  1. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  2. Reduction of bias in neutron multiplicity assay using a weighted point model

    Energy Technology Data Exchange (ETDEWEB)

    Geist, W. H. (William H.); Krick, M. S. (Merlyn S.); Mayo, D. R. (Douglas R.)

    2004-01-01

    Accurate assay of most common plutonium samples was the development goal for the nondestructive assay technique of neutron multiplicity counting. Over the past 20 years the technique has been proven for relatively pure oxides and small metal items. Unfortunately, the technique results in large biases when assaying large metal items. Limiting assumptions, such as unifoh multiplication, in the point model used to derive the multiplicity equations causes these biases for large dense items. A weighted point model has been developed to overcome some of the limitations in the standard point model. Weighting factors are detemiined from Monte Carlo calculations using the MCNPX code. Monte Carlo calculations give the dependence of the weighting factors on sample mass and geometry, and simulated assays using Monte Carlo give the theoretical accuracy of the weighted-point-model assay. Measured multiplicity data evaluated with both the standard and weighted point models are compared to reference values to give the experimental accuracy of the assay. Initial results show significant promise for the weighted point model in reducing or eliminating biases in the neutron multiplicity assay of metal items. The negative biases observed in the assay of plutonium metal samples are caused by variations in the neutron multiplication for neutrons originating in various locations in the sample. The bias depends on the mass and shape of the sample and depends on the amount and energy distribution of the ({alpha},n) neutrons in the sample. When the standard point model is used, this variable-multiplication bias overestimates the multiplication and alpha values of the sample, and underestimates the plutonium mass. The weighted point model potentially can provide assay accuracy of {approx}2% (1 {sigma}) for cylindrical plutonium metal samples < 4 kg with {alpha} < 1 without knowing the exact shape of the samples, provided that the ({alpha},n) source is uniformly distributed throughout the

  3. Geometry-based multiplication correction for passive neutron coincidence assay of materials with variable and unknown (α,n) neutron rates

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.

    1993-02-01

    We have studied the problem of assaying impure plutonium-bearing materials using passive neutron coincidence counting. We have developed a technique to analyze neutron coincidence data from impure plutonium samples that uses the bulk geometry of the sample to correct for multiplication in samples for which the (α,n) neutron production rate is unknown. This technique can be applied to any impure plutonium-bearing material whose matrix constituents are approximately constant, whose self-multiplication is low to moderate, whose plutonium isotopic composition is known and not substantially varying, and whose bulk geometry is measurable or can be derived. This technique requires a set of reference materials that have well-characterized plutonium contents. These reference materials are measured once to derive a calibration that is specific to the neutron detector and the material. The technique has been applied to molten salt extraction residues, PuF 4 samples that have a variable salt matrix, and impure plutonium oxide samples. It is also applied to pure plutonium oxide samples for comparison. Assays accurate to 4% (1 σ) were obtained for impure samples measured in a High-Level Neutron Coincidence Counter II. The effects on the technique of variations in neutron detector efficiency with energy and the effects of neutron capture in the sample are discussed

  4. Comparison of mRNA Splicing Assay Protocols across Multiple Laboratories

    DEFF Research Database (Denmark)

    Whiley, Phillip J; de la Hoya, Miguel; Thomassen, Mads

    2014-01-01

    Accurate evaluation of unclassified sequence variants in cancer predisposition genes is essential for clinical management and depends on a multifactorial analysis of clinical, genetic, pathologic, and bioinformatic variables and assays of transcript length and abundance. The integrity of assay data...

  5. Variable dead time counters. 1 - theoretical responses and the effects of neutron multiplication

    International Nuclear Information System (INIS)

    Lees, E.W.; Hooton, B.W.

    1978-10-01

    A theoretical expression is derived for calculating the response of any variable dead time counter (VDC) used in the passive assay of plutonium by neutron counting of the natural spontaneous fission activity. The effects of neutron multiplication in the sample arising from interactions of the original spontaneous fission neutrons is shown to modify the linear relationship between VDC signal and Pu mass. Numerical examples are shown for the Euratom VDC and a systematic investigation of the various factors affecting neutron multiplication is reported. Limited comparisons between the calculations and experimental data indicate provisional validity of the calculations. (author)

  6. Hypocretin measurement: shelf age of radioimmunoassay kit, but not freezer time, influences assay variability.

    Science.gov (United States)

    Keating, Glenda; Bliwise, Donald L; Saini, Prabhjyot; Rye, David B; Trotti, Lynn Marie

    2017-09-01

    The hypothalamic peptide hypocretin 1 (orexin A) may be assayed in cerebrospinal fluid to diagnose narcolepsy type 1. This testing is not commercially available, and factors contributing to assay variability have not previously been comprehensively explored. In the present study, cerebrospinal fluid hypocretin concentrations were determined in duplicate in 155 patient samples, across a range of sleep disorders. Intra-assay variability of these measures was analyzed. Inter-assay correlation between samples tested at Emory and at Stanford was high (r = 0.79, p hypocretin values, such that kits closer to expiration exhibit significantly more variability.

  7. Effects of estradiol and progesterone on the variability of the micronucleus assay

    International Nuclear Information System (INIS)

    Baeyens, Ans; Vandersickel, Veerle; Thierens, Hubert; Ridder, Leo De; Vral, Anne

    2005-01-01

    To investigate chromosomal radiosensitivity of lymphocytes the micronucleus (MN) assay has been used for many years. The results of these studies suggest the use of the MN assay as a biomarker for cancer predisposition. However, the MN assay has still some limitations associated with the reproducibility and sensitivity. Especially a high intra-individual variability has been observed. An explanation for this high intra-individual variability is not yet available. In literature it is suggested that the high variability among females is attributable to hormonal status. In this study we investigated if the high intra-individual variability in micronucleus formation in lymphocytes of females after in vitro exposure to ionising radiation is caused by variations in hormone levels of estradiol (E2) and progesterone (PROG). For this, the MN assay was performed on blood samples of 18 healthy women during 7 consecutive weeks while the estradiol and progesterone levels were determined at the same time. The MN assay was also examined in cultures of isolated blood lymphocytes with estradiol or progesterone levels added in vitro. The results demonstrated that estradiol and progesterone levels have no influence on the variations in radiation-induced MN yields observed in blood samples of healthy women. These conclusions were confirmed by the 'in vitro' experiments as no correlation between the MN yields and the concentrations of hormones (estradiol or progesterone) added in vitro to isolated lymphocytes cultures was observed

  8. Time dependent analysis of assay comparability: a novel approach to understand intra- and inter-site variability over time

    Science.gov (United States)

    Winiwarter, Susanne; Middleton, Brian; Jones, Barry; Courtney, Paul; Lindmark, Bo; Page, Ken M.; Clark, Alan; Landqvist, Claire

    2015-09-01

    We demonstrate here a novel use of statistical tools to study intra- and inter-site assay variability of five early drug metabolism and pharmacokinetics in vitro assays over time. Firstly, a tool for process control is presented. It shows the overall assay variability but allows also the following of changes due to assay adjustments and can additionally highlight other, potentially unexpected variations. Secondly, we define the minimum discriminatory difference/ratio to support projects to understand how experimental values measured at different sites at a given time can be compared. Such discriminatory values are calculated for 3 month periods and followed over time for each assay. Again assay modifications, especially assay harmonization efforts, can be noted. Both the process control tool and the variability estimates are based on the results of control compounds tested every time an assay is run. Variability estimates for a limited set of project compounds were computed as well and found to be comparable. This analysis reinforces the need to consider assay variability in decision making, compound ranking and in silico modeling.

  9. Implementation of dynamic cross-talk correction (DCTC) for MOX holdup assay measurements among multiple gloveboxes

    International Nuclear Information System (INIS)

    Nakamichi, Hideo; Nakamura, Hironobu; Mukai, Yasunobu; Kurita, Tsutomu; Beddingfield, David H.

    2012-01-01

    Plutonium holdup in gloveboxes (GBs) are measured by (passive neutron based NDA (HBAS) for the material control and accountancy (MC and A) at Plutonium Conversion Development Facility (PCDF). In the case that the GBs are installed close to one another, the cross-talk which means neutron double counting among GBs should be corrected properly. Though we used to use predetermined constants as the cross-talk correction, a new correction methodology for neutron cross-talk among the GBs with inventory changes is required for the improvement of MC and A. In order to address the issue of variable cross-talk contributions to holdup assay values, we applied a dynamic cross-talk correction (DCTC) method, based on the distributed source-term analysis approach, to obtain the actual doubles derived from the cross-talk between multiple GBs. As a result of introduction of DCTC for HBAS measurement, we could reduce source biases from the assay result by estimating the reliable doubles-counting derived from the cross-talk. Therefore, we could improve HBAS measurement uncertainty to a half of conventional system, and we are going to confirm the result. Since the DCTC methodology can be used to determine the cross-correlation among multiple inventories in small areas, it is expected that this methodology can be extended to the knowledge of safeguards by design. (author)

  10. Multiple variables data sets visualization in ROOT

    International Nuclear Information System (INIS)

    Couet, O

    2008-01-01

    The ROOT graphical framework provides support for many different functions including basic graphics, high-level visualization techniques, output on files, 3D viewing etc. They use well-known world standards to render graphics on screen, to produce high-quality output files, and to generate images for Web publishing. Many techniques allow visualization of all the basic ROOT data types, but the graphical framework was still a bit weak in the visualization of multiple variables data sets. This paper presents latest developments done in the ROOT framework to visualize multiple variables (>4) data sets

  11. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

    Science.gov (United States)

    Choi, Yong Seok; Lee, Kelvin H

    2016-03-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.

  12. Variables affecting viral plaque formation in microculture plaque assays using homologous antibody in a liquid overlay.

    Science.gov (United States)

    Randhawa, A S; Stanton, G J; Green, J A; Baron, S

    1977-05-01

    A liquid antibody microculture plaque assay and the variables that govern its effectiveness are described. The assay is based on the principle that low concentrations of homologous antibody can inhibit secondary plaque formation without inhibiting formation of primary plaques. Thus, clear plaques that followed a linear dose response were produced. The assay was found to be more rapid, less cumbersome, and less expensive than assays using agar overlays and larger tissue culture plates. It was reproducible, quantitative, and had about the same sensitivity as the agar overlay technique in measuring infectious coxsackievirus type B-3. It was more sensitive in assaying adenovirus type 3 and Western equine encephalomyelitis, vesicular stomatitis, Semliki forest, Sendai, Sindbis, and Newcastle disease viruses than were liquid, carboxymethylcellulose, and methylcellulose microculture plaque assays. The variables influencing sensitivity and accuracy, as determined by using coxsackievirus type B-3, were: (i) the inoculum volume of virus; (ii) the incubation period of virus; and (iii) the incubation temperature.

  13. VariableR Reclustering in Multiple Top Quark and W Boson Events

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, Jeremy [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-14

    VariableR jet reclustering is an innovative technique that allows for the reconstruction of boosted object over a wide range of kinematic regimes. Such capability enables the efficient identification of events with multiple boosted top quarks which is a typical signature for new physics processes such as the production of the supersymmetric partner of the gluon. In order to evaluate the performance of the algorithm, the VariableR reclustered jets are compared with fixed radius reclustered jets. The flexibility of the algorithm is tested by reconstructing both boosted top quarks and boosted W bosons. The VariableR reclustering method is found to be more efficient than the fixed radius algorithm at identifying top quarks and W bosons in events with four top quarks, therefore enhancing the sensitivity for gluino searches.

  14. Paper-Based Digital Microfluidic Chip for Multiple Electrochemical Assay Operated by a Wireless Portable Control System

    DEFF Research Database (Denmark)

    Ruecha, Nipapan; Lee, Jumi; Chae, Heedo

    2017-01-01

    for multiple analysis assays are fabricated by affordable printing techniques. For enhanced sensitivity of the sensor, the working electrode is modified through the electrochemical method, namely by reducing graphene with voltammetry and coating gold nanoparticles by amperometry. Detachable sensor and absorber...... designed portable power supply and wireless control system, the active paper-based chip platform can be utilized as an advanced point-of-care device for multiple assays in digital microfluidics....

  15. Variable precision rough set for multiple decision attribute analysis

    Institute of Scientific and Technical Information of China (English)

    Lai; Kin; Keung

    2008-01-01

    A variable precision rough set (VPRS) model is used to solve the multi-attribute decision analysis (MADA) problem with multiple conflicting decision attributes and multiple condition attributes. By introducing confidence measures and a β-reduct, the VPRS model can rationally solve the conflicting decision analysis problem with multiple decision attributes and multiple condition attributes. For illustration, a medical diagnosis example is utilized to show the feasibility of the VPRS model in solving the MADA...

  16. FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

    Energy Technology Data Exchange (ETDEWEB)

    Boumaaraf, Abdelâali, E-mail: aboumaaraf@yahoo.fr [Université Abbès Laghrour, Laboratoire des capteurs, Instrumentations et procédés (LCIP), Khenchela (Algeria); University of Farhat Abbas Setif1, Sétif, 19000 (Algeria); Mohamadi, Tayeb [University of Farhat Abbas Setif1, Sétif, 19000 (Algeria); Gourmat, Laïd [Université Abbès Laghrour, Khenchela, 40000 (Algeria)

    2016-07-25

    In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

  17. Multiple-source multiple-harmonic active vibration control of variable section cylindrical structures: A numerical study

    Science.gov (United States)

    Liu, Jinxin; Chen, Xuefeng; Gao, Jiawei; Zhang, Xingwu

    2016-12-01

    Air vehicles, space vehicles and underwater vehicles, the cabins of which can be viewed as variable section cylindrical structures, have multiple rotational vibration sources (e.g., engines, propellers, compressors and motors), making the spectrum of noise multiple-harmonic. The suppression of such noise has been a focus of interests in the field of active vibration control (AVC). In this paper, a multiple-source multiple-harmonic (MSMH) active vibration suppression algorithm with feed-forward structure is proposed based on reference amplitude rectification and conjugate gradient method (CGM). An AVC simulation scheme called finite element model in-loop simulation (FEMILS) is also proposed for rapid algorithm verification. Numerical studies of AVC are conducted on a variable section cylindrical structure based on the proposed MSMH algorithm and FEMILS scheme. It can be seen from the numerical studies that: (1) the proposed MSMH algorithm can individually suppress each component of the multiple-harmonic noise with an unified and improved convergence rate; (2) the FEMILS scheme is convenient and straightforward for multiple-source simulations with an acceptable loop time. Moreover, the simulations have similar procedure to real-life control and can be easily extended to physical model platform.

  18. Identification of Variable-Number Tandem-Repeat (VNTR) Sequences in Legionella pneumophila and Development of an Optimized Multiple-Locus VNTR Analysis Typing Scheme▿

    Science.gov (United States)

    Pourcel, Christine; Visca, Paolo; Afshar, Baharak; D'Arezzo, Silvia; Vergnaud, Gilles; Fry, Norman K.

    2007-01-01

    The utility of a genotypic typing assay for Legionella pneumophila was investigated. A multiple-locus variable number of tandem repeats (VNTR) analysis (MLVA) scheme using PCR and agarose gel electrophoresis is proposed based on eight minisatellite markers. Panels of well-characterized strains were examined in a multicenter analysis to validate the assay and to compare its performance to that of other genotyping assays. Excellent typeability, reproducibility, stability, and epidemiological concordance were observed. The MLVA type or profile is composed of a string of allele numbers, corresponding to the number of repeats at each VNTR locus, separated by commas, in a predetermined order. A database containing information from 99 L. pneumophila serogroup 1 strains and four strains of other serogroups and their MLVA profiles, which can be queried online, is available from http://bacterial-genotyping.igmors.u-psud.fr/. PMID:17251393

  19. Variability of assay methods for total and free PSA after WHO standardization.

    Science.gov (United States)

    Foj, L; Filella, X; Alcover, J; Augé, J M; Escudero, J M; Molina, R

    2014-03-01

    The variability of total PSA (tPSA) and free PSA (fPSA) results among commercial assays has been suggested to be decreased by calibration to World Health Organization (WHO) reference materials. To characterize the current situation, it is necessary to know its impact in the critical cutoffs used in clinical practice. In the present study, we tested 167 samples with tPSA concentrations of 0 to 20 μg/L using seven PSA and six fPSA commercial assays, including Access, ARCHITECT i2000, ADVIA Centaur XP, IMMULITE 2000, Elecsys, and Lumipulse G1200, in which we only measured tPSA. tPSA and fPSA were measured in Access using the Hybritech and WHO calibrators. Passing-Bablok analysis was performed for PSA, and percentage of fPSA with the Hybritech-calibrated access comparison assay. For tPSA, relative differences were more than 10 % at 0.2 μg/L for ARCHITECT i2000, and at a critical concentration of 3, 4, and 10 μg/L, the relative difference was exceeded by ADVIA Centaur XP and WHO-calibrated Access. For percent fPSA, at a critical concentration of 10 %, the 10 % relative difference limit was exceeded by IMMULITE 2000 assay. At a critical concentration of 20 and 25 %, ADVIA Centaur XP, ARCHITECT i2000, and IMMULITE 2000 assays exceeded the 10 % relative difference limit. We have shown significant discordances between assays included in this study despite advances in standardization conducted in the last years. Further harmonization efforts are required in order to obtain a complete clinical concordance.

  20. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    Science.gov (United States)

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  1. Temporal Assessment of the Impact of Exposure to Cow Feces in Two Watersheds by Multiple Host-Specific PCR Assays

    Science.gov (United States)

    Exposure to feces in two watersheds with different management histories was assessed by tracking cattle feces bacterial populations using multiple host-specific PCR assays. In addition, environmental factors affecting the occurrence of these markers were identified. Each assay wa...

  2. Toxicity screening of soils from different mine areas—A contribution to track the sensitivity and variability of Arthrobacter globiformis assay

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Catarina R., E-mail: crmarques@ua.pt [Departamento de Biologia and CESAM (Centro de Estudos do Ambiente e do Mar), Universidade de Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro (Portugal); Caetano, Ana L. [Departamento de Biologia and CESAM (Centro de Estudos do Ambiente e do Mar), Universidade de Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro (Portugal); Haller, Andreas [ECT Oekotoxikologie GmbH, Böttgerstraße 2–14, D-65439 Flörsheim a. M. (Germany); Gonçalves, Fernando [Departamento de Biologia and CESAM (Centro de Estudos do Ambiente e do Mar), Universidade de Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro (Portugal); Pereira, Ruth [Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007 Porto (Portugal); Interdisciplinary Centre of Marine and Environmental Research (CIIMAR/CIMAR), Universidade do Porto, Rua dos Bragas 289, P 4050-123 Porto (Portugal); Römbke, Jörg [ECT Oekotoxikologie GmbH, Böttgerstraße 2–14, D-65439 Flörsheim a. M. (Germany)

    2014-06-01

    Highlights: • The assay gave rapid and feasible discrimination of toxic soils to A. globiformis. • Sensitive and low variability response to soils from different regions. • Soil properties may interfere with metal toxicity and fluorescence measurements. • Proposal of a toxicity threshold for the contact assay regarding soils. • A. globiformis assay should be included in the Tier I of risk assessment frameworks. - Abstract: This study used the Arthrobacter globiformis solid-contact test for assessing the quality of soils collected in areas subjected to past and present mine activities in Europe (uranium mine, Portugal) and North Africa (phosphogypsum pile, Tunisia; iron mine, Morocco). As to discriminate the influence of soils natural variability from the effect of contaminants, toxicity thresholds were derived for this test, based on the dataset of each study area. Furthermore, the test sensitivity and variability was also evaluated. As a result, soils that inhibited A. globiformis dehydrogenase activity above 45% or 50% relatively to the control, were considered to be toxic. Despite the soil metal content determined, the properties of soils seemed to influence dehydrogenase activity. Overall, the contact test provided a coherent outcome comparing to other more time-consuming and effort-demanding ecotoxicological assays. Our results strengthened the feasibility and ecological relevance of this assay, which variability was quite reduced hence suggesting its potential integration within the test battery of tier 1 of soil risk assessment schemes.

  3. Toxicity screening of soils from different mine areas—A contribution to track the sensitivity and variability of Arthrobacter globiformis assay

    International Nuclear Information System (INIS)

    Marques, Catarina R.; Caetano, Ana L.; Haller, Andreas; Gonçalves, Fernando; Pereira, Ruth; Römbke, Jörg

    2014-01-01

    Highlights: • The assay gave rapid and feasible discrimination of toxic soils to A. globiformis. • Sensitive and low variability response to soils from different regions. • Soil properties may interfere with metal toxicity and fluorescence measurements. • Proposal of a toxicity threshold for the contact assay regarding soils. • A. globiformis assay should be included in the Tier I of risk assessment frameworks. - Abstract: This study used the Arthrobacter globiformis solid-contact test for assessing the quality of soils collected in areas subjected to past and present mine activities in Europe (uranium mine, Portugal) and North Africa (phosphogypsum pile, Tunisia; iron mine, Morocco). As to discriminate the influence of soils natural variability from the effect of contaminants, toxicity thresholds were derived for this test, based on the dataset of each study area. Furthermore, the test sensitivity and variability was also evaluated. As a result, soils that inhibited A. globiformis dehydrogenase activity above 45% or 50% relatively to the control, were considered to be toxic. Despite the soil metal content determined, the properties of soils seemed to influence dehydrogenase activity. Overall, the contact test provided a coherent outcome comparing to other more time-consuming and effort-demanding ecotoxicological assays. Our results strengthened the feasibility and ecological relevance of this assay, which variability was quite reduced hence suggesting its potential integration within the test battery of tier 1 of soil risk assessment schemes

  4. Passive assay of plutonium metal plates using a fast-neutron multiplicity counter

    Energy Technology Data Exchange (ETDEWEB)

    Di Fulvio, A., E-mail: difulvio@umich.edu [Department of Nuclear Engineering & Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Shin, T.H.; Jordan, T.; Sosa, C.; Ruch, M.L.; Clarke, S.D. [Department of Nuclear Engineering & Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Chichester, D.L. [Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Pozzi, S.A. [Department of Nuclear Engineering & Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States)

    2017-05-21

    We developed a fast-neutron multiplicity counter based on organic scintillators (EJ-309 liquid and stilbene). The system detects correlated photon and neutron multiplets emitted by fission reactions, within a gate time of tens of nanoseconds. The system was used at Idaho National Laboratory to assay a variety of plutonium metal plates. A coincidence counting strategy was used to quantify the {sup 240}Pu effective mass of the samples. Coincident neutrons, detected within a 40-ns coincidence window, show a monotonic trend, increasing with the {sup 240}Pu-effective mass (in this work, we tested the 0.005–0.5 kg range). After calibration, the system estimated the {sup 240}Pu effective mass of an unknown sample ({sup 240}Pu{sub eff} >50 g) with an uncertainty lower than 1% in a 4-min assay time.

  5. Comparison of multiple assays for detecting human antibodies directed against antigens on normal and malignant tissue culture cells

    International Nuclear Information System (INIS)

    Rosenberg, S.A.; Schwarz, S.; Anding, H.; Hyatt, C.; Williams, G.M.; Johns Hopkins Univ., Baltimore, Md.

    1977-01-01

    Four separate assays of human antibody reactivity to four separate normal and malignant human tissue culture cells lines from two patients have been evaluated using a single highly-reactive allogeneic serum. The visual end-point cytolysis assay and the chromium-51 release assay were equally sensitive in measuring complement mediated antibody cytotoxicity and both were far more sensitive than a trypan blue dye exclusion assay. The assay of antibody reactivity by hemadsorption technique was about 10 times more sensitive than any of the cytotoxicity assays. This latter assay measures only IgG antibody however. These assays showed that cell lines from different patients may differ greatly in 'reactivity' to an allogeneic serum and emphasized the importance of utilizing tumor and normal cells from the same patient when using tissue culture cells to search for tumor specific reactivity. These observations emphasize the importance of utilizing multiple assays against paired normal and malignant cells from the same patient to be certain of the specificity and magnitude of the measured antibody

  6. Identification of Variable-Number Tandem-Repeat (VNTR) Sequences in Acinetobacter baumannii and Interlaboratory Validation of an Optimized Multiple-Locus VNTR Analysis Typing Scheme▿†

    Science.gov (United States)

    Pourcel, Christine; Minandri, Fabrizia; Hauck, Yolande; D'Arezzo, Silvia; Imperi, Francesco; Vergnaud, Gilles; Visca, Paolo

    2011-01-01

    Acinetobacter baumannii is an important opportunistic pathogen responsible for nosocomial outbreaks, mostly occurring in intensive care units. Due to the multiplicity of infection sources, reliable molecular fingerprinting techniques are needed to establish epidemiological correlations among A. baumannii isolates. Multiple-locus variable-number tandem-repeat analysis (MLVA) has proven to be a fast, reliable, and cost-effective typing method for several bacterial species. In this study, an MLVA assay compatible with simple PCR- and agarose gel-based electrophoresis steps as well as with high-throughput automated methods was developed for A. baumannii typing. Preliminarily, 10 potential polymorphic variable-number tandem repeats (VNTRs) were identified upon bioinformatic screening of six annotated genome sequences of A. baumannii. A collection of 7 reference strains plus 18 well-characterized isolates, including unique types and representatives of the three international A. baumannii lineages, was then evaluated in a two-center study aimed at validating the MLVA assay and comparing it with other genotyping assays, namely, macrorestriction analysis with pulsed-field gel electrophoresis (PFGE) and PCR-based sequence group (SG) profiling. The results showed that MLVA can discriminate between isolates with identical PFGE types and SG profiles. A panel of eight VNTR markers was selected, all showing the ability to be amplified and good amounts of polymorphism in the majority of strains. Independently generated MLVA profiles, composed of an ordered string of allele numbers corresponding to the number of repeats at each VNTR locus, were concordant between centers. Typeability, reproducibility, stability, discriminatory power, and epidemiological concordance were excellent. A database containing information and MLVA profiles for several A. baumannii strains is available from http://mlva.u-psud.fr/. PMID:21147956

  7. Multiple Imputation of Predictor Variables Using Generalized Additive Models

    NARCIS (Netherlands)

    de Jong, Roel; van Buuren, Stef; Spiess, Martin

    2016-01-01

    The sensitivity of multiple imputation methods to deviations from their distributional assumptions is investigated using simulations, where the parameters of scientific interest are the coefficients of a linear regression model, and values in predictor variables are missing at random. The

  8. Multiple and variable NHEJ-like genes are involved in resistance to DNA damage in Streptomyces ambofaciens

    Directory of Open Access Journals (Sweden)

    Grégory Hoff

    2016-11-01

    Full Text Available Non homologous end-joining (NHEJ is a double strand break (DSB repair pathway which does not require any homologous template and can ligate two DNA ends together. The basic bacterial NHEJ machinery involves two partners: the Ku protein, a DNA end binding protein for DSB recognition and the multifunctional LigD protein composed a ligase, a nuclease and a polymerase domain, for end processing and ligation of the broken ends. In silico analyses performed in the 38 sequenced genomes of Streptomyces species revealed the existence of a large panel of NHEJ-like genes. Indeed, ku genes or ligD domain homologues are scattered throughout the genome in multiple copies and can be distinguished in two categories: the core NHEJ gene set constituted of conserved loci and the variable NHEJ gene set constituted of NHEJ-like genes present in only a part of the species. In Streptomyces ambofaciens ATCC 23877, not only the deletion of core genes but also that of variable genes led to an increased sensitivity to DNA damage induced by electron beam irradiation. Multiple mutants of ku, ligase or polymerase encoding genes showed an aggravated phenotype compared to single mutants. Biochemical assays revealed the ability of Ku-like proteins to protect and to stimulate ligation of DNA ends. RT-qPCR and GFP fusion experiments suggested that ku-like genes show a growth phase dependent expression profile consistent with their involvement in DNA repair during spores formation and/or germination.

  9. Non-destructive assay of fissile materials by detection and multiplicity analysis of spontaneous neutrons

    International Nuclear Information System (INIS)

    Prosdocimi, A.

    1979-01-01

    A method for determining the absolute reaction rate of nuclear events giving rise to neutron emission, according to their neutron multiplicity, is proposed. A typical application is the measurement of the (α, n) and spontaneous fission rates in a fissile material sample, particularly of Pu oxide composition. An analysis of random and correlated neutron pulses is carried out on the basis of sequential order without requiring any time interval analysis, then the primary nuclear events are sorted versus their neutron multiplicity. Suitable theoretical relationships enable to derive the absolute (α, n) and SF reaction rates when the physical parameters of the neutron detector and the multiplicity spectrumm of pulses are known. A typical device is described and the results of experiments leading to Pu-239 and Pu-240 assay are given

  10. Variable Speed Wind Turbine Based on Multiple Generators Drive-Train Configuration

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2010-01-01

    A variable speed wind turbine is presented in this paper, where multiple permanent magnet synchronous generators (MPMSGs) drive-train configuration is employed in the wind turbine. A cascaded multilevel converter interface based on the MPMSGs is developed to synthesize a desired high ac sinusoidal...... output voltage, which could be directly connected to the grids. What is more, such arrangement has been made so that the output ac voltage having a selected phase angle difference among the stator windings of multiple generators. A phase angle shift strategy is proposed in this paper, which effectively...... reduce the fluctuation of the electromagnetic torque sum and results in a good performance for the MPMSGs structure. The simulation study is conducted using PSCAD/EMTDC, and the results verify the feasibility of this variable speed wind turbine based on multiple generators drive-train configuration....

  11. The narrow therapeutic window of glycated hemoglobin and assay variability.

    Science.gov (United States)

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  12. Evaluation of an ex vivo murine local lymph node assay: multiple endpoint comparison.

    Science.gov (United States)

    Piccotti, Joseph R; Knight, Stephanie A; Gillhouse, Kimberly; Lagattuta, Mark S; Bleavins, Michael R

    2006-01-01

    The local lymph node assay (LLNA) is used to assess the skin sensitization potential of chemicals. In the standard assay, mice are treated topically on the dorsum of both ears with test substance for 3 days. Following 2 days of rest, the initiation of the hypersensitivity response is evaluated by injecting (3)H-thymidine into a tail vein, and then measuring the levels of radioisotope incorporated into the DNA of lymph node cells draining the ears. In the current study, BALB/c mice were treated with the contact sensitizers hexylcinnamic aldehyde (HCA) and oxazolone, and the nonsensitizer methyl salicylate. The proliferative response of lymph node cells was evaluated in an ex vivo assay, in which isolated cells were cultured in vitro with (3)H-thymidine. Treatment of mice with HCA at 5-50% resulted in concentration-related increases in (3)H-thymidine incorporation, with stimulation indices ranging from 3 to 14. Low animal-to-animal variability was seen in three replicate assays testing HCA at 25%. As anticipated, the proliferative response induced by the potent sensitizer oxazolone at 0.25% was greater than HCA at all concentrations tested. Stimulation indices of 1.5 and 3 were seen in two independent experiments with methyl salicylate. These equivocal findings were likely due to the irritancy properties of the compound. Importantly, measuring ex vivo (3)H-thymidine incorporation was more sensitive than evaluating lymph node weight and cellularity, and in vitro bromodeoxyuridine incorporation. Furthermore, the results of the ex vivo LLNA were comparable to the standard assay. This study provided evidence that supports the use of an ex vivo LLNA for hazard assessment of contact hypersensitivity. Copyright 2006 John Wiley & Sons, Ltd.

  13. Data analysis as a source of variability of the HLA-peptide multimer assay

    DEFF Research Database (Denmark)

    Gouttefangeas, Cécile; Chan, Cliburn; Attig, Sebastian

    2015-01-01

    by laboratories performing ex vivo T cell immune monitoring. In particular, analysis currently relies on a manual, step-by-step strategy employing serial gating decisions based on visual inspection of one- or two-dimensional plots. It is therefore operator dependent and subjective. In the context of continuing......Multiparameter flow cytometry is an indispensable method for assessing antigen-specific T cells in basic research and cancer immunotherapy. Proficiency panels have shown that cell sample processing, test protocols and data analysis may all contribute to the variability of the results obtained...... efforts to support inter-laboratory T cell assay harmonization, the CIMT Immunoguiding Program organized its third proficiency panel dedicated to the detection of antigen-specific CD8(+) T cells by HLA-peptide multimer staining. We first assessed the contribution of manual data analysis to the variability...

  14. Interpreting Multiple Linear Regression: A Guidebook of Variable Importance

    Science.gov (United States)

    Nathans, Laura L.; Oswald, Frederick L.; Nimon, Kim

    2012-01-01

    Multiple regression (MR) analyses are commonly employed in social science fields. It is also common for interpretation of results to typically reflect overreliance on beta weights, often resulting in very limited interpretations of variable importance. It appears that few researchers employ other methods to obtain a fuller understanding of what…

  15. Micro-macro multilevel latent class models with multiple discrete individual-level variables

    NARCIS (Netherlands)

    Bennink, M.; Croon, M.A.; Kroon, B.; Vermunt, J.K.

    2016-01-01

    An existing micro-macro method for a single individual-level variable is extended to the multivariate situation by presenting two multilevel latent class models in which multiple discrete individual-level variables are used to explain a group-level outcome. As in the univariate case, the

  16. Feasibility Study of Neutron Multiplicity Assay for a Heterogeneous Sludge Sample containing Na, Pu and other Impurities

    International Nuclear Information System (INIS)

    Nakamura, H.; Nakamichi, H.; Mukai, Y.; Yoshimoto, K.; Beddingfield, D.H.

    2010-01-01

    To reduce radioactivity of liquid waste generated at PCDF, a neutralization precipitation processes of radioactive nuclides by sodium hydroxide is used. We call the precipitate a 'sludge' after calcination. Pu mass in the sludge is normally determined by sampling and DA within the required uncertainty on DIQ. Annual yield of the mass is small but it accumulates and reaches to a few kilograms, so it is declared as retained waste and verified at PIV. A HM-5-based verification is applied for sludge verification. The sludge contains many chemical components. For example, Pu (-10wt%), U, Am, SUS components, halogens, NaNO 3 (main component), residual NaOH, and moisture. They are mixed together as an impure heterogeneous sludge sample. As a result, there is a large uncertainty in the sampling and DA that is currently used at PCDF. In order to improve the material accounting, we performed a feasibility study using neutron multiplicity assay for impure sludge samples. We have measured selected sludge samples using a multiplicity counter which is called FCAS (Fast Carton Assay System) which was designed by JAEA and Canberra. The PCDF sludge materials fall into the category of 'difficult to measure' because of the high levels of impurities, high alpha values and somewhat small Pu mass. For the sludge measurements, it was confirmed that good consistency between Pu mass in a pure sludge standard (PuO 2 -Na 2 U 2 O 7 , alpha=7) and the DA could be obtained. For unknown samples, using 14-hour measurements, we could obtain quite low statistical uncertainty on Doubles (-1%) and Triples (-10%) count rate although the alpha value was extremely high (15-25) and FCAS efficiency was relatively low (40%) for typical multiplicity counters. Despite the detector efficiency challenges and the material challenges (high alpha, low Pu mass, heterogeneous matrix), we have been able to obtain assay results that greatly exceed the accountancy requirements for retained waste materials. We have

  17. Identification of Variable-Number Tandem-Repeat (VNTR) Sequences in Acinetobacter pittii and Development of an Optimized Multiple-Locus VNTR Analysis Typing Scheme.

    Science.gov (United States)

    Hu, Yuan; Li, Bo Qing; Jin, Da Zhi; He, Li Hua; Tao, Xiao Xia; Zhang, Jian Zhong

    2015-12-01

    To develop a multiple-locus variable-number tandem-repeat (VNTR) analysis (MLVA) assay for Acinetobacter pittii typing. Polymorphic VNTRs were searched by Tandem Repeats Finder. The distribution and polymorphism of each VNTR locus were analyzed in all the A. pittii genomes deposited in the NCBI genome database by BLAST and were evaluated with a collection of 20 well-characterized clinical A. pittii strains and one reference strain. The MLVA assay was compared with pulsed-field gel electrophoresis (PFGE) for discriminating A. pittii isolates. Ten VNTR loci were identified upon bioinformatic screening of A. pittii genomes, but only five of them showed full amplifiability and good polymorphism. Therefore, an MLVA assay composed of five VNTR loci was developed. The typeability, reproducibility, stability, discriminatory power, and epidemiological concordance were excellent. Compared with PFGE, the new optimized MLVA typing scheme provided the same and even greater discrimination. Compared with PFGE, MLVA typing is a faster and more standardized alternative for studying the genetic relatedness of A. pittii isolates in disease surveillance and outbreak investigation. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  18. Chromosomal radiosensitivity: a study of the chromosomal G2 assay in human blood lymphocytes indicating significant inter-individual variability

    International Nuclear Information System (INIS)

    Smart, V.; Curwen, G.B.; Whitehouse, C.A.; Edwards, A.; Tawn, E.J.

    2003-01-01

    The G 2 chromosomal radiosensitivity assay is a technically demanding assay. To ensure that it is reproducible in our laboratory, we have examined the effects of storage and culture conditions by applying the assay to a group of healthy controls and determined the extent of intra- and inter-individual variations. Nineteen different individuals provided one or more blood samples resulting in a total of 57 successful tests. Multiple cultures from a single blood sample showed no statistically significant difference in the number of chromatid type aberrations between cultures. A 24 h delay prior to culturing the lymphocytes did not significantly affect the induced G 2 score. Intra-individual variation was not statistically significant in seven out of nine individuals. Inter-individual variation was highly statistically significant (P<0.001), indicating that there is a real difference between individuals in the response to radiation using this assay

  19. Development of multiple strain competitive index assays for Listeria monocytogenes using pIMC; a new site-specific integrative vector

    Directory of Open Access Journals (Sweden)

    Cronin Michael

    2008-06-01

    Full Text Available Abstract Background The foodborne, gram-positive pathogen, Listeria monocytogenes, is capable of causing lethal infections in compromised individuals. In the post genomic era of L. monocytogenes research, techniques are required to identify and validate genes involved in the pathogenicity and environmental biology of the organism. The aim here was to develop a widely applicable method to tag L. monocytogenes strains, with a particular emphasis on the development of multiple strain competitive index assays. Results We have constructed a new site-specific integrative vector, pIMC, based on pPL2, for the selection of L. monocytogenes from complex samples. The pIMC vector was further modified through the incorporation of IPTG inducible markers (antibiotic and phenotypic to produce a suite of four vectors which allowed the discrimination of multiple strains from a single sample. We were able to perform murine infection studies with up to four EGDe isolates within a single mouse and showed that the tags did not impact upon growth rate or virulence. The system also allowed the identification of subtle differences in virulence between strains of L. monocytogenes commonly used in laboratory studies. Conclusion This study has developed a competitive index assay that can be broadly applied to all L. monocytogenes strains. Improved statistical robustness of the data was observed, resulting in fewer mice being required for virulence assays. The competitive index assays provide a powerful method to analyse the virulence or fitness of L. monocytogenes in complex biological samples.

  20. Rapid multiple immunoenzyme assay of mycotoxins.

    Science.gov (United States)

    Urusov, Alexandr E; Zherdev, Anatoly V; Petrakova, Alina V; Sadykhov, Elchin G; Koroleva, Olga V; Dzantiev, Boris B

    2015-01-27

    Mycotoxins are low molecular weight fungal metabolites that pose a threat as toxic contaminants of food products, thereby necessitating their effective monitoring and control. Microplate ELISA can be used for this purpose, but this method is characteristically time consuming, with a duration extending to several hours. This report proposes a variant of the ELISA method for the detection and quantification of three mycotoxins, ochratoxin A, aflatoxin B1 and zearalenone, in the kinetic regime. The main requirement for the proposed kinetic protocol was to provide a rapid method that combined sensitivity and accuracy. The use of biotin with an extended spacer together with a streptavidin-polyperoxidase conjugate provided high signal levels, despite these interactions occurring under non-equilibrium conditions. Duration of the individual mycotoxin assays was 20 min, whereas the analysis of all three mycotoxins in parallel reached a maximum duration of 25 min. Recovery of at least 95% mycotoxins in water-organic extracts was shown. The developed assays were successfully validated using poultry processing products and corn samples spiked with known quantities of mycotoxins. The detection limits for aflatoxin B1, ochratoxin A and zearalenone in these substances were 0.24, 1.2 and 3 ng/g, respectively.

  1. Multiple-endpoint assay provides a detailed mechanistic view of responses to herbicide exposure in Chlamydomonas reinhardtii

    International Nuclear Information System (INIS)

    Nestler, Holger; Groh, Ksenia J.; Schönenberger, René; Behra, Renata; Schirmer, Kristin; Eggen, Rik I.L.; Suter, Marc J.-F.

    2012-01-01

    The release of herbicides into the aquatic environment raises concerns about potential detrimental effects on ecologically important non-target species, such as unicellular algae, necessitating ecotoxicological risk assessment. Algal toxicity tests based on growth, a commonly assessed endpoint, are integrative, and hence do not provide information about underlying toxic mechanisms and effects. This limitation may be overcome by measuring more specific biochemical and physiological endpoints. In the present work, we developed and applied a novel multiple-endpoint assay, and analyzed the effects of the herbicides paraquat, diuron and norflurazon, each representing a specific mechanism of toxic action, on the single celled green alga Chlamydomonas reinhardtii. The endpoints added to assessment of growth were pigment content, maximum and effective photosystem II quantum yield, ATP content, esterase and oxidative activity. All parameters were measured at 2, 6 and 24 h of exposure, except for growth and pigment content, which were determined after 6 and 24 h only. Effective concentrations causing 50% of response (EC50s) and lowest observable effect concentrations (LOECs) were determined for all endpoints and exposure durations where possible. The assay provided a detailed picture of the concentration- and time-dependent development of effects elicited by the analyzed herbicides, thus improving the understanding of the underlying toxic mechanisms. Furthermore, the response patterns were unique to the respective herbicide and reflected the different mechanisms of toxicity. The comparison of the endpoint responses and sensitivities revealed that several physiological and biochemical parameters reacted earlier or stronger to disturbances than growth. Overall, the presented multiple-endpoint assay constitutes a promising basis for investigating stressor and toxicant effects in green algae.

  2. Multiple-endpoint assay provides a detailed mechanistic view of responses to herbicide exposure in Chlamydomonas reinhardtii

    Energy Technology Data Exchange (ETDEWEB)

    Nestler, Holger [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); Groh, Ksenia J.; Schoenenberger, Rene; Behra, Renata [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); Schirmer, Kristin [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); EPF Lausanne, School of Architecture, Civil and Environmental Engineering, 1015 Lausanne (Switzerland); Eggen, Rik I.L. [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland); Suter, Marc J.-F., E-mail: suter@eawag.ch [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600 Duebendorf (Switzerland); ETH Zurich, Swiss Federal Institute of Technology, Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092 Zurich (Switzerland)

    2012-04-15

    The release of herbicides into the aquatic environment raises concerns about potential detrimental effects on ecologically important non-target species, such as unicellular algae, necessitating ecotoxicological risk assessment. Algal toxicity tests based on growth, a commonly assessed endpoint, are integrative, and hence do not provide information about underlying toxic mechanisms and effects. This limitation may be overcome by measuring more specific biochemical and physiological endpoints. In the present work, we developed and applied a novel multiple-endpoint assay, and analyzed the effects of the herbicides paraquat, diuron and norflurazon, each representing a specific mechanism of toxic action, on the single celled green alga Chlamydomonas reinhardtii. The endpoints added to assessment of growth were pigment content, maximum and effective photosystem II quantum yield, ATP content, esterase and oxidative activity. All parameters were measured at 2, 6 and 24 h of exposure, except for growth and pigment content, which were determined after 6 and 24 h only. Effective concentrations causing 50% of response (EC50s) and lowest observable effect concentrations (LOECs) were determined for all endpoints and exposure durations where possible. The assay provided a detailed picture of the concentration- and time-dependent development of effects elicited by the analyzed herbicides, thus improving the understanding of the underlying toxic mechanisms. Furthermore, the response patterns were unique to the respective herbicide and reflected the different mechanisms of toxicity. The comparison of the endpoint responses and sensitivities revealed that several physiological and biochemical parameters reacted earlier or stronger to disturbances than growth. Overall, the presented multiple-endpoint assay constitutes a promising basis for investigating stressor and toxicant effects in green algae.

  3. Multiple-endpoints gene alteration-based (MEGA) assay: A toxicogenomics approach for water quality assessment of wastewater effluents.

    Science.gov (United States)

    Fukushima, Toshikazu; Hara-Yamamura, Hiroe; Nakashima, Koji; Tan, Lea Chua; Okabe, Satoshi

    2017-12-01

    Wastewater effluents contain a significant number of toxic contaminants, which, even at low concentrations, display a wide variety of toxic actions. In this study, we developed a multiple-endpoints gene alteration-based (MEGA) assay, a real-time PCR-based transcriptomic analysis, to assess the water quality of wastewater effluents for human health risk assessment and management. Twenty-one genes from the human hepatoblastoma cell line (HepG2), covering the basic health-relevant stress responses such as response to xenobiotics, genotoxicity, and cytotoxicity, were selected and incorporated into the MEGA assay. The genes related to the p53-mediated DNA damage response and cytochrome P450 were selected as markers for genotoxicity and response to xenobiotics, respectively. Additionally, the genes that were dose-dependently regulated by exposure to the wastewater effluents were chosen as markers for cytotoxicity. The alterations in the expression of an individual gene, induced by exposure to the wastewater effluents, were evaluated by real-time PCR and the results were validated by genotoxicity (e.g., comet assay) and cell-based cytotoxicity tests. In summary, the MEGA assay is a real-time PCR-based assay that targets cellular responses to contaminants present in wastewater effluents at the transcriptional level; it is rapid, cost-effective, and high-throughput and can thus complement any chemical analysis for water quality assessment and management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Rapid Multiple Immunoenzyme Assay of Mycotoxins

    Directory of Open Access Journals (Sweden)

    Alexandr E. Urusov

    2015-01-01

    Full Text Available Mycotoxins are low molecular weight fungal metabolites that pose a threat as toxic contaminants of food products, thereby necessitating their effective monitoring and control. Microplate ELISA can be used for this purpose, but this method is characteristically time consuming, with a duration extending to several hours. This report proposes a variant of the ELISA method for the detection and quantification of three mycotoxins, ochratoxin A, aflatoxin B1 and zearalenone, in the kinetic regime. The main requirement for the proposed kinetic protocol was to provide a rapid method that combined sensitivity and accuracy. The use of biotin with an extended spacer together with a streptavidin–polyperoxidase conjugate provided high signal levels, despite these interactions occurring under non-equilibrium conditions. Duration of the individual mycotoxin assays was 20 min, whereas the analysis of all three mycotoxins in parallel reached a maximum duration of 25 min. Recovery of at least 95% mycotoxins in water-organic extracts was shown. The developed assays were successfully validated using poultry processing products and corn samples spiked with known quantities of mycotoxins. The detection limits for aflatoxin B1, ochratoxin A and zearalenone in these substances were 0.24, 1.2 and 3 ng/g, respectively.

  5. Clinical value of assays of multiple serum tumor markers in conjunction with 18F-FDG SPECT for discriminating malignant from benign lung disorders

    International Nuclear Information System (INIS)

    Zhang Chunyan; Wang Linglong; Tu Liping; Yu Yuefang; Zhu Weijie; Cai Ao; Gao Shuxing

    2006-01-01

    Objective: To evaluate the clinical value of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders. Methods: A total of 62 patients with malignant and benign lung diseases un- derwent 18 F-FDG SPECT examination and tests for serum tumor markers CEA, CA50, CA199 and CA242, alone or combined. The sensitivity, specificity, accuracy of these tests were examined. Results: The sensitivity, specificity accuracy of 18 F-FDG SPECT for the diagnosis of malignant lung tumors were 85.7 (30/35), 59.3 (16/27) and 74.2(46/62) respectively, those of each of serum CEA, CA199, CA50, CA242 levels in diagnosing malignant lung tumors were 22.9(8/35), 92.6(25/27), 59.7(33/62), 14.3(5/35), 100(27/27), 51.6 (32/62), 34.3 (12/35), 85.2 (23/27), 56.5 (35/62), 28.6 (10/35), 85.2 (23/27) and 53.2 (33/62) respectively, those of assays of multiple serum tumor markers for diagnosis of malignant lung tumors were 85.7 (30/35), 85.2 (23/27) and 85.5 (53/62) respectively, those of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung nodules were 88.6(31/35), 85.2(23/27) and 87.1 (54/62) respectively. Conclusion: Assays of multiple serum tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders can yield higher sensitivity, specialty and accuracy, making a significant contribution to clinical application. (authors)

  6. Auxiliary variables in multiple imputation in regression with missing X: a warning against including too many in small sample research

    Directory of Open Access Journals (Sweden)

    Hardt Jochen

    2012-12-01

    Full Text Available Abstract Background Multiple imputation is becoming increasingly popular. Theoretical considerations as well as simulation studies have shown that the inclusion of auxiliary variables is generally of benefit. Methods A simulation study of a linear regression with a response Y and two predictors X1 and X2 was performed on data with n = 50, 100 and 200 using complete cases or multiple imputation with 0, 10, 20, 40 and 80 auxiliary variables. Mechanisms of missingness were either 100% MCAR or 50% MAR + 50% MCAR. Auxiliary variables had low (r=.10 vs. moderate correlations (r=.50 with X’s and Y. Results The inclusion of auxiliary variables can improve a multiple imputation model. However, inclusion of too many variables leads to downward bias of regression coefficients and decreases precision. When the correlations are low, inclusion of auxiliary variables is not useful. Conclusion More research on auxiliary variables in multiple imputation should be performed. A preliminary rule of thumb could be that the ratio of variables to cases with complete data should not go below 1 : 3.

  7. Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses.

    Science.gov (United States)

    Almeida, Coral-Ann M; Roberts, Steven G; Laird, Rebecca; McKinnon, Elizabeth; Ahmed, Imran; Pfafferott, Katja; Turley, Joanne; Keane, Niamh M; Lucas, Andrew; Rushton, Ben; Chopra, Abha; Mallal, Simon; John, Mina

    2009-05-15

    The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV, EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, pautomated system compared favourably with the manual ELISpot and further ensured electronic tracking, increased through-put and reduced turnaround time.

  8. A study of the effect of measurement error in predictor variables in nondestructive assay

    International Nuclear Information System (INIS)

    Burr, Tom L.; Knepper, Paula L.

    2000-01-01

    It is not widely known that ordinary least squares estimates exhibit bias if there are errors in the predictor variables. For example, enrichment measurements are often fit to two predictors: Poisson-distributed count rates in the region of interest and in the background. Both count rates have at least random variation due to counting statistics. Therefore, the parameter estimates will be biased. In this case, the effect of bias is a minor issue because there is almost no interest in the parameters themselves. Instead, the parameters will be used to convert count rates into estimated enrichment. In other cases, this bias source is potentially more important. For example, in tomographic gamma scanning, there is an emission stage which depends on predictors (the 'system matrix') that are estimated with error during the transmission stage. In this paper, we provide background information for the impact and treatment of errors in predictors, present results of candidate methods of compensating for the effect, review some of the nondestructive assay situations where errors in predictors occurs, and provide guidance for when errors in predictors should be considered in nondestructive assay

  9. Sample preparation composite and replicate strategy case studies for assay of solid oral drug products.

    Science.gov (United States)

    Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei

    2017-11-30

    Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A Multiplexed Assay That Monitors Effects of Multiple Compound Treatment Times Reveals Candidate Immune-Enhancing Compounds.

    Science.gov (United States)

    Zhao, Ziyan; Henowitz, Liza; Zweifach, Adam

    2018-05-01

    We previously developed a flow cytometry assay that monitored lytic granule exocytosis in cytotoxic T lymphocytes stimulated by contacting beads coated with activating anti-CD3 antibodies. That assay was multiplexed in that responses of cells that did or did not receive the activating stimulus were distinguished via changes in light scatter accompanying binding of cells to beads, allowing us to discriminate compounds that activate responses on their own from compounds that enhance responses in cells that received the activating stimulus, all within a single sample. Here we add a second dimension of multiplexing by developing means to assess in a single sample the effects of treating cells with test compounds for different times. Bar-coding cells before adding them to test wells lets us determine compound treatment time while also monitoring activation status and response amplitude at the point of interrogation. This multiplexed assay is suitable for screening 96-well plates. We used it to screen compounds from the National Cancer Institute, identifying several compounds that enhance anti-LAMP1 responses. Multiple-treatment-time (MTT) screening enabled by bar-coding and read via high-throughput flow cytometry may be a generally useful method for facilitating the discovery of compounds of interest.

  11. A novel multiple locus variable number of tandem repeat (VNTR) analysis (MLVA) method for Propionibacterium acnes.

    Science.gov (United States)

    Hauck, Yolande; Soler, Charles; Gérôme, Patrick; Vong, Rithy; Macnab, Christine; Appere, Géraldine; Vergnaud, Gilles; Pourcel, Christine

    2015-07-01

    Propionibacterium acnes plays a central role in the pathogenesis of acne and is responsible for severe opportunistic infections. Numerous typing schemes have been developed that allow the identification of phylotypes, but they are often insufficient to differentiate subtypes. To better understand the genetic diversity of this species and to perform epidemiological analyses, high throughput discriminant genotyping techniques are needed. Here we describe the development of a multiple locus variable number of tandem repeats (VNTR) analysis (MLVA) method. Thirteen VNTRs were identified in the genome of P. acnes and were used to genotype a collection of clinical isolates. In addition, publically available sequencing data for 102 genomes were analyzed in silico, providing an MLVA genotype. The clustering of MLVA data was in perfect congruence with whole genome based clustering. Analysis of the clustered regularly interspaced short palindromic repeat (CRISPR) element uncovered new spacers, a supplementary source of genotypic information. The present MLVA13 scheme and associated internet database represents a first line genotyping assay to investigate large number of isolates. Particular strains may then be submitted to full genome sequencing in order to better analyze their pathogenic potential. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Variable Reporting by Authors Presenting Arthroplasty Research at Multiple Annual Conferences.

    Science.gov (United States)

    Choo, Kevin J; Yi, Paul H; Burns, Robert; Mohan, Rohith; Wong, Kevin

    2017-01-01

    Prior studies have demonstrated discrepancies in financial conflict of interest (COI) disclosure among authors presenting research at multiple spine and sports medicine conferences. The purpose of this study was to quantify the variability of self-reported financial disclosures of individual authors presenting at multiple arthroplasty conferences during the same year. The author disclosure information published for the 2012 annual meetings of the American Academy of Orthopaedic Surgeons (AAOS), American Association of Hip and Knee Surgeons, the Hip Society, and the Knee Society were compiled. We tabulated the author disclosures, the number of companies/entities represented, and the types of disclosures reported. The disclosures made by authors presenting at more than one meeting were then compared for discrepancies. Of the 209 authors who presented at both the AAOS and American Association of Hip and Knee Surgeons meetings, 79 (37.79%) demonstrated discrepancies in their disclosures with 7 (8.8%) reporting no disclosures to the AAOS. Of the 84 authors who presented at both the AAOS and Hip Society meetings, 1 (1.19%) had discrepancies in their disclosures. Of the 52 authors who presented at both the AAOS and Knee Society meetings, 2 (3.84%) had discrepancies in their disclosures. There is variability in reported financial COIs by authors presenting at multiple arthroplasty conferences within the same year. Further work is warranted to improve transparency of COI disclosures among arthroplasty surgeons presenting research at national meetings. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.

    Science.gov (United States)

    White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin

    2018-05-15

    Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia

  14. Correction for variable moderation and multiplication effects associated with thermal neutron coincidence counting

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    A correction is described for multiplication and moderation when doing passive thermal neutron coincidence counting nondestructive assay measurements on powder samples of PuO 2 mixed arbitrarily with MgO, SiO 2 , and moderating material. The multiplication correction expression is shown to be approximately separable into the product of two independent terms; F/sub Pu/ which depends on the mass of 240 Pu, and F/sub αn/ which depends on properties of the matrix material. Necessary assumptions for separability are (1) isotopic abundances are constant, and (2) fission cross sections are independent of incident neutron energy: both of which are reasonable for the 8% 240 Pu powder samples considered here. Furthermore since all prompt fission neutrons are expected to have nearly the same energy distributions, variations among different samples can be due only to the moderating properties of the samples. Relative energy distributions are provided by a thermal neutron well counter having two concentric rings of 3 He proportional counters placed symmetrically about the well. Measured outer-to-inner ring ratios raised to an empirically determined power for coincidences, (N/sup I//N/sup O/)/sup Z/, and singles, (T/sup O//T/sup I/)/sup delta/, provide corrections for moderation and F/sub αn/ respectively, and F/sub Pu/ is approximated by M 240 /sup X//M 240 . The exponents are calibration constants determined by a least squares fitting procedure using standards' data. System calibration is greatly simplified using the separability principle. Once appropriate models are established for F/sub Pu/ and F/sub αn/, only a few standards are necessary to determine the calibration constants associated with these terms. Since F/sub Pu/ is expressed as a function of M 240 , correction for multiplication in a subsequent assay demands only a measurement of F/sub αn/

  15. A 16-channel real-time digital processor for pulse-shape discrimination in multiplicity assay

    International Nuclear Information System (INIS)

    Joyce, Malcolm J.; Aspinall, M.D.; Cave, F.D.; Lavietes, A.

    2013-06-01

    In recent years, real-time neutron/γ-ray pulse-shape discrimination has become feasible for use with scintillator-based detectors that respond extremely quickly, on the order of 25 ns in terms of pulse width, and their application to a variety of nuclear material assays has been reported. For the in-situ analysis of nuclear materials, measurements are often based on the multiplicity assessment of spontaneous fission events. An example of this is the 240 Pu eff assessment stemming from long-established techniques developed for 3 He-based neutron coincidence counters when 3 He was abundant and cheap. However, such measurements when using scintillator detectors can be plagued by low detection efficiencies and low orders of coincidence (often limited to triples) if the number of detectors in use is similarly limited to 3-4 detectors. Conversely, an array of >10 detector modules arranged to optimize efficiency and multiplicity sensitivity, shifts the emphasis in terms of performance requirement to the real-time digital analyzer and, critically, to the scope remaining in the temporal processing window of these systems. In this paper we report on the design, development and commissioning of a bespoke, 16-channel real-time pulse-shape discrimination analyzer specified for the materials assay challenge summarized above. The analyzer incorporates 16 dedicated and independent high-voltage supplies along with 16 independent digital processing channels offering pulse-shape discrimination at a rate of 3 x 10 6 events per second. These functions are configured from a dedicated graphical user interface, and all settings can be adjusted on-the-fly with the analyzer effectively configured one-time-only (where desired) for subsequent plug-and-play connection, for example to a fuel bundle organic scintillation detector array. (authors)

  16. Multiple variables explain the variability in the decrement in VO2max during acute hypobaric hypoxia.

    Science.gov (United States)

    Robergs, R A; Quintana, R; Parker, D L; Frankel, C C

    1998-06-01

    We used multiple regression analyses to determine the relationships between the decrement in sea level (SL, 760 Torr) VO2max during hypobaric hypoxia (HH) and variables that could alter or be related to the decrement in VO2max. HH conditions consisted of 682 Torr, 632 Torr, and 566 Torr, and the measured independent variables were SL-VO2max, SL lactate threshold (SL-LT), the change in hemoglobin saturation at VO2max between 760 and 566 Torr (delta SaO2max), lean body mass (LBM), and gender. Male (N = 14) and female (N = 14) subjects of varied fitness, training status, and residential altitude (1,640-2,460 m) completed cycle ergometry tests of VO2max at each HH condition under randomized and single-blinded conditions. VO2max decreased significantly from 760 Torr after 682 Torr (approximately 915 m) (3.5 +/- 0.9 to 3.4 +/- 0.8 L.min-1, P = 0.0003). Across all HH conditions, the slope of the relative decrement in VO2max (%VO2max) during HH was -9.2%/100 mm Hg (-8.1%/1000 m) with an initial decrease from 100% estimated to occur below 705 Torr (610 m). Step-wise multiple regression revealed that SL-VO2max, SL-LT, delta SaO2max, LBM, and gender each significantly combined to account for 89.03% of the variance in the decrement in VO2max (760-566 Torr) (P decrement in VO2max during HH. The unique variance explanation afforded by SL-LT, LBM, and gender suggests that issues pertaining to oxygen diffusion within skeletal muscle may add to the explanation of between subjects variability in the decrement in VO2max during HH.

  17. Evaluation of a multiple-cycle, recombinant virus, growth competition assay that uses flow cytometry to measure replication efficiency of human immunodeficiency virus type 1 in cell culture.

    Science.gov (United States)

    Dykes, Carrie; Wang, Jiong; Jin, Xia; Planelles, Vicente; An, Dong Sung; Tallo, Amanda; Huang, Yangxin; Wu, Hulin; Demeter, Lisa M

    2006-06-01

    Human immunodeficiency virus type 1 (HIV-1) replication efficiency or fitness, as measured in cell culture, has been postulated to correlate with clinical outcome of HIV infection, although this is still controversial. One limitation is the lack of high-throughput assays that can measure replication efficiency over multiple rounds of replication. We have developed a multiple-cycle growth competition assay to measure HIV-1 replication efficiency that uses flow cytometry to determine the relative proportions of test and reference viruses, each of which expresses a different reporter gene in place of nef. The reporter genes are expressed on the surface of infected cells and are detected by commercially available fluorescence-labeled antibodies. This method is less labor-intensive than those that require isolation and amplification of nucleic acids. The two reporter gene products are detected with similar specificity and sensitivity, and the proportion of infected cells in culture correlates with the amount of viral p24 antigen produced in the culture supernatant. HIV replication efficiencies of six different drug-resistant site-directed mutants were reproducibly quantified and were similar to those obtained with a growth competition assay in which the relative proportion of each variant was measured by sequence analysis, indicating that recombination between the pol and reporter genes was negligible. This assay also reproducibly quantified the relative fitness conferred by protease and reverse transcriptase sequences containing multiple drug resistance mutations, amplified from patient plasma. This flow cytometry-based growth competition assay offers advantages over current assays for HIV replication efficiency and should prove useful for the evaluation of patient samples in clinical trials.

  18. Controlling variation in the comet assay

    Directory of Open Access Journals (Sweden)

    Andrew Richard Collins

    2014-10-01

    Full Text Available Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardising the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of alkaline incubation, and electrophoresis conditions (time, temperature and voltage gradient are particularly important. Even when these are controlled, variation seems to be inevitable. It is helpful to include in experiments reference standards, i.e. cells with a known amount of specific damage to the DNA. They can be aliquots frozen from a single large batch of cells, either untreated (negative controls or treated with, for example, H2O2 or X-rays to induce strand breaks (positive control for the basic assay, or photosensitiser plus light to oxidise guanine (positive control for Fpg- or OGG1-sensitive sites. Reference standards are especially valuable when performing a series of experiments over a long period - for example, analysing samples of white blood cells from a large human biomonitoring trial - to check that the assay is performing consistently, and to identify anomalous results necessitating a repeat experiment. The reference values of tail intensity can also be used to iron out small variations occurring from day to day. We present examples of the use of reference standards in human trials, both within one laboratory and between different laboratories, and describe procedures that can be used to control variation.

  19. Simultaneous assay of multiple antibiotics in human plasma by LC-MS/MS: importance of optimizing formic acid concentration.

    Science.gov (United States)

    Chen, Feng; Hu, Zhe-Yi; Laizure, S Casey; Hudson, Joanna Q

    2017-03-01

    Optimal dosing of antibiotics in critically ill patients is complicated by the development of resistant organisms requiring treatment with multiple antibiotics and alterations in systemic exposure due to diseases and extracorporeal drug removal. Developing guidelines for optimal antibiotic dosing is an important therapeutic goal requiring robust analytical methods to simultaneously measure multiple antibiotics. An LC-MS/MS assay using protein precipitation for cleanup followed by a 6-min gradient separation was developed to simultaneously determine five antibiotics in human plasma. The precision and accuracy were within the 15% acceptance range. The formic acid concentration was an important determinant of signal intensity, peak shape and matrix effects. The method was designed to be simple and successfully applied to a clinical pharmacokinetic study.

  20. Analysis of the Local Lymph Node Assay (LLNA) variability for assessing the prediction of skin sensitisation potential and potency of chemicals with non-animal approaches.

    Science.gov (United States)

    Dumont, Coralie; Barroso, João; Matys, Izabela; Worth, Andrew; Casati, Silvia

    2016-08-01

    The knowledge of the biological mechanisms leading to the induction of skin sensitisation has favoured in recent years the development of alternative non-animal methods. During the formal validation process, results from the Local Lymph Node Assay (LLNA) are generally used as reference data to assess the predictive capacity of the non-animal tests. This study reports an analysis of the variability of the LLNA for a set of chemicals for which multiple studies are available and considers three hazard classification schemes: POS/NEG, GHS/CLP and ECETOC. As the type of vehicle used in a LLNA study is known to influence to some extent the results, two analyses were performed: considering the solvent used to test the chemicals and without considering the solvent. The results show that the number of discordant classifications increases when a chemical is tested in more than one solvent. Moreover, it can be concluded that study results leading to classification in the strongest classes (1A and EXT) seem to be more reliable than those in the weakest classes. This study highlights the importance of considering the variability of the reference data when evaluating non-animal tests. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Analysis of the diversity of murine antibodies to dextran B1355. II. Demonstration of multiple idiotypes with variable expression in several strains

    International Nuclear Information System (INIS)

    Hansburg, D.; Briles, D.E.; Davie, J.M.

    1977-01-01

    We have developed radioimmunoassays that detect idiotypic (variable region) differences among the α(1 → 3) dextran-binding myeloma proteins U102, J558, and M104 as well as an assay that detects variable region determinants common to all three proteins. Using these assays, we have examined 7S and 19S anti-α(1 → 3) dextran antibodies induced in five murine strains of the a 1 I/sub g/C/sub H/ linkage group and the recombinant strain BAB/14. All idiotypes were expressed in both 19S and 7S antibodies from all strains, but with considerable strain-specific variability in penetrance. In two strains, one additional type of antibody, which lacked all four idiotypic determinants, generally constituted the bulk of total anti-α(1 → 3) dextran antibodies

  2. Comparison of mRNA splicing assay protocols across multiple laboratories: recommendations for best practice in standardized clinical testing.

    Science.gov (United States)

    Whiley, Phillip J; de la Hoya, Miguel; Thomassen, Mads; Becker, Alexandra; Brandão, Rita; Pedersen, Inge Sokilde; Montagna, Marco; Menéndez, Mireia; Quiles, Francisco; Gutiérrez-Enríquez, Sara; De Leeneer, Kim; Tenés, Anna; Montalban, Gemma; Tserpelis, Demis; Yoshimatsu, Toshio; Tirapo, Carole; Raponi, Michela; Caldes, Trinidad; Blanco, Ana; Santamariña, Marta; Guidugli, Lucia; de Garibay, Gorka Ruiz; Wong, Ming; Tancredi, Mariella; Fachal, Laura; Ding, Yuan Chun; Kruse, Torben; Lattimore, Vanessa; Kwong, Ava; Chan, Tsun Leung; Colombo, Mara; De Vecchi, Giovanni; Caligo, Maria; Baralle, Diana; Lázaro, Conxi; Couch, Fergus; Radice, Paolo; Southey, Melissa C; Neuhausen, Susan; Houdayer, Claude; Fackenthal, Jim; Hansen, Thomas Van Overeem; Vega, Ana; Diez, Orland; Blok, Rien; Claes, Kathleen; Wappenschmidt, Barbara; Walker, Logan; Spurdle, Amanda B; Brown, Melissa A

    2014-02-01

    Accurate evaluation of unclassified sequence variants in cancer predisposition genes is essential for clinical management and depends on a multifactorial analysis of clinical, genetic, pathologic, and bioinformatic variables and assays of transcript length and abundance. The integrity of assay data in turn relies on appropriate assay design, interpretation, and reporting. We conducted a multicenter investigation to compare mRNA splicing assay protocols used by members of the ENIGMA (Evidence-Based Network for the Interpretation of Germline Mutant Alleles) consortium. We compared similarities and differences in results derived from analysis of a panel of breast cancer 1, early onset (BRCA1) and breast cancer 2, early onset (BRCA2) gene variants known to alter splicing (BRCA1: c.135-1G>T, c.591C>T, c.594-2A>C, c.671-2A>G, and c.5467+5G>C and BRCA2: c.426-12_8delGTTTT, c.7988A>T, c.8632+1G>A, and c.9501+3A>T). Differences in protocols were then assessed to determine which elements were critical in reliable assay design. PCR primer design strategies, PCR conditions, and product detection methods, combined with a prior knowledge of expected alternative transcripts, were the key factors for accurate splicing assay results. For example, because of the position of primers and PCR extension times, several isoforms associated with BRCA1, c.594-2A>C and c.671-2A>G, were not detected by many sites. Variation was most evident for the detection of low-abundance transcripts (e.g., BRCA2 c.8632+1G>A Δ19,20 and BRCA1 c.135-1G>T Δ5q and Δ3). Detection of low-abundance transcripts was sometimes addressed by using more analytically sensitive detection methods (e.g., BRCA2 c.426-12_8delGTTTT ins18bp). We provide recommendations for best practice and raise key issues to consider when designing mRNA assays for evaluation of unclassified sequence variants.

  3. Single-cell multiple gene expression analysis based on single-molecule-detection microarray assay for multi-DNA determination

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Wang, Xianwei [School of Life Sciences, Shandong University, Jinan 250100 (China); Zhang, Xiaoli [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Wang, Jinxing [School of Life Sciences, Shandong University, Jinan 250100 (China); Jin, Wenrui, E-mail: jwr@sdu.edu.cn [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2015-01-07

    Highlights: • A single-molecule-detection (SMD) microarray for 10 samples is fabricated. • The based-SMD microarray assay (SMA) can determine 8 DNAs for each sample. • The limit of detection of SMA is as low as 1.3 × 10{sup −16} mol L{sup −1}. • The SMA can be applied in single-cell multiple gene expression analysis. - Abstract: We report a novel ultra-sensitive and high-selective single-molecule-detection microarray assay (SMA) for multiple DNA determination. In the SMA, a capture DNA (DNAc) microarray consisting of 10 subarrays with 9 spots for each subarray is fabricated on a silanized glass coverslip as the substrate. On the subarrays, the spot-to-spot spacing is 500 μm and each spot has a diameter of ∼300 μm. The sequence of the DNAcs on the 9 spots of a subarray is different, to determine 8 types of target DNAs (DNAts). Thus, 8 types of DNAts are captured to their complementary DNAcs at 8 spots of a subarray, respectively, and then labeled with quantum dots (QDs) attached to 8 types of detection DNAs (DNAds) with different sequences. The ninth spot is used to detect the blank value. In order to determine the same 8 types of DNAts in 10 samples, the 10 DNAc-modified subarrays on the microarray are identical. Fluorescence single-molecule images of the QD-labeled DNAts on each spot of the subarray are acquired using a home-made single-molecule microarray reader. The amounts of the DNAts are quantified by counting the bright dots from the QDs. For a microarray, 8 types of DNAts in 10 samples can be quantified in parallel. The limit of detection of the SMA for DNA determination is as low as 1.3 × 10{sup −16} mol L{sup −1}. The SMA for multi-DNA determination can also be applied in single-cell multiple gene expression analysis through quantification of complementary DNAs (cDNAs) corresponding to multiple messenger RNAs (mRNAs) in single cells. To do so, total RNA in single cells is extracted and reversely transcribed into their cDNAs. Three

  4. Coordinating the effects of multiple variables: a skill fundamental to scientific thinking.

    Science.gov (United States)

    Kuhn, Deanna; Pease, Maria; Wirkala, Clarice

    2009-07-01

    The skill of predicting outcomes based on simultaneous effects of multiple factors was examined. Over five sessions, 91 sixth graders engaged this task either individually or in pairs and either preceded or followed by six sessions on the more widely studied inquiry task that requires designing and interpreting experiments to identify individual effects. Final assessment, while indicating a high level of mastery on the inquiry task, showed progress but continuing conceptual challenges on the multivariable prediction task having to do with understanding of variables, variable levels, and consistency of a variable's operation across occasions. Task order had a significant but limited effect, and social collaboration conferred only a temporary benefit that disappeared in a final individual assessment. In a follow-up study, the lack of effect of social collaboration was confirmed, as was that of feedback on incorrect answers. Although fundamental to science, the concept that variables operate jointly and, under equivalent conditions, consistently across occasions is one that children appear to acquire only gradually and, therefore, one that cannot be assumed to be in place.

  5. Development of a real-time multiplex PCR assay for the detection of multiple Salmonella serotypes in chicken samples

    Directory of Open Access Journals (Sweden)

    Whyte Paul

    2008-09-01

    Full Text Available Abstract Background A real-time multiplex PCR assay was developed for the detection of multiple Salmonella serotypes in chicken samples. Poultry-associated serotypes detected in the assay include Enteritidis, Gallinarum, Typhimurium, Kentucky and Dublin. The traditional cultural method according to EN ISO 6579:2002 for the detection of Salmonella in food was performed in parallel. The real-time PCR based method comprised a pre-enrichment step in Buffered Peptone Water (BPW overnight, followed by a shortened selective enrichment in Rappaport Vasilliadis Soya Broth (RVS for 6 hours and subsequent DNA extraction. Results The real-time multiplex PCR assay and traditional cultural method showed 100% inclusivity and 100% exclusivity on all strains tested. The real-time multiplex PCR assay was as sensitive as the traditional cultural method in detecting Salmonella in artificially contaminated chicken samples and correctly identified the serotype. Artificially contaminated chicken samples resulted in a detection limit of between 1 and 10 CFU per 25 g sample for both methods. A total of sixty-three naturally contaminated chicken samples were investigated by both methods and relative accuracy, relative sensitivity and relative specificity of the real-time PCR method were determined to be 89, 94 and 87%, respectively. Thirty cultures blind tested were correctly identified by the real-time multiplex PCR method. Conclusion Real-time PCR methodology can contribute to meet the need for rapid identification and detection methods in food testing laboratories.

  6. Development of an Indirect Competitive Enzyme-Linked Immunosorbent Assay for Glycocholic Acid Based on Chicken Single-Chain Variable Fragment Antibodies.

    Science.gov (United States)

    Cui, Xiping; Vasylieva, Natalia; Wu, Panpan; Barnych, Bogdan; Yang, Jun; Shen, Ding; He, Qiyi; Gee, Shirley J; Zhao, Suqing; Hammock, Bruce D

    2017-10-17

    Glycocholic acid (GCA) is an important metabolite of bile acids, whose urine levels are expected to be a specific diagnostic biomarker for hepatocellular carcinoma (HCC). A high-throughput immunoassay for determination of GCA would be of significant advantage and useful for primary diagnosis, surveillance, and early detection of HCC. Single-chain variable fragment (scFv) antibodies have several desirable characteristics and are an attractive alternative to traditional antibodies for the immunoassay. Because chicken antibodies possess single heavy and light variable functional domains, they are an ideal framework for simplified generation of recombinant antibodies for GCA detection. However, chicken scFvs have rarely been used to detect GCA. In this study, a scFv library was generated from chickens immunized with a GCA hapten coupled to bovine serum albumin (BSA), and anti-GCA scFvs were isolated by a phage-displayed method. Compared to the homologous coating antigen, use of a heterologous coating antigen resulted in about an 85-fold improvement in sensitivity of the immunoassay. This assay, under optimized conditions, had a linear range of 0.02-0.18 μg/mL, with an IC 50 of 0.06 μg/mL. The assay showed negligible cross-reactivity with various related bile acids, except for taurocholic acid. The detection of GCA from spiked human urine samples ranged from 86.7% to 123.3%. These results, combined with the advantages of scFv antibodies, indicated that a chicken scFv-based enzyme-linked immunosorbent assay is a suitable method for high-throughput screening of GCA in human urine.

  7. A multiwell format assay for heparanase.

    Science.gov (United States)

    Behzad, Farhad; Brenchley, Paul E C

    2003-09-15

    This assay employs a biotinylated heparan sulfate glycosaminoglycan (HSGAG) substrate that is covalently linked to the surface of 96-well immunoassay plates. The ratio of biotin:HSGAG and the coating concentration of substrate bound to the wells have been optimized and allow removal of biotin HSGAG within 60 min of incubation at 37 degrees C in assay buffer with a standard dilution of bacterial heparitinase or platelet heparanase. Loss of biotin signal from the well surface is detected on incubation with peroxidase-streptavidin followed by color development using 3,3',5,5'-tetramethylbenzidine as the peroxidase substrate. The new assay allows specific detection of heparanase activity in multiple samples in a total time of 3 h including a 1-h substrate digestion step and is a significant improvement with regard to sensitivity, specificity, and ease of handling of multiple samples compared to other described assays. Heparanase specifically degrades the biotinylated HSGAG substrate, when used with an optimized assay buffer. A range of enzymes including collagenase, trypsin, plasmin, pepsin, chondroitinases, hyaluronidase, and neuraminidase show no effect on the substrate under optimized assay conditions. The covalent linkage of the substrate to the well prevents leaching of substrate and allows preparation and long-term storage of substrate-coated plates. The assay can be used to detect heparanase levels in clinical samples and cell culture supernatants and is ideal as a screening method for antagonists of enzyme activity.

  8. A multiple biomarker assay for quality assessment of botanical drugs using a versatile microfluidic chip.

    Science.gov (United States)

    Li, Zhen-Hao; Ai, Ni; Yu, Lawrence X; Qian, Zhong-Zhi; Cheng, Yi-Yu

    2017-09-25

    Quality control is critical for ensuring the safety and effectiveness of drugs. Current quality control method for botanical drugs is mainly based on chemical testing. However, chemical testing alone may not be sufficient as it may not capture all constituents of botanical drugs. Therefore, it is necessary to establish a bioassay correlating with the drug's known mechanism of action to ensure its potency and activity. Herein we developed a multiple biomarker assay to assess the quality of botanicals using microfluidics, where enzyme inhibition was employed to indicate the drug's activity and thereby evaluate biological consistency. This approach was exemplified on QiShenYiQi Pills using thrombin and angiotensin converting enzyme as "quality biomarkers". Our results demonstrated that there existed variations in potency across different batches of the intermediates and preparations. Compared with chromatographic fingerprinting, the bioassay provided better discrimination ability for some abnormal samples. Moreover, the chip could function as "affinity chromatography" to identify bioactive phytochemicals bound to the enzymes. This work proposed a multiple-biomarker strategy for quality assessment of botanical drugs, while demonstrating for the first time the feasibility of microfluidics in this field.

  9. Qualification of standard membrane-feeding assay with Plasmodium falciparum malaria and potential improvements for future assays.

    Directory of Open Access Journals (Sweden)

    Kazutoyo Miura

    Full Text Available Vaccines that interrupt malaria transmission are of increasing interest and a robust functional assay to measure this activity would promote their development by providing a biologically relevant means of evaluating potential vaccine candidates. Therefore, we aimed to qualify the standard membrane-feeding assay (SMFA. The assay measures the transmission-blocking activity of antibodies by feeding cultured P. falciparum gametocytes to Anopheles mosquitoes in the presence of the test antibodies and measuring subsequent mosquito infection. The International Conference on Harmonisation (ICH Harmonised Tripartite Guideline Q2(R1 details characteristics considered in assay validation. Of these characteristics, we decided to qualify the SMFA for Precision, Linearity, Range and Specificity. The transmission-blocking 4B7 monoclonal antibody was tested over 6 feeding experiments at several concentrations to determine four suitable concentrations that were tested in triplicate in the qualification experiments (3 additional feeds to evaluate Precision, Linearity and Range. For Specificity, 4B7 was tested in the presence of normal mouse IgG. We determined intra- and inter-assay variability of % inhibition of mean oocyst intensity at each concentration of 4B7 (lower concentrations showed higher variability. We also showed that % inhibition was dependent on 4B7 concentration and the activity is specific to 4B7. Since obtaining empirical data is time-consuming, we generated a model using data from all 9 feeds and simulated the effects of different parameters on final readouts to improve the assay procedure and analytical methods for future studies. For example, we estimated the effect of number of mosquitoes dissected on variability of % inhibition, and simulated the relationship between % inhibition in oocyst intensity and % inhibition of prevalence of infected mosquitos at different mean oocysts in the control. SMFA is one of the few biological assays used in

  10. Datafish Multiphase Data Mining Technique to Match Multiple Mutually Inclusive Independent Variables in Large PACS Databases.

    Science.gov (United States)

    Kelley, Brendan P; Klochko, Chad; Halabi, Safwan; Siegal, Daniel

    2016-06-01

    Retrospective data mining has tremendous potential in research but is time and labor intensive. Current data mining software contains many advanced search features but is limited in its ability to identify patients who meet multiple complex independent search criteria. Simple keyword and Boolean search techniques are ineffective when more complex searches are required, or when a search for multiple mutually inclusive variables becomes important. This is particularly true when trying to identify patients with a set of specific radiologic findings or proximity in time across multiple different imaging modalities. Another challenge that arises in retrospective data mining is that much variation still exists in how image findings are described in radiology reports. We present an algorithmic approach to solve this problem and describe a specific use case scenario in which we applied our technique to a real-world data set in order to identify patients who matched several independent variables in our institution's picture archiving and communication systems (PACS) database.

  11. Generic and sequence-variant specific molecular assays for the detection of the highly variable Grapevine leafroll-associated virus 3.

    Science.gov (United States)

    Chooi, Kar Mun; Cohen, Daniel; Pearson, Michael N

    2013-04-01

    Grapevine leafroll-associated virus 3 (GLRaV-3) is an economically important virus, which is found in all grapevine growing regions worldwide. Its accurate detection in nursery and field samples is of high importance for certification schemes and disease management programmes. To reduce false negatives that can be caused by sequence variability, a new universal primer pair was designed against a divergent sequence data set, targeting the open reading frame 4 (heat shock protein 70 homologue gene), and optimised for conventional one-step RT-PCR and one-step SYBR Green real-time RT-PCR assays. In addition, primer pairs for the simultaneous detection of specific GLRaV-3 variants from groups 1, 2, 6 (specifically NZ-1) and the outlier NZ2 variant, and the generic detection of variants from groups 1 to 5 were designed and optimised as a conventional one-step multiplex RT-PCR assay using the plant nad5 gene as an internal control (i.e. one-step hexaplex RT-PCR). Results showed that the generic and variant specific assays detected in vitro RNA transcripts from a range of 1×10(1)-1×10(8) copies of amplicon per μl diluted in healthy total RNA from Vitis vinifera cv. Cabernet Sauvignon. Furthermore, the assays were employed effectively to screen 157 germplasm and 159 commercial field samples. Thus results demonstrate that the GLRaV-3 generic and variant-specific assays are prospective tools that will be beneficial for certification schemes and disease management programmes, as well as biological and epidemiological studies of the divergent GLRaV-3 populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    Science.gov (United States)

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Random assay in radioimmunoassay: Feasibility and application compared with batch assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, Hwan Hee; Park, Sohyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear MedicineNational Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice. The coefficients of variation (CVs) of eight standard curves within a single kit were calculated in a CA-125 immunoradiometric assay (IRMA) for the reference of the practically ideal CV of the CA-125 kit. Ten standard curves of 10 kits from 2 prospectively collected lots (pLot) and 85 standard curves of 85 kits from 3 retrospectively collected lots (Lot) were obtained. Additionally, the raw measurement data of both 170 control references and 1123 patients' sera were collected retrospectively between December 2015 and January 2016. A standard curve of the first kit of each lot was used as a master standard curve for a random assay. The CVs of inter-kits were analyzed in each lot, respectively. All raw measurements were normalized by decay and radioactivity. The CA-125 values from control samples and patients' sera were compared using the original batch assay and random assay. In standard curve analysis, the CVs of inter-kits in pLots and Lots were comparable to those within a single kit. The CVs from the random assay with normalization were similar to those from the batch assay in the control samples (CVs % of low/high concentration; Lot1 2.71/1.91, Lot2 2.35/1.83, Lot3 2.83/2.08 vs. Lot1 2.05/1.21, Lot2 1.66/1.48, Lot3 2.41/2.14). The ICCs between the batch assay and random assay using patients' sera were satisfactory (Lot1 1.00, Lot2 0.999, Lot3 1.00). The random assay technique could be successfully applied to the conventional CA-125 IRMA kits. The random assay showed strong agreement with the batch assay. The

  14. Standardization of the CFU-GM assay: Advantages of plating a fixed number of CD34+ cells in collagen gels.

    Science.gov (United States)

    Dobo, Irène; Pineau, Danielle; Robillard, Nelly; Geneviève, Frank; Piard, Nicole; Zandecki, Marc; Hermouet, Sylvie

    2003-10-01

    We investigated whether plating a stable amount of CD34(+) cells improves the CFU-GM assay. Data of CFU-GM assays performed with leukaphereses products in two transplant centers using a commercial collagen-based medium and unified CFU-GM scoring criteria were pooled and analyzed according to the numbers of CD34(+) cells plated. A first series of 113 CFU-GM assays was performed with a fixed number of mononuclear cells (i.e., a variable number of CD34(+) cells). In these cultures the CFU-GM/CD34 ratio varied according to the number of CD34(+) cells plated: median CFUGM/CD34 ratios were 1/6.2 to 1/6.6 for grafts containing or =2% CD34(+) cells. The median CFU-GM/CD34 ratio also varied depending on pathology: 1/9.3 for multiple myeloma (MM), 1/6.8 for Hodgkin's disease (HD), 1/6.5 for non-Hodgkin lymphoma (NHL), and 1/4.5 for solid tumors (ST). A second series of 95 CFU-GM assays was performed with a fixed number of CD34(+) cells (220/ml). The range of median CFU-GM/CD34 ratios was narrowed to 1/7.0 to 1/5.2, and coefficients of variation for CFU-GM counts decreased by half to 38.1% (NHL), 36.1% (MM), 49.9% (HD), and 22.4% (ST). In addition, CFU-GM scoring was facilitated as the percentages of cultures with >50 CFU/GM/ml decreased from 6.7% to 43.8% when a variable number of CD34(+) cells was plated, to 4.5% to 16.7% when 220 CD34(+) cells/ml were plated. Hence, plating a fixed number of CD34(+) cells in collagen gels improves the CFU-GM assay by eliminating cell number-related variability and reducing pathology-related variability in colony growth.

  15. Within-day variability on short and long walking tests in persons with multiple sclerosis

    NARCIS (Netherlands)

    Feys, P.; Bibby, B.; Romberg, A.; Santoyo, C.; Gebara, B.; de Noordhout, B.M.; Knuts, K.; Bethoux, F.; Skjerbaek, A.; Jensen, E.; Baert, I.; Vaney, C.; de Groot, V.; Dalgas, U.

    2014-01-01

    Objective To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Design Observational study. Setting MS rehabilitation and research centers in Europe and US within

  16. Modulation of brain activity by multiple lexical and word form variables in visual word recognition: A parametric fMRI study.

    Science.gov (United States)

    Hauk, Olaf; Davis, Matthew H; Pulvermüller, Friedemann

    2008-09-01

    Psycholinguistic research has documented a range of variables that influence visual word recognition performance. Many of these variables are highly intercorrelated. Most previous studies have used factorial designs, which do not exploit the full range of values available for continuous variables, and are prone to skewed stimulus selection as well as to effects of the baseline (e.g. when contrasting words with pseudowords). In our study, we used a parametric approach to study the effects of several psycholinguistic variables on brain activation. We focussed on the variable word frequency, which has been used in numerous previous behavioural, electrophysiological and neuroimaging studies, in order to investigate the neuronal network underlying visual word processing. Furthermore, we investigated the variable orthographic typicality as well as a combined variable for word length and orthographic neighbourhood size (N), for which neuroimaging results are still either scarce or inconsistent. Data were analysed using multiple linear regression analysis of event-related fMRI data acquired from 21 subjects in a silent reading paradigm. The frequency variable correlated negatively with activation in left fusiform gyrus, bilateral inferior frontal gyri and bilateral insulae, indicating that word frequency can affect multiple aspects of word processing. N correlated positively with brain activity in left and right middle temporal gyri as well as right inferior frontal gyrus. Thus, our analysis revealed multiple distinct brain areas involved in visual word processing within one data set.

  17. Development and validation of a quantitative PCR assay for Ichthyophonus spp.

    Science.gov (United States)

    White, Vanessa C; Morado, J Frank; Crosson, Lisa M; Vadopalas, Brent; Friedman, Carolyn S

    2013-04-29

    Members of the genus Ichthyophonus are trophically transmitted, cosmopolitan parasites that affect numerous fish species worldwide. A quantitative PCR (qPCR) assay specific for genus Ichthyophonus 18S ribosomal DNA was developed for parasite detection and surveillance. The new assay was tested for precision, repeatability, reproducibility, and both analytical sensitivity and specificity. Diagnostic sensitivity and specificity were estimated using tissue samples from a wild population of walleye pollock Theragra chalcogramma. Ichthyophonus sp. presence in tissue samples was determined by qPCR, conventional PCR (cPCR), and histology. Parasite prevalence estimates varied depending upon the detection method employed and tissue type tested. qPCR identified the greatest number of Ichthyophonus sp.-positive cases when applied to walleye pollock skeletal muscle. The qPCR assay proved sensitive and specific for Ichthyophonus spp. DNA, but like cPCR, is only a proxy for infection. When compared to cPCR, qPCR possesses added benefits of parasite DNA quantification and a 100-fold increase in analytical sensitivity. Because this novel assay is specific for known members of the genus, it is likely appropriate for detecting Ichthyophonus spp. DNA in various hosts from multiple regions. However, species-level identification and isotype variability would require DNA sequencing. In addition to distribution and prevalence applications, this assay could be modified and adapted for use with zooplankton or environmental samples. Such applications could aid in investigating alternate routes of transmission and life history strategies typical to members of the genus Ichthyophonus.

  18. Sample preparation composite and replicate strategy for assay of solid oral drug products.

    Science.gov (United States)

    Harrington, Brent; Nickerson, Beverly; Guo, Michele Xuemei; Barber, Marc; Giamalva, David; Lee, Carlos; Scrivens, Garry

    2014-12-16

    In pharmaceutical analysis, the results of drug product assay testing are used to make decisions regarding the quality, efficacy, and stability of the drug product. In order to make sound risk-based decisions concerning drug product potency, an understanding of the uncertainty of the reportable assay value is required. Utilizing the most restrictive criteria in current regulatory documentation, a maximum variability attributed to method repeatability is defined for a drug product potency assay. A sampling strategy that reduces the repeatability component of the assay variability below this predefined maximum is demonstrated. The sampling strategy consists of determining the number of dosage units (k) to be prepared in a composite sample of which there may be a number of equivalent replicate (r) sample preparations. The variability, as measured by the standard error (SE), of a potency assay consists of several sources such as sample preparation and dosage unit variability. A sampling scheme that increases the number of sample preparations (r) and/or number of dosage units (k) per sample preparation will reduce the assay variability and thus decrease the uncertainty around decisions made concerning the potency of the drug product. A maximum allowable repeatability component of the standard error (SE) for the potency assay is derived using material in current regulatory documents. A table of solutions for the number of dosage units per sample preparation (r) and number of replicate sample preparations (k) is presented for any ratio of sample preparation and dosage unit variability.

  19. Multiple Regression and Mediator Variables can be used to Avoid Double Counting when Economic Values are Derived using Stochastic Herd Simulation

    DEFF Research Database (Denmark)

    Østergaard, Søren; Ettema, Jehan Frans; Hjortø, Line

    Multiple regression and model building with mediator variables was addressed to avoid double counting when economic values are estimated from data simulated with herd simulation modeling (using the SimHerd model). The simulated incidence of metritis was analyzed statistically as the independent v...... in multiparous cows. The merit of using this approach was demonstrated since the economic value of metritis was estimated to be 81% higher when no mediator variables were included in the multiple regression analysis......Multiple regression and model building with mediator variables was addressed to avoid double counting when economic values are estimated from data simulated with herd simulation modeling (using the SimHerd model). The simulated incidence of metritis was analyzed statistically as the independent...... variable, while using the traits representing the direct effects of metritis on yield, fertility and occurrence of other diseases as mediator variables. The economic value of metritis was estimated to be €78 per 100 cow-years for each 1% increase of metritis in the period of 1-100 days in milk...

  20. Genotyping of Bacillus anthracis strains based on automated capillary 25-loci Multiple Locus Variable-Number Tandem Repeats Analysis

    Directory of Open Access Journals (Sweden)

    Ciervo Alessandra

    2006-04-01

    Full Text Available Abstract Background The genome of Bacillus anthracis, the etiological agent of anthrax, is highly monomorphic which makes differentiation between strains difficult. A Multiple Locus Variable-number tandem repeats (VNTR Analysis (MLVA assay based on 20 markers was previously described. It has considerable discrimination power, reproducibility, and low cost, especially since the markers proposed can be typed by agarose-gel electrophoresis. However in an emergency situation, faster genotyping and access to representative databases is necessary. Results Genotyping of B. anthracis reference strains and isolates from France and Italy was done using a 25 loci MLVA assay combining 21 previously described loci and 4 new ones. DNA was amplified in 4 multiplex PCR reactions and the length of the resulting 25 amplicons was estimated by automated capillary electrophoresis. The results were reproducible and the data were consistent with other gel based methods once differences in mobility patterns were taken into account. Some alleles previously unresolved by agarose gel electrophoresis could be resolved by capillary electrophoresis, thus further increasing the assay resolution. One particular locus, Bams30, is the result of a recombination between a 27 bp tandem repeat and a 9 bp tandem repeat. The analysis of the array illustrates the evolution process of tandem repeats. Conclusion In a crisis situation of suspected bioterrorism, standardization, speed and accuracy, together with the availability of reference typing data are important issues, as illustrated by the 2001 anthrax letters event. In this report we describe an upgrade of the previously published MLVA method for genotyping of B. anthracis and apply the method to the typing of French and Italian B. anthracis strain collections. The increased number of markers studied compared to reports using only 8 loci greatly improves the discrimination power of the technique. An Italian strain belonging to the

  1. Comparison of Enzymatic Assay and Multiple Tube Fermentation Technique in the Assessment of Microbial Quality of the Karoon River

    Directory of Open Access Journals (Sweden)

    Mahnaz Nikaeen

    2010-09-01

    Full Text Available Microbiological monitoring of surface waters designated for use as drinking water is essential by water utilities for the design and operation of drinking water treatment plants. Enzymatic assays have been applied as a rapid alternative approach to assess the microbiological quality of freshwater. In this study, the LMX broth (LMX as an enzymatic assay was compared with the standard method of multiple tube fermentation technique (MTF for the microbial monitoring of the Karoon River. Enumeration of total coliforms and E. coli averaged 9928 and 6684 MPN/ 100 ml by the LMX and 7564 and 6546 MPN/ 100 ml for the MTF, respectively. This difference was statistically significant for TC but the overall analysis revealed no difference between E. coli recoveries on LMX and MTF. In conclusion, LMX can be used for the enumeration of coliforms and E. coli in surface waters as it is less lobar-intensive, yields faster result, and simultaneously detects both total coliforms and E. coli.

  2. Langevin dynamics for vector variables driven by multiplicative white noise: A functional formalism

    Science.gov (United States)

    Moreno, Miguel Vera; Arenas, Zochil González; Barci, Daniel G.

    2015-04-01

    We discuss general multidimensional stochastic processes driven by a system of Langevin equations with multiplicative white noise. In particular, we address the problem of how time reversal diffusion processes are affected by the variety of conventions available to deal with stochastic integrals. We present a functional formalism to build up the generating functional of correlation functions without any type of discretization of the Langevin equations at any intermediate step. The generating functional is characterized by a functional integration over two sets of commuting variables, as well as Grassmann variables. In this representation, time reversal transformation became a linear transformation in the extended variables, simplifying in this way the complexity introduced by the mixture of prescriptions and the associated calculus rules. The stochastic calculus is codified in our formalism in the structure of the Grassmann algebra. We study some examples such as higher order derivative Langevin equations and the functional representation of the micromagnetic stochastic Landau-Lifshitz-Gilbert equation.

  3. Automation of the anthrone assay for carbohydrate concentration determinations.

    Science.gov (United States)

    Turula, Vincent E; Gore, Thomas; Singh, Suddham; Arumugham, Rasappa G

    2010-03-01

    Reported is the adaptation of a manual polysaccharide assay applicable for glycoconjugate vaccines such as Prevenar to an automated liquid handling system (LHS) for improved performance. The anthrone assay is used for carbohydrate concentration determinations and was scaled to the microtiter plate format with appropriate mixing, dispensing, and measuring operations. Adaptation and development of the LHS platform was performed with both dextran polysaccharides of various sizes and pneumococcal serotype 6A polysaccharide (PnPs 6A). A standard plate configuration was programmed such that the LHS diluted both calibration standards and a test sample multiple times with six replicate preparations per dilution. This extent of replication minimized the effect of any single deviation or delivery error that might have occurred. Analysis of the dextran polymers ranging in size from 214 kDa to 3.755 MDa showed that regardless of polymer chain length the hydrolysis was complete, as evident by uniform concentration measurements. No plate positional absorbance bias was observed; of 12 plates analyzed to examine positional bias the largest deviation observed was 0.02% percent relative standard deviation (%RSD). The high purity dextran also afforded the opportunity to assess LHS accuracy; nine replicate analyses of dextran yielded a mean accuracy of 101% recovery. As for precision, a total of 22 unique analyses were performed on a single lot of PnPs 6A, and the resulting variability was 2.5% RSD. This work demonstrated the capability of a LHS to perform the anthrone assay consistently and a reduced assay cycle time for greater laboratory capacity.

  4. Radioreceptor assays: plasma membrane receptors and assays for polypeptide and glycoprotein hormones

    International Nuclear Information System (INIS)

    Schulster, D.

    1977-01-01

    Receptors for peptide, protein and glycoprotein hormones, and the catecholamines are located on the plasma membranes of their target cells. Preparations of the receptors may be used as specific, high-affinity binding agents for these hormones in assay methodology akin to that for radioimmunoassay. A particular advantage of the radioreceptor assay is that it has a specificity directed towards the biologically active region of the hormone, rather than to some immunologically active region that may have little (or no) involvement in the expression of hormonal activity. Methods for hormone receptor preparation vary greatly, and range from the use of intact cells (as the source of hormone receptor) to the use of purified or solubilized membrane receptors. Receptors isolated from plasma membranes have proved to be of variable stability, and may be damaged during preparation and/or storage. Moreover, since they are present in relatively low concentration in the cell, their preparation in sufficient quantity for use in a radioreceptor assay may present technical problems. In general, there is good correlation between radioreceptor assays and in-vitro bioassays; differences between results from radioreceptor assays and radioimmunoassays are similar to those noted between in-vitro bioassays and radioimmunoassays. The sensitivity of the method is such that normal plasma concentrations of various hormones have been assayed by this technique. (author)

  5. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Timothy M. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Lambert, Iain B. [Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Williams, Andrew [Biostatistics and Epidemiology Division, Safe Environments Programme, 6604B, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Douglas, George R. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Yauk, Carole L. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada)]. E-mail: carole_yauk@hc-sc.gc.ca

    2006-06-25

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.

  6. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    International Nuclear Information System (INIS)

    Singer, Timothy M.; Lambert, Iain B.; Williams, Andrew; Douglas, George R.; Yauk, Carole L.

    2006-01-01

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development

  7. Opportunities and Challenges of Multiplex Assays: A Machine Learning Perspective.

    Science.gov (United States)

    Chen, Junfang; Schwarz, Emanuel

    2017-01-01

    Multiplex assays that allow the simultaneous measurement of multiple analytes in small sample quantities have developed into a widely used technology. Their implementation spans across multiple assay systems and can provide readouts of similar quality as the respective single-plex measures, albeit at far higher throughput. Multiplex assay systems are therefore an important element for biomarker discovery and development strategies but analysis of the derived data can face substantial challenges that may limit the possibility of identifying meaningful biological markers. This chapter gives an overview of opportunities and challenges of multiplexed biomarker analysis, in particular from the perspective of machine learning aimed at identification of predictive biological signatures.

  8. Multiplicative surrogate standard deviation: a group metric for the glycemic variability of individual hospitalized patients.

    Science.gov (United States)

    Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey

    2013-09-01

    Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.

  9. Neural correlates of gait variability in people with multiple sclerosis with fall history.

    Science.gov (United States)

    Kalron, Alon; Allali, Gilles; Achiron, Anat

    2018-05-28

    Investigate the association between step time variability and related brain structures in accordance with fall status in people with multiple sclerosis (PwMS). The study included 225 PwMS. A whole-brain MRI was performed by a high-resolution 3.0-Telsa MR scanner in addition to volumetric analysis based on 3D T1-weighted images using the FreeSurfer image analysis suite. Step time variability was measured by an electronic walkway. Participants were defined as "fallers" (at least two falls during the previous year) and "non-fallers". One hundred and five PwMS were defined as fallers and had a greater step time variability compared to non-fallers (5.6% (S.D.=3.4) vs. 3.4% (S.D.=1.5); p=0.001). MS fallers exhibited a reduced volume in the left caudate and both cerebellum hemispheres compared to non-fallers. By using a linear regression analysis no association was found between gait variability and related brain structures in the total cohort and non-fallers group. However, the analysis found an association between the left hippocampus and left putamen volumes with step time variability in the faller group; p=0.031, 0.048, respectively, controlling for total cranial volume, walking speed, disability, age and gender. Nevertheless, according to the hierarchical regression model, the contribution of these brain measures to predict gait variability was relatively small compared to walking speed. An association between low left hippocampal, putamen volumes and step time variability was found in PwMS with a history of falls, suggesting brain structural characteristics may be related to falls and increased gait variability in PwMS. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Neutron Multiplicity Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine Chiyoko [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    Neutron multiplicity measurements are widely used for nondestructive assay (NDA) of special nuclear material (SNM). When combined with isotopic composition information, neutron multiplicity analysis can be used to estimate the spontaneous fission rate and leakage multiplication of SNM. When combined with isotopic information, the total mass of fissile material can also be determined. This presentation provides an overview of this technique.

  11. Similar or disparate brain patterns? The intra-personal EEG variability of three women with multiple personality disorder.

    Science.gov (United States)

    Lapointe, A R; Crayton, J W; DeVito, R; Fichtner, C G; Konopka, L M

    2006-07-01

    Quantitative EEG was used to assess the intra-personal variability of brain electrical activity for 3 women diagnosed with Multiple Personality Disorder (MPD). Two separate control groups (within-subject and between-subject) were used to test the hypothesis that the intra-personal EEG variability between 2 alters would be less than the interpersonal EEG variability between 2 controls, and similar to the intra-personal EEG variability of a single personality. This hypothesis was partially supported. In general, the 2 EEG records of a MPD subject (alter 1 vs. alter 2) were more different from one another than the 2 EEG records of a single control, but less different from one another than the EEG records of 2 separate controls. Most of the EEG variability between alters involved beta activity in the frontal and temporal lobes.

  12. An optics-based variable-temperature assay system for characterizing thermodynamics of biomolecular reactions on solid support

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Yiyan; Landry, James P.; Zhu, X. D., E-mail: xdzhu@physics.ucdavis.edu [Department of Physics, University of California, One Shields Avenue, Davis, California 95616 (United States); Li, Yanhong; Yu, Hai; Lau, Kam; Huang, Shengshu; Chokhawala, Harshal A.; Chen, Xi [Department of Chemistry, University of California, One Shields Avenue, Davis, California 95616 (United States)

    2013-11-15

    A biological state is equilibrium of multiple concurrent biomolecular reactions. The relative importance of these reactions depends on physiological temperature typically between 10 °C and 50 °C. Experimentally the temperature dependence of binding reaction constants reveals thermodynamics and thus details of these biomolecular processes. We developed a variable-temperature opto-fluidic system for real-time measurement of multiple (400–10 000) biomolecular binding reactions on solid supports from 10 °C to 60 °C within ±0.1 °C. We illustrate the performance of this system with investigation of binding reactions of plant lectins (carbohydrate-binding proteins) with 24 synthetic glycans (i.e., carbohydrates). We found that the lectin-glycan reactions in general can be enthalpy-driven, entropy-driven, or both, and water molecules play critical roles in the thermodynamics of these reactions.

  13. Expected precision of neutron multiplicity measurements of waste drums

    International Nuclear Information System (INIS)

    Ensslin, N.; Krick, M.S.; Menlove, H.O.

    1995-01-01

    DOE facilities are beginning to apply passive neutron multiplicity counting techniques to the assay of plutonium scrap and residues. There is also considerable interest in applying this new measurement technique to 208-liter waste drums. The additional information available from multiplicity counting could flag the presence of shielding materials or improve assay accuracy by correcting for matrix effects such as (α,n) induced fission or detector efficiency variations. The potential for multiplicity analysis of waste drums, and the importance of better detector design, can be estimated by calculating the expected assay precision using a Figure of Merit code for assay variance. This paper reports results obtained as a function of waste drum content and detector characteristics. We find that multiplicity analysis of waste drums is feasible if a high-efficiency neutron counter is used. However, results are significantly poorer if the multiplicity analysis must be used to solve for detection efficiency

  14. The Effects of Multiple Sets of Squats and Jump Squats on Mechanical Variables.

    Science.gov (United States)

    Rossetti, Michael L; Munford, Shawn N; Snyder, Brandon W; Davis, Shala E; Moir, Gavin L

    2017-07-28

    The mechanical responses to two non-ballistic squat and two ballistic jump squat protocols performed over multiple sets were investigated. One protocol from each of the two non-ballistic and ballistic conditions incorporated a pause between the eccentric and concentric phases of the movements in order to determine the influence of the coupling time on the mechanical variables and post-activation potentiation (PAP). Eleven men (age: 21.9 ± 1.8 years; height: 1.79 ± 0.05 m; mass: 87.0 ± 7.4 kg) attended four sessions where they performed multiple sets of squats and jump squats with a load equivalent to 30% 1-repeititon maximum under one of the following conditions: 1) 3 × 4 repetitions of non-ballistic squats (30N-B); 2) 3 × 4 repetitions of non-ballistic squats with a 3-second pause between the eccentric and concentric phases of each repetition (30PN-B); 3) 3 × 4 repetitions of ballistic jump squats (30B); 4) 3 × 4 repetitions of ballistic jump squats with a 3-second pause between the eccentric and concentric phases of each repetition (30PB). Force plates were used to calculate variables including average vertical velocity, average vertical force (GRF), and average power output (PO). Vertical velocities during the ballistic conditions were significantly greater than those attained during the non-ballistic conditions (mean differences: 0.21 - 0.25 m/s, p0.05). Ballistic jump squats may be an effective exercise for developing PO given the high velocities and forces generated in these exercises. Furthermore, the completion of multiple sets of jump squats may induce PAP to enhance PO. The coupling times between the eccentric and concentric phases of the jump squats should be short in order to maximize the GRF and PO across the sets.

  15. Influence of experimental conditions on data variability in the liver comet assay.

    Science.gov (United States)

    Guérard, M; Marchand, C; Plappert-Helbig, U

    2014-03-01

    The in vivo comet assay has increasingly been used for regulatory genotoxicity testing in recent years. While it has been demonstrated that the experimental execution of the assay, for example, electrophoresis or scoring, can have a strong impact on the results; little is known on how initial steps, that is, from tissue sampling during necropsy up to slide preparation, can influence the comet assay results. Therefore, we investigated which of the multitude of steps in processing the liver for the comet assay are most critical. All together eight parameters were assessed by using liver samples of untreated animals. In addition, two of those parameters (temperature and storage time of liver before embedding into agarose) were further investigated in animals given a single oral dose of ethyl methanesulfonate at dose levels of 50, 100, and 200 mg/kg, 3 hr prior to necropsy. The results showed that sample cooling emerged as the predominant influence factor, whereas variations in other elements of the procedure (e.g., size of the liver piece sampled, time needed to process the liver tissue post-mortem, agarose temperature, or time of lysis) seem to be of little relevance. Storing of liver samples of up to 6 hr under cooled conditions did not cause an increase in tail intensity. In contrast, storing the tissue at room temperature, resulted in a considerable time-dependent increase in comet parameters. Copyright © 2013 Wiley Periodicals, Inc.

  16. Multiple-locus variable-number tandem repeat analysis of Neisseria meningitidis yields groupings similar to those obtained by multilocus sequence typing.

    NARCIS (Netherlands)

    Schouls, Leo M; Ende, Arie van der; Damen, Marjolein; Pol, Ingrid van de

    2006-01-01

    We identified many variable-number tandem repeat (VNTR) loci in the genomes of Neisseria meningitidis serogroups A, B, and C and utilized a number of these loci to develop a multiple-locus variable-number tandem repeat analysis (MLVA). Eighty-five N. meningitidis serogroup B and C isolates obtained

  17. Latent Variable Regression 4-Level Hierarchical Model Using Multisite Multiple-Cohorts Longitudinal Data. CRESST Report 801

    Science.gov (United States)

    Choi, Kilchan

    2011-01-01

    This report explores a new latent variable regression 4-level hierarchical model for monitoring school performance over time using multisite multiple-cohorts longitudinal data. This kind of data set has a 4-level hierarchical structure: time-series observation nested within students who are nested within different cohorts of students. These…

  18. Quantifying natural delta variability using a multiple-point geostatistics prior uncertainty model

    Science.gov (United States)

    Scheidt, Céline; Fernandes, Anjali M.; Paola, Chris; Caers, Jef

    2016-10-01

    We address the question of quantifying uncertainty associated with autogenic pattern variability in a channelized transport system by means of a modern geostatistical method. This question has considerable relevance for practical subsurface applications as well, particularly those related to uncertainty quantification relying on Bayesian approaches. Specifically, we show how the autogenic variability in a laboratory experiment can be represented and reproduced by a multiple-point geostatistical prior uncertainty model. The latter geostatistical method requires selection of a limited set of training images from which a possibly infinite set of geostatistical model realizations, mimicking the training image patterns, can be generated. To that end, we investigate two methods to determine how many training images and what training images should be provided to reproduce natural autogenic variability. The first method relies on distance-based clustering of overhead snapshots of the experiment; the second method relies on a rate of change quantification by means of a computer vision algorithm termed the demon algorithm. We show quantitatively that with either training image selection method, we can statistically reproduce the natural variability of the delta formed in the experiment. In addition, we study the nature of the patterns represented in the set of training images as a representation of the "eigenpatterns" of the natural system. The eigenpattern in the training image sets display patterns consistent with previous physical interpretations of the fundamental modes of this type of delta system: a highly channelized, incisional mode; a poorly channelized, depositional mode; and an intermediate mode between the two.

  19. Land use regression modeling of intra-urban residential variability in multiple traffic-related air pollutants

    Directory of Open Access Journals (Sweden)

    Baxter Lisa K

    2008-05-01

    Full Text Available Abstract Background There is a growing body of literature linking GIS-based measures of traffic density to asthma and other respiratory outcomes. However, no consensus exists on which traffic indicators best capture variability in different pollutants or within different settings. As part of a study on childhood asthma etiology, we examined variability in outdoor concentrations of multiple traffic-related air pollutants within urban communities, using a range of GIS-based predictors and land use regression techniques. Methods We measured fine particulate matter (PM2.5, nitrogen dioxide (NO2, and elemental carbon (EC outside 44 homes representing a range of traffic densities and neighborhoods across Boston, Massachusetts and nearby communities. Multiple three to four-day average samples were collected at each home during winters and summers from 2003 to 2005. Traffic indicators were derived using Massachusetts Highway Department data and direct traffic counts. Multivariate regression analyses were performed separately for each pollutant, using traffic indicators, land use, meteorology, site characteristics, and central site concentrations. Results PM2.5 was strongly associated with the central site monitor (R2 = 0.68. Additional variability was explained by total roadway length within 100 m of the home, smoking or grilling near the monitor, and block-group population density (R2 = 0.76. EC showed greater spatial variability, especially during winter months, and was predicted by roadway length within 200 m of the home. The influence of traffic was greater under low wind speed conditions, and concentrations were lower during summer (R2 = 0.52. NO2 showed significant spatial variability, predicted by population density and roadway length within 50 m of the home, modified by site characteristics (obstruction, and with higher concentrations during summer (R2 = 0.56. Conclusion Each pollutant examined displayed somewhat different spatial patterns

  20. Biosensors and multiple mycotoxin analysis

    NARCIS (Netherlands)

    Gaag, B. van der; Spath, S.; Dietrich, H.; Stigter, E.; Boonzaaijer, G.; Osenbruggen, T. van; Koopal, K.

    2003-01-01

    An immunochemical biosensor assay for the detection of multiple mycotoxins in a sample is described.The inhibition assay is designed to measure four different mycotoxins in a single measurement, following extraction, sample clean-up and incubation with an appropriate cocktail of anti-mycotoxin

  1. The impact of pre-analytical variables on the stability of neurofilament proteins in CSF, determined by a novel validated SinglePlex Luminex assay and ELISA.

    Science.gov (United States)

    Koel-Simmelink, Marleen J A; Vennegoor, Anke; Killestein, Joep; Blankenstein, Marinus A; Norgren, Niklas; Korth, Carsten; Teunissen, Charlotte E

    2014-01-15

    Neurofilament (Nf) proteins have been shown to be promising biomarkers for monitoring and predicting disease progression for various neurological diseases. The aim of this study was to evaluate the effects of pre-analytical variables on the concentration of neurofilament heavy (NfH) and neurofilament light (NfL) proteins. For NfH an in-house newly-developed and validated SinglePlex Luminex assay was used; ELISA was used to analyze NfL. For the NfL ELISA assay, the intra- and inter-assay variation was respectively, 1.5% and 16.7%. Analytical performance of the NfH SinglePlex Luminex assay in terms of sensitivity (6.6pg/mL), recovery in cerebrospinal fluid (CSF) (between 90 and 104%), linearity (from 6.6-1250pg/mL), and inter- and intra-assay variation (<8%) were good. Concentrations of both NfL and NfH appeared not negatively affected by blood contamination, repeated freeze-thaw cycles (up to 4), delayed processing (up to 24hours) and during long-term storage at -20°C, 4°C, and room temperature. A decrease in concentration was observed during storage of both neurofilament proteins up to 21days at 37°C, which was significant by day 5. The newly developed NfH SinglePlex Luminex assay has a good sensitivity and is robust. Moreover, both NfH and NfL are stable under the most prevalent pre-analytical variations. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Integrated bioassays in microfluidic devices: botulinum toxin assays.

    Science.gov (United States)

    Mangru, Shakuntala; Bentz, Bryan L; Davis, Timothy J; Desai, Nitin; Stabile, Paul J; Schmidt, James J; Millard, Charles B; Bavari, Sina; Kodukula, Krishna

    2005-12-01

    A microfluidic assay was developed for screening botulinum neurotoxin serotype A (BoNT-A) by using a fluorescent resonance energy transfer (FRET) assay. Molded silicone microdevices with integral valves, pumps, and reagent reservoirs were designed and fabricated. Electrical and pneumatic control hardware were constructed, and software was written to automate the assay protocol and data acquisition. Detection was accomplished by fluorescence microscopy. The system was validated with a peptide inhibitor, running 2 parallel assays, as a feasibility demonstration. The small footprint of each bioreactor cell (0.5 cm2) and scalable fluidic architecture enabled many parallel assays on a single chip. The chip is programmable to run a dilution series in each lane, generating concentration-response data for multiple inhibitors. The assay results showed good agreement with the corresponding experiments done at a macroscale level. Although the system has been developed for BoNT-A screening, a wide variety of assays can be performed on the microfluidic chip with little or no modification.

  3. An integrated probabilistic risk analysis decision support methodology for systems with multiple state variables

    International Nuclear Information System (INIS)

    Sen, P.; Tan, John K.G.; Spencer, David

    1999-01-01

    Probabilistic risk analysis (PRA) methods have been proven to be valuable in risk and reliability analysis. However, a weak link seems to exist between methods for analysing risks and those for making rational decisions. The integrated decision support system (IDSS) methodology presented in this paper attempts to address this issue in a practical manner. In consists of three phases: a PRA phase, a risk sensitivity analysis (SA) phase and an optimisation phase, which are implemented through an integrated computer software system. In the risk analysis phase the problem is analysed by the Boolean representation method (BRM), a PRA method that can deal with systems with multiple state variables and feedback loops. In the second phase the results obtained from the BRM are utilised directly to perform importance and risk SA. In the third phase, the problem is formulated as a multiple objective decision making problem in the form of multiple objective reliability optimisation. An industrial example is included. The resultant solutions of a five objective reliability optimisation are presented, on the basis of which rational decision making can be explored

  4. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    Directory of Open Access Journals (Sweden)

    Ondigo Bartholomew N

    2012-12-01

    Full Text Available Abstract Background Multiplex cytometric bead assay (CBA have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  5. Ecotoxicological Assessment of Aquatic Genotoxicity Using the Comet Assay

    Directory of Open Access Journals (Sweden)

    KHUSNUL YAQIN

    2006-09-01

    Full Text Available Comet assay is a novel biological analysis, which is a sensitive, flexible, simple, rapid, and inexpensive method to assess aquatic genotoxicant. Since Singh and co-workers developed the method in 1988, its use has increased exponentially in various fields. This review discourses on the application of this assay in aquatic ecosystems. Various types of cells from various aquatic organisms have been tested by various genotoxicant both direct- and indirect-acting using the comet assay. The applications of this assay suggest that it is a useful assay to assess aquatic genotoxicants. However, there are some factors, which should be taken into account when using this assay as aquatic ecotoxicological assessment device such as inter-animal and cell variability.

  6. The microculture-kinetic (MiCK) assay: the role of a drug-induced apoptosis assay in drug development and clinical care.

    Science.gov (United States)

    Bosserman, Linda; Prendergast, Franklyn; Herbst, Roy; Fleisher, Martin; Salom, Emery; Strickland, Steven; Raptis, Anastasios; Hallquist, Allan; Perree, Mathieu; Rajurkar, Swapnil; Karimi, Misagh; Rogers, Karl; Davidson, Dirk; Willis, Carl; Penalver, Manuel; Homesley, Howard; Burrell, Matthew; Garrett, Audrey; Rutledge, James; Chernick, Michael; Presant, Cary A

    2012-08-15

    A drug-induced apoptosis assay, termed the microculture-kinetic (MiCK) assay, has been developed. Blinded clinical trials have shown higher response rates and longer survival in groups of patients with acute myelocytic leukemia and epithelial ovarian cancer who have been treated with drugs that show high apoptosis in the MiCK assay. Unblinded clinical trials in multiple tumor types have shown that the assay will be used frequently by clinicians to determine treatment, and when used, results in higher response rates, longer times to relapse, and longer survivals. Model economic analyses suggest possible cost savings in clinical use based on increased generic drug use and single-agent substitution for combination therapies. Two initial studies with drugs in development are promising. The assay may help reduce costs and speed time to drug approval. Correlative studies with molecular biomarkers are planned. This assay may have a role both in personalized clinical therapy and in more efficient drug development. ©2012 AACR.

  7. An Extended TOPSIS Method for Multiple Attribute Decision Making based on Interval Neutrosophic Uncertain Linguistic Variables

    Directory of Open Access Journals (Sweden)

    Said Broumi

    2015-03-01

    Full Text Available The interval neutrosophic uncertain linguistic variables can easily express the indeterminate and inconsistent information in real world, and TOPSIS is a very effective decision making method more and more extensive applications. In this paper, we will extend the TOPSIS method to deal with the interval neutrosophic uncertain linguistic information, and propose an extended TOPSIS method to solve the multiple attribute decision making problems in which the attribute value takes the form of the interval neutrosophic uncertain linguistic variables and attribute weight is unknown. Firstly, the operational rules and properties for the interval neutrosophic variables are introduced. Then the distance between two interval neutrosophic uncertain linguistic variables is proposed and the attribute weight is calculated by the maximizing deviation method, and the closeness coefficients to the ideal solution for each alternatives. Finally, an illustrative example is given to illustrate the decision making steps and the effectiveness of the proposed method.

  8. Characterization of Dutch Staphylococcus aureus from bovine mastitis using a Multiple Locus Variable Number Tandem Repeat Analysis

    NARCIS (Netherlands)

    Ikawaty, R.; Brouwer, E.C.; Jansen, M.D.; Duijkeren, van E.; Mevius, D.J.; Verhoef, J.; Fluit, A.C.

    2009-01-01

    Current typing methods for Staphylococcus aureus have important drawbacks. We evaluated a Multiple Locus Variable Number Tandem Repeat Analysis (MLVA) scheme with 6 loci which lacks most drawbacks on 85 bovine mastitis isolates from The Netherlands. For each locus the number of repeat units (RU) was

  9. Improved detection limit in rapid detection of human enterovirus 71 and coxsackievirus A16 by a novel reverse transcription-isothermal multiple-self-matching-initiated amplification assay.

    Science.gov (United States)

    Ding, Xiong; Nie, Kai; Shi, Lei; Zhang, Yong; Guan, Li; Zhang, Dan; Qi, Shunxiang; Ma, Xuejun

    2014-06-01

    Rapid detection of human enterovirus 71 (EV71) and coxsackievirus A16 (CVA16) is important in the early phase of hand-foot-and-mouth disease (HFMD). In this study, we developed and evaluated a novel reverse transcription-isothermal multiple-self-matching-initiated amplification (RT-IMSA) assay for the rapid detection of EV71 and CVA16 by use of reverse transcriptase, together with a strand displacement DNA polymerase. Real-time RT-IMSA assays using a turbidimeter and visual RT-IMSA assays to detect EV71 and CVA16 were established and completed in 1 h, and the reported corresponding real-time reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assays targeting the same regions of the VP1 gene were adopted as parallel tests. Through testing VP1 RNAs transcribed in vitro, the real-time RT-IMSA assays exhibited better linearity of quantification, with R(2) values of 0.952 (for EV71) and 0.967 (for CVA16), than the real-time RT-LAMP assays, which had R(2) values of 0.803 (for EV71) and 0.904 (for CVA16). Additionally, the detection limits of the real-time RT-IMSA assays (approximately 937 for EV71 and 67 for CVA16 copies/reaction) were higher than those of real-time RT-LAMP assays (approximately 3,266 for EV71 and 430 for CVA16 copies/reaction), and similar results were observed in the visual RT-IMSA assays. The new approaches also possess high specificities for the corresponding targets, with no cross-reactivity observed. In clinical assessment, compared to commercial reverse transcription-quantitative PCR (qRT-PCR) kits, the diagnostic sensitivities of the real-time RT-IMSA assays (96.4% for EV71 and 94.6% for CVA16) were higher than those of the real-time RT-LAMP assays (91.1% for EV71 and 90.8% for CVA16). The visual RT-IMSA assays also exhibited the same results. In conclusion, this proof-of-concept study suggests that the novel RT-IMSA assay is superior to the RT-LAMP assay in terms of detection limit and has the potential to rapidly detect EV71

  10. Heterophilic antibody interference affecting multiple hormone assays: Is it due to rheumatoid factor?

    Science.gov (United States)

    Mongolu, Shiva; Armston, Annie E; Mozley, Erin; Nasruddin, Azraai

    2016-01-01

    Assay interference with heterophilic antibodies has been well described in literature. Rheumatoid factor is known to cause similar interference leading to falsely elevated hormone levels when measured by immunometric methods like enzyme-linked immunosorbent assay (ELISA) or multiplex immunoasays (MIA). We report a case of a 60-year-old male patient with a history of rheumatoid arthritis referred to our endocrine clinic for investigation of hypogonadism and was found to have high serum levels of LH, FSH, SHBG, Prolactin, HCG and TSH. We suspected assay interference and further tests were performed. We used Heteroblock tubes and PEG precipitation to eliminate the interference and the hormone levels post treatment were in the normal range. We believe the interference was caused by high serum levels of rheumatoid factor. Although he was treated with thyroxine for 3 years, we believe he may have been treated inappropriately as his Free T4 level was always normal despite high TSH due to assay interference. Our case illustrates the phenomenon of heterophilic antibody interference likely due to high levels of rheumatoid factor. It is essential for clinicians and endocrinologists in particular to be aware of this possibility when making treatment decisions in these groups of patients.

  11. A quantitative comet infection assay for influenza virus

    Science.gov (United States)

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    Summary The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold increase in sensitivity to ribavirin. AX4 cells (MDCK cells with increased surface concentration of α2–6 sialic acid, the influenza virus receptor) have reduced the comet size variability relative to MDCK cells, making them a better host cell for use in this assay. Because of enhanced antiviral sensitivity in flow-based assays, less drug is required, which could lead to lower reagent costs, reduced cytotoxicity, and fewer false-negative drug screen results. The comet assay also serves as a readout of flow conditions in the well. Observations from comets formed at varying humidity levels indicate a role for evaporation in the mechanism of spontaneous fluid flow in wells. PMID:22155578

  12. Monitoring environmental exposures with semen assays

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Semen studies in humans and animals have yielded extensive and compelling evidence that sperm can be used to assess reproductive potential and diagnose pathology. More recent studies on mutagens and carcinogens both at this and other laboratories suggest that a combination of mouse and human assays can be an efficient, effective approach to monitoring for reproductive hazards in the environment. We are investigating the potential of using variability in sperm morphology and DNA content to quantify and monitor the effects of environmental agents on the human testes. Here we review the status of human and mouse assays for environmental surveillance, discuss the genetic and fertility implications of chemically induced semen changes, and describe the high-speed flow methods being developed to automate sperm assays

  13. The Use of Multiple Correspondence Analysis to Explore Associations between Categories of Qualitative Variables in Healthy Ageing.

    Science.gov (United States)

    Costa, Patrício Soares; Santos, Nadine Correia; Cunha, Pedro; Cotter, Jorge; Sousa, Nuno

    2013-01-01

    The main focus of this study was to illustrate the applicability of multiple correspondence analysis (MCA) in detecting and representing underlying structures in large datasets used to investigate cognitive ageing. Principal component analysis (PCA) was used to obtain main cognitive dimensions, and MCA was used to detect and explore relationships between cognitive, clinical, physical, and lifestyle variables. Two PCA dimensions were identified (general cognition/executive function and memory), and two MCA dimensions were retained. Poorer cognitive performance was associated with older age, less school years, unhealthier lifestyle indicators, and presence of pathology. The first MCA dimension indicated the clustering of general/executive function and lifestyle indicators and education, while the second association was between memory and clinical parameters and age. The clustering analysis with object scores method was used to identify groups sharing similar characteristics. The weaker cognitive clusters in terms of memory and executive function comprised individuals with characteristics contributing to a higher MCA dimensional mean score (age, less education, and presence of indicators of unhealthier lifestyle habits and/or clinical pathologies). MCA provided a powerful tool to explore complex ageing data, covering multiple and diverse variables, showing if a relationship exists and how variables are related, and offering statistical results that can be seen both analytically and visually.

  14. Variability of residual fluxes of suspended sediment in a multiple tidal-inlet system : the Dutch Wadden Sea

    NARCIS (Netherlands)

    Sassi, M.; Duran-Matute, M.; van Kessel, Th.; Gerkema, Th.

    2015-01-01

    In multiple tidal-inlet systems such as the Dutch Wadden Sea, the exchange of sediments between the coastal lagoon and the adjacent sea is controlled by the combined effect of the tides, wind-driven flows, and density-driven flows. We investigate the variability of residual (tidally averaged) fluxes

  15. Within-day variability on short and long walking tests in persons with multiple sclerosis.

    Science.gov (United States)

    Feys, Peter; Bibby, Bo; Romberg, Anders; Santoyo, Carme; Gebara, Benoit; de Noordhout, Benoit Maertens; Knuts, Kathy; Bethoux, Francois; Skjerbæk, Anders; Jensen, Ellen; Baert, Ilse; Vaney, Claude; de Groot, Vincent; Dalgas, Ulrik

    2014-03-15

    To compare within-day variability of short (10 m walking test at usual and fastest speed; 10MWT) and long (2 and 6-minute walking test; 2MWT/6MWT) tests in persons with multiple sclerosis. Observational study. MS rehabilitation and research centers in Europe and US within RIMS (European network for best practice and research in MS rehabilitation). Ambulatory persons with MS (Expanded Disability Status Scale 0-6.5). Subjects of different centers performed walking tests at 3 time points during a single day. 10MWT, 2MWT and 6MWT at fastest speed and 10MWT at usual speed. Ninety-five percent limits of agreement were computed using a random effects model with individual pwMS as random effect. Following this model, retest scores are with 95% certainty within these limits of baseline scores. In 102 subjects, within-day variability was constant in absolute units for the 10MWT, 2MWT and 6MWT at fastest speed (+/-0.26, 0.16 and 0.15m/s respectively, corresponding to +/-19.2m and +/-54 m for the 2MWT and 6MWT) independent on the severity of ambulatory dysfunction. This implies a greater relative variability with increasing disability level, often above 20% depending on the applied test. The relative within-day variability of the 10MWT at usual speed was +/-31% independent of ambulatory function. Absolute values of within-day variability on walking tests at fastest speed were independent of disability level and greater with short compared to long walking tests. Relative within-day variability remained overall constant when measured at usual speed. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  16. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  17. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  18. Measurement of circulating cell-derived microparticles by flow cytometry: sources of variability within the assay.

    Science.gov (United States)

    Ayers, Lisa; Kohler, Malcolm; Harrison, Paul; Sargent, Ian; Dragovic, Rebecca; Schaap, Marianne; Nieuwland, Rienk; Brooks, Susan A; Ferry, Berne

    2011-04-01

    Circulating cell-derived microparticles (MPs) have been implicated in several disease processes and elevated levels are found in many pathological conditions. The detection and accurate measurement of MPs, although attracting widespread interest, is hampered by a lack of standardisation. The aim of this study was to establish a reliable flow cytometric assay to measure distinct subtypes of MPs in disease and to identify any significant causes of variability in MP quantification. Circulating MPs within plasma were identified by their phenotype (platelet, endothelial, leukocyte and annexin-V positivity (AnnV+). The influence of key variables (i.e. time between venepuncture and centrifugation, washing steps, the number of centrifugation steps, freezing/long-term storage and temperature of thawing) on MP measurement were investigated. Increasing time between venepuncture and centrifugation leads to increased MP levels. Washing samples results in decreased AnnV+MPs (P=0.002) and platelet-derived MPs (PMPs) (P=0.002). Double centrifugation of MPs prior to freezing decreases numbers of AnnV+MPs (P=0.0004) and PMPs (P=0.0004). A single freeze thaw cycle of samples led to an increase in AnnV+MPs (P=0.0020) and PMPs (P=0.0039). Long-term storage of MP samples at -80° resulted in decreased MP levels. This study found that minor protocol changes significantly affected MP levels. This is one of the first studies attempting to standardise a method for obtaining and measuring circulating MPs. Standardisation will be essential for successful development of MP technologies, allowing direct comparison of results between studies and leading to a greater understanding of MPs in disease. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  19. Effective implementation of novel MET pharmacodynamic assays in translational studies.

    Science.gov (United States)

    Srivastava, Apurva K; Navas, Tony; Herrick, William G; Hollingshead, Melinda G; Bottaro, Donald P; Doroshow, James H; Parchment, Ralph E

    2017-01-01

    MET tyrosine kinase (TK) dysregulation is significantly implicated in many types of cancer. Despite over 20 years of drug development to target MET in cancers, a pure anti-MET therapeutic has not yet received market approval. The failure of two recently concluded phase III trials point to a major weakness in biomarker strategies to identify patients who will benefit most from MET therapies. The capability to interrogate oncogenic mutations in MET via circulating tumor DNA (ctDNA) provides an important advancement in identification and stratification of patients for MET therapy. However, a wide range in type and frequency of these mutations suggest there is a need to carefully link these mutations to MET dysregulation, at least in proof-of-concept studies. In this review, we elaborate how we can utilize recently developed and validated pharmacodynamic biomarkers of MET not only to show target engagement, but more importantly to quantitatively measure MET dysregulation in tumor tissues. The MET assay endpoints provide evidence of both canonical and non-canonical MET signaling, can be used as "effect markers" to define biologically effective doses (BEDs) for molecularly targeted drugs, confirm mechanism-of-action in testing combination of drugs, and establish whether a diagnostic test is reporting MET dysregulation. We have established standard operating procedures for tumor biopsy collections to control pre-analytical variables that have produced valid results in proof-of-concept studies. The reagents and procedures are made available to the research community for potential implementation on multiple platforms such as ELISA, quantitative immunofluorescence assay (qIFA), and immuno-MRM assays.

  20. Improvement of the R-SWAT-FME framework to support multiple variables and multi-objective functions

    Science.gov (United States)

    Wu, Yiping; Liu, Shu-Guang

    2014-01-01

    Application of numerical models is a common practice in the environmental field for investigation and prediction of natural and anthropogenic processes. However, process knowledge, parameter identifiability, sensitivity, and uncertainty analyses are still a challenge for large and complex mathematical models such as the hydrological/water quality model, Soil and Water Assessment Tool (SWAT). In this study, the previously developed R program language-SWAT-Flexible Modeling Environment (R-SWAT-FME) was improved to support multiple model variables and objectives at multiple time steps (i.e., daily, monthly, and annually). This expansion is significant because there is usually more than one variable (e.g., water, nutrients, and pesticides) of interest for environmental models like SWAT. To further facilitate its easy use, we also simplified its application requirements without compromising its merits, such as the user-friendly interface. To evaluate the performance of the improved framework, we used a case study focusing on both streamflow and nitrate nitrogen in the Upper Iowa River Basin (above Marengo) in the United States. Results indicated that the R-SWAT-FME performs well and is comparable to the built-in auto-calibration tool in multi-objective model calibration. Overall, the enhanced R-SWAT-FME can be useful for the SWAT community, and the methods we used can also be valuable for wrapping potential R packages with other environmental models.

  1. Multiplex High-Throughput Targeted Proteomic Assay To Identify Induced Pluripotent Stem Cells.

    Science.gov (United States)

    Baud, Anna; Wessely, Frank; Mazzacuva, Francesca; McCormick, James; Camuzeaux, Stephane; Heywood, Wendy E; Little, Daniel; Vowles, Jane; Tuefferd, Marianne; Mosaku, Olukunbi; Lako, Majlinda; Armstrong, Lyle; Webber, Caleb; Cader, M Zameel; Peeters, Pieter; Gissen, Paul; Cowley, Sally A; Mills, Kevin

    2017-02-21

    Induced pluripotent stem cells have great potential as a human model system in regenerative medicine, disease modeling, and drug screening. However, their use in medical research is hampered by laborious reprogramming procedures that yield low numbers of induced pluripotent stem cells. For further applications in research, only the best, competent clones should be used. The standard assays for pluripotency are based on genomic approaches, which take up to 1 week to perform and incur significant cost. Therefore, there is a need for a rapid and cost-effective assay able to distinguish between pluripotent and nonpluripotent cells. Here, we describe a novel multiplexed, high-throughput, and sensitive peptide-based multiple reaction monitoring mass spectrometry assay, allowing for the identification and absolute quantitation of multiple core transcription factors and pluripotency markers. This assay provides simpler and high-throughput classification into either pluripotent or nonpluripotent cells in 7 min analysis while being more cost-effective than conventional genomic tests.

  2. Comparison of three multiplex PCR assays for the detection of respiratory viral infections: evaluation of xTAG respiratory virus panel fast assay, RespiFinder 19 assay and RespiFinder SMART 22 assay

    Directory of Open Access Journals (Sweden)

    Dabisch-Ruthe Mareike

    2012-07-01

    Full Text Available Abstract Background A broad spectrum of pathogens is causative for respiratory tract infections, but symptoms are mostly similar. Therefore, the identification of the causative viruses and bacteria is only feasible using multiplex PCR or several monoplex PCR tests in parallel. Methods The analytical sensitivity of three multiplex PCR assays, RespiFinder-19, RespiFinder-SMART-22 and xTAG-Respiratory-Virus-Panel-Fast-Assay (RVP, were compared to monoplex real-time PCR with quantified standardized control material. All assays include the most common respiratory pathogens. Results To compare the analytical sensitivity of the multiplex assays, samples were inoculated with 13 different quantified viruses in the range of 101 to 105 copies/ml. Concordant results were received for rhinovirus, whereas the RVP detected influenzavirus, RSV and hMPV more frequently in low concentrations. The RespiFinder-19 and the RespiFinder-SMART-22 showed a higher analytical sensitivity for adenoviruses and coronaviruses, whereas the RVP was incapable to detect adenovirus and coronavirus in concentrations of 104 copies/ml. The RespiFinder-19 and RespiFinder-SMART-22A did not detect influenzaviruses (104 copies/ml and RSV (103 copies/ml. The detection of all 13 viruses in one sample was only achieved using monoplex PCR. To analyze possible competitive amplification reactions between the different viruses, samples were further inoculated with only 4 different viruses in one sample. Compared to the detection of 13 viruses in parallel, only a few differences were found. The incidence of respiratory viruses was compared in tracheal secretion (TS samples (n = 100 of mechanically ventilated patients in winter (n = 50 and summer (n = 50. In winter, respiratory viruses were detected in 32 TS samples (64% by RespiFinder-19, whereas the detection rate with RVP was only 22%. The most frequent viruses were adenovirus (32% and PIV-2 (20%. Multiple infections were detected

  3. IgD multiple myeloma: Clinical, biological features and prognostic value of the serum free light chain assay.

    Science.gov (United States)

    Djidjik, R; Lounici, Y; Chergeulaïne, K; Berkouk, Y; Mouhoub, S; Chaib, S; Belhani, M; Ghaffor, M

    2015-09-01

    IgD multiple myeloma (MM) is a rare subtype of myeloma, it affects less than 2% of patients with MM. To evaluate the clinical and prognostic attributes of serum free light chains (sFLCs) analysis, we examined 17 cases of IgD MM. From 1998 to 2012, we obtained 1250 monoclonal gammapathies including 590 multiple myeloma and 17 patients had IgD MM. With preponderance of men patients with a mean age at diagnosis of: 59±12years. Patients with IgD MM have a short survival (Median survival=9months). The presenting features included: bone pain (75%), lymphadenopathy (16%), hepatomegaly (25%), splenomegaly (8%), associated AL amyloidosis (6%), renal impairment function (82%), infections (47%), hypercalcemia (37%) and anemia (93%). Serum electrophoresis showed a subtle M-spike (Mean=13.22±10g/L) in all patients associated to a hypogammaglobulinemia. There was an over-representation of Lambda light chain (65%); high serum β2-microglobulin in 91% and Bence Jones proteinuria was identified in 71%. The median rate of sFLCs κ was 19.05mg/L and 296.75mg/L for sFLCs λ. sFLCR was abnormal in 93% of patients and it showed concordance between baseline sFLCR and the survival (P=0.034). The contribution of FLC assay is crucial for the prognosis of patients with IgD MM. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. A model for AGN variability on multiple time-scales

    Science.gov (United States)

    Sartori, Lia F.; Schawinski, Kevin; Trakhtenbrot, Benny; Caplar, Neven; Treister, Ezequiel; Koss, Michael J.; Urry, C. Megan; Zhang, C. E.

    2018-05-01

    We present a framework to link and describe active galactic nuclei (AGN) variability on a wide range of time-scales, from days to billions of years. In particular, we concentrate on the AGN variability features related to changes in black hole fuelling and accretion rate. In our framework, the variability features observed in different AGN at different time-scales may be explained as realisations of the same underlying statistical properties. In this context, we propose a model to simulate the evolution of AGN light curves with time based on the probability density function (PDF) and power spectral density (PSD) of the Eddington ratio (L/LEdd) distribution. Motivated by general galaxy population properties, we propose that the PDF may be inspired by the L/LEdd distribution function (ERDF), and that a single (or limited number of) ERDF+PSD set may explain all observed variability features. After outlining the framework and the model, we compile a set of variability measurements in terms of structure function (SF) and magnitude difference. We then combine the variability measurements on a SF plot ranging from days to Gyr. The proposed framework enables constraints on the underlying PSD and the ability to link AGN variability on different time-scales, therefore providing new insights into AGN variability and black hole growth phenomena.

  5. 32P-postlabeling assay for carcinogen-DNA adducts: description of beta shielding apparatus and semi-automatic spotting and washing devices that facilitate the handling of multiple samples

    International Nuclear Information System (INIS)

    Reddy, M.V.; Blackburn, G.R.

    1990-01-01

    The utilization of the 32 P-postlabeling assay in combination with TLC for the sensitive detection and estimation of aromatic DNA adducts has been increasing. The procedure consists of 32 P-labeling of carcinogen-adducted 3'-nucleotides in the DNA digests using γ- 32 P ATP and polynucleotide kinase, separation of 32 P-labeled adducts by TLC, and their detection by autoradiography. During both 32 P-labeling and initial phases of TLC, a relatively high amount of γ- 32 P ATP is handled when 30 samples are processed simultaneously. We describe the design of acrylic shielding apparatus, semi-automatic TLC spotting devices, and devices for development and washing of multiple TLC plates, which not only provide substantial protection from exposure to 32 P beta radiation, but also allow quick and easy handling of a large number of samples. Specifically, the equipment includes: (i) a multi-tube carousel rack having 15 wells to hold capless Eppendorf tubes and a rotatable lid with an aperture to access individual tubes; (ii) a pipette shielder; (iii) two semi-automatic spotting devices to apply radioactive solutions to TLC plates; (iv) a multi-plate holder for TLC plates; and (v) a mechanical device for washing multiple TLC plates. Item (i) is small enough to be held in one-hand, vortexed, and centrifuged to mix the solutions in each tube while beta radiation is shielded. Items (iii) to (iv) aid in the automation of the assay. (author)

  6. Response variability of different anodal transcranial direct current stimulation intensities across multiple sessions.

    Science.gov (United States)

    Ammann, Claudia; Lindquist, Martin A; Celnik, Pablo A

    It is well known that transcranial direct current stimulation (tDCS) is capable of modulating corticomotor excitability. However, a source of growing concern has been the observed inter- and intra-individual variability of tDCS-responses. Recent studies have assessed whether individuals respond in a predictable manner across repeated sessions of anodal tDCS (atDCS). The findings of these investigations have been inconsistent, and their methods have some limitations (i.e. lack of sham condition or testing only one tDCS intensity). To study inter- and intra-individual variability of atDCS effects at two different intensities on primary motor cortex (M1) excitability. Twelve subjects participated in a crossover study testing 7-min atDCS over M1 in three separate conditions (2 mA, 1 mA, sham) each repeated three times separated by 48 h. Motor evoked potentials were recorded before and after stimulation (up to 30min). Time of testing was maintained consistent within participants. To estimate the reliability of tDCS effects across sessions, we calculated the Intra-class Correlation Coefficient (ICC). AtDCS at 2 mA, but not 1 mA, significantly increased cortical excitability at the group level in all sessions. The overall ICC revealed fair to high reliability of tDCS effects for multiple sessions. Given that the distribution of responses showed important variability in the sham condition, we established a Sham Variability-Based Threshold to classify responses and to track individual changes across sessions. Using this threshold an intra-individual consistent response pattern was then observed only for the 2 mA condition. 2 mA anodal tDCS results in consistent intra- and inter-individual increases of M1 excitability. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Reproducibility of Interferon Gamma (IFN-γ) Release Assays. A Systematic Review

    Science.gov (United States)

    Tagmouti, Saloua; Slater, Madeline; Benedetti, Andrea; Kik, Sandra V.; Banaei, Niaz; Cattamanchi, Adithya; Metcalfe, John; Dowdy, David; van Zyl Smit, Richard; Dendukuri, Nandini

    2014-01-01

    Rationale: Interferon gamma (IFN-γ) release assays for latent tuberculosis infection result in a larger-than-expected number of conversions and reversions in occupational screening programs, and reproducibility of test results is a concern. Objectives: Knowledge of the relative contribution and extent of the individual sources of variability (immunological, preanalytical, or analytical) could help optimize testing protocols. Methods: We performed a systematic review of studies published by October 2013 on all potential sources of variability of commercial IFN-γ release assays (QuantiFERON-TB Gold In-Tube and T-SPOT.TB). The included studies assessed test variability under identical conditions and under different conditions (the latter both overall and stratified by individual sources of variability). Linear mixed effects models were used to estimate within-subject SD. Measurements and Main Results: We identified a total of 26 articles, including 7 studies analyzing variability under the same conditions, 10 studies analyzing variability with repeat testing over time under different conditions, and 19 studies reporting individual sources of variability. Most data were on QuantiFERON (only three studies on T-SPOT.TB). A considerable number of conversions and reversions were seen around the manufacturer-recommended cut-point. The estimated range of variability of IFN-γ response in QuantiFERON under identical conditions was ±0.47 IU/ml (coefficient of variation, 13%) and ±0.26 IU/ml (30%) for individuals with an initial IFN-γ response in the borderline range (0.25–0.80 IU/ml). The estimated range of variability in noncontrolled settings was substantially larger (±1.4 IU/ml; 60%). Blood volume inoculated into QuantiFERON tubes and preanalytic delay were identified as key sources of variability. Conclusions: This systematic review shows substantial variability with repeat IFN-γ release assays testing even under identical conditions, suggesting that reversions

  8. Investigating Factorial Invariance of Latent Variables Across Populations When Manifest Variables Are Missing Completely.

    Science.gov (United States)

    Widaman, Keith F; Grimm, Kevin J; Early, Dawnté R; Robins, Richard W; Conger, Rand D

    2013-07-01

    Difficulties arise in multiple-group evaluations of factorial invariance if particular manifest variables are missing completely in certain groups. Ad hoc analytic alternatives can be used in such situations (e.g., deleting manifest variables), but some common approaches, such as multiple imputation, are not viable. At least 3 solutions to this problem are viable: analyzing differing sets of variables across groups, using pattern mixture approaches, and a new method using random number generation. The latter solution, proposed in this article, is to generate pseudo-random normal deviates for all observations for manifest variables that are missing completely in a given sample and then to specify multiple-group models in a way that respects the random nature of these values. An empirical example is presented in detail comparing the 3 approaches. The proposed solution can enable quantitative comparisons at the latent variable level between groups using programs that require the same number of manifest variables in each group.

  9. Multiplexing a high-throughput liability assay to leverage efficiencies.

    Science.gov (United States)

    Herbst, John; Anthony, Monique; Stewart, Jeremy; Connors, David; Chen, Taosheng; Banks, Martyn; Petrillo, Edward W; Agler, Michele

    2009-06-01

    In order to identify potential cytochrome P-450 3A4 (drug-metabolizing enzyme) inducers at an early stage of the drug discovery process, a cell-based transactivation high-throughput luciferase reporter assay for the human pregnane X receptor (PXR) in HepG2 cells has been implemented and multiplexed with a viability end point for data interpretation, as part of a Lead Profiling portfolio of assays. As a routine part of Lead Profiling operations, assays are periodically evaluated for utility as well as for potential improvements in technology or process. We used a recent evaluation of our PXR-transactivation assay as a model for the application of Lean Thinking-based process analysis to lab-bench assay optimization and automation. This resulted in the development of a 384-well multiplexed homogeneous assay simultaneously detecting PXR transactivation and HepG2 cell cytotoxicity. In order to multiplex fluorescent and luminescent read-outs, modifications to each assay were necessary, which included optimization of multiple assay parameters such as cell density, plate type, and reagent concentrations. Subsequently, a set of compounds including known cytotoxic compounds and PXR inducers were used to validate the multiplexed assay. Results from the multiplexed assay correlate well with those from the singleplexed assay formats measuring PXR transactivation and viability separately. Implementation of the multiplexed assay for routine compound profiling provides improved data quality, sample conservation, cost savings, and resource efficiencies.

  10. Specificity of B-type natriuretic peptide assays

    DEFF Research Database (Denmark)

    Saenger, Amy K.; Rodriguez-Fraga, Olaia; Ler, Ranka

    2017-01-01

    BACKGROUND: B-type natriuretic peptides (BNPs) are used clinically to diagnose and monitor heart failure and are present in the circulation as multiple proBNP-derived fragments. We investigated the specificity of BNP immunoassays with glycosylated and nonglycosylated BNP, N-terminal proBNP (NT......-proBNP), and proBNP peptides to probe the cross-reactivity of each assay. METHODS: Nine B-type natriuretic peptides were studied, including synthetic and recombinant BNP (Shionogi, Scios, Mayo), human and synthetic glycosylated and nonglycosylated NT-proBNP (HyTest, Roche Diagnostics), and human glycosylated......-Rad, Goetze] were evaluated. Specificity was assessed by calculating the recovery between baseline and peptide-spiked human plasma pools at target concentrations of 100 ng/L BNP, 300 ng/L proBNP, or 450 ng/L NT-proBNP. All assays were performed in duplicate. RESULTS: BNP and NT-proBNP assays demonstrated...

  11. Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants

    OpenAIRE

    Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki

    2015-01-01

    Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates f...

  12. Multiple-locus variable-number tandem-repeat analysis of pathogenic Yersinia enterocolitica in China.

    Directory of Open Access Journals (Sweden)

    Xin Wang

    Full Text Available The predominant bioserotypes of pathogenic Yersinia enterocolitica in China are 2/O: 9 and 3/O: 3; no pathogenic O: 8 strains have been found to date. Multiple-Locus Variable-Number Tandem-Repeat Analysis (MLVA based on seven loci was able to distinguish 104 genotypes among 218 pathogenic Y. enterocolitica isolates in China and from abroad, showing a high resolution. The major pathogenic serogroups in China, O: 3 and O: 9, were divided into two clusters based on MLVA genotyping. The different distribution of Y. enterocolitica MLVA genotypes maybe due to the recent dissemination of specific clones of 2/O: 9 and 3/O: 3 strains in China. MLVA was a helpful tool for bacterial pathogen surveillance and investigation of pathogenic Y. enterocolitica outbreaks.

  13. Microsphere Suspension Array Assays for Detection and Differentiation of Hendra and Nipah Viruses

    Directory of Open Access Journals (Sweden)

    Adam J. Foord

    2013-01-01

    Full Text Available Microsphere suspension array systems enable the simultaneous fluorescent identification of multiple separate nucleotide targets in a single reaction. We have utilized commercially available oligo-tagged microspheres (Luminex MagPlex-TAG to construct and evaluate multiplexed assays for the detection and differentiation of Hendra virus (HeV and Nipah virus (NiV. Both these agents are bat-borne zoonotic paramyxoviruses of increasing concern for veterinary and human health. Assays were developed targeting multiple sites within the nucleoprotein (N and phosphoprotein (P encoding genes. The relative specificities and sensitivities of the assays were determined using reference isolates of each virus type, samples from experimentally infected horses, and archival veterinary diagnostic submissions. Results were assessed in direct comparison with an established qPCR. The microsphere array assays achieved unequivocal differentiation of HeV and NiV and the sensitivity of HeV detection was comparable to qPCR, indicating high analytical and diagnostic specificity and sensitivity.

  14. Imported brucellosis in Denmark: Molecular identification and multiple-locus variable number tandem repeat analysis (MLVA) genotyping of the bacteria

    DEFF Research Database (Denmark)

    Aftab, H.; Dargis, R.; Christensen, J. J.

    2011-01-01

    A polymerase chain reaction was used to identify Brucella species isolated from humans in Denmark. Consecutive analysis of referred bacteria and re-examination of historical isolates identified all as Brucella melitensis. Multiple-locus variable number tandem repeat analysis (MLVA) placed...... the isolates in the previously defined 'East Mediterranean' B. melitensis group....

  15. Whole blood microculture assay of human lymphocyte function.

    Science.gov (United States)

    Pauly, J L; Han, T

    1976-11-01

    A whole blood microculture assay is described for measuring lymphocyte reactivity to mitogenic and antigenic stimulants. This assay employs heparinized whole blood, serum-free culture medium, microtiter plates, and a Multiple Automated Sample Harvester (MASH). When this assay is compared to other leukocyte assays, its major advantages include (1) the utilization of fewer lymphocytes per microculture, thuus reducing the amount of blood required per test while increasing the number of test agents and replicate cultures which can be employed in any given experiment; (2) the conservation of mitogens, antigens, drugs, enzymes, hormones, lymphokines, and other test agents, some of which are either expensive of difficult to prepare in large quantities; (3) the elimination of lymphocyte isolation and purification procedures which may disrupt the relative proportion of T cells, B cells and antigen-processing cells; and (4) the application of an automated harvester which simplifies and expedites procedures required for processing cells for liquid scintillation counting.

  16. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  18. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  19. Non-destructive isotopic uranium assay by multiple delayed neutron measurements

    International Nuclear Information System (INIS)

    Papadopoulos, N.N.; Tsagas, N.F.

    1991-01-01

    The high accuracy and precision required in nuclear safeguards measurements can be achieved by an improved neutron activation technique based on multiple delayed fission neutron counting under various experimental conditions. For the necessary ultrahigh counting statistics required, cyclic activation of multiple subsamples has been applied. The home-made automated flexible analytical system with neutron flux and spectrum differentiation by irradiation position adjustment and cadmium screening, permits the non-destructive determination of the U235 abundance and the total U element concentration needed in nuclear safeguards sample analysis, with a high throughout and a low operational cost. Careful experimental optimization led to considerable improvement of the results

  20. Use of multiple-locus variable-number tandem-repeats analysis (MLVA) typing to characterize Salmonella Typhimurium DT41 broiler breeder infections

    DEFF Research Database (Denmark)

    Litrup, E.; Christensen, H.; Nordentoft, Steen

    2010-01-01

    To characterize isolates of Salmonella Typhimurium DT41 obtained from infected flocks of broiler breeders by multiple-locus variable-number tandem-repeats analysis (MLVA) and compare results with a diverse strain collection from Germany and United Kingdom and isolates from Danish patients. A total...

  1. Molecular Methods for Typing of Streptococcus agalactiae with Special Emphasis on the Development and Validation of a Multi-Locus Variable Number of Tandem Repeats Assay (MLVA)

    OpenAIRE

    Radtke, Andreas

    2012-01-01

    Molekylære metoder for typing av Streptococcus agalactiae med særlig vektlegging av utvikling og validering av et multi-locus variable number of tandem repeats assay (MLVA) Sammendraget: Streptococcus agalactiae eller gruppe B streptokokker (GBS) forårsaker livsfarlige infeksjoner hos nyfødte, gravide eller voksne med kroniske sykdommer. Den forårsaker også jurbetennelse i storfe. Typing av GBS gir innblikk i bakteriens epidemiologi og dens fylogenetiske slektskap. Ulike deler av bakterie...

  2. Acute Responses of a Physical Training Session with a Nintendo Wii on Hemodynamic Variables of an Individual with Multiple Sclerosis.

    Science.gov (United States)

    Monteiro Junior, Renato Sobral; Dantas, Aretha; de Souza, Cíntia Pereira; da Silva, Elirez Bezerra

    2012-12-01

    Multiple sclerosis is a neurological illness that decreases motor functions. This disease can cause weakness of cardiorespiratory muscles and impaired functional capacity and quality of life. Therefore it requires preventive treatments. This study investigated the acute responses of a virtual physical training session with the Nintendo(®) (Kyoto, Japan) Wii™ on hemodynamic variables of an individual with multiple sclerosis (relapsing-remitting). A 34-year-old man with multiple sclerosis with previous experience in aerobic, strength, and functional training (2 years) was tested. His Expanded Disability Status Scale was 2.5. We compared the heart rate, blood pressure, and double product obtained at rest and during (heart rate) and after the Nintendo Wii games "Boxing" and "Sword Play." In rest, the variables were measured in the supine position. Our results showed positive hemodynamic alterations after execution of both games. The peak of heart rate was 121 beats per minute (65% of maximal heart rate) and 104 beats per minute (56% of maximal heart rate) for "Boxing" and "Sword Play," respectively. The training session with "Boxing" was able to stimulate the heart rate to achieve the recommended values for the maintenance of physical fitness in accordance with the American College of Sports Medicine guidelines. We conclude that an exercise training program with the Nintendo Wii may improve physical fitness in people with multiple sclerosis. Moreover, these activities could improve affective status and perhaps maintain the individual engaged at treatment program.

  3. A Simple Assay to Screen Antimicrobial Compounds Potentiating the Activity of Current Antibiotics

    Directory of Open Access Journals (Sweden)

    Junaid Iqbal

    2013-01-01

    Full Text Available Antibiotic resistance continues to pose a significant problem in the management of bacterial infections, despite advances in antimicrobial chemotherapy and supportive care. Here, we suggest a simple, inexpensive, and easy-to-perform assay to screen antimicrobial compounds from natural products or synthetic chemical libraries for their potential to work in tandem with the available antibiotics against multiple drug-resistant bacteria. The aqueous extract of Juglans regia tree bark was tested against representative multiple drug-resistant bacteria in the aforementioned assay to determine whether it potentiates the activity of selected antibiotics. The aqueous extract of J. regia bark was added to Mueller-Hinton agar, followed by a lawn of multiple drug-resistant bacteria, Salmonella typhi or enteropathogenic E. coli. Next, filter paper discs impregnated with different classes of antibiotics were placed on the agar surface. Bacteria incubated with extract or antibiotics alone were used as controls. The results showed a significant increase (>30% in the zone of inhibition around the aztreonam, cefuroxime, and ampicillin discs compared with bacteria incubated with the antibiotics/extract alone. In conclusion, our assay is able to detect either synergistic or additive action of J. regia extract against multiple drug-resistant bacteria when tested with a range of antibiotics.

  4. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    Science.gov (United States)

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (assay variability assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  5. Analysis of Brassica oleracea early stage abiotic stress responses reveals tolerance in multiple crop types and for multiple sources of stress.

    Science.gov (United States)

    Beacham, Andrew M; Hand, Paul; Pink, David Ac; Monaghan, James M

    2017-12-01

    Brassica oleracea includes a number of important crop types such as cabbage, cauliflower, broccoli and kale. Current climate conditions and weather patterns are causing significant losses in these crops, meaning that new cultivars with improved tolerance of one or more abiotic stress types must be sought. In this study, genetically fixed B. oleracea lines belonging to a Diversity Fixed Foundation Set (DFFS) were assayed for their response to seedling stage-imposed drought, flood, salinity, heat and cold stress. Significant (P ≤ 0.05) variation in stress tolerance response was found for each stress, for each of four measured variables (relative fresh weight, relative dry weight, relative leaf number and relative plant height). Lines tolerant to multiple stresses were found to belong to several different crop types. There was no overall correlation between the responses to the different stresses. Abiotic stress tolerance was identified in multiple B. oleracea crop types, with some lines exhibiting resistance to multiple stresses. For each stress, no one crop type appeared significantly more or less tolerant than others. The results are promising for the development of more environmentally robust lines of different B. oleracea crops by identifying tolerant material and highlighting the relationship between responses to different stresses. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  6. An analytical approach to reduce between-plate variation in multiplex assays that measure antibodies to Plasmodium falciparum antigens.

    Science.gov (United States)

    Fang, Rui; Wey, Andrew; Bobbili, Naveen K; Leke, Rose F G; Taylor, Diane Wallace; Chen, John J

    2017-07-17

    Antibodies play an important role in immunity to malaria. Recent studies show that antibodies to multiple antigens, as well as, the overall breadth of the response are associated with protection from malaria. Yet, the variability and reliability of antibody measurements against a combination of malarial antigens using multiplex assays have not been well characterized. A normalization procedure for reducing between-plate variation using replicates of pooled positive and negative controls was investigated. Sixty test samples (30 from malaria-positive and 30 malaria-negative individuals), together with five pooled positive-controls and two pooled negative-controls, were screened for antibody levels to 9 malarial antigens, including merozoite antigens (AMA1, EBA175, MSP1, MSP2, MSP3, MSP11, Pf41), sporozoite CSP, and pregnancy-associated VAR2CSA. The antibody levels were measured in triplicate on each of 3 plates, and the experiments were replicated on two different days by the same technician. The performance of the proposed normalization procedure was evaluated with the pooled controls for the test samples on both the linear and natural-log scales. Compared with data on the linear scale, the natural-log transformed data were less skewed and reduced the mean-variance relationship. The proposed normalization procedure using pooled controls on the natural-log scale significantly reduced between-plate variation. For malaria-related research that measure antibodies to multiple antigens with multiplex assays, the natural-log transformation is recommended for data analysis and use of the normalization procedure with multiple pooled controls can improve the precision of antibody measurements.

  7. Assay of low-enriched uranium using spontaneous fission neutrons

    International Nuclear Information System (INIS)

    Zucker, M.S.; Fainberg, A.

    1980-01-01

    Low-enriched uranium oxide in bulk containers can be assayed for safeguards purposes, using the neutrons from spontaneous fission of 238 U as a signature, to complement enrichment and mass measurement. The penetrability of the fast fission neutrons allows the inner portion of bulk samples to register. The measurement may also be useful for measuring moisture content, of significance in process control. The apparatus used can be the same as for neutron correlation counting for Pu assay. The neutron multiplication observed in 238 U is of intrinsic interest

  8. Towards a More Biologically-meaningful Climate Characterization: Variability in Space and Time at Multiple Scales

    Science.gov (United States)

    Christianson, D. S.; Kaufman, C. G.; Kueppers, L. M.; Harte, J.

    2013-12-01

    Sampling limitations and current modeling capacity justify the common use of mean temperature values in summaries of historical climate and future projections. However, a monthly mean temperature representing a 1-km2 area on the landscape is often unable to capture the climate complexity driving organismal and ecological processes. Estimates of variability in addition to mean values are more biologically meaningful and have been shown to improve projections of range shifts for certain species. Historical analyses of variance and extreme events at coarse spatial scales, as well as coarse-scale projections, show increasing temporal variability in temperature with warmer means. Few studies have considered how spatial variance changes with warming, and analysis for both temporal and spatial variability across scales is lacking. It is unclear how the spatial variability of fine-scale conditions relevant to plant and animal individuals may change given warmer coarse-scale mean values. A change in spatial variability will affect the availability of suitable habitat on the landscape and thus, will influence future species ranges. By characterizing variability across both temporal and spatial scales, we can account for potential bias in species range projections that use coarse climate data and enable improvements to current models. In this study, we use temperature data at multiple spatial and temporal scales to characterize spatial and temporal variability under a warmer climate, i.e., increased mean temperatures. Observational data from the Sierra Nevada (California, USA), experimental climate manipulation data from the eastern and western slopes of the Rocky Mountains (Colorado, USA), projected CMIP5 data for California (USA) and observed PRISM data (USA) allow us to compare characteristics of a mean-variance relationship across spatial scales ranging from sub-meter2 to 10,000 km2 and across temporal scales ranging from hours to decades. Preliminary spatial analysis at

  9. Characterization of a method for quantitating food consumption for mutation assays in Drosophila

    International Nuclear Information System (INIS)

    Thompson, E.D.; Reeder, B.A.; Bruce, R.D.

    1991-01-01

    Quantitation of food consumption is necessary when determining mutation responses to multiple chemical exposures in the sex-linked recessive lethal assay in Drosophila. One method proposed for quantitating food consumption by Drosophila is to measure the incorporation of 14C-leucine into the flies during the feeding period. Three sources of variation in the technique of Thompson and Reeder have been identified and characterized. First, the amount of food consumed by individual flies differed by almost 30% in a 24 hr feeding period. Second, the variability from vial to vial (each containing multiple flies) was around 15%. Finally, the amount of food consumed in identical feeding experiments performed over the course of 1 year varied nearly 2-fold. The use of chemical consumption values in place of exposure levels provided a better means of expressing the combined mutagenic response. In addition, the kinetics of food consumption over a 3 day feeding period for exposures to cyclophosphamide which produce lethality were compared to non-lethal exposures. Extensive characterization of lethality induced by exposures to cyclophosphamide demonstrate that the lethality is most likely due to starvation, not chemical toxicity

  10. The impact of gate width setting and gate utilization factors on plutonium assay in passive correlated neutron counting

    International Nuclear Information System (INIS)

    Henzlova, D.; Menlove, H.O.; Croft, S.; Favalli, A.; Santi, P.

    2015-01-01

    In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated

  11. The impact of gate width setting and gate utilization factors on plutonium assay in passive correlated neutron counting

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Menlove, H.O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Croft, S. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Favalli, A.; Santi, P. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2015-10-11

    In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.

  12. Decoupling Solar Variability and Instrument Trends Using the Multiple Same-Irradiance-Level (MuSIL) Analysis Technique

    Science.gov (United States)

    Woods, Thomas N.; Eparvier, Francis G.; Harder, Jerald; Snow, Martin

    2018-05-01

    The solar spectral irradiance (SSI) dataset is a key record for studying and understanding the energetics and radiation balance in Earth's environment. Understanding the long-term variations of the SSI over timescales of the 11-year solar activity cycle and longer is critical for many Sun-Earth research topics. Satellite measurements of the SSI have been made since the 1970s, most of them in the ultraviolet, but recently also in the visible and near-infrared. A limiting factor for the accuracy of previous solar variability results is the uncertainties for the instrument degradation corrections, which need fairly large corrections relative to the amount of solar cycle variability at some wavelengths. The primary objective of this investigation has been to separate out solar cycle variability and any residual uncorrected instrumental trends in the SSI measurements from the Solar Radiation and Climate Experiment (SORCE) mission and the Thermosphere, Mesosphere, Ionosphere, Energetic, and Dynamics (TIMED) mission. A new technique called the Multiple Same-Irradiance-Level (MuSIL) analysis has been developed, which examines an SSI time series at different levels of solar activity to provide long-term trends in an SSI record, and the most common result is a downward trend that most likely stems from uncorrected instrument degradation. This technique has been applied to each wavelength in the SSI records from SORCE (2003 - present) and TIMED (2002 - present) to provide new solar cycle variability results between 27 nm and 1600 nm with a resolution of about 1 nm at most wavelengths. This technique, which was validated with the highly accurate total solar irradiance (TSI) record, has an estimated relative uncertainty of about 5% of the measured solar cycle variability. The MuSIL results are further validated with the comparison of the new solar cycle variability results from different solar cycles.

  13. Body fluid markers to monitor multiple sclerosis: The assays and the challenges

    NARCIS (Netherlands)

    Laman, J.D.; Thompson, E.J.; Kappos, L.

    1998-01-01

    The need for reliable markers of disease activity in multiple sclerosis (MS) to better guide basic research, diagnosis, treatment, and monitoring of therapy is well-recognized. A recent European Charcot Foundation Symposium (Body fluid markers for course and activity of disease in multiple sclerosis

  14. Variability in large-scale wind power generation

    DEFF Research Database (Denmark)

    Kiviluoma, Juha; Holttinen, Hannele; Weir, David

    2016-01-01

    The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net ...... with well-dispersed wind power. Copyright © 2015 John Wiley & Sons, Ltd....

  15. Systematic random sampling of the comet assay.

    Science.gov (United States)

    McArt, Darragh G; Wasson, Gillian R; McKerr, George; Saetzler, Kurt; Reed, Matt; Howard, C Vyvyan

    2009-07-01

    The comet assay is a technique used to quantify DNA damage and repair at a cellular level. In the assay, cells are embedded in agarose and the cellular content is stripped away leaving only the DNA trapped in an agarose cavity which can then be electrophoresed. The damaged DNA can enter the agarose and migrate while the undamaged DNA cannot and is retained. DNA damage is measured as the proportion of the migratory 'tail' DNA compared to the total DNA in the cell. The fundamental basis of these arbitrary values is obtained in the comet acquisition phase using fluorescence microscopy with a stoichiometric stain in tandem with image analysis software. Current methods deployed in such an acquisition are expected to be both objectively and randomly obtained. In this paper we examine the 'randomness' of the acquisition phase and suggest an alternative method that offers both objective and unbiased comet selection. In order to achieve this, we have adopted a survey sampling approach widely used in stereology, which offers a method of systematic random sampling (SRS). This is desirable as it offers an impartial and reproducible method of comet analysis that can be used both manually or automated. By making use of an unbiased sampling frame and using microscope verniers, we are able to increase the precision of estimates of DNA damage. Results obtained from a multiple-user pooled variation experiment showed that the SRS technique attained a lower variability than that of the traditional approach. The analysis of a single user with repetition experiment showed greater individual variances while not being detrimental to overall averages. This would suggest that the SRS method offers a better reflection of DNA damage for a given slide and also offers better user reproducibility.

  16. Assessing population and environmental effects on thermal resistance in Drosophila melanogaster using ecologically relevant assays

    DEFF Research Database (Denmark)

    Overgaard, Johannes; Hoffmann, Ary A; Kristensen, Torsten Nygård

    2011-01-01

    To make laboratory studies of thermal resistance in ectotherms more ecologically relevant, temperature changes that reflect conditions experienced by individuals in nature should be used. Here we describe an assay that is useful for quantifying multiple measures of thermal resistance of individual...... adult flies. We use this approach to assess upper and lower thermal limits and functional thermal scope for Drosophila melanogaster and also show that the method can be used to (1) detect a previously described latitudinal cline for cold tolerance in D. melanogaster populations collected along the east...... thermal environments have wider thermal limits compared to those from the less variable tropics, at least when flies were reared under constant temperature conditions and (4) demonstrate that different measures of cold resistance are often not strongly correlated. Based on our findings, we suggest...

  17. Staphylococcus aureus from 152 cases of bovine, ovine and caprine mastitis investigated by Multiple-locus variable number of tandem repeat analysis (MLVA).

    Science.gov (United States)

    Bergonier, Dominique; Sobral, Daniel; Feßler, Andrea T; Jacquet, Eric; Gilbert, Florence B; Schwarz, Stefan; Treilles, Michaël; Bouloc, Philippe; Pourcel, Christine; Vergnaud, Gilles

    2014-10-02

    Staphylococcus aureus is one of the main etiological agents of mastitis in ruminants. In the present retrospective study, we evaluated the potential interest of a previously described automated multiple loci Variable Number of Tandem Repeats (VNTR) Assay (MLVA) comprising 16 loci as a first line tool to investigate the population structure of S. aureus from mastitis. We determined the genetic diversity of S. aureus strains from cases of clinical and subclinical mastitis in dairy cattle (n = 118, of which 16 were methicillin-resistant), sheep (n = 18) and goats (n = 16). The 152 strains could be subdivided into 115 MLVA genotypes (including 14 genotypes for the ovine strains and 15 genotypes for the caprine strains). This corresponds to a discriminatory index (D) value of 0.9936. Comparison with published MLVA data obtained using the same protocol applied to strains from diverse human and animal origins revealed a low number (8.5%) of human-related MLVA genotypes among the present collection. Eighteen percent of the S. aureus mastitis collection belonged to clonal complexes apparently not associated with other pathological conditions. Some of them displayed a relatively low level of diversity in agreement with a restricted ecological niche. These findings provide arguments suggesting that specific S. aureus lineages particularly adapted to ruminant mammary glands have emerged and that MLVA is a convenient tool to provide a broad overview of the population, owing to the availability via internet of databases compiling published MLVA genotypes.

  18. A national quality control scheme for serum HGH assays

    International Nuclear Information System (INIS)

    Hunter, W.M.; McKenzie, I.

    1979-01-01

    In the autumn of 1975 the Supraregional Assay Service established a Quality Control Sub-Committee and the intra-laboratory QC Scheme for Growth Hormone (HGH) assays which is described here has served, in many respects, as a pilot scheme for protein RIA. Major improvements in accuracy, precision and between-laboratory agreement can be brought about by intensively interactive quality control schemes. A common standard is essential and should consist of ampoules used for one or only a small number of assays. Accuracy and agreement were not good enough to allow the overall means to serve as target values but a group of 11 laboratories were sufficiently accurate to provide a 'reference group mean' to so serve. Gross non-specificity was related to poor assay design and was quickly eliminated. Within-laboratory between-batch variability was much worse than that normally claimed for simple protein hormone RIA. A full report on this Scheme will appear shortly in Annals of Clinical Biochemistry. (Auth.)

  19. Using multiple biomarkers and determinants to obtain a better measurement of oxidative stress: a latent variable structural equation model approach.

    Science.gov (United States)

    Eldridge, Ronald C; Flanders, W Dana; Bostick, Roberd M; Fedirko, Veronika; Gross, Myron; Thyagarajan, Bharat; Goodman, Michael

    2017-09-01

    Since oxidative stress involves a variety of cellular changes, no single biomarker can serve as a complete measure of this complex biological process. The analytic technique of structural equation modeling (SEM) provides a possible solution to this problem by modelling a latent (unobserved) variable constructed from the covariance of multiple biomarkers. Using three pooled datasets, we modelled a latent oxidative stress variable from five biomarkers related to oxidative stress: F 2 -isoprostanes (FIP), fluorescent oxidation products, mitochondrial DNA copy number, γ-tocopherol (Gtoc) and C-reactive protein (CRP, an inflammation marker closely linked to oxidative stress). We validated the latent variable by assessing its relation to pro- and anti-oxidant exposures. FIP, Gtoc and CRP characterized the latent oxidative stress variable. Obesity, smoking, aspirin use and β-carotene were statistically significantly associated with oxidative stress in the theorized directions; the same exposures were weakly and inconsistently associated with the individual biomarkers. Our results suggest that using SEM with latent variables decreases the biomarker-specific variability, and may produce a better measure of oxidative stress than do single variables. This methodology can be applied to similar areas of research in which a single biomarker is not sufficient to fully describe a complex biological phenomenon.

  20. Mixture models for single-cell assays with applications to vaccine studies

    OpenAIRE

    Finak, Greg; McDavid, Andrew; Chattopadhyay, Pratip; Dominguez, Maria; De Rosa, Steve; Roederer, Mario; Gottardo, Raphael

    2013-01-01

    Blood and tissue are composed of many functionally distinct cell subsets. In immunological studies, these can be measured accurately only using single-cell assays. The characterization of these small cell subsets is crucial to decipher system-level biological changes. For this reason, an increasing number of studies rely on assays that provide single-cell measurements of multiple genes and proteins from bulk cell samples. A common problem in the analysis of such data is to identify biomarkers...

  1. Multiplexed profiling of GPCR activities by combining split TEV assays and EXT-based barcoded readouts.

    Science.gov (United States)

    Galinski, Sabrina; Wichert, Sven P; Rossner, Moritz J; Wehr, Michael C

    2018-05-25

    G protein-coupled receptors (GPCRs) are the largest class of cell surface receptors and are implicated in the physiological regulation of many biological processes. The high diversity of GPCRs and their physiological functions make them primary targets for therapeutic drugs. For the generation of novel compounds, however, selectivity towards a given target is a critical issue in drug development as structural similarities between members of GPCR subfamilies exist. Therefore, the activities of multiple GPCRs that are both closely and distantly related to assess compound selectivity need to be tested simultaneously. Here, we present a cell-based multiplexed GPCR activity assay, termed GPCRprofiler, which uses a β-arrestin recruitment strategy and combines split TEV protein-protein interaction and EXT-based barcode technologies. This approach enables simultaneous measurements of receptor activities of multiple GPCR-ligand combinations by applying massively parallelized reporter assays. In proof-of-principle experiments covering 19 different GPCRs, both the specificity of endogenous agonists and the polypharmacological effects of two known antipsychotics on GPCR activities were demonstrated. Technically, normalization of barcode reporters across individual assays allows quantitative pharmacological assays in a parallelized manner. In summary, the GPCRprofiler technique constitutes a flexible and scalable approach, which enables simultaneous profiling of compound actions on multiple receptor activities in living cells.

  2. The root hair assay facilitates the use of genetic and pharmacological tools in order to dissect multiple signalling pathways that lead to programmed cell death.

    Directory of Open Access Journals (Sweden)

    Joanna Kacprzyk

    Full Text Available The activation of programmed cell death (PCD is often a result of complex signalling pathways whose relationship and intersection are not well understood. We recently described a PCD root hair assay and proposed that it could be used to rapidly screen genetic or pharmacological modulators of PCD. To further assess the applicability of the root hair assay for studying multiple signalling pathways leading to PCD activation we have investigated the crosstalk between salicylic acid, autophagy and apoptosis-like PCD (AL-PCD in Arabidopsis thaliana. The root hair assay was used to determine rates of AL-PCD induced by a panel of cell death inducing treatments in wild type plants treated with chemical modulators of salicylic acid synthesis or autophagy, and in genetic lines defective in autophagy or salicylic acid signalling. The assay demonstrated that PCD induced by exogenous salicylic acid or fumonisin B1 displayed a requirement for salicylic acid signalling and was partially dependent on the salicylic acid signal transducer NPR1. Autophagy deficiency resulted in an increase in the rates of AL-PCD induced by salicylic acid and fumonisin B1, but not by gibberellic acid or abiotic stress. The phenylalanine ammonia lyase-dependent salicylic acid synthesis pathway contributed only to death induced by salicylic acid and fumonisin B1. 3-Methyladenine, which is commonly used as an inhibitor of autophagy, appeared to influence PCD induction in all treatments suggesting a possible secondary, non-autophagic, effect on a core component of the plant PCD pathway. The results suggest that salicylic acid signalling is negatively regulated by autophagy during salicylic acid and mycotoxin-induced AL-PCD. However, this crosstalk does not appear to be directly involved in PCD induced by gibberellic acid or abiotic stress. This study demonstrates that the root hair assay is an effective tool for relatively rapid investigation of complex signalling pathways leading to

  3. Cell Culture Assay for Human Noroviruses [response

    Energy Technology Data Exchange (ETDEWEB)

    Straub, Tim M.; Honer Zu Bentrup, Kerstin; Orosz Coghlan, Patricia; Dohnalkova, Alice; Mayer, Brooke K.; Bartholomew, Rachel A.; Valdez, Catherine O.; Bruckner-Lea, Cindy J.; Gerba, Charles P.; Abbaszadegan, Morteza A.; Nickerson, Cheryl A.

    2007-07-01

    We appreciate the comments provided by Leung et al., in response to our recently published article “In Vitro Cell Culture Infectivity Assay for Human Noroviruses” by Straub et al. (1). The specific aim of our project was to develop an in vitro cell culture infectivity assay for human noroviruses (hNoV) to enhance risk assessments when they are detected in water supplies. Reverse transcription (RT) qualitative or quantitative PCR are the primary assays for waterborne NoV monitoring. However, these assays cannot distinguish between infectious vs. non-infectious virions. When hNoV is detected in water supplies, information provided by our infectivity assay will significantly improve risk assessment models and protect human health, regardless of whether we are propagating NoV. Indeed, in vitro cell culture infectivity assays for the waterborne pathogen Cryptosporidium parvum that supplement approved fluorescent microscopy assays, do not result in amplification of the environmentally resistant hard-walled oocysts (2). However, identification of life cycle stages in cell culture provides evidence of infectious oocysts in a water supply. Nonetheless, Leung et al.’s assertion regarding the suitability of our method for the in vitro propagation of high titers of NoV is valid for the medical research community. In this case, well-characterized challenge pools of virus would be useful for developing and testing diagnostics, therapeutics, and vaccines. As further validation of our published findings, we have now optimized RT quantitative PCR to assess the level of viral production in cell culture, where we are indeed finding significant increases in viral titer. The magnitude and time course of these increases is dependent on both virus strain and multiplicity of infection. We are currently preparing a manuscript that will discuss these findings in greater detail, and the implications this may have for creating viral challenge pools

  4. Fluorometric assay for phenotypic differentiation of drug-resistant HIV mutants

    Science.gov (United States)

    Zhu, Qinchang; Yu, Zhiqiang; Kabashima, Tsutomu; Yin, Sheng; Dragusha, Shpend; El-Mahdy, Ahmed F. M.; Ejupi, Valon; Shibata, Takayuki; Kai, Masaaki

    2015-01-01

    Convenient drug-resistance testing of viral mutants is indispensable to effective treatment of viral infection. We developed a novel fluorometric assay for phenotypic differentiation of drug-resistant mutants of human immunodeficiency virus-I protease (HIV-PR) which uses enzymatic and peptide-specific fluorescence (FL) reactions and high-performance liquid chromatography (HPLC) of three HIV-PR substrates. This assay protocol enables use of non-purified enzyme sources and multiple substrates for the enzymatic reaction. In this study, susceptibility of HIV mutations to drugs was evaluated by selective formation of three FL products after the enzymatic HIV-PR reaction. This proof-of-concept study indicates that the present HPLC-FL method could be an alternative to current phenotypic assays for the evaluation of HIV drug resistance. PMID:25988960

  5. Variability in large-scale wind power generation: Variability in large-scale wind power generation

    Energy Technology Data Exchange (ETDEWEB)

    Kiviluoma, Juha [VTT Technical Research Centre of Finland, Espoo Finland; Holttinen, Hannele [VTT Technical Research Centre of Finland, Espoo Finland; Weir, David [Energy Department, Norwegian Water Resources and Energy Directorate, Oslo Norway; Scharff, Richard [KTH Royal Institute of Technology, Electric Power Systems, Stockholm Sweden; Söder, Lennart [Royal Institute of Technology, Electric Power Systems, Stockholm Sweden; Menemenlis, Nickie [Institut de recherche Hydro-Québec, Montreal Canada; Cutululis, Nicolaos A. [DTU, Wind Energy, Roskilde Denmark; Danti Lopez, Irene [Electricity Research Centre, University College Dublin, Dublin Ireland; Lannoye, Eamonn [Electric Power Research Institute, Palo Alto California USA; Estanqueiro, Ana [LNEG, Laboratorio Nacional de Energia e Geologia, UESEO, Lisbon Spain; Gomez-Lazaro, Emilio [Renewable Energy Research Institute and DIEEAC/EDII-AB, Castilla-La Mancha University, Albacete Spain; Zhang, Qin [State Grid Corporation of China, Beijing China; Bai, Jianhua [State Grid Energy Research Institute Beijing, Beijing China; Wan, Yih-Huei [National Renewable Energy Laboratory, Transmission and Grid Integration Group, Golden Colorado USA; Milligan, Michael [National Renewable Energy Laboratory, Transmission and Grid Integration Group, Golden Colorado USA

    2015-10-25

    The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net load events. The comparison shows regions with low variability (Sweden, Spain and Germany), medium variability (Portugal, Ireland, Finland and Denmark) and regions with higher variability (Quebec, Bonneville Power Administration and Electric Reliability Council of Texas in North America; Gansu, Jilin and Liaoning in China; and Norway and offshore wind power in Denmark). For regions with low variability, the maximum 1 h wind ramps are below 10% of nominal capacity, and for regions with high variability, they may be close to 30%. Wind power variability is mainly explained by the extent of geographical spread, but also higher capacity factor causes higher variability. It was also shown how wind power ramps are autocorrelated and dependent on the operating output level. When wind power was concentrated in smaller area, there were outliers with high changes in wind output, which were not present in large areas with well-dispersed wind power.

  6. Evaluation of the neutron self-interrogation approach for assay of plutonium in high materials

    International Nuclear Information System (INIS)

    Russo, P.A.; Menlove, H.O.; Fife, K.W.; West, M.H.

    1987-01-01

    The pyrochemical scrap recovery processes, designed to extract impurities from plutonium metal and compounds, generate a variety of plutonium-laden residues consisting of high (α,n) matrices of varying chemical composition, and often containing grams to tens of grams of americium. For such materials, multiplication corrections based on real neutron coincidence count rate, R, and total neutron count rate, T, measurements cannot be applied because of the large, unknown, and variable (α,n) component in the total neutron emission rate. A study of the prototype self-interrogation assay method is in progress at the Los Alamos plutonium facility. In the self-interrogation approach, the assay signature R(IF)/T is a function of effective fissile plutonium content, where R(IF) is the induced fission component of the measured reals rate, and T is the measured, (α,n)-dominated totals rate. The present study includes a calibration effort using standards consisting of mixtures of PuO 2 and PuF 4 in a salt-strip matrix. The neutron measurements of the standards and the process materials have been performed at the Los Alamos Plutonium Facility. The precision and accuracy of the self-interrogation method applied to pyrochemical residues is examined in this study

  7. Implications of climate variability for the detection of multiple equilibria and for rapid transitions in the atmosphere-vegetation system

    Energy Technology Data Exchange (ETDEWEB)

    Bathiany, S. [Max Planck Institute for Meteorology, Hamburg (Germany); Claussen, M. [Max Planck Institute for Meteorology, Hamburg (Germany); Universitaet Hamburg, Meteorologisches Institut, Hamburg (Germany); Fraedrich, K. [Universitaet Hamburg, Meteorologisches Institut, Hamburg (Germany)

    2012-05-15

    Paleoclimatic records indicate a decline of vegetation cover in the Western Sahara at the end of the African Humid Period (about 5,500 years before present). Modelling studies have shown that this phenomenon may be interpreted as a critical transition that results from a bifurcation in the atmosphere-vegetation system. However, the stability properties of this system are closely linked to climate variability and depend on the climate model and the methods of analysis. By coupling the Planet Simulator (PlaSim), an atmosphere model of intermediate complexity, with the simple dynamic vegetation model VECODE, we assess previous methods for the detection of multiple equilibria, and demonstrate their limitations. In particular, a stability diagram can yield misleading results because of spatial interactions, and the system's steady state and its dependency on initial conditions are affected by atmospheric variability and nonlinearities. In addition, we analyse the implications of climate variability for the abruptness of a vegetation decline. We find that a vegetation collapse can happen at different locations at different times. These collapses are possible despite large and uncorrelated climate variability. Because of the nonlinear relation between vegetation dynamics and precipitation the green state is initially stabilised by the high variability. When precipitation falls below a critical threshold, the desert state is stabilised as variability is then also decreased. (orig.)

  8. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. CRITICAL RADAR: TOOL AND METHODOLOGY FOR EVALUATING CURRENT PROJECTS USING MULTIPLE VARIABLES

    Directory of Open Access Journals (Sweden)

    André M. Ferrari

    2017-06-01

    Full Text Available Many resources are invested in measurement processes of projects indicators without, however, give a clear view of which projects deserves the right attention at the right time. This paper proposes the use of statistics, through the analysis of multiple variables and their interrelationships, to give better basis to a critical assessment methodology of current projects used in a multinational mining company. The contribution of the research is to report the methodology called Critical Radar which is based on a graphical tool with simple operationalization that can support the decision making in complex environments, and has great flexibility across the different market scenarios and possible changes in companies guidelines. The tool has great potential to help evaluate current projects due to their characteristics of flexible use in different business areas; high degree of freedom for improvement; use of known market tool in its development; ease of viewing the results through charts and notes and user freedom to use any existing indicators in the company if complied with some statistical data quality characteristics.

  10. MULTIPLE-LOCUS VARIABLE-NUMBER TANDEM REPEAT ANALYSIS OF BRUCELLA ISOLATES FROM THAILAND.

    Science.gov (United States)

    Kumkrong, Khurawan; Chankate, Phanita; Tonyoung, Wittawat; Intarapuk, Apiradee; Kerdsin, Anusak; Kalambaheti, Thareerat

    2017-01-01

    Brucellosis-induced abortion can result in significant economic loss to farm animals. Brucellosis can be transmitted to humans during slaughter of infected animals or via consumption of contaminated food products. Strain identification of Brucella isolates can reveal the route of transmission. Brucella strains were isolated from vaginal swabs of farm animal, cow milk and from human blood cultures. Multiplex PCR was used to identify Brucella species, and owing to high DNA homology among Brucella isolates, multiple-locus variable-number tandem repeat analysis (MLVA) based on the number of tandem repeats at 16 different genomic loci was used for strain identification. Multiplex PCR categorized the isolates into B. abortus (n = 7), B. melitensis (n = 37), B. suis (n = 3), and 5 of unknown Brucella spp. MLVA-16 clustering analysis differentiated the strains into various genotypes, with Brucella isolates from the same geographic region being closely related, and revealed that the Thai isolates were phylogenetically distinct from those in other countries, including within the Southeast Asian region. Thus, MLVA-16 typing has utility in epidemiological studies.

  11. Optimizing Placement of Weather Stations: Exploring Objective Functions of Meaningful Combinations of Multiple Weather Variables

    Science.gov (United States)

    Snyder, A.; Dietterich, T.; Selker, J. S.

    2017-12-01

    Many regions of the world lack ground-based weather data due to inadequate or unreliable weather station networks. For example, most countries in Sub-Saharan Africa have unreliable, sparse networks of weather stations. The absence of these data can have consequences on weather forecasting, prediction of severe weather events, agricultural planning, and climate change monitoring. The Trans-African Hydro-Meteorological Observatory (TAHMO.org) project seeks to address these problems by deploying and operating a large network of weather stations throughout Sub-Saharan Africa. To design the TAHMO network, we must determine where to place weather stations within each country. We should consider how we can create accurate spatio-temporal maps of weather data and how to balance the desired accuracy of each weather variable of interest (precipitation, temperature, relative humidity, etc.). We can express this problem as a joint optimization of multiple weather variables, given a fixed number of weather stations. We use reanalysis data as the best representation of the "true" weather patterns that occur in the region of interest. For each possible combination of sites, we interpolate the reanalysis data between selected locations and calculate the mean average error between the reanalysis ("true") data and the interpolated data. In order to formulate our multi-variate optimization problem, we explore different methods of weighting each weather variable in our objective function. These methods include systematic variation of weights to determine which weather variables have the strongest influence on the network design, as well as combinations targeted for specific purposes. For example, we can use computed evapotranspiration as a metric that combines many weather variables in a way that is meaningful for agricultural and hydrological applications. We compare the errors of the weather station networks produced by each optimization problem formulation. We also compare these

  12. Multiple dual mode counter-current chromatography with variable duration of alternating phase elution steps.

    Science.gov (United States)

    Kostanyan, Artak E; Erastov, Andrey A; Shishilov, Oleg N

    2014-06-20

    The multiple dual mode (MDM) counter-current chromatography separation processes consist of a succession of two isocratic counter-current steps and are characterized by the shuttle (forward and back) transport of the sample in chromatographic columns. In this paper, the improved MDM method based on variable duration of alternating phase elution steps has been developed and validated. The MDM separation processes with variable duration of phase elution steps are analyzed. Basing on the cell model, analytical solutions are developed for impulse and non-impulse sample loading at the beginning of the column. Using the analytical solutions, a calculation program is presented to facilitate the simulation of MDM with variable duration of phase elution steps, which can be used to select optimal process conditions for the separation of a given feed mixture. Two options of the MDM separation are analyzed: 1 - with one-step solute elution: the separation is conducted so, that the sample is transferred forward and back with upper and lower phases inside the column until the desired separation of the components is reached, and then each individual component elutes entirely within one step; 2 - with multi-step solute elution, when the fractions of individual components are collected in over several steps. It is demonstrated that proper selection of the duration of individual cycles (phase flow times) can greatly increase the separation efficiency of CCC columns. Experiments were carried out using model mixtures of compounds from the GUESSmix with solvent systems hexane/ethyl acetate/methanol/water. The experimental results are compared to the predictions of the theory. A good agreement between theory and experiment has been demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Preliminary report of the comparison of multiple non-destructive assay techniques on LANL Plutonium Facility waste drums

    International Nuclear Information System (INIS)

    Bonner, C.; Schanfein, M.; Estep, R.

    1999-01-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content. The DOE Complex faces the daunting task of measuring nuclear material with both a wide range of masses and matrices. Similarly daunting can be the selection of a non-destructive assay (NDA) technique(s) to efficiently perform the quantitative assay over the entire waste population. In fulfilling its role of a DOE Defense Programs nuclear User Facility/Technology Development Center, the Los Alamos National Laboratory Plutonium Facility recently tested three commercially built and owned, mobile nondestructive assay (NDA) systems with special nuclear materials (SNM). Two independent commercial companies financed the testing of their three mobile NDA systems at the site. Contained within a single trailer is Canberra Industries segmented gamma scanner/waste assay system (SGS/WAS) and neutron waste drum assay system (WDAS). The third system is a BNFL Instruments Inc. (formerly known as Pajarito Scientific Corporation) differential die-away imaging passive/active neutron (IPAN) counter. In an effort to increase the value of this comparison, additional NDA techniques at LANL were also used to measure these same drums. These are comprised of three tomographic gamma scanners (one mobile unit and two stationary) and one developmental differential die-away system. Although not certified standards, the authors hope that such a comparison will provide valuable data for those considering these different NDA techniques to measure their waste as well as the developers of the techniques

  14. Multiple constant multiplication optimizations for field programmable gate arrays

    CERN Document Server

    Kumm, Martin

    2016-01-01

    This work covers field programmable gate array (FPGA)-specific optimizations of circuits computing the multiplication of a variable by several constants, commonly denoted as multiple constant multiplication (MCM). These optimizations focus on low resource usage but high performance. They comprise the use of fast carry-chains in adder-based constant multiplications including ternary (3-input) adders as well as the integration of look-up table-based constant multipliers and embedded multipliers to get the optimal mapping to modern FPGAs. The proposed methods can be used for the efficient implementation of digital filters, discrete transforms and many other circuits in the domain of digital signal processing, communication and image processing. Contents Heuristic and ILP-Based Optimal Solutions for the Pipelined Multiple Constant Multiplication Problem Methods to Integrate Embedded Multipliers, LUT-Based Constant Multipliers and Ternary (3-Input) Adders An Optimized Multiple Constant Multiplication Architecture ...

  15. Evaluation of simultaneous binding of Chromomycin A3 to the multiple sites of DNA by the new restriction enzyme assay.

    Science.gov (United States)

    Murase, Hirotaka; Noguchi, Tomoharu; Sasaki, Shigeki

    2018-06-01

    Chromomycin A3 (CMA3) is an aureolic acid-type antitumor antibiotic. CMA3 forms dimeric complexes with divalent cations, such as Mg 2+ , which strongly binds to the GC rich sequence of DNA to inhibit DNA replication and transcription. In this study, the binding property of CMA3 to the DNA sequence containing multiple GC-rich binding sites was investigated by measuring the protection from hydrolysis by the restriction enzymes, AccII and Fnu4HI, for the center of the CGCG site and the 5'-GC↓GGC site, respectively. In contrast to the standard DNase I footprinting method, the DNA substrates are fully hydrolyzed by the restriction enzymes, therefore, the full protection of DNA at all the cleavable sites indicates that CMA3 simultaneously binds to all the binding sites. The restriction enzyme assay has suggested that CMA3 has a high tendency to bind the successive CGCG sites and the CGG repeat. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A Pan-Lyssavirus Taqman Real-Time RT-PCR Assay for the Detection of Highly Variable Rabies virus and Other Lyssaviruses.

    Science.gov (United States)

    Wadhwa, Ashutosh; Wilkins, Kimberly; Gao, Jinxin; Condori Condori, Rene Edgar; Gigante, Crystal M; Zhao, Hui; Ma, Xiaoyue; Ellison, James A; Greenberg, Lauren; Velasco-Villa, Andres; Orciari, Lillian; Li, Yu

    2017-01-01

    Rabies, resulting from infection by Rabies virus (RABV) and related lyssaviruses, is one of the most deadly zoonotic diseases and is responsible for up to 70,000 estimated human deaths worldwide each year. Rapid and accurate laboratory diagnosis of rabies is essential for timely administration of post-exposure prophylaxis in humans and control of the disease in animals. Currently, only the direct fluorescent antibody (DFA) test is recommended for routine rabies diagnosis. Reverse-transcription polymerase chain reaction (RT-PCR) based diagnostic methods have been widely adapted for the diagnosis of other viral pathogens, but there is currently no widely accepted rapid real-time RT-PCR assay for the detection of all lyssaviruses. In this study, we demonstrate the validation of a newly developed multiplex real-time RT-PCR assay named LN34, which uses a combination of degenerate primers and probes along with probe modifications to achieve superior coverage of the Lyssavirus genus while maintaining sensitivity and specificity. The primers and probes of the LN34 assay target the highly conserved non-coding leader region and part of the nucleoprotein (N) coding sequence of the Lyssavirus genome to maintain assay robustness. The probes were further modified by locked nucleotides to increase their melting temperature to meet the requirements for an optimal real-time RT-PCR assay. The LN34 assay was able to detect all RABV variants and other lyssaviruses in a validation panel that included representative RABV isolates from most regions of the world as well as representatives of 13 additional Lyssavirus species. The LN34 assay was successfully used for both ante-mortem and post-mortem diagnosis of over 200 clinical samples as well as field derived surveillance samples. This assay represents a major improvement over previously published rabies specific RT-PCR and real-time RT-PCR assays because of its ability to universally detect RABV and other lyssaviruses, its high

  17. A Pan-Lyssavirus Taqman Real-Time RT-PCR Assay for the Detection of Highly Variable Rabies virus and Other Lyssaviruses.

    Directory of Open Access Journals (Sweden)

    Ashutosh Wadhwa

    2017-01-01

    Full Text Available Rabies, resulting from infection by Rabies virus (RABV and related lyssaviruses, is one of the most deadly zoonotic diseases and is responsible for up to 70,000 estimated human deaths worldwide each year. Rapid and accurate laboratory diagnosis of rabies is essential for timely administration of post-exposure prophylaxis in humans and control of the disease in animals. Currently, only the direct fluorescent antibody (DFA test is recommended for routine rabies diagnosis. Reverse-transcription polymerase chain reaction (RT-PCR based diagnostic methods have been widely adapted for the diagnosis of other viral pathogens, but there is currently no widely accepted rapid real-time RT-PCR assay for the detection of all lyssaviruses. In this study, we demonstrate the validation of a newly developed multiplex real-time RT-PCR assay named LN34, which uses a combination of degenerate primers and probes along with probe modifications to achieve superior coverage of the Lyssavirus genus while maintaining sensitivity and specificity. The primers and probes of the LN34 assay target the highly conserved non-coding leader region and part of the nucleoprotein (N coding sequence of the Lyssavirus genome to maintain assay robustness. The probes were further modified by locked nucleotides to increase their melting temperature to meet the requirements for an optimal real-time RT-PCR assay. The LN34 assay was able to detect all RABV variants and other lyssaviruses in a validation panel that included representative RABV isolates from most regions of the world as well as representatives of 13 additional Lyssavirus species. The LN34 assay was successfully used for both ante-mortem and post-mortem diagnosis of over 200 clinical samples as well as field derived surveillance samples. This assay represents a major improvement over previously published rabies specific RT-PCR and real-time RT-PCR assays because of its ability to universally detect RABV and other lyssaviruses

  18. QuantWorm: a comprehensive software package for Caenorhabditis elegans phenotypic assays.

    Directory of Open Access Journals (Sweden)

    Sang-Kyu Jung

    Full Text Available Phenotypic assays are crucial in genetics; however, traditional methods that rely on human observation are unsuitable for quantitative, large-scale experiments. Furthermore, there is an increasing need for comprehensive analyses of multiple phenotypes to provide multidimensional information. Here we developed an automated, high-throughput computer imaging system for quantifying multiple Caenorhabditis elegans phenotypes. Our imaging system is composed of a microscope equipped with a digital camera and a motorized stage connected to a computer running the QuantWorm software package. Currently, the software package contains one data acquisition module and four image analysis programs: WormLifespan, WormLocomotion, WormLength, and WormEgg. The data acquisition module collects images and videos. The WormLifespan software counts the number of moving worms by using two time-lapse images; the WormLocomotion software computes the velocity of moving worms; the WormLength software measures worm body size; and the WormEgg software counts the number of eggs. To evaluate the performance of our software, we compared the results of our software with manual measurements. We then demonstrated the application of the QuantWorm software in a drug assay and a genetic assay. Overall, the QuantWorm software provided accurate measurements at a high speed. Software source code, executable programs, and sample images are available at www.quantworm.org. Our software package has several advantages over current imaging systems for C. elegans. It is an all-in-one package for quantifying multiple phenotypes. The QuantWorm software is written in Java and its source code is freely available, so it does not require use of commercial software or libraries. It can be run on multiple platforms and easily customized to cope with new methods and requirements.

  19. A multiplex branched DNA assay for parallel quantitative gene expression profiling.

    Science.gov (United States)

    Flagella, Michael; Bui, Son; Zheng, Zhi; Nguyen, Cung Tuong; Zhang, Aiguo; Pastor, Larry; Ma, Yunqing; Yang, Wen; Crawford, Kimberly L; McMaster, Gary K; Witney, Frank; Luo, Yuling

    2006-05-01

    We describe a novel method to quantitatively measure messenger RNA (mRNA) expression of multiple genes directly from crude cell lysates and tissue homogenates without the need for RNA purification or target amplification. The multiplex branched DNA (bDNA) assay adapts the bDNA technology to the Luminex fluorescent bead-based platform through the use of cooperative hybridization, which ensures an exceptionally high degree of assay specificity. Using in vitro transcribed RNA as reference standards, we demonstrated that the assay is highly specific, with cross-reactivity less than 0.2%. We also determined that the assay detection sensitivity is 25,000 RNA transcripts with intra- and interplate coefficients of variance of less than 10% and less than 15%, respectively. Using three 10-gene panels designed to measure proinflammatory and apoptosis responses, we demonstrated sensitive and specific multiplex gene expression profiling directly from cell lysates. The gene expression change data demonstrate a high correlation coefficient (R(2)=0.94) compared with measurements obtained using the single-plex bDNA assay. Thus, the multiplex bDNA assay provides a powerful means to quantify the gene expression profile of a defined set of target genes in large sample populations.

  20. Intra-individual variability in information processing speed reflects white matter microstructure in multiple sclerosis.

    Science.gov (United States)

    Mazerolle, Erin L; Wojtowicz, Magdalena A; Omisade, Antonina; Fisk, John D

    2013-01-01

    Slowed information processing speed is commonly reported in persons with multiple sclerosis (MS), and is typically investigated using clinical neuropsychological tests, which provide sensitive indices of mean-level information processing speed. However, recent studies have demonstrated that within-person variability or intra-individual variability (IIV) in information processing speed may be a more sensitive indicator of neurologic status than mean-level performance on clinical tests. We evaluated the neural basis of increased IIV in mildly affected relapsing-remitting MS patients by characterizing the relation between IIV (controlling for mean-level performance) and white matter integrity using diffusion tensor imaging (DTI). Twenty women with relapsing-remitting MS and 20 matched control participants completed the Computerized Test of Information Processing (CTIP), from which both mean response time and IIV were calculated. Other clinical measures of information processing speed were also collected. Relations between IIV on the CTIP and DTI metrics of white matter microstructure were evaluated using tract-based spatial statistics. We observed slower and more variable responses on the CTIP in MS patients relative to controls. Significant relations between white matter microstructure and IIV were observed for MS patients. Increased IIV was associated with reduced integrity in more white matter tracts than was slowed information processing speed as measured by either mean CTIP response time or other neuropsychological test scores. Thus, despite the common use of mean-level performance as an index of cognitive dysfunction in MS, IIV may be more sensitive to the overall burden of white matter disease at the microstructural level. Furthermore, our study highlights the potential value of considering within-person fluctuations, in addition to mean-level performance, for uncovering brain-behavior relationships in neurologic disorders with widespread white matter pathology.

  1. Storage Conditions of Conjugated Reagents Can Impact Results of Immunogenicity Assays

    Directory of Open Access Journals (Sweden)

    Robert J. Kubiak

    2016-01-01

    Full Text Available Consistent performance of anti-drug antibody (ADA assays through all stages of clinical development is critical for the assessment of immunogenicity and interpretation of PK, PD, safety, and efficacy. The electrochemiluminescent assays commonly employed for ADA measurement use drug conjugated with ruthenium and biotin to bind ADA in samples. Here we report an association between high nonspecific ADA responses in certain drug-naïve individuals and the storage buffer of the conjugated reagents used in a monoclonal antibody ADA assay. Ruthenylated reagents stored in phosphate-buffered saline (PBS buffer had increased levels of aggregate and produced variable and high baseline responses in some subjects. Reagents stored in a histidine-sucrose buffer (HSB had lower aggregate levels and produced low sample responses. In contrast to PBS, conjugated reagents formulated in HSB remained low in aggregate content and in sample response variability after 5 freeze/thaw cycles. A reagent monitoring control (RMC serum was prepared for the real-time evaluation of conjugated reagent quality. Using appropriate buffers for storage of conjugated reagents together with RMCs capable of monitoring of reagent aggregation status can help ensure consistent, long-term performance of ADA methods.

  2. Development and application of a quantitative multiplexed small GTPase activity assay using targeted proteomics.

    Science.gov (United States)

    Zhang, Cheng-Cheng; Li, Ru; Jiang, Honghui; Lin, Shujun; Rogalski, Jason C; Liu, Kate; Kast, Juergen

    2015-02-06

    Small GTPases are a family of key signaling molecules that are ubiquitously expressed in various types of cells. Their activity is often analyzed by western blot, which is limited by its multiplexing capability, the quality of isoform-specific antibodies, and the accuracy of quantification. To overcome these issues, a quantitative multiplexed small GTPase activity assay has been developed. Using four different binding domains, this assay allows the binding of up to 12 active small GTPase isoforms simultaneously in a single experiment. To accurately quantify the closely related small GTPase isoforms, a targeted proteomic approach, i.e., selected/multiple reaction monitoring, was developed, and its functionality and reproducibility were validated. This assay was successfully applied to human platelets and revealed time-resolved coactivation of multiple small GTPase isoforms in response to agonists and differential activation of these isoforms in response to inhibitor treatment. This widely applicable approach can be used for signaling pathway studies and inhibitor screening in many cellular systems.

  3. Relapse May Serve as a Mediator Variable in Longitudinal Outcomes in Multiple Sclerosis.

    Science.gov (United States)

    Stone, Lael Anne; Cutter, Gary Raymond; Fisher, Elizabeth; Richert, Nancy; McCartin, Jennifer; Ohayon, Joan; Bash, Craig; McFarland, Henry

    2016-05-01

    Contrast-enhancing lesions (CEL) on magnetic resonance imaging (MRI) are believed to represent inflammatory disease activity in multiple sclerosis (MS), but their relationship to subsequent long-term disability and progression is unclear, particularly at longer time periods such as 8-10 years. Between 1989 and 1994, 111 MS patients were seen at the National Institutes of Health for clinical evaluations and 3 monthly contrast-enhanced MRI scans. Of these, 94 patients were re-evaluated a mean of 8 years later (range 6.1-10.5 years) with a single MRI scan and clinical evaluation. CEL number and volume were determined at baseline and follow-up. The number of relapses was ascertained over the follow-up period and annualized relapse rates were calculated. Other MRI parameters, such as T2 hyperintensity volume, T1 volume, and brain parenchymal fraction, were also calculated. While there was no direct correlation between CEL number or volume at baseline and disability status at follow-up, CEL measures at baseline did correlate with number of relapses observed in the subsequent years, and the number of relapses in turn correlated with subsequent disability as well as transition to progressive MS. While number and volume of CEL at baseline do not directly correlate with disability in the longer term in MS, our data suggest that 1 route to disability involves relapses as a mediator variable in the causal sequence of MS progression from CEL to disability. Further studies using relapse as a mediator variable in a larger data set may be warranted. Copyright © 2015 by the American Society of Neuroimaging.

  4. Comparison of non-magnetic and magnetic beads in bead-based assays

    NARCIS (Netherlands)

    Hansenová Maňásková, S.; van Belkum, A.; Endtz, H.P.; Bikker, F.J.; Veerman, E.C.I.; van Wamel, W.J.B.

    2016-01-01

    Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens

  5. 77 FR 68784 - Prospective Grant of Exclusive License: Multiple-Valent Opsonophagocytic Assay Selection Panel...

    Science.gov (United States)

    2012-11-16

    ... Licensing and Marketing Specialist, Technology Transfer Office, Centers for Disease Control and Prevention... Technology Transfer Office, Centers for Disease Control and Prevention (CDC), Department of Health and Human... Opsonophagocytic Assay Selection Panel Arrays and Uses Therefor'', issued 1/5/2010. CDC Technology ID No. I-035-04...

  6. Sum of ratios of products forα-μ random variables in wireless multihop relaying and multiple scattering

    KAUST Repository

    Wang, Kezhi; Wang, Tian; Chen, Yunfei; Alouini, Mohamed-Slim

    2014-01-01

    The sum of ratios of products of independent 2642 2642α-μ random variables (RVs) is approximated by using the Generalized Gamma ratio approximation (GGRA) with Gamma ratio approximation (GRA) as a special case. The proposed approximation is used to calculate the outage probability of the equal gain combining (EGC) or maximum ratio combining (MRC) receivers for wireless multihop relaying or multiple scattering systems considering interferences. Numerical results show that the newly derived approximation works very well verified by the simulation, while GRA has a slightly worse performance than GGRA when outage probability is below 0.1 but with a more simplified form.

  7. Sum of ratios of products forα-μ random variables in wireless multihop relaying and multiple scattering

    KAUST Repository

    Wang, Kezhi

    2014-09-01

    The sum of ratios of products of independent 2642 2642α-μ random variables (RVs) is approximated by using the Generalized Gamma ratio approximation (GGRA) with Gamma ratio approximation (GRA) as a special case. The proposed approximation is used to calculate the outage probability of the equal gain combining (EGC) or maximum ratio combining (MRC) receivers for wireless multihop relaying or multiple scattering systems considering interferences. Numerical results show that the newly derived approximation works very well verified by the simulation, while GRA has a slightly worse performance than GGRA when outage probability is below 0.1 but with a more simplified form.

  8. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    Science.gov (United States)

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  9. The impact of vehicle on the relative potency of skin-sensitizing chemicals in the local lymph node assay.

    Science.gov (United States)

    Jowsey, Ian R; Clapp, Catherine J; Safford, Bob; Gibbons, Ben T; Basketter, David A

    2008-01-01

    The identification and characterization of chemicals that possess skin-sensitizing potential are typically performed using predictive tests. However, human exposure to skin-sensitizing chemicals often occurs via a matrix (vehicle) that differs from that used in these tests. It is thus important to account for the potential impact of vehicle differences when undertaking quantitative risk assessment for skin sensitization. This is achieved through the application of a specific sensitization assessment factor (SAF), scaled between 1 and 10, when identifying an acceptable exposure level. The objective of the analysis described herein is to determine the impact of vehicle differences on local lymph node assay (LLNA) EC3 values (concentrations of test chemical required to provoke a 3-fold increase in lymph node cell proliferation). Initially, the inherent variability of the LLNA was investigated by examining the reproducibility of EC3 values for 14 chemicals that have been tested more than once in the same vehicle (4:1 acetone:olive oil, AOO). This analysis reveals that the variability in EC3 value for these chemicals following multiple assessments is LLNA using at least 2 of 15 different vehicles. These data demonstrate that often the variability in EC3 values observed for a given chemical in different vehicles is no greater than the 5-fold inherent variability observed when assessing a chemical in the same vehicle on multiple occasions. However, there are examples where EC3 values for a chemical differ by a factor of more than 10 between different vehicles. These observations were often associated with an apparent underestimation of potency (higher EC3 values) with predominantly aqueous vehicles or propylene glycol. These data underscore the need to consider vehicle effects in the context of skin-sensitization risk assessments.

  10. Serum total antioxidant capacity in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Almira Hadžović-Džuvo

    2011-02-01

    Full Text Available Multiple sclerosis (MS is a chronic inflammatory disease of the central nervous system (CNS. It is characterized by loss of myelin, the fatty tissue that surrounds and protects nerve fibres allowing them to conduct electrical impulses. Recent data indicate that oxidative stress (OS plays a major role in the pathogenesis of multiple sclerosis (MS. The aim of this study was to estimate level of serum total antioxidative capacity in patients with multiple sclerosis. Our cross-sectional study included 33 patients with MS and 24 age and sex matched control subjects. All our patients had a Poser criteria for definite diagnostic categories of multiple sclerosis. Serum total antioxidant capacity (TAC was measured by quantitative colorimetric determination, using Total antioxidant Capacity-QuantiCromAntioxidant Assay Kit (BioAssay systems, USA; DTAC-100. Mean serum TAC in multiple sclerosis group of patients was 119.2 mM Trolox equivalents and was significantly lower (p<0.001 compared to the control group of subjects (167.1 mM Trolox equivalents. Our results showed that oxidative stress plays an important role in pathogenesis of multiple sclerosis. This finding, also, suggests the importance of antioxidants in diet and therapy of MS patients.

  11. A Qualitative and Quantitative Assay to Study DNA/Drug Interaction ...

    African Journals Online (AJOL)

    Purpose: To explore the use of restriction inhibition assay (RIA) to study the binding specificity of some anticancer drugs. Methods: A 448 bp DNA fragment derived from pBCKS+ plasmid (harboring the polylinker region with multiple restriction endonuclease sites) was used as a template for sequence selective inhibition of ...

  12. Numerical Investigation of Multiple-, Interacting-Scale Variable-Density Ground Water Flow Systems

    Science.gov (United States)

    Cosler, D.; Ibaraki, M.

    2004-12-01

    The goal of our study is to elucidate the nonlinear processes that are important for multiple-, interacting-scale flow and solute transport in subsurface environments. In particular, we are focusing on the influence of small-scale instability development on variable-density ground water flow behavior in large-scale systems. Convective mixing caused by these instabilities may mix the fluids to a greater extent than would be the case with classical, Fickian dispersion. Most current numerical schemes for interpreting field-scale variable-density flow systems do not explicitly account for the complexities caused by small-scale instabilities and treat such processes as "lumped" Fickian dispersive mixing. Such approaches may greatly underestimate the mixing behavior and misrepresent the overall large-scale flow field dynamics. The specific objectives of our study are: (i) to develop an adaptive (spatial and temporal scales) three-dimensional numerical model that is fully capable of simulating field-scale variable-density flow systems with fine resolution (~1 cm); and (ii) to evaluate the importance of scale-dependent process interactions by performing a series of simulations on different problem scales ranging from laboratory experiments to field settings, including an aquifer storage and freshwater recovery (ASR) system similar to those planned for the Florida Everglades and in-situ contaminant remediation systems. We are examining (1) methods to create instabilities in field-scale systems, (2) porous media heterogeneity effects, and (3) the relation between heterogeneity characteristics (e.g., permeability variance and correlation length scales) and the mixing scales that develop for varying degrees of unstable stratification. Applications of our work include the design of new water supply and conservation measures (e.g., ASR systems), assessment of saltwater intrusion problems in coastal aquifers, and the design of in-situ remediation systems for aquifer restoration

  13. FIRE: an SPSS program for variable selection in multiple linear regression analysis via the relative importance of predictors.

    Science.gov (United States)

    Lorenzo-Seva, Urbano; Ferrando, Pere J

    2011-03-01

    We provide an SPSS program that implements currently recommended techniques and recent developments for selecting variables in multiple linear regression analysis via the relative importance of predictors. The approach consists of: (1) optimally splitting the data for cross-validation, (2) selecting the final set of predictors to be retained in the equation regression, and (3) assessing the behavior of the chosen model using standard indices and procedures. The SPSS syntax, a short manual, and data files related to this article are available as supplemental materials from brm.psychonomic-journals.org/content/supplemental.

  14. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    Science.gov (United States)

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in

  15. Weight analyses and nitrogen balance assay in rats fed extruded ...

    African Journals Online (AJOL)

    Weight analyses and nitrogen balance assay in adult rats in raw and extruded African breadfruit (Treculia africana) based diets were carried out using response surface methodology in a central composite design. Process variables were feed composition (40 - 100 % African breadfruit, 0 - 5 % corn and 0 - 55 % soybean, ...

  16. Evaluation of the TEG® platelet mappingTM assay in blood donors

    DEFF Research Database (Denmark)

    Bochsen, Louise; Wiinberg, Bo; Kjelgaard-Hansen, Mads Jens

    2007-01-01

    for quantification of platelet function, including the contribution of the adenosine diphosphate (ADP) and thromboxane A2 (TxA2) receptors to clot formation. Methods In 43 healthy blood donors, the analytical (CVa) and inter-individual variability (CVg) of the TEG® Platelet MappingTM assay were determined together......Background Monitoring of antiplatelet therapy in patients at cardiovascular risk is difficult because existing platelet function tests are too sophisticated for clinical routine. The whole blood TEG® Platelet MappingTM assay measures clot strength as maximal amplitude (MA) and enables...

  17. Sensitive microplate assay for the detection of proteolytic enzymes using radiolabeled gelatin

    International Nuclear Information System (INIS)

    Robertson, B.D.; Kwan-Lim, G.E.; Maizels, R.M.

    1988-01-01

    A sensitive, microplate assay is described for the detection of a wide range of proteolytic enzymes, using radio-iodine-labeled gelatin as substrate. The technique uses the Bolton-Hunter reagent to label the substrate, which is then coated onto the wells of polyvinyl chloride microtiter plates. By measuring the radioactivity released the assay is able to detect elastase, trypsin, and collagenase in concentrations of 1 ng/ml or less, while the microtiter format permits multiple sample handling and minimizes sample volumes required for analysis

  18. Spatio-temporal Variability in Surface Ocean pCO2 Inferred from Observations

    OpenAIRE

    Jones, Steve

    2012-01-01

    The variability of surface ocean pCO2 is examined on multiple spatial and temporal scales. Temporal autocorrelation analysis is used to examine pCO2 variability over multiple years. Spatial autocorrelation analysis describes pCO2 variability over multiple spatial scales. Spatial autocorrelation lengths range between

  19. Statistics of α-μ Random Variables and Their Applications inWireless Multihop Relaying and Multiple Scattering Channels

    KAUST Repository

    Wang, Kezhi

    2015-06-01

    Exact results for the probability density function (PDF) and cumulative distribution function (CDF) of the sum of ratios of products (SRP) and the sum of products (SP) of independent α-μ random variables (RVs) are derived. They are in the form of 1-D integral based on the existing works on the products and ratios of α-μ RVs. In the derivation, generalized Gamma (GG) ratio approximation (GGRA) is proposed to approximate SRP. Gamma ratio approximation (GRA) is proposed to approximate SRP and the ratio of sums of products (RSP). GG approximation (GGA) and Gamma approximation (GA) are used to approximate SP. The proposed results of the SRP can be used to calculate the outage probability (OP) for wireless multihop relaying systems or multiple scattering channels with interference. The proposed results of the SP can be used to calculate the OP for these systems without interference. In addition, the proposed approximate result of the RSP can be used to calculate the OP of the signal-To-interference ratio (SIR) in a multiple scattering system with interference. © 1967-2012 IEEE.

  20. Statistics of α-μ Random Variables and Their Applications inWireless Multihop Relaying and Multiple Scattering Channels

    KAUST Repository

    Wang, Kezhi; Wang, Tian; Chen, Yunfei; Alouini, Mohamed-Slim

    2015-01-01

    Exact results for the probability density function (PDF) and cumulative distribution function (CDF) of the sum of ratios of products (SRP) and the sum of products (SP) of independent α-μ random variables (RVs) are derived. They are in the form of 1-D integral based on the existing works on the products and ratios of α-μ RVs. In the derivation, generalized Gamma (GG) ratio approximation (GGRA) is proposed to approximate SRP. Gamma ratio approximation (GRA) is proposed to approximate SRP and the ratio of sums of products (RSP). GG approximation (GGA) and Gamma approximation (GA) are used to approximate SP. The proposed results of the SRP can be used to calculate the outage probability (OP) for wireless multihop relaying systems or multiple scattering channels with interference. The proposed results of the SP can be used to calculate the OP for these systems without interference. In addition, the proposed approximate result of the RSP can be used to calculate the OP of the signal-To-interference ratio (SIR) in a multiple scattering system with interference. © 1967-2012 IEEE.

  1. Development of a multiple immunoaffinity column for simultaneous determination of multiple mycotoxins in feeds using UPLC-MS/MS.

    Science.gov (United States)

    Hu, Xiaofeng; Hu, Rui; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Wang, Min

    2016-09-01

    A sensitive and specific immunoaffinity column to clean up and isolate multiple mycotoxins was developed along with a rapid one-step sample preparation procedure for ultra-performance liquid chromatography-tandem mass spectrometry analysis. Monoclonal antibodies against aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2, zearalenone, ochratoxin A, sterigmatocystin, and T-2 toxin were coupled to microbeads for mycotoxin purification. We optimized a homogenization and extraction procedure as well as column loading and elution conditions to maximize recoveries from complex feed matrices. This method allowed rapid, simple, and simultaneous determination of mycotoxins in feeds with a single chromatographic run. Detection limits for these toxins ranged from 0.006 to 0.12 ng mL(-1), and quantitation limits ranged from 0.06 to 0.75 ng mL(-1). Concentration curves were linear from 0.12 to 40 μg kg(-1) with correlation coefficients of R (2) > 0.99. Intra-assay and inter-assay comparisons indicated excellent repeatability and reproducibility of the multiple immunoaffinity columns. As a proof of principle, 80 feed samples were tested and several contained multiple mycotoxins. This method is sensitive, rapid, and durable enough for multiple mycotoxin determinations that fulfill European Union and Chinese testing criteria.

  2. Development and validation of a single-tube multiple-locus variable number tandem repeat analysis for Klebsiella pneumoniae.

    Directory of Open Access Journals (Sweden)

    Antoinette A T P Brink

    Full Text Available Genotyping of Klebsiella pneumoniae is indispensable for management of nosocomial infections, monitoring of emerging strains--including extended-spectrum beta-lactamase (ESBL producers-, and general epidemiology. Such objectives require a high-resolution genotyping method with a fixed scheme that allows (1 long-term retrospective and prospective assessment, (2 objective result readout and (3 library storage for database development and exchangeable results. We have developed a multiple-locus variable number tandem repeat analysis (MLVA using a single-tube fluorescently primed multiplex PCR for 8 Variable Number Tandem Repeats (VNTRs and automated fragment size analysis. The type allocation scheme was optimized using 224 K. pneumoniae clinical isolates, which yielded 101 MLVA types. The method was compared to the gold standard multilocus sequence typing (MLST using a subset of these clinical isolates (n = 95 and found to be highly concordant, with at least as high a resolution but with considerably less hands-on time. Our results position this MLVA scheme as an appropriate, high-throughput and relatively low-cost tool for K. pneumoniae epidemiology.

  3. Correction of the significance level when attempting multiple transformations of an explanatory variable in generalized linear models

    Science.gov (United States)

    2013-01-01

    Background In statistical modeling, finding the most favorable coding for an exploratory quantitative variable involves many tests. This process involves multiple testing problems and requires the correction of the significance level. Methods For each coding, a test on the nullity of the coefficient associated with the new coded variable is computed. The selected coding corresponds to that associated with the largest statistical test (or equivalently the smallest pvalue). In the context of the Generalized Linear Model, Liquet and Commenges (Stat Probability Lett,71:33–38,2005) proposed an asymptotic correction of the significance level. This procedure, based on the score test, has been developed for dichotomous and Box-Cox transformations. In this paper, we suggest the use of resampling methods to estimate the significance level for categorical transformations with more than two levels and, by definition those that involve more than one parameter in the model. The categorical transformation is a more flexible way to explore the unknown shape of the effect between an explanatory and a dependent variable. Results The simulations we ran in this study showed good performances of the proposed methods. These methods were illustrated using the data from a study of the relationship between cholesterol and dementia. Conclusion The algorithms were implemented using R, and the associated CPMCGLM R package is available on the CRAN. PMID:23758852

  4. International network for comparison of HIV neutralization assays: the NeutNet report.

    Science.gov (United States)

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays. Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression. PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent. The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of neutralizing

  5. Preliminary A ampersand PCT multiple detector design

    International Nuclear Information System (INIS)

    Roberson, G.P.; Martz, H.E.; Camp, D.C.; Decman, D.J.; Johansson, E.M.

    1997-01-01

    The next generation, multi-detector active and passive computed tomography (A ampersand PCT) scanner will be optimized for speed and accuracy. At the Lawrence Livermore National Lab (LLNL) we have demonstrated the trade-offs between different A ampersand PCT design parameters that affect the speed and quality of the assay results. These fundamental parameters govern the optimum system design. Although the multi-detector scanner design has priority put on speed to increase waste drum throughput, higher speed should not compromise assay accuracy. One way to increase the speed of the A ampersand PCT technology is to use multiple detectors. This yields a linear speedup by a factor approximately equal to the number of detectors used without a compromise in system accuracy. There are many different design scenarios that can be developed using multiple detectors. Here we describe four different scenarios and discuss the trade-offs between them. Also, some considerations are given in this design description for the implementation of a multiple detector technology in a field- deployable mobile trailer system

  6. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  7. Optimization of Phenotyping Assays for the Model Monocot Setaria viridis.

    Science.gov (United States)

    Acharya, Biswa R; Roy Choudhury, Swarup; Estelle, Aiden B; Vijayakumar, Anitha; Zhu, Chuanmei; Hovis, Laryssa; Pandey, Sona

    2017-01-01

    Setaria viridis (green foxtail) is an important model plant for the study of C4 photosynthesis in panicoid grasses, and is fast emerging as a system of choice for the study of plant development, domestication, abiotic stress responses and evolution. Basic research findings in Setaria are expected to advance research not only in this species and its close relative S. italica (foxtail millet), but also in other panicoid grasses, many of which are important food or bioenergy crops. Here we report on the standardization of multiple growth and development assays for S. viridis under controlled conditions, and in response to several phytohormones and abiotic stresses. We optimized these assays at three different stages of the plant's life: seed germination and post-germination growth using agar plate-based assays, early seedling growth and development using germination pouch-based assays, and adult plant growth and development under environmentally controlled growth chambers and greenhouses. These assays will be useful for the community to perform large scale phenotyping analyses, mutant screens, comparative physiological analysis, and functional characterization of novel genes of Setaria or other related agricultural crops. Precise description of various growth conditions, effective treatment conditions and description of the resultant phenotypes will help expand the use of S. viridis as an effective model system.

  8. Optimization of Phenotyping Assays for the Model Monocot Setaria viridis

    Directory of Open Access Journals (Sweden)

    Biswa R. Acharya

    2017-12-01

    Full Text Available Setaria viridis (green foxtail is an important model plant for the study of C4 photosynthesis in panicoid grasses, and is fast emerging as a system of choice for the study of plant development, domestication, abiotic stress responses and evolution. Basic research findings in Setaria are expected to advance research not only in this species and its close relative S. italica (foxtail millet, but also in other panicoid grasses, many of which are important food or bioenergy crops. Here we report on the standardization of multiple growth and development assays for S. viridis under controlled conditions, and in response to several phytohormones and abiotic stresses. We optimized these assays at three different stages of the plant’s life: seed germination and post-germination growth using agar plate-based assays, early seedling growth and development using germination pouch-based assays, and adult plant growth and development under environmentally controlled growth chambers and greenhouses. These assays will be useful for the community to perform large scale phenotyping analyses, mutant screens, comparative physiological analysis, and functional characterization of novel genes of Setaria or other related agricultural crops. Precise description of various growth conditions, effective treatment conditions and description of the resultant phenotypes will help expand the use of S. viridis as an effective model system.

  9. HIV-1 Genetic Variability in Cuba and Implications for Transmission and Clinical Progression.

    Science.gov (United States)

    Blanco, Madeline; Machado, Liuber Y; Díaz, Héctor; Ruiz, Nancy; Romay, Dania; Silva, Eladio

    2015-10-01

    INTRODUCTION Serological and molecular HIV-1 studies in Cuba have shown very low prevalence of seropositivity, but an increasing genetic diversity attributable to introduction of many HIV-1 variants from different areas, exchange of such variants among HIV-positive people with several coinciding routes of infection and other epidemiologic risk factors in the seropositive population. The high HIV-1 genetic variability observed in Cuba has possible implications for transmission and clinical progression. OBJECTIVE Study genetic variability for the HIV-1 env, gag and pol structural genes in Cuba; determine the prevalence of B and non-B subtypes according to epidemiologic and behavioral variables and determine whether a relationship exists between genetic variability and transmissibility, and between genetic variability and clinical disease progression in people living with HIV/AIDS. METHODS Using two molecular assays (heteroduplex mobility assay and nucleic acid sequencing), structural genes were characterized in 590 people with HIV-1 (480 men and 110 women), accounting for 3.4% of seropositive individuals in Cuba as of December 31, 2013. Nonrandom sampling, proportional to HIV prevalence by province, was conducted. Relationships between molecular results and viral factors, host characteristics, and patients' clinical, epidemiologic and behavioral variables were studied for molecular epidemiology, transmission, and progression analyses. RESULTS Molecular analysis of the three HIV-1 structural genes classified 297 samples as subtype B (50.3%), 269 as non-B subtypes (45.6%) and 24 were not typeable. Subtype B prevailed overall and in men, mainly in those who have sex with men. Non-B subtypes were prevalent in women and heterosexual men, showing multiple circulating variants and recombinant forms. Sexual transmission was the predominant form of infection for all. B and non-B subtypes were encountered throughout Cuba. No association was found between subtypes and

  10. An HTS-compatible 3D colony formation assay to identify tumor-specific chemotherapeutics.

    Science.gov (United States)

    Horman, Shane R; To, Jeremy; Orth, Anthony P

    2013-12-01

    There has been increasing interest in the development of cellular behavior models that take advantage of three-dimensional (3D) cell culture. To enable assessment of differential perturbagen impacts on cell growth in 2D and 3D, we have miniaturized and adapted for high-throughput screening (HTS) the soft agar colony formation assay, employing a laser-scanning cytometer to image and quantify multiple cell types simultaneously. The assay is HTS compatible, providing high-quality, image-based, replicable data for multiple, co-cultured cell types. As proof of concept, we subjected colorectal carcinoma colonies in 3D soft agar to a mini screen of 1528 natural product compounds. Hit compounds from the primary screen were rescreened in an HTS 3D co-culture matrix containing colon stromal cells and cancer cells. By combining tumor cells and normal, nontransformed colon epithelial cells in one primary screening assay, we were able to obtain differential IC50 data, thereby distinguishing tumor-specific compounds from general cytotoxic compounds. Moreover, we were able to identify compounds that antagonized tumor colony formation in 3D only, highlighting the importance of this assay in identifying agents that interfere with 3D tumor structural growth. This screening platform provides a fast, simple, and robust method for identification of tumor-specific agents in a biologically relevant microenvironment.

  11. Multivariate quantile mapping bias correction: an N-dimensional probability density function transform for climate model simulations of multiple variables

    Science.gov (United States)

    Cannon, Alex J.

    2018-01-01

    Most bias correction algorithms used in climatology, for example quantile mapping, are applied to univariate time series. They neglect the dependence between different variables. Those that are multivariate often correct only limited measures of joint dependence, such as Pearson or Spearman rank correlation. Here, an image processing technique designed to transfer colour information from one image to another—the N-dimensional probability density function transform—is adapted for use as a multivariate bias correction algorithm (MBCn) for climate model projections/predictions of multiple climate variables. MBCn is a multivariate generalization of quantile mapping that transfers all aspects of an observed continuous multivariate distribution to the corresponding multivariate distribution of variables from a climate model. When applied to climate model projections, changes in quantiles of each variable between the historical and projection period are also preserved. The MBCn algorithm is demonstrated on three case studies. First, the method is applied to an image processing example with characteristics that mimic a climate projection problem. Second, MBCn is used to correct a suite of 3-hourly surface meteorological variables from the Canadian Centre for Climate Modelling and Analysis Regional Climate Model (CanRCM4) across a North American domain. Components of the Canadian Forest Fire Weather Index (FWI) System, a complicated set of multivariate indices that characterizes the risk of wildfire, are then calculated and verified against observed values. Third, MBCn is used to correct biases in the spatial dependence structure of CanRCM4 precipitation fields. Results are compared against a univariate quantile mapping algorithm, which neglects the dependence between variables, and two multivariate bias correction algorithms, each of which corrects a different form of inter-variable correlation structure. MBCn outperforms these alternatives, often by a large margin

  12. Novel method for the high-throughput processing of slides for the comet assay.

    Science.gov (United States)

    Karbaschi, Mahsa; Cooke, Marcus S

    2014-11-26

    Single cell gel electrophoresis (the comet assay), continues to gain popularity as a means of assessing DNA damage. However, the assay's low sample throughput and laborious sample workup procedure are limiting factors to its application. "Scoring", or individually determining DNA damage levels in 50 cells per treatment, is time-consuming, but with the advent of high-throughput scoring, the limitation is now the ability to process significant numbers of comet slides. We have developed a novel method by which multiple slides may be manipulated, and undergo electrophoresis, in batches of 25 rather than individually and, importantly, retains the use of standard microscope comet slides, which are the assay convention. This decreases assay time by 60%, and benefits from an electrophoresis tank with a substantially smaller footprint, and more uniform orientation of gels during electrophoresis. Our high-throughput variant of the comet assay greatly increases the number of samples analysed, decreases assay time, number of individual slide manipulations, reagent requirements and risk of damage to slides. The compact nature of the electrophoresis tank is of particular benefit to laboratories where bench space is at a premium. This novel approach is a significant advance on the current comet assay procedure.

  13. A UK NEQAS ISH multicenter ring study using the Ventana HER2 dual-color ISH assay.

    LENUS (Irish Health Repository)

    Bartlett, J M S

    2011-01-01

    We performed a multicenter assessment of a new HER2 dual-color chromogenic in situ hybridization (CISH) test and herein report on concordance of CISH data with fluorescence in situ hybridization (FISH) data and intraobserver and interlaboratory scoring consistency. HER2 results were evaluated using duplicate cores from 30 breast cancers in 5 laboratories using the Ventana HER2 dual-color ISH assay (Ventana Medical Systems, Cambridgeshire, England) and in 1 central laboratory using a standard FISH assay. Overall 93.3% of cases were successfully analyzed by CISH across the 5 participating laboratories. There was excellent concordance (98.0% overall) for diagnosis of HER2 amplification by CISH compared with FISH. Intraobserver variability (7.7%) and intersite variability (9.1%) of absolute HER2\\/chromosome enumeration probe 17 ratios were tightly controlled across all participating laboratories. The Ventana HER2 dual-color ISH assay is robust and reproducible, shows good concordance with a standard FISH assay, and complies with requirements in national and international guidelines for performance of ISH-based diagnostic tests.

  14. Multiple scattering corrections to the Beer-Lambert law. 2: Detector with a variable field of view.

    Science.gov (United States)

    Zardecki, A; Tam, W G

    1982-07-01

    The multiple scattering corrections to the Beer-Lambert law in the case of a detector with a variable field of view are analyzed. We introduce transmission functions relating the received radiant power to reference power levels relevant to two different experimental situations. In the first case, the transmission function relates the received power to a reference power level appropriate to a nonattenuating medium. In the second case, the reference power level is established by bringing the receiver to the close-up position with respect to the source. To examine the effect of the variation of the detector field of view the behavior of the gain factor is studied. Numerical results modeling the laser beam propagation in fog, cloud, and rain are presented.

  15. The influence of the number of cells scored on the sensitivity in the comet assay

    DEFF Research Database (Denmark)

    Sharma, Anoop Kumar; Soussaline, Françoise; Sallette, Jerome

    2012-01-01

    The impact on the sensitivity of the in vitro comet assay by increasing the number of cells scored has only been addressed in a few studies. The present study investigated whether the sensitivity of the assay could be improved by scoring more than 100 cells. Two cell lines and three different che...... of the assay. A two-way ANOVA analysis of variance showed that the contribution from the two variables “the number of cells scored” and “concentration” on the total variation in the coefficients of variance dataset was statistically significant (p...

  16. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    Science.gov (United States)

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective

  17. Rough multiple objective decision making

    CERN Document Server

    Xu, Jiuping

    2011-01-01

    Rough Set TheoryBasic concepts and properties of rough sets Rough Membership Rough Intervals Rough FunctionApplications of Rough SetsMultiple Objective Rough Decision Making Reverse Logistics Problem with Rough Interval Parameters MODM based Rough Approximation for Feasible RegionEVRMCCRMDCRM Reverse Logistics Network Design Problem of Suji Renewable Resource MarketBilevel Multiple Objective Rough Decision Making Hierarchical Supply Chain Planning Problem with Rough Interval Parameters Bilevel Decision Making ModelBL-EVRM BL-CCRMBL-DCRMApplication to Supply Chain Planning of Mianyang Co., LtdStochastic Multiple Objective Rough Decision Multi-Objective Resource-Constrained Project Scheduling UnderRough Random EnvironmentRandom Variable Stochastic EVRM Stochastic CCRM Stochastic DCRM Multi-Objective rc-PSP/mM/Ro-Ra for Longtan Hydropower StationFuzzy Multiple Objective Rough Decision Making Allocation Problem under Fuzzy Environment Fuzzy Variable Fu-EVRM Fu-CCRM Fu-DCRM Earth-Rock Work Allocation Problem.

  18. Molecular typing of Salmonella enterica serovar typhi isolates from various countries in Asia by a multiplex PCR assay on variable-number tandem repeats.

    Science.gov (United States)

    Liu, Yichun; Lee, May-Ann; Ooi, Eng-Eong; Mavis, Yeo; Tan, Ai-Ling; Quek, Hung-Hiang

    2003-09-01

    A multiplex PCR method incorporating primers flanking three variable-number tandem repeat (VNTR) loci (arbitrarily labeled TR1, TR2, and TR3) in the CT18 strain of Salmonella enterica serovar Typhi has been developed for molecular typing of S. enterica serovar Typhi clinical isolates from several Asian countries, including Singapore, Indonesia, India, Bangladesh, Malaysia, and Nepal. We have demonstrated that the multiplex PCR could be performed on crude cell lysates and that the VNTR banding profiles produced could be easily analyzed by visual inspection after conventional agarose gel electrophoresis. The assay was highly discriminative in identifying 49 distinct VNTR profiles among 59 individual isolates. A high level of VNTR profile heterogeneity was observed in isolates from within the same country and among countries. These VNTR profiles remained stable after the strains were passaged extensively under routine laboratory culture conditions. In contrast to the S. enterica serovar Typhi isolates, an absence of TR3 amplicons and a lack of length polymorphisms in TR1 and TR2 amplicons were observed for other S. enterica serovars, such as Salmonella enterica serovar Typhimurium, Salmonella enterica serovar Enteritidis, and Salmonella enterica serovar Paratyphi A, B, and C. DNA sequencing of the amplified VNTR regions substantiated these results, suggesting the high stability of the multiplex PCR assay. The multiplex-PCR-based VNTR profiling developed in this study provides a simple, rapid, reproducible, and high-resolution molecular tool for the epidemiological analysis of S. enterica serovar Typhi strains.

  19. An interlaboratory transfer of a multi-analyte assay between continents.

    Science.gov (United States)

    Georgiou, Alexandra; Dong, Kelly; Hughes, Stephen; Barfield, Matthew

    2015-01-01

    Alex has worked at GlaxoSmithKline for the past 15 years and currently works within the bioanalytical and toxicokinetic group in the United Kingdom. Alex's role in previous years has been the in-house support of preclinical and clinical bioanalysis, from method development through to sample analysis activities as well as acting as PI for GLP bioanalysis and toxicokinetics. For the past two years, Alex has applied this analytical and regulatory experience to focus on the outsourcing of preclinical bioanalysis, toxicokinetics and clinical bioanalysis, working closely with multiple bioanalytical and in-life CRO partners worldwide. Alex works to support DMPK and Safety Assessment outsourcing activities for GSK across multiple therapeutic areas, from the first GLP study through to late stage clinical PK studies. Transfer and cross-validation of an existing analytical assay between a laboratory providing current analytical support, and a laboratory needed for new or additional support, can present the bioanalyst with numerous challenges. These challenges can be technical or logistical in nature and may prove to be significant when transferring an assay between laboratories in different continents. Part of GlaxoSmithKline's strategy to improve confidence in providing quality data, is to cross-validate between laboratories. If the cross-validation fails predefined acceptance criteria, then a subsequent investigation would follow. This may also prove to be challenging. The importance of thorough planning and good communication throughout assay transfer, cross-validation and any subsequent investigations is illustrated in this case study.

  20. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  1. A diagnostic assay based on variable intergenic region distinguishes between Leishmania donovani and Leishmania infantum

    Czech Academy of Sciences Publication Activity Database

    Chocholová, Eva; Jirků, Milan; Lukeš, Julius

    2008-01-01

    Roč. 55, č. 1 (2008), s. 75-78 ISSN 0015-5683 R&D Projects: GA MŠk LC07032; GA MŠk 2B06129 Institutional research plan: CEZ:AV0Z60220518 Keywords : Leishmania * assay * diagnosis Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.307, year: 2008

  2. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  3. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  4. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  5. Development of in vitro assay method with radioisotope

    International Nuclear Information System (INIS)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W.; Oh, O. D.

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([ 125 I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [ 125 I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides

  6. Development of in vitro assay method with radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W. [Korea Atomic Energy Research Institute. Korea Cancer Center Hospital, Seoul (Korea, Republic of); Oh, O. D. [Yonsei University, Seoul (Korea, Republic of)

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([{sup 125}I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [{sup 125}I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides.

  7. Variable geometry Darrieus wind machine

    Science.gov (United States)

    Pytlinski, J. T.; Serrano, D.

    1983-08-01

    A variable geometry Darrieus wind machine is proposed. The lower attachment of the blades to the rotor can move freely up and down the axle allowing the blades of change shape during rotation. Experimental data for a 17 m. diameter Darrieus rotor and a theoretical model for multiple streamtube performance prediction were used to develop a computer simulation program for studying parameters that affect the machine's performance. This new variable geometry concept is described and interrelated with multiple streamtube theory through aerodynamic parameters. The computer simulation study shows that governor behavior of a Darrieus turbine can not be attained by a standard turbine operating within normally occurring rotational velocity limits. A second generation variable geometry Darrieus wind turbine which uses a telescopic blade is proposed as a potential improvement on the studied concept.

  8. Evidence for positive, but not negative, behavioral contrast with wheel-running reinforcement on multiple variable-ratio schedules.

    Science.gov (United States)

    Belke, Terry W; Pierce, W David

    2016-12-01

    Rats responded on a multiple variable-ratio (VR) 10 VR 10 schedule of reinforcement in which lever pressing was reinforced by the opportunity to run in a wheel for 30s in both the changed (manipulated) and unchanged components. To generate positive contrast, the schedule of reinforcement in the changed component was shifted to extinction; to generate negative contrast, the schedule was shifted to VR 3. With the shift to extinction in the changed component, wheel-running and local lever-pressing rates increased in the unchanged component, a result supporting positive contrast; however, the shift to a VR 3 schedule in the changed component showed no evidence of negative contrast in the unaltered setting, only wheel running decreased in the unchanged component. Changes in wheel-running rates across components were consistent in showing a compensation effect, depending on whether the schedule manipulation increased or decreased opportunities for wheel running in the changed component. These findings are the first to demonstrate positive behavioral contrast on a multiple schedule with wheel running as reinforcement in both components. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. International network for comparison of HIV neutralization assays: the NeutNet report.

    Directory of Open Access Journals (Sweden)

    Eva Maria Fenyö

    Full Text Available Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1 vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet involving 18 independent participants was organized to compare different assays.Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4 at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (virus infectivity assays, VI assays, or their Env-pseudotyped (gp160 derivatives produced in 293T cells (PSV assays from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression.PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent.The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of

  10. The comet assay: assessment of in vitro and in vivo DNA damage.

    Science.gov (United States)

    Bajpayee, Mahima; Kumar, Ashutosh; Dhawan, Alok

    2013-01-01

    Rapid industrialization and pursuance of a better life have led to an increase in the amount of chemicals in the environment, which are deleterious to human health. Pesticides, automobile exhausts, and new chemical entities all add to air pollution and have an adverse effect on all living organisms including humans. Sensitive test systems are thus required for accurate hazard identification and risk assessment. The Comet assay has been used widely as a simple, rapid, and sensitive tool for assessment of DNA damage in single cells from both in vitro and in vivo sources as well as in humans. Already, the in vivo comet assay has gained importance as the preferred test for assessing DNA damage in animals for some international regulatory guidelines. The advantages of the in vivo comet assay are its ability to detect DNA damage in any tissue, despite having non-proliferating cells, and its sensitivity to detect genotoxicity. The recommendations from the international workshops held for the comet assay have resulted in establishment of guidelines. The in vitro comet assay conducted in cultured cells and cell lines can be used for screening large number of compounds and at very low concentrations. The in vitro assay has also been automated to provide a high-throughput screening method for new chemical entities, as well as environmental samples. This chapter details the in vitro comet assay using the 96-well plate and in vivo comet assay in multiple organs of the mouse.

  11. Comparative study of the enzyme linked immunosorbent assay (ELISA) and two radioimmunoassays (RIA'S) for in-sulin

    Energy Technology Data Exchange (ETDEWEB)

    Klimes, I; Jurcovicova, J; Palkovic, M [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Ustav Experimentalnej Endokrinologie

    1978-06-30

    The results of the quality control tests for enzyme linked immunosorbent assay (ELISA) were compared with the results of two different radioimmunoassays (RIA'S) for insulin. Using the manufacturer's procedure for the ELISA kit we found that the analytical variables such as assay sensitivity, recovery study and the 50% binding intercept were in good agreement with those obtained with the RIA method.

  12. Software for optimization of SNP and PCR-RFLP genotyping to discriminate many genomes with the fewest assays

    Directory of Open Access Journals (Sweden)

    Wagner Mark C

    2005-05-01

    Full Text Available Abstract Background Microbial forensics is important in tracking the source of a pathogen, whether the disease is a naturally occurring outbreak or part of a criminal investigation. Results A method and SPR Opt (SNP and PCR-RFLP Optimization software to perform a comprehensive, whole-genome analysis to forensically discriminate multiple sequences is presented. Tools for the optimization of forensic typing using Single Nucleotide Polymorphism (SNP and PCR-Restriction Fragment Length Polymorphism (PCR-RFLP analyses across multiple isolate sequences of a species are described. The PCR-RFLP analysis includes prediction and selection of optimal primers and restriction enzymes to enable maximum isolate discrimination based on sequence information. SPR Opt calculates all SNP or PCR-RFLP variations present in the sequences, groups them into haplotypes according to their co-segregation across those sequences, and performs combinatoric analyses to determine which sets of haplotypes provide maximal discrimination among all the input sequences. Those set combinations requiring that membership in the fewest haplotypes be queried (i.e. the fewest assays be performed are found. These analyses highlight variable regions based on existing sequence data. These markers may be heterogeneous among unsequenced isolates as well, and thus may be useful for characterizing the relationships among unsequenced as well as sequenced isolates. The predictions are multi-locus. Analyses of mumps and SARS viruses are summarized. Phylogenetic trees created based on SNPs, PCR-RFLPs, and full genomes are compared for SARS virus, illustrating that purported phylogenies based only on SNP or PCR-RFLP variations do not match those based on multiple sequence alignment of the full genomes. Conclusion This is the first software to optimize the selection of forensic markers to maximize information gained from the fewest assays, accepting whole or partial genome sequence data as input. As

  13. The Propagation of Movement Variability in Time: A Methodological Approach for Discrete Movements with Multiple Degrees of Freedom

    Science.gov (United States)

    Krüger, Melanie; Straube, Andreas; Eggert, Thomas

    2017-01-01

    In recent years, theory-building in motor neuroscience and our understanding of the synergistic control of the redundant human motor system has significantly profited from the emergence of a range of different mathematical approaches to analyze the structure of movement variability. Approaches such as the Uncontrolled Manifold method or the Noise-Tolerance-Covariance decomposition method allow to detect and interpret changes in movement coordination due to e.g., learning, external task constraints or disease, by analyzing the structure of within-subject, inter-trial movement variability. Whereas, for cyclical movements (e.g., locomotion), mathematical approaches exist to investigate the propagation of movement variability in time (e.g., time series analysis), similar approaches are missing for discrete, goal-directed movements, such as reaching. Here, we propose canonical correlation analysis as a suitable method to analyze the propagation of within-subject variability across different time points during the execution of discrete movements. While similar analyses have already been applied for discrete movements with only one degree of freedom (DoF; e.g., Pearson's product-moment correlation), canonical correlation analysis allows to evaluate the coupling of inter-trial variability across different time points along the movement trajectory for multiple DoF-effector systems, such as the arm. The theoretical analysis is illustrated by empirical data from a study on reaching movements under normal and disturbed proprioception. The results show increased movement duration, decreased movement amplitude, as well as altered movement coordination under ischemia, which results in a reduced complexity of movement control. Movement endpoint variability is not increased under ischemia. This suggests that healthy adults are able to immediately and efficiently adjust the control of complex reaching movements to compensate for the loss of proprioceptive information. Further, it is

  14. A European multicenter study on the analytical performance of the VERIS HBV assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Multiple factor analysis by example using R

    CERN Document Server

    Pagès, Jérôme

    2014-01-01

    Multiple factor analysis (MFA) enables users to analyze tables of individuals and variables in which the variables are structured into quantitative, qualitative, or mixed groups. Written by the co-developer of this methodology, Multiple Factor Analysis by Example Using R brings together the theoretical and methodological aspects of MFA. It also includes examples of applications and details of how to implement MFA using an R package (FactoMineR).The first two chapters cover the basic factorial analysis methods of principal component analysis (PCA) and multiple correspondence analysis (MCA). The

  16. Sequence Optimized Real-Time RT-PCR Assay for Detection of Crimean-Congo Hemorrhagic Fever Virus

    Science.gov (United States)

    2017-03-21

    on the linear range of the curve 129 using a nonlinear regression analysis. A two-way ANOVA with Sidak’s multiple comparisons test was 130 done to...currently fielded CCHFV assay. 31 TR-17-094 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. 2 Introduction 32...analyses were performed using GraphPrism 6 (GraphPad Software, San Diego, CA). 128 Assay linearity based on the preliminary LOD was determined based

  17. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  18. Cytogenetic bio-dosimetry of an accidental exposure of a radiological worker using multiple assays

    International Nuclear Information System (INIS)

    Thierens, H.; De Ruyck, K.; Vral, A.; De Gelder, V.; Whitehouse, C. A.; Tawn, E. J.; Boesman, I.

    2005-01-01

    A technician involved in the maintenance of X-ray equipment visited the occupational medicine service with complaints of skin lesions, apparently caused by an accidental exposure three months earlier. To estimate the dose received by the technician in the accident, bio-dosimetry was performed 6 and 18 months post-exposure with the dicentric and micronucleus assays. Part of the latest blood sample was also used for retrospective dosimetry by fluorescence in situ hybridisation (FISH) analysis for translocations. The data obtained 6 and 18 months post-exposure indicate that both dicentrics and micronuclei disappear with a half-time of 1 y. After correction for delayed blood sampling, dose values of 0.75 Gy (95% confidence limits 0.56-1.05 Gy) from dicentrics and 0.96 Gy (95% confidence limits 0.79-1.18 Gy) from micronuclei were obtained. FISH analysis of translocations resulted in a dose estimate of 0.79 Gy (95% confidence limits 0.61-0.99 Gy). The satisfactory agreement between the three cytogenetic endpoints supports the use of the micronucleus assay for triage purposes in the case of large scale radiological accidents and provides further evidence for the valid use of FISH for translocations as a reliable retrospective biological dosimeter. (authors)

  19. Ecosystem stability in space: α, β and γ variability.

    Science.gov (United States)

    Wang, Shaopeng; Loreau, Michel

    2014-08-01

    The past two decades have seen great progress in understanding the mechanisms of ecosystem stability in local ecological systems. There is, however, an urgent need to extend existing knowledge to larger spatial scales to match the scale of management and conservation. Here, we develop a general theoretical framework to study the stability and variability of ecosystems at multiple scales. Analogously to the partitioning of biodiversity, we propose the concepts of alpha, beta and gamma variability. Gamma variability at regional (metacommunity) scale can be partitioned into local alpha variability and spatial beta variability, either multiplicatively or additively. On average, variability decreases from local to regional scales, which creates a negative variability-area relationship. Our partitioning framework suggests that mechanisms of regional ecosystem stability can be understood by investigating the influence of ecological factors on alpha and beta variability. Diversity can provide insurance effects at the various levels of variability, thus generating alpha, beta and gamma diversity-stability relationships. As a consequence, the loss of biodiversity and habitat impairs ecosystem stability at the regional scale. Overall, our framework enables a synthetic understanding of ecosystem stability at multiple scales and has practical implications for landscape management. © 2014 John Wiley & Sons Ltd/CNRS.

  20. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  1. Determining antioxidant activities of lactobacilli cell-free supernatants by cellular antioxidant assay: a comparison with traditional methods.

    Directory of Open Access Journals (Sweden)

    Jiali Xing

    Full Text Available Antioxidant activity of lactic acid bacteria is associated with multiple health-protective effects. Traditional indexes of chemical antioxidant activities poorly reflect the antioxidant effects of these bacteria in vivo. Cellular antioxidant activity (CAA assay was used in this study to determine the antioxidant activity of cell-free supernatants (CFSs of 10 Lactobacillus strains. The performance of the CAA assay was compared with that of four chemical antioxidant activity assays, namely, DPPH radical scavenging, hydroxyl radical scavenging (HRS, reducing power (RP, and inhibition of linoleic acid peroxidation (ILAP. Results of the CAA assay were associated with those of DPPH and ILAP assays, but not with those of RP and HRS assays. The inter- and intra-specific antioxidant activities of CFS were characterized by chemical and CAA assays. L. rhamnosus CCFM 1107 displayed a high antioxidative effect similar to positive control L. rhamnosus GG ATCC 53103 in all of the assays. The CAA assay is a potential method for the detection of antioxidant activities of lactobacilli CFSs.

  2. Validation of the Filovirus Plaque Assay for Use in Preclinical Studies

    Directory of Open Access Journals (Sweden)

    Amy C. Shurtleff

    2016-04-01

    Full Text Available A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4 studies. After standardization studies were completed, Good Laboratory Practices (GLP-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV variant and Ebola Virus Kikwit (EBOV variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID. The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies.

  3. Sequential and simultaneous multiple explanation

    Directory of Open Access Journals (Sweden)

    Robert Litchfield

    2007-02-01

    Full Text Available This paper reports two experiments comparing variants of multiple explanation applied in the early stages of a judgment task (a case involving employee theft where participants are not given a menu of response options. Because prior research has focused on situations where response options are provided to judges, we identify relevant dependent variables that an intervention might affect when such options are not given. We use these variables to build a causal model of intervention that illustrates both the intended effects of multiple explanation and some potentially competing processes that it may trigger. Although multiple explanation clearly conveys some benefits (e.g., willingness to delay action to engage in information search, increased detail, quality and confidence in alternative explanations in the present experiments, we also found evidence that it may initiate or enhance processes that attenuate its advantages (e.g., feelings that one does not need more data if one has multiple good explanations.

  4. Interlaboratory survey for T3 and T4 assays in Italy: results from a two semester period

    International Nuclear Information System (INIS)

    Pilo, A.; Zucchelli, G.C.; Chiesa, M.R.; Piro, M.A.

    1982-01-01

    The usefulness of external quality control schemes (EQCS) is generally acknowledged in clinical chemistry; these schemes allow not only the evaluation of the between-laboratory variability of the assay under study, but also make it possible the improvement of the analytical performances of the participants laboratories. Recently interlaboratory surveys have been extended to radioimmunoassays. Starting from january 1980, a national EQCS hormone assays was organized in Italy; triiodothyronine (T3) and thyroxine (T4) have been the first assays considered due to their large diffusion

  5. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  6. Multi-targeted priming for genome-wide gene expression assays

    Directory of Open Access Journals (Sweden)

    Adomas Aleksandra B

    2010-08-01

    Full Text Available Abstract Background Complementary approaches to assaying global gene expression are needed to assess gene expression in regions that are poorly assayed by current methodologies. A key component of nearly all gene expression assays is the reverse transcription of transcribed sequences that has traditionally been performed by priming the poly-A tails on many of the transcribed genes in eukaryotes with oligo-dT, or by priming RNA indiscriminately with random hexamers. We designed an algorithm to find common sequence motifs that were present within most protein-coding genes of Saccharomyces cerevisiae and of Neurospora crassa, but that were not present within their ribosomal RNA or transfer RNA genes. We then experimentally tested whether degenerately priming these motifs with multi-targeted primers improved the accuracy and completeness of transcriptomic assays. Results We discovered two multi-targeted primers that would prime a preponderance of genes in the genomes of Saccharomyces cerevisiae and Neurospora crassa while avoiding priming ribosomal RNA or transfer RNA. Examining the response of Saccharomyces cerevisiae to nitrogen deficiency and profiling Neurospora crassa early sexual development, we demonstrated that using multi-targeted primers in reverse transcription led to superior performance of microarray profiling and next-generation RNA tag sequencing. Priming with multi-targeted primers in addition to oligo-dT resulted in higher sensitivity, a larger number of well-measured genes and greater power to detect differences in gene expression. Conclusions Our results provide the most complete and detailed expression profiles of the yeast nitrogen starvation response and N. crassa early sexual development to date. Furthermore, our multi-targeting priming methodology for genome-wide gene expression assays provides selective targeting of multiple sequences and counter-selection against undesirable sequences, facilitating a more complete and

  7. Cyclotrons with fast variable and/or multiple energy extraction

    Directory of Open Access Journals (Sweden)

    C. Baumgarten

    2013-10-01

    Full Text Available We discuss the possibility in principle of stripping extraction in combination with reverse bends in isochronous separate-sector cyclotrons (and/or fixed field alternating gradient accelerators. If one uses reverse bends between the sectors (instead of or in combination with drifts and places stripper foils at the sector exit edges, the stripped beam has a reduced bending radius and it should be able to leave the cyclotron within the range of the valley—even if the beam is stripped at less than full energy. We are especially interested in stripping of H_{2}^{+}, as it doubles the charge to mass ratio of the ions. However the method could be applied to other ions or ionized molecules as well. For the production of proton beams by stripping extraction of an H_{2}^{+} beam, we discuss possible designs for three types of machines: First, a low-energy cyclotron for the simultaneous production of several beams at multiple energies—for instance 15, 30, and 70 MeV—thus allowing beam delivery on several isotope production targets. In this case it can be an advantage to have a strong energy dependence of the direction of the extracted beam. Second, we consider a fast variable-energy proton machine for cancer therapy that should allow extraction (of the complete beam at all energies in the range of about 70 MeV to about 250 MeV into the same beam line. Third, we consider a high-intensity high-energy machine, where the main design goals are extraction with low losses, low activation of components, and high reliability. Especially if such a machine is considered for an accelerator driven system (ADS, this extraction mechanism has advantages: Beam trips by the failure of electrostatic elements could be avoided and the turn separation would be less critical, which allows operation at lower main cavity voltages. This would in turn reduce the number of rf trips. The price that has to be paid for these advantages is an increase in size and/or field

  8. Multiple sporadic colorectal cancers display a unique methylation phenotype.

    Directory of Open Access Journals (Sweden)

    Victoria Gonzalo

    Full Text Available Epigenetics are thought to play a major role in the carcinogenesis of multiple sporadic colorectal cancers (CRC. Previous studies have suggested concordant DNA hypermethylation between tumor pairs. However, only a few methylation markers have been analyzed. This study was aimed at describing the epigenetic signature of multiple CRC using a genome-scale DNA methylation profiling. We analyzed 12 patients with synchronous CRC and 29 age-, sex-, and tumor location-paired patients with solitary tumors from the EPICOLON II cohort. DNA methylation profiling was performed using the Illumina Infinium HM27 DNA methylation assay. The most significant results were validated by Methylight. Tumors samples were also analyzed for the CpG Island Methylator Phenotype (CIMP; KRAS and BRAF mutations and mismatch repair deficiency status. Functional annotation clustering was performed. We identified 102 CpG sites that showed significant DNA hypermethylation in multiple tumors with respect to the solitary counterparts (difference in β value ≥0.1. Methylight assays validated the results for 4 selected genes (p = 0.0002. Eight out of 12(66.6% multiple tumors were classified as CIMP-high, as compared to 5 out of 29(17.2% solitary tumors (p = 0.004. Interestingly, 76 out of the 102 (74.5% hypermethylated CpG sites found in multiple tumors were also seen in CIMP-high tumors. Functional analysis of hypermethylated genes found in multiple tumors showed enrichment of genes involved in different tumorigenic functions. In conclusion, multiple CRC are associated with a distinct methylation phenotype, with a close association between tumor multiplicity and CIMP-high. Our results may be important to unravel the underlying mechanism of tumor multiplicity.

  9. An integrated multi-study analysis of intra-subject variability in cerebrospinal fluid amyloid-β concentrations collected by lumbar puncture and indwelling lumbar catheter

    DEFF Research Database (Denmark)

    Lucey, Brendan P; Gonzales, Celedon; Das, Ujjwas

    2015-01-01

    unknown what effect differences in CSF collection methodology have on Aβ variability. In this study, we sought to determine the effect of different collection methodologies on the stability of CSF Aβ concentrations over time. METHODS: Grouped analysis of CSF Aβ levels from multiple industry and academic...... by enzyme linked immunosorbent assay. Data from all sponsors was converted to percent of the mean for Aβ40 and Aβ42 for comparison. Repeated measures analysis of variance was performed to assess for factors affecting the linear rise of Aβ concentrations over time. RESULTS: Analysis of studies collecting CSF...

  10. Advanced statistics: linear regression, part II: multiple linear regression.

    Science.gov (United States)

    Marill, Keith A

    2004-01-01

    The applications of simple linear regression in medical research are limited, because in most situations, there are multiple relevant predictor variables. Univariate statistical techniques such as simple linear regression use a single predictor variable, and they often may be mathematically correct but clinically misleading. Multiple linear regression is a mathematical technique used to model the relationship between multiple independent predictor variables and a single dependent outcome variable. It is used in medical research to model observational data, as well as in diagnostic and therapeutic studies in which the outcome is dependent on more than one factor. Although the technique generally is limited to data that can be expressed with a linear function, it benefits from a well-developed mathematical framework that yields unique solutions and exact confidence intervals for regression coefficients. Building on Part I of this series, this article acquaints the reader with some of the important concepts in multiple regression analysis. These include multicollinearity, interaction effects, and an expansion of the discussion of inference testing, leverage, and variable transformations to multivariate models. Examples from the first article in this series are expanded on using a primarily graphic, rather than mathematical, approach. The importance of the relationships among the predictor variables and the dependence of the multivariate model coefficients on the choice of these variables are stressed. Finally, concepts in regression model building are discussed.

  11. Optimal use of tandem biotin and V5 tags in ChIP assays

    NARCIS (Netherlands)

    K.E. Kolodziej (Katarzyna); F. Pourfarzad, F. (Farzin); E. de Boer (Ernie); S. Krpic (Sanja); F.G. Grosveld (Frank); J. Strouboulis (John)

    2009-01-01

    textabstractBackground: Chromatin immunoprecipitation (ChIP) assays coupled to genome arrays (Chip-on-chip) or massive parallel sequencing (ChIP-seq) lead to the genome wide identification of binding sites of chromatin associated proteins. However, the highly variable quality of antibodies and the

  12. Products of cells from gliomas: VIII. Multiple-well immunoperoxidase assay of immunoreactivity of primary hybridoma supernatants with human glioma and brain tissue and cultured glioma cells.

    Science.gov (United States)

    McKeever, P E; Wahl, R L; Shakui, P; Jackson, G A; Letica, L H; Liebert, M; Taren, J A; Beierwaltes, W H; Hoff, J T

    1990-06-01

    To test the feasibility of primary screening of hybridoma supernatants against human glioma tissue, over 5000 combinations of hybridoma supernatants with glioma tissue, cultured glioma cells, and normal central neural tissue were screened with a new multiple-well (M-well) screening system. This is an immunoperoxidase assay system with visual endpoints for screening 20-30 hybridoma supernatants per single microscope slide. There were extensive differences between specificities to tissue and to cultured glioma cells when both were screened with M-wells and when cultured cells were screened with standard semi-automated fluorescence. Primary M-well screening with glioma tissue detected seven hybridoma supernatants that specifically identified parenchymal cells of glioma tissue and that were not detected with cultured cells. Immunoreactivities of individual supernatants for vascular components (nine supernatants), necrosis (five supernatants), and nuclei (three supernatants) were detected. Other supernatants bound multiple sites on glioma tissue and/or subpopulations of neurons and glia of normal tissue. The results show that primary screening with glioma tissue detects a number of different specificities of hybridoma supernatants to gliomas not detected by conventional screening with cultured cells. These are potentially applicable to diagnosis and therapy.

  13. Recommendations for safety testing with the in vivo comet assay.

    Science.gov (United States)

    Vasquez, Marie Z

    2012-08-30

    While the in vivo comet assay increases its role in regulatory safety testing, deliberations about the interpretation of comet data continue. Concerns can arise regarding comet assay publications with limited data from non-blind testing of positive control compounds and using protocols (e.g. dose concentrations, sample times, and tissues) known to give an expected effect. There may be a tendency towards bias when the validation or interpretation of comet assay data is based on results generated by widely accepted but non-validated assays. The greatest advantages of the comet assay are its sensitivity and its ability to detect genotoxicity in tissues and at sample times that could not previously be evaluated. Guidelines for its use and interpretation in safety testing should take these factors into account. Guidelines should be derived from objective review of data generated by blind testing of unknown compounds dosed at non-toxic concentrations and evaluated in a true safety-testing environment, where the experimental design and conclusions must be defensible. However, positive in vivo comet findings with such compounds are rarely submitted to regulatory agencies and this data is typically unavailable for publication due to its proprietary nature. To enhance the development of guidelines for safety testing with the comet assay, and with the permission of several sponsors, this paper presents and discusses relevant data from multiple GLP comet studies conducted blind, with unknown pharmaceuticals and consumer products. Based on these data and the lessons we have learned through the course of conducting these studies, I suggest significant adjustments to the current conventions, and I provide recommendations for interpreting in vivo comet assay results in situations where risk must be evaluated in the absence of carcinogenicity or clinical data. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Development of a new microtiter plate format for clinically relevant assays.

    Science.gov (United States)

    Piletska, Elena V; Piletsky, Stanislav S; Whitcombe, Michael J; Chianella, Iva; Piletsky, Sergey A

    2012-02-21

    A new format for the microtiter plate-based assays was proposed. The novelty involves the use of disk-shaped inserts for immobilization of biological and chemical reagents. The internal opening of the disks allows measurements of the reactions by standard microtiter plate readers without any additional steps involving liquid handling. Ideally the plate end-users just have to add the sample and take the measurement without any need of multiple reagent additions or transfer of the liquid to a different plate. The novel assay format also allows handling of reagents which are not soluble in an aqueous environment. As a proof of concept we describe here several model reactions which are compatible with microtiter plate format, such as monitoring enzymatic reactions catalyzed by glucose oxidase (GOx) and urease, measurements of proteins by BCA assay, analysis of pH, and concentration of antioxidants. The "mix and match" approach in the disk-shape format allows multiplexing and could be particularly useful for high throughput screening. One of the potential application areas for this novel assay format could be in a multianalyte system for measurement of clinically relevant analytes in primary care.

  15. A flow cytometric assay technology based on quantum dots-encoded beads

    International Nuclear Information System (INIS)

    Wang Haiqiao; Liu Tiancai; Cao Yuancheng; Huang Zhenli; Wang Jianhao; Li Xiuqing; Zhao Yuandi

    2006-01-01

    A flow cytometric detecting technology based on quantum dots (QDs)-encoded beads has been described. Using this technology, several QDs-encoded beads with different code were identified effectively, and the target molecule (DNA sequence) in solution was also detected accurately by coupling to its complementary sequence probed on QDs-encoded beads through DNA hybridization assay. The resolution of this technology for encoded beads is resulted from two longer wavelength fluorescence identification signals (yellow and red fluorescent signals of QDs), and the third shorter wavelength fluorescence signal (green reporting signal of fluorescein isothiocyanate (FITC)) for the determination of reaction between probe and target. In experiment, because of QDs' unique optical character, only one excitation light source was needed to excite the QDs and probe dye FITC synchronously comparing with other flow cytometric assay technology. The results show that this technology has present excellent repeatability and good accuracy. It will become a promising multiple assay platform in various application fields after further improvement

  16. Ecological and evolutionary impacts of changing climatic variability.

    Science.gov (United States)

    Vázquez, Diego P; Gianoli, Ernesto; Morris, William F; Bozinovic, Francisco

    2017-02-01

    While average temperature is likely to increase in most locations on Earth, many places will simultaneously experience higher variability in temperature, precipitation, and other climate variables. Although ecologists and evolutionary biologists widely recognize the potential impacts of changes in average climatic conditions, relatively little attention has been paid to the potential impacts of changes in climatic variability and extremes. We review the evidence on the impacts of increased climatic variability and extremes on physiological, ecological and evolutionary processes at multiple levels of biological organization, from individuals to populations and communities. Our review indicates that climatic variability can have profound influences on biological processes at multiple scales of organization. Responses to increased climatic variability and extremes are likely to be complex and cannot always be generalized, although our conceptual and methodological toolboxes allow us to make informed predictions about the likely consequences of such climatic changes. We conclude that climatic variability represents an important component of climate that deserves further attention. © 2015 Cambridge Philosophical Society.

  17. Normalization methods in time series of platelet function assays

    Science.gov (United States)

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  18. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    International Nuclear Information System (INIS)

    Ahlstedt, S.; Rylander, H.

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, 125 I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not. (author)

  19. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, S; Rylander, H [Goeteborg Univ. (Sweden)

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, /sup 125/I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not.

  20. Rapid algal toxicity assay using variable chlorophyll fluorescence for Chlorella kessleri (Chlorophyta)

    Czech Academy of Sciences Publication Activity Database

    Kvíderová, Jana

    2010-01-01

    Roč. 25, č. 6 (2010), s. 554-562 ISSN 1520-4081 R&D Projects: GA MŠk 1M0571 Institutional research plan: CEZ:AV0Z60050516 Keywords : bioassay * variable chlorophyll fluorescence * Chlorella kessleri Subject RIV: EF - Botanics Impact factor: 1.932, year: 2010

  1. Relationship between rice yield and climate variables in southwest Nigeria using multiple linear regression and support vector machine analysis

    Science.gov (United States)

    Oguntunde, Philip G.; Lischeid, Gunnar; Dietrich, Ottfried

    2018-03-01

    This study examines the variations of climate variables and rice yield and quantifies the relationships among them using multiple linear regression, principal component analysis, and support vector machine (SVM) analysis in southwest Nigeria. The climate and yield data used was for a period of 36 years between 1980 and 2015. Similar to the observed decrease ( P 1 and explained 83.1% of the total variance of predictor variables. The SVM regression function using the scores of the first principal component explained about 75% of the variance in rice yield data and linear regression about 64%. SVM regression between annual solar radiation values and yield explained 67% of the variance. Only the first component of the principal component analysis (PCA) exhibited a clear long-term trend and sometimes short-term variance similar to that of rice yield. Short-term fluctuations of the scores of the PC1 are closely coupled to those of rice yield during the 1986-1993 and the 2006-2013 periods thereby revealing the inter-annual sensitivity of rice production to climate variability. Solar radiation stands out as the climate variable of highest influence on rice yield, and the influence was especially strong during monsoon and post-monsoon periods, which correspond to the vegetative, booting, flowering, and grain filling stages in the study area. The outcome is expected to provide more in-depth regional-specific climate-rice linkage for screening of better cultivars that can positively respond to future climate fluctuations as well as providing information that may help optimized planting dates for improved radiation use efficiency in the study area.

  2. Longitudinal survey of Staphylococcus aureus in cystic fibrosis patients using a multiple-locus variable-number of tandem-repeats analysis method

    OpenAIRE

    Vergnaud Gilles; Moissenet Didier; Corvol Harriet; Fauroux Brigitte; Corbineau Gaëlle; Hormigos Katia; Vu-Thien Hoang; Pourcel Christine

    2010-01-01

    Abstract Background Staphylococcus aureus infection in patients with cystic fibrosis (CF) is frequent and may be due to colonization by a few pathogenic lineages. Systematic genotyping of all isolates, methicillin-susceptible S. aureus (MSSA) as well as methicillin-resistant S. aureus (MRSA) is necessary to identify such lineages and follow their evolution in patients. Multiple-locus variable-number tandem repeat analysis (MLVA/VNTR) was used to survey S. aureus clinical isolates in a French ...

  3. Latest Holocene Climate Variability revealed by a high-resolution multiple Proxy Record off Lisbon (Portugal)

    Science.gov (United States)

    Abrantes, F.; Lebreiro, S.; Ferreira, A.; Gil, I.; Jonsdottir, H.; Rodrigues, T.; Kissel, C.; Grimalt, J.

    2003-04-01

    The North Atlantic Oscillation (NAO) is known to have a major influence on the wintertime climate of the Atlantic basin and surrounding countries, determining precipitation and wind conditions at mid-latitudes. A comparison of Hurrel's NAO index to the mean winter (January-March) discharge of the Iberian Tagus River reveals a good negative correlation to negative NAO, while the years of largest upwelling anomalies, as referred in the literature, appear to be in good agreement with positive NAO. On this basis, a better understanding of the long-term variability of the NAO and Atlantic climate variability can be gained from high-resolution climate records from the Lisbon area. Climate variability of the last 2,000 years is assessed through a multiple proxy study of sedimentary sequences recovered from the Tagus prodelta deposition center, off Lisbon (Western Iberia). Physical properties, XRF and magnetic properties from core logging, grain size, δ18O, TOC, CaCO3, total alkenones, n-alkanes, alkenone SST, diatoms, benthic and planktonic foraminiferal assemblage compositions and fluxes are the proxies employed. The age model for site D13902 is based on AMS C-14 dates from mollusc and planktonic foraminifera shells, the reservoir correction for which was obtained by dating 3 pre-bomb, mollusc shells from the study area. Preliminary results indicate a Little Ice Age (LIA - 1300 - 1600 AD) alkenone derived SSTs around 15 degC followed by a sharp and rapid increase towards 19 degC. In spite the strong variability observed for most records, this low temperature interval is marked by a general increase in organic carbon, total alkenone concentration, diatom and foraminiferal abundances, as well as an increase in the sediment fine fraction and XRF determined Fe content, pointing to important river input and higher productivity. The Medieval Warm Period (1080 - 1300 AD) is characterized by 17-18 degC SSTs, increased mean grain size, but lower magnetic susceptibility and Fe

  4. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  5. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 2. The biological variability of the murine Local Lymph Node Assay (LLNA) for skin sensitisation.

    Science.gov (United States)

    Roberts, David W; Api, Anne Marie; Aptula, Aynur O

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the most common in vivo regulatory toxicology test for skin sensitisation, quantifying potency as the EC3, the concentration of chemical giving a threefold increase in thymidine uptake in the local lymph node. Existing LLNA data can, along with clinical data, provide useful comparator information on the potency of sensitisers. Understanding of the biological variability of data from LLNA studies is important for those developing non-animal based risk assessment approaches for skin allergy. Here an existing set of 94 EC3 values for 12 chemicals, all tested at least three times in the same vehicle have been analysed by calculating standard deviations (SD) for logEC3 values. The SDs range from 0.08 to 0.22. The overall SD for the 94 logEC3 values is 0.147. Thus the 95% confidence limits (2xSD) for LLNA EC3 values are within a factor of 2, comparable to those for physico-chemical measurements such as partition coefficients and solubility. The residual SDs of Quantitative Mechanistic Models (QMMs) based on physical organic chemistry parameters are similar to the overall SD of the LLNA, indicating that QMMs of this type are unlikely to be bettered for predictive accuracy. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Multiplexed homogeneous proximity ligation assays for high throughput protein biomarker research in serological material

    DEFF Research Database (Denmark)

    Lundberg, Martin; Thorsen, Stine Buch; Assarsson, Erika

    2011-01-01

    A high throughput protein biomarker discovery tool has been developed based on multiplexed proximity ligation assays (PLA) in a homogeneous format in the sense of no washing steps. The platform consists of four 24-plex panels profiling 74 putative biomarkers with sub pM sensitivity each consuming...... sequences are united by DNA ligation upon simultaneous target binding forming a PCR amplicon. Multiplex PLA thereby converts multiple target analytes into real-time PCR amplicons that are individually quantificatied using microfluidic high capacity qPCR in nano liter volumes. The assay shows excellent...

  7. Observed climate variability over Chad using multiple observational and reanalysis datasets

    Science.gov (United States)

    Maharana, Pyarimohan; Abdel-Lathif, Ahmat Younous; Pattnayak, Kanhu Charan

    2018-03-01

    Chad is the largest of Africa's landlocked countries and one of the least studied region of the African continent. The major portion of Chad lies in the Sahel region, which is known for its rapid climate change. In this study, multiple observational datasets are analyzed from 1950 to 2014, in order to examine the trend of precipitation and temperature along with their variability over Chad to understand possible impacts of climate change over this region. Trend analysis of the climatic fields has been carried out using Mann-Kendall test. The precipitation over Chad is mostly contributed during summer by West African Monsoon, with maximum northward limit of 18° N. The Atlantic Ocean as well as the Mediterranean Sea are the major source of moisture for the summer rainfall over Chad. Based on the rainfall time series, the entire study period has been divided in to wet (1950 to 1965), dry (1966 to 1990) and recovery period (1991 to 2014). The rainfall has decreased drastically for almost 3 decades during the dry period resulted into various drought years. The temperature increases at a rate of 0.15 °C/decade during the entire period of analysis. The seasonal rainfall as well as temperature plays a major role in the change of land use/cover. The decrease of monsoon rainfall during the dry period reduces the C4 cover drastically; this reduction of C4 grass cover leads to increase of C3 grass cover. The slow revival of rainfall is still not good enough for the increase of shrub cover but it favors the gradual reduction of bare land over Chad.

  8. Automating quantum dot barcode assays using microfluidics and magnetism for the development of a point-of-care device.

    Science.gov (United States)

    Gao, Yali; Lam, Albert W Y; Chan, Warren C W

    2013-04-24

    The impact of detecting multiple infectious diseases simultaneously at point-of-care with good sensitivity, specificity, and reproducibility would be enormous for containing the spread of diseases in both resource-limited and rich countries. Many barcoding technologies have been introduced for addressing this need as barcodes can be applied to detecting thousands of genetic and protein biomarkers simultaneously. However, the assay process is not automated and is tedious and requires skilled technicians. Barcoding technology is currently limited to use in resource-rich settings. Here we used magnetism and microfluidics technology to automate the multiple steps in a quantum dot barcode assay. The quantum dot-barcoded microbeads are sequentially (a) introduced into the chip, (b) magnetically moved to a stream containing target molecules, (c) moved back to the original stream containing secondary probes, (d) washed, and (e) finally aligned for detection. The assay requires 20 min, has a limit of detection of 1.2 nM, and can detect genetic targets for HIV, hepatitis B, and syphilis. This study provides a simple strategy to automate the entire barcode assay process and moves barcoding technologies one step closer to point-of-care applications.

  9. Toward development of a comprehensive external quality assurance program for polyfunctional intracellular cytokine staining assays.

    Science.gov (United States)

    Staats, Janet S; Enzor, Jennifer H; Sanchez, Ana M; Rountree, Wes; Chan, Cliburn; Jaimes, Maria; Chan, Ray Chun-Fai; Gaur, Amitabh; Denny, Thomas N; Weinhold, Kent J

    2014-07-01

    The External Quality Assurance Program Oversight Laboratory (EQAPOL) Flow Cytometry Program assesses the proficiency of NIH/NIAID/DAIDS-supported and potentially other interested research laboratories in performing Intracellular Cytokine Staining (ICS) assays. The goal of the EQAPOL Flow Cytometry External Quality Assurance Program (EQAP) is to provide proficiency testing and remediation for participating sites. The program is not punitive; rather, EQAPOL aims to help sites identify areas for improvement. EQAPOL utilizes a highly standardized ICS assay to minimize variability and readily identify those sites experiencing technical difficulties with their assays. Here, we report the results of External Proficiency 3 (EP3) where participating sites performed a 7-color ICS assay. On average, sites perform well in the Flow Cytometry EQAP (median score is "Good"). The most common technical issues identified by the program involve protocol adherence and data analysis; these areas have been the focus of site remediation. The EQAPOL Flow Cytometry team is now in the process of expanding the program to 8-color ICS assays. Evaluating polyfunctional ICS responses would align the program with assays currently being performed in support of HIV immune monitoring assays. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. The assay of glucocerebrosidase activity using the natural substrate

    International Nuclear Information System (INIS)

    Strasberg, P.M.; Lowden, J.A.

    1982-01-01

    The authors have examined eight published methods for the assay of glucocerebrosidase using the natural substrate glucocerebroside and tabulated the variable components and conditions while comparing these methods to their own. In each case assays were performed using a 8000 fold, partially purified human placental enzyme, having a pH optimum of 5.4-5.6 and a Ksub(m) of approximately 0.60 mmol per liter. Results were obtained by following the release of radioactive ceramide or of unlabelled glucose. In many cases published results had been based on a one- or two-hour incubation time. Apparent specific activities varied over a 70-fold difference between the various procedures. When the authors measured activities from the linear (15-30 min) portion of rate curves the values increased by 1.4 to 3 times but still ranged from 6x10 3 -180x10 3 nmol. mg -1 protein h -1 . They obtained maximum velocity using 1.2 mmol glucocerebroside, 0.5% (w/v) crude taurocholate and 2 μg enzyme protein/ml. Specific activities reported from different laboratories are not directly comparable. Conditions for assay should be optimized for the enzyme preparation to be studied. (Auth.)

  11. Coronaviruses in brain tissue from patients with multiple sclerosis

    DEFF Research Database (Denmark)

    Dessau, R B; Lisby, G; Frederiksen, J L

    2001-01-01

    Brain tissue from 25 patients with clinically definite multiple sclerosis (MS) and as controls brain tissue from 36 patients without neurological disease was tested for the presence of human coronaviral RNA. Four PCR assays with primers specific for N-protein of human coronavirus strain 229E...... and three PCR assays with primers specific for the nucleocapsid protein of human coronavirus strain OC43 were performed. Sporadic positive PCR assays were observed in both patients and controls in some of the PCR assays. However, these results were not reproducible and there was no difference...... in the proportion of positive signals from the MS patients compared to controls. Evidence for a chronic infection with the human coronaviruses strain 229E or OC43 in brain tissue from patients with MS or controls has not been found in this study....

  12. Assessing human variability in kinetics for exposures to multiple environmental chemicals: a physiologically based pharmacokinetic modeling case study with dichloromethane, benzene, toluene, ethylbenzene, and m-xylene.

    Science.gov (United States)

    Valcke, Mathieu; Haddad, Sami

    2015-01-01

    The objective of this study was to compare the magnitude of interindividual variability in internal dose for inhalation exposure to single versus multiple chemicals. Physiologically based pharmacokinetic models for adults (AD), neonates (NEO), toddlers (TODD), and pregnant women (PW) were used to simulate inhalation exposure to "low" (RfC-like) or "high" (AEGL-like) air concentrations of benzene (Bz) or dichloromethane (DCM), along with various levels of toluene alone or toluene with ethylbenzene and xylene. Monte Carlo simulations were performed and distributions of relevant internal dose metrics of either Bz or DCM were computed. Area under the blood concentration of parent compound versus time curve (AUC)-based variability in AD, TODD, and PW rose for Bz when concomitant "low" exposure to mixtures of increasing complexities occurred (coefficient of variation (CV) = 16-24%, vs. 12-15% for Bz alone), but remained unchanged considering DCM. Conversely, AUC-based CV in NEO fell (15 to 5% for Bz; 12 to 6% for DCM). Comparable trends were observed considering production of metabolites (AMET), except for NEO's CYP2E1-mediated metabolites of Bz, where an increased CV was observed (20 to 71%). For "high" exposure scenarios, Cmax-based variability of Bz and DCM remained unchanged in AD and PW, but decreased in NEO (CV= 11-16% to 2-6%) and TODD (CV= 12-13% to 7-9%). Conversely, AMET-based variability for both substrates rose in every subpopulation. This study analyzed for the first time the impact of multiple exposures on interindividual variability in toxicokinetics. Evidence indicates that this impact depends upon chemical concentrations and biochemical properties, as well as the subpopulation and internal dose metrics considered.

  13. Application of probability generating function to the essentials of nondestructive nuclear materials assay system using neutron correlation

    International Nuclear Information System (INIS)

    Hosoma, Takashi

    2017-01-01

    In the previous research (JAEA-Research 2015-009), essentials of neutron multiplicity counting mathematics were reconsidered where experiences obtained at the Plutonium Conversion Development Facility were taken into, and formulae of multiplicity distribution were algebraically derived up to septuplet using a probability generating function to make a strategic move in the future. Its principle was reported by K. Böhnel in 1985, but such a high-order expansion was the first case due to its increasing complexity. In this research, characteristics of the high-order correlation were investigated. It was found that higher-order correlation increases rapidly in response to the increase of leakage multiplication, crosses and leaves lower-order correlations behind, when leakage multiplication is > 1.3 that depends on detector efficiency and counter setting. In addition, fission rates and doubles count rates by fast neutron and by thermal neutron in their coexisting system were algebraically derived using a probability generating function again. Its principle was reported by I. Pázsit and L. Pál in 2012, but such a physical interpretation, i.e. associating their stochastic variables with fission rate, doubles count rate and leakage multiplication, is the first case. From Rossi-alpha combined distribution and measured ratio of each area obtained by Differential Die-Away Self-Interrogation (DDSI) and conventional assay data, it is possible to estimate: the number of induced fissions per unit time by fast neutron and by thermal neutron; the number of induced fissions (< 1) by one source neutron; and individual doubles count rates. During the research, a hypothesis introduced in their report was proved to be true. Provisional calculations were done for UO_2 of 1∼10 kgU containing ∼ 0.009 wt% "2"4"4Cm. (author)

  14. Flow cytometric assay detecting cytotoxicity against human endogenous retrovirus antigens expressed on cultured multiple sclerosis cells

    DEFF Research Database (Denmark)

    Møller-Larsen, A; Brudek, T; Petersen, T

    2013-01-01

    on their surface. Polyclonal antibodies against defined peptides in the Env- and Gag-regions of the HERVs were raised in rabbits and used in antibody-dependent cell-mediated cytotoxicity (ADCC) -assays. Rituximab® (Roche), a chimeric monoclonal antibody against CD20 expressed primarily on B cells, was used...

  15. Investigation of parameters that affect the success rate of microarray-based allele-specific hybridization assays.

    Directory of Open Access Journals (Sweden)

    Lena Poulsen

    Full Text Available BACKGROUND: The development of microarray-based genetic tests for diseases that are caused by known mutations is becoming increasingly important. The key obstacle to developing functional genotyping assays is that such mutations need to be genotyped regardless of their location in genomic regions. These regions include large variations in G+C content, and structural features like hairpins. METHODS/FINDINGS: We describe a rational, stable method for screening and combining assay conditions for the genetic analysis of 42 Phenylketonuria-associated mutations in the phenylalanine hydroxylase gene. The mutations are located in regions with large variations in G+C content (20-75%. Custom-made microarrays with different lengths of complementary probe sequences and spacers were hybridized with pooled PCR products of 12 exons from each of 38 individual patient DNA samples. The arrays were washed with eight buffers with different stringencies in a custom-made microfluidic system. The data were used to assess which parameters play significant roles in assay development. CONCLUSIONS: Several assay development methods found suitable probes and assay conditions for a functional test for all investigated mutation sites. Probe length, probe spacer length, and assay stringency sufficed as variable parameters in the search for a functional multiplex assay. We discuss the optimal assay development methods for several different scenarios.

  16. Improved assay for measuring heparin binding to bull sperm

    International Nuclear Information System (INIS)

    Miller, D.J.; Ax, R.L.

    1988-01-01

    The binding of heparin to sperm has been used to study capacitation and to rank relative fertility of bulls. Previous binding assays were laborious, used 10 7 sperm per assay point, and required large amounts of radiolabeled heparin. A modified heparin-binding assay is described that used only 5 x 10 4 cells per incubation well and required reduced amounts of [ 3 H] heparin. The assay was performed in 96-well Millititer plates, enabling easy incubation and filtering. Dissociation constants and concentrations of binding sites did not differ if analyzed by Scatchard plots, Woolf plots, or by log-logit transformed weighted nonlinear least squares regression, except in the case of outliers. In such cases, Scatchard analysis was more sensitive to outliers. Nonspecific binding was insignificant using nonlinear logistic fit regression and a proportion graph. The effects were tested of multiple free-thawing of sperm in either a commercial egg yolk extender, 40 mM Tris buffer with 8% glycerol, or 40 mM Tris buffer without glycerol. Freeze-thawing in extender did not affect the dissociation constant or the concentration of binding sites. However, freeze-thawing three times in 40 mM Tris reduced the concentration of binding sites and lowered the dissociation constant (raised the affinity). The inclusion of glycerol in the 40 mM Tris did not significantly affect the estimated dissociation constant or the concentration of binding sites as compared to 40 mM Tris without glycerol

  17. FB-line neutron multiplicity counter operation manual

    International Nuclear Information System (INIS)

    Langner, D.G.; Sweet, M.R.; Salazar, S.D.; Kroncke, K.E.

    1998-01-01

    This manual describes the design features, performance, and operating characteristics for the FB-Line Neutron Multiplicity Counter (FBLNMC). The FBLNMC counts neutron multiplicities to quantitatively assay plutonium in many forms, including impure scrap and waste. Monte Carlo neutronic calculations were used to design the high-efficiency (57%) detector that has 113 3 H tubes in a high-density polyethylene body. The new derandomizer circuit is included in the design to reduce deadtime. The FBLNMC can be applied to plutonium masses in the range from a few tens of grams to 5 kg; both conventional coincidence counting and multiplicity counting can be used as appropriate. This manual gives the performance data and preliminary calibration parameters for the FBLNMC

  18. Reducing the standard deviation in multiple-assay experiments where the variation matters but the absolute value does not.

    Science.gov (United States)

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A

    2013-01-01

    When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.

  19. Variability in assays used for detection of lentiviral infection in bobcats (Lynx rufus), pumas (Puma concolor), and ocelots (Leopardus pardalis)

    Science.gov (United States)

    Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.

    2007-01-01

    Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.

  20. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  1. Multicollinearity is a red herring in the search for moderator variables: A guide to interpreting moderated multiple regression models and a critique of Iacobucci, Schneider, Popovich, and Bakamitsos (2016).

    Science.gov (United States)

    McClelland, Gary H; Irwin, Julie R; Disatnik, David; Sivan, Liron

    2017-02-01

    Multicollinearity is irrelevant to the search for moderator variables, contrary to the implications of Iacobucci, Schneider, Popovich, and Bakamitsos (Behavior Research Methods, 2016, this issue). Multicollinearity is like the red herring in a mystery novel that distracts the statistical detective from the pursuit of a true moderator relationship. We show multicollinearity is completely irrelevant for tests of moderator variables. Furthermore, readers of Iacobucci et al. might be confused by a number of their errors. We note those errors, but more positively, we describe a variety of methods researchers might use to test and interpret their moderated multiple regression models, including two-stage testing, mean-centering, spotlighting, orthogonalizing, and floodlighting without regard to putative issues of multicollinearity. We cite a number of recent studies in the psychological literature in which the researchers used these methods appropriately to test, to interpret, and to report their moderated multiple regression models. We conclude with a set of recommendations for the analysis and reporting of moderated multiple regression that should help researchers better understand their models and facilitate generalizations across studies.

  2. Real-Time, Fast Neutron Coincidence Assay of Plutonium With a 4-Channel Multiplexed Analyzer and Organic Scintillators

    Science.gov (United States)

    Joyce, Malcolm J.; Gamage, Kelum A. A.; Aspinall, M. D.; Cave, F. D.; Lavietes, A.

    2014-06-01

    The design, principle of operation and the results of measurements made with a four-channel organic scintillator system are described. The system comprises four detectors and a multiplexed analyzer for the real-time parallel processing of fast neutron events. The function of the real-time, digital multiple-channel pulse-shape discrimination analyzer is described together with the results of laboratory-based measurements with 252Cf, 241Am-Li and plutonium. The analyzer is based on a single-board solution with integrated high-voltage supplies and graphical user interface. It has been developed to meet the requirements of nuclear materials assay of relevance to safeguards and security. Data are presented for the real-time coincidence assay of plutonium in terms of doubles count rate versus mass. This includes an assessment of the limiting mass uncertainty for coincidence assay based on a 100 s measurement period and samples in the range 0-50 g. Measurements of count rate versus order of multiplicity for 252Cf and 241Am-Li and combinations of both are also presented.

  3. Relationship between rice yield and climate variables in southwest Nigeria using multiple linear regression and support vector machine analysis.

    Science.gov (United States)

    Oguntunde, Philip G; Lischeid, Gunnar; Dietrich, Ottfried

    2018-03-01

    This study examines the variations of climate variables and rice yield and quantifies the relationships among them using multiple linear regression, principal component analysis, and support vector machine (SVM) analysis in southwest Nigeria. The climate and yield data used was for a period of 36 years between 1980 and 2015. Similar to the observed decrease (P  1 and explained 83.1% of the total variance of predictor variables. The SVM regression function using the scores of the first principal component explained about 75% of the variance in rice yield data and linear regression about 64%. SVM regression between annual solar radiation values and yield explained 67% of the variance. Only the first component of the principal component analysis (PCA) exhibited a clear long-term trend and sometimes short-term variance similar to that of rice yield. Short-term fluctuations of the scores of the PC1 are closely coupled to those of rice yield during the 1986-1993 and the 2006-2013 periods thereby revealing the inter-annual sensitivity of rice production to climate variability. Solar radiation stands out as the climate variable of highest influence on rice yield, and the influence was especially strong during monsoon and post-monsoon periods, which correspond to the vegetative, booting, flowering, and grain filling stages in the study area. The outcome is expected to provide more in-depth regional-specific climate-rice linkage for screening of better cultivars that can positively respond to future climate fluctuations as well as providing information that may help optimized planting dates for improved radiation use efficiency in the study area.

  4. A universal and reliable assay for molecular sex identification of three-spined sticklebacks (Gasterosteus aculeatus).

    Science.gov (United States)

    Toli, E-A; Calboli, F C F; Shikano, T; Merilä, J

    2016-11-01

    In heterogametic species, biological differences between the two sexes are ubiquitous, and hence, errors in sex identification can be a significant source of noise and bias in studies where sex-related sources of variation are of interest or need to be controlled for. We developed and validated a universal multimarker assay for reliable sex identification of three-spined sticklebacks (Gasterosteus aculeatus). The assay makes use of genotype scores from three sex-linked loci and utilizes Bayesian probabilistic inference to identify sex of the genotyped individuals. The results, validated with 286 phenotypically sexed individuals from six populations of sticklebacks representing all major genetic lineages (cf. Pacific, Atlantic and Japan Sea), indicate that in contrast to commonly used single-marker-based sex identification assays, the developed multimarker assay should be 100% accurate. As the markers in the assay can be scored from agarose gels, it provides a quick and cost-efficient tool for universal sex identification of three-spined sticklebacks. The general principle of combining information from multiple markers to improve the reliability of sex identification is transferable and can be utilized to develop and validate similar assays for other species. © 2016 John Wiley & Sons Ltd.

  5. Design of variable-weight quadratic congruence code for optical CDMA

    Science.gov (United States)

    Feng, Gang; Cheng, Wen-Qing; Chen, Fu-Jun

    2015-09-01

    A variable-weight code family referred to as variable-weight quadratic congruence code (VWQCC) is constructed by algebraic transformation for incoherent synchronous optical code division multiple access (OCDMA) systems. Compared with quadratic congruence code (QCC), VWQCC doubles the code cardinality and provides the multiple code-sets with variable code-weight. Moreover, the bit-error rate (BER) performance of VWQCC is superior to those of conventional variable-weight codes by removing or padding pulses under the same chip power assumption. The experiment results show that VWQCC can be well applied to the OCDMA with quality of service (QoS) requirements.

  6. The Chandra Source Catalog: Source Variability

    Science.gov (United States)

    Nowak, Michael; Rots, A. H.; McCollough, M. L.; Primini, F. A.; Glotfelty, K. J.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Evans, I.; Fabbiano, G.; Galle, E. C.; Gibbs, D. G., II; Grier, J. D.; Hain, R.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-09-01

    The Chandra Source Catalog (CSC) contains fields of view that have been studied with individual, uninterrupted observations that span integration times ranging from 1 ksec to 160 ksec, and a large number of which have received (multiple) repeat observations days to years later. The CSC thus offers an unprecedented look at the variability of the X-ray sky over a broad range of time scales, and across a wide diversity of variable X-ray sources: stars in the local galactic neighborhood, galactic and extragalactic X-ray binaries, Active Galactic Nuclei, etc. Here we describe the methods used to identify and quantify source variability within a single observation, and the methods used to assess the variability of a source when detected in multiple, individual observations. Three tests are used to detect source variability within a single observation: the Kolmogorov-Smirnov test and its variant, the Kuiper test, and a Bayesian approach originally suggested by Gregory and Loredo. The latter test not only provides an indicator of variability, but is also used to create a best estimate of the variable lightcurve shape. We assess the performance of these tests via simulation of statistically stationary, variable processes with arbitrary input power spectral densities (here we concentrate on results of red noise simulations) at variety of mean count rates and fractional root mean square variabilities relevant to CSC sources. We also assess the false positive rate via simulations of constant sources whose sole source of fluctuation is Poisson noise. We compare these simulations to an assessment of the variability found in real CSC sources, and estimate the variability sensitivities of the CSC.

  7. A New Cytotoxicity Assay for Brevetoxins Using Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Jennifer R. McCall

    2014-09-01

    Full Text Available Brevetoxins are a family of ladder-framed polyether toxins produced during blooms of the marine dinoflagellate, Karenia brevis. Consumption of shellfish or finfish exposed to brevetoxins can lead to the development of neurotoxic shellfish poisoning. The toxic effects of brevetoxins are believed to be due to the activation of voltage-sensitive sodium channels in cell membranes. The traditional cytotoxicity assay for detection of brevetoxins uses the Neuro-2A cell line, which must first be treated with the neurotoxins, ouabain and veratridine, in order to become sensitive to brevetoxins. In this study, we demonstrate several drawbacks of the Neuro-2A assay, which include variability for the EC50 values for brevetoxin and non-linear triphasic dose response curves. Ouabain/ veratridine-treated Neuro-2A cells do not show a typical sigmoidal dose response curve in response to brevetoxin, but rather, have a polynomial shaped curve, which makes calculating EC50 values highly variable. We describe a new fluorescence live cell imaging model, which allows for accurate calculation of cytotoxicity via nuclear staining and additional measurement of other viability parameters depending on which aspect of the cell is stained. In addition, the SJCRH30 cell line shows promise as an alternative to Neuro-2A cells for testing brevetoxins without the need for ouabain and veratridine.

  8. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  9. Variability of a "force signature" during windmill softball pitching and relationship between discrete force variables and pitch velocity.

    Science.gov (United States)

    Nimphius, Sophia; McGuigan, Michael R; Suchomel, Timothy J; Newton, Robert U

    2016-06-01

    This study assessed reliability of discrete ground reaction force (GRF) variables over multiple pitching trials, investigated the relationships between discrete GRF variables and pitch velocity (PV) and assessed the variability of the "force signature" or continuous force-time curve during the pitching motion of windmill softball pitchers. Intraclass correlation coefficient (ICC) for all discrete variables was high (0.86-0.99) while the coefficient of variance (CV) was low (1.4-5.2%). Two discrete variables were significantly correlated to PV; second vertical peak force (r(5)=0.81, p=0.03) and time between peak forces (r(5)=-0.79; p=0.03). High ICCs and low CVs support the reliability of discrete GRF and PV variables over multiple trials and significant correlations indicate there is a relationship between the ability to produce force and the timing of this force production with PV. The mean of all pitchers' curve-average standard deviation of their continuous force-time curves demonstrated low variability (CV=4.4%) indicating a repeatable and identifiable "force signature" pattern during this motion. As such, the continuous force-time curve in addition to discrete GRF variables should be examined in future research as a potential method to monitor or explain changes in pitching performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  11. Biotin Switch Assays for Quantitation of Reversible Cysteine Oxidation.

    Science.gov (United States)

    Li, R; Kast, J

    2017-01-01

    Thiol groups in protein cysteine residues can be subjected to different oxidative modifications by reactive oxygen/nitrogen species. Reversible cysteine oxidation, including S-nitrosylation, S-sulfenylation, S-glutathionylation, and disulfide formation, modulate multiple biological functions, such as enzyme catalysis, antioxidant, and other signaling pathways. However, the biological relevance of reversible cysteine oxidation is typically underestimated, in part due to the low abundance and high reactivity of some of these modifications, and the lack of methods to enrich and quantify them. To facilitate future research efforts, this chapter describes detailed procedures to target the different modifications using mass spectrometry-based biotin switch assays. By switching the modification of interest to a biotin moiety, these assays leverage the high affinity between biotin and avidin to enrich the modification. The use of stable isotope labeling and a range of selective reducing agents facilitate the quantitation of individual as well as total reversible cysteine oxidation. The biotin switch assay has been widely applied to the quantitative analysis of S-nitrosylation in different disease models and is now also emerging as a valuable research tool for other oxidative cysteine modifications, highlighting its relevance as a versatile, robust strategy for carrying out in-depth studies in redox proteomics. © 2017 Elsevier Inc. All rights reserved.

  12. Genetic Variability of Macrophomina phaseolina Isolates from Dry Beans in Turkey

    OpenAIRE

    Serkan Yeşil; Kubilay Kurtuluş Baştaş

    2016-01-01

    Charcoal rot is a soil and seed borne, economically important fungal disease on dry bean in Turkey. Twenty bean isolates of M. phaseolina collected from different locations in Turkey during 2008 and 2012 years were studied for genetic variability using random amplified polymorphic DNA (RAPD) assay, chlorate sensitivity on medium supplemented with 120mM of potassium, phenotype of colony, and pathogenicity. Isolates were identified as M. phaseolina based on morhological features and PCR assays ...

  13. Validation and Application of a Dried Blood Spot Ceftriaxone Assay

    Science.gov (United States)

    Page-Sharp, Madhu; Nunn, Troy; Salman, Sam; Moore, Brioni R.; Batty, Kevin T.; Davis, Timothy M. E.

    2015-01-01

    Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic/pharmacodynamic (PK/PD) studies in situations where venous blood sampling is logistically and/or ethically problematic. In this study, we aimed to develop, validate, and apply a DBS ceftriaxone assay. A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) DBS ceftriaxone assay was assessed for matrix effects, process efficiency, recovery, variability, and limits of quantification (LOQ) and detection (LOD). The effects of hematocrit, protein binding, red cell partitioning, and chad positioning were evaluated, and thermal stability was assessed. Plasma, DBS, and cell pellet ceftriaxone concentrations in 10 healthy adults were compared, and plasma concentration-time profiles of DBS and plasma ceftriaxone were incorporated into population PK models. The LOQ and LOD for ceftriaxone in DBS were 0.14 mg/liter and 0.05 mg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations (r > 0.95, P 95% initial concentrations in DBS for 14 h, 35 h, 30 days, 21 weeks, and >11 months, respectively. The present DBS ceftriaxone assay is robust and can be used as a surrogate for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including in studies of young children and of those in remote or resource-poor settings. PMID:26438505

  14. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay

    Science.gov (United States)

    Zhao, Yong; Wang, Haoran; Zhang, Pingping; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Yang, Ruifu; Wang, Chengbin; Zhou, Lei

    2016-01-01

    The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 104 CFU mL−1 or 105 CFU mL−1 for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R2) of 0.916–0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water. PMID:26884128

  15. A MIQE-compliant real-time PCR assay for Aspergillus detection.

    Directory of Open Access Journals (Sweden)

    Gemma L Johnson

    Full Text Available The polymerase chain reaction (PCR is widely used as a diagnostic tool in clinical laboratories and is particularly effective for detecting and identifying infectious agents for which routine culture and microscopy methods are inadequate. Invasive fungal disease (IFD is a major cause of morbidity and mortality in immunosuppressed patients, and optimal diagnostic criteria are contentious. Although PCR-based methods have long been used for the diagnosis of invasive aspergillosis (IA, variable performance in clinical practice has limited their value. This shortcoming is a consequence of differing sample selection, collection and preparation protocols coupled with a lack of standardisation of the PCR itself. Furthermore, it has become clear that the performance of PCR-based assays in general is compromised by the inadequacy of experimental controls, insufficient optimisation of assay performance as well as lack of transparency in reporting experimental details. The recently published "Minimum Information for the publication of real-time Quantitative PCR Experiments" (MIQE guidelines provide a blueprint for good PCR assay design and unambiguous reporting of experimental detail and results. We report the first real-time quantitative PCR (qPCR assay targeting Aspergillus species that has been designed, optimised and validated in strict compliance with the MIQE guidelines. The hydrolysis probe-based assay, designed to target the 18S rRNA DNA sequence of Aspergillus species, has an efficiency of 100% (range 95-107%, a dynamic range of at least six orders of magnitude and limits of quantification and detection of 6 and 0.6 Aspergillus fumigatus genomes, respectively. It does not amplify Candida, Scedosporium, Fusarium or Rhizopus species and its clinical sensitivity is demonstrated in histological material from proven IA cases, as well as concordant PCR and galactomannan data in matched broncho-alveolar lavage and blood samples. The robustness

  16. The M Word: Multicollinearity in Multiple Regression.

    Science.gov (United States)

    Morrow-Howell, Nancy

    1994-01-01

    Notes that existence of substantial correlation between two or more independent variables creates problems of multicollinearity in multiple regression. Discusses multicollinearity problem in social work research in which independent variables are usually intercorrelated. Clarifies problems created by multicollinearity, explains detection of…

  17. Psychosocial and Quality of Life in Women Receiving the 21-Gene Recurrence Score Assay: The Impact of Decision Style in Women with Intermediate RS

    International Nuclear Information System (INIS)

    Sulayman, N.; Spellman, E.; Graves, K. D.; Peshkin, B. N.; Isaacs, C.; Schwartz, M. D.; O’Neill, S. C.

    2012-01-01

    Multigene assays such as the 21-gene recurrence score (RS) quantify risk for recurrence and potential benefit from chemotherapy in early-stage, ER+ breast cancers. Few studies have assessed the impact of testing on patient-reported outcomes such as cancer-related distress or quality of life. The few studies that have assessed these outcomes do not consider potential modifiers, such as the patients’ level of involvement in the treatment decision-making process. In the current study, 81 breast cancer patients who received the RS assay completed cross-sectional surveys. We used linear multiple regression to assess whether test result, decision-making role (passive versus shared/active), and their interaction contributed to current levels of distress, quality of life, and decisional conflict. There were no associations between these variables and test result or decision-making role. However, women who received an intermediate RS and took a passive role in their care reported higher-cancer-related distress and cancer worry and lower quality of life than those who took a shared or active role. These data should be confirmed in prospective samples, as these poorer outcomes could be amenable to intervention

  18. Psychosocial and Quality of Life in Women Receiving the 21-Gene Recurrence Score Assay: The Impact of Decision Style in Women with Intermediate RS

    Directory of Open Access Journals (Sweden)

    Nadiyah Sulayman

    2012-01-01

    Full Text Available Multigene assays such as the 21-gene recurrence score (RS quantify risk for recurrence and potential benefit from chemotherapy in early-stage, ER+ breast cancers. Few studies have assessed the impact of testing on patient-reported outcomes such as cancer-related distress or quality of life. The few studies that have assessed these outcomes do not consider potential modifiers, such as the patients’ level of involvement in the treatment decision-making process. In the current study, 81 breast cancer patients who received the RS assay completed cross-sectional surveys. We used linear multiple regression to assess whether test result, decision-making role (passive versus shared/active, and their interaction contributed to current levels of distress, quality of life, and decisional conflict. There were no associations between these variables and test result or decision-making role. However, women who received an intermediate RS and took a passive role in their care reported higher-cancer-related distress and cancer worry and lower quality of life than those who took a shared or active role. These data should be confirmed in prospective samples, as these poorer outcomes could be amenable to intervention.

  19. The influence of talker and foreign-accent variability on spoken word identification.

    Science.gov (United States)

    Bent, Tessa; Holt, Rachael Frush

    2013-03-01

    In spoken word identification and memory tasks, stimulus variability from numerous sources impairs performance. In the current study, the influence of foreign-accent variability on spoken word identification was evaluated in two experiments. Experiment 1 used a between-subjects design to test word identification in noise in single-talker and two multiple-talker conditions: multiple talkers with the same accent and multiple talkers with different accents. Identification performance was highest in the single-talker condition, but there was no difference between the single-accent and multiple-accent conditions. Experiment 2 further explored word recognition for multiple talkers in single-accent versus multiple-accent conditions using a mixed design. A detriment to word recognition was observed in the multiple-accent condition compared to the single-accent condition, but the effect differed across the language backgrounds tested. These results demonstrate that the processing of foreign-accent variation may influence word recognition in ways similar to other sources of variability (e.g., speaking rate or style) in that the inclusion of multiple foreign accents can result in a small but significant performance decrement beyond the multiple-talker effect.

  20. Assay strategies and methods for phospholipases

    International Nuclear Information System (INIS)

    Reynolds, L.J.; Washburn, W.N.; Deems, R.A.; Dennis, E.A.

    1991-01-01

    Of the general considerations discussed, the two issues which are most important in choosing an assay are (1) what sensitivity is required to assay a particular enzyme and (2) whether the assay must be continuous. One can narrow the options further by considering substrate availability, enzyme specificity, assay convenience, or the presence of incompatible side reactions. In addition, the specific preference of a particular phospholipase for polar head group, micellar versus vesicular substrates, and anionic versus nonionic detergents may further restrict the options. Of the many assays described in this chapter, several have limited applicability or serious drawbacks and are not commonly employed. The most commonly used phospholipase assays are the radioactive TLC assay and the pH-stat assay. The TLC assay is probably the most accurate, sensitive assay available. These aspects often outweigh the disadvantages of being discontinuous, tedious, and expensive. The radioactive E. coli assay has become popular recently as an alternative to the TLC assay for the purification of the mammalian nonpancreatic phospholipases. The assay is less time consuming and less expensive than the TLC assay, but it is not appropriate when careful kinetics are required. Where less sensitivity is needed, or when a continuous assay is necessary, the pH-stat assay is often employed. With purified enzymes, when free thiol groups are not present, a spectrophotometric thiol assay can be used. This assay is ∼ as sensitive as the pH-stat assay but is more convenient and more reproducible, although the substrate is not available commercially. Despite the many assay choices available, the search continues for a convenient, generally applicable assay that is both sensitive and continuous

  1. Effects of (α,n) contaminants and sample multiplication on statistical neutron correlation measurements

    International Nuclear Information System (INIS)

    Dowdy, E.J.; Hansen, G.E.; Robba, A.A.; Pratt, J.C.

    1980-01-01

    The complete formalism for the use of statistical neutron fluctuation measurements for the nondestructive assay of fissionable materials has been developed. This formalism includes the effect of detector deadtime, neutron multiplicity, random neutron pulse contributions from (α,n) contaminants in the sample, and the sample multiplication of both fission-related and background neutrons

  2. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  3. Visual variability affects early verb learning.

    Science.gov (United States)

    Twomey, Katherine E; Lush, Lauren; Pearce, Ruth; Horst, Jessica S

    2014-09-01

    Research demonstrates that within-category visual variability facilitates noun learning; however, the effect of visual variability on verb learning is unknown. We habituated 24-month-old children to a novel verb paired with an animated star-shaped actor. Across multiple trials, children saw either a single action from an action category (identical actions condition, for example, travelling while repeatedly changing into a circle shape) or multiple actions from that action category (variable actions condition, for example, travelling while changing into a circle shape, then a square shape, then a triangle shape). Four test trials followed habituation. One paired the habituated verb with a new action from the habituated category (e.g., 'dacking' + pentagon shape) and one with a completely novel action (e.g., 'dacking' + leg movement). The others paired a new verb with a new same-category action (e.g., 'keefing' + pentagon shape), or a completely novel category action (e.g., 'keefing' + leg movement). Although all children discriminated novel verb/action pairs, children in the identical actions condition discriminated trials that included the completely novel verb, while children in the variable actions condition discriminated the out-of-category action. These data suggest that - as in noun learning - visual variability affects verb learning and children's ability to form action categories. © 2014 The British Psychological Society.

  4. Improvement in latent variable indirect response modeling of multiple categorical clinical endpoints: application to modeling of guselkumab treatment effects in psoriatic patients.

    Science.gov (United States)

    Hu, Chuanpu; Randazzo, Bruce; Sharma, Amarnath; Zhou, Honghui

    2017-10-01

    Exposure-response modeling plays an important role in optimizing dose and dosing regimens during clinical drug development. The modeling of multiple endpoints is made possible in part by recent progress in latent variable indirect response (IDR) modeling for ordered categorical endpoints. This manuscript aims to investigate the level of improvement achievable by jointly modeling two such endpoints in the latent variable IDR modeling framework through the sharing of model parameters. This is illustrated with an application to the exposure-response of guselkumab, a human IgG1 monoclonal antibody in clinical development that blocks IL-23. A Phase 2b study was conducted in 238 patients with psoriasis for which disease severity was assessed using Psoriasis Area and Severity Index (PASI) and Physician's Global Assessment (PGA) scores. A latent variable Type I IDR model was developed to evaluate the therapeutic effect of guselkumab dosing on 75, 90 and 100% improvement of PASI scores from baseline and PGA scores, with placebo effect empirically modeled. The results showed that the joint model is able to describe the observed data better with fewer parameters compared with the common approach of separately modeling the endpoints.

  5. Vitamin D assays: past and present debates, difficulties, and developments.

    Science.gov (United States)

    Fraser, William D; Milan, Anna M

    2013-02-01

    Clinical interest in Vitamin D and its purported roles not only in calcium and bone metabolism but in several other medical conditions (diabetes, cardiovascular disease, multiple sclerosis, cancer, psychiatric disorders, neuro-muscular disease) has led to a surge in laboratory requests for 25 hydroxy vitamin D and 1,25 dihydroxy vitamin D measurement. Circulating 25 hydroxy vitamin D concentration is routinely used as the best indicator of vitamin D status, but measurement of other metabolites, especially the physiologically active 1,25 dihyroxy vitamin D, are of clinical value. Over the last 40 years the development of assays for vitamin D and its metabolites from early competitive binding assays through to immunoassay and liquid chromatography aligned to mass spectrometry have demonstrated various analytical challenges, the advantages and disadvantages of each method are constantly changing with new technological developments. Immunoassay remains the predominant mode of measurement for 25-hydroxy vitamin D although problems with equimolar recovery of the D2 and D3 metabolites remain an issue. Standardisation of all assays has been improved but not resolved with the currently available reference materials as evidenced by the international vitamin D external quality assurance scheme, DEQAS. The choice of method for each laboratory remains a balance mainly between turn around time, convenience, cost and the specificity and accuracy of the information obtained. With increasing discussion and clinical interest surrounding other vitamin D metabolites the vitamin D assay debate is set to continue.

  6. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay.

    Science.gov (United States)

    Lordkipanidzé, Marie; Lowe, Gillian C; Kirkby, Nicholas S; Chan, Melissa V; Lundberg, Martina H; Morgan, Neil V; Bem, Danai; Nisar, Shaista P; Leo, Vincenzo C; Jones, Matthew L; Mundell, Stuart J; Daly, Martina E; Mumford, Andrew D; Warner, Timothy D; Watson, Steve P

    2014-02-20

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167.

  7. Intrinsic Variability in Multiple Systems and Clusters: Open Questions

    Science.gov (United States)

    Lampens, P.

    2006-04-01

    It is most interesting and rewarding to probe the stellar structure of stars which belong to a system originating from the same parent cloud as this provides additional and more accurate constraints for the models. New results on pulsating components in multiple systems and clusters are beginning to emerge regularly. Based on concrete studies, I will present still unsolved problems and discuss some of the issues which may affect our understanding of the pulsation physics in such systems but also in general.

  8. Development of a Multiple Loci Variable Number of Tandem Repeats Analysis (MLVA) to Unravel the Intra-Pathovar Structure of Pseudomonas syringae pv. actinidiae Populations Worldwide

    Science.gov (United States)

    Ciarroni, Serena; Gallipoli, Lorenzo; Taratufolo, Maria C.; Butler, Margi I.; Poulter, Russell T. M.; Pourcel, Christine; Vergnaud, Gilles; Balestra, Giorgio M.; Mazzaglia, Angelo

    2015-01-01

    The bacterial canker of kiwifruit by Pseudomonas syringae pv. actinidiae is an emblematic example of a catastrophic disease of fruit crops. In 2008 a new, extremely virulent form of the pathogen emerged and rapidly devastated many Actinidia spp. orchards all over the world. In order to understand differences in populations within this pathovar and to elucidate their diffusion and movements on world scale, it is necessary to be able to quickly and on a routine basis compare new isolates with previous records. In this report a worldwide collection of 142 strains was analyzed by MLVA, chosen as investigative technique for its efficacy, reproducibility, simplicity and low cost. A panel of 13 Variable Number of Tandem Repeats (VNTR) loci was identified and used to describe the pathogen population. The MLVA clustering is highly congruent with the population structure as previously established by other molecular approaches including whole genome sequencing and correlates with geographic origin, time of isolation and virulence. For convenience, we divided the VNTR loci in two panels. Panel 1 assay, using six loci, recognizes 23 different haplotypes, clustered into ten complexes with highest congruence with previous classifications. Panel 2, with seven VNTR loci, provides discriminatory power. Using the total set of 13 VNTR loci, 58 haplotypes can be distinguished. The recent hypervirulent type shows very limited diversity and includes, beside the strains from Europe, New Zealand and Chile, a few strains from Shaanxi, China. A broad genetic variability is observed in China, but different types are also retrievable in Japan and Korea. The low virulent strains cluster together and are very different from the other MLVA genotypes. Data were used to generate a public database in MLVAbank. MLVA represents a very promising first-line assay for large-scale routine genotyping, prior to whole genome sequencing of only the most relevant samples. PMID:26262683

  9. OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Nicholson, Andrew D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

  10. Ratio of involved/uninvolved immunoglobulin quantification by Hevylite™ assay: clinical and prognostic impact in multiple myeloma

    Directory of Open Access Journals (Sweden)

    Koulieris Efstathios

    2012-04-01

    Full Text Available Abstract Background HevyLite™ is a new, recently developed method that facilitates separate quantification of the kappa- and lambda-bounded amounts of a given immunoglobulin (Ig. Using this method, we measured intact immunoglobulin (heavy/light chain; HLC IgG-kappa, IgG-lambda, IgA-kappa, IgA-lambda individually, as well as their deriving ratios (HLCR in a series of IgG or IgA multiple myeloma (MM patients, to investigate and assess the contribution of these tests to disease evaluation. Patients and methods HevyLite™ assays were used in sera from 130 healthy individuals (HI and 103 MM patients, at time of diagnosis. In patients, the level of paraprotein was IgG in 78 (52 IgG-kappa, 26 IgG-lambda and IgΑ in 25 (13 IgΑ-kappa, 12 IgΑ-lambda. Durie-Salmon and International Staging System stages were evenly distributed. Symptomatic patients (n = 77 received treatment while asymptomatic ones (n = 26 were followed. Patients' median follow-up was at 32.6 months. HLCR was calculated with the involved Ig (either G or A as numerator. Results In HI, median IgG-kappa was 6.85, IgG-lambda 3.81, IgA-kappa 1.19 and IgA-lambda 0.98 g/L. The corresponding median involving HLC values in MM patients were 25.8, 23.45, 28.9 and 36.4 g/L. HLC-IgG related to anemia, high serum free light chain ratio and extensive bone marrow infiltration, while high HLCR correlated with the same plus increased β2-microglobulin. In addition, increased HLCR and the presence of immunoparesis correlated with time to treatment. Patients with high HLCR had a significantly shorter survival (p = 0.022; HLCR retained its prognostic value in multivariate analysis. Conclusions HLC and HLCR quantify the precise amount of the involved immunoglobulin more accurately than other methods; moreover, they carry prognostic information regarding survival in MM patients.

  11. Differences in quantification of DNA double-strand breaks assessed by 53BP1/γH2AX focus formation assays and the comet assay in mammalian cells treated with irradiation and N-acetyl-L-cysteine

    International Nuclear Information System (INIS)

    Kurashige, Tomomi; Shimamura, Mika; Nagayama, Yuji

    2016-01-01

    The biological effect of ionizing radiation (IR) on genomic DNA is thought to be either direct or indirect; the latter is mediated by IR induction of free radicals and reactive oxygen species (ROS). This study was designed to evaluate the effect of N-acetyl-L-cysteine (NAC), a well-known ROS-scavenging antioxidant, on IR induction of genotoxicity, cytotoxicity and ROS production in mammalian cells, and aimed to clarify the conflicting data in previous publications. Although we clearly demonstrate the beneficial effect of NAC on IR-induced genotoxicity and cytotoxicity (determined using the micronucleus assay and cell viability/clonogenic assays), the data on NAC's effect on DNA double-strand break (DSB) formation were inconsistent in different assays. Specifically, mitigation of IR-induced DSBs by NAC was readily detected by the neutral comet assay, but not by the γH2AX or 53BP1 focus assays. NAC is a glutathione precursor and exerts its effect after conversion to glutathione, and presumably it has its own biological activity. Assuming that the focus assay reflects the biological responses to DSBs (detection and repair), while the comet assay reflects the physical status of genomic DNA, our results indicate that the comet assay could readily detect the antioxidant effect of NAC on DSB formation. However, NAC's biological effect might affect the detection of DSB repair by the focus assays. Our data illustrate that multiple parameters should be carefully used to analyze DNA damage when studying potential candidates for radioprotective compounds

  12. Open innovation for phenotypic drug discovery: The PD2 assay panel.

    Science.gov (United States)

    Lee, Jonathan A; Chu, Shaoyou; Willard, Francis S; Cox, Karen L; Sells Galvin, Rachelle J; Peery, Robert B; Oliver, Sarah E; Oler, Jennifer; Meredith, Tamika D; Heidler, Steven A; Gough, Wendy H; Husain, Saba; Palkowitz, Alan D; Moxham, Christopher M

    2011-07-01

    Phenotypic lead generation strategies seek to identify compounds that modulate complex, physiologically relevant systems, an approach that is complementary to traditional, target-directed strategies. Unlike gene-specific assays, phenotypic assays interrogate multiple molecular targets and signaling pathways in a target "agnostic" fashion, which may reveal novel functions for well-studied proteins and discover new pathways of therapeutic value. Significantly, existing compound libraries may not have sufficient chemical diversity to fully leverage a phenotypic strategy. To address this issue, Eli Lilly and Company launched the Phenotypic Drug Discovery Initiative (PD(2)), a model of open innovation whereby external research groups can submit compounds for testing in a panel of Lilly phenotypic assays. This communication describes the statistical validation, operations, and initial screening results from the first PD(2) assay panel. Analysis of PD(2) submissions indicates that chemical diversity from open source collaborations complements internal sources. Screening results for the first 4691 compounds submitted to PD(2) have confirmed hit rates from 1.6% to 10%, with the majority of active compounds exhibiting acceptable potency and selectivity. Phenotypic lead generation strategies, in conjunction with novel chemical diversity obtained via open-source initiatives such as PD(2), may provide a means to identify compounds that modulate biology by novel mechanisms and expand the innovation potential of drug discovery.

  13. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  14. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  15. Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B

    2016-08-01

    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.

  16. On Thermally Interacting Multiple Boreholes with Variable Heating Strength: Comparison between Analytical and Numerical Approaches

    Directory of Open Access Journals (Sweden)

    Marc A. Rosen

    2012-08-01

    Full Text Available The temperature response in the soil surrounding multiple boreholes is evaluated analytically and numerically. The assumption of constant heat flux along the borehole wall is examined by coupling the problem to the heat transfer problem inside the borehole and presenting a model with variable heat flux along the borehole length. In the analytical approach, a line source of heat with a finite length is used to model the conduction of heat in the soil surrounding the boreholes. In the numerical method, a finite volume method in a three dimensional meshed domain is used. In order to determine the heat flux boundary condition, the analytical quasi-three-dimensional solution to the heat transfer problem of the U-tube configuration inside the borehole is used. This solution takes into account the variation in heating strength along the borehole length due to the temperature variation of the fluid running in the U-tube. Thus, critical depths at which thermal interaction occurs can be determined. Finally, in order to examine the validity of the numerical method, a comparison is made with the results of line source method.

  17. Towards an operational definition of Essential Biodiversity Variables

    NARCIS (Netherlands)

    Schmeller, D.S.; Mihoub, J.-B.; Bowser, A.; Arvanitidis, C.; Costello, M.J.; Fernandez, M.; Geller, G.N.; Hobern, D.; Kissling, W.D.; Regan, E.; Saarenmaa, H.; Turak, E.; Isaac, N.J.B.

    2017-01-01

    The concept of essential biodiversity variables (EBVs) was proposed in 2013 to improve harmonization of biodiversity data into meaningful metrics. EBVs were conceived as a small set of variables which collectively capture biodiversity change at multiple spatial scales and within time intervals that

  18. Standardization of automated 25-hydroxyvitamin D assays: How successful is it?

    Science.gov (United States)

    Elsenberg, E H A M; Ten Boekel, E; Huijgen, H; Heijboer, A C

    2017-12-01

    Multiple 25(OH)D assays have recently been aligned to improve comparibility. In this study we investigated the performance of these assays using both native single-donor sera with target values certified by a reference method as well as single donor sera from a heterogeneous patient population. 25(OH)D levels were measured in twenty reference samples (Ref!25OHD; Labquality, Finland) using five automated methods (Lumipulse, Liaison, Cobas, iSYS and Access) and one aligned ID-XLC-MS/MS method (slope: 1,00; intercept: 0,00; R=0,996). Furthermore, 25(OH)D concentrations measured in 50 pregnant women and 52 random patients using the 5 automated assays were compared to the ID-XLC-MS/MS. In addition, Vitamin D binding protein (DBP) was measured. Most automated assays showed significant differences in 25(OH)D levels measured in reference samples. Slopes varied from 1,00 to 1,33, intercepts from -5.48 to -15,81nmol/L and the R from 0,971 to 0,997. This inaccuracy was even more prominent in a heterogeneous patient population. Slopes varied from 0,75 to 1,35, intercepts from -9.02 to 11,51nmol/L and the R from 0,840 to 0,949. For most assays the deviation in 25(OH)D concentration increased with elevating DBP concentrations suggesting that DBP might be one of the factors contributing to the inaccuracy in currently used automated 25(OH)D methods. Despite the use of standardized assays, we observed significant differences in 25(OH)D concentrations in some automated methods using reference material obtained from healthy single donor sera. In sera of a patient population this inaccuracy was even worse which is highly concerning as patient samples are being investigated in clinical laboratories. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  20. Results of in vitro chemosensitivity assays

    International Nuclear Information System (INIS)

    Tanigawa, Nobuhiko; Morimoto, Hideki; Akita, Toshiaki; Inoue, Hiroshi; Tanaka, Takeo.

    1986-01-01

    The authors reviewed their experiences to date with chemosensitivity testing of 629 tumors by human tumor clonogenic assay (HTCA) and of 199 tumors by scintillation assay (SA). HTCA and SA were both performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Overall, 60 % of specimens in HTCA and 58 % in SA produced significant growth in vitro. HTCA was 52 % (13/25) reliable for predicting in vivo sensitivity, and 95 % (36/38) reliable for in vivo resistance, whereas SA was 40 % (8/20) reliable for in vivo sensitivity and 88 % (21/24) for in vivo resistance. In vitro success rates were variable, depending on the tumor histology. In vitro growth of gastric cancer specimens was characteristically lower than that of colon cancer specimens (48 % and 60 % in HTCA, and 46 % and 68 % in SA, respectively). (p < 0.005). Optimal in vitro-in vivo drug concentrations and culture conditions are still being defined. Correlation studies of in vitro-in vivo responses of gastrointestinal cancers suggested that in vitro concentrations of 5-fluorouracil and mitomycin C used in this study were considerably higher than their optimal doses. Tumor cell heterogeneity poses significant problems in the clinical use of chemosensitivity assays. In this last study, we sought evidence of tumor heterogeneity by comparing chemosensitivity responses between : 1) different portions of a single tumor, 2) a primary and a metastatic biopsy taken from a patient on the same day, and 3) different metastases from a patient taken on the same day. The results demonstrated the presence of considerable heterogeneity of response to chemotherapy among different tumors from the same patient, and even within the same tumor. The reported discrepancies of in vitro and in vivo sensitivity may be due to such therapeutic heterogeneity among tumors. (J.P.N.)

  1. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  2. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-01-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (μg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r = 0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r = 0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA

  3. A ring test of in vitro neutral detergent fiber digestibility: Analytical variability and sample ranking

    Science.gov (United States)

    In vitro neutral detergent fiber (NDF) digestibility (NDFD) is an empirical measurement used to describe fermentability of NDF by rumen microbes. Variability is inherent in assays and affects the precision that can be expected for replicated samples. The study objective was to evaluate variability w...

  4. Disclosing bias in bisulfite assay: MethPrimers underestimate high DNA methylation.

    Directory of Open Access Journals (Sweden)

    Andrea Fuso

    Full Text Available Discordant results obtained in bisulfite assays using MethPrimers (PCR primers designed using MethPrimer software or assuming that non-CpGs cytosines are non methylated versus primers insensitive to cytosine methylation lead us to hypothesize a technical bias. We therefore used the two kinds of primers to study different experimental models and methylation statuses. We demonstrated that MethPrimers negatively select hypermethylated DNA sequences in the PCR step of the bisulfite assay, resulting in CpG methylation underestimation and non-CpG methylation masking, failing to evidence differential methylation statuses. We also describe the characteristics of "Methylation-Insensitive Primers" (MIPs, having degenerated bases (G/A to cope with the uncertain C/U conversion. As CpG and non-CpG DNA methylation patterns are largely variable depending on the species, developmental stage, tissue and cell type, a variable extent of the bias is expected. The more the methylome is methylated, the greater is the extent of the bias, with a prevalent effect of non-CpG methylation. These findings suggest a revision of several DNA methylation patterns so far documented and also point out the necessity of applying unbiased analyses to the increasing number of epigenomic studies.

  5. ‘Domesticating’ low carbon thermal technologies: Diversity, multiplicity and variability in older person, off grid households

    International Nuclear Information System (INIS)

    Wrapson, Wendy; Devine-Wright, Patrick

    2014-01-01

    The uptake of low carbon heating technologies forms an important part of government strategies to reduce carbon emissions. Yet our understanding of why such technologies are adopted and how they are engaged with post-adoption, particularly by older adults living in off-grid areas, is limited. Drawing on a contextualised, socio-technical approach to domestic heating, we present findings from 51 in-depth interviews with a sample of 17 older person households in the South West of England, with ages ranging from 60 to 89 years. Diverse and multiple configurations of heating devices and fuels were found that varied considerably, with some households using five different fuels. The design of the study ensured that approximately half the sample used some form of low carbon thermal technology, such as heat pumps and biomass boilers. Many factors were reported to influence the adoption of low carbon heating; environmental motives were not primary influences and the avoidance of financial risks associated with ‘peak oil’ was expressed. Low carbon thermal technologies were typically integrated into rather than replaced existing heating systems so that valued services provided by conventional technologies could be retained. Implications of the findings for policies to reduce carbon emissions, particularly in older adult, off-grid households, are discussed. - Highlights: • We interviewed 17 households with conventional/low carbon thermal technologies (LCTTs) in South West England. • Older adult, off grid households commonly use multiple, diverse and variable heating technologies and fuels. • Reducing fuel costs was a key reason for installing LCTTs. • LCTTs more commonly were integrated with, rather than replaced, conventional technologies. • Expected reductions in domestic carbon emissions due to LCTTs may not be realised

  6. SUMMIT (Serially Unified Multicenter Multiple Sclerosis Investigation): creating a repository of deeply phenotyped contemporary multiple sclerosis cohorts.

    Science.gov (United States)

    Bove, Riley; Chitnis, Tanuja; Cree, Bruce Ac; Tintoré, Mar; Naegelin, Yvonne; Uitdehaag, Bernard Mj; Kappos, Ludwig; Khoury, Samia J; Montalban, Xavier; Hauser, Stephen L; Weiner, Howard L

    2017-08-01

    There is a pressing need for robust longitudinal cohort studies in the modern treatment era of multiple sclerosis. Build a multiple sclerosis (MS) cohort repository to capture the variability of disability accumulation, as well as provide the depth of characterization (clinical, radiologic, genetic, biospecimens) required to adequately model and ultimately predict a patient's course. Serially Unified Multicenter Multiple Sclerosis Investigation (SUMMIT) is an international multi-center, prospectively enrolled cohort with over a decade of comprehensive follow-up on more than 1000 patients from two large North American academic MS Centers (Brigham and Women's Hospital (Comprehensive Longitudinal Investigation of Multiple Sclerosis at the Brigham and Women's Hospital (CLIMB; BWH)) and University of California, San Francisco (Expression/genomics, Proteomics, Imaging, and Clinical (EPIC))). It is bringing online more than 2500 patients from additional international MS Centers (Basel (Universitätsspital Basel (UHB)), VU University Medical Center MS Center Amsterdam (MSCA), Multiple Sclerosis Center of Catalonia-Vall d'Hebron Hospital (Barcelona clinically isolated syndrome (CIS) cohort), and American University of Beirut Medical Center (AUBMC-Multiple Sclerosis Interdisciplinary Research (AMIR)). We provide evidence for harmonization of two of the initial cohorts in terms of the characterization of demographics, disease, and treatment-related variables; demonstrate several proof-of-principle analyses examining genetic and radiologic predictors of disease progression; and discuss the steps involved in expanding SUMMIT into a repository accessible to the broader scientific community.

  7. Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.

    Science.gov (United States)

    Winborn, Jessica; Kerrigan, Sarah

    2017-06-01

    Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Adenovirus 2, Bordetella bronchiseptica, and Parainfluenza Molecular Diagnostic Assay Results in Puppies After vaccination with Modified Live Vaccines.

    Science.gov (United States)

    Ruch-Gallie, R; Moroff, S; Lappin, M R

    2016-01-01

    Canine adenovirus 2, parainfluenza, and Bordetella bronchiseptica cause respiratory disease in dogs, and each has a modified live intranasal vaccine available. Molecular diagnostic assays to amplify specific nucleic acids are available for each of these agents. If positive molecular diagnostic assay results are common after vaccination, the positive predictive value of the diagnostic assays for disease would be decreased. To determine the impact of administration of commercially available modified live topical adenovirus 2, B. bronchiseptica, and parainfluenza vaccine has on the results of a commercially available PCR panel. Eight puppies from a research breeding facility negative for these pathogens. Blinded prospective pilot study. Puppies were vaccinated with a single dose of modified live topical adenovirus 2, B. bronchiseptica, and parainfluenza and parenteral dose of adenovirus 2, canine distemper virus, and parvovirus. Nasal and pharyngeal swabs were collected on multiple days and submitted for PCR assay. Nucleic acids of all 3 organisms contained in the topical vaccine were detected from both samples multiple times through 28 days after vaccination with higher numbers of positive samples detected between days 3 and 10 after vaccination. Vaccine status should be considered when interpreting respiratory agent PCR results if modified live vaccines have been used. Development of quantitative PCR and wild-type sequencing are necessary to improve positive predictive value of these assays by distinguishing vaccinate from natural infection. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. Electrochemiluminescence assays for insulin and glutamic acid decarboxylase autoantibodies improve prediction of type 1 diabetes risk.

    Science.gov (United States)

    Miao, Dongmei; Steck, Andrea K; Zhang, Li; Guyer, K Michelle; Jiang, Ling; Armstrong, Taylor; Muller, Sarah M; Krischer, Jeffrey; Rewers, Marian; Yu, Liping

    2015-02-01

    We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs.

  10. Evaluation and selection of tandem repeat loci for a Brucella MLVA typing assay

    Directory of Open Access Journals (Sweden)

    Denoeud France

    2006-02-01

    Full Text Available Abstract Background The classification of Brucella into species and biovars relies on phenotypic characteristics and sometimes raises difficulties in the interpretation of the results due to an absence of standardization of the typing reagents. In addition, the resolution of this biotyping is moderate and requires the manipulation of the living agent. More efficient DNA-based methods are needed, and this work explores the suitability of multiple locus variable number tandem repeats analysis (MLVA for both typing and species identification. Results Eighty tandem repeat loci predicted to be polymorphic by genome sequence analysis of three available Brucella genome sequences were tested for polymorphism by genotyping 21 Brucella strains (18 reference strains representing the six 'classical' species and all biovars as well as 3 marine mammal strains currently recognized as members of two new species. The MLVA data efficiently cluster the strains as expected according to their species and biovar. For practical use, a subset of 15 loci preserving this clustering was selected and applied to the typing of 236 isolates. Using this MLVA-15 assay, the clusters generated correspond to the classical biotyping scheme of Brucella spp. The 15 markers have been divided into two groups, one comprising 8 user-friendly minisatellite markers with a good species identification capability (panel 1 and another complementary group of 7 microsatellite markers with higher discriminatory power (panel 2. Conclusion The MLVA-15 assay can be applied to large collections of Brucella strains with automated or manual procedures, and can be proposed as a complement, or even a substitute, of classical biotyping methods. This is facilitated by the fact that MLVA is based on non-infectious material (DNA whereas the biotyping procedure itself requires the manipulation of the living agent. The data produced can be queried on a dedicated MLVA web service site.

  11. The Danish National Multiple Myeloma Registry

    DEFF Research Database (Denmark)

    Gimsing, Peter; Holmström, Morten Orebo; Klausen, Tobias Wirenfelt

    2016-01-01

    AIM: The Danish National Multiple Myeloma Registry (DMMR) is a population-based clinical quality database established in January 2005. The primary aim of the database is to ensure that diagnosis and treatment of plasma cell dyscrasia are of uniform quality throughout the country. Another aim...... diagnosed patients with multiple myeloma (MM), smoldering MM, solitary plasmacytomas, and plasma cell leukemia in Denmark are registered annually; ~350 patients. Amyloid light-chain amyloidosis, POEMS syndrome (polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome......), monoclonal gammopathy of undetermined significance and monoclonal gammopathy of undetermined significance with polyneuropathy have been registered since 2014. MAIN VARIABLES: The main registered variables at diagnosis are patient demographics, baseline disease characteristics, myeloma-defining events...

  12. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  13. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    International Nuclear Information System (INIS)

    Tobin, Stephen Joseph; Fugate, Michael Lynn; Trellue, Holly Renee; DeBaere, Paul; Sjoland, Anders; Liljenfeldt, Henrik; Hu, Jianwei; Backstrom, Ulrika; Bengtsson, Martin; Burr, Tomas; Eliasson, Annika; Favalli, Andrea; Gauld, Ian; Grogan, Brandon; Jansson, Peter; Junell, Henrik; Schwalbach, Peter; Vaccaro, Stefano; Vo, Duc Ta; Wildestrand, Henrik

    2016-01-01

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  14. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fugate, Michael Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trellue, Holly Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeBaere, Paul [DG Energy, Luxembourg (Germany); Sjoland, Anders [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Liljenfeldt, Henrik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Backstrom, Ulrika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Bengtsson, Martin [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Burr, Tomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); International Atomic Energy Agency, Vienna (Austria); Eliasson, Annika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gauld, Ian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Grogan, Brandon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jansson, Peter [Uppsala Univ. (Sweden); Junell, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Schwalbach, Peter [DG Energy, Luxembourg (Germany); Vaccaro, Stefano [DG Energy, Luxembourg (Germany); Vo, Duc Ta [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wildestrand, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden)

    2016-10-28

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  15. Comparison of colorimetric assays with quantitative amino acid analysis for protein quantification of Generalized Modules for Membrane Antigens (GMMA).

    Science.gov (United States)

    Rossi, Omar; Maggiore, Luana; Necchi, Francesca; Koeberling, Oliver; MacLennan, Calman A; Saul, Allan; Gerke, Christiane

    2015-01-01

    Genetically induced outer membrane particles from Gram-negative bacteria, called Generalized Modules for Membrane Antigens (GMMA), are being investigated as vaccines. Rapid methods are required for estimating the protein content for in-process assays during production. Since GMMA are complex biological structures containing lipid and polysaccharide as well as protein, protein determinations are not necessarily straightforward. We compared protein quantification by Bradford, Lowry, and Non-Interfering assays using bovine serum albumin (BSA) as standard with quantitative amino acid (AA) analysis, the most accurate currently available method for protein quantification. The Lowry assay has the lowest inter- and intra-assay variation and gives the best linearity between protein amount and absorbance. In all three assays, the color yield (optical density per mass of protein) of GMMA was markedly different from that of BSA with a ratio of approximately 4 for the Bradford assay, and highly variable between different GMMA; and approximately 0.7 for the Lowry and Non-Interfering assays, highlighting the need for calibrating the standard used in the colorimetric assay against GMMA quantified by AA analysis. In terms of a combination of ease, reproducibility, and proportionality of protein measurement, and comparability between samples, the Lowry assay was superior to Bradford and Non-Interfering assays for GMMA quantification.

  16. The Relationship between Different Assays for Detection and Quantification of Amyloid Beta 42 in Human Cerebrospinal Fluid

    Directory of Open Access Journals (Sweden)

    Teresa A. Ellis

    2012-01-01

    Full Text Available Alzheimer's disease (AD, which is characterized by a degeneration of neurons and their synapses, is one of the most common forms of dementia. CSF levels of amyloid 42 (A42 have been recognized as a strong candidate to serve as an AD biomarker. There are a number of commercial assays that are routinely employed for measuring A42; however, these assays give diverse ranges for the absolute levels of CSF A42. In order to employ CSF A42 as a biomarker across multiple laboratories, studies need to be performed to understand the relationship between the different platforms. We have analyzed CSF samples from both diseased and nondiseased subjects with two different widely used assay platforms. The results showed that different values for the levels of CSF A42 were reported, depending on the assay used. Nonetheless, both assays clearly demonstrated statistically significant differences in the levels of A42 in CSF from AD relative to age-matched controls (AMC. This paper provides essential data for establishing the relationship between these assays and provides an important step towards the validation of A42 as a biomarker for AD.

  17. Management strategy in pregnancies with elevated second-trimester maternal serum alpha-fetoprotein based on a second assay.

    Science.gov (United States)

    Spaggiari, Emmanuel; Ruas, Marie; Dreux, Sophie; Valat, Anne-Sylvie; Czerkiewicz, Isabelle; Guimiot, Fabien; Schmitz, Thomas; Delezoide, Anne-Lise; Muller, Françoise

    2013-04-01

    To assess maternal-fetal outcomes in pregnancies associated with persistently elevated second-trimester maternal serum alpha-fetoprotein. A retrospective cohort study in 658 patients with maternal serum alpha-fetoprotein ≥2.5 multiple of median, performed at routine Down syndrome screening. Maternal serum alpha-fetoprotein was assayed a second time in 341 of them. Outcomes were recorded in all cases. The group with unexplained maternal serum alpha-fetoprotein persistently ≥2.5 multiple of median was associated with more pregnancy complications 37 of 92 (40.2%) as fetal death, preeclampsia, intrauterine growth restriction, and congenital nephrotic syndrome, compared with the group with maternal serum alpha-fetoprotein that returned to a normal level 37 of 226 (16.4%) (P alpha-fetoprotein returns to a normal level on a second assay, the risk of adverse outcome significantly decreases, but these pregnancies are still at risk of complications and therefore need close surveillance. Repeat maternal serum alpha-fetoprotein assay allows identification of patients who should be offered amniocentesis to evaluate the risk of nephrotic syndrome and epidermolysis bullosa. Alpha-fetoprotein should be monitored in pregnancies associated with unexplained high maternal serum alpha-fetoprotein. A management strategy based on ultrasound examination, second maternal serum alpha-fetoprotein assay and amniocentesis is proposed to improve prenatal counseling and management of such pregnancies. However, a prospective study remains necessary to evaluate it. Copyright © 2013 Mosby, Inc. All rights reserved.

  18. Challenges of Non-Destructive Assay Waste Measurement

    International Nuclear Information System (INIS)

    Shull, A.H.

    2003-01-01

    Historically, the Savannah River Site (SRS) routinely produced special nuclear material (SNM), which provided stable measurement conditions for the non-destructive assay (NDA) methods. However, the main mission of SRS has changed from the production of SNM to the processing of waste and material stabilization. Currently, the purpose of processing is to recover the SNM from the waste and stabilization materials, much of which is from other DOE facilities. These missions are usually of a short duration, but require non-destructive assay (NDA) accountability measurements on materials of varying composition and geometric configuration. These missions usually have cost and time constraints, which sometimes require re-application of existing NDA methods to waste measurements. Usually, each new material or re-application of the NDA method to a different SNM campaign requires new standards and timely re-calibration of the method. These constraints provide numerous challenges for the NDA methods, particularly in the area of measurement uncertainty. This paper will discuss the challenges of these situations, mainly from a measurement and statistical point of view and provide some possible solutions to the problems encountered. Specific examples will be discussed for the segmented gamma scanner (SGS), neutron multiplicity counter (NMC) and passive neutron coincidence counter (PNCC), which are some of the most common NDA instruments at SRS

  19. Gait Characteristics in Adolescents With Multiple Sclerosis.

    Science.gov (United States)

    Kalron, Alon; Frid, Lior; Menascu, Shay

    2017-03-01

    Multiple sclerosis is a progressive autoimmune disease of the central nervous system. A presentation of multiple sclerosis before age18 years has traditionally been thought to be rare. However, during the past decade, more cases have been reported. We examined gait characteristics in 24 adolescents with multiple sclerosis (12 girls, 12 boys). Mean disease duration was 20.4 (S.D. = 24.9) months and mean age was 15.5 (S.D. = 1.1) years. The mean expanded disability status scale score was 1.7 (S.D. = 0.7) indicating minimal disability. Outcomes were compared with gait and the gait variability index value of healthy age-matched adolescents. Adolescents with multiple sclerosis walked slower with a wider base of support compared with age-matched healthy control subjects. Moreover, the gait variability index was lower in the multiple sclerosis group compared with the values in the healthy adolescents: 85.4 (S.D. = 8.1) versus 96.5 (S.D. = 7.4). We present gait parameters of adolescents with multiple sclerosis. From a clinical standpoint, our data could improve management of walking dysfunction in this relatively young population. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Seasonal Variability of Aragonite Saturation State in the North Pacific Ocean Predicted by Multiple Linear Regression

    Science.gov (United States)

    Kim, T. W.; Park, G. H.

    2014-12-01

    Seasonal variation of aragonite saturation state (Ωarag) in the North Pacific Ocean (NPO) was investigated, using multiple linear regression (MLR) models produced from the PACIFICA (Pacific Ocean interior carbon) dataset. Data within depth ranges of 50-1200m were used to derive MLR models, and three parameters (potential temperature, nitrate, and apparent oxygen utilization (AOU)) were chosen as predictor variables because these parameters are associated with vertical mixing, DIC (dissolved inorganic carbon) removal and release which all affect Ωarag in water column directly or indirectly. The PACIFICA dataset was divided into 5° × 5° grids, and a MLR model was produced in each grid, giving total 145 independent MLR models over the NPO. Mean RMSE (root mean square error) and r2 (coefficient of determination) of all derived MLR models were approximately 0.09 and 0.96, respectively. Then the obtained MLR coefficients for each of predictor variables and an intercept were interpolated over the study area, thereby making possible to allocate MLR coefficients to data-sparse ocean regions. Predictability from the interpolated coefficients was evaluated using Hawaiian time-series data, and as a result mean residual between measured and predicted Ωarag values was approximately 0.08, which is less than the mean RMSE of our MLR models. The interpolated MLR coefficients were combined with seasonal climatology of World Ocean Atlas 2013 (1° × 1°) to produce seasonal Ωarag distributions over various depths. Large seasonal variability in Ωarag was manifested in the mid-latitude Western NPO (24-40°N, 130-180°E) and low-latitude Eastern NPO (0-12°N, 115-150°W). In the Western NPO, seasonal fluctuations of water column stratification appeared to be responsible for the seasonal variation in Ωarag (~ 0.5 at 50 m) because it closely followed temperature variations in a layer of 0-75 m. In contrast, remineralization of organic matter was the main cause for the seasonal

  1. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Directory of Open Access Journals (Sweden)

    Leo Heyndrickx

    Full Text Available BACKGROUND: Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s can provide measures of protective immunity. An international collaboration (NeutNet involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs and soluble CD4 (Phase I study. METHODS: In the present study (Phase II, polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (Virus Infectivity Assays, VIA, or Env (gp160-pseudotyped viruses (pseudoviruses, PSV produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP reporter gene expression. FINDINGS: Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014. Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. CONCLUSIONS: Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus

  2. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Science.gov (United States)

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus. Consistent with the Phase I study, we recommend

  3. Differences in quantification of DNA double-strand breaks assessed by 53BP1/γH2AX focus formation assays and the comet assay in mammalian cells treated with irradiation and N-acetyl-L-cysteine.

    Science.gov (United States)

    Kurashige, Tomomi; Shimamura, Mika; Nagayama, Yuji

    2016-06-01

    The biological effect of ionizing radiation (IR) on genomic DNA is thought to be either direct or indirect; the latter is mediated by IR induction of free radicals and reactive oxygen species (ROS). This study was designed to evaluate the effect of N-acetyl-L-cysteine (NAC), a well-known ROS-scavenging antioxidant, on IR induction of genotoxicity, cytotoxicity and ROS production in mammalian cells, and aimed to clarify the conflicting data in previous publications. Although we clearly demonstrate the beneficial effect of NAC on IR-induced genotoxicity and cytotoxicity (determined using the micronucleus assay and cell viability/clonogenic assays), the data on NAC's effect on DNA double-strand break (DSB) formation were inconsistent in different assays. Specifically, mitigation of IR-induced DSBs by NAC was readily detected by the neutral comet assay, but not by the γH2AX or 53BP1 focus assays. NAC is a glutathione precursor and exerts its effect after conversion to glutathione, and presumably it has its own biological activity. Assuming that the focus assay reflects the biological responses to DSBs (detection and repair), while the comet assay reflects the physical status of genomic DNA, our results indicate that the comet assay could readily detect the antioxidant effect of NAC on DSB formation. However, NAC's biological effect might affect the detection of DSB repair by the focus assays. Our data illustrate that multiple parameters should be carefully used to analyze DNA damage when studying potential candidates for radioprotective compounds. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  4. Neuromyelitis optica immunoglobulin G in Chinese patients detected by immunofluorescence assay on a monkey brain substrate.

    Science.gov (United States)

    Long, Youming; Hu, Xueqiang; Peng, Fuhua; Lu, Zhengqi; Wang, Yuge; Yang, Yu; Qiu, Wei

    2012-01-01

    Serum neuromyelitis optica immunoglobulin G (NMO-IgG) is used as a biomarker to differentiate between neuromyelitis optica (NMO) and multiple sclerosis (MS). However, the original assay is expensive and complex and shows low sensitivity. Here, we investigated the potential of NMO-IgG detection using an indirect immunofluorescence (IIF) assay on monkey brains. NMO-IgG seroprevalence was determined in 168 samples by an IIF assay on a monkey brain substrate. The data were compared with those from a standard mouse brain IIF assay using McNemar and kappa tests. Thirty-one of 50 (62%) NMO patients, 7 of 18 (38.9%) longitudinally extensive transverse myelitis patients, 6 of 57 (10.5%) MS patients, and 5 of 10 (50%) optic neuritis patients were seropositive for NMO-IgG. None of the acute partial transverse myelitis patients (n = 3) or healthy controls (n = 20) was positive. Thus, the sensitivity of the test was 62% for the patients with clinically definite NMO. The specificity was 89.5%, considering the 57 MS patients as the control group. The modified IIF assay on monkey brains and the standard IIF assay based on mouse brains were not significantly different (McNemar test; p = 1.000). The two assays were concordant in 39 seropositive samples and 100 seronegative samples (kappa test; kappa = 0.592, p monkey brain assay was no better than the standard mouse brain IIF assay, we affirmed that NMO-IgG is a sensitive and specific biomarker to differentiate between NMO and MS. Copyright © 2011 S. Karger AG, Basel.

  5. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  6. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  7. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    Science.gov (United States)

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  8. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  9. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  10. In vitro versus in vivo concordance: a case study of the replacement of an animal potency test with an immunochemical assay.

    Science.gov (United States)

    Schofield, T

    2002-01-01

    Early in its development, the potency of Merck's recombinant hepatitis B vaccine, RECOMBIVAX HB, was monitored using an assay performed in mice. A specification was determined to be the lowest potency which induced acceptable response in clinical trials. As a post-licensing commitment, Merck was asked to replace its mouse potency assay with an in vitro procedure for product release in the US market. Early studies with a commercial enzyme immunoassay (EIA) yielded highly variable results. That assay, combined with a sample pretreatment step, proved more dependable and predictive of potency in the mouse assay. Based on measurements made on manufactured materials, combined with experiments contrived to yield a wide range of reactivity in the two assays, concordance was established between the EIA and the mouse potency assay. This concordance was used to calibrate a specification for the in vitro assay that is predictive of a satisfactory response in vivo. Data from clinical trials established a correspondence between human immunogenicity and these potency markers.

  11. A technique for combining neutron and gamma-ray data into a single assay value

    International Nuclear Information System (INIS)

    Pickrell, M.M.; Mercer, D.; Sharpe, T.J.

    1998-01-01

    The authors explored the potentials of using both neutron and gamma-ray measurements on a single item and combining these data into a single assay value. The purpose was to improve assay capability for sample matrices that are difficult to measure. They chose an empirical approach because they wanted to address difficult-to-measure items for which the assay problem is complex. They used the tomographic gamma scanner; a passive, high-efficiency neutron counter with add-a-source and multiplicity; and an active neutron, californium shuffler to obtain measurements. Twenty-four 200-L drums were measured with various matrices using all three machines. The matrices were chosen specifically to spain the difficult-to-measure assay problems for some or all of the instruments. For example, the authors measured a drum filled with concrete and another filled with metal. The data from these measurements were analyzed using the alternating conditional expectation algorithm, which is one of a class of generalized additive models. Other data fusion algorithms are also possible and are being explored. The intent was to find ways to combine the data that would reduce the matrix-induced measurement error

  12. The pH of chemistry assays plays an important role in monoclonal immunoglobulin interferences.

    Science.gov (United States)

    Alberti, Michael O; Drake, Thomas A; Song, Lu

    2015-12-01

    Immunoglobulin paraproteins can interfere with multiple chemistry assays. We want to investigate the mechanisms of immunoglobulin interference. Serum samples containing paraproteins from the index patient and eight additional patients were used to investigate the interference with the creatinine and total protein assays on the Beckman Coulter AU5400/2700 analyzer, and to determine the effects of pH and ionic strength on the precipitation of different immunoglobulins in these patient samples. The paraprotein interference with the creatinine and total protein assays was caused by the precipitation of IgM paraprotein in the index patient's samples under alkaline assay conditions. At extremely high pH (12-13) and extremely low pH (1-2) and low ionic strength, paraprotein formed large aggregates in samples from the index patient but not from other patients. The pH and ionic strength are the key factors that contribute to protein aggregation and precipitation which interfere with the creatinine and total protein measurements on AU5400/2700. The different amino acid sequence of each monoclonal paraprotein will determine the pH and ionic strength at which the paraprotein will precipitate.

  13. Validation of a quantitative cerebrospinal fluid alpha-synuclein assay in a European-wide interlaboratory study

    DEFF Research Database (Denmark)

    Kruse, N.; Persson, S.; Alcolea, D.

    2015-01-01

    (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when...... the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings...... assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program -Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits...

  14. Statistical precision of delayed-neutron nondestructive assay techniques

    International Nuclear Information System (INIS)

    Bayne, C.K.; McNeany, S.R.

    1979-02-01

    A theoretical analysis of the statistical precision of delayed-neutron nondestructive assay instruments is presented. Such instruments measure the fissile content of nuclear fuel samples by neutron irradiation and delayed-neutron detection. The precision of these techniques is limited by the statistical nature of the nuclear decay process, but the precision can be optimized by proper selection of system operating parameters. Our method is a three-part analysis. We first present differential--difference equations describing the fundamental physics of the measurements. We then derive and present complete analytical solutions to these equations. Final equations governing the expected number and variance of delayed-neutron counts were computer programmed to calculate the relative statistical precision of specific system operating parameters. Our results show that Poisson statistics do not govern the number of counts accumulated in multiple irradiation-count cycles and that, in general, maximum count precision does not correspond with maximum count as first expected. Covariance between the counts of individual cycles must be considered in determining the optimum number of irradiation-count cycles and the optimum irradiation-to-count time ratio. For the assay system in use at ORNL, covariance effects are small, but for systems with short irradiation-to-count transition times, covariance effects force the optimum number of irradiation-count cycles to be half those giving maximum count. We conclude that the equations governing the expected value and variance of delayed-neutron counts have been derived in closed form. These have been computerized and can be used to select optimum operating parameters for delayed-neutron assay devices

  15. Analysis of Genome-Wide Association Studies with Multiple Outcomes Using Penalization

    Science.gov (United States)

    Liu, Jin; Huang, Jian; Ma, Shuangge

    2012-01-01

    Genome-wide association studies have been extensively conducted, searching for markers for biologically meaningful outcomes and phenotypes. Penalization methods have been adopted in the analysis of the joint effects of a large number of SNPs (single nucleotide polymorphisms) and marker identification. This study is partly motivated by the analysis of heterogeneous stock mice dataset, in which multiple correlated phenotypes and a large number of SNPs are available. Existing penalization methods designed to analyze a single response variable cannot accommodate the correlation among multiple response variables. With multiple response variables sharing the same set of markers, joint modeling is first employed to accommodate the correlation. The group Lasso approach is adopted to select markers associated with all the outcome variables. An efficient computational algorithm is developed. Simulation study and analysis of the heterogeneous stock mice dataset show that the proposed method can outperform existing penalization methods. PMID:23272092

  16. Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination

    NARCIS (Netherlands)

    Anckaert, E.; Öktem, M.; Thies, A.; Cohen-Bacrie, M.; Daan, N. M P; Schiettecatte, J.; Müller, C.; Topcu, D.; Gröning, A.; Ternaux, F.; Engel, C.; Engelmann, S.; Milczynski, C.

    2016-01-01

    Objectives: Anti-Müllerian hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The

  17. Multiplicity distributions for p-barp collisions

    International Nuclear Information System (INIS)

    Huang, D.W.; Yen, E.

    1988-01-01

    The multiplicity distribution for P-barP collisions at √s = 540 GeV is written as the sum of Poisson distributions at different impact parameter b. An energy independent relation between the variable z-bar and b is suggested. With this relation, the multiplicity distributions at √s = 200 and 900 GeV are described well. The distribution at √s = 1600 GeV is predicted

  18. mma: An R Package for Mediation Analysis with Multiple Mediators

    Directory of Open Access Journals (Sweden)

    Qingzhao Yu

    2017-04-01

    Full Text Available Mediation refers to the effect transmitted by mediators that intervene in the relationship between an exposure and a response variable. Mediation analysis has been broadly studied in many fields. However, it remains a challenge for researchers to consider complicated associations among variables and to differentiate individual effects from multiple mediators. [1] proposed general definitions of mediation effects that were adaptable to all different types of response (categorical or continuous, exposure, or mediation variables. With these definitions, multiple mediators of different types can be considered simultaneously, and the indirect effects carried by individual mediators can be separated from the total effect. Moreover, the derived mediation analysis can be performed with general predictive models. That is, the relationships among variables can be modeled using not only generalized linear models but also nonparametric models such as the Multiple Additive Regression Trees. Therefore, more complicated variable transformations and interactions can be considered in analyzing the mediation effects. The proposed method is realized by the R package 'mma'. We illustrate in this paper the proposed method and how to use 'mma' to estimate mediation effects and make inferences.

  19. Applicability of bioanalysis of multiple analytes in drug discovery and development: review of select case studies including assay development considerations.

    Science.gov (United States)

    Srinivas, Nuggehally R

    2006-05-01

    The development of sound bioanalytical method(s) is of paramount importance during the process of drug discovery and development culminating in a marketing approval. Although the bioanalytical procedure(s) originally developed during the discovery stage may not necessarily be fit to support the drug development scenario, they may be suitably modified and validated, as deemed necessary. Several reviews have appeared over the years describing analytical approaches including various techniques, detection systems, automation tools that are available for an effective separation, enhanced selectivity and sensitivity for quantitation of many analytes. The intention of this review is to cover various key areas where analytical method development becomes necessary during different stages of drug discovery research and development process. The key areas covered in this article with relevant case studies include: (a) simultaneous assay for parent compound and metabolites that are purported to display pharmacological activity; (b) bioanalytical procedures for determination of multiple drugs in combating a disease; (c) analytical measurement of chirality aspects in the pharmacokinetics, metabolism and biotransformation investigations; (d) drug monitoring for therapeutic benefits and/or occupational hazard; (e) analysis of drugs from complex and/or less frequently used matrices; (f) analytical determination during in vitro experiments (metabolism and permeability related) and in situ intestinal perfusion experiments; (g) determination of a major metabolite as a surrogate for the parent molecule; (h) analytical approaches for universal determination of CYP450 probe substrates and metabolites; (i) analytical applicability to prodrug evaluations-simultaneous determination of prodrug, parent and metabolites; (j) quantitative determination of parent compound and/or phase II metabolite(s) via direct or indirect approaches; (k) applicability in analysis of multiple compounds in select

  20. Application of a high-throughput relative chemical stability assay to screen therapeutic protein formulations by assessment of conformational stability and correlation to aggregation propensity.

    Science.gov (United States)

    Rizzo, Joseph M; Shi, Shuai; Li, Yunsong; Semple, Andrew; Esposito, Jessica J; Yu, Shenjiang; Richardson, Daisy; Antochshuk, Valentyn; Shameem, Mohammed

    2015-05-01

    In this study, an automated high-throughput relative chemical stability (RCS) assay was developed in which various therapeutic proteins were assessed to determine stability based on the resistance to denaturation post introduction to a chaotrope titration. Detection mechanisms of both intrinsic fluorescence and near UV circular dichroism (near-UV CD) are demonstrated. Assay robustness was investigated by comparing multiple independent assays and achieving r(2) values >0.95 for curve overlays. The complete reversibility of the assay was demonstrated by intrinsic fluorescence, near-UV CD, and biologic potency. To highlight the method utility, we compared the RCS assay with differential scanning calorimetry and dynamic scanning fluorimetry methodologies. Utilizing C1/2 values obtained from the RCS assay, formulation rank-ordering of 12 different mAb formulations was performed. The prediction of long-term stability on protein aggregation is obtained by demonstrating a good correlation with an r(2) of 0.83 between RCS and empirical aggregation propensity data. RCS promises to be an extremely useful tool to aid in candidate formulation development efforts based on the complete reversibility of the method to allow for multiple assessments without protein loss and the strong correlation between the C1/2 data obtained and accelerated stability under stressed conditions. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  1. A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels.

    Science.gov (United States)

    Geib, Timon; Meier, Florian; Schorr, Pascal; Lammert, Frank; Stokes, Caroline S; Volmer, Dietrich A

    2015-01-01

    This short application note describes a simple and automated assay for determination of 25-hydroxyvitamin D (25(OH)D) levels in very small volumes of human serum. It utilizes commercial 96-well micro-extraction plates with commercial 25(OH)D isotope calibration and quality control kits. Separation was achieved using a pentafluorophenyl liquid chromatography column followed by multiple reaction monitoring-based quantification on an electrospray triple quadrupole mass spectrometer. Emphasis was placed on providing a simple assay that can be rapidly established in non-specialized laboratories within days, without the need for laborious and time consuming sample preparation steps, advanced calibration or data acquisition routines. The analytical figures of merit obtained from this assay compared well to established assays. To demonstrate the applicability, the assay was applied to analysis of serum samples from patients with chronic liver diseases and compared to results from a routine clinical immunoassay. Copyright © 2015 John Wiley & Sons, Ltd.

  2. A Cancer Cell-Activatable Aptamer-Reporter System for One-Step Assay of Circulating Tumor Cells

    Directory of Open Access Journals (Sweden)

    Zihua Zeng

    2014-01-01

    Full Text Available The current antibody-mediated numeration assays of circulating tumor cells (CTCs require multiple steps and are time-consuming. To overcome these technical limitations, a cancer cell-activatable aptamer-reporter was formulated by conjugating a biomarker-specific aptamer sequence with paired fluorochrome-quencher molecules. In contrast to the antibody probes, the intact aptamer-reporter was optically silent in the absence of cells of interest. However, when used in an assay, the aptamer selectively targeted cancer cells through interaction with a specific surface biomarker, which triggered internalization of the aptamer-reporter and, subsequently, into cell lysosomes. Rapid lysosomal degradation of the aptamer-reporter resulted in separation of the paired fluorochrome-quencher molecules. The released fluorochrome emitted bright fluorescent signals exclusively within the targeted cancer cells, with no background noise in the assay. Thus, the assays could be completed in a single step within minutes. By using this one-step assay, CTCs in whole blood and marrow aspirate samples of patients with lymphoma tumors were selectively highlighted and rapidly detected with no off-target signals from background blood cells. The development of the cancer cell-activatable aptamer-reporter system allows for the possibility of a simple and robust point-of-care test for CTC detection, which is currently unavailable.

  3. Performance of the Xpert HIV-1 Viral Load Assay: a Systematic Review and Meta-analysis.

    Science.gov (United States)

    Nash, Madlen; Huddart, Sophie; Badar, Sayema; Baliga, Shrikala; Saravu, Kavitha; Pai, Madhukar

    2018-04-01

    Viral load (VL) is the preferred treatment-monitoring approach for HIV-positive patients. However, more rapid, near-patient, and low-complexity assays are needed to scale up VL testing. The Xpert HIV-1 VL assay (Cepheid, Sunnyvale, CA) is a new, automated molecular test, and it can leverage the GeneXpert systems that are being used widely for tuberculosis diagnosis. We systematically reviewed the evidence on the performance of this new tool in comparison to established reference standards. A total of 12 articles (13 studies) in which HIV patient VLs were compared between Xpert HIV VL assay and a reference standard VL assay were identified. Study quality was generally high, but substantial variability was observed in the number and type of agreement measures reported. Correlation coefficients between Xpert and reference assays were high, with a pooled Pearson correlation ( n = 8) of 0.94 (95% confidence interval [CI], 0.89, 0.97) and Spearman correlation ( n = 3) of 0.96 (95% CI, 0.86, 0.99). Bland-Altman metrics ( n = 11) all were within 0.35 log copies/ml of perfect agreement. Overall, Xpert HIV-1 VL performed well compared to current reference tests. The minimal training and infrastructure requirements for the Xpert HIV-1 VL assay make it attractive for use in resource-constrained settings, where point-of-care VL testing is most needed. Copyright © 2018 Nash et al.

  4. Differentiating Botulinum Neurotoxin-Producing Clostridia with a Simple, Multiplex PCR Assay.

    Science.gov (United States)

    Williamson, Charles H D; Vazquez, Adam J; Hill, Karen; Smith, Theresa J; Nottingham, Roxanne; Stone, Nathan E; Sobek, Colin J; Cocking, Jill H; Fernández, Rafael A; Caballero, Patricia A; Leiser, Owen P; Keim, Paul; Sahl, Jason W

    2017-09-15

    Diverse members of the genus Clostridium produce botulinum neurotoxins (BoNTs), which cause a flaccid paralysis known as botulism. While multiple species of clostridia produce BoNTs, the majority of human botulism cases have been attributed to Clostridium botulinum groups I and II. Recent comparative genomic studies have demonstrated the genomic diversity within these BoNT-producing species. This report introduces a multiplex PCR assay for differentiating members of C. botulinum group I, C. sporogenes , and two major subgroups within C. botulinum group II. Coding region sequences unique to each of the four species/subgroups were identified by in silico analyses of thousands of genome assemblies, and PCR primers were designed to amplify each marker. The resulting multiplex PCR assay correctly assigned 41 tested isolates to the appropriate species or subgroup. A separate PCR assay to determine the presence of the ntnh gene (a gene associated with the botulinum neurotoxin gene cluster) was developed and validated. The ntnh gene PCR assay provides information about the presence or absence of the botulinum neurotoxin gene cluster and the type of gene cluster present ( ha positive [ ha + ] or orfX + ). The increased availability of whole-genome sequence data and comparative genomic tools enabled the design of these assays, which provide valuable information for characterizing BoNT-producing clostridia. The PCR assays are rapid, inexpensive tests that can be applied to a variety of sample types to assign isolates to species/subgroups and to detect clostridia with botulinum neurotoxin gene ( bont ) clusters. IMPORTANCE Diverse clostridia produce the botulinum neurotoxin, one of the most potent known neurotoxins. In this study, a multiplex PCR assay was developed to differentiate clostridia that are most commonly isolated in connection with human botulism cases: C. botulinum group I, C. sporogenes , and two major subgroups within C. botulinum group II. Since Bo

  5. Performance evaluation of FlowCytomix assays to quantify cytokines in patients with rheumatoid arthritis

    Science.gov (United States)

    Wang, Xuefeng; Dong, Liyang; Liang, Yong; Ni, Hongchang; Tang, Jun; Xu, Chengcheng; Zhou, Yuepeng; Su, Yuting; Wang, Jun; Chen, Deyu; Mao, Chaoming

    2015-01-01

    Objectives: To compare the cytokine profile in RA patients and healthy control by using two methods-FlowCytomix assay and traditional ELISA. Methods: Cytokine levels were evaluated by FlowCytomix assay and ELISA in serum and supernatants of peripheral blood mononuclear cells (PBMC) cultures with and without stimulation by phytohaemagglutinin (PHA). Results: The levels of IL-6, IL-1β, and TNF-α were significantly higher in sera of RA patients than those of healthy controls. The levels of IL-22, IL-6, IL-1β, TNF-α, and IL-10 were higher in unstimulated PBMC culture supernatant of RA patients than those of healthy controls. PHA stimulation significantly increased the production of proinflammatory cytokines from PBMC with RA patients. Compared with detectable cytokine levels in sera, cytokine concentration in the supernatant of PBMCs was remarkably higher. FlowCytomix and ELISA showed significant correlation in detecting cytokines. However, the FlowCytomix assay detected more cytokines than ELISA. Conclusion: The supernatant of PBMCs provide a fine condition for the study of cytokine production because of the lack of interference factors in sera. The FlowCytomix assay is more sensitive than ELISA in detecting cytokines from RA patients. Multiple cytokine signatures using FlowCytomix assay may represent a more realistic approach in the future of personalized medicine in RA. PMID:26629129

  6. How to induce multiple delays in coupled chaotic oscillators?

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmick, Sourav K. [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India); Department of Electronics, Asutosh College, Kolkata 700026 (India); Ghosh, Dibakar [Physics and Applied Mathematics Unit, Indian Statistical Institute, Kolkata 700108 (India); Roy, Prodyot K. [Department of Physics, Presidency University, Kolkata 700073 (India); Kurths, Jürgen [Potsdam Institute for Climate Impact Research, 14473 Potsdam (Germany); Institute for Physics, Humboldt University, 12489 Berlin (Germany); Dana, Syamal K. [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India)

    2013-12-15

    Lag synchronization is a basic phenomenon in mismatched coupled systems, delay coupled systems, and time-delayed systems. It is characterized by a lag configuration that identifies a unique time shift between all pairs of similar state variables of the coupled systems. In this report, an attempt is made how to induce multiple lag configurations in coupled systems when different pairs of state variables attain different time shift. A design of coupling is presented to realize this multiple lag synchronization. Numerical illustration is given using examples of the Rössler system and the slow-fast Hindmarsh-Rose neuron model. The multiple lag scenario is physically realized in an electronic circuit of two Sprott systems.

  7. Clinical Trials With Large Numbers of Variables: Important Advantages of Canonical Analysis.

    Science.gov (United States)

    Cleophas, Ton J

    2016-01-01

    Canonical analysis assesses the combined effects of a set of predictor variables on a set of outcome variables, but it is little used in clinical trials despite the omnipresence of multiple variables. The aim of this study was to assess the performance of canonical analysis as compared with traditional multivariate methods using multivariate analysis of covariance (MANCOVA). As an example, a simulated data file with 12 gene expression levels and 4 drug efficacy scores was used. The correlation coefficient between the 12 predictor and 4 outcome variables was 0.87 (P = 0.0001) meaning that 76% of the variability in the outcome variables was explained by the 12 covariates. Repeated testing after the removal of 5 unimportant predictor and 1 outcome variable produced virtually the same overall result. The MANCOVA identified identical unimportant variables, but it was unable to provide overall statistics. (1) Canonical analysis is remarkable, because it can handle many more variables than traditional multivariate methods such as MANCOVA can. (2) At the same time, it accounts for the relative importance of the separate variables, their interactions and differences in units. (3) Canonical analysis provides overall statistics of the effects of sets of variables, whereas traditional multivariate methods only provide the statistics of the separate variables. (4) Unlike other methods for combining the effects of multiple variables such as factor analysis/partial least squares, canonical analysis is scientifically entirely rigorous. (5) Limitations include that it is less flexible than factor analysis/partial least squares, because only 2 sets of variables are used and because multiple solutions instead of one is offered. We do hope that this article will stimulate clinical investigators to start using this remarkable method.

  8. Measuring behaviours for escaping from house fires: use of latent variable models to summarise multiple behaviours.

    Science.gov (United States)

    Ploubidis, G B; Edwards, P; Kendrick, D

    2015-12-15

    This paper reports the development and testing of a construct measuring parental fire safety behaviours for planning escape from a house fire. Latent variable modelling of data on parental-reported fire safety behaviours and plans for escaping from a house fire and multivariable logistic regression to quantify the association between groups defined by the latent variable modelling and parental-report of having a plan for escaping from a house fire. Data comes from 1112 participants in a cluster randomised controlled trial set in children's centres in 4 study centres in the UK. A two class model provided the best fit to the data, combining responses to five fire safety planning behaviours. The first group ('more behaviours for escaping from a house fire') comprised 86% of participants who were most likely to have a torch, be aware of how their smoke alarm sounds, to have external door and window keys accessible, and exits clear. The second group ('fewer behaviours for escaping from a house fire') comprised 14% of participants who were less likely to report these five behaviours. After adjusting for potential confounders, participants allocated to the 'more behaviours for escaping from a house fire group were 2.5 times more likely to report having an escape plan (OR 2.48; 95% CI 1.59-3.86) than those in the "fewer behaviours for escaping from a house fire" group. Multiple fire safety behaviour questions can be combined into a single binary summary measure of fire safety behaviours for escaping from a house fire. Our findings will be useful to future studies wishing to use a single measure of fire safety planning behaviour as measures of outcome or exposure. NCT 01452191. Date of registration 13/10/2011.

  9. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  10. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  11. A versatile electrowetting-based digital microfluidic platform for quantitative homogeneous and heterogeneous bio-assays

    Science.gov (United States)

    Vergauwe, Nicolas; Witters, Daan; Ceyssens, Frederik; Vermeir, Steven; Verbruggen, Bert; Puers, Robert; Lammertyn, Jeroen

    2011-05-01

    Electrowetting-on-dielectric (EWOD) lab-on-a-chip systems have already proven their potential within a broad range of bio-assays. Nevertheless, research on the analytical performance of those systems is limited, yet crucial for a further breakthrough in the diagnostic field. Therefore, this paper presents the intrinsic possibilities of an EWOD lab-on-a-chip as a versatile platform for homogeneous and heterogeneous bio-assays with high analytical performance. Both droplet dispensing and splitting cause variations in droplet size, thereby directly influencing the assay's performance. The extent to which they influence the performance is assessed by a theoretical sensitivity analysis, which allows the definition of a basic framework for the reduction of droplet size variability. Taking advantage of the optimized droplet manipulations, both homogeneous and heterogeneous bio-assays are implemented in the EWOD lab-on-a-chip to demonstrate the analytical capabilities and versatility of the device. A fully on-chip enzymatic assay is realized with high analytical performance. It demonstrates the promising capabilities of an EWOD lab-on-a-chip in food-related and medical applications, such as nutritional and blood analyses. Further, a magnetic bio-assay for IgE detection using superparamagnetic nanoparticles is presented whereby the nanoparticles are used as solid carriers during the bio-assay. Crucial elements are the precise manipulation of the superparamagnetic nanoparticles with respect to dispensing and separation. Although the principle of using nano-carriers is demonstrated for protein detection, it can be easily extended to a broader range of bio-related applications like DNA sensing. In heterogeneous bio-assays the chip surface is actively involved during the execution of the bio-assay. Through immobilization of specific biological compounds like DNA, proteins and cells a reactive chip surface is realized, which enhances the bio-assay performance. To demonstrate

  12. Development of a Rapid Real-Time PCR Assay for Quantitation of Pneumocystis carinii f. sp. Carinii

    DEFF Research Database (Denmark)

    Larsen, Hans Henrik; Kovacs, Joseph A; Stock, Frida

    2002-01-01

    6 log values for standards containing > or =5 copies/tube. Application of the assay to a series of 10-fold dilutions of P. carinii organisms isolated from rat lung demonstrated that it was reproducibly quantitative over 5 log values (r = 0.99). The assay was applied to a recently reported in vitro...... axenic cultivation system for P. carinii and confirmed our microscopy findings that no organism multiplication had occurred during culture. For all cultures analyzed, QTD PCR assays showed a decrease in P. carinii DNA that exceeded the expected decrease due to dilution of the inoculum upon transfer......A method for reliable quantification of Pneumocystis carinii in research models of P. carinii pneumonia (PCP) that is more convenient and reproducible than microscopic enumeration of organisms would greatly facilitate investigations of this organism. We developed a rapid quantitative touchdown (QTD...

  13. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  14. Radiometric assays for the measurement of PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.

    1997-01-01

    Prostate Specific Antigen, a serine protease enzyme, of M.W. ∼ 26-33 kDa, is widely considered to be a very useful marker for prostate cancer. It satisfies nearly all the requirements of an ideal 'Tumour Marker' and has hence attracted a lot of attention in the past decade. PSA is present in multiple forms in serum, with an appreciable fraction bound to the protease inhibitor α-1-antichymotrypsin (ACT) and to a small extent to other proteins such as α-2-macroglobulin (AMG) leaving the rest in the free form. The total PSA levels have been reported to have 80% sensitivity and 60% specificity towards the detection of prostate cancer. The lack of specificity occurs mainly due to the high levels of t-PSA in benign prostatic hypertrophy(BPH) apart from the cancer. The concept of free PSA has been introduced in the recent past and the ratio of free/total PSA levels have been shown to be advantageous in the differential diagnosis of BPH from prostate cancer. The f/t ratio is considered to be particularly useful in the grey zones of decision making (t-PSA levels 4-20 ng/mL). The need for the development of assays for total and free PSA is felt due to: a. the high incidence of prostate cancers being detected currently; b. the high cost of tests (higher for free PSA assay, and the cost becomes an important parameter when a patient has to be regularly monitored after therapy) that is not affordable for many patients; c. the potential for research in the area of prostate cancer management where the PSA (total and free) assays will be of great help

  15. Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta

    DEFF Research Database (Denmark)

    Hermanrud, Christina; Ryner, Malin; Luft, Thomas

    2016-01-01

    a normal distribution for the majority of runs, allowing a parametric approach for cut-point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays......Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFNβ) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach...... to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines...

  16. RAWS II: A MULTIPLE REGRESSION ANALYSIS PROGRAM,

    Science.gov (United States)

    This memorandum gives instructions for the use and operation of a revised version of RAWS, a multiple regression analysis program. The program...of preprocessed data, the directed retention of variable, listing of the matrix of the normal equations and its inverse, and the bypassing of the regression analysis to provide the input variable statistics only. (Author)

  17. Comparison of the performance in detection of HPV infections between the high-risk HPV genotyping real time PCR and the PCR-reverse dot blot assays.

    Science.gov (United States)

    Zhang, Lahong; Dai, Yibei; Chen, Jiahuan; Hong, Liquan; Liu, Yuhua; Ke, Qiang; Chen, Yiwen; Cai, Chengsong; Liu, Xia; Chen, Zhaojun

    2018-01-01

    A new multiplex real-time PCR assay, the high-risk HPV genotyping real time PCR assay (HR HPV RT-PCR), has been developed to detect 15 high-risk HPV types with respective viral loads. In this report, a total of 684 cervical specimens from women diagnosed with vaginitis were assessed by the HR HPV RT-PCR and the PCR reaction and reverse dot blot (PCR-RDB) assays, using a PCR-sequencing method as a reference standard. A total coincidence of 97.7% between the HR HPV RT PCR and the PCR-RDB assays was determined with a Kappa value of 0.953. The HR HPV RT PCR assay had sensitivity, specificity, and concordance rates (accuracy) of 99.7%, 99.7%, and 99.7%, respectively, as confirmed by PCR-sequencing, while the PCR-RDB assay had respective rates of 98.8%, 97.1%, and 98.0%. The overall rate of HPV infection, determined by PCR-sequencing, in women diagnosed with vaginitis was 49.85%, including 36.26% of single infection and 13.6% of multiple infections. The most common infections among the 15 high-risk HPV types in women diagnosed with vaginitis were HPV-52, HPV-16, and HPV-58, with a total detection rate of 10.23%, 7.75%, and 5.85%, respectively. We conclude that the HR HPV RT PCR assay exhibits better clinical performance than the PCR-RDB assay, and is an ideal alternative method for HPV genotyping. In addition, the HR HPV RT PCR assay provides HPV DNA viral loads, and could serve as a quantitative marker in the diagnosis and treatment of single and multiple HPV infections. © 2017 Wiley Periodicals, Inc.

  18. Simultaneous Two-Way Clustering of Multiple Correspondence Analysis

    Science.gov (United States)

    Hwang, Heungsun; Dillon, William R.

    2010-01-01

    A 2-way clustering approach to multiple correspondence analysis is proposed to account for cluster-level heterogeneity of both respondents and variable categories in multivariate categorical data. Specifically, in the proposed method, multiple correspondence analysis is combined with k-means in a unified framework in which "k"-means is…

  19. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    International Nuclear Information System (INIS)

    Liu, Yaou; Duan, Yunyun; He, Yong; Yu, Chunshui; Wang, Jun; Huang, Jing; Ye, Jing; Parizel, Paul M.; Li, Kuncheng; Shu, Ni

    2012-01-01

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS

  20. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yaou, E-mail: asiaeurope80@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Duan, Yunyun, E-mail: xiaoyun81.love@163.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); He, Yong, E-mail: yong.h.he@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Yu, Chunshui, E-mail: csyuster@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Wang, Jun, E-mail: jun_wang@bnu.edu.cn [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Huang, Jing, E-mail: sainthj@126.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Ye, Jing, E-mail: jingye.2007@yahoo.com.cn [Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Parizel, Paul M., E-mail: paul.parizel@ua.ac.be [Department of Radiology, Antwerp University Hospital and University of Antwerp, Wilrijkstraat 10, 2650 Edegem, 8 Belgium (Belgium); Li, Kuncheng, E-mail: kunchengli55@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Shu, Ni, E-mail: nshu55@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China)

    2012-10-15

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS.

  1. Overview of procalcitonin assays and procalcitonin-guided protocols for the management of patients with infections and sepsis.

    Science.gov (United States)

    Schuetz, Philipp; Bretscher, Celine; Bernasconi, Luca; Mueller, Beat

    2017-06-01

    Procalcitonin is a surrogate infection blood marker whose levels help estimate the likelihood of bacterial infections and correlate with their resolution. Recent trials have revealed the benefits of inclusion of procalcitonin in antibiotic stewardship protocols for initiation and discontinuation of antimicrobial therapy. Areas covered: Procalcitonin-guided antibiotic stewardship protocols have shown appreciable reductions in antibiotic use and duration of therapy in respiratory infections, sepsis, and other infections, with positive effects on clinical outcomes. Multiple fully automated and sensitive procalcitonin assays are routinely used in clinical practice. Utilization of these assays requires consideration of the clinical setting and knowledge of assay characteristics, particularly assay sensitivities, reproducibility, and performance across routinely used cut-off ranges. The authors provide an overview of the strengths and limitations of currently available procalcitonin assays and antibiotic therapy algorithms incorporating procalcitonin currently used in different clinical settings and in patients with different underlying infections. Expert commentary: Use of sensitive procalcitonin measurements in clinical algorithms can reduce antimicrobial overuse, decreasing the risk of side effects and controlling emerging bacterial multi-resistance. Before use in clinical practice, it is important to carefully assess the quality of novel PCT assays and rigorously evaluate them in target patient populations across clinically relevant cut-off ranges.

  2. THE CHANDRA VARIABLE GUIDE STAR CATALOG

    International Nuclear Information System (INIS)

    Nichols, Joy S.; Lauer, Jennifer L.; Morgan, Douglas L.; Sundheim, Beth A.; Henden, Arne A.; Huenemoerder, David P.; Martin, Eric

    2010-01-01

    Variable stars have been identified among the optical-wavelength light curves of guide stars used for pointing control of the Chandra X-ray Observatory. We present a catalog of these variable stars along with their light curves and ancillary data. Variability was detected to a lower limit of 0.02 mag amplitude in the 4000-10000 A range using the photometrically stable Aspect Camera on board the Chandra spacecraft. The Chandra Variable Guide Star Catalog (VGUIDE) contains 827 stars, of which 586 are classified as definitely variable and 241 are identified as possibly variable. Of the 586 definite variable stars, we believe 319 are new variable star identifications. Types of variables in the catalog include eclipsing binaries, pulsating stars, and rotating stars. The variability was detected during the course of normal verification of each Chandra pointing and results from analysis of over 75,000 guide star light curves from the Chandra mission. The VGUIDE catalog represents data from only about 9 years of the Chandra mission. Future releases of VGUIDE will include newly identified variable guide stars as the mission proceeds. An important advantage of the use of space data to identify and analyze variable stars is the relatively long observations that are available. The Chandra orbit allows for observations up to 2 days in length. Also, guide stars were often used multiple times for Chandra observations, so many of the stars in the VGUIDE catalog have multiple light curves available from various times in the mission. The catalog is presented as both online data associated with this paper and as a public Web interface. Light curves with data at the instrumental time resolution of about 2 s, overplotted with the data binned at 1 ks, can be viewed on the public Web interface and downloaded for further analysis. VGUIDE is a unique project using data collected during the mission that would otherwise be ignored. The stars available for use as Chandra guide stars are

  3. Application of the dose conversion factor for a NaI(Tl) detector to the radwaste drum assay

    International Nuclear Information System (INIS)

    Ji, Young-Yong; Hong, Dae-Seok; Kim, Tae-Kuk; Kwak, Kyung-Kil; Ryu, Woo-Seog

    2011-01-01

    The dose-to-curie (DTC) conversion method has been known that there could be extremely high uncertainty associated with establishing the radioactivity of gamma emitters in a drum. However, the DTC conversion method is still an effective assay method to calculate the radioisotope inventory because of the simple and easy procedures to be applied. In order to make the DTC conversion method practical, numerous assumptions and limitations placed on its use. These assumptions and limitations are related to the dose rate measurement and the relative abundance of gamma emitters in a drum. However, these two variables were generally obtained from the different detection mechanisms even using the different radwaste each other. Unfortunately, that expanded the limitation of using the DTC conversion method. In order to obtain two variables in a drum to be assayed at once, the dose conversion factor for a NaI(Tl) detector was first calculated from the MCNP code. The pulse height spectrum from a simulated drum inserted into a standard source was measured by a NaI(Tl) detector, and then, two variables were calculated from the dose conversion factor and the net count rate of detected gamma emitters in the pulse height spectrum.

  4. Combined high-performance liquid chromatography/32P-postlabeling assay of N7-methyldeoxyguanosine

    International Nuclear Information System (INIS)

    Shields, P.G.; Povey, A.C.; Wilson, V.L.; Weston, A.; Harris, C.C.

    1990-01-01

    A highly sensitive and specific assay for the detection of N7-methyl-2'-deoxyguanosine (N7methyldG) has been developed by combining high-performance liquid chromatography, 32 P-postlabeling, and nucleotide chromatography. Separation of normal nucleotides and adducts by high-performance liquid chromatography and then combining a portion of 2'-deoxyguanosine to the N7methyldG allows for quantitation using an internal standard. The directly determined molar ratio is not subject to errors in digestion, variable ATP-specific activity, or assumptions in relative adduct-labeling efficiency. The detection limit was one N7methyldG adduct in 10(7) unmodified 2'-deoxyguanosine bases. N7methyldG adducts have been detected in 5 human lung samples in which O6-methyl-2'-deoxyguanosine adducts had been previously determined. The mean ratio of N7methyldG to O6-methyl-2'-deoxyguanosine was determined to be approximately 10. The current assay complements the high-performance liquid chromatography/ 32 P-postlabeling assay for O6-methyl-2'-deoxyguanosine and increases the detection sensitivity of DNA methylated by exogenous alkylating agents

  5. Analysis of streamflow variability in Alpine catchments at multiple spatial and temporal scales

    Science.gov (United States)

    Pérez Ciria, T.; Chiogna, G.

    2017-12-01

    Alpine watersheds play a pivotal role in Europe for water provisioning and for hydropower production. In these catchments, temporal fluctuations of river discharge occur at multiple temporal scales due to natural as well as anthropogenic driving forces. In the last decades, modifications of the flow regime have been observed and their origin lies in the complex interplay between construction of dams for hydro power production, changes in water management policies and climatic changes. The alteration of the natural flow has negative impacts on the freshwater biodiversity and threatens the ecosystem integrity of the Alpine region. Therefore, understanding the temporal and spatial variability of river discharge has recently become a particular concern for environmental protection and represents a crucial contribution to achieve sustainable water resources management in the Alps. In this work, time series analysis is conducted for selected gauging stations in the Inn and the Adige catchments, which cover a large part of the central and eastern region of the Alps. We analyze the available time series using the continuous wavelet transform and change-point analyses for determining how and where changes have taken place. Although both catchments belong to different climatic zones of the Greater Alpine Region, streamflow properties share some similar characteristics. The comparison of the collected streamflow time series in the two catchments permits detecting gradients in the hydrological system dynamics that depend on station elevation, longitudinal location in the Alps and catchment area. This work evidences that human activities (e.g., water management practices and flood protection measures, changes in legislation and market regulation) have major impacts on streamflow and should be rigorously considered in hydrological models.

  6. Spatial and Temporal Variability in Biogenic Gas Accumulation and Release in The Greater Everglades at Multiple Scales of Measurement

    Science.gov (United States)

    McClellan, M. D.; Cornett, C.; Schaffer, L.; Comas, X.

    2017-12-01

    Wetlands play a critical role in the carbon (C) cycle by producing and releasing significant amounts of greenhouse biogenic gasses (CO2, CH4) into the atmosphere. Wetlands in tropical and subtropical climates (such as the Florida Everglades) have become of great interest in the past two decades as they account for more than 20% of the global peatland C stock and are located in climates that favor year-round C emissions. Despite the increase in research involving C emission from these types of wetlands, the spatial and temporal variability involving C production, accumulation and release is still highly uncertain, and is the focus of this research at multiple scales of measurement (i.e. lab, field and landscape). Spatial variability in biogenic gas content, build up and release, at both the lab and field scales, was estimated using a series of ground penetrating radar (GPR) surveys constrained with gas traps fitted with time-lapse cameras. Variability in gas content was estimated at the sub-meter scale (lab scale) within two extracted monoliths from different wetland ecosystems at the Disney wilderness Preserve (DWP) and the Blue Cypress Preserve (BCP) using high frequency GPR (1.2 GHz) transects across the monoliths. At the field scale (> 10m) changes in biogenic gas content were estimated using 160 MHz GPR surveys collected within 4 different emergent wetlands at the DWP. Additionally, biogenic gas content from the extracted monoliths was used to developed a landscape comparison of C accumulation and emissions for each different wetland ecosystem. Changes in gas content over time were estimated at the lab scale at high temporal resolution (i.e. sub-hourly) in monoliths from the BCP and Water Conservation Area 1-A. An autonomous rail system was constructed to estimate biogenic gas content variability within the wetland soil matrix using a series of continuous, uninterrupted 1.2 GHz GPR transects along the samples. Measurements were again constrained with an array

  7. Multiple Response Regression for Gaussian Mixture Models with Known Labels.

    Science.gov (United States)

    Lee, Wonyul; Du, Ying; Sun, Wei; Hayes, D Neil; Liu, Yufeng

    2012-12-01

    Multiple response regression is a useful regression technique to model multiple response variables using the same set of predictor variables. Most existing methods for multiple response regression are designed for modeling homogeneous data. In many applications, however, one may have heterogeneous data where the samples are divided into multiple groups. Our motivating example is a cancer dataset where the samples belong to multiple cancer subtypes. In this paper, we consider modeling the data coming from a mixture of several Gaussian distributions with known group labels. A naive approach is to split the data into several groups according to the labels and model each group separately. Although it is simple, this approach ignores potential common structures across different groups. We propose new penalized methods to model all groups jointly in which the common and unique structures can be identified. The proposed methods estimate the regression coefficient matrix, as well as the conditional inverse covariance matrix of response variables. Asymptotic properties of the proposed methods are explored. Through numerical examples, we demonstrate that both estimation and prediction can be improved by modeling all groups jointly using the proposed methods. An application to a glioblastoma cancer dataset reveals some interesting common and unique gene relationships across different cancer subtypes.

  8. Changes of Motivational Variables in Patients with Multiple Sclerosis in an Exercise Intervention: Associations between Physical Performance and Motivational Determinants

    Directory of Open Access Journals (Sweden)

    Wiebke Geertz

    2015-01-01

    Full Text Available Objectives. This study examines the effects of a standardized fitness training on motivational factors such as the intention to be physically active, self-efficacy, perceived barriers, counterstrategies, and exercise specific social support in patients with progressive Multiple Sclerosis (MS and the relation of these factors to physical performance. Methods. Moderately disabled patients with secondary or primary progressive MS (Expanded Disability Status Scale of 4–6 were randomized to a training group or a waitlist control group. Patients completed on average 20 sessions of training tailored to their individual fitness at baseline over a course of 8–12 weeks. Motivational variables (stage of change according to the transtheoretical model (TTM, self-efficacy, perceived barriers, counterstrategies, and exercise specific social support were assessed via questionnaires at baseline and follow-up. Results. Forty patients completed the trial. We found significant effects on stages of change p=.016 and self-efficacy p=.014 and a trend in counterstrategies p=.08. Significant correlations between change of physical performance during the exercise training and change in the TTM, perceived barriers, and counterstrategies were detected. Conclusion. This study indicates that tailored individual endurance training could stabilize self-efficacy and increase exercise motivation in patients with progressive MS. Motivational variables were related to the physical performance.

  9. Multiple Off-Ice Performance Variables Predict On-Ice Skating Performance in Male and Female Division III Ice Hockey Players

    Directory of Open Access Journals (Sweden)

    effrey M. Janot, Nicholas M. Beltz, Lance D. Dalleck

    2015-09-01

    Full Text Available The purpose of this study was to determine if off-ice performance variables could predict on-ice skating performance in Division III collegiate hockey players. Both men (n = 15 and women (n = 11 hockey players (age = 20.5 ± 1.4 years participated in the study. The skating tests were agility cornering S-turn, 6.10 m acceleration, 44.80 m speed, modified repeat skate, and 15.20 m full speed. Off-ice variables assessed were years of playing experience, height, weight and percent body fat and off-ice performance variables included vertical jump (VJ, 40-yd dash (36.58m, 1-RM squat, pro-agility, Wingate peak power and peak power percentage drop (% drop, and 1.5 mile (2.4km run. Results indicated that 40-yd dash (36.58m, VJ, 1.5 mile (2.4km run, and % drop were significant predictors of skating performance for repeat skate (slowest, fastest, and average time and 44.80 m speed time, respectively. Four predictive equations were derived from multiple regression analyses: 1 slowest repeat skate time = 2.362 + (1.68 x 40-yd dash time + (0.005 x 1.5 mile run, 2 fastest repeat skate time = 9.762 - (0.089 x VJ - (0.998 x 40-yd dash time, 3 average repeat skate time = 7.770 + (1.041 x 40-yd dash time - (0.63 x VJ + (0.003 x 1.5 mile time, and 4 47.85 m speed test = 7.707 - (0.050 x VJ - (0.01 x % drop. It was concluded that selected off-ice tests could be used to predict on-ice performance regarding speed and recovery ability in Division III male and female hockey players.

  10. A Bayesian Hierarchical Model for Relating Multiple SNPs within Multiple Genes to Disease Risk

    Directory of Open Access Journals (Sweden)

    Lewei Duan

    2013-01-01

    Full Text Available A variety of methods have been proposed for studying the association of multiple genes thought to be involved in a common pathway for a particular disease. Here, we present an extension of a Bayesian hierarchical modeling strategy that allows for multiple SNPs within each gene, with external prior information at either the SNP or gene level. The model involves variable selection at the SNP level through latent indicator variables and Bayesian shrinkage at the gene level towards a prior mean vector and covariance matrix that depend on external information. The entire model is fitted using Markov chain Monte Carlo methods. Simulation studies show that the approach is capable of recovering many of the truly causal SNPs and genes, depending upon their frequency and size of their effects. The method is applied to data on 504 SNPs in 38 candidate genes involved in DNA damage response in the WECARE study of second breast cancers in relation to radiotherapy exposure.

  11. Biological variability of glycated hemoglobin.

    Science.gov (United States)

    Braga, Federica; Dolci, Alberto; Mosca, Andrea; Panteghini, Mauro

    2010-11-11

    The measurement of glycated hemoglobin (HbA(1c)) has a pivotal role in monitoring glycemic state in diabetic patients. Furthermore, the American Diabetes Association has recently recommended the use of HbA(1c) for diabetes diagnosis, but a clear definition of the clinically allowable measurement error is still lacking. Information on biological variability of the analyte can be used to achieve this goal. We systematically reviewed the published studies on the biological variation of HbA(1c) to check consistency of available data in order to accurately define analytical goals. The nine recruited studies were limited by choice of analytic methodology, population selection, protocol application and statistical analyses. There is an urgent need to determine biological variability of HbA(1c) using a specific and traceable assay, appropriate protocol and appropriate statistical evaluation of data. 2010 Elsevier B.V. All rights reserved.

  12. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  13. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  14. Interobserver variability and feasibility of polymerase chain reaction-based assay in distinguishing ischemic colitis from Clostridium difficile colitis in endoscopic mucosal biopsies.

    Science.gov (United States)

    Wiland, Homer O; Procop, Gary W; Goldblum, John R; Tuohy, Marion; Rybicki, Lisa; Patil, Deepa T

    2013-06-01

    Polymerase chain reaction (PCR)-based assays using stool samples are currently the most effective method of detecting Clostridium difficile. This study examines the feasibility of this assay using mucosal biopsy samples and evaluates the interobserver reproducibility in diagnosing and distinguishing ischemic colitis from C difficile colitis. Thirty-eight biopsy specimens were reviewed and classified by 3 observers into C difficile and ischemic colitis. The findings were correlated with clinical data. PCR was performed on 34 cases using BD GeneOhm C difficile assay. The histologic interobserver agreement was excellent (κ= 0.86) and the agreement between histologic and clinical diagnosis was good (κ = 0.84). All 19 ischemic colitis cases tested negative (100% specificity) and 3 of 15 cases of C difficile colitis tested positive (20% sensitivity). C difficile colitis can be reliably distinguished from ischemic colitis using histologic criteria. The C difficile PCR test on endoscopic biopsy specimens has excellent specificity but limited sensitivity.

  15. Development And Application of Functional Assays For Freshwater Dissolved Organic Matter

    Science.gov (United States)

    Thacker, S.; Tipping, E.; Gondar, D.; Baker, A.

    2006-12-01

    Dissolved organic matter (DOM) in natural waters participates in many important ecological and geochemical reactions, including acid-base buffering, light absorption, proton binding, binding of heavy metals, organic contaminants, aluminium and radionuclides, adsorption at surfaces, aggregation and photochemical reactivity. We are studying DOM in order to understand and quantify these functional properties, so we can use the knowledge to predict the influence of DOM on the natural freshwater environment. As DOM has no readily identifiable structure, our approach is to measure what it does, rather than what it is. Thus, we have developed a series of 12 standardised, reproducible assays of physico-chemical functions of dissolved organic matter (DOM) in freshwaters. The assays provide quantitative information on light absorption, fluorescence, photochemical fading, pH buffering, copper binding, benzo(a)pyrene binding, hydrophilicity and adsorption to alumina. We have collected twenty DOM samples in total, ten samples from a eutrophic lake (Esthwaite Water) and ten samples from three stream waters. A mild isolation method was then used to concentrate the DOM samples for the assay work. When assaying the concentrates, parallel assays were also preformed with Suwannee River Fulvic Acid (SRFA), as a quality control standard. Our results showed that; (i) for eleven of the assays, the variability among the twenty DOM samples was significantly (p<0.001) greater than can be explained by analytical error, i.e. by comparison with results from the SRFA quality control; (ii) the functional properties of the DOM from Esthwaite Water are strongly influenced by the seasonally-dependent input of autochthonous DOM, derived from phytoplankton. The autochthonous DOM is less fluorescent, light absorbing, hydrophobic and has a lower acid group content and capacity to be adsorbed onto alumina than terrestrially derived allochthonous DOM; (iii) significant correlations were found between

  16. Validation of a next-generation sequencing assay for clinical molecular oncology.

    Science.gov (United States)

    Cottrell, Catherine E; Al-Kateb, Hussam; Bredemeyer, Andrew J; Duncavage, Eric J; Spencer, David H; Abel, Haley J; Lockwood, Christina M; Hagemann, Ian S; O'Guin, Stephanie M; Burcea, Lauren C; Sawyer, Christopher S; Oschwald, Dayna M; Stratman, Jennifer L; Sher, Dorie A; Johnson, Mark R; Brown, Justin T; Cliften, Paul F; George, Bijoy; McIntosh, Leslie D; Shrivastava, Savita; Nguyen, Tudung T; Payton, Jacqueline E; Watson, Mark A; Crosby, Seth D; Head, Richard D; Mitra, Robi D; Nagarajan, Rakesh; Kulkarni, Shashikant; Seibert, Karen; Virgin, Herbert W; Milbrandt, Jeffrey; Pfeifer, John D

    2014-01-01

    Currently, oncology testing includes molecular studies and cytogenetic analysis to detect genetic aberrations of clinical significance. Next-generation sequencing (NGS) allows rapid analysis of multiple genes for clinically actionable somatic variants. The WUCaMP assay uses targeted capture for NGS analysis of 25 cancer-associated genes to detect mutations at actionable loci. We present clinical validation of the assay and a detailed framework for design and validation of similar clinical assays. Deep sequencing of 78 tumor specimens (≥ 1000× average unique coverage across the capture region) achieved high sensitivity for detecting somatic variants at low allele fraction (AF). Validation revealed sensitivities and specificities of 100% for detection of single-nucleotide variants (SNVs) within coding regions, compared with SNP array sequence data (95% CI = 83.4-100.0 for sensitivity and 94.2-100.0 for specificity) or whole-genome sequencing (95% CI = 89.1-100.0 for sensitivity and 99.9-100.0 for specificity) of HapMap samples. Sensitivity for detecting variants at an observed 10% AF was 100% (95% CI = 93.2-100.0) in HapMap mixes. Analysis of 15 masked specimens harboring clinically reported variants yielded concordant calls for 13/13 variants at AF of ≥ 15%. The WUCaMP assay is a robust and sensitive method to detect somatic variants of clinical significance in molecular oncology laboratories, with reduced time and cost of genetic analysis allowing for strategic patient management. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  17. Development and Validation of a Multiplex PCR-Based Assay for the Upper Respiratory Tract Bacterial Pathogens Haemophilus influenzae, Streptococcus pneumoniae, and Moraxella catarrhalis.

    Science.gov (United States)

    Post; White; Aul; Zavoral; Wadowsky; Zhang; Preston; Ehrlich

    1996-06-01

    Background: Conventional simplex polymerase chain reaction (PCR)-based assays are limited in that they only provide for the detection of a single infectious agent. Many clinical diseases, however, present in a nonspecific, or syndromic, fashion, thereby necessitating the simultaneous assessment of multiple pathogens. Panel-based molecular diagnostic testing can be accomplished by the development of multiplex PCR-based assays, which can detect, individually or severally, different pathogens that are associated with syndromic illness. As part of a larger program of panel development, an assay that can simultaneously detect Haemophilus influenzae, Streptococcus pneumoniae, and Moraxella catarrhalis was developed. These organisms were chosen as they are the most common bacterial pathogens associated with both the acute and chronic forms of otitis media; they are also responsible for a high percentage of sinus infections in both children and adults. In addition, H. influenzae and S. pneumoniae are commonly associated with septic meningitits. Methods and Results: Multiple individual PCR-based assays were developed for each of the three target organisms which were then evaluated for sensitivity and specificity. Utilizing the simplex assays that met our designated performance criteria, a matrix style approach was used to develop a duplex H. influenzae-S. pneumoniae assay. The duplex assay was then used as a single component in the development of a triplex assay, wherein the various M. catarrhalis primer-probe sets were tested for compatibility with the existing assay. A single-step PCR protocol, with species-specific primers for each of the three target organisms and a liquid hybridization-gel retardation amplimer detection system, was developed, which amplifies and then discriminates among each of the amplification products according to size. This assay is able to detect all three organisms in a specific manner, either individually or severally. Dilutional experiments

  18. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  19. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    Science.gov (United States)

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  20. Phenotypic assays for Mycobacterium tuberculosis infection.

    Science.gov (United States)

    Song, Ok-Ryul; Deboosere, Nathalie; Delorme, Vincent; Queval, Christophe J; Deloison, Gaspard; Werkmeister, Elisabeth; Lafont, Frank; Baulard, Alain; Iantomasi, Raffaella; Brodin, Priscille

    2017-10-01

    Tuberculosis (TB) is still a major global threat, killing more than one million persons each year. With the constant increase of Mycobacterium tuberculosis strains resistant to first- and second-line drugs, there is an urgent need for the development of new drugs to control the propagation of TB. Although screenings of small molecules on axenic M. tuberculosis cultures were successful for the identification of novel putative anti-TB drugs, new drugs in the development pipeline remains scarce. Host-directed therapy may represent an alternative for drug development against TB. Indeed, M. tuberculosis has multiple specific interactions within host phagocytes, which may be targeted by small molecules. In order to enable drug discovery strategies against microbes residing within host macrophages, we developed multiple fluorescence-based HT/CS phenotypic assays monitoring the intracellular replication of M. tuberculosis as well as its intracellular trafficking. What we propose here is a population-based, multi-parametric analysis pipeline that can be used to monitor the intracellular fate of M. tuberculosis and the dynamics of cellular events such as phagosomal maturation (acidification and permeabilization), zinc poisoning system or lipid body accumulation. Such analysis allows the quantification of biological events considering the host-pathogen interplay and may thus be derived to other intracellular pathogens. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  1. First results with a radioreceptor-assay (TRAK-Assay) for TSH-receptor-autoantibodies

    International Nuclear Information System (INIS)

    Becker, W.; Reiners, C.; Boerner, W.

    1983-01-01

    A new radioreceptor-assay (TRAK-assay) for autoantibodies against TSH-receptors was tested in 48 untreated thyrotoxic patients (26 regional autonomies, 22 toxic diffuse goiters). None of the 26 patients with regional autonomy showed positive autoantibody-titers. 4 patients with toxic diffuse goiter and thyrotoxic exophthalmos were TRAK-positive. Positive titers of microsomal and thyreoglobulin autoantibodies could be seen in 8 of 9 patients with positive TRAK-titers. In accordance with the conventional methods for detecting thyroid-stimulating immunoglobulins the new TRAK-assay seems to be suited for differentiating between immunogenic toxic diffuse goiter (Graves' disease) and goiter with disseminated autonomy as well as for prediction of relapse. (orig.) [de

  2. 2-Hydroxypyridine-N-oxide (HOPO): Equivocal in the ames assay.

    Science.gov (United States)

    Dobo, Krista L; Cheung, Jennifer R; Gunther, William C; Kenyon, Michelle O

    2018-05-01

    2-Hydroxypyridine-N-oxide (HOPO) is a useful coupling reagent for synthesis of active pharmaceutical ingredients. It has been reported to be weakly mutagenic in the Ames assay (Ding W et al. []: J Chromatogr A 1386:47-52). According to the ICH M7 guidance (2014) regarding control of mutagenic impurities to limit potential carcinogenic risk, mutagens require control in drug substances such that exposure not exceeds the threshold of toxicological concern. Given the weak response observed in the Ames assay and the lack of any obvious structural features that could confer DNA reactivity we were interested to determine if the results were reproducible and investigate the role of potentially confounding experimental parameters. Specifically, Ames tests were conducted to assess the influence of compound purity, solvent choice, dose spacing, toxicity, type of S9 (aroclor vs phenobarbital/β-napthoflavone), and lot variability on the frequency of HOPO induced revertant colonies. Initial extensive testing using one lot of HOPO produced no evidence of mutagenic potential in the Ames assays. Subsequent studies with four additional lots produced conflicting results, with an ∼2.0-fold increase in revertant colonies observed. Given the rigor of the current investigation, lack of reproducibility between lots, and the weak increase in revertants, it is concluded that HOPO is equivocal in the bacterial reverse mutation assay. It is highly unlikely that HOPO poses a mutagenic risk in vivo; therefore, when it is used as a reagent in pharmaceutical synthesis, it should not be regarded as a mutagenic impurity, but rather a normal process related impurity. Environ. Mol. Mutagen. 59:312-321, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  3. Introducing a true internal standard for the Comet assay to minimize intra- and inter-experiment variability in measures of DNA damage and repair

    Science.gov (United States)

    Zainol, Murizal; Stoute, Julia; Almeida, Gabriela M.; Rapp, Alexander; Bowman, Karen J.; Jones, George D. D.

    2009-01-01

    The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA. PMID:19828597

  4. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    Science.gov (United States)

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  5. Multiple sclerosis: general features and pharmacologic approach; Esclerosis multiple: aspectos generales y abordaje farmacologico

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen Lagumersindez, Denis; Martinez Sanchez, Gregorio [Instituto de Farmacia y Alimentos, Universidad de La Habana, La Habana (Cuba)

    2009-07-01

    Multiple sclerosis is an autoimmune, inflammatory and desmyelinization disease central nervous system (CNS) of unknown etiology and critical evolution. There different etiological hypotheses talking of a close interrelation among predisposing genetic factors and dissimilar environmental factors, able to give raise to autoimmune response at central nervous system level. Hypothesis of autoimmune pathogeny is based on study of experimental models, and findings in biopsies of affected patients by disease. Accumulative data report that the oxidative stress plays a main role in pathogenesis of multiple sclerosis. Oxygen reactive species generated by macrophages has been involved as mediators of demyelinization and of axon damage, in experimental autoimmune encephalomyelitis and strictly in multiple sclerosis. Disease diagnosis is difficult because of there is not a confirmatory unique test. Management of it covers the treatment of acute relapses, disease modification, and symptoms management. These features require an individualized approach, base on evolution of this affection, and tolerability of treatments. In addition to diet, among non-pharmacologic treatments for multiple sclerosis it is recommended physical therapy. Besides, some clinical assays have been performed in which we used natural extracts, nutrition supplements, and other agents with promising results. Pharmacology allowed neurologists with a broad array of proved effectiveness drugs; however, results of research laboratories in past years make probable that therapeutical possibilities increase notably in future. (Author)

  6. Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method

    International Nuclear Information System (INIS)

    Parodi, Roberto C.; Sardanelli, Francesco; Renzetti, Paolo; Rosso, Elisabetta; Losacco, Caterina; Ferrari, Alessandra; Levrero, Fabrizio; Pilot, Alberto; Inglese, Matilde; Mancardi, Giovanni L.

    2002-01-01

    Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing them to those obtained using manual contouring (MC). From routine 1.5-T MRI study of clinically definite multiple sclerosis patients, 36 lesions seen on proton-density-weighted images (PDWI) and 36 enhancing lesion on Gd-DTPA-BMA-enhanced T1-weighted images (Gd-T1WI) were randomly chosen and were evaluated by three observers. The mean range of lesion size was 9.9-536.0 mm 2 on PDWI and 3.6-57.2 mm 2 on Gd-T1WI. The median intra- and inter-observer agreement were, respectively, 97.1 and 90.0% using GRES on PDWI, 81.0 and 70.0% using MC on PDWI, 88.8 and 80.0% using GRES on Gd-T1WI, and 85.8 and 70.0% using MC on Gd-T1WI. The intra- and inter-observer agreements were significantly greater for GRES compared with MC (P<0.0001 and P=0.0023, respectively) for PDWI, while no difference was found between GRES an MC for Gd-T1WI. The intra-observer variability for GRES was significantly lower on both PDWI (P=0.0001) and Gd-T1WI (P=0.0067), whereas for MC the same result was found only for PDWI (P=0.0147). These data indicate that GRES reduces both the intra- and the inter-observer variability in assessing the area of MS lesions on PDWI and may prove useful in multicentre studies. (orig.)

  7. Variability of CSF Alzheimer's disease biomarkers: implications for clinical practice.

    Directory of Open Access Journals (Sweden)

    Stephanie J B Vos

    Full Text Available BACKGROUND: Cerebrospinal fluid (CSF biomarkers are increasingly being used for diagnosis of Alzheimer's disease (AD. OBJECTIVE: We investigated the influence of CSF intralaboratory and interlaboratory variability on diagnostic CSF-based AD classification of subjects and identified causes of this variation. METHODS: We measured CSF amyloid-β (Aβ 1-42, total tau (t-tau, and phosphorylated tau (p-tau by INNOTEST enzyme-linked-immunosorbent assays (ELISA in a memory clinic population (n = 126. Samples were measured twice in a single or two laboratories that served as reference labs for CSF analyses in the Netherlands. Predefined cut-offs were used to classify CSF biomarkers as normal or abnormal/AD pattern. RESULTS: CSF intralaboratory variability was higher for Aβ1-42 than for t-tau and p-tau. Reanalysis led to a change in biomarker classification (normal vs. abnormal of 26% of the subjects based on Aβ1-42, 10% based on t-tau, and 29% based on p-tau. The changes in absolute biomarker concentrations were paralleled by a similar change in levels of internal control samples between different assay lots. CSF interlaboratory variability was higher for p-tau than for Aβ1-42 and t-tau, and reanalysis led to a change in biomarker classification of 12% of the subjects based on Aβ1-42, 1% based on t-tau, and 22% based on p-tau. CONCLUSIONS: Intralaboratory and interlaboratory CSF variability frequently led to change in diagnostic CSF-based AD classification for Aβ1-42 and p-tau. Lot-to-lot variation was a major cause of intralaboratory variability. This will have implications for the use of these biomarkers in clinical practice.

  8. QUEST1 Variability Survey. II. Variability Determination Criteria and 200k Light Curve Catalog

    Science.gov (United States)

    Rengstorf, A. W.; Mufson, S. L.; Andrews, P.; Honeycutt, R. K.; Vivas, A. K.; Abad, C.; Adams, B.; Bailyn, C.; Baltay, C.; Bongiovanni, A.; Briceño, C.; Bruzual, G.; Coppi, P.; Della Prugna, F.; Emmet, W.; Ferrín, I.; Fuenmayor, F.; Gebhard, M.; Hernández, J.; Magris, G.; Musser, J.; Naranjo, O.; Oemler, A.; Rosenzweig, P.; Sabbey, C. N.; Sánchez, Ge.; Sánchez, Gu.; Schaefer, B.; Schenner, H.; Sinnott, J.; Snyder, J. A.; Sofia, S.; Stock, J.; van Altena, W.

    2004-12-01

    The QUEST (QUasar Equatorial Survey Team) Phase 1 camera has collected multibandpass photometry on a large strip of high Galactic latitude sky over a period of 26 months. This robust data set has been reduced and nightly catalogs compared to determine the photometric variability of the ensemble objects. Subsequent spectroscopic observations have confirmed a subset of the photometric variables as quasars, as previously reported. This paper reports on the details of the data reduction and analysis pipeline and presents multiple bandpass light curves for 198,213 QUEST1 objects, along with global variability information and matched Sloan photometry. Based on observations obtained at the Llano del Hato National Astronomical Observatory, operated by the Centro de Investigaciones de Astronomía for the Ministerio de Ciencia y Tecnologia of Venezuela.

  9. Immobilisation of barley aleurone layers enables parallelisation of assays and analysis of transient gene expression in single cells

    DEFF Research Database (Denmark)

    Zor, Kinga; Mark, Christina; Heiskanen, Arto

    2017-01-01

    at a single time point. By immobilising barley aleurone layer tissue on polydimethylsiloxane pillars in the lid of a multiwell plate, continuous monitoring of living tissue is enabled using multiple non-destructive assays in parallel. Cell viability and menadione reducing capacity were monitored in the same...

  10. 10 km running performance predicted by a multiple linear regression model with allometrically adjusted variables.

    Science.gov (United States)

    Abad, Cesar C C; Barros, Ronaldo V; Bertuzzi, Romulo; Gagliardi, João F L; Lima-Silva, Adriano E; Lambert, Mike I; Pires, Flavio O

    2016-06-01

    The aim of this study was to verify the power of VO 2max , peak treadmill running velocity (PTV), and running economy (RE), unadjusted or allometrically adjusted, in predicting 10 km running performance. Eighteen male endurance runners performed: 1) an incremental test to exhaustion to determine VO 2max and PTV; 2) a constant submaximal run at 12 km·h -1 on an outdoor track for RE determination; and 3) a 10 km running race. Unadjusted (VO 2max , PTV and RE) and adjusted variables (VO 2max 0.72 , PTV 0.72 and RE 0.60 ) were investigated through independent multiple regression models to predict 10 km running race time. There were no significant correlations between 10 km running time and either the adjusted or unadjusted VO 2max . Significant correlations (p 0.84 and power > 0.88. The allometrically adjusted predictive model was composed of PTV 0.72 and RE 0.60 and explained 83% of the variance in 10 km running time with a standard error of the estimate (SEE) of 1.5 min. The unadjusted model composed of a single PVT accounted for 72% of the variance in 10 km running time (SEE of 1.9 min). Both regression models provided powerful estimates of 10 km running time; however, the unadjusted PTV may provide an uncomplicated estimation.

  11. Using Derivative Estimates to Describe Intraindividual Variability at Multiple Time Scales

    Science.gov (United States)

    Deboeck, Pascal R.; Montpetit, Mignon A.; Bergeman, C. S.; Boker, Steven M.

    2009-01-01

    The study of intraindividual variability is central to the study of individuals in psychology. Previous research has related the variance observed in repeated measurements (time series) of individuals to traitlike measures that are logically related. Intraindividual measures, such as intraindividual standard deviation or the coefficient of…

  12. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics.

    Science.gov (United States)

    Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul

    2013-07-21

    Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.

  13. A quantitative TaqMan PCR assay for the detection of Ureaplasma diversum.

    Science.gov (United States)

    Marques, Lucas M; Amorim, Aline T; Martins, Hellen Braga; Rezende, Izadora Souza; Barbosa, Maysa Santos; Lobão, Tassia Neves; Campos, Guilherme B; Timenetsky, Jorge

    2013-12-27

    Ureaplasma diversum in veterinary studies is an undesirable microbe, which may cause infection in bulls and may result in seminal vesiculitis, balanopostitis, and alterations in spermatozoids, whereas in cows, it may cause placentitis, fetal alveolitis, abortion, and birth of weak calves. U. diversum is released through organic secretions, especially semen, preputial and vaginal mucus, conjunctival secretion, and milk. The aim of the present study was to develop a TaqMan probe, highly sensitive and specific quantitative PCR (qPCR) assay for the detection and quantification of U. diversum from genital swabs of bovines. Primers and probes specific to U. diversum 16S rRNA gene were designed. The specificity, detection limit, intra- and inter-assay variability of qPCR to detect this ureaplasma was compared with the results of the conventional PCR assay (cPCR). Swabs of vaginal mucus from 169 cows were tested. The qPCR assay detected as few as 10 copies of U. diversum and was 100-fold more sensitive than the cPCR. No cross-reactivity with other Mollicutes or eubacteria was observed. U. diversum was detected in 79 swabs (46.42%) by qPCR, while using cPCR it was detected in 42 (25%) samples. The difference in cPCR and qPCR ureaplasma detection between healthy and sick animals was not statistically significant. But the U. diversum load in samples from animals with genital disorders was higher than in healthy animals. The qPCR assay developed herein is highly sensitive and specific for the detection and quantification of U. diversum in vaginal bovine samples. Copyright © 2013. Published by Elsevier B.V.

  14. On the explaining-away phenomenon in multivariate latent variable models.

    Science.gov (United States)

    van Rijn, Peter; Rijmen, Frank

    2015-02-01

    Many probabilistic models for psychological and educational measurements contain latent variables. Well-known examples are factor analysis, item response theory, and latent class model families. We discuss what is referred to as the 'explaining-away' phenomenon in the context of such latent variable models. This phenomenon can occur when multiple latent variables are related to the same observed variable, and can elicit seemingly counterintuitive conditional dependencies between latent variables given observed variables. We illustrate the implications of explaining away for a number of well-known latent variable models by using both theoretical and real data examples. © 2014 The British Psychological Society.

  15. Designing neural networks that process mean values of random variables

    International Nuclear Information System (INIS)

    Barber, Michael J.; Clark, John W.

    2014-01-01

    We develop a class of neural networks derived from probabilistic models posed in the form of Bayesian networks. Making biologically and technically plausible assumptions about the nature of the probabilistic models to be represented in the networks, we derive neural networks exhibiting standard dynamics that require no training to determine the synaptic weights, that perform accurate calculation of the mean values of the relevant random variables, that can pool multiple sources of evidence, and that deal appropriately with ambivalent, inconsistent, or contradictory evidence. - Highlights: • High-level neural computations are specified by Bayesian belief networks of random variables. • Probability densities of random variables are encoded in activities of populations of neurons. • Top-down algorithm generates specific neural network implementation of given computation. • Resulting “neural belief networks” process mean values of random variables. • Such networks pool multiple sources of evidence and deal properly with inconsistent evidence

  16. Designing neural networks that process mean values of random variables

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Michael J. [AIT Austrian Institute of Technology, Innovation Systems Department, 1220 Vienna (Austria); Clark, John W. [Department of Physics and McDonnell Center for the Space Sciences, Washington University, St. Louis, MO 63130 (United States); Centro de Ciências Matemáticas, Universidade de Madeira, 9000-390 Funchal (Portugal)

    2014-06-13

    We develop a class of neural networks derived from probabilistic models posed in the form of Bayesian networks. Making biologically and technically plausible assumptions about the nature of the probabilistic models to be represented in the networks, we derive neural networks exhibiting standard dynamics that require no training to determine the synaptic weights, that perform accurate calculation of the mean values of the relevant random variables, that can pool multiple sources of evidence, and that deal appropriately with ambivalent, inconsistent, or contradictory evidence. - Highlights: • High-level neural computations are specified by Bayesian belief networks of random variables. • Probability densities of random variables are encoded in activities of populations of neurons. • Top-down algorithm generates specific neural network implementation of given computation. • Resulting “neural belief networks” process mean values of random variables. • Such networks pool multiple sources of evidence and deal properly with inconsistent evidence.

  17. Variable Nitrogen Fixation in Wild Populus.

    Directory of Open Access Journals (Sweden)

    Sharon L Doty

    Full Text Available The microbiome of plants is diverse, and like that of animals, is important for overall health and nutrient acquisition. In legumes and actinorhizal plants, a portion of essential nitrogen (N is obtained through symbiosis with nodule-inhabiting, N2-fixing microorganisms. However, a variety of non-nodulating plant species can also thrive in natural, low-N settings. Some of these species may rely on endophytes, microorganisms that live within plants, to fix N2 gas into usable forms. Here we report the first direct evidence of N2 fixation in the early successional wild tree, Populus trichocarpa, a non-leguminous tree, from its native riparian habitat. In order to measure N2 fixation, surface-sterilized cuttings of wild poplar were assayed using both 15N2 incorporation and the commonly used acetylene reduction assay. The 15N label was incorporated at high levels in a subset of cuttings, suggesting a high level of N-fixation. Similarly, acetylene was reduced to ethylene in some samples. The microbiota of the cuttings was highly variable, both in numbers of cultured bacteria and in genetic diversity. Our results indicated that associative N2-fixation occurred within wild poplar and that a non-uniformity in the distribution of endophytic bacteria may explain the variability in N-fixation activity. These results point to the need for molecular studies to decipher the required microbial consortia and conditions for effective endophytic N2-fixation in trees.

  18. Automation of complex assays: pharmacogenetics of warfarin dosing.

    Science.gov (United States)

    Wu, Whei-Kuo; Hujsak, Paul G; Kureshy, Fareed

    2007-10-01

    AutoGenomics, Inc. (Carlsbad, CA, USA) have developed a multiplex microarray assay for genotyping both VKORC1 and CYP2C9 using the INFINITI(™) Analyzer. Multiple alleles in each DNA sample are analyzed by polymerase chain reaction amplification, followed by detection primer extension using the INFINITI Analyzer. The INFINITI Analyzer performs single-nucleotide polymorphism (SNP) analysis using universal oligonucleotides immobilized on the biochip. To genotype broader ethnic groups, genomic DNA from whole blood was tested for nine SNPs for VKORC1 and six for CYP2C9 genotypes. Information related to all 15 SNPs is needed to determine dosing of population of diverse ethnic origin. The INFINITI system provides genotyping information for same day dosing of warfarin.

  19. A latent class multiple constraint multiple discrete-continuous extreme value model of time use and goods consumption.

    Science.gov (United States)

    2016-06-01

    This paper develops a microeconomic theory-based multiple discrete continuous choice model that considers: (a) that both goods consumption and time allocations (to work and non-work activities) enter separately as decision variables in the utility fu...

  20. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  1. Use of global assays to understand clinical phenotype in congenital factor VII deficiency.

    Science.gov (United States)

    Greene, L A; Goldenberg, N A; Simpson, M L; Villalobos-Menuey, E; Bombardier, C; Acharya, S S; Santiago-Borrero, P J; Cambara, A; DiMichele, D M

    2013-09-01

    Congenital factor VII (FVII) deficiency is characterized by genotypic variability and phenotypic heterogeneity. Traditional screening and factor assays are unable to reliably predict clinical bleeding phenotype and guide haemorrhage prevention strategy. Global assays of coagulation and fibrinolysis may better characterize overall haemostatic balance and aid in haemorrhagic risk assessment. We evaluated the ability of novel global assays to better understand clinical bleeding severity in congenital FVII deficiency. Subjects underwent central determination of factor VII activity (FVII:C) as well as clot formation and lysis (CloFAL) and simultaneous thrombin and plasmin generation (STP) global assay analysis. A bleeding score was assigned to each subject through medical chart review. Global assay parameters were analysed with respect to bleeding score and FVII:C. Subgroup analyses were performed on paediatric subjects and subjects with FVII ≥ 1 IU dL(-1). CloFAL fibrinolytic index (FI2 ) inversely correlated with FVII:C while CloFAL maximum amplitude (MA) and STP maximum velocity of thrombin generation (VT max) varied directly with FVII:C. CloFAL FI2 directly correlated with bleeding score among subjects in both the total cohort and paediatric subcohort, but not among subjects with FVII ≥ 1 IU dL(-1) . Among subjects with FVII ≥ 1 IU dL(-1), STP time to maximum velocity of thrombin generation and time to maximum velocity of plasmin generation inversely correlated with bleeding score. These preliminary findings suggest a novel potential link between a hyperfibrinolytic state in bleeding severity and congenital FVII deficiency, an observation that should be further explored. © 2013 John Wiley & Sons Ltd.

  2. TaqMan real-time PCR assays for single-nucleotide polymorphisms which identify Francisella tularensis and its subspecies and subpopulations.

    Directory of Open Access Journals (Sweden)

    Dawn N Birdsell

    Full Text Available Francisella tularensis, the etiologic agent of tularemia and a Class A Select Agent, is divided into three subspecies and multiple subpopulations that differ in virulence and geographic distribution. Given these differences, there is a need to rapidly and accurately determine if a strain is F. tularensis and, if it is, assign it to subspecies and subpopulation. We designed TaqMan real-time PCR genotyping assays using eleven single nucleotide polymorphisms (SNPs that were potentially specific to closely related groups within the genus Francisella, including numerous subpopulations within F. tularensis species. We performed extensive validation studies to test the specificity of these SNPs to particular populations by screening the assays across a set of 565 genetically and geographically diverse F. tularensis isolates and an additional 21 genetic near-neighbor (outgroup isolates. All eleven assays correctly determined the genetic groups of all 565 F. tularensis isolates. One assay differentiates F. tularensis, F. novicida, and F. hispaniensis from the more genetically distant F. philomiragia and Francisella-like endosymbionts. Another assay differentiates F. tularensis isolates from near neighbors. The remaining nine assays classify F. tularensis-confirmed isolates into F. tularensis subspecies and subpopulations. The genotyping accuracy of these nine assays diminished when tested on outgroup isolates (i.e. non F. tularensis, therefore a hierarchical approach of assay usage is recommended wherein the F. tularensis-specific assay is used before the nine downstream assays. Among F. tularensis isolates, all eleven assays were highly sensitive, consistently amplifying very low concentrations of DNA. Altogether, these eleven TaqMan real-time PCR assays represent a highly accurate, rapid, and sensitive means of identifying the species, subspecies, and subpopulation of any F. tularensis isolate if used in a step-wise hierarchical scheme. These assays

  3. Establishment and intra-/inter-laboratory validation of a standard protocol of reactive oxygen species assay for chemical photosafety evaluation.

    Science.gov (United States)

    Onoue, Satomi; Hosoi, Kazuhiro; Wakuri, Shinobu; Iwase, Yumiko; Yamamoto, Toshinobu; Matsuoka, Naoko; Nakamura, Kazuichi; Toda, Tsuguto; Takagi, Hironori; Osaki, Naoto; Matsumoto, Yasuhiro; Kawakami, Satoru; Seto, Yoshiki; Kato, Masashi; Yamada, Shizuo; Ohno, Yasuo; Kojima, Hajime

    2013-11-01

    A reactive oxygen species (ROS) assay was previously developed for photosafety evaluation of pharmaceuticals, and the present multi-center study aimed to establish and validate a standard protocol for ROS assay. In three participating laboratories, two standards and 42 coded chemicals, including 23 phototoxins and 19 nonphototoxic drugs/chemicals, were assessed by the ROS assay according to the standardized protocol. Most phototoxins tended to generate singlet oxygen and/or superoxide under UV-vis exposure, but nonphototoxic chemicals were less photoreactive. In the ROS assay on quinine (200 µm), a typical phototoxic drug, the intra- and inter-day precisions (coefficient of variation; CV) were found to be 1.5-7.4% and 1.7-9.3%, respectively. The inter-laboratory CV for quinine averaged 15.4% for singlet oxygen and 17.0% for superoxide. The ROS assay on 42 coded chemicals (200 µm) provided no false negative predictions upon previously defined criteria as compared with the in vitro/in vivo phototoxicity, although several false positives appeared. Outcomes from the validation study were indicative of satisfactory transferability, intra- and inter-laboratory variability, and predictive capacity of the ROS assay. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Variable sensory perception in autism.

    Science.gov (United States)

    Haigh, Sarah M

    2018-03-01

    Autism is associated with sensory and cognitive abnormalities. Individuals with autism generally show normal or superior early sensory processing abilities compared to healthy controls, but deficits in complex sensory processing. In the current opinion paper, it will be argued that sensory abnormalities impact cognition by limiting the amount of signal that can be used to interpret and interact with environment. There is a growing body of literature showing that individuals with autism exhibit greater trial-to-trial variability in behavioural and cortical sensory responses. If multiple sensory signals that are highly variable are added together to process more complex sensory stimuli, then this might destabilise later perception and impair cognition. Methods to improve sensory processing have shown improvements in more general cognition. Studies that specifically investigate differences in sensory trial-to-trial variability in autism, and the potential changes in variability before and after treatment, could ascertain if trial-to-trial variability is a good mechanism to target for treatment in autism. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  5. Multiple endocrine neoplasia type 2: achievements and current challenges

    Directory of Open Access Journals (Sweden)

    Andreas Machens

    2012-01-01

    Full Text Available Incremental advances in medical technology, such as the development of sensitive hormonal assays for routine clinical care, are the drivers of medical progress. This principle is exemplified by the creation of the concept of multiple endocrine neoplasia type 2, encompassing medullary thyroid cancer, pheochromocytoma, and primary hyperparathyroidism, which did not emerge before the early 1960s. This review sets out to highlight key achievements, such as joint biochemical and DNA-based screening of individuals at risk of developing multiple endocrine neoplasia type 2, before casting a spotlight on current challenges which include: (i ill-defined upper limits of calcitonin assays for infants and young children, rendering it difficult to implement the biochemical part of the integrated DNA-based/biochemical concept; (ii our increasingly mobile society in which different service providers are caring for one individual at various stages in the disease process. With familial relationships disintegrating as a result of geographic dispersion, information about the history of the origin family may become sketchy or just unavailable. This is when DNA-based gene tests come into play, confirming or excluding an individual's genetic predisposition to multiple endocrine neoplasia type 2 even before there is any biochemical or clinical evidence of the disease. However, the unrivaled molecular genetic progress in multiple endocrine neoplasia type 2 does not come without a price. Screening may uncover unknown gene sequence variants representing either harmless polymorphisms or pathogenic mutations. In this setting, functional characterization of mutant cells in vitro may generate helpful ancillary evidence with regard to the pathogenicity of gene variants in comparison with established mutations.

  6. A laboratory-scale pretreatment and hydrolysis assay for determination of reactivity in cellulosic biomass feedstocks.

    Science.gov (United States)

    Wolfrum, Edward J; Ness, Ryan M; Nagle, Nicholas J; Peterson, Darren J; Scarlata, Christopher J

    2013-11-14

    The rapid determination of the release of structural sugars from biomass feedstocks is an important enabling technology for the development of cellulosic biofuels. An assay that is used to determine sugar release for large numbers of samples must be robust, rapid, and easy to perform, and must use modest amounts of the samples to be tested.In this work we present a laboratory-scale combined pretreatment and saccharification assay that can be used as a biomass feedstock screening tool. The assay uses a commercially available automated solvent extraction system for pretreatment followed by a small-scale enzymatic hydrolysis step. The assay allows multiple samples to be screened simultaneously, and uses only ~3 g of biomass per sample. If the composition of the biomass sample is known, the results of the assay can be expressed as reactivity (fraction of structural carbohydrate present in the biomass sample released as monomeric sugars). We first present pretreatment and enzymatic hydrolysis experiments on a set of representative biomass feedstock samples (corn stover, poplar, sorghum, switchgrass) in order to put the assay in context, and then show the results of the assay applied to approximately 150 different feedstock samples covering 5 different materials. From the compositional analysis data we identify a positive correlation between lignin and structural carbohydrates, and from the reactivity data we identify a negative correlation between both carbohydrate and lignin content and total reactivity. The negative correlation between lignin content and total reactivity suggests that lignin may interfere with sugar release, or that more mature samples (with higher structural sugars) may have more recalcitrant lignin. The assay presented in this work provides a robust and straightforward method to measure the sugar release after pretreatment and saccharification that can be used as a biomass feedstock screening tool. We demonstrated the utility of the assay by

  7. Testing candidate genes for attention-deficit/hyperactivity disorder in fruit flies using a high throughput assay for complex behavior

    DEFF Research Database (Denmark)

    Rohde, Palle Duun; Madsen, Lisbeth Strøm; Arvidson, Sandra Marie Neumann

    2016-01-01

    Fruit flies are important model organisms for functional testing of candidate genes in multiple disciplines, including the study of human diseases. Here we use a high-throughput locomotor activity assay to test the response on activity behavior of gene disruption in Drosophila melanogaster. The aim...

  8. Hemocytes of zebra mussels (Dreissena polymorpha are relevant cells for the monitoring of environmental genotoxicity by the comet assay.

    Directory of Open Access Journals (Sweden)

    Marc Bonnard

    2015-06-01

    Full Text Available The measure of DNA integrity by the single cell gel electrophoresis (SCGE or comet assay is especially recommended for its sensitivity and its capacity for detecting different types of damages. Therefore, it has been applied in environmental genotoxicity in a variety of organisms. It appears today necessary to define both reference and threshold levels of DNA damage, for their application in in situ biomonitoring. However, little is known about the influence of both biological (sex, reproduction status or external (temperature… confounding factors on the measure of DNA damage by the comet assay. These variables need to be taken into account if the robustness of the assay is to be established (Jha, 2008. In the zebra mussel Dreissena polymorpha (recommended as a sentinel species in the evaluation of freshwater quality the measure of DNA damage by the comet assay is mainly performed on hemocytes, which are circulating cells involved in key physiological functions such as immunity, homeostasis, detoxication…. This communication will present and discuss results from an innovative study about the variability of the baseline level of DNA damage in hemocytes of mussels encaged for one year in the canal de l’Aisne à la Marne (Reims, according to their sex and their reproductive status. The sensitivity and the suitability of hemocytes in the evaluation of environmental genotoxicity will also be discussed, referring to observations during a 6 month-exposure of mussels in mesocosms to environmentally realistic concentrations of carbamazepine.

  9. Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.

    Science.gov (United States)

    Di Donna, Leonardo; Taverna, Domenico; Indelicato, Serena; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio

    2017-08-15

    A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Radioactive wastes assay technique and equipment

    International Nuclear Information System (INIS)

    Lee, K. M.; Hong, D. S; Kim, T. K.; Bae, S. M.; Shon, J. S.; Hong, K. P.

    2004-12-01

    The waste inventory records such as the activities and radio- nuclides contained in the waste packages are to be submitted with the radioactive wastes packages for the final disposal. The nearly around 10,000 drums of waste stocked in KAERI now should be assayed for the preparation of the waste inventory records too. For the successive execution of the waste assay, the investigation into the present waste assay techniques and equipment are to be taken first. Also the installation of the waste assay equipment through the comprehensive design, manufacturing and procurement should be proceeded timely. As the characteristics of the KAERI-stocked wastes are very different from that of the nuclear power plant and those have no regular waste streams, the application of the in-direct waste assay method using the scaling factors are not effective for the KAERI-generated wastes. Considering for the versal conveniency including the accuracy over the wide range of waste forms and the combination of assay time and sensitivity, the TGS(Tomographic Gamma Scanner) is appropriate as for the KAERI -generated radioactive waste assay equipment

  11. Critical issues with the in vivo comet assay: A report of the comet assay working group in the 6th International Workshop on Genotoxicity Testing (IWGT).

    Science.gov (United States)

    Speit, Günter; Kojima, Hajime; Burlinson, Brian; Collins, Andrew R; Kasper, Peter; Plappert-Helbig, Ulla; Uno, Yoshifumi; Vasquez, Marie; Beevers, Carol; De Boeck, Marlies; Escobar, Patricia A; Kitamoto, Sachiko; Pant, Kamala; Pfuhler, Stefan; Tanaka, Jin; Levy, Dan D

    2015-05-01

    As a part of the 6th IWGT, an expert working group on the comet assay evaluated critical topics related to the use of the in vivo comet assay in regulatory genotoxicity testing. The areas covered were: identification of the domain of applicability and regulatory acceptance, identification of critical parameters of the protocol and attempts to standardize the assay, experience with combination and integration with other in vivo studies, demonstration of laboratory proficiency, sensitivity and power of the protocol used, use of different tissues, freezing of samples, and choice of appropriate measures of cytotoxicity. The standard protocol detects various types of DNA lesions but it does not detect all types of DNA damage. Modifications of the standard protocol may be used to detect additional types of specific DNA damage (e.g., cross-links, bulky adducts, oxidized bases). In addition, the working group identified critical parameters that should be carefully controlled and described in detail in every published study protocol. In vivo comet assay results are more reliable if they were obtained in laboratories that have demonstrated proficiency. This includes demonstration of adequate response to vehicle controls and an adequate response to a positive control for each tissue being examined. There was a general agreement that freezing of samples is an option but more data are needed in order to establish generally accepted protocols. With regard to tissue toxicity, the working group concluded that cytotoxicity could be a confounder of comet results. It is recommended to look at multiple parameters such as histopathological observations, organ-specific clinical chemistry as well as indicators of tissue inflammation to decide whether compound-specific toxicity might influence the result. The expert working group concluded that the alkaline in vivo comet assay is a mature test for the evaluation of genotoxicity and can be recommended to regulatory agencies for use

  12. Saccharification Performances of Miscanthus at the Pilot and Miniaturized Assay Scales: Genotype and Year Variabilities According to the Biomass Composition

    Directory of Open Access Journals (Sweden)

    Nassim Belmokhtar

    2017-05-01

    Full Text Available HIGHLIGHTSBiomass production and cell wall composition are differentially impacted by harvesting year and genotypes, influencing then cellulose conversion in miniaturized assay.Using a high-throughput miniaturized and semi-automated method for performing the pretreatment and saccharification steps at laboratory scale allows for the assessment of these factors on the biomass potential for producing bioethanol before moving to the industrial scale.The large genetic diversity of the perennial grass miscanthus makes it suitable for producing cellulosic ethanol in biorefineries. The saccharification potential and year variability of five genotypes belonging to Miscanthus × giganteus and Miscanthus sinensis were explored using a miniaturized and semi-automated method, allowing the application of a hot water treatment followed by an enzymatic hydrolysis. The studied genotypes highlighted distinct cellulose conversion yields due to their distinct cell wall compositions. An inter-year comparison revealed significant variations in the biomass productivity and cell wall compositions. Compared to the recalcitrant genotypes, more digestible genotypes contained higher amounts of hemicellulosic carbohydrates and lower amounts of cellulose and lignin. In contrast to hemicellulosic carbohydrates, the relationships analysis between the biomass traits and cellulose conversion clearly showed the same negative effect of cellulose and lignin on cellulose digestion. The miniaturized and semi-automated method we developed was usable at the laboratory scale and was reliable for mimicking the saccharification at the pilot scale using a steam explosion pretreatment and enzymatic hydrolysis. Therefore, this miniaturized method will allow the reliable screening of many genotypes for saccharification potential. These findings provide valuable information and tools for breeders to create genotypes combining high yield, suitable biomass composition, and high saccharification

  13. Biological Sampling Variability Study

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-08

    There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65

  14. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    Findlay, D.J.S.; Green, T.H.; Molesworth, T.V.; Staniforth, D.; Strachan, N.R.; Rogers, J.D.; Wise, M.O.; Forrest, K.R.

    1992-01-01

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  15. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  16. A force-based, parallel assay for the quantification of protein-DNA interactions.

    Science.gov (United States)

    Limmer, Katja; Pippig, Diana A; Aschenbrenner, Daniela; Gaub, Hermann E

    2014-01-01

    Analysis of transcription factor binding to DNA sequences is of utmost importance to understand the intricate regulatory mechanisms that underlie gene expression. Several techniques exist that quantify DNA-protein affinity, but they are either very time-consuming or suffer from possible misinterpretation due to complicated algorithms or approximations like many high-throughput techniques. We present a more direct method to quantify DNA-protein interaction in a force-based assay. In contrast to single-molecule force spectroscopy, our technique, the Molecular Force Assay (MFA), parallelizes force measurements so that it can test one or multiple proteins against several DNA sequences in a single experiment. The interaction strength is quantified by comparison to the well-defined rupture stability of different DNA duplexes. As a proof-of-principle, we measured the interaction of the zinc finger construct Zif268/NRE against six different DNA constructs. We could show the specificity of our approach and quantify the strength of the protein-DNA interaction.

  17. A force-based, parallel assay for the quantification of protein-DNA interactions.

    Directory of Open Access Journals (Sweden)

    Katja Limmer

    Full Text Available Analysis of transcription factor binding to DNA sequences is of utmost importance to understand the intricate regulatory mechanisms that underlie gene expression. Several techniques exist that quantify DNA-protein affinity, but they are either very time-consuming or suffer from possible misinterpretation due to complicated algorithms or approximations like many high-throughput techniques. We present a more direct method to quantify DNA-protein interaction in a force-based assay. In contrast to single-molecule force spectroscopy, our technique, the Molecular Force Assay (MFA, parallelizes force measurements so that it can test one or multiple proteins against several DNA sequences in a single experiment. The interaction strength is quantified by comparison to the well-defined rupture stability of different DNA duplexes. As a proof-of-principle, we measured the interaction of the zinc finger construct Zif268/NRE against six different DNA constructs. We could show the specificity of our approach and quantify the strength of the protein-DNA interaction.

  18. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  19. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  20. Optimization of a colorimetric assay for glycosylated human serum albumin

    International Nuclear Information System (INIS)

    Bohney, J.P.; Feldhoff, R.C.

    1986-01-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100 0 C. A NaBH 4 reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with [ 3 H]glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation

  1. MS transport assays for γ-aminobutyric acid transporters--an efficient alternative for radiometric assays.

    Science.gov (United States)

    Schmitt, Sebastian; Höfner, Georg; Wanner, Klaus T

    2014-08-05

    Transport assays for neurotransmitters based on radiolabeled substrates are widely spread and often indispensable in basic research and the drug development process, although the use of radioisotopes is inherently coupled to issues concerning radioactive waste and safety precautions. To overcome these disadvantages, we developed mass spectrometry (MS)-based transport assays for γ-aminobutyric acid (GABA), which is the major inhibitory neurotransmitter in the central nervous system (CNS). These "MS Transport Assays" provide all capabilities of [(3)H]GABA transport assays and therefore represent the first substitute for the latter. The performance of our approach is demonstrated for GAT1, the most important GABA transporter (GAT) subtype. As GABA is endogenously present in COS-7 cells employed as hGAT1 expression system, ((2)H6)GABA was used as a substrate to differentiate transported from endogenous GABA. To record transported ((2)H6)GABA, a highly sensitive, short, robust, and reliable HILIC-ESI-MS/MS quantification method using ((2)H2)GABA as an internal standard was developed and validated according to the Center for Drug Evaluation and Research (CDER) guidelines. Based on this LC-MS quantification, a setup to characterize hGAT1 mediated ((2)H6)GABA transport in a 96-well format was established, that enables automated processing and avoids any sample preparation. The K(m) value for ((2)H6)GABA determined for hGAT1 is in excellent agreement with results obtained from [(3)H]GABA uptake assays. In addition, the established assay format enables efficient determination of the inhibitory potency of GAT1 inhibitors, is capable of identifying those inhibitors transported as substrates, and furthermore allows characterization of efflux. The approach described here combines the strengths of LC-MS/MS with the high efficiency of transport assays based on radiolabeled substrates and is applicable to all GABA transporter subtypes.

  2. Environmental variables measured at multiple spatial scales exert uneven influence on fish assemblages of floodplain lakes

    Science.gov (United States)

    Dembkowski, Daniel J.; Miranda, Leandro E.

    2014-01-01

    We examined the interaction between environmental variables measured at three different scales (i.e., landscape, lake, and in-lake) and fish assemblage descriptors across a range of over 50 floodplain lakes in the Mississippi Alluvial Valley of Mississippi and Arkansas. Our goal was to identify important local- and landscape-level determinants of fish assemblage structure. Relationships between fish assemblage structure and variables measured at broader scales (i.e., landscape-level and lake-level) were hypothesized to be stronger than relationships with variables measured at finer scales (i.e., in-lake variables). Results suggest that fish assemblage structure in floodplain lakes was influenced by variables operating on three different scales. However, and contrary to expectations, canonical correlations between in-lake environmental characteristics and fish assemblage structure were generally stronger than correlations between landscape-level and lake-level variables and fish assemblage structure, suggesting a hierarchy of influence. From a resource management perspective, our study suggests that landscape-level and lake-level variables may be manipulated for conservation or restoration purposes, and in-lake variables and fish assemblage structure may be used to monitor the success of such efforts.

  3. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  4. Genotoxicity testing: Comparison of the γH2AX focus assay with the alkaline and neutral comet assays.

    Science.gov (United States)

    Nikolova, Teodora; Marini, Federico; Kaina, Bernd

    2017-10-01

    Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier

  5. Dose-Response Assessment of Four Genotoxic Chemicals in a Combined Mouse and Rat Micronucleus and Comet Assay Protocol

    Science.gov (United States)

    Recio, Leslie; Hobbs, Cheryl; Caspary, William; Witt, Kristine L.

    2012-01-01

    The in vivo micronucleus (MN) assay has proven to be an effective measure of genotoxicity potential. However, sampling a single tissue (bone marrow) for a single indicator of genetic damage using the MN assay provides a limited genotoxicity profile. The in vivo alkaline (pH>13) Comet assay, which detects a broad spectrum of DNA damage, can be applied to a variety of rodent tissues following administration of test agents. To determine if the Comet assay is a useful supplement to the in vivo MN assay, a combined test protocol (MN/Comet assay) was conducted in male B6C3F1 mice and F344/N rats using four model genotoxicants: ethyl methanesulfonate (EMS), acrylamide (ACM), cyclophosphamide (CP), and vincristine sulfate (VS). Test compounds were administered on 4 consecutive days at 24-hour intervals (VS was administered to rats for 3 days); animals were euthanized 4 hours after the last administration. All compounds induced significant increases in micronucleated reticulocytes (MN-RET) in the peripheral blood of mice, and all but ACM induced MN-RET in rats. EMS and ACM induced significant increases in DNA damage, measured by the Comet assay, in multiple tissues of mice and rats. CP-induced DNA damage was detected in leukocytes and duodenum cells. VS, a spindle fiber disrupting agent, was negative in the Comet assay. Based on these results, the MN/Comet assay holds promise for providing more comprehensive assessments of potential genotoxicants, and the National Toxicology Program is presently using this combined protocol in its overall evaluation of the genotoxicity of substances of public health concern. PMID:20371966

  6. Homogeneity analysis with k sets of variables: An alternating least squares method with optimal scaling features

    NARCIS (Netherlands)

    van der Burg, Eeke; de Leeuw, Jan; Verdegaal, Renée

    1988-01-01

    Homogeneity analysis, or multiple correspondence analysis, is usually applied tok separate variables. In this paper we apply it to sets of variables by using sums within sets. The resulting technique is called OVERALS. It uses the notion of optimal scaling, with transformations that can be multiple

  7. Two-Way Regularized Fuzzy Clustering of Multiple Correspondence Analysis.

    Science.gov (United States)

    Kim, Sunmee; Choi, Ji Yeh; Hwang, Heungsun

    2017-01-01

    Multiple correspondence analysis (MCA) is a useful tool for investigating the interrelationships among dummy-coded categorical variables. MCA has been combined with clustering methods to examine whether there exist heterogeneous subclusters of a population, which exhibit cluster-level heterogeneity. These combined approaches aim to classify either observations only (one-way clustering of MCA) or both observations and variable categories (two-way clustering of MCA). The latter approach is favored because its solutions are easier to interpret by providing explicitly which subgroup of observations is associated with which subset of variable categories. Nonetheless, the two-way approach has been built on hard classification that assumes observations and/or variable categories to belong to only one cluster. To relax this assumption, we propose two-way fuzzy clustering of MCA. Specifically, we combine MCA with fuzzy k-means simultaneously to classify a subgroup of observations and a subset of variable categories into a common cluster, while allowing both observations and variable categories to belong partially to multiple clusters. Importantly, we adopt regularized fuzzy k-means, thereby enabling us to decide the degree of fuzziness in cluster memberships automatically. We evaluate the performance of the proposed approach through the analysis of simulated and real data, in comparison with existing two-way clustering approaches.

  8. Multicentre comparison of a diagnostic assay

    DEFF Research Database (Denmark)

    Waters, Patrick; Reindl, Markus; Saiz, Albert

    2016-01-01

    ) assays in neuromyelitis optica spectrum disorders (NMOSD). METHODS: Coded samples from patients with neuromyelitis optica (NMO) or NMOSD (101) and controls (92) were tested at 15 European diagnostic centres using 21 assays including live (n=3) or fixed cell-based assays (n=10), flow cytometry (n=4...

  9. An ultrafiltration assay for lysyl oxidase

    International Nuclear Information System (INIS)

    Shackleton, D.R.; Hulmes, D.J.

    1990-01-01

    A modification of the original microdistillation assay for lysyl oxidase is described in which Amicon C-10 microconcentrators are used to separate, by ultrafiltration, the 3H-labeled products released from a [4,5-3H]-lysine-labeled elastin substrate. Enzyme activity is determined by scintillation counting of the ultrafiltrate, after subtraction of radioactivity released in the presence of beta-aminopropionitrile, a specific inhibitor of the enzyme. Conditions are described which optimize both the sensitivity and the efficient use of substrate. The assay shows linear inhibition of activity in up to 1 M urea; hence, as the enzyme is normally diluted in the assay, samples in 6 M urea can be assayed directly, without prior dialysis, and corrected for partial inhibition. Comparable results are obtained when enzyme activity is assayed by ultrafiltration or microdistillation. The assay is simple and convenient and, by using disposable containers throughout, it eliminates the need for time-consuming decontamination of radioactive glassware

  10. Development and evaluation of a bioinformatics approach for designing molecular assays for viral detection.

    Directory of Open Access Journals (Sweden)

    Pierre H H Schneeberger

    Full Text Available Viruses belonging to the Flaviviridae and Bunyaviridae families show considerable genetic diversity. However, this diversity is not necessarily taken into account when developing diagnostic assays, which are often based on the pairwise alignment of a limited number of sequences. Our objective was to develop and evaluate a bioinformatics workflow addressing two recurrent issues of molecular assay design: (i the high intraspecies genetic diversity in viruses and (ii the potential for cross-reactivity with close relatives.The workflow developed herein was based on two consecutive BLASTn steps; the first was utilized to select highly conserved regions among the viral taxon of interest, and the second was employed to assess the degree of similarity of these highly-conserved regions to close relatives. Subsequently, the workflow was tested on a set of eight viral species, including various strains from the Flaviviridae and Bunyaviridae families.The genetic diversity ranges from as low as 0.45% variable sites over the complete genome of the Japanese encephalitis virus to more than 16% of variable sites on segment L of the Crimean-Congo hemorrhagic fever virus. Our proposed bioinformatics workflow allowed the selection-based on computing scores-of the best target for a diagnostic molecular assay for the eight viral species investigated.Our bioinformatics workflow allowed rapid selection of highly conserved and specific genomic fragments among the investigated viruses, while considering up to several hundred complete genomic sequences. The pertinence of this workflow will increase in parallel to the number of sequences made publicly available. We hypothesize that our workflow might be utilized to select diagnostic molecular markers for higher organisms with more complex genomes, provided the sequences are made available.

  11. Quantifying the Stock of Soil Organic Carbon using Multiple ...

    African Journals Online (AJOL)

    The stepwise multiple regression model was employed to identify ecological variables that explained significant variation of carbon in fallow soils. Using fallow genealogical cycles of 1st, 2nd, 3rd, 4th and 5th generations, soil and vegetation variables from 30 sampling plots were collected and subjected to linear regression ...

  12. Detection of bifurcations in noisy coupled systems from multiple time series

    International Nuclear Information System (INIS)

    Williamson, Mark S.; Lenton, Timothy M.

    2015-01-01

    We generalize a method of detecting an approaching bifurcation in a time series of a noisy system from the special case of one dynamical variable to multiple dynamical variables. For a system described by a stochastic differential equation consisting of an autonomous deterministic part with one dynamical variable and an additive white noise term, small perturbations away from the system's fixed point will decay slower the closer the system is to a bifurcation. This phenomenon is known as critical slowing down and all such systems exhibit this decay-type behaviour. However, when the deterministic part has multiple coupled dynamical variables, the possible dynamics can be much richer, exhibiting oscillatory and chaotic behaviour. In our generalization to the multi-variable case, we find additional indicators to decay rate, such as frequency of oscillation. In the case of approaching a homoclinic bifurcation, there is no change in decay rate but there is a decrease in frequency of oscillations. The expanded method therefore adds extra tools to help detect and classify approaching bifurcations given multiple time series, where the underlying dynamics are not fully known. Our generalisation also allows bifurcation detection to be applied spatially if one treats each spatial location as a new dynamical variable. One may then determine the unstable spatial mode(s). This is also something that has not been possible with the single variable method. The method is applicable to any set of time series regardless of its origin, but may be particularly useful when anticipating abrupt changes in the multi-dimensional climate system

  13. Detection of bifurcations in noisy coupled systems from multiple time series

    Science.gov (United States)

    Williamson, Mark S.; Lenton, Timothy M.

    2015-03-01

    We generalize a method of detecting an approaching bifurcation in a time series of a noisy system from the special case of one dynamical variable to multiple dynamical variables. For a system described by a stochastic differential equation consisting of an autonomous deterministic part with one dynamical variable and an additive white noise term, small perturbations away from the system's fixed point will decay slower the closer the system is to a bifurcation. This phenomenon is known as critical slowing down and all such systems exhibit this decay-type behaviour. However, when the deterministic part has multiple coupled dynamical variables, the possible dynamics can be much richer, exhibiting oscillatory and chaotic behaviour. In our generalization to the multi-variable case, we find additional indicators to decay rate, such as frequency of oscillation. In the case of approaching a homoclinic bifurcation, there is no change in decay rate but there is a decrease in frequency of oscillations. The expanded method therefore adds extra tools to help detect and classify approaching bifurcations given multiple time series, where the underlying dynamics are not fully known. Our generalisation also allows bifurcation detection to be applied spatially if one treats each spatial location as a new dynamical variable. One may then determine the unstable spatial mode(s). This is also something that has not been possible with the single variable method. The method is applicable to any set of time series regardless of its origin, but may be particularly useful when anticipating abrupt changes in the multi-dimensional climate system.

  14. Detection of bifurcations in noisy coupled systems from multiple time series

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Mark S., E-mail: m.s.williamson@exeter.ac.uk; Lenton, Timothy M. [Earth System Science Group, College of Life and Environmental Sciences, University of Exeter, Laver Building, North Park Road, Exeter EX4 4QE (United Kingdom)

    2015-03-15

    We generalize a method of detecting an approaching bifurcation in a time series of a noisy system from the special case of one dynamical variable to multiple dynamical variables. For a system described by a stochastic differential equation consisting of an autonomous deterministic part with one dynamical variable and an additive white noise term, small perturbations away from the system's fixed point will decay slower the closer the system is to a bifurcation. This phenomenon is known as critical slowing down and all such systems exhibit this decay-type behaviour. However, when the deterministic part has multiple coupled dynamical variables, the possible dynamics can be much richer, exhibiting oscillatory and chaotic behaviour. In our generalization to the multi-variable case, we find additional indicators to decay rate, such as frequency of oscillation. In the case of approaching a homoclinic bifurcation, there is no change in decay rate but there is a decrease in frequency of oscillations. The expanded method therefore adds extra tools to help detect and classify approaching bifurcations given multiple time series, where the underlying dynamics are not fully known. Our generalisation also allows bifurcation detection to be applied spatially if one treats each spatial location as a new dynamical variable. One may then determine the unstable spatial mode(s). This is also something that has not been possible with the single variable method. The method is applicable to any set of time series regardless of its origin, but may be particularly useful when anticipating abrupt changes in the multi-dimensional climate system.

  15. Tehran Survey of Potential Risk Factors for Multiple Births

    Directory of Open Access Journals (Sweden)

    Reza Omani Samani

    2017-09-01

    Full Text Available Background The multiple pregnancy incidence is increasing worldwide. This increased incidence is concerning to the health care system. This study aims to determine the frequency of multiple pregnancy and identify factors that affect this frequency in Tehran, Iran. Materials and Methods This cross-sectional study included 5170 mothers in labor between July 6-21, 2015 from 103 hospitals with Obstetrics and Gynecology Wards. The questionnaire used in this study consisted of five parts: demographic characteristics; information related to pregnancy; information related to the infant; information regarding the multiple pregnancy; and information associated with infertility. We recruited 103 trained midwives to collect data related to the questionnaire from eligible participants through an interview and medical records review. Frequencies and odds ratios (OR for the association between multiple pregnancy and the selected characteristics (maternal age, economic status, history of multiple pregnancy in first-degree relatives, and reproductive history were computed by multiple logistic regression. Stata software, version 13 (Stata Corp, College Station, TX, USA was used for all statistical analyses. Results Multiple pregnancy had a prevalence of 1.48% [95% confidence interval (CI: 1.19-1.85]. After controlling for confounding variables, we observed a significant association between frequency of multiple pregnancy and mother’s age (OR=1.04, 95% CI: 1.001-1.09, P=0.044, assisted reproductive technique (ART, OR=6.11, 95% CI: 1.7- 21.97, P=0.006, and history of multiple pregnancy in the mother’s family (OR=5.49, 95% CI: 3.55-9.93, P=0.001. Conclusion The frequency of multiple pregnancy approximated results reported in previous studies in Iran. Based on the results, we observed significantly greater frequency of multiple pregnancy in older women, those with a history of ART, and a history of multiple pregnancy in the mother’s family compared to the other

  16. Changes in heart rate variability and QT variability during the first trimester of pregnancy.

    Science.gov (United States)

    Carpenter, R E; D'Silva, L A; Emery, S J; Uzun, O; Rassi, D; Lewis, M J

    2015-03-01

    The risk of new-onset arrhythmia during pregnancy is high, presumably relating to changes in both haemodynamic and cardiac autonomic function. The ability to non-invasively assess an individual's risk of developing arrhythmia during pregnancy would therefore be clinically significant. We aimed to quantify electrocardiographic temporal characteristics during the first trimester of pregnancy and to compare these with non-pregnant controls. Ninety-nine pregnant women and sixty-three non-pregnant women underwent non-invasive cardiovascular and haemodynamic assessment during a protocol consisting of various physiological states (postural manoeurvres, light exercise and metronomic breathing). Variables measured included stroke volume, cardiac output, heart rate, heart rate variability, QT and QT variability and QTVI (a measure of the variability of QT relative to that of RR). Heart rate (p pregnancy only during the supine position (p pregnancy in all physiological states (p pregnancy in all states (p pregnancy is associated with substantial changes in heart rate variability, reflecting a reduction in parasympathetic tone and an increase in sympathetic activity. QTVI shifted to a less favourable value, reflecting a greater than normal amount of QT variability. QTVI appears to be a useful method for quantifying changes in QT variability relative to RR (or heart rate) variability, being sensitive not only to physiological state but also to gestational age. We support the use of non-invasive markers of cardiac electrical variability to evaluate the risk of arrhythmic events in pregnancy, and we recommend the use of multiple physiological states during the assessment protocol.

  17. Once an Impression Manager, Always an Impression Manager? Antecedents of Honest and Deceptive Impression Management Use and Variability across Multiple Job Interviews.

    Science.gov (United States)

    Roulin, Nicolas; Bourdage, Joshua S

    2017-01-01

    Research has examined the antecedents of applicants' use of impression management (IM) tactics in employment interviews. All existing empirical studies have measured IM in one particular interview. Yet, applicants generally interview multiple times for different positions, and thus have multiple opportunities to engage in IM, before they can secure a job. Similarly, recent theoretical advances in personnel selection and IM research have suggested that applicant behaviors should be considered as dynamic and adaptive in nature. In line with this perspective, the present study is the first to examine the role of individual differences in both applicants' use of IM tactics and the variability in IM use across multiple interviews. It also highlights which honest and deceptive IM tactics remain stable vs. vary in consecutive interviews with different interviewers and organizations. Results suggest that applicants high in Extraversion or core self-evaluations tend to engage in more honest self-promotion but do not adapt their IM approach across interviews. In contrast, applicants who possess more undesirable personality traits (i.e., low on Honesty-Humility and Conscientiousness, but high on Machiavellianism, Narcissism, Psychopathy, or Competitive Worldviews) tend to use more deceptive IM (and especially image creation tactics) and are also more likely to adapt their IM strategy across interviews. Because deceptive IM users can obtain better evaluations from interviewers and the personality profile of those users is often associated with undesirable workplace outcomes, this study provides additional evidence for the claim that deceptive IM (or faking) is a potential threat for organizations.

  18. A comparison on parameter-estimation methods in multiple regression analysis with existence of multicollinearity among independent variables

    Directory of Open Access Journals (Sweden)

    Hukharnsusatrue, A.

    2005-11-01

    Full Text Available The objective of this research is to compare multiple regression coefficients estimating methods with existence of multicollinearity among independent variables. The estimation methods are Ordinary Least Squares method (OLS, Restricted Least Squares method (RLS, Restricted Ridge Regression method (RRR and Restricted Liu method (RL when restrictions are true and restrictions are not true. The study used the Monte Carlo Simulation method. The experiment was repeated 1,000 times under each situation. The analyzed results of the data are demonstrated as follows. CASE 1: The restrictions are true. In all cases, RRR and RL methods have a smaller Average Mean Square Error (AMSE than OLS and RLS method, respectively. RRR method provides the smallest AMSE when the level of correlations is high and also provides the smallest AMSE for all level of correlations and all sample sizes when standard deviation is equal to 5. However, RL method provides the smallest AMSE when the level of correlations is low and middle, except in the case of standard deviation equal to 3, small sample sizes, RRR method provides the smallest AMSE.The AMSE varies with, most to least, respectively, level of correlations, standard deviation and number of independent variables but inversely with to sample size.CASE 2: The restrictions are not true.In all cases, RRR method provides the smallest AMSE, except in the case of standard deviation equal to 1 and error of restrictions equal to 5%, OLS method provides the smallest AMSE when the level of correlations is low or median and there is a large sample size, but the small sample sizes, RL method provides the smallest AMSE. In addition, when error of restrictions is increased, OLS method provides the smallest AMSE for all level, of correlations and all sample sizes, except when the level of correlations is high and sample sizes small. Moreover, the case OLS method provides the smallest AMSE, the most RLS method has a smaller AMSE than

  19. Statistical methods and regression analysis of stratospheric ozone and meteorological variables in Isfahan

    Science.gov (United States)

    Hassanzadeh, S.; Hosseinibalam, F.; Omidvari, M.

    2008-04-01

    Data of seven meteorological variables (relative humidity, wet temperature, dry temperature, maximum temperature, minimum temperature, ground temperature and sun radiation time) and ozone values have been used for statistical analysis. Meteorological variables and ozone values were analyzed using both multiple linear regression and principal component methods. Data for the period 1999-2004 are analyzed jointly using both methods. For all periods, temperature dependent variables were highly correlated, but were all negatively correlated with relative humidity. Multiple regression analysis was used to fit the meteorological variables using the meteorological variables as predictors. A variable selection method based on high loading of varimax rotated principal components was used to obtain subsets of the predictor variables to be included in the linear regression model of the meteorological variables. In 1999, 2001 and 2002 one of the meteorological variables was weakly influenced predominantly by the ozone concentrations. However, the model did not predict that the meteorological variables for the year 2000 were not influenced predominantly by the ozone concentrations that point to variation in sun radiation. This could be due to other factors that were not explicitly considered in this study.

  20. Luciferase assay to study the activity of a cloned promoter DNA fragment.

    Science.gov (United States)

    Solberg, Nina; Krauss, Stefan

    2013-01-01

    Luciferase based assays have become an invaluable tool for the analysis of cloned promoter DNA fragments, both for verifying the ability of a potential promoter fragment to drive the expression of a luciferase reporter gene in various cellular contexts, and for dissecting binding elements in the promoter. Here, we describe the use of the Dual-Luciferase(®) Reporter Assay System created by Promega (Promega Corporation, Wisconsin, USA) to study the cloned 6.7 kilobases (kb) mouse (m) Tcf3 promoter DNA fragment in mouse embryonic derived neural stem cells (NSC). In this system, the expression of the firefly luciferase driven by the cloned mTcf3 promoter DNA fragment (including transcription initiation sites) is correlated with a co-transfected control reporter expressing Renilla luciferase from the herpes simplex virus (HSV) thymidine kinase promoter. Using an internal control reporter allows to normalize the activity of the experimental reporter to the internal control, which minimizes experimental variability.

  1. A homogeneous, high-throughput assay for phosphatidylinositol 5-phosphate 4-kinase with a novel, rapid substrate preparation.

    Directory of Open Access Journals (Sweden)

    Mindy I Davis

    Full Text Available Phosphoinositide kinases regulate diverse cellular functions and are important targets for therapeutic development for diseases, such as diabetes and cancer. Preparation of the lipid substrate is crucial for the development of a robust and miniaturizable lipid kinase assay. Enzymatic assays for phosphoinositide kinases often use lipid substrates prepared from lyophilized lipid preparations by sonication, which result in variability in the liposome size from preparation to preparation. Herein, we report a homogeneous 1536-well luciferase-coupled bioluminescence assay for PI5P4Kα. The substrate preparation is novel and allows the rapid production of a DMSO-containing substrate solution without the need for lengthy liposome preparation protocols, thus enabling the scale-up of this traditionally difficult type of assay. The Z'-factor value was greater than 0.7 for the PI5P4Kα assay, indicating its suitability for high-throughput screening applications. Tyrphostin AG-82 had been identified as an inhibitor of PI5P4Kα by assessing the degree of phospho transfer of γ-(32P-ATP to PI5P; its inhibitory activity against PI5P4Kα was confirmed in the present miniaturized assay. From a pilot screen of a library of bioactive compounds, another tyrphostin, I-OMe tyrphostin AG-538 (I-OMe-AG-538, was identified as an ATP-competitive inhibitor of PI5P4Kα with an IC(50 of 1 µM, affirming the suitability of the assay for inhibitor discovery campaigns. This homogeneous assay may apply to other lipid kinases and should help in the identification of leads for this class of enzymes by enabling high-throughput screening efforts.

  2. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  3. Multiple Meixner polynomials and non-Hermitian oscillator Hamiltonians

    OpenAIRE

    Ndayiragije, François; Van Assche, Walter

    2013-01-01

    Multiple Meixner polynomials are polynomials in one variable which satisfy orthogonality relations with respect to $r>1$ different negative binomial distributions (Pascal distributions). There are two kinds of multiple Meixner polynomials, depending on the selection of the parameters in the negative binomial distribution. We recall their definition and some formulas and give generating functions and explicit expressions for the coefficients in the nearest neighbor recurrence relation. Followi...

  4. Multiple Off-Ice Performance Variables Predict On-Ice Skating Performance in Male and Female Division III Ice Hockey Players.

    Science.gov (United States)

    Janot, Jeffrey M; Beltz, Nicholas M; Dalleck, Lance D

    2015-09-01

    The purpose of this study was to determine if off-ice performance variables could predict on-ice skating performance in Division III collegiate hockey players. Both men (n = 15) and women (n = 11) hockey players (age = 20.5 ± 1.4 years) participated in the study. The skating tests were agility cornering S-turn, 6.10 m acceleration, 44.80 m speed, modified repeat skate, and 15.20 m full speed. Off-ice variables assessed were years of playing experience, height, weight and percent body fat and off-ice performance variables included vertical jump (VJ), 40-yd dash (36.58m), 1-RM squat, pro-agility, Wingate peak power and peak power percentage drop (% drop), and 1.5 mile (2.4km) run. Results indicated that 40-yd dash (36.58m), VJ, 1.5 mile (2.4km) run, and % drop were significant predictors of skating performance for repeat skate (slowest, fastest, and average time) and 44.80 m speed time, respectively. Four predictive equations were derived from multiple regression analyses: 1) slowest repeat skate time = 2.362 + (1.68 x 40-yd dash time) + (0.005 x 1.5 mile run), 2) fastest repeat skate time = 9.762 - (0.089 x VJ) - (0.998 x 40-yd dash time), 3) average repeat skate time = 7.770 + (1.041 x 40-yd dash time) - (0.63 x VJ) + (0.003 x 1.5 mile time), and 4) 47.85 m speed test = 7.707 - (0.050 x VJ) - (0.01 x % drop). It was concluded that selected off-ice tests could be used to predict on-ice performance regarding speed and recovery ability in Division III male and female hockey players. Key pointsThe 40-yd dash (36.58m) and vertical jump tests are significant predictors of on-ice skating performance specific to speed.In addition to 40-yd dash and vertical jump, the 1.5 mile (2.4km) run for time and percent power drop from the Wingate anaerobic power test were also significant predictors of skating performance that incorporates the aspect of recovery from skating activity.Due to the specificity of selected off-ice variables as predictors of on-ice performance, coaches can

  5. Improved assay for thymine base damage in E. coli using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Claycamp, H.G.

    1985-01-01

    A simple high performance liquid chromatography (HPLC) technique has been established for the simultaneous assay of thymine and thymidine radiation damage products. The HPLC procedure uses an isocratic mobile phase of 4% acetonitrile in 0.2 M ammonium dihydrogen phosphate (pH 5.0), a reversed-phase octadecylsilicate (5 micro-spherical packing) 0.45 x 25 cm column, and a variable wavelength UV detector. This procedure affords much better resolution than other published procedures that use 10 micron columns or separate assays for bases and nucleosides. For example, irradiation of 5 x 10 -3 M thymidine solutions have been performed to calibrate the system for base damage assays in E. coli. This yields up to 15 resolvable residues within 20 minutes. Sensitivity of the system (at 2210 nm) for 5,6- dihydrothymine (DHT) is about 10 -10 moles. Preliminary results show that this translates to about 0.4 DHT residues per 10 6 daltons of E. coli DNA. This is comparable to the sensitivities of monoclonal assays to thymine damage products that have recently been reported by others. Since it is feasible that the sensitivity of this system can be improved by 2-3 times, this HPLC technique should provide a simple and rapid means of detecting E. coli base damage release and base damage in nucleoside hydrolysates of DNA

  6. Nano-immunosafety: issues in assay validation

    International Nuclear Information System (INIS)

    Boraschi, Diana; Italiani, Paola; Oostingh, Gertie J; Duschl, Albert; Casals, Eudald; Puntes, Victor F; Nelissen, Inge

    2011-01-01

    Assessing the safety of engineered nanomaterials for human health must include a thorough evaluation of their effects on the immune system, which is responsible for defending the integrity of our body from damage and disease. An array of robust and representative assays should be set up and validated, which could be predictive of the effects of nanomaterials on immune responses. In a trans-European collaborative work, in vitro assays have been developed to this end. In vitro tests have been preferred for their suitability to standardisation and easier applicability. Adapting classical assays to testing the immunotoxicological effects of nanoparticulate materials has raised a series of issues that needed to be appropriately addressed in order to ensure reliability of results. Besides the exquisitely immunological problem of selecting representative endpoints predictive of the risk of developing disease, assay results turned out to be significantly biased by artefactual interference of the nanomaterials or contaminating agents with the assay protocol. Having addressed such problems, a series of robust and representative assays have been developed that describe the effects of engineered nanoparticles on professional and non-professional human defence cells. Two of such assays are described here, one based on primary human monocytes and the other employing human lung epithelial cells transfected with a reporter gene.

  7. Long-Term Efficacy and Patterns of Failure After Accelerated Partial Breast Irradiation: A Molecular Assay-Based Clonality Evaluation

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Antonucci, J. Vito; Wallace, Michelle R.N.; Gilbert, Samuel; Goldstein, Neal S.; Kestin, Larry; Chen, Peter; Kunzman, Jonathan; Boike, Thomas; Benitez, Pamela; Martinez, Alvaro

    2007-01-01

    Purpose: To determine the long-term efficacy and cosmetic results of accelerated partial breast irradiation (APBI) by reviewing our institution's experience. Methods and Materials: A total of 199 patients with early-stage breast cancer were treated prospectively with adjuvant APBI after lumpectomy using interstitial brachytherapy. All patients had negative margins, 82% had Stage I disease, median tumor size was 1.1 cm, and 12% had positive lymph nodes. The median follow-up for surviving patients was 8.6 years. Fifty-three patients (27%) have been followed for ≥10 years. Results: Six ipsilateral breast tumor recurrences (IBTRs) were observed, for a 5-year and 10-year actuarial rate of 1.6% and 3.8%, respectively. A total of three regional nodal failures were observed, for a 10-year actuarial rate of 1.6%. Five contralateral breast cancers developed, for a 5- and 10-year actuarial rate of 2.2% and 5.2%, respectively. The type of IBTR (clonally related vs. clonally distinct) was analyzed using a polymerase chain reaction-based loss of heterozygosity assay. Eighty-three percent of IBTRs (n = 5) were classified as clonally related. Multiple clinical, pathologic, and treatment-related factors were analyzed for an association with the development of an IBTR, regional nodal failure, or contralateral breast cancer. On multivariate analysis, no variable was associated with any of these events. Cosmetic results were rated as excellent/good in 99% of patients. Conclusions: Long-term results with APBI using interstitial brachytherapy continue to demonstrate excellent long-term local and regional control rates and cosmetic results. According to a polymerase chain reaction-based loss of heterozygosity assay, 83% of recurrences were classified as clonally related

  8. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  9. Multiple-locus variant-repeat assay (MLVA) is a useful tool for molecular epidemiologic analysis of Streptococcus agalactiae strains causing bovine mastitis.

    Science.gov (United States)

    Radtke, Andreas; Bruheim, Torkjel; Afset, Jan Egil; Bergh, Kåre

    2012-06-15

    Group B streptococci (GBS) were considered a major cause of mastitis in cattle until preventive measures succeeded in controlling the disease in the 1970s and 1980s. During the last 5-6 years an increasing number of cases have been observed in some Scandinavian countries. A total of 187 GBS isolates from mastitis cases were collected from 119 animals in 34 Norwegian farms in the period from April 2007 to November 2010. 133 (71%) of the isolates were from farms with automated milking systems. The strains underwent typing of capsular polysaccharides (CPS) and surface proteins, and were analyzed by multi-locus variable repeat assay (MLVA) to investigate the epidemiological relationship of strains within and between farms. The GBS strains were differentiated into 12 types by CPS and surface protein analysis, with CPS types V (54%) and IV (34%) predominating. MLVA was superior to CPS and protein typing for strain differentiation, resolving the 187 strains into 37 types. In 29 of 34 farms all GBS strains had identical MLVA profiles specific for each farm. However, in one farm represented with 48 isolates, four MLVA variants with differences in one repeat locus were observed during the almost 3-year long collection period. Similar variations were observed at four other farms. This might reflect the stability of repeat loci under in vivo conditions. Farms with automated milking systems were overrepresented in this material. In conclusion, the five-loci MLVA allowed rapid high-resolution genotyping of the bovine GBS strains within and between farms. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Multiple-locus variable-number tandem repeat analysis of Leptospira interrogans and Leptospira borgpetersenii isolated from small feral and wild mammals in East Asia.

    Science.gov (United States)

    Koizumi, Nobuo; Izumiya, Hidemasa; Mu, Jung-Jung; Arent, Zbigniew; Okano, Shou; Nakajima, Chie; Suzuki, Yasuhiko; Mizutani Muto, Maki; Tanikawa, Tsutomu; Taylor, Kyle R; Komatsu, Noriyuki; Yoshimatsu, Kumiko; Thi Thu Ha, Hoang; Ohnishi, Makoto

    2015-12-01

    Leptospira spp. are the causative agents of a worldwide zoonosis, leptospirosis, maintained by various mammals. Each Leptospira serovar is frequently associated with a particular maintenance host, and recently, Leptospira genotype-host association has also been suggested to limit serovars to restricted areas. We investigated the molecular characteristics of L. interrogans and L. borgpetersenii which were isolated from small feral and wild animals in four East Asian states using multiple-locus variable-number tandem repeat analysis (MLVA). MLVA using 11 loci was performed on 110 L. interrogans serogroups from Japan (79 strains of 5 serogroups from 3 animal species), Philippines (21; 3; 2), Taiwan (7; 2; 3), and Vietnam (3; 1; 1). A MLVA method using 4 loci for L. borgpetersenii was established and performed on 52 isolates from Japan (26; 3; 7), Philippines (13; 1; 2), and Taiwan (13; 1; 3). In L. interrogans, serogroups Autumnalis and Hebdomadis appeared more genetically diverse than serogroups Bataviae, Grippotyphosa, Icterohaemorrhagiae, Pomona, or Pyrogenes. The former serogroup strains with the exception of one Hebdomadis strain were isolated from Apodemus speciosus while all the latter serogroup strains with the exception of Grippotyphosa were isolated from Rattus norvegicus. L. borgpetersenii was isolated from at least 11 animal species while L. interrogans was isolated from five species, which might suggest a wider host range for L. borgpetersenii. Broad host preference in a single genotype was also observed, which colonized not only different species of the same genera but also multiple animal genera. This study demonstrates that there may be variability in the range of genetic diversity among different Leptospira serogroups, which may be attributed to maintenance host animals and environmental factors. Copyright © 2015. Published by Elsevier B.V.

  11. Heterogeneity in the multiple myeloma tumor clone

    NARCIS (Netherlands)

    Guikema, JEJ; Hovenga, S; Vellenga, E; Bos, NA

    Multiple Myeloma ( MM) is a plasma cell malignancy which is characterized by a very heterogeneous disease outcome. Heterogeneity in plasma cell characteristics, including morphology, maturation status, immunophenotype and genetic abnormalities partly account for the variable disease outcome.

  12. Limit theorems for multi-indexed sums of random variables

    CERN Document Server

    Klesov, Oleg

    2014-01-01

    Presenting the first unified treatment of limit theorems for multiple sums of independent random variables, this volume fills an important gap in the field. Several new results are introduced, even in the classical setting, as well as some new approaches that are simpler than those already established in the literature. In particular, new proofs of the strong law of large numbers and the Hajek-Renyi inequality are detailed. Applications of the described theory include Gibbs fields, spin glasses, polymer models, image analysis and random shapes. Limit theorems form the backbone of probability theory and statistical theory alike. The theory of multiple sums of random variables is a direct generalization of the classical study of limit theorems, whose importance and wide application in science is unquestionable. However, to date, the subject of multiple sums has only been treated in journals. The results described in this book will be of interest to advanced undergraduates, graduate students and researchers who ...

  13. Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.

    Science.gov (United States)

    Boroumand, Mohammadali; Goodarzynejad, Hamidreza

    2010-01-01

    Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation

  14. Multiple regression for physiological data analysis: the problem of multicollinearity.

    Science.gov (United States)

    Slinker, B K; Glantz, S A

    1985-07-01

    Multiple linear regression, in which several predictor variables are related to a response variable, is a powerful statistical tool for gaining quantitative insight into complex in vivo physiological systems. For these insights to be correct, all predictor variables must be uncorrelated. However, in many physiological experiments the predictor variables cannot be precisely controlled and thus change in parallel (i.e., they are highly correlated). There is a redundancy of information about the response, a situation called multicollinearity, that leads to numerical problems in estimating the parameters in regression equations; the parameters are often of incorrect magnitude or sign or have large standard errors. Although multicollinearity can be avoided with good experimental design, not all interesting physiological questions can be studied without encountering multicollinearity. In these cases various ad hoc procedures have been proposed to mitigate multicollinearity. Although many of these procedures are controversial, they can be helpful in applying multiple linear regression to some physiological problems.

  15. Predictor variable resolution governs modeled soil types

    Science.gov (United States)

    Soil mapping identifies different soil types by compressing a unique suite of spatial patterns and processes across multiple spatial scales. It can be quite difficult to quantify spatial patterns of soil properties with remotely sensed predictor variables. More specifically, matching the right scale...

  16. Development of a multiple-marker polymerase chain reaction assay for detection of metastatic melanoma in lymph node aspirates of dogs.

    Science.gov (United States)

    Catchpole, Brian; Gould, Sara M; Kellett-Gregory, Lindsay M; Dobson, Jane M

    2003-05-01

    To develop a reverse transcriptase-polymerase chain reaction (RT-PCR) assay to detect canine melanoma-associated antigens (MAAs) and to use this technique to screen aspirates of lymph nodes (LNs) for evidence of metastatic spread of oral malignant melanoma. 7 dogs with oral malignant melanoma and 4 dogs with multicentric lymphosarcoma. We prepared cDNA from melanoma tumor biopsies and fine-needle aspirates obtained from submandibular LNs of dogs with oral malignant melanoma or multicentric lymphosarcoma. The RT-PCR assay was performed by use of tyrosinase, Melan-A, gp100, tyrosinase-related protein 2 (TRP-2), or melanoma antigen-encoding gene B (MAGE-B)-specific primers. We detected MAGE-B mRNA in canine testicular tissue but not in melanoma biopsy specimens. Tyrosinase, Melan-A, gp100, and TRP-2 mRNAs were detected in tumor biopsy specimens and in 2 of 5 LN aspirates from dogs with melanoma, suggesting metastatic spread in those 2 dogs. We did not detect MAAs in LN aspirates obtained from dogs with multicentric lymphosarcoma. Sequencing of canine Melan-A and gp100 PCR products confirmed the specificity of the assay for these genes. Clinical staging of dogs with oral malignant melanoma is useful to assist in designing appropriate treatments. However, results of histologic examination of LN biopsy specimens can be inconclusive and, in humans, can underestimate the number of patients with metastatic disease. Molecular staging of melanomas in dogs can be achieved by screening LN aspirates for MAA mRNA, and this can be performed in combination with cytologic examination to aid in detection of metastatic disease.

  17. A data-driven multiplicative fault diagnosis approach for automation processes.

    Science.gov (United States)

    Hao, Haiyang; Zhang, Kai; Ding, Steven X; Chen, Zhiwen; Lei, Yaguo

    2014-09-01

    This paper presents a new data-driven method for diagnosing multiplicative key performance degradation in automation processes. Different from the well-established additive fault diagnosis approaches, the proposed method aims at identifying those low-level components which increase the variability of process variables and cause performance degradation. Based on process data, features of multiplicative fault are extracted. To identify the root cause, the impact of fault on each process variable is evaluated in the sense of contribution to performance degradation. Then, a numerical example is used to illustrate the functionalities of the method and Monte-Carlo simulation is performed to demonstrate the effectiveness from the statistical viewpoint. Finally, to show the practical applicability, a case study on the Tennessee Eastman process is presented. Copyright © 2013. Published by Elsevier Ltd.

  18. Spectrophotometric Enzyme Assays for High-Throughput Screening

    Directory of Open Access Journals (Sweden)

    Jean-Louis Reymond

    2004-01-01

    Full Text Available This paper reviews high-throughput screening enzyme assays developed in our laboratory over the last ten years. These enzyme assays were initially developed for the purpose of discovering catalytic antibodies by screening cell culture supernatants, but have proved generally useful for testing enzyme activities. Examples include TLC-based screening using acridone-labeled substrates, fluorogenic assays based on the β-elimination of umbelliferone or nitrophenol, and indirect assays such as the back-titration method with adrenaline and the copper-calcein fluorescence assay for aminoacids.

  19. Radioenzymatic assay of DOPA (3,4-dihydroxyphenylalanine)

    International Nuclear Information System (INIS)

    Johnson, G.A.; Gren, J.M.; Kupiecki, R.

    1978-01-01

    We modified the single-isotope radioenzymatic assay for catecholamines [Life Sci. 21, 625(1977)] to assay 3,4-dihydroxyphenylalanine (DOPA). DOPA decarboxylase is used to convert DOPA to dopamine, which concurrently is converted to [ 3 H]-3-O-methyldopamine in the presence of catechol-O-methyltransferase and [methyl- 3 H]-S-adenosylmethionine and assayed radioenzymatically. For assay of plasma DOPA, 50 μl of untreated plasma is added directly into the incubation mixture. A duplicate mixture containing an internal standard requires a second 50-μl aliquot of plasma. Because the assay measures both DOPA and endogenous dopamine, two additional aliquots of plasma must be assayed for dopamine in the absence of the decarboxylase by the differential assay; DOPA is estimated by difference. The assay is sensitive to 25 pg (500 ng/liter of plasma). Analysis of DOPA (DOPA plus dopamine) and the concurrent differential assay of catecholamines in at least 10 samples can be done in a single working day. Plasma DOPA concentrations for 42 normotensive adults were 1430 +- 19 ng/liter (mean +- SEM). In contrast, dopamine concentrations for these same subjects averaged 23 +- 20 ng/liter. Values for the 24 women subjects (1510 +- 62 ng/liter) significantly (P = 0.04) exceeded those for the men

  20. RAS - Screens & Assays - Drug Discovery

    Science.gov (United States)

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  1. The fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Lindhagen, Elin; Nygren, Peter; Larsson, Rolf

    2008-01-01

    The fluorometric microculture cytotoxicity assay (FMCA) is a nonclonogenic microplate-based cell viability assay used for measurement of the cytotoxic and/or cytostatic effect of different compounds in vitro. The assay is based on hydrolysis of the probe, fluorescein diacetate (FDA) by esterases in cells with intact plasma membranes. The assay is available as both a semiautomated 96-well plate setup and a 384-well plate version fully adaptable to robotics. Experimental plates are prepared with a small amount of drug solution and can be stored frozen. Cells are seeded on the plates and cell viability is evaluated after 72 h. The protocol described here is applicable both for cell lines and freshly prepared tumor cells from patients and is suitable both for screening in drug development and as a basis for a predictive test for individualization of anticancer drug therapy.

  2. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  3. Heterogeneity in the multiple myeloma tumor clone

    NARCIS (Netherlands)

    Guikema, Jeroen E. J.; Hovenga, Sjoerd; Vellenga, Edo; Bos, Nicolaas A.

    2004-01-01

    Multiple Myeloma (MM) is a plasma cell malignancy which is characterized by a very heterogeneous disease outcome. Heterogeneity in plasma cell characteristics, including morphology, maturation status, immunophenotype and genetic abnormalities partly account for the variable disease outcome. Although

  4. Phenotypic variability in unicellular organisms: from calcium signalling to social behaviour.

    Science.gov (United States)

    Vogel, David; Nicolis, Stamatios C; Perez-Escudero, Alfonso; Nanjundiah, Vidyanand; Sumpter, David J T; Dussutour, Audrey

    2015-11-22

    Historically, research has focused on the mean and often neglected the variance. However, variability in nature is observable at all scales: among cells within an individual, among individuals within a population and among populations within a species. A fundamental quest in biology now is to find the mechanisms that underlie variability. Here, we investigated behavioural variability in a unique unicellular organism, Physarum polycephalum. We combined experiments and models to show that variability in cell signalling contributes to major differences in behaviour underpinning some aspects of social interactions. First, following thousands of cells under various contexts, we identified distinct behavioural phenotypes: 'slow-regular-social', 'fast-regular-social' and 'fast-irregular-asocial'. Second, coupling chemical analysis and behavioural assays we found that calcium signalling is responsible for these behavioural phenotypes. Finally, we show that differences in signalling and behaviour led to alternative social strategies. Our results have considerable implications for our understanding of the emergence of variability in living organisms. © 2015 The Author(s).

  5. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  6. Time-resolved immunofluorometric assay of serum ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yao [China Inst. of Atomic Energy, Beijing (China)

    2007-06-15

    This assay is a solid phase, two-site fluoroimmunometric assay based on the direct sandwish technique. Standards or samples containing ferritin are first reacted with immobilized anti-ferritin antibodies. Then the europium-lablled antibodies are reacted with the bound antigen. The range of this assay is 2-1000 ng/mL. The analytical sentivity is better than 0.05 ng/mL. The intra-assay variation and inter-assay variation are both below 5%; This kit was compared with Wallac DELFIA kit. The correlation is r=0.96. (authors)

  7. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  8. Uncertainty Quantification Reveals the Importance of Data Variability and Experimental Design Considerations for in Silico Proarrhythmia Risk Assessment

    Directory of Open Access Journals (Sweden)

    Kelly C. Chang

    2017-11-01

    Full Text Available The Comprehensive in vitro Proarrhythmia Assay (CiPA is a global initiative intended to improve drug proarrhythmia risk assessment using a new paradigm of mechanistic assays. Under the CiPA paradigm, the relative risk of drug-induced Torsade de Pointes (TdP is assessed using an in silico model of the human ventricular action potential (AP that integrates in vitro pharmacology data from multiple ion channels. Thus, modeling predictions of cardiac risk liability will depend critically on the variability in pharmacology data, and uncertainty quantification (UQ must comprise an essential component of the in silico assay. This study explores UQ methods that may be incorporated into the CiPA framework. Recently, we proposed a promising in silico TdP risk metric (qNet, which is derived from AP simulations and allows separation of a set of CiPA training compounds into Low, Intermediate, and High TdP risk categories. The purpose of this study was to use UQ to evaluate the robustness of TdP risk separation by qNet. Uncertainty in the model parameters used to describe drug binding and ionic current block was estimated using the non-parametric bootstrap method and a Bayesian inference approach. Uncertainty was then propagated through AP simulations to quantify uncertainty in qNet for each drug. UQ revealed lower uncertainty and more accurate TdP risk stratification by qNet when simulations were run at concentrations below 5× the maximum therapeutic exposure (Cmax. However, when drug effects were extrapolated above 10× Cmax, UQ showed that qNet could no longer clearly separate drugs by TdP risk. This was because for most of the pharmacology data, the amount of current block measured was <60%, preventing reliable estimation of IC50-values. The results of this study demonstrate that the accuracy of TdP risk prediction depends both on the intrinsic variability in ion channel pharmacology data as well as on experimental design considerations that preclude an

  9. Brain-derived neurotrophic factor levels under chronic natalizumab treatment in multiple sclerosis. A preliminary report.

    Science.gov (United States)

    Văcăraş, Vitalie; Major, Zoltán Zsigmond; Buzoianu, Anca Dana

    Our main purpose was to investigate if the chronic treatment with the disease-modifying drug natalizumab shows quantifiable effect on BDNF levels in multiple sclerosis patients. BDNF plasma concentration was evaluated using enzyme-linked immunosorbent assay in healthy individuals, not treated multiple sclerosis patients and patients treated with natalizumab. Multiple sclerosis patients have a significantly lower amount of peripheral BDNF than healthy individuals. Patients treated with natalizumab have significantly higher BDNF levels than not treated patients. Chronic natalizumab treatment is associated with significantly increased plasma BDNF concentration in multiple sclerosis. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  10. Investigation of the effect of kaolin and tissue factor-activated citrated whole blood, on clot forming variables, as evaluated by thromboelastograph

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Bochsen, L.; Andersen, S.

    2008-01-01

    ), and maximum clot strength (amplitude [MA]) were evaluated, together with day-to-day variation, the coefficient of variance (CV%), and the effect of citrate storage time. RESULTS: Clot formation variables were equally affected by TF 1:17,000 and kaolin activation, whereas R was significantly longer when TF 1......:42,500 was used. The CV for the different variables varied from 3 to 13 percent with no significant differences between assays. Storage of citrated WB significantly affected the TEG variables in a hypercoagulable direction. Only the R, however, was significantly affected (12%) when samples rested for 0 and 30...... minutes were evaluated with kaolin as the activator. CONCLUSION: The TEG assays evaluated were reproducible and present with an acceptable CV% for routine clinical practice. Kaolin and TF 1:17,000 equally affected the clot formation variables. Storage of WB for up to 30 minutes in citrate did not, except...

  11. Development of a novel concept for performing multiple assays on clinical samples using fluidic device

    DEFF Research Database (Denmark)

    Søe, Martin Jensen

    RNA-130a sammenlignet med konventionelle teknikker, hvor der benyttes prober af DNA og LNA. Desuden kunne multiple miRNAer detekteres ved brug af sekventielle inkuberinger af TSA reagens. Dette tillod detektion af to miRNA og et protein på samme vævssnit. Den anden model involverede design og konstruktion...

  12. Multiple causes of nonstationarity in the Weihe annual low-flow series

    Science.gov (United States)

    Xiong, Bin; Xiong, Lihua; Chen, Jie; Xu, Chong-Yu; Li, Lingqi

    2018-02-01

    Under the background of global climate change and local anthropogenic activities, multiple driving forces have introduced various nonstationary components into low-flow series. This has led to a high demand on low-flow frequency analysis that considers nonstationary conditions for modeling. In this study, through a nonstationary frequency analysis framework with the generalized linear model (GLM) to consider time-varying distribution parameters, the multiple explanatory variables were incorporated to explain the variation in low-flow distribution parameters. These variables are comprised of the three indices of human activities (HAs; i.e., population, POP; irrigation area, IAR; and gross domestic product, GDP) and the eight measuring indices of the climate and catchment conditions (i.e., total precipitation P, mean frequency of precipitation events λ, temperature T, potential evapotranspiration (EP), climate aridity index AIEP, base-flow index (BFI), recession constant K and the recession-related aridity index AIK). This framework was applied to model the annual minimum flow series of both Huaxian and Xianyang gauging stations in the Weihe River, China (also known as the Wei He River). The results from stepwise regression for the optimal explanatory variables show that the variables related to irrigation, recession, temperature and precipitation play an important role in modeling. Specifically, analysis of annual minimum 30-day flow in Huaxian shows that the nonstationary distribution model with any one of all explanatory variables is better than the one without explanatory variables, the nonstationary gamma distribution model with four optimal variables is the best model and AIK is of the highest relative importance among these four variables, followed by IAR, BFI and AIEP. We conclude that the incorporation of multiple indices related to low-flow generation permits tracing various driving forces. The established link in nonstationary analysis will be beneficial

  13. Development of an ultrasensitive PCR assay for polycyclic musk determination in fish.

    Science.gov (United States)

    Zhang, Xiaohan; Zhuang, Huisheng

    2018-05-01

    Polycyclic musks (PCMs) in the aquatic environment and organisms have become an emerging environmental issue because of their potential risk. The most used method for polycyclic musk determination is gas chromatography-mass spectrometry (GC-MS) with different sample extractions, which are somewhat expensive to operate, complex and laborious. In this study, a novel and ultrasensitive real-time polymerase chain reaction (PCR) assay with multiple signal amplification of carboxylic-DNA by gold nanoparticle-polyamidoamine conjugation (Au-PAMAM) was developed for determining polycyclic musks in fish. Hapten and immunogen were specially prepared. Polyclonal antibodies were produced based on the optimal immunisation, and the antibodies were characterised. Due to PAMAM's unique nanostructure of numerous functional amino groups, polyclonal antibody and carboxylic-DNA were immobilised by Au-PAMAM conjugation to develop the antibody-Au-PAMAM-DNA probes, which were used as a signal DNA amplifier in the PCR system. Compared with real-time immuno-PCR, this biological probe-amplified immuno-PCR (BPAI-PCR) assay had higher sensitivity due to the probes' higher ratio of signal DNA. Finally, the BPAI-PCR assay was applied to analyse AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene,Tonalide) concentrations in fish samples in the range from 1 pg/L to 10 ng/L, giving an of LOD 0.61 pg/L. In general, due to the specificity of the antibody and novel nanoprobe design, this BPAI-PCR assay provided a potential way for trace analysis of AHTN in the aquatic organisms. The high concentrations of AHTN found in cultivated fish should encourage further toxicological studies.

  14. Assessing sediment contamination using six toxicity assays

    Directory of Open Access Journals (Sweden)

    Allen G. BURTON Jr.

    2001-08-01

    Full Text Available An evaluation of sediment toxicity at Lake Orta, Italy was conducted to compare a toxicity test battery of 6 assays and to evaluate the extent of sediment contamination at various sediment depths. Lake Orta received excessive loadings of copper and ammonia during the 1900’s until a large remediation effort was conducted in 1989-90 using lime addition. Since that time, the lake has shown signs of a steady recovery of biological communities. The study results showed acute toxicity still exists in sediments at a depth of 5 cm and greater. Assays that detected the highest levels of toxicity were two whole sediment exposures (7 d using Hyalella azteca and Ceriodaphnia dubia. The MicrotoxR assay using pore water was the third most sensitive assay. The Thamnotox, Rototox, Microtox solid phase, and Seed Germination-Root Elongation (pore and solid phase assays showed occasional to no toxicity. Based on similarity of responses and assay sensitivity, the two most useful assays were the C. dubia (or H. azteca and Microtox pore water. These assays were effective at describing sediment toxicity in a weight-of-evidence approach.

  15. Optimization of a colorimetric assay for glycosylated human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Bohney, J.P.; Feldhoff, R.C.

    1986-05-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100/sup 0/C. A NaBH/sub 4/ reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with (/sup 3/H)glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation.

  16. Statistical signal processing and artificial intelligence applications in the nondestructive assay of U/Pu bearing materials

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Forsmann, J.H.

    1997-01-01

    Over the years a number of techniques have been developed to determine the quantity and distribution of radiative isotopes contained in given assay samples through the measurement and analysis of penetrating characteristic radiations. An active technique of particular utility when assaying samples containing very small quantities of fissionable material or when high gamma ray backgrounds are encountered is the delayed neutron nondestructive assay (DN-NDA) technique. Typically, analysis of the delayed neutron signal involves relating the gross delayed neutron count observed following neutron irradiation of an assay sample to total fissionable material present via a linear calibration curve. In this way, the technique is capable of yielding the mass of a single dominant fissionable isotope or the total fissionable mass contained in a sample. Using this approach the only way to determine the mass of individual fissionable isotopes contained in a sample is to correlate total fissionable mass to individual isotopics via calculations or other means, yielding an indirect measure of isotopics. However, there is isotope specific information in the temporal delayed neutron signal due to differences in the delayed neutron precursor yields resulting from the fissioning of different isotopes. The authors present the results of an analysis to evaluate the feasibility of using Kalman filters and genetic algorithms to determine multiple specific fissionable isotopic masses contained in an assay sample from a cumulative delayed neutron signal measured following neutron irradiation of the sample

  17. Correlation of the microculture-kinetic drug-induced apoptosis assay with patient outcomes in initial treatment of adult acute myelocytic leukemia.

    Science.gov (United States)

    Strickland, Stephen A; Raptis, Anastasios; Hallquist, Allan; Rutledge, James; Chernick, Michael; Perree, Mathieu; Talbott, Mahsa S; Presant, Cary A

    2013-03-01

    Overall survival (OS) with acute myeloid leukemia (AML) remains poor. Determining prognostic factors will help in selecting patients for appropriate treatments. Our aim was to determine whether the level of drug-induced apoptosis (chemosensitivity) demonstrated by the microculture-kinetic drug-induced apoptosis (MiCK) assay significantly predicted outcomes after standard AML induction therapy. A total of 109 patients with untreated AML had blood and/or bone marrow aspirate samples analyzed for anthracycline-induced apoptosis using the MiCK assay. The amount of apoptosis observed over 48 h was determined and expressed as kinetic units of apoptosis (KU). Complete remission (CR) was significantly higher (72%) in patients with high idarubicin-induced apoptosis >3 KU compared to patients with apoptosis ≤ 3 KU (p = 0.01). Multivariate analysis showed the only significant variables to be idarubicin-induced apoptosis and karyotype. Median overall survival of patients with idarubicin-induced apoptosis >3 KU was 16.1 months compared to 4.5 months in patients with apoptosis ≤ 3 KU (p = 0.004). Multivariate analysis showed the only significant variable to be idarubicin-induced apoptosis. Chemotherapy-induced apoptosis measured by the MiCK assay demonstrated significant correlation with outcomes and appears predictive of complete remission and overall survival for patients receiving standard induction chemotherapy.

  18. Multiple-locus variable-number tandem repeat analysis for molecular typing of Aspergillus fumigatus

    Directory of Open Access Journals (Sweden)

    Chermette René

    2010-12-01

    Full Text Available Abstract Background Multiple-locus variable-number tandem repeat (VNTR analysis (MLVA is a prominent subtyping method to resolve closely related microbial isolates to provide information for establishing genetic patterns among isolates and to investigate disease outbreaks. The usefulness of MLVA was recently demonstrated for the avian major pathogen Chlamydophila psittaci. In the present study, we developed a similar method for another pathogen of birds: the filamentous fungus Aspergillus fumigatus. Results We selected 10 VNTR markers located on 4 different chromosomes (1, 5, 6 and 8 of A. fumigatus. These markers were tested with 57 unrelated isolates from different hosts or their environment (53 isolates from avian species in France, China or Morocco, 3 isolates from humans collected at CHU Henri Mondor hospital in France and the reference strain CBS 144.89. The Simpson index for individual markers ranged from 0.5771 to 0.8530. A combined loci index calculated with all the markers yielded an index of 0.9994. In a second step, the panel of 10 markers was used in different epidemiological situations and tested on 277 isolates, including 62 isolates from birds in Guangxi province in China, 95 isolates collected in two duck farms in France and 120 environmental isolates from a turkey hatchery in France. A database was created with the results of the present study http://minisatellites.u-psud.fr/MLVAnet/. Three major clusters of isolates were defined by using the graphing algorithm termed Minimum Spanning Tree (MST. The first cluster comprised most of the avian isolates collected in the two duck farms in France, the second cluster comprised most of the avian isolates collected in poultry farms in China and the third one comprised most of the isolates collected in the turkey hatchery in France. Conclusions MLVA displayed excellent discriminatory power. The method showed a good reproducibility. MST analysis revealed an interesting clustering with a

  19. The role of chemometrics in single and sequential extraction assays: a review. Part II. Cluster analysis, multiple linear regression, mixture resolution, experimental design and other techniques.

    Science.gov (United States)

    Giacomino, Agnese; Abollino, Ornella; Malandrino, Mery; Mentasti, Edoardo

    2011-03-04

    Single and sequential extraction procedures are used for studying element mobility and availability in solid matrices, like soils, sediments, sludge, and airborne particulate matter. In the first part of this review we reported an overview on these procedures and described the applications of chemometric uni- and bivariate techniques and of multivariate pattern recognition techniques based on variable reduction to the experimental results obtained. The second part of the review deals with the use of chemometrics not only for the visualization and interpretation of data, but also for the investigation of the effects of experimental conditions on the response, the optimization of their values and the calculation of element fractionation. We will describe the principles of the multivariate chemometric techniques considered, the aims for which they were applied and the key findings obtained. The following topics will be critically addressed: pattern recognition by cluster analysis (CA), linear discriminant analysis (LDA) and other less common techniques; modelling by multiple linear regression (MLR); investigation of spatial distribution of variables by geostatistics; calculation of fractionation patterns by a mixture resolution method (Chemometric Identification of Substrates and Element Distributions, CISED); optimization and characterization of extraction procedures by experimental design; other multivariate techniques less commonly applied. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Large Diversity of Porcine Yersinia enterocolitica 4/O:3 in Eight European Countries Assessed by Multiple-Locus Variable-Number Tandem-Repeat Analysis.

    Science.gov (United States)

    Alakurtti, Sini; Keto-Timonen, Riikka; Virtanen, Sonja; Martínez, Pilar Ortiz; Laukkanen-Ninios, Riikka; Korkeala, Hannu

    2016-06-01

    A total of 253 multiple-locus variable-number tandem-repeat analysis (MLVA) types among 634 isolates were discovered while studying the genetic diversity of porcine Yersinia enterocolitica 4/O:3 isolates from eight different European countries. Six variable-number tandem-repeat (VNTR) loci V2A, V4, V5, V6, V7, and V9 were used to study the isolates from 82 farms in Belgium (n = 93, 7 farms), England (n = 41, 8 farms), Estonia (n = 106, 12 farms), Finland (n = 70, 13 farms), Italy (n = 111, 20 farms), Latvia (n = 66, 3 farms), Russia (n = 60, 10 farms), and Spain (n = 87, 9 farms). Cluster analysis revealed mainly country-specific clusters, and only one MLVA type consisting of two isolates was found from two countries: Russia and Italy. Also, farm-specific clusters were discovered, but same MLVA types could also be found from different farms. Analysis of multiple isolates originating either from the same tonsils (n = 4) or from the same farm, but 6 months apart, revealed both identical and different MLVA types. MLVA showed a very good discriminatory ability with a Simpson's discriminatory index (DI) of 0.989. DIs for VNTR loci V2A, V4, V5, V6, V7, and V9 were 0.916, 0.791, 0.901, 0.877, 0.912, and 0.785, respectively, when studying all isolates together, but variation was evident between isolates originating from different countries. Locus V4 in the Spanish isolates and locus V9 in the Latvian isolates did not differentiate (DI 0.000), and locus V9 in the English isolates showed very low discriminatory power (DI 0.049). The porcine Y. enterocolitica 4/O:3 isolates were diverse, but the variation in DI demonstrates that the well discriminating loci V2A, V5, V6, and V7 should be included in MLVA protocol when maximal discriminatory power is needed.