functional or structural specificity in two related families. Results For problems (1 and (2, we propose analytical estimates of P-value and apply them to the detection of significant positional dissimilarities in various experimental situations. (a We compare structure-based predictions of residue propensities at a protein position to the actual residue frequencies in the MSA of homologs. (b We evaluate our method by the ability to detect erroneous position matches produced by an automatic sequence aligner. (c We compare MSA positions that correspond to residues aligned by automatic structure aligners. (d We compare MSA positions that are aligned by high-quality manual superposition of structures. Detected dissimilarities reveal shortcomings of the automatic methods for residue frequency prediction and alignment construction. For the high-quality structural alignments, the dissimilarities suggest sites of potential functional or structural importance. Conclusion The proposed computational method is of significant potential value for the analysis of protein families.

  15. The utility of a 5(th) nap in multiple sleep latency test.

    Science.gov (United States)

    Muza, Rexford; Lykouras, Dimosthenis; Rees, Kate

    2016-02-01

    This is the first study that aimed to look specifically at the utility of the 5(th) nap in the multiple sleep latency test (MSLT), a test used to assist in the diagnosis of narcolepsy. Data was retrospectively collected from the Sleep Disorders Centre of a Tertiary Hospital on patients that had a 5(th) nap during their MSLT from the 08(th) November 2011 to 12(th) November 2014. Fifty-three patients had a 5(th) nap performed out of 378 MSLT studies. In 16% of cases a diagnosis of narcolepsy was given directly due to the inclusion of the 5(th) nap on the MSLT. Here a 5(th) nap allowed diagnostic criteria of mean sleep latency 2 SOREMPS to be met. In 53% of cases the mean sleep latency increased due to 5(th) nap inclusion; the mean sleep latency of the first four naps was 5.6 vs. 6.7 after inclusion of the 5(th) nap. The 5(th) nap is not often performed within the MSLT studies. Our study shows that only a few patients may benefit from a 5(th) nap opportunity which also led to increase of the mean sleep latency at the expense of extra time, cost, labour and increased patient anxiety.

  16. A default Bayesian hypothesis test for mediation.

    Science.gov (United States)

    Nuijten, Michèle B; Wetzels, Ruud; Matzke, Dora; Dolan, Conor V; Wagenmakers, Eric-Jan

    2015-03-01

    In order to quantify the relationship between multiple variables, researchers often carry out a mediation analysis. In such an analysis, a mediator (e.g., knowledge of a healthy diet) transmits the effect from an independent variable (e.g., classroom instruction on a healthy diet) to a dependent variable (e.g., consumption of fruits and vegetables). Almost all mediation analyses in psychology use frequentist estimation and hypothesis-testing techniques. A recent exception is Yuan and MacKinnon (Psychological Methods, 14, 301-322, 2009), who outlined a Bayesian parameter estimation procedure for mediation analysis. Here we complete the Bayesian alternative to frequentist mediation analysis by specifying a default Bayesian hypothesis test based on the Jeffreys-Zellner-Siow approach. We further extend this default Bayesian test by allowing a comparison to directional or one-sided alternatives, using Markov chain Monte Carlo techniques implemented in JAGS. All Bayesian tests are implemented in the R package BayesMed (Nuijten, Wetzels, Matzke, Dolan, & Wagenmakers, 2014).

  17. Comparing Effects of Biologic Agents in Treating Patients with Rheumatoid Arthritis: A Multiple Treatment Comparison Regression Analysis.

    Directory of Open Access Journals (Sweden)

    Ingunn Fride Tvete

    Full Text Available Rheumatoid arthritis patients have been treated with disease modifying anti-rheumatic drugs (DMARDs and the newer biologic drugs. We sought to compare and rank the biologics with respect to efficacy. We performed a literature search identifying 54 publications encompassing 9 biologics. We conducted a multiple treatment comparison regression analysis letting the number experiencing a 50% improvement on the ACR score be dependent upon dose level and disease duration for assessing the comparable relative effect between biologics and placebo or DMARD. The analysis embraced all treatment and comparator arms over all publications. Hence, all measured effects of any biologic agent contributed to the comparison of all biologic agents relative to each other either given alone or combined with DMARD. We found the drug effect to be dependent on dose level, but not on disease duration, and the impact of a high versus low dose level was the same for all drugs (higher doses indicated a higher frequency of ACR50 scores. The ranking of the drugs when given without DMARD was certolizumab (ranked highest, etanercept, tocilizumab/ abatacept and adalimumab. The ranking of the drugs when given with DMARD was certolizumab (ranked highest, tocilizumab, anakinra/rituximab, golimumab/ infliximab/ abatacept, adalimumab/ etanercept [corrected]. Still, all drugs were effective. All biologic agents were effective compared to placebo, with certolizumab the most effective and adalimumab (without DMARD treatment and adalimumab/ etanercept (combined with DMARD treatment the least effective. The drugs were in general more effective, except for etanercept, when given together with DMARDs.

  18. Dynamic Testing of Analogical Reasoning in 5- to 6-Year-Olds: Multiple-Choice versus Constructed-Response Training Items

    Science.gov (United States)

    Stevenson, Claire E.; Heiser, Willem J.; Resing, Wilma C. M.

    2016-01-01

    Multiple-choice (MC) analogy items are often used in cognitive assessment. However, in dynamic testing, where the aim is to provide insight into potential for learning and the learning process, constructed-response (CR) items may be of benefit. This study investigated whether training with CR or MC items leads to differences in the strategy…

  19. Comparison of multiple linear regression, partial least squares and artificial neural networks for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids.

    Science.gov (United States)

    Fragkaki, A G; Farmaki, E; Thomaidis, N; Tsantili-Kakoulidou, A; Angelis, Y S; Koupparis, M; Georgakopoulos, C

    2012-09-21

    The comparison among different modelling techniques, such as multiple linear regression, partial least squares and artificial neural networks, has been performed in order to construct and evaluate models for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids. The performance of the quantitative structure-retention relationship study, using the multiple linear regression and partial least squares techniques, has been previously conducted. In the present study, artificial neural networks models were constructed and used for the prediction of relative retention times of anabolic androgenic steroids, while their efficiency is compared with that of the models derived from the multiple linear regression and partial least squares techniques. For overall ranking of the models, a novel procedure [Trends Anal. Chem. 29 (2010) 101-109] based on sum of ranking differences was applied, which permits the best model to be selected. The suggested models are considered useful for the estimation of relative retention times of designer steroids for which no analytical data are available. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Coordinated voltage control for multiple wind plants in Eastern Wyoming. Analysis, field experience and validation

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Nicholas; MacDowell, Jason; Chmiel, Gary; Konopinski, Ryan; Gautam, Durga [GE Energy, Schenectady, NY (United States); Laughter, Grant; Hagen, Dave [PacifiCorp., Salt Lake City, UT (United States)

    2012-07-01

    At high levels of wind power penetration, multiple wind plants may be the predominant generation resource over large geographic areas. Thus, not only do wind plants need to provide a high level of functionality, they must coordinate properly with each other. This paper describes the analysis and field testing of wind plant voltage controllers designed to improve system voltage performance through passive coordination. The described wind power plant controls can coordinate the real and reactive power response of multiple wind turbines and thereby make the plant function as a single ''grid friendly'' power generation source. For this application, involving seven large wind plants with predominantly GE wind turbines in Eastern Wyoming, the voltage portion of the controllers were configured and tuned to allow the collective reactive power response of multiple wind plants in the region to work well together. This paper presents the results of the initial configuration and tuning study, and the results of the subsequent field tuning and testing of the modified controls. The paper also presents some comparisons of the measured field performance with the stability simulation models, which show that the available wind plant models provide accurate, high fidelity results for actual operating conditions of commercial wind power plants. (orig.)

  1. Injuries in martial arts: a comparison of five styles.

    Science.gov (United States)

    Zetaruk, M N; Violán, M A; Zurakowski, D; Micheli, L J

    2005-01-01

    To compare five martial arts with respect to injury outcomes. A one year retrospective cohort was studied using an injury survey. Data on 263 martial arts participants (Shotokan karate, n = 114; aikido, n = 47; tae kwon do, n = 49; kung fu, n = 39; tai chi, n = 14) were analysed. Predictor variables included age, sex, training frequency (3 h/week), experience (or=3 years), and martial art style. Outcome measures were injuries requiring time off from training, major injuries (>or=7 days off), multiple injuries (>or=3), body region, and type of injury. Logistic regression was used to determine odds ratios (OR) and confidence intervals (CI). Fisher's exact test was used for comparisons between styles, with a Bonferroni correction for multiple comparisons. The rate of injuries, expressed as percentage of participants sustaining an injury that required time off training a year, varied according to style: 59% tae kwon do, 51% aikido, 38% kung fu, 30% karate, and 14% tai chi. There was a threefold increased risk of injury and multiple injury in tae kwon do than karate (por=18 years of age were at greater risk of injury than younger ones (p3 h/week was also a significant predictor of injury (pkarate, the risks of head/neck injury, upper extremity injury, and soft tissue injury were all higher in aikido (pinjuries were higher in tae kwon do (pkarate. Different martial arts have significantly different types and distribution of injuries. Martial arts appear to be safe for young athletes, particularly those at beginner or intermediate levels.

  2. High prevalence of normal tests assessing hypercortisolism in subjects with mild and episodic Cushing's syndrome suggests that the paradigm for diagnosis and exclusion of Cushing's syndrome requires multiple testing.

    Science.gov (United States)

    Friedman, T C; Ghods, D E; Shahinian, H K; Zachery, L; Shayesteh, N; Seasholtz, S; Zuckerbraun, E; Lee, M L; McCutcheon, I E

    2010-11-01

    Many Endocrinologists believe that a single determination of eucortisolism or a single demonstration of appropriate suppression to dexamethasone excluded Cushing's syndrome, except in what was previously thought to be the rare patient with episodic or periodic Cushing's syndrome. We hypothesize that episodic Cushing's syndrome is relatively common and a single test assessing hypercortisolism may not be sufficient to accurately rule out or diagnose Cushing's syndrome and retrospectively examined the number of normal and abnormal tests assessing hypercortisolism performed on multiple occasions in 66 patients found to have mild and/or episodic Cushing's syndrome compared to a similar group of 54 patients evaluated for, but determined not to have Cushing's syndrome. We found that 65 of the 66 patients with Cushing's syndrome had at least one normal test of cortisol status and most patients had several normal tests. The probability of having Cushing's syndrome when one test was negative was 92% for 23:00 h salivary cortisol, 88% for 24-h UFC, 86% for 24-h 17OHS, and 54% for nighttime plasma cortisol. These results demonstrated that episodic hypercortisolism is highly prevalent in subjects with mild Cushing's syndrome and no single test was effective in conclusively diagnosing or excluding the condition. Rather, the paradigm for the diagnosis should be a careful history and physical examination and in those patients in whom mild Cushing's syndrome/disease is strongly suspected, multiple tests assessing hypercortisolism should be performed on subsequent occasions, especially when the patient is experiencing signs and symptoms of short-term hypercortisolism. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Comparison of Cerebral Glucose Metabolism between Possible and Probable Multiple System Atrophy

    Directory of Open Access Journals (Sweden)

    Kyum-Yil Kwon

    2009-05-01

    Full Text Available Background: To investigate the relationship between presenting clinical manifestations and imaging features of multisystem neuronal dysfunction in MSA patients, using 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET. Methods: We studied 50 consecutive MSA patients with characteristic brain MRI findings of MSA, including 34 patients with early MSA-parkinsonian (MSA-P and 16 with early MSA-cerebellar (MSA-C. The cerebral glucose metabolism of all MSA patients was evaluated in comparison with 25 age-matched controls. 18F-FDG PET results were assessed by the Statistic Parametric Mapping (SPM analysis and the regions of interest (ROI method. Results: The mean time from disease onset to 18F-FDG PET was 25.9±13.0 months in 34 MSA-P patients and 20.1±11.1 months in 16 MSA-C patients. Glucose metabolism of the putamen showed a greater decrease in possible MSA-P than in probable MSA-P (p=0.031. Although the Unified Multiple System Atrophy Rating Scale (UMSARS score did not differ between possible MSA-P and probable MSA-P, the subscores of rigidity (p=0.04 and bradykinesia (p= 0.008 were significantly higher in possible MSA-P than in probable MSA-P. Possible MSA-C showed a greater decrease in glucose metabolism of the cerebellum than probable MSA-C (p=0.016. Conclusions: Our results may suggest that the early neuropathological pattern of possible MSA with a predilection for the striatonigral or olivopontocerebellar system differs from that of probable MSA, which has prominent involvement of the autonomic nervous system in addition to the striatonigral or olivopontocerebellar system.

  4. Effect of response format on cognitive reflection: Validating a two- and four-option multiple choice question version of the Cognitive Reflection Test.

    Science.gov (United States)

    Sirota, Miroslav; Juanchich, Marie

    2018-03-27

    The Cognitive Reflection Test, measuring intuition inhibition and cognitive reflection, has become extremely popular because it reliably predicts reasoning performance, decision-making, and beliefs. Across studies, the response format of CRT items sometimes differs, based on the assumed construct equivalence of tests with open-ended versus multiple-choice items (the equivalence hypothesis). Evidence and theoretical reasons, however, suggest that the cognitive processes measured by these response formats and their associated performances might differ (the nonequivalence hypothesis). We tested the two hypotheses experimentally by assessing the performance in tests with different response formats and by comparing their predictive and construct validity. In a between-subjects experiment (n = 452), participants answered stem-equivalent CRT items in an open-ended, a two-option, or a four-option response format and then completed tasks on belief bias, denominator neglect, and paranormal beliefs (benchmark indicators of predictive validity), as well as on actively open-minded thinking and numeracy (benchmark indicators of construct validity). We found no significant differences between the three response formats in the numbers of correct responses, the numbers of intuitive responses (with the exception of the two-option version, which had a higher number than the other tests), and the correlational patterns of the indicators of predictive and construct validity. All three test versions were similarly reliable, but the multiple-choice formats were completed more quickly. We speculate that the specific nature of the CRT items helps build construct equivalence among the different response formats. We recommend using the validated multiple-choice version of the CRT presented here, particularly the four-option CRT, for practical and methodological reasons. Supplementary materials and data are available at https://osf.io/mzhyc/ .

  5. A novel PMT test system based on waveform sampling

    Science.gov (United States)

    Yin, S.; Ma, L.; Ning, Z.; Qian, S.; Wang, Y.; Jiang, X.; Wang, Z.; Yu, B.; Gao, F.; Zhu, Y.; Wang, Z.

    2018-01-01

    Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8"R5912 and the 20"R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of charge, amplitude, signal width and rising time are analyzed offline. The results from Charge-to-Digital Converter, Time-to-Digital Converter and waveform sampling are discussed in detailed comparison.

  6. Student certainty answering misconception question: study of Three-Tier Multiple-Choice Diagnostic Test in Acid-Base and Solubility Equilibrium

    Science.gov (United States)

    Ardiansah; Masykuri, M.; Rahardjo, S. B.

    2018-04-01

    Students’ concept comprehension in three-tier multiple-choice diagnostic test related to student confidence level. The confidence level related to certainty and student’s self-efficacy. The purpose of this research was to find out students’ certainty in misconception test. This research was quantitative-qualitative research method counting students’ confidence level. The research participants were 484 students that were studying acid-base and equilibrium solubility subject. Data was collected using three-tier multiple-choice (3TMC) with thirty questions and students’ questionnaire. The findings showed that #6 item gives the highest misconception percentage and high student confidence about the counting of ultra-dilute solution’s pH. Other findings were that 1) the student tendency chosen the misconception answer is to increase over item number, 2) student certainty decreased in terms of answering the 3TMC, and 3) student self-efficacy and achievement were related each other in the research. The findings suggest some implications and limitations for further research.

  7. Comparison of EPRI safety valve test data with analytically determined hydraulic results

    International Nuclear Information System (INIS)

    Smith, L.C.; Howe, K.S.

    1983-01-01

    NUREG-0737 (November 1980) and all subsequent U.S. NRC generic follow-up letters require that all operating plant licensees and applicants verify the acceptability of plant specific pressurizer safety valve piping systems for valve operation transients by testing. To aid in this verification process, the Electric Power Research Institute (EPRI) conducted an extensive testing program at the Combustion Engineering Test Facility. Pertinent tests simulating dynamic opening of the safety valves for representative upstream environments were carried out. Different models and sizes of safety valves were tested at the simulated operating conditions. Transducers placed at key points in the system monitored a variety of thermal, hydraulic and structural parameters. From this data, a more complete description of the transient can be made. The EPRI test configuration was analytically modeled using a one-dimensional thermal hydraulic computer program that uses the method of characteristics approach to generate key fluid parameters as a function of space and time. The conservative equations are solved by applying both the implicit and explicit characteristic methods. Unbalanced or wave forces were determined for each straight run of pipe bounded on each side by a turn or elbow. Blowdown forces were included, where appropriate. Several parameters were varied to determine the effects on the pressure, hydraulic forces and timings of events. By comparing these quantities with the experimentally obtained data, an approximate picture of the flow dynamics is arrived at. Two cases in particular are presented. These are the hot and cold loop seal discharge tests made with the Crosby 6M6 spring-loaded safety valve. Included in the paper is a description of the hydraulic code, modeling techniques and assumptions, a comparison of the numerical results with experimental data and a qualitative description of the factors which govern pipe support loading. (orig.)

  8. The Comparison Study of Contralateral Transient Evoked Otoacoustic Emission (TEOAE Suppression in Normal Hearing Subjects and Multiple Sclerosis Patients

    Directory of Open Access Journals (Sweden)

    KH Mohamadkhani

    2007-01-01

    Full Text Available ABSTRACT: Introduction & Objective: A common auditory complaint of multiple sclerosis patients, is misunderstanding speech in the presence of background noise. Evidence from animal and human studies has suggested that the medial olivocochlear bundle may play an important role in hearing noise. The medial olivocochlear bundle function can be evaluated by the suppression effect of transient otoacoustic emission in response to contralateral acoustic stimulation. The present study was conducted to investigate the suppression effect of transient otoacoustic emission in multiple sclerosis patients. Materials & Methods: This analytical case-control study was conducted on 34 multiple sclerosis patients (24 female, 10 male, aged 20-50 years and 34 controls matched for age and gender in Faculty of Rehabilitation, Tehran University of Medical Sciences in 2006. All cases were selected in simple random manner. The suppression effect of transient otoacoustic emission was evaluated by comparing the transient otoacoustic emission levels with and without contralateral acoustic stimulation. Data were analyzed using SPSS software and independent T- test. Results:There was no significant difference in transient otoacoustic emission levels of two groups, but a significantly reduced suppression effect of transient otoacoustic emission was found in multiple sclerosis patients, in compare with the controls. Conclusion: Outer hair cells activity in multiple sclerosis patients was normal but these patients presented low activity of the medial olivocochlear bundle system which could affect their ability to hear in the presence of background noise.

  9. Neutralizer Hollow Cathode Simulations and Comparisons with Ground Test Data

    Science.gov (United States)

    Mikellides, Ioannis G.; Snyder, John S.; Goebel, Dan M.; Katz, Ira; Herman, Daniel A.

    2009-01-01

    The fidelity of electric propulsion physics-based models depends largely on the validity of their predictions over a range of operating conditions and geometries. In general, increased complexity of the physics requires more extensive comparisons with laboratory data to identify the region(s) that lie outside the validity of the model assumptions and to quantify the uncertainties within its range of application. This paper presents numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes. The simulations were performed using a two-dimensional axisymmetric model that solves numerically a relatively extensive system of conservation laws for the partially ionized gas in these devices. A summary of the comparisons between simulation results and Langmuir probe measurements is provided. The model has also been employed to provide insight into recent ground test observations of the neutralizer cathode in NEXT. It is found that a likely cause of the observed keeper voltage drop is cathode orifice erosion. However, due to the small magnitude of this change, is approx. 0.5 V (less than 5% of the beginning-of-life value) over 10 khrs, and in light of the large uncertainties of the cathode material sputtering yield at low ion energies, other causes cannot be excluded. Preliminary simulations to understand transition to plume mode suggest that in the range of 3-5 sccm the existing 2-D model reproduces fairly well the rise of the keeper voltage in the NEXT neutralizer as observed in the laboratory. At lower flow rates the simulation produces oscillations in the keeper current and voltage that require prohibitively small time-steps to resolve with the existing algorithms.

  10. Evaluation of taper joints with combined fatigue and crevice corrosion testing: Comparison to human explanted modular prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Reclaru, L., E-mail: lucien.reclaru@pxgroup.com [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Brooks, R.A. [Orthopaedic Research, Addenbrooke' s Hospital, University of Cambridge, Box 180 Hills Road, CB2 0QQ Cambridge (United Kingdom); Zuberbühler, M. [Smith and Nephew Orthopaedics AG, Schachenalle 29, 5001 Aarau (Switzerland); Eschler, P.-Y.; Constantin, F. [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Tomoaia, G. [University of Medicine and Pharmacy Iuliu Hateganu of Cluj-Napoca, Dept. of Orthopaedics and Traumatology, Cluj-Napoca (Romania)

    2014-01-01

    The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses. - Highlights: • Electrochemical crevice corrosion testing combined with fatigue test conducted on Ti6Al7Nb and Ti6Al4V modular prostheses • Cations released from integral prostheses • Comparison of human explanted modular prostheses with the similar prostheses evaluated in cyclic dynamic crevice corrosion.

  11. Comparison of the long-time corrosion behavior of certain Zr alloys in PWR, BWR, and laboratory tests

    International Nuclear Information System (INIS)

    Garzarolli, F.; Broy, Y.; Busch, R.A.

    1996-01-01

    Laboratory corrosion tests have always been an important tool for Zr alloy development and optimization. However, it must be known whether a test is representative for the application in-reactor. To shed more light on this question, coupons of several Zr alloys were exposed under isothermal conditions in BWR and PWR type environments. For evaluation of the in-PWR tests and for comparison of out-of-pile and in-pile tests, the different temperatures and times were normalized to a temperature-independent normalized time by assuming an activation temperature (Q/R) of 14,200 K. Comparison of in-PWR and out-of-pile corrosion behavior of Zircaloy shows that corrosion deviates to higher values in PWR if a weight gain of about 50 mg/dm 2 is exceeded. In the case of the Zr2.5Nb alloy, a slight deviation of corrosion as compared to laboratory results starts in PWR only above a weight gain of 100 mg/dm 2 . In BWR, corrosion of Zircaloy is enhanced early in time if compared with out-of-pile. Zr2.5Nb exhibits higher corrosion results in BWR than Zircaloy-4. Alloying chemistry and material condition affect corrosion of Zr alloys. However, several of the material parameters have shown a different ranking in the different environments. Nevertheless, several material parameters influencing in-reactor corrosion like the second phase particle (SPP) size of in-PWR behavior as the Sn and Fe content can be optimized by out-of-pile corrosion tests

  12. Validity of the Symbol Digit Modalities Test as a cognition performance outcome measure for multiple sclerosis.

    Science.gov (United States)

    Benedict, Ralph Hb; DeLuca, John; Phillips, Glenn; LaRocca, Nicholas; Hudson, Lynn D; Rudick, Richard

    2017-04-01

    Cognitive and motor performance measures are commonly employed in multiple sclerosis (MS) research, particularly when the purpose is to determine the efficacy of treatment. The increasing focus of new therapies on slowing progression or reversing neurological disability makes the utilization of sensitive, reproducible, and valid measures essential. Processing speed is a basic elemental cognitive function that likely influences downstream processes such as memory. The Multiple Sclerosis Outcome Assessments Consortium (MSOAC) includes representatives from advocacy organizations, Food and Drug Administration (FDA), European Medicines Agency (EMA), National Institute of Neurological Disorders and Stroke (NINDS), academic institutions, and industry partners along with persons living with MS. Among the MSOAC goals is acceptance and qualification by regulators of performance outcomes that are highly reliable and valid, practical, cost-effective, and meaningful to persons with MS. A critical step for these neuroperformance metrics is elucidation of clinically relevant benchmarks, well-defined degrees of disability, and gradients of change that are deemed clinically meaningful. This topical review provides an overview of research on one particular cognitive measure, the Symbol Digit Modalities Test (SDMT), recognized as being particularly sensitive to slowed processing of information that is commonly seen in MS. The research in MS clearly supports the reliability and validity of this test and recently has supported a responder definition of SDMT change approximating 4 points or 10% in magnitude.

  13. p-hacking by post hoc selection with multiple opportunities: Detectability by skewness test?: Comment on Simonsohn, Nelson, and Simmons (2014).

    Science.gov (United States)

    Ulrich, Rolf; Miller, Jeff

    2015-12-01

    Simonsohn, Nelson, and Simmons (2014) have suggested a novel test to detect p-hacking in research, that is, when researchers report excessive rates of "significant effects" that are truly false positives. Although this test is very useful for identifying true effects in some cases, it fails to identify false positives in several situations when researchers conduct multiple statistical tests (e.g., reporting the most significant result). In these cases, p-curves are right-skewed, thereby mimicking the existence of real effects even if no effect is actually present. (c) 2015 APA, all rights reserved).

  14. Investigation of the Validity and Reliability of Balance Evaluation Systems Test (BESTest in Assessment of Balance Disorders in People With Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Samira Kamalian Lari

    2018-01-01

    Conclusion  After changing and removing part of question 6 of the second domain, results demonstrated that the questionnaire BESTest is a valid and reliable test for assessing balance performance in multiple sclerosis patients. It can be used as an accurate tool, both in the areas of clinical (to evaluate the patients’ equilibrium status and purposeful therapy planning and to apply for scientific research in patients with multiple sclerosis.

  15. Comparison of Brucella immunoglobulin M and G flow assays with serum agglutination and 2-mercaptoethanol tests in the diagnosis of brucellosis

    NARCIS (Netherlands)

    Zeytinoğlu, Ayşin; Turhan, Ajda; Altuğlu, Imre; Bilgiç, Altinay; Abdoel, Theresia H.; Smits, Henk L.

    2006-01-01

    The diagnostic value of Brucella IgM/IgG flow assays was evaluated in comparison with serum agglutination and 2-mercaptoethanol tests by testing a selection of serum samples submitted to the laboratory because of clinical suspicion of brucellosis. All 39 admission and 11 follow-up samples that

  16. [Continuing medical education: how to write multiple choice questions].

    Science.gov (United States)

    Soler Fernández, R; Méndez Díaz, C; Rodríguez García, E

    2013-06-01

    Evaluating professional competence in medicine is a difficult but indispensable task because it makes it possible to evaluate, at different times and from different perspectives, the extent to which the knowledge, skills, and values required for exercising the profession have been acquired. Tests based on multiple choice questions have been and continue to be among the most useful tools for objectively evaluating learning in medicine. When these tests are well designed and correctly used, they can stimulate learning and even measure higher cognitive skills. Designing a multiple choice test is a difficult task that requires knowledge of the material to be tested and of the methodology of test preparation as well as time to prepare the test. The aim of this article is to review what can be evaluated through multiple choice tests, the rules and guidelines that should be taken into account when writing multiple choice questions, the different formats that can be used, the most common errors in elaborating multiple choice tests, and how to analyze the results of the test to verify its quality. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  17. Maltreatment in multiple-birth children.

    Science.gov (United States)

    Lang, Cathleen A; Cox, Matthew J; Flores, Glenn

    2013-12-01

    The rate of multiple births has increased over the last two decades. In 1982, an increased frequency of injuries among this patient population was noted, but few studies have evaluated the increased incidence of maltreatment in twins. The study aim was to evaluate the features of all multiple-birth children with substantiated physical abuse and/or neglect over a four-year period at a major children's hospital. A Retrospective chart review was conducted of multiple-gestation children in which at least one child in the multiple set experienced child maltreatment from January 2006 to December 2009. Data regarding the child, injuries, family, and perpetrators were abstracted. We evaluated whether family and child characteristics were associated with maltreatment, and whether types of injuries were similar within multiple sets. For comparison, data from the same time period for single-birth maltreated children also were abstracted, including child age, gestational age at birth, and injury type. There were 19 sets of multiple births in which at least one child had abusive injuries and/or neglect. In 10 of 19 sets (53%), all multiples were found to have a form of maltreatment, and all children in these multiple sets shared at least one injury type. Parents lived together in 63% of cases. Fathers and mothers were the alleged perpetrator in 42% of the cases. Multiple-gestation-birth maltreated children were significantly more likely than single-birth maltreated children to have abdominal trauma (13% vs. 1%, respectively; pchildren often, but not always, were abused. In sets with two maltreated children, children usually shared the same modes of maltreatment. Multiples are significantly more likely than singletons to be younger and experience fractures and abdominal trauma. The findings support the current standard practice of evaluating all children in a multiple set when one is found to be abused or neglected. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Evaluation of the Trail Making Test and interval timing as measures of cognition in healthy adults: comparisons by age, education, and gender.

    Science.gov (United States)

    Płotek, Włodzimierz; Łyskawa, Wojciech; Kluzik, Anna; Grześkowiak, Małgorzata; Podlewski, Roland; Żaba, Zbigniew; Drobnik, Leon

    2014-02-03

    Human cognitive functioning can be assessed using different methods of testing. Age, level of education, and gender may influence the results of cognitive tests. The well-known Trail Making Test (TMT), which is often used to measure the frontal lobe function, and the experimental test of Interval Timing (IT) were compared. The methods used in IT included reproduction of auditory and visual stimuli, with the subsequent production of the time intervals of 1-, 2-, 5-, and 7-seconds durations with no pattern. Subjects included 64 healthy adult volunteers aged 18-63 (33 women, 31 men). Comparisons were made based on age, education, and gender. TMT was performed quickly and was influenced by age, education, and gender. All reproduced visual and produced intervals were shortened and the reproduction of auditory stimuli was more complex. Age, education, and gender have more pronounced impact on the cognitive test than on the interval timing test. The reproduction of the short auditory stimuli was more accurate in comparison to other modalities used in the IT test. The interval timing, when compared to the TMT, offers an interesting possibility of testing. Further studies are necessary to confirm the initial observation.

  20. Eye and hand motor interactions with the Symbol Digit Modalities Test in early multiple sclerosis.

    Science.gov (United States)

    Nygaard, Gro O; de Rodez Benavent, Sigrid A; Harbo, Hanne F; Laeng, Bruno; Sowa, Piotr; Damangir, Soheil; Bernhard Nilsen, Kristian; Etholm, Lars; Tønnesen, Siren; Kerty, Emilia; Drolsum, Liv; Inge Landrø, Nils; Celius, Elisabeth G

    2015-11-01

    Eye and hand motor dysfunction may be present early in the disease course of relapsing-remitting multiple sclerosis (RRMS), and can affect the results on visual and written cognitive tests. We aimed to test for differences in saccadic initiation time (SI time) between RRMS patients and healthy controls, and whether SI time and hand motor speed interacted with the written version of the Symbol Digit Modalities Test (wSDMT). Patients with RRMS (N = 44, age 35.1 ± 7.3 years), time since diagnosis < 3 years and matched controls (N = 41, age 33.2 ± 6.8 years) were examined with ophthalmological, neurological and neuropsychological tests, as well as structural MRI (white matter lesion load (WMLL) and brainstem lesions), visual evoked potentials (VEP) and eye-tracker examinations of saccades. SI time was longer in RRMS than controls (p < 0.05). SI time was not related to the Paced Auditory Serial Addition Test (PASAT), WMLL or to the presence of brainstem lesions. 9 hole peg test (9HP) correlated significantly with WMLL (r = 0.58, p < 0.01). Both SI time and 9HP correlated negatively with the results of wSDMT (r = -0.32, p < 0.05, r = -0.47, p < 0.01), but none correlated with the results of PASAT. RRMS patients have an increased SI time compared to controls. Cognitive tests results, exemplified by the wSDMT, may be confounded by eye and hand motor function. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Analysis of oil-pipeline distribution of multiple products subject to delivery time-windows

    Science.gov (United States)

    Jittamai, Phongchai

    This dissertation defines the operational problems of, and develops solution methodologies for, a distribution of multiple products into oil pipeline subject to delivery time-windows constraints. A multiple-product oil pipeline is a pipeline system composing of pipes, pumps, valves and storage facilities used to transport different types of liquids. Typically, products delivered by pipelines are petroleum of different grades moving either from production facilities to refineries or from refineries to distributors. Time-windows, which are generally used in logistics and scheduling areas, are incorporated in this study. The distribution of multiple products into oil pipeline subject to delivery time-windows is modeled as multicommodity network flow structure and mathematically formulated. The main focus of this dissertation is the investigation of operating issues and problem complexity of single-source pipeline problems and also providing solution methodology to compute input schedule that yields minimum total time violation from due delivery time-windows. The problem is proved to be NP-complete. The heuristic approach, a reversed-flow algorithm, is developed based on pipeline flow reversibility to compute input schedule for the pipeline problem. This algorithm is implemented in no longer than O(T·E) time. This dissertation also extends the study to examine some operating attributes and problem complexity of multiple-source pipelines. The multiple-source pipeline problem is also NP-complete. A heuristic algorithm modified from the one used in single-source pipeline problems is introduced. This algorithm can also be implemented in no longer than O(T·E) time. Computational results are presented for both methodologies on randomly generated problem sets. The computational experience indicates that reversed-flow algorithms provide good solutions in comparison with the optimal solutions. Only 25% of the problems tested were more than 30% greater than optimal values and

  2. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    Science.gov (United States)

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  3. Report on the environmental and sanitary impacts of the nuclear tests performed by France between 1960 and 1996 and elements of comparison with the tests performed by the other nuclear Powers

    International Nuclear Information System (INIS)

    Bataille, Ch.; Revol, H.

    2002-01-01

    This report makes a comprehensive presentation of the French atmospheric and underground nuclear tests performed in Sahara and Polynesia between 1960 and 1996 with their possible impact on the health of populations and personnel and on the environment. A comparison is made with similar tests performed by other nuclear Powers: US (Marshall islands, Nevada), former Soviet union (Semipalatinsk, Novaya Zemlya), UK (several atmospheric test-sites), China, India, Pakistan. (J.S.)

  4. Comparison between immediate and delayed imaging after gadolinium chelate injection for detecting enhanced lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Alizadeh, A.; Roudbari, A.; Heidarzadeh, A.; Kouhsari, M.

    2010-01-01

    Magnetic resonance imaging is a noninvasive and valuable method in the diagnosis of Multiple Sclerosis. Compared with other modalities, the sensitivity of Magnetic resonance imaging for detection of the lesion increases using magnetization transfer and delayed imaging. Our aim was to compare the two methods in detecting Multiple Sclerosis lesions. Patients and Methods: In this double-blind clinical trial, twenty-one patients with the definite diagnosis of Multiple Sclerosis referred to Poursina Hospital, Rasht were included. Two radiologists evaluated all the images. First, images without contrast were conducted, then 0.1 mmol/kg contrast material (Dotarem, single dose) was injected and after 30 minutes, T1W and magnetization transfer images were obtained. Seventy-two hours later, T1W images were obtained immediately after injection of 0.2 mmol/kg contrast material (double dose). The data were analyzed using Fisher's and McNemar tests by SPSS for Windows. Results: Delayed magnetization transfer showed 44 enhanced lesions using magnetization transfer (69.84%) and 29 lesions using T1 (46.03%). In addition, the number of enhanced lesions in the delayed method were significantly more than those in the immediate method (p value=0.003). Conclusion: The use of single dose in combination with magnetization transfer and delayed images after 20-30 minutes enables us to detect more enhanced lesions.

  5. Shaking table testing of a HTGR reactor core, comparison with the results obtained using a nonlinear mathematical model

    International Nuclear Information System (INIS)

    Berriaud, C.; Cebe, E.; Livolant, M.; Buland, P.

    1975-01-01

    Two series of horizontal tests have been performed at Saclay on the shaking table VESUVE: sinusoidal test and time history response. Sinusoidal tests have shown the strongly nonlinear dynamic behavior of the core. The resonant frequency of the core is dependent on the level of the excitation. These phenomena have been explained by a computer code, which is a lumped mass nonlinear model. El Centro time history displacement at the level of PCRV was reproduced on the shaking table. The analytical model was applied to this excitation and good comparison was obtained for forces and velocities [fr

  6. Preschool Multiple-Breath Washout Testing. An Official American Thoracic Society Technical Statement.

    Science.gov (United States)

    Robinson, Paul D; Latzin, Philipp; Ramsey, Kathryn A; Stanojevic, Sanja; Aurora, Paul; Davis, Stephanie D; Gappa, Monika; Hall, Graham L; Horsley, Alex; Jensen, Renee; Lum, Sooky; Milla, Carlos; Nielsen, Kim G; Pittman, Jessica E; Rosenfeld, Margaret; Singer, Florian; Subbarao, Padmaja; Gustafsson, Per M; Ratjen, Felix

    2018-03-01

    Obstructive airway disease is nonuniformly distributed throughout the bronchial tree, although the extent to which this occurs can vary among conditions. The multiple-breath washout (MBW) test offers important insights into pediatric lung disease, not available through spirometry or resistance measurements. The European Respiratory Society/American Thoracic Society inert gas washout consensus statement led to the emergence of validated commercial equipment for the age group 6 years and above; specific recommendations for preschool children were beyond the scope of the document. Subsequently, the focus has shifted to MBW applications within preschool subjects (aged 2-6 yr), where a "window of opportunity" exists for early diagnosis of obstructive lung disease and intervention. This preschool-specific technical standards document was developed by an international group of experts, with expertise in both custom-built and commercial MBW equipment. A comprehensive review of published evidence was performed. Recommendations were devised across areas that place specific age-related demands on MBW systems. Citing evidence where available in the literature, recommendations are made regarding procedures that should be used to achieve robust MBW results in the preschool age range. The present work also highlights the important unanswered questions that need to be addressed in future work. Consensus recommendations are outlined to direct interested groups of manufacturers, researchers, and clinicians in preschool device design, test performance, and data analysis for the MBW technique.

  7. Comparison of Numerical Analyses with a Static Load Test of a Continuous Flight Auger Pile

    Science.gov (United States)

    Hoľko, Michal; Stacho, Jakub

    2014-12-01

    The article deals with numerical analyses of a Continuous Flight Auger (CFA) pile. The analyses include a comparison of calculated and measured load-settlement curves as well as a comparison of the load distribution over a pile's length. The numerical analyses were executed using two types of software, i.e., Ansys and Plaxis, which are based on FEM calculations. Both types of software are different from each other in the way they create numerical models, model the interface between the pile and soil, and use constitutive material models. The analyses have been prepared in the form of a parametric study, where the method of modelling the interface and the material models of the soil are compared and analysed. Our analyses show that both types of software permit the modelling of pile foundations. The Plaxis software uses advanced material models as well as the modelling of the impact of groundwater or overconsolidation. The load-settlement curve calculated using Plaxis is equal to the results of a static load test with a more than 95 % degree of accuracy. In comparison, the load-settlement curve calculated using Ansys allows for the obtaining of only an approximate estimate, but the software allows for the common modelling of large structure systems together with a foundation system.

  8. Comparison of LIFE-4 and TEMECH code predictions with TREAT transient test data

    International Nuclear Information System (INIS)

    Gneiting, B.C.; Bard, F.E.; Hunter, C.W.

    1984-09-01

    Transient tests in the TREAT reactor were performed on FFTF Reference design mixed-oxide fuel pins, most of which had received prior steady-state irradiation in the EBR-II reactor. These transient test results provide a data base for calibration and verification of fuel performance codes and for evaluation of processes that affect pin damage during transient events. This paper presents a comparison of the LIFE-4 and TEMECH fuel pin thermal/mechanical analysis codes with the results from 20 HEDL TREAT experiments, ten of which resulted in pin failure. Both the LIFE-4 and TEMECH codes provided an adequate representation of the thermal and mechanical data from the TREAT experiments. Also, a criterion for 50% probability of pin failure was developed for each code using an average cumulative damage fraction value calculated for the pins that failed. Both codes employ the two major cladding loading mechanisms of differential thermal expansion and central cavity pressurization which were demonstrated by the test results. However, a detailed evaluation of the code predictions shows that the two code systems weigh the loading mechanism differently to reach the same end points of the TREAT transient results

  9. The impact of comorbidity on mortality in multiple myeloma

    DEFF Research Database (Denmark)

    Gregersen, Henrik; Vangsted, Annette Juul; Abildgaard, Niels

    2017-01-01

    To describe the prevalence of comorbidity and its impact on survival in newly diagnosed multiple myeloma patients compared with population controls. Cases of newly diagnosed symptomatic multiple myeloma during the 2005-2012 period were identified in the Danish National Multiple Myeloma Registry....... For each myeloma patient, 10 members of the general population matched by age and sex were chosen from the national Civil Registration System. Data on comorbidity in the myeloma patients and the general population comparison cohort were collected by linkage to the Danish National Patient Registry (DNPR......). Cox proportional hazards regression models were used to evaluate the prognostic significance of comorbidity. The study included 2190 cases of multiple myeloma and 21,900 population controls. The comorbidity was increased in multiple myeloma patients compared with population controls, odds ratio (OR) 1...

  10. Analytical quality control of neutron activation analysis by interlaboratory comparison and proficiency test

    International Nuclear Information System (INIS)

    Kim, S. H.; Moon, J. H.; Jeong, Y. S.

    2002-01-01

    Two air filters (V-50, P-50) artificially loaded with urban dust were provided from IAEA and trace elements to study inter-laboratory comparison and proficiency test were determined using instrumental neutron activation analysis non-destructively. Standard reference material(Urban Particulate Matter, NIST SRM 1648) of National Institute of Standard and Technology was used for internal analytical quality control. About 20 elements in each loaded filter sample were determined, respectively. Our analytical data were compared with statistical results using neutron activation analysis, particle induced X-ray emission spectrometry, inductively coupled plasma mass spectroscopy, etc., which were collected from 49 laboratories of 40 countries. From the results that were statistically re-treated with reported values, Z-scores of our analytical values are within ±2. In addition, the results of proficiency test are passed and accuracy and precision of the analytical values are reliable. Consequently, it was proved that analytical quality control for the analysis of air dust samples is reasonable

  11. Correlation between olfactory dysfunction and various clinical parameters in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Kostić Jelena

    2009-01-01

    Full Text Available Background/Aim. Multiple sclerosis (MS is a chronic inflammatory disease of the central nervous system (CNS characterized by myelin destruction and axon loss. Among various clinical manifestations of MS cognitive disorders are frequent. Olfactory disorders are also noticed but they are rarely considered in clinical practice. The aim of the present study was to examine frequency of olfactory dysfunction in patients with MS and its relationship to clinical parameters. Methods. Our study comprised 61 consecutive patients with definite MS who were hospitalized at the Department for Multiple Sclerosis and Other Immune- Mediated Disorders of CNS, Institute of Neurology, Clinical Center of Serbia, Belgrade, and 45 gender-, age- and education-matched healthy voluntaries. The Pocket Smell Test (PST was used for examination of olfactory function. Cognitive functions were analyzed using the tests from the Brief Battery of Neuropsychological Tests: Paced Auditory Serial Addition Test 3-minute Version (PASAT 3', Word List Generation (WLG and Symbol Digit Modalities Test (SDMT. Results. Olfactory dysfunction was found in 26 (43% MS patients and 5 (11% controls (p = 0.001. Statistically significant positive correlation was found only between PST score and WLG scores (r = 0.297, p = 0.030. In comparison with the previously published normative values, our subjects with MS had decrease in the mean indices of the PASAT 3' in 28%, SDMT in 51% and WLG in 90% of the subjects. Conclusion. Olfactory dysfunction is frequent in our population of patients with MS. This disturbance correlates with the impairment of cognitive functions in these patients.

  12. Comparison of lists of genes based on functional profiles

    Directory of Open Access Journals (Sweden)

    Salicrú Miquel

    2011-10-01

    Full Text Available Abstract Background How to compare studies on the basis of their biological significance is a problem of central importance in high-throughput genomics. Many methods for performing such comparisons are based on the information in databases of functional annotation, such as those that form the Gene Ontology (GO. Typically, they consist of analyzing gene annotation frequencies in some pre-specified GO classes, in a class-by-class way, followed by p-value adjustment for multiple testing. Enrichment analysis, where a list of genes is compared against a wider universe of genes, is the most common example. Results A new global testing procedure and a method incorporating it are presented. Instead of testing separately for each GO class, a single global test for all classes under consideration is performed. The test is based on the distance between the functional profiles, defined as the joint frequencies of annotation in a given set of GO classes. These classes may be chosen at one or more GO levels. The new global test is more powerful and accurate with respect to type I errors than the usual class-by-class approach. When applied to some real datasets, the results suggest that the method may also provide useful information that complements the tests performed using a class-by-class approach if gene counts are sparse in some classes. An R library, goProfiles, implements these methods and is available from Bioconductor, http://bioconductor.org/packages/release/bioc/html/goProfiles.html. Conclusions The method provides an inferential basis for deciding whether two lists are functionally different. For global comparisons it is preferable to the global chi-square test of homogeneity. Furthermore, it may provide additional information if used in conjunction with class-by-class methods.

  13. Interlaboratory test comparison among Environmental Radioactivity Laboratories using the ISO/IUPAC/AOAC Protocol

    International Nuclear Information System (INIS)

    Romero, L.; Ramos, L.; Salas, R.

    1998-01-01

    World-wide acceptance of results from radiochemical analyses requires reliable, traceable and comparable measurements to SI units, particularly when data sets generated by laboratories are to contribute to evaluation of data from environmental pollution research and monitoring programmes. The Spanish Nuclear Safety Council (CSN) organizes in collaboration with CIEMAT periodical interlaboratory test comparisons for environmental radioactivity laboratories aiming to provide them with the necessary means to asses the quality of their results. This paper presents data from the most recent exercise which, for the first time, was evaluated following the procedure recommended in the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories (1). The test sample was a Reference Material provided by the IAEA-AQCS, a lake sediment containing the following radionuclides: k-40, Ra-226, Ac-228, Cs-137, Sr-90, Pu-(239+240). The results of the proficiency test were computed for the 28 participating laboratories using the z-score approach, the evaluation of the exercises is presented in the paper. The use of a z-score classification has demonstrated to provide laboratories with a more objective means of assessing and demonstrating the reliability of the data they are producing. Analytical proficiency of the participating laboratories has been found to be satisfactory in 57 to 100 percent of cases. (1)- The International harmonized protocol for the proficiency testing of (chemical) analytical laboratories. Pure and Appl. Chem. Vol. 65, n 9, pp. 2123-2144, 1993 IUPAC. GB (Author) 3 refs

  14. Efficient RNA structure comparison algorithms.

    Science.gov (United States)

    Arslan, Abdullah N; Anandan, Jithendar; Fry, Eric; Monschke, Keith; Ganneboina, Nitin; Bowerman, Jason

    2017-12-01

    Recently proposed relative addressing-based ([Formula: see text]) RNA secondary structure representation has important features by which an RNA structure database can be stored into a suffix array. A fast substructure search algorithm has been proposed based on binary search on this suffix array. Using this substructure search algorithm, we present a fast algorithm that finds the largest common substructure of given multiple RNA structures in [Formula: see text] format. The multiple RNA structure comparison problem is NP-hard in its general formulation. We introduced a new problem for comparing multiple RNA structures. This problem has more strict similarity definition and objective, and we propose an algorithm that solves this problem efficiently. We also develop another comparison algorithm that iteratively calls this algorithm to locate nonoverlapping large common substructures in compared RNAs. With the new resulting tools, we improved the RNASSAC website (linked from http://faculty.tamuc.edu/aarslan ). This website now also includes two drawing tools: one specialized for preparing RNA substructures that can be used as input by the search tool, and another one for automatically drawing the entire RNA structure from a given structure sequence.

  15. A simple test of choice stepping reaction time for assessing fall risk in people with multiple sclerosis.

    Science.gov (United States)

    Tijsma, Mylou; Vister, Eva; Hoang, Phu; Lord, Stephen R

    2017-03-01

    Purpose To determine (a) the discriminant validity for established fall risk factors and (b) the predictive validity for falls of a simple test of choice stepping reaction time (CSRT) in people with multiple sclerosis (MS). Method People with MS (n = 210, 21-74y) performed the CSRT, sensorimotor, balance and neuropsychological tests in a single session. They were then followed up for falls using monthly fall diaries for 6 months. Results The CSRT test had excellent discriminant validity with respect to established fall risk factors. Frequent fallers (≥3 falls) performed significantly worse in the CSRT test than non-frequent fallers (0-2 falls). With the odds of suffering frequent falls increasing 69% with each SD increase in CSRT (OR = 1.69, 95% CI: 1.27-2.26, p = falls in people with MS. This test may prove useful in documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions. Implications for rehabilitation Good choice stepping reaction time (CSRT) is required for maintaining balance. A simple low-tech CSRT test has excellent discriminative and predictive validity in relation to falls in people with MS. This test may prove useful documenting longitudinal changes in fall risk in relation to MS disease progression and effects of interventions.

  16. The Symbol Digit Modalities Test as sentinel test for cognitive impairment in multiple sclerosis

    NARCIS (Netherlands)

    Van Schependom, J.; D'hooghe, M. B.; Cleynhens, K.; D'hooge, M.; Haelewyck, M. C.; De Keyser, J.; Nagels, G.

    Background and purpose: Cognitive impairment (CI) is found in about half of the multiple sclerosis (MS) population and is an important contributor to employment status and social functioning. CI is encountered in all disease stages and correlates only moderately with disease duration or Expanded

  17. Social attribution test--multiple choice (SAT-MC) in schizophrenia: comparison with community sample and relationship to neurocognitive, social cognitive and symptom measures.

    Science.gov (United States)

    Bell, Morris D; Fiszdon, Joanna M; Greig, Tamasine C; Wexler, Bruce E

    2010-09-01

    This is the first report on the use of the Social Attribution Task - Multiple Choice (SAT-MC) to assess social cognitive impairments in schizophrenia. The SAT-MC was originally developed for autism research, and consists of a 64-second animation showing geometric figures enacting a social drama, with 19 multiple choice questions about the interactions. Responses from 85 community-dwelling participants and 66 participants with SCID confirmed schizophrenia or schizoaffective disorders (Scz) revealed highly significant group differences. When the two samples were combined, SAT-MC scores were significantly correlated with other social cognitive measures, including measures of affect recognition, theory of mind, self-report of egocentricity and the Social Cognition Index from the MATRICS battery. Using a cut-off score, 53% of Scz were significantly impaired on SAT-MC compared with 9% of the community sample. Most Scz participants with impairment on SAT-MC also had impairment on affect recognition. Significant correlations were also found with neurocognitive measures but with less dependence on verbal processes than other social cognitive measures. Logistic regression using SAT-MC scores correctly classified 75% of both samples. Results suggest that this measure may have promise, but alternative versions will be needed before it can be used in pre-post or longitudinal designs. (c) 2009 Elsevier B.V. All rights reserved.

  18. Comparison between the Counter Immunoelectrophoresis Test and Mouse Neutralization Test for the Detection of Antibodies against Rabies Virus in Dog Sera

    Directory of Open Access Journals (Sweden)

    Luzia Helena Queiroz da Silva

    2002-03-01

    Full Text Available The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET and mouse neutralization test (MNT in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml] and resulted r² = 0.7926 (p < 0.001. The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

  19. Comparison of Multiple Linear Regressions and Neural Networks based QSAR models for the design of new antitubercular compounds.

    Science.gov (United States)

    Ventura, Cristina; Latino, Diogo A R S; Martins, Filomena

    2013-01-01

    The performance of two QSAR methodologies, namely Multiple Linear Regressions (MLR) and Neural Networks (NN), towards the modeling and prediction of antitubercular activity was evaluated and compared. A data set of 173 potentially active compounds belonging to the hydrazide family and represented by 96 descriptors was analyzed. Models were built with Multiple Linear Regressions (MLR), single Feed-Forward Neural Networks (FFNNs), ensembles of FFNNs and Associative Neural Networks (AsNNs) using four different data sets and different types of descriptors. The predictive ability of the different techniques used were assessed and discussed on the basis of different validation criteria and results show in general a better performance of AsNNs in terms of learning ability and prediction of antitubercular behaviors when compared with all other methods. MLR have, however, the advantage of pinpointing the most relevant molecular characteristics responsible for the behavior of these compounds against Mycobacterium tuberculosis. The best results for the larger data set (94 compounds in training set and 18 in test set) were obtained with AsNNs using seven descriptors (R(2) of 0.874 and RMSE of 0.437 against R(2) of 0.845 and RMSE of 0.472 in MLRs, for test set). Counter-Propagation Neural Networks (CPNNs) were trained with the same data sets and descriptors. From the scrutiny of the weight levels in each CPNN and the information retrieved from MLRs, a rational design of potentially active compounds was attempted. Two new compounds were synthesized and tested against M. tuberculosis showing an activity close to that predicted by the majority of the models. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. Quantum internet using code division multiple access

    Science.gov (United States)

    Zhang, Jing; Liu, Yu-xi; Özdemir, Şahin Kaya; Wu, Re-Bing; Gao, Feifei; Wang, Xiang-Bin; Yang, Lan; Nori, Franco

    2013-01-01

    A crucial open problem inS large-scale quantum networks is how to efficiently transmit quantum data among many pairs of users via a common data-transmission medium. We propose a solution by developing a quantum code division multiple access (q-CDMA) approach in which quantum information is chaotically encoded to spread its spectral content, and then decoded via chaos synchronization to separate different sender-receiver pairs. In comparison to other existing approaches, such as frequency division multiple access (FDMA), the proposed q-CDMA can greatly increase the information rates per channel used, especially for very noisy quantum channels. PMID:23860488

  1. Empirical Power Comparison Of Goodness of Fit Tests for Normality In The Presence of Outliers

    International Nuclear Information System (INIS)

    Saculinggan, Mayette; Balase, Emily Amor

    2013-01-01

    Most statistical tests such as t-tests, linear regression analysis and Analysis of Variance (ANOVA) require the normality assumptions. When the normality assumption is violated, interpretation and inferences may not be reliable. Therefore it is important to assess such assumption before using any appropriate statistical test. One of the commonly used procedures in determining whether a random sample of size n comes from a normal population are the goodness-of-fit tests for normality. Several studies have already been conducted on the comparison of the different goodness-of-fit(see, for example [2]) but it is generally limited to the sample size or to the number of GOF tests being compared(see, for example [2] [5] [6] [7] [8]). This paper compares the power of six formal tests of normality: Kolmogorov-Smirnov test (see [3]), Anderson-Darling test, Shapiro-Wilk test, Lilliefors test, Chi-Square test (see [1]) and D'Agostino-Pearson test. Small, moderate and large sample sizes and various contamination levels were used to obtain the power of each test via Monte Carlo simulation. Ten thousand samples of each sample size and contamination level at a fixed type I error rate α were generated from the given alternative distribution. The power of each test was then obtained by comparing the normality test statistics with the respective critical values. Results show that the power of all six tests is low for small sample size(see, for example [2]). But for n = 20, the Shapiro-Wilk test and Anderson – Darling test have achieved high power. For n = 60, Shapiro-Wilk test and Liliefors test are most powerful. For large sample size, Shapiro-Wilk test is most powerful (see, for example [5]). However, the test that achieves the highest power under all conditions for large sample size is D'Agostino-Pearson test (see, for example [9]).

  2. Comparison of attitude determination approaches using multiple Global Positioning System (GPS antennas

    Directory of Open Access Journals (Sweden)

    Wang Bing

    2013-02-01

    Full Text Available GPS-based attitude system is an important research field, since it is a valuable technique for the attitude determination of platforms. There exist two classes approaches for attitude determination using the GPS. The one determines attitude via baseline estimates in two frames, the other one solves for attitude by incorporating the attitude parameters directly into the GPS measurements. However, comparisons between these two classes approaches have been unexplored. First of all, two algorithms are introduced in detail which on behalf of these two kinds of approaches. Then we present numerical simulations demonstrating the performance of our algorithms and provide a comparison evaluating.

  3. Multiple function benefit - cost comparison of conservation buffer placement strategies

    Science.gov (United States)

    Z. Qiu; M.G. Dosskey

    2012-01-01

    Conservation buffers are considered to be effective practices for repairing impaired streams and restoring multiple ecosystem functions in degraded agricultural watersheds. Six different planning strategies for targeting their placement within watersheds were compared in terms of cost-effectiveness for environmental improvement in the 144 km² Neshanic River...

  4. Comparisons of MOVES Light-duty Gasoline NOx Emission Rates with Real-world Measurements

    Science.gov (United States)

    Choi, D.; Sonntag, D.; Warila, J.

    2017-12-01

    Recent studies have shown differences between air quality model estimates and monitored values for nitrogen oxides. Several studies have suggested that the discrepancy between monitored and modeled values is due to an overestimation of NOx from mobile sources in EPA's emission inventory, particularly for light-duty gasoline vehicles. EPA's MOtor Vehicle Emission Simulator (MOVES) is an emission modeling system that estimates emissions for cars, trucks and other mobile sources at the national, county, and project level for criteria pollutants, greenhouse gases, and air toxics. Studies that directly measure vehicle emissions provide useful data for evaluating MOVES when the measurement conditions are properly accounted for in modeling. In this presentation, we show comparisons of MOVES2014 to thousands of real-world NOx emissions measurements from individual light-duty gasoline vehicles. The comparison studies include in-use vehicle emissions tests conducted on chassis dynamometer tests in support of Denver, Colorado's Vehicle Inspection & Maintenance Program and remote sensing data collected using road-side instruments in multiple locations and calendar years in the United States. In addition, we conduct comparisons of MOVES predictions to fleet-wide emissions measured from tunnels. We also present details on the methodology used to conduct the MOVES model runs in comparing to the independent data.

  5. Modal testing and analysis of NOVA laser structures

    International Nuclear Information System (INIS)

    Burdick, R.B.; Weaver, H.J.; Pastrnak, J.W.

    1984-09-01

    NOVA, currently the world's most powerful laser system, is an ongoing project at the Lawrence Livermore National Laboratory in California. The project seeks to develop a feasible method of achieving controlled fusion reaction, initiated by multiple laser beams targeted on a tiny fuel pellet. The NOVA system consists of several large steel framed structures, the largest of which is the Target Chamber Tower. In conjunction with design engineers, the tower was first modelled and analyzed by sophisticated finite element techniques. A modal test was then conducted on the tower structure to evaluate its vibrational characteristics and seismic integrity as well as for general comparison to the finite element results. This paper will discuss the procedure used in the experimental modal analysis and the results obtained from that test

  6. Abbreviation modalities of nitrogen multiple-breath washout tests in school children with obstructed lung disease

    DEFF Research Database (Denmark)

    Green, Kent; Ejlertsen, Jacob S; Madsen, Astrid

    2016-01-01

    , the lung clearance index, calculated as lung volume turnovers required to reach 2.5% of the starting N2 concentration (LCI2.5 ). METHODS: Cross-sectional study of triplicate N2 MBW measurements obtained in cystic fibrosis (CF) patients (N = 60), primary ciliary dyskinesia (PCD) patients (N = 28......RATIONALE: Nitrogen multiple-breath washout (N2 MBW) is a promising tool for assessing early lung damage in children with chronic obstructive pulmonary disease, but it can be a time-consuming procedure. We compared alternative test-shortening endpoints with the most commonly reported N2 MBW outcome...... MBW runs in each session. N2 MBW endpoints were analyzed as z-scores calculated from healthy controls. RESULTS: In PCD, Cn@TO6 and LCI2.5 exhibited similar values (mean [95%CI] difference: 0.33 [-0.24; 0.90] z-scores), reducing the test duration by one-third (5.4 min; 95%CI: 4.0; 6.8). All other...

  7. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva; Esclerosis multiple test de los 4 humores: liquido cefalorraquideo, suero, lagrimas y saliva

    Energy Technology Data Exchange (ETDEWEB)

    Oehninger Gatti, C; Buzo Del Puerto, R; Chouza Antelo, C; Scotti Bianchi, C; Cibils, D; Alcantara Pelaez, J; Gomez, A; Heuguerot Oliveira, C

    1994-12-15

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [Spanish] Se estudiaron 4 fluidos biologicos de facil acceso a la exploracion inmune (liquido cefalorraquideo, suero, lagrimas y saliva) en 25 pacientes con Esclerosis Multiple (EM) obtenidos durante un empuje clinico de la enfermedad. El nivel del receptor de Interleukina-2 soluble (RsIL-2) se encontro significativamente aumentado en por lo menos 3 de estos 4 fluidos, en comparacion con el de los controles normales. La sensibilidad y especificidad de su determinacion para el diagnostico de la afeccion, fue mayor que la de otros parametros inmunoquimicos - distribucion oligoclonal (DO) de inmunoglobulinas (Ig), disbalance de cadenas livianas - y estudios electrofisiologicos -potenciales evocados-. Este metodo es utilizado para establecer un diagnostico mas certero de la Esclerosis Multiple asi como tambien para monitorizar su actividad biologica junto con la resonancia magnetica nuclear (RMN)(Author)

  8. [The influence of high-tone power therapy on the functional status of patients with multiple sclerosis].

    Science.gov (United States)

    Kubsik, Anna; Klimkiewicz, Paulina; Klimkiewicz, Robert; Jankowska, Katarzyna; Jankowska, Agnieszka; Woldańska-Okońska, Marta

    2014-07-01

    Multiple sclerosis is a chronic, inflammatory, demyelinating disease of the central nervous system, which is characterized by diverse symptomatology. Most often affects people at a young age gradually leading to their disability. Looking for new therapies to alleviate neurological deficits caused by the disease. One of the alternative methods of therapy is high - tone power therapy. The article is a comparison of high-tone power therapy and kinesis in improving patients with multiple sclerosis. The aim of this study was to evaluate the effectiveness of high-tone power therapy and exercises in kinesis on the functional status of patients with multiple sclerosis. The study involved 20 patients with multiple sclerosis, both sexes, treated at the Department of Rehabilitation and Physical Medicine in Lodz. Patients were randomly divided into two groups studied. In group high-tone power therapy applied for 60 minutes, while in group II were used exercises for kinesis. Treatment time for both groups of patients was 15 days. To assess the functional status scale was used: Expanded Disability Status Scale of Kurtzke (EDSS), as well as by Barthel ADL Index. Assessment of quality of life were made using MSQOL Questionnaire-54. For the evaluation of gait and balance using Tinetti scale, and pain VAS rated, and Laitinen. Changes in muscle tone was assessed on the basis of the Ashworth scale. Both group I and II improved on scales conducted before and after therapy. In group I, in which the applied high-tone power therapy, reported statistically significant results in 9 out of 10 tested parameters, while in group II, which was used in the exercises in kinesis an improvement in 6 out of 10 tested parameters. Correlating the results of both the test groups in relation to each other did not show statistically significant differences. High-Tone Power Therapy beneficial effect on the functional status of patients with multiple sclerosis. Obtaining results in terms of number of tested

  9. Stresses and displacements in vessels due to loads imposed by single and multiple piping attachments

    International Nuclear Information System (INIS)

    Wong, F.M.G.; Craft, W.J.; East, G.H.

    1985-01-01

    The Fourier solution for thin shell equations models pressure vessels as continuous simply connected surfaces with local loads. The technique allows placement of tractions with combinations of radial, shear, and axial components. Unlike Bijlaard, the solution in this paper includes loads placed at any position along the cylinder. Stiffness and the enhanced load-carrying capacity that internal pressure gives to thin vessels can be simulated. Numerical convergence problems are reduced by an improved displacement-load algorithm, and by use of load sites that allow the circular functions to be compactly grouped. A variety of loading distributions may be analyzed including large and small nozzles near and away from centerlines. Both rectangular and circular attachments are simulated. Through superposition, multiple attachments with their own loads may be examined. The attachments to the vessel may be either rigid or soft. A comparison to analytical results from Bijlaard shows excellent agreement. Comparisons with experimental tests on an API-650 nozzle on a storage tank are in good agreement. Variations between experimental and calculated results are primarily caused by assuming a simply supported base in the calculation, whereas in the experimental test, the base is more nearly fixed

  10. Comparison of heat-testing methodology.

    Science.gov (United States)

    Bierma, Mark M; McClanahan, Scott; Baisden, Michael K; Bowles, Walter R

    2012-08-01

    Patients with irreversible pulpitis occasionally present with a chief complaint of sensitivity to heat. To appropriately diagnose the offending tooth, a variety of techniques have been developed to reproduce this chief complaint. Such techniques cause temperature increases that are potentially damaging to the pulp. Newer electronic instruments control the temperature of a heat-testing tip that is placed directly against a tooth. The aim of this study was to determine which method produced the most consistent and safe temperature increase within the pulp. This consistency facilitates the clinician's ability to differentiate between a normal pulp and irreversible pulpitis. Four operators applied the following methods to each of 4 extracted maxillary premolars (for a total of 16 trials per method): heated gutta-percha, heated ball burnisher, hot water, and a System B unit or Elements unit with a heat-testing tip. Each test was performed for 60 seconds, and the temperatures were recorded via a thermocouple in the pulp chamber. Analysis of the data was performed by using the intraclass correlation coefficient. The least consistent warming was found with hot water. The heat-testing tip also demonstrated greater consistency between operators compared with the other methods. Hot water and the heated ball burnisher caused temperature increases high enough to damage pulp tissue. The Elements unit with a heat-testing tip provides the most consistent warming of the dental pulp. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  12. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen; Schuster, Gerard T.

    2017-01-01

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  13. Comparison of grey matter atrophy between patients with neuromyelitis optica and multiple sclerosis: A voxel-based morphometry study

    International Nuclear Information System (INIS)

    Duan Yunyun; Liu Yaou; Liang Peipeng; Jia Xiuqin; Yu Chunshui; Qin Wen; Sun Hui; Liao Zhangyuan; Ye Jing; Li Kuncheng

    2012-01-01

    Purpose: Previous studies have established regional grey matter (GM) loss in multiple sclerosis (MS). However, whether there is any regional GM atrophy in neuromyelitis optica (NMO) and the difference between NMO and MS is unclear. The present study addresses this issue by voxel-based morphometry (VBM). Methods: Conventional magnetic resonance imaging (MRI) and T1-weighted three-dimensional MRI were obtained from 26 NMO patients, 26 relapsing–remitting MS (RRMS) patients, and 26 normal controls. An analysis of covariance model assessed with cluster size inference was used to compare GM volume among three groups. The correlations of GM volume changes with disease duration, expanded disability status scale (EDSS) and brain T2 lesion volume (LV) were analyzed. Results: GM atrophy was found in NMO patients in several regions of frontal, temporal, parietal lobes and insula (uncorrected, p < 0.001). While extensive GM atrophy was found in RRMS patients, including most cortical regions and the deep grey matter (corrected for multiple comparisons, p < 0.01). Compared with NMO, those with RRMS had significant GM loss in bilateral thalami, caudate, left parahippocampal gyrus, right hippocampus and insula (corrected, p < 0.01). In RRMS group, regional GM loss in right caudate and bilateral thalami were strongly correlated with brain T2LV. Conclusions: Our study found the difference of GM atrophy between NMO and RRMS patients mainly in deep grey matter. The correlational results suggested axonal degeneration from lesions on T2WI may be a key pathogenesis of atrophy in deep grey matter in RRMS.

  14. Multiple infrared bands absorber based on multilayer gratings

    Science.gov (United States)

    Liu, Xiaoyi; Gao, Jinsong; Yang, Haigui; Wang, Xiaoyi; Guo, Chengli

    2018-03-01

    The present study offers an Ag/Si multilayer-grating microstructure based on an Si substrate. The microstructure exhibits designable narrowband absorption in multiple infrared wavebands, especially in mid- and long-wave infrared atmospheric windows. We investigate its resonance mode mechanism, and calculate the resonance wavelengths by the Fabry-Perot and metal-insulator-metal theories for comparison with the simulation results. Furthermore, we summarize the controlling rules of the absorption peak wavelength of the microstructure to provide a new method for generating a Si-based device with multiple working bands in infrared.

  15. Multiple endocrine neoplasia type 2: achievements and current challenges

    Directory of Open Access Journals (Sweden)

    Andreas Machens

    2012-01-01

    Full Text Available Incremental advances in medical technology, such as the development of sensitive hormonal assays for routine clinical care, are the drivers of medical progress. This principle is exemplified by the creation of the concept of multiple endocrine neoplasia type 2, encompassing medullary thyroid cancer, pheochromocytoma, and primary hyperparathyroidism, which did not emerge before the early 1960s. This review sets out to highlight key achievements, such as joint biochemical and DNA-based screening of individuals at risk of developing multiple endocrine neoplasia type 2, before casting a spotlight on current challenges which include: (i ill-defined upper limits of calcitonin assays for infants and young children, rendering it difficult to implement the biochemical part of the integrated DNA-based/biochemical concept; (ii our increasingly mobile society in which different service providers are caring for one individual at various stages in the disease process. With familial relationships disintegrating as a result of geographic dispersion, information about the history of the origin family may become sketchy or just unavailable. This is when DNA-based gene tests come into play, confirming or excluding an individual's genetic predisposition to multiple endocrine neoplasia type 2 even before there is any biochemical or clinical evidence of the disease. However, the unrivaled molecular genetic progress in multiple endocrine neoplasia type 2 does not come without a price. Screening may uncover unknown gene sequence variants representing either harmless polymorphisms or pathogenic mutations. In this setting, functional characterization of mutant cells in vitro may generate helpful ancillary evidence with regard to the pathogenicity of gene variants in comparison with established mutations.

  16. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  17. Identification of Misconceptions through Multiple Choice Tasks at Municipal Chemistry Competition Test

    Directory of Open Access Journals (Sweden)

    Dušica D Milenković

    2016-01-01

    Full Text Available In this paper, the level of conceptual understanding of chemical contents among seventh grade students who participated in the municipal Chemistry competition in Novi Sad, Serbia, in 2013 have been examined. Tests for the municipal chemistry competition were used as a measuring instrument, wherein only multiple choice tasks were considered and analyzed. Determination of the level of conceptual understanding of the tested chemical contents was based on the calculation of the frequency of choosing the correct answers. Thereby, identification of areas of satisfactory conceptual understanding, areas of roughly adequate performance, areas of inadequate performance, and areas of quite inadequate performance have been conducted. On the other hand, the analysis of misconceptions was based on the analysis of distractors. The results showed that satisfactory level of conceptual understanding and roughly adequate performance characterize majority of contents, which was expected since only the best students who took part in the contest were surveyed. However, this analysis identified a large number of misunderstandings, as well. In most of the cases, these misconceptions were related to the inability to distinguish elements, compounds, homogeneous and heterogeneous mixtures. Besides, it is shown that students are not familiar with crystal structure of the diamond, and with metric prefixes. The obtained results indicate insufficient visualization of the submicroscopic level in school textbooks, the imprecise use of chemical language by teachers and imprecise use of language in chemistry textbooks.

  18. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.

    Science.gov (United States)

    Faul, Franz; Erdfelder, Edgar; Buchner, Axel; Lang, Albert-Georg

    2009-11-01

    G*Power is a free power analysis program for a variety of statistical tests. We present extensions and improvements of the version introduced by Faul, Erdfelder, Lang, and Buchner (2007) in the domain of correlation and regression analyses. In the new version, we have added procedures to analyze the power of tests based on (1) single-sample tetrachoric correlations, (2) comparisons of dependent correlations, (3) bivariate linear regression, (4) multiple linear regression based on the random predictor model, (5) logistic regression, and (6) Poisson regression. We describe these new features and provide a brief introduction to their scope and handling.

  19. New modelling of transient well test and rate decline analysis for a horizontal well in a multiple-zone reservoir

    International Nuclear Information System (INIS)

    Nie, Ren-Shi; Guo, Jian-Chun; Jia, Yong-Lu; Zhu, Shui-Qiao; Rao, Zheng; Zhang, Chun-Guang

    2011-01-01

    The no-type curve with negative skin of a horizontal well has been found in the current research. Negative skin is very significant to transient well test and rate decline analysis. This paper first presents the negative skin problem where the type curves with negative skin of a horizontal well are oscillatory. In order to solve the problem, we propose a new model of transient well test and rate decline analysis for a horizontal well in a multiple-zone composite reservoir. A new dimensionless definition of r D is introduced in the dimensionless mathematical modelling under different boundaries. The model is solved using the Laplace transform and separation of variables techniques. In Laplace space, the solutions for both constant rate production and constant wellbore pressure production are expressed in a unified formula. We provide graphs and thorough analysis of the new standard type curves for both well test and rate decline analysis; the characteristics of type curves are the reflections of horizontal well production in a multiple-zone reservoir. An important contribution of our paper is that our model removed the oscillation in type curves and thus solved the negative skin problem. We also show that the characteristics of type curves depend heavily on the properties of different zones, skin factor, well length, formation thickness, etc. Our research can be applied to a real case study

  20. REIMEP-22 inter-laboratory comparison: "U Age Dating - Determination of the production date of a uranium certified test sample"

    OpenAIRE

    VENCHIARUTTI CELIA; VARGA ZSOLT; RICHTER Stephan; JAKOPIC Rozle; MAYER Klaus; AREGBE Yetunde

    2015-01-01

    The REIMEP-22 inter-laboratory comparison aimed at determining the production date of a uranium certified test sample (i.e. the last chemical separation date of the material). Participants in REIMEP-22 on "U Age Dating - Determination of the production date of a uranium certified test sample" received one low-enriched 20 mg uranium sample for mass spectrometry measurements and/or one 50 mg uranium sample for D-spectrometry measurements, with an undisclosed value for the production date. They ...

  1. Automatic segmentation of male pelvic anatomy on computed tomography images: a comparison with multiple observers in the context of a multicentre clinical trial

    International Nuclear Information System (INIS)

    Geraghty, John P; Grogan, Garry; Ebert, Martin A

    2013-01-01

    This study investigates the variation in segmentation of several pelvic anatomical structures on computed tomography (CT) between multiple observers and a commercial automatic segmentation method, in the context of quality assurance and evaluation during a multicentre clinical trial. CT scans of two prostate cancer patients (‘benchmarking cases’), one high risk (HR) and one intermediate risk (IR), were sent to multiple radiotherapy centres for segmentation of prostate, rectum and bladder structures according to the TROG 03.04 “RADAR” trial protocol definitions. The same structures were automatically segmented using iPlan software for the same two patients, allowing structures defined by automatic segmentation to be quantitatively compared with those defined by multiple observers. A sample of twenty trial patient datasets were also used to automatically generate anatomical structures for quantitative comparison with structures defined by individual observers for the same datasets. There was considerable agreement amongst all observers and automatic segmentation of the benchmarking cases for bladder (mean spatial variations < 0.4 cm across the majority of image slices). Although there was some variation in interpretation of the superior-inferior (cranio-caudal) extent of rectum, human-observer contours were typically within a mean 0.6 cm of automatically-defined contours. Prostate structures were more consistent for the HR case than the IR case with all human observers segmenting a prostate with considerably more volume (mean +113.3%) than that automatically segmented. Similar results were seen across the twenty sample datasets, with disagreement between iPlan and observers dominant at the prostatic apex and superior part of the rectum, which is consistent with observations made during quality assurance reviews during the trial. This study has demonstrated quantitative analysis for comparison of multi-observer segmentation studies. For automatic segmentation

  2. Can Reduced-Step Polishers Be as Effective as Multiple-Step Polishers in Enhancing Surface Smoothness?

    Science.gov (United States)

    Kemaloglu, Hande; Karacolak, Gamze; Turkun, L Sebnem

    2017-02-01

    The aim of this study was to evaluate the effects of various finishing and polishing systems on the final surface roughness of a resin composite. Hypotheses tested were: (1) reduced-step polishing systems are as effective as multiple-step systems on reducing the surface roughness of a resin composite and (2) the number of application steps in an F/P system has no effect on reducing surface roughness. Ninety discs of a nano-hybrid resin composite were fabricated and divided into nine groups (n = 10). Except the control, all of the specimens were roughened prior to be polished by: Enamel Plus Shiny, Venus Supra, One-gloss, Sof-Lex Wheels, Super-Snap, Enhance/PoGo, Clearfil Twist Dia, and rubber cups. The surface roughness was measured and the surfaces were examined under scanning electron microscope. Results were analyzed with analysis of variance and Holm-Sidak's multiple comparisons test (p One-gloss, Enamel Plus Shiny, and Venus Supra groups. (1) The number of application steps has no effect on the performance of F/P systems. (2) Reduced-step polishers used after a finisher can be preferable to multiple-step systems when used on nanohybrid resin composites. (3) The effect of F/P systems on surface roughness seems to be material-dependent rather than instrument- or system-dependent. Reduced-step systems used after a prepolisher can be an acceptable alternative to multiple-step systems on enhancing the surface smoothness of a nanohybrid composite; however, their effectiveness depends on the materials' properties. (J Esthet Restor Dent 29:31-40, 2017). © 2016 Wiley Periodicals, Inc.

  3. Convergent validity test, construct validity test and external validity test of the David Liberman algorithm

    Directory of Open Access Journals (Sweden)

    David Maldavsky

    2013-08-01

    Full Text Available The author first exposes a complement of a previous test about convergent validity, then a construct validity test and finally an external validity test of the David Liberman algorithm.  The first part of the paper focused on a complementary aspect, the differential sensitivity of the DLA 1 in an external comparison (to other methods, and 2 in an internal comparison (between two ways of using the same method, the DLA.  The construct validity test exposes the concepts underlined to DLA, their operationalization and some corrections emerging from several empirical studies we carried out.  The external validity test examines the possibility of using the investigation of a single case and its relation with the investigation of a more extended sample.

  4. Distinguishing between forensic science and forensic pseudoscience: testing of validity and reliability, and approaches to forensic voice comparison.

    Science.gov (United States)

    Morrison, Geoffrey Stewart

    2014-05-01

    In this paper it is argued that one should not attempt to directly assess whether a forensic analysis technique is scientifically acceptable. Rather one should first specify what one considers to be appropriate principles governing acceptable practice, then consider any particular approach in light of those principles. This paper focuses on one principle: the validity and reliability of an approach should be empirically tested under conditions reflecting those of the case under investigation using test data drawn from the relevant population. Versions of this principle have been key elements in several reports on forensic science, including forensic voice comparison, published over the last four-and-a-half decades. The aural-spectrographic approach to forensic voice comparison (also known as "voiceprint" or "voicegram" examination) and the currently widely practiced auditory-acoustic-phonetic approach are considered in light of this principle (these two approaches do not appear to be mutually exclusive). Approaches based on data, quantitative measurements, and statistical models are also considered in light of this principle. © 2013.

  5. Statistical Power in Evaluations That Investigate Effects on Multiple Outcomes: A Guide for Researchers

    Science.gov (United States)

    Porter, Kristin E.

    2018-01-01

    Researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple testing procedures (MTPs) are statistical…

  6. CR-Calculus and adaptive array theory applied to MIMO random vibration control tests

    Science.gov (United States)

    Musella, U.; Manzato, S.; Peeters, B.; Guillaume, P.

    2016-09-01

    Performing Multiple-Input Multiple-Output (MIMO) tests to reproduce the vibration environment in a user-defined number of control points of a unit under test is necessary in applications where a realistic environment replication has to be achieved. MIMO tests require vibration control strategies to calculate the required drive signal vector that gives an acceptable replication of the target. This target is a (complex) vector with magnitude and phase information at the control points for MIMO Sine Control tests while in MIMO Random Control tests, in the most general case, the target is a complete spectral density matrix. The idea behind this work is to tailor a MIMO random vibration control approach that can be generalized to other MIMO tests, e.g. MIMO Sine and MIMO Time Waveform Replication. In this work the approach is to use gradient-based procedures over the complex space, applying the so called CR-Calculus and the adaptive array theory. With this approach it is possible to better control the process performances allowing the step-by-step Jacobian Matrix update. The theoretical bases behind the work are followed by an application of the developed method to a two-exciter two-axis system and by performance comparisons with standard methods.

  7. Comparison of Multiple-Microphone and Single-Loudspeaker Adaptive Feedback/Echo Cancellation Systems

    DEFF Research Database (Denmark)

    Guo, Meng; Elmedyb, Thomas Bo; Jensen, Søren Holdt

    2011-01-01

    Recently, we introduced a frequency domain measure - the power transfer function - to predict the convergence rate, system stability bound and the steady-state behavior across time and frequency of a least mean square based feedback/echo cancellation algorithm in a general multiple-microphone and......Recently, we introduced a frequency domain measure - the power transfer function - to predict the convergence rate, system stability bound and the steady-state behavior across time and frequency of a least mean square based feedback/echo cancellation algorithm in a general multiple...

  8. Predictors of activity and participation across neurodegenerative conditions: a comparison of people with motor neurone disease, multiple sclerosis and Parkinson's disease.

    Science.gov (United States)

    Morley, David; Dummett, Sarah; Kelly, Laura; Fitzpatrick, Ray; Jenkinson, Crispin

    2018-02-17

    Comparisons between neurological conditions have the potential to inform service providers by identifying particular areas of difficulty experienced by affected individuals. This study aimed to identify predictors of activity and participation in people with motor neurone disease (MND), people with multiple sclerosis (MS) and people with Parkinson's Disease (PD). The Oxford Participation and Activities Questionnaire (Ox-PAQ) and Medical Outcomes Study 36-Item Short Form Survey (MOS SF-36) were administered by postal survey to 386 people with a confirmed diagnosis of MND, MS or PD. Data analyses focused on stepwise regression analyses in order to identify predictors of activity and participation in the three conditions assessed. Three hundred and thirty four participants completed the survey, a response rate of 86.5%. Regression analyses identified multiple predictors of activity and participation dependent on Ox-PAQ domain and disease group, the most prominent being social and physical functioning as measured by the MOS SF-36. Results indicate that the physical and social consequences of neurological illness are of greatest relevance to people experiencing the conditions assessed. Whilst the largely inevitable physical implications of disease take hold, emphasis should be placed on the avoidance of social withdrawal and isolation, and the maintenance of social engagement should become a significant priority.

  9. Finger and foot tapping as alternative outcomes of upper and lower extremity function in multiple sclerosis.

    Science.gov (United States)

    Tanigawa, Makoto; Stein, Jason; Park, John; Kosa, Peter; Cortese, Irene; Bielekova, Bibiana

    2017-01-01

    While magnetic resonance imaging contrast-enhancing lesions represent an excellent screening tool for disease-modifying treatments in relapsing-remitting multiple sclerosis (RRMS), this biomarker is insensitive for testing therapies against compartmentalized inflammation in progressive multiple sclerosis (MS). Therefore, alternative sensitive outcomes are needed. Using machine learning, clinician-acquired disability scales can be combined with timed measures of neurological functions such as walking speed (e.g. 25-foot walk; 25FW) or fine finger movements (e.g. 9-hole peg test; 9HPT) into sensitive composite clinical scales, such as the recently developed combinatorial, weight-adjusted disability scale (CombiWISE). Ideally, these complementary simplified measurements of certain neurological functions could be performed regularly at patients' homes using smartphones. We asked whether tests amenable to adaptation to smartphone technology, such as finger and foot tapping have comparable sensitivity and specificity to current non-clinician-acquired disability measures. We observed that finger and foot tapping can differentiate RRMS and progressive MS in a cross-sectional study and can also measure yearly and two-year disease progression in the latter, with better power (based on z-scores) in comparison to currently utilized 9HPT and 25FW. Replacing the 9HPT and 25FW with simplified tests broadly adaptable to smartphone technology may enhance the power of composite scales for progressive MS.

  10. Multiple sclerosis

    DEFF Research Database (Denmark)

    Stenager, E; Knudsen, L; Jensen, K

    1994-01-01

    In a cross-sectional study of 94 patients (42 males, 52 females) with definite multiple sclerosis (MS) in the age range 25-55 years, the correlation of neuropsychological tests with the ability to read TV-subtitles and with the use of sedatives is examined. A logistic regression analysis reveals...

  11. A Research on the Comparison of the MultipleIntelligince Types of the Candidates Who Succeeded and Failedinthe Entrance Exams of Physical Educationand Sports School

    Directory of Open Access Journals (Sweden)

    Murat KUL

    2014-07-01

    Full Text Available The purpose of the study , candidates who participated in a special aptitude test of Physical Education and Sports School are compared those who were eligible to register with the win of Multiple Inte lligence Areas. In the research Scan model was used. Within the investigation, in 785 candidates who applied Bartin Universty School of Physical Education and Sports Special Ability Test for 2013 - 2014 academic year, 536 volunteer candidates who have average age x yaş = 21.15± 2.66 constitude. As data collection tool, belogns to the candidates personal information form and “Multiple Intelligences Inventory” which was developed by Özden (2003 for he identification of multiple intellegences was applied. Reliability coefficient was discovered as .96. In evaluation of data, SPSS data an alysis program was used. In evaluation of data, frequency, average, standard, deviation from descriptive statistical techniques was used. Also by taking into account normal distribution of the data, Independent Sample T - test of statistical techniques was u sed. In considering the findings of the study “Bodily - Kinesthetic Intelligence” which is a field of Multiple Intelligences of candidates as statistically significant diffirence was found in the area. Candidates winning higher than avarage scores candidates who can not win are seen to have. Also, “Social - Interpersonal Intelligence” of candidates qualifing to register with who can not qualify to register statistically significant results were observed in the levels. Winning candidates in this area compared t o the candidates who win more than others, it is concluded that they carry the dominant features. As a result of “Verbal - Linguistic Intelligence”, “Logical - Mathematical Intelligence”, “Musical - Rhythmic Intelligence”, “Bodily - Kinesthetic Intelligence, “Soci al - Interpersonal Intelligence” of Multiple Intelligence Areas candidates who participated in Physical Education

  12. Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    Science.gov (United States)

    Makarova, Anastasia; Gottschalk, Bernard; Sauerwein, Wolfgang

    2017-07-06

    Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensitive to the distribution of angles leaving the target, the relevant theory is the Molière/Fano/Hanson variant of Molière theory (Gottschalk et al 1993 Nucl. Instrum. Methods Phys. Res. B 74 467-90). For transverse spreading of the beam in the target itself, the theory of Preston and Koehler (Gottschalk (2012 arXiv:1204.4470)) holds. Therefore, in this paper we compare Geant4 simulations, using the Urban and Wentzel models of MCS, with theory rather than experiment, revealing trends which would otherwise be obscured by experimental scatter. For medium-energy (radiotherapy) protons, and low-Z (water-like) target materials, Wentzel appears to be better than Urban in simulating the distribution of outgoing angles. For beam spreading in the target itself, the two models are essentially equal.

  13. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison.

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G Prasad; Tiwari, Sarvada C; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated.

  14. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122

  15. Development test of multiple die with hydraulic compensation and auto lubrication

    International Nuclear Information System (INIS)

    Chen Mengyou; Zhang Xichang; Zhu Ninghua; Liu Zichang

    1988-05-01

    Multiple die with hydraulic compensating device adopts the design of multidies gathering in a common grease cavity, using high temperature lubricating grease as the pressure compensating medium. According to Pascal's Law, each die will receive equal pressure during the process of pressing. Such device changes the equi-volume pressing mode of single mechanical die to equipressure pressing mode of multiple die in nuclear fuel element production, thus improves the quality and raises the quantity of nuclear fuel and powder ceramic products, giving a better economic benefit

  16. Self-reported changes in quality of life among people with multiple sclerosis who have participated in treatments based on collaboration between conventional healthcare providers and CAM practitioners

    DEFF Research Database (Denmark)

    Bjerre, Liv; Henningsen, Inge Biehl; Skovgaard, Lasse

    2011-01-01

    Aim of the study: This study assesses the changes in self-reported quality of life (QoL) from hospitalisation to 18 months later among people with multiple sclerosis (MS) who have participated in treatments based on collaboration between conventional healthcare providers and CAM practitioners...... interventions by a team of five healthcare providers and five CAM practitioners. The outcome measure was a change in QoL (measured as the difference in total score and sub-scores on the Functional Assessment of Multiple Sclerosis (FAMS) QoL scale). Results: From hospitalisation and through an 18-month period....... Materials and methods: A pre- and post-test evaluation design including an intervention group and a comparison group was employed in this study. 142 people with MS were analysed in the intervention group and 142 in the comparison group. Each person in the intervention group was treated with combined...

  17. Zika detection: comparison of methodologies

    Directory of Open Access Journals (Sweden)

    Tatiana Elias Colombo

    Full Text Available ABSTRACT Many countries in the Americas have detected local transmission of multiple arboviruses that cause febrile illnesses. Therefore, laboratory testing has become an important tool for confirming the etiology of these diseases. The present study aimed to compare the sensitivity and specificity of three different Zika virus detection assays. One hundred serum samples from patients presenting with acute febrile symptoms were tested using a previously reported TaqMan® RT-qPCR assay. We used a SYBR® Green RT-qPCR and a conventional PCR methodologies to compare the results. Of the samples that were determined to be negative by the TaqMan® RT-qPCR assay, 100% (Kappa = 0.670 were also found to be negative by SYBR® Green RT-qPCR based on Tm comparison; however, 14% (Kappa = 0.035 were found to be positive by conventional PCR followed by agarose gel electrophoresis. The differences between the ZIKV strains circulating worldwide and the low viremia period can compromise diagnostic accuracy and thereby the accuracy of outbreak data. Therefore, improved assays are required to improve the diagnosis and surveillance of arbovirus.

  18. Comparison of infrared and 3D digital image correlation techniques applied for mechanical testing of materials

    Science.gov (United States)

    Krstulović-Opara, Lovre; Surjak, Martin; Vesenjak, Matej; Tonković, Zdenko; Kodvanj, Janoš; Domazet, Željko

    2015-11-01

    To investigate the applicability of infrared thermography as a tool for acquiring dynamic yielding in metals, a comparison of infrared thermography with three dimensional digital image correlation has been made. Dynamical tension tests and three point bending tests of aluminum alloys have been performed to evaluate results obtained by IR thermography in order to detect capabilities and limits for these two methods. Both approaches detect pastification zone migrations during the yielding process. The results of the tension test and three point bending test proved the validity of the IR approach as a method for evaluating the dynamic yielding process when used on complex structures such as cellular porous materials. The stability of the yielding process in the three point bending test, as contrary to the fluctuation of the plastification front in the tension test, is of great importance for the validation of numerical constitutive models. The research proved strong performance, robustness and reliability of the IR approach when used to evaluate yielding during dynamic loading processes, while the 3D DIC method proved to be superior in the low velocity loading regimes. This research based on two basic tests, proved the conclusions and suggestions presented in our previous research on porous materials where middle wave infrared thermography was applied.

  19. Efficacy of Inactivation of Human Enteroviruses by Multiple ...

    Science.gov (United States)

    Ultraviolet (UV) light has been successfully used for treating a broad suite of pathogens without the concomitant formation of carcinogenic disinfection by-products (DBPs). However, conventional mercury UV lamps have some practical limitations in water treatment applications, such as the inefficiency of energy consumption and more importantly potential mercury contamination upon disposal of the lamps. The recent invention of a novel light-emitting-diodes (LED) device generating germicidal UV wavelengths could eliminate the aforementioned limitations. In this study, we investigated the efficacy of multiple-wavelength UV LEDs for inactivating USEPA contaminant candidate list (CCL) RNA enteroviruses. Of 12 enterovirus species, serotype representatives of the four human enteric species (enterovirus A-D) such as coxsackievirus A10 (CVA10), echovirus 30 (Echo30), poliovirus 1 (PV1), and enterovirus 70 (EV70) respectively were selected as testing RNA viruses. Bench-scale performance evaluation was conducted using a collimated beam (CB) apparatus with LEDs emitting at 260 nm, 280 nm, and the combination of 260|280 nm together, as well as a monochromatic low-pressure (LP) UV lamp at 254 nm for comparison. The CB tests were performed with mixed stocks of four viruses. Infectious virus concentrations were determined using an integrated cell culture reverse transcriptase quantitative PCR (ICC-RTqPCR). The 260 nm LED was most effective at inactivating all enteroviruses teste

  20. Interactive comparison and remediation of collections of macromolecular structures.

    Science.gov (United States)

    Moriarty, Nigel W; Liebschner, Dorothee; Klei, Herbert E; Echols, Nathaniel; Afonine, Pavel V; Headd, Jeffrey J; Poon, Billy K; Adams, Paul D

    2018-01-01

    Often similar structures need to be compared to reveal local differences throughout the entire model or between related copies within the model. Therefore, a program to compare multiple structures and enable correction any differences not supported by the density map was written within the Phenix framework (Adams et al., Acta Cryst 2010; D66:213-221). This program, called Structure Comparison, can also be used for structures with multiple copies of the same protein chain in the asymmetric unit, that is, as a result of non-crystallographic symmetry (NCS). Structure Comparison was designed to interface with Coot(Emsley et al., Acta Cryst 2010; D66:486-501) and PyMOL(DeLano, PyMOL 0.99; 2002) to facilitate comparison of large numbers of related structures. Structure Comparison analyzes collections of protein structures using several metrics, such as the rotamer conformation of equivalent residues, displays the results in tabular form and allows superimposed protein chains and density maps to be quickly inspected and edited (via the tools in Coot) for consistency, completeness and correctness. © 2017 The Protein Society.