WorldWideScience

Sample records for multiplanar imaging proof

  1. Multiplanar CT of the spine

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Glenn, W.V. Jr.

    1986-01-01

    This is an illustrated text on computed tomography (CT) of the lumbar spine with an emphasis on the role and value of multiplanar imaging for helping determine diagnoses. The book has adequate discussion of scanning techniques for the different regions, interpretations of various abnormalities, degenerative disk disease, and different diagnoses. There is a 50-page chapter on detailed sectional anatomy of the spine and useful chapters on the postoperative spine and the planning and performing of spinal surgery with CT multiplanar reconstruction. There are comprehensive chapters on spinal tumors and trauma. The final two chapters of the book are devoted to CT image processing using digital networks and CT applications of medical computer graphics

  2. CT triage for lung malignancy: coronal multiplanar reformation versus images in three orthogonal planes.

    Science.gov (United States)

    Kusk, Martin Weber; Karstoft, Jens; Mussmann, Bo Redder

    2015-11-01

    Generation of multiplanar reformation (MPR) images has become automatic on most modern computed tomography (CT) scanners, potentially increasing the workload of the reporting radiologists. It is not always clear if this increases diagnostic performance in all clinical tasks. To assess detection performance using only coronal multiplanar reformations (MPR) when triaging patients for lung malignancies with CT compared to images in three orthogonal planes, and to evaluate performance comparison of novice and experienced readers. Retrospective study of 63 patients with suspicion of lung cancer, scanned on 64-slice multidetector computed tomography (MDCT) with images reconstructed in three planes. Coronal images were presented to four readers, two novice and two experienced. Readers decided whether the patients were suspicious for malignant disease, and indicated their confidence on a five-point scale. Sensitivity and specificity on per-patient basis was calculated with regards to a reference standard of histological diagnosis, and compared with the original report using McNemar's test. Receiver operating characteristic (ROC) curves were plotted to compare the performance of the four readers, using the area under the curve (AUC) as figure of merit. No statistically significant difference of sensitivity and specificity was found for any of the readers when compared to the original reports. ROC analysis yielded AUCs in the range of 0.92-0.93 for all readers with no significant difference. Inter-rater agreement was substantial (kappa = 0.72). Sensitivity and specificity were comparable to diagnosis using images in three planes. No significant difference was found between experienced and novice readers. © The Foundation Acta Radiologica 2014.

  3. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    International Nuclear Information System (INIS)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung; Lee, Jin Yong

    2016-01-01

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length

  4. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung [Dept. of Radiology, Chungbuk National University Hospital, Cheongju (Korea, Republic of); Lee, Jin Yong [Public Health Medical Service, Seoul National University Boramae Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length.

  5. The values of MSCT multi-planar reconstruction in the diagnosis of lumbar spondylolysis

    International Nuclear Information System (INIS)

    Tan Qixuan; Zhu Gangming; Qian Huirong; Zhong Sheng

    2007-01-01

    Objective: To study the reasonable schedule and diagnostic values of MSCT multi-planar reconstruction in patients with lumbar spondylolysis. Methods: Volume scan ranging from T12 to S1 was done in 540 cases suffered from backleg pain without definite trauma. The lumbar disc axial and whole lumbar axial, sagital, coronal images were reconstructed from raw data of MSCT. Results: Of the 540 cases, 54 spondylolysis in isthmus of lumbar pedicle were demonstrated in 29 ones (29/540, 5.37%). 20 cases were accompanied with spondylolisthesis. The sagital multi-planar reconstruction was the best way to reveal the fissures of spondylolysis and accompanying abnormalities. The detectable ratio of fissures in lumbar disc with axial, whole lumbar axial, sagital and coronal multi-planer reconstruction images were 7.41%, 100%, 100% and 51.85% respectively. Conclusions: MSCT sagital multi-planar reconstruction is the best images to reveal the fissures of spondylolysis. It should be taken as routine item in MSCT examination for the patients with lower back pain. (authors)

  6. Multiplanar reformatted CT applications in the lumbar spine

    International Nuclear Information System (INIS)

    Ueda, Takafumi; Kojima, Shinsaburo; Araki, Nobuto; Miyauchi, Sumihiko

    1986-01-01

    Diagnostic value and limitations of multiplanar reformatted CT were evaluated in 55 patients with lumbar diseases. Reformatted images in coronal, sagittal, paraxial, and oblique planes were acquired from the transverse axial images, thereby allowing three-dimensional visualization of lesions in the lumbar spine. Oblique images that were reformmated along the nervous root were useful in visualizing lesions in the root canal, which were not available on either conventional myelography or transverse axial CT. A definitive plane determination is required for reformation of images, taking curvature of the spinal column into account. (Namekawa, K.)

  7. Assessment of intraocular foreign bodies by helical-CT multiplanar imaging

    International Nuclear Information System (INIS)

    Papadopoulos, A.; Fotinos, A.; Maniatis, V.; Kavadias, S.; Michaelides, A.; Avouri, M.; Kalamara, C.; Stringaris, K.

    2001-01-01

    The aim of this study was to examine the effectiveness of helical CT in the assessment of intraocular foreign bodies, evaluating two protocols with different collimation. We performed helical-CT studies in 30 patients. Fifteen patients were examined with 1.5-mm collimation and the other 15 patients with 3.0-mm collimation. All other imaging parameters were identical in both protocols. Multiplanar images were reconstructed. The examinations were reviewed for presence, localization and size of intraocular foreign bodies. We compare our results with the surgical data. We estimate the required examination time. In the first group (collimation 1.5 mm) an intraorbital foreign body was detected in 8 of 15 patients. In 3 of 8 patients an intraocular foreign body (all were metallic) was detected. In the second group (collimation 3.0 mm) an intraorbital foreign body was detected in 9 of 15 patients. In 8 of 9 patients an intraocular foreign body (all were metallic) was detected. Our results were confirmed by surgery in all cases. Examination time was 36 s in the first group and 18 s in the second group. Computed tomography should be considered the imaging modality of choice in the assessment of metallic intraocular foreign bodies and 3.0-mm collimation is optional, because of reduced examination time and radiation exposure. (orig.)

  8. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion

  9. Multidetector CT evaluation of central airways stenoses: Comparison of virtual bronchoscopy, minimal-intensity projection, and multiplanar reformatted images

    Directory of Open Access Journals (Sweden)

    Dinesh K Sundarakumar

    2011-01-01

    Full Text Available Aims: To evaluate the diagnostic utility of virtual bronchoscopy, multiplanar reformatted images, and minimal-intensity projection in assessing airway stenoses. Settings and Design: It was a prospective study involving 150 patients with symptoms of major airway disease. Materials and Methods: Fifty-six patients were selected for analysis based on the detection of major airway lesions on fiber-optic bronchoscopy (FB or routine axial images. Comparisons were made between axial images, virtual bronchoscopy (VB, minimal-intensity projection (minIP, and multiplanar reformatted (MPR images using FB as the gold standard. Lesions were evaluated in terms of degree of airway narrowing, distance from carina, length of the narrowed segment and visualization of airway distal to the lesion. Results: MPR images had the highest degree of agreement with FB (Κ = 0.76 in the depiction of degree of narrowing. minIP had the least degree of agreement with FB (Κ = 0.51 in this regard. The distal visualization was best on MPR images (84.2%, followed by axial images (80.7%, whereas FB could visualize the lesions only in 45.4% of the cases. VB had the best agreement with FB in assessing the segment length (Κ = 0.62. Overall there were no statistically significant differences in the measurement of the distance from the carina in the axial, minIP, and MPR images. MPR images had the highest overall degree of confidence, namely, 70.17% (n = 40. Conclusion: Three-dimensional reconstruction techniques were found to improve lesion evaluation compared with axial images alone. The technique of MPR images was the most useful for lesion evaluation and provided additional information useful for surgical and airway interventions in tracheobronchial stenosis. minIP was useful in the overall depiction of airway anatomy.

  10. Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images

    International Nuclear Information System (INIS)

    Duc, Sylvain R.; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments. (orig.)

  11. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  12. Congenital anomalies of the inferior vena cava: importance of multiplanar imaging methods: an iconographic essay; Anomalias congenitas da veia cava inferior: valor dos metodos multiplanares em seu diagnostico - ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Sergio Lopes; Mendonca, Jose Luiz Furtado de; Freitas, Flavia Mendes Oliveira [Clinica Radiologica Vila Rica, Brasilia, DF (Brazil)] (and others). E-mail: radiolog@uol.com.br

    2006-10-15

    The inferior vena cava is the result of a complex embryologic process which takes place between 6 and 8 weeks of intra-uterine life. Several variations can occur during this process, and a defective embryogenesis of this vessel may lead to the development of anatomic variants. Although many of these variants are asymptomatic, the radiologist should be aware of them and of the potential medico-legal issues involved, especially in cases in which abdominal surgery or hemodynamic procedures are contemplated. In this paper, the major congenital anomalies involving the inferior vena cava are reviewed under the form of a pictorial essay, highlighting the role of the multiplanar imaging methods (volumetric computed tomography and magnetic resonance imaging) in their diagnosis. Keywords: Congenital variations; Inferior vena cava; Renal veins; Computed tomography; Magnetic resonance imaging. author)

  13. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  14. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  15. Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Honda, O; Yanagawa, M; Inoue, A; Kikuyama, A; Yoshida, S; Sumikawa, H; Tobino, K; Koyama, M; Tomiyama, N

    2011-04-01

    We investigated the image quality of multiplanar reconstruction (MPR) using adaptive statistical iterative reconstruction (ASIR). Inflated and fixed lungs were scanned with a garnet detector CT in high-resolution mode (HR mode) or non-high-resolution (HR) mode, and MPR images were then reconstructed. Observers compared 15 MPR images of ASIR (40%) and ASIR (80%) with those of ASIR (0%), and assessed image quality using a visual five-point scale (1, definitely inferior; 5, definitely superior), with particular emphasis on normal pulmonary structures, artefacts, noise and overall image quality. The mean overall image quality scores in HR mode were 3.67 with ASIR (40%) and 4.97 with ASIR (80%). Those in non-HR mode were 3.27 with ASIR (40%) and 3.90 with ASIR (80%). The mean artefact scores in HR mode were 3.13 with ASIR (40%) and 3.63 with ASIR (80%), but those in non-HR mode were 2.87 with ASIR (40%) and 2.53 with ASIR (80%). The mean scores of the other parameters were greater than 3, whereas those in HR mode were higher than those in non-HR mode. There were significant differences between ASIR (40%) and ASIR (80%) in overall image quality (pASIR did not suppress the severe artefacts of contrast medium. In general, MPR image quality with ASIR (80%) was superior to that with ASIR (40%). However, there was an increased incidence of artefacts by ASIR when CT images were obtained in non-HR mode.

  16. Multiplanar reconstructed CT images increased depiction of intracranial hemorrhages in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Langford, Stacey; Panigrahy, Ashok; Narayanan, Srikala; Hwang, Misun; Fitz, Charles; Flom, Lynda; Lee, Vincent Kyu; Zuccoli, Giulio [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Section of Neuroradiology, Pittsburgh, PA (United States)

    2015-12-15

    The benefits of multiplanar reconstructed images (MPR) of unenhanced axial head computed tomography (CT) data have not been established in trauma patients younger than 3 years old, a population in which a reliable history and physical examination may be most difficult. We retrospectively evaluated unenhanced head CTs in pediatric trauma patients to investigate the various benefits of MPR in this age group. A total of 221 unenhanced head CTs performed for any case of head trauma (HT) on children younger than 3 years old were independently reviewed by two radiologists. Studies were reviewed first in the standard axial plane alone and then with the addition of MPR. Reviewers were asked to determine if the MPR affected the ability to make findings of hemorrhage, incidental findings, and artifacts. MPR improved the detection of hemorrhage in 14 cases (6.5 %, p-value < 0.01) and incidental findings in five cases (2.3 %, p-value < 0.05) as well as helped prove artifacts in five cases (2.3 %, p-value < 0.05). Routine use of MPR in HT patients younger than 3 years old has the potential to increase the detection of acute and incidental imaging findings. (orig.)

  17. The usefulness of multiplanar reconstruction images in preoperative t-staging of advanced gastric cancer

    International Nuclear Information System (INIS)

    Koo, Young Baek; Kim, Suk; Lee, Jun Woo; Kim, Soo Jin; Choo, Ki Seok; Lee, Tae Hong; Moon, Tae Yong; Lee, Suk Hong; Jeon, Tae Yong

    2004-01-01

    The purpose of this study was to evaluate the performance of multidetector-row CT (MDCT) in the preoperative T-staging of patients with advanced gastric cancer. A total of 65 patients with an established diagnosis of advanced gastric cancer (T2 or more) were evaluated with MDCT. The protocol of MDCT consisted of high-quality (HQ) mode helical scanning with a slice thickness of 2.5 mm. The axial CT images were reconstructed with a slice thickness of 5 mm. MPR images were reconstructed from the raw axial data with a slice thickness of 5 mm. A comparison between the standard axial and axial MPR images was performed by two radiologists with regard to the evaluation of the tumor location and T-stage. These findings were compared with the pathologic and surgical findings. T-staging of the advanced stomach cancer was correct in 89% (58/65) and 69% (45/65) of the MPR images and axial images, respectively. The MPR images improved the detection rate (5 lesions) of the tumors and increased the accuracy of the T-staging (13 lesions) in comparison with the axial images. The MPR images are of greater diagnostic value for the evaluation of omental seeding (5 lesions: axial images, 9 lesions: MPR images), tumor location and extension. Multiplanar reconstruction (MPR) images provide increased confidence in the location and T-staging of certain cases of advanced gastric cancer, such as those in locations where CT images are susceptible to be affected by the difficulties associated with partial volume averaging. In this study, the MPR images provided more precise information about the tumor location and T-staging than the standard axial images in the preoperative evaluation of advanced gastric cancer

  18. Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukushima, Hiromichi; Takada, Akira; Mori, Yoshimi; Suzuki, Kojiro; Sawaki, Akiko; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo; Itoh, Shigeki; Ikeda, Mitsuru

    2006-01-01

    The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone. (orig.)

  19. Image-based Proof of Work Algorithm for the Incentivization of Blockchain Archival of Interesting Images

    OpenAIRE

    Billings, Jake

    2017-01-01

    A new variation of blockchain proof of work algorithm is proposed to incentivize the timely execution of image processing algorithms. A sample image processing algorithm is proposed to determine interesting images using analysis of the entropy of pixel subsets within images. The efficacy of the image processing algorithm is examined using two small sets of training and test data. The interesting image algorithm is then integrated into a simplified blockchain mining proof of work algorithm bas...

  20. 16 multi-slice CT three-dimensional and multiplanar reconstruction for evaluation of pediatric congenital scoliosis

    International Nuclear Information System (INIS)

    Peng Yun; Zhang Ningning; Zhang Xuejun; Sun Guoqiang; Zeng Jinjin

    2006-01-01

    Objective: Our study is to use of 16 MSCT three-dimensional images and multiplanar reconstruction images in the preoperative investigation of patients with congenital scoliosis, to study its technical advantage and work out surgical plan. Methods: Twenty-seven pediatric patients with congenital scoliosis processing between April to October 2004 were reviewed, including 13 boys and 14 girls. X-ray plain film and sixteen multi-slice CT examination on curved/standard multiplanar reconstruction and three- dimensional computed tomographic imaging may offer, many potential advantages for defining congenital spine anomalies liable to cause progression of scoliosis, including visualization of the deformity in any plane, from any angle, with the overlying structures subtracted. Results: Ten patients had segmentation defects, 6 patients underwent formation defects, 11 patients had complex, unclassifiable anomalies. The patients of rib deformity were found in 15 patients, the most prominent part of the rib cage deformity was at the same level as the most rotated vertebra in 7 patients; 8 patients had vertebral anomalies accompanied with diastematomyelie, including 6 patients with uncompleted or completed bony spur. In 19 of 27 cases, the muhiplanar reconstruction and three-dimensional images allowed identification of unrecognized malformations and completely evaluated the degree of scoliosis, during conventional X-ray images and axial CT images, including volume 3D imaging evaluated approximately classification and modality of complex anomalies in 11 cases, which were unclassifiable malformation in 7 cases and unsegmented bar with contralateral hemivertebrae; 4 children had segmentation defects revealed unilateral unsegmented bar (3 cases) and bilateral block vertebra (1 case) in volume 3D reconstruction images; 2 children were found occultation hemivertebrae which were not been discovered during conventional X-ray images and axial CT images; and 2 children were revaluated

  1. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  2. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Schedel, H.; Stoeckle, U.; Wellmann, A.; Beier, J.; Wicht, L.; Hoffmann, R.; Felix, R.

    1996-01-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [de

  3. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  4. [Fetal neurosonography using 3-dimensional multiplanar sonography].

    Science.gov (United States)

    Chaoui, R; Heling, K S; Kainer, F; Karl, K

    2012-04-01

    This review focuses on the examination of the fetal brain, using three-dimensional (3D) ultrasound and the multiplanar rendering mode (MPR). The routine examination of the brain is achieved with axial planes but a dedicated fetal neurosonogram requires additional coronal and sagittal views, in order to provide a complete view of the different brain structures. Because these planes are difficult to obtain under many conditions, the present paper shows how 3D MPR allows one to obtain 1 or multiple reconstructed images from a digital volume. The display can be either as orthogonal planes, tomographic planes with parallel slices or as one single plane of the region of interest, which can be selected by the examiner. This approach allows easily the demonstration of the corpus callosum, the cerebellar vermis, the three-horn view, the foetal hippocampus and other regions. In addition, early neurosonography of the developing brain from the 7th week of pregnancy onwards can be achieved. © Georg Thieme Verlag KG Stuttgart · New York.

  5. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  6. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  7. Diagnosis of Peripheral Lung Lesions via Conventional Flexible Bronchoscopy with Multiplanar CT Planning

    Directory of Open Access Journals (Sweden)

    Marianne Anastasia De Roza

    2016-01-01

    Full Text Available Background. Conventional flexible bronchoscopy has limited sensitivity in the diagnosis of peripheral lung lesions and is dependent on lesion size. However, advancement of CT imaging offers multiplanar reconstruction facilitating enhanced preprocedure planning. This study aims to report efficacy and safety while considering the impact of patient selection and multiplanar CT planning. Method. Prospective case series of patients with peripheral lung lesions suspected of having lung cancer who underwent flexible bronchoscopy (forceps biopsy and lavage. Endobronchial lesions were excluded. Patients with negative results underwent CT-guided transthoracic needle aspiration, surgical biopsy, or clinical-radiological surveillance to establish the final diagnosis. Results. 226 patients were analysed. The diagnostic yield of bronchoscopy was 80.1% (181/226 with a sensitivity of 84.2% and specificity of 100%. In patients with a positive CT-Bronchus sign, the diagnostic yield was 82.4% compared to 72.8% with negative CT-Bronchus sign (p=0.116. Diagnostic yield was 84.9% in lesions > 20 mm and 63.0% in lesions ≤ 20 mm (p=0.001. Six (2.7% patients had transient hypoxia and 2 (0.9% had pneumothorax. There were no serious adverse events. Conclusion. Flexible bronchoscopy with appropriate patient selection and preprocedure planning is more efficacious in obtaining a diagnosis in peripheral lung lesions compared to historical data. This trial is registered with ClinicalTrials.gov Identifier: NCT01374542.

  8. Investigation of reconstruction conditions in sagittal-plane multiplanar reconstruction of the temporal bone

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Ichikawa, Ginichiro; Kobayashi, Kenichi; Ando, Ichiro

    2002-01-01

    In recent years, it has become possible to quickly obtain a large amount of 3D data with high continuity by helical CT scanning, in which the body is scanned continuously in a helical fashion. MPR (multiplanar reconstruction) can be performed using this data to generate images in arbitrary sectional planes, making it possible to obtain sagittal-plane images of the highest quality, which is useful for surgical planning. However, the procedures involved are rather complicated. Therefore, this study was conducted to investigate conditions for standardization of sagittal-plane MPR examinations performed using Xvigor CT scanners and Xtension. The results showed that a slice interval of 1 mm, no imaging filter, a zooming factor of 1.5, a window level of 350, and a window width of 3500 are the optimal imaging conditions. The stapes can be visualized in 70% of cases with sagittal-plane MPR based on axial images, and can be recognized at surgery in 75% or more of cases. Images of consistent quality can be obtained by standardizing the conditions for sagittal-plane MPR, which should prove advantageous in the clinical setting. (author)

  9. Can independent coronal multiplanar reformatted images obtained using state-of-the-art MDCT scanners be used for primary interpretation of MDCT of the abdomen and pelvis? A feasibility study

    International Nuclear Information System (INIS)

    Sebastian, Sunit; Kalra, Mannudeep K.; Mittal, Pardeep; Saini, Sanjay; Small, William C.

    2007-01-01

    Purpose: To evaluate if coronal reformatted images can be used for primary interpretation of MDCT of the abdomen and pelvis using 64-slice MDCT. Materials and methods: IRB approval was obtained. We reviewed MDCT studies of the abdomen and pelvis of 220 consecutive patients performed with 64 row MDCT with constant scanning parameters. Based on a 0.625 mm raw data set, transverse images were reconstructed at 5 mm and coronal images at 3 mm using standard reconstruction algorithms. Reader familiarity was achieved by simultaneous evaluation of transverse and coronal reformats in an initial group of 20 separate cases for findings in consensus. Two subsequent phases of image analysis were then performed in two groups of 100 patients each. In the first phase two radiologists evaluated the added utility of simultaneous review of MDCT of transverse and coronal reformatted images over transverse images alone in 100 consecutive patients referred for MDCT of the abdomen and pelvis. In the second phase, the same radiologists evaluated whether coronal multiplanar reformats could be used for primary interpretation of MDCT of the abdomen and pelvis in a separate but similar cohort of 100 consecutive abdominopelvic MDCT studies. The number of lesion(s), their location, size of smallest lesion, presence of artifacts and likely diagnosis were noted at each image interpretation. Image quality and confidence for interpretation was evaluated using five-point and three-point scale, respectively. The time required for primary interpretation of coronal reformats and transverse images were recorded. Statistical analysis was performed using Wilcoxon signed rank test. Results: Both readers detected additional findings (n = 37, 35), respectively, on simultaneous review of transverse and coronal reformats as compared with transverse images alone (p < 0.001). Excellent interobserver agreement was noted (r = 0.94-0.96). Both readers detected additional findings (n = 62, 53), respectively, on

  10. Development of a small prototype for a proof-of-concept of OpenPET imaging

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko; Inaniwa, Taku; Sato, Shinji; Nakajima, Yasunori; Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio

    2011-01-01

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with 11 C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with 18 F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  11. Development of a small prototype for a proof-of-concept of OpenPET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inaniwa, Taku; Sato, Shinji [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Nakajima, Yasunori [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio, E-mail: taiga@nirs.go.jp [Chiba University, 1-33 Yayoicho, Inage-ku, Chiba 263-8522 (Japan)

    2011-02-21

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with {sup 11}C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with {sup 18}F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  12. Tamper-proof secret image-sharing scheme for identifying cheated secret keys and shared images

    Science.gov (United States)

    Chen, Chien-Chang; Liu, Chong-An

    2013-01-01

    A (t,n) secret image-sharing scheme shares a secret image to n participants, and the t users recover the image. During the recovery procedure of a conventional secret image-sharing scheme, cheaters may use counterfeit secret keys or modified shared images to cheat other users' secret keys and shared images. A cheated secret key or shared image leads to an incorrect secret image. Unfortunately, the cheater cannot be identified. We present an exponent and modulus-based scheme to provide a tamper-proof secret image-sharing scheme for identifying cheaters on secret keys or shared images. The proposed scheme allows users to securely select their secret key. This assignment can be performed over networks. Modulus results of each shared image is calculated to recognize cheaters of a shared image. Experimental results indicate that the proposed scheme is excellent at identifying cheated secret keys and shared images.

  13. Three-dimensional short-range MR angiography and multiplanar reconstruction images in the evaluation of neurovascular compression in hemifacial spasm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Woo Suk; Kim, Eui Jong; Lee, Jae Gue; Rhee, Bong Arm [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1998-08-01

    To evaluate the diagnostic efficacy of three-dimensional(3D) short-range MR angiography(MRA) and multiplanar reconstruction(MPR) imaging in hemifacial spasm(HS). Materials and Methods : Two hundreds patients with HS were studied using a 1.5T MRI system with a 3D time-of-flight(TOF) MRA sequence. To reconstruct short-range MRA, 6-10 source images near the 7-8th cranial nerve complex were processed using a maximum-intensity projection technique. In addition, an MPR technique was used to investigate neurovascular compression. We observed the relationship between the root-exit zone(REZ) of the 7th cranial nerve and compressive vessel, and identified the compressive vessels on symptomatic sides. To investigate neurovascular contact, asymptomatic contralateral sides were also evaluated. Results : MRI showed that in 197 of 200 patients there was vascular compression or contact with the facial nerve REZ on symptomatic sides. One of the three remaining patients was suffering from acoustic neurinoma on the symptomatic side, while in two patients there were no definite abnormal findings.Compressive vessels were demonstrated in all 197 patients; 80 cases involved the anterior inferior cerebellar artery(AICA), 74 the posterior cerebellar artery(PICA), 13 the vertebral artery(VA), 16 the VA and AICA, eight the VA and PICA, and six the AICA and PICA. In all 197 patients, compressive vessels were reconstructed on one 3D short-range MRA image without discontinuation from vertebral or basilar arteries. 3D MPR studies provided additional information such as the direction of compression and course of the compressive vessel. In 31 patients there was neurovascular contact on the contralateral side at the 7-8th cranial nerve complex. Conclusion : Inpatients with HS, 3D short-range MRA and MPR images are excellent and very helpful for the investigation of neurovascular compression and the identification of compressive vessels.

  14. Three-dimensional short-range MR angiography and multiplanar reconstruction images in the evaluation of neurovascular compression in hemifacial spasm

    International Nuclear Information System (INIS)

    Choi, Woo Suk; Kim, Eui Jong; Lee, Jae Gue; Rhee, Bong Arm

    1998-01-01

    To evaluate the diagnostic efficacy of three-dimensional(3D) short-range MR angiography(MRA) and multiplanar reconstruction(MPR) imaging in hemifacial spasm(HS). Materials and Methods : Two hundreds patients with HS were studied using a 1.5T MRI system with a 3D time-of-flight(TOF) MRA sequence. To reconstruct short-range MRA, 6-10 source images near the 7-8th cranial nerve complex were processed using a maximum-intensity projection technique. In addition, an MPR technique was used to investigate neurovascular compression. We observed the relationship between the root-exit zone(REZ) of the 7th cranial nerve and compressive vessel, and identified the compressive vessels on symptomatic sides. To investigate neurovascular contact, asymptomatic contralateral sides were also evaluated. Results : MRI showed that in 197 of 200 patients there was vascular compression or contact with the facial nerve REZ on symptomatic sides. One of the three remaining patients was suffering from acoustic neurinoma on the symptomatic side, while in two patients there were no definite abnormal findings.Compressive vessels were demonstrated in all 197 patients; 80 cases involved the anterior inferior cerebellar artery(AICA), 74 the posterior cerebellar artery(PICA), 13 the vertebral artery(VA), 16 the VA and AICA, eight the VA and PICA, and six the AICA and PICA. In all 197 patients, compressive vessels were reconstructed on one 3D short-range MRA image without discontinuation from vertebral or basilar arteries. 3D MPR studies provided additional information such as the direction of compression and course of the compressive vessel. In 31 patients there was neurovascular contact on the contralateral side at the 7-8th cranial nerve complex. Conclusion : Inpatients with HS, 3D short-range MRA and MPR images are excellent and very helpful for the investigation of neurovascular compression and the identification of compressive vessels

  15. Frequency and types of fractures in maxillofacial traumas. Assessment using MDCT with multiplanar and 3D reconstructions

    International Nuclear Information System (INIS)

    Tomich, G.; Baigorria, P.; Orlando, N.; Mejico, M.; Costamagna, C.; Villavicencio, R.

    2011-01-01

    Introduction: Maxillofacial trauma (MFT) is a common reason for attendance at Emergency Departments. The complex anatomy of the facial bones requires multiplanar imaging techniques for a proper evaluation. Objectives. To describe frequency and types of fractures in a series of patients with MFT evaluated by multi-slice computed tomography (MDCT) with multiplanar and 3D reconstructions. Materials and Methods: Facial bone CTs ordered for MFT by the Emergency Department from June 2008 to December 2009 were retrospectively reviewed. The following data were obtained: age, gender, cause of trauma, presence and type of fractures. Patients were evaluated with an 8-channel MDCT. Multiplanar reconstructions were performed in all cases using high resolution bone window and soft tissue window, as well as 3D reconstructions. Results: One-hundred and thirty-seven CTs were performed for MFT: 78 (57%) showed 131 fractures. Of these 78 patients, 52 (66%) were males and 26 (34%) were females; mean age 33 years old (range: 14-90 yrs.). Causes: 58 % were injuries from traffic accidents; 24% were injuries from fights; 13% were sport injuries; and 7% were due to miscellaneous etiologies. Type and frequency of fractures: 18.3% were orbital floor fractures, 16% were maxillary sinus fractures, 15.3% were nasal fractures, 13% were jaw fractures, 9.2% were orbital fractures, and 12.3% were fractures of the zygomatic-malar complex; two cases of Le Fort II-III fractures were also observed. Conclusions: Fractures were more common in males, in the age range from 15 to 35 years old. Most fractures, and the most complex ones, were caused by traffic accidents. The most common fracture, either isolated or associated with other fractures, was the orbital floor fracture. (authors)

  16. Frecuencia y tipo de fracturas en traumatismos maxilofaciales: Evaluación con Tomografía Multislice con reconstrucciones multiplanares y tridimensionales Frequency and types of fractures in maxillofacial traumas: Assessment using MDCT with multiplanar and 3D reconstructions

    OpenAIRE

    Gabriela Tomich; Patricio Baigorria; Nicolás Orlando; Mariano Méjico; Cecilia Costamagna; Roberto Villavicencio

    2011-01-01

    Introducción. Los traumatismos maxilofaciales (TMF) representan un motivo de consulta común en los servicios de Urgencias. La compleja anatomía del macizo facial requiere de métodos de imágenes multiplanares para su correcta evaluación. Objetivos. Describir la frecuencia y tipos de fracturas en una serie de pacientes con TMF evaluados mediante tomografía computada multislice (TCMS) con reconstrucciones multiplanares y tridimensionales. Materiales y Métodos. Se revisaron en forma retrospectiva...

  17. The spectrum of benign esophageal lesions: imaging findings

    International Nuclear Information System (INIS)

    Jang, Kyung Mi; Lee, Kyung Soo; Lee, Soon Jin; Kim, Eun A; Kim, Tae Sung; Han, Dae Hee; Shim, Young Mog

    2002-01-01

    Benign esophageal lesions occur in various diseases. Barium studies are useful for the evaluation of mucosal surface lesions but provide little information about the extramucosal extent of disease. Computed tomography and magnetic resonance imaging, on the other hand, permit the assessment of wall thickness, mediastinal involvement, adjacent lymphadenopathy, and distant spread. In diseases such as fibrovascular polyps, duplication cysts, scleroderma, trauma, caustic esophagitis, hiatal hernia, esophageal diverticulum, achalasia, and paraesophageal varices, the findings of imaging studies are specific, obviating the need for further invasive diagnostic work-up. The advent of helical computed tomography and its volume data set allows the acquisition of multiplanar images, and magnetic resonance imaging is useful both for this and for tissue characterization. Thus, multiplanar cross-sectional imaging further extends the role of imaging modalities to the evaluation of benign esophageal lesions. Through an awareness of the multiplanar cross-sectional appearances of various benign esophageal lesions, the radiologist can play an important role in the detection, diagnosis, further diagnostic planning, and treatment of the diseases in which they occur

  18. The spectrum of benign esophageal lesions: imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Lee, Kyung Soo; Lee, Soon Jin; Kim, Eun A; Kim, Tae Sung; Han, Dae Hee; Shim, Young Mog [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2002-09-01

    Benign esophageal lesions occur in various diseases. Barium studies are useful for the evaluation of mucosal surface lesions but provide little information about the extramucosal extent of disease. Computed tomography and magnetic resonance imaging, on the other hand, permit the assessment of wall thickness, mediastinal involvement, adjacent lymphadenopathy, and distant spread. In diseases such as fibrovascular polyps, duplication cysts, scleroderma, trauma, caustic esophagitis, hiatal hernia, esophageal diverticulum, achalasia, and paraesophageal varices, the findings of imaging studies are specific, obviating the need for further invasive diagnostic work-up. The advent of helical computed tomography and its volume data set allows the acquisition of multiplanar images, and magnetic resonance imaging is useful both for this and for tissue characterization. Thus, multiplanar cross-sectional imaging further extends the role of imaging modalities to the evaluation of benign esophageal lesions. Through an awareness of the multiplanar cross-sectional appearances of various benign esophageal lesions, the radiologist can play an important role in the detection, diagnosis, further diagnostic planning, and treatment of the diseases in which they occur.

  19. Quantification of resolution in multiplanar reconstructions for digital breast tomosynthesis

    Science.gov (United States)

    Vent, Trevor L.; Acciavatti, Raymond J.; Kwon, Young Joon; Maidment, Andrew D. A.

    2016-03-01

    Multiplanar reconstruction (MPR) in digital breast tomosynthesis (DBT) allows tomographic images to be portrayed in various orientations. We have conducted research to determine the resolution of tomosynthesis MPR. We built a phantom that houses a star test pattern to measure resolution. This phantom provides three rotational degrees of freedom. The design consists of two hemispheres with longitudinal and latitudinal grooves that reference angular increments. When joined together, the hemispheres form a dome that sits inside a cylindrical encasement. The cylindrical encasement contains reference notches to match the longitudinal and latitudinal grooves that guide the phantom's rotations. With this design, any orientation of the star-pattern can be analyzed. Images of the star-pattern were acquired using a DBT mammography system at the Hospital of the University of Pennsylvania. Images taken were reconstructed and analyzed by two different methods. First, the maximum visible frequency (in line pairs per millimeter) of the star test pattern was measured. Then, the contrast was calculated at a fixed spatial frequency. These analyses confirm that resolution decreases with tilt relative to the breast support. They also confirm that resolution in tomosynthesis MPR is dependent on object orientation. Current results verify that the existence of super-resolution depends on the orientation of the frequency; the direction parallel to x-ray tube motion shows super-resolution. In conclusion, this study demonstrates that the direction of the spatial frequency relative to the motion of the x-ray tube is a determinant of resolution in MPR for DBT.

  20. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT

    International Nuclear Information System (INIS)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W.; Koester, M.

    1999-01-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [de

  1. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  2. Stork Color Proofing Technology

    Science.gov (United States)

    Ekman, C. Frederick

    1989-04-01

    For the past few years, Stork Colorproofing B.V. has been marketing an analog color proofing system in Europe based on electrophoto-graphic technology it pioneered for the purpose of high resolution, high fidelity color imaging in the field of the Graphic Arts. Based in part on this technology, it will make available on a commercial basis a digital color proofing system in 1989. Proofs from both machines will provide an exact reference for the user and will look, feel, and behave in a reproduction sense like the printed press sheet.

  3. Indications for direct multidirectional or multiplanar electronic reconstructions in CT-scanning of the head

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Veiga-Pires, J.A.; Gooskens, R.; Troost, J.

    1982-01-01

    The authors set out to indicate the optimal applications at minimum radiation penalty of both direct multidirectional and multiplanar electronic reconstruction modes in CT-scanning of the head by means of two illustrative case reports of midline congenital tumours. (orig.)

  4. Low-dose computed tomographic imaging in orbital trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, A.; Whitehouse, R.W. (Manchester Univ. (United Kingdom). Dept. of Diagnostic Radiology)

    1993-08-01

    The authors review findings in 75 computed tomographic (CT) examinations of 66 patients with orbital trauma who were imaged using a low-radiation-dose CT technique. Imaging was performed using a dynamic scan mode and exposure factors of 120 kVp and 80 mAs resulting in a skin dose of 11 mGy with an effective dose-equivalent of 0.22 mSv. Image quality was diagnostic in all cases and excellent in 73 examinations. Soft-tissue abnormalities within the orbit including muscle adhesions were well demonstrated both on primary axial and reconstructed multiplanar images. The benefits of multiplanar reconstructions are stressed and the contribution of soft-tissue injuries to symptomatic diplopia examined. (author).

  5. An evaluation of the regional cerebral blood flow (rCBF) measurement by xenon-enhanced dynamic CT with helical scanning technique and the functional imaging by multiplanar reconstruction (MPR). Fundamental study and clinical application

    International Nuclear Information System (INIS)

    Watanabe, Kenichi

    1997-01-01

    We evaluated the quantitative rCBF by xenon-enhanced dynamic CT with helical scanning technique on all brain regions, and also examined clinical usefulness of coronal and sagittal section images which are similar to SPECT images obtained by the functional multiplanar reconstitution (MPR) imaging of many successive flow maps. We used 14 clinical cases. The conventional xenon-enhanced CT was simple and ideal method to measure rCBF, however, it had disadvantages; it gives a few laminagraphical images or only the axial directional images, compared to SPECT or PET. There is a risk to overlook lesions out of the image or not to obtain the whole images of the lesion. Although the helical scanning technique has a methodological characteristics to use adjacent data for the image reconstitution, it is by no means inferior to the conventional method in the contrast resolution or the image resolution when the co-helical function and an appropriate reconstituted function were used. It has an advantage to scan all brain regions by only one cycle of scanning. Furthermore on making good use of the property that the helical scanning technique can give the successive data, we can observe rCBF by coronal and sagittal images when many flow maps were made up by reconstituted images of the narrow steps. This shows the clinical usefulness of this technique. One of the future problem to be solved is to decrease the exposure dose. (K.H.)

  6. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  7. Proof in Algebra: Reasoning beyond Examples

    Science.gov (United States)

    Otten, Samuel; Herbel-Eisenmann, Beth A.; Males, Lorraine M.

    2010-01-01

    The purpose of this article is to provide an image of what proof could look like in beginning algebra, a course that nearly every secondary school student encounters. The authors present an actual classroom vignette in which a rich opportunity for student reasoning arose. After analyzing the proof schemes at play, the authors provide a…

  8. Post-processing of digital images.

    Science.gov (United States)

    Perrone, Luca; Politi, Marco; Foschi, Raffaella; Masini, Valentina; Reale, Francesca; Costantini, Alessandro Maria; Marano, Pasquale

    2003-01-01

    Post-processing of bi- and three-dimensional images plays a major role for clinicians and surgeons in both diagnosis and therapy. The new spiral (single and multislice) CT and MRI machines have allowed better quality of images. With the associated development of hardware and software, post-processing has become indispensable in many radiologic applications in order to address precise clinical questions. In particular, in CT the acquisition technique is fundamental and should be targeted and optimized to obtain good image reconstruction. Multiplanar reconstructions ensure simple, immediate display of sections along different planes. Three-dimensional reconstructions include numerous procedures: multiplanar techniques as maximum intensity projections (MIP); surface rendering techniques as the Shaded Surface Display (SSD); volume techniques as the Volume Rendering Technique; techniques of virtual endoscopy. In surgery computer-aided techniques as the neuronavigator, which with information provided by neuroimaging helps the neurosurgeon in simulating and performing the operation, are extremely interesting.

  9. Multiplanar reconstruction computed tomography for diagnosis of scaphoid waist fracture union: a prospective cohort analysis of accuracy and precision

    Energy Technology Data Exchange (ETDEWEB)

    Hannemann, P.F.W.; Brouwers, L.; Gottgens, K.W.A.; Poeze, M.; Brink, P.R.G. [Maastricht University Medical Centre, Department of Surgery and Traumasurgery, PO Box 5800, Maastricht (Netherlands); Zee, D. van der; Stadler, A.; Weijers, R. [Maastricht University Medical Centre, Department of radiology, PO Box 5800, Maastricht (Netherlands)

    2013-10-15

    To examine reliability and validity concerning union of scaphoid fractures determined by multiplanar reconstruction computed tomography randomized at 6, 12, and 24 weeks after injury. We used Fleiss' kappa to measure the opinions of three observers reviewing 44 sets of computed tomographic scans of 44 conservatively treated scaphoid waist fractures. We calculated kappa for the extent of consolidation (0-24 %, 25-49 %, 50-74 %, or 75-100 %) on the transverse, sagittal and coronal views. We also calculated kappa for no union, partial union, and union, and grouped the results for 6, 12, and 24 weeks after injury. As the reference standard for union, CT scans were performed at a minimum of 6 months after injury to determine validity. Overall inter-observer agreement was found to be moderate ({kappa} = 0.576). No union ({kappa} = 0.791), partial union ({kappa} = 0.502), and union ({kappa} = 0.683) showed substantial, moderate, and substantial agreement, respectively. The average sensitivity of multiplanar reconstruction CT for diagnosing union of scaphoid waist fractures was 73 %. The average specificity was 80 %. Our results suggest that multiplanar reconstruction computed tomography is a reliable and accurate method for diagnosing union or nonunion of scaphoid fractures. However, inter-observer agreement was lower with respect to partial union. (orig.)

  10. Multiplanar reconstruction computed tomography for diagnosis of scaphoid waist fracture union: a prospective cohort analysis of accuracy and precision

    International Nuclear Information System (INIS)

    Hannemann, P.F.W.; Brouwers, L.; Gottgens, K.W.A.; Poeze, M.; Brink, P.R.G.; Zee, D. van der; Stadler, A.; Weijers, R.

    2013-01-01

    To examine reliability and validity concerning union of scaphoid fractures determined by multiplanar reconstruction computed tomography randomized at 6, 12, and 24 weeks after injury. We used Fleiss' kappa to measure the opinions of three observers reviewing 44 sets of computed tomographic scans of 44 conservatively treated scaphoid waist fractures. We calculated kappa for the extent of consolidation (0-24 %, 25-49 %, 50-74 %, or 75-100 %) on the transverse, sagittal and coronal views. We also calculated kappa for no union, partial union, and union, and grouped the results for 6, 12, and 24 weeks after injury. As the reference standard for union, CT scans were performed at a minimum of 6 months after injury to determine validity. Overall inter-observer agreement was found to be moderate (κ = 0.576). No union (κ = 0.791), partial union (κ = 0.502), and union (κ = 0.683) showed substantial, moderate, and substantial agreement, respectively. The average sensitivity of multiplanar reconstruction CT for diagnosing union of scaphoid waist fractures was 73 %. The average specificity was 80 %. Our results suggest that multiplanar reconstruction computed tomography is a reliable and accurate method for diagnosing union or nonunion of scaphoid fractures. However, inter-observer agreement was lower with respect to partial union. (orig.)

  11. Performing particle image velocimetry using artificial neural networks: a proof-of-concept

    Science.gov (United States)

    Rabault, Jean; Kolaas, Jostein; Jensen, Atle

    2017-12-01

    Traditional programs based on feature engineering are underperforming on a steadily increasing number of tasks compared with artificial neural networks (ANNs), in particular for image analysis. Image analysis is widely used in fluid mechanics when performing particle image velocimetry (PIV) and particle tracking velocimetry (PTV), and therefore it is natural to test the ability of ANNs to perform such tasks. We report for the first time the use of convolutional neural networks (CNNs) and fully connected neural networks (FCNNs) for performing end-to-end PIV. Realistic synthetic images are used for training the networks and several synthetic test cases are used to assess the quality of each network’s predictions and compare them with state-of-the-art PIV software. In addition, we present tests on real-world data that prove ANNs can be used not only with synthetic images but also with more noisy, imperfect images obtained in a real experimental setup. While the ANNs we present have slightly higher root mean square error than state-of-the-art cross-correlation methods, they perform better near edges and allow for higher spatial resolution than such methods. In addition, it is likely that one could with further work develop ANNs which perform better that the proof-of-concept we offer.

  12. Need for three-dimensional imaging in postsurgical ''falled back'' syndrome

    International Nuclear Information System (INIS)

    Zinreich, S.J.; Wang, H.; Long, D.M.; Quinn, C.M.; Rosenbaum, A.E.

    1987-01-01

    One hundred ten patients with persistent symptoms after low back surgery were examined with direct axial CT, 2D multiplanar, and 3D imaging. Sixty-three of these patients had lumbar spinal fusion. The 3D images were found to best display the integrity of fusion (assessed by continuity, pseudoarthrosis, incomplete fusion, transitional syndrome) in 44 of the 63 patients (65%). In 55 of the 110 patients lateral spinal stenosis was found; in 43% (24 of 55) this was uncovered on the 3D images. 3D also better showed the extent and type of surgery performed in 23% (26 of 110). Furthermore, 15 pars interarticularis, four facet fractures, and eight spinal malalignments were perceived only on 3D. 3D image afforded additional information over the direct axial and multiplanar reconstruction techniques in 63 of 110 patients

  13. MR imaging of articular cartilage : comparison of magnetization transfer contrast and fat-suppression in multiplanar and 3D gradient-echo, spin-echo, turbo spin-echo techniques

    International Nuclear Information System (INIS)

    Lee, Young Joon; Joo, Eun Young; Eun, Choong Ki

    1999-01-01

    The purpose of this study was to evaluate the effects of magnetization transfer contrast(MTC) and fat-suppression(FS) in variable spin-echo and gradient-echo sequences for articular cartilage imaging and to determine the optimal pulse sequences. Using variable 7-pulse sequences, the knees of 15 pigs were imaged Axial images were obtained using proton density and T2-weighted spin-echo (PDWSE and T2WSE), turbo spin-echo (TSE), multiplanar gradient-echo (MPGR), and 3D steady-state gradient-echo (3DGRE) sequences, and the same pulse sequences were then repeated using MTC. Also T1-weighted spin-echo(T1WSE) and 3D spoiled gradient-echo(3DSPGR) images of knees were also acquired, and the procedure was repeated using FS. For each knee, a total of 14 axial images were acquired, and using a 6-band scoring system, the visibility of and the visibilities of the the articular cartilage was analyzed. The visual effect of MTC and FS was scored using a 4-band scale. For each image, the signal intensities of articular cartilage, subchondral bone, muscles, and saline were measured, and signal-to-noise ratios(SNR) and contrast-to-noise ratios(CNR) were also calculated. Visibility of the cartilage was best when 3DSPGR and T1WSE sequences were used. MTC imaging increased the negative contrast between cartilage and saline, but FS imaging provided more positive contrast. CNR between cartilage and saline was highest when using TSE with FS(-351.1±15.3), though CNR between cartilage and bone then fell to -14.7±10.8. In MTC imaging using MPGR showed the greatest increase of negative contrast between cartilage and saline(CNR change=-74.7); the next highest was when 3DGRE was used(CNR change=-34.3). CNR between cartilage and bone was highest with MPGR(161.9±17.7), but with MTC, the greatest CNR decrease(-81.8) was observed. The greatest CNR increase between cartilage and bone was noted in T1WSE with FS. In all scans, FS provided a cartilage-only positive contrast image, though the absolute

  14. Adaptive tight frame based medical image reconstruction: a proof-of-concept study for computed tomography

    International Nuclear Information System (INIS)

    Zhou, Weifeng; Cai, Jian-Feng; Gao, Hao

    2013-01-01

    A popular approach for medical image reconstruction has been through the sparsity regularization, assuming the targeted image can be well approximated by sparse coefficients under some properly designed system. The wavelet tight frame is such a widely used system due to its capability for sparsely approximating piecewise-smooth functions, such as medical images. However, using a fixed system may not always be optimal for reconstructing a variety of diversified images. Recently, the method based on the adaptive over-complete dictionary that is specific to structures of the targeted images has demonstrated its superiority for image processing. This work is to develop the adaptive wavelet tight frame method image reconstruction. The proposed scheme first constructs the adaptive wavelet tight frame that is task specific, and then reconstructs the image of interest by solving an l 1 -regularized minimization problem using the constructed adaptive tight frame system. The proof-of-concept study is performed for computed tomography (CT), and the simulation results suggest that the adaptive tight frame method improves the reconstructed CT image quality from the traditional tight frame method. (paper)

  15. CT Imaging of facial trauma. The role of different types of reconstruction. Part II - soft tissues

    International Nuclear Information System (INIS)

    Myga-Porosilo, J.; Sraga, W.; Borowiak, H.; Jackowska, Z.; Kluczewska, E.; Skrzelewski, S.

    2011-01-01

    Background: Injury to facial soft tissues as a complication of skeleton fractures is an important problem among patients with facial trauma. The aim of this work was to assess the value of multiplanar and three-dimensional (3D) reconstruction computed tomography (CT) images obtained by using multi-detector row technology in spiral data acquisition in patients with facial injuries of soft tissue. Material/Methods: Sixty-seven patients diagnosed with injury to the facial skeleton underwent a CT scan with the use of GE Hispeed Qx/i scanner. For each patient: a two-dimensional (2D) multiplanar reconstruction (MPR), maximum intensity projection (MIP), and 3D volume rendering (VR) were conducted. Post-injury lesions of soft tissues were assessed. During the assessment of the post-injury lesions of soft tissues, the following features were evaluated: Extra ocular muscle and fat tissue herniation through fractures in the medial and inferior orbital walls. Fluid in the sinuses and in the nasal cavity. Subcutaneous tissue emphysema. Results: For subcutaneous emphysema and sinus fluid imaging, both the axial and the 2D image reconstruction proved comparably effective. However, 2D reconstructions were superior to transverse plane images with regard to herniations into fractures of the inferior orbital wall. 3D reconstruction has no importance in diagnosing soft tissue injuries. Conclusions: Multiplanar CT reconstructions increase the effectiveness of imaging of orbital tissue herniations, especially in case of fractures in the inferior orbital wall. In suspected soft tissue herniations, as well as prior to surgical treatment, spiral CT with 2D multiplanar reconstructions should be the method of choice. (authors)

  16. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    International Nuclear Information System (INIS)

    Dugas, Alexandre; Therasse, Éric; Kauffmann, Claude; Tang, An; Elkouri, Stephane; Nozza, Anna; Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles

    2012-01-01

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001–0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662–0.780) and single-plane MPR images (0.772–0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  17. Philosophy of mathematics an introduction to a world of proofs and pictures

    CERN Document Server

    Brown, James Robert

    1999-01-01

    This text discusses the great philosophers and the importance of mathematics to their thought. It includes topics such as: the mathematical image; platonism; picture-proofs; applied mathematics; Hilbert and Godel; knots and nations; definitions; picture-proofs and Wittgenstein; and computation, proof and conjecture.

  18. Interpretation of Radiological Images: Towards a Framework of Knowledge and Skills

    Science.gov (United States)

    van der Gijp, A.; van der Schaaf, M. F.; van der Schaaf, I. C.; Huige, J. C. B. M.; Ravesloot, C. J.; van Schaik, J. P. J.; ten Cate, Th. J.

    2014-01-01

    The knowledge and skills that are required for radiological image interpretation are not well documented, even though medical imaging is gaining importance. This study aims to develop a comprehensive framework of knowledge and skills, required for two-dimensional and multiplanar image interpretation in radiology. A mixed-method study approach was…

  19. The diagnostic value of multiplanar reconstruction on MDCT colonography for the preoperative staging of colorectal cancer

    International Nuclear Information System (INIS)

    Jin, Kwang Nam; Kim, Se Hyung; Lee, Jae Young; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn; Shin, Kyung-Sook

    2006-01-01

    The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists' performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both A Z (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P 0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641-0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone. (orig.)

  20. Diagnostic value of multiplanar reconstruction in CT recognition of lumbar spinal disorders

    International Nuclear Information System (INIS)

    Im, S. K.; Choi, J. H.; Kim, C. H.; Sohn, M. H.; Lim, K. Y.; Choi, K. C.

    1984-01-01

    The computer tomography is useful in evaluation of bony structures and adjacent soft tissues of the lumbar spine. Recently, the multiplanar reconstruction of lumbar spine of CT of significant value for the anatomical localization and for the myelographic and surgical correlation. We observed 177 cases of lumbar spine CT, who complains of spinal symptom, during the period from Dec. 1982 to Aug. 1984. The results were as follows: 1. The sex distribution of cases were 113 males and 44 females. The CT diagnosis showed 152 cases of herniated lumbar disc, 15 cases of degenerative disease, 5 cases of spine tbc., 3 cases of spine trauma and 2 cases of meningocele. 2. CT findings of herniated disc were as follows: focal protrusion of posterior disc margin and obliteration of anterior epidural fat in all cases, indentation on dural sac in 92 cases (60.5%) soft tissue mass in epidural fat in 85 cases (55.9%), compression or displacement of nerve root sheath in 22 cases(14.4%). 3. Sites of herniated lumbar disc were at L4-L5 level in 100 cases(59.1%) and at L5-S1 level in 65 cases (38.4%). Location of it were central type in 70 cases(41.1%), left-central type in 46 cases (27.2%), right-central type in 44 cases(26.0%) and lateral type in 9 cases (5.1%). 4. The sagittal reconstruction images were helpful in evaluating neural foramina, size of disc bluge into spinal canal, especially at L5-S1, and patients with spondylolisthesis. The coronal reconstruction images were the least informative, although they contributed to the evaluation of lumbar nerve roots of course, the axial CT scans were the most sensitive and specific.

  1. MR imaging of invasive carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Lien, H.H.

    1999-01-01

    MR imaging is noninvasive and provides direct multiplanar images with good contrast between different soft tissues. It has a potential in distinguishing normal from abnormal tissue and is a valuable technique in examination of the female pelvis. This report reviews the present role of MR imaging in the initial work-up of patients with carcinoma of the uterine cervix. (orig./AJ)

  2. Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y.R. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of); The Catholic University of Korea, Department of Radiology, Incheon St. Mary' s Hospital, College of Medicine, Bupyeong 6-dong, Bupyeong-gu, Incheon (Korea, Republic of); Rha, S.E.; Choi, B.G.; Oh, S.N.; Park, M.Y.; Byun, J.Y. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of)

    2013-04-15

    To compare three-dimensional (3D) T2-weighted turbo spin-echo (TSE) with multiplanar two-dimensional (2D) T2-weighted TSE for the evaluation of invasive cervical carcinoma. Seventy-five patients with cervical carcinoma underwent MRI of the pelvis at 3.0 T, using both 5-mm-thick multiplanar 2D (total acquisition time = 12 min 25 s) and 1-mm-thick coronal 3D T2-weighted TSE sequences (7 min 20 s). Quantitative analysis of signal-to-noise ratio (SNR) and qualitative analysis of image quality were performed. Local-regional staging was performed in 45 patients who underwent radical hysterectomy. The estimated SNR of cervical carcinoma and the relative tumour contrast were significantly higher on 3D imaging (P < 0.0001). Tumour conspicuity was better with the 3D sequence, but the sharpness of tumour margin was better with the 2D sequence. No significant difference in overall image quality was noted between the two sequences (P = 0.38). There were no significant differences in terms of the diagnostic accuracy, sensitivity, and specificity of parametrial invasion, vaginal invasion, and lymph node metastases. Multiplanar reconstruction 3D T2-weighted imaging is largely equivalent to 2D T2-weighted imaging for overall image quality and staging accuracy of cervical carcinoma with a shorter MR data acquisition, but has limitations with regard to the sharpness of the tumour margin. circle 3D T2-weighted MR sequence is equivalent to 2D for cervical carcinoma staging. (orig.)

  3. Imaging of spine injuries

    International Nuclear Information System (INIS)

    Lomoschitz, F. . e-mai: friedrich.lomoschitz@univie.ac.at

    2001-01-01

    Spinal trauma requires a prompt and detailed diagnosis for estimating the prognosis and installing proper therapy. Conventional radiograms are the first imaging modality in most cases. In the cervical and the lumbar spine, a CT has to be performed in patients with polytrauma and a higher risk of complications or with signs of instability. Especially for imaging the cervicocranium, multiplanar reformations in sagittal and coronal planes are necessary. For fractures of the thoracic spine, MR imaging is superior to CT because of the better detection of associated neurologic complications. (author)

  4. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  5. CT Imaging of facial trauma. Role of different types of reconstruction. Part I - bones

    International Nuclear Information System (INIS)

    Myga-Porosilo, J.; Sraga, W.; Borowiak, H.; Jackowska, Z.; Kluczewska, E.; Skrzelewski, S.

    2011-01-01

    Background: Injury to the facial skeleton and the adjoining soft tissues is a frequently occurring condition. The main aim of this work was to assess the value of multiplanar and three-dimensional (3D) reconstruction computed tomography (CT) images obtained by using multi-detector row technology in spiral data acquisition in patients with facial skeleton injury. The authors attempted to answer the following questions: Are there particular mechanisms and types of injuries or locations of fractures which can be diagnosed significantly more effectively by conducting additional multiplanar image reconstructions? Do 3D image reconstructions contribute to the diagnostic process, to what extent? Compared to other imaging techniques, is the spiral CT data acquisition a more convenient for the patient and a faster investigation method of diagnosing post-injury lesions involving the facial skeleton? Material/Methods: Sixty-seven patients diagnosed with injury to the facial skeleton were referred for emergent CT scanning. Each patient underwent a CT scan with the use of a GE HiSpeed Qx/i scanner. The scans were conducted with the use of spiral data acquisition technique in the transverse plane. The following secondary image reconstructions were conducted for each patient: a two dimensional (2D) multiplanar reconstruction (MPR), maximum intensity projection (MIP), and 3D volume rendering (VR). Post-injury lesions of the facial skeleton were assessed and the presence of any loose displaced bone fragments was taken into consideration. Results: As far as fracture imaging is concerned, the 2D image reconstruction and volume rendering proved to be the most effective in the majority of locations. 3D image reconstructions proved the most sensitive in most cases of loose displaced bone fragments, except for fine structures such as the ethmoid bone and the inferior orbital wall. Conclusions: 1. Multiplanar computer reconstructions increase the effectiveness of visualisation of

  6. Combinatorial Proofs and Algebraic Proofs

    Indian Academy of Sciences (India)

    Permanent link: https://www.ias.ac.in/article/fulltext/reso/018/07/0630-0645. Keywords. Combinatorial proof; algebraic proof; binomial identity; recurrence relation; composition; Fibonacci number; Fibonacci identity; Pascal triangle. Author Affiliations. Shailesh A Shirali1. Sahyadri School Tiwai Hill, Rajgurunagar Pune 410 ...

  7. Understanding mathematical proof

    CERN Document Server

    Taylor, John

    2014-01-01

    Introduction The need for proof The language of mathematics Reasoning Deductive reasoning and truth Example proofs Logic and ReasoningIntroduction Propositions, connectives, and truth tables Logical equivalence and logical implication Predicates and quantification Logical reasoning Sets and Functions Introduction Sets and membership Operations on setsThe Cartesian product Functions and composite functions Properties of functions The Structure of Mathematical ProofsIntroduction Some proofs dissected An informal framework for proofs Direct proof A more formal framework Finding Proofs Direct proo

  8. Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Yamagata, Hitoshi; Nogami, Munenobu; Kono, Atsushi; Sugimura, Kazuro

    2012-01-01

    Purpose: To evaluate potential benefits of using multiplanar reconstruction (MPR) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (MDCT). Materials and methods: MDCT datasets of 60 patients with suspected lung nodules were retrospectively collected. Using “second-read” CAD, two radiologists (Readers 1 and 2) independently interpreted these datasets for the detection of non-calcified nodules (≥4 mm) with concomitant confidence rating. They did this task twice, first without MPR (using only axial images), and then 4 weeks later with MPR (using also coronal and sagittal MPR images), where the total reading time per dataset, including the time taken to assess the detection results of CAD software (CAD assessment time), was recorded. The total reading time and CAD assessment time without MPR and those with MPR were statistically compared for each reader. The radiologists’ performance for detecting nodules without MPR and the performance with MPR were compared using jackknife free-response receiver operating characteristic (JAFROC) analysis. Results: Compared to the CAD assessment time without MPR (mean, 69 s and 57 s for Readers 1 and 2), the CAD assessment time with MPR (mean, 46 s and 45 s for Readers 1 and 2) was significantly reduced (P < 0.001). For Reader 1, the total reading time was also significantly shorter in the case with MPR. There was no significant difference between the detection performances without MPR and with MPR. Conclusion: The use of MPR has the potential to improve the workflow in CAD of lung nodules on MDCT.

  9. - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    International Nuclear Information System (INIS)

    Behnes, Michael; Akin, Ibrahim; Sartorius, Benjamin; Fastner, Christian; El-Battrawy, Ibrahim; Borggrefe, Martin; Haubenreisser, Holger; Meyer, Mathias; Schoenberg, Stefan O.; Henzler, Thomas

    2016-01-01

    A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. cCTA datasets were acquired on a 3 rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users

  10. Multiplanar transesophageal echocardiography for the evaluation and percutaneous management of ostium secundum atrial septal defects in the adult.

    Science.gov (United States)

    Sobrino, Ayax; Basmadjian, Arsène J; Ducharme, Anique; Ibrahim, Reda; Mercier, Lise-Andrée; Pelletier, Guy B; Marcotte, François; Garceau, Patrick; Burelle, Denis; O'Meara, Eileen; Dore, Annie

    2012-01-01

    The purpose of this paper is to review the usefulness of multiplanar transesophageal echocardiography before, during and after percutaneous transcatheter closure of secundum atrial septal defects. Transesophageal echocardiography imaging techniques,including their role in patient selection, procedural guidance and immediate assessment of technical success and complications are described and discussed in this review. Percutaneous transcatheter closure is indicated for ostium secundum atrial septal defects of less than 40 mm in maximal diameter. The defect must have a favorable anatomy, with adequate rims of at least 5 mm to anchor the prosthesis. Transesophageal echocardiography plays a critical role before the procedure in identifying potential candidates for percutaneous closure and to exclude those with unfavorable anatomy or associated lesions, which could not be addressed percutaneously. Transesophageal echocardiography is also important during the procedure to guide the deployment of the device. After device deployment, the echocardiographer must assess the device (integrity, position and stability), residual shunt, atrio-ventricular valve regurgitation, obstruction to systemic or venous return and pericardial effusion, in order to determine procedural success and diagnose immediate complications.

  11. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): Assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images

    International Nuclear Information System (INIS)

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-01-01

    Objective: The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Materials and methods: Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. Results: MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4 ± 1.1 mm, which was statistically smaller than that of 13 control patients, 6.0 ± 1.5 mm (P < 0.05, Wilcoxon rank sum tests). Conclusion: Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality.

  12. Student Teachers’ Proof Schemes on Proof Tasks Involving Inequality: Deductive or Inductive?

    Science.gov (United States)

    Rosyidi, A. H.; Kohar, A. W.

    2018-01-01

    Exploring student teachers’ proof ability is crucial as it is important for improving the quality of their learning process and help their future students learn how to construct a proof. Hence, this study aims at exploring at the proof schemes of student teachers in the beginning of their studies. Data were collected from 130 proofs resulted by 65 Indonesian student teachers on two proof tasks involving algebraic inequality. To analyse, the proofs were classified into the refined proof schemes level proposed by Lee (2016) ranging from inductive, which only provides irrelevant inferences, to deductive proofs, which consider addressing formal representation. Findings present several examples of each of Lee’s level on the student teachers’ proofs spanning from irrelevant inferences, novice use of examples or logical reasoning, strategic use examples for reasoning, deductive inferences with major and minor logical coherence, and deductive proof with informal and formal representation. Besides, it was also found that more than half of the students’ proofs coded as inductive schemes, which does not meet the requirement for doing the proof for the proof tasks examined in this study. This study suggests teacher educators in teacher colleges to reform the curriculum regarding proof learning which can accommodate the improvement of student teachers’ proving ability from inductive to deductive proof as well from informal to formal proof.

  13. Writing proofs in analysis

    CERN Document Server

    Kane, Jonathan M

    2016-01-01

    This is a textbook on proof writing in the area of analysis, balancing a survey of the core concepts of mathematical proof with a tight, rigorous examination of the specific tools needed for an understanding of analysis. Instead of the standard "transition" approach to teaching proofs, wherein students are taught fundamentals of logic, given some common proof strategies such as mathematical induction, and presented with a series of well-written proofs to mimic, this textbook teaches what a student needs to be thinking about when trying to construct a proof. Covering the fundamentals of analysis sufficient for a typical beginning Real Analysis course, it never loses sight of the fact that its primary focus is about proof writing skills. This book aims to give the student precise training in the writing of proofs by explaining exactly what elements make up a correct proof, how one goes about constructing an acceptable proof, and, by learning to recognize a correct proof, how to avoid writing incorrect proofs. T...

  14. Imaging in epilepsy

    International Nuclear Information System (INIS)

    Gupta, Arun Kumar; Sharma, Raju; Sarma, Dipanka

    2000-01-01

    Epilepsy is a common problem in the paediatric age group. Imaging plays a vital role in identifying the seizure focus. Cross-sectional imaging modalities like CT and MRI have had a major impact on the management of seizure disorders. MRI, because of its high contrast resolution and multiplanar capability is the ideal imaging modality but its use is restricted due to high cost. Computed tomography is cheaper and is the first, and often, the only modality used, especially in the under privileged areas of the world. In the tropical countries inflammatory granuloma are a common cause of epilepsy and CT is adequate to detect these lesions. Other causes include congenital abnormalities, neoplastic and vascular causes. (author)

  15. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu [Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California 95817 (United States); Kent, Michael S.; Wisner, Erik R. [Department of Surgical and Radiological Sciences, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Johnson, Lynelle R.; Stern, Joshua A. [Department of Medicine and Epidemiology, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Qi, Lihong [Department of Public Health Sciences, University of California Davis, Davis, California 95616 (United States); Fujita, Yukio [Department of Radiation Oncology, Tokai University, Isehara, Kanagawa 259-1193 (Japan); Boone, John M. [Department of Radiology, University of California Davis School of Medicine, Sacramento, California 95817 (United States)

    2016-07-15

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  16. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model.

    Science.gov (United States)

    Yamamoto, Tokihiro; Kent, Michael S; Wisner, Erik R; Johnson, Lynelle R; Stern, Joshua A; Qi, Lihong; Fujita, Yukio; Boone, John M

    2016-07-01

    Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. The mean TRE

  17. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    International Nuclear Information System (INIS)

    Yamamoto, Tokihiro; Kent, Michael S.; Wisner, Erik R.; Johnson, Lynelle R.; Stern, Joshua A.; Qi, Lihong; Fujita, Yukio; Boone, John M.

    2016-01-01

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  18. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T; Boone, J [University of California Davis School of Medicine, Sacramento, CA (United States); Kent, M; Wisner, E [University of California Davis School of Veterinary Medicine, Davis, CA (United States); Fujita, Y [Tokai University, Isehara (Japan)

    2015-06-15

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R{sup 2}=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  19. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    International Nuclear Information System (INIS)

    Yamamoto, T; Boone, J; Kent, M; Wisner, E; Fujita, Y

    2015-01-01

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R"2=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  20. PROOF on Demand

    International Nuclear Information System (INIS)

    Malzacher, Peter; Manafov, Anar

    2010-01-01

    PROOF on Demand (PoD) is a set of utilities, which allows starting a PROOF cluster at user request, on any resource management system. It provides a plug-in based system, which allows to use different job submission frontends, such as LSF or gLite WMS. Main components of PoD are the PROOFAgent and the PAConsole. PROOFAgent provides the communication layer between the PROOF master on the local machine and the PROOF workers on the remote resources, possibly behind a firewall. PAConsole provides a user-friendly GUI, which is used to setup, manage, and shutdown the dynamic PROOF cluster. Installation is simple and doesn't require administrator privileges, and all the processes run in user space. PoD gives users, who don't have a centrally-administrated static PROOF cluster at their institute, the possibility to enjoy the full power of interactive analysis with PROOF.

  1. Proof in geometry with "mistakes in geometric proofs"

    CERN Document Server

    Fetisov, A I

    2006-01-01

    This single-volume compilation of 2 books explores the construction of geometric proofs. It offers useful criteria for determining correctness and presents examples of faulty proofs that illustrate common errors. 1963 editions.

  2. The Development of LED-Based Dental Light Using a Multiplanar Reflector Design

    Directory of Open Access Journals (Sweden)

    Chi-Chang Hsieh

    2014-01-01

    Full Text Available A multiplanar reflector was designed to enhance the application efficiency of light-emitting diode (LED light sources that can be employed as LED-based dental lights. This study used a high-power LED developed by Nichia, that is, a single LED capable of providing a total luminous flux of 120 lm, as the primarily light source to design and develop an LED-based dental light. This LED complies with the international standards and regulations stipulated in ISO 9680:2007. The light spots produced by the prototype were rectangular, with a length of 200 mm and a width of 100 mm. These light spots achieved maximum illumination of 12,000 lux. The use of LEDs can reduce energy consumption from 50 W to 3 W, providing an energy saving of more than 90%.

  3. Four-channel multidetector-row computed tomography in the evaluation of facial fractures - optimized parameters for acquisition and multiplanar reformation

    International Nuclear Information System (INIS)

    Omid, P. M.

    2002-08-01

    The first part of this thesis is designed to give the reader a comprehensive survey on the complex basic principles of computed tomography (CT), from the early beginning to the recent development of multidetector-row CT (MD-CT). Attention is focused on imaging of trauma in general and on imaging of facial fractures in particular. The second part of this thesis describes a clinical study performed to optimize acquisition protocols and multiplanar reformation (MPR) algorithms for the evaluation of facial fractures using MD-CT, which has not been yet described in literature. For this study, a cadaver head with artificial blunt facial trauma was examined using a 4-channel MD-CT scanner. The influence of acquisition parameters (collimation: 2x0.5 mm/4x1 mm/4x2.5 mm; tube current: 120 mAs/90 mAs/60 mAs), image reconstruction algorithms (standard vs. ultra-high resolution (UHR) modes; reconstructed slice thicknesses: 0.5 mm/1 mm/3 mm; increment: 0.3 mm/0.6 mm/1.5 mm), and reformation algorithms (slice thicknesses: 0.5 mm/1 mm/3 mm; overlap: 0.5 mm/1 mm/3 mm) on detectability of facial fractures in MPRs with MD-CT was analyzed. Effects of algorithms and parameters on image noise, artifacts and delineation of soft tissues were evaluated. The results of this study reliably demonstrate that fracture detection was significantly higher with thin MPRs (0.5/0.5 mm, 1/0.5 mm, 1/1 mm) (p = 0 .014) acquired with 2x0.5 mm collimation (p = 0 .046), in UHR mode (p .0005) with 120 mAs (p = 0 .025). Inter-observer variability showed very good agreement (κ > = 0 .942). Non-UHR mode, lower mAs and thick MPRs (3/0.5 mm, 3/1 mm, 3/0.5 mm) showed significantly decreased detectability. (author)

  4. Proofs without Words: A Visual Application of Reasoning and Proof

    Science.gov (United States)

    Bell, Carol J.

    2011-01-01

    Reasoning and Proof is one of the Process Standards set forth in National Council of Teachers of Mathematics' (NCTM) "Principles and Standards for School Mathematics." Thus, it is important to give students opportunities to build their reasoning skills and aid their understanding of the proof process. Teaching students how to do proofs is a…

  5. Three dimensional digital rotational imaging in the evaluation of the fractures

    International Nuclear Information System (INIS)

    Chong, Se Min; Lee, Min Hee; Kwag, Hyon Joo; Lee, Young Rae; Kook, Shin Ho; Park, Hae Won; Moon, Woo Jin; Kim, Seung Kwon; Chung, Eun Chul

    2003-01-01

    To evaluate the usefulness and the application of three dimensional digital rotational imaging (3D DRI) by the evaluation of fractures. Sixteen patients with clinically diagnosed or suspicious fracture were involved in this study. The lesion or suspicious sites of all 16 cases were spines (n=7), pelvis (n=3) and so on (n=6; knee elbow, ankle, wrist and foot). In all cases, conventional radiography, multiplanar 2D (slice thickness/pitch=3 or 5 mm/1:1)and volume rendering 3D reconstructed single detector helical CT (HiSpeed Advantage, GE Medical Systems, Milwaukee, WIS) scans and 3D DRI (Integris V-5000, Philips Medical Systems, The Netherlands) with multiplanar intersection and gray scaling as postprocessing technique were performed. 3D DRI was evaluated and compared with conventional radiography, multiplanar 2D CT and volume rendering 3D CT. 3D DRI provided more detail and additional information in 14 cases (88%), comparing with 2D and 3D CT scans. Two fractures were revealed only on 3D DRI other than conventional radiography and CT scans and one case was revealed on 2D CT and 3D DRI. In all cases, we could acquired more detail and additional information from 3D DRI than from 3D CT in the acquisition of 3D imaging. 3D DRI didn't change the classification of fracture in 12 of 13 cases (92%), which revealed the fracture on the conventional radiography or CT. 3D DRI can diagnose and evaluate the fracture rapidly and easily with anatomical and spatial resolution by acquisition of 3D imaging with postprocessing using DRI

  6. Three dimensional digital rotational imaging in the evaluation of the fractures

    Energy Technology Data Exchange (ETDEWEB)

    Chong, Se Min; Lee, Min Hee; Kwag, Hyon Joo; Lee, Young Rae; Kook, Shin Ho; Park, Hae Won; Moon, Woo Jin; Kim, Seung Kwon; Chung, Eun Chul [School of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)

    2003-10-01

    To evaluate the usefulness and the application of three dimensional digital rotational imaging (3D DRI) by the evaluation of fractures. Sixteen patients with clinically diagnosed or suspicious fracture were involved in this study. The lesion or suspicious sites of all 16 cases were spines (n=7), pelvis (n=3) and so on (n=6; knee elbow, ankle, wrist and foot). In all cases, conventional radiography, multiplanar 2D (slice thickness/pitch=3 or 5 mm/1:1)and volume rendering 3D reconstructed single detector helical CT (HiSpeed Advantage, GE Medical Systems, Milwaukee, WIS) scans and 3D DRI (Integris V-5000, Philips Medical Systems, The Netherlands) with multiplanar intersection and gray scaling as postprocessing technique were performed. 3D DRI was evaluated and compared with conventional radiography, multiplanar 2D CT and volume rendering 3D CT. 3D DRI provided more detail and additional information in 14 cases (88%), comparing with 2D and 3D CT scans. Two fractures were revealed only on 3D DRI other than conventional radiography and CT scans and one case was revealed on 2D CT and 3D DRI. In all cases, we could acquired more detail and additional information from 3D DRI than from 3D CT in the acquisition of 3D imaging. 3D DRI didn't change the classification of fracture in 12 of 13 cases (92%), which revealed the fracture on the conventional radiography or CT. 3D DRI can diagnose and evaluate the fracture rapidly and easily with anatomical and spatial resolution by acquisition of 3D imaging with postprocessing using DRI.

  7. Imaging of the vagina and vulva

    International Nuclear Information System (INIS)

    Souza, Luis Ronan Marquez Ferreira de; Szejnfeld, Jacob; Signorini Filho, Roney Cesar; Marques, Renato Moretti; Nicolau, Sergio Mancini; Goldman, Suzan Menasce

    2006-01-01

    In gynecological daily practices, the vulva and vagina are examined during physical examination, however there are situations where this is not possible or it is needed to determine the extension of an injury through imaging methods. The magnetic resonance imaging is an excellent cross-sectional modality for evaluation the alterations of vulva and vagina due its multiplanar evaluation and high tecidual contrast. Other cross-sectional modalities are ultrasound and enhanced computed tomography. This paper intends to give an overview of vaginal and vulvar pathology that can be identified by the radiologist. (author)

  8. Measurements of angles of the normal auditory ossicles relative to the reference plane and image reconstruction technique for obtaining optimal sections of the ossicles in high-resolution multiplanar reconstruction using a multislice CT scanner

    International Nuclear Information System (INIS)

    Fujii, Naoko; Katada, Kazuhiro; Yoshioka, Satoshi; Takeuchi, Kenji; Takasu, Akihiko; Naito, Kensei

    2005-01-01

    Using high-resolution isotropic volume data obtained by 0.5 mm, 4-row multislice CT, cross-sectional observation of the auditory ossicles is possible from any desired direction without difficulty in high-resolution multiplanar reconstruction (HR-MPR) images, also distortion-free three-dimensional images of the ossicles are generated in three-dimensional CT (3D-CT) images. We measured angles of fifty normal ossicles relative to the reference plane, which has been defined as a plane through the bilateral infraorbital margins to the middle portion of the external auditory canal. Based on the results of angle measurement, four optimal sections of the ossicles for efficient viewing to the ossicular chain were identified. To understand the position of the angle measurement and the four sections, the ossicles and the reference plane were reconstructed in the 3D-CT images. As the result of observation of the ossicles and the reference plane, the malleus was parallel to the incudal long process and perpendicular to the reference plane. As the results of angle measurement, the mean angle of the tympanic portion of the facial nerve relative to the reference plane in the sagittal plane was found to be 17 deg, and the mean angle of the stapedial crura relative to the reference plane in the sagittal plane was found to be 6 deg. The mean angle of the stapes relative to the reference plane in the coronal plane was 44 deg, and the mean angle of the incudal long process relative to the stapes in the coronal plane was 89 deg. In 80% of ears, the stapes extended straight from the incudal long process. Image reconstruction technique for viewing four sections of the ossicles was investigated. Firstly, the image of the malleal head and the incudal short process was identified in the axial plane. Secondly, an image of the malleus along the malleal manubrium was reconstructed in the coronal plane. Thirdly, the image of the incudal long process was seen immediately behind the malletis image

  9. MR imaging in female pelvic organs prolapse

    International Nuclear Information System (INIS)

    Capiel, Carlos A. h; Bouzas, Carlos A.

    2003-01-01

    Pelvic floor weakness and consequent organ prolapse may result in a variety of symptoms, including pain, urinary or fecal incontinence and constipation. Diagnosis is made primary on the basis of findings at physical pelvic examination. Imaging is useful in patients in whom findings at physical examination are equivocal. Different imaging techniques (fluoroscopy, ultrasonography), can be useful in evaluating pelvic organs prolapse. MR imaging is a new noninvasive technique that provides a multiplanar global evaluation of the pelvic contents and demonstrates pelvic organs prolapse. Reference points are the pubococcygeal line and puborectalis muscle sling. This pictorial assay illustrates different grades of cystourethrocele, recto-sigmoidocele and hysteroptosis (uterine prolapse) on MR imaging. (author)

  10. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  11. Sports-related muscle injuries of the lower extremity: MR imaging appearances

    International Nuclear Information System (INIS)

    Sanchez-Marquez, A.; Gil-Garcia, M.; Valls, C.; Narvaez-Garcia, J.; Andia-Navarro, E.; Pozuelo-Segura, O.; Portabella-Blavia, F.

    1999-01-01

    Sports-related injuries of the lower extremity are frequent. Before magnetic resonance (MR) imaging was available, ultrasound, radionuclide scintigraphy and computed tomography were used to evaluate muscle trauma. Although relatively inexpensive, these imaging modalities are limited by their low specificity. The high degree of soft tissue contrast and multiplanar capability of MR imaging, allow direct visualization as well as characterization of traumatic muscle lesions. This pictorial review highlights the spectrum of traumatic muscle lesions on MRI, with emphasis on its typical appearances. (orig.)

  12. Proof Problems with Diagrams: An Opportunity for Experiencing Proofs and Refutations

    Science.gov (United States)

    Komatsu, Kotaro; Tsujiyama, Yosuke; Sakamaki, Aruta; Koike, Norio

    2014-01-01

    It has become gradually accepted that proof and proving are essential at all grades of mathematical learning. Among the various aspects of proof and proving, this study addresses proofs and refutations described by Lakatos, in particular a part of increasing content by deductive guessing, to introduce an authentic process into mathematics…

  13. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  14. Bone grafting via reamer-irrigator-aspirator for nonunion of open Gustilo-Anderson type III tibial fractures treated with multiplanar external fixator

    Directory of Open Access Journals (Sweden)

    Kusnezov Nicholas

    2017-01-01

    Full Text Available Introduction: The purpose of this investigation was to evaluate the outcomes following reamer-irrigator-aspirator (RIA autogenous bone grafting (ABG of high-grade open tibia fracture nonunions stabilized via multiplanar external fixation. Methods: We retrospectively reviewed all patients with Gustilo-Anderson type III open tibia fractures treated with multiplanar external fixation and who underwent RIA ABG for nonunion at our institutional Level 1 Trauma Center between 2008 and 2015. All patients between 15 and 65 years of age with a minimum of six-month follow-up were included. The primary outcomes of interest were achievement of union, time to union, and incidence of revision surgery. Complications and all-cause reoperation were recorded as secondary endpoints. Results: Fifteen patients met the inclusion criteria with a mean age of 41.1 ± 14.0 years. RIA ABG was harvested from the femur in all cases, with a mean volume of 34 ± 15 mL. At an average follow-up of 13.3 ± 6.8 months, all patients achieved union, including two who required repeat RIA ABG. One patient experienced a femoral shaft fracture four months following RIA that required intramedullary fixation. The average time to union was 6.0 ± 6.3 months. Twelve patients (80% went on to union within six months and 13 (86.7% within one year. Five patients experienced a total of six post-operative complications including three deep infections, one refracture through the nonunion site, and one gradual varus deformity. Two patients in this series required a subsequent RIA autografting procedure secondary to persistent nonunion despite initial RIA. Conclusion: We found that RIA ABG offered a reliable solution to nonunion of Gustilo-Anderson type III open tibial fractures treated with multiplanar external fixation, circumventing the need to change the method of fixation.

  15. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  16. A PROOF Analysis Framework

    International Nuclear Information System (INIS)

    González Caballero, I; Cuesta Noriega, A; Rodríguez Marrero, A; Fernández del Castillo, E

    2012-01-01

    The analysis of the complex LHC data usually follows a standard path that aims at minimizing not only the amount of data but also the number of observables used. After a number of steps of slimming and skimming the data, the remaining few terabytes of ROOT files hold a selection of the events and a flat structure for the variables needed that can be more easily inspected and traversed in the final stages of the analysis. PROOF arises at this point as an efficient mechanism to distribute the analysis load by taking advantage of all the cores in modern CPUs through PROOF Lite, or by using PROOF Cluster or PROOF on Demand tools to build dynamic PROOF cluster on computing facilities with spare CPUs. However using PROOF at the level required for a serious analysis introduces some difficulties that may scare new adopters. We have developed the PROOF Analysis Framework (PAF) to facilitate the development of new analysis by uniformly exposing the PROOF related configurations across technologies and by taking care of the routine tasks as much as possible. We describe the details of the PAF implementation as well as how we succeeded in engaging a group of CMS physicists to use PAF as their daily analysis framework.

  17. Bistatic SAR: Proof of Concept.

    Energy Technology Data Exchange (ETDEWEB)

    Yocky, David A.; Doren, Neall E.; Bacon, Terry A.; Wahl, Daniel E.; Eichel, Paul H.; Jakowatz, Charles V,; Delaplain, Gilbert G.; Dubbert, Dale F.; Tise, Bertice L.; White, Kyle R.

    2014-10-01

    Typical synthetic aperture RADAR (SAR) imaging employs a co-located RADAR transmitter and receiver. Bistatic SAR imaging separates the transmitter and receiver locations. A bistatic SAR configuration allows for the transmitter and receiver(s) to be in a variety of geometric alignments. Sandia National Laboratories (SNL) / New Mexico proposed the deployment of a ground-based RADAR receiver. This RADAR receiver was coupled with the capability of digitizing and recording the signal collected. SNL proposed the possibility of creating an image of targets the illuminating SAR observes. This document describes the developed hardware, software, bistatic SAR configuration, and its deployment to test the concept of a ground-based bistatic SAR. In the proof-of-concept experiments herein, the RADAR transmitter will be a commercial SAR satellite and the RADAR receiver will be deployed at ground level, observing and capturing RADAR ground/targets illuminated by the satellite system.

  18. Magnetic resonance imaging of the elbow. Part I: Normal anatomy, imaging technique, and osseous abnormalities

    International Nuclear Information System (INIS)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew

    2004-01-01

    Part I of this comprehensive review on magnetic resonance imaging of the elbow discusses normal elbow anatomy and the technical factors involved in obtaining high-quality magnetic resonance images of the elbow. Part I also discusses the role of magnetic resonance imaging in evaluating patients with osseous abnormalities of the elbow. With proper patient positioning and imaging technique, magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the osseous structures of the elbow. Magnetic resonance imaging can detect early osteochondritis dissecans of the capitellum and can be used to evaluate the size, location, stability, and viability of the osteochondritis dissecans fragment. Magnetic resonance imaging can detect early stress injury to the proximal ulna in athletes. Magnetic resonance imaging can detect radiographically occult fractures of the elbow in both children and adults. Magnetic resonance imaging is also useful in children to further evaluate elbow fractures which are detected on plain-film radiographs. (orig.)

  19. Dynamic Neuromuscular Control of the Lower Limbs in Response to Unexpected Single-Planar versus Multi-Planar Support Perturbations in Young, Active Adults.

    Science.gov (United States)

    Malfait, Bart; Staes, Filip; de Vries, Aijse; Smeets, Annemie; Hawken, Malcolm; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine

    2015-01-01

    An anterior cruciate ligament (ACL) injury involves a multi-planar injury mechanism. Nevertheless, unexpected multi-planar perturbations have not been used to screen athletes in the context of ACL injury prevention yet could reveal those more at risk. The objective of this study was to compare neuromuscular responses to multi-planar (MPP) and single-planar perturbations (SPP) during a stepping-down task. These results might serve as a basis for future implementation of external perturbations in ACL injury screening programs. Thirteen young adults performed a single leg stepping-down task in eight conditions (four MPP and four SPP with a specified amplitude and velocity). The amplitudes of vastus lateralis (VL), vastus medialis (VM), hamstrings lateralis (HL), hamstrings medialis (HM) EMG activity, medio-lateral and anterior-posterior centre of mass (COM) displacements, the peak knee flexion and abduction angles were compared between conditions using an one-way ANOVA. Number of stepping responses were monitored during all conditions. Significantly greater muscle activity levels were found in response to the more challenging MPP and SPP compared to the less challenging conditions (p neuromuscular activity were found between the MPP conditions and their equivalents in the SPP. Eighteen stepping responses were monitored in the SPP versus nine in the MPP indicating that the overall neuromuscular control was even more challenged during the SPP which was supported by greater COM displacements in the SPP. The more intense MPP and SPP evoked different neuromuscular responses resulting in greater muscle activity levels compared to small perturbations. Based on the results of COM displacements and based on the amount of stepping responses, dynamic neuromuscular control of the knee joint appeared less challenged during the MPP. Therefore, future work should investigate extensively if other neuromuscular differences (i.e. co-activation patterns and kinetics) exist between MPP

  20. Advances in proof theory

    CERN Document Server

    Strahm, Thomas; Studer, Thomas

    2016-01-01

    The aim of this volume is to collect original contributions by the best specialists from the area of proof theory, constructivity, and computation and discuss recent trends and results in these areas. Some emphasis will be put on ordinal analysis, reductive proof theory, explicit mathematics and type-theoretic formalisms, and abstract computations. The volume is dedicated to the 60th birthday of Professor Gerhard Jäger, who has been instrumental in shaping and promoting logic in Switzerland for the last 25 years. It comprises contributions from the symposium “Advances in Proof Theory”, which was held in Bern in December 2013. Proof theory came into being in the twenties of the last century, when it was inaugurated by David Hilbert in order to secure the foundations of mathematics. It was substantially influenced by Gödel's famous incompleteness theorems of 1930 and Gentzen's new consistency proof for the axiom system of first order number theory in 1936. Today, proof theory is a well-established branch ...

  1. Proof Nets for Lambek Calculus

    NARCIS (Netherlands)

    Roorda, Dirk

    1992-01-01

    The proof nets of linear logic are adapted to the non-commutative Lambek calculus. A different criterion for soundness of proof nets is given, which gives rise to new algorithms for proof search. The order sensitiveness of the Lambek calculus is reflected by the planarity condition on proof nets;

  2. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    International Nuclear Information System (INIS)

    Hosoya, T.; Adachi, M.; Sugai, Y.; Yamaguchi, K.; Yamaguchi, K.; Kato, T.

    2001-01-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  3. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, T.; Adachi, M.; Sugai, Y. [Dept. of Radiology, Yamagata University School of Medicine (Japan); Yamaguchi, K.; Yamaguchi, K. [Dept. of Ophthalmology, Yamagata University School of Medicine (Japan); Kato, T. [3. Dept. of Internal Medicine, Yamagata University School of Medicine (Japan)

    2001-04-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  4. Usefulness of MPR images of nephrogram in ureteropelvic junction stenosis

    International Nuclear Information System (INIS)

    Usui, Nobutaka; Munechika, Hirotsugu

    2005-01-01

    The study was to see if the multi-planar reconstruction (MPR) images of nephrogram were useful to evaluate the causative lesion of ureteropelvic junction (UPJ) stenosis. Thirty-two cases with UPJ stenosis were selected retrospectively for evaluation. MPR images were compared between nephrogram and ureterogram to see which was more useful for evaluation of the causative lesion. Most of the lesions were evaluated better in nephrogram or equal to ureterogram except for one case of a small ureteral tumor. MPR images in nephrogram were useful for evaluation of crossing vessels and a ureteral tumor. Benign stricture and calculi were also confirmed by the images. (author)

  5. Prospective Teachers' Conceptions of Proof Comprehension: Revisiting a Proof of the Pythagorean Theorem

    Science.gov (United States)

    Zazkis, Dov; Zazkis, Rina

    2016-01-01

    A significant body of research literature in mathematics education attends to mathematical proofs. However, scant research attends to proof comprehension, which is the focus of this study. We examine perspective secondary teachers' conceptions of what constitutes comprehension of a given proof and their ideas of how students' comprehension can be…

  6. Proofs, Upside Down

    DEFF Research Database (Denmark)

    Puech, Matthias

    2013-01-01

    this correspondence by applying a series of off-the-shelf program transformations à la Danvy et al. on a type checker for the bidirectional λ-calculus, and get a type checker for the λ¯ -calculus, the proof term assignment of LJT. This functional correspondence revisits the relationship between natural deduction......It is well known in proof theory that sequent-calculus proofs differ from natural deduction proofs by “reversing” elimination rules upside down into left introduction rules. It is also well known that to each recursive, functional program corresponds an equivalent iterative, accumulator......-passing program, where the accumulator stores the continuation of the iteration, in “reversed” order. Here, we compose these remarks and show that a restriction of the intuitionistic sequent calculus, LJT, is exactly an accumulator-passing version of intuitionistic natural deduction NJ. More precisely, we obtain...

  7. Tamper proofing of safeguards monitors

    International Nuclear Information System (INIS)

    Riley, R.J.

    1982-11-01

    The tamper proofing of safeguards monitors is essential if the data they produce is, and can be seen to be, reliable. This report discusses the problem of tamper proofing and gives guidance on when and how to apply tamper proofing techniques. The report is split into two parts. The first concerns the fundamental problem of how much tamper proofing to apply and the second describes methods of tamper proofing and discusses their usefulness. Both sections are applicable to all safeguards monitors although particular reference will be made to doorway monitors in some cases. The phrase 'tamper proofing' is somewhat misleading as it is impossible to completely tamper proof any device. Given enough time and resources, even the most elaborate tamper proofing can be overcome. In safeguards applications we are more interested in making the device tamper resistant and tamper indicating. That is, it should be able to resist a certain amount of tampering, and if tampering proves successful, that fact should be immediately obvious. Techniques of making a device tamper indicating and tamper resistant will be described below. The phrase tamper proofing will be used throughout this report as a generic term, including both tamper resistance and tamper indicating. (author)

  8. Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation

    DEFF Research Database (Denmark)

    Hellebust, Taran Paulsen; Tanderup, Kari; Bergstrand, Eva Stabell

    2007-01-01

    in multiplanar reconstructed images (MPR) and (3) library plans, using pre-defined applicator geometry (LIB). The doses to the lead pellets were calculated. The relative standard deviation (SD) for all reconstruction methods was less than 3.7% in the dose points. The relative SD for the LIB method...

  9. Proof patterns

    CERN Document Server

    Joshi, Mark

    2015-01-01

    This innovative textbook introduces a new pattern-based approach to learning proof methods in the mathematical sciences. Readers will discover techniques that will enable them to learn new proofs across different areas of pure mathematics with ease. The patterns in proofs from diverse fields such as algebra, analysis, topology and number theory are explored. Specific topics examined include game theory, combinatorics, and Euclidean geometry, enabling a broad familiarity. The author, an experienced lecturer and researcher renowned for his innovative view and intuitive style, illuminates a wide range of techniques and examples from duplicating the cube to triangulating polygons to the infinitude of primes to the fundamental theorem of algebra. Intended as a companion for undergraduate students, this text is an essential addition to every aspiring mathematician’s toolkit.

  10. Computed tomography imaging for superior semicircular canal dehiscence syndrome

    International Nuclear Information System (INIS)

    Dobeli, Karen

    2006-01-01

    Superior semicircular canal dehiscence is a newly described syndrome of sound and/or pressure induced vertigo. Computed tomography (CT) imaging plays an important role in confirmation of a defect in the bone overlying the canal. A high resolution CT technique utilising 0.5 mm or thinner slices and multi-planar reconstructions parallel to the superior semicircular canal is required. Placement of a histogram over a suspected defect can assist CT diagnosis

  11. Final report SmartProofS. Results of projects of the SmartProofS program; Eindrapport SmartProofS. Projectresultaten van het SmartProofS programma

    Energy Technology Data Exchange (ETDEWEB)

    Van Hoorik, P.; Westerga, R. [Energy Valley, Groningen (Netherlands)

    2011-05-15

    The SmartProofs program aims to develop tools which must show that the principle of a Smart Power System (SPS) works and how. An SPS can ensure that the supply and demand of electricity in the grid is balanced, even in case more decentralized energy techniques will be put into use. This final report summarizes the main results and conclusions of the SmartProofs program. As part of the SPS program attention is paid to the impacts on the girds, the effects of centralized and decentralized management, disaster resilience, pricing models, potential benefits of control and new business models [Dutch] Het SmartProofs programma heeft tot doel om een concept van een Smart Power System (SPS) te ontwikkelen waarmee kan worden aangetoond dat het principe van een SPS werkt en op welke manier. Een SPS kan zorgen dat het aanbod van elektriciteit op het net op elk moment van de dag overeenkomt met de vraag, ook als er straks veel meer decentrale energietechnieken gebruikt worden waarmee zowel de vraag als het aanbod van elektriciteit onvoorspelbaar wordt. Dit eindrapport geeft een overzicht van de belangrijkste resultaten en conclusies van het SmartProofs programma. Het programma heeft in de werkpakketten deelvraagstukken rondom SmartProofS onderzocht rondom de effecten op onze energienetten, de effecten van zowel centrale- als decentrale aansturing, disaster resilience, prijsmodellen, mogelijke baten van aansturing en nieuwe business modellen.

  12. PROOF on a Batch System

    International Nuclear Information System (INIS)

    Behrenhoff, W; Ehrenfeld, W; Samson, J; Stadie, H

    2011-01-01

    The 'parallel ROOT facility' (PROOF) from the ROOT framework provides a mechanism to distribute the load of interactive and non-interactive ROOT sessions on a set of worker nodes optimising the overall execution time. While PROOF is designed to work on a dedicated PROOF cluster, the benefits of PROOF can also be used on top of another batch scheduling system with the help of temporary per user PROOF clusters. We will present a lightweight tool which starts a temporary PROOF cluster on a SGE based batch cluster or, via a plugin mechanism, e.g. on a set of bare desktops via ssh. Further, we will present the result of benchmarks which compare the data throughput for different data storage back ends available at the German National Analysis Facility (NAF) at DESY.

  13. Diagnostic imaging in undergraduate medical education: an expanding role

    International Nuclear Information System (INIS)

    Miles, K.A.

    2005-01-01

    Radiologists have been involved in anatomy instruction for medical students for decades. However, recent technical advances in radiology, such as multiplanar imaging, 'virtual endoscopy', functional and molecular imaging, and spectroscopy, offer new ways in which to use imaging for teaching basic sciences to medical students. The broad dissemination of picture archiving and communications systems is making such images readily available to medical schools, providing new opportunities for the incorporation of diagnostic imaging into the undergraduate medical curriculum. Current reforms in the medical curriculum and the establishment of new medical schools in the UK further underline the prospects for an expanding role for imaging in medical education. This article reviews the methods by which diagnostic imaging can be used to support the learning of anatomy and other basic sciences

  14. Lakatos and Hersh on Mathematical Proof

    Directory of Open Access Journals (Sweden)

    Hossein Bayat

    2015-12-01

    Full Text Available The concept of Mathematical Proof has been controversial for the past few decades. Different philosophers have offered different theories about the nature of Mathematical Proof, among which theories presented by Lakatos and Hersh have had significant similarities and differences with each other. It seems that a comparison and critical review of these two theories will lead to a better understanding of the concept of mathematical proof and will be a big step towards solving many related problems. Lakatos and Hersh argue that, firstly, “mathematical proof” has two different meanings, formal and informal; and, secondly, informal proofs are affected by human factors, such as individual decisions and collective agreements. I call these two thesis, respectively, “proof dualism” and “humanism”. But on the other hand, their theories have significant dissimilarities and are by no means equivalent. Lakatos is committed to linear proof dualism and methodological humanism, while Hersh’s theory involves some sort of parallel proof dualism and sociological humanism. According to linear proof dualism, the two main types of proofs are provided in order to achieve a common goal: incarnation of mathematical concepts and methods and truth. However, according to the parallel proof dualism, two main types of proofs are provided in order to achieve two different types of purposes: production of a valid sequence of signs (the goal of the formal proof and persuasion of the audience (the goal of the informal proof. Hersh’s humanism is informative and indicates pluralism; whereas, Lakatos’ version of humanism is normative and monistic.

  15. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  16. Simplifying the Exploration of Volumetric Images: Development of a 3D User Interface for the Radiologist’s Workplace

    OpenAIRE

    Teistler, M.; Breiman, R. S.; Lison, T.; Bott, O. J.; Pretschner, D. P.; Aziz, A.; Nowinski, W. L.

    2007-01-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented wit...

  17. Proof Auditing Formalised Mathematics

    Directory of Open Access Journals (Sweden)

    Mark Miles Adams

    2016-01-01

    Full Text Available The first three formalisations of major mathematical proofs have heralded a new age in formalised mathematics, establishing that informal proofs at the limits of what can be understood by humans can be checked by machine. However, formalisation itself can be subject to error, and yet there is currently no accepted process in checking, or even much concern that such checks have not been performed. In this paper, we motivate why we should be concerned about correctness, and argue the need for proof auditing, to rigorously and independently check a formalisation. We discuss the issues involved in performing an audit, and propose an effective and efficient auditing process. Throughout we use the Flyspeck Project, that formalises the Kepler Conjecture proof, to illustrate our point.

  18. Parasellar meningiomas: magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Santos, Alair Augusto S.M.D. dos; Fontes, Cristina Asvolinsque P.

    2001-01-01

    We reviewed 22 cases of patients with parasellar meningiomas evaluated with magnetic resonance imaging (MRI) in private clinics of the cities of Niteroi and Rio de Janeiro, Rio de Janeiro State, Brazil. Our aim was to characterize the imaging findings in this type of tumor. MRI scanners with 0.5 and 1.0 Tesla magnets were used for the acquisition of multiplanar T1-weighted (pre-and post-gadolinium administration) and T2-weighted images. The main symptoms observed were headache and visual disturbances. Hyperprolactinaemia was observed in only one patient. The most frequent imaging finding was a parasellar mass which appeared hypointense on T1-weighted and hyperintense on T2-weighted images, and enhanced intensively after gadolinium administration. MRI is useful to demonstrate the lesion and to asses the damage to adjacent structures, particularly when the patient presents visual disturbances due to involvement of the cavernous sinuses. (author)

  19. Advanced MR brain imaging. Why?

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Tekes, Aylin

    Repeated examinations, also known as so-called 'follow-up examinations' are nowadays frequently used to decide whether or not a chosen treatment should be continued, adapted or discontinued. The side effects of X-rays on biological systems, especially on developing systems did, however, limit the use of X-rays in children. The development of high-resolution, non-ionizing imaging modalities like US and MRI revolutionized diagnostic medicine for the second time after the discovery of X-rays. US is nowadays an essential imaging modality in paediatrics; it can be performed at the bedside, has no side effects on the child, is widely available, well accepted by parents and can be repeated without limitations. MRI with its high spatial resolution, different imaging contrasts and multiplanar capabilities has grown into a second line imaging modality if plain films and US cannot make the diagnosis accurately or reliably. A third revolution in diagnostic imaging occurred as MRI allowed studying biological processes and functions non-invasively. (orig.)

  20. Vaginal Masses: Magnetic Resonance Imaging Features with Pathologic Correlation

    International Nuclear Information System (INIS)

    Elsayes, K.M.; Narra, V.R.; Dillman, J.R.; Velcheti, V.; Hameed, O.; Tongdee, R.; Menias, C.O.

    2007-01-01

    The detection of vaginal lesions has increased with the expanding use of cross-sectional imaging. Magnetic resonance imaging (MRI) - with its high-contrast resolution and multiplanar capabilities - is often useful for characterizing vaginal masses. Vaginal masses can be classified as congenital, inflammatory, cystic (benign), and neoplastic (benign or malignant) in etiology. Recognition of the typical MR imaging features of such lesions is important because it often determines the treatment approach and may obviate surgery. Finally, vaginal MR imaging can be used to evaluate post-treatment changes related to previous surgery and radiation therapy. In this article, we will review pertinent vaginal anatomy, vaginal and pelvic MRI technique, and the MRI features of a variety of vaginal lesions with pathological correlation

  1. Multiflash X ray with Image Detanglement for Single Image Isolation

    Science.gov (United States)

    2017-08-31

    known and separated into individual images. A proof-of- principle study was performed using 4 X-ray flashes and copper masks with sub-millimeter holes...Popular Science article.2 For decades, that basic concept dominated the color television market . Those were the days when a large color television...proof-of- principle study was performed using 4 X-ray flashes and copper masks with sub-millimeter holes that allowed development of the required image

  2. MR imaging of the pediatric spine: Comparison of myelography, MCT, and surgery

    International Nuclear Information System (INIS)

    Davis, P.C.; Hoffman, J.C.; Ball, T.I.; Wyly, J.B.; Braun, I.F.; Fry, S.M.

    1986-01-01

    Results of MR imaging of 53 pediatric patients with suspected spinal abnormalities were compared findings on metrizamide myelography, MCT, and surgery. Prototype surface coil studies with multisection multiplanar imaging (0.5 and 1.5 T) using T1-weighted sequences were optimum for anatomic definition, while T2-weighted sequences were utilized for intramedullary pathology. Diseases studied included neoplasia, infection, trauma, scoliosis, and dysrhaphsium. Surface coils were essential for imaging the thoracic and lumbar spine. MR imaging yielded approximately equivalent information to that obtained on myelography or MCT in 25 of 31 patients. Limitations to MR imaging included bony spurs, small eccentric lesions, tumor seeding, metal artifacts, postoperative scarring, and motion. With further refinements, MR imaging may replace more invasive techniques for pediatric spinal imaging

  3. The contribution of high-resolution multiplanar reformats of the skull base to the detection of skull-base fractures

    International Nuclear Information System (INIS)

    Connor, S.E.J.; Flis, C.

    2005-01-01

    AIM: To investigate the contribution of routine review of submillimetric multiplanar reformats to the diagnosis of skull-base fractures. METHODS: A prospective analysis was performed of 407 cases referred over a 6-month period for CT of the skull following cranial trauma. The reformatted 5-mm axial sections and subsequently the high-resolution multiplanar reformats (HRMPRs) were viewed on an ADW 4.1 workstation using bone windows and algorithm. All skull-base fractures and related features, recorded by the consensus of two radiologists, were classified as anatomically significant or non-significant on the basis of eight criteria. The clinical features of skull-base injury and any subsequent treatment were noted in all cases of skull-base fracture. RESULTS: HRMPRs detected 80 separate skull-base fractures in 36/407 cases. Of these 80 fractures, 57 were visible on 5-mm axial sections. In 8 of the 36 cases, the significant anatomical features were only evident on review of the HRMPRs. In 6 of the 36 cases, none of the skull-base fractures was visible on 5-mm sections, but these individuals had only minor associated clinical features and no therapeutic requirements. Review of HRMPRs could have been confined to patients with skull-base fractures, abnormal intracranial and extracranial air collections or opacified mastoid air cells revealed by 5-mm axial sections. This policy would have led to the detection of 79/80 (99%) of skull-base fractures and all significant anatomical features. CONCLUSION: The 5-mm axial sections demonstrated 71% of skull-base fractures and 78% of skull-base fractures with significant anatomical features, using HRMPRs as a gold standard. There were no significant clinical sequelae at short-term follow-up of those fractures only evident on HRMPRs

  4. Flood-proof motors

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Marcus [AREVA NP GmbH, Erlangen (Germany)

    2013-07-01

    Even before the Fukushima event occurred some German nuclear power plants (NPP) have considered flooding scenarios. As a result of one of these studies, AREVA performed an upgrade project in NPP Isar 1 with flood-proof motors as a replacement of existing air-cooled low-voltage and high-voltage motors of the emergency cooling chain. After the Fukushima event, in which the cooling chains failed, the topic flood-proof equipment gets more and more into focus. This compact will introduce different kinds of flood-proof electrical motors which are currently installed or planned for installation into NPPs over the world. Moreover the process of qualification, as it was performed during the project in NPP Isar 1, will be shown. (orig.)

  5. Flood-proof motors

    International Nuclear Information System (INIS)

    Schmitt, Marcus

    2013-01-01

    Even before the Fukushima event occurred some German nuclear power plants (NPP) have considered flooding scenarios. As a result of one of these studies, AREVA performed an upgrade project in NPP Isar 1 with flood-proof motors as a replacement of existing air-cooled low-voltage and high-voltage motors of the emergency cooling chain. After the Fukushima event, in which the cooling chains failed, the topic flood-proof equipment gets more and more into focus. This compact will introduce different kinds of flood-proof electrical motors which are currently installed or planned for installation into NPPs over the world. Moreover the process of qualification, as it was performed during the project in NPP Isar 1, will be shown. (orig.)

  6. Algebraic proofs over noncommutative formulas

    Czech Academy of Sciences Publication Activity Database

    Tzameret, Iddo

    2011-01-01

    Roč. 209, č. 10 (2011), s. 1269-1292 ISSN 0890-5401 R&D Projects: GA MŠk LC505 Institutional research plan: CEZ:AV0Z10190503 Keywords : proof complexity * algebraic proof system s * frege proofs Subject RIV: BA - General Mathematics Impact factor: 0.560, year: 2011 http://www.sciencedirect.com/science/article/pii/S089054011100109X

  7. MR imaging of oropharynx and oral cavity

    International Nuclear Information System (INIS)

    Vogl, T.; Markl, A.F.; Bruning, R.; Greves, G.; Kang, K.; Lissner, J.A.

    1988-01-01

    The effect of intravenously administered Gd-DTPA on signal intensity, in the oropharynx and oral cavity was analyzed, in comparison with plain imaging the examinations were carried out on 150 patients, with a 1.5-T magnetic resonance (MR) imaging unit. During and after the application of Gd-DTPA, flash images with a repetition time of 30, an echo time of 12 msec, and a 20 0 flip angle were acquired over a period of 7 minutes. In 89 patients, malignant tumors were discovered, located primarily in the oropharynx and oral cavity. Plain MR imaging was equal to or better than computed tomograph in all patients except five. Marked contrast enhancement was observed in carcinomas, sarcomas, and inflammation. The enhancement of signal intensity versus time allowed a better differentiation of histologic features. MR imaging contributes substantially to the imaging of the oropharynx and oral cavity by improved soft-tissue contrast and the capacity for multiplanar imaging

  8. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    Science.gov (United States)

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter  10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  9. Imaging in the diagnosis of juvenile nasopharyngeal angiofibroma

    Directory of Open Access Journals (Sweden)

    Satyaranjan Mishra

    2013-01-01

    Full Text Available Juvenile nasopharyngeal angiofibroma (JNA is a rare, benign, highly vascular, and locally aggressive tumor that predominantly occurs in adolescent males. Usually, the presenting symptom is a painless nasal obstruction or epistaxis; however, other symptoms may develop depending on the size and extent of the tumor mass. Owing to the vascularity of the tumor, incisional biopsy is not attempted. The diagnosis is dependent on multiplanar imaging modalities like Computed Tomography (CT, Magnetic Resonance Imaging (MRI, and Angiography. These imaging modalities help in assessing the tumor mass, pre-operative embolization of the feeder vessel, and treatment planning. Usually, patients with JNA are diagnosed by otorhinolaryngologists, but here, we present a rare case of JNA reporting to the dental hospital due to a tender palatal swelling.

  10. Magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Kulkarni, M.V.

    1986-01-01

    MRI of the abdomen currently competes with CT and ultrasonography as an imaging technique for abdominal pathology. Although ultrasonography has certain advantages, such as real-time scanning, the major comparison is to be made between MR and CT. CT has slightly superior spatial resolution and minimal motion artifacts, and enables the use of contrast agents in bowel. MR, on the other hand, has improved capabilities in contrasting soft tissues and providing multiplanar imaging. The greatest advantage of CT is the experience that the medical community has gained with it over the last decade. Further development in technology and improvement in the clinical experience with MR will be important in determining its future role in abdominal imaging. Large series of clinical trials are required for further experience. Chemical spectroscopy with proton and possibly other nuclei may improve diagnostic specificity. Paramagnetic contrast agents for bowel specification would certainly improve imaging quality. Thus, MR will play a significant role in abdominal imaging in the future

  11. Three-dimensional isotropic fat-suppressed proton density-weighted MRI at 3 tesla using a T/R-coil can replace multiple plane two-dimensional sequences in knee imaging

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A. [Bonn Univ. (Germany). Dept. of Radiology; Gieseke, J. [Philips Healthcare, Hamburg (Germany); and others

    2016-10-15

    To evaluate whether a 3D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9±14.5 years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40-0.63 x 0.44-0.89 x 3 mm{sup 3}) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 x 0.68 x 0.63 mm{sup 3}). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p<0.01 for ACL and PCL; p=0.07 for MEN). Compared to 2D images, the OIQ was rated higher in 3D-PDwFS images (p<0.01) due to fewer artifacts and HFS despite the lower IS (p<0.01). The sensitivity and specificity of lesion detection in 3D- and 2D-PDwFS were similar. Compared to standard multiplanar 2D-PDwFS knee imaging, isotropic high spatial resolution 3D-PDwFS of the knee at 3.0T can be acquired with high image quality in a reasonable scan time. Multiplanar reformations in arbitrary planes may serve as an additional benefit of 3D-PDwFS.

  12. Proof assistants: History, ideas and future

    Indian Academy of Sciences (India)

    application is and will be in computer supported modelling and verification of sys- tems. But there is still ... Introduction ... compute with them, but their main focus is on doing proofs. ..... Proof development in a type theory based proof assistant.

  13. Diagnostic imaging of injuries and overuse in soccer players

    International Nuclear Information System (INIS)

    Jonge, M.C. de; Maas, M.; Kuijk, C. van

    2002-01-01

    Soccer is one of the most popular sports worldwide. There is a high incidence of injuries in soccer in which several intrinsic and extrinsic factors play a part. Most injuries are minor, self-limiting and do not need extensive medical treatment or imaging. Imaging can be required for several reasons e.g. when the clinical findings are doubtful, to replace arthroscopy (i. e. of the knee) or for prognostic reasons. All imaging modalities available to the radiologist can be used but MRI is the most valuable imaging modality with its superior contrast resolution and multiplanar capabilities. Basically, injuries in the soccer player can occur anywhere in the body like in every sport. The lower extremities, more specific the knee and ankle, are however the most injured parts. (orig.) [de

  14. 46 CFR 201.144 - Offer of proof.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Offer of proof. 201.144 Section 201.144 Shipping... PROCEDURE Evidence (Rule 14) § 201.144 Offer of proof. An offer of proof made in connection with an... accompany the record as the offer of proof. ...

  15. Postoperative imaging of paranasal sinuses

    International Nuclear Information System (INIS)

    Nemec, S.; Czerny, C.; Formanek, M.

    2007-01-01

    The radiological interpretation of postoperative changes of the paranasal sinuses requires knowledge of why and how the surgical intervention was performed and what the basic clinical findings were. It is important to know whether there was an inflammation, a reconstructive procedure, or a tumorous process. Multidetector computed tomography (MDCT) evaluated in a high-resolution bone window level setting represents the method of choice for imaging after nonfunctional and functional procedures after inflammatory changes as well as for imaging after reconstructive surgery because of facial trauma or before dental implantation. In the postoperative follow-up of tumor patients contrast-enhanced MDCT evaluated in a soft tissue window and bone window and especially magnetic resonance imaging (MRI) represent the standard. In many cases it is possible to differentiate tumor recurrence from inflammation with the help of contrast-enhanced multiplanar MRI and to detect bone marrow changes prior to CT. (orig.)

  16. Multiplanar lumbopelvic control in patients with low back pain: is multiplanar assessment better than single plane assessment in discriminating between patients and healthy controls?

    Science.gov (United States)

    Nelson-Wong, E; Gallant, P; Alexander, S; Dehmer, K; Ingvalson, S; McClenahan, B; Piatte, A; Poupore, K; Davis, A M

    2016-02-01

    Patients with low back pain (LBP) commonly have lumbopelvic control deficits. Lumbopelvic assessment during sagittal motion is incorporated into commonly used clinical examination algorithms for Treatment Based Classification. The purpose of this study was to investigate whether combined assessment of lumbopelvic control during sagittal and frontal plane motion discriminates between people with and without LBP better than single plane assessment alone. Nineteen patients with LBP and 18 healthy control participants volunteered for this study. The active straight leg raise (ASLR) and active hip abduction (AHAbd) tests were used to assess lumbopelvic control during sagittal and frontal plane motion, respectively. The tests were scored as positive or negative using published scoring criteria. Contingency tables were created for each test alone and for the combined tests (both positive/both negative) with presence/absence of LBP as the reference standard to calculate accuracy statistics of sensitivity (sn), specificity (sp), likelihood (+LR and -LR), and diagnostic odds ratios (OR). Active straight leg raise and AHAbd tests alone had sn of 0·63, 0·74, respectively, sp of 0·61, 0·50, respectively, and OR of 2·7, 2·8, respectively. The combined tests had sn = 0·89, sp = 0·60, and OR = 12·0. Forty percent of patients with LBP had control deficits in both planes of motion. The AHAbd and ALSR tests appear to have greater diagnostic discrimination when used in combination than when used independently. A percentage of patients with LBP had control deficits in both planes, while others demonstrated uniplanar deficits only. These findings highlight the importance of multiplanar assessment in patients with LBP.

  17. Anatomic Illustrations of Cranial Ultrasound Images Obtained Through the Mastoid Fontanelle in Neonates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Man; Lee, Young Seok [Dankook University Hospital, Cheonan (Korea, Republic of)

    2011-09-15

    Neonatal cranial sonography performed through the mastoid fontanelle is more useful to evaluate the peripheral structures at the convexity of the cerebral hemispheres and brainstem rather than that performed through the anterior fontanelle. The purpose of this study is to demonstrate the anatomy of the extracerebral CSF space and brainstem and to suggest appropriate scan planes for performing neonatal cranial sonography through the mastoid fontanelle using MRI and multiplanar reconstruction programs. A neonate with normal features on ultrasonography and good image quality on MRI, including the 3D-SPGR axial scans, was selected. We made the reconstructed MR images corresponding to the sonongraphic planes and the anatomic models of the neonatal cranial sonographic images by using axial MRI as the standard reference on the same screen. We demonstrated the sonographic images at the levels of the body of the caudate nucleus and lentiform nucleus, the head of the caudate nucleus and thalamus, the third ventricle and midbrain, and the midbrain and cerebellar vermis on the oblique axial scans. Four oblique coronal images at the levels of the periventricular white matter, basal ganglia, thalamus and tentorium were also obtained. We illustrated the anatomic atlas with including four oblique axial scans and four oblique coronal scans that corresponded to the neonatal cranial sonographic images through the mastoid fontanelle. We objectively analyzed the anatomy of the extracerebral CSF space and brainstem by using MRI and multiplanar reconstruction programs and we provided the standardized sonographic scan planes through the mastoid fontanelle. This study will be very helpful for evaluating the abnormalities of the peripheral structures at the convexity of the cerebral hemispheres and brainstem

  18. Quantitative assessment of gas cell development during the proofing of dough by magnetic resonance imaging and image analysis

    NARCIS (Netherlands)

    Duynhoven, van J.P.M.; Kempen, van G.M.P.; Sluis, van R.; Rieger, B.; Weegels, P.; Vliet, van L.J.; Nicolaij, K.

    2003-01-01

    The structure of bread crumb is an important factor in consumer acceptance of bakery products. The noninvasive monitoring of the gas cell formation during the proofing of dough can aid in understanding the mechanisms governing the crumb appearance in the baked product. The development of gas cells

  19. Postoperative evaluation after anterior cruciate ligament reconstruction: Measurements and abnormalities on radiographic and CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Cheol; Choi, Yun Sun; KIm, Hyoung Seop; Choi, Nam Hong [Nowon Eulji Medical Center, Eulji University, Seoul (Korea, Republic of)

    2016-11-15

    Reconstruction of a ruptured anterior cruciate ligament (ACL) is a well-established procedure for repair of ACL injury. Despite improvement of surgical and rehabilitation techniques over the past decades, up to 25% of patients still fail to regain satisfactory function after an ACL reconstruction. With development of CT imaging techniques for reducing metal artifacts, multi-planar reconstruction, and three-dimensional reconstruction, early post-operative imaging is increasingly being used to provide immediate feedback to surgeons regarding tunnel positioning, fixation, and device placement. Early post-operative radiography and CT imaging are easy to perform and serve as the baseline examinations for future reference.

  20. The value of multislice helical CT in the diagnosis of the rib micro-fracture

    International Nuclear Information System (INIS)

    Wang Shuli; Wang Linsen; Sun Dingyuan; Deng Xin; Geng Xin; Li Jian; Liu Zhigang; Guo Lin; Jia Zhihong

    2005-01-01

    Objective: To evaluate the clinical value of MSCT with thin-section reconstruction and curved multiplanar reformation of rib micro-fracture. Methods: Thirty-eight patients suspected ribs fracture by clinical examination, which had negative appearance in X-ray film, were performed with MSCT scan with thin-section reconstructed and curved multiplanar reformation. The imaging of 5 mm, 1 mm thickness and curved reformatted imags were analysed by three groups of radiologists respectively. Results: Of the 38 patients, 26 patients were demonstrated ribs fracture with 1 mm thin-section reconstructed and curved multiplanar reformatted CT imaging, which were classified as complete fracture in 18 ribs and incomplete fracture in 41 ribs. The ends of the fractures displacement located within a distance of double-thickness of the cortex of the complete ribs fracture. With 5 mm thickness imaging, the accuracy of the diagnosis was 86.4%, 89.8% and 94.9% by three groups radiologists, respectively. Conclusion: The rib fracture is very common in clinic, the incomplete and non evident displacement complete ribs fracture are difficult to be diagnosed by plain radiography. The MSCT can produce a large range volume information scan. Thin-section reconstructed and curved multiplanar reformatted imaging should be the effective method in diagnosis of ribs fracture. The total rib pattern and location, extend of all the ribs fracture in this cases can be displayed in one scan by the curved multiplanar reformatted imaging. (authors)

  1. 45 CFR 81.85 - Offer of proof.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Offer of proof. 81.85 Section 81.85 Public Welfare... 80 OF THIS TITLE Hearing Procedures § 81.85 Offer of proof. An offer of proof made in connection with... identification and shall accompany the record as the offer of proof. ...

  2. Magnetic resonance imaging (MRI) of the renal sinus.

    Science.gov (United States)

    Krishna, Satheesh; Schieda, Nicola; Flood, Trevor A; Shanbhogue, Alampady Krishna; Ramanathan, Subramaniyan; Siegelman, Evan

    2018-04-09

    This article presents methods to improve MR imaging approach of disorders of the renal sinus which are relatively uncommon and can be technically challenging. Multi-planar Single-shot T2-weighted (T2W) Fast Spin-Echo sequences are recommended to optimally assess anatomic relations of disease. Multi-planar 3D-T1W Gradient Recalled Echo imaging before and after Gadolinium administration depicts the presence and type of enhancement and relation to arterial, venous, and collecting system structures. To improve urographic phase MRI, concentrated Gadolinium in the collecting systems should be diluted. Diffusion-Weighted Imaging (DWI) should be performed before Gadolinium administration to minimize T2* effects. Renal sinus cysts are common but can occasionally be confused for dilated collecting system or calyceal diverticula, with the latter communicating with the collecting system and filling on urographic phase imaging. Vascular lesions (e.g., aneurysm, fistulas) may mimic cystic (or solid) lesions on non-enhanced MRI but can be suspected by noting similar signal intensity to the blood pool and diagnosis can be confirmed with MR angiogram/venogram. Multilocular cystic nephroma commonly extends to the renal sinus, however, to date are indistinguishable from cystic renal cell carcinoma (RCC). Solid hilar tumors are most commonly RCC and urothelial cell carcinoma (UCC). Hilar RCC are heterogeneous, hypervascular with epicenter in the renal cortex compared to UCC which are centered in the collecting system, homogeneously hypovascular, and show profound restricted diffusion. Diagnosis of renal sinus invasion in RCC is critically important as it is the most common imaging cause of pre-operative under-staging of disease. Fat is a normal component of the renal sinus; however, amount of sinus fat correlates with cardiovascular disease and is also seen in lipomatosis. Fat-containing hilar lesions include lipomas, angiomyolipomas, and less commonly other tumors which engulf sinus

  3. Introduction to proof in abstract mathematics

    CERN Document Server

    Wohlgemuth, Andrew

    2011-01-01

    The primary purpose of this undergraduate text is to teach students to do mathematical proofs. It enables readers to recognize the elements that constitute an acceptable proof, and it develops their ability to do proofs of routine problems as well as those requiring creative insights. The self-contained treatment features many exercises, problems, and selected answers, including worked-out solutions. Starting with sets and rules of inference, this text covers functions, relations, operation, and the integers. Additional topics include proofs in analysis, cardinality, and groups. Six appendixe

  4. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  5. Head and neck imaging with MDCT

    International Nuclear Information System (INIS)

    Imhof, H.; Czerny, Chr.; Dirisamer, A.

    2003-01-01

    Multi-slice CT (MDCT) is rapidly becoming the new standard in radiological imaging. Although its advantages in cardiovascular, thoracic and abdominal imaging are evident, the extent of its usefulness for imaging the head and neck has yet to be clarified. Because of the shorter examination time motion artifacts are reduced, phonation-studies are possible. Due to the thin-slicing and nearly isotropic multiplanar reconstruction (MPR) examination in only one plane is necessary, saving both time and radiation exposure. The shorter examination requires the use of higher concentrated contrast medium (400 mg of iodine/ml). The use of such a contrast medium produces a higher degree of contrast enhancement and provides a 5-10% higher contrast between the surrounding normal and pathological tissue, but is more time critical. MPRs are easily done in any plane within seconds and enables also three-dimensional visualization, what helps in the use of minimal invasive therapy, training and teaching and provides a way of handling the hundreds of images acquired during scanning

  6. Impact- and earthquake- proof roof structure

    International Nuclear Information System (INIS)

    Shohara, Ryoichi.

    1990-01-01

    Building roofs are constituted with roof slabs, an earthquake proof layer at the upper surface thereof and an impact proof layer made of iron-reinforced concrete disposed further thereover. Since the roofs constitute an earthquake proof structure loading building dampers on the upper surface of the slabs by the concrete layer, seismic inputs of earthquakes to the buildings can be moderated and the impact-proof layer is formed, to ensure the safety to external conditions such as earthquakes or falling accidents of airplane in important facilities such as reactor buildings. (T.M.)

  7. Diagnostic imaging of craniofacial trauma and fractures and their sequelae

    International Nuclear Information System (INIS)

    Buitrago-Tellez, C.H.; Kunz, C.

    2001-01-01

    The value and applications of the CT modalities are on the rise, particularly since the availability of spiral CT techniques, while conventional native diagnostics is increasingly used for special imaging purposes. Multiplanar spiral CT enables high-quality coronary 2D reconstructions which, in the acute phase, make redundant primary coronary imaging modalities. Exact knowledge of typical fracture patterns facilitates the analysis of images of the relevant facial areas. 3D reconstructions are indispensable in pin-pointed surgery planning, generation of stereolithographic models, and image-guided interventions for examination of post-traumatic deformities. Since a secondary correction only very rarely leads to restitutio ad integrum, it is necessary to detect the therapy-relevant injuries very early, during acute diagnostic imaging, in order to lay the basis for subsequent therapy and restoration of the craniofacial structures and functions. (orig./CB) [de

  8. MR imaging of the pediatric central nervous system utilization review

    International Nuclear Information System (INIS)

    Barnes, P.D.; Prince, J.R.; Galloway, D.C.; Ross-Duggan, J.; Lester, P.D.; Yamanashi, W.S.

    1986-01-01

    MR has been done in over 500 pediatric and adolescent patients (ages 5 days to 20 years) with central nervous system (CNS) disease (brain, n = 331; spine, n = 218), including high-field and special coil application in 362 cases. T1-weighted, multiplanar MR imaging provides superior anatomic delineation of organogenetic CNS malformations, while multiparameter (T1, T2, p) MR is usually necessary for more complete characterization of histogenetic malformations, as well as acquired conditions. MR imaging is a desirable method for the initial and definitive evaluation of many cranial and spinal conditions of childhood (more-invasive procedures were obviated in 164 patients). CT or other modalities may be added when MR imaging does not satisfy the clinical query

  9. Advanced imaging of the musculoskeletal system: Standard, three-dimensional, and contrast-enhanced CT and MR imaging, and quantitative bone densitometry

    International Nuclear Information System (INIS)

    Resnick, D.; Sartoris, D.J.

    1987-01-01

    This course reviews the application of advanced imaging techniques to a broad spectrum of musculoskeletal disorders. The indications for and utility of standard CT in both the axial and the appendicular skeleton is explored. The combined use of CT with air and contrast arthrography at sites including the hip, knee, and shoulder is discussed. A summary of the proved and potential applications of MR imaging in osseous, articular, bone marrow, and soft-tissue disorders is provided. The utility of intraarticular contrast agents in enhancing the diagnostic capabilities of MR imaging for disorders of hyaline cartilage and and fibrocartilage is demonstrated. The advantages of multiplanar reformation and three-dimensional image reconstruction of cross-sectional imaging data are described in conjunction with the fundamental technological principles of these strategies. Accepted methods as well as investigative techniques for the diagnosis and follow-up of metabolic bone disease are contrasted with regard to relative indications, advantages, and limitations

  10. ProofJudge: Automated Proof Judging Tool for Learning Mathematical Logic

    DEFF Research Database (Denmark)

    Villadsen, Jørgen

    2015-01-01

    Today we have software in many artefacts, from medical devices to cars and airplanes, and the software must not only be efficient and intelligent but also reliable and secure. Tests can show the presence of bugs but cannot guarantee their absence. A machine-checked proof using mathematical logic...... pen and paper because no adequate tool was available. The learning problem is how to make abstract concepts of logic as concrete as possible. ProofJudge is a computer system and teaching approach for teaching mathematical logic and automated reasoning which augments the e-learning tool NaDeA (Natural...

  11. ProofJudge: Automated Proof Judging Tool for Learning Mathematical Logic

    DEFF Research Database (Denmark)

    Villadsen, Jørgen

    2016-01-01

    Today we have software in many artefacts, from medical devices to cars and airplanes, and the software must not only be efficient and intelligent but also reliable and secure. Tests can show the presence of bugs but cannot guarantee their absence. A machine-checked proof using mathematical logic...... using pen and paper because no adequate tool was available. The learning problem is how to make abstract concepts of logic as concrete as possible. ProofJudge is a computer system and teaching approach for teaching mathematical logic and automated reasoning which augments the e-learning tool Na...

  12. Role of magnetic resonance imaging in patient selection for uterine artery embolization

    International Nuclear Information System (INIS)

    Cura, M.; Cura, A.; Bugnone, A.

    2006-01-01

    Uterine fibroids are common tumors of the female pelvis. Uterine artery embolization (UAE) is an effective treatment of symptomatic uterine leiomyoma in the appropriate candidates, reducing or eliminating leiomyoma-related symptoms of bleeding, bulk, and/or pain. Magnetic resonance imaging (MRI) can be used to assess women with symptoms potentially attributable to uterine leiomyomas, and help to determine who is an appropriate candidate for UAE. Because of soft tissue characterization, multiplanar imaging capabilities, and enhancement, MR imaging not only accurately detects and characterizes uterine leiomyomas but also may predict who will benefit from the embolization. MRI ability to detect coexistent uterine or pelvic pathology may change the diagnosis and treatment management of patients being evaluated for UAE

  13. Role of magnetic resonance imaging in patient selection for uterine artery embolization

    Energy Technology Data Exchange (ETDEWEB)

    Cura, M.; Cura, A.; Bugnone, A. [Univ. of Texas Health Science Center, San Antonio, TX (United States). Dept. of Radiology

    2006-12-15

    Uterine fibroids are common tumors of the female pelvis. Uterine artery embolization (UAE) is an effective treatment of symptomatic uterine leiomyoma in the appropriate candidates, reducing or eliminating leiomyoma-related symptoms of bleeding, bulk, and/or pain. Magnetic resonance imaging (MRI) can be used to assess women with symptoms potentially attributable to uterine leiomyomas, and help to determine who is an appropriate candidate for UAE. Because of soft tissue characterization, multiplanar imaging capabilities, and enhancement, MR imaging not only accurately detects and characterizes uterine leiomyomas but also may predict who will benefit from the embolization. MRI ability to detect coexistent uterine or pelvic pathology may change the diagnosis and treatment management of patients being evaluated for UAE.

  14. Vibration-proof FBR type reactor

    International Nuclear Information System (INIS)

    Kawamura, Yutaka.

    1992-01-01

    In a reactor container in an FBR type reactor, an outer building and upper and lower portions of a reactor container are connected by a load transmission device made of a laminated material of rubber and steel plates. Each of the reactor container and the outer building is disposed on a lower raft disposed on a rock by way of a vibration-proof device made of a laminated material of rubber and steel plates. Vibration-proof elements for providing vertical eigen frequency of the vibration-proof system comprising the reactor building and the vibration-proof device within a range of 3Hz to 5Hz are used. That is, the peak of designed acceleration for response spectrum in the horizontal direction of the reactor structural portions is shifted to side of shorter period from the main frequency region of the reactor structure. Alternatively, rigidity of the vibration-proof elements is decreased to shift the peak to the side of long period from the main frequency region. Designed seismic force can be greatly reduced both horizontally and vertically, to reduce the wall thickness of the structural members, improve the plant economy and to ensure the safety against earthquakes. (N.H.)

  15. Neonatal imaging using an on-site small footprint MR scanner

    Energy Technology Data Exchange (ETDEWEB)

    Merhar, Stephanie L. [Perinatal Institute, Division of Neonatology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Tkach, Jean A.; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Division of Pulmonary Medicine, Cincinnati, OH (United States); South, Andrew P.; Wiland, Emily L. [Children' s Hospital Medical Center of Akron, Division of Neonatology, Akron, OH (United States); Rattan, Mantosh S.; Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2017-07-15

    With its soft-tissue definition, multiplanar capabilities and advanced imaging techniques, magnetic resonance imaging (MRI) for neonatal care can provide better understanding of pathology, allowing for improved care and counseling to families. However, MR imaging in neonates is often difficult due to patient instability and the complex support necessary for survival. In our institution, we have installed a small footprint magnet in the neonatal intensive care unit (NICU) to minimize patient risks and provide the ability to perform MR imaging safely in this population. With this system, we have been able to provide more information with regard to central nervous system disorders, abdominal pathology, and pulmonary and airway abnormalities, and have performed postmortem imaging as an alternative or supplement to pathological autopsy. In our experience, an MR scanner situated within the NICU has allowed for safer and more expedited imaging of this vulnerable population. (orig.)

  16. Neonatal imaging using an on-site small footprint MR scanner

    International Nuclear Information System (INIS)

    Merhar, Stephanie L.; Tkach, Jean A.; Dumoulin, Charles L.; Woods, Jason C.; South, Andrew P.; Wiland, Emily L.; Rattan, Mantosh S.; Kline-Fath, Beth M.

    2017-01-01

    With its soft-tissue definition, multiplanar capabilities and advanced imaging techniques, magnetic resonance imaging (MRI) for neonatal care can provide better understanding of pathology, allowing for improved care and counseling to families. However, MR imaging in neonates is often difficult due to patient instability and the complex support necessary for survival. In our institution, we have installed a small footprint magnet in the neonatal intensive care unit (NICU) to minimize patient risks and provide the ability to perform MR imaging safely in this population. With this system, we have been able to provide more information with regard to central nervous system disorders, abdominal pathology, and pulmonary and airway abnormalities, and have performed postmortem imaging as an alternative or supplement to pathological autopsy. In our experience, an MR scanner situated within the NICU has allowed for safer and more expedited imaging of this vulnerable population. (orig.)

  17. Magnetic resonance imaging of the elbow. Part II: Abnormalities of the ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States)

    2005-01-01

    Part II of this comprehensive review on magnetic resonance imaging of the elbow discusses the role of magnetic resonance imaging in evaluating patients with abnormalities of the ligaments, tendons, and nerves of the elbow. Magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the soft tissue structures of the elbow. Magnetic resonance imaging can detect tears of the ulnar collateral ligament and lateral collateral ligament of the elbow with high sensitivity and specificity. Magnetic resonance imaging can determine the extent of tendon pathology in patients with medial epicondylitis and lateral epicondylitis. Magnetic resonance imaging can detect tears of the biceps tendon and triceps tendon and can distinguishing between partial and complete tendon rupture. Magnetic resonance imaging is also helpful in evaluating patients with nerve disorders at the elbow. (orig.)

  18. Proof of Concept for an Approach to a Finer Resolution Inventory

    Science.gov (United States)

    Chris J. Cieszewski; Kim Iles; Roger C. Lowe; Michal Zasada

    2005-01-01

    This report presents a proof of concept for a statistical framework to develop a timely, accurate, and unbiased fiber supply assessment in the State of Georgia, U.S.A. The proposed approach is based on using various data sources and modeling techniques to calibrate satellite image-based statewide stand lists, which provide initial estimates for a State inventory on a...

  19. Liver imaging with MDCT and high concentration contrast media

    International Nuclear Information System (INIS)

    Spielmann, Audrey L.

    2003-01-01

    Liver imaging has advanced greatly over the last 10 years with helical CT capability and more recently the addition of multidetector-row CT (MDCT). Multidetector CT technology facilitates imaging at faster speeds with improved image quality and less breathing artifact [Abdom. Imaging 25 (2000) 643]. Exquisite three-dimensional data sets can be obtained with thin collimation providing improved lesion detection, multiplanar imaging, and the ability to perform CT angiography of the liver and mesenteric vessels. New challenges arise with this advance in technology including safety considerations. The radiation dose to the patient has increased with MDCT and this is compounded by the ability to perform multi-phase liver imaging. Furthermore, issues of contrast media administration require reconsideration including optimal timing and rate of administration, the total volume of contrast needed and the ideal iodine concentration of the contrast media. Recently, the use of high concentration contrast media (HCCM) has been explored and study results to date will be reviewed

  20. 38 CFR 18b.64 - Offer of proof.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Offer of proof. 18b.64... Procedures § 18b.64 Offer of proof. An offer of proof made in connection with an objection taken to any... record as the offer of proof. ...

  1. Three-dimentional imaging of dentomaxillofacial region using electron beam tomography

    International Nuclear Information System (INIS)

    Tanaka, Takemasa; Kanda, Shigenobu; Muranaka, Toru

    1998-01-01

    Authors reported their results of the 3-D imaging of dentomaxillofacial region mainly for jaw deformity with electron beam tomography (EBT). The EBT apparatus used was Imatron C-100 (Imatron Corp.), with which, using bremsstrahlung radiation generated from the electron beam, CT is possible with rapid scanning rate at <0.1 sec. Imaging was done with those conditions as tube voltage: 130 kV, current: 610 mA, scanning rate: 0.1 sec/slice whose thickness was 1.5 mm, feeding rate: 1.5 mm and number of slices: 40-170. Patients were 15 cases with jaw deformity. Data were processed for 3-D image by Scribe Imaging Workstation (Multi-dimensional Imaging Inc.) which giving surface rendering and further by Power Macintosh 8500 (Apple Computer Inc.) with VoxBlast 1.1.0 (VayTec Inc.) software which giving volume rendering or with Image 1.60 (NIH) which allowing multi-planar reconstruction and re-analog projection. These actual images were presented in the report. (K.H.)

  2. Focused labeled proof systems for modal logic

    OpenAIRE

    Miller , Dale; Volpe , Marco

    2015-01-01

    International audience; Focused proofs are sequent calculus proofs that group inference rules into alternating positive and negative phases. These phases can then be used to define macro-level inference rules from Gentzen's original and tiny introduction and structural rules. We show here that the inference rules of labeled proof systems for modal logics can similarly be described as pairs of such phases within the LKF focused proof system for first-order classical logic. We consider the syst...

  3. Proust: A Nano Proof Assistant

    Directory of Open Access Journals (Sweden)

    Prabhakar Ragde

    2016-11-01

    Full Text Available Proust is a small Racket program offering rudimentary interactive assistance in the development of verified proofs for propositional and predicate logic. It is constructed in stages, some of which are done by students before using it to complete proof exercises, and in parallel with the study of its theoretical underpinnings, including elements of Martin-Lof type theory. The goal is twofold: to demystify some of the machinery behind full-featured proof assistants such as Coq and Agda, and to better integrate the study of formal logic with other core elements of an undergraduate computer science curriculum.

  4. Distributed analysis with PROOF in ATLAS collaboration

    International Nuclear Information System (INIS)

    Panitkin, S Y; Ernst, M; Ito, H; Maeno, T; Majewski, S; Rind, O; Tarrade, F; Wenaus, T; Ye, S; Benjamin, D; Montoya, G Carillo; Guan, W; Mellado, B; Xu, N; Cranmer, K; Shibata, A

    2010-01-01

    The Parallel ROOT Facility - PROOF is a distributed analysis system which allows to exploit inherent event level parallelism of high energy physics data. PROOF can be configured to work with centralized storage systems, but it is especially effective together with distributed local storage systems - like Xrootd, when data are distributed over computing nodes. It works efficiently on different types of hardware and scales well from a multi-core laptop to large computing farms. From that point of view it is well suited for both large central analysis facilities and Tier 3 type analysis farms. PROOF can be used in interactive or batch like regimes. The interactive regime allows the user to work with typically distributed data from the ROOT command prompt and get a real time feedback on analysis progress and intermediate results. We will discuss our experience with PROOF in the context of ATLAS Collaboration distributed analysis. In particular we will discuss PROOF performance in various analysis scenarios and in multi-user, multi-session environments. We will also describe PROOF integration with the ATLAS distributed data management system and prospects of running PROOF on geographically distributed analysis farms.

  5. Distributed analysis with PROOF in ATLAS collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Panitkin, S Y; Ernst, M; Ito, H; Maeno, T; Majewski, S; Rind, O; Tarrade, F; Wenaus, T; Ye, S [Brookhaven National Laboratory, Upton, NY 11973 (United States); Benjamin, D [Duke University, Durham, NC 27708 (United States); Montoya, G Carillo; Guan, W; Mellado, B; Xu, N [University of Wisconsin-Madison, Madison, WI 53706 (United States); Cranmer, K; Shibata, A [New York University, New York, NY 10003 (United States)

    2010-04-01

    The Parallel ROOT Facility - PROOF is a distributed analysis system which allows to exploit inherent event level parallelism of high energy physics data. PROOF can be configured to work with centralized storage systems, but it is especially effective together with distributed local storage systems - like Xrootd, when data are distributed over computing nodes. It works efficiently on different types of hardware and scales well from a multi-core laptop to large computing farms. From that point of view it is well suited for both large central analysis facilities and Tier 3 type analysis farms. PROOF can be used in interactive or batch like regimes. The interactive regime allows the user to work with typically distributed data from the ROOT command prompt and get a real time feedback on analysis progress and intermediate results. We will discuss our experience with PROOF in the context of ATLAS Collaboration distributed analysis. In particular we will discuss PROOF performance in various analysis scenarios and in multi-user, multi-session environments. We will also describe PROOF integration with the ATLAS distributed data management system and prospects of running PROOF on geographically distributed analysis farms.

  6. Complex proofs of real theorems

    CERN Document Server

    Lax, Peter D

    2011-01-01

    Complex Proofs of Real Theorems is an extended meditation on Hadamard's famous dictum, "The shortest and best way between two truths of the real domain often passes through the imaginary one." Directed at an audience acquainted with analysis at the first year graduate level, it aims at illustrating how complex variables can be used to provide quick and efficient proofs of a wide variety of important results in such areas of analysis as approximation theory, operator theory, harmonic analysis, and complex dynamics. Topics discussed include weighted approximation on the line, Müntz's theorem, Toeplitz operators, Beurling's theorem on the invariant spaces of the shift operator, prediction theory, the Riesz convexity theorem, the Paley-Wiener theorem, the Titchmarsh convolution theorem, the Gleason-Kahane-Żelazko theorem, and the Fatou-Julia-Baker theorem. The discussion begins with the world's shortest proof of the fundamental theorem of algebra and concludes with Newman's almost effortless proof of the prime ...

  7. From Inductive Reasoning to Proof

    Science.gov (United States)

    Yopp, David A.

    2009-01-01

    Mathematical proof is an expression of deductive reasoning (drawing conclusions from previous assertions). However, it is often inductive reasoning (conclusions drawn on the basis of examples) that helps learners form their deductive arguments, or proof. In addition, not all inductive arguments generate more formal arguments. This article draws a…

  8. MR imaging of the finger tendons: Normal anatomy and commonly encountered pathology

    International Nuclear Information System (INIS)

    Ragheb, Dina; Stanley, Anthony; Gentili, Amilcare; Hughes, Tudor; Chung, Christine B.

    2005-01-01

    MR imaging has emerged as a powerful tool in the evaluation of soft tissue structures such as the tendons of the hand and finger due to its excellent soft tissue contrast and multiplanar imaging capabilities. In the finger and hand, perhaps more than in any other location in the body, a detailed and intimate understanding of anatomy is crucial for lesion localization, directing clinical management and predicting long-term prognosis. These issues are of paramount importance to both the clinician and imager, both faced with the challenge of the complex anatomy and pathology associated with these delicate structures. The anatomy of the finger including intrinsic and extrinsic muscles, retinacular structures, and tendons will be discussed. The MR imaging features of common lesions of the tendons of the hand and finger will be reviewed

  9. Magnetic resonance imaging of epidermoid, including diffusion weighted images and an atypical case

    International Nuclear Information System (INIS)

    Takahashi, Shoki; Higano, Shuichi; Kurihara, Noriko

    1994-01-01

    In order to study the role of magnetic resonance imaging (MRI) in diagnosing intracranial epidermoid, we evaluated the MRI findings on five cases with such tumor, all of which were surgically verified. In addition to standard spin-echo (SE) images obtained in all cases, diffusion-weighted images were acquired in two patients. In four patients, the tumor revealed to be almost isointense relative to cerebrospinal fluid (CSF) on both T 1 -and T 2 -weighted images, while it tended to show slightly hyperintense to CSF on proton-density-weighted images; thus, based on the signal intensity on standard SE images the distinction between epidermoid and arachnoid cyst may be difficult. Furthermore, the presence of the tumor which has a tendency to grow in and along the subarachnoid space causing relatively minimal mass effect may be overlooked. Diffusion-weighted images were shown to have advantages in such cases by demonstrating the tumor unequivocally as a mass of high signal, and differentiating it from arachnoid cysts. In the remaining patient, its appearance was atypical, showing bright signal on both T 1 -and T 2 -weighted images. In conclusion free of bone artifacts, multiplanar MRI with additional diffusion-weighted images provides a clear demonstration of epidermoid, and its differentiation from arachnoid cyst, thus obviating the need for CT cisternography. (author)

  10. 2nd International Conference on Proof-Theoretic Semantics

    CERN Document Server

    Schroeder-Heister, Peter

    2016-01-01

    This volume is the first ever collection devoted to the field of proof-theoretic semantics. Contributions address topics including the systematics of introduction and elimination rules and proofs of normalization, the categorial characterization of deductions, the relation between Heyting's and Gentzen's approaches to meaning, knowability paradoxes, proof-theoretic foundations of set theory, Dummett's justification of logical laws, Kreisel's theory of constructions, paradoxical reasoning, and the defence of model theory. The field of proof-theoretic semantics has existed for almost 50 years, but the term itself was proposed by Schroeder-Heister in the 1980s. Proof-theoretic semantics explains the meaning of linguistic expressions in general and of logical constants in particular in terms of the notion of proof. This volume emerges from presentations at the Second International Conference on Proof-Theoretic Semantics in Tübingen in 2013, where contributing authors were asked to provide a self-contained descri...

  11. Proviola: a tool for proof re-animation

    NARCIS (Netherlands)

    Tankink, C.; Geuvers, J.H.; McKinna, J.; Wiedijk, F.; Autexier, S.; Calmet, J.; Delahaye, D.; Ion, P.D.F.; Rideau, L.; Rioboo, R.; Sexton, A.P.

    2010-01-01

    To improve on existing models of interaction with a proof assistant (PA), in particular for storage and replay of proofs, we introduce three related concepts, those of: a proof movie, consisting of frames which record both user input and the corresponding PA response; a camera, which films a user’s

  12. Short proofs of strong normalization

    OpenAIRE

    Wojdyga, Aleksander

    2008-01-01

    This paper presents simple, syntactic strong normalization proofs for the simply-typed lambda-calculus and the polymorphic lambda-calculus (system F) with the full set of logical connectives, and all the permutative reductions. The normalization proofs use translations of terms and types to systems, for which strong normalization property is known.

  13. Advances in medical imaging for the diagnosis and management of common genitourinary cancers.

    Science.gov (United States)

    Bagheri, Mohammad H; Ahlman, Mark A; Lindenberg, Liza; Turkbey, Baris; Lin, Jeffrey; Cahid Civelek, Ali; Malayeri, Ashkan A; Agarwal, Piyush K; Choyke, Peter L; Folio, Les R; Apolo, Andrea B

    2017-07-01

    Medical imaging of the 3 most common genitourinary (GU) cancers-prostate adenocarcinoma, renal cell carcinoma, and urothelial carcinoma of the bladder-has evolved significantly during the last decades. The most commonly used imaging modalities for the diagnosis, staging, and follow-up of GU cancers are computed tomography, magnetic resonance imaging (MRI), and positron emission tomography (PET). Multiplanar multidetector computed tomography and multiparametric MRI with diffusion-weighted imaging are the main imaging modalities for renal cell carcinoma and urothelial carcinoma, and although multiparametric MRI is rapidly becoming the main imaging tool in the evaluation of prostate adenocarcinoma, biopsy is still required for diagnosis. Functional and molecular imaging using 18-fluorodeoxyglucose-PET and sodium fluoride-PET are essential for the diagnosis, and especially follow-up, of metastatic GU tumors. This review provides an overview of the latest advances in the imaging of these 3 major GU cancers. Published by Elsevier Inc.

  14. 49 CFR 604.43 - Offer of proof.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Offer of proof. 604.43 Section 604.43..., DEPARTMENT OF TRANSPORTATION CHARTER SERVICE Hearings. § 604.43 Offer of proof. A party whose evidence has... respond to the offer of proof, may offer the evidence on the record when filing an appeal. ...

  15. 36 CFR 1150.79 - Offer of proof.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Offer of proof. 1150.79... BOARD PRACTICE AND PROCEDURES FOR COMPLIANCE HEARINGS Hearing Procedures § 1150.79 Offer of proof. An offer of proof made in connection with an objection taken to a ruling of the judge rejecting or...

  16. Integrating PROOF Analysis in Cloud and Batch Clusters

    International Nuclear Information System (INIS)

    Rodríguez-Marrero, Ana Y; Fernández-del-Castillo, Enol; López García, Álvaro; Marco de Lucas, Jesús; Matorras Weinig, Francisco; González Caballero, Isidro; Cuesta Noriega, Alberto

    2012-01-01

    High Energy Physics (HEP) analysis are becoming more complex and demanding due to the large amount of data collected by the current experiments. The Parallel ROOT Facility (PROOF) provides researchers with an interactive tool to speed up the analysis of huge volumes of data by exploiting parallel processing on both multicore machines and computing clusters. The typical PROOF deployment scenario is a permanent set of cores configured to run the PROOF daemons. However, this approach is incapable of adapting to the dynamic nature of interactive usage. Several initiatives seek to improve the use of computing resources by integrating PROOF with a batch system, such as Proof on Demand (PoD) or PROOF Cluster. These solutions are currently in production at Universidad de Oviedo and IFCA and are positively evaluated by users. Although they are able to adapt to the computing needs of users, they must comply with the specific configuration, OS and software installed at the batch nodes. Furthermore, they share the machines with other workloads, which may cause disruptions in the interactive service for users. These limitations make PROOF a typical use-case for cloud computing. In this work we take profit from Cloud Infrastructure at IFCA in order to provide a dynamic PROOF environment where users can control the software configuration of the machines. The Proof Analysis Framework (PAF) facilitates the development of new analysis and offers a transparent access to PROOF resources. Several performance measurements are presented for the different scenarios (PoD, SGE and Cloud), showing a speed improvement closely correlated with the number of cores used.

  17. 34 CFR 101.85 - Offer of proof.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Offer of proof. 101.85 Section 101.85 Education... PRACTICE AND PROCEDURE FOR HEARINGS UNDER PART 100 OF THIS TITLE Hearing Procedures § 101.85 Offer of proof. An offer of proof made in connection with an objection taken to any ruling of the presiding officer...

  18. 7 CFR 15.122 - Offer of proof.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Offer of proof. 15.122 Section 15.122 Agriculture..., Decisions and Administrative Review Under the Civil Rights Act of 1964 Hearing Procedures § 15.122 Offer of proof. An offer of proof made in connection with an objection taken to any ruling of the hearing officer...

  19. 43 CFR 4.840 - Offer of proof.

    Science.gov (United States)

    2010-10-01

    ... the Interior-Effectuation of Title VI of the Civil Rights Act of 1964 Hearing § 4.840 Offer of proof. An offer of proof made in connection with an objection taken to any ruling of the administrative law... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Offer of proof. 4.840 Section 4.840 Public...

  20. An Architecture for Proof Planning Systems

    OpenAIRE

    Dennis, Louise Abigail

    2005-01-01

    This paper presents a generic architecture for proof planning systems in terms of an interaction between a customisable proof module and search module. These refer to both global and local information contained in reasoning states.

  1. The Proof is in the Pudding The Changing Nature of Mathematical Proof

    CERN Document Server

    Krantz, Steven G

    2011-01-01

    This text explores the many transformations that the mathematical proof has undergone from its inception to its versatile, present-day use, considering the advent of high-speed computing machines. Though there are many truths to be discovered in this book, by the end it is clear that there is no formalized approach or standard method of discovery to date. Most of the proofs are discussed in detail with figures and equations accompanying them, allowing both the professional mathematician and those less familiar with mathematics to derive the same joy from reading this book.

  2. CT imaging of bronchus related to solitary pulmonary lesion: comparison of minimum intensity projection and multi-planar reconstruction

    International Nuclear Information System (INIS)

    Zhou Jun; Shan Fei; Zhang Zhiyong; Yang Shan; Zhang Xingwei; Wu Dong; Zhan Songhua

    2011-01-01

    Objective: To investigate the clinical value of 64-slice computed tomography with MinIP and MPR for imaging the bronchus related to a solitary pulmonary lesion (SPL). Methods: Seventy-five subjects with solitary pulmonary lesions underwent chest 64-slice CT and their bronchi were analyzed retrospectively. All images of thin-section (0.625 mm) were reconstructed with MPR and MinIP into images of 1, 2, 3, and 5 mm thickness and 1 mm gap in two orthogonal planes along the long axis of bronchus related to the SPL. The image quality of four series of MinIP and MPR images was evaluated in the aspect of bronchus visibility and pulmonary vascular masking. One-way ANOVA with Bonferroni correction and interclass correlation coefficient were used in the statistical analysis. Results: (1) The mean scores of display of the bronchi on MinIP images of four series (4.85, 4.77 and 4.84, 4.63 and 4.67, 4.25 and 4.28, in 1, 2, 3, and 5 mm thickness, respectively) and on MPR images of 1 or 2 mm thickness (4.77 and 4.76, 4.04 and 4.27, in 1 and 2 mm thickness, respectively) were good or excellent. MPR images of 1 mm thickness and MinIP images of 1-3 mm thickness showed no significant differences (t=0.318, P> 0.05 for all), but they were superior to MinIP images of 5 mm thickness (t=6.318 and 6.610, P 0.05). (2) The effect of suppression of pulmonary vascular markings on MinIP images was better with the increase of slice thickness (F= 45.312 and 40.415, P<0.01). The mean scores of MinIP images of 3 mm and 5 mm thickness (4.67 and 4.64, 5.00 and 4.97, for 3 and 5 mm thickness, respectively) were good or excellent, but MinIP images of 2 mm thickness were just acceptable. Conclusion: MinIP images of 3 mm thickness may display the bronchus related to SPL more clearly. (authors)

  3. Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences

    International Nuclear Information System (INIS)

    Kim, Seong Hyun; Choi, Dongil; Lim, Hyo K.; Kim, Min Ju; Jang, Kyung Mi; Kim, Seung Hoon; Lee, Won Jae; Lee, Jongmee; Jeon, Yong Hwan; Lim, Jae Hoon

    2006-01-01

    Objective: To compare the diagnostic performance of a variety of magnetic resonance imaging (MRI) sequences, in order to identify the most effective ferucarbotran-enhanced sequence for the detection of multiple small hepatic VX2 carcinomas in rabbits. Methods: Fifteen rabbits with experimentally induced 135 VX2 carcinomas in the liver underwent ferucarbotran-enhanced MRI using the following nine pulse sequences: a fat-suppressed fast spin-echo (FSE) sequence with two echo times (TE) (proton density- and T2-weighted images), four different T2*-weighted fast multiplanar GRASS (gradient-recalled acquisition in the steady state) (FMPGR) with the combination of three TEs (9, 12, 15 ms, respectively) and two flip angles (20 deg., 80 deg., respectively), T2*-weighted fast multiplanar spoiled GRASS (FMPSPGR), T1-weighted FMPSPGR, and dynamic T1-weighted FMPSPGR. All images were reviewed by three radiologists with quantitative and qualitative analysis. Results: Tumor-to-liver contrast-to-noise ratio of the proton density-weighted FSE sequence was significantly higher than those of the others (p o ) images were superior to those of the others and for the detection of very small hepatic tumors of less than 5 mm, the sensitivities of these sequences were less than 30%. Conclusion: Ferucarbotran-enhanced T2- and proton density-weighted FSE and T2*-weighed FMPGR (TE/flip angle, 12/20 o ) images were found to be the most effective pulse sequences for the detection of multiple small hepatic VX2 carcinomas but these sequences were limited in the detection of very small hepatic tumors of less than 5 mm in size

  4. Extra-adrenal pheochromocytoma in pregnancy: ultrasonography and magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Carson, B.J.W.; Johnston, M.A.; Iwaniuk, G.

    1995-04-01

    The case of a 24-year-old woman with extra-adrenal pheochromocytoma during pregnancy was described. Initial ultrasonography (US) at 27 weeks gestational age failed to show the pheochromocytoma, which was subsequently found by US at 35 weeks gestational age. Magnetic resonance imaging (MRI) provided diagnostic confirmation, as well as important information used by the obstetrician and the surgeon in operative planning. MRI proved to be ideally suited to investigation of extra-adrenal pheochromocytomas in pregnancy because it does not use ionizing radiation, and it has multiplanar capability and high contrast resolution. In the case described, the lesion was demonstrated with all MRI pulse sequences, but was best visualized with turbo spin-echo T2-weighted imaging, as well as with fat-suppressed imaging. 7 refs., 2 figs.

  5. Parallel interactive data analysis with PROOF

    International Nuclear Information System (INIS)

    Ballintijn, Maarten; Biskup, Marek; Brun, Rene; Canal, Philippe; Feichtinger, Derek; Ganis, Gerardo; Kickinger, Guenter; Peters, Andreas; Rademakers, Fons

    2006-01-01

    The Parallel ROOT Facility, PROOF, enables the analysis of much larger data sets on a shorter time scale. It exploits the inherent parallelism in data of uncorrelated events via a multi-tier architecture that optimizes I/O and CPU utilization in heterogeneous clusters with distributed storage. The system provides transparent and interactive access to gigabytes today. Being part of the ROOT framework PROOF inherits the benefits of a performant object storage system and a wealth of statistical and visualization tools. This paper describes the data analysis model of ROOT and the latest developments on closer integration of PROOF into that model and the ROOT user environment, e.g. support for PROOF-based browsing of trees stored remotely, and the popular TTree::Draw() interface. We also outline the ongoing developments aimed to improve the flexibility and user-friendliness of the system

  6. An Automated, Image Processing System for Concrete Evaluation

    International Nuclear Information System (INIS)

    Baumgart, C.W.; Cave, S.P.; Linder, K.E.

    1998-01-01

    Allied Signal Federal Manufacturing ampersand Technologies (FM ampersand T) was asked to perform a proof-of-concept study for the Missouri Highway and Transportation Department (MHTD), Research Division, in June 1997. The goal of this proof-of-concept study was to ascertain if automated scanning and imaging techniques might be applied effectively to the problem of concrete evaluation. In the current evaluation process, a concrete sample core is manually scanned under a microscope. Voids (or air spaces) within the concrete are then detected visually by a human operator by incrementing the sample under the cross-hairs of a microscope and by counting the number of ''pixels'' which fall within a void. Automation of the scanning and image analysis processes is desired to improve the speed of the scanning process, to improve evaluation consistency, and to reduce operator fatigue. An initial, proof-of-concept image analysis approach was successfully developed and demonstrated using acquired black and white imagery of concrete samples. In this paper, the automated scanning and image capture system currently under development will be described and the image processing approach developed for the proof-of-concept study will be demonstrated. A development update and plans for future enhancements are also presented

  7. Why prove it again? alternative proofs in mathematical practice

    CERN Document Server

    Dawson, Jr , John W

    2015-01-01

    This monograph considers several well-known mathematical theorems and asks the question, “Why prove it again?” while examining alternative proofs.   It  explores the different rationales mathematicians may have for pursuing and presenting new proofs of previously established results, as well as how they judge whether two proofs of a given result are different.  While a number of books have examined alternative proofs of individual theorems, this is the first that presents comparative case studies of other methods for a variety of different theorems. The author begins by laying out the criteria for distinguishing among proofs and enumerates reasons why new proofs have, for so long, played a prominent role in mathematical practice.  He then outlines various purposes that alternative proofs may serve.  Each chapter that follows provides a detailed case study of alternative proofs for particular theorems, including the Pythagorean Theorem, the Fundamental Theorem of Arithmetic, Desargues’ Theorem, the...

  8. Two proofs of Fine's theorem

    International Nuclear Information System (INIS)

    Halliwell, J.J.

    2014-01-01

    Fine's theorem concerns the question of determining the conditions under which a certain set of probabilities for pairs of four bivalent quantities may be taken to be the marginals of an underlying probability distribution. The eight CHSH inequalities are well-known to be necessary conditions, but Fine's theorem is the striking result that they are also sufficient conditions. Here two transparent and self-contained proofs of Fine's theorem are presented. The first is a physically motivated proof using an explicit local hidden variables model. The second is an algebraic proof which uses a representation of the probabilities in terms of correlation functions. - Highlights: • A discussion of the various approaches to proving Fine's theorem. • A new physically-motivated proof using a local hidden variables model. • A new algebraic proof. • A new form of the CHSH inequalities

  9. Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Choi, Dongil; Lim, Jae Hoon; Lee, Won Jae; Jang, Hyun Jung; Lim, Kyo Keun; Lee, Soon Jin; Cho, Jae Min; Kim, Seung Kwon; Kim, Gab Chul

    2002-01-01

    To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of 15 μmol/Kg was slowly infused intravenously, and axial images of seven sequences were obtained 30 minutes after the end of infusion. The MR protocol included fast spin-echo (FSE) with two echo times (TR3333-8571/TE18 and 90-117), singleshot FSE (SSFSE) with two echo times (TR∞/TE39 and 98), T2-weighted gradient-recalled acquisition in the steady state (GRASS) (TR216/TE20), T2-weighted fast multiplanar GRASS (FMPGR) (TR130/TE8.4-9.5), and T2-weighted fast multiplanar spoiled GRASS (FMPSPGR) (TR130/TE8.4-9.5). Contrast-to-noise ratios (CNRs) of HCCs determined during the imaging sequences formed the basis of quantitative analysis, and images were qualitatively assessed in terms of lesion conspicuity and image artifacts. The diagnostic accuracy of all sequences was assessed using receiver operating characteristic (ROC) analysis. Quantitative analysis revealed that the CNRs of T2-weighted FMPGR and T2-weighted FMPSPGR were significantly higher than those of the other sequences, while qualitative analysis showed that image artifacts were prominent at T2-weighted GRASS imaging. Lesion conspicuity was statistically significantly less clear at SSFSE imaging. In term of lesion detection, T-weighted FMPGR, T2- weighted FMPSPGR, and proton density FSE imaging were statistically superior to the others. T2-weighted FMPGR, T2- weighted FMPSPGR, and proton density FSE appear to be the optimal pulse sequences for ferumoxidesenhanced MR imaging in the detection of HCCs

  10. Evaluation of the anterior ethmoidal artery by 3D dual volume rotational digital subtraction angiography and native multidetector CT with multiplanar reformations. Initial findings.

    Science.gov (United States)

    Pandolfo, Ignazio; Vinci, Sergio; Salamone, Ignazio; Granata, Francesca; Mazziotti, Silvio

    2007-06-01

    Our purpose is to codify the anterior ethmoidal artery (AEA) course and its relationship with adjacent structures. Twenty patients with cerebrovascular disease underwent selective internal carotid dual volume angiography. Fusion of the vascular and bony images was obtained successively on a second console. MDCT of the cranium was performed in all patients. To identify the AEA course, multiplanar CT reformations were obtained. In all cases the entry-point of AEA and its course were identified by means of dual volume angiography. The information was confirmed by MDCT. In a second phase, we studied another 78 patients affected by inflammatory disease and polyposis only by means of MDCT, in order to confirm the previous data obtained by comparison between angiography and MDCT. In this second phase, 110/156 vessels were indirectly detected by means of visualization of the ethmoidal entry point. In the remaining cases, AEA was directly shown due to integrity of the thin ethmoidal bone lamellae or bony canal. Dual volume angiography is essential to identify the course of the AEA (standard of reference for the interpretation of CT). In patients with benign rhinosinusal pathology, where invasivity techniques are not justified, MPR reconstructions were of pivotal importance in the evaluation of the course of the artery with particular reference to its relationship with the frontal recess.

  11. The statistical strength of nonlocality proofs

    NARCIS (Netherlands)

    Dam, van W.; Gill, R.D.; Grünwald, P.D.

    2005-01-01

    There exist numerous proofs of Bell's theorem, stating that quantum mechanics is incompatible with local realistic theories of nature. Here the strength of such nonlocality proofs is defined in terms of the amount of evidence against local realism provided by the corresponding experiments.

  12. Imaging system for creating 3D block-face cryo-images of whole mice

    Science.gov (United States)

    Roy, Debashish; Breen, Michael; Salvado, Olivier; Heinzel, Meredith; McKinley, Eliot; Wilson, David

    2006-03-01

    We developed a cryomicrotome/imaging system that provides high resolution, high sensitivity block-face images of whole mice or excised organs, and applied it to a variety of biological applications. With this cryo-imaging system, we sectioned cryo-preserved tissues at 2-40 μm thickness and acquired high resolution brightfield and fluorescence images with microscopic in-plane resolution (as good as 1.2 μm). Brightfield images of normal and pathological anatomy show exquisite detail, especially in the abdominal cavity. Multi-planar reformatting and 3D renderings allow one to interrogate 3D structures. In this report, we present brightfield images of mouse anatomy, as well as 3D renderings of organs. For BPK mice model of polycystic kidney disease, we compared brightfield cryo-images and kidney volumes to MRI. The color images provided greater contrast and resolution of cysts as compared to in vivo MRI. We note that color cryo-images are closer to what a researcher sees in dissection, making it easier for them to interpret image data. The combination of field of view, depth of field, ultra high resolution and color/fluorescence contrast enables cryo-image volumes to provide details that cannot be found through in vivo imaging or other ex vivo optical imaging approaches. We believe that this novel imaging system will have applications that include identification of mouse phenotypes, characterization of diseases like blood vessel disease, kidney disease, and cancer, assessment of drug and gene therapy delivery and efficacy and validation of other imaging modalities.

  13. Multiparty session types as coherence proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2017-01-01

    We propose a Curry–Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof nor...

  14. Proof Mining in L1-Approximation

    DEFF Research Database (Denmark)

    Oliva, Paulo Borges; Kohlenbach, Ulrich

    2001-01-01

    In this paper, we present another case study in the general project of proof mining which means the logical analysis of prima facie non-effective proofs with the aim of extracting new computationally relevant data. We use techniques based on monotone functional interpretation developed...

  15. Velocity feedback control with a flywheel proof mass actuator

    Science.gov (United States)

    Kras, Aleksander; Gardonio, Paolo

    2017-08-01

    This paper presents four new proof mass actuators to be used in velocity feedback control systems for the control of vibrations of machines and flexible structures. A classical proof mass actuator is formed by a coil-magnet linear motor, with either the magnet or the armature-coil proof mass suspended on soft springs. This arrangement produces a net force effect at frequencies above the fundamental resonance frequency of the springs-proof mass system. Thus, it can be used to implement point velocity feedback loops, although the dynamic response and static deflection of the springs-proof mass system poses some stability and control performance limitations. The four proof mass actuators presented in this study include a flywheel element, which is used to augment the inertia effect of the suspended proof mass. The paper shows that the flywheel element modifies both the dynamic response and static deflection of the springs-proof mass system in such a way as the stability and control performance of velocity feedback loops using these actuators are significantly improved.

  16. Hybrid Logic and its Proof-Theory

    CERN Document Server

    Brauner, Torben

    2011-01-01

    This is the first book-length treatment of hybrid logic and its proof-theory. Hybrid logic is an extension of ordinary modal logic which allows explicit reference to individual points in a model (where the points represent times, possible worlds, states in a computer, or something else). This is useful for many applications, for example when reasoning about time one often wants to formulate a series of statements about what happens at specific times. There is little consensus about proof-theory for ordinary modal logic. Many modal-logical proof systems lack important properties and the relatio

  17. 16 CFR 614.1 - Appropriate proof of identity.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Appropriate proof of identity. 614.1 Section... IDENTITY § 614.1 Appropriate proof of identity. (a) Consumer reporting agencies shall develop and implement reasonable requirements for what information consumers shall provide to constitute proof of identity for...

  18. Proof Mining in L1-Approximation

    DEFF Research Database (Denmark)

    Kohlenbach, Ulrich; Oliva, Paulo Borges

    2003-01-01

    n this paper, we present another case study in the general project of proof mining which means the logical analysis of prima facie non-effective proofs with the aim of extracting new computationally relevant data. We use techniques based on monotone functional interpretation developed in Kohlenbach...

  19. Evaluating Google compute engine with PROOF

    International Nuclear Information System (INIS)

    Ganis, Gerardo; Panitkin, Sergey

    2014-01-01

    The advent of private and commercial cloud platforms has opened the question of evaluating the cost-effectiveness of such solution for computing in High Energy Physics . Google Compute Engine (GCE) is a IaaS product launched by Google as an experimental platform during 2012 and now open to the public market. In this contribution we present the results of a set of CPU-intensive and I/O-intensive tests we have run with PROOF on a GCE resources made available by Google for test purposes. We have run tests on large scale PROOF clusters (up to 1000 workers) to study the overall scalability of coordinated multi-process jobs. We have studied and compared the performance of ephemeral and persistent storage with PROOF-Lite on the single machines and of standard PROOF on the whole cluster. We will discuss our results in perspective, in particular with respect to the typical analysis needs of an LHC experiment.

  20. 29 CFR 1919.31 - Proof tests-loose gear.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Proof tests-loose gear. 1919.31 Section 1919.31 Labor... (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof Loads; Heat Treatment; Competent Persons § 1919.31 Proof tests—loose gear. (a) Chains, rings, shackles and other loose gear (whether...

  1. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.S. [Ohio State Univ., Columbus (United States). Dept. of Radiology

    2000-09-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  2. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    International Nuclear Information System (INIS)

    Yu, J.S.

    2000-01-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  3. Other trigonometric proofs of Pythagoras theorem

    OpenAIRE

    Luzia, Nuno

    2015-01-01

    Only very recently a trigonometric proof of the Pythagoras theorem was given by Zimba \\cite{1}, many authors thought this was not possible. In this note we give other trigonometric proofs of Pythagoras theorem by establishing, geometrically, the half-angle formula $\\cos\\theta=1-2\\sin^2 \\frac{\\theta}{2}$.

  4. Burdens of Proof, Presumptions and Standards of Proof in Criminal ...

    African Journals Online (AJOL)

    Worku_Y

    evidential and persuasive burdens of proof as between the state and the ..... scholars have observed that the evidential burden is a function of the burden of ..... required to convince judges by creating such an intensity of belief in their minds.

  5. Determining paediatric patient thickness from a single digital radiograph-a proof of principle.

    Science.gov (United States)

    Worrall, Mark; Vinnicombe, Sarah; Sutton, David G

    2018-04-05

    This work presents a proof of principle for a method of estimating the thickness of an attenuator from a single radiograph using the image, the exposure factors with which it was acquired and a priori knowledge of the characteristics of the X-ray unit and detector used for the exposure. It is intended this could be developed into a clinical tool to assist with paediatric patient dose audit, for which a measurement of patient size is required. The proof of principle used measured pixel value and effective linear attenuation coefficient to estimate the thickness of a Solid Water attenuator. The kerma at the detector was estimated using a measurement of pixel value on the image and measured detector calibrations. The initial kerma was estimated using a lookup table of measured output values. The effective linear attenuation coefficient was measured for Solid Water at varying kV p . 11 test images of known and varying thicknesses of Solid Water were acquired at 60, 70 and 81 kV p . Estimates of attenuator thickness were made using the model and the results compared to the known thickness. Estimates of attenuator thickness made using the model differed from the known thickness by 3.8 mm (3.2%) on average, with a range of 0.5-10.8 mm (0.5-9%). A proof of principle is presented for a method of estimating the thickness of an attenuator using a single radiograph of the attenuator. The method has been shown to be accurate using a Solid Water attenuator, with a maximum difference between estimated and known attenuator thickness of 10.8 mm (9%). The method shows promise as a clinical tool for estimating abdominal paediatric patient thickness for paediatric patient dose audit, and is only contingent on the type of data routinely collected by Medical Physics departments. Advances in knowledge: A computational model has been created that is capable of accurately estimating the thickness of a uniform attenuator using only the radiographic image, the exposure factors with which

  6. Generalization of the Greenberger-Horne-Zeilinger algebraic proof of nonlocality

    International Nuclear Information System (INIS)

    Clifton, R.K.; Redhead, M.L.G.; Butterfield, J.N.

    1991-01-01

    The authors further develop a recent new proof (by Greenberger, Horne, and Zeilinger - GHZ) that local deterministic hidden-variable theories are inconsistent with certain strict correlations predicted by quantum mechanics. First, they generalize GHZ's proof so that it applied to factorable stochastic theories in which apparatus hidden variables are casually relevant to measurement results, and theories in which the hidden variables evolve indeterministically prior to the particle-apparatus interactions. Then they adopt a more general measure-theoretic approach which requires that GHZ's argument be modified in order to produce a valid proof. Finally, they motivate the more general proof's assumptions in a somewhat different way from previous authors in order to strengthen the implications of the proof as much as possible. After developing GHZ's proof along these lines, they then consider the analogue, for their proof, of Bohr's reply to the EPR argument, and conclude (pace GHZ) that in at least one respect (viz, that of most concern to Bohr) the proof is no more powerful than Bell's. Nevertheless, they point out some new advantages of their proof over Bell's, and over other algebraic proofs of nonlocality. And they conclude by giving a modified version of their proof that, like Bell's does not rely on experimentally unrealizable strict correlations, but still leads to a testable quasi-algebraic locality inequality

  7. Proof Mapping

    Science.gov (United States)

    Linares, Leanne A.; Smith, Phil R.

    2009-01-01

    A geometry textbook or mathematics journal that prints all the work that mathematicians use as they generate proofs of mathematical results would be rare indeed. The false starts, the tentative conjectures, and the arguments that led nowhere--these are conveniently omitted; only the final successful product is presented to the world. To students…

  8. On Kripke-style semantics for the provability logic of Gödel’s proof predicate with quantifiers on proofs

    NARCIS (Netherlands)

    Yavorskiy, R.

    Kripke-style semantics is suggested for the provability logic with quantifiers on proofs corresponding to the standard Gödel proof predicate. It is proved that the set of valid formulas is decidable. The arithmetical completeness is still an open issue.

  9. Y-90 SPECT ML image reconstruction with a new model for tissue-dependent bremsstrahlung production using CT information: a proof-of-concept study

    Science.gov (United States)

    Lim, Hongki; Fessler, Jeffrey A.; Wilderman, Scott J.; Brooks, Allen F.; Dewaraja, Yuni K.

    2018-06-01

    While the yield of positrons used in Y-90 PET is independent of tissue media, Y-90 SPECT imaging is complicated by the tissue dependence of bremsstrahlung photon generation. The probability of bremsstrahlung production is proportional to the square of the atomic number of the medium. Hence, the same amount of activity in different tissue regions of the body will produce different numbers of bremsstrahlung photons. Existing reconstruction methods disregard this tissue-dependency, potentially impacting both qualitative and quantitative imaging of heterogeneous regions of the body such as bone with marrow cavities. In this proof-of-concept study, we propose a new maximum-likelihood method that incorporates bremsstrahlung generation probabilities into the system matrix, enabling images of the desired Y-90 distribution to be reconstructed instead of the ‘bremsstrahlung distribution’ that is obtained with existing methods. The tissue-dependent probabilities are generated by Monte Carlo simulation while bone volume fractions for each SPECT voxel are obtained from co-registered CT. First, we demonstrate the tissue dependency in a SPECT/CT imaging experiment with Y-90 in bone equivalent solution and water. Visually, the proposed reconstruction approach better matched the true image and the Y-90 PET image than the standard bremsstrahlung reconstruction approach. An XCAT phantom simulation including bone and marrow regions also demonstrated better agreement with the true image using the proposed reconstruction method. Quantitatively, compared with the standard reconstruction, the new method improved estimation of the liquid bone:water activity concentration ratio by 40% in the SPECT measurement and the cortical bone:marrow activity concentration ratio by 58% in the XCAT simulation.

  10. Towards an Intelligent Tutor for Mathematical Proofs

    Directory of Open Access Journals (Sweden)

    Serge Autexier

    2012-02-01

    Full Text Available Computer-supported learning is an increasingly important form of study since it allows for independent learning and individualized instruction. In this paper, we discuss a novel approach to developing an intelligent tutoring system for teaching textbook-style mathematical proofs. We characterize the particularities of the domain and discuss common ITS design models. Our approach is motivated by phenomena found in a corpus of tutorial dialogs that were collected in a Wizard-of-Oz experiment. We show how an intelligent tutor for textbook-style mathematical proofs can be built on top of an adapted assertion-level proof assistant by reusing representations and proof search strategies originally developed for automated and interactive theorem proving. The resulting prototype was successfully evaluated on a corpus of tutorial dialogs and yields good results.

  11. Applicability of the 3D-VIBE sequence to whole brain imaging

    International Nuclear Information System (INIS)

    Makabe, Takeshi; Nakamura, Manami; Moriyama, Ryo

    2009-01-01

    The volumetric interpolated breath-hold examination (VIBE) method has been developed imaging also holds its breath in an abdomen, and to do three-dimensional T1WI in possible time in gradient echo sequence, and applied to dynamic study mainly and planning for time reduction using an interpolation and partial fourier. We considered the condition for imaging to do whole brain as high resolution image using VIBE. Even if base matrix was maintained when an interpolation and partial fourier were used too much excessively by Phantom experiment, the resolution of multiplanar reconstruction (MPR) image fell. There was a limit of the interpolation therefore to maintain the resolution as voxel. Signal-to-noise ratio (SNR) fell by flip angle (FA) increase by the applicability to the head, and peak existed in about 15 deg in contrast-to-noise ratio (CNR) of white matter and gray matter. Therefore by it's clinical and optimizing the imaging condition of VIBE, whole brain, it was imaging possible in about 3 minutes as high resolution image. (author)

  12. MR imaging of the toracic aorta

    International Nuclear Information System (INIS)

    Garbagnati, F.; Castoldi, M.C.; Bianchini, E.

    1988-01-01

    Various pathological conditions of the thoracic aorta were studied by MR Imaging in 31 patients: 23 were aneurysms (branching and non-branching), 2 artero-venous fistulae, 2 aortic prostheses, 2 Marfan's syndromes, 1 coronary sinus aneurysm, and 1 isthmic stenosis. MRI studies were always performed on patients who had been examined by other imaging procedures. A comparative study was carried out on the results of MRI, angiography, computerized tomography, and ultrasounds. The possibility of propedeutic protocol was explored. Our experience, in accordance with the literature on the subject, indicates MRI as the procedure of choice in the study of aneurysms of the toracic aorta. The advantages offered by MRI-the high natural contrast between circulating blood and the supporting structures, the possibility of obtaining multiplanar images as well as data on intraluminal, parietal, and extraparietal conditions-make it a highly competitive procedure if compared to either CT or angiography. While awaiting further evidence, the use of a propedeutic protocol in non-aneurysmatic diseases is still not advisable, due to insufficient patient population, and to the lack of a consistent literature on the subject

  13. Proof test diagrams for Zerodur glass-ceramic

    Science.gov (United States)

    Tucker, D. S.

    1991-01-01

    Proof test diagrams for Zerodur glass-ceramics are calculated from available fracture mechanics data. It is shown that the environment has a large effect on minimum time-to-failure as predicted by proof test diagrams.

  14. Implicit proofs

    Czech Academy of Sciences Publication Activity Database

    Krajíček, Jan

    2004-01-01

    Roč. 69, č. 2 (2004), s. 387-397 ISSN 0022-4812 R&D Projects: GA AV ČR IAA1019901; GA MŠk LN00A056 Institutional research plan: CEZ:AV0Z1019905 Keywords : propositional proof system s * circuits * polynomial simulation Subject RIV: BA - General Mathematics Impact factor: 0.331, year: 2004

  15. Recent advances in imaging technologies in implant dentistry

    Directory of Open Access Journals (Sweden)

    Sharad Sahai

    2015-01-01

    Full Text Available Dental implants have become a part of routine treatment plans in oral rehabilitation. Diagnostic imaging is critical to presurgical treatment planning and the success of implants. Various imaging modalities may aid the placing of implants in an appropriate location with relative ease and also obtain a predictable outcome. Cross-sectional imaging techniques such as computed tomography (CT and, more recently, cone beam-computed tomography (CBCT are invaluable during preoperative planning for endosseous dental implantation procedures. An understanding of geometric and software parameters, and image formatting options to maximize image display is necessary to optimize diagnostic yield while maintaining minimal patient radiation dose. Multiplanar CT or CBCT images contain far more detailed information of the maxillofacial region than do panoramic or other bidimensional (2D images and necessitate a thorough knowledge of the tridimensional (3D anatomy of the region and considerations of variability in the range of the anatomically normal. This article provides: (1 an overview of the fundamental principles of operation of maxillofacial CT and CBCT; (2 an understanding of image processing and display protocols specific to pre-implant bone assessment; (3 the basics of qualitative and quantitative bone evaluation; and (4 an introduction to image-guided implant surgery using custom or computer-generated surgical guides.

  16. CT and MR imaging of the normal and pathologic conditions of the facial nerve

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, Lorenz E-mail: jaeger@ikra.med.uni-muenchen.de; Reiser, Maximilian

    2001-11-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are well established imaging modalities to examine the facial nerve as well as the course of the facial nerve itself. High spatial resolution is guaranteed not only in the x- and y-axis, but also in the z-axis using multislice spiral CT. With this technique, reformatted multiplanar images in oblique planes, avoiding additional examinations in the coronal plane, facilitate the delineation of the facial nerve canal. This is beneficial in patients with temporal bone trauma, malformation or osseous changes. MR has a superior soft-tissue contrast to CT that enables imaging of the facial nerve itself. Therefore the normal facial nerve as well as pathologic changes of the facial nerve is readily visualized from the brain stem to the parotid gland. This review article presents anatomy, pathology and imaging strategies in the diagnostics of the facial nerve.

  17. Reconstruction of 3D Shapes of Opaque Cumulus Clouds from Airborne Multiangle Imaging: A Proof-of-Concept

    Science.gov (United States)

    Davis, A. B.; Bal, G.; Chen, J.

    2015-12-01

    Operational remote sensing of microphysical and optical cloud properties is invariably predicated on the assumption of plane-parallel slab geometry for the targeted cloud. The sole benefit of this often-questionable assumption about the cloud is that it leads to one-dimensional (1D) radiative transfer (RT)---a textbook, computationally tractable model. We present new results as evidence that, thanks to converging advances in 3D RT, inverse problem theory, algorithm implementation, and computer hardware, we are at the dawn of a new era in cloud remote sensing where we can finally go beyond the plane-parallel paradigm. Granted, the plane-parallel/1D RT assumption is reasonable for spatially extended stratiform cloud layers, as well as the smoothly distributed background aerosol layers. However, these 1D RT-friendly scenarios exclude cases that are critically important for climate physics. 1D RT---whence operational cloud remote sensing---fails catastrophically for cumuliform clouds that have fully 3D outer shapes and internal structures driven by shallow or deep convection. For these situations, the first order of business in a robust characterization by remote sensing is to abandon the slab geometry framework and determine the 3D geometry of the cloud, as a first step toward bone fide 3D cloud tomography. With this specific goal in mind, we deliver a proof-of-concept for an entirely new kind of remote sensing applicable to 3D clouds. It is based on highly simplified 3D RT and exploits multi-angular suites of cloud images at high spatial resolution. Airborne sensors like AirMSPI readily acquire such data. The key element of the reconstruction algorithm is a sophisticated solution of the nonlinear inverse problem via linearization of the forward model and an iteration scheme supported, where necessary, by adaptive regularization. Currently, the demo uses a 2D setting to show how either vertical profiles or horizontal slices of the cloud can be accurately reconstructed

  18. MR imaging evaluation of congenital spine anomalies

    International Nuclear Information System (INIS)

    Bury, E.A.; Zimmerman, R.A.; Grossman, R.I.; Goldberg, H.I.; Bilaniuk, L.T.; Hackney, D.B.

    1987-01-01

    Over a 2-year period, 135 patients between the ages of 1 week and 18 years were examined with MR imaging for possible congenital anomalies of the spine and spinal cord. Tethered cords with various other associated pathologies such as lipomas and myelomeningoceles were found in 36 patients. The remaining abnormal examinations consisted of syrinxes, Chiari malformations, diastematomyelia, and conus masses. In 55 patients the studies were interpreted as normal. Of these, three were subsequently shown by surgery of myelography to be abnormal. The first had a thickened filum with a small epidermoid, the second a thickened filum, and the third, with only sagittal images, a diastematomyelia. Children presenting with symptoms highly suspicious for congenital abnormalities but with a normal MR study in multiple planes may still require further evaluation with myelography. Multiplanar MR examination in most instances will be a sufficient evaluation for congenital anomalies

  19. 3 T MR 3D fast imaging employing steady state acquisition demonstrating branches of intraparotid facial nerve, parotid duct, and relation with parotid tumors

    International Nuclear Information System (INIS)

    Li Yan; Li Chuanting; Zhang Dongsheng; Ai Bin; Zhang Weidong; Wu Lebin

    2010-01-01

    Objective: To investigate the usefulness of 3 T MRI 3D-FIESTA in the evaluation of the intraparotid components of the facial nerve and parotid duct, and compare them with surgical findings. Methods: Twenty-two cases with parotid benign tumors were scanned with conventional and 3D-FIESTA sequences on 3 T MRI scanner. Postprocessed multiplanar images were obtained with the workstation. Parotid ducts and facial nerves and tumors were identified on these images. The relationship of the tumors to the facial nerves and Parotid ducts was confirmed at surgery. Results: Various types of parotid benign tumors had their characteristics on 3 T MR imaging. Parotid benign tumors mainly showed hypo-intensity on T 1 WI in 21 cases, and hyper-intensity on T 2 WI in 22 cases. But on 3D-FIESTA images, they appeared hypointensity (10 cases) or high intensity (12 cases) due to different types. Facial nerves in parotid appeared as linear structures with hypo-inteusity. The indication of the main trunks were 16 and 18 cases for T 1 WI and T 2 WI images, while on 3D-FIESTA images, the main trunks and cervicofacial and temporofacial divisions of the facial nerves were found in 22, 21,22 cases. Parotid ducts appeared as structures with hypo-intensity on T 1 WI and hyper-intensity on multiplanar images (14, 20, 22 cases). Compared with surgical results, the main trunks of the facial nerve were correctly showed by 3D-FIESTA images in 20 cases. However, in 2 cases they were not located in the operation because of shifting. Conclusion: 3 T MR 3D-FIESTA imaging could depict the extracranial facial nerve and the parotid duct in the parotid gland, which is useful for preoperative evaluation of parotid gland tumors. (authors)

  20. Magnetic resonance imaging of elephantiasis neuromatosa

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, K.J.; Sully, L.; Preston, B.J. [Department of Radiology, University Hospital, Queen`s Medical Centre, Nottingham (United Kingdom); Ludman, C.N. [Department of Radiology, University Hospital, Queen`s Medical Centre, Nottingham (United Kingdom)]|[Division of Academic Radiology, University Hospital, Queen`s Medical Centre, Nottingham (United Kingdom)

    1998-12-01

    We present the case of a 43-year-old man with neurofibromatosis type 1 who developed elephantiasis neuromatosa of his left leg. The gross limb enlargement was extremely disfiguring, and resulted in such severe disability that he was only able to walk a very short distance using crutches. Previous debulking procedures had resulted in massive blood loss, and prior to attempting further surgical intervention MRI studies were requested. Taking advantage of the excellent tissue characterisation and multiplanar imaging capabilities of MRI, we were able to assess the extent of soft tissue and osseous involvement. The use of recently developed MR angiographic sequences enabled us to non-invasively provide detailed images to assess the relationship of the lesions to the major vessels, as well as the vascular supply and angiographic features of the lesions themselves. This article describes our MRI-based findings, which precluded debulking surgery in this unusual manifestation of neurofibromatosis. (orig.) With 6 figs., 23 refs.

  1. Magnetic resonance imaging of elephantiasis neuromatosa

    International Nuclear Information System (INIS)

    Stevens, K.J.; Sully, L.; Preston, B.J.; Ludman, C.N.

    1998-01-01

    We present the case of a 43-year-old man with neurofibromatosis type 1 who developed elephantiasis neuromatosa of his left leg. The gross limb enlargement was extremely disfiguring, and resulted in such severe disability that he was only able to walk a very short distance using crutches. Previous debulking procedures had resulted in massive blood loss, and prior to attempting further surgical intervention MRI studies were requested. Taking advantage of the excellent tissue characterisation and multiplanar imaging capabilities of MRI, we were able to assess the extent of soft tissue and osseous involvement. The use of recently developed MR angiographic sequences enabled us to non-invasively provide detailed images to assess the relationship of the lesions to the major vessels, as well as the vascular supply and angiographic features of the lesions themselves. This article describes our MRI-based findings, which precluded debulking surgery in this unusual manifestation of neurofibromatosis. (orig.)

  2. MR imaging of neuronal migration anomaly

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Choi, Eun Wan; Kim, Dae Ho; Chung, Moo Chan; Kwon, Kuy Hyang; Kim, Ki Jung

    1991-01-01

    Abnormalities of neuronal migration are characterized by anectopic location of neurons in the cerebral cortex. This broad group of anomalies includes agyria, pachygyria, schizencephaly, unilateral megalencephaly, and gray matter heterotopia. Patients with this anomaly present clinically with a variety of symptoms which are proportional to the extent of the brain involved. These abnormalities have characterized pathologically in vivo by sonography and CT scan. MR appears to be an imaging technique of choice in evaluating these anomalies because it is capable of exceptionally good differentiation between gray and white matter, high contrast resolution, multiplanar display of the anatomy, and lack of overlying bone artifac. The purpose of this paper is to describe the MR findings of neuronal migration anomaly. The results of our study support that MR appears to be the imaging method of choice for diagnosing migration anomalies and the primary screening method for infants or children who have seisure/and delayed development

  3. Magnetic resonance imaging of the abdomen and pelvis

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Magnetic resonance imaging (MRI) of the abdomen presents greater inherent difficulties than other anatomic regions. However, new techniques now allow imaging comparable in quality to computed tomography (CT). Magnetic resonance imaging offers the advantages of greater tissue contrast, multiplanar imaging, and lack of ionizing radiation or risk of toxic reactions from iodinated contrast media. Its use remains limited by high cost, limited availability, lack of a bowel contrast agent, and long imaging time, which some patients cannot tolerate. In many areas of abdominal imaging, MRI is now comparable to CT, but because of the greater availability and lesser cost, CT remains the procedure of choice. Magnetic resonance imaging is more accurate for staging neoplasms of the liver, adrenal glands, kidneys, bladder, prostate, uterus, and cervix and may aid in diagnosis of hepatic, adrenal, and uterine masses. In selected patients, especially those in whom CT is inconclusive or those who cannot tolerate iodinated contrast material, MRI can provide valuable information. Development of faster scanning techniques and MRI contrast agents and wider availability will probably increase the usefulness of abdominal MRI. At this time, MRI complements other abdominal imaging procedures. In a small number of patients, however, it can provide unique information in a virtually risk-free manner

  4. On Callan's proof of the BPHZ theorem

    International Nuclear Information System (INIS)

    Lesniewski, A.

    1984-01-01

    The author gives an elementary proof of the BPHZ theorem in the case of the Euclidean lambdaphi 4 theory. The method of proof relies on a detailed analysis of the skeleton structure of graphs and estimates based on the Callan-Symanzik equations. (Auth.)

  5. A survey of noninteractive zero knowledge proof system and its applications.

    Science.gov (United States)

    Wu, Huixin; Wang, Feng

    2014-01-01

    Zero knowledge proof system which has received extensive attention since it was proposed is an important branch of cryptography and computational complexity theory. Thereinto, noninteractive zero knowledge proof system contains only one message sent by the prover to the verifier. It is widely used in the construction of various types of cryptographic protocols and cryptographic algorithms because of its good privacy, authentication, and lower interactive complexity. This paper reviews and analyzes the basic principles of noninteractive zero knowledge proof system, and summarizes the research progress achieved by noninteractive zero knowledge proof system on the following aspects: the definition and related models of noninteractive zero knowledge proof system, noninteractive zero knowledge proof system of NP problems, noninteractive statistical and perfect zero knowledge, the connection between noninteractive zero knowledge proof system, interactive zero knowledge proof system, and zap, and the specific applications of noninteractive zero knowledge proof system. This paper also points out the future research directions.

  6. A Survey of Noninteractive Zero Knowledge Proof System and Its Applications

    Directory of Open Access Journals (Sweden)

    Huixin Wu

    2014-01-01

    Full Text Available Zero knowledge proof system which has received extensive attention since it was proposed is an important branch of cryptography and computational complexity theory. Thereinto, noninteractive zero knowledge proof system contains only one message sent by the prover to the verifier. It is widely used in the construction of various types of cryptographic protocols and cryptographic algorithms because of its good privacy, authentication, and lower interactive complexity. This paper reviews and analyzes the basic principles of noninteractive zero knowledge proof system, and summarizes the research progress achieved by noninteractive zero knowledge proof system on the following aspects: the definition and related models of noninteractive zero knowledge proof system, noninteractive zero knowledge proof system of NP problems, noninteractive statistical and perfect zero knowledge, the connection between noninteractive zero knowledge proof system, interactive zero knowledge proof system, and zap, and the specific applications of noninteractive zero knowledge proof system. This paper also points out the future research directions.

  7. Curved planar reconstruction of MR images in focal cortical dysplasia of the brain

    International Nuclear Information System (INIS)

    Chung, Gyung Ho; Lee, Sang Yong; Kim, Chong So; Kim, Young Kon; Lee, Young Hwan; Jeong, Su Hyun

    2002-01-01

    To describe curved planar reconstruction imaging (CPR) and determine its usefulness in the evaluation of focal cortical dysplasia of the brain. In 17 cases of focal cortical dysplasia (cortical dysplasia (n=9), schizencephaly (n=5), and heterotopia (n=3), CPR images were created using a multiplanar reconstruction program and imaging data obtained during T1 magnetization prepared rapid acquisition gradient-echo MR imaging. We assessed the precise configuration of abnormalities and their relation to adjacent gyri and sulci. CPRI showed the brain cortex as a 2D panoramic image, demonstrating the precise configurations and locations of dysplasia-associated abnormalities and their relation to adjacent gyri and sulci, and the precise shape of the gray-white matter interface. CPRI can provide important radiological information about the extension and configuration of focal cortical dysplasia, and its relation to neighboring cortical structures. We believe that CPRI should form an essential part of the routine investigation os suspected cases of focal cortical dysplasia

  8. An illustration of the explanatory and discovery functions of proof

    Directory of Open Access Journals (Sweden)

    Michael de Villiers

    2012-11-01

    Full Text Available This article provides an illustration of the explanatory and discovery functions of proof with an original geometric conjecture made by a Grade 11 student. After logically explaining (proving the result geometrically and algebraically, the result is generalised to other polygons by further reflection on the proof(s. Different proofs are given, each giving different insights that lead to further generalisations. The underlying heuristic reasoning is carefully described in order to provide an exemplar for designing learning trajectories to engage students with these functions of proof.

  9. A Concise and Direct Proof of "Fermat's Last Theorem"

    OpenAIRE

    Ellman, Roger

    1998-01-01

    The recently developed proof of Fermat's Last Theorem is very lengthy and difficult, so much so as to be beyond all but a small body of specialists. While certainly of value in the developments that resulted, that proof could not be, nor was offered as being, possibly the proof Fermat had in mind. The present proof being brief, direct and concise is a candidate for being what Fermat had in mind. It is also completely accessible to any one trained in common algebra. That critical suggestions o...

  10. 28 CFR 79.35 - Proof of onset of leukemia at least two years after first exposure, and proof of onset of a...

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Proof of onset of leukemia at least two... Participants § 79.35 Proof of onset of leukemia at least two years after first exposure, and proof of onset of... be the date of first or initial exposure. The date of onset will be the date of diagnosis as...

  11. Earthquake proof device for nuclear power plant building

    International Nuclear Information System (INIS)

    Okada, Yasuo.

    1991-01-01

    The structure of the present invention enables three dimensional vibration proof, i.e., in horizontal and vertical directions of a reactor container building. That is, each of the reactor container building and a reactor auxiliary building is adapted as an independent structure. The periphery of the reactor container building is surrounded by the reactor auxiliary building. The reactor auxiliary building is supported against the ground by way of a horizontal vibration proof device. The reactor container building is supported against the ground by way of a three-dimensional vibration proof device that prevents vibrations in both of the horizontal directions, and the vertical directions. The reactor container building is connected to the auxiliary building by way of a vertical vibration proof device. With such a constitution, although the reactor container building is vibration proof against both of the horizontal and the vertical vibrations, the vertical vibration proofness is an extension of inherent vertical vibration period. Accordingly, the head of the building undergoes rocking vibrations. However, since the reactor container building is connected to the reactor auxiliary building, the rocking vibrations are prevented by the reactor auxiliary building. As a result, safety upon occurrence of an earthquakes can be ensured. (I.S.)

  12. Interventional magnetic resonance imaging - non-invasive imaging for interventions; Interventionelle Magnetresonanztomographie - nichtinvasive Bildgebung fuer Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A.; Adam, G.; Neuerburg, J.M.; Glowinski, A.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Medizinische Fakultaet

    2000-02-01

    As a prerequisite for MR-guidance of interventional procedures, instruments have to be well depicted in the MR image without obscuring or distorting the underlying anatomy. For non-vascular interventions the imaging speed has to be in the range of seconds while control of vascular interventions requires real time imaging speed. The imaging contrast has to be maintained as well as a high spatial resolution. Furthermore, sufficient patient access has to be provided by the MR scanner. Neither an ideal magnet nor the optimal single sequence are available to fulfill the above-mentioned criteria. The type of sequence - gradient echo versus spin echo - together with changing of the echo time and phase encording direction will ensure an appropriate size of the artifact and thereby of the appearance of the instrument in the MR image. The feasibility of non-vascular MR-guided interventions has been proved at field strengths ranging from 0.064 T to 1.5 T. Bone biopsies, soft tissue biopsies, drainages, and control of interstitial thermo- and cryotherapy have been reported. For vascular interventions, different real time MR strategies are currently under investigation. The development of dedicated catheters and guide wires has enabled MR-guided dilatations, stenting, placement of vena cava filters, and TIPS procedures. Considering the fast progress being made in this field, there can be no question that interventional MRI will become a well-accepted clinical tool offering potential advantages such as excellent soft tissue contrast, multiplanar imaging, flow measurements, high resolution imaging of vessel walls, and lack of ionizing radiation. (orig.) [German] Zur Durchfuehrung MR-gesteuerter Interventionen muessen interventionelle Instrumente gut sichtbar, aber ohne stoerende Artefakte darstellbar sein. Die Geschwindigkeit der Bilderstellung sollte fuer nichtvaskulaere Interventionen im Sekundenbereich liegen und fuer vaskulaere Interventionen Echtzeitbildgebung liefern. Weder

  13. 28 CFR 79.13 - Proof of physical presence for the requisite period and proof of participation onsite during a...

    Science.gov (United States)

    2010-07-01

    ... participated onsite in the atmospheric detonation of a nuclear device. ... requisite period and proof of participation onsite during a period of atmospheric nuclear testing. 79.13... presence for the requisite period and proof of participation onsite during a period of atmospheric nuclear...

  14. Symbolic logic syntax, semantics, and proof

    CERN Document Server

    Agler, David

    2012-01-01

    Brimming with visual examples of concepts, derivation rules, and proof strategies, this introductory text is ideal for students with no previous experience in logic. Students will learn translation both from formal language into English and from English into formal language; how to use truth trees and truth tables to test propositions for logical properties; and how to construct and strategically use derivation rules in proofs.

  15. Data-oriented scheduling for PROOF

    International Nuclear Information System (INIS)

    Xu Neng; Guan Wen; Wu Sau Lan; Ganis, Gerardo

    2011-01-01

    The Parallel ROOT Facility - PROOF - is a distributed analysis system optimized for I/O intensive analysis tasks of HEP data. With LHC entering the analysis phase, PROOF has become a natural ingredient for computing farms at Tier3 level. These analysis facilities will typically be used by a few tenths of users, and can also be federated into a sort of analysis cloud corresponding to the Virtual Organization of the experiment. Proper scheduling is required to guarantee fair resource usage, to enforce priority policies and to optimize the throughput. In this paper we discuss an advanced priority system that we are developing for PROOF. The system has been designed to automatically adapt to unknown length of the tasks, to take into account the data location and availability (including distribution across geographically separated sites), and the {group, user} default priorities. In this system, every element - user, group, dataset, job slot and storage - gets its priority and those priorities are dynamically linked with each other. In order to tune the interplay between the various components, we have designed and started implementing a simulation application that can model various type and size of PROOF clusters. In this application a monitoring package records all the changes of them so that we can easily understand and tune the performance. We will discuss the status of our simulation and show examples of the results we are expecting from it.

  16. Verifying Process Algebra Proofs in Type Theory

    NARCIS (Netherlands)

    Sellink, M.P.A.

    In this paper we study automatic verification of proofs in process algebra. Formulas of process algebra are represented by types in typed λ-calculus. Inhabitants (terms) of these types represent proofs. The specific typed λ-calculus we use is the Calculus of Inductive Constructions as implemented

  17. Non-Well-Founded Proofs for the Grzegorczyk Modal Logic

    OpenAIRE

    Savateev, Yury; Shamkanov, Daniyar

    2018-01-01

    We present a sequent calculus for the Grzegorczyk modal logic Grz allowing cyclic and other non-well-founded proofs and obtain the cut-elimination theorem for it by constructing a continuous cut-elimination mapping acting on these proofs. As an application, we establish the Lyndon interpolation property for the logic Grz proof-theoretically.

  18. Mathematicians' Perspectives on Features of a Good Pedagogical Proof

    Science.gov (United States)

    Lai, Yvonne; Weber, Keith; Mejia-Ramos, Juan Pablo

    2012-01-01

    In this article, we report two studies investigating what mathematicians value in a pedagogical proof. Study 1 is a qualitative study of how eight mathematicians revised two proofs that would be presented in a course for mathematics majors. These mathematicians thought that introductory and concluding sentences should be included in the proofs,…

  19. A Calculus of Circular Proofs and its Categorical Semantics

    DEFF Research Database (Denmark)

    Santocanale, Luigi

    2002-01-01

    We present a calculus of "circular proofs": the graph underlying a proof is not a finite tree but instead it is allowed to contain a certain amount of cycles.The main challenge in developing a theory for the calculus is to define the semantics of proofs, since the usual method by induction...

  20. Proof of payment for all reimbursement claims

    CERN Multimedia

    HR Department

    2006-01-01

    Members of the personnel are kindly requested to note that only documents proving that a payment has been made are accepted as proof of payment for any claims for reimbursement, including specifically the reimbursement of education fees. In particular, the following will be accepted as proof of payment: bank or post office bank statements indicating the name of the institution to which the payment was made; photocopies of cheques made out to the institution to which the payments were made together with bank statements showing the numbers of the relevant cheques; proof of payment in the form of discharged payment slips; invoices with acknowledgement of settlement, receipts, bank statements detailing operations crediting another account or similar documents. As a result, the following documents in particular will no longer be accepted as proof of payment: photocopies of cheques that are not submitted together with bank or post office bank statements showing the numbers of the relevant cheques; details of ...

  1. Problems and proofs in numbers and algebra

    CERN Document Server

    Millman, Richard S; Kahn, Eric Brendan

    2015-01-01

    Designed to facilitate the transition from undergraduate calculus and differential equations to learning about proofs, this book helps students develop the rigorous mathematical reasoning needed for advanced courses in analysis, abstract algebra, and more. Students will focus on both how to prove theorems and solve problem sets in-depth; that is, where multiple steps are needed to prove or solve. This proof technique is developed by examining two specific content themes and their applications in-depth: number theory and algebra. This choice of content themes enables students to develop an understanding of proof technique in the context of topics with which they are already familiar, as well as reinforcing natural and conceptual understandings of mathematical methods and styles. The key to the text is its interesting and intriguing problems, exercises, theorems, and proofs, showing how students will transition from the usual, more routine calculus to abstraction while also learning how to “prove” or “sol...

  2. On the burden of proof in civil procedure

    Directory of Open Access Journals (Sweden)

    Keča Ranko

    2013-01-01

    Full Text Available The appliance of burden of proof rules is conceived of assumption that evidences are taken and that court didn't reach the required degree of conviction of a particular fact, what implies limitation of application of these rules on proceedings in which the judgment is rendered after the plenary proceedings. The Code of Civil Procedure (CCP has no suitable answers for the problems arising from new conception of the principle of party control of facts and means of proof in Serbian litigation legislature, by which the court has no more power to take the evidence ex offo. There is no answer to the question how should court conduct when evidence is not taken because of a lack of parties' indication of the means of proof. In this case courts practice somehow wider conception of burden of proof rules, which however has no explicit legal ground. They are applying them even though evidences are not taken. In any case it would be useful to reformulate basic rule of burden of proof in manner which would correspondent to the new conception of the principle of party presentation. The rule of burden of proof applies when the high degree of conviction of facts is demanded from the court, in order to render the judgment. Consequently this rule loses its' sense when mere probability of factual findings is demanded. The broader conception of parties' representation principle however does not liberate court from his responsibility to clarify facts that should be base for adjudication. Circumstance that CCP does mention the principle of material truth anymore should not be seen as argument for liberation of mentioned responsibility. It is still expected from the court to be active. Only when joint effort of the court and parties is left without of goal, in sense that court doesn't reach the high degree conviction, there would be ground for burden of proof rule's application. In this situation court also must justify why he couldn't reach required degree of

  3. Semantic Contamination and Mathematical Proof: Can a Non-Proof Prove?

    Science.gov (United States)

    Mejia-Ramos, Juan Pablo; Inglis, Matthew

    2011-01-01

    The way words are used in natural language can influence how the same words are understood by students in formal educational contexts. Here we argue that this so-called semantic contamination effect plays a role in determining how students engage with mathematical proof, a fundamental aspect of learning mathematics. Analyses of responses to…

  4. MR imaging of congenital heart diseases in adolescents and adults

    International Nuclear Information System (INIS)

    Choe, Yeon Hyeon; Kang, I Seok; Park, Seung Woo; Lee, Heung Jae

    2001-01-01

    Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults

  5. Magnetic particle imaging: from proof of principle to preclinical applications

    Science.gov (United States)

    Knopp, T.; Gdaniec, N.; Möddel, M.

    2017-07-01

    Tomographic imaging has become a mandatory tool for the diagnosis of a majority of diseases in clinical routine. Since each method has its pros and cons, a variety of them is regularly used in clinics to satisfy all application needs. Magnetic particle imaging (MPI) is a relatively new tomographic imaging technique that images magnetic nanoparticles with a high spatiotemporal resolution in a quantitative way, and in turn is highly suited for vascular and targeted imaging. MPI was introduced in 2005 and now enters the preclinical research phase, where medical researchers get access to this new technology and exploit its potential under physiological conditions. Within this paper, we review the development of MPI since its introduction in 2005. Besides an in-depth description of the basic principles, we provide detailed discussions on imaging sequences, reconstruction algorithms, scanner instrumentation and potential medical applications.

  6. On the proof of the first Carnot theorem in thermodynamics

    International Nuclear Information System (INIS)

    Morad, M R; Momeni, F

    2013-01-01

    The proof of the first Carnot theorem in classical thermodynamics is revisited in this study. The underlying conditions of a general proof of this principle presented by Senft (1978 Phys. Educ. 13 35–37) are explored and discussed. These conditions are analysed in more detail using a physical description of heat and work to present a simpler proof of the first principle prior to using the violation of the second law of thermodynamics. Finally, a new simple proof is also presented based on Gibbs relation. This discussion will benefit the teaching of classical thermodynamics and promote better understanding of the proof of the first Carnot theorem in general form. (paper)

  7. Construction of state-independent proofs for quantum contextuality

    Science.gov (United States)

    Tang, Weidong; Yu, Sixia

    2017-12-01

    Since the enlightening proofs of quantum contextuality first established by Kochen and Specker, and also by Bell, various simplified proofs have been constructed to exclude the noncontextual hidden variable theory of our nature at the microscopic scale. The conflict between the noncontextual hidden variable theory and quantum mechanics is commonly revealed by Kochen-Specker sets of yes-no tests, represented by projectors (or rays), via either logical contradictions or noncontextuality inequalities in a state-(in)dependent manner. Here we propose a systematic and programmable construction of a state-independent proof from a given set of nonspecific rays in C3 according to their Gram matrix. This approach brings us a greater convenience in the experimental arrangements. Besides, our proofs in C3 can also be generalized to any higher-dimensional systems by a recursive method.

  8. Adapting proofs-as-programs the Curry-Howard protocol

    CERN Document Server

    Poernomo, Iman Hafiz; Crossley, John Newsome

    2007-01-01

    Details developments in the direction of a practical proofs-as-programs paradigm, which constitutes a set of approaches to developing programs from proofs in constructive logic with applications to industrial-scale, complex software engineering problems.

  9. 14 CFR 406.155 - Offer of proof.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Offer of proof. 406.155 Section 406.155... Transportation Adjudications § 406.155 Offer of proof. A party whose evidence has been excluded by a ruling of the administrative law judge may offer the evidence for the record on appeal. ...

  10. Interval logic. Proof theory and theorem proving

    DEFF Research Database (Denmark)

    Rasmussen, Thomas Marthedal

    2002-01-01

    of a direction of an interval, and present a sound and complete Hilbert proof system for it. Because of its generality, SIL can conveniently act as a general formalism in which other interval logics can be encoded. We develop proof theory for SIL including both a sequent calculus system and a labelled natural...

  11. 14 CFR 25.307 - Proof of structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Proof of structure. 25.307 Section 25.307... STANDARDS: TRANSPORT CATEGORY AIRPLANES Structure General § 25.307 Proof of structure. (a) Compliance with... condition. Structural analysis may be used only if the structure conforms to that for which experience has...

  12. 14 CFR 23.307 - Proof of structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Proof of structure. 23.307 Section 23.307... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure General § 23.307 Proof of structure. (a) Compliance with the strength and deformation requirements of § 23.305 must be shown for each...

  13. MR imaging of abscess by use of lipid-coated iron oxide particles

    International Nuclear Information System (INIS)

    Chan, T.W.; Eley, C.G.S.; Kressel, H.Y.

    1990-01-01

    The authors of this paper investigate the potential application of lipid-coated iron oxide particles as an MR contrast agent for imaging inflammatory process by using a rat subcutaneous abscess model induced by turpentine. Ten male Sprague-Dawley rats received subcutaneous injections of 0.1 mL of turpentine in the flank. At 24-36 hours later, the rats developed a subcutaneous abscess of 1-1.8 cm. An intravenous injection of lipid-coated iron oxide particles, Ferrosome (Vestar) at doses of 25, 40, 100, 200 μg/kg was administered. The animals were imaged at 12-24 hours later on a 1.5-T magnet using a 3-inch (7.62-cm) surface coil. Two animals were also imaged 5 days later. T1-weighted, T2-weighted, and multiplanar gradient-recalled (MPGR) sequences were obtained. The abscess was then excised and examined with routine H-E and iron staining

  14. Endometrial cancer: magnetic resonance imaging.

    Science.gov (United States)

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  15. Autonomous intelligent cars: proof that the EPSRC Principles are future-proof

    NARCIS (Netherlands)

    de Bruin, R.W.; de Cock Buning, M.

    2017-01-01

    Principle 2 of the EPSRC’s principles of robotics (AISB workshop on PrinciplesofRobotics, 2016) proves to be future proof when applied to the current state of the art of law and technology surrounding autonomous intelligent cars (AICs). Humans, not AICS, are responsible agents. AICs should be

  16. Towards a comprehensive knowledge package for teaching proof: A focus on the misconception that empirical arguments are proofs

    Directory of Open Access Journals (Sweden)

    Andreas J. Stylianides

    2011-08-01

    Full Text Available The concept of proof is central to meaningful learning of mathematics, but is hard for students to learn. A serious misconception dominant amongst students at all levels of schooling is that empirical arguments are proofs. An important question, then, is the following: What knowledge might enable teachers to help students overcome this misconception? Earlier research led to construction of a significant but rather incomplete ‘knowledge package’ for teaching in this area. Major elements of this knowledge package are summarised and its further development is contributed to by discussing a research-based instructional intervention found to be effective in helping secondary students begin to overcome the misconception that empirical arguments are proofs. Implications for mathematics teacher education are considered.

  17. Proof, rigour and informality : a virtue account of mathematical knowledge

    OpenAIRE

    Tanswell, Fenner Stanley

    2017-01-01

    This thesis is about the nature of proofs in mathematics as it is practiced, contrasting the informal proofs found in practice with formal proofs in formal systems. In the first chapter I present a new argument against the Formalist-Reductionist view that informal proofs are justified as rigorous and correct by corresponding to formal counterparts. The second chapter builds on this to reject arguments from Gödel's paradox and incompleteness theorems to the claim that mathematics is inherently...

  18. Advanced large airway CT imaging in children: evolution from axial to 4-D assessment

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Zucker, Evan J.; Restrepo, Ricardo; Daltro, Pedro; Boiselle, Phillip M.

    2013-01-01

    Continuing advances in multidetector computed tomography (MDCT) technology are revolutionizing the non-invasive evaluation of congenital and acquired large airway disorders in children. For example, the faster scanning time and increased anatomical coverage that are afforded by MDCT are especially beneficial to children. MDCT also provides high-quality multiplanar 2-dimensional (2-D), internal and external volume-rendering 3-dimensional (3-D), and dynamic 4-dimensional (4-D) imaging. These advances have enabled CT to become the primary non-invasive imaging modality of choice for the diagnosis, treatment planning, and follow-up evaluation of various large airway disorders in infants and children. It is thus essential for radiologists to be familiar with safe and effective techniques for performing MDCT and to be able to recognize the characteristic imaging appearances of large airway disorders affecting children. (orig.)

  19. 14 CFR 16.231 - Offer of proof.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Offer of proof. 16.231 Section 16.231... PRACTICE FOR FEDERALLY-ASSISTED AIRPORT ENFORCEMENT PROCEEDINGS Hearings § 16.231 Offer of proof. A party whose evidence has been excluded by a ruling of the hearing officer may offer the evidence on the record...

  20. 49 CFR 1503.641 - Offer of proof.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Offer of proof. 1503.641 Section 1503.641... Rules of Practice in TSA Civil Penalty Actions § 1503.641 Offer of proof. A party whose evidence has been excluded by a ruling of the ALJ may offer the evidence for the record on appeal. ...

  1. Characterization of impact damage in metallic/nonmetallic composites using x-ray computed tomography imaging

    International Nuclear Information System (INIS)

    Green, William H.; Wells, Joseph M.

    1999-01-01

    Characterizing internal impact damage in composites can be difficult, especially in structurally complex composites or those consisting of many materials. Many methods for nondestructive inspection/nondestructive testing (NDI/NDT) of materials have been known and in use for many years, including x-ray film, real-time, and digital radiographic techniques, and ultrasonic techniques. However, these techniques are generally not capable of three-dimensional (3D) mapping of complex damage patterns, which is necessary to visualize and understand damage cracking modes. Conventional x-ray radiography suffers from the loss of 3D information. Structural complexity and signal dispersion in materials with many interfaces significantly effect ultrasonic inspection techniques. This makes inspection scan interpretation difficult, especially in composites containing a number of different materials (i.e., polymer, ceramic, and metallic). X-ray computed tomography (CT) is broadly applicable to any material or test object through which a beam of penetrating radiation may be passed and detected, including metals, plastics, ceramics, metallic/nonmetallic composites, and assemblies. The principal advantage of CT is that it provides densitometric (that is, radiological density and geometry) images of thin cross sections through an object. Because of the absence of structural superposition, images are much easier to interpret than conventional radiological images. The user can quickly learn to read CT data because images correspond more closely to the way the human mind visualizes 3D structures than projection radiology (that is, film radiography, real-time radiography (RTR), and digital radiography (DR)). Any number of CT images, or slices, from scanning an object can be volumetrically reconstructed to produce a 3D attenuation map of the object. The 3D attenuation data can be rendered using multiplanar or 3D solid visualization. In multiplanar visualization there are four planes of view

  2. [Burden of proof in medical cases--presumption of fact and prima facie evidence. 1. Burden of proof].

    Science.gov (United States)

    Sliwka, Marcin

    2004-01-01

    The aim of this paper was to present the main rules concerning the burden of proof in polish civil trials, including medical cases. This paper also describes the subject of evidence were presented and explained. The court influence on evidence procedure was also analysed. The effect of the institution of informed consent on burden of proof in polish civil law is also described. This paper includes numerous High Court sentences on evidential and medical issues.

  3. Visualizing Probabilistic Proof

    OpenAIRE

    Guerra-Pujol, Enrique

    2015-01-01

    The author revisits the Blue Bus Problem, a famous thought-experiment in law involving probabilistic proof, and presents simple Bayesian solutions to different versions of the blue bus hypothetical. In addition, the author expresses his solutions in standard and visual formats, i.e. in terms of probabilities and natural frequencies.

  4. MR defecography at 1.5 Tesla with radial real-time imaging at a reduced FOV

    International Nuclear Information System (INIS)

    Tacke, J.; Nolte-Ernsting, C.; Glowinski, A.; Adam, G.; Guenther, R.W.

    1999-01-01

    Purpose: To evaluate a new technique for MR defecography with real-time imaging using radial k-space profiles. Materials and Methods: A catheter-mounted condom was inserted into the rectum of 16 patients and filled in situ by a mixture of Nestargel trademark and Gadolinium. After multiplanar imaging of the pelvis by high resolution T 2 -weighted turbo-spin echo sequences, defecation was imaged by a gradient echo sequence with radial k-space filling using a reduced field of view (rFOV) in real-time. The documentation was performed on an S-VHS recorder. Results: At a constant background signal, radial k-space filling yields a real-time impression. An interactive software allowed the operator to modify the slice thickness, slice plane, flip angle and slice angulation during scanning, resulting in an optimum imaging quality of the defecation. Conclusions: This new imaging technique allows real-time MR defecography in a high-field scanner and provides all anatomical and functional information of the defecation. (orig.) [de

  5. On Mathematicians' Proof Skimming: A Reply to Inglis and Alcock

    Science.gov (United States)

    Weber, Keith; Mejia-Ramos, Juan Pablo

    2013-01-01

    n a recent article, Inglis and Alcock (2012) contended that their data challenge the claim that when mathematicians validate proofs, they initially skim a proof to grasp its main idea before reading individual parts of the proof more carefully. This result is based on the fact that when mathematicians read proofs in their study, on average their…

  6. 14 CFR 13.225 - Offer of proof.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Offer of proof. 13.225 Section 13.225... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Rules of Practice in FAA Civil Penalty Actions § 13.225 Offer of proof. A party whose evidence has been excluded by a ruling of the administrative law judge may offer the...

  7. 34 CFR 34.14 - Burden of proof.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Burden of proof. 34.14 Section 34.14 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.14 Burden of proof. (a... those in § 34.24. (d)(1) If you object on the ground that applicable law bars us from collecting the...

  8. Visual Considerations in the Presentation of Mathematical Proofs

    Directory of Open Access Journals (Sweden)

    Lara Alcock

    2010-11-01

    Full Text Available This article is about visual issues in the presentation of mathematics within teaching situations. It focuses particularly on the presentation of proofs to undergraduate students. We describe some of the decisions that a lecturer must make when presenting a written proof, from the layout of individual equations to the layout of a whole argument on the page. We consider the way in which these decisions are made explicit for lecturers who construct electronic learning resources termed e-Proofs, and conclude by discussing the constraints and affordances of this technology.

  9. Co-constructive Logics for Proofs and Refutations

    Directory of Open Access Journals (Sweden)

    Trafford James

    2015-01-01

    Full Text Available This paper considers logics which are formally dual to intuitionistic logic in order to investigate a co-constructive logic for proofs and refutations. This is philosophically motivated by a set of problems regarding the nature of constructive truth, and its relation to falsity. It is well known both that intuitionism can not deal constructively with negative information, and that defining falsity by means of intuitionistic negation leads, under widely-held assumptions, to a justification of bivalence. For example, we do not want to equate falsity with the non-existence of a proof since this would render a statement such as “pi is transcendental” false prior to 1882. In addition, the intuitionist account of negation as shorthand for the derivation of absurdity is inadequate, particularly outside of purely mathematical contexts. To deal with these issues, I investigate the dual of intuitionistic logic, co-intuitionistic logic, as a logic of refutation, alongside intuitionistic logic of proofs. Direct proof and refutation are dual to each other, and are constructive, whilst there also exist syntactic, weak, negations within both logics. In this respect, the logic of refutation is weakly paraconsistent in the sense that it allows for statements for which, neither they, nor their negation, are refuted. I provide a proof theory for the co-constructive logic, a formal dualizing map between the logics, and a Kripke-style semantics. This is given an intuitive philosophical rendering in a re-interpretation of Kolmogorov's logic of problems.

  10. Gödel's Proof

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 5. Gödel's Proof - Incompleteness Theorems. S M Srivastava. General Article Volume 12 Issue 5 May 2007 pp 71-84. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/012/05/0071-0084. Keywords.

  11. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  12. 41 CFR 60-30.19 - Objections; exceptions; offer of proof.

    Science.gov (United States)

    2010-07-01

    ... exceptions to the Administrative Law Judge's recommendations and conclusions. (c) Offer of proof. An offer of...; offer of proof. 60-30.19 Section 60-30.19 Public Contracts and Property Management Other Provisions... EXECUTIVE ORDER 11246 Hearings and Related Matters § 60-30.19 Objections; exceptions; offer of proof. (a...

  13. A simple proof of Debreu's Gap Lemma | Ouwehand | ORiON

    African Journals Online (AJOL)

    Debreu's Gap Lemma is central to the proof of his fundamental result on the existence of continuous utility functions. A short proof based on a standard textbook construction of utility functions on countable linearly ordered sets is presented here. The proof is accessible to students with limited mathematical background, thus ...

  14. Proof of principle study of the use of a CMOS active pixel sensor for proton radiography.

    Science.gov (United States)

    Seco, Joao; Depauw, Nicolas

    2011-02-01

    Proof of principle study of the use of a CMOS active pixel sensor (APS) in producing proton radiographic images using the proton beam at the Massachusetts General Hospital (MGH). A CMOS APS, previously tested for use in s-ray radiation therapy applications, was used for proton beam radiographic imaging at the MGH. Two different setups were used as a proof of principle that CMOS can be used as proton imaging device: (i) a pen with two metal screws to assess spatial resolution of the CMOS and (ii) a phantom with lung tissue, bone tissue, and water to assess tissue contrast of the CMOS. The sensor was then traversed by a double scattered monoenergetic proton beam at 117 MeV, and the energy deposition inside the detector was recorded to assess its energy response. Conventional x-ray images with similar setup at voltages of 70 kVp and proton images using commercial Gafchromic EBT 2 and Kodak X-Omat V films were also taken for comparison purposes. Images were successfully acquired and compared to x-ray kVp and proton EBT2/X-Omat film images. The spatial resolution of the CMOS detector image is subjectively comparable to the EBT2 and Kodak X-Omat V film images obtained at the same object-detector distance. X-rays have apparent higher spatial resolution than the CMOS. However, further studies with different commercial films using proton beam irradiation demonstrate that the distance of the detector to the object is important to the amount of proton scatter contributing to the proton image. Proton images obtained with films at different distances from the source indicate that proton scatter significantly affects the CMOS image quality. Proton radiographic images were successfully acquired at MGH using a CMOS active pixel sensor detector. The CMOS demonstrated spatial resolution subjectively comparable to films at the same object-detector distance. Further work will be done in order to establish the spatial and energy resolution of the CMOS detector for protons. The

  15. A String of Pearls: Proofs of Fermat's Little Theorem

    Directory of Open Access Journals (Sweden)

    Hing Lun Chan

    2013-01-01

    Full Text Available We discuss mechanised proofs of Fermat's Little Theorem in a variety of styles, focusing in particular on an elegant combinatorial ``necklace'' proof that has not been mechanised previously.What is elegant in prose turns out to be long-winded mechanically, and so we examine the effect of explicitly appealing to group theory. This has pleasant consequences both for the necklace proof, and also for some of the direct number-theoretic approaches.

  16. Another proof of Gell-Mann and Low's theorem

    OpenAIRE

    Molinari, Luca Guido

    2006-01-01

    The theorem by Gell-Mann and Low is a cornerstone in QFT and zero-temperature many-body theory. The standard proof is based on Dyson's time-ordered expansion of the propagator; a proof based on exact identities for the time-propagator is here given.

  17. 16 CFR 23.10 - Misuse of “corrosion proof,” “noncorrosive,” “corrosion resistant,” “rust proof,” “rust resistant...

    Science.gov (United States)

    2010-01-01

    ... INDUSTRIES § 23.10 Misuse of “corrosion proof,” “noncorrosive,” “corrosion resistant,” “rust proof,” “rust resistant,” etc. (a) It is unfair or deceptive to: (1) Use the terms “corrosion proof,” “noncorrosive... the product will be immune from rust and other forms of corrosion during the life expectancy of the...

  18. Meningiomas parasselares: aspectos na ressonância magnética Parasellar meningiomas: magnetic resonance imaging findings

    Directory of Open Access Journals (Sweden)

    Alair Augusto S.M.D. dos Santos

    2001-02-01

    Full Text Available Foram revistos 22 casos de meningiomas parasselares avaliados por ressonância magnética em clínicas privadas nas cidades de Niterói e Rio de Janeiro, RJ. O objetivo deste trabalho é demonstrar os aspectos de imagem encontrados neste tumor. Os equipamentos utilizados tinham 0,5 e 1,0 Tesla, respectivamente, com aquisição de seqüências multiplanares ponderadas em T1 (antes e após a administração de gadolínio e em T2. Os sintomas principais foram cefaléia e alterações visuais, tendo apenas um caso cursado com hiperprolactinemia. O aspecto mais freqüente foi o de massa parasselar hipointensa em T1 e hiperintensa em T2, impregnando-se intensamente pelo gadolínio. A ressonância magnética é útil não apenas na demonstração da lesão mas, sobretudo, na avaliação do comprometimento das estruturas vizinhas, especialmente do seio cavernoso, o que explica as alterações visuais encontradas.We reviewed 22 cases of patients with parasellar meningiomas evaluated with magnetic resonance imaging (MRI in private clinics of the cities of Niterói and Rio de Janeiro, RJ, Brazil. Our aim was to characterize the imaging findings in this type of tumor. MRI scanners with 0.5 and 1.0 Tesla magnets were used for the acquisition of multiplanar T1-weighted (pre- and post-gadolinium administration and T2-weighted images. The main symptoms observed were headache and visual disturbances. Hyperprolactinemia was observed in only one patient. The most frequent imaging finding was a parasellar mass which appeared hypointense on T1-weighted and hyperintense on T2-weighted images, and enhanced intensively after gadolinium administration. MRI is useful to demonstrate the lesion and to assess the damage to adjacent structures, particularly when the patient presents visual disturbances due to involvement of the cavernous sinuses.

  19. A model-based radiography restoration method based on simple scatter-degradation scheme for improving image visibility

    Science.gov (United States)

    Kim, K.; Kang, S.; Cho, H.; Kang, W.; Seo, C.; Park, C.; Lee, D.; Lim, H.; Lee, H.; Kim, G.; Park, S.; Park, J.; Kim, W.; Jeon, D.; Woo, T.; Oh, J.

    2018-02-01

    In conventional planar radiography, image visibility is often limited mainly due to the superimposition of the object structure under investigation and the artifacts caused by scattered x-rays and noise. Several methods, including computed tomography (CT) as a multiplanar imaging modality, air-gap and grid techniques for the reduction of scatters, phase-contrast imaging as another image-contrast modality, etc., have extensively been investigated in attempt to overcome these difficulties. However, those methods typically require higher x-ray doses or special equipment. In this work, as another approach, we propose a new model-based radiography restoration method based on simple scatter-degradation scheme where the intensity of scattered x-rays and the transmission function of a given object are estimated from a single x-ray image to restore the original degraded image. We implemented the proposed algorithm and performed an experiment to demonstrate its viability. Our results indicate that the degradation of image characteristics by scattered x-rays and noise was effectively recovered by using the proposed method, which improves the image visibility in radiography considerably.

  20. How Mathematicians Determine if an Argument Is a Valid Proof

    Science.gov (United States)

    Weber, Keith

    2008-01-01

    The purpose of this article is to investigate the mathematical practice of proof validation--that is, the act of determining whether an argument constitutes a valid proof. The results of a study with 8 mathematicians are reported. The mathematicians were observed as they read purported mathematical proofs and made judgments about their validity;…

  1. The quadratic reciprocity law a collection of classical proofs

    CERN Document Server

    Baumgart, Oswald

    2015-01-01

    This book is the English translation of Baumgart’s thesis on the early proofs of the quadratic reciprocity law (“Über das quadratische Reciprocitätsgesetz. Eine vergleichende Darstellung der Beweise”), first published in 1885. It is divided into two parts. The first part presents a very brief history of the development of number theory up to Legendre, as well as detailed descriptions of several early proofs of the quadratic reciprocity law. The second part highlights Baumgart’s comparisons of the principles behind these proofs. A current list of all known proofs of the quadratic reciprocity law, with complete references, is provided in the appendix. This book will appeal to all readers interested in elementary number theory and the history of number theory.

  2. Another proof of Gell-Mann and Low's theorem

    International Nuclear Information System (INIS)

    Molinari, Luca Guido

    2007-01-01

    The theorem by Gell-Mann and Low is a cornerstone in quantum field theory and zero-temperature many-body theory. The standard proof is based on Dyson's time-ordered expansion of the propagator; a proof based on exact identities for the time propagator is here given

  3. Congenital frontonasal masses: developmental anatomy, malformations, and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hedlund, Gary [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States)

    2006-07-15

    The newborn, infant, or young child who presents with a midline frontonasal mass often poses a diagnostic challenge to the clinician. The most pressing issue is whether the mass extends intracranially. The development of the frontonasal region or anterior neuropore is complex. Aberrant embryogenesis leads to three main types of anomalies: nasal dermal sinus, anterior cephalocele, and nasal glioma. Understanding the developmental anatomy of the anterior neuropore and postnatal maturation will serve the radiologist well when it comes to imaging frontonasal masses. Pitfalls particularly common to CT imaging interpretation include the evolving ossification of the frontal, nasal and ethmoid bones in the first year of life, morphology and size of the foramen cecum, and the natural intumescence of the anterior nasal septum. Determination of the presence of a connection between the frontonasal mass and the anterior cranial fossae is crucial in the imaging assessment and clinical management. In the case of the nasal dermal sinus, failure to appreciate the intracranial components of the malformation can lead to fatal meningitis. MR imaging is the modality of choice for assessing the pediatric frontonasal region. Its advantages include multiplanar imaging, distinguishing the interface among cartilage, bone, brain and fluid, diffusion imaging to detect epidermoid tumors, and the capacity to evaluate the brain for associated cerebral anomalies. (orig.)

  4. Microstructural investigation of variations in the proof strength of Nimonic PE16

    International Nuclear Information System (INIS)

    Riley, B.F.; Wilson, E.G.; Jones, A.R.

    1987-01-01

    Nimonic PE16 shows a correlation of stress rupture behaviour after irradiation with proof strength. Proof testing of material from bars from several casts yielded a relationship (Hall-Petch) between the peak-aged proof stress and grain size -1/2 but the scatter in proof stress values at a given grain size merited further microstructural study. Transmission electron microscopy revealed that high proof stress material contained dislocation densities consistent with material which had received 1 to 2% cold work, verified by examination of lightly prestrained tensile specimens. Ageing to peak strength induced partial recovery but some variability in proof stress remained. Variations in γ' size and composition having been eliminated, the scatter in proof stress values was attributed to variable cold work induced by the commercial bar straightening process. (Author)

  5. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    Science.gov (United States)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  6. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  7. Magnetic resonance imaging of the shoulder

    International Nuclear Information System (INIS)

    Ilieva, E.

    2015-01-01

    Full text: Magnetic resonance imaging (MRI) is an excellent non-invasive imaging tool that can complement the physical examination in the evaluation of traumatic and non-traumatic injuries of the shoulder. The superb soft tissue contrast and multiplanar capabilities of MRI make it a preferred modality to provide a global assessment of the soft tissue and osseous structures of the shoulder. Learning objectives: to review briefly the anatomy of the shoulder and the specificity of sequences and planes for MRI; to demonstrate the characteristic MR findings of some of the most common shoulder disorders; to indicate how MR arthrography (MRA) of the shoulder can add extra value to the diagnostic process; to outline a systematic approach to the interpretation of the shoulder MR examination. Choosing the most suitable sequences and planes as well as the thorough knowledge of the anatomic structures assist the correct diagnosis of the pathologic disorders of the shoulder which is of great importance for the precise treatment management, surgical versus conservative, as well as for the appropriate surgical approach, open versus arthroscopic

  8. Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT

    International Nuclear Information System (INIS)

    Barras, Heloise; Dunet, Vincent; Hachulla, Anne-Lise; Grimm, Jochen; Beigelman-Aubry, Catherine

    2016-01-01

    Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown. To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition. Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2–3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT. The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts. The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique

  9. Imaging and treatment of a fracture of the hamate bone

    International Nuclear Information System (INIS)

    Andresen, R.; Radmer, S.; Scheufler, O.; Banzer, D.

    2001-01-01

    The relatively rare fractures of the hamate bone are the most common osseous injuries of the distal carpal row, whereby fractures of both the body and the hook of the hamate occur. We present a hamulus ossis hamati fracture that was caused by direct trauma in a high-level game of underwater rugby. Although this was diagnosed by conventional X-ray, the precise position of the fracture was clearly imaged using thin-layer CT, while additional multiplanar MRT revealed further sequelae of the trauma. A CT follow-up after 10 weeks of conservative therapy did not show any osseous consolidation, which indicated the need for surgical revision with exstirpation of the hamulus. (orig.) [de

  10. Organization and visualization of medical images in radiotherapy

    International Nuclear Information System (INIS)

    Lorang, T.

    2001-05-01

    In modern radiotherapy, various imaging equipment is used to acquire views from inside human bodies. Tomographic imaging equipment is acquiring stacks of cross-sectional images, software implementations derive three-dimensional volumes from planar images to allow for visualization of reconstructed cross-sections at any orientation and location and higher-level visualization systems allow for transparent views and surface rendering. Of upcoming interest in radiotherapy is mutual information, the integration of information from multiple imaging equipment res. from the same imaging equipment at different time stamps and varying acquisition parameters. Huge amounts of images are acquired nowadays at radiotherapy centers, requiring organization of images with respect to patient, acquisition and equipment to allow for visualization of images in a comparative and integrative manner. Especially for integration of image information from different equipment, geometrical information is required to allow for registration of images res. volumes. DICOM 3.0 has been introduced as a standard for information interchange with respect to medical imaging. Geometric information of cross-sections, demographic information of patients and medical information of acquisitions and equipment are covered by this standard, allowing for a high-level automation with respect to organization and visualization of medical images. Reconstructing cross-sectional images from volumes at any orientation and location is required for the purpose of registration and multi-planar views. Resampling and addressing of discrete volume data need be implemented efficiently to allow for simultaneous visualization of multiple cross-sectional images, especially with respect to multiple, non-isotropy volume data sets. (author)

  11. A portable virtual machine target for proof-carrying code

    DEFF Research Database (Denmark)

    Franz, Michael; Chandra, Deepak; Gal, Andreas

    2005-01-01

    Virtual Machines (VMs) and Proof-Carrying Code (PCC) are two techniques that have been used independently to provide safety for (mobile) code. Existing virtual machines, such as the Java VM, have several drawbacks: First, the effort required for safety verification is considerable. Second and mor...... simultaneously providing efficient justin-time compilation and target-machine independence. In particular, our approach reduces the complexity of the required proofs, resulting in fewer proof obligations that need to be discharged at the target machine....

  12. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation.

    Science.gov (United States)

    Gonçalves, Luís F; Lee, Wesley; Chaiworapongsa, Tinnakorn; Espinoza, Jimmy; Schoen, Mary Lou; Falkensammer, Peter; Treadwell, Marjorie; Romero, Roberto

    2003-12-01

    This study was undertaken to describe a new technique for the examination of the fetal heart using four-dimensional ultrasonography with spatiotemporal image correlation (STIC). Volume data sets of the fetal heart were acquired with a new cardiac gating technique (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall. These volumes were obtained from 69 fetuses: 35 normal, 16 with congenital anomalies not affecting the cardiovascular system, and 18 with cardiac abnormalities. Dynamic multiplanar slicing and surface rendering of cardiac structures were performed. To illustrate the STIC technique, two representative volumes from a normal fetus were compared with volumes obtained from fetuses with the following congenital heart anomalies: atrioventricular septal defect, tricuspid stenosis, tricuspid atresia, and interrupted inferior vena cava with abnormal venous drainage. Volume datasets obtained with a transverse sweep were utilized to demonstrate the cardiac chambers, moderator band, interatrial and interventricular septae, atrioventricular valves, pulmonary veins, and outflow tracts. With the use of a reference dot to navigate the four-chamber view, intracardiac structures could be simultaneously studied in three orthogonal planes. The same volume dataset was used for surface rendering of the atrioventricular valves. The aortic and ductal arches were best visualized when the original plane of acquisition was sagittal. Volumes could be interactively manipulated to simultaneously visualize both outflow tracts, in addition to the aortic and ductal arches. Novel views of specific structures were generated. For example, the location and extent of a ventricular septal defect was imaged in a sagittal view of the interventricular septum. Furthermore, surface-rendered images of the atrioventricular valves were employed to distinguish between normal and pathologic conditions. Representative video clips were posted on the Journal's Web

  13. Epidemiology, imaging, and treatment of Lisfranc fracture-dislocations revisited

    International Nuclear Information System (INIS)

    Kalia, Vivek; Fishman, Elliot K.; Carrino, John A.; Fayad, Laura M.

    2012-01-01

    The purpose of this article is to discuss the features of Lisfranc injuries and identify their typical imaging findings on radiographs, CT, and MR imaging. Lisfranc injuries are most often caused by hyperplantarflexion of the foot, often during a sporting injury or in high-speed motor vehicle collisions. The most common radiographic findings include diastasis of the base of the first and second metatarsals and the ''fleck'' sign, though neither is necessarily present in every Lisfranc fracture-dislocation. Owing to their often subtle radiographic presentation, clinically suspected Lisfranc injuries warrant imaging with a more sensitive test for the detection of osseous and ligamentous Lisfranc injuries. 3D CT imaging provides a comprehensive evaluation of the injury for optimal treatment planning, with resultant decreased long-term patient morbidity. Furthermore, 3D volume-rendered CT and CT multiplanar reconstructions (MPRs) provide osseous and neurovascular anatomic detail that may be a considerable help with surgical planning for operative cases of Lisfranc injuries. Also, with 3D CT and MPRs, other occult fractures, which are common in patients with high-energy injury and multiple trauma, may become evident. (orig.)

  14. Relativistic particle dynamics: Lagrangian proof of the no-interaction theorem

    International Nuclear Information System (INIS)

    Marmo, G.; Mukunda, N.; Sudarshan, E.C.G.

    1983-11-01

    An economical proof is given, in the Lagrangian framework, of the No Interaction Theorem of relativistic particle mechanics. It is based on the assumption that there is a Lagrangian, which if singular is allowed to lead at most to primary first class constraints. The proof works with Lagrange rather than Poisson brackets, leading to considerable simplifications compared to other proofs

  15. The direct Flow parametric Proof of Gauss' Divergence Theorem revisited

    DEFF Research Database (Denmark)

    Markvorsen, Steen

    The standard proof of the divergence theorem in undergraduate calculus courses covers the theorem for static domains between two graph surfaces. We show that within first year undergraduate curriculum, the flow proof of the dynamic version of the divergence theorem - which is usually considered...... we apply the key instrumental concepts and verify the various steps towards this alternative proof of the divergence theorem....

  16. Three Styles Characterising Mathematicians' Pedagogical Perspectives on Proof

    Science.gov (United States)

    Hemmi, Kirsti

    2010-01-01

    The article describes mathematicians' pedagogical perspectives on proof in the teaching of first year university students at a mathematics department in Sweden. A conceptual frame that was used in the data analysis combines theories about proof from earlier mathematics education research with a social practice approach of Lave and Wenger. A…

  17. Reliability analysis of structures under periodic proof tests in service

    Science.gov (United States)

    Yang, J.-N.

    1976-01-01

    A reliability analysis of structures subjected to random service loads and periodic proof tests treats gust loads and maneuver loads as random processes. Crack initiation, crack propagation, and strength degradation are treated as the fatigue process. The time to fatigue crack initiation and ultimate strength are random variables. Residual strength decreases during crack propagation, so that failure rate increases with time. When a structure fails under periodic proof testing, a new structure is built and proof-tested. The probability of structural failure in service is derived from treatment of all the random variables, strength degradations, service loads, proof tests, and the renewal of failed structures. Some numerical examples are worked out.

  18. Maximum intensity projection MR angiography using shifted image data

    International Nuclear Information System (INIS)

    Machida, Yoshio; Ichinose, Nobuyasu; Hatanaka, Masahiko; Goro, Takehiko; Kitake, Shinichi; Hatta, Junicchi.

    1992-01-01

    The quality of MR angiograms has been significantly improved in past several years. Spatial resolution, however, is not sufficient for clinical use. On the other hand, MR image data can be filled at anywhere using Fourier shift theorem, and the quality of multi-planar reformed image has been reported to be improved remarkably using 'shifted data'. In this paper, we have clarified the efficiency of 'shifted data' for maximum intensity projection MR angiography. Our experimental studies and theoretical consideration showd that the quality of MR angiograms has been significantly improved using 'shifted data' as follows; 1) remarkable reduction of mosaic artifact, 2) improvement of spatial continuity for the blood vessels, and 3) reduction of variance for the signal intensity along the blood vessels. In other words, the angiograms looks much 'finer' than conventional ones, although the spatial resolution is not improved theoretically. Furthermore, we found the quality of MR angiograms dose not improve significantly with the 'shifted data' more than twice as dense as ordinal ones. (author)

  19. 33 CFR 136.233 - Proof.

    Science.gov (United States)

    2010-07-01

    ... SOURCE; AND ADVERTISEMENT Procedures for Particular Claims § 136.233 Proof. In addition to the... must be established. (d) Whether alternative employment or business was available and undertaken and...

  20. Proof Pad: A New Development Environment for ACL2

    Directory of Open Access Journals (Sweden)

    Caleb Eggensperger

    2013-04-01

    Full Text Available Most software development projects rely on Integrated Development Environments (IDEs based on the desktop paradigm, with an interactive, mouse-driven user interface. The standard installation of ACL2, on the other hand, is designed to work closely with Emacs. ACL2 experts, on the whole, like this mode of operation, but students and other new programmers who have learned to program with desktop IDEs often react negatively to the process of adapting to an unfamiliar form of interaction. This paper discusses Proof Pad, a new IDE for ACL2. Proof Pad is not the only attempt to provide ACL2 IDEs catering to students and beginning programmers. The ACL2 Sedan and DrACuLa systems arose from similar motivations. Proof Pad builds on the work of those systems, while also taking into account the unique workflow of the ACL2 theorem proving system. The design of Proof Pad incorporated user feedback from the outset, and that process continued through all stages of development. Feedback took the form of direct observation of users interacting with the IDE as well as questionnaires completed by users of Proof Pad and other ACL2 IDEs. The result is a streamlined interface and fast, responsive system that supports using ACL2 as a programming language and a theorem proving system. Proof Pad also provides a property-based testing environment with random data generation and automated interpretation of properties as ACL2 theorem definitions.

  1. CT of the musculoskeletal system: What is left is the days of MRI?

    International Nuclear Information System (INIS)

    West, A.T.H.; Marshall, T.J.; Bearcroft, P.W.

    2009-01-01

    Magnetic resonance imaging (MRI) plays a central role in the modern imaging of musculoskeletal disorders, due to its ability to produce multiplanar images and characterise soft tissues accurately. However, computed tomography (CT) still has an important role to play, not merely as an alternative to MRI, but as being the preferred imaging investigation in some situations. This article briefly reviews the history of CT technology, the technical factors involved and a number of current applications, as well as looking at future areas where CT may be employed. The advent of ever-increasing numbers of rows of detectors has opened up more possible uses for CT technology. However, diagnostic images may be obtained from CT systems with four rows of detectors or more, and their ability to produce near isotropic voxels and therefore multiplanar reformats. (orig.)

  2. A New Small Emendation of Gödel's Ontological Proof

    Czech Academy of Sciences Publication Activity Database

    Hájek, Petr

    2002-01-01

    Roč. 71, č. 2 (2002), s. 149-164 ISSN 0039-3215 R&D Projects: GA MŠk LN00A056 Keywords : ontological proof * Gödel proof * modal logic * comprehension * positive properties Subject RIV: BA - General Mathematics

  3. Reversal burden of proof on corruption in Indonesia

    Directory of Open Access Journals (Sweden)

    Hibnu Nugroho

    2018-03-01

    Full Text Available Corruption becomes the greatest enemy most countries face including Indonesia. Commitment to eradicate corruption significantly increases yet it would be meaningless if it is not supported by adequate legislation to implement the law effectively. Reversal burden of proof essentially aims to facilitate law enforcers to seek and disclose assets a suspect owns allegedly as corruption crime. The principle of reversal burden of proof was originated from Anglo-Saxon countries and this still applies to certain cases such as bribery-related gratifications as Malaysia and Singapore implement. In Indonesia, provisions on the principle of reversal burden of proof have been long recognized even since 1960 on the first law on corruption crimes. Nevertheless, for more than a half of century, the provision on reversal burden of proof has never been implemented. It occurs since articles which govern the issues barely provide clear regulation. It only mentions the principle yet never issues an implemented regulation to support the principle. In regards to this, the research is aimed at investigating, seeking and analyzing the weaknesses in implementing the principle of reversal burden of proof in corruption crimes recently as well as discussing obstacles in law enforcement.

  4. MR imaging features of the congenital uterine anomalies

    International Nuclear Information System (INIS)

    Hamcan, S.; Akgun, V.; Battal, B.; Kocaoglu, M.

    2012-01-01

    Full text: Introduction: Congenital uterine anomalies are common and usually asymptomatic. The agenesis, malfusion or deficient resorption of the Mullerian canals during embryogenesis may lead to these anomalies. Although ultrasonography (US) is the first step imaging technique in assessment of the uterine pathologies, it can be insufficient in differentiation of them. Magnetic resonance (MR) imaging is an adequate imaging technique in depicting pelvic anatomy and different types of uterine anomalies. Objectives and tasks: In this article, we aimed to present imaging features of the uterine anomalies. Material and methods: Pelvic MR scans of the cases who were referred to our radiology department for suspicious uterine anomaly were evaluated retrospectively. Results: We determined uniconuate uterus (type II), uterus didelphys (type III), bicornuate uterus (type IV), uterine septum (type V) and arcuate uterus (type VI) anomalies according to ASRM (American Society of Reproductive Medicine) classification. Conclusion: In cases with such pathologies leading to obstruction, dysmenorrhea or palpable pelvic mass in the puberty are the main clinical presentations. In cases without obstruction, infertility or multiple abortions can be encountered in reproductive ages. The identification of the subtype of the uterine anomalies is important for the preoperative planning of the management. MR that has multiplanar imaging capability and high soft tissue resolution is a non-invasive and the most important imaging modality for the detection and classification of the uterine anomalies

  5. Proof of the positive energy theorem including the angular momentum contribution

    International Nuclear Information System (INIS)

    Zhang Jingfei; Chee, G.Y.; Guo Yongxin

    2005-01-01

    A proof of the positive energy theorem of general relativity is given. In this proof the gravitational Lagrangian is identified with that of Lau and is equivalent to the teleparallel Lagrangian modulo, a boundary term. The approach adopted in this proof uses the two-spinor method and the extended Witten identities and then combines the Brown-York and the Nester-Witten approaches. At the same time the proof is extended to the case involving the contribution of angular momentum by choosing a special shift vector

  6. MR imaging of congenital heart diseases in adolescents and adults

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Yeon Hyeon; Kang, I Seok; Park, Seung Woo; Lee, Heung Jae [Sungkwunkwan University School of Medicine, Seoul (Korea, Republic of)

    2001-09-01

    Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  7. Diagnosis of dorsal inter osseous pseudotumours by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Peh, W.C.G.; Wong, L.L.S.; Ip, W.Y.

    1999-01-01

    Two middle-aged-patients each presenting with a progressively enlarging mass in the first dorsal web space of their hands are reported. Magnetic resonance imaging (MRI) demonstrated the cause to be a hypertrophic first dorsal inter osseous muscle, with normal T1, T2 and post-gadopentetate dimeglumine signal characteristics. The ability of MRI to diagnose anatomical variants of hand muscles is important in the clinical management of patients with these pseudotumours. The usefulness of magnetic resonance imaging (MRI) in evaluation of soft tissue tumours of the musculoskeletal system is now widely accepted. Its ability to maximize contrast between tumour and adjacent normal tissue in a multiplanar manner makes it the imaging modality of choice in pre-operative staging of soft tissue masses. In the hand and wrist, where benign tumours predominate, MRI may provide a specific diagnosis. We describe two cases in which MRI demonstrated the cause of a hand pseudotumour to be due to hypertrophy of the first dorsal inter osseous muscle. Copyright (1999) Blackwell Science Pty Ltd

  8. Diagnosis of dorsal inter osseous pseudotumours by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Peh, W.C.G.; Wong, L.L.S. [The University of Hong Kong, Queen Mary Hospital, (Hong Kong). Hand Surgery Division, Department of Diagnotic Radiology; Ip, W.Y. [The University of Hong Kong, Queen Mary Hospital, (Hong Kong). Hand Surgery Division, Department of Orthopaedic Surgery

    1999-08-01

    Two middle-aged-patients each presenting with a progressively enlarging mass in the first dorsal web space of their hands are reported. Magnetic resonance imaging (MRI) demonstrated the cause to be a hypertrophic first dorsal inter osseous muscle, with normal T1, T2 and post-gadopentetate dimeglumine signal characteristics. The ability of MRI to diagnose anatomical variants of hand muscles is important in the clinical management of patients with these pseudotumours. The usefulness of magnetic resonance imaging (MRI) in evaluation of soft tissue tumours of the musculoskeletal system is now widely accepted. Its ability to maximize contrast between tumour and adjacent normal tissue in a multiplanar manner makes it the imaging modality of choice in pre-operative staging of soft tissue masses. In the hand and wrist, where benign tumours predominate, MRI may provide a specific diagnosis. We describe two cases in which MRI demonstrated the cause of a hand pseudotumour to be due to hypertrophy of the first dorsal inter osseous muscle. Copyright (1999) Blackwell Science Pty Ltd 20 refs., 3 figs.

  9. Usefulness of biological fingerprint in magnetic resonance imaging for patient verification.

    Science.gov (United States)

    Ueda, Yasuyuki; Morishita, Junji; Kudomi, Shohei; Ueda, Katsuhiko

    2016-09-01

    The purpose of our study is to investigate the feasibility of automated patient verification using multi-planar reconstruction (MPR) images generated from three-dimensional magnetic resonance (MR) imaging of the brain. Several anatomy-related MPR images generated from three-dimensional fast scout scan of each MR examination were used as biological fingerprint images in this study. The database of this study consisted of 730 temporal pairs of MR examination of the brain. We calculated the correlation value between current and prior biological fingerprint images of the same patient and also all combinations of two images for different patients to evaluate the effectiveness of our method for patient verification. The best performance of our system were as follows: a half-total error rate of 1.59 % with a false acceptance rate of 0.023 % and a false rejection rate of 3.15 %, an equal error rate of 1.37 %, and a rank-one identification rate of 98.6 %. Our method makes it possible to verify the identity of the patient using only some existing medical images without the addition of incidental equipment. Also, our method will contribute to patient misidentification error management caused by human errors.

  10. ORION - Crew Module Side Hatch: Proof Pressure Test Anomaly Investigation

    Science.gov (United States)

    Evernden, Brent A.; Guzman, Oscar J.

    2018-01-01

    The Orion Multi-Purpose Crew Vehicle program was performing a proof pressure test on an engineering development unit (EDU) of the Orion Crew Module Side Hatch (CMSH) assembly. The purpose of the proof test was to demonstrate structural capability, with margin, at 1.5 times the maximum design pressure, before integrating the CMSH to the Orion Crew Module structural test article for subsequent pressure testing. The pressure test was performed at lower pressures of 3 psig, 10 psig and 15.75 psig with no apparent abnormal behavior or leaking. During pressurization to proof pressure of 23.32 psig, a loud 'pop' was heard at 21.3 psig. Upon review into the test cell, it was noted that the hatch had prematurely separated from the proof test fixture, thus immediately ending the test. The proof pressure test was expected be a simple verification but has since evolved into a significant joint failure investigation from both Lockheed Martin and NASA.

  11. MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A.; Mueller-Lisse, U.G.; Massmann, J.

    2003-01-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [de

  12. Car sequencing is NP-hard: a short proof

    OpenAIRE

    B Estellon; F Gardi

    2013-01-01

    In this note, a new proof is given that the car sequencing (CS) problem is NP-hard. Established from the Hamiltonian Path problem, the reduction is direct while closing some gaps remaining in the previous NP-hardness results. Since CS is studied in many operational research courses, this result and its proof are particularly interesting for teaching purposes.

  13. A new proof of the positive energy theorem

    International Nuclear Information System (INIS)

    Witten, E.

    1981-01-01

    A new proof is given of the positive energy theorem of classical general relativity. Also, a new proof is given that there are no asymptotically Euclidean gravitational instantons. (These theorems have been proved previously, by a different method, by Schoen and Yau). The relevance of these results to the stability of Minkowski space is discussed. (orig.)

  14. A proof challenge: multiple alignment and information compression

    OpenAIRE

    Wolff, J Gerard

    2014-01-01

    These notes pose a "proof challenge": a proof, or disproof, of the proposition that "For any given body of information, I, expressed as a one-dimensional sequence of atomic symbols, a multiple alignment concept, described in the document, provides a means of encoding all the redundancy that may exist in I. Aspects of the challenge are described.

  15. Noninvasive Differentiation between Hepatic Steatosis and Steatohepatitis with MR Imaging Enhanced with USPIOs in Patients with Nonalcoholic Fatty Liver Disease: A Proof-of-Concept Study.

    Science.gov (United States)

    Smits, Loek P; Coolen, Bram F; Panno, Maria D; Runge, Jurgen H; Nijhof, Wouter H; Verheij, Joanne; Nieuwdorp, Max; Stoker, Jaap; Beuers, Ulrich H; Nederveen, Aart J; Stroes, Erik S

    2016-03-01

    To (a) study the optimal timing and dosing for ultrasmall superparamagnetic iron oxide particle (USPIO)-enhanced magnetic resonance (MR) imaging of the liver in nonalcoholic fatty liver disease, (b) evaluate whether hepatic USPIO uptake is decreased in nonalcoholic steatohepatitis (NASH), and (c) study the diagnostic accuracy of USPIO-enhanced MR imaging to distinguish between NASH and simple steatosis. This prospective study was approved by the local institutional review board, and informed consent was obtained from all patients. Quantitative R2* MR imaging of the liver was performed at baseline and 72 hours after USPIO administration in patients with biopsy-proven NASH (n = 13), hepatic steatosis without NASH (n = 11), and healthy control subjects (n = 9). The hepatic USPIO uptake in the liver was quantified by the difference in R2* (ΔR2*) between the contrast material-enhanced images and baseline images. Between-group differences in mean ΔR2* were tested with the Student t test, and diagnostic accuracy was tested by calculating the area under the receiver operating characteristic curve. Patients with NASH had a significantly lower ΔR2* 72 hours after USPIO administration when compared with patients who had simple steatosis and healthy control subjects (mean ± standard deviation for patients with NASH, 37.0 sec(-1) ± 16.1; patients with simple steatosis, 61.0 sec(-1) ± 17.3; and healthy control subjects, 72.2 sec(-1) ± 22.0; P = .006 for NASH vs simple steatosis; P steatosis was 0.87 (95% confidence interval: 0.72, 1.00). This proof-of-concept study provides clues that hepatic USPIO uptake in patients with NASH is decreased and that USPIO MR imaging can be used to differentiate NASH from simple steatosis.

  16. A Current Review of the Meniscus Imaging: Proposition of a Useful Tool for Its Radiologic Analysis

    Directory of Open Access Journals (Sweden)

    Nicolas Lefevre

    2016-01-01

    Full Text Available The main objective of this review was to present a synthesis of the current literature in order to provide a useful tool to clinician in radiologic analysis of the meniscus. All anatomical descriptions were clearly illustrated by MRI, arthroscopy, and/or drawings. The value of standard radiography is extremely limited for the assessment of meniscal injuries but may be indicated to obtain a differential diagnosis such as osteoarthritis. Ultrasound is rarely used as a diagnostic tool for meniscal pathologies and its accuracy is operator-dependent. CT arthrography with multiplanar reconstructions can detect meniscus tears that are not visible on MRI. This technique is also useful in case of MRI contraindications, in postoperative assessment of meniscal sutures and the condition of cartilage covering the articular surfaces. MRI is the most accurate and less invasive method for diagnosing meniscal lesions. MRI allows confirming and characterizing the meniscal lesion, the type, the extension, its association with a cyst, the meniscal extrusion, and assessing cartilage and subchondral bone. New 3D-MRI in three dimensions with isotropic resolution allows the creation of multiplanar reformatted images to obtain from an acquisition in one sectional plane reconstructions in other spatial planes. 3D MRI should further improve the diagnosis of meniscal tears.

  17. A Current Review of the Meniscus Imaging: Proposition of a Useful Tool for Its Radiologic Analysis

    Science.gov (United States)

    Lefevre, Nicolas; Naouri, Jean Francois; Herman, Serge; Gerometta, Antoine; Klouche, Shahnaz; Bohu, Yoann

    2016-01-01

    The main objective of this review was to present a synthesis of the current literature in order to provide a useful tool to clinician in radiologic analysis of the meniscus. All anatomical descriptions were clearly illustrated by MRI, arthroscopy, and/or drawings. The value of standard radiography is extremely limited for the assessment of meniscal injuries but may be indicated to obtain a differential diagnosis such as osteoarthritis. Ultrasound is rarely used as a diagnostic tool for meniscal pathologies and its accuracy is operator-dependent. CT arthrography with multiplanar reconstructions can detect meniscus tears that are not visible on MRI. This technique is also useful in case of MRI contraindications, in postoperative assessment of meniscal sutures and the condition of cartilage covering the articular surfaces. MRI is the most accurate and less invasive method for diagnosing meniscal lesions. MRI allows confirming and characterizing the meniscal lesion, the type, the extension, its association with a cyst, the meniscal extrusion, and assessing cartilage and subchondral bone. New 3D-MRI in three dimensions with isotropic resolution allows the creation of multiplanar reformatted images to obtain from an acquisition in one sectional plane reconstructions in other spatial planes. 3D MRI should further improve the diagnosis of meniscal tears. PMID:27057352

  18. 29 CFR 1919.73 - Unit proof test and examination of derricks.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of derricks. 1919.73 Section 1919.73 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Devices § 1919.73 Unit proof test and examination of derricks. (a) Unit proof tests of derricks shall be...

  19. Future-proofing nursing education.

    Science.gov (United States)

    Keighley, Tom

    2014-12-01

    The origin of future-proofing seems lost in the mists of recent history. Dictionaries date its use from about 1991, referring to the prevention of obsolescence in information technology manufacturing and occasionally in organizational systems. However, closer analysis in healthcare demonstrates it can be traced back to the Rand Corporation and the studies commissioned there in the 1960s. These aimed at identifying the predictive factors in planning healthcare, including development of the workforce. It is a managerial concept that helps to project a vision of change that is not simply reactive or short-term. It permits a focus on leadership and the maximising of learning opportunities and includes analysis of the policy horizon. It held within it an assumption about the importance of establishing the cognitive frameworks that would influence long-term behaviours and not focus simply on short-term gains. This paper utilises this approach to explore options for future-proofing of nurse education.

  20. Proofs from THE BOOK

    CERN Document Server

    Aigner, Martin

    2014-01-01

    This revised and enlarged fifth edition features four new chapters, which contain highly original and delightful proofs for classics such as the spectral theorem from linear algebra, some more recent jewels like the non-existence of the Borromean rings and other surprises. From the Reviews "... Inside PFTB (Proofs from The Book) is indeed a glimpse of mathematical heaven, where clever insights and beautiful ideas combine in astonishing and glorious ways. There is vast wealth within its pages, one gem after another. ... Aigner and Ziegler... write: "... all we offer is the examples that we have selected, hoping that our readers will share our enthusiasm about brilliant ideas, clever insights and wonderful observations." I do. ... " Notices of the AMS, August 1999 "... This book is a pleasure to hold and to look at: ample margins, nice photos, instructive pictures, and beautiful drawings ... It is a pleasure to read as well: the style is clear and entertaining, the level is close to elementary, the necessary b...

  1. Towards a climate-proof Netherlands. Summary routeplanner

    International Nuclear Information System (INIS)

    Van Drunen, M.

    2007-03-01

    There is no doubt about it: the climate is changing and the effects are now tangible and predictable. Scientific research has shown that even if we make significant reductions in greenhouse gas emissions (mitigation), climate change cannot be prevented. Which is why we have to adapt to make the effects of the changing climate acceptable: the Netherlands must be made climate-proof. To stimulate climate-proofing, four ministries and the Climate changes Spatial Planning (CcSP), Living with Water (LmW) and Habiforum research programmes have established a National Programme on Adapting Spatial Planning to Climate Change (ARK). The core research questions examined by ARK are: What is the nature and scale of the observable and expected impacts of climate change for various themes and economic sectors?; What spatial issues do they raise?; How can we tackle these spatial issues?; What dilemmas (technical, administrative, economic, social) will we face when trying to resolve these issues? The Routeplanner is the scientific arm of ARK: the three research programmes, assisted by other research institutes, supply ARK with scientific information and insights on climate-proofing the spatial development of the Netherlands. This brochure summarises the outcome of phase 2 of Routeplanner, which took place in 2006. It consisted of a Climate-proofing Baseline Assessment, a review (Quickscan) of knowledge gaps, formulation of adaptation strategies, a qualitative assessment of adaptation options, a quantitative assessment of adaptation options and identification of case studies. This brochure answers the following questions, as far as current scientific understanding permits: How will climate change affect the Netherlands?; What are the consequences of climate change for the Netherlands?; What must be done?; When must we act?; What examples are there of climate-proof strategies?; What next? The main conclusion of the Routeplanner is that climate change can cause considerable damage in

  2. Evaluation of predator-proof fenced biodiversity projects

    OpenAIRE

    Doelle, Sebastian

    2012-01-01

    There has been recent debate over the role of predator-proof fences in the management of New Zealand’s biodiversity. The debate has arisen due to concern that investments in fenced sanctuaries are less productive than are alternative ways to manage biodiversity. Predator-proof fences are costly and budget constraints limit the area of habitat that can be fenced. The area of habitat enclosed within fences, and number of individuals of species supported, determines project’s ability to contribu...

  3. Reconstruction CT imaging of the hypopharynx and the larynx

    International Nuclear Information System (INIS)

    Okuno, Tetsuji; Fujimura, Akiko; Murakami, Yasushi; Shiga, Hayao

    1986-01-01

    The multiplanar reconstruction CT imaging of the hypopharynx and the larynx was performed on a total of 20 cases: 8 with laryngeal carcinomas, 6 with hypopharyngeal carcinomas, 4 with vocal cord paralyses due to various causes, 1 with laryngeal amyloidosis, 1 with inflammatory granuloma of the hypopharynx. Coronal, segittal, and parasagittal reconstruction images were obtained from either 1 or 2 mm overlapping axial scans with 4 or 5 mm slice thickness (3 cases) using 5 sec scan times during queit breathing. In 15 cases with coronal reconstruction imaging, the anatomical derangements of the laryngopharyngeal structures especially along the undersurface of the true vocal cord to the false cord level, the lateral wall of the pyriform sinus, and the paraglottic space were demonstrated more clearly than the axial CT imaging. In 5 cases with sagittal reconstruction imaging, the vertical extension of the lesions through the anterior commisure was more clearly depicted than the axial CT imaging. In 8 cases with parasagittal reconstruction imaging, which is along the vocal fold or across the aryepiglottic fold, pathological changes along the aryepiglottic fold, the arytenoid-corniculate cartilage complex, and the tip of the pyriform sinus were more clearly demonstrated than the axial CT imaging. In determining the feasibility of conservation surgery of the larynx and the hypopharynx, reconstruction CT imaging is recommended as the diagnostic procedure of a choice, which would supplement the findings of the routine axial CT imaging. (author)

  4. Dynamic PROOF clusters with PoD: architecture and user experience

    Science.gov (United States)

    Manafov, Anar

    2011-12-01

    PROOF on Demand (PoD) is a tool-set, which sets up a PROOF cluster on any resource management system. PoD is a user oriented product with an easy to use GUI and a command-line interface. It is fully automated. No administrative privileges or special knowledge is required to use it. PoD utilizes a plug-in system, to use different job submission front-ends. The current PoD distribution is shipped with LSF, Torque (PBS), Grid Engine, Condor, gLite, and SSH plug-ins. The product is to be extended. We therefore plan to implement a plug-in for AliEn Grid as well. Recently developed algorithms made it possible to efficiently maintain two types of connections: packet-forwarding and native PROOF connections. This helps to properly handle most kinds of workers, with and without firewalls. PoD maintains the PROOF environment automatically and, for example, prevents resource misusage in case when workers idle for too long. As PoD matures as a product and provides more plug-ins, it's used as a standard for setting up dynamic PROOF clusters in many different institutions. The GSI Analysis Facility (GSIAF) is in production since 2007. The static PROOF cluster has been phased out end of 2009. GSIAF is now completely based on PoD. Users create private dynamic PROOF clusters on the general purpose batch farm. This provides an easier resource sharing between interactive local batch and Grid usage. The main user communities are FAIR and ALICE.

  5. First Human Use of a Radiopharmaceutical Prepared by Continuous-Flow Microfluidic Radiofluorination: Proof of Concept with the Tau Imaging Agent [18F]T807

    Directory of Open Access Journals (Sweden)

    Steven H. Liang

    2014-10-01

    Full Text Available Despite extensive preclinical imaging with radiotracers developed by continuous-flow microfluidics, a positron emission tomographic (PET radiopharmaceutical has not been reported for human imaging studies by this technology. The goal of this study was to validate the synthesis of the tau radiopharmaceutical 7-(6-fluoropyridin-3-yl-5H-pyrido[4,3-b]indole ([18F]T807 and perform first-in-human PET scanning enabled by microfluidic flow chemistry. [18F]T807 was synthesized by our modified one-step method and adapted to suit a commercial microfluidic flow chemistry module. For this proof of concept, the flow system was integrated to a GE Tracerlab FXFN unit for high-performance liquid chromatography purification and formulation. Three consecutive productions of [18F]T807 were conducted to validate this radiopharmaceutical. Uncorrected radiochemical yields of 17 ± 1% of crude [18F]T807 (≈ 500 mCi, radiochemical purity 95% were obtained from the microfluidic device. The crude material was then purified, and > 100 mCi of the final product was obtained in an overall uncorrected radiochemical yield of 5 ± 1% (n = 3, relative to starting [18F]fluoride (end of bombardment, with high radiochemical purity (≥ 99% and high specific activities (6 Ci/μmol in 100 minutes. A clinical research study was carried out with [18F]T807, representing the first reported human imaging study with a radiopharmaceutical prepared by this technology.

  6. Completing the proof of “Generic quantum nonlocality”

    Energy Technology Data Exchange (ETDEWEB)

    Gachechiladze, Mariami; Gühne, Otfried, E-mail: otfried.guehne@uni-siegen.de

    2017-04-18

    In a paper by Popescu and Rohrlich a proof has been presented showing that any pure entangled multiparticle quantum state violates some Bell inequality. We point out a gap in this proof, but we also give a construction to close this gap. It turns out that with some extra effort all the results from the aforementioned publication can be proven. Our construction shows how two-particle entanglement can be generated via performing local projections on a multiparticle state. - Highlights: • A proof is completed, showing that any pure entangled multiparticle quantum state violates some Bell inequality. • The results demonstrate how an multi-qubit state can be transformed by local measurements to a two-qubit entangled state. • The extension to higher dimensions is discussed.

  7. Completing the proof of “Generic quantum nonlocality”

    International Nuclear Information System (INIS)

    Gachechiladze, Mariami; Gühne, Otfried

    2017-01-01

    In a paper by Popescu and Rohrlich a proof has been presented showing that any pure entangled multiparticle quantum state violates some Bell inequality. We point out a gap in this proof, but we also give a construction to close this gap. It turns out that with some extra effort all the results from the aforementioned publication can be proven. Our construction shows how two-particle entanglement can be generated via performing local projections on a multiparticle state. - Highlights: • A proof is completed, showing that any pure entangled multiparticle quantum state violates some Bell inequality. • The results demonstrate how an multi-qubit state can be transformed by local measurements to a two-qubit entangled state. • The extension to higher dimensions is discussed.

  8. Towards Verification of Constituent Systems through Automated Proof

    DEFF Research Database (Denmark)

    Couto, Luis Diogo Monteiro Duarte; Foster, Simon; Payne, R

    2014-01-01

    This paper explores verification of constituent systems within the context of the Symphony tool platform for Systems of Systems (SoS). Our SoS modelling language, CML, supports various contractual specification elements, such as state invariants and operation preconditions, which can be used...... to specify contractual obligations on the constituent systems of a SoS. To support verification of these obligations we have developed a proof obligation generator and theorem prover plugin for Symphony. The latter uses the Isabelle/HOL theorem prover to automatically discharge the proof obligations arising...... from a CML model. Our hope is that the resulting proofs can then be used to formally verify the conformance of each constituent system, which is turn would result in a dependable SoS....

  9. Preservice Mathematics Teachers' Metaphorical Perceptions towards Proof and Proving

    Science.gov (United States)

    Ersen, Zeynep Bahar

    2016-01-01

    Since mathematical proof and proving are in the center of mathematics; preservice mathematics teachers' perceptions against these concepts have a great importance. Therefore, the study aimed to determine preservice mathematics teachers' perceptions towards proof and proving through metaphors. The participants consisted of 192 preservice…

  10. Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT

    International Nuclear Information System (INIS)

    Kotsianos, D.; Rock, C.; Wirth, S.; Linsenmaier, U.; Brandl, R.; Fischer, T.; Pfeifer, K.J.; Reiser, M.; Euler, E.; Mutschler, W.

    2002-01-01

    Purpose: To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Method: Human knee specimens (n=22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Mueller AO classification. To confirm the results, the specimens were finally surgically dissected. Results: 97% of the tibial condylar fractures were easily seen and correctly classified according to the Mueller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. (orig.) [de

  11. A short proof of increased parabolic regularity

    Directory of Open Access Journals (Sweden)

    Stephen Pankavich

    2015-08-01

    Full Text Available We present a short proof of the increased regularity obtained by solutions to uniformly parabolic partial differential equations. Though this setting is fairly introductory, our new method of proof, which uses a priori estimates and an inductive method, can be extended to prove analogous results for problems with time-dependent coefficients, advection-diffusion or reaction diffusion equations, and nonlinear PDEs even when other tools, such as semigroup methods or the use of explicit fundamental solutions, are unavailable.

  12. Bribe-proof Rules in the Division Problem

    OpenAIRE

    Jordi MassóAuthor-Email:; Alejandro Neme

    2003-01-01

    The division problem consists of allocating an amount of a perfectly divisible good among a group of n agents with single-peaked preferences. A rule maps preference profiles into n shares of the amount to be allocated. A rule is bribe-proof if no group of agents can compensate another agent to misrepresent his preference and, after an appropriate redistribution of their shares, each obtain a strictly preferred share. We characterize all bribe-proof rules as the class of efficient, strategy-pr...

  13. 29 CFR 1919.71 - Unit proof test and examination of cranes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...

  14. Burden of Proof in Bioethics.

    Science.gov (United States)

    Koplin, Julian J; Selgelid, Michael J

    2015-11-01

    A common strategy in bioethics is to posit a prima facie case in favour of one policy, and to then claim that the burden of proof (that this policy should be rejected) falls on those with opposing views. If the burden of proof is not met, it is claimed, then the policy in question should be accepted. This article illustrates, and critically evaluates, examples of this strategy in debates about the sale of organs by living donors, human enhancement, and the precautionary principle. We highlight general problems with this style of argument, and particular problems with its use in specific cases. We conclude that the burden ultimately falls on decision-makers (i.e. policy-makers) to choose the policy supported by the best reasons. © 2015 John Wiley & Sons Ltd.

  15. MR imaging of peripheral nervous system involvement: Parsonage-Turner syndrome.

    Science.gov (United States)

    Zara, Gabriella; Gasparotti, Roberto; Manara, Renzo

    2012-04-15

    A 55-year-old woman complained of right scapular pain, like burning, radiating down his right arm and numbness in the first three fingers of the hand. Neurologic examination showed a slight deficit of the right brachial triceps muscle. Neurophysiological assessment showed a mild involvement of the seventh right spinal root (C7). Conventional MR imaging of the cervical spine showed mild disc protrusion at level C5-C6 without spinal root compression. High resolution MR neurography with multiplanar reconstruction along the course of the right brachial plexus showed a mild increase in signal intensity and thickening of the C7 root, middle trunk and posterior cord, consistent with Parsonage-Turner Syndrome. STIR images showed increased signal intensity in the right infraspinatus muscle innervated by the suprascapular nerve. In our case, sensitivity and specificity of the new MR sequences are higher than the clinical and neurophysiological evaluations. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. The direct Flow parametric Proof of Gauss' Divergence Theorem revisited

    OpenAIRE

    Markvorsen, Steen

    2006-01-01

    The standard proof of the divergence theorem in undergraduate calculus courses covers the theorem for static domains between two graph surfaces. We show that within first year undergraduate curriculum, the flow proof of the dynamic version of the divergence theorem - which is usually considered only much later in more advanced math courses - is comprehensible with only a little extension of the first year curriculum. Moreover, it is more intuitive than the static proof. We support this intuit...

  17. A compositional proof system for the modal μ-calculus

    DEFF Research Database (Denmark)

    Andersen, Henrik Reif; Stirling, C.; Winskel,, G.

    1994-01-01

    We present a proof system for determining satisfaction between processes in a fairly general process algebra and assertions of the modal μ-calculus. The proof system is compositional in the structure of processes. It extends earlier work on compositional reasoning within the modal μ-calculus and ...

  18. Nonglobal proof of the thin--sandwich conjecture

    International Nuclear Information System (INIS)

    Pereira, C.M.

    1981-01-01

    A gravitational thin--sandwich conjecture was first proposed by Wheeler and coworkers during the period 1962--4. The present paper contains a proof of the nonglobal form of this gravitational thin--sandwich conjecture. The proof (a) applies for arbitrary choices of the spatial metric and its time derivative; and (b) demonstrates the existence on a spacelike three-surface of solutions which satisfy conditions of continuity known to be sufficient to obtain existence and uniqueness of solutions to Einstein's equations off the three-surface and existence and uniqueness of geodesics. Riquier's existence theorem plays an important role in the proof. The relationship of the present results to previous work is discussed. Some global questions associated with the thin--sandwich conjecture are clarified. Some aspects of the relationship of the thin--sandwich conjecture to the problem of the quantization of the gravitational field are noted. Both the vacuum case and the case of a nonviscous fluid are included. The discussion allows for an arbitrary equation of state p = p

  19. CT and MR imaging of primary tumors of the masticator space

    International Nuclear Information System (INIS)

    Aspestrand, F.; Boysen, M.

    1992-01-01

    A retrospective study of CT and MR examinations in 14 patients with benign and malignant tumors originating in the masticator space is presented. At presentation, 12 patients revealed tumor extension to adjacent regions and spaces. Perineutral tumor spread along trigeminal nerve branches to the cavernous sinus and orbits was combined with facial pain, and/or numbness, ophthalmoplegia, and exophthalmus. Detailed analysis of tumor growth and spread, enhancement and signal features at CT and MR imaging indicated that tumor histology was, with a few exceptions, nonspecific. More extensive growth and bone destruction was noted only among malignant tumors. MR imaging was found superior to CT in delineating tumor extension due to better soft tissue contrast resolution and multiplanar imaging. Posttreatment examinations were available in 11 patients and showed long-standing regional edema of the adjacent temporal lobe and masticator muscles in 4 out of 5 patients without clinical evidence of tumor. In 6 patients, CT and MR features were found almost unchanged with only small size differences after various forms of treatment. (orig.)

  20. On the Mechanization of the Proof of Hessenberg's Theorem in Coherent Logic

    NARCIS (Netherlands)

    Bezem, M.; Hendriks, R.D.A.

    2008-01-01

    We propose to combine interactive proof construction with proof automation for a fragment of first-order logic called Coherent Logic (CL). CL allows enough existential quantification to make Skolemization unnecessary. Moreover, CL has a constructive proof system based on forward reasoning, which is

  1. Post-therapeutic imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Pollice, Saverio, E-mail: saveriopollice@hotmail.it [Department of Radiology and Neuroradiology, “L. Bonomo Hospital”, 76123 Andria, BT (Italy); Muto, Mario, E-mail: mutomar@tiscali.it [Department of Neuroradiology, “Cardarelli Hospital”, Naples (Italy); Scarabino, Tommaso, E-mail: tscarabino@hotmail.com [Department of Radiology and Neuroradiology, “L. Bonomo Hospital”, 76123 Andria, BT (Italy)

    2015-05-15

    Highlights: • This study is the result of collaboration between neuroradiologists and neurosurgeons. • Comparison between neuroimaging techniques to better evaluate the complications after treatment of the spin. • Evaluation of the imaging features of complications and definition of follow-up. - Abstract: Any surgical approach modifies the normal anatomical and functional arrangement of the segmental spine which is aimed, therefore image interpretation cannot ignore a correct set of knowledge in the field of anatomy, pathophysiology, drug compliance, interventional radiology and surgery. Neuroradiological imaging has an important role before surgery to direct the surgeon or interventional radiologist during the operation, both in post-surgery, where imaging examination can rightly evaluate properties and effects of the treatment and can detect potential complications as infections, abscess, bleeding, exuberant scar, mobilization and rupture of devices. The available methods of imaging are the X-rays (XR) made at least in two projections, Computed Tomography (CT) with MPR (multiplanar) and VR (volume rendering) reconstruction, and Magnetic Resonance (MR), often performed before and after contrast media injection. Imaging assessment of spine after surgery is complex and depends upon several factors, including surgical procedures and disease for which it was performed; biomechanical of the underlying cortical and cancellous bone findings; conditions of muscles, intervertebral disk and ligaments; time since surgery procedures; duration and nature of the post-surgical syndrome. Depending upon several factors, one or a combination of complementary imaging modalities (X-rays, Computed Tomography, Magnetic Resonance) may be required to evaluate effectiveness of the treatment; to demonstrate any clinically relevant abnormality at the treated region and adjacent structures (complications such as inflammation, abscesses, bleeding and misplacement of the device); to

  2. Post-therapeutic imaging findings

    International Nuclear Information System (INIS)

    Pollice, Saverio; Muto, Mario; Scarabino, Tommaso

    2015-01-01

    Highlights: • This study is the result of collaboration between neuroradiologists and neurosurgeons. • Comparison between neuroimaging techniques to better evaluate the complications after treatment of the spin. • Evaluation of the imaging features of complications and definition of follow-up. - Abstract: Any surgical approach modifies the normal anatomical and functional arrangement of the segmental spine which is aimed, therefore image interpretation cannot ignore a correct set of knowledge in the field of anatomy, pathophysiology, drug compliance, interventional radiology and surgery. Neuroradiological imaging has an important role before surgery to direct the surgeon or interventional radiologist during the operation, both in post-surgery, where imaging examination can rightly evaluate properties and effects of the treatment and can detect potential complications as infections, abscess, bleeding, exuberant scar, mobilization and rupture of devices. The available methods of imaging are the X-rays (XR) made at least in two projections, Computed Tomography (CT) with MPR (multiplanar) and VR (volume rendering) reconstruction, and Magnetic Resonance (MR), often performed before and after contrast media injection. Imaging assessment of spine after surgery is complex and depends upon several factors, including surgical procedures and disease for which it was performed; biomechanical of the underlying cortical and cancellous bone findings; conditions of muscles, intervertebral disk and ligaments; time since surgery procedures; duration and nature of the post-surgical syndrome. Depending upon several factors, one or a combination of complementary imaging modalities (X-rays, Computed Tomography, Magnetic Resonance) may be required to evaluate effectiveness of the treatment; to demonstrate any clinically relevant abnormality at the treated region and adjacent structures (complications such as inflammation, abscesses, bleeding and misplacement of the device); to

  3. Values and Norms of Proof for Mathematicians and Students

    Science.gov (United States)

    Dawkins, Paul Christian; Weber, Keith

    2017-01-01

    In this theoretical paper, we present a framework for conceptualizing proof in terms of mathematical values, as well as the norms that uphold those values. In particular, proofs adhere to the values of establishing a priori truth, employing decontextualized reasoning, increasing mathematical understanding, and maintaining consistent standards for…

  4. Security proof for round robin differential phase shift QKD

    NARCIS (Netherlands)

    Leermakers, D.; Skoric, B.

    2017-01-01

    We give the first information-theoretic security proof of the `Round Robin Differential Phase Shift' Quantum Key Distribution scheme. Our proof consists of the following steps. We construct an EPR variant of the scheme. We identify Eve's optimal way of coupling an ancilla to an EPR qudit pair under

  5. Evaluation of Rib Fractures on a Single-in-plane Image Reformation of the Rib Cage in CT Examinations.

    Science.gov (United States)

    Dankerl, Peter; Seuss, Hannes; Ellmann, Stephan; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2017-02-01

    This study aimed to evaluate the diagnostic performance of using a reformatted single-in-plane image reformation of the rib cage for the detection of rib fractures in computed tomography (CT) examinations, employing different levels of radiological experience. We retrospectively evaluated 10 consecutive patients with and 10 patients without rib fractures, whose CT scans were reformatted to a single-in-plane image reformation of the rib cage. Eight readers (two radiologists, two residents in radiology, and four interns) independently evaluated the images for the presence of rib fractures using a reformatted single-in-plane image and a multi-planar image reformation. The time limit was 30 seconds for each read. A consensus of two radiologist readings was considered as the reference standard. Diagnostic performance (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) was assessed and evaluated per rib and per location (anterior, lateral, posterior). To determine the time limit, we prospectively analyzed the average time it took radiologists to assess the rib cage, in a bone window setting, in 50 routine CT examinations. McNemar test was used to compare the diagnostic performances. Single image reformation was successful in all 20 patients. The sensitivity, specificity, PPV, and NPV for the detection of rib fractures using the conventional multi-planar read were 77.5%, 99.2%, 89.9%, and 98.0% for radiologists; 46.3%, 99.7%, 92.5%, and 95.3% for residents; and 29.4%, 99.4%, 82.5%, and 93.9% for interns, respectively. Sensitivity, PPV, and NPV increased across all three groups of experience, using the reformatted single-in-plane image of the rib cage (radiologists: 85.0%, 98.6%, and 98.7%; residents: 80.0%, 92.8%, and 98.2%; interns: 66.9%, 89.9%, and 97.1%), whereas specificity did not change significantly (99.9%, 99.4%, and 99.3%). The diagnostic performance of the interns and residents was significantly better when

  6. 28 CFR 79.25 - Proof of onset of leukemia at least two years after first exposure, and proof of onset of a...

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Proof of onset of leukemia at least two... leukemia at least two years after first exposure, and proof of onset of a specified compensable disease more than five years after first exposure. The date of onset will be the date of diagnosis as indicated...

  7. Imaging the cranial nerves: Part I: Methodology, infectious and inflammatory, traumatic and congenital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Instituto Portugues de Oncologia Francisco Gentil- Centro de Lisboa, Department of Radiology, Lisboa Codex (Portugal); Casselman, Jan [A.Z. St. Jan Brugge Hospital, Department of Radiology, Brugge (Belgium); A.Z. St. Augustinus Antwerpen Hospitals, Department of Radiology, Antwerpen (Belgium)

    2007-08-15

    Many disease processes manifest either primarily or secondarily by cranial nerve deficits. Neurologists, ENT surgeons, ophthalmologists and maxillo-facial surgeons are often confronted with patients with symptoms and signs of cranial nerve dysfunction. Seeking the cause of this dysfunction is a common indication for imaging. In recent decades we have witnessed an unprecedented improvement in imaging techniques, allowing direct visualization of increasingly small anatomic structures. The emergence of volumetric CT scanners, higher field MR scanners in clinical practice and higher resolution MR sequences has made a tremendous contribution to the development of cranial nerve imaging. The use of surface coils and parallel imaging allows sub-millimetric visualization of nerve branches and volumetric 3D imaging. Both with CT and MR, multiplanar and curved reconstructions can follow the entire course of a cranial nerve or branch, improving tremendously our diagnostic yield of neural pathology. This review article will focus on the contribution of current imaging techniques in the depiction of normal anatomy and on infectious and inflammatory, traumatic and congenital pathology affecting the cranial nerves. A detailed discussion of individual cranial nerves lesions is beyond the scope of this article. (orig.)

  8. Imaging the cranial nerves: Part I: Methodology, infectious and inflammatory, traumatic and congenital lesions

    International Nuclear Information System (INIS)

    Borges, Alexandra; Casselman, Jan

    2007-01-01

    Many disease processes manifest either primarily or secondarily by cranial nerve deficits. Neurologists, ENT surgeons, ophthalmologists and maxillo-facial surgeons are often confronted with patients with symptoms and signs of cranial nerve dysfunction. Seeking the cause of this dysfunction is a common indication for imaging. In recent decades we have witnessed an unprecedented improvement in imaging techniques, allowing direct visualization of increasingly small anatomic structures. The emergence of volumetric CT scanners, higher field MR scanners in clinical practice and higher resolution MR sequences has made a tremendous contribution to the development of cranial nerve imaging. The use of surface coils and parallel imaging allows sub-millimetric visualization of nerve branches and volumetric 3D imaging. Both with CT and MR, multiplanar and curved reconstructions can follow the entire course of a cranial nerve or branch, improving tremendously our diagnostic yield of neural pathology. This review article will focus on the contribution of current imaging techniques in the depiction of normal anatomy and on infectious and inflammatory, traumatic and congenital pathology affecting the cranial nerves. A detailed discussion of individual cranial nerves lesions is beyond the scope of this article. (orig.)

  9. MR imaging of brachial plexus

    International Nuclear Information System (INIS)

    Carriero, A.; Ciccotosto, C.; Dragani, M.; Manes, L.; Bonomo, L.

    1991-01-01

    The brachial plexus is a difficult region to evaluate with radiological techniques. MR imaging has great potentials for the depiction of the various anatomical structures of the branchial plexus - i.e., spinal ganglion, ventral nerve rami root exit of the neural foramina, trunks an cordes. Moreover, MR imaging, thanks to its direct multiplanarity, to its excellent soft-tissue contrast, and to its lack of motion artifacts, allows good evaluation of pathologic conditions in the branchial plexus, especially traumas and cancers. On the contrary CT, in spite of its high spatial resolution and good contrast, cannot demonstrate the anatomical structures of the brachial plexus. US detects superficials structures, and conventional radiographs depict only indirect changes in the adjacent lung apex and skeletal structures. From November 1989 to May 1990, 20 normal volunteers (15 males and 5 females; average age: 35 years) were studied with MR imaging. Multisection technique was employed with a dedicated coil and a primary coil. The anatomical structures of the brachial plexus were clearly demonstrated by T1-weighted sequences on the sagittal and axial planes. T2-weighted pulse sequences on the coronal plane were useful for the anatomical definition of the brachial plexus and for eventual tissue characterization. The correct representation of the anatomical structures of the brachial plexus allowed by MR imaging with author's standard technique makes MR imaging the most appropriate exam for the diagnosis of pathologic conditions in the brachial plexus, although its use must be suggested by specific clinical questions

  10. Proofs that Develop Insight

    Science.gov (United States)

    Weber, Keith

    2010-01-01

    Many mathematics educators have noted that mathematicians do not only read proofs to gain conviction but also to obtain insight. The goal of this article is to discuss what this insight is from mathematicians' perspective. Based on interviews with nine research-active mathematicians, two sources of insight are discussed. The first is reading a…

  11. Imaging of laryngeal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Minerva, E-mail: Minerva.Becker@hcuge.ch [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland); Leuchter, Igor, E-mail: Igor.Leuchter@hcuge.ch [Department of Otorhinolaryngology and Cervico-facial Surgery, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland); Platon, Alexandra, E-mail: Alexandra.Platon@hcuge.ch [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland); Becker, Christoph D., E-mail: Christoph.Becker@hcuge.ch [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland); Dulguerov, Pavel, E-mail: Pavel.Dulguerov@hcuge.ch [Department of Otorhinolaryngology and Cervico-facial Surgery, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland); Varoquaux, Arthur, E-mail: Arthur.Varoquaux@hcuge.ch [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14 (Switzerland)

    2014-01-15

    External laryngeal trauma is a rare but potentially life-threatening situation in the acutely injured patient. Trauma mechanism and magnitude, maximum focus of the applied force, and patient related factors, such as age and ossification of the laryngeal cartilages influence the spectrum of observed injuries. Their correct diagnosis and prompt management are paramount in order to avoid patient death or long-term impairment of breathing, swallowing and speaking. The current review provides a comprehensive approach to the radiologic interpretation of imaging studies performed in patients with suspected laryngeal injury. It describes the key anatomic structures that are relevant in laryngeal trauma and discusses the clinical role of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the acute emergency situation. The added value of two-dimensional multiplanar reconstructions (2D MPR), three-dimensional volume rendering (3D VR) and virtual endoscopy (VE) for the non-invasive evaluation of laryngeal injuries and for treatment planning is discussed. The clinical presentation, biomechanics of injury, diagnostic pitfalls and pearls, common and uncommon findings are reviewed with emphasis of fracture patterns, involvement of laryngeal joints, intra- and extralaryngeal soft tissue injuries, and complications seen in the acute emergency situation. The radiologic appearance of common and less common long-term sequelae, as well as treatment options are equally addressed.

  12. Imaging of laryngeal trauma

    International Nuclear Information System (INIS)

    Becker, Minerva; Leuchter, Igor; Platon, Alexandra; Becker, Christoph D.; Dulguerov, Pavel; Varoquaux, Arthur

    2014-01-01

    External laryngeal trauma is a rare but potentially life-threatening situation in the acutely injured patient. Trauma mechanism and magnitude, maximum focus of the applied force, and patient related factors, such as age and ossification of the laryngeal cartilages influence the spectrum of observed injuries. Their correct diagnosis and prompt management are paramount in order to avoid patient death or long-term impairment of breathing, swallowing and speaking. The current review provides a comprehensive approach to the radiologic interpretation of imaging studies performed in patients with suspected laryngeal injury. It describes the key anatomic structures that are relevant in laryngeal trauma and discusses the clinical role of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the acute emergency situation. The added value of two-dimensional multiplanar reconstructions (2D MPR), three-dimensional volume rendering (3D VR) and virtual endoscopy (VE) for the non-invasive evaluation of laryngeal injuries and for treatment planning is discussed. The clinical presentation, biomechanics of injury, diagnostic pitfalls and pearls, common and uncommon findings are reviewed with emphasis of fracture patterns, involvement of laryngeal joints, intra- and extralaryngeal soft tissue injuries, and complications seen in the acute emergency situation. The radiologic appearance of common and less common long-term sequelae, as well as treatment options are equally addressed

  13. Proof of Principle for Electronic Collimation of a Gamma Ray Detector

    Science.gov (United States)

    2016-01-01

    Approved for public release; distribution is unlimited. ERDC TN-EQT-16-1 January 2016 Proof of Principle for Electronic Collimation of a Gamma...in achieving the proof of principle of the technique, which is intended to be further developed. A gamma ray detector system utilizing electronic...waveforms from longitudinal (along the axis) waveforms yield proof of principle . TECHNOLOGY DESCRIPTION: The component detector technologies were

  14. A short list color proof of Grotzsch's theorem

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2000-01-01

    We give a short proof of the result that every planar graph of girth $5$is $3$-choosable and hence also of Gr\\"{o}tzsch's theorem saying that everyplanar triangle-free graph is $3$-colorable.......We give a short proof of the result that every planar graph of girth $5$is $3$-choosable and hence also of Gr\\"{o}tzsch's theorem saying that everyplanar triangle-free graph is $3$-colorable....

  15. Cone beam CT imaging with limited angle of projections and prior knowledge for volumetric verification of non-coplanar beam radiation therapy: a proof of concept study

    Science.gov (United States)

    Meng, Bowen; Xing, Lei; Han, Bin; Koong, Albert; Chang, Daniel; Cheng, Jason; Li, Ruijiang

    2013-11-01

    registration significantly improved the reconstructed image quality, with a reduction of mostly 2-3 folds (up to 100) in root mean square image error. The proposed algorithm provides a remedy for solving the problem of non-coplanar CBCT reconstruction from limited angle of projections by combining the PICCS technique and rigid image registration in an iterative framework. In this proof of concept study, non-coplanar beams with couch rotations of 45° can be effectively verified with the CBCT technique.

  16. A Calculus of Circular Proofs and its Categorical Semantics

    DEFF Research Database (Denmark)

    Santocanale, Luigi

    2002-01-01

    We present a calculus of “circular proofs”: the graph underlying a proof is not a finite tree but instead it is allowed to contain a certain amount of cycles.The main challenge in developing a theory for the calculus is to define the semantics of proofs, since the usual method by induction...

  17. Atomic resolution images of graphite in air

    Energy Technology Data Exchange (ETDEWEB)

    Grigg, D.A.; Shedd, G.M.; Griffis, D.; Russell, P.E.

    1988-12-01

    One sample used for proof of operation for atomic resolution in STM is highly oriented pyrolytic graphite (HOPG). This sample has been imaged with many different STM`s obtaining similar results. Atomic resolution images of HOPG have now been obtained using an STM designed and built at the Precision Engineering Center. This paper discusses the theoretical predictions and experimental results obtained in imaging of HOPG.

  18. Multiparty Session Types as Coherence Proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2015-01-01

    We propose a Curry-Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof...... normalisation to executing communications. Our key contribution is generalising duality, from CLL, to a new notion of n-ary compatibility, called coherence. Building on coherence as a principle of compositionality, we generalise the cut rule of CLL to a new rule for composing many processes communicating...... in a multiparty session. We prove the soundness of our model by showing the admissibility of our new rule, which entails deadlock-freedom via our correspondence....

  19. Strategy-proof social choice

    OpenAIRE

    Barberà, Salvador, 1946-

    2010-01-01

    This paper surveys the literature on strategy-proofness from a historical perspective. While I discuss the connections with other works on incentives in mechanism design, the main emphasis is on social choice models. This article has been prepared for the Handbook of Social Choice and Welfare, Volume 2, Edited by K. Arrow, A. Sen and K. Suzumura

  20. Proofs with monotone cuts

    Czech Academy of Sciences Publication Activity Database

    Jeřábek, Emil

    2012-01-01

    Roč. 58, č. 3 (2012), s. 177-187 ISSN 0942-5616 R&D Projects: GA AV ČR IAA100190902; GA MŠk(CZ) 1M0545 Institutional support: RVO:67985840 Keywords : proof complexity * monotone sequent calculus Subject RIV: BA - General Mathematics Impact factor: 0.376, year: 2012 http://onlinelibrary.wiley.com/doi/10.1002/malq.201020071/full

  1. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction

    International Nuclear Information System (INIS)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E.; Merten, H.A.

    2002-01-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [de

  2. Encoding Featherweight Java with Assignment and Immutability using The Coq Proof Assistant

    DEFF Research Database (Denmark)

    Mackay, Julian; Mehnert, Hannes; Potanin, Alex

    2012-01-01

    We develop a mechanized proof of Featherweight Java with Assignment and Immutability in the Coq proof assistant. This is a step towards more machine-checked proofs of a non-trivial type system. We used object immutability close to that of IGJ [9] . We describe the challenges of the mech- anisation...

  3. On mathematicians' different standards when evaluating elementary proofs.

    Science.gov (United States)

    Inglis, Matthew; Mejia-Ramos, Juan Pablo; Weber, Keith; Alcock, Lara

    2013-04-01

    In this article, we report a study in which 109 research-active mathematicians were asked to judge the validity of a purported proof in undergraduate calculus. Significant results from our study were as follows: (a) there was substantial disagreement among mathematicians regarding whether the argument was a valid proof, (b) applied mathematicians were more likely than pure mathematicians to judge the argument valid, (c) participants who judged the argument invalid were more confident in their judgments than those who judged it valid, and (d) participants who judged the argument valid usually did not change their judgment when presented with a reason raised by other mathematicians for why the proof should be judged invalid. These findings suggest that, contrary to some claims in the literature, there is not a single standard of validity among contemporary mathematicians. Copyright © 2013 Cognitive Science Society, Inc.

  4. US NDC Modernization: Service Oriented Architecture Proof of Concept

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, Benjamin R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Encarnacao, Andre Villanova [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jackson, Keilan R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hays, Ian A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Barron, Nathan E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Simon, Luke B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Harris, James M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Young, Christopher J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-12-01

    This report is a progress update on the US NDC Modernization Service Oriented Architecture (SOA) study describing results from a proof of concept project completed from May through September 2013. Goals for this proof of concept are 1) gain experience configuring, using, and running an Enterprise Service Bus (ESB), 2) understand the implications of wrapping existing software in standardized interfaces for use as web services, and 3) gather performance metrics for a notional seismic event monitoring pipeline implemented using services with various data access and communication patterns. The proof of concept is a follow on to a previous SOA performance study. Work was performed by four undergraduate summer student interns under the guidance of Sandia staff.

  5. Imaging the cranial nerves: part II: primary and secondary neoplastic conditions and neurovascular conflicts

    International Nuclear Information System (INIS)

    Borges, Alexandra; Casselman, Jan

    2007-01-01

    There have been unprecedented improvements in cross-sectional imaging in the last decades. The emergence of volumetric CT, higher field MR scanners and higher resolution MR sequences is largely responsible for the increasing diagnostic yield of imaging in patients presenting with cranial nerve deficits. The introduction of parallel MR imaging in combination with small surface coils allows the depiction of submillimetric nerves and nerve branches, and volumetric CT and MR imaging is able to provide high quality multiplanar and curved reconstructions that can follow the often complex course of cranial nerves. Seeking the cause of a cranial nerve deficit is a common indication for imaging, and it is not uncommon that radiologists are the first specialists to see a patient with a cranial neuropathy. To increase the diagnostic yield of imaging, high-resolution studies with smaller fields of view are required. To keep imaging studies within a reasonable time frame, it is mandatory to tailor the study according to neuro-topographic testing. This review article focuses on the contribution of current imaging techniques in the depiction of primary and secondary neoplastic conditions affecting the cranial nerves as well as on neurovascular conflicts, an increasingly recognized cause of cranial neuralgias. (orig.)

  6. Imaging the cranial nerves: part II: primary and secondary neoplastic conditions and neurovascular conflicts

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Instituto Portugues de Oncologia Francisco Gentil- Centro de Lisboa, Radiology Department, Lisboa Codex (Portugal); Casselman, Jan [A. Z. St Jan Brugge and A. Z. St Augustinus Antwerpen Hospitals, Department of Radiology, Antwerp (Belgium)

    2007-09-15

    There have been unprecedented improvements in cross-sectional imaging in the last decades. The emergence of volumetric CT, higher field MR scanners and higher resolution MR sequences is largely responsible for the increasing diagnostic yield of imaging in patients presenting with cranial nerve deficits. The introduction of parallel MR imaging in combination with small surface coils allows the depiction of submillimetric nerves and nerve branches, and volumetric CT and MR imaging is able to provide high quality multiplanar and curved reconstructions that can follow the often complex course of cranial nerves. Seeking the cause of a cranial nerve deficit is a common indication for imaging, and it is not uncommon that radiologists are the first specialists to see a patient with a cranial neuropathy. To increase the diagnostic yield of imaging, high-resolution studies with smaller fields of view are required. To keep imaging studies within a reasonable time frame, it is mandatory to tailor the study according to neuro-topographic testing. This review article focuses on the contribution of current imaging techniques in the depiction of primary and secondary neoplastic conditions affecting the cranial nerves as well as on neurovascular conflicts, an increasingly recognized cause of cranial neuralgias. (orig.)

  7. Perfect imaging without negative refraction

    OpenAIRE

    Leonhardt, Ulf

    2009-01-01

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively-refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing ma...

  8. Simplifying the exploration of volumetric images: development of a 3D user interface for the radiologist's workplace.

    Science.gov (United States)

    Teistler, M; Breiman, R S; Lison, T; Bott, O J; Pretschner, D P; Aziz, A; Nowinski, W L

    2008-10-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented within a virtual 3D scene together with the volume-rendered data set and additionally as 2D images. Slabs are visualized with maximum intensity projection, average intensity projection, or standard volume rendering technique. A prototype has been implemented based on PC technology that has been tested by several radiologists. It has shown to be easily understandable and usable after a very short learning phase. Our solution may help to fully exploit the diagnostic potential of volumetric imaging by allowing for a more efficient reading process compared to currently deployed solutions based on conventional mouse and keyboard.

  9. Tree Resolution Proofs of the Weak Pigeon-Hole Principle

    DEFF Research Database (Denmark)

    Dantchev, Stefan Stajanov; Riis, Søren

    2001-01-01

    We prove that any optimal tree resolution proof of PHPn m is of size 2&thetas;(n log n), independently from m, even if it is infinity. So far, only a 2Ω(n) lower bound has been known in the general case. We also show that any, not necessarily optimal, regular tree resolution proof PHPn m is bound...

  10. Mediastinal and hilar lymphadenopathy: cross-referenced anatomy on axial and coronal images displayed by using multi-detector row CT

    International Nuclear Information System (INIS)

    Lee, Ju Hyun; Lee, Kyung Soo; Kim, Tae Sung; Yi, Chin A; Cho, Jae Min; Lee, Min Hee

    2003-01-01

    The accurate evaluation of mediastinal and pulmonary hilar lymphadenopathy, especially in patients with lung cancer, is important for determining treatment options and evaluating the response to therapy. To indicate nodal location in detail, mediastinal and hilar lymph nodes have been assigned to one of 14 nodal stations. Mediastinal nodes of greater than 10 mm short-axis diameter are regarded as abnormal, irrespective of their nodal station, while hilar nodes are considered abnormal if their diameter is greater than 10 mm in any axis or they are convex compared to surrounding lung. By providing multiplanar images, multi-detector row CT allows detailed evaluation of thoracic anatomic structures more easily than in the past, when axial images only were available. At cross-referenced imaging, a lymph node depicted at axial imaging in one anatomical location can be visualized simultaneously and automatically at coronal imaging at the exactly corresponding anatomical location. Cross-referenced coincidental axial and coronal images help assess both the size and morphology of mediastinal and hilar lymph nodes

  11. A Forward-secure Grouping-proof Protocol for Multiple RFID Tags

    Directory of Open Access Journals (Sweden)

    Liu Ya-li

    2012-09-01

    Full Text Available Designing secure and robust grouping-proof protocols based on RFID characteristics becomes a hotspot in the research of security in Internet of Things (IOT. The proposed grouping-proof protocols recently have security and/or privacy omission and these schemes afford order-dependence by relaying message among tags through an RFID reader. In consequence, aiming at enhancing the robustness, improving scalability, reducing the computation costs on resource-constrained devices, and meanwhile combing Computational Intelligence (CI with Secure Multi-party Communication (SMC, a Forward-Secure Grouping-Proof Protocol (FSGP for multiple RFID tags based on Shamir's (, secret sharing is proposed. In comparison with the previous grouping-proof protocols, FSGP has the characteristics of forward-security and order-independence addressing the scalability issue by avoiding relaying message. Our protocol provides security enhancement, performance improvement, and meanwhile controls the computation cost, which equilibrates both security and low cost requirements for RFID tags.

  12. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    International Nuclear Information System (INIS)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  13. Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

    Science.gov (United States)

    Li, Ke; Ge, Yongshuai; Garrett, John; Bevins, Nicholas; Zambelli, Joseph; Chen, Guang-Hong

    2014-01-01

    Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS

  14. Traumatic cervical root injury: Diagnostic value of MR imaging

    International Nuclear Information System (INIS)

    Lee, Seon Kyu; Chang, Kee Hyun; Han, Moon Hee; Kim, Ho Chul; Kim, Jea Seung; Cha, Sang Hoon

    1993-01-01

    Although superior soft tissue contrast and direct multiplanar imaging capability of MRI are well recognized, myelography has been the imaging modality of choice in evaluation cervical root injury. We assessed the role of MRI and compared its diagnostic accuracy with myelography in the evaluation of cervical root injury. MR imagings of cervical root injury in ten patients (55 roots) were retrospectively reviewed. In 26 explored roots (6 patients). MR findings were compared with myelography and surgical results. In 29 roots (8 patients), which were confirmed by myelography or exploration, the MR findings were focal extradural CSF collections (pseudomeningocele) in 21/29 (72.4%, 8 patients), thickening of extradural roots in 4/29 (13.6%, 5 patients), and thickening of dura in 12/29 (41.4%, 6 patients) roots. T2-weighted axial image was superior to T1-weighted and protein-density- weighted images for delineation root avulsion. The sensitivity and specificity of MRI were 72.7% and 93.3% respectively, while those of myelography were 83% and 90%. Overall diagnostic accuracy of MRI and myelography were comparable (84.6% vs 87.5%). In conclusion, myelography is still considered as the modality of choice in the preoperative evaluation of the cervical root avulsion because of its higher sensitivity. MRI, however, may obviate the myelography with some technical refinements

  15. Proof testing of CANDU concrete containment structures

    International Nuclear Information System (INIS)

    Pandey, M.D.

    1996-05-01

    Prior to commissioning of a CANDU reactor, a proof pressure test is required to demonstrate the structural integrity of the containment envelope. The test pressure specified by AECB Regulatory Document R-7 (1991) was selected without a rigorous consideration of uncertainties associated with estimates of accident pressure and conatinment resistance. This study was undertaken to develop a reliability-based philosophy for defining proof testing requirements that are consistent with the current limit states design code for concrete containments (CSA N287.3).It was shown that the upodated probability of failure after a successful test is always less than the original estimate

  16. Structuring Interactive Correctness Proofs by Formalizing Coding Idioms

    OpenAIRE

    Gast, Holger

    2012-01-01

    This paper examines a novel strategy for developing correctness proofs in interactive software verification for C programs. Rather than proceeding backwards from the generated verification conditions, we start by developing a library of the employed data structures and related coding idioms. The application of that library then leads to correctness proofs that reflect informal arguments about the idioms. We apply this strategy to the low-level memory allocator of the L4 microkernel, a case st...

  17. Imaging by magnetic resonance of pigmented villonodular synovitis

    International Nuclear Information System (INIS)

    Hernandez Moreno, L.; Lafuente Martinez, J.; Marti Bonmati, L.; Perez Diaz, M.; Vilar Samper, J.; Paniagua, J.C.

    1994-01-01

    Magnetic resonance (MR) has become the method of choice for evaluating a large number of musculoskeletal disorders, especially because of its capacity to provide multiplanar tomographic sections and its greater contrast resolution as compared to other imaging methods. This report present seven cases of pigmented villonodular synovitis (PVS) located in joints. In six cases, the diagnosis was suggested by MR on the basis of the fact that the lesions showed hypointense areas with no signal in both the T1 and T2-weighted sequences. This is due to hemosiderin deposition in the lesion. In addition to its diagnostic value, in this disorder, MR is an excellent method for assessing the exact extension and location of the lesions, as well as the follow-up to these patients and the detection of possible recurrences. (Author) 17 refs

  18. 33 CFR 136.215 - Proof.

    Science.gov (United States)

    2010-07-01

    ... FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY TRUST FUND; CLAIMS PROCEDURES; DESIGNATION OF SOURCE; AND ADVERTISEMENT Procedures for Particular Claims § 136.215 Proof. (a) In addition to the... each claim for economic loss resulting from destruction of real or personal property, the claimant must...

  19. IFA proof of principle experiments

    International Nuclear Information System (INIS)

    Olson, C.L.

    1979-01-01

    IFA proof of principle experiments is discussed. Controlled beam front motion experiments are reported, which demonstrate that accurate IFA programming of the motion of the potential well at the head of an IREB has been achieved. The status of IFA ion experiments is also discussed

  20. Secondary Teachers' Knowledge of Elementary Number Theory Proofs: The Case of General-Cover Proofs

    Science.gov (United States)

    Tabach, Michal; Levenson, Esther; Barkai, Ruthi; Tsamir, Pessia; Tirosh, Dina; Dreyfus, Tommy

    2011-01-01

    In light of recent reform recommendations, teachers are expected to turn proofs and proving into an ongoing component of their classroom practice. Two questions emerging from this requirement are: Is the mathematical knowledge of high school teachers sufficient to prove various kinds of statements? Does teachers' knowledge allow them to determine…

  1. New zero-input overflow stability proofs based on Lyapunov theory

    NARCIS (Netherlands)

    Werter, M.J.; Ritzerfeld, J.H.F.

    1989-01-01

    The authors demonstrate some proofs of zero-input overflow-oscillation suppression in recursive digital filters. The proofs are based on the second method of Lyapunov. For second-order digital filters with complex conjugated poles, the state describes a trajectory in the phase plane, spiraling

  2. Magnetic Resonance Imaging versus Computed Tomography and Different Imaging Modalities in Evaluation of Sinonasal Neoplasms Diagnosed by Histopathology

    Directory of Open Access Journals (Sweden)

    Mohammed A. Gomaa

    2013-01-01

    Full Text Available Objective The study purpose was to detect the value of magnetic resonance imaging (MRI compared to computed tomography (CT and different imaging modalities as conventional radiology in evaluation of sinonasal neoplasms diagnosed by Histopathology. Methods Thirty patients (16 males and 14 females were complaining of symptoms related to sinonasal tract. After thorough clinical and local examination, the patients were subjected to the following: conventional radiography, CT, MRI, and histopathological examination. Results The nasal cavity was the most commonly involved site with sinonasal malignancies followed by the maxillary sinuses. The least commonly affected site was the frontal sinuses. Benign sinonasal tumors were present in 14 cases. The most common benign lesion was juvenile nasopharyngeal angiofibroma (6 cases, followed by inverted papilloma (3 cases. While malignant sinonasal tumors were present in 16 cases, squamous cell carcinoma was present in 5 cases, and undifferentiated carcinoma, in 3 cases. Lymphoepithelioma and non-Hodgkin lymphomas were present in 2 cases each, while adenocarcinoma, chondrosarcoma, adenoid cystic carcinoma, and rhabdomyosarcoma were present in 1 case each. Conclusion MRI with its superior soft tissue contrast and multiplanar capability is superior to CT in pretreatment evaluation of primary malignant tumors of sinonasal cavity.

  3. Don’t get caught out! A rare case of a calcified urachal remnant mimicking a bladder calculus

    Science.gov (United States)

    Rodrigues, Jonathan Carl Luis; Gandhi, Sanjay

    2013-01-01

    Computer tomography through the kidneys, ureters and bladder (CT KUB) is the mainstay investigation of suspected renal tract calculi. However, several pathologies other than renal tract calculi can cause apparent urinary bladder calcification. We describe the case of a 45 year old man who presented with left sided renal colic. Prone CT KUB performed on admission revealed a calcified urachal remnant mimicking a urinary bladder calculus in the dependent portion of the urinary bladder, confirmed by reviewing the multi-planar reformatted images. This is the first reported case in the literature of this phenomenon. We discuss the importance of using multi-planar reformatted images (MPR) and maximum intensity projection images (MIP), as well as careful review of previous imaging, in making the correct diagnosis. We also discuss the differential diagnoses that should be considered when presented with urinary bladder calcification. PMID:23705044

  4. Sinonasal imaging after Caldwell-Luc surgery: MDCT findings of an abandoned procedure in times of functional endoscopic sinus surgery

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Peloschek, Philipp; Koelblinger, Claus; Mehrain, Sheida; Krestan, Christian Robert; Czerny, Christian

    2009-01-01

    Background and purpose: Today, functional endoscopic sinus surgery (FESS) is performed in most of the patients with sinonasal inflammatory disease. The postoperative imaging findings of FESS in multidetector computed tomography (MDCT) considerably differ from those of historic Caldwell-Luc (CL) maxillary sinus surgery which is an uncommon procedure today. Thus, the postoperative CL imaging findings may lead to diagnostic confusion and misinterpretation. Therefore, this study explicitly presents the MDCT findings of post-CL patients which have not been described previously. Methods: Twenty-eight patients with clinically suspected sinusitis and documented history of CL-procedure underwent 16 row MDCT (MDCT Mx8000 IDT Philips) with multiplanar reconstructions of the paranasal sinuses in the axial plane. The following parameters were used: 140 kV, 50 mAs; 16 mm x 0.75 mm detector collimation; 1 mm reconstructed slice thickness; 0.5 mm increment. The studies were reconstructed with a bone algorithm (W3000/L600; 1 mm slice thickness) in axial plane and coronal plane (3 mm slice thickness). The images were retrospectively evaluated for the presence of normal surgery-related and pathological findings. Results: Surgery-related imaging characteristics presented as follows: an anterior and a medial bony wall defect and sclerosis and sinus wall thickening were observed in all 28/28 cases (100%). Collaps of the sinus cavity was seen in 26/28 cases (92.9%). Furthermore, inflammatory disease of the operated sinus(es) was found in 23/28 cases (82.1%): 14/28 patients (50%) had inflammatory mucosal thickening of the operated sinus(es) as well as of other sinonasal cavities and 9/28 patients (32.1%) had inflammatory mucosal thickening limited to the operated sinus(es). A postoperative mucocele was depicted in 3/28 cases (10.7%). 2/28 patients (7.1%) showed neither maxillary nor other mucosal swelling. Conclusion: MDCT with multiplanar reconstructions is a precise method to evaluate

  5. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  6. An imaging checklist for pre-FESS CT: framing a surgically relevant report

    Energy Technology Data Exchange (ETDEWEB)

    Vaid, S., E-mail: vaids@vsnl.co [Department of Radiology and Imaging, Grant Medical Foundation, Pune (India); Vaid, N. [Department of Otorhinolaryngology, K.E.M. Hospital, Pune (India); Rawat, S. [Department of Radiology and Imaging, Grant Medical Foundation, Pune (India); Ahuja, A.T. [Department of Diagnostic Radiology and Organ Imaging, The Chinese University of Hong Kong (Hong Kong)

    2011-05-15

    The reference standard for preoperative imaging in functional endoscopic sinus surgery (FESS) is multiplanar high-resolution computed tomography (HRCT). Surgeons require a precise preoperative anatomical road map, and hence it is essential for radiologists to be familiar with the normal three-dimensional sinonasal anatomy and the normal variants encountered in this region. Sagittal imaging has recently emerged as an important tool to visualize additional details in this critical anatomical region. Radiologists also need to report these examinations with special focus on the surgeon's expectations. Constant communication between the radiologist and the surgeon helps to resolve specific issues and improve the overall quality of reports. This results in better preoperative patient counselling and in predicting postoperative improvement in clinical status. This review provides a basic structured format for reporting pre-FESS CT, which can be tailored to meet individual requirements. The CT reporting format follows the order in which the sinonasal structures are approached during surgery.

  7. Surgical stent for dental implant using cone beam CT images

    International Nuclear Information System (INIS)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  8. A correctness proof of the bakery protocol in $ mu $CRL

    NARCIS (Netherlands)

    J.F. Groote (Jan Friso); H.P. Korver

    1994-01-01

    textabstractA specification of a bakery protocol is given in $mu$CRL. We provide a simple correctness criterion for the protocol. Then the protocol is proven correct using a proof system that has been developed for $mu$CRL. The proof primarily consists of algebraic manipulations based on

  9. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  10. Evaluation of the marsh deer stifle joint by imaging studies and gross anatomy.

    Science.gov (United States)

    Shigue, D A; Rahal, S C; Schimming, B C; Santos, R R; Vulcano, L C; Linardi, J L; Teixeira, C R

    2015-12-01

    This study aimed to evaluate the stifle joint of marsh deer using imaging studies and in comparison with gross anatomy. Ten hindlimbs from 5 marsh deer (Blastocerus dichotomus) were used. Radiography, computed tomography (CT) and magnetic resonance imaging (MRI) were performed in each stifle joint. Two hindlimbs were dissected to describe stifle gross anatomy. The other limbs were sectioned in sagittal, dorsal or transverse planes. In the craniocaudal radiographic view, the lateral femoral condyle was broader than the medial femoral condyle. The femoral trochlea was asymmetrical. Subsequent multiplanar reconstruction revealed in the cranial view that the external surface of the patella was roughened, the medial trochlea ridge was larger than the lateral one, and the extensor fossa at the lateral condyle was next to the lateral ridge. The popliteal fossa was better visualized via the lateral view. Sagittal MRI images identified lateral and medial menisci, caudolateral and craniomedial bundles of cranial cruciate ligament, caudal cruciate ligament, patellar ligament and common extensor tendon. In conclusion, the marsh deer stifle presents some anatomical characteristics of the ovine stifle joint. © 2014 Blackwell Verlag GmbH.

  11. Peac – A set of tools to quickly enable Proof on a cluster

    International Nuclear Information System (INIS)

    Ganis, G; Vala, M

    2012-01-01

    With advent of the analysis phase of Lhcdata-processing, interest in Proof technology has considerably increased. While setting up a simple Proof cluster for basic usage is reasonably straightforward, exploiting the several new functionalities added in recent times may be complicated. Peac, standing for Proof Enabled Analysis Cluster, is a set of tools aiming to facilitate the setup and management of a Proof cluster. Peac is based on the experience made by setting up Proof for the Alice analysis facilities. It allows to easily build and configure Root and the additional software needed on the cluster, and may serve as distributor of binaries via Xrootd. Peac uses Proof-On-Demand (PoD) for resource management (start, stop or daemons). Finally, Peac sets-up and configures dataset management (using the Afdsmgrd daemon), as well as cluster monitoring (machine status and Proof query summaries) using MonAlisa. In this respect, a MonAlisa page has been dedicated to Peac users, so that a cluster managed by Peac can be automatically monitored. In this paper we present and describe the status and main components of Peac and show details about its usage.

  12. Proofs of the Kochen–Specker theorem based on a system of three qubits

    International Nuclear Information System (INIS)

    Waegell, Mordecai; Aravind, P K

    2012-01-01

    A number of new proofs of the Kochen–Specker theorem are given based on the observables of the three-qubit Pauli group. Each proof is presented in the form of a diagram from which it is obvious by inspection. Each of our observable-based proofs leads to a system of projectors and bases that generally yields a large number of ‘parity proofs’ of the Kochen–Specker theorem. Some examples of such proofs are given and some of their applications are discussed. (paper)

  13. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  14. High school mathematics teachers' perspectives on the purposes of mathematical proof in school mathematics

    Science.gov (United States)

    Dickerson, David S.; Doerr, Helen M.

    2014-12-01

    Proof serves many purposes in mathematics. In this qualitative study of 17 high school mathematics teachers, we found that these teachers perceived that two of the most important purposes for proof in school mathematics were (a) to enhance students' mathematical understanding and (b) to develop generalized thinking skills that were transferable to other fields of endeavor. We found teachers were divided on the characteristics (or features) of proofs that would serve these purposes. Teachers with less experience tended to believe that proofs in the high school should adhere to strict standards of language and reasoning while teachers with more experience tended to believe that proofs based on concrete or visual features were well suited for high school mathematics. This study has implications for teacher preparation because it appears that there is a wide variation in how teachers think about proof. It seems likely that students would experience proof very differently merely because they were seated in different classrooms.

  15. A Correctness Proof of the Bakery Protocol in μCRL

    NARCIS (Netherlands)

    Groote, J.F.; Korver, H.

    1992-01-01

    A specification of the bakery protocol is given in μCRL. We provide a simple correctness criterion for the protocol. Then the protocol is proven correct using a proof system that has been developed for μCRL. The proof primarily consists of algebraic manipulations based on specifications of

  16. 30 CFR 18.62 - Tests to determine explosion-proof characteristics.

    Science.gov (United States)

    2010-07-01

    ... characteristics. 18.62 Section 18.62 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Inspections and Tests § 18.62 Tests to determine explosion-proof characteristics. (a) In testing for explosion-proof characteristics of an enclosure, it shall be filled and surrounded with various explosive mixtures...

  17. A Proof-checked Verification of a Real-Time Communication Protocol

    NARCIS (Netherlands)

    Polak, I.

    We present an analysis of a protocol developed by Philips to connect several components of an audio-system. The verification of the protocol is carried out using the timed I/O-automata model of Lynch and Vaandrager. The verification has been partially proof-checked with the interactive proof

  18. Computer-Assisted Discovery and Proof

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2007-12-10

    With the advent of powerful, widely-available mathematical software, combined with ever-faster computer hardware, we are approaching a day when both the discovery and proof of mathematical facts can be done in a computer-assisted manner. his article presents several specific examples of this new paradigm in action.

  19. Proof Rules for Recursive Procedures

    NARCIS (Netherlands)

    Hesselink, Wim H.

    1993-01-01

    Four proof rules for recursive procedures in a Pascal-like language are presented. The main rule deals with total correctness and is based on results of Gries and Martin. The rule is easier to apply than Martin's. It is introduced as an extension of a specification format for Pascal-procedures, with

  20. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  1. Toda molecule and Tomimatsu-Sato solution-towards the complete proof of Nakamura's conjecture

    International Nuclear Information System (INIS)

    Fukuyama, Takeshi; Koizumi, Kozo

    2011-01-01

    We discuss the Nakamura's conjecture stating that the Tomimatsu-Sato black hole solution with an integer deformation parameter n is composed of the special solutions of the Toda molecule equation at the nth lattice site. From the previous work, in which the conjecture was partly analytically proved, we go further towards the final full proof by rearranging the rotation parameter. The proof is explicitly performed for the highest and lowest orders. Though the proof for all orders still remains unsolved, the prospect to the full proof becomes transparent and workable by our method. (paper)

  2. The bounded proof property via step algebras and step frames

    NARCIS (Netherlands)

    Bezhanishvili, N.; Ghilardi, Silvio

    2013-01-01

    We develop a semantic criterion for a specific rule-based calculus Ax axiomatizing a given logic L to have the so-called bounded proof property. This property is a kind of an analytic subformula property limiting the proof search space. Our main tools are one-step frames and one-step algebras. These

  3. An Examination of Undefined Forms of Proof in Academic Debate.

    Science.gov (United States)

    Underwood, Willard A.

    Although texts on debate and argumentation deal with accepted forms of evidence, reasoning, and logical methods of proof, they do not cover adequately the "undefined" forms of proof. Criteria of evidence found in forensic literature are not always followed strictly by judges, in courtroom or classroom. Many debate judges allow imprecise, vague, or…

  4. Coqoon - An IDE for Interactive Proof Development in Coq

    OpenAIRE

    Faithfull, Alexander; Bengtson, Jesper; Tassi, Enrico

    2016-01-01

    User interfaces for interactive proof assistants have always lagged behind those for mainstream programming languages. Whereas integrated development environments—IDEs—have support for features like project management, version control, dependency analysis and incremental project compilation, “IDE”s for proof assistants typically only operate on files in isolation, relying on external tools to integrate those files into larger projects. In this paper we present Coqoon, an IDE for Coq developme...

  5. Forensic devices for activism: Metadata tracking and public proof

    Directory of Open Access Journals (Sweden)

    Lonneke van der Velden

    2015-10-01

    Full Text Available The central topic of this paper is a mobile phone application, ‘InformaCam’, which turns metadata from a surveillance risk into a method for the production of public proof. InformaCam allows one to manage and delete metadata from images and videos in order to diminish surveillance risks related to online tracking. Furthermore, it structures and stores the metadata in such a way that the documentary material becomes better accommodated to evidentiary settings, if needed. In this paper I propose InformaCam should be interpreted as a ‘forensic device’. By using the conceptualization of forensics and work on socio-technical devices the paper discusses how InformaCam, through a range of interventions, rearranges metadata into a technology of evidence. InformaCam explicitly recognizes mobile phones as context aware, uses their sensors, and structures metadata in order to facilitate data analysis after images are captured. Through these modifications it invents a form of ‘sensory data forensics'. By treating data in this particular way, surveillance resistance does more than seeking awareness. It becomes engaged with investigatory practices. Considering the extent by which states conduct metadata surveillance, the project can be seen as a timely response to the unequal distribution of power over data.

  6. Active spectral imaging nondestructive evaluation (SINDE) camera

    Energy Technology Data Exchange (ETDEWEB)

    Simova, E.; Rochefort, P.A., E-mail: eli.simova@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2016-06-15

    A proof-of-concept video camera for active spectral imaging nondestructive evaluation has been demonstrated. An active multispectral imaging technique has been implemented in the visible and near infrared by using light emitting diodes with wavelengths spanning from 400 to 970 nm. This shows how the camera can be used in nondestructive evaluation to inspect surfaces and spectrally identify materials and corrosion. (author)

  7. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development

    Energy Technology Data Exchange (ETDEWEB)

    Huisman, Thierry A.G.M.; Kubik-Huch, Rahel; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, 8091 Zurich (Switzerland); Martin, Ernst [Department of Neuroradiology and Magnetic Resonance, University Children' s Hospital, 8091 Zurich (Switzerland)

    2002-08-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. (orig.)

  8. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Kubik-Huch, Rahel; Marincek, Borut; Martin, Ernst

    2002-01-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. (orig.)

  9. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development.

    Science.gov (United States)

    Huisman, Thierry A G M; Martin, Ernst; Kubik-Huch, Rahel; Marincek, Borut

    2002-08-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality.

  10. Imaging of Pericardiophrenic Bundles Using Multislice Spiral Computed Tomography for Phrenic Nerve Anatomy.

    Science.gov (United States)

    Wang, Yan-Jing; Liu, Lin; Zhang, Meng-Chao; Sun, Huan; Zeng, Hong; Yang, Ping

    2016-08-01

    Phrenic nerve injury and diaphragmatic stimulation are common complications following arrhythmia ablation and pacing therapies. Preoperative comprehension of phrenic nerve anatomy via non-invasive CT imaging may help to minimize the electrophysiological procedure-related complications. Coronary CT angiography data of 121 consecutive patients were collected. Imaging of left and right pericardiophrenic bundles was performed with volume rendering and multi-planar reformation techniques. The shortest spatial distances between phrenic nerves and key electrophysiology-related structures were determined. The frequencies of the shortest distances ≤5 mm, >5 mm and direct contact between phrenic nerves and adjacent structures were calculated. Left and right pericardiophrenic bundles were identified in 86.8% and 51.2% of the patients, respectively. The right phrenic nerve was phrenic nerve, phrenic nerve was phrenic nerve had a distance phrenic nerve showed a distance phrenic nerve anatomy, which might facilitate avoidance of the phrenic nerve-related complications in interventional electrophysiology. © 2016 Wiley Periodicals, Inc.

  11. All-versus-nothing proofs with n qubits distributed between m parties

    International Nuclear Information System (INIS)

    Cabello, Adan; Moreno, Pilar

    2010-01-01

    All-versus-nothing (AVN) proofs show the conflict between Einstein, Podolsky, and Rosen's elements of reality and the perfect correlations of some quantum states. Given an n-qubit state distributed between m parties, we provide a method with which to decide whether this distribution allows an m-partite AVN proof specific for this state using only single-qubit measurements. We apply this method to some recently obtained n-qubit m-particle states. In addition, we provide all inequivalent AVN proofs with less than nine qubits and a minimum number of parties.

  12. All-versus-nothing proofs with n qubits distributed between m parties

    Science.gov (United States)

    Cabello, Adán; Moreno, Pilar

    2010-04-01

    All-versus-nothing (AVN) proofs show the conflict between Einstein, Podolsky, and Rosen’s elements of reality and the perfect correlations of some quantum states. Given an n-qubit state distributed between m parties, we provide a method with which to decide whether this distribution allows an m-partite AVN proof specific for this state using only single-qubit measurements. We apply this method to some recently obtained n-qubit m-particle states. In addition, we provide all inequivalent AVN proofs with less than nine qubits and a minimum number of parties.

  13. Affecting the Flow of a Proof by Creating Presence--A Case Study in Number Theory

    Science.gov (United States)

    Gabel, Mika; Dreyfus, Tommy

    2017-01-01

    The notion of flow of a proof encapsulates mathematical, didactical, and contextual aspects of proof presentation. A proof may have different flows, depending on the lecturer's choices regarding its presentation. Adopting Perelman's New Rhetoric (PNR) as a theoretical framework, we designed methods to assess aspects of the flow of a proof. We…

  14. An evaluation of the pressure proof test concept for 2024-T3 aluminium alloy sheet

    Science.gov (United States)

    Dawicke, D. S.; Poe, C. C., Jr.; Newman, J. C.; Harris, C. E.

    1991-01-01

    The concept of pressure proof testing of fuselage structures with fatigue cracks to insure structural integrity was evaluated from a fracture mechanics viewpoint. A generic analytical and experimental investigation was conducted on uniaxially loaded flat panels with crack configurations and stress levels typical of longitudinal lap splice joints in commercial transport aircraft fuselages. The results revealed that the remaining fatigue life after a proof cycle was longer than that without the proof cycle because of crack growth retardation due to increased crack closure. However, based on a crack length that is slightly less than the critical value at the maximum proof stress, the minimum assured life or proof test interval must be no more than 550 pressure cycles for a 1.33 proof factor and 1530 pressure cycles for a 1.5 proof factor to prevent in-flight failures.

  15. [Imaging of pelvic organ prolapse].

    Science.gov (United States)

    Lapray, Jean-François

    2013-01-01

    Colpocystodefecography (CCD) and dynamic MRI with defecography (MRId) allow an alternation between filling and emptying the hollow organs and the maximum abdominal strain offered by the defecation. When applied in imaging these two principles reveal the masked or underestimated prolapses at the time of the physical examination. A rigorous application of the technique guarantees almost equivalent results from the two examinations. The CCD provides voiding views and improved analysis of the anorectal pathology (intussusception, anismus) but involves radiation and a more invasive examination. MRId has the advantage of providing continuous visibility of the peritoneal compartment, and a multiplanar representation, enabling an examination of the morphology of the pelvic organs and of the supporting structures, with the disadvantage of still necessitating a supine examination, resulting sometimes in an incomplete or impossible evacuation. The normal and abnormal results (cystoptosis, vaginal vault prolapse, enterocele, anorectal intussuception, rectocele, descending perineum, urinary and fecal incontinence) and the respective advantages and limits of the various imaging methods are detailed. Dynamic perineal and introital ultrasound remains more limited in the appreciation of posterior colpoceles and especially in anorectal disorders, than CCD or MRId. Endoanal ultrasound is the first line morphological evaluation of the anal sphincter. Transvaginal and introital ultrasound can detect some complications of suburethral tapes and meshes. Morphological and dynamic imaging are essential complementary tools to the physical examination, especially when a precise anatomic assessment is required to understand the functional complaint or when a reintervention is needed.

  16. Special integrals of Gradshteyn and Ryzhik the proofs

    CERN Document Server

    Moll, Victor H

    2014-01-01

    A Guide to the Evaluation of IntegralsSpecial Integrals of Gradshetyn and Ryzhik: The Proofs provides self-contained proofs of a variety of entries in the frequently used table of integrals by I.S. Gradshteyn and I.M. Ryzhik. The book gives the most elementary arguments possible and uses Mathematica® to verify the formulas. Readers discover the beauty, patterns, and unexpected connections behind the formulas.Volume I collects 15 papers from Revista Scientia covering logarithmic integrals, the gamma function, trigonometric integrals, the beta function, the digamma function, the incomplete beta

  17. PROTECTORS FOR PROOFING OF IRON-CARBON-ALLOYS FROM CORROSIVE EFFECT

    Directory of Open Access Journals (Sweden)

    A. A. Pivovarchyk

    2017-01-01

    Full Text Available The article presents the results of practical testing of the developed compositions of protectors for proofing of low-carbon alloys used in the automotive industry and made from melting stocks of secondary aluminum raw materials. The results of the study of the effectiveness of the proofing of the developed protectors are presented.

  18. 26 CFR 1.871-4 - Proof of residence of aliens.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Proof of residence of aliens. 1.871-4 Section 1... (CONTINUED) INCOME TAXES Nonresident Aliens and Foreign Corporations § 1.871-4 Proof of residence of aliens... alien within the United States has acquired residence therein for purposes of the income tax. (b...

  19. Using metrics for proof rules for recursively defined delay-insensitive specifications

    NARCIS (Netherlands)

    Mallon, WC; Udding, JT

    1997-01-01

    An advantage of algebraic specifications of delay insensitive asynchronous processes over most other formalisms is that it allows the recursive definition of processes, and correctness proofs of an implementation through fixpoint induction. On the other hand, proofs by fixpoint induction are

  20. Teaching logic using a state-of-art proof assistant

    Directory of Open Access Journals (Sweden)

    Maxim Hendriks

    2010-06-01

    Full Text Available This article describes the system ProofWeb developed for teaching logic to undergraduate computer science students. The system is based on the higher order proof assistant Coq, and is made available to the students through an interactive web interface. Part of this system is a large database of logic problems. This database will also hold the solutions of the students. The students do not need to install anything to be able to use the system (not even a browser plug-in, and the teachers are able to centrally track progress of the students. The system makes the full power of Coq available to the students, but simultaneously presents the logic problems in a way that is customary in undergraduate logic courses. Both styles of presenting natural deduction proofs (Gentzen-style `tree view' and Fitch-style `box view' are supported. Part of the system is a parser that indicates whether the students used the automation of Coq to solve their problems or that they solved it themselves using only the inference rules of the logic. For these inference rules dedicated tactics for Coq have been developed. The system has already been used in type theory courses and logic undergraduate courses. The ProofWeb system can be tried at http://proofweb.cs.ru.nl/.

  1. Gödel, Truth and Proof

    Czech Academy of Sciences Publication Activity Database

    Peregrin, Jaroslav

    -, č. 82 (2007), s. 1-10 E-ISSN 1742-6596 R&D Projects: GA ČR(CZ) GA401/04/0117 Institutional research plan: CEZ:AV0Z90090514 Keywords : Gödel * incompleteness of arithmetic * proof vs. truth Subject RIV: AA - Philosophy ; Religion http://www.iop.org/EJ/ toc /1742-6596/82/1

  2. The Development of Proofs in Analytical Mathematics for Undergraduate Students

    Science.gov (United States)

    Ali, Maselan; Sufahani, Suliadi; Hasim, Nurnazifa; Saifullah Rusiman, Mohd; Roslan, Rozaini; Mohamad, Mahathir; Khalid, Kamil

    2018-04-01

    Proofs in analytical mathematics are essential parts of mathematics, difficult to learn because its underlying concepts are not visible. This research consists of problems involving logic and proofs. In this study, a short overview was provided on how proofs in analytical mathematics were used by university students. From the results obtained, excellent students obtained better scores compared to average and poor students. The research instruments used in this study consisted of two parts: test and interview. In this way, analysis of students’ actual performances can be obtained. The result of this study showed that the less able students have fragile conceptual and cognitive linkages but the more able students use their strong conceptual linkages to produce effective solutions

  3. Factors and factorizations of graphs proof techniques in factor theory

    CERN Document Server

    Akiyama, Jin

    2011-01-01

    This book chronicles the development of graph factors and factorizations. It pursues a comprehensive approach, addressing most of the important results from hundreds of findings over the last century. One of the main themes is the observation that many theorems can be proved using only a few standard proof techniques. This stands in marked contrast to the seemingly countless, complex proof techniques offered by the extant body of papers and books. In addition to covering the history and development of this area, the book offers conjectures and discusses open problems. It also includes numerous explanatory figures that enable readers to progressively and intuitively understand the most important notions and proofs in the area of factors and factorization.

  4. A simple proof of renormalization group equation in the minimal subtraction scheme

    International Nuclear Information System (INIS)

    Chetyrkin, K.G.

    1989-04-01

    We give a simple combinatorial proof of the renormalization group equation in the minimal subtraction scheme. Being mathematically rigorous, the proof avoids both the notorious complexity of techniques using parametric representations of Feynman diagrams and heuristic arguments of usual ''proofs'' calling up bare fields living in the space-time of complex dimension. It also copes easily with the general case of Green functions of arbitrary number of composite fields. (author). 24 refs

  5. Computer-aided proofs for multiparty computation with active security

    DEFF Research Database (Denmark)

    Haagh, Helene; Karbyshev, Aleksandr; Oechsner, Sabine

    2018-01-01

    Secure multi-party computation (MPC) is a general cryptographic technique that allows distrusting parties to compute a function of their individual inputs, while only revealing the output of the function. It has found applications in areas such as auctioning, email filtering, and secure...... teleconference. Given its importance, it is crucial that the protocols are specified and implemented correctly. In the programming language community it has become good practice to use computer proof assistants to verify correctness proofs. In the field of cryptography, EasyCrypt is the state of the art proof...... public-key encryption, signatures, garbled circuits and differential privacy. Here we show for the first time that it can also be used to prove security of MPC against a malicious adversary. We formalize additive and replicated secret sharing schemes and apply them to Maurer's MPC protocol for secure...

  6. Autonomous intelligent cars: proof that the EPSRC Principles are future-proof

    Science.gov (United States)

    de Cock Buning, Madeleine; de Bruin, Roeland

    2017-07-01

    Principle 2 of the EPSRC's principles of robotics (AISB workshop on Principles of Robotics, 2016) proves to be future proof when applied to the current state of the art of law and technology surrounding autonomous intelligent cars (AICs). Humans, not AICS, are responsible agents. AICs should be designed; operated as far as is practicable to comply with existing laws and fundamental rights and freedoms, including privacy by design. It will show that some legal questions arising from autonomous intelligent driving technology can be answered by the technology itself.

  7. Stable crack growth during over stressing or proof testing of pressure vessels

    International Nuclear Information System (INIS)

    Njo, D.H.

    1985-07-01

    In an earlier study several years ago an attempt has been made by a study group in Switzerland formed by representatives of utilities, manufacturers, inspection agency and the licensing authority to evaluate systematically the advantages and disadvantages of a proof test for a reactor pressure vessel (RPV) taking into account the different aspects involved. In this study, the present day practice in the requirements regarding proof testing in several countries with nuclear power plants were assessed. Using the method of fracture mechanics, taking into account the proof test conditions and material behaviour at hand, qualified quantitative statements were then sought for. One of the important findings of the study was that a sufficiently accurate determination of stable crack growth (SCG) during proof testing is a necessary precondition for a qualified quantitative statement. At that time this requirement could not be met. The aim of the present exercise of collecting available information on SCG was twofold: to get an overview of the present day requirements on pre-service and in-service proof testing of reactor pressure vessels in different countries with NPPs; to collect data on stable crack growth due to over stressing during proof tests to be used in the quantitative assessment, using fracture mechanics methods, and the potential benefit, if any, of proof tests. In the framework of the present study, the originally stipulated aims could not be achieved. It turned out to be a very complex and difficult problem, where various important aspects are little known and could not be assessed without further comprehensive theoretical and experimental investigations

  8. Advanced imaging of the scapholunate ligamentous complex

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, Maryam; Maeseneer, Michel de; Boulet, Cedric; Mey, Johan de [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Radiology, Brussels (Belgium); Staelens, Barbara; Scheerlinck, Thierry [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Orthopaedics and Traumatology, Brussels (Belgium); Overstraeten, Luc van [Hand and Foot Surgery Unit (HFSU), Tournai (Belgium)

    2015-12-15

    The scapholunate joint is one of the most involved in wrist injuries. Its stability depends on primary and secondary stabilisers forming together the scapholunate complex. This ligamentous complex is often evaluated by wrist arthroscopy. To avoid surgery as diagnostic procedure, optimization of MR imaging parameters as use of three-dimensional (3D) sequences with very thin slices and high spatial resolution, is needed to detect lesions of the intrinsic and extrinsic ligaments of the scapholunate complex. The paper reviews the literature on imaging of radial-sided carpal ligaments with advanced computed tomographic arthrography (CTA) and magnetic resonance arthrography (MRA) to evaluate the scapholunate complex. Anatomy and pathology of the ligamentous complex are described and illustrated with CTA, MRA and corresponding arthroscopy. Sprains, mid-substance tears, avulsions and fibrous infiltrations of carpal ligaments could be identified on CTA and MRA images using 3D fat-saturated PD and 3D DESS (dual echo with steady-state precession) sequences with 0.5-mm-thick slices. Imaging signs of scapholunate complex pathology include: discontinuity, nonvisualization, changes in signal intensity, contrast extravasation (MRA), contour irregularity and waviness and periligamentous infiltration by edema, granulation tissue or fibrosis. Based on this preliminary experience, we believe that 3 T MRA using 3D sequences with 0.5-mm-thick slices and multiplanar reconstructions is capable to evaluate the scapholunate complex and could help to reduce the number of diagnostic arthroscopies. (orig.)

  9. Reversal burden of proof on corruption in Indonesia

    OpenAIRE

    Nugroho, Hibnu

    2018-01-01

    Corruption becomes the greatest enemy most countries face including Indonesia. Commitment to eradicate corruption significantly increases yet it would be meaningless if it is not supported by adequate legislation to implement the law effectively. Reversal burden of proof essentially aims to facilitate law enforcers to seek and disclose assets a suspect owns allegedly as corruption crime. The principle of reversal burden of proof was originated from Anglo-Saxon countries and this still applies...

  10. 6 CFR 13.30 - The hearing and burden of proof.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false The hearing and burden of proof. 13.30 Section 13.30 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY PROGRAM FRAUD CIVIL REMEDIES § 13.30 The hearing and burden of proof. (a) The ALJ will conduct a hearing on the record in order...

  11. Changes in fatigue, multiplanar knee laxity, and landing biomechanics during intermittent exercise.

    Science.gov (United States)

    Shultz, Sandra J; Schmitz, Randy J; Cone, John R; Henson, Robert A; Montgomery, Melissa M; Pye, Michele L; Tritsch, Amanda J

    2015-05-01

    Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Descriptive laboratory study. Laboratory and gymnasium. A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee-valgus motion and dorsiflexion and absorbed more energy at the knee (P ≤ .05), whereas men were positioned in greater hip

  12. NMR imaging of degenerative changes of the spine

    International Nuclear Information System (INIS)

    Beyer, H.K.

    1991-01-01

    Computerized tomography and nuclear spin resonance tomography, are today considered excellent ways of demonstrating herniae of intervertebral disks, especially in the lumbal region, at high sensitivity and accuracy. The facility of multiplanar imaging without reconstruction, the clearly greater amount of information by using different pulse sequences, better contrast resolution, and lacking ionizing radiation speak in favour of nuclear spin resonance tomography. Using nulcear spin resonance tomography, in all parts of the spine the excellent demonstration of the epidural space, of the myeloma, of the nerve roots as well as of the surrounding osseous and ligamentous structure is achieved. So, for the diagnosis of discopathies in the region of the cervical spine nuclear spin resonance tomography should be preferred to computerized tomography. In the region of the lumbar spine, however, CT will be of importance in the diagnosis of discopathies for some time. (orig./MG) [de

  13. Navigation concepts for magnetic resonance imaging-guided musculoskeletal interventions.

    Science.gov (United States)

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2011-08-01

    Image-guided musculoskeletal (MSK) interventions are a widely used alternative to open surgical procedures for various pathological findings in different body regions. They traditionally involve one of the established x-ray imaging techniques (radiography, fluoroscopy, computed tomography) or ultrasound scanning. Over the last decades, magnetic resonance imaging (MRI) has evolved into one of the most powerful diagnostic tools for nearly the whole body and has therefore been increasingly considered for interventional guidance as well.The strength of MRI for MSK applications is a combination of well-known general advantages, such as multiplanar and functional imaging capabilities, wide choice of tissue contrasts, and absence of ionizing radiation, as well as a number of MSK-specific factors, for example, the excellent depiction of soft-tissue tumors, nonosteolytic bone changes, and bone marrow lesions. On the downside, the magnetic resonance-compatible equipment needed, restricted space in the magnet, longer imaging times, and the more complex workflow have so far limited the number of MSK procedures under MRI guidance.Navigation solutions are generally a natural extension of any interventional imaging system, in particular, because powerful hardware and software for image processing have become routinely available. They help to identify proper access paths, provide accurate feedback on the instrument positions, facilitate the workflow in an MRI environment, and ultimately contribute to procedural safety and success.The purposes of this work were to describe some basic concepts and devices for MRI guidance of MSK procedures and to discuss technical and clinical achievements and challenges for some selected implementations.

  14. Three-dimensional CT endoscopic images of the larynx. Clinical application of helical CT

    International Nuclear Information System (INIS)

    Yumoto, Eiji; Sanuki, Tetsuji; Yasuhara, Yoshifumi; Ochi, Takashi

    1998-01-01

    Twenty-seven patients with several laryngeal ailments underwent helical computed tomography (CT) on 37 occasions. Ten of these 27 patients suffered from unilateral vocal fold paralysis (UVFP). Three-dimensional (3D) images of the laryngeal lumen viewed from various angles were produced for all sets of CT volumetric data, except for three which contained excessive motion artifacts. The present paper examined whether 3D endoscopic images could offer useful diagnostic and therapeutic information about UVFP. The 3D endoscopic images viewed from the tracheal side and the hemilaryngeal images viewed from the opposite side could delineate the vocal folds, ventricular fold and ventricle three-dimensionally. Atrophy and hypotonic changes to the vocal fold and expansion of the ventricle on the affected side were clearly shown. The 3D endoscopic images accurately showed the phonosurgical effects on the laryngeal structures. The 3D endoscopic images could be produced even when the vocal folds could not be observed with conventional endoscopy due to their overadduction. Multiplanar reconstruction (MPR) images in the coronal plane were reconstructed at a right angle to the glottic axis when the whole larynx was deviated. In addition, coronal MPR images showed a better resolution among the different layers of the vocal fold soft tissue than X-ray tomography. In conclusion, 3D endoscopic images combined with coronal MPR images can provide useful diagnostic an therapeutic information about UVFP, although motion artifacts may occur. (author)

  15. Formal Proofs for Nonlinear Optimization

    Directory of Open Access Journals (Sweden)

    Victor Magron

    2015-01-01

    Full Text Available We present a formally verified global optimization framework. Given a semialgebraic or transcendental function f and a compact semialgebraic domain K, we use the nonlinear maxplus template approximation algorithm to provide a certified lower bound of f over K.This method allows to bound in a modular way some of the constituents of f by suprema of quadratic forms with a well chosen curvature. Thus, we reduce the initial goal to a hierarchy of semialgebraic optimization problems, solved by sums of squares relaxations. Our implementation tool interleaves  semialgebraic approximations with sums of squares witnesses to form certificates. It is interfaced with Coq and thus benefits from the trusted arithmetic available inside the proof assistant. This feature is used to produce, from the certificates, both valid underestimators and lower bounds for each approximated constituent.The application range for such a tool is widespread; for instance Hales' proof of Kepler's conjecture yields thousands of multivariate transcendental inequalities. We illustrate the performance of our formal framework on some of these inequalities as well as on examples from the global optimization literature.

  16. A Short Proof of Klee's Theorem

    OpenAIRE

    Zanazzi, John J.

    2013-01-01

    In 1959, Klee proved that a convex body $K$ is a polyhedron if and only if all of its projections are polygons. In this paper, a new proof of this theorem is given for convex bodies in $\\mathbb{R}^3$.

  17. 47 CFR 1.359 - Proof of official record; authentication of copy.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Proof of official record; authentication of copy. 1.359 Section 1.359 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Hearing Proceedings Evidence § 1.359 Proof of official record; authentication of copy. An official...

  18. A False-name-Proof Double Auction Protocol for Arbitrary Evaluation Values

    Science.gov (United States)

    Sakurai, Yuko; Yokoo, Makoto

    We develop a new false-name-proof double auction protocol called the Generalized Threshold Price Double auction (GTPD) protocol. False-name-proofness generalizes strategy-proofness by incorporating the possibility of false-name bids, e.g., bids submitted using multiple e-mail addresses. An existing protocol called TPD protocol is false-name-proof but can handle only the cases where marginal utilities of each agent always decrease, while our new GTPD protocol can handle arbitrary evaluation values. When marginal utilities can increase, some bids cannot be divided into a single unit (e.g., an all-or-nothing bid). Due to the existence of such indivisible bids, meeting supply/demand becomes difficult. Furthermore, a seller/buyer can submit a false-name-bid by pretending to be a potential buyer/seller to manipulate allocations and payments. In the GTPD protocol, the auctioneer is required to absorb the supply-demand imbalance up to a given upper-bound. Also, the GTPD incorporate a new false-name-proof one-sided auction protocol that is guaranteed to sell/buy a certain number of units. Simulation results show that when the threshold price is set appropriately, this protocol can obtain a good social surplus, and the number of absorbed units is much smaller than the given upper-bound.

  19. Towards a semantic PACS: Using Semantic Web technology to represent imaging data.

    Science.gov (United States)

    Van Soest, Johan; Lustberg, Tim; Grittner, Detlef; Marshall, M Scott; Persoon, Lucas; Nijsten, Bas; Feltens, Peter; Dekker, Andre

    2014-01-01

    The DICOM standard is ubiquitous within medicine. However, improved DICOM semantics would significantly enhance search operations. Furthermore, databases of current PACS systems are not flexible enough for the demands within image analysis research. In this paper, we investigated if we can use Semantic Web technology, to store and represent metadata of DICOM image files, as well as linking additional computational results to image metadata. Therefore, we developed a proof of concept containing two applications: one to store commonly used DICOM metadata in an RDF repository, and one to calculate imaging biomarkers based on DICOM images, and store the biomarker values in an RDF repository. This enabled us to search for all patients with a gross tumor volume calculated to be larger than 50 cc. We have shown that we can successfully store the DICOM metadata in an RDF repository and are refining our proof of concept with regards to volume naming, value representation, and the applications themselves.

  20. Semantics and correctness proofs for programs with partial functions

    International Nuclear Information System (INIS)

    Yakhnis, A.; Yakhnis, V.

    1996-01-01

    This paper presents a portion of the work on specification, design, and implementation of safety-critical systems such as reactor control systems. A natural approach to this problem, once all the requirements are captured, would be to state the requirements formally and then either to prove (preferably via automated tools) that the system conforms to spec (program verification), or to try to simultaneously generate the system and a mathematical proof that the requirements are being met (program derivation). An obstacle to this is frequent presence of partially defined operations within the software and its specifications. Indeed, the usual proofs via first order logic presuppose everywhere defined operations. Recognizing this problem, David Gries, in ''The Science of Programming,'' 1981, introduced the concept of partial functions into the mainstream of program correctness and gave hints how his treatment of partial functions could be formalized. Still, however, existing theorem provers and software verifiers have difficulties in checking software with partial functions, because of absence of uniform first order treatment of partial functions within classical 2-valued logic. Several rigorous mechanisms that took partiality into account were introduced [Wirsing 1990, Breu 1991, VDM 1986, 1990, etc.]. However, they either did not discuss correctness proofs or departed from first order logic. To fill this gap, the authors provide a semantics for software correctness proofs with partial functions within classical 2-valued 1st order logic. They formalize the Gries treatment of partial functions and also cover computations of functions whose argument lists may be only partially available. An example is nuclear reactor control relying on sensors which may fail to deliver sense data. This approach is sufficiently general to cover correctness proofs in various implementation languages

  1. Image quality analysis to reduce dental artifacts in head and neck imaging with dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D.; Werner, M.K.; Thomas, C.; Tsiflikas, I.; Reimann, A.; Claussen, C.D.; Heuschmid, M. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Koitschev, A. [Tuebingen Univ. (Germany). Abt. fuer Hals-Nasen-Ohrenheilkunde

    2009-01-15

    Purpose: Important oropharyngeal structures can be superimposed by metallic artifacts due to dental implants. The aim of this study was to compare the image quality of multiplanar reconstructions and an angulated spiral in dual-source computed tomography (DSCT) of the neck. Materials and Methods: Sixty-two patients were included for neck imaging with DSCT. MPRs from an axial dataset and an additional short spiral parallel to the mouth floor were acquired. Leading anatomical structures were then evaluated with respect to the extent to which they were affected by dental artifacts using a visual scale, ranging from 1 (least artifacts) to 4 (most artifacts). Results: In MPR, 87.1 % of anatomical structures had significant artifacts (3.12 {+-} 0.86), while in angulated slices leading anatomical structures of the oropharynx showed negligible artifacts (1.28 {+-} 0.46). The diagnostic growth due to primarily angulated slices concerning artifact severity was significant (p < 0.01). Conclusion: MPRs are not capable of reducing dental artifacts sufficiently. In patients with dental artifacts overlying the anatomical structures of the oropharynx, an additional short angulated spiral parallel to the floor of the mouth is recommended and should be applied for daily routine. As a result of the static gantry design of DSCT, the use of a flexible head holder is essential. (orig.)

  2. Strategy-Proof Assignment Of Multiple Resources

    DEFF Research Database (Denmark)

    Erlanson, Albin; Szwagrzak, Karol

    2015-01-01

    We examine the strategy-proof allocation of multiple resources; an application is the assignment of packages of tasks, workloads, and compensations among the members of an organization. In the domain of multidimensional single-peaked preferences, we find that any allocation mechanism obtained by ...

  3. Magnetic resonance imaging of the active second stage of labour: Proof of principle

    International Nuclear Information System (INIS)

    Guettler, F.V.; Heinrich, A.; Rump, J.; Bucourt, M. de; Hamm, B.; Teichgraeber, U.K.; Schnackenburg, B.; Bamberg, C.

    2012-01-01

    To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible. Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging. To monitor the birth status during image acquisition, an MR-compatible wireless cardiotocography (CTG) system was built. Single-shot sequence parameters were optimised to compensate motion artefacts during labour. Safety requirements to monitor the birth process under real-time MR imaging were met. High-resolution MR images were acquired immediately before and after delivery. In one patient, TSE single-shot cinematic sequences of the active second stage of labour were obtained. All sequences were adapted to tolerate movement of the mother and infant, as well as residual noise from the CTG. Furthermore, the MR imaging during labour showed only minor image artefacts. CTG-monitored acquisition of MRI series during the active second stage of delivery is feasible. Image quality should allow various further studies to improve models for birth simulation as well as potential investigation of obstructed labour and obstetric complications. (orig.)

  4. 47 CFR 1.254 - Nature of the hearing; burden of proof.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Nature of the hearing; burden of proof. 1.254 Section 1.254 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Hearing Proceedings Hearing and Intermediate Decision § 1.254 Nature of the hearing; burden of proof. Any hearing upon...

  5. Usefulness of three dimensional reconstructive images for thoracic trauma induced fractures

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kyung Hun; Kim, Dong Hun; Kim, Young Sook; Byun, Joo Nam [Chosun University Hospital, Gwangju (Korea, Republic of)

    2006-09-15

    We wanted to evaluate the usefulness of three-dimensional reconstructive images using multidetector computed tomography (MDCT) for thoracic traumatic patients visiting emergency room. 76 patients with fractures of the 105 patients who visited our emergency room with complaints of thoracic trauma were analyzed retrospectively. All the patients had thoracic MDCT performed and the three-dimensional reconstructive images were taken. The fractures were confirmed by axial CT, the clinical information, whole body bone scanning and the multiplanar reformation images. Plain x-ray images were analyzed by the fractured sites in a blind comparison of two radiologists' readings, and then that finding was compared with the axial CT scans and the three-dimensional reconstructive images. The fracture sites were rib (n 68), sternum (n = 14), clavicle (n = 6), scapula (n = 3), spine (n = 5) and combined fractures (n = 14). Plain x-ray and axial CT scans had a correspondency of 0.555 for the rib fractures. Axial CT scans and the three-dimensional reconstructive images had a correspondency of .952. For sternal fractures, those values were 0.692 and 0.928, respectively. The axial CT scans and three-dimensional reconstructive images showed sensitivities of 94% and 91% for rib and other fractures, respectively, and 93% and 100% for sternal fracture, respectively. Three-dimensional reconstructive image had an especially high sensitivity for the diagnosis of sternal fracture. While evaluating thoracic trauma at the emergency room, the three-dimensional reconstructive image was useful to easily diagnose the extent of fracture and it was very sensitive for detecting sternal fracture.

  6. Usefulness of three dimensional reconstructive images for thoracic trauma induced fractures

    International Nuclear Information System (INIS)

    Koh, Kyung Hun; Kim, Dong Hun; Kim, Young Sook; Byun, Joo Nam

    2006-01-01

    We wanted to evaluate the usefulness of three-dimensional reconstructive images using multidetector computed tomography (MDCT) for thoracic traumatic patients visiting emergency room. 76 patients with fractures of the 105 patients who visited our emergency room with complaints of thoracic trauma were analyzed retrospectively. All the patients had thoracic MDCT performed and the three-dimensional reconstructive images were taken. The fractures were confirmed by axial CT, the clinical information, whole body bone scanning and the multiplanar reformation images. Plain x-ray images were analyzed by the fractured sites in a blind comparison of two radiologists' readings, and then that finding was compared with the axial CT scans and the three-dimensional reconstructive images. The fracture sites were rib (n 68), sternum (n = 14), clavicle (n = 6), scapula (n = 3), spine (n = 5) and combined fractures (n = 14). Plain x-ray and axial CT scans had a correspondency of 0.555 for the rib fractures. Axial CT scans and the three-dimensional reconstructive images had a correspondency of .952. For sternal fractures, those values were 0.692 and 0.928, respectively. The axial CT scans and three-dimensional reconstructive images showed sensitivities of 94% and 91% for rib and other fractures, respectively, and 93% and 100% for sternal fracture, respectively. Three-dimensional reconstructive image had an especially high sensitivity for the diagnosis of sternal fracture. While evaluating thoracic trauma at the emergency room, the three-dimensional reconstructive image was useful to easily diagnose the extent of fracture and it was very sensitive for detecting sternal fracture

  7. Goedel, truth and proof

    International Nuclear Information System (INIS)

    Peregrin, Jaroslav

    2007-01-01

    The usual way of interpreting Goedel's (1931) incompleteness result is as showing that there is a gap between truth and provability, i.e. that we can never prove everything that is true. Moreover, this result is supposed to show that there are unprovable truths which we can know to be true. This, so the story goes, shows that we are more than machines that are restricted to acting as proof systems. Hence our minds are 'not mechanical'

  8. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    Energy Technology Data Exchange (ETDEWEB)

    Sun Xiaoli; Liang Changhu [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China); Liu Cheng [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)], E-mail: sdsxl2005@126.com; Liu Shuwei; Deng Kai; He Jingzhen [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)

    2010-02-15

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  9. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    International Nuclear Information System (INIS)

    Sun Xiaoli; Liang Changhu; Liu Cheng; Liu Shuwei; Deng Kai; He Jingzhen

    2010-01-01

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  10. The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing

    International Nuclear Information System (INIS)

    Kang, Ho Duk; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2007-01-01

    To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Sprague-Dawely strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multiplanar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR images revealed similar reformation of the healing mount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based mythologies. MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing

  11. D3D augmented reality imaging system: proof of concept in mammography.

    Science.gov (United States)

    Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene

    2016-01-01

    The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.

  12. Modifying the ECC-based grouping-proof RFID system to increase inpatient medication safety.

    Science.gov (United States)

    Ko, Wen-Tsai; Chiou, Shin-Yan; Lu, Erl-Huei; Chang, Henry Ker-Chang

    2014-09-01

    RFID technology is increasingly used in applications that require tracking, identification, and authentication. It attaches RFID-readable tags to objects for identification and execution of specific RFID-enabled applications. Recently, research has focused on the use of grouping-proofs for preserving privacy in RFID applications, wherein a proof of two or more tags must be simultaneously scanned. In 2010, a privacy-preserving grouping proof protocol for RFID based on ECC in public-key cryptosystem was proposed but was shown to be vulnerable to tracking attacks. A proposed enhancement protocol was also shown to have defects which prevented proper execution. In 2012, Lin et al. proposed a more efficient RFID ECC-based grouping proof protocol to promote inpatient medication safety. However, we found this protocol is also vulnerable to tracking and impersonation attacks. We then propose a secure privacy-preserving RFID grouping proof protocol for inpatient medication safety and demonstrate its resistance to such attacks.

  13. A 3-axis force balanced accelerometer using a single proof-mass

    Energy Technology Data Exchange (ETDEWEB)

    Lemkin, M.A.; Boser, B.E.; Auslander, D. [Univ. of California, Berkeley, CA (United States); Smith, J. [Sandia National Lab., Albuquerque, NM (United States)

    1997-04-01

    This paper presents a new method for wideband force balancing a proof-mass in multiple axes simultaneously. Capacitive position sense and force feedback are accomplished using the same air-gap capacitors through time multiplexing. Proof of concept is experimentally demonstrated with a single-mass monolithic surface micromachined 3-axis accelerometer.

  14. Proofs of the Cantor-Bernstein theorem a mathematical excursion

    CERN Document Server

    Hinkis, Arie

    2013-01-01

    This book offers an excursion through the developmental area of research mathematics. It presents some 40 papers, published between the 1870s and the 1970s, on proofs of the Cantor-Bernstein theorem and the related Bernstein division theorem. While the emphasis is placed on providing accurate proofs, similar to the originals, the discussion is broadened to include aspects that pertain to the methodology of the development of mathematics and to the philosophy of mathematics. Works of prominent mathematicians and logicians are reviewed, including Cantor, Dedekind, Schröder, Bernstein, Borel, Zermelo, Poincaré, Russell, Peano, the Königs, Hausdorff, Sierpinski, Tarski, Banach, Brouwer and several others mainly of the Polish and the Dutch schools. In its attempt to present a diachronic narrative of one mathematical topic, the book resembles Lakatos’ celebrated book Proofs and Refutations. Indeed, some of the observations made by Lakatos are corroborated herein. The analogy between the two books is clearly an...

  15. Equihash: Asymmetric Proof-of-Work Based on the Generalized Birthday Problem

    Directory of Open Access Journals (Sweden)

    Alex Biryukov

    2017-04-01

    Full Text Available Proof-of-work is a central concept in modern cryptocurrencies and denial-ofservice protection tools, but the requirement for fast verification so far has made it an easy prey for GPU-, ASIC-, and botnet-equipped users. The attempts to rely on memory-intensive computations in order to remedy the disparity between architectures have resulted in slow or broken schemes. In this paper we solve this open problem and show how to construct an asymmetric proof-of-work (PoW based on a computationally-hard problem, which requires a great deal of memory to generate a proof (called a ”memory-hardness” feature but is instant to verify. Our primary proposal, Equihash, is a PoW based on the generalized birthday problem and enhanced Wagner’s algorithm for it. We introduce the new technique of algorithm binding to prevent cost amortization and demonstrate that possible parallel implementations are constrained by memory bandwidth. Our scheme has tunable and steep time-space tradeoffs, which impose large computational penalties if less memory is used. Our solution is practical and ready to deploy: a reference implementation of a proof-of-work requiring 700 MB of RAM runs in 15 seconds on a 2.1 GHz CPU, increases the computations by a factor of 1000 if memory is halved, and presents a proof of just 120 bytes long.

  16. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  17. Pythagoras on the rocks. A proof with bricks

    Directory of Open Access Journals (Sweden)

    Michele Cagol

    2016-04-01

    Full Text Available In this short paper a practical and simple proof of the Pythagorean theorem is proposed. It uses colourful interlocking plastic bricks with two shapes: a cube that measures two centimeters on each side and a right prism where the base is a right-angled isosceles triangle and the two equal rectangular faces are the same as those of the cubic brick. The proof is designed for primary school children (but also for preschool children and begins by telling the legend of Pythagoras, who discovered his theorem by looking at the floor tile pattern of Polycrates’ palace. This proof takes into account only right-angled isosceles triangle but it is possible to show the validity of Pythagorean theorem for all right-angled triangles by building a simple proof by rearrangement. Pitagora on the rocks. Una dimostrazione con i mattonciniIn questo breve contributo viene proposta una semplice dimostrazione pratica del teorema di Pitagora, utilizzando mattoncini a incastro di plastica colorata di due forme: un cubo di due centimetri per lato e un prisma retto la cui base è un triangolo isoscele rettangolo e nel quale le due facce equivalenti sono uguali a quelle del mattoncino cubico. La dimostrazione è rivolta a bambini della scuola primaria (ma, eventualmente, anche in età prescolare e prende le mosse dalla leggenda secondo la quale Pitagora avrebbe scoperto il suo teorema mentre stava osservando il pavimento piastrellato del palazzo di Policrate, tiranno di Samo. Da questa dimostrazione – che prende in considerazione solo triangoli rettangoli isosceli – è poi possibile passare a una dimostrazione del teorema di Pitagora per tutti i triangoli rettangoli.

  18. Opportunities to Learn Reasoning and Proof in High School Mathematics Textbooks

    Science.gov (United States)

    Thompson, Denisse R.; Senk, Sharon L.; Johnson, Gwendolyn J.

    2012-01-01

    The nature and extent of reasoning and proof in the written (i.e., intended) curriculum of 20 contemporary high school mathematics textbooks were explored. Both the narrative and exercise sets in lessons dealing with the topics of exponents, logarithms, and polynomials were examined. The extent of proof-related reasoning varied by topic and…

  19. Proof and Proving: Logic, Impasses, and the Relationship to Problem Solving

    Science.gov (United States)

    Savic, Milos

    2012-01-01

    Becoming a skillful prover is critical for success in advanced undergraduate and graduate mathematics courses. In this dissertation, I report my investigations of proof and the proving process in three separate studies. In the first study, I examined the amount of logic used in student-constructed proofs to help in the design of…

  20. A new proof-of-principle contraband detection system

    Energy Technology Data Exchange (ETDEWEB)

    Sredniawski, J.J.; Debiak, T.; Kamykowski, E.; Rathke, J. [Northrop Grumman Corp., Bethpage, NY (United States). Advanced Technology and Development Center; Schmor, P.; Altman, A.; Rogers, J.; Boyd, J. [British Columbia Univ., Vancouver, BC (Canada). TRIUMF Facility; Brondo, J. [Scientific Innovations, Inc., East Hampton, NY (United States)

    1995-12-01

    A new concept for a CDS has been developed under a Phase I ARPA funded program; it uses gamma resonance absorption (GRA) to detect certain illegal drugs that may be transported in man-portable containers. A high detection probability for heroin and cocaine is possible with a device that is also searching for explosives. Elemental detection of both N and Cl is utilized, and with tomography, a 3D density image of the elements is generated. Total density image is also developed. These two together may be used with considerable confidence in determining if heroin or cocaine is present in the interrogated containers in a small quantity (1 kg). The CDS employs a high current ({ge}10 mA) DC accelerator that produces a beam of 1.75 or 1.89 MeV protons. These protons impact a target with coatings of {sup 13}C and {sup 34}S. Depending on the coating, the resultant resonant gamma rays are preferentially absorbed in either {sup 14}N or {sup 35}Cl. The resonant gammas come off the target in a conical fan at 80.7{degree} for N and 82{degree} for Cl; a common array of segmented BGO detectors is used over an arc of 53{degree} to provide input to an imaging subsystem. The tomography makes use of rotation and vertical translation of a baggage carousel holding typically 18 average sized bags for batch processing of the contents. The single proton accelerator and target can supply multiple detection stations with the appropriate gammas, a feature that may lead to very high throughput potential approaching 2000 bags/hr. Each detection station can operate somewhat independently from the others. This paper presents the overall requirements, design, operating principles, and characteristics of the CDS proof-of-principle device developed in the Phase I program.

  1. Coqoon - An IDE for Interactive Proof Development in Coq

    DEFF Research Database (Denmark)

    Faithfull, Alexander; Bengtson, Jesper; Tassi, Enrico

    2016-01-01

    User interfaces for interactive proof assistants have always lagged behind those for mainstream programming languages. Whereas integrated development environments—IDEs—have support for features like project management, version control, dependency analysis and incremental project compilation, “IDE...... these projects using the Eclipse common build system. Coqoon takes advantage of the latest features of Coq, including asynchronous and parallel processing of proofs, and—when used together with a third-party OCaml extension for Eclipse—can even be used to work on large developments containing Coq plugins....

  2. A proof of the conjecture on the twin primes

    Energy Technology Data Exchange (ETDEWEB)

    Zuo-ling, Zhou [Department of Lingnan college, Sun Yat-sen University GuangZhou, GuangDong, 510275 (China)

    2016-06-08

    In this short note, we have proved the conjecture on twin primes using some thoughts of the set theory. Firstly, using the original sieve method and a new notation(concept)introduced by myself, the conjecture on twin primes is summed up as an elementary successive limit, afterwards we form a subsequence of positive integers,and using it,we prove that the successive limits are commutative and complete the proof of the conjecture on twin primes We also give a more straightforward proof of the conjecture.

  3. Exploring mathematics problem-solving and proof

    CERN Document Server

    Grieser, Daniel

    2018-01-01

    Have you ever faced a mathematical problem and had no idea how to approach it? Or perhaps you had an idea but got stuck halfway through? This book guides you in developing your creativity, as it takes you on a voyage of discovery into mathematics. Readers will not only learn strategies for solving problems and logical reasoning, but they will also learn about the importance of proofs and various proof techniques. Other topics covered include recursion, mathematical induction, graphs, counting, elementary number theory, and the pigeonhole, extremal and invariance principles. Designed to help students make the transition from secondary school to university level, this book provides readers with a refreshing look at mathematics and deep insights into universal principles that are valuable far beyond the scope of this book. Aimed especially at undergraduate and secondary school students as well as teachers, this book will appeal to anyone interested in mathematics. Only basic secondary school mathematics is requi...

  4. The contribution of magnetic resonance imaging of the larynx compared with that of computed tomography in the pretreatment assessment of laryngeal cancers based on a series of ninety operated cases

    International Nuclear Information System (INIS)

    Giron, J.; Joffre, P.; Serres-Cousine, O.; Castan, P.; Senac, J.P.

    1990-01-01

    The authors report a prospective and comparative study of the pre-operative staging of 90 laryngeal carcinomas by CT and MRI, with blind analysis of each examination. The radio-anatomic correlations and the inter-method correlations (CT versus MRI) are reported. According to the authors MRI seems to be the method of choice because of its capabilities in soft tissues differentiation and because of its multiplanar representation. The motion artefacts are resolved by the fast imaging technique and the spatial resolution is optimized by special surface coils [fr

  5. A short list color proof of Grötzsch's theorem

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2003-01-01

    We give a short proof of the result that every planar graph of girth 5 is 3-choosable and hence also of Grotzsch's theorem saying that every planar triangle-free graph is 3-colorable.......We give a short proof of the result that every planar graph of girth 5 is 3-choosable and hence also of Grotzsch's theorem saying that every planar triangle-free graph is 3-colorable....

  6. D3D augmented reality imaging system: proof of concept in mammography

    Directory of Open Access Journals (Sweden)

    Douglas DB

    2016-08-01

    Full Text Available David B Douglas,1 Emanuel F Petricoin,2 Lance Liotta,2 Eugene Wilson3 1Department of Radiology, Stanford University, Palo Alto, CA, 2Center for Applied Proteomics and Molecular Medicine, George Mason University, Manassas, VA, 3Department of Radiology, Fort Benning, Columbus, GA, USA Purpose: The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called “depth 3-dimensional (D3D augmented reality”. Materials and methods: A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. Results: The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. Conclusion: The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice. Keywords: augmented reality, 3D medical imaging, radiology, depth perception

  7. Parity proofs of the Kochen–Specker theorem based on the Lie algebra E8

    International Nuclear Information System (INIS)

    Waegell, Mordecai; Aravind, P K

    2015-01-01

    The 240 root vectors of the Lie algebra E8 lead to a system of 120 rays in a real eight-dimensional Hilbert space that contains a large number of parity proofs of the Kochen–Specker (KS) theorem. After introducing the rays in a triacontagonal representation due to Coxeter, we present their KS diagram in the form of a ‘basis table’ showing all 2025 bases (i.e., sets of eight mutually orthogonal rays) formed by the rays. Only a few of the bases are actually listed, but simple rules are given, based on the symmetries of E8, for obtaining all the other bases from the ones shown. The basis table is an object of great interest because all the parity proofs of E8 can be exhibited as subsets of it. We show how the triacontagonal representation of E8 facilitates the identification of substructures that are more easily searched for their parity proofs. We have found hundreds of different types of parity proofs, ranging from 9 bases (or contexts) at the low end to 35 bases at the high end, and involving projectors of various ranks and multiplicities. After giving an overview of the proofs we found, we present a few concrete examples of the proofs that illustrate both their generic features as well as some of their more unusual properties. In particular, we present a proof involving 34 rays and 9 bases that appears to provide the most compact proof of the KS theorem found to date in eight-dimensions. (paper)

  8. Logic Reduced To Bare (Proof-Theoretical) Bones

    Czech Academy of Sciences Publication Activity Database

    Peregrin, Jaroslav

    2015-01-01

    Roč. 24, č. 2 (2015), s. 193-209 ISSN 0925-8531 Institutional support: RVO:67985955 Keywords : inference * incompatibility * proof theory * intuitionistic logic Subject RIV: AA - Philosophy ; Religion Impact factor: 0.450, year: 2015

  9. CT imaging and histopathological features of renal epithelioid angiomyolipomas

    International Nuclear Information System (INIS)

    Cui, L.; Zhang, J.-G.; Hu, X.-Y.; Fang, X.-M.; Lerner, A.; Yao, X.-J.; Zhu, Z.-M.

    2012-01-01

    Aim: To describe computed tomography (CT) imaging and histopathological manifestations of renal epithelioid angiomyolipomas (EAMLs) for better understanding and cognition in the diagnosis of this new category of renal tumours. Materials and methods: Clinical data and CT images from 10 cases of EAML were retrospectively analysed. All patients underwent CT with and without contrast medium administration, with multiplanar reconstruction (MPR) when needed. Results: Plain CT manifestations of EAMLs were a higher density of mass (10–25 HU) than renal parenchyma, bulging contour of the involved kidney, absence of fat, distinct edges without a lobulate appearance. Contrast-enhanced CT features were markedly heterogeneous enhancement (from rapid wash-in to slow wash-out), large tumour size without lobular appearance, complete capsule with distinct margins and frequent mild necrotic areas. Histopathological features were epithelioid cells with eosinophilic cytoplasm, large and deeply stained nuclei, and dense arrangement of tumour cells with patchy necrosis; diffuse sheets of epithelioid cells were positive for HMB-45 (melanoma-associated antigen) and negative for epithelial membrane antigen (EMA) staining. Conclusion: Multiple specific CT features correlated well with the histopathology and may play an important role in the primary diagnosis of EAMLs.

  10. Inclusion of brain in FDG PET/CT scanning techniques in cancer patients: Does it obviate the need for dedicated brain imaging?

    International Nuclear Information System (INIS)

    Purandare, Nilendu C.

    2011-01-01

    Metastases to the brain can affect about 10-20% cancer patients. Rising incidence of brain metastases in recent years is related to improved survival rates as a result of advances in cancer therapy and development of more sensitive diagnostic imaging techniques. In patients with extracranial malignancies detection of brain metastases is very important in deciding further diagnostic procedures, planning therapeutic strategies and also to ascertain prognosis. Computerized tomography (CT) and magnetic resonance imaging (MRI) are the modalities which have been traditionally used to assess metastatic disease to the central nervous system. It is generally accepted that MRI (contrast enhanced) is superior to CT scan (contrast enhanced) in the diagnosis of brain metastases. An inherently better soft tissue contrast resolution, stronger contrast enhancement, lack of bone artifacts and partial volume effects and direct multiplanar imaging enables MRI to pick up smaller sized as well as more number of metastases than a CT scan

  11. Study of Solid State Drives performance in PROOF distributed analysis system

    Science.gov (United States)

    Panitkin, S. Y.; Ernst, M.; Petkus, R.; Rind, O.; Wenaus, T.

    2010-04-01

    Solid State Drives (SSD) is a promising storage technology for High Energy Physics parallel analysis farms. Its combination of low random access time and relatively high read speed is very well suited for situations where multiple jobs concurrently access data located on the same drive. It also has lower energy consumption and higher vibration tolerance than Hard Disk Drive (HDD) which makes it an attractive choice in many applications raging from personal laptops to large analysis farms. The Parallel ROOT Facility - PROOF is a distributed analysis system which allows to exploit inherent event level parallelism of high energy physics data. PROOF is especially efficient together with distributed local storage systems like Xrootd, when data are distributed over computing nodes. In such an architecture the local disk subsystem I/O performance becomes a critical factor, especially when computing nodes use multi-core CPUs. We will discuss our experience with SSDs in PROOF environment. We will compare performance of HDD with SSD in I/O intensive analysis scenarios. In particular we will discuss PROOF system performance scaling with a number of simultaneously running analysis jobs.

  12. A proof of the conformal collider bounds

    Energy Technology Data Exchange (ETDEWEB)

    Hofman, Diego M. [Institute for Theoretical Physics, University of Amsterdam, Science Park 904, Postbus 94485, 1090 GL, Amsterdam (Netherlands); Li, Daliang [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States); Meltzer, David [Department of Physics, Yale University, New Haven, CT 06511 (United States); Poland, David [Department of Physics, Yale University, New Haven, CT 06511 (United States); School of Natural Sciences, Institute for Advanced Study, Princeton, NJ 08540 (United States); Rejon-Barrera, Fernando [Institute for Theoretical Physics, University of Amsterdam, Science Park 904, Postbus 94485, 1090 GL, Amsterdam (Netherlands)

    2016-06-20

    In this paper, we prove that the “conformal collider bounds” originally proposed in http://dx.doi.org/10.1088/1126-6708/2008/05/012 hold for any unitary parity-preserving conformal field theory (CFT) with a unique stress tensor in dimensions d≥3. In particular this implies that the ratio of central charges for a unitary 4d CFT lies in the interval (31/18)≥(a/c)≥(1/3). For superconformal theories this is further reduced to (3/2)≥(a/c)≥(1/2). The proof relies only on CFT first principles — in particular, bootstrap methods — and thus constitutes the first complete field theory proof of these bounds. We further elaborate on similar bounds for non-conserved currents and relate them to results obtained recently from deep inelastic scattering.

  13. A Proof of Concept to Bridge the Gap between Mass Spectrometry Imaging, Protein Identification and Relative Quantitation: MSI~LC-MS/MS-LF

    Directory of Open Access Journals (Sweden)

    Laëtitia Théron

    2016-10-01

    Full Text Available Mass spectrometry imaging (MSI is a powerful tool to visualize the spatial distribution of molecules on a tissue section. The main limitation of MALDI-MSI of proteins is the lack of direct identification. Therefore, this study focuses on a MSI~LC-MS/MS-LF workflow to link the results from MALDI-MSI with potential peak identification and label-free quantitation, using only one tissue section. At first, we studied the impact of matrix deposition and laser ablation on protein extraction from the tissue section. Then, we did a back-correlation of the m/z of the proteins detected by MALDI-MSI to those identified by label-free quantitation. This allowed us to compare the label-free quantitation of proteins obtained in LC-MS/MS with the peak intensities observed in MALDI-MSI. We managed to link identification to nine peaks observed by MALDI-MSI. The results showed that the MSI~LC-MS/MS-LF workflow (i allowed us to study a representative muscle proteome compared to a classical bottom-up workflow; and (ii was sparsely impacted by matrix deposition and laser ablation. This workflow, performed as a proof-of-concept, suggests that a single tissue section can be used to perform MALDI-MSI and protein extraction, identification, and relative quantitation.

  14. Decorated proofs for computational effects: States

    Directory of Open Access Journals (Sweden)

    Jean-Guillaume Dumas

    2012-08-01

    Full Text Available The syntax of an imperative language does not mention explicitly the state, while its denotational semantics has to mention it. In this paper we show that the equational proofs about an imperative language may hide the state, in the same way as the syntax does.

  15. Hash3: Proofs, Analysis and Implementation

    DEFF Research Database (Denmark)

    Gauravaram, Praveen

    2009-01-01

    This report outlines the talks presented at the winter school on Hash3: Proofs, Analysis, and Implementation, ECRYPT II Event on Hash Functions. In general, speakers may not write everything what they talk on the slides. So, this report also outlines such findings following the understanding of t...

  16. Retinal fundus imaging with a plenoptic sensor

    Science.gov (United States)

    Thurin, Brice; Bloch, Edward; Nousias, Sotiris; Ourselin, Sebastien; Keane, Pearse; Bergeles, Christos

    2018-02-01

    Vitreoretinal surgery is moving towards 3D visualization of the surgical field. This require acquisition system capable of recording such 3D information. We propose a proof of concept imaging system based on a light-field camera where an array of micro-lenses is placed in front of a conventional sensor. With a single snapshot, a stack of images focused at different depth are produced on the fly, which provides enhanced depth perception for the surgeon. Difficulty in depth localization of features and frequent focus-change during surgery are making current vitreoretinal heads-up surgical imaging systems cumbersome to use. To improve the depth perception and eliminate the need to manually refocus on the instruments during the surgery, we designed and implemented a proof-of-concept ophthalmoscope equipped with a commercial light-field camera. The sensor of our camera is composed of an array of micro-lenses which are projecting an array of overlapped micro-images. We show that with a single light-field snapshot we can digitally refocus between the retina and a tool located in front of the retina or display an extended depth-of-field image where everything is in focus. The design and system performances of the plenoptic fundus camera are detailed. We will conclude by showing in vivo data recorded with our device.

  17. A Simple Proof of the Theorem Concerning Optimality in a One-Dimensional Ergodic Control Problem

    International Nuclear Information System (INIS)

    Fujita, Y.

    2000-01-01

    We give a simple proof of the theorem concerning optimality in a one-dimensional ergodic control problem. We characterize the optimal control in the class of all Markov controls. Our proof is probabilistic and does not need to solve the corresponding Bellman equation. This simplifies the proof

  18. Circular, explosion-proof lamp provides uniform illumination

    Science.gov (United States)

    1966-01-01

    Circular explosion-proof fluorescent lamp is fitted around a TV camera lens to provide shadowless illumination with a low radiant heat flux. The lamp is mounted in a transparent acrylic housing sealed with clear silicone rubber.

  19. Raman imaging using fixed bandpass filter

    Science.gov (United States)

    Landström, L.; Kullander, F.; Lundén, H.; Wästerby, P.

    2017-05-01

    By using fixed narrow band pass optical filtering and scanning the laser excitation wavelength, hyperspectral Raman imaging could be achieved. Experimental, proof-of-principle results from the Chemical Warfare Agent (CWA) tabun (GA) as well as the common CWA simulant tributyl phosphate (TBP) on different surfaces/substrates are presented and discussed.

  20. Proof systems for Moss’ coalgebraic logic

    NARCIS (Netherlands)

    Bílková, M.; Palmigiano, A.; Venema, Y.

    2014-01-01

    We study Gentzen-style proof theory of the finitary version of the coalgebraic logic introduced by L. Moss. The logic captures the behaviour of coalgebras for a large class of set functors. The syntax of the logic, defined uniformly with respect to a finitary coalgebraic type functor T , uses a

  1. Short proofs for the determinant identities

    Czech Academy of Sciences Publication Activity Database

    Hrubeš, Pavel; Tzameret, I.

    2015-01-01

    Roč. 44, č. 2 (2015), s. 340-383 ISSN 0097-5397 EU Projects: European Commission(XE) 339691 - FEALORA Program:FP7 Institutional support: RVO:67985840 Keywords : proof complexity * arithmetic circuits Subject RIV: BA - General Mathematics Impact factor: 0.841, year: 2015 http://epubs.siam.org/doi/abs/10.1137/130917788

  2. A Lightweight RFID Grouping-Proof Protocol Based on Parallel Mode and DHCP Mechanism

    Directory of Open Access Journals (Sweden)

    Zhicai Shi

    2017-07-01

    Full Text Available A Radio Frequency Identification (RFID grouping-proof protocol is to generate an evidence of the simultaneous existence of a group of tags and it has been applied to many different fields. For current grouping-proof protocols, there still exist some flaws such as low grouping-proof efficiency, being vulnerable to trace attack and information leakage. To improve the secure performance and efficiency, we propose a lightweight RFID grouping-proof protocol based on parallel mode and DHCP (Dynamic Host Configuration Protocol mechanism. Our protocol involves multiple readers and multiple tag groups. During the grouping-proof period, one reader and one tag group are chosen by the verifier by means of DHCP mechanism. When only a part of the tags of the chosen group exist, the protocol can also give the evidence of their co-existence. Our protocol utilizes parallel communication mode between reader and tags so as to ensure its grouping-proof efficiency. It only uses Hash function to complete the mutual authentication among verifier, readers and tags. It can preserve the privacy of the RFID system and resist the attacks such as eavesdropping, replay, trace and impersonation. Therefore the protocol is secure, flexible and efficient. It only uses some lightweight operations such as Hash function and a pseudorandom number generator. Therefore it is very suitable to some low-cost RFID systems.

  3. A nonperturbative proof of Dijkgraaf-Vafa conjecture

    International Nuclear Information System (INIS)

    Terashima, Seiji

    2016-01-01

    In this note we exactly compute the gaugino condensation of an arbitrary four dimensional N=1 supersymmetric gauge theory in confining phase, using the localization technique. This result gives a nonperturbative proof of the Dijkgraaf-Vafa conjecture.

  4. Ergodicity, Maximum Entropy Production, and Steepest Entropy Ascent in the Proofs of Onsager's Reciprocal Relations

    Science.gov (United States)

    Benfenati, Francesco; Beretta, Gian Paolo

    2018-04-01

    We show that to prove the Onsager relations using the microscopic time reversibility one necessarily has to make an ergodic hypothesis, or a hypothesis closely linked to that. This is true in all the proofs of the Onsager relations in the literature: from the original proof by Onsager, to more advanced proofs in the context of linear response theory and the theory of Markov processes, to the proof in the context of the kinetic theory of gases. The only three proofs that do not require any kind of ergodic hypothesis are based on additional hypotheses on the macroscopic evolution: Ziegler's maximum entropy production principle (MEPP), the principle of time reversal invariance of the entropy production, or the steepest entropy ascent principle (SEAP).

  5. Prevention of Crime and the Optimal Standard of Proof in Criminal Law

    DEFF Research Database (Denmark)

    Lando, Henrik

    2003-01-01

    The standard of proof in criminal law a®ects retributive justice throughthe number of wrong convictions and wrong acquittals. It also a®ects thelevel of crime, since a higher standard of proof implies less deterrence andless incapacitation. This article derives an expression for the optimal...

  6. Perfect imaging without negative refraction

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom)], E-mail: ulf@st-andrews.ac.uk

    2009-09-15

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional (2D) integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing may also find applications outside of optics, in acoustics, fluid mechanics or quantum physics, wherever waves obey the 2D Helmholtz equation.

  7. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    Science.gov (United States)

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These

  8. The explosion-proof container, satisfying the IAEA norms on safety

    International Nuclear Information System (INIS)

    Syrunin, M.A.; Fedorenko, A.G.; Ivanov, A.G.; Abakumov, A.I.; Nizovtsev, P.N.; Loginov, P.G.; Smolyakov, A.A.; Solov'ev, V.P.

    1998-01-01

    Safety of radioactive materials (RM) transportation is under strict control of the international norms of IAEA, aimed to ensure non-proliferation of hazardous materials in the environments. At the same time the nuclear countries use much more dangerous transportations of two types of hazardous materials. Probability of emergency explosion of high explosives (HE) during transportation and storage of such constructions is not equal to zero. HE explosion can be caused by: 1)excess of mechanical effects, allowable by the norms, on an explosive 2)lightening or fire 3)terrorist attack 4)radio controlled or time controlled mechanism in case of the terrorist device. It is obvious that an accident with explosion HE element of the nuclear weapon in an usual container, which meets the IAEA norms, but is not explosion-proof, will result in its destruction, RM dispersal, and inadmissible pollution of the environments. Therefore, it is urgent need for development of the container, which is able to withstand explosion of HE, placed in it, and to confine released RM inside of it. The experimental prototype of the load-bearing shell of the explosion-proof container (EC) can be the successfully tested spherical steel - glass plastic shell, having high-strength throats and lids. Having weight of 45-50 kg it is able to withstand internal explosion with energy more than 1.4 kg of the TNT equivalent. To preserve the explosion-proofness property in the abnormal environments during transportation, the explosion-proof container should be placed in the protective supporting transport device or the transport container (TC), consisting of the external thin-walled steel shell and the damping heat-proof layer from heat-resistant foam plastic. To justify the design parameters of such container, the tests for development and revision of the numerical model parameters were carried out. With use of this model the calculations were performed to calculate loads and the container response to 1

  9. Proof of patient information: Analysis of 201 judicial decisions.

    Science.gov (United States)

    Dugleux, E; Rached, H; Rougé-Maillart, C

    2018-05-01

    The ruling by the French Court of Cassation dated February 25, 1997 obliged doctors to provide proof of the information given to patients, reversing more than half a century of case law. In October 1997, it was specified that such evidence could be provided by "all means", including presumption. No hierarchy in respect of means of proof has been defined by case law or legislation. The present study analyzed judicial decisions with a view to determining the means of proof liable to carry the most weight in a suit for failure to provide due patient information. A retrospective qualitative study was conducted for the period from January 2010 to December 2015, by a search on the LexisNexis ® JurisClasseur website. Two hundred and one judicial decisions relating to failure to provide due patient information were selected and analyzed to study the characteristics of the practitioners involved, the content of the information at issue and the means of proof provided. The resulting cohort of practitioners was compared with the medical demographic atlas of the French Order of Medicine, considered as exhaustive. Two hundred and one practitioners were investigated for failure to provide information: 45 medical practitioners (22±3%), and 156 surgeons (78±3%) including 45 orthopedic surgeons (29±3.6% of surgeons). Hundred and ninety-three were private sector (96±1.3%) and 8 public sector (4±1.3%). Hundred and one surgeons (65±3.8% of surgeons), and 26 medical practitioners (58±7.4%) were convicted. Twenty-five of the 45 orthopedic surgeons were convicted (55±7.5%). There was no significant difference in conviction rates between surgeons and medical practitioners: odds ratio, 1.339916; 95% CI [0.6393982; 2.7753764] (Chi 2 test: p=0.49). Ninety-two practitioners based their defense on a single means of proof, and 74 of these were convicted (80±4.2%). Forty practitioners based their defense on several means of proof, and 16 of these were convicted (40±7.8%). There was

  10. 77 FR 15457 - Pricing for the 2012 American Eagle Silver Proof Coin

    Science.gov (United States)

    2012-03-15

    ... DEPARTMENT OF THE TREASURY United States Mint Pricing for the 2012 American Eagle Silver Proof Coin AGENCY: United States Mint, Department of the Treasury. ACTION: Notice. SUMMARY: The United States Mint is announcing the price of the 2012 American Eagle Silver Proof Coin. The coins will be offered...

  11. 76 FR 53717 - Pricing for the 2011 American Eagle Silver Proof Coin

    Science.gov (United States)

    2011-08-29

    ... DEPARTMENT OF THE TREASURY United States Mint Pricing for the 2011 American Eagle Silver Proof Coin AGENCY: United States Mint, Department of the Treasury. ACTION: Notice. SUMMARY: The United States Mint is announcing the re-pricing of the 2011 American Eagle Silver Proof Coin. The price of the coins...

  12. 76 FR 33026 - Pricing for the 2011 American Eagle Silver Proof Coin

    Science.gov (United States)

    2011-06-07

    ... DEPARTMENT OF THE TREASURY United States Mint Pricing for the 2011 American Eagle Silver Proof Coin AGENCY: United States Mint, Department of the Treasury. ACTION: Notice. SUMMARY: The United States Mint is announcing the price of the 2011 American Eagle Silver Proof Coin. The coin will be offered for...

  13. Genitourinary MR: Kidneys and adrenal glands

    International Nuclear Information System (INIS)

    Krestin, G.P.

    1999-01-01

    Due to its high tissue contrast and multiplanar imaging capabilites, MRI provides a detailed display of renal and adrenal anatomy. Recent technical developments overcoming the problem of respiration induced motion artifacts and the use of paramagnetic contrast agents have further improved the performance of MRI which has now evolved as an alternative or complementary imaging modality to ultrasound, excretory urography and computed tomography. Dynamic contrast-enhanced studies will usually allow to detect even small enhancing solid areas within the cyst wall. Use of a fast (turbo) spoiled gradient echo sequence allows for assessment of contrast enhancement dynamics in renal and adrenal masses. For tumor staging, the multiplanar imaging capabilities of MRI are advantageous. Perinephric extent is best detected using opposed-phase GRE images resulting in an artifical accentuation of renal contours. Extension into venous structures is best diagnosed by using a GRE sequence allowing for distinction between flowing blood and tumor thrombus. Noninvasive differentiation of adrenal lesions can be performed with an unprecedented accuracy using chemical-shift imaging. (orig.)

  14. Validation techniques for object-oriented proof outlines

    NARCIS (Netherlands)

    Pierik, C.

    2006-01-01

    This thesis presents a proof outline logic for a simple object-oriented programming language. The language has all object-oriented features of popular programming languages like Java and C#. In particular, it supports inheritance, field shadowing, aliasing, dynamic object creation, subtype

  15. Proof of the fundamental BCJ relations for QCD amplitudes

    International Nuclear Information System (INIS)

    Cruz, Leonardo de la; Kniss, Alexander; Weinzierl, Stefan

    2015-01-01

    The fundamental BCJ-relation is a linear relation between primitive tree amplitudes with different cyclic orderings. The cyclic orderings differ by the insertion place of one gluon. The coefficients of the fundamental BCJ-relation are linear in the Lorentz invariants 2p_ip_j. The BCJ-relations are well established for pure gluonic amplitudes as well as for amplitudes in N=4 super-Yang-Mills theory. Recently, it has been conjectured that the BCJ-relations hold also for QCD amplitudes. In this paper we give a proof of this conjecture. The proof is valid for massless and massive quarks.

  16. Proof complexity of intuitionistic implicational formulas

    Czech Academy of Sciences Publication Activity Database

    Jeřábek, Emil

    2017-01-01

    Roč. 168, č. 1 (2017), s. 150-190 ISSN 0168-0072 EU Projects: European Commission(XE) 339691 - FEALORA Institutional support: RVO:67985840 Keywords : proof complexity * intuitionistic logic * implicational fragment Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.647, year: 2016 http://www.sciencedirect.com/science/article/pii/S0168007216301154

  17. A Foundational Proof Framework for Cryptography

    Science.gov (United States)

    2015-05-01

    uniformly-distributed natural numbers in [0, ) is shown in Listing 7. RndNat_h is a helper function that samples a natural number with the appro...expect that a skilled Coq developer could complete such a proof in a matter of days (though he may require the help of a cryptographer to develop the

  18. Exploring Logical Reasoning and Mathematical Proof in Grade 6 Elementary School Students

    Science.gov (United States)

    Flegas, Konstantinos; Charalampos, Lemonidis

    2013-01-01

    Research and classroom experience reveal that the construction of mathematical proofs is difficult for all students. While many contemporary mathematics curricula recognize the importance of teaching reasoning and proof, in Greece these concepts are introduced at the secondary education level. In this study, we will attempt to investigate a group…

  19. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

    Science.gov (United States)

    Notohamiprodjo, S; Deak, Z; Meurer, F; Maertz, F; Mueck, F G; Geyer, L L; Wirth, S

    2015-01-01

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p ASiR was 2 (p ASiR (p ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.

  20. Efficient, fair, and strategy-proof (re)allocation under network constraints

    DEFF Research Database (Denmark)

    Szwagrzak, Karol

    2017-01-01

    A resource available in different types is to be distributed or redistributed among agents differing in their ability to consume these types. Preferences over consumption levels are not observable but known to be single-peaked. We identify the only strategy-proof and efficient allocation rule...... to a new class of group strategy-proof rules. Our analysis provides a unified treatment of the applications in Bochet et al. (Theor Econ 7:395–423, 2012, J Econ Theory 148:535–562, 2013)....