WorldWideScience

Sample records for multiparameter performance evaluation

  1. Evaluation for Bearing Wear States Based on Online Oil Multi-Parameters Monitoring

    Science.gov (United States)

    Hu, Hai-Feng

    2018-01-01

    As bearings are critical components of a mechanical system, it is important to characterize their wear states and evaluate health conditions. In this paper, a novel approach for analyzing the relationship between online oil multi-parameter monitoring samples and bearing wear states has been proposed based on an improved gray k-means clustering model (G-KCM). First, an online monitoring system with multiple sensors for bearings is established, obtaining oil multi-parameter data and vibration signals for bearings through the whole lifetime. Secondly, a gray correlation degree distance matrix is generated using a gray correlation model (GCM) to express the relationship of oil monitoring samples at different times and then a KCM is applied to cluster the matrix. Analysis and experimental results show that there is an obvious correspondence that state changing coincides basically in time between the lubricants’ multi-parameters and the bearings’ wear states. It also has shown that online oil samples with multi-parameters have early wear failure prediction ability for bearings superior to vibration signals. It is expected to realize online oil monitoring and evaluation for bearing health condition and to provide a novel approach for early identification of bearing-related failure modes. PMID:29621175

  2. Evaluation for Bearing Wear States Based on Online Oil Multi-Parameters Monitoring

    Directory of Open Access Journals (Sweden)

    Si-Yuan Wang

    2018-04-01

    Full Text Available As bearings are critical components of a mechanical system, it is important to characterize their wear states and evaluate health conditions. In this paper, a novel approach for analyzing the relationship between online oil multi-parameter monitoring samples and bearing wear states has been proposed based on an improved gray k-means clustering model (G-KCM. First, an online monitoring system with multiple sensors for bearings is established, obtaining oil multi-parameter data and vibration signals for bearings through the whole lifetime. Secondly, a gray correlation degree distance matrix is generated using a gray correlation model (GCM to express the relationship of oil monitoring samples at different times and then a KCM is applied to cluster the matrix. Analysis and experimental results show that there is an obvious correspondence that state changing coincides basically in time between the lubricants’ multi-parameters and the bearings’ wear states. It also has shown that online oil samples with multi-parameters have early wear failure prediction ability for bearings superior to vibration signals. It is expected to realize online oil monitoring and evaluation for bearing health condition and to provide a novel approach for early identification of bearing-related failure modes.

  3. Singular multiparameter dynamic equations with distributional ...

    African Journals Online (AJOL)

    Singular multiparameter dynamic equations with distributional potentials on time scales. ... In this paper, we consider both singular single and several multiparameter ... multiple function which is of one sign and nonzero on the given time scale.

  4. Estimating reliability of degraded system based on the probability density evolution with multi-parameter

    Directory of Open Access Journals (Sweden)

    Jiang Ge

    2017-01-01

    Full Text Available System degradation was usually caused by multiple-parameter degradation. The assessment result of system reliability by universal generating function was low accurate when compared with the Monte Carlo simulation. And the probability density function of the system output performance cannot be got. So the reliability assessment method based on the probability density evolution with multi-parameter was presented for complexly degraded system. Firstly, the system output function was founded according to the transitive relation between component parameters and the system output performance. Then, the probability density evolution equation based on the probability conservation principle and the system output function was established. Furthermore, probability distribution characteristics of the system output performance was obtained by solving differential equation. Finally, the reliability of the degraded system was estimated. This method did not need to discrete the performance parameters and can establish continuous probability density function of the system output performance with high calculation efficiency and low cost. Numerical example shows that this method is applicable to evaluate the reliability of multi-parameter degraded system.

  5. Real-time multiparameter pulse processing with decision tables

    International Nuclear Information System (INIS)

    Hull, K.; Griffin, H.

    1986-01-01

    Decision tables offer several advantages over other real-time multiparameter, data processing techniques. These include very high collection rates, minimum number of computer instructions, rates independent of the number of conditions applied per parameter, ease of adding or removing conditions during a session, and simplicity of implementation. Decisions table processing is important in multiparameter nuclear spectroscopy, coincidence experiments, multiparameter pulse processing (HgI 2 resolution enhancement, pulse discrimination, timing spectroscopy), and other applications can be easily implemented. (orig.)

  6. Real-time multi-parameter cell-based analysis platform

    DEFF Research Database (Denmark)

    Caviglia, Claudia

    biomedical diagnostic techniques, drug discovery and screening. My project focused on the further development, improvement and exploration of the EXCELL microfluidic platform with particular interest in drug kinetic monitoring and neurotransmitter detection. The aim was to perform multi-parameter real...... of protocols and procedures for performing different cellular assays. (2) Electrochemical impedance spectroscopy (EIS) applied for drug screening and drug delivery in cancer research and wound healing studies. (3) Amperometry for monitoring of neurotransmitter exocytosis, relevant in research on Parkinson...

  7. Ultra-Weak Fiber Bragg Grating Sensing Network Coated with Sensitive Material for Multi-Parameter Measurements

    Directory of Open Access Journals (Sweden)

    Wei Bai

    2017-06-01

    Full Text Available A multi-parameter measurement system based on ultra-weak fiber Bragg grating (UFBG array with sensitive material was proposed and experimentally demonstrated. The UFBG array interrogation principle is time division multiplex technology with two semiconductor optical amplifiers as timing units. Experimental results showed that the performance of the proposed UFBG system is almost equal to that of traditional FBG, while the UFBG array system has obvious superiority with potential multiplexing ability for multi-point and multi-parameter measurement. The system experimented on a 144 UFBG array with the reflectivity of UFBG ~0.04% for the four target parameters: hydrogen, humidity, temperature and salinity. Moreover, a uniform solution was customized to divide the cross-sensitivity between temperature and other target parameters. It is expected that this scheme will be capable of handling thousands of multi-parameter sensors in a single fiber.

  8. Ultra-Weak Fiber Bragg Grating Sensing Network Coated with Sensitive Material for Multi-Parameter Measurements.

    Science.gov (United States)

    Bai, Wei; Yang, Minghong; Hu, Chenyuan; Dai, Jixiang; Zhong, Xuexiang; Huang, Shuai; Wang, Gaopeng

    2017-06-26

    A multi-parameter measurement system based on ultra-weak fiber Bragg grating (UFBG) array with sensitive material was proposed and experimentally demonstrated. The UFBG array interrogation principle is time division multiplex technology with two semiconductor optical amplifiers as timing units. Experimental results showed that the performance of the proposed UFBG system is almost equal to that of traditional FBG, while the UFBG array system has obvious superiority with potential multiplexing ability for multi-point and multi-parameter measurement. The system experimented on a 144 UFBG array with the reflectivity of UFBG ~0.04% for the four target parameters: hydrogen, humidity, temperature and salinity. Moreover, a uniform solution was customized to divide the cross-sensitivity between temperature and other target parameters. It is expected that this scheme will be capable of handling thousands of multi-parameter sensors in a single fiber.

  9. Multi-parameter study of gammas capture

    International Nuclear Information System (INIS)

    Samama, R.; Nifenecker, H.; Carlos, P.; Delaitre, B.

    1966-06-01

    This equipment is intended for analyzing, recording, and reading simultaneous information from several 'gamma' detectors. It allows multiparameter study of γ-γ cascades emitted after thermal neutrons capture. (authors) [fr

  10. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  11. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Holt, K.; Ingebretsen, F.; Skaali, B.

    1983-01-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configurations of singles and multiparameter events from 1 up to 15 ADC's in one crate

  12. Analysis of immunophenotype in acute myeloid leukemia by multiparameter flow cytometry

    International Nuclear Information System (INIS)

    Gao Yanqun; Jin Haijie; Yan Pei; Wang Feifei; Li Xiaohong; Gao Chunji

    2005-01-01

    To evaluate the immunophenotype of acute leukemia patients, the surface and cytoplasmic antigen expression in 162 cases of acute leukemia were analyzed by multiparameter flow cytometry and CD45/SSC gating. The results showed that CDl17 (94.9%), CD13 (88.5%) and CD33(70.5%) were mainly expressed in ANLL patients; cCD79a(100%), CD19(92.1%) were chiefly expressed in B-ALL patients, and in T-ALL patients, cCD3(100%) and CD2(83.3%) were expressed; For the expression of lymphoid differentiation antigen Ly+ANLL, CD7 (56.2%) and CD19(31.2%) were chiefly found, and for myeloid antigen My+ALL, CD13(88. 9%) and CD33 (27.8%) were detected. In conclusion, multiparameter flow cytometry and three-color direct immunofluorescence staining methods may be of important clinical significance in diagnosis, therapy and prognosis of acute leukemia. (authors)

  13. A technique to obtain a multiparameter radar rainfall algorithm using the probability matching procedure

    International Nuclear Information System (INIS)

    Gorgucci, E.; Scarchilli, G.

    1997-01-01

    The natural cumulative distributions of rainfall observed by a network of rain gauges and a multiparameter radar are matched to derive multiparameter radar algorithms for rainfall estimation. The use of multiparameter radar measurements in a statistical framework to estimate rainfall is resented in this paper, The techniques developed in this paper are applied to the radar and rain gauge measurement of rainfall observed in central Florida and central Italy. Conventional pointwise estimates of rainfall are also compared. The probability matching procedure, when applied to the radar and surface measurements, shows that multiparameter radar algorithms can match the probability distribution function better than the reflectivity-based algorithms. It is also shown that the multiparameter radar algorithm derived matching the cumulative distribution function of rainfall provides more accurate estimates of rainfall on the ground in comparison to any conventional reflectivity-based algorithm

  14. Multi-parameter sensor based on random fiber lasers

    Directory of Open Access Journals (Sweden)

    Yanping Xu

    2016-09-01

    Full Text Available We demonstrate a concept of utilizing random fiber lasers to achieve multi-parameter sensing. The proposed random fiber ring laser consists of an erbium-doped fiber as the gain medium and a random fiber grating as the feedback. The random feedback is effectively realized by a large number of reflections from around 50000 femtosecond laser induced refractive index modulation regions over a 10cm standard single mode fiber. Numerous polarization-dependent spectral filters are formed and superimposed to provide multiple lasing lines with high signal-to-noise ratio up to 40dB, which gives an access for a high-fidelity multi-parameter sensing scheme. The number of sensing parameters can be controlled by the number of the lasing lines via input polarizations and wavelength shifts of each peak can be explored for the simultaneous multi-parameter sensing with one sensing probe. In addition, the random grating induced coupling between core and cladding modes can be potentially used for liquid medical sample sensing in medical diagnostics, biology and remote sensing in hostile environments.

  15. Multiparameter Stochastic Dynamics of Ecological Tourism System with Continuous Visitor Education Interventions

    Directory of Open Access Journals (Sweden)

    Dongping Wei

    2015-01-01

    Full Text Available Management of ecological tourism in protected areas faces many challenges, with visitation-related resource degradations and cultural impacts being two of them. To address those issues, several strategies including regulations, site managements, and visitor education programs have been commonly used in China and other countries. This paper presents a multiparameter stochastic differential equation model of an Ecological Tourism System to study how the populations of stakeholders vary in a finite time. The solution of Ordinary Differential Equation of Ecological Tourism System reveals that the system collapses when there is a lack of visitor educational intervention. Hence, the Stochastic Dynamic of Ecological Tourism System is introduced to suppress the explosion of the system. But the simulation results of the Stochastic Dynamic of Ecological Tourism System show that the system is still unstable and chaos in some small time interval. The Multiparameters Stochastic Dynamics of Ecological Tourism System is proposed to improve the performance in this paper. The Multiparameters Stochastic Dynamics of Ecological Tourism System not only suppresses the explosion of the system in a finite time, but also keeps the populations of stakeholders in an acceptable level. In conclusion, the Ecological Tourism System develops steadily and sustainably when land managers employ effective visitor education intervention programs to deal with recreation impacts.

  16. Multiparameter extrapolation and deflation methods for solving equation systems

    Directory of Open Access Journals (Sweden)

    A. J. Hughes Hallett

    1984-01-01

    Full Text Available Most models in economics and the applied sciences are solved by first order iterative techniques, usually those based on the Gauss-Seidel algorithm. This paper examines the convergence of multiparameter extrapolations (accelerations of first order iterations, as an improved approximation to the Newton method for solving arbitrary nonlinear equation systems. It generalises my earlier results on single parameter extrapolations. Richardson's generalised method and the deflation method for detecting successive solutions in nonlinear equation systems are also presented as multiparameter extrapolations of first order iterations. New convergence results are obtained for those methods.

  17. Multi-parameter CAMAC compatible ADC scanner

    Energy Technology Data Exchange (ETDEWEB)

    Midttun, G J; Ingebretsen, F [Oslo Univ. (Norway). Fysisk Inst.; Johnsen, P J [Norsk Data A.S., Box 163, Oekern, Oslo 5, Norway

    1979-02-15

    A fast ADC scanner for multi-parameter nuclear physics experiments is described. The scanner is based on a standard CAMAC crate, and data from several different experiments can be handled simultaneously through a direct memory access (DMA) channel. The implementation on a PDP-7 computer is outlined.

  18. Density reconstruction in multiparameter elastic full-waveform inversion

    Science.gov (United States)

    Sun, Min'ao; Yang, Jizhong; Dong, Liangguo; Liu, Yuzhu; Huang, Chao

    2017-12-01

    Elastic full-waveform inversion (EFWI) is a quantitative data fitting procedure that recovers multiple subsurface parameters from multicomponent seismic data. As density is involved in addition to P- and S-wave velocities, the multiparameter EFWI suffers from more serious tradeoffs. In addition, compared with P- and S-wave velocities, the misfit function is less sensitive to density perturbation. Thus, a robust density reconstruction remains a difficult problem in multiparameter EFWI. In this paper, we develop an improved scattering-integral-based truncated Gauss-Newton method to simultaneously recover P- and S-wave velocities and density in EFWI. In this method, the inverse Gauss-Newton Hessian has been estimated by iteratively solving the Gauss-Newton equation with a matrix-free conjugate gradient algorithm. Therefore, it is able to properly handle the parameter tradeoffs. To give a detailed illustration of the tradeoffs between P- and S-wave velocities and density in EFWI, wavefield-separated sensitivity kernels and the Gauss-Newton Hessian are numerically computed, and their distribution characteristics are analyzed. Numerical experiments on a canonical inclusion model and a modified SEG/EAGE Overthrust model have demonstrated that the proposed method can effectively mitigate the tradeoff effects, and improve multiparameter gradients. Thus, a high convergence rate and an accurate density reconstruction can be achieved.

  19. Multiparameter optimization of mammography: an update

    Science.gov (United States)

    Jafroudi, Hamid; Muntz, E. P.; Jennings, Robert J.

    1994-05-01

    Previously in this forum we have reported the application of multiparameter optimization techniques to the design of a minimum dose mammography system. The approach used a reference system to define the physical imaging performance required and the dose to which the dose for the optimized system should be compared. During the course of implementing the resulting design in hardware suitable for laboratory testing, the state of the art in mammographic imaging changed, so that the original reference system, which did not have a grid, was no longer appropriate. A reference system with a grid was selected in response to this change, and at the same time the optimization procedure was modified, to make it more general and to facilitate study of the optimized design under a variety of conditions. We report the changes in the procedure, and the results obtained using the revised procedure and the up- to-date reference system. Our results, which are supported by laboratory measurements, indicate that the optimized design can image small objects as well as the reference system using only about 30% of the dose required by the reference system. Hardware meeting the specification produced by the optimization procedure and suitable for clinical use is currently under evaluation in the Diagnostic Radiology Department at the Clinical Center, NH.

  20. Multiparameter Inversion: Cramer's Rule for Pseudodifferential Operators

    Directory of Open Access Journals (Sweden)

    Rami Nammour

    2011-01-01

    a matrix. The approximate solution of the linearized multiparameter problem so produced involves no ray theory computations. It may be sufficiently accurate for some purposes; for others, it can serve as a preconditioner to enhance the convergence of standard iterative methods.

  1. The generalized fracture criteria based on the multi-parameter representation of the crack tip stress field

    Science.gov (United States)

    Stepanova, L. V.

    2017-12-01

    The paper is devoted to the multi-parameter asymptotic description of the stress field near the crack tip of a finite crack in an infinite isotropic elastic plane medium subject to 1) tensile stress; 2) in-plane shear; 3) mixed mode loading for a wide range of mode-mixity situations (Mode I and Mode II). The multi-parameter series expansion of stress tensor components containing higher-order terms is obtained. All the coefficients of the multiparameter series expansion of the stress field are given. The main focus is on the discussion of the influence of considering the higher-order terms of the Williams expansion. The analysis of the higher-order terms in the stress field is performed. It is shown that the larger the distance from the crack tip, the more terms it is necessary to keep in the asymptotic series expansion. Therefore, it can be concluded that several more higher-order terms of the Williams expansion should be used for the stress field description when the distance from the crack tip is not small enough. The crack propagation direction angle is calculated. Two fracture criteria, the maximum tangential stress criterion and the strain energy density criterion, are used. The multi-parameter form of the two commonly used fracture criteria is introduced and tested. Thirty and more terms of the Williams series expansion for the near-crack-tip stress field enable the angle to be calculated more precisely.

  2. A nuclear radiation multi-parameter measurement system based on pulse-shape sampling

    International Nuclear Information System (INIS)

    Qiu Xiaolin; Fang Guoming; Xu Peng; Di Yuming

    2007-01-01

    In this paper, A nuclear radiation multi-parameter measurement system based on pulse-shape sampling is introduced, including the system's characteristics, composition, operating principle, experiment data and analysis. Compared with conventional nuclear measuring apparatus, it has some remarkable advantages such as the synchronous detection using multi-parameter measurement in the same measurement platform and the general analysis of signal data by user-defined program. (authors)

  3. Multi-parameter optimization design of parabolic trough solar receiver

    International Nuclear Information System (INIS)

    Guo, Jiangfeng; Huai, Xiulan

    2016-01-01

    Highlights: • The optimal condition can be obtained by multi-parameter optimization. • Exergy and thermal efficiencies are employed as objective function. • Exergy efficiency increases at the expense of heat losses. • The heat obtained by working fluid increases as thermal efficiency grows. - Abstract: The design parameters of parabolic trough solar receiver are interrelated and interact with one another, so the optimal performance of solar receiver cannot be obtained by the convectional single-parameter optimization. To overcome the shortcoming of single-parameter optimization, a multi-parameter optimization of parabolic trough solar receiver is employed based on genetic algorithm in the present work. When the thermal efficiency is taken as the objective function, the heat obtained by working fluid increases while the average temperature of working fluid and wall temperatures of solar receiver decrease. The average temperature of working fluid and the wall temperatures of solar receiver increase while the heat obtained by working fluid decreases generally by taking the exergy efficiency as an objective function. Assuming that the solar radiation intensity remains constant, the exergy obtained by working fluid increases by taking exergy efficiency as the objective function, which comes at the expense of heat losses of solar receiver.

  4. Large capacity, high-speed multiparameter multichannel analysis system

    International Nuclear Information System (INIS)

    Hendricks, R.W.; Seeger, P.A.; Scheer, J.W.; Suehiro, S.

    1980-01-01

    A data acquisition system for recording multiparameter digital data into a large memory array at over 2.5 MHz is described. The system consists of a MOSTEK MK8600 2048K x 24-bit memory system, I/O ports to various external devices including the CAMAC dataway, a memory incrementer/adder and a daisy-chain of experiment-specific modules which calculate the memory address which is to be incremented. The design of the daisy-chain permits multiple modules and provides for easy modification as experimental needs change. The system has been designed for use in multiparameter, multichannel analysis of high-speed data gathered by position-sensitive detectors at conventional and synchrotron x-ray sources as well as for fixed energy and time-of-flight diffraction at continuous and pulsed neutron sources

  5. Power capability evaluation for lithium iron phosphate batteries based on multi-parameter constraints estimation

    Science.gov (United States)

    Wang, Yujie; Pan, Rui; Liu, Chang; Chen, Zonghai; Ling, Qiang

    2018-01-01

    The battery power capability is intimately correlated with the climbing, braking and accelerating performance of the electric vehicles. Accurate power capability prediction can not only guarantee the safety but also regulate driving behavior and optimize battery energy usage. However, the nonlinearity of the battery model is very complex especially for the lithium iron phosphate batteries. Besides, the hysteresis loop in the open-circuit voltage curve is easy to cause large error in model prediction. In this work, a multi-parameter constraints dynamic estimation method is proposed to predict the battery continuous period power capability. A high-fidelity battery model which considers the battery polarization and hysteresis phenomenon is presented to approximate the high nonlinearity of the lithium iron phosphate battery. Explicit analyses of power capability with multiple constraints are elaborated, specifically the state-of-energy is considered in power capability assessment. Furthermore, to solve the problem of nonlinear system state estimation, and suppress noise interference, the UKF based state observer is employed for power capability prediction. The performance of the proposed methodology is demonstrated by experiments under different dynamic characterization schedules. The charge and discharge power capabilities of the lithium iron phosphate batteries are quantitatively assessed under different time scales and temperatures.

  6. Equilibrium radionuclide ventriculography: Comparison with echo-ventriculography and digital subtraction angiocardiography, evaluation of multiparameters

    Energy Technology Data Exchange (ETDEWEB)

    Hoer, G; Standke, R; Klepzig, H Jr; Maul, F D; Tuengerthal, S; Tezak, S; Reifarth, N; Kanemoto, N; Happ, J; Baum, R P

    1986-09-01

    Subsequent to the discussion of technical prerequisites (fully-automated, reproducible multiparameter-analysis (MPA), rest, exercise) which is followed by remarks concerning the pathophysiology of ischemic left ventricular functional disorders in diastole and systole, the following points are considered: 1) comparative results of RNV, cineventriculoangiography, echo-ventriculography and intraveneous digital subtraction angiocardiography; 2) 'normal' values of RNV in MPA; 3) heart and pulmonary diseases (coronary artery disease with sensitivity and specificity of MPA), chronic obstructive pulmonary disease, chronic aortic insufficiency, hypertension; 4) summary of, and prospects for future potentialities (software, clinical indications).

  7. Methods and apparatus for multi-parameter acoustic signature inspection

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Aaron A [Richland, WA; Samuel, Todd J [Pasco, WA; Valencia, Juan D [Kennewick, WA; Gervais, Kevin L [Richland, WA; Tucker, Brian J [Pasco, WA; Kirihara, Leslie J [Richland, WA; Skorpik, James R [Kennewick, WA; Reid, Larry D [Benton City, WA; Munley, John T [Benton City, WA; Pappas, Richard A [Richland, WA; Wright, Bob W [West Richland, WA; Panetta, Paul D [Richland, WA; Thompson, Jason S [Richland, WA

    2007-07-24

    A multiparameter acoustic signature inspection device and method are described for non-invasive inspection of containers. Dual acoustic signatures discriminate between various fluids and materials for identification of the same.

  8. BioMEMS for multiparameter clinical monitoring

    Science.gov (United States)

    Moser, Isabella

    2003-01-01

    For diabetes patients glucose monitoring means an important improvement of their life quality and additionally it is a $3-billion-a-year business. Continuous glucose monitoring provides gapless glucose level control, an early warning of hypoglycemia, and is intended to control insulin pumps. An upgrading to multi-parameter monitoring would not only benefit patients with severe metabolism defects but also the metabolism of diabetes patient could be better controlled by monitoring an additional parameter like lactate. Multi-parameter monitoring devices are not commercially available, one of the complications in the integration of different biosensors using the same detecting molecule for all analytes is chemical cross talk between adjacent amperometric biosensors. Recently some integrated biosensors were published but either they were not mass producible or they were realized in an expensive silicon based technology. In addition to it most of them were not tested under monitoring conditions but their integration principles will be discussed. As an example a low cost multi- parameter microsystem and some applications of it in clinical diagnosis will be presented. Also an overlook of non-invasive methods and (minimal) invasive methods will be given with a focus on microdialysis.

  9. Multi-Parameter Measurement in Unseeded Flows using Femtosecond Lasers

    Data.gov (United States)

    National Aeronautics and Space Administration — Our approach is to use new turn-key femtosecond laser technology along with new high-speed CMOS camera technology to build a multi-parameter measurement system based...

  10. Sensitivity analysis in multi-parameter probabilistic systems

    International Nuclear Information System (INIS)

    Walker, J.R.

    1987-01-01

    Probabilistic methods involving the use of multi-parameter Monte Carlo analysis can be applied to a wide range of engineering systems. The output from the Monte Carlo analysis is a probabilistic estimate of the system consequence, which can vary spatially and temporally. Sensitivity analysis aims to examine how the output consequence is influenced by the input parameter values. Sensitivity analysis provides the necessary information so that the engineering properties of the system can be optimized. This report details a package of sensitivity analysis techniques that together form an integrated methodology for the sensitivity analysis of probabilistic systems. The techniques have known confidence limits and can be applied to a wide range of engineering problems. The sensitivity analysis methodology is illustrated by performing the sensitivity analysis of the MCROC rock microcracking model

  11. Multiparameter probability distributions for heavy rainfall modeling in extreme southern Brazil

    Directory of Open Access Journals (Sweden)

    Samuel Beskow

    2015-09-01

    New hydrological insights for the region: The Anderson–Darling and Filliben tests were the most restrictive in this study. Based on the Anderson–Darling test, it was found that the Kappa distribution presented the best performance, followed by the GEV. This finding provides evidence that these multiparameter distributions result, for the region of study, in greater accuracy for the generation of intensity–duration–frequency curves and the prediction of peak streamflows and design hydrographs. As a result, this finding can support the design of hydraulic structures and flood management in river basins.

  12. CIMI simulations with recently developed multi-parameter chorus and plasmaspheric hiss models

    Science.gov (United States)

    Aryan, Homayon; Sibeck, David; Kang, Suk-bin; Balikhin, Michael; Fok, Mei-ching

    2017-04-01

    Simulation studies of the Earth's radiation belts are very useful in understanding the acceleration and loss of energetic particles. The Comprehensive Inner Magnetosphere-Ionosphere (CIMI) model considers the effects of the ring current and plasmasphere on the radiation belts. CIMI was formed by merging the Comprehensive Ring Current Model (CRCM) and the Radiation Belt Environment (RBE) model to solves for many essential quantities in the inner magnetosphere, including radiation belt enhancements and dropouts. It incorporates chorus and plasmaspheric hiss wave diffusion of energetic electrons in energy, pitch angle, and cross terms. Usually the chorus and plasmaspheric hiss models used in CIMI are based on single-parameter geomagnetic index (AE). Here we integrate recently developed multi-parameter chorus and plasmaspheric hiss wave models based on geomagnetic index and solar wind parameters. We then perform CIMI simulations for different storms and compare the results with data from the Van Allen Probes and the Two Wide-angle Imaging Neutral-atom Spectrometers and Akebono satellites. We find that the CIMI simulations with multi-parameter chorus and plasmaspheric hiss wave models are more comparable to data than the single-parameter wave models.

  13. A Smart Multi-parameter Sensor with Online Monitoring for the Aquaculture in China

    OpenAIRE

    Peng , Fa; Wang , Jinxing; Liu , Shuangxi; Li , Daoliang; Xu , Dan; Wang , Yang

    2013-01-01

    International audience; PH, DO,ORP, EC and water-level are important parameters of the aquaculture monitoring. But the high cost of foreign sensors and high-energy consumption of Chinese sensors make it impossible for wide use in China. This paper uses MCU STM8L152 to realize the ultralow power design. With simple hardware structure design, the cost of the multi-parameter sensor can be reduced .The experiment data of the multi-parameter sensor contrasting with the results obtained by Hach mul...

  14. Slow coincidences for CAMAC multiparameter analysis

    International Nuclear Information System (INIS)

    Akimov, Yu.K.; Kalinin, A.I.; Tissol'd, E.; Fromm, V.D.; Ekstein, P.

    1978-01-01

    A coincidence circuit with controlled parameters is described. The circuit has six coincidence inputs and one input for anticoincidences. A pulse duration in channels is changed from 0.25 to 5 μs and delay time, within 8 μs. The circuit is developed for multiparameter spectrometric analysis with the use of amplitude-digital and time-digital convertors. Its introduction permits one to diminish considerably the ''dead'' time of apparatus and to select rapidly and reliably strictly correlated digital information from convertors

  15. Realization of multi-parameter and multi-state in fault tree computer-aided building software

    International Nuclear Information System (INIS)

    Guo Xiaoli; Tong Jiejuan; Xue Dazhi

    2004-01-01

    More than one parameter and more than one failed state of a parameter are often involved in building fault tree, so it is necessary for fault tree computer-aided building software to deal with multi-parameter and multi-state. Fault Tree Expert System (FTES) has the target of aiding the FT-building work of hydraulic systems. This paper expatiates on how to realize multi-parameter and multi-state in FTES with focus on Knowledge Base and Illation Engine. (author)

  16. Application of multi-parameter chorus and plasmaspheric hiss wave models in radiation belt modeling

    Science.gov (United States)

    Aryan, H.; Kang, S. B.; Balikhin, M. A.; Fok, M. C. H.; Agapitov, O. V.; Komar, C. M.; Kanekal, S. G.; Nagai, T.; Sibeck, D. G.

    2017-12-01

    Numerical simulation studies of the Earth's radiation belts are important to understand the acceleration and loss of energetic electrons. The Comprehensive Inner Magnetosphere-Ionosphere (CIMI) model along with many other radiation belt models require inputs for pitch angle, energy, and cross diffusion of electrons, due to chorus and plasmaspheric hiss waves. These parameters are calculated using statistical wave distribution models of chorus and plasmaspheric hiss amplitudes. In this study we incorporate recently developed multi-parameter chorus and plasmaspheric hiss wave models based on geomagnetic index and solar wind parameters. We perform CIMI simulations for two geomagnetic storms and compare the flux enhancement of MeV electrons with data from the Van Allen Probes and Akebono satellites. We show that the relativistic electron fluxes calculated with multi-parameter wave models resembles the observations more accurately than the relativistic electron fluxes calculated with single-parameter wave models. This indicates that wave models based on a combination of geomagnetic index and solar wind parameters are more effective as inputs to radiation belt models.

  17. CIMI simulations with newly developed multiparameter chorus and plasmaspheric hiss wave models

    Science.gov (United States)

    Aryan, Homayon; Sibeck, David G.; Kang, Suk-Bin; Balikhin, Michael A.; Fok, Mei-Ching; Agapitov, Oleksiy; Komar, Colin M.; Kanekal, Shrikanth G.; Nagai, Tsugunobu

    2017-09-01

    Numerical simulation studies of the Earth's radiation belts are important to understand the acceleration and loss of energetic electrons. The Comprehensive Inner Magnetosphere-Ionosphere (CIMI) model considers the effects of the ring current and plasmasphere on the radiation belts to obtain plausible results. The CIMI model incorporates pitch angle, energy, and cross diffusion of electrons, due to chorus and plasmaspheric hiss waves. These parameters are calculated using statistical wave distribution models of chorus and plasmaspheric hiss amplitudes. However, currently, these wave distribution models are based only on a single-parameter, geomagnetic index (AE) and could potentially underestimate the wave amplitudes. Here we incorporate recently developed multiparameter chorus and plasmaspheric hiss wave models based on geomagnetic index and solar wind parameters. We then perform CIMI simulations for two geomagnetic storms and compare the flux enhancement of MeV electrons with data from the Van Allen Probes and Akebono satellites. We show that the relativistic electron fluxes calculated with multiparameter wave models resemble the observations more accurately than the relativistic electron fluxes calculated with single-parameter wave models. This indicates that wave models based on a combination of geomagnetic index and solar wind parameters are more effective as inputs to radiation belt models.

  18. Ultra-Weak Fiber Bragg Grating Sensing Network Coated with Sensitive Material for Multi-Parameter Measurements

    OpenAIRE

    Bai, Wei; Yang, Minghong; Hu, Chenyuan; Dai, Jixiang; Zhong, Xuexiang; Huang, Shuai; Wang, Gaopeng

    2017-01-01

    A multi-parameter measurement system based on ultra-weak fiber Bragg grating (UFBG) array with sensitive material was proposed and experimentally demonstrated. The UFBG array interrogation principle is time division multiplex technology with two semiconductor optical amplifiers as timing units. Experimental results showed that the performance of the proposed UFBG system is almost equal to that of traditional FBG, while the UFBG array system has obvious superiority with potential multiplexing ...

  19. A large capacity, high-speed multiparameter multichannel analysis system

    International Nuclear Information System (INIS)

    Hendricks, R.W.; Suehiro, S.; Seeger, P.A.; Scheer, J.W.

    1982-01-01

    A data acquisition system for recording multiparameter digital data into a large memory array at over 2.5 MHz is described. The system consists of a MOSTEK MK 8600 2048 K x 24-bit memory system, I/O ports to various external devices including the CAMAC dataway, a memory incrementer/adder and a daisy-chain of experiment-specific modules which calculate the memory address which is to be incremented. The design of the daisy-chain permits multiple modules and provides for easy modification as experimental needs change. The system has been designed for use in multiparameter, multichannel analysis of high-speed data gathered by position-sensitive detectors at conventional and synchrotron X-ray sources as well as for fixed energy and time-of-flight diffraction at continuous and pulsed neutron sources. Modules which have been developed to date include a buffer for two-dimensional position-sensitive detectors, a mapper for high-speed coordinate transformations, a buffered time-of-flight clock, a time-correlator for synchronized diffraction experiments, and a display unit for data bus diagnostics. (orig.)

  20. Multi-parameter full waveform inversion using Poisson

    KAUST Repository

    Oh, Juwon

    2016-07-21

    In multi-parameter full waveform inversion (FWI), the success of recovering each parameter is dependent on characteristics of the partial derivative wavefields (or virtual sources), which differ according to parameterisation. Elastic FWIs based on the two conventional parameterisations (one uses Lame constants and density; the other employs P- and S-wave velocities and density) have low resolution of gradients for P-wave velocities (or ). Limitations occur because the virtual sources for P-wave velocity or (one of the Lame constants) are related only to P-P diffracted waves, and generate isotropic explosions, which reduce the spatial resolution of the FWI for these parameters. To increase the spatial resolution, we propose a new parameterisation using P-wave velocity, Poisson\\'s ratio, and density for frequency-domain multi-parameter FWI for isotropic elastic media. By introducing Poisson\\'s ratio instead of S-wave velocity, the virtual source for the P-wave velocity generates P-S and S-S diffracted waves as well as P-P diffracted waves in the partial derivative wavefields for the P-wave velocity. Numerical examples of the cross-triangle-square (CTS) model indicate that the new parameterisation provides highly resolved descent directions for the P-wave velocity. Numerical examples of noise-free and noisy data synthesised for the elastic Marmousi-II model support the fact that the new parameterisation is more robust for noise than the two conventional parameterisations.

  1. Frequency Domain Multi-parameter Full Waveform Inversion for Acoustic VTI Media

    KAUST Repository

    Djebbi, Ramzi; Alkhalifah, Tariq Ali

    2017-01-01

    Multi-parameter full waveform inversion (FWI) for transversely isotropic (TI) media with vertical axis of symmetry (VTI) suffers from the trade-off between the parameters. The trade-off results in the leakage of one parameter's update into the other

  2. A multi-parameter, acquisition system positron annihilation lifetime spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.

    2004-01-01

    A positron annihilation lifetime spectrometer employing a multi-parameter acquisition system has been prepared for various purposes such as the investigation and characterization of solid-state materials. The fast-fast coincidence technique was used in the present spectrometer with a pair of plastic scintillation detectors. The acquisition system is based on the Kmax software and on CAMAC modules. The data are acquired in event-by-event list mode. The time spectrum for the desired energy windows can be obtained by off-line data sorting and analysis. The spectrometer for event-by-event data acquisition is an important step to construct a positron age-momentum correlation (AMOC) spectrometer. The AMOC technique is especially suited for the observation of positron transitions between different states during their lifetime. The system performance was tested and the results were presented and discussed

  3. A Nonlinear Multiparameters Temperature Error Modeling and Compensation of POS Applied in Airborne Remote Sensing System

    Directory of Open Access Journals (Sweden)

    Jianli Li

    2014-01-01

    Full Text Available The position and orientation system (POS is a key equipment for airborne remote sensing systems, which provides high-precision position, velocity, and attitude information for various imaging payloads. Temperature error is the main source that affects the precision of POS. Traditional temperature error model is single temperature parameter linear function, which is not sufficient for the higher accuracy requirement of POS. The traditional compensation method based on neural network faces great problem in the repeatability error under different temperature conditions. In order to improve the precision and generalization ability of the temperature error compensation for POS, a nonlinear multiparameters temperature error modeling and compensation method based on Bayesian regularization neural network was proposed. The temperature error of POS was analyzed and a nonlinear multiparameters model was established. Bayesian regularization method was used as the evaluation criterion, which further optimized the coefficients of the temperature error. The experimental results show that the proposed method can improve temperature environmental adaptability and precision. The developed POS had been successfully applied in airborne TSMFTIS remote sensing system for the first time, which improved the accuracy of the reconstructed spectrum by 47.99%.

  4. [Multiparameter magnetic resonance imaging in the diagnosis of cancer of the cervix uteri].

    Science.gov (United States)

    Tarachkova, E V; Strel'tsova, O N; Panov, V O; Bazaeva, I Ya; Tyurin, I E

    2015-01-01

    Cancer of the cervix uteri (CCU) ranks third in the incidence of malignancies in women. The choice of CCU treatment mainly depends on the extent of the tumor process, i.e., the stage of the disease. Determining the stage of CCU is based on the clinical classification of the International Federation of Gynecology and Obstetrics (FIGO) (2009) and has a number of substantial limitations in evaluating parametrial invasion, tumor spread to the pelvic wall, and involvement of regional lymph nodes and in determining the true tumor sizes. Magnetic resonance imaging (MRI) is now the method of choice in staging invasive CCU. Multiparameter MRI will be able to enhance the efficiency of diagnosing microinvasive CCU as well (FIGO 2009), to plan surgical and/or chemoradiation treatment, to evaluate its efficiency, and to diagnose locally recurrent CCU.

  5. Rational function systems and electrical networks with multiparameters

    CERN Document Server

    Lu, KaiSheng

    2012-01-01

    To overcome the problems of system theory and network theory over real field, this book uses matrices over the field F(z) of rational functions in multiparameters describing coefficient matrices of systems and networks and makes systems and network description over F(z) and researches their structural properties: reducible condition of a class of matrices over F(z) and their characteristic polynomial; type1 matrix and two basic properties; variable replacement conditions for independent parameters; structural controllability and observability of linear systems over F(z); separability, reducibi

  6. Representations of Urbanik's classes and multiparameter Ornstein-Uhlenbeck processes

    DEFF Research Database (Denmark)

    Graversen, Svend-Erik; Pedersen, Jan

    2011-01-01

    A class of integrals with respect to homogeneous Lévy bases on Rk is considered. In the one-dimensional case k=1 this class corresponds to the selfdecomposable distributions. Necessary and sufficient conditions for existence as well as some representations of the integrals are given. Generalizing...... the one-dimensional case it is shown that the class of integrals corresponds to Urbanik's class Lk-1(R). Finally, multiparameter Ornstein-Uhlenbeck processes are defined and studied....

  7. Quantized planes and multiparameter deformations of Heisenberg and GL(N) algebras

    International Nuclear Information System (INIS)

    Fairlie, D.B.; Zachos, C.

    1991-01-01

    We summarize our work on explicitly deforming classical oscillators to multiparameter quantum oscillators which do not commute with each other. These ''anyonic'' oscillators lead to the construction of a consistent quantum algebra GL q (N) with (N - 1)(N - 2)/2 independent parameters, some of whose features and applications we shall discuss. 22 refs

  8. Frequency Domain Multi-parameter Full Waveform Inversion for Acoustic VTI Media

    KAUST Repository

    Djebbi, Ramzi

    2017-05-26

    Multi-parameter full waveform inversion (FWI) for transversely isotropic (TI) media with vertical axis of symmetry (VTI) suffers from the trade-off between the parameters. The trade-off results in the leakage of one parameter\\'s update into the other during the inversion. It affects the accuracy and convergence of the inversion. The sensitivity analyses suggested a parameterisation using the horizontal velocity vh, epsilon and eta to reduce the trade-off for surface recorded seismic data.We test the (vh, epsilon, eta) parameterisation for acoustic VTI media using a scattering integral (SI) based inversion. The data is modeled in frequency domain and the model is updated using a preconditioned conjugate gradient method. We applied the method to the VTI Marmousi II model and in the inversion, we keep eta parameter fixed as the background initial model and we invert simultaneously for both vh and epsilon. The results show the suitability of the parameterisation for multi-parameter VTI acoustic inversion as well as the accuracy of the inversion approach.

  9. Depth analysis of mechanically machined flaws on steam generator tubings using multi-parameter algorithm

    International Nuclear Information System (INIS)

    Nam Gung, Chan; Lee, Yoon Sang; Hwang, Seong Sik; Kim, Hong Pyo

    2004-01-01

    The eddy current testing (ECT) is a nondestructive technique. It is used for evaluation of material's integrity, especially, steam generator (SG) tubing in nuclear plants, due to their rapid inspection, safe and easy operation. For depth measurement of defects, we prepared Electro Discharge Machined (EDM) notches that have several of defects and applied multi-parameter (MP) algorithm. It is a crack shape estimation program developed in Argonne National Laboratory (ANL). To evaluate the MP algorithm, we compared defect profile with fractography of the defects. In the following sections, we described the basic structure of a computer-aided data analysis algorithm used as means of more accurate and efficient processing of ECT data, and explained the specification of a standard calibration. Finally, we discussed the accuracy of estimated depth profile compared with conventional ECT method

  10. Multi-parameter Analysis and Inversion for Anisotropic Media Using the Scattering Integral Method

    KAUST Repository

    Djebbi, Ramzi

    2017-01-01

    the model. I study the prospect of applying a scattering integral approach for multi-parameter inversion for a transversely isotropic model with a vertical axis of symmetry. I mainly analyze the sensitivity kernels to understand the sensitivity of seismic

  11. Discrimination of land cover from a multiparameter SAR data set

    International Nuclear Information System (INIS)

    Pierdicca, N.; Castracane, P.; Basili, P.; Ciotti, P.; Marzano, F.S.

    2001-01-01

    The identification of the most valuable radar observation parameters (e.g., frequency, polarisation, incidence angle) is important both for designing non-redundant high-performance sensors (i.e. selection of frequency bands and polarizations) and for specifying mission operation requirements (i.e. temporal sampling, incidence angle). Moreover, the task of classifying multiparameter SAR images may require to adopt a strategy that implies the selection of a number of features among those available from this kind of sensors. In this paper it has performed this kind of analysis in a specific area of interest to account for the particular conditions in which remotely sensed data are going to be used. The paper summarises the results of the analysis of the radar data acquired during the MAC Europe '91 and X-SAR/SIR-C campaigns over the Montespertoli test site in Italy. The analysis is based mainly on a statistical approach aiming at demonstrating what is the contribution of different measurements performed by the polarimetric SAR for discriminating the surface coverage. The work is intended to furnish a guideline to develop an optimal strategy for acquiring and processing polarimetric data to be used for land classification

  12. Study of ocean red tide multi-parameter monitoring technology based on double-wavelength airborne lidar system

    Science.gov (United States)

    Lin, Hong; Wang, Xinming; Liang, Kun

    2010-10-01

    For monitoring and forecasting of the ocean red tide in real time, a marine environment monitoring technology based on the double-wavelength airborne lidar system is proposed. An airborne lidar is father more efficient than the traditional measure technology by the boat. At the same time, this technology can detect multi-parameter about the ocean red tide by using the double-wavelength lidar.It not only can use the infrared laser to detect the scattering signal under the water and gain the information about the red tise's density and size, but also can use the blue-green laser to detect the Brillouin scattering signal and deduce the temperature and salinity of the seawater.The red tide's density detecting model is firstly established by introducing the concept about the red tide scattering coefficient based on the Mie scattering theory. From the Brillouin scattering theory, the relationship about the blue-green laser's Brillouin scattering frequency shift value and power value with the seawater temperature and salinity is found. Then, the detecting mode1 of the saewater temperature and salinity can be established. The value of the red tide infrared scattering signal is evaluated by the simulation, and therefore the red tide particles' density can be known. At the same time, the blue-green laser's Brillouin scattering frequency shift value and power value are evaluated by simulating, and the temperature and salinity of the seawater can be known. Baed on the multi-parameters, the ocean red tide's growth can be monitored and forecasted.

  13. Multiparameter Sensor Chip with Barium Strontium Titanate as Multipurpose Material

    OpenAIRE

    Huck, Christina; Poghossian, Arshak; Kerroumi, Iman; Schusser, Sebastian; Backer, Matthias; Zander, Willi; Schubert, Juergen; Buniatyan, Vahe V; Martirosyan, Norayr W; Wagner, Patrick Hermann; Schoning, Michael J

    2014-01-01

    It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and t...

  14. Spectral collocation for multiparameter eigenvalue problems arising from separable boundary value problems

    Science.gov (United States)

    Plestenjak, Bor; Gheorghiu, Călin I.; Hochstenbach, Michiel E.

    2015-10-01

    In numerous science and engineering applications a partial differential equation has to be solved on some fairly regular domain that allows the use of the method of separation of variables. In several orthogonal coordinate systems separation of variables applied to the Helmholtz, Laplace, or Schrödinger equation leads to a multiparameter eigenvalue problem (MEP); important cases include Mathieu's system, Lamé's system, and a system of spheroidal wave functions. Although multiparameter approaches are exploited occasionally to solve such equations numerically, MEPs remain less well known, and the variety of available numerical methods is not wide. The classical approach of discretizing the equations using standard finite differences leads to algebraic MEPs with large matrices, which are difficult to solve efficiently. The aim of this paper is to change this perspective. We show that by combining spectral collocation methods and new efficient numerical methods for algebraic MEPs it is possible to solve such problems both very efficiently and accurately. We improve on several previous results available in the literature, and also present a MATLAB toolbox for solving a wide range of problems.

  15. Numerical Identification of Multiparameters in the Space Fractional Advection Dispersion Equation by Final Observations

    Directory of Open Access Journals (Sweden)

    Dali Zhang

    2012-01-01

    Full Text Available This paper deals with an inverse problem for identifying multiparameters in 1D space fractional advection dispersion equation (FADE on a finite domain with final observations. The parameters to be identified are the fractional order, the diffusion coefficient, and the average velocity in the FADE. The forward problem is solved by a finite difference scheme, and then an optimal perturbation regularization algorithm is introduced to determine the three parameters simultaneously. Numerical inversions are performed both with the accurate data and noisy data, and several factors having influences on realization of the algorithm are discussed. The inversion solutions are in good approximations to the exact solutions demonstrating the efficiency of the proposed algorithm.

  16. Accelerated whole-brain multi-parameter mapping using blind compressed sensing.

    Science.gov (United States)

    Bhave, Sampada; Lingala, Sajan Goud; Johnson, Casey P; Magnotta, Vincent A; Jacob, Mathews

    2016-03-01

    To introduce a blind compressed sensing (BCS) framework to accelerate multi-parameter MR mapping, and demonstrate its feasibility in high-resolution, whole-brain T1ρ and T2 mapping. BCS models the evolution of magnetization at every pixel as a sparse linear combination of bases in a dictionary. Unlike compressed sensing, the dictionary and the sparse coefficients are jointly estimated from undersampled data. Large number of non-orthogonal bases in BCS accounts for more complex signals than low rank representations. The low degree of freedom of BCS, attributed to sparse coefficients, translates to fewer artifacts at high acceleration factors (R). From 2D retrospective undersampling experiments, the mean square errors in T1ρ and T2 maps were observed to be within 0.1% up to R = 10. BCS was observed to be more robust to patient-specific motion as compared to other compressed sensing schemes and resulted in minimal degradation of parameter maps in the presence of motion. Our results suggested that BCS can provide an acceleration factor of 8 in prospective 3D imaging with reasonable reconstructions. BCS considerably reduces scan time for multiparameter mapping of the whole brain with minimal artifacts, and is more robust to motion-induced signal changes compared to current compressed sensing and principal component analysis-based techniques. © 2015 Wiley Periodicals, Inc.

  17. Induction studies with Escherichia coli expressing recombinant interleukin-13 using multi-parameter flow cytometry

    DEFF Research Database (Denmark)

    Shitu, J. O.; Woodley, John; Wnek, R.

    2009-01-01

    The expression of interleukin-13 (IL13) following induction with IPTG in Escherichia coli results in metabolic changes as indicated by multi-parameter flow cytometry and traditional methods of fermentation profiling (O-2 uptake rate, CO2 evolution rate and optical density measurements). Induction...

  18. New technique for determination of long-lived radioisotopes, Iodine-129, using multiparameter coincidence spectrometry

    International Nuclear Information System (INIS)

    Hatsukawa, Yuichi; Oshima, Masumi; Toh, Yosuke; Shinohara, Nobuo; Kushita, Kosuke; Ueno, Takashi

    2003-01-01

    Multiparameter coincidence γ-ray spectrometry based on g-g coincidence is widely used in the field of nuclear structure studies, and has produced many successful results. In this study, feasibility of the method for neutron activation analysis of long lived iodine isotope, 129 I, was investigated. (author)

  19. Model-based dynamic multi-parameter method for peak power estimation of lithium-ion batteries

    NARCIS (Netherlands)

    Sun, F.; Xiong, R.; He, H.; Li, W.; Aussems, J.E.E.

    2012-01-01

    A model-based dynamic multi-parameter method for peak power estimation is proposed for batteries and battery management systems (BMSs) used in hybrid electric vehicles (HEVs). The available power must be accurately calculated in order to not damage the battery by over charging or over discharging or

  20. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  1. Active hydrothermal and non-active massive sulfide mound investigation using a new multiparameter chemical sensor

    Science.gov (United States)

    Han, C.; Wu, G.; Qin, H.; Wang, Z.

    2012-12-01

    Investigation of active hydrothermal mound as well as non-active massive sulfide mound are studied recently. However, there is still lack of in-situ detection method for the non-active massive sulfide mound. Even though Transient ElectroMagnetic (TEM) and Electric Self-potential (SP) methods are good, they both are labour, time and money cost work. We proposed a new multiparameter chemical sensor method to study the seafloor active hydrothermal mound as well as non-active massive sulfide mound. This sensor integrates Eh, S2- ions concentration and pH electrochemical electrodes together, and could found chemical change caused by the active hydrothermal vent, even weak chemical abnormalities by non-active massive sulfide hydrothermal mound which MARP and CTD sometimes cannot detect. In 2012, the 1st Leg of the Chinese 26th cruise, the multiparameter chemical sensor was carried out with the deepsea camera system over the Carlsberg Ridge in Indian Ocean by R/V DAYANGYIHAO. It was shown small Eh and S2- ions concentration abnormal around a site at Northwest Indian ridge. This site was also evidenced by the TV grab. In the 2nd Leg of the same cruise in June, this chemical sensor was carried out with TEM and SP survey system. The chemical abnormalities are matched very well with both TEM and SP survey results. The results show that the multiparameter chemical sensor method not only can detect active hydrothermal mound, but also can find the non-active massive sulfide hydrothermal mound.

  2. Monitoring the Dead Sea Region by Multi-Parameter Stations

    Science.gov (United States)

    Mohsen, A.; Weber, M. H.; Kottmeier, C.; Asch, G.

    2015-12-01

    The Dead Sea Region is an exceptional ecosystem whose seismic activity has influenced all facets of the development, from ground water availability to human evolution. Israelis, Palestinians and Jordanians living in the Dead Sea region are exposed to severe earthquake hazard. Repeatedly large earthquakes (e.g. 1927, magnitude 6.0; (Ambraseys, 2009)) shook the whole Dead Sea region proving that earthquake hazard knows no borders and damaging seismic events can strike anytime. Combined with the high vulnerability of cities in the region and with the enormous concentration of historical values this natural hazard results in an extreme earthquake risk. Thus, an integration of earthquake parameters at all scales (size and time) and their combination with data of infrastructure are needed with the specific aim of providing a state-of-the-art seismic hazard assessment for the Dead Sea region as well as a first quantitative estimate of vulnerability and risk. A strong motivation for our research is the lack of reliable multi-parameter ground-based geophysical information on earthquakes in the Dead Sea region. The proposed set up of a number of observatories with on-line data access will enable to derive the present-day seismicity and deformation pattern in the Dead Sea region. The first multi-parameter stations were installed in Jordan, Israel and Palestine for long-time monitoring. All partners will jointly use these locations. All stations will have an open data policy, with the Deutsches GeoForschungsZentrum (GFZ, Potsdam, Germany) providing the hard and software for real-time data transmission via satellite to Germany, where all partners can access the data via standard data protocols.

  3. On the performance of bioanalytical fluorescence correlation spectroscopy measurements in a multiparameter photon-counting microscope

    Energy Technology Data Exchange (ETDEWEB)

    Mazouchi, Amir; Liu Baoxu; Bahram, Abdullah [Department of Physics, Institute for Optical Sciences, University of Toronto, Toronto (Canada); Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. N., Mississauga, ON, L5L 1C6 (Canada); Gradinaru, Claudiu C., E-mail: claudiu.gradinaru@utoronto.ca [Department of Physics, Institute for Optical Sciences, University of Toronto, Toronto (Canada); Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. N., Mississauga, ON, L5L 1C6 (Canada)

    2011-02-28

    Fluorescence correlation spectroscopy (FCS) data acquisition and analysis routines were developed and implemented in a home-built, multiparameter photon-counting microscope. Laser excitation conditions were investigated for two representative fluorescent probes, Rhodamine110 and enhanced green fluorescent protein (EGFP). Reliable local concentrations and diffusion constants were obtained by fitting measured FCS curves, provided that the excitation intensity did not exceed 20% of the saturation level for each fluorophore. Accurate results were obtained from FCS measurements for sample concentrations varying from pM to {mu}M range, as well as for conditions of high background signals. These experimental constraints were found to be determined by characteristics of the detection system and by the saturation behavior of the fluorescent probes. These factors actually limit the average number of photons that can be collected from a single fluorophore passing through the detection volume. The versatility of our setup and the data analysis capabilities were tested by measuring the mobility of EGFP in the nucleus of Drosophila cells under conditions of high concentration and molecular crowding. As a bioanalytical application, we studied by FCS the binding affinity of a novel peptide-based drug to the cancer-regulating STAT3 protein and corroborated the results with fluorescence polarization analysis derived from the same photon data.

  4. Estimation of the crack propagation direction in a mixed-mode geometry via multi-parameter fracture criteria

    Czech Academy of Sciences Publication Activity Database

    Malíková, L.; Veselý, V.; Seitl, Stanislav

    2015-01-01

    Roč. 9, č. 33 (2015), s. 25-32 ISSN 1971-8993 Institutional support: RVO:68081723 Keywords : Near-crack-tip fields * Williams expansion * Crack propagation direction * Multi-parameter fracture criteria * Finite element analysis Subject RIV: JL - Materials Fatigue, Friction Mechanics

  5. Multi-parameter variational calculations for the (2+1)-dimensional U(1) lattice gauge theory and the XY model

    International Nuclear Information System (INIS)

    Heys, D.W.; Stump, D.R.

    1987-01-01

    Variational calculations are described that use multi-parameter trial wave functions for the U(1) lattice gauge theory in two space dimensions, and for the XY model. The trial functions are constructed as the exponential of a linear combination of states from the strong-coupling basis of the model, with the coefficients treated as variational parameters. The expectation of the hamiltonian is computed by the Monte Carlo method, using a reweighting technique to evaluate expectation values in finite patches of the parameter space. The trial function for the U(1) gauge theory involves six variational parameters, and its weak-coupling behaviour is in reasonable agreement with theoretical expectations. (orig.)

  6. Hydrometeor discrimination in melting layer using multiparameter airborne radar measurement

    Science.gov (United States)

    Kumagai, H.; Meneghini, R.; Kozu, T.

    1992-01-01

    Results from a multiparameter airborne radar/radiometer experiment (the Typhoon experiment) are presented. The experiment was conducted in the western Pacific with the NASA DC-8 aircraft, in which a dual-wavelength at X-band and Ka-band and dual-polarization at X-band radar was installed. The signatures of dBZ(X), dBZ(Ka), LDR (linear depolarization ratio) at X-band and DZ=dBZ(X)-dBZ(Ka) are discussed for the data obtained in the penetration of the typhoon Flo. With emphasis on discrimination of hydrometeor particles, some statistical features of the brightband in stratiform rain are discussed.

  7. Crack propagation direction in a mixed mode geometry estimated via multi-parameter fracture criteria

    Czech Academy of Sciences Publication Activity Database

    Malíková, L.; Veselý, V.; Seitl, Stanislav

    2016-01-01

    Roč. 89, AUG (2016), s. 99-107 ISSN 0142-1123. [International Conference on Characterisation of Crack Tip Fields /3./. Urbino, 20.04.2015-22.04.2015] Institutional support: RVO:68081723 Keywords : Near-crack-tip fields * Mixed mode * Crack propagation direction * Multi-parameter fracture criteria * Finite element analysis Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.899, year: 2016

  8. Multiparameter data acquisition and analysis system for capture gamma-ray studies

    International Nuclear Information System (INIS)

    Hejja, I.; Belgya, T.; Molnar, G.L.; Szepesvary, A.

    1997-01-01

    A PC-based multiparameter data acquisition system has been built for the Budapest neutron capture gamma-ray spectrometer. The hardware consists of a homemade multiplexer accommodating up to ten ADC inputs, a 64 kword histogram memory board and a National Instruments 32-bit DIO card, used for data acquisition and control, as well as a timer/scaler TIO card of the same company. The multiplexer inputs can be flexibly configured by means of programmable XILINX logic chips. The system is driven by a Pentium PC connected to the local Ethernet. (author)

  9. Probabilistic teleportation via multi-parameter measurements and partially entangled states

    Science.gov (United States)

    Wei, Jiahua; Shi, Lei; Han, Chen; Xu, Zhiyan; Zhu, Yu; Wang, Gang; Wu, Hao

    2018-04-01

    In this paper, a novel scheme for probabilistic teleportation is presented with multi-parameter measurements via a non-maximally entangled state. This is in contrast to the fact that the measurement kinds for quantum teleportation are usually particular in most previous schemes. The detail implementation producers for our proposal are given by using of appropriate local unitary operations. Moreover, the total success probability and classical information of this proposal are calculated. It is demonstrated that the success probability and classical cost would be changed with the multi-measurement parameters and the entanglement factor of quantum channel. Our scheme could enlarge the research range of probabilistic teleportation.

  10. Multi-parameters scanning in HTI media

    KAUST Repository

    Masmoudi, Nabil

    2014-08-05

    Building credible anisotropy models is crucial in imaging. One way to estimate anisotropy parameters is to relate them analytically to traveltime, which is challenging in inhomogeneous media. Using perturbation theory, we develop traveltime approximations for transversely isotropic media with horizontal symmetry axis (HTI) as explicit functions of the anellipticity parameter η and the symmetry axis azimuth ϕ in inhomogeneous background media. Specifically, our expansion assumes an inhomogeneous elliptically anisotropic background medium, which may be obtained from well information and stacking velocity analysis in HTI media. This formulation has advantages on two fronts: on one hand, it alleviates the computational complexity associated with solving the HTI eikonal equation, and on the other hand, it provides a mechanism to scan for the best fitting parameters η and ϕ without the need for repetitive modeling of traveltimes, because the traveltime coefficients of the expansion are independent of the perturbed parameters η and ϕ. The accuracy of our expansion is further enhanced by the use of shanks transform. We show the effectiveness of our scheme with tests on a 3D model and we propose an approach for multi-parameters scanning in TI media.

  11. Multi-parameters scanning in HTI media

    KAUST Repository

    Masmoudi, Nabil; Alkhalifah, Tariq Ali

    2014-01-01

    Building credible anisotropy models is crucial in imaging. One way to estimate anisotropy parameters is to relate them analytically to traveltime, which is challenging in inhomogeneous media. Using perturbation theory, we develop traveltime approximations for transversely isotropic media with horizontal symmetry axis (HTI) as explicit functions of the anellipticity parameter η and the symmetry axis azimuth ϕ in inhomogeneous background media. Specifically, our expansion assumes an inhomogeneous elliptically anisotropic background medium, which may be obtained from well information and stacking velocity analysis in HTI media. This formulation has advantages on two fronts: on one hand, it alleviates the computational complexity associated with solving the HTI eikonal equation, and on the other hand, it provides a mechanism to scan for the best fitting parameters η and ϕ without the need for repetitive modeling of traveltimes, because the traveltime coefficients of the expansion are independent of the perturbed parameters η and ϕ. The accuracy of our expansion is further enhanced by the use of shanks transform. We show the effectiveness of our scheme with tests on a 3D model and we propose an approach for multi-parameters scanning in TI media.

  12. Concept for a solid-state multi-parameter sensor system for cell-culture monitoring

    International Nuclear Information System (INIS)

    Baecker, M.; Beging, S.; Biselli, M.; Poghossian, A.; Wang, J.; Zang, W.; Wagner, P.; Schoening, M.J.

    2009-01-01

    In this study, a concept for a silicon-based modular solid-state sensor system for inline multi-parameter monitoring of cell-culture fermentation processes is presented. The envisaged multi-parameter sensor system consists of two identical sensor modules and is intended for continuous quantification of up to five (bio-)chemical and physical parameters, namely, glucose and glutamine concentration, pH value, electrolyte conductivity and temperature by applying different transducer principles and/or different operation modes. Experimental results for the field-effect electrolyte-insulator-semiconductor (EIS) sterilisable pH sensor and electrolyte conductivity sensor based on interdigitated electrodes are presented. The ongoing autoclaving does not have any significant impact on the pH-sensitive properties of a Ta 2 O 5 -gate EIS sensor. Even after 30 autoclaving cycles, the pH sensors show a clear pH response and nearly linear calibration curve with a slope of 57 ± 1 mV/pH. Additional scanning electron microscopy and ellipsometric investigations do not show any visible surface degradation or changes in the thickness of the pH-sensitive Ta 2 O 5 layer. The preliminary results demonstrate the suitability of the developed EIS sensor for an inline pH measurement during a fermentation process. In addition, interdigitated electrodes of different geometries serving as electrolyte conductivity sensor have been tested for measurements in relatively high ionic-strength solutions.

  13. A multiparameter chaos control method based on OGY approach

    International Nuclear Information System (INIS)

    Souza de Paula, Aline; Amorim Savi, Marcelo

    2009-01-01

    Chaos control is based on the richness of responses of chaotic behavior and may be understood as the use of tiny perturbations for the stabilization of a UPO embedded in a chaotic attractor. Since one of these UPO can provide better performance than others in a particular situation the use of chaos control can make this kind of behavior to be desirable in a variety of applications. The OGY method is a discrete technique that considers small perturbations promoted in the neighborhood of the desired orbit when the trajectory crosses a specific surface, such as a Poincare section. This contribution proposes a multiparameter semi-continuous method based on OGY approach in order to control chaotic behavior. Two different approaches are possible with this method: coupled approach, where all control parameters influences system dynamics although they are not active; and uncoupled approach that is a particular case where control parameters return to the reference value when they become passive parameters. As an application of the general formulation, it is investigated a two-parameter actuation of a nonlinear pendulum control employing coupled and uncoupled approaches. Analyses are carried out considering signals that are generated by numerical integration of the mathematical model using experimentally identified parameters. Results show that the procedure can be a good alternative for chaos control since it provides a more effective UPO stabilization than the classical single-parameter approach.

  14. Fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, W; Franz, N; Ziegler, G [Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet Physik; Hegewisch, S; Kunz, D; Maier, D; Lutter, R; Schoeffel, K; Stanzel, B [Muenchen Univ. (Germany, F.R.). Sektion Physik; Drescher, B [Hahn-Meitner-Institut fuer Kernforschung Berlin G.m.b.H. (Germany, F.R.)

    1982-03-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed.

  15. Multiparameter flow cytometry reveals myelodysplasia-related aberrant antigen expression in myelodysplastic/myeloproliferative neoplasms.

    Science.gov (United States)

    Kern, Wolfgang; Bacher, Ulrike; Schnittger, Susanne; Alpermann, Tamara; Haferlach, Claudia; Haferlach, Torsten

    2013-05-01

    Within the myelodysplastic/myeloproliferative neoplasm (MDS/MPN) category of the WHO (2008), only chronic myelomonocytic leukemia was so far evaluated by multiparameter flow cytometry (MFC). To investigate the potential of MFC for MDS/MPNs, unclassifiable (MDS/MPNu), and refractory anemia associated with ring sideroblasts and marked thrombocytosis (RARS-T), we studied 91 patients with these entities (60 males/31 females; 35.3-87.4 years) for MDS-related aberrant immunophenotypes (≥ 2 different cell lineages with ≥ 3 aberrantly expressed antigens). Data were correlated with cytomorphology and cytogenetics. MFC identified MDS-related immunophenotypes in 54/91 (59.3%) of patients. Patients with or without MDS-related immunophenotype did not differ significantly by demographic characteristics, blood values, or median overall survival. MDS-related immunophenotype cases showed a higher number of aberrantly expressed antigens (mean ± SD, 4.9 ± 2.4 vs. 2.0 ± 1.4; P MPNu and RARS-T. MFC therefore may be helpful to separate cases into more "MDS-like" or "MPN-like" subgroups. Copyright © 2012 International Clinical Cytometry Society.

  16. Combining wood anatomy and stable isotope variations in a 600-year multi-parameter climate reconstruction from Corsican black pine

    Science.gov (United States)

    Szymczak, Sonja; Hetzer, Timo; Bräuning, Achim; Joachimski, Michael M.; Leuschner, Hanns-Hubert; Kuhlemann, Joachim

    2014-10-01

    We present a new multi-parameter dataset from Corsican black pine growing on the island of Corsica in the Western Mediterranean basin covering the period AD 1410-2008. Wood parameters measured include tree-ring width, latewood width, earlywood width, cell lumen area, cell width, cell wall thickness, modelled wood density, as well as stable carbon and oxygen isotopes. We evaluated the relationships between different parameters and determined the value of the dataset for climate reconstructions. Correlation analyses revealed that carbon isotope ratios are influenced by cell parameters determining cell size, whereas oxygen isotope ratios are influenced by cell parameters determining the amount of transportable water in the xylem. A summer (June to August) precipitation reconstruction dating back to AD 1185 was established based on tree-ring width. No long-term trends or pronounced periods with extreme high/low precipitation are recorded in our reconstruction, indicating relatively stable moisture conditions over the entire time period. By comparing the precipitation reconstruction with a summer temperature reconstruction derived from the carbon isotope chronologies, we identified summers with extreme climate conditions, i.e. warm-dry, warm-wet, cold-dry and cold-wet. Extreme climate conditions during summer months were found to influence cell parameter characteristics. Cold-wet summers promote the production of broad latewood composed of wide and thin-walled tracheids, while warm-wet summers promote the production of latewood with small thick-walled cells. The presented dataset emphasizes the potential of multi-parameter wood analysis from one tree species over long time scales.

  17. Multi-parameter fibre Bragg grating sensor-array for thermal vacuum cycling test

    Science.gov (United States)

    Cheng, L.; Ahlers, B.; Toet, P.; Casarosa, G.; Appolloni, M.

    2017-11-01

    Fibre Bragg Grating (FBG) sensor systems based on optical fibres are gaining interest in space applications. Studies on Structural Health Monitoring (SHM) of the reusable launchers using FBG sensors have been carried out in the Future European Space Transportation Investigations Programme (FESTIP). Increasing investment in the development on FBG sensor applications is foreseen for the Future Launchers Preparatory Programme (FLPP). TNO has performed different SHM measurements with FBGs including on the VEGA interstage [1, 2] in 2006. Within the current project, a multi-parameter FBG sensor array demonstrator system for temperature and strain measurements is designed, fabricated and tested under ambient as well as Thermal Vacuum (TV) conditions in a TV chamber of the European Space Agency (ESA), ESTEC site. The aim is the development of a multi-parameters measuring system based on FBG technology for space applications. During the TV tests of a Space Craft (S/C) or its subsystems, thermal measurements, as well as strain measurements are needed by the engineers in order to verify their prediction and to validate their models. Because of the dimensions of the test specimen and the accuracy requested to the measurement, a large number of observation/measuring points are needed. Conventional sensor systems require a complex routing of the cables connecting the sensors to their acquisition unit. This will add extra weight to the construction under test. FBG sensors are potentially light-weight and can easily be multiplexed in an array configuration. The different tasks comply of a demonstrator system design; its component selection, procurement, manufacturing and finally its assembly. The temperature FBG sensor is calibrated in a dedicated laboratory setup down to liquid nitrogen (LN2) temperature at TNO. A temperature-wavelength calibration curve is generated. After a test programme definition a setup in thermal vacuum is realised at ESA premises including a mechanical

  18. Generalized synchronization-based multiparameter estimation in modulated time-delayed systems

    Science.gov (United States)

    Ghosh, Dibakar; Bhattacharyya, Bidyut K.

    2011-09-01

    We propose a nonlinear active observer based generalized synchronization scheme for multiparameter estimation in time-delayed systems with periodic time delay. A sufficient condition for parameter estimation is derived using Krasovskii-Lyapunov theory. The suggested tool proves to be globally and asymptotically stable by means of Krasovskii-Lyapunov method. With this effective method, parameter identification and generalized synchronization of modulated time-delayed systems with all the system parameters unknown, can be achieved simultaneously. We restrict our study for multiple parameter estimation in modulated time-delayed systems with single state variable only. Theoretical proof and numerical simulation demonstrate the effectiveness and feasibility of the proposed technique. The block diagram of electronic circuit for multiple time delay system shows that the method is easily applicable in practical communication problems.

  19. TeraTools: Multiparameter data acquisition software for the Windows 95/NT OS

    International Nuclear Information System (INIS)

    Piercey, R.B.

    1997-01-01

    TeraTools, a general purpose, multiparameter, data acquisition application for Windows 95NT is described. It is based on the Kmax architecture which has been used since 1986 on the Macintosh computer at numerous industrial, education, and research sites world-wide. TeraTools includes high-level support for industry-standard modular instrumentation; a built-in scripting language; drivers for commercially available interfaces; hooks for external code extensions; event file sorting and replay; and a full set of histogramming and display tools. The environment is scalable and may be applied to problems involving a few parameters or many parameters

  20. Multi-Parameter Estimation for Orthorhombic Media

    KAUST Repository

    Masmoudi, Nabil

    2015-08-19

    Building reliable anisotropy models is crucial in seismic modeling, imaging and full waveform inversion. However, estimating anisotropy parameters is often hampered by the trade off between inhomogeneity and anisotropy. For instance, one way to estimate the anisotropy parameters is to relate them analytically to traveltimes, which is challenging in inhomogeneous media. Using perturbation theory, we develop travel-time approximations for orthorhombic media as explicit functions of the anellipticity parameters η1, η2 and a parameter Δγ in inhomogeneous background media. Specifically, our expansion assumes inhomogeneous ellipsoidal anisotropic background model, which can be obtained from well information and stacking velocity analysis. This approach has two main advantages: in one hand, it provides a computationally efficient tool to solve the orthorhombic eikonal equation, on the other hand, it provides a mechanism to scan for the best fitting anisotropy parameters without the need for repetitive modeling of traveltimes, because the coefficients of the traveltime expansion are independent of the perturbed parameters. Furthermore, the coefficients of the traveltime expansion provide insights on the sensitivity of the traveltime with respect to the perturbed parameters. We show the accuracy of the traveltime approximations as well as an approach for multi-parameter scanning in orthorhombic media.

  1. Multi-Parameter Estimation for Orthorhombic Media

    KAUST Repository

    Masmoudi, Nabil; Alkhalifah, Tariq Ali

    2015-01-01

    Building reliable anisotropy models is crucial in seismic modeling, imaging and full waveform inversion. However, estimating anisotropy parameters is often hampered by the trade off between inhomogeneity and anisotropy. For instance, one way to estimate the anisotropy parameters is to relate them analytically to traveltimes, which is challenging in inhomogeneous media. Using perturbation theory, we develop travel-time approximations for orthorhombic media as explicit functions of the anellipticity parameters η1, η2 and a parameter Δγ in inhomogeneous background media. Specifically, our expansion assumes inhomogeneous ellipsoidal anisotropic background model, which can be obtained from well information and stacking velocity analysis. This approach has two main advantages: in one hand, it provides a computationally efficient tool to solve the orthorhombic eikonal equation, on the other hand, it provides a mechanism to scan for the best fitting anisotropy parameters without the need for repetitive modeling of traveltimes, because the coefficients of the traveltime expansion are independent of the perturbed parameters. Furthermore, the coefficients of the traveltime expansion provide insights on the sensitivity of the traveltime with respect to the perturbed parameters. We show the accuracy of the traveltime approximations as well as an approach for multi-parameter scanning in orthorhombic media.

  2. Multiparameter data acquisition system for spectroscopy

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Brown, G. V.; Hildebrandt, L.; Wong, K. L.; Ali, R.

    2001-01-01

    A powerful and versatile, simple to use multiparameter data acquisition system has been implemented for use in spectroscopy. In its standard configuration, the system can acquire signal from 16 time-to-digital converter channels, 16 analog-to-digital converter channels, and 12 scaler inputs. The system was put to use on the electron beam ion trap experiment to record the output from four position-sensitive proportional counters in two soft x-ray spectrometers together with the signal from an x-ray pulse height analyzer. Also recorded are the electron beam energy and the pulse height distribution of the proportional counters. All data are recorded as a function of time. Because the relevant parameters are recorded simultaneously, software gates instead of hardware gates are used to select the data of interest. This has led to a substantial cost saving over earlier data acquisition systems. Data are stored in binary or in ascii format for system-independent processing. The operation of the system is demonstrated in a measurement of the M-shell soft x-ray spectrum of gold. We used the system to record the 3--4 and 3--5 transitions of gold (Au 44+ --Au 51+ ) excited with a simulated Maxwellian with electron temperature of 2.5 keV

  3. Flow-cytometric identification of vinegars using a multi-parameter analysis optical detection module

    Science.gov (United States)

    Verschooten, T.; Ottevaere, H.; Vervaeke, M.; Van Erps, J.; Callewaert, M.; De Malsche, W.; Thienpont, H.

    2015-09-01

    We show a proof-of-concept demonstration of a multi-parameter analysis low-cost optical detection system for the flowcytometric identification of vinegars. This multi-parameter analysis system can simultaneously measure laser induced fluorescence, absorption and scattering excited by two time-multiplexed lasers of different wavelengths. To our knowledge no other polymer optofluidic chip based system offers more simultaneous measurements. The design of the optofluidic channels is aimed at countering the effects that viscous fingering, air bubbles, and emulsion samples can have on the correct operation of such a detection system. Unpredictable variations in viscosity and refractive index of the channel content can be turned into a source of information. The sample is excited by two laser diodes that are driven by custom made low-cost laser drivers. The optofluidic chip is built to be robust and easy to handle and is reproducible using hot embossing. We show a custom optomechanical holder for the optofluidic chip that ensures correct alignment and automatic connection to the external fluidic system. We show an experiment in which 92 samples of vinegar are measured. We are able to identify 9 different kinds of vinegar with an accuracy of 94%. Thus we show an alternative approach to the classic optical spectroscopy solution at a lowered. Furthermore, we have shown the possibility of predicting the viscosity and turbidity of vinegars with a goodness-of-fit R2 over 0.947.

  4. A reagentless real-time method for the multiparameter analysis of nanoparticles as a potential 'trigger' device

    Science.gov (United States)

    Carr, Bob; Knowles, John; Warren, Jeremy

    2008-10-01

    We describe the continuing development of a laser-based, light scattering detector system capable of detecting and analysing liquid-borne nanoparticles. Using a finely focussed and specially configured laser beam to illuminate a suspension of nanoparticles in a small (250ul) sample and videoing the Brownian motion of each and every particle in the detection zone should allow individual but simultaneous detection and measurement of particle size, scattered light intensity, electrophoretic mobility and, where applicable, shape asymmetry. This real-time, multi-parameter analysis capability offers the prospect of reagentlessly differentiating between different particle types within a complex sample of potentially high and variable background. Employing relatively low powered (50-100mW) laser diode modules and low resolution CCD arrays, each component could be run off battery power, allowing distributed/remote or personal deployment. Voltages needed for electrophoresis measurement s would be similarly low (e.g. 20V, low current) and 30second videos (exported at mobile/cell phone download speeds) analysed remotely. The potential of such low-cost technology as a field-deployable grid of remote, battery powered and reagentless, multi-parameter sensors for use as trigger devices is discussed.

  5. Readout Distance Enhancement of the Passive Wireless Multi-Parameter Sensing System Using a Repeater Coil

    Directory of Open Access Journals (Sweden)

    Lifeng Wang

    2018-01-01

    Full Text Available A repeater coil is used to extend the detection distance of a passive wireless multi-parameter sensing system. The passive wireless sensing system has the ability of simultaneously monitoring three parameters by using backscatter modulation together with channel multiplexing. Two different repeater coils are designed and fabricated for readout distance enhancement of the sensing system: one is a PCB (printed circuit board repeater coil, and the other is a copper wire repeater coil. Under the conditions of fixed voltage and adjustable voltage, the maximum readout distance of the sensing system with and without a repeater coil is measured. Experimental results show that larger power supply voltage can help further increase the readout distance. The maximum readout distance of the sensing system with a PCB repeater coil has been extended 2.3 times, and the one with a copper wire repeater coil has been extended 3 times. Theoretical analysis and experimental results both indicate that the high Q factor repeater coil can extend the readout distance more. With the copper wire repeater coil as well as a higher power supply voltage, the passive wireless multi-parameter sensing system finally achieves a maximum readout distance of 13.5 cm.

  6. A fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    International Nuclear Information System (INIS)

    Liebl, W.; Franz, N.; Ziegler, G.

    1982-01-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed. (orig.)

  7. Performance reliability prediction for thermal aging based on kalman filtering

    International Nuclear Information System (INIS)

    Ren Shuhong; Wen Zhenhua; Xue Fei; Zhao Wensheng

    2015-01-01

    The performance reliability of the nuclear power plant main pipeline that failed due to thermal aging was studied by the performance degradation theory. Firstly, through the data obtained from the accelerated thermal aging experiments, the degradation process of the impact strength and fracture toughness of austenitic stainless steel material of the main pipeline was analyzed. The time-varying performance degradation model based on the state space method was built, and the performance trends were predicted by using Kalman filtering. Then, the multi-parameter and real-time performance reliability prediction model for the main pipeline thermal aging was developed by considering the correlation between the impact properties and fracture toughness, and by using the stochastic process theory. Thus, the thermal aging performance reliability and reliability life of the main pipeline with multi-parameter were obtained, which provides the scientific basis for the optimization management of the aging maintenance decision making for nuclear power plant main pipelines. (authors)

  8. Quantitative ultrasound assessment of breast tumor response to chemotherapy using a multi-parameter approach.

    Science.gov (United States)

    Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad; Sadeghi-Naini, Ali; Tran, William; Trudeau, Maureen E; Pritchard, Kathleen; Ghandi, Sonal; Verma, Sunil; Czarnota, Gregory J

    2016-07-19

    This study demonstrated the ability of quantitative ultrasound (QUS) parameters in providing an early prediction of tumor response to neoadjuvant chemotherapy (NAC) in patients with locally advanced breast cancer (LABC). Using a 6-MHz array transducer, ultrasound radiofrequency (RF) data were collected from 58 LABC patients prior to NAC treatment and at weeks 1, 4, and 8 of their treatment, and prior to surgery. QUS parameters including midband fit (MBF), spectral slope (SS), spectral intercept (SI), spacing among scatterers (SAS), attenuation coefficient estimate (ACE), average scatterer diameter (ASD), and average acoustic concentration (AAC) were determined from the tumor region of interest. Ultrasound data were compared with the ultimate clinical and pathological response of the patient's tumor to treatment and patient recurrence-free survival. Multi-parameter discriminant analysis using the κ-nearest-neighbor classifier demonstrated that the best response classification could be achieved using the combination of MBF, SS, and SAS, with an accuracy of 60 ± 10% at week 1, 77 ± 8% at week 4 and 75 ± 6% at week 8. Furthermore, when the QUS measurements at each time (week) were combined with pre-treatment (week 0) QUS values, the classification accuracies improved (70 ± 9% at week 1, 80 ± 5% at week 4, and 81 ± 6% at week 8). Finally, the multi-parameter QUS model demonstrated a significant difference in survival rates of responding and non-responding patients at weeks 1 and 4 (p=0.035, and 0.027, respectively). This study demonstrated for the first time, using new parameters tested on relatively large patient cohort and leave-one-out classifier evaluation, that a hybrid QUS biomarker including MBF, SS, and SAS could, with relatively high sensitivity and specificity, detect the response of LABC tumors to NAC as early as after 4 weeks of therapy. The findings of this study also suggested that incorporating pre-treatment QUS parameters of a tumor improved the

  9. Multi-parameter approach to evaluate the timing of memory status after 17DD-YF primary vaccination.

    Science.gov (United States)

    Costa-Pereira, Christiane; Campi-Azevedo, Ana Carolina; Coelho-Dos-Reis, Jordana Grazziela; Peruhype-Magalhães, Vanessa; Araújo, Márcio Sobreira Silva; do Vale Antonelli, Lis Ribeiro; Fonseca, Cristina Toscano; Lemos, Jandira Aparecida; Malaquias, Luiz Cosme Cote; de Souza Gomes, Matheus; Rodrigues Amaral, Laurence; Rios, Maria; Chancey, Caren; Persi, Harold Richard; Pereira, Jorge Marcelo; de Sousa Maia, Maria de Lourdes; Freire, Marcos da Silva; Martins, Reinaldo de Menezes; Homma, Akira; Simões, Marisol; Yamamura, Anna Yoshida; Farias, Roberto Henrique Guedes; Romano, Alessandro Pecego Martins; Domingues, Carla Magda; Tauil, Pedro Luiz; Vasconcelos, Pedro Fernando Costa; Caldas, Iramaya Rodrigues; Camacho, Luiz Antônio; Teixeira-Carvalho, Andrea; Martins-Filho, Olindo Assis

    2018-06-01

    In this investigation, machine-enhanced techniques were applied to bring about scientific insights to identify a minimum set of phenotypic/functional memory-related biomarkers for post-vaccination follow-up upon yellow fever (YF) vaccination. For this purpose, memory status of circulating T-cells (Naïve/early-effector/Central-Memory/Effector-Memory) and B-cells (Naïve/non-Classical-Memory/Classical-Memory) along with the cytokine profile (IFN/TNF/IL-5/IL-10) were monitored before-NV(day0) and at distinct time-points after 17DD-YF primary vaccination-PV(day30-45); PV(year1-9) and PV(year10-11). A set of biomarkers (eEfCD4; EMCD4; CMCD19; EMCD8; IFNCD4; IL-5CD8; TNFCD4; IFNCD8; TNFCD8; IL-5CD19; IL-5CD4) were observed in PV(day30-45), but not in NV(day0), with most of them still observed in PV(year1-9). Deficiencies of phenotypic/functional biomarkers were observed in NV(day0), while total lack of memory-related attributes was observed in PV(year10-11), regardless of the age at primary vaccination. Venn-diagram analysis pre-selected 10 attributes (eEfCD4, EMCD4, CMCD19, EMCD8, IFNCD4, IL-5CD8, TNFCD4, IFNCD8, TNFCD8 and IL-5CD4), of which the overall mean presented moderate accuracy to discriminate PV(day30-45)&PV(year1-9) from NV(day0)&PV(year10-11). Multi-parameter approaches and decision-tree algorithms defined the EMCD8 and IL-5CD4 attributes as the top-two predictors with moderated performance. Together with the PRNT titers, the top-two biomarkers led to a resultant memory status observed in 80% and 51% of volunteers in PV(day30-45) and PV(year1-9), contrasting with 0% and 29% found in NV(day0) and PV(year10-11), respectively. The deficiency of memory-related attributes observed at PV(year10-11) underscores the conspicuous time-dependent decrease of resultant memory following17DD-YF primary vaccination that could be useful to monitor potential correlates of protection in areas under risk of YF transmission.

  10. Nanofluidic device for continuous multiparameter quality assurance of biologics.

    Science.gov (United States)

    Ko, Sung Hee; Chandra, Divya; Ouyang, Wei; Kwon, Taehong; Karande, Pankaj; Han, Jongyoon

    2017-08-01

    Process analytical technology (PAT) is critical for the manufacture of high-quality biologics as it enables continuous, real-time and on-line/at-line monitoring during biomanufacturing processes. The conventional analytical tools currently used have many restrictions to realizing the PAT of current and future biomanufacturing. Here we describe a nanofluidic device for the continuous monitoring of biologics' purity and bioactivity with high sensitivity, resolution and speed. Periodic and angled nanofilter arrays served as the molecular sieve structures to conduct a continuous size-based analysis of biologics. A multiparameter quality monitoring of three separate commercial biologic samples within 50 minutes has been demonstrated, with 20 µl of sample consumption, inclusive of dead volume in the reservoirs. Additionally, a proof-of-concept prototype system, which integrates an on-line sample-preparation system and the nanofluidic device, was demonstrated for at-line monitoring. Thus, the system is ideal for on-site monitoring, and the real-time quality assurance of biologics throughout the biomanufacturing processes.

  11. Truncated Gauss-Newton Implementation for Multi-Parameter Full Waveform Inversion

    Science.gov (United States)

    Liu, Y.; Yang, J.; Dong, L.; Wang, Y.

    2014-12-01

    Full waveform inversion (FWI) is a numerical optimization method which aims at minimizing the difference between the synthetic and recorded seismic data to obtain high resolution subsurface images. A practical implementation for FWI is the adjoint-state method (AD), in which the data residuals at receiver locations are simultaneously back-propagated to form the gradient. Scattering-integral method (SI) is an alternative way which is based on the explicit building of the sensitivity kernel (Fréchet derivative matrix). Although it is more memory-consuming, SI is more efficient than AD when the number of the sources is larger than the number of the receivers. To improve the convergence of FWI, the information carried out by the inverse Hessian operator is crucial. Taking account accurately of the effect of this operator in FWI can correct illumination deficits, reserve the amplitude of the subsurface parameters, and remove artifacts generated by multiple reflections. In multi-parameter FWI, the off-diagonal blocks of the Hessian operator reflect the coupling between different parameter classes. Therefore, incorporating its inverse could help to mitigate the trade-off effects. In this study, we focus on the truncated Gauss-Newton implementation for multi-parameter FWI. The model update is computed through a matrix-free conjugate gradient solution of the Newton linear system. Both the gradient and the Hessian-vector product are calculated using the SI approach instead of the first- and second-order AD. However, the gradient expressed by kernel-vector product is calculated through the accumulation of the decomposed vector-scalar products. Thus, it's not necessary to store the huge sensitivity matrix beforehand. We call this method the matrix decomposition approach (MD). And the Hessian-vector product is replaced by two kernel-vector products which are then calculated by the above MD. By this way, we don't need to solve two additional wave propagation problems as in the

  12. Multi-parameters monitoring during traditional Chinese medicine concentration process with near infrared spectroscopy and chemometrics

    Science.gov (United States)

    Liu, Ronghua; Sun, Qiaofeng; Hu, Tian; Li, Lian; Nie, Lei; Wang, Jiayue; Zhou, Wanhui; Zang, Hengchang

    2018-03-01

    As a powerful process analytical technology (PAT) tool, near infrared (NIR) spectroscopy has been widely used in real-time monitoring. In this study, NIR spectroscopy was applied to monitor multi-parameters of traditional Chinese medicine (TCM) Shenzhiling oral liquid during the concentration process to guarantee the quality of products. Five lab scale batches were employed to construct quantitative models to determine five chemical ingredients and physical change (samples density) during concentration process. The paeoniflorin, albiflorin, liquiritin and samples density were modeled by partial least square regression (PLSR), while the content of the glycyrrhizic acid and cinnamic acid were modeled by support vector machine regression (SVMR). Standard normal variate (SNV) and/or Savitzkye-Golay (SG) smoothing with derivative methods were adopted for spectra pretreatment. Variable selection methods including correlation coefficient (CC), competitive adaptive reweighted sampling (CARS) and interval partial least squares regression (iPLS) were performed for optimizing the models. The results indicated that NIR spectroscopy was an effective tool to successfully monitoring the concentration process of Shenzhiling oral liquid.

  13. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  14. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  15. A molecular informatics view on best practice in multi-parameter compound optimization.

    Science.gov (United States)

    Lusher, Scott J; McGuire, Ross; Azevedo, Rita; Boiten, Jan-Willem; van Schaik, Rene C; de Vlieg, Jacob

    2011-07-01

    The difference between biologically active molecules and drugs is that the latter balance an array of related and unrelated properties required for administration to patients. Inevitability, during optimization, some of these multiple factors will conflict. Although informatics has a crucial role in addressing the challenges of modern compound optimization, it is arguably still undervalued and underutilized. We present here some of the basic requirements of multi-parameter drug design, the crucial role of informatics and examples of favorable practice. The most crucial of these best practices are the need for informaticians to align their technologies and insights directly to discovery projects and for all scientists in drug discovery to become more proficient in the use of in silico methods. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    OpenAIRE

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-01-01

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between t...

  17. Updating Parameters for Volcanic Hazard Assessment Using Multi-parameter Monitoring Data Streams And Bayesian Belief Networks

    Science.gov (United States)

    Odbert, Henry; Aspinall, Willy

    2014-05-01

    Evidence-based hazard assessment at volcanoes assimilates knowledge about the physical processes of hazardous phenomena and observations that indicate the current state of a volcano. Incorporating both these lines of evidence can inform our belief about the likelihood (probability) and consequences (impact) of possible hazardous scenarios, forming a basis for formal quantitative hazard assessment. However, such evidence is often uncertain, indirect or incomplete. Approaches to volcano monitoring have advanced substantially in recent decades, increasing the variety and resolution of multi-parameter timeseries data recorded at volcanoes. Interpreting these multiple strands of parallel, partial evidence thus becomes increasingly complex. In practice, interpreting many timeseries requires an individual to be familiar with the idiosyncrasies of the volcano, monitoring techniques, configuration of recording instruments, observations from other datasets, and so on. In making such interpretations, an individual must consider how different volcanic processes may manifest as measureable observations, and then infer from the available data what can or cannot be deduced about those processes. We examine how parts of this process may be synthesised algorithmically using Bayesian inference. Bayesian Belief Networks (BBNs) use probability theory to treat and evaluate uncertainties in a rational and auditable scientific manner, but only to the extent warranted by the strength of the available evidence. The concept is a suitable framework for marshalling multiple strands of evidence (e.g. observations, model results and interpretations) and their associated uncertainties in a methodical manner. BBNs are usually implemented in graphical form and could be developed as a tool for near real-time, ongoing use in a volcano observatory, for example. We explore the application of BBNs in analysing volcanic data from the long-lived eruption at Soufriere Hills Volcano, Montserrat. We discuss

  18. Evaluation of Measurements Collected with Multi-Parameter Continuous Water-Quality Monitors in Selected Illinois Streams, 2001-03

    Science.gov (United States)

    Groschen, George E.; King, Robin B.

    2005-01-01

    Eight streams, representing a wide range of environmental and water-quality conditions across Illinois, were monitored from July 2001 to October 2003 for five water-quality parameters as part of a pilot study by the U.S. Geological Survey (USGS) in cooperation with the Illinois Environmental Protection Agency (IEPA). Continuous recording multi-parameter water-quality monitors were installed to collect data on water temperature, dissolved-oxygen concentrations, specific conductivity, pH, and turbidity. The monitors were near USGS streamflow-gaging stations where stage and streamflow are continuously recorded. During the study period, the data collected for these five parameters generally met the data-quality objectives established by the USGS and IEPA at all eight stations. A similar pilot study during this period for measurement of chlorophyll concentrations failed to achieve the data-quality objectives. Of all the sensors used, the temperature sensors provided the most accurate and reliable measurements (generally within ?5 percent of a calibrated thermometer reading). Signal adjustments and calibration of all other sensors are dependent upon an accurate and precise temperature measurement. The dissolved-oxygen sensors were the next most reliable during the study and were responsive to changing conditions and accurate at all eight stations. Specific conductivity was the third most accurate and reliable measurement collected from the multi-parameter monitors. Specific conductivity at the eight stations varied widely-from less than 40 microsiemens (?S) at Rayse Creek near Waltonville to greater than 3,500 ?S at Salt Creek at Western Springs. In individual streams, specific conductivity often changed quickly (greater than 25 percent in less than 3 hours) and the sensors generally provided good to excellent record of these variations at all stations. The widest range of specific-conductivity measurements was in Salt Creek at Western Springs in the Greater Chicago

  19. Multiparameter estimation with single photons—linearly-optically generated quantum entanglement beats the shotnoise limit

    Science.gov (United States)

    You, Chenglong; Adhikari, Sushovit; Chi, Yuxi; LaBorde, Margarite L.; Matyas, Corey T.; Zhang, Chenyu; Su, Zuen; Byrnes, Tim; Lu, Chaoyang; Dowling, Jonathan P.; Olson, Jonathan P.

    2017-12-01

    It was suggested in (Motes et al 2015 Phys. Rev. Lett. 114 170802) that optical networks with relatively inexpensive overheads—single photon Fock states, passive optical elements, and single photon detection—can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small (ncompute the quantum Cramér-Rao bound to show these networks can have a constant-factor quantum advantage in multi-parameter estimation for even large number of modes. Additionally, we provide a simplified measurement scheme using only single-photon (on-off) detectors that is capable of approximately obtaining this sensitivity for a small number of modes.

  20. Multi-parameter approximation of the stress field in a cracked body in the more distant surroundings of the crack tip

    Czech Academy of Sciences Publication Activity Database

    Veselý, V.; Sobek, J.; Frantík, P.; Seitl, Stanislav

    2016-01-01

    Roč. 89, AUG (2016), s. 20-35 ISSN 0142-1123. [International Conference on Characterisation of Crack Tip Fields /3./. Urbino, 20.04.2015-22.04.2015] Institutional support: RVO:68081723 Keywords : Crack-tip fields * Williams power series * Higher order terms * Stress field reconstruction * Multi-parameter approximation accuracy Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.899, year: 2016

  1. Multi-parameter Full-waveform Inversion for Acoustic VTI Medium with Surface Seismic Data

    Science.gov (United States)

    Cheng, X.; Jiao, K.; Sun, D.; Huang, W.; Vigh, D.

    2013-12-01

    Full-waveform Inversion (FWI) attracts wide attention recently in oil and gas industry as a new promising tool for high resolution subsurface velocity model building. While the traditional common image point gather based tomography method aims to focus post-migrated data in depth domain, FWI aims to directly fit the observed seismic waveform in either time or frequency domain. The inversion is performed iteratively by updating the velocity fields to reduce the difference between the observed and the simulated data. It has been shown the inversion is very sensitive to the starting velocity fields, and data with long offsets and low frequencies is crucial for the success of FWI to overcome this sensitivity. Considering the importance of data with long offsets and low frequencies, in most geologic environment, anisotropy is an unavoidable topic for FWI especially at long offsets, since anisotropy tends to have more pronounced effects on waves traveled for a great distance. In VTI medium, this means more horizontal velocity will be registered in middle-to-long offset data, while more vertical velocity will be registered in near-to-middle offset data. Up to date, most of real world applications of FWI still remain in isotropic medium, and only a few studies have been shown to account for anisotropy. And most of those studies only account for anisotropy in waveform simulation, but not invert for those anisotropy fields. Multi-parameter inversion for anisotropy fields, even in VTI medium, remains as a hot topic in the field. In this study, we develop a strategy for multi-parameter FWI for acoustic VTI medium with surface seismic data. Because surface seismic data is insensitivity to the delta fields, we decide to hold the delta fields unchanged during our inversion, and invert only for vertical velocity and epsilon fields. Through parameterization analysis and synthetic tests, we find that it is more feasible to invert for the parameterization as vertical and horizontal

  2. A multiparameter wearable physiologic monitoring system for space and terrestrial applications

    Science.gov (United States)

    Mundt, Carsten W.; Montgomery, Kevin N.; Udoh, Usen E.; Barker, Valerie N.; Thonier, Guillaume C.; Tellier, Arnaud M.; Ricks, Robert D.; Darling, Robert B.; Cagle, Yvonne D.; Cabrol, Nathalie A.; hide

    2005-01-01

    A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

  3. Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

    Science.gov (United States)

    Pappas, D.; Jeevarajan, A.; Anderson, M. M.

    2004-01-01

    Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could

  4. Multiparameter models in the management of the development of territories, taking into account the influence of hydrometeorological factors

    Science.gov (United States)

    Istomin, E. P.; Popov, N. N.; Sokolov, A. G.; Fokicheva, A. A.

    2018-01-01

    The article considers the geoinformation management of the territory as a way to manage the organizational and technical systems and territories distributed in space. The article describes the main factors for the development and implementation of management decisions, requirements for the territorial management system and the structure of knowledge and data. Mathematical one-parameter and multiparameter models of risk assessment of management decisions applied to the natural and climatic potential of the development of the territory were considered.

  5. Multiparameter Monitoring and Prevention of Fault-Slip Rock Burst

    Directory of Open Access Journals (Sweden)

    Shan-chao Hu

    2017-01-01

    Full Text Available Fault-slip rock burst is one type of the tectonic rock burst during mining. A detailed understanding of the precursory information of fault-slip rock burst and implementation of monitoring and early warning systems, as well as pressure relief measures, are essential to safety production in deep mines. This paper first establishes a mechanical model of stick-slip instability in fault-slip rock bursts and then reveals the failure characteristics of the instability. Then, change rule of mining-induced stress and microseismic signals before the occurrence of fault-slip rock burst are proposed, and multiparameter integrated early warning methods including mining-induced stress and energy are established. Finally, pressure relief methods targeting large-diameter boreholes and coal seam infusion are presented in accordance with the occurrence mechanism of fault-slip rock burst. The research results have been successfully applied in working faces 2310 of the Suncun Coal Mine, and the safety of the mine has been enhanced. These research results improve the theory of fault-slip rock burst mechanisms and provide the basis for prediction and forecasting, as well as pressure relief, of fault-slip rock bursts.

  6. Analysis of accuracy of Williams series approximation of stress field in cracked body – influence of area of interest around crack-tip on multi-parameter regression performance

    Directory of Open Access Journals (Sweden)

    J. Sobek

    2017-01-01

    Full Text Available A study on the accuracy of an approximation of the stress field in a cracked body is presented. Crack-tip stress tensor is expressed using the linear elastic fracture mechanics (LEFM theory in this work, more precisely via its multi-parameter formulation, i.e. by Williams power series (WPS. Determination of coefficients of terms of this series is performed using a least squares-based regression technique known as over-deterministic method (ODM for which results from finite element (FE method computation are usually taken as inputs. Main attention is paid to a detailed analysis of a suitable selection of FE nodes whose results serve as the inputs to the employed method. Two different ways of FE nodal selection are compared – nodes selected from the crack tip vicinity lying at a ring of a certain radius versus nodes selected more or less uniformly from a specified part of the test specimen body. Comparison of these approaches is made with the help of procedures developed by the authors which enable both the determination of the coefficients of terms of the analytical WPS approximation of the stress field based on the FE results and the backward reconstruction of the field (again using WPS from those determined terms’ coefficients/functions. The wedge-splitting test (WST specimen with a crack is taken as example for the study.

  7. Effective Kratzer and Coulomb potentials as limit cases of a multiparameter exponential-type potential

    Energy Technology Data Exchange (ETDEWEB)

    García-Ravelo, J., E-mail: g.ravelo@hotmail.com [Departamento de Física, Escuela Superior de Física y Matemáticas, Instituto Politécnico Nacional, Edificio 9, Unidad Profesional Adolfo López Mateos, México D.F., 07738 (Mexico); Menéndez, A.; García-Martínez, J. [Departamento de Física, Escuela Superior de Física y Matemáticas, Instituto Politécnico Nacional, Edificio 9, Unidad Profesional Adolfo López Mateos, México D.F., 07738 (Mexico); Schulze-Halberg, A. [Department of Mathematics and Actuarial Science and Department of Physics, Indiana University Northwest, 3400 Broadway, Gary, IN 46408 (United States)

    2014-06-13

    We show that the effective Kratzer and Coulomb potentials can be obtained by taking particular limits of a multiparameter exponential potential that was studied recently. Moreover, we demonstrate that the bound state solutions of the exponential potential reduce correctly to their well-known counterparts associated with the Kratzer and Coulomb potentials. As a byproduct, we obtain a new limit relation for the hypergeometric function. - Highlights: • Kratzer and Coulomb potentials are limit cases of an exponential-type potential. • From exact s-waves, approximate solutions for l-waves are obtained. • l-waves of the potential tend to the solutions of the Kratzer and Coulomb potentials. • A non-evident identity between hypergeometric functions is demonstrated.

  8. Effective Kratzer and Coulomb potentials as limit cases of a multiparameter exponential-type potential

    International Nuclear Information System (INIS)

    García-Ravelo, J.; Menéndez, A.; García-Martínez, J.; Schulze-Halberg, A.

    2014-01-01

    We show that the effective Kratzer and Coulomb potentials can be obtained by taking particular limits of a multiparameter exponential potential that was studied recently. Moreover, we demonstrate that the bound state solutions of the exponential potential reduce correctly to their well-known counterparts associated with the Kratzer and Coulomb potentials. As a byproduct, we obtain a new limit relation for the hypergeometric function. - Highlights: • Kratzer and Coulomb potentials are limit cases of an exponential-type potential. • From exact s-waves, approximate solutions for l-waves are obtained. • l-waves of the potential tend to the solutions of the Kratzer and Coulomb potentials. • A non-evident identity between hypergeometric functions is demonstrated

  9. Optoelectronic transport properties in amorphous/crystalline silicon solar cell heterojunctions measured by frequency-domain photocarrier radiometry: Multi-parameter measurement reliability and precision studies

    International Nuclear Information System (INIS)

    Zhang, Y.; Melnikov, A.; Mandelis, A.; Halliop, B.; Kherani, N. P.; Zhu, R.

    2015-01-01

    A theoretical one-dimensional two-layer linear photocarrier radiometry (PCR) model including the presence of effective interface carrier traps was used to evaluate the transport parameters of p-type hydrogenated amorphous silicon (a-Si:H) and n-type crystalline silicon (c-Si) passivated by an intrinsic hydrogenated amorphous silicon (i-layer) nanolayer. Several crystalline Si heterojunction structures were examined to investigate the influence of the i-layer thickness and the doping concentration of the a-Si:H layer. The experimental data of a series of heterojunction structures with intrinsic thin layers were fitted to PCR theory to gain insight into the transport properties of these devices. The quantitative multi-parameter results were studied with regard to measurement reliability (uniqueness) and precision using two independent computational best-fit programs. The considerable influence on the transport properties of the entire structure of two key parameters that can limit the performance of amorphous thin film solar cells, namely, the doping concentration of the a-Si:H layer and the i-layer thickness was demonstrated. It was shown that PCR can be applied to the non-destructive characterization of a-Si:H/c-Si heterojunction solar cells yielding reliable measurements of the key parameters

  10. Optoelectronic transport properties in amorphous/crystalline silicon solar cell heterojunctions measured by frequency-domain photocarrier radiometry: multi-parameter measurement reliability and precision studies.

    Science.gov (United States)

    Zhang, Y; Melnikov, A; Mandelis, A; Halliop, B; Kherani, N P; Zhu, R

    2015-03-01

    A theoretical one-dimensional two-layer linear photocarrier radiometry (PCR) model including the presence of effective interface carrier traps was used to evaluate the transport parameters of p-type hydrogenated amorphous silicon (a-Si:H) and n-type crystalline silicon (c-Si) passivated by an intrinsic hydrogenated amorphous silicon (i-layer) nanolayer. Several crystalline Si heterojunction structures were examined to investigate the influence of the i-layer thickness and the doping concentration of the a-Si:H layer. The experimental data of a series of heterojunction structures with intrinsic thin layers were fitted to PCR theory to gain insight into the transport properties of these devices. The quantitative multi-parameter results were studied with regard to measurement reliability (uniqueness) and precision using two independent computational best-fit programs. The considerable influence on the transport properties of the entire structure of two key parameters that can limit the performance of amorphous thin film solar cells, namely, the doping concentration of the a-Si:H layer and the i-layer thickness was demonstrated. It was shown that PCR can be applied to the non-destructive characterization of a-Si:H/c-Si heterojunction solar cells yielding reliable measurements of the key parameters.

  11. High speed acquisition of multiparameter data using a Macintosh IIcx

    Science.gov (United States)

    Berno, Anthony; Vogel, John S.; Caffee, Marc

    1991-05-01

    Accelerator mass spectrometry systems based on > 3 MV tandem accelerators often use multianode ionization detectors and/or time-of-flight detectors to identify individual isotopes through multiparameter analysis. A Macintosh IIcx has been programmed to collect AMS data from a CAMAC-implemented analyzer and to display the histogrammed individual parameters and a doubleparameter array. The computer-CAMAC connection is through a NuBus to CAMAC dataway interface which allows direct addressing to all functions and registers in the crate. Asynchronous data from the rare isotope are sorted into a CAMAC memory module by a list sequence controller. Isotope switching is controlled by a one-cycle timing generator. A rate-dependent amount of time is used to transfer the data from the memory module at the end of each timing cycle. The present configuration uses 10-75 ms for rates of 500-10000 cps. Parameter analysis occurs during the rest of the 520 ms data collection cycle. Completed measurements of the isotope concentrations of each sample are written to files which are compatible with standard Macintosh databases or other processing programs. The system is inexpensive and operates at speeds comparable to those obtainable using larger computers.

  12. Applicability and feasibility of systematic review for performing evidence-based risk assessment in food and feed safety

    DEFF Research Database (Denmark)

    Aiassa, E.; Higgins, J.P.T.; Frampton, G. K.

    2015-01-01

    for answering questions in health care, and can be implemented to minimise biases in food and feed safety risk assessment. However, no methodological frameworks exist for refining risk assessment multi-parameter models into questions suitable for systematic review, and use of meta-analysis to estimate all......Food and feed safety risk assessment uses multi-parameter models to evaluate the likelihood of adverse events associated with exposure to hazards in human health, plant health, animal health, animal welfare and the environment. Systematic review and meta-analysis are established methods...... parameters in the risk model. This approach to planning and prioritising systematic review seems to have useful implications for producing evidence-based food and feed safety risk assessment....

  13. An integrated environment monitoring system for underground coal mines--Wireless Sensor Network subsystem with multi-parameter monitoring.

    Science.gov (United States)

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-07-21

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.

  14. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    Science.gov (United States)

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-01-01

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037

  15. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2014-07-01

    Full Text Available Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs. We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.

  16. Multi-parameter Analysis and Inversion for Anisotropic Media Using the Scattering Integral Method

    KAUST Repository

    Djebbi, Ramzi

    2017-10-24

    The main goal in seismic exploration is to identify locations of hydrocarbons reservoirs and give insights on where to drill new wells. Therefore, estimating an Earth model that represents the right physics of the Earth\\'s subsurface is crucial in identifying these targets. Recent seismic data, with long offsets and wide azimuth features, are more sensitive to anisotropy. Accordingly, multiple anisotropic parameters need to be extracted from the recorded data on the surface to properly describe the model. I study the prospect of applying a scattering integral approach for multi-parameter inversion for a transversely isotropic model with a vertical axis of symmetry. I mainly analyze the sensitivity kernels to understand the sensitivity of seismic data to anisotropy parameters. Then, I use a frequency domain scattering integral approach to invert for the optimal parameterization. The scattering integral approach is based on the explicit computation of the sensitivity kernels. I present a new method to compute the traveltime sensitivity kernels for wave equation tomography using the unwrapped phase. I show that the new kernels are a better alternative to conventional cross-correlation/Rytov kernels. I also derive and analyze the sensitivity kernels for a transversely isotropic model with a vertical axis of symmetry. The kernels structure, for various opening/scattering angles, highlights the trade-off regions between the parameters. For a surface recorded data, I show that the normal move-out velocity vn, ƞ and δ parameterization is suitable for a simultaneous inversion of diving waves and reflections. Moreover, when seismic data is inverted hierarchically, the horizontal velocity vh, ƞ and ϵ is the parameterization with the least trade-off. In the frequency domain, the hierarchical inversion approach is naturally implemented using frequency continuation, which makes vh, ƞ and ϵ parameterization attractive. I formulate the multi-parameter inversion using the

  17. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    Science.gov (United States)

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  18. A Tool for Performance Modeling of Parallel Programs

    Directory of Open Access Journals (Sweden)

    J.A. González

    2003-01-01

    Full Text Available Current performance prediction analytical models try to characterize the performance behavior of actual machines through a small set of parameters. In practice, substantial deviations are observed. These differences are due to factors as memory hierarchies or network latency. A natural approach is to associate a different proportionality constant with each basic block, and analogously, to associate different latencies and bandwidths with each "communication block". Unfortunately, to use this approach implies that the evaluation of parameters must be done for each algorithm. This is a heavy task, implying experiment design, timing, statistics, pattern recognition and multi-parameter fitting algorithms. Software support is required. We present a compiler that takes as source a C program annotated with complexity formulas and produces as output an instrumented code. The trace files obtained from the execution of the resulting code are analyzed with an interactive interpreter, giving us, among other information, the values of those parameters.

  19. Multi-parameter in vitro toxicity testing of crizotinib, sunitinib, erlotinib, and nilotinib in human cardiomyocytes

    International Nuclear Information System (INIS)

    Doherty, Kimberly R.; Wappel, Robert L.; Talbert, Dominique R.; Trusk, Patricia B.; Moran, Diarmuid M.; Kramer, James W.; Brown, Arthur M.; Shell, Scott A.; Bacus, Sarah

    2013-01-01

    Tyrosine kinase inhibitors (TKi) have greatly improved the treatment and prognosis of multiple cancer types. However, unexpected cardiotoxicity has arisen in a subset of patients treated with these agents that was not wholly predicted by pre-clinical testing, which centers around animal toxicity studies and inhibition of the human Ether-à-go-go-Related Gene (hERG) channel. Therefore, we sought to determine whether a multi-parameter test panel assessing the effect of drug treatment on cellular, molecular, and electrophysiological endpoints could accurately predict cardiotoxicity. We examined how 4 FDA-approved TKi agents impacted cell viability, apoptosis, reactive oxygen species (ROS) generation, metabolic status, impedance, and ion channel function in human cardiomyocytes. The 3 drugs clinically associated with severe cardiac adverse events (crizotinib, sunitinib, nilotinib) all proved to be cardiotoxic in our in vitro tests while the relatively cardiac-safe drug erlotinib showed only minor changes in cardiac cell health. Crizotinib, an ALK/MET inhibitor, led to increased ROS production, caspase activation, cholesterol accumulation, disruption in cardiac cell beat rate, and blockage of ion channels. The multi-targeted TKi sunitinib showed decreased cardiomyocyte viability, AMPK inhibition, increased lipid accumulation, disrupted beat pattern, and hERG block. Nilotinib, a second generation Bcr-Abl inhibitor, led to increased ROS generation, caspase activation, hERG block, and an arrhythmic beat pattern. Thus, each drug showed a unique toxicity profile that may reflect the multiple mechanisms leading to cardiotoxicity. This study demonstrates that a multi-parameter approach can provide a robust characterization of drug-induced cardiomyocyte damage that can be leveraged to improve drug safety during early phase development. - Highlights: • TKi with known adverse effects show unique cardiotoxicity profiles in this panel. • Crizotinib increases ROS, apoptosis, and

  20. Multi-parameter decoupling and slope tracking control strategy of a large-scale high altitude environment simulation test cabin

    Directory of Open Access Journals (Sweden)

    Li Ke

    2014-12-01

    Full Text Available A large-scale high altitude environment simulation test cabin was developed to accurately control temperatures and pressures encountered at high altitudes. The system was developed to provide slope-tracking dynamic control of the temperature–pressure two-parameter and overcome the control difficulties inherent to a large inertia lag link with a complex control system which is composed of turbine refrigeration device, vacuum device and liquid nitrogen cooling device. The system includes multi-parameter decoupling of the cabin itself to avoid equipment damage of air refrigeration turbine caused by improper operation. Based on analysis of the dynamic characteristics and modeling for variations in temperature, pressure and rotation speed, an intelligent controller was implemented that includes decoupling and fuzzy arithmetic combined with an expert PID controller to control test parameters by decoupling and slope tracking control strategy. The control system employed centralized management in an open industrial ethernet architecture with an industrial computer at the core. The simulation and field debugging and running results show that this method can solve the problems of a poor anti-interference performance typical for a conventional PID and overshooting that can readily damage equipment. The steady-state characteristics meet the system requirements.

  1. Seismo-Geochemical Variations in SW Taiwan: Multi-Parameter Automatic Gas Monitoring Results

    Science.gov (United States)

    Yang, T. F.; Fu, C.-C.; Walia, V.; Chen, C.-H.; Chyi, L. L.; Liu, T.-K.; Song, S.-R.; Lee, M.; Lin, C.-W.; Lin, C.-C.

    2006-04-01

    Gas variations of many mud volcanoes and hot springs distributed along the tectonic sutures in southwestern Taiwan are considered to be sensitive to the earthquake activity. Therefore, a multi-parameter automatic gas station was built on the bank of one of the largest mud-pools at an active fault zone of southwestern Taiwan, for continuous monitoring of CO2, CH4, N2 and H2O, the major constituents of its bubbling gases. During the year round monitoring from October 2001 to October 2002, the gas composition, especially, CH4 and CO2, of the mud pool showed significant variations. Taking the CO2/CH4 ratio as the main indicator, anomalous variations can be recognized from a few days to a few weeks before earthquakes and correlated well with those with a local magnitude >4.0 and local intensities >2. It is concluded that the gas composition in the area is sensitive to the local crustal stress/strain and is worthy to conduct real-time monitoring for the seismo-geochemical precursors.

  2. Multi-parameter analysis for the technical and economic assessment of photovoltaic systems in the main European Union countries

    International Nuclear Information System (INIS)

    Bortolini, Marco; Gamberi, Mauro; Graziani, Alessandro; Mora, Cristina; Regattieri, Alberto

    2013-01-01

    Highlights: • Performance cost model assesses the feasibility and profitability of PV systems. • Multi-country and multi-parameter analysis of PV systems in the European Union area. • The impact of key technical, environmental, economic and financial data is assessed. • Germany, Italy and Spain present the most effective PV sector support strategies. • The rated power and energy self-consumption ratio affect PV plant profitability. - Abstract: In the last decades, the attention to solar energy as a renewable and nonpolluting energy source increased a lot through scientists, private and public institutions. Several efforts are made to increase the diffusion of such a source and to create the conditions making it competitive for the energy market. Particularly, for the photovoltaic (PV) sector, the module efficiency increase, manufacturing cost reduction and a strong public support, through favorable incentive schemes, generates a significant rise in the installed power, exceeding 40 GWp in 2010. Although the global trend of the PV sector is positive, differences among countries arise out of local peculiarities and evolutions in the national support policies. This paper investigates such issues focusing on the feasibility analysis of PV solar systems for eight relevant countries in the European Union area, i.e. France, Germany, Greece, Italy, Spain, The Netherlands, Turkey and United Kingdom. A multi-country and multi-parameter comparative analysis, based on the net present value and payback capital budget indices, allows to highlight the conditions most affecting the economic feasibility of PV systems. The national support strategies, along with the most relevant technical, environmental, economic and financial parameters, are the key features included and compared in the analysis. The major results deal with the conditions which make PV systems potentially profitable for each country and installation feature. The national support strategies to the PV

  3. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  4. A Multiparameter Thermal Conductivity Equation for 1,1-Difluoroethane (R152a) with an Optimized Functional Form

    Science.gov (United States)

    Scalabrin, G.; Marchi, P.; Finezzo, F.

    2006-11-01

    The application of an optimization technique to the available experimental data has led to the development of a new multiparameter equation λ = λ ( T,ρ ) for the representation of the thermal conductivity of 1,1-difluoroethane (R152a). The region of validity of the proposed equation covers the temperature range from 220 to 460 K and pressures up to 55 MPa, including the near-critical region. The average absolute deviation of the equation with respect to the selected 939 primary data points is 1.32%. The proposed equation represents therefore a significant improvement with respect to the literature conventional equation. The density value required by the equation is calculated at the chosen temperature and pressure conditions using a high accuracy equation of state for the fluid.

  5. Stability, performance and sensitivity analysis of I.I.D. jump linear systems

    Science.gov (United States)

    Chávez Fuentes, Jorge R.; González, Oscar R.; Gray, W. Steven

    2018-06-01

    This paper presents a symmetric Kronecker product analysis of independent and identically distributed jump linear systems to develop new, lower dimensional equations for the stability and performance analysis of this type of systems than what is currently available. In addition, new closed form expressions characterising multi-parameter relative sensitivity functions for performance metrics are introduced. The analysis technique is illustrated with a distributed fault-tolerant flight control example where the communication links are allowed to fail randomly.

  6. Aging evaluation of active components by using performance evaluation

    International Nuclear Information System (INIS)

    Jung, S. K.; Jin, T. E.; Kim, J. S.; Jung, I. S.; Kim, T. R.

    2003-01-01

    Risk analysis and performance evaluation methodology were applied to the aging evaluation of active components in the periodic safety review of Wolsung unit 1. We conclude that evaluation of performance is more effective to discriminate the aging degradation of active component than the evaluation of aging mechanism. It is essential to analyze the common cause failures of low performance components to evaluate the properness of present maintenance system. Past 10 years failure history is used for establishing the performance criteria. Past 2 years failure history is used for the evaluating the recent performance condition. We analyze the failure mode of the components to improve the maintenance system. Performance evaluation methodology is useful for the quantitative evaluation of aging degradation of active components. Analysis on the repeated failures can be useful for the feedback to maintenance plan and interval

  7. Investigating the fatigue behavior of grain-oriented Fe-3%Si steel sheets using magnet-optical Kerr microscopy and micromagnetic multiparameter, microstructure and stress analysis

    Directory of Open Access Journals (Sweden)

    Deldar Shayan

    2018-01-01

    Full Text Available Fatigue is considered as a reason for a significant number of mechanical failures of engineering materials. Conventionally, microstructural investigations along with stress-strain hysteresis measurements are performed to understand and characterize the fatigue behavior of metallic materials. Moreover, further physical data like temperature, electrical resistance and, in the case of ferromagnetic materials, magnetic properties can be used for a comprehensive characterization of fatigue process. The present work has employed Magneto-Optical Kerr Effect (MOKE microscope and Micromagnetic Multiparameter, Microstructure and stress Analysis (3MA system to illustrate magnetic domain structure and various intrinsic magnetic properties including magnetic Barkhausen noise (MBN of the investigated material. In order to investigate the influence of the mechanical deformation processes on the magnetic parameters, samples were produced out of the grain-oriented electrical steel sheets and were subjected to a tensile test as well as a cyclic strain increase load test with R = 0 at ambient temperature.

  8. Models of evaluation of public joint-stock property management

    Science.gov (United States)

    Yakupova, N. M.; Levachkova, S.; Absalyamova, S. G.; Kvon, G.

    2017-12-01

    The paper deals with the models of evaluation of performance of both the management company and the individual subsidiaries on the basis of a combination of elements and multi-parameter and target approaches. The article shows that due to the power of multi-dimensional and multi-directional indicators of financial and economic activity it is necessary to assess the degree of achievement of the objectives with the use of multivariate ordinal model as a set of indicators, ordered by growth so that the maintenance of this order on a long interval of time will ensure the effective functioning of the enterprise in the long term. It is shown that these models can be regarded as the monitoring tools of implementation of strategies and guide the justification effectiveness of implementation of management decisions.

  9. Creation of Novel Cores for β-Secretase (BACE-1) Inhibitors: A Multiparameter Lead Generation Strategy.

    Science.gov (United States)

    Viklund, Jenny; Kolmodin, Karin; Nordvall, Gunnar; Swahn, Britt-Marie; Svensson, Mats; Gravenfors, Ylva; Rahm, Fredrik

    2014-04-10

    In order to find optimal core structures as starting points for lead optimization, a multiparameter lead generation workflow was designed with the goal of finding BACE-1 inhibitors as a treatment for Alzheimer's disease. De novo design of core fragments was connected with three predictive in silico models addressing target affinity, permeability, and hERG activity, in order to guide synthesis. Taking advantage of an additive SAR, the prioritized cores were decorated with a few, well-characterized substituents from known BACE-1 inhibitors in order to allow for core-to-core comparisons. Prediction methods and analyses of how physicochemical properties of the core structures correlate to in vitro data are described. The syntheses and in vitro data of the test compounds are reported in a separate paper by Ginman et al. [J. Med. Chem. 2013, 56, 4181-4205]. The affinity predictions are described in detail by Roos et al. [J. Chem. Inf. 2014, DOI: 10.1021/ci400374z].

  10. 48 CFR 436.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. Preparation of performance evaluation reports. (a) In addition to the requirements of FAR 36.604, performance evaluation reports shall be prepared for indefinite-delivery type contracts...

  11. High spatial resolution distributed fiber system for multi-parameter sensing based on modulated pulses.

    Science.gov (United States)

    Zhang, Jingdong; Zhu, Tao; Zhou, Huan; Huang, Shihong; Liu, Min; Huang, Wei

    2016-11-28

    We demonstrate a cost-effective distributed fiber sensing system for the multi-parameter detection of the vibration, the temperature, and the strain by integrating phase-sensitive optical time domain reflectometry (φ-OTDR) and Brillouin optical time domain reflectometry (B-OTDR). Taking advantage of the fast changing property of the vibration and the static properties of the temperature and the strain, both the width and intensity of the laser pulses are modulated and injected into the single-mode sensing fiber proportionally, so that three concerned parameters can be extracted simultaneously by only one photo-detector and one data acquisition channel. A data processing method based on Gaussian window short time Fourier transform (G-STFT) is capable of achieving high spatial resolution in B-OTDR. The experimental results show that up to 4.8kHz vibration sensing with 3m spatial resolution at 10km standard single-mode fiber can be realized, as well as the distributed temperature and stress profiles along the same fiber with 80cm spatial resolution.

  12. High speed acquisition of multi-parameter data using a Macintosh II CX

    International Nuclear Information System (INIS)

    Berno, A.; Vogel, J.S.; Caffee, M.

    1990-08-01

    Accelerator mass spectrometry systems based on >3MV tandem accelerators often use multi-anode ionization detectors and/or time-of-flight detectors to identify individual isotopes through multi-parameter analysis. A Macintosh llcx has been programmed to collect AMS data from a CAMAC-implemented analyzer and to display the histogrammed individual parameters and a double-parameter array. The computer-CAMAC connection is through a Nu-Bus to CAMAC dataway interface which allows direct addressing to all functions and locations in the crate. The asynchronous data from counting the rare isotope is sorted into a CAMAC memory module by a list sequence controller. Isotope switching is controlled by a one-cycle timing generator. A rate-dependent amount of time is used to transfer the data from the memory module at the end of each timing cycle. The present configuration uses 10 to 75 ms for rates of 500--10000 cps. Parameter analysis occurs during the rest of the 520 ms data collection cycle. Completed measurements of the isotope concentrations of each sample are written to files which are compatible with standard Macintosh databases or other processing programs. The system is inexpensive and operates at speeds comparable to those obtainable using larger computers

  13. Multi-parameter actuation of a neutrally stable shell: a flexible gear-less motor.

    Science.gov (United States)

    Hamouche, W; Maurini, C; Vidoli, S; Vincenti, A

    2017-08-01

    We have designed and tested experimentally a morphing structure consisting of a neutrally stable thin cylindrical shell driven by a multi-parameter piezoelectric actuation. The shell is obtained by plastically deforming an initially flat copper disc, so as to induce large isotropic and almost uniform inelastic curvatures. Following the plastic deformation, in a perfectly isotropic system, the shell is theoretically neutrally stable, having a continuous set of stable cylindrical shapes corresponding to the rotation of the axis of maximal curvature. Small imperfections render the actual structure bistable, giving preferred orientations. A three-parameter piezoelectric actuation, exerted through micro-fibre-composite actuators, allows us to add a small perturbation to the plastic inelastic curvature and to control the direction of maximal curvature. This actuation law is designed through a geometrical analogy based on a fully nonlinear inextensible uniform-curvature shell model. We report on the fabrication, identification and experimental testing of a prototype and demonstrate the effectiveness of the piezoelectric actuators in controlling its shape. The resulting motion is an apparent rotation of the shell, controlled by the voltages as in a 'gear-less motor', which is, in reality, a precession of the axis of principal curvature.

  14. Multiparameter telemetry as a sensitive screening method to detect vaccine reactogenicity in mice.

    Directory of Open Access Journals (Sweden)

    Margarete Arras

    Full Text Available Refined vaccines and adjuvants are urgently needed to advance immunization against global infectious challenges such as HIV, hepatitis C, tuberculosis and malaria. Large-scale screening efforts are ongoing to identify adjuvants with improved efficacy profiles. Reactogenicity often represents a major hurdle to the clinical use of new substances. Yet, irrespective of its importance, this parameter has remained difficult to screen for, owing to a lack of sensitive small animal models with a capacity for high throughput testing. Here we report that continuous telemetric measurements of heart rate, heart rate variability, body core temperature and locomotor activity in laboratory mice readily unmasked systemic side-effects of vaccination, which went undetected by conventional observational assessment and clinical scoring. Even minor aberrations in homeostasis were readily detected, ranging from sympathetic activation over transient pyrogenic effects to reduced physical activity and apathy. Results in real-time combined with the potential of scalability and partial automation in the industrial context suggest multiparameter telemetry in laboratory mice as a first-line screen for vaccine reactogenicity. This may accelerate vaccine discovery in general and may further the success of vaccines in combating infectious disease and cancer.

  15. Multiparameter flow cytometric remission is the most relevant prognostic factor for multiple myeloma patients who undergo autologous stem cell transplantation

    Science.gov (United States)

    Paiva, Bruno; Vidriales, Maria-Belén; Cerveró, Jorge; Mateo, Gema; Pérez, Jose J.; Montalbán, Maria A.; Sureda, Anna; Montejano, Laura; Gutiérrez, Norma C.; de Coca, Alfonso García; de las Heras, Natalia; Mateos, Maria V.; López-Berges, Maria C.; García-Boyero, Raimundo; Galende, Josefina; Hernández, Jose; Palomera, Luis; Carrera, Dolores; Martínez, Rafael; de la Rubia, Javier; Martín, Alejandro; Bladé, Joan; Lahuerta, Juan J.; Orfao, Alberto

    2008-01-01

    Minimal residual disease (MRD) assessment is standard in many hematologic malignancies but is considered investigational in multiple myeloma (MM). We report a prospective analysis of the prognostic importance of MRD detection by multiparameter flow cytometry (MFC) in 295 newly diagnosed MM patients uniformly treated in the GEM2000 protocol VBMCP/VBAD induction plus autologous stem cell transplantation [ASCT]). MRD status by MFC was determined at day 100 after ASCT. Progression-free survival (PFS; median 71 vs 37 months, P < .001) and overall survival (OS; median not reached vs 89 months, P = .002) were longer in patients who were MRD negative versus MRD positive at day 100 after ASCT. Similar prognostic differentiation was seen in 147 patients who achieved immunofixation-negative complete response after ASCT. Moreover, MRD− immunofixation-negative (IFx−) patients and MRD− IFx+ patients had significantly longer PFS than MRD+ IFx− patients. Multivariate analysis identified MRD status by MFC at day 100 after ASCT as the most important independent prognostic factor for PFS (HR = 3.64, P = .002) and OS (HR = 2.02, P = .02). Our findings demonstrate the clinical importance of MRD evaluation by MFC, and illustrate the need for further refinement of MM re-sponse criteria. This trial is registered at http://clinicaltrials.gov under identifier NCT00560053. PMID:18669875

  16. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  17. 48 CFR 2936.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. (a) The HCA must establish procedures to evaluate architect-engineer contractor... reports must be made using Standard Form 1421, Performance Evaluation (Architect-Engineer) as prescribed...

  18. 48 CFR 236.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Performance evaluation... Architect-Engineer Services 236.604 Performance evaluation. (a) Preparation of performance reports. Use DD Form 2631, Performance Evaluation (Architect-Engineer), instead of SF 1421. (2) Prepare a separate...

  19. 13 CFR 304.4 - Performance evaluations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Performance evaluations. 304.4... ECONOMIC DEVELOPMENT DISTRICTS § 304.4 Performance evaluations. (a) EDA shall evaluate the management... of at least one (1) other District Organization in the performance evaluation on a cost-reimbursement...

  20. A miniaturized and integrated gel post platform for multiparameter PCR detection of herpes simplex viruses from raw genital swabs.

    Science.gov (United States)

    Manage, Dammika P; Lauzon, Jana; Atrazhev, Alexey; Morrissey, Yuen C; Edwards, Ann L; Stickel, Alexander J; Crabtree, H John; Pabbaraju, Kanti; Zahariadis, George; Yanow, Stephanie K; Pilarski, Linda M

    2012-05-07

    Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2-14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1-2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 μL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.

  1. 48 CFR 36.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Performance evaluation. 36.604 Section 36.604 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION SPECIAL... Performance evaluation. See 42.1502(f) for the requirements for preparing past performance evaluations for...

  2. Performance evaluation and financial market runs

    NARCIS (Netherlands)

    Wagner, W.B.

    2013-01-01

    This paper develops a model in which performance evaluation causes runs by fund managers and results in asset fire sales. Performance evaluation nonetheless is efficient as it disciplines managers. Optimal performance evaluation combines absolute and relative components in order to make runs less

  3. Performance Evaluations in Audit Firms

    DEFF Research Database (Denmark)

    Riise Johansen, Thomas; Christoffersen, Jeppe

    2017-01-01

    Previous research has only minimally examined the association between the behaviour and performance evaluations of individual auditors beyond the use of efficiency-focused evaluations. We examine the association between dysfunctional auditor behaviour and three evaluation foci: an efficiency focus......, a client focus and a quality focus. Our results, which are based on questionnaire responses from 196 auditors, demonstrate that an efficiency focus is not associated with dysfunctional behaviour. A client focus is found to be associated with dysfunctional behaviour. Finally, and perhaps most importantly......, our results show that it seems possible to limit dysfunctional behaviours through a quality focus in performance evaluations. Our results provide insights of use to practitioners and regulators on how performance evaluations may not only induce but also reduce dysfunctional auditor behaviours....

  4. USE OF MULTIPARAMETER ANALYSIS OF LABORATORY BIOMARKERS TO ASSESS RHEUMATOID ARTHRITIS ACTIVITY

    Directory of Open Access Journals (Sweden)

    A. A. Novikov

    2015-01-01

    Full Text Available The key component in the management of patients with rheumatoid arthritis (RA is regular control of RA activity. The quantitative assessment of a patient’s status allows the development of standardized indications for anti-rheumatic therapy.Objective: to identify the laboratory biomarkers able to reflect RA activity.Subjects and methods. Fifty-eight patients with RA and 30 age- and sex-matched healthy donors were examined. The patients were divided into high/moderate and mild disease activity groups according to DAS28. The serum concentrations of 30 biomarkers were measured using immunonephelometric assay, enzyme immunoassay, and xMAP technology.Results and discussion. Multivariate analysis could identify the factors mostly related to high/moderate RA activity according to DAS28, such as fibroblast growth factor-2, monocyte chemoattractant protein-1, interleukins (IL 1α, 6, and 15, and tumor necrosis factor-α and could create a prognostic model for RA activity assessment. ROC analysis has shown that this model has excellent diagnostic efficiency in differentiating high/moderate versus low RA activity.Conclusion. To create a subjective assessment-independent immunological multiparameter index of greater diagnostic accuracy than the laboratory parameters routinely used in clinical practice may be a qualitatively new step in assessing and monitoring RA activity.

  5. Dry Process Fuel Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-15

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  6. Dry Process Fuel Performance Evaluation

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  7. Licensee Performance Evaluation: Phase II

    International Nuclear Information System (INIS)

    Chakoff, H.E.; Speaker, D.M.; Thompson, S.R.; Cohen, S.C.

    1979-08-01

    This report details work performed during the second phase of a two-phase contract to develop methodology for Licensee Performance Evaluation. The Phase I report, NUREG/CR-0110 details initial efforts on the contract. The model developed in Phase I was used to evaluate nine additional facilities for this report. Performance indicators from noncompliance data were also evaluated. Methodology was developed employing the noncompliance indicators and used for 12 case studies. It was found that licensee event report indicators could be more easily identified and utilized than noncompliance indicators based on presently available data systems. However, noncompliance data, appropriately related to cause, could provide real insight into why performance was what it was

  8. Multiparameter Flowfield Measurements in High-Pressure, Cryogenic Environments Using Femtosecond Lasers

    Science.gov (United States)

    Burns, Ross A.; Danehy, Paul M.; Peters, Christopher J.

    2016-01-01

    Femtosecond laser electronic excitation tagging (FLEET) and Rayleigh scattering (RS) from a femtosecond laser are demonstrated in the NASA Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The measured signals from these techniques are examined for their thermodynamic dependencies in pure nitrogen. The FLEET signal intensity and signal lifetimes are found to scale primarily with the gas density, as does the RS signal. Several models are developed, which capture these physical behaviors. Notably, the FLEET and Rayleigh scattering intensities scale linearly with the flow density, while the FLEET signal decay rates are a more complex function of the thermodynamic state of the gas. The measurement of various flow properties are demonstrated using these techniques. While density was directly measured from the signal intensities and FLEET signal lifetime, temperature and pressure were measured using the simultaneous FLEET velocity measurements while assuming the flow had a constant total enthalpy. Measurements of density, temperature, and pressure from the FLEET signal are made with accuracies as high as 5.3 percent, 0.62 percent, and 6.2 percent, respectively, while precisions were approximately 10 percent, 0.26 percent, and 11 percent for these same quantities. Similar measurements of density from Rayleigh scattering showed an overall accuracy of 3.5 percent and a precision of 10.2 percent over a limited temperature range (T greater than 195 K). These measurements suggest a high degree of utility at using the femtosecond-laser based diagnostics for making multiparameter measurements in high-pressure, cryogenic environments such as large-scale TCT facilities.

  9. Application of fast procedures for the real-time processing of multi-parameter events in the γ-spectroscopy

    International Nuclear Information System (INIS)

    Hanewinkel, H.

    1984-01-01

    The construction of a new structurated data acquisition system at the Cologne tandem accelerator should contribute to the further development of the experimental methods in nuclear physics. For this fast procedures for the real-time processing and on-line data reduction of multi-parameter events were development and applied. These procedures allowed in connection with the whole analyzer system an effective processing of the occurring many-parametric data. By this work an important condition for the experimental application of the high-resolution γγ anti-Compton coincidence spectrometer OSIRIS, which is constructed in an collaboration with goups in Berlin, Bonn, and Julich, was created at the Cologne accelerator. The ensued analyzer system offers however also to all other users an extension of their experimental possibilities. The requirements and the structure of the analyzer system as well as the procedures developed and applied for this are described and compared with other procedures proposed in literature. (orig./HSI) [de

  10. Multiparameter monitoring of short-term earthquake precursors and its physical basis. Implementation in the Kamchatka region

    Directory of Open Access Journals (Sweden)

    Pulinets Sergey

    2016-01-01

    Full Text Available We apply experimental approach of the multiparameter monitoring of short-term earthquake precursors which reliability was confirmed by the Lithosphere-Atmosphere-Ionosphere Coupling (LAIC model created recently [1]. A key element of the model is the process of Ion induced Nucleation (IIN and formation of cluster ions occurring as a result of the ionization of near surface air layer by radon emanating from the Earth's crust within the earthquake preparation zone. This process is similar to the formation of droplet’s embryos for cloud formation under action of galactic cosmic rays. The consequence of this process is the generation of a number of precursors that can be divided into two groups: a thermal and meteorological, and b electromagnetic and ionospheric. We demonstrate elements of prospective monitoring of some strong earthquakes in Kamchatka region and statistical results for the Chemical potential correction parameter for more than 10 years of observations for earthquakes with M≥6. As some experimental attempt, the data of Kamchatka volcanoes monitoring will be demonstrated.

  11. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  12. Structural modeling of the production quality as a multidimensional object of measurement and control

    OpenAIRE

    Зубрецкая, Наталья Анатольевна

    2015-01-01

    The structural-analytical models of product quality as a multidimensional process of evaluation, measurement and control are developed. The product quality is represented as a multi-factor, multi-criteria and multi-parameter estimation object. This structural formalization of quality demonstrates the multidimensional qualities: comprehensiveness due to a set of environmental factors; multicriteriality due collectively evaluated quality criteria; multiparameter information models that describe...

  13. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  14. Performability Modelling Tools, Evaluation Techniques and Applications

    NARCIS (Netherlands)

    Haverkort, Boudewijn R.H.M.

    1990-01-01

    This thesis deals with three aspects of quantitative evaluation of fault-tolerant and distributed computer and communication systems: performability evaluation techniques, performability modelling tools, and performability modelling applications. Performability modelling is a relatively new

  15. 48 CFR 1252.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Performance evaluation....216-72 Performance evaluation plan. As prescribed in (TAR) 48 CFR 1216.406(b), insert the following clause: Performance Evaluation Plan (OCT 1994) (a) A Performance Evaluation Plan shall be unilaterally...

  16. NPP Krsko natural circulation performance evaluation

    International Nuclear Information System (INIS)

    Segon, Velimir; Bajs, Tomislav; Frogheri, Monica

    1999-01-01

    The present document deals with an evaluation of the natural circulation performance of the Krsko nuclear power plant. Two calculation have been performed using the NPP Krsko nodalization (both similar to the LOBI A2-77 natural circulation experiment) - the first with the present steam generators at NPP Krsko (Westinghouse, 18% plugged), the second with the future steam generators (Siemens, 0% plugged). The results were evaluated using the natural circulation flow map derived in /1/, and were compared to evaluate the influence of the new steam generators on the natural circulation performance. (author)

  17. Conductor gestures influence evaluations of ensemble performance.

    Science.gov (United States)

    Morrison, Steven J; Price, Harry E; Smedley, Eric M; Meals, Cory D

    2014-01-01

    Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor's gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance: articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and non-majors (N = 285) viewed sixteen 30 s performances and evaluated the quality of the ensemble's articulation, dynamics, technique, and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble's performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity.

  18. A novel staining protocol for multiparameter assessment of cell heterogeneity in Phormidium populations (cyanobacteria employing fluorescent dyes.

    Directory of Open Access Journals (Sweden)

    Daria Tashyreva

    Full Text Available Bacterial populations display high heterogeneity in viability and physiological activity at the single-cell level, especially under stressful conditions. We demonstrate a novel staining protocol for multiparameter assessment of individual cells in physiologically heterogeneous populations of cyanobacteria. The protocol employs fluorescent probes, i.e., redox dye 5-cyano-2,3-ditolyl tetrazolium chloride, 'dead cell' nucleic acid stain SYTOX Green, and DNA-specific fluorochrome 4',6-diamidino-2-phenylindole, combined with microscopy image analysis. Our method allows simultaneous estimates of cellular respiration activity, membrane and nucleoid integrity, and allows the detection of photosynthetic pigments fluorescence along with morphological observations. The staining protocol has been adjusted for, both, laboratory and natural populations of the genus Phormidium (Oscillatoriales, and tested on 4 field-collected samples and 12 laboratory strains of cyanobacteria. Based on the mentioned cellular functions we suggest classification of cells in cyanobacterial populations into four categories: (i active and intact; (ii injured but active; (iii metabolically inactive but intact; (iv inactive and injured, or dead.

  19. Importance Performance Analysis as a Trade Show Performance Evaluation and Benchmarking Tool

    OpenAIRE

    Tafesse, Wondwesen; Skallerud, Kåre; Korneliussen, Tor

    2010-01-01

    Author's accepted version (post-print). The purpose of this study is to introduce importance performance analysis as a trade show performance evaluation and benchmarking tool. Importance performance analysis considers exhibitors’ performance expectation and perceived performance in unison to evaluate and benchmark trade show performance. The present study uses data obtained from exhibitors of an international trade show to demonstrate how importance performance analysis can be used to eval...

  20. Conductor gestures influence evaluations of ensemble performance

    Directory of Open Access Journals (Sweden)

    Steven eMorrison

    2014-07-01

    Full Text Available Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor’s gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance, articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and nonmajors (N = 285 viewed sixteen 30-second performances and evaluated the quality of the ensemble’s articulation, dynamics, technique and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble’s performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity.

  1. 48 CFR 3052.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... CONTRACT CLAUSES Text of Provisions and Clauses 3052.216-72 Performance evaluation plan. As prescribed in... Evaluation Plan (DEC 2003) (a) A Performance Evaluation Plan shall be unilaterally established by the...

  2. 40 CFR 35.515 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.515 Section 35.515 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....515 Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional...

  3. Evaluation of high-performance computing software

    Energy Technology Data Exchange (ETDEWEB)

    Browne, S.; Dongarra, J. [Univ. of Tennessee, Knoxville, TN (United States); Rowan, T. [Oak Ridge National Lab., TN (United States)

    1996-12-31

    The absence of unbiased and up to date comparative evaluations of high-performance computing software complicates a user`s search for the appropriate software package. The National HPCC Software Exchange (NHSE) is attacking this problem using an approach that includes independent evaluations of software, incorporation of author and user feedback into the evaluations, and Web access to the evaluations. We are applying this approach to the Parallel Tools Library (PTLIB), a new software repository for parallel systems software and tools, and HPC-Netlib, a high performance branch of the Netlib mathematical software repository. Updating the evaluations with feed-back and making it available via the Web helps ensure accuracy and timeliness, and using independent reviewers produces unbiased comparative evaluations difficult to find elsewhere.

  4. 40 CFR 35.115 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.115 Section 35.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional Administrator will...

  5. Design and implementation of atmospheric multi-parameter sensor for UAVs

    Science.gov (United States)

    Yu, F.; Zhao, Y.; Chen, G.; Liu, Y.; Han, Y.

    2017-12-01

    With the rapid development of industry and the increase of cars in developing countries, air pollutants have caused a series of environmental issues such as haze and smog. However, air pollution is a process of surface-to-air mass exchange, and various kinds of atmospheric factors have close association with aerosol concentration, such as temperature, humidity, etc. Vertical distributions of aerosol in the region provide an important clue to reveal the exchange mechanism in the atmosphere between atmospheric boundary layer and troposphere. Among the various kinds of flying platforms, unmanned aerial vehicles (UAVs) shows more advantages in vertical measurement of aerosol owned to its flexibility and low cost. However, only few sensors could be mounted on the UAVs because of the limited size and power requirement. Here, a light-weight, low-power atmospheric multi-parameter sensor (AMPS) is proposed and could be mounted on several kinds of UAV platforms. The AMPS integrates multi-sensors, which are the laser aerosol particle sensor, the temperature probe, the humidity probe and the pressure probe, in order to simultaneously sample the vertical distribution characters of aerosol particle concentration, temperature, relative humidity and atmospheric pressure. The data from the sensors are synchronized by a proposed communication mechanism based on GPS. Several kinds of housing are designed to accommodate the different payload requirements of UAVs in size and weight. The experiments were carried out with AMPS mounted on three kinds of flying platforms. The results shows that the power consumption is less than 1.3 W, with relatively high accuracy in temperature (±0.1°C), relative humidity (±0.8%RH), PM2.5 (<20%) and PM10 (<20%). Vertical profiles of PM2.5 and PM10 concentrations were observed simultaneously by the AMPS three times every day in five days. The results revealed the significant correlation between the aerosol particle concentration and atmospheric

  6. 48 CFR 2936.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Evaluation of contractor... Construction 2936.201 Evaluation of contractor performance. The HCA must establish procedures to evaluate construction contractor performance and prepare performance reports as required by FAR 36.201. ...

  7. On the role of density and attenuation in three-dimensional multiparameter viscoacoustic VTI frequency-domain FWI: an OBC case study from the North Sea

    Science.gov (United States)

    Operto, S.; Miniussi, A.

    2018-06-01

    3-D frequency-domain full waveform inversion (FWI) is applied on North Sea wide-azimuth ocean-bottom cable data at low frequencies (≤10 Hz) to jointly update vertical wave speed, density and quality factor Q in the viscoacoustic VTI approximation. We assess whether density and Q should be viewed as proxy to absorb artefacts resulting from approximate wave physics or are valuable for interpretation in the presence of soft sediments and gas cloud. FWI is performed in the frequency domain to account for attenuation easily. Multiparameter frequency-domain FWI is efficiently performed with a few discrete frequencies following a multiscale frequency continuation. However, grouping a few frequencies during each multiscale step is necessary to mitigate acquisition footprint and match dispersive shallow guided waves. Q and density absorb a significant part of the acquisition footprint hence cleaning the velocity model from this pollution. Low Q perturbations correlate with low-velocity zones associated with soft sediments and gas cloud. However, the amplitudes of the Q perturbations show significant variations when the inversion tuning is modified. This dispersion in the Q reconstructions is however not passed on the velocity parameter suggesting that cross-talks between first-order kinematic and second-order dynamic parameters are limited. The density model shows a good match with a well log at shallow depths. Moreover, the impedance built a posteriori from the FWI velocity and density models shows a well-focused image with however local differences with the velocity model near the sea bed where density might have absorbed elastic effects. The FWI models are finally assessed against time-domain synthetic seismogram modelling performed with the same frequency-domain modelling engine used for FWI.

  8. 10 CFR 1045.9 - RD classification performance evaluation.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false RD classification performance evaluation. 1045.9 Section... classification performance evaluation. (a) Heads of agencies shall ensure that RD management officials and those... RD or FRD documents shall have their personnel performance evaluated with respect to classification...

  9. 48 CFR 2452.216-73 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Performance evaluation plan... 2452.216-73 Performance evaluation plan. As prescribed in 2416.406(e)(3), insert the following clause in all award fee contracts: Performance Evaluation Plan (AUG 1987) (a) The Government shall...

  10. Prediction of chemotherapy outcome in patients with metastatic soft tissue sarcomas based on dynamic FDG PET (dPET) and a multiparameter analysis

    International Nuclear Information System (INIS)

    Dimitrakopoulou-Strauss, Antonia; Strauss, Ludwig G.; Vasamiliette, Julie; Egerer, Gerlinde; Schmitt, Thomas; Kasper, Bernd; Haberkorn, Uwe

    2010-01-01

    Dynamic PET studies with 18 F-FDG were performed in patients with metastatic soft tissue sarcomas who received conventional chemotherapy with doxorubicin hydrochloride (Adriamycin) and ifosfamide (AI-G). The goal of the study was to evaluate the impact of full kinetic analysis and assess its value with regard to the therapy outcome based on survival data. The evaluation included 17 patients with 29 metastatic lesions of soft tissue sarcomas, who were treated with chemotherapy consisting of an AI-G regimen prior to high-dose chemotherapy and peripheral blood stem cell transplantation where applicable. Patients were examined prior to onset of therapy and after completion of the first cycle of AI-G. Restaging data (n = 17) based on Response Evaluation Criteria in Solid Tumors were available. Survival data (n = 14) served for reference. The following parameters were retrieved from the dynamic PET studies: standardized uptake value (SUV), fractal dimension, two-compartment model with computation of k1, k2, k3, k4 (unit: 1/min), the fractional blood volume and the FDG influx calculated according to Patlak. The mean SUV was 6.9 prior to therapy and 4.7 after one cycle. The mean influx was 0.066 prior to therapy in comparison to 0.058 after one cycle. We dichotomized the patients according to the median survival time of 320 days into response (n = 6) and non-response (n = 8). The mean SUV was 7.6 in the group of responders and 5.4 in the group of non-responders prior to therapy. Responders revealed a mean SUV of 3.8 after therapy as compared to 5.0 SUV for non-responders. We used discriminant analysis to classify the patients into the two response groups. The classification of the non-responders was generally higher (negative predictive value > 61%) than for the responders. Finally, the combined use of the four predictor variables, namely mean SUV and k1 of both studies led to the highest accuracy of 90% for both groups. The data demonstrate that only a multiparameter

  11. Performance Evaluation Model for Application Layer Firewalls.

    Science.gov (United States)

    Xuan, Shichang; Yang, Wu; Dong, Hui; Zhang, Jiangchuan

    2016-01-01

    Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers). Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  12. Performance Evaluation Model for Application Layer Firewalls.

    Directory of Open Access Journals (Sweden)

    Shichang Xuan

    Full Text Available Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers. Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  13. Global evaluation of nuclear infrastructure utilization scenarios (GENIUS)

    International Nuclear Information System (INIS)

    unzik-Gougar, Mary Lou; Juchau, Christopher A.; Pasamehmetoglu, Kemal; Wilson, Paul P.H.; Oliver, Kyle M.; Turinsky, Paul J.; Abdel-Khalik, Hany S.; Hays, Ross; Stover, Tracy E.

    2007-01-01

    A new and unique fuel cycle systems code has been developed. Need for this analysis tool was established via methodical development of technical functions and requirements followed by an evaluation of existing fuel cycle codes. As demonstrated by analysis of GNEP-type scenarios, the GENIUS code discretely tracks nuclear material from beginning to end of the fuel cycle and among any number of independent regions. Users can define scenarios starting with any/all existing reactors and fuel cycle facilities or with an ideal futuristic arrangement. Development and preliminary application of GENIUS capabilities in uncertainty analysis/propagation and multi-parameter optimization have also been accomplished. (authors)

  14. Laboratory performance evaluation reports for management

    International Nuclear Information System (INIS)

    Lindahl, P.C.; Hensley, J.E.; Bass, D.A.; Johnson, P.L.; Marr, J.J.; Streets, W.E.; Warren, S.W.; Newberry, R.W.

    1995-01-01

    In support of the US DOE's environmental restoration efforts, the Integrated Performance Evaluation Program (IPEP) was developed to produce laboratory performance evaluation reports for management. These reports will provide information necessary to allow DOE headquarters and field offices to determine whether or not contracted analytical laboratories have the capability to produce environmental data of the quality necessary for the remediation program. This document describes the management report

  15. Performance evaluation recommendations of nuclear power plants outdoor significant civil structures earthquake resistance. Performance evaluation examples

    International Nuclear Information System (INIS)

    2005-06-01

    The Japan Society of Civil Engineers has updated performance evaluation recommendations of nuclear power plants outdoor significant civil structures earthquake resistance in June 2005. Based on experimental and analytical considerations, analytical seismic models of soils for underground structures, effects of vertical motions on time-history dynamic analysis and shear fracture of reinforced concretes by cyclic loadings have been incorporated in new recommendations. This document shows outdoor civil structures earthquake resistance and endurance performance evaluation examples based on revised recommendations. (T. Tanaka)

  16. Performance evaluation of Central European companies

    Directory of Open Access Journals (Sweden)

    Petr Fiala

    2015-10-01

    Full Text Available The paper presents a modelling approach for performance comparison of Central European companies on three levels: country, industry, and company. The approach is based on Data Envelopment Analysis and Analytic Hierarchy Process. The proposed model consists of two basic sections. The first section estimates the importance of selected industries in the countries, whereas the second section evaluates the performance of companies within industries. The results of both sections are synthesized and finally the country performance is estimated. The evaluation is based on the data set resulting from a survey of companies from selected industries.

  17. Evaluating Nonclinical Performance of the Academic Pathologist

    Directory of Open Access Journals (Sweden)

    Austin Blackburn Wiles MD

    2018-02-01

    Full Text Available Academic pathologists perform clinical duties, as well as valuable nonclinical activities. Nonclinical activities may consist of research, teaching, and administrative management among many other important tasks. While clinical duties have many clear metrics to measure productivity, like the relative value units of Medicare reimbursement, nonclinical performance is often difficult to measure. Despite the difficulty of evaluating nonclinical activities, nonclinical productivity is used to determine promotion, funding, and inform professional evaluations of performance. In order to better evaluate the important nonclinical performance of academic pathologists, we present an evaluation system for leadership use. This system uses a Microsoft Excel workbook to provide academic pathologist respondents and reviewing leadership a transparent, easy-to-complete system that is both flexible and scalable. This system provides real-time feedback to academic pathologist respondents and a clear executive summary that allows for focused guidance of the respondent. This system may be adapted to fit practices of varying size, measure performance differently based on years of experience, and can work with many different institutional values.

  18. Revisiting Mutual Fund Performance Evaluation

    OpenAIRE

    Angelidis, Timotheos; Giamouridis, Daniel; Tessaromatis, Nikolaos

    2012-01-01

    Mutual fund manager excess performance should be measured relative to their self-reported benchmark rather than the return of a passive portfolio with the same risk characteristics. Ignoring the self-reported benchmark introduces biases in the measurement of stock selection and timing components of excess performance. We revisit baseline empirical evidence in mutual fund performance evaluation utilizing stock selection and timing measures that address these biases. We introduce a new factor e...

  19. PERFORMANCE EVALUATION: LITERATURE REVIEW AND TIME EVOLUTION.

    Directory of Open Access Journals (Sweden)

    Pintea Mirela-Oana

    2012-07-01

    Full Text Available Performance evaluation of an economic entity requires approaching several criteria, such as industry and economic entity type, managerial and entrepreneurial strategy, competitive environment, human and material resources available, using a system of appropriate performance indicators for this purpose.The exigencies of communication occurred on the growing number of phenomena that marked the global economy in recent decades (internationalization and relocation of business crises and turmoil in financial markets, demand performance measurement to be made in a comprehensive way by financial and non-financial criteria. Indicators are measures of performance used by management to measure, report and improve performance of the economic entity. The relationship between indicators and management is ensured by the existence of performance measurement systems. Studies to date indicate that economic entities using balanced performance measurement systems as a key management tool registered superior performance compared to entities not using such systems. This study attempts to address the issue of performance evaluation by presenting opinions of different authors concerning the process of performance measurement and to present, after revising the literature, the evolution of the performance evaluation systems. We tried to do this literature review because sustainable development and, therefore, globalization require new standards of performance that exceeds the economic field, both for domestic companies as well as international ones. So, these standards should be integrated into corporate strategy development to ensure sustainability of activities undertaken by harmonizing the economic, social and environmental objectives. To assess the performance of economic entities it is required that performance evaluation to be done with a balanced multidimensional system, including both financial ratios and non-financial indicators in order to reduce the limits of

  20. Performance Evaluation of Investment (Mutual Funds

    Directory of Open Access Journals (Sweden)

    Povilas Vyšniauskas

    2014-12-01

    Full Text Available The efficiency of an investment fund is one of the main components in evaluating the performance of the fund. This study seeks for introducing and comparing risk and performance evaluation ratios. The paper is aimed at testing the worked out ratios and at distinguishing between the best ones for the purpose of evaluating the performance of Lithuanian mutual funds. Scientific studies show that a standard deviation, alpha, beta, Sharpe and Treynor ratios are mostly employed for identifying the performance of mutual funds that are also compared with their benchmark index to establish if these funds are outperformed and if is it worth paying management fees to investment banks for managing mutual funds. Historical data were selected for the period from 2012-01-02 to 2013-10-15 analysing the prices of monthly funds. The paper points out the areas of a practical application of the proposed model for investment fund valuation, which may not only provide valuable outcomes for practitioners but also may inspire further research on this article.

  1. Supercapacitors Performance Evaluation

    OpenAIRE

    Zhang, S; Pan, N

    2015-01-01

    The performance of a supercapacitor can be characterized by a series of key parameters, including the cell capacitance, operating voltage, equivalent series resistance, power density, energy density, and time constant. To accurately measure these parameters, a variety of methods have been proposed and are used in academia and industry. As a result, some confusion has been caused due to the inconsistencies between different evaluation methods and practices. Such confusion hinders effective com...

  2. Performance evaluation of Louisiana superpave mixtures.

    Science.gov (United States)

    2008-12-01

    This report documents the performance of Louisiana Superpave mixtures through laboratory mechanistic tests, mixture : volumetric properties, gradation analysis, and early field performance. Thirty Superpave mixtures were evaluated in this : study. Fo...

  3. Probing Protein Multidimensional Conformational Fluctuations by Single-Molecule Multiparameter Photon Stamping Spectroscopy

    Science.gov (United States)

    2015-01-01

    Conformational motions of proteins are highly dynamic and intrinsically complex. To capture the temporal and spatial complexity of conformational motions and further to understand their roles in protein functions, an attempt is made to probe multidimensional conformational dynamics of proteins besides the typical one-dimensional FRET coordinate or the projected conformational motions on the one-dimensional FRET coordinate. T4 lysozyme hinge-bending motions between two domains along α-helix have been probed by single-molecule FRET. Nevertheless, the domain motions of T4 lysozyme are rather complex involving multiple coupled nuclear coordinates and most likely contain motions besides hinge-bending. It is highly likely that the multiple dimensional protein conformational motions beyond the typical enzymatic hinged-bending motions have profound impact on overall enzymatic functions. In this report, we have developed a single-molecule multiparameter photon stamping spectroscopy integrating fluorescence anisotropy, FRET, and fluorescence lifetime. This spectroscopic approach enables simultaneous observations of both FRET-related site-to-site conformational dynamics and molecular rotational (or orientational) motions of individual Cy3-Cy5 labeled T4 lysozyme molecules. We have further observed wide-distributed rotational flexibility along orientation coordinates by recording fluorescence anisotropy and simultaneously identified multiple intermediate conformational states along FRET coordinate by monitoring time-dependent donor lifetime, presenting a whole picture of multidimensional conformational dynamics in the process of T4 lysozyme open-close hinge-bending enzymatic turnover motions under enzymatic reaction conditions. By analyzing the autocorrelation functions of both lifetime and anisotropy trajectories, we have also observed the dynamic and static inhomogeneity of T4 lysozyme multidimensional conformational fluctuation dynamics, providing a fundamental

  4. 48 CFR 1552.209-76 - Contractor performance evaluations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Contractor performance... 1552.209-76 Contractor performance evaluations. As prescribed in section 1509.170-1, insert the following clause in all applicable solicitations and contracts. Contractor Performance Evaluations (OCT 2002...

  5. 48 CFR 8.406-7 - Contractor Performance Evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contractor Performance... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Federal Supply Schedules 8.406-7 Contractor Performance Evaluation. Ordering activities must prepare an evaluation of contractor performance for each...

  6. 48 CFR 1536.201 - Evaluation of contracting performance.

    Science.gov (United States)

    2010-10-01

    ... performance. 1536.201 Section 1536.201 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY... Contracting for Construction 1536.201 Evaluation of contracting performance. (a) The Contracting Officer will... will file the form in the contractor performance evaluation files which it maintains. (e) The Quality...

  7. Performance evaluation on aquatic product cold-chain logistics

    Directory of Open Access Journals (Sweden)

    Wenbing Wu

    2015-11-01

    Full Text Available Purpose: The requirements for high quality and diversification aquatic products are increasing with the improvement of Chinese living standard. However, the distribution between place of production and place of consumption are uneven, which results in large cold-chain logistics demand for aquatic products. At present, the low-level development of cold chain logistics has a bad impact on the circulation of aquatic products in China. So it is very urgent to develop cold-chain logistics in China. Design/methodology/approach: In order to do this, we apply performance evaluation, a well-known management tool, to study Chinese aquatic product cold-chain logistics. In this paper we first propose SISP(Subjects, Indexes, Standards, and Phases of performance evaluation model and ACSSN model(Aquatic product, Customer, Supply Chain, Society, and Node enterprises of supply chain for aquatic products cold-chain logistics performance evaluation. Then an ANP-Fuzzy method is proposed to evaluate the operational performance of Shandong Oriental Ocean Sci-Tech Co., Ltd. Furthermore, a system dynamic model is built to simulate the impact of temperature on the profits in aquatic products cold-chain sales section. Findings: We find out within a reasonable temperature range, lower temperature brings higher profit level. Also, performance improvement methods are proposed and the simulation of performance evaluation system is developed. Practical implications: Our findings can help to improve the level of aquatic product cold-chain logistics in China. Originality/value: The paper proposes the SISP (Subjects, Indexes, Standards, and Phases of performance evaluation model and ACSSN model (Aquatic product, Customer, Supply Chain, Society, and Node enterprises of supply chain for aquatic products cold-chain logistics performance evaluation.

  8. Fitter. The package for fitting a chosen theoretical multi-parameter function through a set of data points. Application to experimental data of the YuMO spectrometer. Version 2.1.0. Long write-up and user's guide

    International Nuclear Information System (INIS)

    Solov'ev, A.G.; Stadnik, A.V.; Islamov, A.N.; Kuklin, A.I.

    2008-01-01

    Fitter is a C++ program aimed to fit a chosen theoretical multi-parameter function through a set of data points. The method of fitting is chi-square minimization. Moreover, the robust fitting method can be applied to Fitter. Fitter was designed to be used for a small-angle neutron scattering data analysis. Respective theoretical models are implemented in it. Some commonly used models (Gaussian and polynomials) are also implemented for wider applicability

  9. On the role of density and attenuation in 3D multi-parameter visco-acoustic VTI frequency-domain FWI: an OBC case study from the North Sea

    Science.gov (United States)

    Operto, S.; Miniussi, A.

    2018-03-01

    Three-dimensional frequency-domain full waveform inversion (FWI) is applied on North Sea wide-azimuth ocean-bottom cable data at low frequencies (≤ 10 Hz) to jointly update vertical wavespeed, density and quality factor Q in the visco-acoustic VTI approximation. We assess whether density and Q should be viewed as proxy to absorb artefacts resulting from approximate wave physics or are valuable for interpretation in presence of saturated sediments and gas. FWI is performed in the frequency domain to account for attenuation easily. Multi-parameter frequency-domain FWI is efficiently performed with a few discrete frequencies following a multi-scale frequency continuation. However, grouping a few frequencies during each multi-scale step is necessary to mitigate acquisition footprint and match dispersive shallow guided waves. Q and density absorb a significant part of the acquisition footprint hence cleaning the velocity model from this pollution. Low Q perturbations correlate with low velocity zones associated with soft sediments and gas cloud. However, the amplitudes of the Q perturbations show significant variations when the inversion tuning is modified. This dispersion in the Q reconstructions is however not passed on the velocity parameter suggesting that cross-talks between first-order kinematic and second-order dynamic parameters are limited. The density model shows a good match with a well log at shallow depths. Moreover, the impedance built a posteriori from the FWI velocity and density models shows a well-focused image with however local differences with the velocity model near the sea bed where density might have absorbed elastic effects. The FWI models are finally assessed against time-domain synthetic seismogram modelling performed with the same frequency-domain modelling engine used for FWI.

  10. Evaluating Tourist Destination Performance: Expanding the Sustainability Concept

    Directory of Open Access Journals (Sweden)

    Wenbin Luo

    2018-02-01

    Full Text Available Performance evaluations are a critical tool in promoting the sustainability of tourist destinations. The literature shows a lack of consensus on basic terminology and definitions of destination performance. While research focuses on business efficiency, areas such as development effectiveness, social equality, and environmental integrity are still not well understood, even though these are salient elements of sustainable development. This paper provides a framework for evaluating destination performance under the 4E rubric of economy, efficiency, effectiveness, and environmental quality, which reflects a more holistic and effective destination performance. The information entropy weight method and a multi-factor comprehensive evaluation model are developed and applied to an international destination, Zhangjiajie, China, which was selected as a case study to test the framework developed. Results show that the economy, efficiency, effectiveness, and environmental quality aspects should be considered when evaluating tourism development performance. The empirical analysis shows that based on these criteria, Zhangjiajie’s destination performance improved measurably during the test period from 2005 to 2009. The results indicate that significant events, natural disasters, and financial crises influence performance most.

  11. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  12. Methodology for quantitative evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.

    1981-01-01

    Of various approaches that might be taken to the diagnostic performance evaluation problem, Receiver Operating Characteristic (ROC) analysis holds great promise. Further development of the methodology for a unified, objective, and meaningful approach to evaluating the usefulness of medical imaging procedures is done by consideration of statistical significance testing, optimal sequencing of correlated studies, and analysis of observer performance

  13. Building Leadership Talent through Performance Evaluation

    Science.gov (United States)

    Clifford, Matthew

    2015-01-01

    Most states and districts scramble to provide professional development to support principals, but "principal evaluation" is often lost amid competing priorities. Evaluation is an important method for supporting principal growth, communicating performance expectations to principals, and improving leadership practice. It provides leaders…

  14. Evaluation channel performance in multichannel environments

    NARCIS (Netherlands)

    Gensler, S.; Dekimpe, M.; Skiera, B.

    2007-01-01

    Evaluating channel performance is crucial for actively managing multiple sales channels, and requires understanding the customers' channel preferences. Two key components of channel performance are (i) the existing customers' intrinsic loyalty to a particular channel and (ii) the channel's ability

  15. Performance of a high sensitivity time-of-flight PET ring operating simultaneously within a 3T MR system

    International Nuclear Information System (INIS)

    Levin, Craig S; Jansen, Floris; Deller, Tim; Maramraju, Sri Harsha; Grant, Alex; Iagaru, Andrei

    2014-01-01

    A time-of-flight (TOF)-PET/MR research system installed at Stanford will be used to test the hypotheses that (a) it is possible to acquire simultaneous TOF-PET and 3T MR data while achieving uncompromised performance in both modalities and (b) simultaneous TOF-PET/MR is a tool for multi-parameter characterization of disease. In this paper we will describe the design as well as performance measurements both for the standalone PET ring, and with the two systems integrated. We will also show a selection of clinical images to compare the performance of the integrated TOF-PET/MR system with that of a state-of-the-art PET/CT system.

  16. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  17. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  18. Evaluating supplier quality performance using analytical hierarchy process

    Science.gov (United States)

    Kalimuthu Rajoo, Shanmugam Sundram; Kasim, Maznah Mat; Ahmad, Nazihah

    2013-09-01

    This paper elaborates the importance of evaluating supplier quality performance to an organization. Supplier quality performance evaluation reflects the actual performance of the supplier exhibited at customer's end. It is critical in enabling the organization to determine the area of improvement and thereafter works with supplier to close the gaps. Success of the customer partly depends on supplier's quality performance. Key criteria as quality, cost, delivery, technology support and customer service are categorized as main factors in contributing to supplier's quality performance. 18 suppliers' who were manufacturing automotive application parts evaluated in year 2010 using weight point system. There were few suppliers with common rating which led to common ranking observed by few suppliers'. Analytical Hierarchy Process (AHP), a user friendly decision making tool for complex and multi criteria problems was used to evaluate the supplier's quality performance challenging the weight point system that was used for 18 suppliers'. The consistency ratio was checked for criteria and sub-criteria. Final results of AHP obtained with no overlap ratings, therefore yielded a better decision making methodology as compared to weight point rating system.

  19. Research on Performance Evaluation by IDSS Based on AHP

    Directory of Open Access Journals (Sweden)

    Tang Xuelian

    2013-03-01

    Full Text Available Talent resource is the primary resource. There are two sides as the starting point and foothold in this paper. One is how to evaluate the performance of science and technology talents flow by IDSS (Intelligence Decision Supporting System. Another is how to guide the innovation work of science and technology according to the evaluation results. The evaluation index on performance system has hierarchical structure. So AHP (Analytic Hierarchy Process is applied to evaluate the performance. Evaluation model is established and illustrated by the cases in this paper. It can be seen that the flow of performance is influenced by the growth rate of important scientific and technological achievements. Furthermore, some constructive suggestions are given based on the results of evaluation.

  20. comparative performance evaluation of an existing and modified

    African Journals Online (AJOL)

    PROF. BARTH EKWEME

    and fan speeds of 2800 rpm as against the existing cylinder and fan speeds of 934 rpm. The performance evaluation for ... KEYWORDS: Acha, fonio, dehuller, performance evaluation, ... centrifugal force as a result of the rotation of the cylinder.

  1. Computer technique for evaluating collimator performance

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1975-01-01

    A computer program has been developed to theoretically evaluate the overall performance of collimators used with radioisotope scanners and γ cameras. The first step of the program involves the determination of the line spread function (LSF) and geometrical efficiency from the fundamental parameters of the collimator being evaluated. The working equations can be applied to any plane of interest. The resulting LSF is applied to subroutine computer programs which compute corresponding modulation transfer function and contrast efficiency functions. The latter function is then combined with appropriate geometrical efficiency data to determine the performance index function. The overall computer program allows one to predict from the physical parameters of the collimator alone how well the collimator will reproduce various sized spherical voids of activity in the image plane. The collimator performance program can be used to compare the performance of various collimator types, to study the effects of source depth on collimator performance, and to assist in the design of collimators. The theory of the collimator performance equation is discussed, a comparison between the experimental and theoretical LSF values is made, and examples of the application of the technique are presented

  2. An hierarchical approach to performance evaluation of expert systems

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Kavi, Srinu

    1985-01-01

    The number and size of expert systems is growing rapidly. Formal evaluation of these systems - which is not performed for many systems - increases the acceptability by the user community and hence their success. Hierarchical evaluation that had been conducted for computer systems is applied for expert system performance evaluation. Expert systems are also evaluated by treating them as software systems (or programs). This paper reports many of the basic concepts and ideas in the Performance Evaluation of Expert Systems Study being conducted at the University of Southwestern Louisiana.

  3. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  4. Operator performance evaluation using multi criteria decision making methods

    Science.gov (United States)

    Rani, Ruzanita Mat; Ismail, Wan Rosmanira; Razali, Siti Fatihah

    2014-06-01

    Operator performance evaluation is a very important operation in labor-intensive manufacturing industry because the company's productivity depends on the performance of its operators. The aims of operator performance evaluation are to give feedback to operators on their performance, to increase company's productivity and to identify strengths and weaknesses of each operator. In this paper, six multi criteria decision making methods; Analytical Hierarchy Process (AHP), fuzzy AHP (FAHP), ELECTRE, PROMETHEE II, Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and VlseKriterijumska Optimizacija I Kompromisno Resenje (VIKOR) are used to evaluate the operators' performance and to rank the operators. The performance evaluation is based on six main criteria; competency, experience and skill, teamwork and time punctuality, personal characteristics, capability and outcome. The study was conducted at one of the SME food manufacturing companies in Selangor. From the study, it is found that AHP and FAHP yielded the "outcome" criteria as the most important criteria. The results of operator performance evaluation showed that the same operator is ranked the first using all six methods.

  5. Port performance evaluation tool based on microsimulation model

    Directory of Open Access Journals (Sweden)

    Tsavalista Burhani Jzolanda

    2017-01-01

    Full Text Available As port performance is becoming correlative to national competitiveness, the issue of port performance evaluation has significantly raised. Port performances can simply be indicated by port service levels to the ship (e.g., throughput, waiting for berthing etc., as well as the utilization level of equipment and facilities within a certain period. The performances evaluation then can be used as a tool to develop related policies for improving the port’s performance to be more effective and efficient. However, the evaluation is frequently conducted based on deterministic approach, which hardly captures the nature variations of port parameters. Therefore, this paper presents a stochastic microsimulation model for investigating the impacts of port parameter variations to the port performances. The variations are derived from actual data in order to provide more realistic results. The model is further developed using MATLAB and Simulink based on the queuing theory.

  6. Performance Evaluation Of Behavioral Biometric Systems

    OpenAIRE

    Cherifi , Fouad; Hemery , Baptiste; Giot , Romain; Pasquet , Marc; Rosenberger , Christophe

    2009-01-01

    We present in this chapter an overview of techniques for the performance evaluation of behavioral biometric systems. The BioAPI standard that defines the architecture of a biometric system is presented in the first part of the chapter... The general methodology for the evaluation of biometric systems is given including statistical metrics, definition of benchmark databases and subjective evaluation. These considerations rely with the ISO/IEC19795-1 standard describing the biometric performanc...

  7. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Performance-Based Evaluation and School Librarians

    Science.gov (United States)

    Church, Audrey P.

    2015-01-01

    Evaluation of instructional personnel is standard procedure in our Pre-K-12 public schools, and its purpose is to document educator effectiveness. With Race to the Top and No Child Left Behind waivers, states are required to implement performance-based evaluations that demonstrate student academic progress. This three-year study describes the…

  9. Performance Evaluation and Modelling of Container Terminals

    Science.gov (United States)

    Venkatasubbaiah, K.; Rao, K. Narayana; Rao, M. Malleswara; Challa, Suresh

    2018-02-01

    The present paper evaluates and analyzes the performance of 28 container terminals of south East Asia through data envelopment analysis (DEA), principal component analysis (PCA) and hybrid method of DEA-PCA. DEA technique is utilized to identify efficient decision making unit (DMU)s and to rank DMUs in a peer appraisal mode. PCA is a multivariate statistical method to evaluate the performance of container terminals. In hybrid method, DEA is integrated with PCA to arrive the ranking of container terminals. Based on the composite ranking, performance modelling and optimization of container terminals is carried out through response surface methodology (RSM).

  10. 48 CFR 36.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Evaluation of contractor performance. 36.201 Section 36.201 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Contracting for Construction 36.201 Evaluation of contractor performance. See 42.1502(e) for the requirements...

  11. Conceptual Designs for the Performance Improvement of APR1400 SIT and Preliminary Performance Evaluation

    International Nuclear Information System (INIS)

    Chu, In-Cheol; Kwon, Tae-Soon; Song, Chul-Hwa

    2008-01-01

    Some evolutionary type PWRs such as APR1400 and APWR adopt advanced safety injection tank (SIT). The SIT of APR1400 has a fluidic device (FD) which passively controls ECC water injection flow rate into reactor coolant system during refill and reflood phases of LB-LOCA (i.e., a high injection flow rate during the refill phase and a low injection flow rate during the reflood phase). The benefit of the FD is the elimination of the function of low pressure safety injection pump from the safety injection system. The flow controlling performance of the APR1400 FD was evaluated using a prototypical full-scale test facility, called VAPER (Valve Performance Evaluation Rig). Even though the performance of the APR1400 FD satisfied major design and licensing requirements, further improvement of the performance is expected such as the extension of total injection period, the delay of nitrogen gas discharge. Several conceptual designs have been being drawn out in order to improve the performance of the APR1400 SIT. The performance of some designs was evaluated using a small scale SIT test rig. The present paper introduces some of the conceptual designs and shows the performance evaluation experimental results

  12. OpenCL Performance Evaluation on Modern Multicore CPUs

    Directory of Open Access Journals (Sweden)

    Joo Hwan Lee

    2015-01-01

    Full Text Available Utilizing heterogeneous platforms for computation has become a general trend, making the portability issue important. OpenCL (Open Computing Language serves this purpose by enabling portable execution on heterogeneous architectures. However, unpredictable performance variation on different platforms has become a burden for programmers who write OpenCL applications. This is especially true for conventional multicore CPUs, since the performance of general OpenCL applications on CPUs lags behind the performance of their counterparts written in the conventional parallel programming model for CPUs. In this paper, we evaluate the performance of OpenCL applications on out-of-order multicore CPUs from the architectural perspective. We evaluate OpenCL applications on various aspects, including API overhead, scheduling overhead, instruction-level parallelism, address space, data location, data locality, and vectorization, comparing OpenCL to conventional parallel programming models for CPUs. Our evaluation indicates unique performance characteristics of OpenCL applications and also provides insight into the optimization metrics for better performance on CPUs.

  13. NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric

    Science.gov (United States)

    Companies | Energy Systems Integration Facility | NREL NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric Companies NREL Evaluates Advanced Solar Inverter Performance for Hawaiian performance and impacts of today's advanced solar inverters, as well as proprietary feedback to the inverter

  14. Financial performance evaluation and bankruptcy prediction (failure1

    Directory of Open Access Journals (Sweden)

    Talal A. Al-Kassar, Dr.

    2014-10-01

    The research also demonstrates the need to include measures of both financial and non-financial performance in the evaluation as they complement each other. Without both financial and non-financial, the evaluation process is incomplete and does not provide desired results or the correct image of the process. The research suggests including comprehensive measures of performance evaluation of projects by using indicators of adopted criteria. Thus, the application of both models leads to better results and assists users in maintaining greater objectivity while obtaining more accurate results than from analysis based on personal evaluation alone.

  15. Performance of MarSite Multi parameter Borehole Instrumentation

    Science.gov (United States)

    Guralp, Cansun; Tunc, Suleyman; Ozel, Oguz; Meral Ozel, Nurcan; Necmioglu, Ocal

    2017-04-01

    In this paper we present two year results obtained from the integrated multiparameter borehole system at Marsite. The very broad band (VBB) system have been operating since installation in November 2014; one year in a water filled borehole and one year in a dry Borehole. from January 2016. The real time data has been available to the community. The two Borehole environments are compared showing the superior performance of dry borehole environ- ment compared to water filled for a very broad band (VBB) seismometer. The practical considerations applied in both borehole installations are compared and the best borehole practical installation techniques are presented and discussed. The data is also compared with a surface 120 second broad band sensor and the seismic arrays with in MarSite region. The very long term performance, (one year data in a dry hole) of the VBB Borehole seismometer and the Dilatometer will be presented The high frequency performance of the VBB seismometer which extends to 150 Hz and the dilatometer are compared characterizing the results from the dilatometer.

  16. Model Performance Evaluation and Scenario Analysis (MPESA)

    Science.gov (United States)

    Model Performance Evaluation and Scenario Analysis (MPESA) assesses the performance with which models predict time series data. The tool was developed Hydrological Simulation Program-Fortran (HSPF) and the Stormwater Management Model (SWMM)

  17. Simulated Evaluation of Drug-Impaired Psychomotor Performance

    OpenAIRE

    Richmond R

    2014-01-01

    The purpose of this placebo-controlled, randomized-crossover study was to evaluate a computer-based divided-attention task as a method for measure impaired human psychomotor performance. The ability of the divided-attention task to detect and differentiate was evaluated using single oral doses of placebo, caffeine and diphenhydramine. Ten healthy men were the subjects of the study. Subject performance on divided-attention was compared with tests of short-term memory and a set of visual analog...

  18. Performance evaluation methodology for historical document image binarization.

    Science.gov (United States)

    Ntirogiannis, Konstantinos; Gatos, Basilis; Pratikakis, Ioannis

    2013-02-01

    Document image binarization is of great importance in the document image analysis and recognition pipeline since it affects further stages of the recognition process. The evaluation of a binarization method aids in studying its algorithmic behavior, as well as verifying its effectiveness, by providing qualitative and quantitative indication of its performance. This paper addresses a pixel-based binarization evaluation methodology for historical handwritten/machine-printed document images. In the proposed evaluation scheme, the recall and precision evaluation measures are properly modified using a weighting scheme that diminishes any potential evaluation bias. Additional performance metrics of the proposed evaluation scheme consist of the percentage rates of broken and missed text, false alarms, background noise, character enlargement, and merging. Several experiments conducted in comparison with other pixel-based evaluation measures demonstrate the validity of the proposed evaluation scheme.

  19. Who Should Evaluate Teachers' Performance at Schools?

    Science.gov (United States)

    Tabancali, Erkan

    2017-01-01

    Correct determination of whether or not the objectives are achieved or of the level of achievement of the objectives is vital in educational organizations. In this context, one of the indicators of how teachers serve the organizational objectives is performance evaluation. In Turkish Educational System, the evaluation of the performance of…

  20. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    Science.gov (United States)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  1. How the Brain Converts Negative Evaluation into Performance Facilitation.

    Science.gov (United States)

    Prévost, Charlotte; Lau, Hakwan; Mobbs, Dean

    2018-02-01

    Surpassing negative evaluation is a recurrent theme of success stories. Yet, there is little evidence supporting the counterintuitive idea that negative evaluation might not only motivate people, but also enhance performance. To address this question, we designed a task that required participants to decide whether taking up a risky challenge after receiving positive or negative evaluations from independent judges. Participants believed that these evaluations were based on their prior performance on a related task. Results showed that negative evaluation caused a facilitation in performance. Concurrent functional magnetic resonance imaging revealed that the motivating effect of negative evaluation was represented in the insula and striatum, while the performance boost was associated with functional positive connectivity between the insula and a set of brain regions involved in goal-directed behavior and the orienting of attention. These findings provide new insight into the neural representation of negative evaluation-induced facilitation. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. More on the losses of dissolved CO(2) during champagne serving: toward a multiparameter modeling.

    Science.gov (United States)

    Liger-Belair, Gérard; Parmentier, Maryline; Cilindre, Clara

    2012-11-28

    Pouring champagne into a glass is far from being inconsequential with regard to the dissolved CO(2) concentration found in champagne. Three distinct bottle types, namely, a magnum bottle, a standard bottle, and a half bottle, were examined with regard to their loss of dissolved CO(2) during the service of successively poured flutes. Whatever the bottle size, a decreasing trend is clearly observed with regard to the concentration of dissolved CO(2) found within a flute (from the first to the last one of a whole service). Moreover, when it comes to champagne serving, the bottle size definitely does matter. The higher the bottle volume, the better its buffering capacity with regard to dissolved CO(2) found within champagne during the pouring process. Actually, for a given flute number in a pouring data series, the concentration of dissolved CO(2) found within the flute was found to decrease as the bottle size decreases. The impact of champagne temperature (at 4, 12, and 20 °C) on the losses of dissolved CO(2) found in successively poured flutes for a given standard 75 cL bottle was also examined. Cold temperatures were found to limit the decreasing trend of dissolved CO(2) found within the successively poured flutes (from the first to the last one of a whole service). Our experimental results were discussed on the basis of a multiparameter model that accounts for the major physical parameters that influence the loss of dissolved CO(2) during the service of a whole bottle type.

  3. Behavioral patterns of environmental performance evaluation programs.

    Science.gov (United States)

    Li, Wanxin; Mauerhofer, Volker

    2016-11-01

    During the past decades numerous environmental performance evaluation programs have been developed and implemented on different geographic scales. This paper develops a taxonomy of environmental management behavioral patterns in order to provide a practical comparison tool for environmental performance evaluation programs. Ten such programs purposively selected are mapped against the identified four behavioral patterns in the form of diagnosis, negotiation, learning, and socialization and learning. Overall, we found that schemes which serve to diagnose environmental abnormalities are mainly externally imposed and have been developed as a result of technical debates concerning data sources, methodology and ranking criteria. Learning oriented scheme is featured by processes through which free exchange of ideas, mutual and adaptive learning can occur. Scheme developed by higher authority for influencing behaviors of lower levels of government has been adopted by the evaluated to signal their excellent environmental performance. The socializing and learning classified evaluation schemes have incorporated dialogue, participation, and capacity building in program design. In conclusion we consider the 'fitness for purpose' of the various schemes, the merits of our analytical model and the future possibilities of fostering capacity building in the realm of wicked environmental challenges. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Virginia power's human performance evaluation system (HPES)

    International Nuclear Information System (INIS)

    Patterson, W.E.

    1991-01-01

    This paper reports on the Human Performance Evaluation System (HPES) which was initially developed by the Institute of Nuclear Power Operations (INPO) using the Aviation Safety Reporting System (ASRS) as a guide. After a pilot program involving three utilities ended in 1983, the present day program was instituted. A methodology was developed, for specific application to nuclear power plant employees, to aid trained coordinators/evaluators in determining those factors that exert a negative influence on human behavior in the nuclear power plant environment. HPES is for anyone and everyone on site, from contractors to plant staff to plant management. No one is excluded from participation. Virginia Power's HPES program goal is to identify and correct the root causes of human performance problems. Evaluations are performed on reported real or perceived conditions that may have an adverse influence on members of the nuclear team. A report is provided to management identifying root cause and contributing factors along with recommended corrective actions

  5. Subjective performance evaluations and employee careers

    DEFF Research Database (Denmark)

    Frederiksen, Anders; Lange, Fabian; Kriechell, Ben

    Firms commonly use supervisor evaluations to assess the performance of employees who work in complex environments. Doubts persist whether their subjective nature invalidates using these performance measures to learn about careers of individuals and to inform theory in personnel economics. We...... examine personnel data from six large companies and establish how subjective ratings, interpreted as ordinal rankings of employee performances within narrowly defined peer-groups, correlate with objective career outcomes. We find many similarities across firms in how subjective ratings correlate with base...

  6. Analytical Performance Evaluation of Different Switch Solutions

    Directory of Open Access Journals (Sweden)

    Francisco Sans

    2013-01-01

    Full Text Available The virtualization of the network access layer has opened new doors in how we perceive networks. With this virtualization of the network, it is possible to transform a regular PC with several network interface cards into a switch. PC-based switches are becoming an alternative to off-the-shelf switches, since they are cheaper. For this reason, it is important to evaluate the performance of PC-based switches. In this paper, we present a performance evaluation of two PC-based switches, using Open vSwitch and LiSA, and compare their performance with an off-the-shelf Cisco switch. The RTT, throughput, and fairness for UDP are measured for both Ethernet and Fast Ethernet technologies. From this research, we can conclude that the Cisco switch presents the best performance, and both PC-based switches have similar performance. Between Open vSwitch and LiSA, Open vSwitch represents a better choice since it has more features and is currently actively developed.

  7. Sustainability performance evaluation: Literature review and future directions.

    Science.gov (United States)

    Büyüközkan, Gülçin; Karabulut, Yağmur

    2018-07-01

    Current global economic activities are increasingly being perceived as unsustainable. Despite the high number of publications, sustainability science remains highly dispersed over diverse approaches and topics. This article aims to provide a structured overview of sustainability performance evaluation related publications and to document the current state of literature, categorize publications, analyze and link trends, as well as highlight gaps and provide research recommendations. 128 articles between 2007 and 2018 are identified. The results suggest that sustainability performance evaluation models shall be more balanced, suitable criteria and their interrelations shall be well defined and subjectivity of qualitative criteria inherent to sustainability indicators shall be considered. To address this subjectivity, group decision-making techniques and other analytical methods that can deal with uncertainty, conflicting indicators, and linguistic evaluations can be used in future works. By presenting research gaps, this review stimulates researchers to establish practically applicable sustainability performance evaluation frameworks to help assess and compare the degree of sustainability, leading to more sustainable business practices. The review is unique in defining corporate sustainability performance evaluation for the first time, exploring the gap between sustainability accounting and sustainability assessment, and coming up with a structured overview of innovative research recommendations about integrating analytical assessment methods into conceptual sustainability frameworks. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Features principles and purposes of teacher performance evaluation.

    Directory of Open Access Journals (Sweden)

    Esnares José Maussa Díaz

    2015-03-01

    Full Text Available Teacher evaluation represents a nodal aspect for improving of system education. Any evaluation has a previously predefined purpose and is essentially a valorative act, where the principles applied are indicators of the degree of responsibility which is performed and the visión that society gives to the education. This paper analyzes how the purposes are fulfilled, principles and characteristics of the performance evaluation of teachers in connection with the practice of respect for the guiding principles of assessment practice teaching; just like existing rating on indicators of professional and personal development achieved by teachers as a result of the evaluative practices in the context of the pursuit of improving of quality of education. 

  9. Fiscal year 1999 Battelle performance evaluation and fee agreement

    Energy Technology Data Exchange (ETDEWEB)

    DAVIS, T.L.

    1998-10-22

    Fiscal Year 1999 represents the third fill year utilizing a results-oriented, performance-based evaluation for the Contractor's operations and management of the DOE Pacific Northwest National Laboratory (here after referred to as the Laboratory). However, this is the first year that the Contractor's fee is totally performance-based utilizing the same Critical Outcomes. This document describes the critical outcomes, objectives, performance indicators, expected levels of performance, and the basis for the evaluation of the Contractor's performance for the period October 1, 1998 through September 30, 1999, as required by Clauses entitled ''Use of Objective Standards of Performance, Self Assessment and Performance Evaluation'' and ''Performance Measures Review'' of the Contract DE-ACO6-76RL01830. Furthermore, it documents the distribution of the total available performance-based fee and the methodology set for determining the amount of fee earned by the Contractor as stipulated within the causes entitled ''Estimated Cost and Annual Fee,'' ''Total Available Fee'' and ''Allowable Costs and Fee.'' In partnership with the Contractor and other key customers, the Department of Energy (DOE) Headquarters (HQ) and Richland Operations Office (RL) has defined four critical outcomes that serve as the core for the Contractor's performance-based evaluation and fee determination. The Contractor also utilizes these outcomes as a basis for overall management of the Laboratory.

  10. Performance evaluation methods and instrumentation for mine ventilation fans

    Institute of Scientific and Technical Information of China (English)

    LI Man; WANG Xue-rong

    2009-01-01

    Ventilation fans are one of the most important pieces of equipment in coal mines. Their performance plays an important role in the safety of staff and production. Given the actual requirements of coal mine production, we instituted a research project on the measurement methods of key performance parameters such as wind pressure, amount of ventilation and power. At the end a virtual instrument for mine ventilation fans performance evaluation was developed using a USB interface. The practical perform-ance and analytical results of our experiments show that it is feasible, reliable and effective to use the proposed instrumentation for mine ventilation performance evaluation.

  11. Individual performance evaluation of the Brazilian Nuclear Energy Commission (CNEN): a meta-evaluative study

    International Nuclear Information System (INIS)

    Bezerra, Leonardo Ferreira

    2017-01-01

    The present study is a summative meta-evaluation that had as objective to evaluate the quality of the process of evaluation of individual performance of the servers of the National Commission of Nuclear Energy, being guided by the scientific curiosity to know to what extent the evaluation of performance the National Commission for Nuclear Energy meets the quality standards disseminated by the Joint Committee on Standards for Educational Evaluation. The methodology chosen to be used was based on the management approach and had as a guiding principle of the study the elaboration of a framework of criteria considering the aforementioned standards. The criteria established in the criteria framework guided the preparation of the items of the questionnaire sent to the National Commission of Nuclear Energy servers. In addition to the questionnaire, the observation of this author was considered in the context where the phenomenon occurred, which allowed a better reflective analysis of the data collected by the questionnaire. Regarding the results, it can be inferred that the performance evaluation developed at the National Commission of Nuclear Energy can be considered of quality, highlighting the servers' trust for the data, the communication process of the program stages, the credibility of the evaluators, the process of negotiation of goals and adaptability of the instrument over the course of the cycle. However, there are some opportunities for improvement, considering the relevance of evaluation as a tool to improve the performance of the autarchy's servers. Among the points that need to be improved is that there is currently a lack of knowledge about the legal basis and justification of the process of evaluation process by the servers and the lack of clarity regarding the content of the final evaluation report. Among the recommendations of this study, one can consider as the most relevant the need to: disseminate the results of this meta-evaluation to the

  12. Performance Evaluation Methods for Assistive Robotic Technology

    Science.gov (United States)

    Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.

    Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.

  13. Hanford performance evaluation program for Hanford site analytical services

    International Nuclear Information System (INIS)

    Markel, L.P.

    1995-09-01

    The U.S. Department of Energy (DOE) Order 5700.6C, Quality Assurance, and Title 10 of the Code of Federal Regulations, Part 830.120, Quality Assurance Requirements, states that it is the responsibility of DOE contractors to ensure that ''quality is achieved and maintained by those who have been assigned the responsibility for performing the work.'' Hanford Analytical Services Quality Assurance Plan (HASQAP) is designed to meet the needs of the Richland Operations Office (RL) for maintaining a consistent level of quality for the analytical chemistry services provided by contractor and commmercial analytical laboratory operations. Therefore, services supporting Hanford environmental monitoring, environmental restoration, and waste management analytical services shall meet appropriate quality standards. This performance evaluation program will monitor the quality standards of all analytical laboratories supporting the Hanforad Site including on-site and off-site laboratories. The monitoring and evaluation of laboratory performance can be completed by the use of several tools. This program will discuss the tools that will be utilized for laboratory performance evaluations. Revision 0 will primarily focus on presently available programs using readily available performance evaluation materials provided by DOE, EPA or commercial sources. Discussion of project specific PE materials and evaluations will be described in section 9.0 and Appendix A

  14. Market behavior and performance of different strategy evaluation schemes

    OpenAIRE

    Yongjoo Baek; Sang Hoon Lee; Hawoong Jeong

    2010-01-01

    Strategy evaluation schemes are a crucial factor in any agent-based market model, as they determine the agents' strategy preferences and consequently their behavioral pattern. This study investigates how the strategy evaluation schemes adopted by agents affect their performance in conjunction with the market circumstances. We observe the performance of three strategy evaluation schemes, the history-dependent wealth game, the trend-opposing minority game, and the trend-following majority game,...

  15. Small Influence of Performing from Memory on Audience Evaluation

    Directory of Open Access Journals (Sweden)

    Reinhard Kopiez

    2017-09-01

    Full Text Available This study investigates the influence of an actual music stand on the evaluation of a videotaped audio-visual solo instrumental performance. Previous research has provided evidence that the presence of a score or music stand (obstructing the audience's view of the performer might negatively influence the evaluation of the performance. However, due to methodological ambiguities, results in previous studies cannot be regarded as definitive. Thus, we conducted a replication study of Williamon (1999 with better control over confounding variables (e.g., varying levels of technical proficiency in different conditions. A violoncello player performed two pieces for solo instrument: once with a music stand on stage (pretending to play from score and once without. The level of technical proficiency was kept constant in both performance presentations by the use of a pre-recorded, well-rehearsed performance from memory. Audio tracks were synchronized with the performance movements in a playback paradigm. Based on the performance evaluations from a web-based experiment (N = 471 participants, we found a significant but small effect size for the main effect of performance presentation (with vs. without music stand (d = 0.23. We conclude that the audience's appreciation of a particular performance from memory might be based on factors other than the objective performance quality.

  16. Electrode polarization studies in hot corrosion systems. Progress report, 1 July 1978--31 May 1979

    Energy Technology Data Exchange (ETDEWEB)

    Devereux, O.F.

    1979-02-01

    Work is reported on thermodynamic analysis of gasifier models, equilibrium calculations performed on two and thre phase equilibrium involving components of coal gas, sodium salts, and carbon. Electrode polarization studies in molten sodium carbonate and polarization tests were performed on iron, steel, nickel, and on 304 and 316 stainless steel in molten sodium carbonate under a variety of exploratory environments. Gas/metal reactions studies, initial evaluation studies iron in hydrogen-hydrogen sulfide mixtures, pertaining to a new gravimetric facility are presented. Evaluation was made of reaction kinetics from polarization. A visual regression procedure utilizing interactive computer graphics is described for the fitting of multiparameter, nonlinear equations to experimental curves.

  17. NREL Evaluates Performance of Fast-Charge Electric Buses

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-16

    This real-world performance evaluation is designed to enhance understanding of the overall usage and effectiveness of electric buses in transit operation and to provide unbiased technical information to other agencies interested in adding such vehicles to their fleets. Initial results indicate that the electric buses under study offer significant fuel and emissions savings. The final results will help Foothill Transit optimize the energy-saving potential of its transit fleet. NREL's performance evaluations help vehicle manufacturers fine-tune their designs and help fleet managers select fuel-efficient, low-emission vehicles that meet their bottom line and operational goals. help Foothill Transit optimize the energy-saving potential of its transit fleet. NREL's performance evaluations help vehicle manufacturers fine-tune their designs and help fleet managers select fuel-efficient, low-emission vehicles that meet their bottom line and operational goals.

  18. An approach for evaluating expert performance in emergency situations

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Kawano, Ryutaro; Yoshimura, Sandanori

    1995-01-01

    To understand expert behavior and define what constitutes good performance in emergency situations in huge and complex plants, human performance evaluation should be made from viewpoints of not only error, but also various cognitive, psychological, and behavioral characteristics. Quantitative and qualitative measures of human performance are proposed for both individual operators and crews, based on the operator performance analysis experiment, among which cognitive and behavioral aspects are the most important. Operator performance should be further analyzed experimentally from the cognitive and behavioral viewpoints, using an evaluation based on various gross indexes considering operator's tasks which should be done in response to plant situations

  19. Performance Evaluation of Incremental K-means Clustering Algorithm

    OpenAIRE

    Chakraborty, Sanjay; Nagwani, N. K.

    2014-01-01

    The incremental K-means clustering algorithm has already been proposed and analysed in paper [Chakraborty and Nagwani, 2011]. It is a very innovative approach which is applicable in periodically incremental environment and dealing with a bulk of updates. In this paper the performance evaluation is done for this incremental K-means clustering algorithm using air pollution database. This paper also describes the comparison on the performance evaluations between existing K-means clustering and i...

  20. 48 CFR 3036.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Evaluation of contractor performance. 3036.201 Section 3036.201 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY... contractor performance. (a)(2) Performance reports shall be prepared and entered into the Contractor...

  1. Performance Evaluation of Security Protocols

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Curti, Michele

    2005-01-01

    We use a special operational semantics which drives us in inferring quantitative measures on systems describing cryptographis cryptographic protocols. We assign rates to transitions by only looking at these labels. The rates reflect the distributed architecture running applications and the use...... of possibly different cryptosystems. We then map transition systems to Markov chains and evaluate performance of systems, using standard tools....

  2. Usage of performance measurement and evaluation systems : the impact of evaluator characteristics

    OpenAIRE

    Gelderman, Maarten

    1998-01-01

    This paper discusses the relation between characteristics of the evaluating manager and the way performance measurement and evaluation information is used. First a discussion is provided about the dependent variable. It is recognized that categorization into archetypes (e.g., evaluative styles) is unsatisfactory. Instead the information content/emphasis dimensions financial-non- financial, quantitative-qualitative, process-outcome, past-future and external-internal, along with the dimension f...

  3. Stochastic modeling of gob gas venthole production performances in active and completed longwall panels of coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Karacan, C. Oezgen [NIOSH, Office of Mine Safety and Health Research, Pittsburgh, PA (United States); Luxbacher, Kray [Virginia Tech, Dept. of Mining and Minerals Engineering, Blacksburg, VA (United States)

    2010-11-01

    Gob gas ventholes (GGVs) are an integral part of longwall coal mining operations, enhancing safety by controlling methane in underground workings. As in many disciplines in earth sciences, uncertainties due to the heterogeneity of geologic formations exist. These uncertainties, and the wide range of mining and venthole operation parameters, lead to performance variability in GGVs. Random variations in parameters affecting GGV performance and influencing parameters that cannot be quantified sufficiently due to lack of information limit deterministic GGV models and even introduce error in severe cases. Therefore, evaluation of GGV performance data and the uncertainty in input parameters is valuable for understanding the variability in GGV production and for designing them accordingly. This paper describes a practical approach for implementing stochastic determination of GGV production performances and for generalizing the prediction capability of deterministic models. Deterministic site-specific models were derived by using the GGV module in the recently developed MCP (Methane Control and Prediction) software suite. These models were generated using multi-parameter regression techniques and were then improved by inclusion of extra input parameters that eliminated the site dependency and improved the predictions. Statistical distributions of input parameters in these models were quantified and tested with the Kolmogorov-Smirnov goodness-of-fit technique. Next, Monte Carlo simulations were performed using these distributions and generalized results for GGV performances were generated. The results of this work indicate that this approach is a promising method of representing the variability in GGV performances and to improve the limited and site-specific character of the deterministic models. (author)

  4. Evaluation of the dynamic and kinematic performance of the THOR dummy : neck performance

    NARCIS (Netherlands)

    Hoofman, M.; van Ratingen, M.R.; Wismans, J.S.H.M.; Cesari, D.

    1998-01-01

    The objective of this study is to evaluate the frontal head-neck performance of the THOR neck with respect to the human frontal head-neck performance and the Hybrid-III frontal head-neck performance. For this purpose, tests were carried out with an isolated THOR and Hybrid-III head-neck system on a

  5. PERFORMANCE EVALUATION OF PENSION FUNDS WITH FUZZY EXPERT SYSTEM

    Directory of Open Access Journals (Sweden)

    SERDAR KORUKOĞLU

    2013-06-01

    Full Text Available Financial rating and ranking firms often use linguistic instead of numerical values. When input data are mostly qualitative and are based on subjective knowledge of experts, the Fuzzy Set Theory provides a solid mathematical model to represent and handle these data. The aim of this study is developing a fuzzy expert model to evaluate the performance of the pension funds by using their risk and return values. The method is used for evaluating the performance of the randomly selected of twenty seven Turkish pension funds. The obtained results proved that the fuzzy expert system is appropriate and consistent for performance evaluation.

  6. Evaluation of new control rooms by operator performance analysis

    International Nuclear Information System (INIS)

    Mori, M; Tomizawa, T.; Tai, I.; Monta, K.; Yoshimura, S.; Hattori, Y.

    1987-01-01

    An advanced supervisory and control system called PODIA TM (Plant Operation by Displayed Information and Automation) was developed by Toshiba. Since this system utilizes computer driven CRTs as a main device for information transfer to operators, thorough system integration tests were performed at the factory and evaluations were made of operators' assessment from the initial experience of the system. The PODIA system is currently installed at two BWR power plants. Based on the experiences from the development of PODIA, a more advanced man-machine interface, Advanced-PODIA (A-PODIA), is developed. A-PODIA enhances the capabilities of PODIA in automation, diagnosis, operational guidance and information display. A-PODIA has been validated by carrying out systematic experiments with a full-scope simulator developed for the validation. The results of the experiments have been analyzed by the method of operator performance analysis and applied to further improvement of the A-PODIA system. As a feedback from actual operational experience, operator performance data in simulator training is an important source of information to evaluate human factors of a control room. To facilitate analysis of operator performance, a performance evaluation system has been developed by applying AI techniques. The knowledge contained in the performance evaluation system was elicited from operator training experts and represented as rules. The rules were implemented by employing an object-oriented paradigm to facilitate knowledge management. In conclusion, it is stated that the feedback from new control room operation can be obtained at an early stage by validation tests and also continuously by comprehensive evaluation (with the help of automated tools) of operator performance in simulator training. The results of operator performance analysis can be utilized for improvement of system design as well as operator training. (author)

  7. Evaluation of the dynamic and kinematic performance of the THOR dummy: neck performance

    NARCIS (Netherlands)

    Hoofman, M.; Ratingen, M.R. van; Wismans, J.S.H.M.

    1998-01-01

    The objective of this study is to evaluate the frontal head-neck performance of the THOR neck with respect to the human frontal head-neck performance and the Hybrid-III frontal head-neck performance. For this purpose, tests were carried out with an isolated THOR and Hybrid-III-neck system on a HyGe

  8. At-Risk Youth Appearance and Job Performance Evaluation

    Science.gov (United States)

    Freeburg, Beth Winfrey; Workman, Jane E.

    2008-01-01

    The goal of this study was to identify the relationship of at-risk youth workplace appearance to other job performance criteria. Employers (n = 30; each employing from 1 to 17 youths) evaluated 178 at-risk high school youths who completed a paid summer employment experience. Appearance evaluations were significantly correlated with evaluations of…

  9. Prospective safety performance evaluation on construction sites.

    Science.gov (United States)

    Wu, Xianguo; Liu, Qian; Zhang, Limao; Skibniewski, Miroslaw J; Wang, Yanhong

    2015-05-01

    This paper presents a systematic Structural Equation Modeling (SEM) based approach for Prospective Safety Performance Evaluation (PSPE) on construction sites, with causal relationships and interactions between enablers and the goals of PSPE taken into account. According to a sample of 450 valid questionnaire surveys from 30 Chinese construction enterprises, a SEM model with 26 items included for PSPE in the context of Chinese construction industry is established and then verified through the goodness-of-fit test. Three typical types of construction enterprises, namely the state-owned enterprise, private enterprise and Sino-foreign joint venture, are selected as samples to measure the level of safety performance given the enterprise scale, ownership and business strategy are different. Results provide a full understanding of safety performance practice in the construction industry, and indicate that the level of overall safety performance situation on working sites is rated at least a level of III (Fair) or above. This phenomenon can be explained that the construction industry has gradually matured with the norms, and construction enterprises should improve the level of safety performance as not to be eliminated from the government-led construction industry. The differences existing in the safety performance practice regarding different construction enterprise categories are compared and analyzed according to evaluation results. This research provides insights into cause-effect relationships among safety performance factors and goals, which, in turn, can facilitate the improvement of high safety performance in the construction industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  11. Metrics for Performance Evaluation of Patient Exercises during Physical Therapy.

    Science.gov (United States)

    Vakanski, Aleksandar; Ferguson, Jake M; Lee, Stephen

    2017-06-01

    The article proposes a set of metrics for evaluation of patient performance in physical therapy exercises. Taxonomy is employed that classifies the metrics into quantitative and qualitative categories, based on the level of abstraction of the captured motion sequences. Further, the quantitative metrics are classified into model-less and model-based metrics, in reference to whether the evaluation employs the raw measurements of patient performed motions, or whether the evaluation is based on a mathematical model of the motions. The reviewed metrics include root-mean square distance, Kullback Leibler divergence, log-likelihood, heuristic consistency, Fugl-Meyer Assessment, and similar. The metrics are evaluated for a set of five human motions captured with a Kinect sensor. The metrics can potentially be integrated into a system that employs machine learning for modelling and assessment of the consistency of patient performance in home-based therapy setting. Automated performance evaluation can overcome the inherent subjectivity in human performed therapy assessment, and it can increase the adherence to prescribed therapy plans, and reduce healthcare costs.

  12. The impact of resident- and self-evaluations on surgeon's subsequent teaching performance

    NARCIS (Netherlands)

    Boerebach, Benjamin C. M.; Arah, Onyebuchi A.; Heineman, Maas Jan; Busch, Olivier R. C.; Lombarts, Kiki M. J. M. H.

    2014-01-01

    This study evaluates how residents' evaluations and self-evaluations of surgeon's teaching performance evolve after two cycles of evaluation, reporting, and feedback. Furthermore, the influence of over- and underestimating own performance on subsequent teaching performance was investigated. In a

  13. The ambiguities of performance-based governance reforms in Italy: Reviving the fortunes of evaluation and performance measurement.

    Science.gov (United States)

    Marra, Mita

    2018-08-01

    Over the past two decades, Italy's administrative reforms have institutionalized evaluation to improve program effectiveness, staff productivity, and results-driven accountability against waste and corruption. Across ministries, regional governments, universities, schools and environmental protection agencies, seemingly unexpected consequences have emerged out of the implementation of performance measurement and evaluation regimes within public organizations. Formal compliance to legally binding evaluation procedures, judicially-sanctioned managerial accountability and lack of cross-agency coordination coupled with long-standing cultural separations among evaluators are some of the ambiguities associated with a performance-based governance system within Italian public administration. Building upon the 'new governane theory,' and qualitative fieldwork, I explore the political consequences of evaluation and performance measurement for possible improvements. From a normative perspective, greater integration between program evaluation and performance measurement can support organizational learning and democratic accountability both at the central and local level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Evaluating building performance in healthcare facilities: an organizational perspective.

    Science.gov (United States)

    Steinke, Claudia; Webster, Lynn; Fontaine, Marie

    2010-01-01

    Using the environment as a strategic tool is one of the most cost-effective and enduring approaches for improving public health; however, it is one that requires multiple perspectives. The purpose of this article is to highlight an innovative methodology that has been developed for conducting comprehensive performance evaluations in public sector health facilities in Canada. The building performance evaluation methodology described in this paper is a government initiative. The project team developed a comprehensive building evaluation process for all new capital health projects that would respond to the aforementioned need for stakeholders to be more accountable and to better integrate the larger organizational strategy of facilities. The Balanced Scorecard, which is a multiparadigmatic, performance-based business framework, serves as the underlying theoretical framework for this initiative. It was applied in the development of the conceptual model entitled the Building Performance Evaluation Scorecard, which provides the following benefits: (1) It illustrates a process to link facilities more effectively to the overall mission and goals of an organization; (2) It is both a measurement and a management system that has the ability to link regional facilities to measures of success and larger business goals; (3) It provides a standardized methodology that ensures consistency in assessing building performance; and (4) It is more comprehensive than traditional building evaluations. The methodology presented in this paper is both a measurement and management system that integrates the principles of evidence-based design with the practices of pre- and post-occupancy evaluation. It promotes accountability and continues throughout the life cycle of a project. The advantage of applying this framework is that it engages health organizations in clarifying a vision and strategy for their facilities and helps translate those strategies into action and measurable performance

  15. A Process For Performance Evaluation Of Real-Time Systems

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2003-12-01

    Full Text Available Real-time developers and engineers must not only meet the system functional requirements, but also the stringent timing requirements. One of the critical decisions leading to meeting these timing requirements is the selection of an operating system under which the software will be developed and run. Although there is ample documentation on real-time systems performance and evaluation, little can be found that combines such information into an efficient process for use by developers. As the software industry moves towards clearly defined processes, creation of appropriate guidelines describing a process for performance evaluation of real-time system would greatly benefit real-time developers. This technology transition research focuses on developing such a process. PROPERT (PROcess for Performance Evaluation of Real Time systems - the process described in this paper - is based upon established techniques for evaluating real-time systems. It organizes already existing real-time performance criteria and assessment techniques in a manner consistent with a well-formed process, based on the Personal Software Process concepts.

  16. Model of service-oriented catering supply chain performance evaluation

    Directory of Open Access Journals (Sweden)

    Juanqiong Gou

    2013-03-01

    Full Text Available Purpose: The aim of this paper is constructing a performance evaluation model for service-oriented catering supply chain. Design/methodology/approach: With the research on the current situation of catering industry, this paper summarized the characters of the catering supply chain, and then presents the service-oriented catering supply chain model based on the platform of logistics and information. At last, the fuzzy AHP method is used to evaluate the performance of service-oriented catering supply chain. Findings: With the analysis of the characteristics of catering supply chain, we construct the performance evaluation model in order to guarantee the food safety, logistics efficiency, price stability and so on. Practical implications: In order to evolve an efficient and effective service supply chain, it can not only used to own enterprise improvement, but also can be used for selecting different customers, to choose a different model of development. Originality/value: This paper has a new definition of service-oriented catering supply chain. And it offers a model to evaluate the performance of this catering supply chain.

  17. Integrated model for supplier selection and performance evaluation

    Directory of Open Access Journals (Sweden)

    Borges de Araújo, Maria Creuza

    2015-08-01

    Full Text Available This paper puts forward a model for selecting suppliers and evaluating the performance of those already working with a company. A simulation was conducted in a food industry. This sector has high significance in the economy of Brazil. The model enables the phases of selecting and evaluating suppliers to be integrated. This is important so that a company can have partnerships with suppliers who are able to meet their needs. Additionally, a group method is used to enable managers who will be affected by this decision to take part in the selection stage. Finally, the classes resulting from the performance evaluation are shown to support the contractor in choosing the most appropriate relationship with its suppliers.

  18. Subjective performance evaluation and gender discrimination

    NARCIS (Netherlands)

    Maas, V.S.; Torres-Gonzalez, R.

    2011-01-01

    Gender discrimination continues to be a problem in organizations. It is therefore important that organizations use performance evaluation methods that ensure equal opportunities for men and women. This article reports the results of an experiment to investigate whether and, if so, how the gender of

  19. A method to evaluate process performance by integrating time and resources

    Science.gov (United States)

    Wang, Yu; Wei, Qingjie; Jin, Shuang

    2017-06-01

    The purpose of process mining is to improve the existing process of the enterprise, so how to measure the performance of the process is particularly important. However, the current research on the performance evaluation method is still insufficient. The main methods of evaluation are mainly using time or resource. These basic statistics cannot evaluate process performance very well. In this paper, a method of evaluating the performance of the process based on time dimension and resource dimension is proposed. This method can be used to measure the utilization and redundancy of resources in the process. This paper will introduce the design principle and formula of the evaluation algorithm. Then, the design and the implementation of the evaluation method will be introduced. Finally, we will use the evaluating method to analyse the event log from a telephone maintenance process and propose an optimization plan.

  20. Determinants of the use of value-based performance measures for managerial performance evaluation

    NARCIS (Netherlands)

    Dekker, H.C.; Groot, T.L.C.M.; Schoute, M.; Wiersma, E.

    2012-01-01

    As value-based (VB) performance measures include firms' cost of capital, they are considered more congruent than earnings measures. Prior studies, however, find that their use for managerial performance evaluation is less extensive than their presumed benefits would suggest. We examine how the

  1. Performance evaluation of seal coat materials and designs.

    Science.gov (United States)

    2011-01-01

    "This project presents an evaluation of seal coat materials and design method. The primary objectives of this research are 1) to evaluate seal coat performance : from various combinations of aggregates and emulsions in terms of aggregate loss; 2) to ...

  2. Fiscal year 1999 Battelle performance evaluation and fee agreement; TOPICAL

    International Nuclear Information System (INIS)

    DAVIS, T.L.

    1998-01-01

    Fiscal Year 1999 represents the third fill year utilizing a results-oriented, performance-based evaluation for the Contractor's operations and management of the DOE Pacific Northwest National Laboratory (here after referred to as the Laboratory). However, this is the first year that the Contractor's fee is totally performance-based utilizing the same Critical Outcomes. This document describes the critical outcomes, objectives, performance indicators, expected levels of performance, and the basis for the evaluation of the Contractor's performance for the period October 1, 1998 through September 30, 1999, as required by Clauses entitled ''Use of Objective Standards of Performance, Self Assessment and Performance Evaluation'' and ''Performance Measures Review'' of the Contract DE-ACO6-76RL01830. Furthermore, it documents the distribution of the total available performance-based fee and the methodology set for determining the amount of fee earned by the Contractor as stipulated within the causes entitled ''Estimated Cost and Annual Fee,'' ''Total Available Fee'' and ''Allowable Costs and Fee.'' In partnership with the Contractor and other key customers, the Department of Energy (DOE) Headquarters (HQ) and Richland Operations Office (RL) has defined four critical outcomes that serve as the core for the Contractor's performance-based evaluation and fee determination. The Contractor also utilizes these outcomes as a basis for overall management of the Laboratory

  3. EVALUATION OF THE FINANCIAL PERFORMANCE OF PENSION FUNDS IN CROATIA

    OpenAIRE

    Dražen Novaković

    2015-01-01

    The aim of this paper is to evaluate the financial performance of pension funds in Croatia. Although there are other factors which are important in the pension funds overall performance, this paper focuses on investment accomplishments. The purpose of measuring portfolio performance is to determine whether portfolio managers add value compared to passive investment strategies. The traditional approach to pension funds’ performance evaluation underlines standard measures of financial performan...

  4. Performance Evaluation of Air-Based Heat Rejection Systems

    Directory of Open Access Journals (Sweden)

    Hannes Fugmann

    2015-01-01

    Full Text Available On the basis of the Number of Transfer Units (NTU method a functional relation between electric power for fans/pumps and effectiveness in dry coolers and wet cooling towers is developed. Based on this relation, a graphical presentation method of monitoring and simulation data of heat rejection units is introduced. The functional relation allows evaluating the thermodynamic performance of differently sized heat rejection units and comparing performance among them. The method is used to evaluate monitoring data of dry coolers of different solar cooling field projects. The novelty of this approach is that performance rating is not limited by a design point or standardized operating conditions of the heat exchanger, but is realizable under flexible conditions.

  5. Software for evaluation of EPR-dosimetry performance

    International Nuclear Information System (INIS)

    Shishkina, E.A.; Timofeev, Yu.S.; Ivanov, D.V.

    2014-01-01

    Electron paramagnetic resonance (EPR) with tooth enamel is a method extensively used for retrospective external dosimetry. Different research groups apply different equipment, sample preparation procedures and spectrum processing algorithms for EPR dosimetry. A uniform algorithm for description and comparison of performances was designed and implemented in a new computer code. The aim of the paper is to introduce the new software 'EPR-dosimetry performance'. The computer code is a user-friendly tool for providing a full description of method-specific capabilities of EPR tooth dosimetry, from metrological characteristics to practical limitations in applications. The software designed for scientists and engineers has several applications, including support of method calibration by evaluation of calibration parameters, evaluation of critical value and detection limit for registration of radiation-induced signal amplitude, estimation of critical value and detection limit for dose evaluation, estimation of minimal detectable value for anthropogenic dose assessment and description of method uncertainty. (authors)

  6. Proposed evaluation framework for assessing operator performance with multisensor displays

    Science.gov (United States)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  7. Comparative evaluation of maintenance performance using subsurvival functions

    DEFF Research Database (Denmark)

    Paulsen, J.L.; Cooke, R.; Nyman, R.

    1997-01-01

    Subsurvival functions are applied to operational data for the control rod drive systems of Nordic nuclear reactors to evaluate maintenance performance. Competing failure modes are preventive and corrective maintenance. Maintenance indicators are defined and evaluated for 8 plants. (C) 1997 Elsevier...

  8. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  9. Performance evaluation of the insurance companies based on AHP

    Science.gov (United States)

    Lu, Manhong; Zhu, Kunping

    2018-04-01

    With the entry of foreign capital, China's insurance industry is under increasing pressure of competition. The performance of a company is the external manifestation of its comprehensive strength. Therefore, the establishment of a scientific evaluation system is of practical significance for the insurance companies. In this paper, based on the financial and non-financial indicators of the companies, the performance evaluation system is constructed by means of the analytic hierarchy process (AHP). In the system, the weights of the indicators which represent the impact on the performance of the companies will be calculated by the process. The evaluation system is beneficial for the companies to realize their own strengths and weaknesses, so as to take steps to enhance the core competitiveness of the companies.

  10. Evaluating supplier quality performance using fuzzy analytical hierarchy process

    Science.gov (United States)

    Ahmad, Nazihah; Kasim, Maznah Mat; Rajoo, Shanmugam Sundram Kalimuthu

    2014-12-01

    Evaluating supplier quality performance is vital in ensuring continuous supply chain improvement, reducing the operational costs and risks towards meeting customer's expectation. This paper aims to illustrate an application of Fuzzy Analytical Hierarchy Process to prioritize the evaluation criteria in a context of automotive manufacturing in Malaysia. Five main criteria were identified which were quality, cost, delivery, customer serviceand technology support. These criteria had been arranged into hierarchical structure and evaluated by an expert. The relative importance of each criteria was determined by using linguistic variables which were represented as triangular fuzzy numbers. The Center of Gravity defuzzification method was used to convert the fuzzy evaluations into their corresponding crisps values. Such fuzzy evaluation can be used as a systematic tool to overcome the uncertainty evaluation of suppliers' performance which usually associated with human being subjective judgments.

  11. Environmental performance evaluation of Beijing's energy use planning

    International Nuclear Information System (INIS)

    Wang Lei; Xu Linyu; Song Huimin

    2011-01-01

    In line with rapid economic development, urban energy consumption is increasing rapidly, resulting in environmental problems. After considering several methods to evaluate the environmental performance of energy use, including: energy ecological footprint, input-output analysis, emergy-exergy analysis, and multi-criteria decision-making, an environmental performance evaluation model is proposed, which combines the analytical hierarchy process, fuzzy extent analysis, and membership degree analysis. In the model, 18 sub-indicators of environmental performance from energy use planning are classified into four categories: structure of energy use and industry, technology and efficiency of energy use, environmental impacts caused by energy use, and the socio-economic benefits of energy use. Membership degree analysis is applied to each indicator. Three energy use scenarios which are, respectively, environment-friendly, technology-led, and economic policy-led are evaluated. The results show that the technology-led energy use planning is best. The sustainable energy use policies are proposed from three aspects, including optimizing the energy use and industrial structure, encouraging development of energy-saving and air pollution control technologies, and enhancing legislation on energy use management. The policies are helpful to optimize the trade-offs between economic growth and environmental protection in Beijing. - Highlights: → Our paper establishes a system of indicators according to the structure of urban energy use planning. → We have created a comprehensive environmental performance evaluation model in the research. → The model and results can serve as an important basis for decision-making to guide local government.

  12. The transport performance evaluation system building of logistics enterprises

    Directory of Open Access Journals (Sweden)

    Xueli Wang

    2013-09-01

    Full Text Available Purpose: modern logistics has a significant role in today’s society, logistics cost accounts for 35% to 50% of total logistics costs, so it’s great significance to improve the transport performance of logistics enterprises. Design/methodology/approach: the authors select the transportation performance evaluation index of logistics enterprise, with the aid of the fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative analysis, construct the transport performance evaluation system of logistics enterprises. Findings: the choice of transport performance evaluation indicator system for Logistics enterprise is in a state of "high", which indicates the indicator selection is reasonable. Research limitations/implications: the selected indicators with experts’ subjective factors can not accurately quantify. Practical implications: it has important practical significance to promote the development of modern logistics enterprises and save social cost. Originality/value: current research methods mainly include the PDCA cycle model, key performance indicators (KPI and benchmarking method, principal component analysis method, etc. The authors for the first time with the aid of fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative research on transport performance problems.

  13. PERFORMANCE EVALUATION OF TYPE I MARINE SANITATION DEVICES

    Science.gov (United States)

    This performance test was designed to evaluate the effectiveness of two Type I Marine Sanitation Devices (MSDs): the Electro Scan Model EST 12, manufactured by Raritan Engineering Company, Inc., and the Thermopure-2, manufactured by Gross Mechanical Laboratories, Inc. Performance...

  14. Materials balance area Custodian Performance Evaluation Program at PNL

    International Nuclear Information System (INIS)

    Dickman, D.A.

    1991-07-01

    The material balance area (MBA) custodian has primary responsibility for control and accountability of nuclear material within an MBA. In this role, the custodian operates as an extension of the facility material control and accountability (MC ampersand A) organization. To effectively meet administrative requirements and protection needs, the custodian must be fully trained in all aspects of MC ampersand A related to the MBA, and custodian performance must be periodically evaluated. DOE Policy requires that each facility provide for a program which assures that each facility provide for a program which assures that personnel performing MC ampersand A functions are (1) trained and/or qualified to perform their duties and responsibilities and (2) knowledgeable of requirements and procedures related to their functions. The MBA Custodian Performance Evaluation Program at PNL uses a variety of assessment techniques to meet this goal, including internal and independent MBA audits, periodic custodian testing, conduct of limited scope performance tests, daily monitoring of MC ampersand A documentation, and reviewing custodian performance during physical inventories. The data collected from these sources is analyzed and incorporated into an annual custodian performance evaluation document, given to each custodian and line management. Development of this program has resulted in significantly improved custodian performance and a marked decrease in finding and observations identified during MBA audits

  15. Comparative analysis of minimal residual disease detection by multiparameter flow cytometry and enhanced ASO RQ-PCR in multiple myeloma

    International Nuclear Information System (INIS)

    Silvennoinen, R; Lundan, T; Kairisto, V; Pelliniemi, T-T; Putkonen, M; Anttila, P; Huotari, V; Mäntymaa, P; Siitonen, S; Uotila, L; Penttilä, T-L; Juvonen, V; Selander, T; Remes, K

    2014-01-01

    Multiparameter flow cytometry (MFC) and allele-specific oligonucleotide real-time quantitative PCR (ASO RQ-PCR) are the two most sensitive methods to detect minimal residual disease (MRD) in multiple myeloma (MM). We compared these methods in 129 paired post-therapy samples from 22 unselected, consecutive MM patients in complete/near complete remission. Appropriate immunophenotypic and ASO RQ-PCR-MRD targets could be detected and MRD analyses constructed for all patients. The high PCR coverage could be achieved by gradual widening of the primer sets used for clonality detection. In addition, for 13 (55%) of the patients, reverse orientation of the ASO primer and individual design of the TaqMan probe improved the sensitivity and specificity of ASO RQ-PCR analysis. A significant nonlinear correlation prevailed between MFC-MRD and PCR-MRD when both were positive. Discordance between the methods was found in 32 (35%) paired samples, which were negative by MFC-MRD, but positive by ASO RQ-PCR. The findings suggest that with the described technique, ASO RQ-PCR can be constructed for all patients with MM. ASO RQ-PCR is slightly more sensitive in MRD detection than 6−10-color flow cytometry. Owing to technical demands ASO RQ-PCR could be reserved for patients in immunophenotypic remission, especially in efficacy comparisons between different drugs and treatment modalities

  16. Probabilistic performance assessments for evaluations of the Yucca Mountain site

    International Nuclear Information System (INIS)

    Rickertsen, L.D.; Noronha, C.J.

    1992-01-01

    Site suitability evaluations are conducted to determine if a repository system at a particular site will be able to meet the performance objectives for that system. Early evaluations to determine if the Yucca Mountain site is suitable for repository development have been made in the face of large uncertainties in site features and conditions. Because of these large uncertainties, the evaluations of the site have been qualitative in nature, focusing on the presence or absence of particular features or conditions thought to be important to performance, rather than on results of quantitative performance assessments. Such a qualitative approach was used in the recently completed evaluation of the Yucca Mountain site, the Early Site-Suitability Evaluation (ESSE). In spite of the qualitative approach, the ESSE was able to conclude that no disqualifying conditions are likely to be present at the site and that all of the geologic conditions that would qualify the site are likely to be met. At the same time, because of the qualitative nature of the approach used in the ESSE, the precise importance of the identified issues relative to performance could not be determined. Likewise, the importance of the issues relative to one another could not be evaluated, and, other than broad recommendations, specific priorities for future testing could not be set. The authors have conducted quantitative performance assessments for the Yucca Mountain site to address these issues

  17. Performance Monitoring and Evaluation in Botswana’s Public Service: Achievements and Challenges

    Directory of Open Access Journals (Sweden)

    Dorothy Mpabanga

    2016-03-01

    Full Text Available The paper aims to explore the implementation of performance monitoring and evaluation tools used in Botswana’s public service. The paper also identifies achievements and challenges of implementing performance monitoring and evaluation system and suggests ways for improvement. This paper uses secondary data sources. The paper reveals lack of performance monitoring and evaluation skills, poor supervision, poor conditions of service and a poor work ethic as some of the factors contributing to ineffective use of performance monitoring and evaluation tools in the service. Leadership commitment and support, benchmarking reforms, training and education, developed administrative and governance structures as well as well-defined public policy and program formulation and implementation processes are some of the success factors to enhanced performance management and evaluation systems in Botswana. The paper argues for adoption of a developmental-led model in order to enhance existing performance monitoring and evaluation system that would improve implementation of government policies and programs. Botswana has been striving to excel in service delivery through performance monitoring and evaluation oriented reforms.

  18. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  19. INDONESIA PUBLIC BANKS PERFORMANCE EVALUATION USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Sugiarto Sugiarto

    2016-10-01

    Full Text Available Return on Asset (ROA is a variable that has the greatest ability in predicting public banks stock prices in Indonesia. The coefficient of determination of ROA on public banks stock prices in Indonesia reached 54.8%. ROA has a significant positive influence on public bank stock prices in Indonesia. Fuzzy logic process on the performance of the 15 public banks in Indonesia have been carried out using the data of ROA for the period 2010 up to 2013. Bank reference performance according to ROA is based on Bank Indonesia Letter No. 6 / 23DPNP / 2011. The performance of each bank was analyzed by conventional methods and as a comparison used fuzzy logic. The evaluation with fuzzy logic method able to provide added value to the currently enforced performance evaluation method. There is significant difference in conclusion between the determination of fuzzy logic models and conventional method

  20. Statistical evaluation of diagnostic performance topics in ROC analysis

    CERN Document Server

    Zou, Kelly H; Bandos, Andriy I; Ohno-Machado, Lucila; Rockette, Howard E

    2016-01-01

    Statistical evaluation of diagnostic performance in general and Receiver Operating Characteristic (ROC) analysis in particular are important for assessing the performance of medical tests and statistical classifiers, as well as for evaluating predictive models or algorithms. This book presents innovative approaches in ROC analysis, which are relevant to a wide variety of applications, including medical imaging, cancer research, epidemiology, and bioinformatics. Statistical Evaluation of Diagnostic Performance: Topics in ROC Analysis covers areas including monotone-transformation techniques in parametric ROC analysis, ROC methods for combined and pooled biomarkers, Bayesian hierarchical transformation models, sequential designs and inferences in the ROC setting, predictive modeling, multireader ROC analysis, and free-response ROC (FROC) methodology. The book is suitable for graduate-level students and researchers in statistics, biostatistics, epidemiology, public health, biomedical engineering, radiology, medi...

  1. Performance evaluation of corrosion-affected reinforced concrete ...

    Indian Academy of Sciences (India)

    M B Anoop

    Abstract. A methodology for performance evaluation of reinforced concrete bridge girders in corrosive ... concrete (RC) members of infrastructural systems, espe- ... bility will be useful for making engineering decisions for ...... Water-cement ratio.

  2. The Effect of Implied Performer Age and Group Membership on Evaluations of Music Performances

    Science.gov (United States)

    Harrington, Ann M.

    2018-01-01

    This study examined the effects of implied performer age and group membership on listeners' evaluations of music performances. Undergraduate music majors (n = 23), nonmusic majors (n = 17), and members of a New Horizons ensemble (n = 16) were presented with six 30-second excerpts of concert band performances. Excerpts were presented to all…

  3. High performance APCS conceptual design and evaluation scoping study

    International Nuclear Information System (INIS)

    Soelberg, N.; Liekhus, K.; Chambers, A.; Anderson, G.

    1998-02-01

    This Air Pollution Control System (APCS) Conceptual Design and Evaluation study was conducted to evaluate a high-performance (APC) system for minimizing air emissions from mixed waste thermal treatment systems. Seven variations of high-performance APCS designs were conceptualized using several design objectives. One of the system designs was selected for detailed process simulation using ASPEN PLUS to determine material and energy balances and evaluate performance. Installed system capital costs were also estimated. Sensitivity studies were conducted to evaluate the incremental cost and benefit of added carbon adsorber beds for mercury control, specific catalytic reduction for NO x control, and offgas retention tanks for holding the offgas until sample analysis is conducted to verify that the offgas meets emission limits. Results show that the high-performance dry-wet APCS can easily meet all expected emission limits except for possibly mercury. The capability to achieve high levels of mercury control (potentially necessary for thermally treating some DOE mixed streams) could not be validated using current performance data for mercury control technologies. The engineering approach and ASPEN PLUS modeling tool developed and used in this study identified APC equipment and system performance, size, cost, and other issues that are not yet resolved. These issues need to be addressed in feasibility studies and conceptual designs for new facilities or for determining how to modify existing facilities to meet expected emission limits. The ASPEN PLUS process simulation with current and refined input assumptions and calculations can be used to provide system performance information for decision-making, identifying best options, estimating costs, reducing the potential for emission violations, providing information needed for waste flow analysis, incorporating new APCS technologies in existing designs, or performing facility design and permitting activities

  4. Composite multi-parameter ranking of real and virtual compounds for design of MC4R agonists: renaissance of the Free-Wilson methodology.

    Science.gov (United States)

    Nilsson, Ingemar; Polla, Magnus O

    2012-10-01

    Drug design is a multi-parameter task present in the analysis of experimental data for synthesized compounds and in the prediction of new compounds with desired properties. This article describes the implementation of a binned scoring and composite ranking scheme for 11 experimental parameters that were identified as key drivers in the MC4R project. The composite ranking scheme was implemented in an AstraZeneca tool for analysis of project data, thereby providing an immediate re-ranking as new experimental data was added. The automated ranking also highlighted compounds overlooked by the project team. The successful implementation of a composite ranking on experimental data led to the development of an equivalent virtual score, which was based on Free-Wilson models of the parameters from the experimental ranking. The individual Free-Wilson models showed good to high predictive power with a correlation coefficient between 0.45 and 0.97 based on the external test set. The virtual ranking adds value to the selection of compounds for synthesis but error propagation must be controlled. The experimental ranking approach adds significant value, is parameter independent and can be tuned and applied to any drug discovery project.

  5. Multiparameter rodent chronic model for complex evaluation of alcoholism-mediated metabolic violations.

    Science.gov (United States)

    Shayakhmetova, Ganna M; Bondarenko, Larysa B; Kovalenko, Valentina M; Kharchenko, Olga I; Bohun, Larisa I; Omelchenko, Yuliya O

    2015-01-01

    Despite of the wide spectrum of alcoholism experimental models, the majority of them are very specialized on the short list of investigated parameters and could not provide reproduction of complex metabolic changes in the rats. The aim of the present study was to estimate whether rats selected by high alcohol preference, allowed free access to 15% alcohol for 150 days, develop simultaneous multilevel disturbances of cell macromolecules structure, metabolism and oxidative/nitrosative stress. Wistar albino male rats were divided into groups: I - rats selected by preferences to alcohol were used for chronic alcoholism modeling by replacing water with 15% ethanol (150 days), II - control. Contents of amino acids in serum, liver mRNA CYP2E1 and CYP3A2 expression, DNA fragmentation and lipid peroxidation levels, the reduced glutathione content, superoxide dismutase, catalase, iNOS and cNOS activities were evaluated. In serum of ethanol-treated rats contents of aspartic acid, serine, glycine, alanine and valine were decreased whereas contents of histidine, methionine and phenylalanine were increased. Liver CYP2E1, CYP3A2 mRNA expression, DNA fragmentation levels significantly elevated. Level of cNOS in ethanol-treated rat's hepatocytes was within the normal limits, whereas iNOS activity was raised 1.6 times. Liver pro- and anti-oxidant system alterations were shown. Rats' chronic 15% alcohol consumption (150 days) led solely to complex metabolomic changes at different levels, which simultaneously characterized cell macromolecules structure, metabolism, and oxidative/nitrosative stress. Rodent model of chronic alcoholism in the proposed modification could be an adequate and reasonably priced tool for further preclinical development and testing of pharmacotherapeutic agents.

  6. Performance evaluation of communication systems via importance sampling

    NARCIS (Netherlands)

    Remondo Bueno, D.

    2000-01-01

    In the design and development of telecommunication systems, the preparation of experiments can be made more effective by predicting the system performance and its dependence on the different system parameters. This can be done by modeling the system and using performance evaluation methods. This

  7. Evaluation of Earning Performance of Female Owned Leather ...

    African Journals Online (AJOL)

    The tools for data analyses were descriptive statistics, income statement and an econometric model involving Ordinary Least Square regression analyses. The earning performance evaluation indicated that the enterprises have performed creditably considering the value of the gross margin analysis which is high and gross ...

  8. A framework for performance evaluation of model-based optical trackers

    NARCIS (Netherlands)

    Smit, F.A.; Liere, van R.

    2008-01-01

    We describe a software framework to evaluate the performance of model-based optical trackers in virtual environments. The framework can be used to evaluate and compare the performance of different trackers under various conditions, to study the effects of varying intrinsic and extrinsic camera

  9. The multi-parameter borehole system and high resolution seismic studies in the western part of the main Marmara Fault in the frame of MARSITE Project.

    Science.gov (United States)

    Ozel, Oguz; Guralp, Cansun; Tunc, Suleyman; Yalcinkaya, Esref

    2016-04-01

    The main objective of this study is to install a multi-parameter borehole system and surface array as close to the main Marmara Fault (MMF) in the western Marmara Sea as possible, and measure continuously the evolution of the state of the fault zone surrounding the MMF and to detect any anomaly or change, which may occur before earthquakes by making use of the data from the arrays already running in the eastern part of the Marmara Sea. The multi-parameter borehole system is composed of very wide dynamic range and stable borehole (VBB) broad band seismic sensor, and incorporate strain meter, tilt meter, and temperature and local hydrostatic pressure measuring devices. The borehole seismic station uses the latest update technologies and design ideas to record "Earth tides" signals to the smallest magnitude -3 events. Additionally, a surface microearthquake observation array, consisting of 8-10 seismometers around the borehole is established to obtain continuous high resolution locations of micro-seismicity and to better understand the existing seismically active structures and their roles in local tectonic settings.Bringing face to face the seismograms of microearthquakes recorded by borehole and surface instruments portrays quite different contents. The shorter recording duration and nearly flat frequency spectrum up to the Nyquist frequencies of borehole records are faced with longer recording duration and rapid decay of spectral amplitudes at higher frequencies of a surface seismogram. The main causative of the observed differences are near surface geology effects that mask most of the source related information the seismograms include, and that give rise to scattering, generating longer duration seismograms. In view of these circumstances, studies on microearthquakes employing surface seismograms may bring on misleading results. Particularly, the works on earthquake physics and nucleation process of earthquakes requires elaborate analysis of tiny events. It is

  10. A new method to evaluate human-robot system performance

    Science.gov (United States)

    Rodriguez, G.; Weisbin, C. R.

    2003-01-01

    One of the key issues in space exploration is that of deciding what space tasks are best done with humans, with robots, or a suitable combination of each. In general, human and robot skills are complementary. Humans provide as yet unmatched capabilities to perceive, think, and act when faced with anomalies and unforeseen events, but there can be huge potential risks to human safety in getting these benefits. Robots provide complementary skills in being able to work in extremely risky environments, but their ability to perceive, think, and act by themselves is currently not error-free, although these capabilities are continually improving with the emergence of new technologies. Substantial past experience validates these generally qualitative notions. However, there is a need for more rigorously systematic evaluation of human and robot roles, in order to optimize the design and performance of human-robot system architectures using well-defined performance evaluation metrics. This article summarizes a new analytical method to conduct such quantitative evaluations. While the article focuses on evaluating human-robot systems, the method is generally applicable to a much broader class of systems whose performance needs to be evaluated.

  11. A key performance measures for evaluating cold supply chain performance in farm industry

    Directory of Open Access Journals (Sweden)

    Shashi Shashi

    2015-08-01

    Full Text Available The main objective of this study was to develop a set of measures, evaluate their importance and effect in cold supply chain performance. This investigation reviewed previous research works on all the stages of the farm product supply chain. Based on farm product supply chain, 4 measures with 31 metrics were identified and developed to measure the cold supply chain performance. A survey was organized to establish the importance and the effect of identified measures. The 5 point Likert scale questionnaire was distributed among SC academics and practitioners. The observed finding infers that the measurement instrument was substantiating for evaluating cold supply chain performance in farm industry. The new developed metrics will help firms improve the visibility of supply among partners and in better decision making. The investigation was enfolded up through the plan of direction intended for future study.

  12. Using Weibull Distribution Analysis to Evaluate ALARA Performance

    International Nuclear Information System (INIS)

    Frome, E.L.; Watkins, J.P.; Hagemeyer, D.A.

    2009-01-01

    As Low as Reasonably Achievable (ALARA) is the underlying principle for protecting nuclear workers from potential health outcomes related to occupational radiation exposure. Radiation protection performance is currently evaluated by measures such as collective dose and average measurable dose, which do not indicate ALARA performance. The purpose of this work is to show how statistical modeling of individual doses using the Weibull distribution can provide objective supplemental performance indicators for comparing ALARA implementation among sites and for insights into ALARA practices within a site. Maximum likelihood methods were employed to estimate the Weibull shape and scale parameters used for performance indicators. The shape parameter reflects the effectiveness of maximizing the number of workers receiving lower doses and is represented as the slope of the fitted line on a Weibull probability plot. Additional performance indicators derived from the model parameters include the 99th percentile and the exceedance fraction. When grouping sites by collective total effective dose equivalent (TEDE) and ranking by 99th percentile with confidence intervals, differences in performance among sites can be readily identified. Applying this methodology will enable more efficient and complete evaluation of the effectiveness of ALARA implementation.

  13. Evaluation model based on FAHP for nuclear power project contract performance

    International Nuclear Information System (INIS)

    Liu Bohang; Cheng Jing

    2012-01-01

    Fuzzy Comprehensive Evaluation is a common tool to analyze comprehensive integration. Fuzzy Analytic Hierarchy Process is an improvement for Analytic Hierarchy Process. Firstly the paper pointed out the concept of FAHP, and then used FAHP to setup an evaluation system model for nuclear power project contract performance. Based on this model, all the evaluation factors were assigned to different weightiness. By weighting the score of each factor, output would be the result which could evaluate the contract performance. On the basis of the research, the paper gave the principle of evaluating contract performance of nuclear power suppliers, which can assure the procurement process. (authors)

  14. Formal Implementation of a Performance Evaluation Model for the Face Recognition System

    Directory of Open Access Journals (Sweden)

    Yong-Nyuo Shin

    2008-01-01

    Full Text Available Due to usability features, practical applications, and its lack of intrusiveness, face recognition technology, based on information, derived from individuals' facial features, has been attracting considerable attention recently. Reported recognition rates of commercialized face recognition systems cannot be admitted as official recognition rates, as they are based on assumptions that are beneficial to the specific system and face database. Therefore, performance evaluation methods and tools are necessary to objectively measure the accuracy and performance of any face recognition system. In this paper, we propose and formalize a performance evaluation model for the biometric recognition system, implementing an evaluation tool for face recognition systems based on the proposed model. Furthermore, we performed evaluations objectively by providing guidelines for the design and implementation of a performance evaluation system, formalizing the performance test process.

  15. Evaluating Innovations in Home Care for Performance Accountability.

    Science.gov (United States)

    Collister, Barbara; Gutscher, Abram; Ambrogiano, Jana

    2016-01-01

    Concerns about rising costs and the sustainability of our healthcare system have led to a drive for innovative solutions and accountability for performance. Integrated Home Care, Calgary Zone, Alberta Health Services went beyond traditional accountability measures to use evaluation methodology to measure the progress of complex innovations to its organization structure and service delivery model. This paper focuses on the first two phases of a three-phase evaluation. The results of the first two phases generated learning about innovation adoption and sustainability, and performance accountability at the program-level of a large publicly funded healthcare organization.

  16. Performance Evaluation and Parameter Identification on DROID III

    Science.gov (United States)

    Plumb, Julianna J.

    2011-01-01

    The DROID III project consisted of two main parts. The former, performance evaluation, focused on the performance characteristics of the aircraft such as lift to drag ratio, thrust required for level flight, and rate of climb. The latter, parameter identification, focused on finding the aerodynamic coefficients for the aircraft using a system that creates a mathematical model to match the flight data of doublet maneuvers and the aircraft s response. Both portions of the project called for flight testing and that data is now available on account of this project. The conclusion of the project is that the performance evaluation data is well-within desired standards but could be improved with a thrust model, and that parameter identification is still in need of more data processing but seems to produce reasonable results thus far.

  17. Subjective performance evaluations and reciprocity in principal-agent relations

    DEFF Research Database (Denmark)

    Sebald, Alexander Christopher; Walzl, Markus

    2014-01-01

    . In contrast to existing models of reciprocity, we find that agents tend to sanction whenever the feedback of principals is below their subjective self-evaluations even if agents' pay-offs are independent of it. In turn, principals provide more positive feedback (relative to their actual performance assessment......We conduct a laboratory experiment with agents working on, and principals benefiting from, a real effort task in which the agents' performance can only be evaluated subjectively. Principals give subjective performance feedback to agents, and agents have an opportunity to sanction principals...... of the agent) if this does not affect their pay-off....

  18. Towards Reliable Evaluation of Anomaly-Based Intrusion Detection Performance

    Science.gov (United States)

    Viswanathan, Arun

    2012-01-01

    This report describes the results of research into the effects of environment-induced noise on the evaluation process for anomaly detectors in the cyber security domain. This research was conducted during a 10-week summer internship program from the 19th of August, 2012 to the 23rd of August, 2012 at the Jet Propulsion Laboratory in Pasadena, California. The research performed lies within the larger context of the Los Angeles Department of Water and Power (LADWP) Smart Grid cyber security project, a Department of Energy (DoE) funded effort involving the Jet Propulsion Laboratory, California Institute of Technology and the University of Southern California/ Information Sciences Institute. The results of the present effort constitute an important contribution towards building more rigorous evaluation paradigms for anomaly-based intrusion detectors in complex cyber physical systems such as the Smart Grid. Anomaly detection is a key strategy for cyber intrusion detection and operates by identifying deviations from profiles of nominal behavior and are thus conceptually appealing for detecting "novel" attacks. Evaluating the performance of such a detector requires assessing: (a) how well it captures the model of nominal behavior, and (b) how well it detects attacks (deviations from normality). Current evaluation methods produce results that give insufficient insight into the operation of a detector, inevitably resulting in a significantly poor characterization of a detectors performance. In this work, we first describe a preliminary taxonomy of key evaluation constructs that are necessary for establishing rigor in the evaluation regime of an anomaly detector. We then focus on clarifying the impact of the operational environment on the manifestation of attacks in monitored data. We show how dynamic and evolving environments can introduce high variability into the data stream perturbing detector performance. Prior research has focused on understanding the impact of this

  19. Evaluating Multiple Object Tracking Performance: The CLEAR MOT Metrics

    Directory of Open Access Journals (Sweden)

    Bernardin Keni

    2008-01-01

    Full Text Available Abstract Simultaneous tracking of multiple persons in real-world environments is an active research field and several approaches have been proposed, based on a variety of features and algorithms. Recently, there has been a growing interest in organizing systematic evaluations to compare the various techniques. Unfortunately, the lack of common metrics for measuring the performance of multiple object trackers still makes it hard to compare their results. In this work, we introduce two intuitive and general metrics to allow for objective comparison of tracker characteristics, focusing on their precision in estimating object locations, their accuracy in recognizing object configurations and their ability to consistently label objects over time. These metrics have been extensively used in two large-scale international evaluations, the 2006 and 2007 CLEAR evaluations, to measure and compare the performance of multiple object trackers for a wide variety of tracking tasks. Selected performance results are presented and the advantages and drawbacks of the presented metrics are discussed based on the experience gained during the evaluations.

  20. Model of service-oriented catering supply chain performance evaluation

    OpenAIRE

    Gou, Juanqiong; Shen, Guguan; Chai, Rui

    2013-01-01

    Purpose: The aim of this paper is constructing a performance evaluation model for service-oriented catering supply chain. Design/methodology/approach: With the research on the current situation of catering industry, this paper summarized the characters of the catering supply chain, and then presents the service-oriented catering supply chain model based on the platform of logistics and information. At last, the fuzzy AHP method is used to evaluate the performance of service-oriented catering ...

  1. Reducing the Effects of Gender Stereotypes on Performance Evaluations.

    Science.gov (United States)

    Bauer, Cara C.; Baltes, Boris B.

    2002-01-01

    Examined whether a structured free recall intervention could decrease the influence of traditional gender stereotypes on the performance evaluations of women. College students provided performance ratings for vignettes describing the performance of male and female professors. Without the intervention, raters who had traditional stereotypes…

  2. Integrated, multi-parameter, investigation of eruptive dynamics at Santiaguito lava dome, Guatemala

    Science.gov (United States)

    Lavallée, Yan; De Angelis, Silvio; Rietbrock, Andreas; Lamb, Oliver; Hornby, Adrian; Lamur, Anthony; Kendrick, Jackie E.; von Aulock, Felix W.; Chigna, Gustavo

    2016-04-01

    Understanding the nature of the signals generated at volcanoes is central to hazard mitigation efforts. Systematic identification and understanding of the processes responsible for the signals associated with volcanic activity are only possible when high-resolution data are available over relatively long periods of time. For this reason, in November 2014, the Liverpool Earth Observatory (LEO), UK, in collaboration with colleagues of the Instituto Nacional de Sismologia, Meteorologia e Hidrologia (INSIVUMEH), Guatemala, installed a large multi-parameter geophysical monitoring network at Santiaguito - the most active volcano in Guatemala. The network, which is to date the largest temporary deployment on Santiaguito, includes nine three-component broadband seismometers, three tiltmeters, and five infrasound microphones. Further, during the initial installation campaign we conducted visual and thermal infrared measurements of surface explosive activity and collected numerous rock samples for geochemical, geophysical and rheological characterisation. Activity at Santiaguito began in 1922, with the extrusion of a series of lava domes. In recent years, persistent dome extrusion has yielded spectacularly episodic piston-like motion displayed by characteristic tilt/seismic patterns (Johnson et al, 2014). This cyclicity episodically concludes with gas emissions or gas-and-ash explosions, observed to progress along a complex fault system in the dome. The explosive activity is associated with distinct geophysical signals characterised by the presence of very-long period earthquakes as well as more rapid inflation/deflation cycles; the erupted ash further evidences partial melting and thermal vesiculation resulting from fault processes (Lavallée et al., 2015). One year of data demonstrates the regularity of the periodicity and intensity of the explosions; analysis of infrasound data suggests that each explosion expulses on the order of 10,000-100,000 kg of gas and ash. We

  3. Performance Evaluation Of Mobile Cellular Networks In Nigeria

    OpenAIRE

    Shoewu, O.O

    2018-01-01

    The aim of this paper is to evaluate the performance of mobile networks such as MTN, GLO, and ETISALAT in Nigeria and suggest ways the performance of digital cellular networks can improve to minimize some of its present short comings or limitations. This paper discusses the performance improvement of digital cellular networks. A non- CDMA cellular network is use in an overall wireless environment for the purpose of this paper. This paper also discusses the performance assessment of three mobi...

  4. Measurement-Based Performance Evaluation of Advanced MIMO Transceiver Designs

    Directory of Open Access Journals (Sweden)

    Schneider Christian

    2005-01-01

    Full Text Available This paper describes the methodology and the results of performance investigations on a multiple-input multiple-output (MIMO transceiver scheme for frequency-selective radio channels. The method relies on offline simulations and employs real-time MIMO channel sounder measurement data to ensure a realistic channel modeling. Thus it can be classified in between the performance evaluation using some predefined channel models and the evaluation of a prototype hardware in field experiments. New aspects for the simulation setup are discussed, which are frequently ignored when using simpler model-based evaluations. Example simulations are provided for an iterative ("turbo" MIMO equalizer concept. The dependency of the achievable bit error rate performance on the propagation characteristics and on the variation in some system design parameters is shown, whereas the antenna constellation is of particular concern for MIMO systems. Although in many of the considered constellations turbo MIMO equalization appears feasible in real field scenarios, there exist cases with poor performance as well, indicating that in practical applications link adaptation of the transmitter and receiver processing to the environment is necessary.

  5. A Proposed RTN Officer Performance Evaluation System

    Science.gov (United States)

    1989-12-01

    Taa& No. WokI Unlit Acca ~def 11¶. TITLE (biclde Securiy ClassifiCation) A PROPOSED ROYAL THAI NAVY OFIICER PERFORM NCE EVALUATION SYSTEM 12. PERSONAL...all aspects of performance into account , the commanding officer uses his opinion to decide who is "the best." There are no standard guidelines for...ftequently used in orgunsadozn as a bais for adminiardstive decisions such as employee promotion., tuufer, and allocation of financial reward; employee

  6. Expected Evaluation, Goals, and Performance: Mood as Input.

    Science.gov (United States)

    Sanna, Lawrence J.; And Others

    1996-01-01

    Research indicates effortful performances are reduced when participants cannot be evaluated. Hypothesized mood interacts with goals to attenuate such reduction in performance. As predicted, when participants' tried to do as much as they could, those in negative moods put forth more effort and persisted longer than those in positive moods,…

  7. The human performance evaluation system at Virginia Power

    International Nuclear Information System (INIS)

    Smith, R.G. III.

    1989-01-01

    The safe operation of nuclear power plants requires high standards of performance, extensive training, and responsive management. Despite a utility's best efforts, inappropriate human actions do occur. Although such inappropriate actions will occur, it is believed that such actions can be minimized and managed. The Federal Aviation Administration has a successful program administered by the National Aeronautics and Space Administration. This program is called the Aviation Safety Reporting System (ASRS). Established in 1975, it is anonymous and nonpunitive. A trial program for several utilities was developed by the Institute of Nuclear Power Operations which used a concept similar to the ASRS reporting process. Based on valuable lessons learned by Virginia Power during the pilot program, an effort was made in 1986 to formalize the Human Performance Evaluation System (HPES) to establish an ongoing problem-solving system for evaluating human performance. Currently, 34 domestic utilities and 3 international utilities voluntarily participate in the implementation of the HPES. Each participating utility has selected and trained personnel to evaluate events involving human error and provide corrective action recommendations to prevent recurrence. It is believed that the use of the HPES can lead to improved safety and operation availability

  8. Using hybrid method to evaluate the green performance in uncertainty.

    Science.gov (United States)

    Tseng, Ming-Lang; Lan, Lawrence W; Wang, Ray; Chiu, Anthony; Cheng, Hui-Ping

    2011-04-01

    Green performance measure is vital for enterprises in making continuous improvements to maintain sustainable competitive advantages. Evaluation of green performance, however, is a challenging task due to the dependence complexity of the aspects, criteria, and the linguistic vagueness of some qualitative information and quantitative data together. To deal with this issue, this study proposes a novel approach to evaluate the dependence aspects and criteria of firm's green performance. The rationale of the proposed approach, namely green network balanced scorecard, is using balanced scorecard to combine fuzzy set theory with analytical network process (ANP) and importance-performance analysis (IPA) methods, wherein fuzzy set theory accounts for the linguistic vagueness of qualitative criteria and ANP converts the relations among the dependence aspects and criteria into an intelligible structural modeling used IPA. For the empirical case study, four dependence aspects and 34 green performance criteria for PCB firms in Taiwan were evaluated. The managerial implications are discussed.

  9. Criteria for performance evaluation

    Directory of Open Access Journals (Sweden)

    David J. Weiss

    2009-03-01

    Full Text Available Using a cognitive task (mental calculation and a perceptual-motor task (stylized golf putting, we examined differential proficiency using the CWS index and several other quantitative measures of performance. The CWS index (Weiss and Shanteau, 2003 is a coherence criterion that looks only at internal properties of the data without incorporating an external standard. In Experiment 1, college students (n = 20 carried out 2- and 3-digit addition and multiplication problems under time pressure. In Experiment 2, experienced golfers (n = 12, also college students, putted toward a target from nine different locations. Within each experiment, we analyzed the same responses using different methods. For the arithmetic tasks, accuracy information (mean absolute deviation from the correct answer, MAD using a coherence criterion was available; for golf, accuracy information using a correspondence criterion (mean deviation from the target, also MAD was available. We ranked the performances of the participants according to each measure, then compared the orders using Spearman's rextsubscript{s}. For mental calculation, the CWS order correlated moderately (rextsubscript{s} =.46 with that of MAD. However, a different coherence criterion, degree of model fit, did not correlate with either CWS or accuracy. For putting, the ranking generated by CWS correlated .68 with that generated by MAD. Consensual answers were also available for both experiments, and the rankings they generated correlated highly with those of MAD. The coherence vs. correspondence distinction did not map well onto criteria for performance evaluation.

  10. Performance Evaluation and HaematologicalParameters of West ...

    African Journals Online (AJOL)

    Performance Evaluation and HaematologicalParameters of West African Dwarf Goats Fed Diet Containing Graded Level of Raw and Fermented Malted Sorghum ... influenced white blood cell count (WBC), lymphocytes, monocytes, basophil and mean corpuscular haemoglobin concentration across the dietary treatments.

  11. Methods of Evaluating Performances for Marketing Strategies

    OpenAIRE

    Ioan Cucu

    2005-01-01

    There are specific methods for assessing and improving the effectiveness of a marketing strategy. A marketer should state in the marketing plan what a marketing strategy is supposed to accomplish. These statements should set forth performance standards, which usually are stated in terms of profits, sales, or costs. Actual performance must be measured in similar terms so that comparisons are possible. This paper describes sales analysis and cost analysis, two general ways of evaluating the act...

  12. Integrating Fuzzy AHP and Fuzzy ARAS for evaluating financial performance

    Directory of Open Access Journals (Sweden)

    Abdolhamid Safaei Ghadikolaei

    2014-09-01

    Full Text Available Multi Criteria Decision Making (MCDM is an advanced field of Operation Research; recently MCDM methods are efficient and common tools for performance evaluation in many areas such as finance and economy. The aim of this study is to show one of applications of mathematics in real word. This study with considering value based measures and accounting based measures simultaneously, provided a hybrid approach of MCDM methods in fuzzy environment for financial performance evaluation of automotive and parts manufacturing industry of Tehran stock exchange (TSE.for this purpose Fuzzy analytic hierarchy process (FAHP is applied to determine the relative important of each criterion, then The companies are ranked according their financial performance by using fuzzy additive ratio assessment (Fuzzy ARAS method. The finding of this study showed effective of this approach in evaluating financial performance.

  13. Evaluating Flight Crew Performance by a Bayesian Network Model

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2018-03-01

    Full Text Available Flight crew performance is of great significance in keeping flights safe and sound. When evaluating the crew performance, quantitative detailed behavior information may not be available. The present paper introduces the Bayesian Network to perform flight crew performance evaluation, which permits the utilization of multidisciplinary sources of objective and subjective information, despite sparse behavioral data. In this paper, the causal factors are selected based on the analysis of 484 aviation accidents caused by human factors. Then, a network termed Flight Crew Performance Model is constructed. The Delphi technique helps to gather subjective data as a supplement to objective data from accident reports. The conditional probabilities are elicited by the leaky noisy MAX model. Two ways of inference for the BN—probability prediction and probabilistic diagnosis are used and some interesting conclusions are drawn, which could provide data support to make interventions for human error management in aviation safety.

  14. Chemical oil-spill dispersants: evaluation of three laboratory procedures for estimating performance

    International Nuclear Information System (INIS)

    Clayton, J.R.; Marsden, P.

    1992-09-01

    The report presents data from studies designed to evaluate characteristics of selected bench-scale test methods for estimating performance of chemical agents for dispersing oil from surface slicks into an underlying water column. In order to mitigate the effect of surface slicks with chemical dispersant agents, however, an on-scene coordinator must have information and an understanding of performance characteristics for available dispersant agents. Performance of candidate dispersant agents can be estimated on the basis of laboratory testing procedures that are designed to evaluate performance of different agents. Data presented in the report assist in the evaluation of candidate test methods for estimating performance of candidate dispersant agents. Three test methods were selected for evaluating performance: the currently accepted Revised Standard EPA test, Environmental Canada's Swirling Flask test, and the IFP-Dilution test

  15. Evaluation of teachers' performance of vision screening in primary

    African Journals Online (AJOL)

    Dr. Petronilla

    Evaluation of Teachers' Performance of Vision Screening in Primary. School Children in Port ... teachers can effectively perform vision screening in school children using ..... may be due to variations in methodology and definitions used, as this ...

  16. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Quan Chen

    2018-01-01

    Full Text Available Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  17. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-01

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice. PMID:29301375

  18. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation.

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhai, Yuming; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-03

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees' low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees' job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  19. Strategic performance evaluation in cancer centers.

    Science.gov (United States)

    Delgado, Rigoberto I; Langabeer, James R

    2009-01-01

    Most research in healthcare strategy has focused on formulating or implementing organizational plans and strategies, and little attention has been dedicated to the post-implementation control and evaluation of strategy, which we contend is the most critical aspect of achieving organizational goals. The objective of this study was to identify strategic control approaches used by major cancer centers in the country and to relate these practices to financial performance. Our intent was to expand the theory and practice of healthcare strategy to focused services, such as oncology. We designed a 17-question survey to capture elements of strategy and performance from our study sample, which comprised major cancer hospitals in the United States and shared similar mandates and resource constraints. The results suggest that high-performing cancer centers use more sophisticated analytical approaches, invest greater financial resources in performance analysis, and conduct more frequent performance reviews than do low-performing organizations. Our conclusions point to the need for a more robust approach to strategic assessment. In this article, we offer a number of recommendations for management to achieve strategic plans and goals on the basis of our research. To our knowledge, this study is one of the first to concentrate on the area of strategic control.

  20. Health-educator performance evaluation for quality teaching ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the efficacy of health educator performance evaluation procedures using the Integrated Quality Management System. This quantitative study used questionnaires to collect data from three hundred and thirty eight respondents selected through a convenient sampling procedure.

  1. performance evaluation of feature sets of minutiae quadruplets

    African Journals Online (AJOL)

    databases. This shows that the evaluation of algorithms on just one or two databases is not sufficient to confirm the performance of tech- niques as they may be database-dependent. Much work was done to find a feature-set that would have a good performance across three. FVC databases of the FVC 2000, 2002 and. 2004 ...

  2. Evaluate Data Center Network Performance

    DEFF Research Database (Denmark)

    Pilimon, Artur

    through a data center network, which is usually built with layer 2 switches and layer 3 routers. The topology of the data center network is crucial for latency in the data communication to and from the data center and between servers in the data center. Tests can be conducted to measure latency and other...... Engineering, scientists evaluate data center network topologies with an SDN-based (Software-Defined Networking) control framework measuring network performance – primarily latency. This can be used to plan data center scaling by testing how a new topology will function before changes are made. Data center...... performance parameters for different data center network topologies. It is however important that tests can be repeated and reproduced to have comparable information from the tests. There are, of course, many topologies that can be used for data center networks. At DTU Fotonik, Department of Photonics...

  3. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    Directory of Open Access Journals (Sweden)

    Yudi Kuang

    2015-01-01

    Full Text Available Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an effective thermal conductivity is unsuitable for evaluating thermal insulation performance of paper cups in the case of fluctuating temperature. In this work, we propose a facile approach to precisely analyze the thermal insulation performance of paper cups in a particular range of temperature by using an evaluation model based on the MISO (Multiple-Input Single-Output technical theory, which includes a characterization parameter (temperature factor and a measurement apparatus. A series of experiments was conducted according to this evaluation model, and the results show that this evaluation model enables accurate characterization of the thermal insulation performance of paper cups and provides an efficient theoretical basis for selecting paper materials for paper cups.

  4. Performance evaluation soil samples utilizing encapsulation technology

    Science.gov (United States)

    Dahlgran, James R.

    1999-01-01

    Performance evaluation soil samples and method of their preparation using encapsulation technology to encapsulate analytes which are introduced into a soil matrix for analysis and evaluation by analytical laboratories. Target analytes are mixed in an appropriate solvent at predetermined concentrations. The mixture is emulsified in a solution of polymeric film forming material. The emulsified solution is polymerized to form microcapsules. The microcapsules are recovered, quantitated and introduced into a soil matrix in a predetermined ratio to form soil samples with the desired analyte concentration.

  5. Optimal contracts based on subjective performance evaluations and reciprocity

    DEFF Research Database (Denmark)

    Sebald, Alexander Christopher; Walzl, Markus

    2015-01-01

    As demonstrated in a recent laboratory experiment (see Sebald & Walzl, 2014), individuals tend to sanction others who subjectively evaluate their performance whenever this assessment falls short of the individuals’ self-evaluation. Interestingly, this is the case even if the individuals’ earnings...

  6. Material balance area custodian performance evaluation program at PNL

    International Nuclear Information System (INIS)

    Dickman, D.A.

    1991-01-01

    This paper reports that the material balance area (MBA) custodian has primary responsibility for control and accountability of nuclear material within an MBA. In this role, the custodian operates as an extension of the facility material control and accountability (MC and A) organization. To effectively meet administrative requirements and protection needs, the custodian must be fully trained in all aspects of MC and A related to the MBA, and custodian performance must be periodically evaluated. U.S. Department of Energy (DOE) Policy requires that each facility provide for a program which ensures that personnel performing MC and A functions are trained and/or qualified to perform their duties and responsibilities and knowledgeable of requirements and procedures related to their functions. the MBA Custodian Performance Evaluation Program at Pacific Northwest Laboratory (PNL) uses a variety of assessment techniques to meet this goal, including internal and independent MBA audits, periodic custodian testing, limited scope performance tests, daily monitoring of MC and A documentation, and reviewing custodian performance during physical inventories

  7. Irradiated fuel performance evaluation technology development

    International Nuclear Information System (INIS)

    Koo, Yang Hyun; Bang, J. G.; Kim, D. H.

    2012-01-01

    Alpha version performance code for dual-cooled annular fuel under steady state operation, so called 'DUOS', has been developed applying performance models and proposed methodology. Furthermore, nonlinear finite element module which could be integrated into transient/accident fuel performance code was also developed and evaluated using commercial FE code. The first/second irradiation and PIE test of annular pellet for dual-cooled annular fuel in the world have been completed. In-pile irradiation test DB of annular pellet up to burnup of 10,000 MWd/MTU through the 1st test was established and cracking behavior of annular pellet and swelling rate at low temperature were studied. To do irradiation test of dual-cooled annular fuel under PWR's simulating steady-state conditions, irradiation test rig/rod design/manufacture of mock-up/performance test have been completed through international collaboration program with Halden reactor project. The irradiation test of large grain pellets has been continued from 2002 to 2011 and completed successfully. Burnup of 70,000 MWd/MTU which is the highest burnup among irradiation test pellets in domestic was achieved

  8. Fuel performance evaluation for the CAFE experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Hirota, Leandro T.

    2011-01-01

    Fuel rod cladding material is the second barrier to prevent the release of radioactive inventories in a PWR reactor. In this sense, an important safety aspect is to assess the fuel behavior under operational conditions. This can be made by means of fuel performance codes and confirmed by experimental measurements. In order to evaluate the fuel behavior of fuel rods in steady-state conditions, it was designed an experimental irradiation device, the Nuclear Fuel Irradiation Circuit (CAFE-Mod1). This device will allow controlling the surface rod temperature, to measure the power associated to the rod and the evolution of fission gas release for a typical PWR fuel pin. However, to support the experimental irradiation program, it is extremely important to simulate the experimental conditions using a fuel performance code. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior during the irradiation program. This evaluation was carried out by means of an adapted fuel performance code. Obtained results have shown that besides of the variation observed for parameters, such as, fuel temperature and fission gas release as a function of fuel enrichment level, the fuel rod integrity was preserved in all studied conditions. (author)

  9. Relationship between kinesiophobia and performance in a functional capacity evaluation

    NARCIS (Netherlands)

    Reneman, MF; Jorritsma, W; Dijkstra, SJ; Dijkstra, PU

    2003-01-01

    Fear of movement and (re) injury (kinesiophobia) has been postulated to play an important role in the performance in a Functional Capacity Evaluation (FCE). This study was performed to analyze the relationship between kinesiophobia and performance in an FCE. Kinesiophobia and FCE performance of 54

  10. Evaluation of performance of extension workers in Lesotho | Mokone ...

    African Journals Online (AJOL)

    Evaluation of performance of extension workers in Lesotho. ... role to play in ensuring that extension workers improve their work performance and as ... This cannot be true since most of the factors that affect efficiency were found to be negative.

  11. Evaluating the Performance of Rijndael Encryption

    Directory of Open Access Journals (Sweden)

    Bogdan CIOBANU

    2012-01-01

    Full Text Available In this paper we present a a comparative analysis of the performance of the Rijndael algorithm, developed with the help of two programming languages, namely C and Matlab. The main goal is to get a full, detailed picture about the functioning of this algorithm. In order to evaluate the performances of the Rijndael algorithm for the two different implementations, we took into account establishing the variable factors within each type of implementation so as to avoid the reasons that might lead to running differences (for instance, the comparison of the two implementations will be performed for the situation in which the encryption key length is the same. We chose to use the traditional algorithm for both types of implementation, in which the input is transformed into 4 blocks of 4 bytes, followed by the handling of each byte from each individual column

  12. Seismic design and evaluation criteria based on target performance goals

    International Nuclear Information System (INIS)

    Murray, R.C.; Nelson, T.A.; Kennedy, R.P.; Short, S.A.

    1994-04-01

    The Department of Energy utilizes deterministic seismic design/evaluation criteria developed to achieve probabilistic performance goals. These seismic design and evaluation criteria are intended to apply equally to the design of new facilities and to the evaluation of existing facilities. In addition, the criteria are intended to cover design and evaluation of buildings, equipment, piping, and other structures. Four separate sets of seismic design/evaluation criteria have been presented each with a different performance goal. In all these criteria, earthquake loading is selected from seismic hazard curves on a probabilistic basis but seismic response evaluation methods and acceptable behavior limits are deterministic approaches with which design engineers are familiar. For analytical evaluations, conservatism has been introduced through the use of conservative inelastic demand-capacity ratios combined with ductile detailing requirements, through the use of minimum specified material strengths and conservative code capacity equations, and through the use of a seismic scale factor. For evaluation by testing or by experience data, conservatism has been introduced through the use of an increase scale factor which is applied to the prescribed design/evaluation input motion

  13. Evaluating energy performance in non-domestic buildings : a review

    NARCIS (Netherlands)

    Borgstein, E.H.; Lamberts, R.; Hensen, J.L.M.

    2016-01-01

    Evaluation methods can be used to determine what constitutes good energy performance in a building. With an increasing focus on energy use of buildings worldwide, this evaluation assumes a fundamental importance. This paper provides a comprehensive review of the available methods for analysing,

  14. performance evaluation of sprinkler irrigation system at mambilla

    African Journals Online (AJOL)

    HOD

    ratio (DPR), irrigation productivity (IP), labour requirements and water quality. Standard procedure was ... The exchangeable cations analysis of Kakara irrigation ... Keywords: Tea, irrigation System, Performance Evaluation. 1. INTRODUCTION.

  15. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  16. Performance Evaluation of Hadoop-based Large-scale Network Traffic Analysis Cluster

    Directory of Open Access Journals (Sweden)

    Tao Ran

    2016-01-01

    Full Text Available As Hadoop has gained popularity in big data era, it is widely used in various fields. The self-design and self-developed large-scale network traffic analysis cluster works well based on Hadoop, with off-line applications running on it to analyze the massive network traffic data. On purpose of scientifically and reasonably evaluating the performance of analysis cluster, we propose a performance evaluation system. Firstly, we set the execution times of three benchmark applications as the benchmark of the performance, and pick 40 metrics of customized statistical resource data. Then we identify the relationship between the resource data and the execution times by a statistic modeling analysis approach, which is composed of principal component analysis and multiple linear regression. After training models by historical data, we can predict the execution times by current resource data. Finally, we evaluate the performance of analysis cluster by the validated predicting of execution times. Experimental results show that the predicted execution times by trained models are within acceptable error range, and the evaluation results of performance are accurate and reliable.

  17. Evaluation of the productive performance characteristics of red ...

    African Journals Online (AJOL)

    Evaluation of the productive performance characteristics of red tilapia ( Oreochromis sp.) injected with shark DNA into skeletal muscles and maintained diets containing different levels of probiotic and amino yeast.

  18. LISA - a powerful program package for LIstmode and Spectral data Analysis

    International Nuclear Information System (INIS)

    Oberstedt, A.; Hambsch, F.J.

    1994-01-01

    LISA is a graphical program package which enables both off-line listmode and spectral data evaluation as well as on-line monitoring while multi-parameter experiments are running. It can be executed on every computer with a UNIX operating system and an X-WINDOW environment, running PV-WAVE from Visual Numerics Incorporation. This package is basically written in the language PV-WAVE CL, but integration of procedures written in the C-language and execution of UNIX shell commands lead to an additional increase of performance. (orig.)

  19. Evaluation criteria for enhanced solar–coal hybrid power plant performance

    International Nuclear Information System (INIS)

    Zhao, Yawen; Hong, Hui; Jin, Hongguang

    2014-01-01

    Attention has been directed toward hybridizing solar energy with fossil power plants since the 1990s to improve reliability and efficiency. Appropriate evaluation criteria were important in the design and optimization of solar–fossil hybrid systems. Two new criteria to evaluate the improved thermodynamic performances in a solar hybrid power plant were developed in this study. Correlations determined the main factors influencing the improved thermodynamic performances. The proposed criteria can be used to effectively integrate solar–coal hybridization systems. Typical 100 MW–1000 MW coal-fired power plants hybridized with solar heat at approximately 300 °C, which was used to preheat the feed water before entering the boiler, were evaluated using the criteria. The integration principle of solar–coal hybrid systems was also determined. The proposed evaluation criteria may be simple and reasonable for solar–coal hybrid systems with multi-energy input, thus directing system performance enhancement. - Highlights: • New criteria to evaluate the solar hybrid power plant were developed. • Typical solar–coal hybrid power plants were evaluated using the criteria. • The integration principle of solar–coal hybrid systems was determined. • The benefits of the solar–coal hybrid system are enhanced at lower solar radiation

  20. Knowledge construction about port performance evaluation: An international literature analysis

    Directory of Open Access Journals (Sweden)

    Karine Somensi

    2017-10-01

    Full Text Available Purpose: This study aims at identifying and analyzing the characteristics of international scientific research that address the literature fragment referring to the Port Performance Evaluation to identify the existence of theoretical alignment of Performance Evaluation notion, as an area of knowledge, with practical area stage, the Port Performance Evaluation. Design/Methodology/Approach: The approach the problem, this paper makes use of qualitative research, since it analyzes the Bibliographical Portfolio characteristics related to the Performance Evaluation Port. The strategy adopted was action research where the authors through their analysis and interpretation made the selection of the  Bibliographical Portfolio. Findings: From the analyzed literature fragment it was possible to identify some misalignment between what has been pointed out in the literature regarding the management practices in the port sector. This discrepancy refers to the management practices that are ignored by port managers, which implies the loss of opportunities and may even come to jeopardize the organization's performance. Research limitations/implications: The literature search was restricted to articles written in the English language, published in indexed scientific journals in the selected databases (ii the restriction by the time limit of articles published after the year 2000; (iii the generation of knowledge based on the characteristics selected by the researchers and (iv the analysis of BP articles regarding the  by the judgment and interpretation of this research authors. It is suggested for future work the expanding this research to other databases, other languages, other features, and continuity of this investigation with the development of "systemic analysis' and 'identifying research opportunities' stages through ProKnow-C. Originality/value: Although two similar works have been developed in the same area of research in 2015, the results achieved have

  1. Citation ranking versus peer evaluation of senior faculty research performance

    DEFF Research Database (Denmark)

    Meho, Lokman I.; Sonnenwald, Diane H.

    2000-01-01

    The purpose of this study is to analyze the relationship between citation ranking and peer evaluation in assessing senior faculty research performance. Other studies typically derive their peer evaluation data directly from referees, often in the form of ranking. This study uses two additional...... indicator of research performance of senior faculty members? Citation data, book reviews, and peer ranking were compiled and examined for faculty members specializing in Kurdish studies. Analysis shows that normalized citation ranking and citation content analysis data yield identical ranking results....... Analysis also shows that normalized citation ranking and citation content analysis, book reviews, and peer ranking perform similarly (i.e., are highly correlated) for high-ranked and low-ranked senior scholars. Additional evaluation methods and measures that take into account the context and content...

  2. Blind Source Parameters for Performance Evaluation of Despeckling Filters

    Directory of Open Access Journals (Sweden)

    Nagashettappa Biradar

    2016-01-01

    Full Text Available The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI, and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink embedded with Stein’s unbiased risk estimation (SURE. The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  3. Blind Source Parameters for Performance Evaluation of Despeckling Filters.

    Science.gov (United States)

    Biradar, Nagashettappa; Dewal, M L; Rohit, ManojKumar; Gowre, Sanjaykumar; Gundge, Yogesh

    2016-01-01

    The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI), and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink) embedded with Stein's unbiased risk estimation (SURE). The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  4. Market behavior and performance of different strategy evaluation schemes.

    Science.gov (United States)

    Baek, Yongjoo; Lee, Sang Hoon; Jeong, Hawoong

    2010-08-01

    Strategy evaluation schemes are a crucial factor in any agent-based market model, as they determine the agents' strategy preferences and consequently their behavioral pattern. This study investigates how the strategy evaluation schemes adopted by agents affect their performance in conjunction with the market circumstances. We observe the performance of three strategy evaluation schemes, the history-dependent wealth game, the trend-opposing minority game, and the trend-following majority game, in a stock market where the price is exogenously determined. The price is either directly adopted from the real stock market indices or generated with a Markov chain of order ≤2 . Each scheme's success is quantified by average wealth accumulated by the traders equipped with the scheme. The wealth game, as it learns from the history, shows relatively good performance unless the market is highly unpredictable. The majority game is successful in a trendy market dominated by long periods of sustained price increase or decrease. On the other hand, the minority game is suitable for a market with persistent zigzag price patterns. We also discuss the consequence of implementing finite memory in the scoring processes of strategies. Our findings suggest under which market circumstances each evaluation scheme is appropriate for modeling the behavior of real market traders.

  5. Preliminary results from an integrated, multi-parameter, experiment at the Santiaguito lava dome complex, Guatemala

    Science.gov (United States)

    De Angelis, S.; Rietbrock, A.; Lavallée, Y.; Lamb, O. D.; Lamur, A.; Kendrick, J. E.; Hornby, A. J.; von Aulock, F. W.; Chigna, G.

    2016-12-01

    Understanding the complex processes that drive volcanic unrest is crucial to effective risk mitigation. Characterization of these processes, and the mechanisms of volcanic eruptions, is only possible when high-resolution geophysical and geological observations are available over comparatively long periods of time. In November 2014, the Liverpool Earth Observatory, UK, in collaboration with the Instituto Nacional de Sismologia, Meteorologia e Hidrologia (INSIVUMEH), Guatemala, established a multi-parameter geophysical network at Santiaguito, one of the most active volcanoes in Guatemala. Activity at Santiaguito throughout the past decade, until the summer of 2015, was characterized by nearly continuous lava dome extrusion accompanied by frequent and regular small-to-moderate gas or gas-and-ash explosions. Over the past two years our network collected a wealth of seismic, acoustic and deformation data, complemented by campaign visual and thermal infrared measurements, and rock and ash samples. Here we present preliminary results from the analysis of this unique dataset. Using acoustic and thermal data collected during 2014-2015 we were able to assess volume fractions of ash and gas in the eruptive plumes. The small proportion of ash inferred in the plumes confirms estimates from previous, independent, studies, and suggests that these events did not involve significant magma fragmentation in the conduit. The results also agree with the suggestion that sacrificial fragmentation along fault zones in the conduit region, due to shear-induced thermal vesiculation, may be at the origin of such events. Finally, starting in the summer of 2015, our experiment captured the transition to a new phase of activity characterized by vigorous vulcanian-style explosions producing large, ash-rich, plumes and frequent hazardous pyroclastic flows, as well as the formation a large summit crater. We present evidence of this transition in the geophysical and geological data, and discuss its

  6. Tribo-performance evaluation of ecofriendly brake friction composite materials

    Science.gov (United States)

    Kumar, Naresh; Singh, Tej; Grewal, G. S.

    2018-05-01

    This paper presents the potential of natural fibre in brake friction materials. Natural fibre filled ecofriendly brake friction materials were developed without Kevlar fibre evaluated for tribo-performance on a chase friction testing machine following SAE J 661a standard. Experimental results indicated that natural fibre enhances the fade performance, but depresses the friction and wear performance, whereas Kevlar fibre improves the friction, wear and recovery performance but depresses the fade performance. Also the results revealed that with the increase in natural fibre content, the friction and fade performances enhanced.

  7. Mindfulness, burnout, and effects on performance evaluations in internal medicine residents.

    Science.gov (United States)

    Braun, Sarah E; Auerbach, Stephen M; Rybarczyk, Bruce; Lee, Bennett; Call, Stephanie

    2017-01-01

    Burnout has been documented at high levels in medical residents with negative effects on performance. Some dispositional qualities, like mindfulness, may protect against burnout. The purpose of the present study was to assess burnout prevalence among internal medicine residents at a single institution, examine the relationship between mindfulness and burnout, and provide preliminary findings on the relation between burnout and performance evaluations in internal medicine residents. Residents (n = 38) completed validated measures of burnout at three time points separated by 2 months and a validated measure of dispositional mindfulness at baseline. Program director end-of-year performance evaluations were also obtained on 22 milestones used to evaluate internal medicine resident performance; notably, these milestones have not yet been validated for research purposes; therefore, the investigation here is exploratory. Overall, 71.1% (n = 27) of the residents met criteria for burnout during the study. Lower scores on the "acting with awareness" facet of dispositional mindfulness significantly predicted meeting burnout criteria χ 2 (5) = 11.88, p = 0.04. Lastly, meeting burnout criteria significantly predicted performance on three of the performance milestones, with positive effects on milestones from the "system-based practices" and "professionalism" domains and negative effects on a milestone from the "patient care" domain. Burnout rates were high in this sample of internal medicine residents and rates were consistent with other reports of burnout during medical residency. Dispositional mindfulness was supported as a protective factor against burnout. Importantly, results from the exploratory investigation of the relationship between burnout and resident evaluations suggested that burnout may improve performance on some domains of resident evaluations while compromising performance on other domains. Implications and directions for future research are discussed.

  8. Using Conjoint Analysis to Evaluate and Reward Teaching Performance

    Science.gov (United States)

    Bacon, Donald R.; Zheng, Yilong; Stewart, Kim A.; Johnson, Carol J.; Paul, Pallab

    2016-01-01

    Although widely used, student evaluations of teaching do not address several factors that should be considered in evaluating teaching performance such as new course preparations, teaching larger classes, and inconvenient class times. Consequently, the incentive exists to avoid certain teaching assignments to achieve high SET scores while…

  9. Performance Evaluations: Bridging the Gap between Today's Goals and Tomorrow's Reality.

    Science.gov (United States)

    Conry, Terry; Kemper, Jim

    1993-01-01

    This article argues that a sound performance evaluation system benefits the employee, supervisor, and organization by providing a written record of efforts, by motivating employees, and by maximizing employee growth potential. It proposes that such performance evaluations are compatible with the Total Quality Management approach. Principles of…

  10. A Domain Specific Language for Performance Evaluation of Medical Imaging Systems

    NARCIS (Netherlands)

    van den Berg, Freek; Remke, Anne Katharina Ingrid; Haverkort, Boudewijn R.H.M.; Turau, Volker; Kwiatkowska, Marta; Mangharam, Rahul; Weyer, Christoph

    2014-01-01

    We propose iDSL, a domain specific language and toolbox for performance evaluation of Medical Imaging Systems. iDSL provides transformations to MoDeST models, which are in turn converted into UPPAAL and discrete-event MODES models. This enables automated performance evaluation by means of model

  11. Application of the Performance Validation Tool for the Evaluation of NSSS Control System Performance

    International Nuclear Information System (INIS)

    Sohn, Suk-whun

    2011-01-01

    When a control system is supplied to nuclear power plant (NPP) under construction, static tests and dynamic tests are typically performed for evaluating its performance. The dynamic test is not realistic for validating the performance of the replaced hardware in operating NPPs because of potential risks and economic burden. We have, therefore, developed a performance validation tool which can evaluate the dynamic performances of the control system without undertaking real plant tests. The window-based nuclear plant performance analyzer (Win-NPA) is used as a virtual NPP in the developed tool and provides appropriate control loads to the target control system via hardwired cables in a manner that the interfaces are identical to the field wiring. The outputs from the control system are used as the simulation inputs of the plant model within the Win-NPA. With this closed-loop configuration, major transient events were simulated to check the performance of the implemented control system by comparing it with that of the control system model of the Win-NPA and that of the old hardware. The developed tool and the methodology were successfully applied to the hardware replacement project for Yonggwang (YGN) 3 and 4 feedwater control system (FWCS) in 2008. Several errors in the implemented control system were fixed through the performance validation tests and the operability tests. As a result, the control system of the YGN 3 and 4 has demonstrated an excellent control performance since then. On the basis of YGN 3 and 4 project experiences, we are performing a similar project in Ulchin (UCN) 3 and 4. This methodology can also be applied to other NPPs under construction as a tool for pre-operational dynamic tests. These performance tests before performing power ascension tests (PATs) are conducive to preventing unnecessary plant transients or unwanted reactor trips caused by hidden errors of control systems during PATs. (author)

  12. Model Performance Evaluation and Scenario Analysis (MPESA) Tutorial

    Science.gov (United States)

    The model performance evaluation consists of metrics and model diagnostics. These metrics provides modelers with statistical goodness-of-fit measures that capture magnitude only, sequence only, and combined magnitude and sequence errors.

  13. Balanced scorecard-based performance evaluation of Chinese county hospitals in underdeveloped areas.

    Science.gov (United States)

    Gao, Hongda; Chen, He; Feng, Jun; Qin, Xianjing; Wang, Xuan; Liang, Shenglin; Zhao, Jinmin; Feng, Qiming

    2018-05-01

    Objective Since the Guangxi government implemented public county hospital reform in 2009, there have been no studies of county hospitals in this underdeveloped area of China. This study aimed to establish an evaluation indicator system for Guangxi county hospitals and to generate recommendations for hospital development and policymaking. Methods A performance evaluation indicator system was developed based on balanced scorecard theory. Opinions were elicited from 25 experts from administrative units, universities and hospitals and the Delphi method was used to modify the performance indicators. The indicator system and the Topsis method were used to evaluate the performance of five county hospitals randomly selected from the same batch of 2015 Guangxi reform pilots. Results There were 4 first-level indicators, 9 second-level indicators and 36 third-level indicators in the final performance evaluation indicator system that showed good consistency, validity and reliability. The performance rank of the hospitals was B > E > A > C > D. Conclusions The performance evaluation indicator system established using the balanced scorecard is practical and scientific. Analysis of the results based on this indicator system identified several factors affecting hospital performance, such as resource utilisation efficiency, medical service price, personnel structure and doctor-patient relationships.

  14. A string matching based algorithm for performance evaluation of ...

    Indian Academy of Sciences (India)

    In this paper, we have addressed the problem of automated performance evaluation of Mathematical Expression (ME) recognition. Automated evaluation requires that recognition output and ground truth in some editable format like LaTeX, MathML, etc. have to be matched. But standard forms can have extraneous symbols ...

  15. Development and Performance Evaluation of Indigenously Made ...

    African Journals Online (AJOL)

    A study was conducted to develop, construct and evaluate the performance of cooling chambers made from factory pressed burnt clay (structure-1), locally molded mud blocks (structure-2) and wood wall (structure-3) for extending the shelf life of mangoes and sweet oranges. It was observed that structure-1 significantly ...

  16. Self-evaluation and Assessments of Performance by Self and Others

    Science.gov (United States)

    Shrauger, J. Sidney; Terbovic, Melanie L.

    1976-01-01

    This study explored the relationship between self-esteem, the perception of competence, and actual competence when performance is attributed to oneself or to someone else. High-self-esteem and low-self-esteem subjects performed a concept-formation task and evaluated their performance. Later they either rerated their own performance or rated the…

  17. Performance Evaluation of the RSG-GAS Micronomad MCA

    International Nuclear Information System (INIS)

    Badriyana, B.; Pujijanto, M.S.

    2000-01-01

    The MicroNOMAD-MCA is a gamma spectrometer for radiation exposure measurement using matrix respond method. The equipment used NAI detector to produced pulse spectrum and then covert to quantities of dosimeter by a computer program. Performance evaluation of the MCA-MicroNOMAD has been done to evaluate the reliability and accuracy of the measurement result. The evaluation was done by comparison test with standard survey meter. Measurement of gamma radiation was performed in the experimental Hall, Operation Hall of the RSG-GAS and outside of reactor building with 15 MW reactor power. The gamma radiation exposure measurement result in the Experimental Hall using the MicroNOMAD MCA and Ion Chamber survey meter are 92,4 x 10 exp 6 rad/hour and (62 ∼ 88) x 10 exp 6 rad/hour, respectively. The gamma radiation exposure in the Operation Hall using the MicroNOMAD MCA and Ion Chamber are 165,4 x 10 exp 6 rad/hour and (167 ∼ 194) x 10 exp 6 rad/hour, respectively. By means of this result it can concluded that the reading error of the MicroNOMAD MCA with standard survey meter is small enough. Beside the point the MicroNOMAD MCA has a good performance for gamma radiation measurement in the energy range of 0,2 - 9 MeV

  18. New Algorithm for Evaluating the Green Supply Chain Performance in an Uncertain Environment

    Directory of Open Access Journals (Sweden)

    Pan Liu

    2016-09-01

    Full Text Available An effective green supply chain (GSC can help an enterprise obtain more benefits and reduce costs. Therefore, developing an effective evaluation method for GSC performance evaluation is becoming increasingly important. In this study, the advantages and disadvantages of the current performance evaluations and algorithms for GSC performance evaluations were discussed and evaluated. Based on these findings, an improved five-dimensional balanced scorecard was proposed in which the green performance indicators were revised to facilitate their measurement. A model based on Rough Set theory, the Genetic Algorithm, and the Levenberg Marquardt Back Propagation (LMBP neural network algorithm was proposed. Next, using Matlab, the Rosetta tool, and the practical data of company F, a case study was conducted. The results indicate that the proposed model has a high convergence speed and an accurate prediction ability. The credibility and effectiveness of the proposed model was validated. In comparison with the normal Back Propagation neural network algorithm and the LMBP neural network algorithm, the proposed model has greater credibility and effectiveness. In practice, this method provides a more suitable indicator system and algorithm for enterprises to be able to implement GSC performance evaluations in an uncertain environment. Academically, the proposed method addresses the lack of a theoretical basis for GSC performance evaluation, thus representing a new development in GSC performance evaluation theory.

  19. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  20. Diverging diamond interchange performance evaluation (I-44 and Route 13)

    Science.gov (United States)

    2011-02-01

    Performance evaluation was conducted on the first diverging diamond interchange (DDI) or double : crossover interchange (DCD) constructed in the United States. This evaluation assessed traffic operations, safety and : public perceptions t...

  1. Chinese Middle School Teachers' Preferences Regarding Performance Evaluation Measures

    Science.gov (United States)

    Liu, Shujie; Xu, Xianxuan; Stronge, James H.

    2016-01-01

    Teacher performance evaluation currently is receiving unprecedented attention from policy makers, scholars, and practitioners worldwide. This study is one of the few studies of teacher perceptions regarding teacher performance measures that focus on China. We employed a quantitative dominant mixed research design to investigate Chinese teachers'…

  2. Performance evaluation of Louisiana superpave mixtures : tech summary.

    Science.gov (United States)

    2008-12-01

    The primary objective of this research was to evaluate the fundamental engineering : properties and mixture performance of Superpave hot mix asphalt (HMA) mixtures : in Louisiana through laboratory mechanistic tests, aggregate gradation analysis, and...

  3. Studies on TOP executive performance evaluation system of Chinese listed companies

    Institute of Scientific and Technical Information of China (English)

    WANG De-wu 王德武; JIANG Guo-qing 姜国庆; JIANG Shuo 姜硕; HUANG Allen R

    2004-01-01

    According to the development status of Chinese listed companies, it is important to implement a stock option incentive plan for the top executives (TE) of the companies. It is necessary to establish a set of indices to evaluate a top executive's performance and award performance-based stock options to them scientifically and reasonably.This thesis sets indices from the perspective of the top executive's behaviour and results,which differs from the traditional methods performance evaluation.

  4. Evaluating the effect of a reader worker program on team performance

    International Nuclear Information System (INIS)

    Hahn, H.A.; Alvarez, Y.P.

    1994-01-01

    When safety, security, or other logistical concerns prevent direct objective assessment of team performance, other evaluation techniques become necessary. In this paper, the effect of a Department of Energy-mandated reader worker program on team performance at a particular DOE facility was evaluated using unstructured observations, informal discussions with technicians, and human reliability analysis. The reader worker program is intended to enhance nuclear explosive safety by improving the reliability of team performance. The three methods used for the evaluation combine to provide a strong indication that team performance is in fact enhanced by a properly implemented reader worker procedure. Because direct quantitative data on dependent variables particular to the task of interest is not available, however, there has been some skepticism regarding the results by staff at the facility

  5. The Impact of Evaluation Use on Accounting Programs’ Performance: An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Sheizi Calheira de Freitas

    2016-11-01

    Full Text Available The Brazilian program of higher education evaluation, broadly known as the National Exam of Students’ Performance (ENADE, represents a governmental effort to gather information on undergraduate educational quality. As a product of that evaluation, reports are made available to each program evaluated. Our present research addresses the impact of ENADE evaluation report utilization on multiple higher education accounting programs’ performance in their subsequent evaluation. Based upon theoretical support from literature about evaluation use, a web-based survey was developed and provided across the country to the coordinators of accounting programs. From a response rate of 62% of the study target population and using multiple regressions, we found that there was a positive correlation between usage of the ENADE evaluation report and the performance of undergraduate accounting programs in their subsequent evaluation. Based upon the reviewed literature and, in accordance with these research results, it is possible to infer that the use of evaluation reports derived from the higher education evaluation system promoted by the Brazilian government can influence the decisions of educational institutions and promote improvement.

  6. Integrating Fuzzy AHP and Fuzzy ARAS for evaluating financial performance

    OpenAIRE

    Abdolhamid Safaei Ghadikolaei; Saber Khalili Esbouei

    2014-01-01

    Multi Criteria Decision Making (MCDM) is an advanced field of Operation Research; recently MCDM methods are efficient and common tools for performance evaluation in many areas such as finance and economy. The aim of this study is to show one of applications of mathematics in real word. This study with considering value based measures and accounting based measures simultaneously, provided a hybrid approach of MCDM methods in fuzzy environment for financial performance evaluation of automotive ...

  7. Evaluating Organizational Performance: Rational, Natural, and Open System Models

    Science.gov (United States)

    Martz, Wes

    2013-01-01

    As the definition of organization has evolved, so have the approaches used to evaluate organizational performance. During the past 60 years, organizational theorists and management scholars have developed a comprehensive line of thinking with respect to organizational assessment that serves to inform and be informed by the evaluation discipline.…

  8. Performance in physiology evaluation: possible improvement by active learning strategies.

    Science.gov (United States)

    Montrezor, Luís H

    2016-12-01

    The evaluation process is complex and extremely important in the teaching/learning process. Evaluations are constantly employed in the classroom to assist students in the learning process and to help teachers improve the teaching process. The use of active methodologies encourages students to participate in the learning process, encourages interaction with their peers, and stimulates thinking about physiological mechanisms. This study examined the performance of medical students on physiology over four semesters with and without active engagement methodologies. Four activities were used: a puzzle, a board game, a debate, and a video. The results show that engaging in activities with active methodologies before a physiology cognitive monitoring test significantly improved student performance compared with not performing the activities. We integrate the use of these methodologies with classic lectures, and this integration appears to improve the teaching/learning process in the discipline of physiology and improves the integration of physiology with cardiology and neurology. In addition, students enjoy the activities and perform better on their evaluations when they use them. Copyright © 2016 The American Physiological Society.

  9. Mindfulness, burnout, and effects on performance evaluations in internal medicine residents

    Directory of Open Access Journals (Sweden)

    Braun SE

    2017-08-01

    Full Text Available Sarah E Braun,1 Stephen M Auerbach,1 Bruce Rybarczyk,1 Bennett Lee,2 Stephanie Call2 1Department of Psychology, School of Humanities and Sciences, Virginia Commonwealth University, Richmond, VA, USA; 2Department of Internal Medicine, Division of General Medicine, Virginia Commonwealth University, Richmond, VA, USA Purpose: Burnout has been documented at high levels in medical residents with negative effects on performance. Some dispositional qualities, like mindfulness, may protect against burnout. The purpose of the present study was to assess burnout prevalence among internal medicine residents at a single institution, examine the relationship between mindfulness and burnout, and provide preliminary findings on the relation between burnout and performance evaluations in internal medicine residents.Methods: Residents (n = 38 completed validated measures of burnout at three time points separated by 2 months and a validated measure of dispositional mindfulness at baseline. Program director end-of-year performance evaluations were also obtained on 22 milestones used to evaluate internal medicine resident performance; notably, these milestones have not yet been validated for research purposes; therefore, the investigation here is exploratory.Results: Overall, 71.1% (n = 27 of the residents met criteria for burnout during the study. Lower scores on the “acting with awareness” facet of dispositional mindfulness significantly predicted meeting burnout criteria χ2(5 = 11.88, p = 0.04. Lastly, meeting burnout criteria significantly predicted performance on three of the performance milestones, with positive effects on milestones from the “system-based practices” and “professionalism” domains and negative effects on a milestone from the “patient care” domain.Conclusion: Burnout rates were high in this sample of internal medicine residents and rates were consistent with other reports of burnout during medical residency. Dispositional

  10. Computer performance evaluation of FACOM 230-75 computer system, (2)

    International Nuclear Information System (INIS)

    Fujii, Minoru; Asai, Kiyoshi

    1980-08-01

    In this report are described computer performance evaluations for FACOM230-75 computers in JAERI. The evaluations are performed on following items: (1) Cost/benefit analysis of timesharing terminals, (2) Analysis of the response time of timesharing terminals, (3) Analysis of throughout time for batch job processing, (4) Estimation of current potential demands for computer time, (5) Determination of appropriate number of card readers and line printers. These evaluations are done mainly from the standpoint of cost reduction of computing facilities. The techniques adapted are very practical ones. This report will be useful for those people who are concerned with the management of computing installation. (author)

  11. BUDGETING, BUDGETARY CONTROL AND PERFORMANCE EVALUATION: Evidence from Hospitality Firms in Nigeria

    Directory of Open Access Journals (Sweden)

    Patrick Egbunike

    2017-12-01

    Full Text Available This study was carried out with the view to address two fundamental issues: first, to determine if there is any association between budget, budgetary control and performance evaluation; second, to ascertain if there is any significant variation in the budget, budgetary control and performance evaluation measures of hospitality firms in Nigeria. The study employed descriptive design and primary data (questionnaire was the major source of data collection. Questionnaire was administered to a total of six hundred (600 employees of ten (10 selected hospitality firms in Nigeria. The data obtained were analyzed using both descriptive and inferential statistics. Findings indicated that budget and budgetary control could serve as an avenue through which hospitality firms in Nigeria can be evaluated. In addition, it was revealed that there is a significant variation in the budget, budgetary control and performance evaluation of hospitality firms in Nigeria. On the basis of the findings, it was recommended that hospitality firms in Nigeria should carry out performance evaluation on every aspect of their budget and budgetary activities as a way of ensuring that budgeted outcomes are met. Also, budgetary costs should be a basis of choosing the most-fit performance evaluation technique for hospitality firms since such

  12. Evaluation of Sub Query Performance in SQL Server

    Science.gov (United States)

    Oktavia, Tanty; Sujarwo, Surya

    2014-03-01

    The paper explores several sub query methods used in a query and their impact on the query performance. The study uses experimental approach to evaluate the performance of each sub query methods combined with indexing strategy. The sub query methods consist of in, exists, relational operator and relational operator combined with top operator. The experimental shows that using relational operator combined with indexing strategy in sub query has greater performance compared with using same method without indexing strategy and also other methods. In summary, for application that emphasized on the performance of retrieving data from database, it better to use relational operator combined with indexing strategy. This study is done on Microsoft SQL Server 2012.

  13. Does Teacher Evaluation Mediate the Effect of Cultural Capital on Educational Performance?

    DEFF Research Database (Denmark)

    Lund, Asta Breinholt; Jæger, Mads Meier

    This study analyzes whether teachers' evaluations of children's academic skills mediate the effect of cultural capital on educational performance. We use ECLS-K data with repeated measures on children in 1st, 3rd and 5th grade and apply fixed effects models, that control for unobserved time...... invariant child and family characteristics. The analysis shows that teacher evaluations have positive effect on educational performance, but that cultural capital has no effect on teacher evaluations. Instead cultural capital has a direct positive effect on educational performance....

  14. Performance Evaluation of the ISS Water Processor Multifiltration Beds

    Science.gov (United States)

    Bowman, Elizabeth M.; Carter, Layne; Wilson, Mark; Cole, Harold; Orozco, Nicole; Snowdon, Doug

    2012-01-01

    The ISS Water Processor Assembly (WPA) produces potable water from a waste stream containing humidity condensate and urine distillate. The primary treatment process is achieved in the Multifiltration Bed, which includes adsorbent media and ion exchange resin for the removal of dissolved organic and inorganic contaminants. The first Multifiltration Bed was replaced on ISS in July 2010 after initial indication of inorganic breakthrough. This bed was returned to ground in July 2011 for an engineering investigation. The water resident in the bed was analyzed for various parameters to evaluate adsorbent loading, performance of the ion exchange resin, microbial activity, and generation of leachates from the ion exchange resin. Portions of the adsorbent media and ion exchange resin were sampled and subsequently desorbed to identify the primary contaminants removed at various points in the bed. In addition, an unused Multifiltration Bed was evaluated after two years in storage to assess the generation of leachates during storage. This assessment was performed to evaluate the possibility that these leachates are impacting performance of the Catalytic Reactor located downstream of the Multifiltration Bed. The results of these investigations and implications to the operation of the WPA on ISS are documented in this paper.

  15. Performance Evaluation of Cutting Fluids Developed from Fixed Oils

    Directory of Open Access Journals (Sweden)

    Emmanuel Ogo ONCHE

    2007-01-01

    Full Text Available In this work, different cutting fluid emulsions of about 10% concentration were developed from fixed oils and the performance of each of the developed cutting fluid was evaluated by a direct comparison with as purchased conventional cutting fluid (control sample, using the ability of each sample to effectively perform as coolant and lubricant during machining operation as determinant. In the evaluation process, straight turning operation on lathe machine at various speeds, but equal time intervals of 10 minutes was used with a 2 mm/min feed rate. It was found that cutting fluid developed from groundnut oil (Sample B performed best as coolant at all experimented speeds, with maximum temperature of 60.5° C at the working zone as against 71.39° C observed for the Control (Sample A. The viscosity 10.76 cSt of Sample B was however, higher than those of Samples A (4.79 cSt and C (6.20 cSt. It was recommended that further work be done to synergize Samples B and C and the cooling effectiveness of the hybridized cutting fluid on the tool-chip interphase, as well as its lubricity be evaluated.

  16. Performance evaluation based on data from code reviews

    OpenAIRE

    Andrej, Sekáč

    2016-01-01

    Context. Modern code review tools such as Gerrit have made available great amounts of code review data from different open source projects as well as other commercial projects. Code reviews are used to keep the quality of produced source code under control but the stored data could also be used for evaluation of the software development process. Objectives. This thesis uses machine learning methods for an approximation of review expert’s performance evaluation function. Due to limitations in ...

  17. Evaluation of analytical performance based on partial order methodology.

    Science.gov (United States)

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Performance evaluation of Chrysopogon zizanoides under urban conditions of Kuwait.

    Science.gov (United States)

    Suleiman, Majda Khalil; Bhat, Narayana Ramachandra; Jacob, Sheena; Al-Burais, Meali

    2018-02-01

    Plant physiological and morphological attributes should be critically evaluated for selecting any species for landscaping projects. The selection of a species should be based on the evaluation of its adaptability, noninvasiveness, growth potential, and performance under the prevailing local arid conditions for their aesthetic looks, soil stabilization, and afforestation values. Chrysopogon zizanoides (Vetiver), is suitable for Kuwait because it can withstand fluctuating temperatures ranging from -14 to 55 °C with unique physical and physiological characteristics. Despite the successful growth performance of Vetiver in landscaping projects mostly in several tropical countries, it has not been utilized and evaluated in the Arabian Gulf region. The objective of the current study was to evaluate the performance of selected ten cultivars of Vetiver (ODV-1, 8, 9, 13, 17, 21, 23, Silent Valley, Urlikal, and Pannimedu) in the deficient soil and environmental conditions of Kuwait in urban landscape at minimal maintenance. It is suggested that based on visual greenery effect and overall growth performance cultivars, Pannimedu, Silent Valley, ODV-13, ODV-8 and ODV-9 can be considered for landscaping projects in Kuwait. To obtain the superior crown volume (which considers height and canopy) cultivar Pannimedu is suggested and to get a bushy growth (considering the number of tillers) cultivar ODV-13 and ODV-8 is found to be suitable.

  19. Evaluating the Impact of Communication Network Performance on Supervisory Supermarket Control

    DEFF Research Database (Denmark)

    Madsen, Jacob Theilgaard; Minko, Tomasz; Madsen, Tatiana Kozlova

    2017-01-01

    This paper addresses the evaluation of the impact of non-ideal communication networks on system performance of hierarchical control systems. It develops a stepwise evaluation approach that is applied to the example scenario of a supervisory controller for supermarket temperature control, addressing...... of communication network performance on the supermarket refrigeration control and resulting energy costs using simulation models. The results show that the controller is resilient to downstream information delays, however upstream delays or up- and downstream information loss can cause significant performance...

  20. A Gold Standards Approach to Training Instructors to Evaluate Crew Performance

    Science.gov (United States)

    Baker, David P.; Dismukes, R. Key

    2003-01-01

    The Advanced Qualification Program requires that airlines evaluate crew performance in Line Oriented Simulation. For this evaluation to be meaningful, instructors must observe relevant crew behaviors and evaluate those behaviors consistently and accurately against standards established by the airline. The airline industry has largely settled on an approach in which instructors evaluate crew performance on a series of event sets, using standardized grade sheets on which behaviors specific to event set are listed. Typically, new instructors are given a class in which they learn to use the grade sheets and practice evaluating crew performance observed on videotapes. These classes emphasize reliability, providing detailed instruction and practice in scoring so that all instructors within a given class will give similar scores to similar performance. This approach has value but also has important limitations; (1) ratings within one class of new instructors may differ from those of other classes; (2) ratings may not be driven primarily by the specific behaviors on which the company wanted the crews to be scored; and (3) ratings may not be calibrated to company standards for level of performance skill required. In this paper we provide a method to extend the existing method of training instructors to address these three limitations. We call this method the "gold standards" approach because it uses ratings from the company's most experienced instructors as the basis for training rater accuracy. This approach ties the training to the specific behaviors on which the experienced instructors based their ratings.

  1. Performance indices and evaluation of algorithms in building energy efficient design optimization

    International Nuclear Information System (INIS)

    Si, Binghui; Tian, Zhichao; Jin, Xing; Zhou, Xin; Tang, Peng; Shi, Xing

    2016-01-01

    Building energy efficient design optimization is an emerging technique that is increasingly being used to design buildings with better overall performance and a particular emphasis on energy efficiency. To achieve building energy efficient design optimization, algorithms are vital to generate new designs and thus drive the design optimization process. Therefore, the performance of algorithms is crucial to achieving effective energy efficient design techniques. This study evaluates algorithms used for building energy efficient design optimization. A set of performance indices, namely, stability, robustness, validity, speed, coverage, and locality, is proposed to evaluate the overall performance of algorithms. A benchmark building and a design optimization problem are also developed. Hooke–Jeeves algorithm, Multi-Objective Genetic Algorithm II, and Multi-Objective Particle Swarm Optimization algorithm are evaluated by using the proposed performance indices and benchmark design problem. Results indicate that no algorithm performs best in all six areas. Therefore, when facing an energy efficient design problem, the algorithm must be carefully selected based on the nature of the problem and the performance indices that matter the most. - Highlights: • Six indices of algorithm performance in building energy optimization are developed. • For each index, its concept is defined and the calculation formulas are proposed. • A benchmark building and benchmark energy efficient design problem are proposed. • The performance of three selected algorithms are evaluated.

  2. A corrosion monitoring system for existing reinforced concrete structures.

    Science.gov (United States)

    2015-05-01

    This study evaluated a multi-parameter corrosion monitoring system for existing reinforced concrete structures in chloride-laden service environments. The system was fabricated based on a prototype concrete corrosion measurement system that : had bee...

  3. Are anonymous evaluations a better assessment of faculty teaching performance? A comparative analysis of open and anonymous evaluation processes.

    Science.gov (United States)

    Afonso, Nelia M; Cardozo, Lavoisier J; Mascarenhas, Oswald A J; Aranha, Anil N F; Shah, Chirag

    2005-01-01

    We compared teaching performance of medical school faculty using anonymous evaluations and open evaluations (in which the evaluator was not anonymous) and examined barriers to open evaluation. Residents and medical students evaluated faculty using an open evaluation instrument in which their identity was indicated in the evaluation. Following this, they completed anonymous evaluation on the same faculty members. Aggregate outcomes using the two evaluation systems were compared. Outcomes by group of evaluators (residents and students) were analyzed. Trainees were also asked to rate the barriers to the open evaluation process. A statistically significant difference between the open and anonymous evaluations was noted across all items, with faculty receiving lower scores on the anonymous evaluations. The mean score for all the items on the open evaluations was 4.45 +/- 0.65, compared to mean score of 4.07 +/- 0.80 on the anonymous evaluations. There was also a statistically significant difference between open and anonymous evaluations in five clinical teaching domains that were evaluated individually. Residents perceived that the three most common barriers to optimal evaluation were an apprehension of possible encounters with the same attending physician in the future, destruction of working relationships with the attending, and a feeling of frustration with the evaluation system. The evaluation of faculty teaching performance is complex. Most academic medical centers use the open evaluation format. This study supports the case for the use of the anonymous evaluation method as a more accurate reflection of teaching performance.

  4. Evaluating cryostat performance for naval applications

    Science.gov (United States)

    Knoll, David; Willen, Dag; Fesmire, James; Johnson, Wesley; Smith, Jonathan; Meneghelli, Barry; Demko, Jonathan; George, Daniel; Fowler, Brian; Huber, Patti

    2012-06-01

    The Navy intends to use High Temperature Superconducting Degaussing (HTSDG) coil systems on future Navy platforms. The Navy Metalworking Center (NMC) is leading a team that is addressing cryostat configuration and manufacturing issues associated with fabricating long lengths of flexible, vacuum-jacketed cryostats that meet Navy shipboard performance requirements. The project includes provisions to evaluate the reliability performance, as well as proofing of fabrication techniques. Navy cryostat performance specifications include less than 1 Wm-1 heat loss, 2 MPa working pressure, and a 25-year vacuum life. Cryostat multilayer insulation (MLI) systems developed on the project have been validated using a standardized cryogenic test facility and implemented on 5-meterlong test samples. Performance data from these test samples, which were characterized using both LN2 boiloff and flow-through measurement techniques, will be presented. NMC is working with an Integrated Project Team consisting of Naval Sea Systems Command, Naval Surface Warfare Center-Carderock Division, Southwire Company, nkt cables, Oak Ridge National Laboratory (ORNL), ASRC Aerospace, and NASA Kennedy Space Center (NASA-KSC) to complete these efforts. Approved for public release; distribution is unlimited. This material is submitted with the understanding that right of reproduction for governmental purposes is reserved for the Office of Naval Research, Arlington, Virginia 22203-1995.

  5. [The Brazilian National Health Surveillance Agency performance evaluation at the management contract model].

    Science.gov (United States)

    Moreira, Elka Maltez de Miranda; Costa, Ediná Alves

    2010-11-01

    The Brazilian National Health Surveillance Agency (Anvisa) is supervised by the Ministry of Health by means of a management contract, a performance evaluation tool. This case study was aimed at describing and analyzing Anvisa's performance evaluation model based on the agency's institutional purpose, according to the following analytical categories: the management contract formalization, evaluation tools, evaluators and institutional performance. Semi-structured interviews and document analysis revealed that Anvisa signed only one management contract with the Ministry of Health in 1999, updated by four additive terms. The Collegiate Board of Directors and the Advisory Center for Strategic Management play the role of Anvisa's internal evaluators and an Assessing Committee, comprising the Ministry of Health, constitutes its external evaluator. Three phases were identified in the evaluation model: the structuring of the new management model (1999-2000), legitimation regarding the productive segment (2001-2004) and widespread legitimation (2005). The best performance was presented in 2000 (86.05%) and the worst in 2004 (40.00%). The evaluation model was shown to have contributed little towards the agency's institutional purpose and the effectiveness measurement of the implemented actions.

  6. Between-individual comparisons in performance evaluation: a perspective from prospect theory.

    Science.gov (United States)

    Wong, Kin Fai Ellick; Kwong, Jessica Y Y

    2005-03-01

    This article examines how between-individual comparisons influence performance evaluations in rating tasks. The authors demonstrated a systematic change in the perceived difference across ratees as a result of changing the way performance information is expressed. Study 1 found that perceived performance difference between 2 individuals was greater when their objective performance levels were presented with small numbers (e.g., absence rates of 2% vs. 5%) than when they were presented with large numbers (e.g., attendance rates of 98% vs. 95%). Extending this finding to situations involving trade-offs between multiple performance attributes across ratees, Study 2 showed that the relative preference for 1 ratee over another actually reversed when the presentation format of the performance information changed. The authors draw upon prospect theory to offer a theoretical framework describing the between-individual comparison aspect of performance evaluation.

  7. Uncertainty evaluation methods for waste package performance assessment

    International Nuclear Information System (INIS)

    Wu, Y.T.; Nair, P.K.; Journel, A.G.; Abramson, L.R.

    1991-01-01

    This report identifies and investigates methodologies to deal with uncertainties in assessing high-level nuclear waste package performance. Four uncertainty evaluation methods (probability-distribution approach, bounding approach, expert judgment, and sensitivity analysis) are suggested as the elements of a methodology that, without either diminishing or enhancing the input uncertainties, can evaluate performance uncertainty. Such a methodology can also help identify critical inputs as a guide to reducing uncertainty so as to provide reasonable assurance that the risk objectives are met. This report examines the current qualitative waste containment regulation and shows how, in conjunction with the identified uncertainty evaluation methodology, a framework for a quantitative probability-based rule can be developed that takes account of the uncertainties. Current US Nuclear Regulatory Commission (NRC) regulation requires that the waste packages provide ''substantially complete containment'' (SCC) during the containment period. The term ''SCC'' is ambiguous and subject to interpretation. This report, together with an accompanying report that describes the technical considerations that must be addressed to satisfy high-level waste containment requirements, provides a basis for a third report to develop recommendations for regulatory uncertainty reduction in the ''containment''requirement of 10 CFR Part 60. 25 refs., 3 figs., 2 tabs

  8. Evaluation of manual wheelchair performance in everyday life

    NARCIS (Netherlands)

    van der Woude, L.H.V.; de Groot, S.; van Drongelen, S.; Janssen, T.W.J.; Haisma, J.; Valent, L.; Veeger, H.E.J.

    2009-01-01

    Evaluation of wheelchair performance (capacity and skills) is crucial in the investigation of wheeled mobility in people with a spinal cord injury (SCI). Manual wheelchair use is a complex combination of skills, which together determine overall functioning, daily activities, participation, and

  9. EVALUATION OF THE FINANCIAL PERFORMANCE OF PENSION FUNDS IN CROATIA

    Directory of Open Access Journals (Sweden)

    Dražen Novaković

    2015-07-01

    Full Text Available The aim of this paper is to evaluate the financial performance of pension funds in Croatia. Although there are other factors which are important in the pension funds overall performance, this paper focuses on investment accomplishments. The purpose of measuring portfolio performance is to determine whether portfolio managers add value compared to passive investment strategies. The traditional approach to pension funds’ performance evaluation underlines standard measures of financial performance (e.g. ratios such as Sharpe’s, Sortino’s, Treynor’s, etc. which quantify the ability of pension fund managers to deliver an active management risk premium, with respect to benchmarks. In this paper, the previously mentioned traditional measures of risk-adjusted performance are applied to Croatian pension funds. Due to recent changes in pension systems in other Eastern European countries once again emphasis is put on this issue in Croatia. The analysis furthermore includes evaluation of pension funds’ asset allocation. The period of analysis covers twelve years, from the establishment of pension funds in Croatia in 2002 until 2013. The main hypothesis of the paper states that Croatian pension funds underperform with respect to benchmark comparisons, set as return on the combined CROBEX/CROBIS portfolio. Results show that the main hypothesis does not hold. The financial performance of pension funds directly influences their competitiveness, derived from the possibility of measuring their success in active portfolio management. In addition, pension funds are expected to support the national economy. By investing their accumulating assets, they can protect jobs and enhance economic growth. However, they can achieve that only if they are competitive in means of financial performance.

  10. Computerised self-evaluation of performance in professional English

    Directory of Open Access Journals (Sweden)

    Galina Kavaliauskienė

    2014-10-01

    Full Text Available Purpose – the focus of this article is to explore self-evaluation of performance in professional English that students have to do in university studies. It is clear that students can have various problems in learning English and make mistakes in listening, speaking, reading, writing, and vocabulary. Speaking and listening are the skills that are more common on an everyday basis than reading and writing. Speaking and listening skills have been known to be more difficult to master. English vocabulary presents another problem for language learners. At the university level, students study professional English, also called English for Specific Purposes (ESP. Students will need it for their future profession, so it is important for them to be able to evaluate their achievements in learning.Methodology/approach – the research paper adopts the qualitative research approach. The questionnaire on learner perceptions of computerized self-evaluation of various activities was administered to students of three different specializations. Students‘ perceptions of success or failure in their performance were analyzed.Findings. The results indicated that attitudes to computerized self-evaluation depended on the difficulty of tasks and chosen future specialization. The findings show that respondents of three investigated specializations encounter similar difficulties, but to a different degree. There are no specific problems in performance due to the complexity of the professional vocabulary that students must learn. The computations of Pearson’s correlations coefficients demonstrate that there are good correlational relationships within each specialization. The ratings of Psychology (PS students reveal higher mean values and lower scattering of Standard Deviations in Moodle tasks than the ratings of Internet Management and Communication (IMC students.Research limitations. The investigated samples contain the limited number of respondents, which might

  11. Thermodynamic evaluation of solar-geothermal hybrid power plants in northern Chile

    International Nuclear Information System (INIS)

    Cardemil, José Miguel; Cortés, Felipe; Díaz, Andrés; Escobar, Rodrigo

    2016-01-01

    Highlights: • Thermodynamic evaluation of geothermal-solar hybrid systems. • A multi-parameter analysis for different cycle configurations. • Performance comparison between two operation modes. • Overview of the technical applicability of the hybridization. - Abstract: A thermodynamic model was developed using Engineering Equation Solver (EES) to evaluate the performance of single and double-flash geothermal power plants assisted by a parabolic trough solar concentrating collector field, considering four different geothermal reservoir conditions. The benefits of delivering solar thermal energy for either the superheating or evaporating processes were analyzed in order to achieve the maximum 2"n"d law efficiency for the hybrid schemes and reduce the geothermal resource consumption for a constant power production. The results of the hybrid single-flash demonstrate that the superheating process generates additional 0.23 kWe/kWth, while supplying solar heat to evaporate the geothermal brine only delivers 0.16 kWe/kWth. The double-flash hybrid plant simulation results allow obtaining 0.29 kWe/kWth and 0.17 kW/kWth by integrating solar energy at the superheater and evaporator, respectively. In this context, the hybrid single-flash power plant is able to produce at least 20% additional power output, depending on the characteristics of the geothermal resource. Moreover, all of the cases analyzed herein increased the exergy efficiency of the process by at least 3%. The developed model also allowed assessing the reduction on the consumption of the geothermal fluid from the reservoir when the plant power output stays constant, up to 16% for the hybrid single-flash, and 19% for the hybrid double-flash. Based on the results obtained in this study, the solar-geothermal hybrid scheme increases the power generation compared with geothermal-only power plants, being an attractive solution for improved management of the geothermal reservoir depletion rates. The study shows

  12. Data Envelopment Analysis as a Tool for Evaluation of Employees Performance

    Directory of Open Access Journals (Sweden)

    ZBRANEK

    2013-02-01

    Full Text Available Employee performance evaluation systems, which are well designed and properly used, are essential for the effective functioning of the organization. Due to some disadvantages of traditional methods, there is a need to develop new evaluation procedures. The main contribution of this paper is to apply a multidimensional approach, represented by the method of Data Envelopment Analysis (DEA to measure the performance and efficiency of employees. This approach overcomes several weaknesses of traditional systems of the employees’ performance evaluation and provides a comprehensive indicator of the performance of individual employees, their technical efficiency score. The input variables of the used model were the motivational factors (salary, working conditions and benefits; the output was the indirectly assessed performance through work motivation, job satisfaction and organizational commitment. Furthermore, we applied the nonparametric methods for compliance testing of mean values to validate the stated hypotheses. In a baking company using the DEA method, we identified 12 efficient employees and 48 employees who need to improve their outputs to achieve their maximum efficiency.

  13. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  14. High-level waste-form-product performance evaluation

    International Nuclear Information System (INIS)

    Bernadzikowski, T.A.; Allender, J.S.; Stone, J.A.; Gordon, D.E.; Gould, T.H. Jr.; Westberry, C.F. III.

    1982-01-01

    Seven candidate waste forms were evaluated for immobilization and geologic disposal of high-level radioactive wastes. The waste forms were compared on the basis of leach resistance, mechanical stability, and waste loading. All forms performed well at leaching temperatures of 40, 90, and 150 0 C. Ceramic forms ranked highest, followed by glasses, a metal matrix form, and concrete. 11 tables

  15. The utilization of performance evaluation instruments by technical trainers to evaluate maintenance personnel in the nuclear power industry in the United States

    International Nuclear Information System (INIS)

    Hornberger, C.K.

    1993-01-01

    The purpose of this study was to document the utilization of performance evaluation instruments by technical trainers in the evaluation of maintenance personnel in US nuclear power plants. Performance evaluation of maintenance personnel has been identified by nuclear utilities and the Nuclear Regulatory Commission as the only acceptable method of determining worker competence. The NRC requires performance evaluation to be conducted to performance standards, but it does not specify the standards or the method to be utilized. Each plant is free to establish its own standards and methods of evaluation. This was a descriptive study utilizing descriptive statistics for the analysis of the data. The subjects included 655 maintenance trainers in 72 US nuclear plants. Conclusions of the study include: (1) Technical trainers are in compliance with NRC regulations. (2) Evaluation materials developed by the Institute of Nuclear Power Operations are used by technical trainers in every one of the 62 plants that responded. (3) In-plant or self-developed Performance Evaluation Instruments are utilized by 419 or 95.2% of the technical trainers. (4) Technical trainers incorporate nine common components into their Performance Evaluation Instruments. (5) Technical trainers evaluate maintenance processes and the product produced by workers when following procedures and specifications are critical and when safety hazards are involved. (6) Technical trainers believe that utilizing Performance Evaluation Instruments makes their job easier by providing documentation about the quality and standards of maintenance skills. (7) Technical trainers believe that maintenance workers benefit when their skills are assessed through the use of Performance Evaluation Instruments

  16. Exploration of nuclear power enterprise 'STAR' management performance evaluation system

    International Nuclear Information System (INIS)

    Wang Sen

    2005-01-01

    From the angle of nuclear power enterprise safety culture, this essay breaks the connotations of the safety culture down to nine aspects (target management, safety management, quality management, housekeeping, cost control, authorization management, teamwork, communication and continued improvement), with each aspect divided into five levels of star class according to its own characteristics. A comparison is made between the actualities of the enterprise and star management performance evaluation system to find out the gap and identify ways of continued improvement to elevate the enterprise management level, thereby developing a standard system of conducting qualitative and quantitative evaluation to the management process. Apart from its evaluation function, this system provides a guideline on the work orientation, method, and steps to elevate work level and capability for the managers performing specific management actions. It is also a system of measuring and evaluating the executive force of the company's management and its employees. (author)

  17. Ergonomic evaluation model of operational room based on team performance

    Directory of Open Access Journals (Sweden)

    YANG Zhiyi

    2017-05-01

    Full Text Available A theoretical calculation model based on the ergonomic evaluation of team performance was proposed in order to carry out the ergonomic evaluation of the layout design schemes of the action station in a multitasking operational room. This model was constructed in order to calculate and compare the theoretical value of team performance in multiple layout schemes by considering such substantial influential factors as frequency of communication, distance, angle, importance, human cognitive characteristics and so on. An experiment was finally conducted to verify the proposed model under the criteria of completion time and accuracy rating. As illustrated by the experiment results,the proposed approach is conductive to the prediction and ergonomic evaluation of the layout design schemes of the action station during early design stages,and provides a new theoretical method for the ergonomic evaluation,selection and optimization design of layout design schemes.

  18. NREL Evaluates Performance of Hydraulic Hybrid Refuse Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    This highlight describes NREL's evaluation of the in-service performance of 10 next-generation hydraulic hybrid refuse vehicles (HHVs), 8 previous-generation (model year 2013) HHVs, and 8 comparable conventional diesel vehicles operated by Miami-Dade County's Public Works and Waste Management Department in southern Florida. Launched in March 2015, the on-road portion of this 12-month evaluation focuses on collecting and analyzing vehicle performance data - fuel economy, maintenance costs, and drive cycles - from the HHVs and the conventional diesel vehicles. The fuel economy of heavy-duty vehicles, such as refuse trucks, is largely dependent on the load carried and the drive cycles on which they operate. In the right applications, HHVs offer a potential fuel-cost advantage over their conventional counterparts. This advantage is contingent, however, on driving behavior and drive cycles with high kinetic intensity that take advantage of regenerative braking. NREL's evaluation will assess the performance of this technology in commercial operation and help Miami-Dade County determine the ideal routes for maximizing the fuel-saving potential of its HHVs. Based on the field data, NREL will develop a validated vehicle model using the Future Automotive Systems Technology Simulator, also known as FASTSim, to study the impacts of route selection and other vehicle parameters. NREL is also analyzing fueling and maintenance data to support total-cost-of-ownership estimations and forecasts. The study aims to improve understanding of the overall usage and effectiveness of HHVs in refuse operation compared to similar conventional vehicles and to provide unbiased technical information to interested stakeholders.

  19. Development and Psychometric Evaluation of the Nursing Instructors? Clinical Teaching Performance Inventory

    OpenAIRE

    Farahani, Mansoureh A.; Ghasemi, Hormat Sadat Emamzadeh; Nikpeyma, Nasrin; Fereidouni, Zhila; Rassouli, Maryam

    2014-01-01

    Evaluation of nursing instructors? clinical teaching performance is a prerequisite to the quality assurance of nursing education. One of the most common procedures for this purpose is using student evaluations. This study was to develop and evaluate the psychometric properties of Nursing Instructors? Clinical Teaching Performance Inventory (NICTPI). The primary items of the inventory were generated by reviewing the published literature and the existing questionnaires as well as consulting wit...

  20. A performance evaluation of in-memory databases

    Directory of Open Access Journals (Sweden)

    Abdullah Talha Kabakus

    2017-10-01

    Full Text Available The popularity of NoSQL databases has increased due to the need of (1 processing vast amount of data faster than the relational database management systems by taking the advantage of highly scalable architecture, (2 flexible (schema-free data structure, and, (3 low latency and high performance. Despite that memory usage is not major criteria to evaluate performance of algorithms, since these databases serve the data from memory, their memory usages are also experimented alongside the time taken to complete each operation in the paper to reveal which one uses the memory most efficiently. Currently there exists over 225 NoSQL databases that provide different features and characteristics. So it is necessary to reveal which one provides better performance for different data operations. In this paper, we experiment the widely used in-memory databases to measure their performance in terms of (1 the time taken to complete operations, and (2 how efficiently they use memory during operations. As per the results reported in this paper, there is no database that provides the best performance for all data operations. It is also proved that even though a RDMS stores its data in memory, its overall performance is worse than NoSQL databases.

  1. Performance evaluation software moving object detection and tracking in videos

    CERN Document Server

    Karasulu, Bahadir

    2013-01-01

    Performance Evaluation Software: Moving Object Detection and Tracking in Videos introduces a software approach for the real-time evaluation and performance comparison of the methods specializing in moving object detection and/or tracking (D&T) in video processing. Digital video content analysis is an important item for multimedia content-based indexing (MCBI), content-based video retrieval (CBVR) and visual surveillance systems. There are some frequently-used generic algorithms for video object D&T in the literature, such as Background Subtraction (BS), Continuously Adaptive Mean-shift (CMS),

  2. performance evaluation of a pilot paraplegic centricity mobility aid

    African Journals Online (AJOL)

    eobe

    PERFORMANCE EVALUATION OF A PILOT PARAPLEGIC CENTRICITY. MOBILITY AID. MOBILITY ... The result of the test showed a remarkable improvement in. Wilcoxin's signed rank test. .... RESEARCH METHOD. RESEARCH METHOD.

  3. Performance evaluation of self-breakdown-based single-gap ...

    Indian Academy of Sciences (India)

    gap plasma cathode electron (PCE) gun (5–20 kV/50–160 A) in argon, gas atmosphere and its performance evaluation based on particle-in-cell (PIC) simulation code `OOPIC-Pro'.The PCE-Gun works in conducting phase (low energy, high ...

  4. Performance Evaluation of a Mobile Wireless Computational Grid ...

    African Journals Online (AJOL)

    This work developed and simulated a mathematical model for a mobile wireless computational Grid architecture using networks of queuing theory. This was in order to evaluate the performance of theload-balancing three tier hierarchical configuration. The throughput and resource utilizationmetrics were measured and the ...

  5. Performance evaluation of commercial radionuclide calibrators in Indonesian hospitals

    International Nuclear Information System (INIS)

    Candra, Hermawan; Marsoem, Pujadi; Wurdiyanto, Gatot

    2012-01-01

    Dose calibrator is one of the supporting equipments in the field of nuclear medicine. At the hospitals, dose calibrator is used for activity measurement of radiopharmaceutical before it is administered to patients. Comparison of activity measurements of 131 I and 99m Tc with dose calibrators was organized in Indonesia during 2007–2010 with the the aim of obtaining information dose calibrator performance in the hospitals. Seven Indonesian hospitals participated in this comparison. The measurement results were evaluated using the E n criteria. The result presented in this paper facilitated the evaluation of dose calibrator performance at several hospitals. - Highlights: ► National comparisons of 131 I and 99m Tc radionuclides in Indonesian hospitals. ► Standardization using a Centronic IG11/A20 4πγ Ionization Chamber and participants using commercial radionuclide calibrators. ► Performance radionuclide calibrator in nuclear medicine in Indonesia. ► Measurement of activity of 99m Tc and 131 I was found satisfactory.

  6. Fiscal year 1998 Battelle performance evaluation agreement revision 1

    Energy Technology Data Exchange (ETDEWEB)

    DAVIS, T.L.

    1998-10-22

    Fiscal Year 1998 represents the second full year utilizing a results-oriented, performance-based contract. This document describes the critical outcomes, objectives, performance indicators, expected levels of performance, and the basis for the evaluation of the Contractors performance for the period October 1, 1997 through September 30, 1998, as required by Articles entitled Use of Objective Standards of Performance, Self Assessment and Performance Evaluation and Critical Outcomes Review of the Contract DE-AC08-76RLO1830. In partnership with the Contractor and other key customers, the Department of Energy (DOE) Richland Operations Office has defined six critical outcomes that same as the core for the Contractors performance evaluation. The Contractor also utilizes these outcomes as a basis for overall management of the Laboratory. As stated above six critical outcomes have been established for FY 1998. These outcomes are based on the following needs identified by DOE-HQ, RL and other customers of the Laboratory. Our Energy Research customer desires relevant, quality and cost effective science. Our Environmental Management customer wants technology developed, demonstrated, and deployed to solve environmental cleanup issues. To ensure the diversification and viability of the Laboratory as a National asset, RL and HQ alike want to increase the Science and Technical contributions of PNNL related to its core capabilities. RL wants improved leadership/management, cost-effective operations, and maintenance of a work environment, which fosters innovative thinking and high morale. RL and HQ alike desire compliance with environment, safety and health (ES and H) standards and disciplined conduct of operations for protection of the worker, environment, and the public, As with all of Hanford, DOE expects contribution of the Laboratory to the economic development of the Tri-Cities community, and the region, to build a new local economy that is less reliant on the Hanford mission

  7. Performance evaluation of photovoltaic systems on Kuwaiti schools’ rooftop

    International Nuclear Information System (INIS)

    Al-Otaibi, A.; Al-Qattan, A.; Fairouz, F.; Al-Mulla, A.

    2015-01-01

    Highlights: • Evaluation of rooftop PV installations at 2 Kuwaiti schools was carried out. • Lack of real plants data in the region and specifically Kuwait motivated the work. • Automated cleaning system allowed for minimization of soiling loss. • The average PV system performance was greater than 76%. • Schools show high potential for rooftop installations. - Abstract: Photovoltaic (PV) is a high-potential renewable energy technology for Kuwait to pursue due to high daily irradiation, and has garnered local attention in recent years due to the growing energy demand and concerns over climate change. As yet, no data are available regarding the actual performance of PV systems in Kuwait’s harsh environment. This paper presents a 12-month-long performance evaluation of the first 85.05 kW p and 21.6 kW p copper indium gallium selenide (CIGS) thin film, grid-connected PV systems on the rooftops of two schools. The schools’ monthly energy consumption and PV generation profiles, the actual performance of the PV plants, the effectiveness of automated cleaning systems on the power output, and the benefits of PV implementation in schools were analyzed and evaluated. Data analysis was applied to filter and normalize the data in order to identify the actual performance parameters. The findings of the study, based on solar irradiation collected, the performance of the module technology and the effectiveness of the automated cleaning systems, show that the performance ratio was maintained between 0.74 and 0.85. Furthermore, the minimum monthly energy yield of the PV systems was about 104 kW h/kW p . The annual average daily final yields of the PV systems in this study were 4.5 kW h/kW p /day. The results provided insight into the performance of CIGS grid-connected PV systems in Kuwait, and those data will be beneficial to the PV research community worldwide. School buildings, particularly for the rooftops, are a unique and important asset for urban PV system

  8. Evaluation of Performance of Investment Funds Based on Decision Models (DEA

    Directory of Open Access Journals (Sweden)

    Alireza Samet

    2016-12-01

    Full Text Available Selection of a suitable investment funds is very important from investors' point of view and may have a significant impact on the profit or loss of the funds. Therefore, evaluation of performance of investment funds to choose the most suitable fund will be given special emphasis. One of the new techniques for evaluating the performance of the Funds based on efficiency is the Data Envelopment Analysis technique. Accordingly, the present study is aimed to analyze and evaluate the performance of investment Funds in capital market of Iran, using the technique of efficiency evaluation through data envelopment analysis technique (DEA. This research is a descriptive - applicable study and to analyze the efficiency and effectiveness, 53 investment funds in the capital market of Iran in 2013 were considered as the sample. To analyze the efficiency of these funds, data envelopment analysis (DEA is used. Research findings showed that in 2013, of a total of 53 examined funds, 11 funds were in the efficiency situation and the other 42 funds were in a state of inefficiency. Also the reference funds and virtual composited funds of all inefficient funds were evaluated.

  9. Establishment and application of performance evaluation model for collection and transportation system of municipal solid waste

    Institute of Scientific and Technical Information of China (English)

    彭绪亚; 林晓东; 贾传兴; 王渝昆; 黄媛媛

    2009-01-01

    On the basis of analyzing the typical waste collection and transportation mode,the evaluation index system for performance of the waste collection and transportation system was proposed with three grades,which related to six factors,such as economic evaluation,high efficient evaluation,environmental impact assessment,resource evaluation,evaluation of security and emergency,evaluation of management and society. With the performance evaluation theory,the performance evaluation model of waste collection and transportation system was constructed,which quantified the grading standard of index and determined the index weight in analytic hierarchy process (AHP). After evaluating the waste collection and transportation system of the main districts of Chongqing city,the results show that the it has an excellent performance evaluation grade with very high performance level of three indices involving evaluation of management and society,environmental impact assessment,evaluation of security and emergency and quite low performance level of two indices that include high efficient evaluation and economic evaluation.

  10. Evaluation of emergency department performance - a systematic review on recommended performance and quality-in-care measures.

    Science.gov (United States)

    Sørup, Christian Michel; Jacobsen, Peter; Forberg, Jakob Lundager

    2013-08-09

    Evaluation of emergency department (ED) performance remains a difficult task due to the lack of consensus on performance measures that reflects high quality, efficiency, and sustainability. To describe, map, and critically evaluate which performance measures that the published literature regard as being most relevant in assessing overall ED performance. Following the PRISMA guidelines, a systematic literature review of review articles reporting accentuated ED performance measures was conducted in the databases of PubMed, Cochrane Library, and Web of Science. Study eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. A number of articles addresses this study's objective (n = 14 of 46 unique hits). Time intervals and patient-related measures were dominant in the identified performance measures in review articles from US, UK, Sweden and Canada. Length of stay (LOS), time between patient arrival to initial clinical assessment, and time between patient arrivals to admission were highlighted by the majority of articles. Concurrently, "patients left without being seen" (LWBS), unplanned re-attendance within a maximum of 72 hours, mortality/morbidity, and number of unintended incidents were the most highlighted performance measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study's results allow for advancement towards improved performance measurement and

  11. Performance evaluation on vacuum pumps using nanolubricants

    Energy Technology Data Exchange (ETDEWEB)

    Lue, Yeou Feng; Hsu, Yu Chun; Teng, Tun Ping [Dept. of Industrial EducationNational Taiwan Normal University, Taiwan (China)

    2016-09-15

    This study produced alumina (Al{sub 2}O{sub 3}) nanovacuum-pump lubricants (NVALs) by involving the dispersion of Al{sub 2}O{sub 3} nanoparticles in a vacuum-pump lubricant (VAL) with oleic as a dispersant. Experiments were conducted to evaluate the suspension performance, thermal conductivity, viscosity, specific heat, tribological performance and vacuum-pump performance of the NVALs. The experimental results obtained from the vacuum-pump performance tests show that the NVALs with Al{sub 2}O{sub 3} concentration of 0.2 wt.% and oleic concentration of 0.025 wt.% yielded the lowest electricity consumption, conserving 2.39% of electricity compared with the VAL. No marked difference was observed between the temperatures of the vacuum pump using VAL and NVAL. Furthermore, evacuation (i.e., the minimal pressure of -99.5 kPa) was reached faster by the vacuum pump with the NVALs, and the evacuation time could be reduced by 4.91% under optimal conditions. In addition, the vacuum pump with the NVALs exhibited superior overall effectiveness under relatively lower ambient temperatures.

  12. Performance evaluations of a geothermal power plant

    International Nuclear Information System (INIS)

    Coskun, C.; Oktay, Z.; Dincer, I.

    2011-01-01

    Thermodynamic analysis of an operational 7.5 MWe binary geothermal power plant in Tuzla-Turkey is performed, through energy and exergy, using actual plant data to assess its energetic and exergetic performances. Eight performance-related parameters, namely total exergy destruction ratio, component exergy destruction ratio, dimensionless exergy destruction, energetic renewability ratio, exergetic renewability ratio, energetic reinjection ratio, exergetic reinjection ratio and improvement potential are investigated. Energy and exergy losses/destructions for the plant and its units are determined and illustrated using energy and exergy flow diagrams. The largest energy and exergy losses occur in brine reinjection unit. The variation of the plant energy efficiency is found between 6% and 12%. Exergy efficiency values change between 35 and 49%. The annual average energy and exergy efficiencies are found as 9.47% and 45.2%, respectively. - Highlights: → Investigation of a geothermal system energetically and exergetically. → Performance assessment of the system through energy and exergy efficiencies. → Utilization of temperature distribution in exergy calculations. → Evaluation of eight energetic and exergetic parameters for the system.

  13. Monitoring and Evaluating Government Performance in Botswana

    Directory of Open Access Journals (Sweden)

    E. K. Botlhale

    2015-03-01

    Full Text Available In an era characterised by fiscal stress in the post-global recession era, clichés such as ‘bang for the buck’ are commonplace. Governments are under increasing pressure to spend limited public resources in efficient and  effective ways. Efficient and  effective governments are a necessary, though not sufficient, condition for economic development. Hence, governments have adopted performance-improving interventions such as New Public Management. Botswana jumped into the bandwagon of public sector reforms in the 1990s through interventions such as Performance-based Management Systems. The focus was almost entirely on performance enhancement to the neglect of performance measurement through a result-based Monitoring and Evaluation (M&E framework. However, in 2009, the government decided to mainstream M&E into the development planning regime. Since the M&E tool is still in draft form, Botswana is very favourably circumstanced to learn from others. Meanwhile essentials to do are: attitudinal change, shared vision on M&E, stakeholder management and demand and use of M&E information by policy-makers such as Members of Parliament.

  14. Facility/equipment performance evaluation using microcomputer simulation analysis

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.

    1985-08-01

    A computer simulation analysis model was developed at the Pacific Northwest Laboratory to assist in assuring the adequacy of the Monitored Retrievable Storage facility design to meet the specified spent nuclear fuel throughput requirements. The microcomputer-based model was applied to the analysis of material flow, equipment capability and facility layout. The simulation analysis evaluated uncertainties concerning both facility throughput requirements and process duration times as part of the development of a comprehensive estimate of facility performance. The evaluations provided feedback into the design review task to identify areas where design modifications should be considered

  15. Documenting Teacher Candidates' Professional Growth through Performance Evaluation

    Science.gov (United States)

    Brown, Elizabeth Levine; Suh, Jennifer; Parsons, Seth A.; Parker, Audra K.; Ramirez, Erin M.

    2015-01-01

    In the United States, colleges of education are responding to demands for increased accountability. The purpose of this article is to describe one teacher education program's implementation of a performance evaluation tool during final internship that measures teacher candidates' development across four domains: Planning and Preparation,…

  16. 45 CFR 2522.700 - How does evaluation differ from performance measurement?

    Science.gov (United States)

    2010-10-01

    ... service or not participating in a program. For example, an evaluation of a literacy program may compare... 45 Public Welfare 4 2010-10-01 2010-10-01 false How does evaluation differ from performance...) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE AMERICORPS PARTICIPANTS, PROGRAMS, AND APPLICANTS Evaluation...

  17. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  18. Standardizing the performance evaluation of short-term wind prediction models

    DEFF Research Database (Denmark)

    Madsen, Henrik; Pinson, Pierre; Kariniotakis, G.

    2005-01-01

    Short-term wind power prediction is a primary requirement for efficient large-scale integration of wind generation in power systems and electricity markets. The choice of an appropriate prediction model among the numerous available models is not trivial, and has to be based on an objective...... evaluation of model performance. This paper proposes a standardized protocol for the evaluation of short-term wind-poser preciction systems. A number of reference prediction models are also described, and their use for performance comparison is analysed. The use of the protocol is demonstrated using results...... from both on-shore and off-shore wind forms. The work was developed in the frame of the Anemos project (EU R&D project) where the protocol has been used to evaluate more than 10 prediction systems....

  19. Project Startup: Evaluating the Performance of Hydraulic Hybrid Refuse Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    The Fleet Test and Evaluation Team at the National Renewable Energy Laboratory (NREL) is evaluating the in-service performance of 10 next-generation hydraulic hybrid refuse vehicles (HHVs), 8 previous-generation HHVs, and 8 comparable conventional diesel vehicles operated by Miami-Dade County's Public Works and Waste Management Department in southern Florida. The HHVs under study - Autocar E3 refuse trucks equipped with Parker Hannifin's RunWise Advanced Series Hybrid Drive systems - can recover as much as 70 percent of the energy typically lost during braking and reuse it to power the vehicle. NREL's evaluation will assess the performance of this technology in commercial operation and help Miami-Dade County determine the ideal routes for maximizing the fuel-saving potential of its HHVs.

  20. Evaluation Method for Low-Temperature Performance of Lithium Battery

    Science.gov (United States)

    Wang, H. W.; Ma, Q.; Fu, Y. L.; Tao, Z. Q.; Xiao, H. Q.; Bai, H.; Bai, H.

    2018-05-01

    In this paper, the evaluation method for low temperature performance of lithium battery is established. The low temperature performance level was set up to determine the best operating temperature range of the lithium battery using different cathode materials. Results are shared with the consumers for the proper use of lithium battery to make it have a longer service life and avoid the occurrence of early rejection.

  1. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  2. Multicriterial ranking approach for evaluating bank branch performance

    NARCIS (Netherlands)

    Aleskerov, F; Ersel, H; Yolalan, R

    14 ranking methods based on multiple criteria are suggested for evaluating the performance of the bank branches. The methods are explained via an illustrative example, and some of them are applied to a real-life data for 23 retail bank branches in a large-scale private Turkish commercial bank.

  3. Evaluating the performance of Leucaena accessions for agroforestry ...

    African Journals Online (AJOL)

    The performance of Leucaena accessions on acid soils in eastern coast Tanzania for agroforestry was evaluated for three years. Plant tree parameters assessed were fodder yield and plant stem height, stem girth, the number of total branches and poles production. Also, Leucaena psyllid, a common pest threatening the ...

  4. Performance evaluation of domestic prototype dose area product meter SFT-1

    International Nuclear Information System (INIS)

    Lee, Ho Sun; Han, Seong Gyu; Roh, Young Roh; Lim, Hyun Jong; Kim, Jung Min; Kim, Jong Uk; Chae, Hyun Sik; Yoon, Yong Su

    2016-01-01

    The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R and BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product. Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatabilit y coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria

  5. Performance evaluation of nonhomogeneous hospitals: the case of Hong Kong hospitals.

    Science.gov (United States)

    Li, Yongjun; Lei, Xiyang; Morton, Alec

    2018-02-14

    Throughout the world, hospitals are under increasing pressure to become more efficient. Efficiency analysis tools can play a role in giving policymakers insight into which units are less efficient and why. Many researchers have studied efficiencies of hospitals using data envelopment analysis (DEA) as an efficiency analysis tool. However, in the existing literature on DEA-based performance evaluation, a standard assumption of the constant returns to scale (CRS) or the variable returns to scale (VRS) DEA models is that decision-making units (DMUs) use a similar mix of inputs to produce a similar set of outputs. In fact, hospitals with different primary goals supply different services and provide different outputs. That is, hospitals are nonhomogeneous and the standard assumption of the DEA model is not applicable to the performance evaluation of nonhomogeneous hospitals. This paper considers the nonhomogeneity among hospitals in the performance evaluation and takes hospitals in Hong Kong as a case study. An extension of Cook et al. (2013) [1] based on the VRS assumption is developed to evaluated nonhomogeneous hospitals' efficiencies since inputs of hospitals vary greatly. Following the philosophy of Cook et al. (2013) [1], hospitals are divided into homogeneous groups and the product process of each hospital is divided into subunits. The performance of hospitals is measured on the basis of subunits. The proposed approach can be applied to measure the performance of other nonhomogeneous entities that exhibit variable return to scale.

  6. Bridging the data gaps in the epidemiology of hepatitis C virus infection in Malaysia using multi-parameter evidence synthesis.

    Science.gov (United States)

    McDonald, Scott A; Mohamed, Rosmawati; Dahlui, Maznah; Naning, Herlianna; Kamarulzaman, Adeeba

    2014-11-07

    Collecting adequate information on key epidemiological indicators is a prerequisite to informing a public health response to reduce the impact of hepatitis C virus (HCV) infection in Malaysia. Our goal was to overcome the acute data shortage typical of low/middle income countries using statistical modelling to estimate the national HCV prevalence and the distribution over transmission pathways as of the end of 2009. Multi-parameter evidence synthesis methods were applied to combine all available relevant data sources - both direct and indirect - that inform the epidemiological parameters of interest. An estimated 454,000 (95% credible interval [CrI]: 392,000 to 535,000) HCV antibody-positive individuals were living in Malaysia in 2009; this represents 2.5% (95% CrI: 2.2-3.0%) of the population aged 15-64 years. Among males of Malay ethnicity, for 77% (95% CrI: 69-85%) the route of probable transmission was active or a previous history of injecting drugs. The corresponding proportions were smaller for male Chinese and Indian/other ethnic groups (40% and 71%, respectively). The estimated prevalence in females of all ethnicities was 1% (95% CrI: 0.6 to 1.4%); 92% (95% CrI: 88 to 95%) of infections were attributable to non-drug injecting routes of transmission. The prevalent number of persons living with HCV infection in Malaysia is estimated to be very high. Low/middle income countries often lack a comprehensive evidence base; however, evidence synthesis methods can assist in filling the data gaps required for the development of effective policy to address the future public health and economic burden due to HCV.

  7. Performance evaluation of an automotive thermoelectric generator

    Science.gov (United States)

    Dubitsky, Andrei O.

    Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.

  8. Performance Evaluation of a Multipurpose Bare PC Gateway

    DEFF Research Database (Denmark)

    Tsetse, Anthony; Appiah-Kubi, Patrick; Loukili, Alae

    2015-01-01

    . Different solutions (6to4 tunneling, IVI translation, NAT64, DNS64 etc.), have being proposed but these are all standalone systems. In this paper we discuss the design,implementation and performance evaluation of a multipurpose Bare PC Gateway which incorporates Network Address translation (NAT), 6to4...... results indicate a relatively better performance (18%-45%) of the Bare PC gateway compared to a Linux gateway (running the functionalities as standalone systems). We believe the proposed solution could easily scale to wide area networks and also provide a cost efficient solution...

  9. Impact of Diffusion and Variability on Vendor Performance Evaluation

    National Research Council Canada - National Science Library

    Doerr, Kenneth; Lewis, Ira

    2005-01-01

    In this paper we develop a theory of the impact of behavioral decision making factors on the evaluation of logistic service providers under performance-based logistics and provide an analysis of pilot...

  10. Business games: evaluating the financial performance of companies using AHP

    Directory of Open Access Journals (Sweden)

    Fabiano Cunha Marinho

    2017-08-01

    Full Text Available The business environment is permeated by uncertainty and volatility, making the activities related to the ever-challenging decision making for administrators. In the current context, it is fundamental premise for continuous evaluation of the assets applied in the organizations, be they of any segment or size. This article aims to evaluate the financial performance of companies in a simulated environment in business games by Analytic Hierarchy Process (AHP using as a base the analysis of current liquidity ratios, profitability and apital structure, demonstrating, through these indices, the industry involved in the game that obtained the best performance.

  11. Performance evaluation approach for the supercritical helium cold circulators of ITER

    Energy Technology Data Exchange (ETDEWEB)

    Vaghela, H.; Sarkar, B.; Bhattacharya, R.; Kapoor, H. [ITER-India, Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar-382428 (India); Chalifour, M.; Chang, H.-S.; Serio, L. [ITER Organization, Route de Vinon sur Verdon - 13115 St Paul Lez Durance (France)

    2014-01-29

    The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe cold circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.

  12. Identifying and Evaluating Options for Improving Sediment Management and Fish Passage at Hydropower Dams in the Lower Mekong River Basin

    Science.gov (United States)

    Wild, T. B.; Reed, P. M.; Loucks, D. P.

    2015-12-01

    The Mekong River basin in Southeast Asia is undergoing intensive and pervasive hydropower development to satisfy demand for increased energy and income to support its growing population of 60 million people. Just 20 years ago this river flowed freely. Today some 30 large dams exist in the basin, and over 100 more are being planned for construction. These dams will alter the river's natural water, sediment and nutrient flows, thereby impacting river morphology and ecosystems, and will fragment fish migration pathways. In doing so, they will degrade one of the world's most valuable and productive freshwater fish habitats. For those dams that have not yet been constructed, there still exist opportunities to modify their siting, design and operation (SDO) to potentially achieve a more balanced set of tradeoffs among hydropower production, sediment/nutrient passage and fish passage. We introduce examples of such alternative SDO opportunities for Sambor Dam in Cambodia, planned to be constructed on the main stem of the Mekong River. To evaluate the performance of such alternatives, we developed a Python-based simulation tool called PySedSim. PySedSim is a daily time step mass balance model that identifies the relative tradeoffs among hydropower production, and flow and sediment regime alteration, associated with reservoir sediment management techniques such as flushing, sluicing, bypassing, density current venting and dredging. To date, there has been a very limited acknowledgement or evaluation of the significant uncertainties that impact the evaluation of SDO alternatives. This research is formalizing a model diagnostic assessment of the key assumptions and parametric uncertainties that strongly influence PySedSim SDO evaluations. Using stochastic hydrology and sediment load data, our diagnostic assessment evaluates and compares several Sambor Dam alternatives using several performance measures related to energy production, sediment trapping and regime alteration, and

  13. How Does Procedural Fairness Affect Performance Evaluation System Satisfaction? (Evidence from a UK Police Force

    Directory of Open Access Journals (Sweden)

    Sholihin Mahfud

    2013-12-01

    Full Text Available This paper investigates whether, and if so, how procedural fairness affects performance evaluation system satisfaction in a UK Police Force. Employing a survey method with samples of detective inspectors and detective chief inspectors with significant managerial responsibilities in a UK Police Force, this study finds that procedural fairness affects performance evaluation system satisfaction. Further analysis reveals that the effect of procedural fairness on performance evaluation system satisfaction is mediated by trust. This study provides empirical evidence on how procedural fairness affects performance evaluation system satisfaction. The results of this study may benefit the designer of performance evaluation systems in police organizations.

  14. Basic considerations for the preparation of performance testing materials as related to performance evaluation acceptance criteria

    International Nuclear Information System (INIS)

    McCurdy, D.E.; Morton, J.S.

    2001-01-01

    The preparation of performance testing (PT) materials for environmental and radiobioassay applications involves the use of natural matrix materials containing the analyte of interest, the addition (spiking) of the analyte to a desired matrix (followed by blending for certain matrices) or a combination of the two. The distribution of the sample analyte concentration in a batch of PT samples will reflect the degree of heterogeneity of the analyte in the PT material and/or the reproducibility of the sample preparation process. Commercial and government implemented radioanalytical performance evaluation programs have a variety of acceptable performance criteria. The performance criteria should take into consideration many parameters related to the preparation of the PT materials including the within and between sample analyte heterogeneity, the accuracy of the quantification of an analyte in the PT material and to what 'known' value will a laboratory's result be compared. How sample preparation parameters affect the successful participation in performance evaluation (PE) programs having an acceptance criteria established as a percent difference from a 'known' value or in PE programs using other acceptance criteria, such as the guidance provided in ANSI N42.22 and N13.30 is discussed. (author)

  15. Performance evaluation of sprinkler irrigation system at Mambilla ...

    African Journals Online (AJOL)

    Variation in discharge can also be adjusted via use of uniform laterals, risers, and nozzles. This study further recommends an incorporation of a soil and water laboratory for the company to aid in monitoring the soil and water quality of the irrigation area. Keywords: Tea, irrigation System, Performance Evaluation ...

  16. Evaluation of the coagulometer STA R Max® (Stago) for routine coagulation parameters.

    Science.gov (United States)

    Brulé, Justine; Sinegre, Thomas; Pereira, Bruno; Berger, Marc G; Serre-Sapin, Anne-Françoise; Lebreton, Aurélien

    2018-04-01

    The STA R Max ® is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max ® is equipped with an innovative software (STA Coag Expert ® ) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max ® analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.

  17. The Search Performance Evaluation and Prediction in Exploratory Search

    OpenAIRE

    LIU, FEI

    2016-01-01

    The exploratory search for complex search tasks requires an effective search behavior model to evaluate and predict user search performance. Few studies have investigated the relationship between user search behavior and search performance in exploratory search. This research adopts a mixed approach combining search system development, user search experiment, search query log analysis, and multivariate regression analysis to resolve the knowledge gap. Through this study, it is shown that expl...

  18. An Application of the Impact Evaluation Process for Designing a Performance Measurement and Evaluation Framework in K-12 Environments

    Science.gov (United States)

    Guerra-Lopez, Ingrid; Toker, Sacip

    2012-01-01

    This article illustrates the application of the Impact Evaluation Process for the design of a performance measurement and evaluation framework for an urban high school. One of the key aims of this framework is to enhance decision-making by providing timely feedback about the effectiveness of various performance improvement interventions. The…

  19. Performance evaluation of effluent treatment plant for automobile industry

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Farid [Department of Applied Science and Humanities, PDM College of Engineering, Bahadurgarh (Haryana) (India); Pandey, Yashwant K. [School of Energy and Environmental Studies, Devi Ahilya Vishwavidyalaya, Indore (India); Kumar, P.; Pandey, Priyanka [Department of Environmental Science, Post Graduate College Ghazipur (IN

    2013-07-01

    The automobile industry’s wastewater not only contains high levels of suspended and total solids such as oil, grease, dyestuff, chromium, phosphate in washing products, and coloring, at various stages of manufacturing but also, a significant amount of dissolved organics, resulting in high BOD or COD loads. The study reveals the performance, evaluation and operational aspects of effluent treatment plant and its treatability, rather than the contamination status of the real property. The Results revealed that the treated effluent shows most of the parameters are within permissible limits of Central Pollution Control Board (CPCB), India and based on the site visits, discussion with operation peoples, evaluation of process design, treatment system, existing effluent discharge, results of sample analyzed and found that effluent treatment plant of automobile industry are under performance satisfactory.

  20. Containment performance evaluation for the GESSAR-II plant for seismic initiating events

    International Nuclear Information System (INIS)

    Shiu, K.K.; Chu, T.; Ludewig, H.; Pratt, W.T.

    1986-01-01

    As a part of the overall effort undertaken by Brookhaven National Laboratory (BNL) to review the GESSAR-II probabilistic risk assessment, an independent containment performance evaluation was performed using the containment event tree approach. This evaluation focused principally on those accident sequences which are initiated by seismic events. This paper reports the findings of this study. 1 ref

  1. Evaluation of Classifier Performance for Multiclass Phenotype Discrimination in Untargeted Metabolomics.

    Science.gov (United States)

    Trainor, Patrick J; DeFilippis, Andrew P; Rai, Shesh N

    2017-06-21

    Statistical classification is a critical component of utilizing metabolomics data for examining the molecular determinants of phenotypes. Despite this, a comprehensive and rigorous evaluation of the accuracy of classification techniques for phenotype discrimination given metabolomics data has not been conducted. We conducted such an evaluation using both simulated and real metabolomics datasets, comparing Partial Least Squares-Discriminant Analysis (PLS-DA), Sparse PLS-DA, Random Forests, Support Vector Machines (SVM), Artificial Neural Network, k -Nearest Neighbors ( k -NN), and Naïve Bayes classification techniques for discrimination. We evaluated the techniques on simulated data generated to mimic global untargeted metabolomics data by incorporating realistic block-wise correlation and partial correlation structures for mimicking the correlations and metabolite clustering generated by biological processes. Over the simulation studies, covariance structures, means, and effect sizes were stochastically varied to provide consistent estimates of classifier performance over a wide range of possible scenarios. The effects of the presence of non-normal error distributions, the introduction of biological and technical outliers, unbalanced phenotype allocation, missing values due to abundances below a limit of detection, and the effect of prior-significance filtering (dimension reduction) were evaluated via simulation. In each simulation, classifier parameters, such as the number of hidden nodes in a Neural Network, were optimized by cross-validation to minimize the probability of detecting spurious results due to poorly tuned classifiers. Classifier performance was then evaluated using real metabolomics datasets of varying sample medium, sample size, and experimental design. We report that in the most realistic simulation studies that incorporated non-normal error distributions, unbalanced phenotype allocation, outliers, missing values, and dimension reduction

  2. Evaluation of the main parameters affecting seismic performance of ...

    Indian Academy of Sciences (India)

    The current study considers forty eight (48) 3-D RC building models to .... Acceptance criteria for members and performance level criteria for buildings are ..... Evaluation and Retrofit of Concrete Buildings, Applied Technology Council, Vol 1.

  3. Performance Evaluation of Indian Technical Institutions Using PROMETHEE-GAIA Approach

    Science.gov (United States)

    Ranjan, Rajeev; Chakraborty, Shankar

    2015-01-01

    It has now become an important issue to evaluate the performance of technical institutions to develop better research and enrich the existing teaching processes. The results of such performance appraisal would serve as a reference point for decisions to choose a particular institution, hire manpower, and provide financial support for the…

  4. 78 FR 41926 - Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on...

    Science.gov (United States)

    2013-07-12

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OECA-2013-0413; FRL--9832-8] Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on Wastewater Laboratories (Renewal); EPA... request (ICR), ``Performance Evaluation Studies on Wastewater Laboratories'' (EPA ICR No. 0234.11, OMB...

  5. TEACHER PERFORMANCE EVALUATION

    Directory of Open Access Journals (Sweden)

    Guadalupe Iván Martínez-Chairez

    2015-07-01

    Full Text Available This research report comes from a study that was developed during the school years 2013-2014, 2014-2015, in the southern state of Chihuahua central region, in the education sector 25 consisting of five school zones that provide services to Meoqui municipalities, Julimes and Delicias. The study is a mixed court, correlational comprehensive sequential procedure. Some of the results is that there is a correlation between the 578 years of service of teachers and the score assigned to students in teaching career, but there is no association between teacher performance and the context in which it works, in addition there is no relationship between the teacher performance and school performance of students on standardized tests. 2.4% of the representative sample presented an excellent teacher performance, 7.3% have a bad teacher performance, but it is noteworthy that 39% of teachers observed lies with good teaching performance.

  6. Performance, Carcass Evaluation And Economics Of Production Of ...

    African Journals Online (AJOL)

    An eight-weeks feeding trial involving 162,8-week old goldline cockerel birds was carried out in a completely randomized design to evaluate the performance, carcass characteristics and economics of production of cockerels fed whole cassava plant meal (WCPM). Diet 1 was maize based and served as the control, diet 2 ...

  7. Development and performance evaluation of a guided horizontal ...

    African Journals Online (AJOL)

    ... and tested on the rice field of National Cereals Research Institute (NCRI), Moor plantation, Ibadan, to evaluate the performance of the machine. A 22 x 3 factorial experimental design with two replicates was used to analysis the effect of engine speed (1200, 1400 and 1800rpm), ecology (irrigated and rainfed-lowland) and ...

  8. An Agency Theory Perspective on Student Performance Evaluation

    Science.gov (United States)

    Smith, Michael E.; Zsidisin, George A.; Adams, Laural L.

    2005-01-01

    The emphasis in recent research on the responsibility of college and university business instructors to prepare students for future employment underscores a need to refine the evaluation of student performance. In this article, an agency theory framework is used to understand the trade-offs that may be involved in the selection of various…

  9. Clinical performance of a glass ionomer restorative system: a 6-year evaluation.

    Science.gov (United States)

    Gurgan, Sevil; Kutuk, Zeynep Bilge; Ergin, Esra; Oztas, Sema Seval; Cakir, Filiz Yalcin

    2017-09-01

    The aim of this study is to evaluate the long-term clinical performance of a glass ionomer (GI) restorative system in the restoration of posterior teeth compared with a micro-filled hybrid posterior composite. A total of 140 (80 Cl1 and 60 Cl2) lesions in 59 patients were restored with a GI system (Equia) or a micro hybrid composite (Gradia Direct). Restorations were evaluated at baseline and yearly during 6 years according to the modified-USPHS criteria. Negative replicas at each recall were observed under SEM to evaluate surface characteristics. Data were analyzed with Cohcran's Q and McNemar's tests (p evaluated in 47 patients with a recall rate of 79.6% at 6 years. Significant differences were found in marginal adaptation and marginal discoloration for both restorative materials for Cl1 and Cl2 restorations (p  0.05). A significant decrease in color match was observed in Equia restorations (p performance after 6 years. SEM evaluations were in accordance with the clinical findings. Both materials showed a good clinical performance for the restoration of posterior teeth during the 6-year evaluation. The clinical effectiveness of Equia and Gradia Direct Posterior was acceptable in Cl1 and Cl2 cavities subsequent to 6-year evaluation.

  10. Solar power plant performance evaluation: simulation and experimental validation

    Science.gov (United States)

    Natsheh, E. M.; Albarbar, A.

    2012-05-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  11. Evaluation of high-definition television for remote task performance

    International Nuclear Information System (INIS)

    Draper, J.V.; Fujita, Y.; Herndon, J.N.

    1987-04-01

    High-definition television (HDTV) transmits a video image with more than twice the number (1125 for HDTV to 525 for standard-resolution TV) of horizontal scan lines that standard-resolution TV provides. The improvement in picture quality (compared to standard-resolution TV) that the extra scan lines provide is impressive. Objects in the HDTV picture have more sharply defined edges, better contrast, and more accurate reproduction of shading and color patterns than do those in the standard-resolution TV picture. Because the TV viewing system is a key component for teleoperator performance, an improvement in TV picture quality could mean an improvement in the speed and accuracy with which teleoperators perform tasks. This report describes three experiments designed to evaluate the impact of HDTV on the performance of typical remote tasks. The performance of HDTV was compared to that of standard-resolution, monochromatic TV and standard-resolution, stereoscopic, monochromatic TV in the context of judgment of depth in a televised scene, visual inspection of an object, and performance of a typical remote handling task. The results of the three experiments show that in some areas HDTV can lead to improvement in teleoperator performance. Observers inspecting a small object for a flaw were more accurate with HDTV than with either of the standard-resolution systems. High resolution is critical for detection of small-scale flaws of the type in the experiment (a scratch on a glass bottle). These experiments provided an evaluation of HDTV television for use in tasks that must be routinely performed to remotely maintain a nuclear fuel reprocessing facility. 5 refs., 7 figs., 9 tabs

  12. On the role of computer-assisted evaluations (PHI, TCOG, Tmax and D/DTmax as parameters) of radionuclide cerebral function studies

    International Nuclear Information System (INIS)

    Stolte, P.

    1984-01-01

    With the aid of Fourier's analysis four new parameters - PHI, TCOG, Tmax and D/DTmax - were introduced, which are useful for radionuclide cerebral function studies in apoplexy, Prolonged Ischemic Neurological Deficiency (PRIND) and Transitory Ischemic Attack (TIA). The diagnostic accuracy and reproducibility of results obtained on the basis of these parameters were investigated in a study including 69 patients and subsequently compared with the findings revealed by conventional visual diagnostic procedures with or without multi-parameter analysis. Using the method described here, which basically constitutes a procedure to assess the dynamic factors pertinent to a disease, the pathological conditions mentioned above were diagnosed with an accuracy of 100%, provided that the evaluations were carried out by a sufficiently experienced investigator. In terms of sensitivity the procedure under investigation exceeded the usual visual methods of evaluation by 6.5% (in PRIND and TIA even by as much as 27%). (TRV) [de

  13. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  14. Modelling and evaluation of surgical performance using hidden Markov models.

    Science.gov (United States)

    Megali, Giuseppe; Sinigaglia, Stefano; Tonet, Oliver; Dario, Paolo

    2006-10-01

    Minimally invasive surgery has become very widespread in the last ten years. Since surgeons experience difficulties in learning and mastering minimally invasive techniques, the development of training methods is of great importance. While the introduction of virtual reality-based simulators has introduced a new paradigm in surgical training, skill evaluation methods are far from being objective. This paper proposes a method for defining a model of surgical expertise and an objective metric to evaluate performance in laparoscopic surgery. Our approach is based on the processing of kinematic data describing movements of surgical instruments. We use hidden Markov model theory to define an expert model that describes expert surgical gesture. The model is trained on kinematic data related to exercises performed on a surgical simulator by experienced surgeons. Subsequently, we use this expert model as a reference model in the definition of an objective metric to evaluate performance of surgeons with different abilities. Preliminary results show that, using different topologies for the expert model, the method can be efficiently used both for the discrimination between experienced and novice surgeons, and for the quantitative assessment of surgical ability.

  15. A performance evaluation of personnel identity verifiers

    International Nuclear Information System (INIS)

    Maxwell, R.L.; Wright, L.J.

    1987-01-01

    Personnel identity verification devices, which are based on the examination and assessment of a body feature or a unique repeatable personal action, are steadily improving. These biometric devices are becoming more practical with respect to accuracy, speed, user compatibility, reliability and cost, but more development is necessary to satisfy the varied and sometimes ill-defined future requirements of the security industry. In an attempt to maintain an awareness of the availability and the capabilities of identity verifiers for the DOE security community, Sandia Laboratories continues to comparatively evaluate the capabilities and improvements of developing devices. An evaluation of several recently available verifiers is discussed in this paper. Operating environments and procedures more typical of physical access control use can reveal performance substantially different from the basic laboratory tests

  16. Performance Evaluation Factors: Designing an Instrument for National Health Network in Iran

    Directory of Open Access Journals (Sweden)

    Sassan Ghorbani-Kalkhajeh

    2016-04-01

    Full Text Available As a systematic process for gathering and analyzing data, performance evaluation could be used as a valid method to highlight levels of success and to identify strength and weakness of ongoing programs. The aim of the present study was to develop an instrument for evaluating rural health centers in Iran. Based on related literature and experts’ views, eight crucial fields of performance evaluation, and a questionnaire including 100 items were formed. The participants of the study were 525 people having health related jobs in rural or urban health centers. Reliability and validity requirements were checked; exploratory and confirmatory factor analyses were used. Factor analysis identified 11 components which embraced 60 items. Components were named as planning, control, coordination, structure, setting and facilities, education, customers’ satisfaction, staff’s job satisfaction, disease surveillance, mother-child care, and effectiveness which are presented as a model for performance evaluation. The obtained instrument embraces all required factors suggested by experts and literature hence it can be used as an evaluation instrument in both rural and urban health centers.

  17. Manufacturing plant performance evaluation by discrete event simulation

    International Nuclear Information System (INIS)

    Rosli Darmawan; Mohd Rasid Osman; Rosnah Mohd Yusuff; Napsiah Ismail; Zulkiflie Leman

    2002-01-01

    A case study was conducted to evaluate the performance of a manufacturing plant using discrete event simulation technique. The study was carried out on animal feed production plant. Sterifeed plant at Malaysian Institute for Nuclear Technology Research (MINT), Selangor, Malaysia. The plant was modelled base on the actual manufacturing activities recorded by the operators. The simulation was carried out using a discrete event simulation software. The model was validated by comparing the simulation results with the actual operational data of the plant. The simulation results show some weaknesses with the current plant design and proposals were made to improve the plant performance. (Author)

  18. Performance evaluation of TDT soil water content and watermark soil water potential sensors

    Science.gov (United States)

    This study evaluated the performance of digitized Time Domain Transmissometry (TDT) soil water content sensors (Acclima, Inc., Meridian, ID) and resistance-based soil water potential sensors (Watermark 200, Irrometer Company, Inc., Riverside, CA) in two soils. The evaluation was performed by compar...

  19. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  20. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste: Volume 3, Site evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Waters, R.D.; Gruebel, M.M. [eds.

    1996-03-01

    A team of analysts designed and conducted a performance evaluation to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 2 provides details about the site-selection process, the performance-evaluation methodology, and the overall results of the analysis. Volume 3 contains detailed evaluations of the fifteen sites and discussion of the results for each site.

  1. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste: Volume 3, Site evaluations

    International Nuclear Information System (INIS)

    Waters, R.D.; Gruebel, M.M.

    1996-03-01

    A team of analysts designed and conducted a performance evaluation to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 2 provides details about the site-selection process, the performance-evaluation methodology, and the overall results of the analysis. Volume 3 contains detailed evaluations of the fifteen sites and discussion of the results for each site

  2. Development and performance evaluation of fiber reinforced polymer bridge.

    Science.gov (United States)

    2014-03-01

    Fiber reinforced polymers (FRP) have become more popular construction materials in the last decade due to the reduction of : material costs. The installation and performance evaluation of the first FRP-wrapped balsa wood bridge in Louisiana is descri...

  3. Lithium/Manganese Dioxide (Li/MnO(2)) Battery Performance Evaluation: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, D.; Clark, N.H.

    1999-04-01

    In February 1997, under the auspices of the Product Realization Program, an initiative to develop performance models for lithium/manganese dioxide-based batteries began. As a part of this initiative, the performance characteristics of the cells under a variety of conditions were determined, both for model development and for model validation. As a direct result of this work, it became apparent that possible Defense Program (DP) uses for batteries based on this cell chemistry existed. A larger effort aimed at mapping the performance envelope of this chemistry was initiated in order to assess the practicality of this cell chemistry, not only for DP applications, but also for other uses. The work performed included an evaluation of the cell performance as a function of a number of variables, including cell size, manufacturer, current, pulse loads, constant current loads, safety, etc. In addition, the development of new evaluation techniques that would apply to any battery system, such as those related to reliability assessments began. This report describes the results of these evaluations.

  4. Performance evaluation on vibration control of MR landing gear

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D Y; Nam, Y J; Park, M K [Graduate School, Pusan National University, Busan 609-735 (Korea, Republic of); Yamane, R [Kokushikan University, 4-28-1 Setagaya, Setagaya-ku, Tokyo 154-8515 (Japan)], E-mail: ldy5577@yahoo.co.kr, E-mail: mkpark1@pusan.ac.kr

    2009-02-01

    This paper is concerned with the applicability of the developed MR damper to the landing gear system for the attenuating undesired shock and vibration in the landing and taxing phases. First of all, the experimental model of the MR damper is derived based on the results of performance evaluations. Next, a simplified skyhook controller, which is one of the most straightforward, but effective approaches for improving ride comport in vehicles with active suspensions, is formulated. Then, the vibration control performances of the landing gear system using the MR damper are theoretically evaluated in the landing phase of the aircraft. A series of simulation analyses show that the proposed MR damper with the skyhook controller is effective for suppressing undesired vibration of the aircraft body. Finally, the effectiveness of the simulation results are additionally verified via HILS (Hardware-in-the-loop-simulation) method.

  5. EVALUATION OF HOTEL SERVICE-PERFORMANCE PROCESS IN BULGARIA

    Directory of Open Access Journals (Sweden)

    Georgina Lukanova

    2010-06-01

    Full Text Available The paper analyses the hotel service-performance process in Bulgarian hotels, which is based on the results of the research about tourists’ opinion on basic moments in service process. One of the most important characteristics of hotel industry is the leading role of the human factor in service-performance process. It cannot be accomplished without the participation of the customer and without the participation of the staff.This makes the evaluation of service process strongly subjective. Because of this, customer needs satisfaction is a big challenge for the hotel management. Under the present conditions of an increased competition, satisfying customers means offering service-performance process, which not only meets, but also exceeds guests’expectations. This can be achieved by a preliminary study of their requirements and expectations.

  6. [Analysis and evaluation of acute injuries in musical performers].

    Science.gov (United States)

    Wanke, E M; Groneberg, D A; Quarcoo, D

    2011-09-01

    Specific requirements in the Musical field such as the versatility of abilities in dancing, singing and acting, the aspiration for perfection as well as the high number of performances, lead to a high amount of occupational accidents not yet evaluated. Aim of this study is, therefore, to analyze and evaluate occupational accidents in Musical performers and to suggest preventive concepts. The data of this evaluation comprise occupational accident reports of consultants, accident reports of various Berlin theatres as well as case records of all Berlin State Theatres (n = 89, m: 58, f: 31) of the Berlin State Accident Insurance covering a period 12-year period. A total of 60.3 % of the accidents happen during performances, 24.4 % during rehearsals, and 6.7 % during the training. Lower extremity injuries (m: 61.1 %, f: 58.2 %) are the most common for performers. The majority of injuries (m: 46.3 %, f: 50.0 %) happens during ordinary dance movements. Altogether 66.7 % of the injuries have a uniquely defined exogenous cause. The dance partner is with 17.9 % the most common exogenous cause, followed by props (15.4 %) and dance floor (11.6 %). 66.3 % of all accidents happen in the first three hours after starting work with an incidence in the evenings. There are gender specific differences. Parallels can be drawn (e. g. injured structures, type of injuries) to the professional dance and the dance theatre, however, there are also differences (e. g. age, injury location) Due to the results and the work specific requirements the Musical is to be considered as an autonomous field among the performing arts. Above all, the majority of injuries are - compared to other dance styles - caused by exogenous factors. Modifications may here reduce the incidence. At that, an early interaction in the planning progress of a production, an optimal selection of physical and psychic qualified performers as well as an improvement of training conditions are primary steps towards

  7. Performance evaluation in assets management with the AHP

    Directory of Open Access Journals (Sweden)

    Luiz Flávio Autran Monteiro Gomes

    2012-04-01

    Full Text Available The main objective of this article is to develop a transparent and efficient model, using the AHP (Analytic Hierarchy Process method as a basis and applying the software SuperDecisions, which makes it possible to evaluate the performance of employees, aligning the individual objectives defined and the competences required for the organisational mission. The methodology used was of an investigative and exploratory nature, due to the need to increase knowledge on the use of the AHP in the process of classifying employee performance. Starting from a high performance culture, it is possible to highlight the employees who present the best performance and improve the remuneration policies, as well as invest in the training of the skills lacking in a clear and assertive manner. The results found in this research prove the viability of the respective application, which is directly related to the meeting of targets and, consequently,to sustaining competitiveness and increasing added value for shareholders.

  8. Development of Testing Methodologies to Evaluate Postflight Locomotor Performance

    Science.gov (United States)

    Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.; Bloomberg, J. J.

    2006-01-01

    Crewmembers experience locomotor and postural instabilities during ambulation on Earth following their return from space flight. Gait training programs designed to facilitate recovery of locomotor function following a transition to a gravitational environment need to be accompanied by relevant assessment methodologies to evaluate their efficacy. The goal of this paper is to demonstrate the operational validity of two tests of locomotor function that were used to evaluate performance after long duration space flight missions on the International Space Station (ISS).

  9. Evaluation of performance of barrier materials in geological disposal of radioactive waste

    International Nuclear Information System (INIS)

    Sasakura, Takeshi; Kobayashi, Ichizo

    2004-01-01

    It is important to evaluate the hydraulic and mechanical performance of barrier materials for geological disposal of radioactive waste. Many experiments on the hydraulic and mechanical performance of barrier materials have been implemented. However, both the ordinary water head-controlled permeability test for evaluating hydraulic performance and the oedometer test for obtaining the mechanical properties are usually needed. In this study, the flow pump permeability test was applied to various barrier materials with the purpose of quickly evaluating their hydraulic performance. The flow pump permeability test was shown to be applicable to every barrier material employed in this study, of which the coefficient of permeability ranged from 10-7 to 10-14 m/sec. The time needed to obtain the coefficient of permeability was about 1/8 that of ordinary head-controlled permeability tests. The resulting coefficient of permeability was more accurate than that from the standard water head-controlled permeability test. Moreover, the bentonite-engineered barrier materials were subjected to a constant strain rate consolidation test, which is a method to quickly evaluate the mechanical performance. The results of the consolidation tests were consistent with the results of the oedometer tests and the necessary time for the test was reduced to only four days even in case of Na-ben-tonite, for which a couple of months was necessary with the standard oedometer test. (author)

  10. Solar power plant performance evaluation: simulation and experimental validation

    International Nuclear Information System (INIS)

    Natsheh, E M; Albarbar, A

    2012-01-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P and O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  11. Performance evaluation of existing building structure with pushover analysis

    Science.gov (United States)

    Handana, MAP; Karolina, R.; Steven

    2018-02-01

    In the management of the infrastructure of the building, during the period of buildings common building damage as a result of several reasons, earthquakes are common. The building is planned to work for a certain service life. But during the certain service life, the building vulnerable to damage due to various things. Any damage to cultivate can be detected as early as possible, because the damage could spread, triggering and exacerbating the latest. The newest concept to earthquake engineering is Performance Based Earthquake Engineering (PBEE). PBEE divided into two, namely Performance Based Seismic Design (PBSD) and Performance Based Seismic Evaluation (PBSE). Evaluation on PBSE one of which is the analysis of nonlinear pushover. Pushover analysis is a static analysis of nonlinear where the influence of the earthquake plan on building structure is considered as burdens static catch at the center of mass of each floor, which it was increased gradually until the loading causing the melting (plastic hinge) first within the building structure, then the load increases further changes the shapes of post-elastic large it reached the condition of elastic. Then followed melting (plastic hinge) in the location of the other structured.

  12. Multiparameter Cell Cycle Analysis.

    Science.gov (United States)

    Jacobberger, James W; Sramkoski, R Michael; Stefan, Tammy; Woost, Philip G

    2018-01-01

    Cell cycle cytometry and analysis are essential tools for studying cells of model organisms and natural populations (e.g., bone marrow). Methods have not changed much for many years. The simplest and most common protocol is DNA content analysis, which is extensively published and reviewed. The next most common protocol, 5-bromo-2-deoxyuridine S phase labeling detected by specific antibodies, is also well published and reviewed. More recently, S phase labeling using 5'-ethynyl-2'-deoxyuridine incorporation and a chemical reaction to label substituted DNA has been established as a basic, reliable protocol. Multiple antibody labeling to detect epitopes on cell cycle regulated proteins, which is what this chapter is about, is the most complex of these cytometric cell cycle assays, requiring knowledge of the chemistry of fixation, the biochemistry of antibody-antigen reactions, and spectral compensation. However, because this knowledge is relatively well presented methodologically in many papers and reviews, this chapter will present a minimal Methods section for one mammalian cell type and an extended Notes section, focusing on aspects that are problematic or not well described in the literature. Most of the presented work involves how to segment the data to produce a complete, progressive, and compartmentalized cell cycle analysis from early G1 to late mitosis (telophase). A more recent development, using fluorescent proteins fused with proteins or peptides that are degraded by ubiquitination during specific periods of the cell cycle, termed "Fucci" (fluorescent, ubiquitination-based cell cycle indicators) provide an analysis similar in concept to multiple antibody labeling, except in this case cells can be analyzed while living and transgenic organisms can be created to perform cell cycle analysis ex or in vivo (Sakaue-Sawano et al., Cell 132:487-498, 2007). This technology will not be discussed.

  13. Study on evaluation index system of operational performance of municipal wastewater treatment plants in China

    Science.gov (United States)

    Xiaoxin, Zhang; Jin, Huang; Ling, Lin; Yan, Li

    2018-05-01

    According to the undeveloped evaluation method for the operational performance of the municipal wastewater treatment plants, this paper analyzes the policies related to sewage treatment industry based on the investigation of the municipal wastewater treatment plants. The applicable evaluation method for the operational performance was proposed from environmental protection performance, resources and energy consumption, technical and economic performance, production management and main equipment, providing a reliable basis for scientific evaluation of the operation as well as improving the operational performance of municipal wastewater treatment plant.

  14. Elastic FWI for VTI media: A synthetic parameterization study

    KAUST Repository

    Kamath, Nishant; Tsvankin, Ilya; Diaz, Esteban

    2016-01-01

    A major challenge for multiparameter full-waveform inversion (FWI) is the inherent trade-offs (or cross-talk) between model parameters. Here, we perform FWI of multicomponent data generated for a synthetic VTI (transversely isotropic with a vertical

  15. Quantitative multi-parameter mapping of R1, PD*, MT and R2* at 3T: a multi-center validation

    Directory of Open Access Journals (Sweden)

    Nikolaus eWeiskopf

    2013-06-01

    Full Text Available Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1mm high-resolution maps of the longitudinal relaxation rate (R1=1/T1, effective proton density (PD*, magnetization transfer saturation (MT and effective transverse relaxation rate (R2*=1/T2*. MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV for typical morphometric measures (i.e., gray matter probability maps used in voxel-based morphometry and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1% and 8%, respectively, except for the inter-site CoV of R2* (< 20%. The gray matter probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived gray matter probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.

  16. Performance Evaluation of UML2-Modeled Embedded Streaming Applications with System-Level Simulation

    Directory of Open Access Journals (Sweden)

    Arpinen Tero

    2009-01-01

    Full Text Available This article presents an efficient method to capture abstract performance model of streaming data real-time embedded systems (RTESs. Unified Modeling Language version 2 (UML2 is used for the performance modeling and as a front-end for a tool framework that enables simulation-based performance evaluation and design-space exploration. The adopted application meta-model in UML resembles the Kahn Process Network (KPN model and it is targeted at simulation-based performance evaluation. The application workload modeling is done using UML2 activity diagrams, and platform is described with structural UML2 diagrams and model elements. These concepts are defined using a subset of the profile for Modeling and Analysis of Realtime and Embedded (MARTE systems from OMG and custom stereotype extensions. The goal of the performance modeling and simulation is to achieve early estimates on task response times, processing element, memory, and on-chip network utilizations, among other information that is used for design-space exploration. As a case study, a video codec application on multiple processors is modeled, evaluated, and explored. In comparison to related work, this is the first proposal that defines transformation between UML activity diagrams and streaming data application workload meta models and successfully adopts it for RTES performance evaluation.

  17. Chemistry technician performance evaluation program Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Shawver, J.M.

    1992-01-01

    The Arizona Nuclear Power Project (ANPP), a three-reactor site located 50 miles west of Phoenix, Arizona, has developed and implemented a program for evaluating individual chemistry technician analytical performance on a routine basis. About 45 chemistry technicians are employed at the site, 15 at each operating unit. The technicians routinely perform trace level analyses for impurities of concern to PWRs. Each month a set of blind samples is provided by an outside vendor. The blind samples contain 16 parameters which are matrixed to approximate the PWR's primary and secondary cycles. Nine technicians receive the samples, three from each operating unit, and perform the required analyses. Acceptance criteria for successful performance on the blind parameters is based on the values found in the Institute of Nuclear Power Operations (INPO) Document 83-016, Revision 2, August 1989, Chemistry Quality Control Program. The goal of the program is to have each technician demonstrate acceptable performance on each of 16 analytical parameters. On completion of each monthly set, a summary report of all of the analytical results for the sample set is prepared. From the summary report, analytical bias can be detected, technician performance is documented, and overall laboratory performance can be evaluated. The program has been very successful at satisfying the INPO requirement that the analytical performance of each individual technician should be checked on at least a six-month frequency for all important parameters measured. This paper describes the program as implemented at the Palo Verde Nuclear Generating Station and provides a summary report and trend and bias graphs for illustrative purposes

  18. IPEP: Laboratory performance evaluation reports for management of DOE EM programs

    International Nuclear Information System (INIS)

    Hensley, J.E.; Lindahl, P.C.; Streets, W.E.

    1995-01-01

    Environmental restoration program/project managers at DOE's Office of Environmental Management (EM) are making important decisions based on analytical data generated by contracted laboratories. The Analytical Services Division, EM-263, is developing the Integrated Performance Evaluation Program (IPEP) to assess the performance of those laboratories, based on results from Performance Evaluation (PE) programs. The IPEP reports will be used by the laboratories to foster self-assessment and improvement. In addition, IPEP will produce PE reports for three levels of EM management (Operations/Project Offices, Area Program Offices, and Deputy Assistant Secretary Office). These reports will be used to assess whether contracted analytical laboratories have the capability to produce environmental data of the quality necessary for making environmental restoration and waste management decisions

  19. Evaluation of knowledge management performances in NULIFE network

    International Nuclear Information System (INIS)

    Nitoi, Mirela; Cojan, Mihai; Pavelescu, Margarit

    2009-01-01

    One of the objectives of Nuclear Plant Life Prediction (NULIFE) network is the identification of experts and resources which can be used in the future. The major challenge is to use these competent personnel in an efficient manner, in the network. The paper presents the necessity of developing the knowledge management strategy for networks of excellence, as the specific issues of NULIFE network. In order to highlight the progress during the project operating, the developed indicators of performance are specified. The developed questionnaires evaluate the quality of knowledge management (development, use and distribution of knowledge), type of knowledge which is considered important for organization (at present and in future) and the benefits of knowledge transfer (immediate and in perspective). The developed questionnaires permit along with the evaluation of others groups activities, an auto-evaluation for the activity of the group where the subject is involved. (authors)

  20. Instructors' Evaluation as an Instrument to Improve Performance and Determine Competence

    Science.gov (United States)

    Laei, Soosan; Abdi, Ali; Karamaerouz, Mohamad Javad; Shirkhani, Nassim

    2014-01-01

    Experts in human resources management have suggested common objectives for evaluating performance of all organizations, including motivation and improvement of staff performance, identification of competence and skills, identification of educational needs and developmental contexts, etc. Achievement to these objectives is -a responsibility of…

  1. Evaluation on current-limiting performance of the YBCO thin-film wire considering electric coupling condition

    International Nuclear Information System (INIS)

    Du, H.-I.; Han, B.-S.; Kim, Y.-J.; Lee, D.-H.; Song, S.-S.; Han, T.-H.; Han, S.-C.

    2011-01-01

    The basic way to improve the performance of a superconducting current limiter is to apply and evaluate a superconducting device that is appropriate to the superconducting current limiter. Among the many types of superconducting devices, the YBCO thin film wire has excellent current-limiting performance that is appropriate for actual system application. For the application of the YBCO thin film wire to superconducting current limiters, its current-limiting performance as a unit device must be accurately evaluated, and measures to improve its current-limiting performance must be sought. Accordingly, to evaluate the current-limiting performance of the YBCO thin film wire, this study was conducted to evaluate its resistance-increasing trend, V max , T r , I max , I qt , and current-limiting rate as a unit device, after which the electric coupling condition that consists of a core and windings was used to evaluate the current-limiting performance of the YBCO thin film wire.

  2. Performance Evaluation Tests for Environmental Research (PETER): evaluation of 114 measures

    Science.gov (United States)

    Bittner, A. C. Jr; Carter, R. C.; Kennedy, R. S.; Harbeson, M. M.; Krause, M.

    1986-01-01

    The goal of the Performance Evaluation Tests for Environmental Research (PETER) Program was to identify a set of measures of human capabilities for use in the study of environmental and other time-course effects. 114 measures studied in the PETER Program were evaluated and categorized into four groups based upon task stability and task definition. The Recommended category contained 30 measures that clearly obtained total stabilization and had an acceptable level of reliability efficiency. The Acceptable-But-Redundant category contained 15 measures. The 37 measures in the Marginal category, which included an inordinate number of slope and other derived measures, usually had desirable features which were outweighed by faults. The 32 measures in the Unacceptable category had either differential instability or weak reliability efficiency. It is our opinion that the 30 measures in the Recommended category should be given first consideration for environmental research applications. Further, it is recommended that information pertaining to preexperimental practice requirements and stabilized reliabilities should be utilized in repeated-measures environmental studies.

  3. Assessing Quality and Evaluating Performance in Higher Education: Worlds Apart or Complementary Views?

    Science.gov (United States)

    Sarrico, Claudia S.; Rosa, Maria J.; Teixeira, Pedro N.; Cardoso, Margarida F.

    2010-01-01

    This paper reflects on quality assessment and performance evaluation in higher education, namely by analysing the insufficient link between those two aspects. We start by reviewing the current state of the art regarding different processes and mechanisms of quality assessment and performance evaluation and discuss some of the major issues…

  4. MOL-Eye: A New Metric for the Performance Evaluation of a Molecular Signal

    OpenAIRE

    Turan, Meric; Kuran, Mehmet Sukru; Yilmaz, H. Birkan; Chae, Chan-Byoung; Tugcu, Tuna

    2017-01-01

    Inspired by the eye diagram in classical radio frequency (RF) based communications, the MOL-Eye diagram is proposed for the performance evaluation of a molecular signal within the context of molecular communication. Utilizing various features of this diagram, three new metrics for the performance evaluation of a molecular signal, namely the maximum eye height, standard deviation of received molecules, and counting SNR (CSNR) are introduced. The applicability of these performance metrics in th...

  5. Evaluation of Service Quality in Brewery Using Importance-Performance Analysis

    Directory of Open Access Journals (Sweden)

    Ingaldi Manuela

    2016-03-01

    Full Text Available Because of its specificity, service quality is difficult to assess, especially since there is no materiality in it, it cannot be seen. Usually the gap between the expectations of customer and their perceptions in relation to a particular service is observed. This article aim is to evaluate the quality of catering services offered by one of the breweries (restaurant in Silesia. The importance-performance analysis, which is often underestimated, was used in order to show its advantages. The survey was conducted among 137 customers of the selected brewery in Czestochowa. The average values of evaluations of all individual questions from both parts of survey were calculated. Then, average values for the pair of statements (performance; importance were placed in the importance-performance map. The analysis revealed that the service quality of the research brewery is placed in quadrant II, i.e. the area of reasonable property of needs. This means that the improvement of service quality is not necessary.

  6. Irradiation and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Bae, Ki Kwang; Yang, M. S.; Song, K. C.

    2000-05-01

    The objectives of the project is to establish the performance evaluation system for the experimental verification of DUPIC fuel. The scope and content for successful accomplishment of the phase 1 objectives is established as follows : irradiation test of DUPIC fuel at HANARO using a noninstrument capsule, study on the characteristics of DUPIC pellets, development of the analysis technology on the thermal behaviour of DUPIC fuel, basic design of a instrument capsule. The R and D results of the phase 1 are summarized as follows : - Performance analysis technology development of DUPIC fuel by model development for DUPIC fuel, review on the extendability of code(FEMAXI-IV, FRAPCON-3, ELESTRESS). - Study on physical properties of DUPIC fuel by design and fabrication of the equipment for measuring the thermal property. - HANARO irradiation test of simulated DUPIC fuel by the noninstrument capsule development. - PIE and result analysis

  7. Irradiation and performance evaluation of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ki Kwang; Yang, M S; Song, K C [and others

    2000-05-01

    The objectives of the project is to establish the performance evaluation system for the experimental verification of DUPIC fuel. The scope and content for successful accomplishment of the phase 1 objectives is established as follows : irradiation test of DUPIC fuel at HANARO using a noninstrument capsule, study on the characteristics of DUPIC pellets, development of the analysis technology on the thermal behaviour of DUPIC fuel, basic design of a instrument capsule. The R and D results of the phase 1 are summarized as follows : - Performance analysis technology development of DUPIC fuel by model development for DUPIC fuel, review on the extendability of code(FEMAXI-IV, FRAPCON-3, ELESTRESS). - Study on physical properties of DUPIC fuel by design and fabrication of the equipment for measuring the thermal property. - HANARO irradiation test of simulated DUPIC fuel by the noninstrument capsule development. - PIE and result analysis.

  8. Fiscal year 1998 Battelle performance evaluation agreement revision 1; TOPICAL

    International Nuclear Information System (INIS)

    DAVIS, T.L.

    1998-01-01

    Fiscal Year 1998 represents the second full year utilizing a results-oriented, performance-based contract. This document describes the critical outcomes, objectives, performance indicators, expected levels of performance, and the basis for the evaluation of the Contractors performance for the period October 1, 1997 through September 30, 1998, as required by Articles entitled Use of Objective Standards of Performance, Self Assessment and Performance Evaluation and Critical Outcomes Review of the Contract DE-AC08-76RLO1830. In partnership with the Contractor and other key customers, the Department of Energy (DOE) Richland Operations Office has defined six critical outcomes that same as the core for the Contractors performance evaluation. The Contractor also utilizes these outcomes as a basis for overall management of the Laboratory. As stated above six critical outcomes have been established for FY 1998. These outcomes are based on the following needs identified by DOE-HQ, RL and other customers of the Laboratory. Our Energy Research customer desires relevant, quality and cost effective science. Our Environmental Management customer wants technology developed, demonstrated, and deployed to solve environmental cleanup issues. To ensure the diversification and viability of the Laboratory as a National asset, RL and HQ alike want to increase the Science and Technical contributions of PNNL related to its core capabilities. RL wants improved leadership/management, cost-effective operations, and maintenance of a work environment, which fosters innovative thinking and high morale. RL and HQ alike desire compliance with environment, safety and health (ES and H) standards and disciplined conduct of operations for protection of the worker, environment, and the public, As with all of Hanford, DOE expects contribution of the Laboratory to the economic development of the Tri-Cities community, and the region, to build a new local economy that is less reliant on the Hanford mission

  9. A Step beyond Univision Evaluation: Using a Systems Model of Performance Improvement.

    Science.gov (United States)

    Sleezer, Catherine M.; Zhang, Jiping; Gradous, Deane B.; Maile, Craig

    1999-01-01

    Examines three views of performance improvement--scientific management, instructional design, and systems thinking--each providing a unique view of performance improvement and specific roles for evaluation. Provides an integrated definition of performance and a synthesis model that encompasses the three views. (AEF)

  10. Professional performance evaluation within the Romanian administrative system

    Directory of Open Access Journals (Sweden)

    Cristina MANOLE

    2010-12-01

    Full Text Available The current economic crisis, manifested in the entire world, highlights the need for sustained involvement of the local and regional authorities in each country, in conceiving and implementing Community policies (which already exist at European level having an essential role in implementing the economic plans achievement. This view was shared by all European Union Member States, of which Romania is part, since 2007. Therefore, the economic crisis which is reflected in the Romanian society today, requires prompt and sustained intervention by the authorities in the execution of the economic recovery plan, implying the community strategies, due to sharply budgetary expenses cut, which is found in all European countries. In order to achieve this major objective, the Romanian authorities should have qualified and properly motivated personnel through an adequate remuneration, according to the training, skills, responsibilities and especially individual performance obtained at each position, as it happens in most developed countries of the European Union. In this context, this study approaches the issues related to the performance evaluation of the public sector’s employees. Considering the fact that strengthening and developing the human resources segment is a strategic goal of the Romanian administration for the period 2008 - 2013, which will lead to modernizing it and making it more efficient (at both central and local level, the personnel performance evaluation, at the organizational level represents a fundamental activity from the human resources’ management perspective.

  11. Evaluation of linear accelerator performance standards using an outcome oriented approach

    International Nuclear Information System (INIS)

    Rangel, Alejandra; Ploquin, Nicolas; Kay, Ian; Dunscombe, Peter

    2008-01-01

    Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest

  12. 29 CFR 1960.11 - Evaluation of occupational safety and health performance.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Evaluation of occupational safety and health performance. 1960.11 Section 1960.11 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... AND HEALTH PROGRAMS AND RELATED MATTERS Administration § 1960.11 Evaluation of occupational safety and...

  13. General Video Game Evaluation Using Relative Algorithm Performance Profiles

    DEFF Research Database (Denmark)

    Nielsen, Thorbjørn; Barros, Gabriella; Togelius, Julian

    2015-01-01

    In order to generate complete games through evolution we need generic and reliably evaluation functions for games. It has been suggested that game quality could be characterised through playing a game with different controllers and comparing their performance. This paper explores that idea throug...

  14. Evaluation of Growth Performance of Tomato in Response to ...

    African Journals Online (AJOL)

    Sunusi

    ABSTRACT. Field experiment was conducted in 2013 and 2014 to evaluate growth performance of two tomato genotypes in response to biochar application and arbuscular mycorrhizal fungal (AMF) inoculation at the. Teaching and Research Farm, Federal University of Agriculture, Abeokuta. The experiment was laid out.

  15. A study on the performance evaluation of small gamma camera collimators using detective quantun efficiency

    International Nuclear Information System (INIS)

    Jeon, Ho Sang

    2008-02-01

    The anger-type gamma camera and novel marker compound using Tc-99m were firstly introduced in 1963. The gamma camera systems have being improved and applied to various fields, for example, medical, industrial, and environmental fields. Gamma camera is mainly composed of collimator, detector, and signal processor. And the radiative source is namely the imaging object. The collimator is essential component of gamma camera system because the imaging performance of system is mainly dependent on the collimator. The performance evaluation of collimators can be done by using evaluating factors. In this study, the novel factors for gamma camera evaluation are suggested. The established evaluating factors by NEMA are FWHM, sensitivity, and uniformity. They have some limitations in spite of their usefulness. Firstly, performance evaluation by those factors give insensitive and indirect results only. Secondly, the evaluation of noise property is ambiguous. Thirdly, there is no synthetic evaluation of system performance. Simulation with Monte Carlo code and experiment with a small camera camera were simultaenuously performed to verify novel evaluating factors. For the evaluation of spatial resolution, MTF was applied instead of FWHM. The MTF values presents excellent linear relationship with FWHM values. The NNPS was applied instead of uniformity and sensitivity for the evaluation of noise fluctuation. The NNPS values also presents linear relationship with sensitivity and unifomity. Moreover, these novel factors give quantities as the function of spatial frequencies. Finally, the DQE values were given by calculations with MTF, NNPS, and input SNR. DQE effectively presents the synthetic evaluation of gamma camera performance. It is the conclusion that MTF, NNPS, and DQE can be novel evaluating factors for gamma camera systems and the new factor for synthetic evaluation is derived

  16. The Evaluation of Higher Education Expenditure Performance and Investment Mechanism Reform

    Science.gov (United States)

    Wang, De; Fu, Meiying

    2009-01-01

    Along with the reform of Chinese Government public finance, higher education belongs to the public product, gradually changes from "fund investment management" to the "expenditure performance management". The evaluation of expenditure performance system becomes the key point of higher education investment mechanism reform. This…

  17. Dual throat NaK pump performance evaluation (conceptual design of prototype)

    International Nuclear Information System (INIS)

    Johnson, J.L.

    1972-01-01

    An evaluation of the performance of the dual throat NaK pump for the 5 Kwe Reactor TE System is discussed. Performance at nominal operating conditions and at startup conditions is predicted. The basis for selection of this pump design is presented. (U.S.)

  18. Performance evaluation of Siemens E.Cam® Spect System at Korle ...

    African Journals Online (AJOL)

    Performance evaluation of Siemens E.Cam® Spect System at Korle-Bu Teaching Hospital (Ghana. ... The tests were performed according to National Electrical Manufac-turers Association protocols, and different measuring instruments and phantoms containing 99m-Tc were used. Extrinsic uniformity, System energy ...

  19. A model of R-D performance evaluation for Rate-Distortion-Complexity evaluation of H.264 video coding

    DEFF Research Database (Denmark)

    Wu, Mo; Forchhammer, Søren

    2007-01-01

    This paper considers a method for evaluation of Rate-Distortion-Complexity (R-D-C) performance of video coding. A statistical model of the transformed coefficients is used to estimate the Rate-Distortion (R-D) performance. A model frame work for rate, distortion and slope of the R-D curve for inter...... and intra frame is presented. Assumptions are given for analyzing an R-D model for fast R-D-C evaluation. The theoretical expressions are combined with H.264 video coding, and confirmed by experimental results. The complexity frame work is applied to the integer motion estimation....

  20. State of the art of durability-performance evaluation of hardened cement based on phase compositions

    International Nuclear Information System (INIS)

    Kurashige, Isao; Imoto, Harutake; Yamamoto, Takeshi; Hironaga, Michihiko

    2006-01-01

    Upgrading durability-performance evaluation technique for concrete is urgently demanded in connection to its application to radio-active waste repository which needs ultra long-term durability. Common concrete structures also require an advanced method for minimizing the life-cycle cost. The purpose of this research is to investigate current problems and future tasks on durability-performance evaluation of hardened cement from the view point of phase composition. Although the phase composition of hardened cement has not fully been reflected to durability-performance evaluation, it influences concrete durability as well as its pore structure. This report reviews state of the art of the factors affecting phase composition, analytical and experimental evaluation techniques for phase composition, and durability-performance evaluation methods of hardened cement based on phase composition. (author)