WorldWideScience

Sample records for multielemental activation analysis

  1. Multielemental neutron activation analysis of some egyptian cement samples

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Abdel-Basset, N.; Soroor, A.; Hassan, A.M.

    1996-01-01

    Multielemental analysis of normal, Karnak and sea-water cement samples were performed by neutron activation analysis technique using the (ET-R R-1) reactor for sample irradiation. The Data were collected and analysed by means of the (HPGe) detection system and a Pca computer. A total of 23 elements namely, Na, A1, C 1, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Sr, Ba, La, Sm, Eu, Yb, Lu, Ta, Au, Th and U were identified and analysed with concentrations ranging from 1 ppm upto 62% a comparison between the elemental concentrations of the three cement types is given. 2 tabs

  2. Multielemental analysis of milk samples

    International Nuclear Information System (INIS)

    Omar Al-Dayel; Jameel Al-Hefne; Didarul A Chowdhury; Turki Al-Ajyan

    2002-01-01

    Milk is a basic food since it provides essential nutrients (proteins, lipids, carbohydrates) and micronutrients (minerals, Vitamins, enzymes). In fact, in formula milk essential elements have been usually added in order to satisfy nutritional requirements. However, too high additions of these elements can produce detrimental effects on human health. More important, milk can also constitute a source of exposure to toxic elements, especially dangerous for infants. Method is presented for the multielemental analysis of a wide range of elements in milk samples. The aim of this work is the development of a multielemental method for the analysis of major, minor and trace essential and toxic elements in milk. Several milk samples with different origins were collected from the Saudi Arabia markets and analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS). For preparation of the samples for analysis, they were digested by closed vessel microwave digestion system with H 2 O 2 /HNO 3 . About 40 elements were determined. A reference material was analysed for the validation of the proposed method. (Author)

  3. Multielemental speciation analysis by advanced hyphenated technique - HPLC/ICP-MS: A review.

    Science.gov (United States)

    Marcinkowska, Monika; Barałkiewicz, Danuta

    2016-12-01

    Speciation analysis has become an invaluable tool in human health risk assessment, environmental monitoring or food quality control. Another step is to develop reliable multielemental speciation methodologies, to reduce costs, waste and time needed for the analysis. Separation and detection of species of several elements in a single analytical run can be accomplished by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Our review assembles articles concerning multielemental speciation determination of: As, Se, Cr, Sb, I, Br, Pb, Hg, V, Mo, Te, Tl, Cd and W in environmental, biological, food and clinical samples analyzed with HPLC/ICP-MS. It addresses the procedures in terms of following issues: sample collection and pretreatment, selection of optimal conditions for elements species separation by HPLC and determination using ICP-MS as well as metrological approach. The presented work is the first review article concerning multielemental speciation analysis by advanced hyphenated technique HPLC/ICP-MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Reactor neutron activation for multielemental analysis

    International Nuclear Information System (INIS)

    Reddy, A.V.R.

    1999-01-01

    Neutron Activation Analysis using single comparator (K 0 NAA method) has been used for obtaining multielemental profiles in a variety of matrices related to environment. Gold was used as the comparator. Neutron flux was characterised by determining f, the epithermal to thermal neutron flux ratio and cc, the deviation from ideal shape of the neutron spectrum. The f and a were determined in different irradiation positions in APSARA reactor, PCF position in CIRUS reactor and tray rod position in Dhruva reactor using both cadmium cut off and multi isotope detector methods. High resolution gamma ray spectrometry was used for radioactive assay of the activation products. This technique is being used for multielement analysis in a variety of matrices like lake sediments, sea nodules and crusts, minerals, leaves, cereals, pulses, leaves, water and soil. Elemental profiles of the sediments corresponding to different depths from Nainital lake were determined and used to understand the history of natural absorption/desorption pattern of the previous 160 years. Ferromanganese crusts from different locations of Indian Ocean were analysed with a view to studying the distribution of some trace elements along with Fe and Mn. Variation of Mn/Fe ratio was used to identify the nature of the crusts as hydrogenous or hydrothermal. Fe-rich and Fe-depleted nodules from Indian Ocean were analysed to understand the REE patterns and it is proposed that REE-Th associated minerals could be the potential Th contributors to the sea water and thus reached ferromanganese nodules. Dolomites (unaltered and altered), two types of serpentines and intrusive rock dolerite from the asbestos mines of Cuddapah basin were analysed for major, minor and trace elements. The elemental concentrations are used for distinguishing and characterising these minerals. From our investigations, it was concluded that both dolomite and dolerite contribute elements in the serpentinisation process. Chemical neutron

  5. Multielemental analysis of surface sediments in Havana bay (Cuba) using X-ray fluorescence

    International Nuclear Information System (INIS)

    Gelen, A.; Corrales, Y.; Lopez, N.; Manso Guevara, M. V.; Casanova, A. O.; Alessandro, K. D'; Diaz, O.; Espen, P. Van; Beltran, J.; Soto, J.

    2006-01-01

    Multielemental Analysis was performed in Superficial Sediments in Havana Bay. Twenty one samples were analysed by Dispersive Energy X- Ray Fluorescence using an spectrometer based on Si (Li) semiconductor detector an a 109 Cd source. The results showed a similar behaviour in the levels of contamination related with neutron activation analysis. The data suggest that an anthropogenic input into the bay from domestic sewage and industries occurred. (Full text)

  6. Multi-elemental profile of some Brazilian make-up products by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dalmazio, Ilza; Menezes, Maria Angela de B.C., E-mail: id@cdtn.b, E-mail: menezes@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas. Lab. de Ativacao Neutronica

    2011-07-01

    Recent works have shown that analysis in cosmetics and beauty products from the European and Asian markets indicate the presence of U, Th and rare earths besides other trace elements. Considering these previous findings and health issues, it would be valuable to obtain information on elements in cosmetics available in the Brazilian market. The purpose of this study was to acquire a multi-elemental profile of some Brazilian make-up products of diverse brands. Samples of eye shadow, liquid base, facial concealer, lipstick, and compact face powder were analyzed applying neutron activation analysis, k{sub 0}-standardization method at CDTN/CNEN, using the TRIGA Mark I IPR-R1 research reactor. Concentrations of more than 30 elements in samples are presented and it was found elements included in Brazilian National Health Surveillance Agency prohibitive list, rare earths, Th and U in a minimum of two cosmetic samples. (author)

  7. Multi-elemental profile of some Brazilian make-up products by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Dalmazio, Ilza; Menezes, Maria Angela de B.C.

    2011-01-01

    Recent works have shown that analysis in cosmetics and beauty products from the European and Asian markets indicate the presence of U, Th and rare earths besides other trace elements. Considering these previous findings and health issues, it would be valuable to obtain information on elements in cosmetics available in the Brazilian market. The purpose of this study was to acquire a multi-elemental profile of some Brazilian make-up products of diverse brands. Samples of eye shadow, liquid base, facial concealer, lipstick, and compact face powder were analyzed applying neutron activation analysis, k 0 -standardization method at CDTN/CNEN, using the TRIGA Mark I IPR-R1 research reactor. Concentrations of more than 30 elements in samples are presented and it was found elements included in Brazilian National Health Surveillance Agency prohibitive list, rare earths, Th and U in a minimum of two cosmetic samples. (author)

  8. The application of x-ray fluorescence spectrometry for multielemental analysis of air particulate samples

    International Nuclear Information System (INIS)

    Mohamad Rashid Mohamad Yusoff

    1986-01-01

    The performance of XRF spectrometer as a tool for multielemental analysis of air pollution samples was discussed. The non-destructive couples with multielemental nature of the technique satisfactory sensitivity for most elements were the most important characteristics for its popularity as a method of analysis. Thus, the technique promises a significant reduction in cost and time of analysis. As a result, more extensive and revealing air particulates survey should be possible, with consequent improvements in the discovery and positive identification of particulate pollution sources. (author)

  9. Bear diet, seasonality and migration based on chemical multielemental teeth analysis

    Czech Academy of Sciences Publication Activity Database

    Nývltová Fišáková, Miriam; Galiová, M.; Kaiser, J.; Fortes, F. J.; Novotný, K.; Malina, R.; Prokeš, L.; Hrdlička, A.; Vaculovič, T.; Laserna, J. L.

    2009-01-01

    Roč. 50, 1-2 (2009), s. 27-34 ISSN 1211-7250 R&D Projects: GA AV ČR KJB800010701 Institutional research plan: CEZ:AV0Z80010507 Keywords : Mammalia * Upper Palaeolithic * Migration * Diet * Seasonality * Multielemental analysis * LIBS * LA-ICP-MS Subject RIV: AC - Archeology, Anthropology, Ethnology

  10. Multielemental analysis in small amounts of environmental reference materials with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Dombovári, J; Becker, J S; Dietze, H J

    2000-07-01

    The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95-110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02-0.38 microg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 microg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5-10 microg/L) to test the analytical method and the recoveries were 95-105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1-5 mg) for method development and quality control.

  11. Multielemental X-ray radiometric analysis of ferromanganese concretions

    International Nuclear Information System (INIS)

    Metelev, A.Yu.; Grigor'ev, A.I.; Rakita, K.A.; Mamaenko, M.V.; Ivanenko, V.V.

    1994-01-01

    Ferromanganese concretions are promising mineral resources of the ocean. Most often, they are analyzed by atomic-absorption, spectra, X-ray spectral, neutron-activation, and X-ray radiometric methods. Note that X-ray radiometric analysis (XRRA) allows the sufficiently rapid determination of a great number of elements in ferromanganese concretions. The possibility of using XRRA with saturated and thin layers was shown; however, the data on the precision and accuracy of the technique was not given. The purpose of this study is to evaluate the basic performance characteristics of the multielemental X-ray radiometric analysis of ferromanganese concretions (Pacific Ocean). Determinations for K,Ca and Ti content were made using a 55 Fe source and for Mn, Fe, Ni, Cu, Zn, Pb, Sr, Y, Zr, Nb, and Mo contents by using a 109 Cd source. The precision and accuracy of the method was investigated by using reference concretions; it was found the confidence intervals overlap for all of the elements except Ca and Pb. The relative standard deviation was 1-5%, indicating the high precision of the method. The described technique is successfully used on research vessels of the Far East Division of the Russian Academy of Sciences and in South Pacific Ocean geological expeditions of PO open-quotes Dal'morgeologiyaclose quotes

  12. Activation analysis of coal with the help of a microtron

    International Nuclear Information System (INIS)

    Sodnom, N.; Gehrbish, Sh.

    1989-01-01

    Activation analysis techniques using microtron bremsstrahlung and photoneutrons have been developed for the multielemental analysis of coal. Analysis data for coals from 17 mines of Mongolia are presented. The chlorine content of coal and the distribution of elements in coal burning products are determined. Control experiments were performed at the reactors IBR-2 and ARGUS. The results of the gamma activation analysis are compared with neutron activation and X-ray fluorescence analyses data. It is shown that the microtron irradiation techniques employed provide a satisfactory multielemental basis for the analysis of coal. (author)

  13. Simultaneous and multielemental analysis by muonic x-rays for inside Japanese bronze and gold coins

    International Nuclear Information System (INIS)

    Ninomiya, K.; Yoshida, G.; Inagaki, M.; Shinohara, A.; Kubo, M.K.; Suzuki, T.; Nagatomo, T.; Kawamura, N.; Strasser, P.; Shimomura, K.; Miyake, Y.; Kobayashi, Y.; Higemoto, Wataru; Sakamoto, Shinichi; Saito, T.

    2013-01-01

    A nondestructive, quantitative and multielemental analysis method for bulk samples was develop, which was based on the measurement of high-energy muonic X-rays emitted from muonic atoms inside material after muon irradiation. We demonstrated quantitative determination of the elemental composition inside archaeological artifacts without sample destruction. (author)

  14. Multi-element analysis of wheat flour and white bread by neutron activation.; Analisis multielemental en harina de trigo y pan blanco por activacion neutronica.

    Energy Technology Data Exchange (ETDEWEB)

    Godinez A, M A

    1994-12-31

    One of the best source of feeding even for the human being as for animals are the Cereals. Although they are mainly energetic aliment, due to its composition in starch, they are a very important source of proteins and amino acids. They contribute mineral elements to the diet. Even those elements constitute a very small part of the total diet, they take a very important place in many human metabolic processes. To make a multielemental analysis of an aliment is very important that we are based on a very sensible analytic technique so we are able to find them, just as the Neutronic Activation. This Nuclear technique allows you to make a qualitative and quantitative analysis of the elements that are in a sample, but it does n`t show the way in which the elements are presented. It is based in turning those elements into radioactive ones through its exposition to an uniform and constant fluid of neutrons, so then its radioactivity can be determined. The present work has as a main purpose to make a multielemental analysis of the wheat flour and white bread through the Neutronic Activation Technique, using the comparator method and establishing previously the most appropriate work conditions as much irradiation as digestion and measuring of the radioactivity of the sample. In this way, it was able to know that the wheat flour has potassium, chlorine, magnesium, sodium, iron, zinc, manganese, rubidium and selenium elements in a concentration of 2000, 700, 500, 25, 18, 13, 5.5, 0.9 and 0.01 - 0.3 mg/g respectively. In an other hand it was found that the white bread has the same elements than the wheat flour but its concentration was: 1700, 9000, 400, 7000, 52, 13, 6, 1 and 0.05 - 0.3 mg/g respectively. (Author).

  15. Preconcentration NAA for simultaneous multielemental determination in water sample

    International Nuclear Information System (INIS)

    Chatt, A.

    1999-01-01

    Full text: Environment concerns with water, air, land and their interrelationship viz., human beings, fauna and flora. One of the important environmental compartments is water. Elements present in water might face a whole lot of physico-chemical conditions. This poses challenges to measure their total concentrations as well as different species. Preconcentration of the elements present in water samples is a necessary requisites in water analysis. For multi elements concentration measurements, Neutron Activation Analysis (NAA) is one of the preferred analytical techniques due to its sensitivity and selectivity. In this talk preconcentration NAA for multielemental determination in water sample determination will be discussed

  16. Applicability of PIXE for multielemental analysis in a biomedical application

    International Nuclear Information System (INIS)

    Shakir, N.S.

    1987-07-01

    The applicability of PIXE for multielemental analysis is demonstrated. The method is used in a major systematic study on hair samples using one target analysis. The pathological state considered is agitated elderly people. The main elements examined are S, K, Ca, Fe, Co, Ni, Cu, Zn, Se, Br, Hg and Pb. The minimum detectable limits are 1-10 ppm using 180 μg of dry hair at 25 μe irradiations for elements between K and Br. The significance of differences between the hair elements in control populations and patients suffering from the pathological conditions are investigated. Investigations of possible linear and multiple-correlations between elements in each population are made. The work indicates that some elements do exhibit variation with pathological state, and the multielement PIXE analysis gives useful information about the subject. (author). 13 refs, 4 figs, 6 tabs

  17. Evaluation of pressed powders and thin section standards for multi-elemental analysis by conventional and micro-PIXE analysis

    International Nuclear Information System (INIS)

    Homma-Takeda, Shino; Iso, Hiroyuki; Ito, Masaki

    2010-01-01

    For multi-elemental analysis, various standards are used to quantify the elements consists of environmental and biological samples. In this paper two different configuration standards, pressed powders and thin section standards, were assessed for their purpose as standards by conventional and micro-PIXE analysis. Homogeneity of manganese, iron, zinc (Zn), copper and yttrium added to pressed powder standard materials were validated and the relative standard deviation (RSD) of the X-ray intensity of the standards was 2 area and the metal concentration was acceptable. (author)

  18. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    2000-01-01

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  19. Digital TV-echelle spectrograph for simultaneous multielemental analysis using microcomputer control

    International Nuclear Information System (INIS)

    Davidson, J.B.; Case, A.L.

    1980-12-01

    A digital TV-echelle spectrograph with microcomputer control was developed for simultaneous multielemental analysis. The optical system is a commercially available unit originally equipped for film and photomultiplier (single element) readout. The film port was adapted for the intensifier camera. The camera output is digitized and stored in a microcomputer-controlled, 512 x 512 x 12 bit memory and image processor. Multiple spectra over the range of 200 to 800 nm are recorded in a single exposure. Spectra lasting from nanoseconds to seconds are digitized and stored in 0.033 s and displayed on a TV monitor. An inexpensive microcomputer controls the exposure, reads and displays the intensity of predetermined spectral lines, and calculates wavelengths of unknown lines. The digital addresses of unknown lines are determined by superimposing a cursor on the TV display. The microcomputer also writes into memory wavelength fiducial marks for alignment of the TV camera

  20. Multielemental analysis of ferromanganese nodules from Central Indian Ocean Basin by PIXE

    International Nuclear Information System (INIS)

    Dutta, R. K.; Vijayan, V.; Ghosh, S.; Chakravortty, V.

    1997-01-01

    Ferromanganese nodules found on the Ocean bed are complex heterogeneous mixtures of several components. Two nodules from Central Indian Ocean Basin (CIOB) were analysed by proton induced X-ray emission (PIXE) technique using 3UD Tandem pelletron. The precision and the accuracy of this technique for chemical analyses has been confirmed by analysing USGS Geological Standards. Thick sample targets were bombarded by 3 MeV protons for the multielemental analysis. GUPIX-96 software was used for spectral data analysis. Quantitative estimate of K, Ca, Tl, V, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Rb, Sr, Y, Zr, Mo, Ba, Ce, Tl and Pb has been ascertained. The occurrence of Ga, Ge, Rb and Zr in nodules from this region is reported for the first time. The role of manganese and iron oxide phases in determining the uptake of various trace elements from ocean water and bottom sediment pore water has been discussed. (author)

  1. Micro-scaled high-throughput digestion of plant tissue samples for multi-elemental analysis

    Directory of Open Access Journals (Sweden)

    Husted Søren

    2009-09-01

    Full Text Available Abstract Background Quantitative multi-elemental analysis by inductively coupled plasma (ICP spectrometry depends on a complete digestion of solid samples. However, fast and thorough sample digestion is a challenging analytical task which constitutes a bottleneck in modern multi-elemental analysis. Additional obstacles may be that sample quantities are limited and elemental concentrations low. In such cases, digestion in small volumes with minimum dilution and contamination is required in order to obtain high accuracy data. Results We have developed a micro-scaled microwave digestion procedure and optimized it for accurate elemental profiling of plant materials (1-20 mg dry weight. A commercially available 64-position rotor with 5 ml disposable glass vials, originally designed for microwave-based parallel organic synthesis, was used as a platform for the digestion. The novel micro-scaled method was successfully validated by the use of various certified reference materials (CRM with matrices rich in starch, lipid or protein. When the micro-scaled digestion procedure was applied on single rice grains or small batches of Arabidopsis seeds (1 mg, corresponding to approximately 50 seeds, the obtained elemental profiles closely matched those obtained by conventional analysis using digestion in large volume vessels. Accumulated elemental contents derived from separate analyses of rice grain fractions (aleurone, embryo and endosperm closely matched the total content obtained by analysis of the whole rice grain. Conclusion A high-throughput micro-scaled method has been developed which enables digestion of small quantities of plant samples for subsequent elemental profiling by ICP-spectrometry. The method constitutes a valuable tool for screening of mutants and transformants. In addition, the method facilitates studies of the distribution of essential trace elements between and within plant organs which is relevant for, e.g., breeding programmes aiming at

  2. Multielemental characterization of sediments from rivers and reservoirs of a sediment quality monitoring network of Sao Paulo state, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Walace A.A.; Quinaglia, Gilson A., E-mail: wasoares@sp.gov.br, E-mail: gquinaglia@sp.gov.br [Companhia Ambiental do Estado de Sao Paulo (CETESB), SP (Brazil). Setor de Analises Toxicologicas; Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (LAN/CRPq/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2013-07-01

    The Environment Company of the State of Sao Paulo (CETESB) by means of its quality monitoring network does, systematically, the assessment of water and sediment quality in rivers and reservoirs in the Sao Paulo state. The quality evaluation is done by means 50 parameters in water and 63 for sediment that are considered the more representative for CETESB monitoring. In 2011 the network monitoring analyzed 420 points being 24 in sediments. In the present study the multielemental characterization (total concentration) of 13 sediment samples from 24 rivers and reservoirs belonging to the CETESB monitoring network were analyzed by instrumental neutron activation analysis (INAA). The analytical validation according to precision and accuracy was checked through certified reference materials analyzes BEN (Basalt-IWG-GIT), SL-1 (Lake Sediment - IAEA) and Soil-5 (IAEA), that presents certified concentration values for all elements analyzed. The results obtained for multielemental characterization were compared to NASC values (North American Shale Composite) and the enrichment factor (EF) by using Sc as a normalizer element was calculated. The results showed higher enrichment values for As, Br, Cr, Hf, Ta, Th , U and Zn and rare earth elements (REE) Ce, Eu, La, Nd, Sm, Tb and Yb in many of the tested sediment samples indicating that there may be an anthropogenic contribution for these elements. The multielemental results were also compared to the granulometric composition of the sediment samples. Factorial and Cluster Analysis were applied and indicated that the elements distribution is controlled, mainly by the granulometric fractions of the sediments. (author)

  3. Multielemental characterization of sediments from rivers and reservoirs of a sediment quality monitoring network of Sao Paulo state, Brazil

    International Nuclear Information System (INIS)

    Soares, Walace A.A.; Quinaglia, Gilson A.; Favaro, Deborah I.T.

    2013-01-01

    The Environment Company of the State of Sao Paulo (CETESB) by means of its quality monitoring network does, systematically, the assessment of water and sediment quality in rivers and reservoirs in the Sao Paulo state. The quality evaluation is done by means 50 parameters in water and 63 for sediment that are considered the more representative for CETESB monitoring. In 2011 the network monitoring analyzed 420 points being 24 in sediments. In the present study the multielemental characterization (total concentration) of 13 sediment samples from 24 rivers and reservoirs belonging to the CETESB monitoring network were analyzed by instrumental neutron activation analysis (INAA). The analytical validation according to precision and accuracy was checked through certified reference materials analyzes BEN (Basalt-IWG-GIT), SL-1 (Lake Sediment - IAEA) and Soil-5 (IAEA), that presents certified concentration values for all elements analyzed. The results obtained for multielemental characterization were compared to NASC values (North American Shale Composite) and the enrichment factor (EF) by using Sc as a normalizer element was calculated. The results showed higher enrichment values for As, Br, Cr, Hf, Ta, Th , U and Zn and rare earth elements (REE) Ce, Eu, La, Nd, Sm, Tb and Yb in many of the tested sediment samples indicating that there may be an anthropogenic contribution for these elements. The multielemental results were also compared to the granulometric composition of the sediment samples. Factorial and Cluster Analysis were applied and indicated that the elements distribution is controlled, mainly by the granulometric fractions of the sediments. (author)

  4. Activation analysis in food analysis. Pt. 9

    International Nuclear Information System (INIS)

    Szabo, S.A.

    1992-01-01

    An overview is presented on the application of activation analysis (AA) techniques for food analysis, as reflected at a recent international conference titled Activation Analysis and its Applications. The most popular analytical techniques include instrumental neutron AA, (INAA or NAA), radiochemical NAA (RNAA), X-ray fluorescence analysis and mass spectrometry. Data are presented for the multielemental NAA of instant soups, for elemental composition of drinking water in Iraq, for Na, K, Mn contents of various Indian rices, for As, Hg, Sb and Se determination in various seafoods, for daily microelement takeup in China, for the elemental composition of Chinese teas. Expected development trends in AA are outlined. (R.P.) 24 refs.; 8 tabs

  5. Applications of neutron activation analysis in environmental science, biology and geoscience

    International Nuclear Information System (INIS)

    1992-01-01

    The applications of neutron activation analysis technique with high sensitivity, good accuracy, multielemental analysis and non-destruction of samples in hydrosphere, soil and lithosphere, atmosphere, cosmosphere and biosphere were introduced in this book. A large amount of research activities in this field during the 20 years and more carried out by Neutron Activation Analysis Laboratory, Institute of High Energy Physics, Academia Sinica, was summarized. A number of the data and information with important scientific significance was provided

  6. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    Science.gov (United States)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  7. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Peña, M., E-mail: mlpena@sgc.gov.co; Sierra, O., E-mail: osierra@sgc.gov.co; Porras, A.; Alonso, D.; Herrera, D. C., E-mail: dherrera@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  8. Rapid methods for multi-elemental X-ray fluorescence analysis using excitation isotope sources and Si(Li)-semiconductor detector

    International Nuclear Information System (INIS)

    Zhuravleva, E.L.

    1980-01-01

    Some rapid methods using an unique calibration curve have been developed for multi-elemental X-ray fluorescence analysis of thin and thick layers of various samples having low contents of heavy elements. The matrix absorption effect in thick samples is taken into account according to the scattered radiation.The similar method using a unique calibration curve for determination of low contents of trace elements in thin layers without account of matrix effect is proposed. The results on the intercomposition run soil-5 are in good agreement with the data obtained in different laboratories. The errors of the method are 10 %; in a case of peak superposition - 15 %

  9. Neutron activation analysis in minerals prospecting

    International Nuclear Information System (INIS)

    Gomez, H.; Duque O, J.

    1988-01-01

    One method multielemental analysis in geological samples has been developed by neutron activation analysis without using standards and by eliminating many of the error sources of the absolute method. It uses the ratio of the activities induced by mass unit, between the element in the sample and one cobalt monitor. The detection limits are good for more than thirty elements in many prospecting programs, with a standard deviation less than 7%. The neutron flux used is 2x10 11 nxcm -2 .S -1 and the HPGE detector has a relative efficiency of 20% and an energy resolution of 1.9 KeV in 1332 KeV photopeak

  10. Application of neuro-fuzzy model for neutron activation analysis (NAA)

    International Nuclear Information System (INIS)

    Khalafi, H.; Terman, M.S.; Rahmani, F.

    2011-01-01

    Neutron activation analysis (NAA) is a precise chemical multielemental method of analysis which is satisfactorily used for qualitative and quantitative analyses. Repeated irradiation is needed because of mal-determination of some elements due to peak overlap in qualitative analysis. In this study, NAA procedure has been modified using a neuro-fuzzy model to avoid repeated irradiation based on multilayer perceptrons network trained by the Levenberg Marquardt algorithm. This method increases the precision of spectrum analysis in the case of strong background and peak overlap. (authors)

  11. Provenience studies of the Ko-Kutani ware by neutron activation analysis

    International Nuclear Information System (INIS)

    Kawashima, Tatsuro.

    1990-01-01

    The instrumental neutron activation analysis has been applied to the multielemental analysis of eight samples of the Ko-Kutani ware including the Aote's that is one of semi-porcelain body. Each sample was compared with concentration of the useful index element, such as Ta, Sc, Ba, Hf, Th and rare earth, to discriminate the Arita group from the Kutani group. Eight samples were judged as products of the Arita, just as in previous paper. (author)

  12. Determination of rare earth elements in sea sediments from the Cuban northwestern coast by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Pena Fortes, B.; Diaz Riso, O.; Hernandez Rivero, A.T.

    1998-01-01

    The multielemental characterization of sea sediments from an important Cuban coast was performed using instrumental Neutron activation analysis. The obtained results shown an impoverishment of in the studied zone, in comparison with the data taken from other Cuban coaster zones

  13. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  14. Neutron-activation analysis of wall soils of ancient architectural monuments

    International Nuclear Information System (INIS)

    Khatamov, Sh.; Zhumamuratov, A.; Ibragimov, T.; Tillyaev, T.; Osinskaya, N.S.; Rakhmanova, T.P.; Pulatov, D.D.

    2001-01-01

    The simplified, relatively inexpensive, and productive multielemental neutron activation techniques for analysis of solid of the architectural monuments of Karakalpakstan have been elaborated. A comparison of the elemental composition of the wall soils of the ancient buildings, constructed at different historical periods, with the composition of the agricultural soils allows us to estimate the present ecological and agrogeochemical states of the agricultural soils and to trace changing the dynamics of about 30 chemical elements. (author)

  15. Activation analysis and dendrochronology for estimating pollution histories

    International Nuclear Information System (INIS)

    Pillay, K.K.

    1976-01-01

    Neutron activation analysis of wood shavings from tree rings have shown that plant tissues grown through periods of varying environmental conditions keep permanent records of the trace elements they received though nutrients from their immediate surroundings. Detailed examination of several species of trees, along with dendrochronological data, suggest the possibilities of utilizing this technique for pollution monitoring as well as for developing valuable information for environmental modelling. The multielemental analyses of tree ring samples were done using multiple neutron irradiation and gamma-ray spectrometry using a high resolution Ge(Li) detector and a software orinted programmable multichannel analyzer. The neutron activation analysis consisted of two reactor irradiations and at least three countings at different decay periods. (T.G.)

  16. Practical considerations in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, N.

    2001-01-01

    Activation analysis is a technique of elemental analysis based on the measurement of characteristics radiation from radionuclides formed directly or indirectly by activation. The activation can be induced by bombarding the material with neutrons or charged particles or gamma rays. This is a well-accepted analytical technique for the determination of composition of complex materials. This technique is also sensitive at trace levels and is almost free from analytical interferences of matrix. It is used for multi-elemental determination in rocks, minerals, alloys, biological materials, geological samples, non-destructive analysis of materials and environmental samples such as water, air particulate matter, plants, soil, sediments and diets. This method is also used for production and measurements of radioisotopes in materials of known composition, for example, when radioactivation is used for nuclear reaction studies, for flux and beam intensity measurements for trace experiments and process quality control. In this article the parameters affecting the sensitivity of instrumental neutron activation analysis are briefly discussed. (author)

  17. Recent applications of neutron activation analysis in geoscience at Lucas Heights

    International Nuclear Information System (INIS)

    Fardy, J.J.

    1985-01-01

    In spite of developments in instrumental techniques of analysis over the last decade, neutron activation analysis has maintained its importance as a multielemental technique for analysing a wide range of geological materials. Some of its applications in geoscience at Lucas Heights over the last two years are discussed. These include hydrogeochemical and geological prospecting for gold in geothermal and bore water systems and ores, rare earth characterisation of shoshonitic lavas, altered basalts and dacites, and trace element studies of Australian oil shales and coals

  18. Multielemental determination in ten maize plant fragment using neutron activation analysis

    International Nuclear Information System (INIS)

    Spiridon, S.

    1993-01-01

    An instrumental activation technique has been developed for simultaneous analysis in dry ash maize plant samples of 18 elements: Al, Au, Ca, Ce, Co, Cr, Cs, Eu, Fe, La, Lu, K, Mg, Mn, Na, Rb, Sc, and Zn. Ten fragments of maize plants (dry ash) were analysed: leaves sheaths, beads, stumps, peduncles, spikes, unfruitfuls, interknots, knots, and corn husks, with a content distribution of the elements from percent to ppm. A precision of 5-7 % has been achieved on the basis of replicate analysis. The method is relatively simple and suitable for the analysis of biological samples. (Author)

  19. Optimization and development of the instrumental parameters for a method of multielemental analysis through atomic spectroscopy emission, for the determination of My, Fe Mn and Cr

    International Nuclear Information System (INIS)

    Lanzoni Vindas, E.

    1998-01-01

    This study optimized the instrumental parameters of a method of multielemental (sequential) analysis, through atomic emission, for the determination of My, Fe,Mn and Cr. It used the factorial design at two levels and the method of Simplex optimization, that permitted the determination of the four cations under the same instrumental conditions. The author studied an analytic system, in which the conditions were not lineal between instrumental answers and the concentration, having to make adjustment of the calibration curves in homocedastic and heterocedastic conditions. (S. Grainger)

  20. Neutron activation analysis of geochemical samples

    International Nuclear Information System (INIS)

    Rosenberg, R.; Zilliacus, R.; Kaistila, M.

    1983-06-01

    The present paper will describe the work done at the Technical Research Centre of Finland in developing methods for the large-scale activation analysis of samples for the geochemical prospecting of metals. The geochemical prospecting for uranium started in Finland in 1974 and consequently a manually operated device for the delayed neutron activation analysis of uranium was taken into use. During 1974 9000 samples were analyzed. The small capacity of the analyzer made it necessary to develop a completely automated analyzer which was taken into use in August 1975. Since then 20000-30000 samples have been analyzed annually the annual capacity being about 60000 samples when running seven hours per day. Multielemental instrumental neutron activation analysis is used for the analysis of more than 40 elements. Using instrumental epithermal neutron activation analysis 25-27 elements can be analyzed using one irradiation and 20 min measurement. During 1982 12000 samples were analyzed for mining companies and Geological Survey of Finland. The capacity is 600 samples per week. Besides these two analytical methods the analysis of lanthanoids is an important part of the work. 11 lanthanoids have been analyzed using instrumental neutron activation analysis. Radiochemical separation methods have been developed for several elements to improve the sensitivity of the analysis

  1. Certification of biological reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lanjewar, Mamata R.; Lanjewar, R.B.

    2014-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 21 minor and trace elements in two standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques ,Czechoslovakia. Also some biological standards such as Bowen's kale, cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of Reference Materials of Biological Matrices. (author)

  2. Activation analysis for food chemistry Pt. 3

    International Nuclear Information System (INIS)

    Szabo, S.A.; Gundorin, A.N.

    1982-01-01

    The nondestructive determination of K, Na, Ca, Mg, Cl and P content of animal tissues was reported. The IBR-30 (Dubna) reactor was used as the thermal neutron source for all the (n,ν) reactions needed for the analyses (tabulated), and as the source of fast neutrons for the (n,α) reaction of the P determination, too. Results and errors of the analyses (5-15%) were discussed comparing the reproducibility of the methods in case of different animal tissues, liver, bones, blood, etc. The nondestructive neutron activation multielemental analysis for food chemistry can be recommended in the case of a large scale monitoring program of food samples. (Sz.J.)

  3. Multielemental analysis of tissues from Cangrande della Scala, Prince of Verona, in the 14th century.

    Science.gov (United States)

    Apostoli, Pietro; De Palma, Giuseppe; Catalani, Simona; Bortolotti, Federica; Tagliaro, Franco

    2009-01-01

    Cangrande della Scala, Prince of Verona (Italy), died suddenly shortly after his triumph in the battle of Treviso (July 18, 1329). Thus, in the frame of a multidisciplinary paleo-pathological study, we carried out a multielemental analysis on the Prince's tissue specimens, including hair, liver, muscle, and bone, in order to characterize a multitissue profile of metallic elements in a nobleman of the 14th century. Biological specimens were analyzed by inductively coupled plasma-mass spectrometry. We were able to rule out arsenic poisoning as the primary cause of death. High levels of gold and silver in both hair and liver samples were probably due to prolonged contact of the mummy with precious metals in the funeral garments. High lead concentrations in both liver and bone tissue can be traced back to the ingestion of contaminated food and alcoholic beverages. Most of the essential elements were in the normal range of values for contemporary living people. The low arsenic and chromium levels in the Prince's tissues as compared to modern people would be suggestive of raised concentrations of both the elements in the present era, which are likely due to industrial pollution.

  4. Instrumental neutron activation analysis for the certification of biological reference materials

    International Nuclear Information System (INIS)

    Ambulkar, M.N.; Chutke, N.L.; Garg, A.N.

    1992-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 22 minor and trace constituents in two proposed Standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques, Czechoslovakia. Also some biological standards such as Bowen's Kale, Cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of reference materials of biological matrices. (author). 7 refs., 1 tab

  5. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  6. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  7. Characterization of obsidian devices come from San Miguel Ixtapan, Estado de Mexico by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Almazan T, M.G.; Jimenez R, M.; Monroy G, F.; Tenorio C, D.

    2002-01-01

    The Neutron Activation Analysis (NAA) is an efficient multielemental technique for determination of elements in low concentration (ppm), what has been result useful in the study of origin of archaeological material. In this work that technique was used for characterizing obsidian devices coming from the San Miguel Ixtapan site, Estado de Mexico and it was found that these come from three important beds which are: Sierra de Pachuca, Hidalgo, Zinapecuaro and Zinaparo-Varal in the Michoacan state. (Author)

  8. Determination of trace elements of Egyptian crops by neutron activation analysis Pt. 3

    International Nuclear Information System (INIS)

    Sherif, M.K.; Awadallah, R.M.; Amrallah, A.H.

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppm to ppb). (author)

  9. Analysis of Brazilian snake venoms by neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, M.; Vasconcellos, M.B.A.; Rogero, J.R.; Cruz, M.C.G.

    1991-01-01

    Instrumental neutron activation analysis (INAA) has been applied to multielemental determinations of Brazilian snake venoms from the species: Bothrops jararacussu, Crotalus durissus terrificus and Bothrops jararaca. Concentrations of Br, Ca, Cl, Cs, K, Mg, Na, Rb, Sb, Se and Zn have been determined in lyophilized venoms by using short and long irradiations in the IEA-RI nuclear reactor under a thermal neutron flux of 10 11 to 10 13 n · cm -2 · s -1 . The reference materials NIST Bovine Liver 1577 and IUPAC Bowen's Kale were also analyzed simultaneously with the venoms to evaluate the accuracy and the reproducibility of the method. The concentrations of the elements found in snake venoms from different species were compared. The Crotalus durissus terrificus venoms presented high concentration of Se but low concentrations of Zn when these results are compared with those obtained from genera Bothrops venoms. (author) 9 refs.; 2 tabs

  10. Multielemental analysis of osseous remains by x-ray fluorescence to determine types of diets from the Cultura Lima (II B.C. - VIII A.C)

    International Nuclear Information System (INIS)

    Montalvo B, A.

    1997-01-01

    The multielemental analysis of 29 human bone samples and sediments from the Lima Culture (III c. BC to IX c. AC) were analyzed by x-ray fluorescence technique with Cd-109 excitation source Si(Li) detector, Canberra associated electronic and PCA-II nucleus multichannel card, in order to determine to determine the diet type of these antique inhabitant. The elements found in bone rests were Ca, Sr, Zn, Mn, Fe, Ni, Cu, Rb, Zn and Pb, and As in one of the clavicles. In sediment samples we obtained a major quantity of elements. According to the Sr an Zn obtained values in osseous rest and the developed regression model, we can conclude that the ancient inhabitants of Lima Culture had an omnivorous feeding with a carnivore tendency due to its geographic location. (author). 35 refs., 9 figs., 10 tabs., 6 ills

  11. Radiochemical neutron activation analysis based multi-elemental analysis of high purity gallium

    International Nuclear Information System (INIS)

    Tashimova, F.A.; Sadikov, I.I; Salimov, M.I.; Zinov'ev, V.G.

    2006-01-01

    Full text: Gallium is one of the widely used materials in semiconductor and optoelectronics industry. Gallium is used to produce infrared detectors, piezoelectric sensors, high- and low-temperature transistors for space and defense technology. One of the most important requirements for semiconductor materials of gallium compounds is an excessive high purity for layers and films. Information on impurities (type of an impurity, concentration, character of distribution) is important as for better understanding of the physical and chemical processes taking place in formed semiconductor structures and for the 'know-how' of devices on their basis. The object of this work is to develop radiochemical neutron activation technique for analysis of high purity gallium. Irradiation of 0.1 g of gallium sample in neutron flux of 5·10 13 cm -2 s -1 for 5 hours will result in induced activity of more than 10 8 Bq, due to 72 Ga radionuclide, half-life of which is 14.1 hours. Therefore to perform instrumental NAA of gallium long period (10 day) cooling is required, and high sensitive determination of elements producing short- and long-lived radionuclides (T 1/2 72 Ga. We have studied the behavior of gallium in extraction-chromatographic system 'TBP-HCl'. The experiments have shown that higher factor of distribution (D) and capacity on gallium can be achieved when 'TBP-4M HCl' system is used. However more than 10 trace elements have high D and thus they cannot be separated from 72 Ga. To resolve the problem and increase the number of separated trace elements we have used preliminary satisfaction of chromatographic column with tellurium, which has D higher than the most of elements in 'TBP-4M HCl' system and thus suppresses extraction of elements. Distribution profile of gallium along the column and elution curve of 25 trace elements have been measured. Chemical yields of separated elements measured by using radiotracers are more than 93%. On the basis of the carried out researches

  12. Multielemental analysis of vegetarian human diets and dietary components by neutron activation

    International Nuclear Information System (INIS)

    Samudralwar, D.L.; Garg, A.N.

    1994-01-01

    Two vegetarian diet samples representative of the Indian sub-continent were prepared (in raw form) by the proportionate blending method for adolescent and adult age groups. These along with its components, viz. wheat, rice flours and pulses, were analyzed for 12 minor and trace elements by instrumental neutron activation analysis (INAA) and high resolution γ-ray spectrometry. Bowen's kale was also analyzed to check the accuracy of the method. The concentrations of Br, Co, Cu, Fe, K, Mn and P are comparable to the non-vegetarian American and European diets. Zinc concentrations are however lower than the recommended dietary allowances (RDA) and the western non-vegetarian diets. (orig.)

  13. Multielemental analysis of vegetarian human diets and dietary components by neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Samudralwar, D.L. (Nagpur Univ. (India). Dept. of Chemistry); Garg, A.N. (Nagpur Univ. (India). Dept. of Chemistry)

    1994-03-01

    Two vegetarian diet samples representative of the Indian sub-continent were prepared (in raw form) by the proportionate blending method for adolescent and adult age groups. These along with its components, viz. wheat, rice flours and pulses, were analyzed for 12 minor and trace elements by instrumental neutron activation analysis (INAA) and high resolution [gamma]-ray spectrometry. Bowen's kale was also analyzed to check the accuracy of the method. The concentrations of Br, Co, Cu, Fe, K, Mn and P are comparable to the non-vegetarian American and European diets. Zinc concentrations are however lower than the recommended dietary allowances (RDA) and the western non-vegetarian diets. (orig.)

  14. Multi-element analysis of wheat flour and white bread by neutron activation

    International Nuclear Information System (INIS)

    Godinez A, M.A.

    1994-01-01

    One of the best source of feeding even for the human being as for animals are the Cereals. Although they are mainly energetic aliment, due to its composition in starch, they are a very important source of proteins and amino acids. They contribute mineral elements to the diet. Even those elements constitute a very small part of the total diet, they take a very important place in many human metabolic processes. To make a multielemental analysis of an aliment is very important that we are based on a very sensible analytic technique so we are able to find them, just as the Neutronic Activation. This Nuclear technique allows you to make a qualitative and quantitative analysis of the elements that are in a sample, but it does n't show the way in which the elements are presented. It is based in turning those elements into radioactive ones through its exposition to an uniform and constant fluid of neutrons, so then its radioactivity can be determined. The present work has as a main purpose to make a multielemental analysis of the wheat flour and white bread through the Neutronic Activation Technique, using the comparator method and establishing previously the most appropriate work conditions as much irradiation as digestion and measuring of the radioactivity of the sample. In this way, it was able to know that the wheat flour has potassium, chlorine, magnesium, sodium, iron, zinc, manganese, rubidium and selenium elements in a concentration of 2000, 700, 500, 25, 18, 13, 5.5, 0.9 and 0.01 - 0.3 mg/g respectively. In an other hand it was found that the white bread has the same elements than the wheat flour but its concentration was: 1700, 9000, 400, 7000, 52, 13, 6, 1 and 0.05 - 0.3 mg/g respectively. (Author)

  15. Multielemental analysis of osseous remains by x-ray fluorescence to determine types of diets from the Cultura Lima (II B.C. - VIII A.C); Analisis multielemental de restos oseos por fluorescencia de rayos-x para la reconstruccion de dietas del periodo temprano en la Cultura de Lima

    Energy Technology Data Exchange (ETDEWEB)

    Montalvo B, A

    1998-12-31

    The multielemental analysis of 29 human bone samples and sediments from the Lima Culture (III c. BC to IX c. AC) were analyzed by x-ray fluorescence technique with Cd-109 excitation source Si(Li) detector, Canberra associated electronic and PCA-II nucleus multichannel card, in order to determine to determine the diet type of these antique inhabitant. The elements found in bone rests were Ca, Sr, Zn, Mn, Fe, Ni, Cu, Rb, Zn and Pb, and As in one of the clavicles. In sediment samples we obtained a major quantity of elements. According to the Sr an Zn obtained values in osseous rest and the developed regression model, we can conclude that the ancient inhabitants of Lima Culture had an omnivorous feeding with a carnivore tendency due to its geographic location. (author). 35 refs., 9 figs., 10 tabs., 6 ills.

  16. Multielemental analysis by neutron activation of sediments in the Ana Maria Gulf, Cuba

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Gandarias, D.; Calzavilla, R.; Garcia, G.

    1990-01-01

    In this paper general samples of marine sediments taken from six control stations of the Ana Maria Gulf (Cuba) were analyzed. For this purpose the thermal neutron activation analysis method was used. 18 elements were determinated. They are: Al, Ce, Co, Cs, Cr, Eu, Fe, Hf, La, Lu, Mo, Mn, Rb, Sc, Ta, Th, Yb and Zn. The accuracy varied between 5 and 30% for all elements. 10 refs

  17. Multi-elemental imaging of paraffin-embedded human samples by laser-induced breakdown spectroscopy

    Science.gov (United States)

    Moncayo, S.; Trichard, F.; Busser, B.; Sabatier-Vincent, M.; Pelascini, F.; Pinel, N.; Templier, I.; Charles, J.; Sancey, L.; Motto-Ros, V.

    2017-07-01

    Chemical elements play central roles for physiological homeostasis in human cells, and their dysregulation might lead to a certain number of pathologies. Novel imaging techniques that improve the work of pathologists for tissue analysis and diagnostics are continuously sought. We report the use of Laser-Induced Breakdown Spectroscopy (LIBS) to perform multi-elemental images of human paraffin-embedded skin samples on the entire biopsy scale in a complementary and compatible way with microscope histopathological examination. A specific instrumental configuration is proposed in order to detect most of the elements of medical interest (i.e. P, Al, Mg, Na, Zn, Si, Fe, and Cu). As an example of medical application, we selected and analysed skin biopsies, including healthy skin tissue, cutaneous metastasis of melanoma, Merkel-cell carcinoma and squamous cell carcinoma. Clear distinctions in the distribution of chemical elements are observed from the different samples investigated. This study demonstrates the high complementarity of LIBS elemental imaging with conventional histopathology, opening new opportunities for any medical application involving metals.

  18. Multielemental analysis of Brazilian milk powder and bread samples by neutron activation

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1988-01-01

    The concentrations of Na, Cl, Mn, Br, Fe, Zn, Rb, Sb, Sc, Cr, Al and Mg were determined in some types of bread and in some brands of milk powder consumed in the city of Sao Paulo (SP - Brasil), by instrumental neutron activation analysis. Radiochemical separations were carried out by means of retention of 24 Na on hydrated antimony pentoxide (HAP) from a 8N HCl solution, after digestion of the organic matter. Thus the radioisotopes 64 Cu, 69m Zn and 140 La could be determined in the effluent solution. The detection limits of the trace elements analyzed in bread and milk powder samples were determined using the Currie and Girardi criterions. (author) 22 refs.; 2 figs.; 7 tabs

  19. Multielemental analyses of tree rings by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Hall, G.S.

    1990-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) was evaluated for major, minor, trace, and ultra-trace elemental analyses of individual tree rings. The samples were obtained from an old-growth Douglas fir growing near Mount St. Helens volcano, and from trees at various other North American sites. Eightly percent of elements from Li to U had detection limits in the solid (wood) below 8.0 ng g -1 . Two anomalous peaks occur in Mount St. Helens samples at A.D. 1478 and 1490 that closely correlate with past eruptions of the volcano. These results show that ICP-MS is a rapid and sensitive analytical method for multielemental analyses of individual tree rings. (author) 16 refs.; 2 figs.; 2 tabs

  20. Activation analysis in a multitechnique study of trace element imbalances in age-related neurological diseases

    International Nuclear Information System (INIS)

    Ehmann, W.D.; Ding, X.X.; Khare, S.S.; Lovell, M.A.; Ni, B.F.; Tandon, L.; Vance, D.E.; Wenstrup, D.E.

    1993-01-01

    It has been suggested that several age-related neurological diseases such as Alzheimer's disease and amyotrophic lateral sclerosis may be related to environmental toxins. Bulk sample multielemental analyses by INAA alone are not adequate to define the role of trace elements in these diseases. A multitechnique approach has been developed that incorporates 14 MeV, instrumental reactor, radiochemical, and pre-irradiation chemical neutron activation analysis, together with laser microprobe mass spectrometry. The analytical scheme is able to provide bulk or protein normalized elemental concentrations, as well as microstructural, cellular, and subcellular localization information. (author) 21 refs.; 3 figs.; 3 tabs

  1. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques

    Energy Technology Data Exchange (ETDEWEB)

    Grindlay, Guillermo [Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, P.O. Box 99, 03080 Alicante (Spain)], E-mail: guillermo.grindlay@ua.es; Mora, Juan; Maestre, Salvador; Gras, Luis [Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, P.O. Box 99, 03080 Alicante (Spain)

    2008-11-23

    Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such

  2. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques

    International Nuclear Information System (INIS)

    Grindlay, Guillermo; Mora, Juan; Maestre, Salvador; Gras, Luis

    2008-01-01

    Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such

  3. A new method based on low background instrumental neutron activation analysis for major, trace and ultra-trace element determination in atmospheric mineral dust from polar ice cores

    Energy Technology Data Exchange (ETDEWEB)

    Baccolo, Giovanni, E-mail: giovanni.baccolo@mib.infn.it [Graduate School in Polar Sciences, University of Siena, Via Laterina 8, 53100, Siena (Italy); Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Clemenza, Massimiliano [INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Department of Physics, University of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Delmonte, Barbara [Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); Maffezzoli, Niccolò [Centre for Ice and Climate, Niels Bohr Institute, Juliane Maries Vej, 30, 2100, Copenhagen (Denmark); Nastasi, Massimiliano; Previtali, Ezio [INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Department of Physics, University of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy); Prata, Michele; Salvini, Andrea [LENA, University of Pavia, Pavia (Italy); Maggi, Valter [Department of Environmental Sciences, University of Milano-Bicocca, P.zza della Scienza 1, 20126, Milano (Italy); INFN, Section of Milano-Bicocca, P.zza della Scienza 3, 20126, Milano (Italy)

    2016-05-30

    Dust found in polar ice core samples present extremely low concentrations, in addition the availability of such samples is usually strictly limited. For these reasons the chemical and physical analysis of polar ice cores is an analytical challenge. In this work a new method based on low background instrumental neutron activation analysis (LB-INAA) for the multi-elemental characterization of the insoluble fraction of dust from polar ice cores is presented. Thanks to an accurate selection of the most proper materials and procedures it was possible to reach unprecedented analytical performances, suitable for ice core analyses. The method was applied to Antarctic ice core samples. Five samples of atmospheric dust (μg size) from ice sections of the Antarctic Talos Dome ice core were prepared and analyzed. A set of 37 elements was quantified, spanning from all the major elements (Na, Mg, Al, Si, K, Ca, Ti, Mn and Fe) to trace ones, including 10 (La, Ce, Nd, Sm, Eu, Tb, Ho, Tm, Yb and Lu) of the 14 natural occurring lanthanides. The detection limits are in the range of 10{sup −13}–10{sup −6} g, improving previous results of 1–3 orders of magnitude depending on the element; uncertainties lies between 4% and 60%. - Highlights: • A new method based on neutron activation for the multi-elemental characterization of atmospheric dust entrapped in polar ice cores is proposed. • 37 elements were quantified in μg size dust samples with detection limits ranging from 10{sup −13} to 10{sup −6} g. • A low background approach and a clean analytical protocol improved INAA performances to unprecedented levels for multi-elemental analyses.

  4. Two-year study of atmospheric aerosols in Alta Floresta, Brazil: Multielemental composition and source apportionment

    International Nuclear Information System (INIS)

    Maenhaut, Willy; Fernandez-Jimenez, Maria-Teresa; Rajta, Istvan; Artaxo, Paulo

    2002-01-01

    Atmospheric aerosol samples were collected nearly continuously from August 1996 until September 1998 at Alta Floresta in a primary forest region of the Amazon basin, Brazil. The sampling device consisted of a stacked filter unit (SFU), which separates the aerosol into a coarse (2-10 μm equivalent aerodynamic diameter (EAD)) and a fine (<2 μm EAD) size fraction. The coarse and fine filters of all SFU samples (205 in total) were analysed for the particulate mass (PM), black carbon (BC), and up to 47 elements (from Na upward). The multielemental analyses were done by a combination of PIXE and instrumental neutron activation analysis. Absolute principal component analysis was used for source (source type) identification and apportionment. Five components were identified in the fine size fraction, i.e. mineral dust, a biomass burning (pyrogenic) component (with PM, BC, S, K, Zn, Br, Rb and I, having loadings in the range 0.7-0.9), a Na/Ca component, a biogenic component (with P), and an almost pure Pb component. On average 67% of the fine PM was attributed to the pyrogenic component, 14% to the mineral dust, 7% each to the biogenic and Na/Ca components, and 4% to the Pb component. The relative contribution from the pyrogenic aerosol varied substantially with season, however. It was generally between 60% and 100% during the dry season. During the wet season, on the other hand, it often became insignificant. During that season, most of the fine aerosol was attributed to the biogenic component

  5. Multielemental fingerprinting as a tool for authentication of organic wheat, barley, faba bean, and potato

    DEFF Research Database (Denmark)

    Laursen, Kristian Holst; Schjørring, Jan Kofod; Olesen, Jørgen Eivind

    2011-01-01

    The multielemental composition of organic and conventional winter wheat, spring barley, faba bean, and potato was analyzed with inductively coupled plasma−optical emission spectrometry (ICP-OES) and −mass spectrometry (ICP-MS). The crops were cultivated in two years at three geographically...... different field locations, each accommodating one conventional and two organic cropping systems. The conventional system produced the highest harvest yields for all crops except the nitrogen-fixing faba bean, whereas the dry matter content of each crop was similar across systems. No systematic differences...

  6. Multielement neutron activation analysis of underground water samples

    International Nuclear Information System (INIS)

    Kusaka, Yuzuru; Tsuji, Haruo; Fujimoto, Yuzo; Ishida, Keiko; Mamuro, Tetsuo.

    1980-01-01

    An instrumental neutron activation analysis by gamma-ray spectrometry with high resolution and large volume Ge (Li) detectors followed by data processing with an electronic computer was applied to the multielemental analysis to elucidate the chemical qualities of the underground water which has been widely used in the sake brewing industries in Mikage, Uozaki and Nishinomiya districts, called as miyamizu. The evaporated residues of the water samples were subjected to the neutron irradiations in reactor for 1 min at a thermal flux of 1.5 x 10 12 n.cm -2 .sec -1 and for 30 hrs at a thermal flux of 9.3 x 10 11 n.cm -2 .sec -1 or for 5 hrs at a thermal flux of 3.9 x 10 12 n.cm -2 .sec -1 . Thus, 11 elements in the former short irradiation and 38 elements in the latter two kinds of long irradiation can be analyzed. Conventional chemical analysis including atomic absorption method and others are also applied on the same samples, and putting the all results together, some considerations concerning the geochemical meaning of the analytical values are made. (author)

  7. Determination of rare earths and traces of other elements by neutron activation analysis

    International Nuclear Information System (INIS)

    Atalla, L.T.; Mantovani, M.S.M.; Marques, L.S.

    A complete methodology for a multielemental analysis in geological material using the neutron activation technique was developed. 21 trace elements (9 of which are rare earths) were determined using thermal and epithermal neutron irradiations. Instrumetnal and radiochemical processing, applied to BCR-1 and G-2 geological standards, are described. Statistical tests carried out on G-2 data show an error smaller than 15% referring to all elements except Cr, Sb and Yb. The observed differences between are discussed. The good precision attained in this method is confirmed by its application to BCR-1 standard, which presents errors smaller than 4% for all elements except Nd, due to its intrinsic properties. The results from the present work are compared with those from other laboratories. (C.L.B.) [pt

  8. Neutron activation of building materials used in the reactor shield

    International Nuclear Information System (INIS)

    Hernandez, A.T.; Perez, G.; D'Alessandro, K.

    1993-01-01

    Cuban concretes and their main components (mineral aggregates and cement) were investigated through long-lived activation products induced by neutrons from a reactor. The multielemental content in the materials studied was obtained by neutron activation analysis in an IBR-2 reactor and gamma activation analysis in an MT-25 microtron from Join Institute of Nuclear Research of Dubna. After irradiation of building materials for 30 years by a neutron flow of unitary density, induced radioactivity was calculated according to experimental data. The comparative evaluation of different concretes aggregates and two types of cement related to the activation properties is discussed

  9. Determination of inorganic components in Brazilian medicinal plants by neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, M.; Vasconcellos, M.B.A.; Sertie, J.A.A.

    1990-01-01

    Instrumental neutron activation analysis (INAA) has been applied to multielemental determinations of medicinal extracts obtained from the plants Cordia verbenacea DC, Folidago microglossa DC, and Petiveria alliacea. Concentrations of the elements Al, Br, Ca, Cl, Co, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, and Zn have been determined in dried extracts of these herbs by short and long irradiations under a thermal neutron flux of 10 11 -10 13 n/cm 2 s in the IEA-R1 nuclear reactor. The NBS Tea Leaves (1572) and NIES Pepperbush reference materials were analyzed simultaneously with the plant extracts. The results obtained in these analyses have shown a good accuracy and reproducibility of the method. The relative errors and the relative standard deviations were less than 10% for most of the elements analyzed

  10. Determination of inorganic components in Brazilian medicinal plants by neutron activation analysis.

    Science.gov (United States)

    Saiki, M; Vasconcellos, M B; Sertié, J A

    1990-01-01

    Instrumental neutron activation analysis (INAA) has been applied to multielemental determinations of medicinal extracts obtained from the plants. Cordia Verbenacea DC, Folidago Microglossa DC, and Petiveria Alliacea. Concentrations of the elements Al, Br, Ca, Cl, Co, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, and Zn have been determined in dried extracts of these herbs by short and long irradiations under a thermal neutron flux of 10(11)-10(13) n/cm2s in the IEA-R1 nuclear reactor. The NBS Tea Leaves (1572) and NIES Pepperbush (1) reference materials were analyzed simultaneously with the plant extracts. The results obtained in these analyses have shown a good accuracy and reproducibility of the method. The relative errors and the relative standard deviations were less than 10% for most of the elements analyzed.

  11. Multielemental analysis to the profile sediments from several sites on the Havana Bay, by the Neutron activation analysis

    International Nuclear Information System (INIS)

    Diaz Riso, O.; Gelen, A.; Lopez, N.; Manso, M.V.; Graciano, A.M.; Nogueira, C.A.; Beltran, J.

    2003-01-01

    Instrumental neutron activation analysis (INAA) technique was employed to analyze the profile sediments from several sites on the Havana Bay, Cuba. Measurements of 24 heavy and trace elements in the sediments are reported. The results show the increment in the sediment pollution occurred in the 70-80 years of the last century. The data confirm that an anthropogenic input into the bay from domestic sewage and industries occurred

  12. Application of the neutron activation analysis method to the multielemental determination of food samples

    International Nuclear Information System (INIS)

    Maihara, V.A.

    1985-01-01

    The thermal neutron activation analysis method was applied to the determination of elements present at low concentrations and trace levels in samples of bread and milk powder using non-destructive analyses were based on gamma ray spectrometric measurements of samples and standards irradiated for periods which varied from some minutes to eight hours in a thermal neutron flux of about 10 12 n cm -2 s -1 . The concentrations obtained for milk powder were compared with the data obtained by other autors from different contries. For the bread, that comparison was not possible, because data about trace analysis in bread samples were not found. Besides, the results obtained for the various brands of bread and milk by means of non destructive and destructive analyses were compared using Student's t criterion. Some basic considerations about 'Detection Limit' were done, mainly in relation to its application in the technique used in the present work. The detection and determination limits of the trace elements analysed by destructive and non destructive techniques in bread and milk powder samples were determined using the Currie and Girardi methods. The precision of the analyses and the results obtained for the detection limits of the analysed trace elements are discussed. (Author) [pt

  13. Multielemental Determination of As, Bi, Ge, Sb, and Sn in Agricultural Samples Using Hydride Generation Coupled to Microwave-Induced Plasma Optical Emission Spectrometry.

    Science.gov (United States)

    Machado, Raquel C; Amaral, Clarice D B; Nóbrega, Joaquim A; Araujo Nogueira, Ana Rita

    2017-06-14

    A microwave-induced plasma optical emission spectrometer with N 2 -based plasma was combined with a multimode sample introduction system (MSIS) for hydride generation (HG) and multielemental determination of As, Bi, Ge, Sb, and Sn in samples of forage, bovine liver, powdered milk, agricultural gypsum, rice, and mineral fertilizer, using a single condition of prereduction and reduction. The accuracy of the developed analytical method was evaluated using certified reference materials of water and mineral fertilizer, and recoveries ranged from 95 to 106%. Addition and recovery experiments were carried out, and the recoveries varied from 85 to 117% for all samples evaluated. The limits of detection for As, Bi, Ge, Sb, and Sn were 0.46, 0.09, 0.19, 0.46, and 5.2 μg/L, respectively, for liquid samples, and 0.18, 0.04, 0.08, 0.19, and 2.1 mg/kg, respectively, for solid samples. The method proposed offers a simple, fast, multielemental, and robust alternative for successful determination of all five analytes in agricultural samples with low operational cost without compromising analytical performance.

  14. Multielemental determination in Citrus spp bee honey samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Favaro, D.I.T.; Vasconcellos, M.B.A.; Pamplona, B.

    1990-07-01

    Recently interest has grown in the determination of the concentration of inorganic chemical elements in honey bee samples, due its utilization as indicator of environmental pollution in several countries of Europe. In the present work, a method was developed to determine some essential and potentially inorganic elements in honey bee samples by intrumental neutrons activation analysis followed by high resolution gamma ray spectrometry. The honey samples were neutron irradiated during differents times at the nuclear research reactor IEA-Rl of the IPEN-CNEN/SP. The elements Na, Cl, K, Mg and Mn were determined using irradiations of 30 minutes under a thermal neutron flux of 10 12 n.cm -2 .s -1 . With 16 hours of irradiation under a flux of 10 13 n.cm -2 .s -1 and different cooling times, the elements Br, Ca, Au, Sb, Cs, Rb, Zn, Sc, Fe, Co and La were determined. The concentration of the analyzed elements ranged from ng/g to mg/g. In the future, different kinds of bee honey will be analyzed and the characteristic chemical composition of each one will be established. Based on these elemental concentration data, the relationship between the mineral composition of bee honey and its geographical origin can be studied. (author) [pt

  15. Elemental investigation of (Al-Cu) alloys and some geological samples using neutron activation and XRF analysis techniques

    International Nuclear Information System (INIS)

    Hammad, E.A.M.

    2012-01-01

    Neutron activation analysis (NAA) using k 0 - standardization (k 0 -NAA) is well known method for multi-elemental analysis. The method is used to analyze different samples belonging to different fields. In addition, X- ray fluorescence (XRF) is also used for multi-elemental analysis. XRF complements NAA methods. Both methods were used for investigation of some iron ores and aluminum- cupper alloy (Al-Cu) samples. Elemental concentration of Iron ores and Al-Cu alloy samples were determined by k 0 - NAA and XRF methods. The iron ore samples were collected from Wadi Kareim and Umm Nar sites (the Eastern desert of Egypt). Six and two samples representing the ores of Wadi Kareim and Umm Nar, respectively altogether with the standard samples consisting of Fe, Au , Zr and W and the certified reference sample IAEA Soil-7 were irradiated in one of the irradiated boxes at the Second Egyptian Research Reactor (ETRR- 2). The induced activities were counted using an efficiency calibrated HPGe detector systems. The neutron spectrum parameters α and f characterizing the neutron irradiation position that are needed in applying k 0 -NAA method were determined using the activation product of Zr , Au, Fe and W and found α≅ - 0.048 ±0.002 and f ≅ 38± k 0 -NAA method was applied to determine the elemental concentrations in the two iron ore samples. The concentrations determined were found to vary erratically form one sample to another. The results were discussed and compared with similar results in literature. The accuracy of the k 0 - NAA method was checked by determining the elemental concentration in the IAEA-Soil 7 reference sample. The obtained results are compared with the recommended values. Good agreements were found within 10 %. Short time neutron activation analysis (STNAA) was carried out to determine concentration of major elements in Al-Cu alloy samples. Three (Al-Cu) alloys samples with different concentrations of Cu (2, 3.5 and 5 %) altogether. Au standard sample

  16. Application of the neutron activation analysis method to the multielemental determination of food samples

    International Nuclear Information System (INIS)

    Maihara, V.A.

    1985-01-01

    The application of thermal neutron activation analysis method for determining elements presented at low concentration and level of traces in bread and dried milk samples, using non-destructive and chemical analyses, was studied. The non-destructive analyses were based on measurements of gamma spectrometry of samples and standards irradiated by thermal neutron flux on the order of 10 12 n cm -2 s -1 . The irradiation time varied from some minutes to 8 hours. The Na, Cl, Mn, Br, Fe, Zn, Rb, Sb, Cr and Sc elements in bread samples were determined. The Na, K, Cl, Ca, Mg, Br, Al, Zn, Rb, Sb and Cr elements in dried milk samples were determined. In destructive analysis, the 24 Na radioisotope was separeted by retention on hydrated antimony pentoxide column from 8N HCL after digestion of organic matter. The bread was dissolved in HNO 3 concentrated and 70% of HCLO 4 and the dried milk was dissolved in HNO 3 concentrated and H 2 O 2 . The 64 Cu, 69m Zn and 140 La radioisotopes determined. The concentrations obtained for dried milk were compared with data obtained by other authors from different contries. Basic considerations on detection limit related to its application on the technique used in this work, were done. The detection limits and trace elements using the Currie and Girardi methods were determined. The accuracy of results obtained for trace element detection limits is discussed. (Author) [pt

  17. Metal and trace element assessment of estuary sediments from Santos, Brazil, by neutron activation and atomic absorption techniques

    International Nuclear Information System (INIS)

    Amorim, Eduardo P.; Favaro, Deborah I.T.; Berbel, Glaucia B.B.; Braga, Elisabete S.

    2007-01-01

    In order to better understanding geochemical and environmental processes and their possible changes due to anthropogenic activities trace metal analyses and their distribution in marine sediments are commonly undertaken. The present study reports result concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirteen bottom sediment samples (SV0501 to SV0513) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao, Vicente de Carvalho and Santos' Bay, in the summer of 2005. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). For total mercury determination cold vapor atomic absorption technique (CV AAS) was employed. In both cases methodology validation was performed by certified reference material analyses. The results obtained for multielemental concentrations in the sediment samples were compared with NASC (North American Shale Composite) values. The concentration values obtained for As and metals Cr, Hg and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values). In general, the samples located near the Cubatao region showed higher concentrations for all elements analyzed probably due to the high impact of industrial activities. (author)

  18. Metal and trace element assessment of estuary sediments from Santos, Brazil, by neutron activation and atomic absorption techniques

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Eduardo P.; Favaro, Deborah I.T. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: ducamorim@yahoo.com.br; defavaro@ipen.br; Berbel, Glaucia B.B.; Braga, Elisabete S. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. Oceanografico. Lab. de Nutrientes, Micronutrientes e Tracos nos Oceanos - LABNUT]. E-mail: edsbraga@usp.br

    2007-07-01

    In order to better understanding geochemical and environmental processes and their possible changes due to anthropogenic activities trace metal analyses and their distribution in marine sediments are commonly undertaken. The present study reports result concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirteen bottom sediment samples (SV0501 to SV0513) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao, Vicente de Carvalho and Santos' Bay, in the summer of 2005. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). For total mercury determination cold vapor atomic absorption technique (CV AAS) was employed. In both cases methodology validation was performed by certified reference material analyses. The results obtained for multielemental concentrations in the sediment samples were compared with NASC (North American Shale Composite) values. The concentration values obtained for As and metals Cr, Hg and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values). In general, the samples located near the Cubatao region showed higher concentrations for all elements analyzed probably due to the high impact of industrial activities. (author)

  19. A provenance study of coffee by photon activation analysis

    International Nuclear Information System (INIS)

    Sun, Z.J.; Wells, D.P.; Maschner, H.; Idaho State University, Pocatello, ID; Idaho State University, Pocatello, ID; Benson, B.

    2013-01-01

    Photon activation analysis (PAA) is a multi-elemental radioanalytical technique in trace elements analysis with high accuracy and precision. Researchers at the Idaho accelerator center performed PAA analysis on coffee samples from several locations around the world as an initial step in assessing the relationship between trace elements in illicit drugs and the soils in which they were grown. The preliminary results show coffees from different locations have different concentrations of trace elements. In the three cases where we have soil samples, the matrices of elements in the coffee samples are closely related to the matrices of the elements of the local soil samples. The majority of trace elemental content is similar to that of the local soil sample in which the coffee is planted. It may be that coffee assimilates numerous elements from the soil where it is grown in similar ratios as is found in the soil. Thus, it is conceivable that the elemental content could serve as 'fingerprint' to trace the origins of the coffee. To verify our analytical results we applied X-ray fluorescence (XRF) methods as well. Our PAA results are consistent with XRF experimental data. The future of tracing the origin of illicit drugs with the PAA technique is promising. (author)

  20. Characterization of obsidian devices come from San Miguel Ixtapan, Estado de Mexico by Neutron Activation Analysis; Caracterizacion de artefactos de obsidiana provenientes de San Miguel Ixtapan, Estado de Mexico con Analisis por Activacion Neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Almazan T, M.G.; Jimenez R, M.; Monroy G, F.; Tenorio C, D. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The Neutron Activation Analysis (NAA) is an efficient multielemental technique for determination of elements in low concentration (ppm), what has been result useful in the study of origin of archaeological material. In this work that technique was used for characterizing obsidian devices coming from the San Miguel Ixtapan site, Estado de Mexico and it was found that these come from three important beds which are: Sierra de Pachuca, Hidalgo, Zinapecuaro and Zinaparo-Varal in the Michoacan state. (Author)

  1. Neutron activation analysis on sediments from Victoria Land, Antarctica. Multi-elemental characterization of potential atmospheric dust sources

    International Nuclear Information System (INIS)

    Baccolo, G.; Maggi, V.; Baroni, C.; Clemenza, M.; Motta, A.; Nastasi, M.; Previtali, E.; University of Milano-Bicocca, Milan; Delmonte, B.; Salvatore, M.C.

    2014-01-01

    The elemental composition of 40 samples of mineral sediments collected in Victoria Land, Antarctica, in correspondence of ice-free sites, is presented. Concentration of 36 elements was determined by instrumental neutron activation analysis, INAA. The selection of 6 standard reference materials and the development of a specific analytical procedure allowed to reduce measurements uncertainties and to verify the reproducibility of the results. The decision to analyze sediment samples from Victoria Land ice-free areas is related to recent investigations regarding mineral dust content in the TALos Dome ICE core (159deg11'E; 72deg49'S, East Antarctica, Victoria Land), in which a coarse local fraction of dust was recognized. The characterization of Antarctic potential source areas of atmospheric mineral dust is the first step to identify the active sources of dust for the Talos Dome area and to reconstruct the atmospheric pathways followed by air masses in this region during different climatic periods. Principal components analysis was used to identify elements and samples correlations; attention was paid specially to rare earth elements (REE) and incompatible/compatible elements (ICE) in respect to iron, which proved to be the most discriminating elemental groups. The analysis of REE and ICE concentration profiles supported evidences of chemical weathering in ice-free areas of Victoria Land, whereas cold and dry climate conditions of the Talos Dome area and in general of East Antarctica. (author)

  2. Use of high-intensity sonication for pre-treatment of biological tissues prior to multielemental analysis by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De La Calle, Inmaculada; Costas, Marta; Cabaleiro, Noelia; Lavilla, Isela; Bendicho, Carlos

    2012-01-01

    In this work, two ultrasound-based procedures are developed for sample preparation prior to determination of P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se and Sr in biological tissues by total reflection X-ray fluorescence spectrometry. Ultrasound-assisted extraction by means of a cup-horn sonoreactor and ultrasonic-probe slurry sampling were compared with a well-established procedure such as magnetic agitation slurry sampling. For that purpose, seven certified reference materials and different real samples of animal tissue were used. Similar accuracy and precision is obtained with the three sample preparation approaches tried. Limits of detection were dependent on both the sample matrix and the sample pre-treatment used, best values being achieved with ultrasound-assisted extraction. Advantages of ultrasound-assisted extraction include reduced sample handling, decreased contamination risks (neither addition of surfactants nor use of foreign objects inside the extraction vial), simpler background (no solid particles onto the sample carrier) and improved recovery for some elements such as P. A mixture of 10% v/v HNO 3 + 20–40% v/v HCl was suitable for extraction from biological tissues. - Highlights: ► We implement high-intensity sonication for pre-treatment of biological tissues. ► Multielemental analysis is performed by total reflection X-ray spectrometry. ► Ultrasound-based procedures are developed and compared to conventional slurry preparation. ► Features such as background, recovery and sample handling are favored by using ultrasonic extraction.

  3. Comparison of Elemental Composition in Korean Irradiated Foods using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Lee, Kye Hong; Kim, Young Jin; Choi, Jong Il; Lee, Joo Eun

    2010-01-01

    The information and role of trace mineral elements from an intake of created and processed foodstuff are important as a indicator of human health and nutritional parameter, as well as a quality control of food and diet. Particularly, special food created for consumption by astronauts in outer space may differ with common food on the earth in order to compensate a decrease of taste and nutrition by strong cosmic rays, a state of nongravitation, low pressure, and enclosed space environment. In April 2008, Korea's first astronaut became a crew member of the international space station and she was brought special space versions of Korea's national dishes such as Kimchi, boiled rice, hot red paste, green tea, ramyun, and so on. Accurate quantitative analysis of trace elements in various kinds of biological samples is also important for data quality. Neutron activation analysis is a sensitive, non-destructive, multi-elemental analytical method, and is proper for tracing elements in a biological sample in order to avoid loss and contamination by chemical pretreatment. This study analyses the distribution of concentrations for both essential and toxic elements in six kinds of Korean space foods developed by KAERI. The quantitative analytical results from instrumental neutron activation analysis are presented

  4. Synthetic multielement standards used for instrumental neutron activation analysis as rock imitations

    International Nuclear Information System (INIS)

    Leypunskaya, D.I.; Drynkin, V.I.; Belenky, B.V.; Kolomijtsev, M.A.; Dundera, V.Yu.; Pachulia, N.V.

    1975-01-01

    Complex (multielemental) standards representing microelement composition of standard rocks such as trap ST-1 (USSR), gabbrodiorite SGD-1 (USSR), albitized granite SG-1 (USSR), basalt BCR-1 (USA) and granodiorite GSP-1 (USA) have been synthesized. It has been shown that the concentration of each microelement in the synthetic standards can be given with a high precision. Comparative investigation has been carried out of the synthetic imitations and the above natural standard rocks. It has been found that the result of the instrumental neutron activation analysis using the synthetic standards is as good as in the case when natural standard rocks are used. The results obtained have been also used for substantiation of the versatility of the method used for standard preparation, i.e. a generalization has been made of a possibility of using this method for the preparation of synthetic standards representing the microelement composition of any natural rocks with various compositions and concentrations of microelements. (T.G.)

  5. Radiochemical separation and their application to neutron activation analysis technique

    International Nuclear Information System (INIS)

    Turel, Z.R.

    2013-01-01

    The present paper discusses the development of some new, rapid and selective method for the radiochemical separation and estimation of elements such as, Co(II) 2-3 , Ir(III) 4 , Au(III) 5 , Pt(IV), Pd(II), Os(IV) 6 , Cu(II), Ag(I), Mo(VI), Ni(II), Zn(II), Cd(II), Hg(II), Cs(I), Sb(III), La(III), Sc(III) etc. using various reagents. Various parameters such as pH, time of equilibrium, effect of anions and cations, effect of reagent etc. has been determined employing tracers of the elements under consideration and will be discussed. The method is made highly selective by the use of appropriate masking agent. The stoichiometry of metal reagent is determined by the substoichiometric method. Some examples of multielemental radiochemical separation methods thus developed which have been applied in determining the elements by radiochemical thermal neutron activation analysis will be presented and discussed. The implications of the results on the reference system will also be accounted. Statistical evaluation with reference to accuracy, precision and sensitivity will also be presented

  6. Determination of elemental composition in dietary supplements by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vitor I.; Saiki, Mitiko, E-mail: vitor.ito@outlook.com, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Dietary supplements intake has grown in the last years because of their potential health benefits. This supplementation is very common among athletes, elderly population and consumers that want to increase the total daily nutrient intake. Consequently, elemental composition evaluation in these supplements is of great interest due to its increasingly high consumption and the brand variety offered in the market. This study aimed to evaluate the elemental composition in three types of dietary supplements acquired in a pharmacy and drugstore in Sao Paulo city. Concentrations of As, Br, Ca, Co, Cr, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn were determined in these supplements by applying neutron activation analysis (NAA) followed by a gamma ray spectrometry. from the concentrations obtained in the dietary supplement analyses, the data obtained were compared to the values presented on the product label. These comparisons indicated in general, a good agreement of the data obtained and the values of the product label depending on the supplement. From the results obtained it can be concluded that NAA is an important tool for the analysis of this type of products due to its reliability of results and its multielemental character. (author)

  7. Determination of elemental composition in dietary supplements by neutron activation analysis

    International Nuclear Information System (INIS)

    Souza, Vitor I.; Saiki, Mitiko

    2015-01-01

    Dietary supplements intake has grown in the last years because of their potential health benefits. This supplementation is very common among athletes, elderly population and consumers that want to increase the total daily nutrient intake. Consequently, elemental composition evaluation in these supplements is of great interest due to its increasingly high consumption and the brand variety offered in the market. This study aimed to evaluate the elemental composition in three types of dietary supplements acquired in a pharmacy and drugstore in Sao Paulo city. Concentrations of As, Br, Ca, Co, Cr, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn were determined in these supplements by applying neutron activation analysis (NAA) followed by a gamma ray spectrometry. from the concentrations obtained in the dietary supplement analyses, the data obtained were compared to the values presented on the product label. These comparisons indicated in general, a good agreement of the data obtained and the values of the product label depending on the supplement. From the results obtained it can be concluded that NAA is an important tool for the analysis of this type of products due to its reliability of results and its multielemental character. (author)

  8. Determination of trace elements in aerosols from the antarctic peninsula by neutron activation analysis

    International Nuclear Information System (INIS)

    Loureiro, A.L.M.

    1989-01-01

    In this work the neutron activation method was applied to carry out multielemental analysis in aerosols collected in the Brazilian Station 'Comandante Ferraz', located on King George Island, at the Antarctic Peninsula, during 1986 and 1987. The aerosols were collected on 0.45 μum Millipore-MF filter paper, type HA. The analytical method was based on the simultaneous irradiations of filters and synthetic standards in the IEA-R1 nuclear reactor under a thermal neutron flux of about 10 12 n cm -2 s -1 . The induced radioactivity was measured in a gamma ray spectrometer after suitable cooling times. Samples were irradiated twice, with irradiation times varying from 5 minutes to 24 hours. The elements Na, Al, Cl, K, Ca, Sc, V, Mn, Fe, Zn, Br, Sb, La, Au and Th were determined with concentration levels from ng/m 3 to pg/m 3 [pt

  9. Determination of trace elements of Egyptian crops by neutron activation analysis. Pt. 3. Trace elements in African tea, ginger, canella bark, black pepper, sesame, lady's fingers, jew's mallow, tomatos, cucumber and marrow

    Energy Technology Data Exchange (ETDEWEB)

    Sherif, M K; Awadallah, R M; Amrallah, A H [Assiut Univ. (Egypt)

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppM to ppB).

  10. Determination of some elements in Ageratum conyziodes, a tropical medicinal plant, using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Dim, L.A.; Funtua, I.I.; Umar, I.M.; Gwozdz, R.

    2004-01-01

    Instrumental neutron activation analysis was utilized for the multielemental determination of elements in the roots of Ageratum conyzoides, a tropical medicinal plant that is used locally for the cure of various diseases in Nigeria. The concentrations of Al, Ba, Br, Ca, Co, Cr, Fe, K, Mg, Mn, Na, Rb, Sc, Sr, V and Zn were analyzed with the 250 kW Triga Reactor at the Atominstitut, Vienna. The essential elements K, Na, Ca, Fe, Mg, Mn and Zn and the non-essential elements Al, Ba, Sr and Rb are present in significant concentrations. Other elements including Co, Cr, Sc and V are present at trace levels. The likely implication of these elements in restoring and maintaining good health is discussed. Quality control on the measurements was carried out by analyzing standard reference materials alongside the samples. (author)

  11. Multielemental analysis of 18 essential and toxic elements in amniotic fluid samples by ICP-MS: Full procedure validation and estimation of measurement uncertainty.

    Science.gov (United States)

    Markiewicz, B; Sajnóg, A; Lorenc, W; Hanć, A; Komorowicz, I; Suliburska, J; Kocyłowski, R; Barałkiewicz, D

    2017-11-01

    Amniotic fluid is the substantial factor in the development of an embryo and fetus due to the fact that water and solutes contained in it penetrate the fetal membranes in an hydrostatic and osmotic way as well as being swallowed by the fetus. Elemental composition of amniotic fluid influences the growth and health of the fetus, therefore, an analysis of amniotic fluid is important because the results would indicate abnormal levels of minerals or toxic elements. Inductively coupled plasma mass spectroscopy (ICP-MS) is often used for determination of trace and ultra-trace level elements in a wide range of matrices including biological samples because of its unique analytical capabilities. In the case of trace and ultra-trace level analysis detailed characteristics of analytical procedure as well as properties of the analytical result are particularly important. The purpose of this study was to develop a new analytical procedure for multielemental analysis of 18 elements (Al, As, Ba, Ca, Cd, Co, Cr, Cu, Mg, Mn, Ni, Pb, Sb, Se, Sr, U, V and Zn) in amniotic fluid samples using ICP-MS. Dynamic reaction cell (DRC) with two reaction gases, ammonia and oxygen, was involved in the experiment to eliminate spectral interferences. Detailed validation was conducted using 3 certified reference mterials (CRMs) and real amniotic fluid samples collected from patients. Repeatability for all analyzed analytes was found to range from 0.70% to 8.0% and for intermediate precision results varied from 1.3% to 15%. Trueness expressed as recovery ranged from 80% to 125%. Traceability was assured through the analyses of CRMs. Uncertainty of the results was also evaluated using single-laboratory validation approach. The obtained expanded uncertainty (U) results for CRMs, expressed as a percentage of the concentration of an analyte, were found to be between 8.3% for V and 45% for Cd. Standard uncertainty of the precision was found to have a greater influence on the combined standard uncertainty

  12. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  13. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    International Nuclear Information System (INIS)

    Amorim, Eduardo P.; Favaro, Deborah I.T.; Berbel, Glaucia; Braga, Elisabete S.

    2009-01-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  14. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Eduardo P.; Favaro, Deborah I.T., E-mail: ducamorim@yahoo.com.b, E-mail: defavaro@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Berbel, Glaucia; Braga, Elisabete S., E-mail: edsbraga@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Inst. Oceanografico. Lab. de Nutrientes, Micronutrientes e Tracos nos Oceanos (LABNUT)

    2009-07-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  15. Neutron activation analysis of alternative phosphate rocks used in animal nutrition

    International Nuclear Information System (INIS)

    Canella, Artur A.; Ferreira, Walter M.

    2005-01-01

    Since 1980's, Bovine Sponghiform Encephalophaty has insidiously created a fierce battleground between farmers, scientists, environmentalists and consumers. The use of meat and bone meals is currently prohibited in ruminant feeds throughout the world. Some inorganic sources offer the combination of high phosphorus content and acceptable animal digestibility make them options as supplemental phosphorus, for instance phosphate rocks, general term applied to minerals valued chiefly for their phosphorus content. However, phosphate rocks are long been known containing hazardous elements, make them sometimes unsuitable for animal nutrition. Neutron Activation Analysis has been supportive to the mineral evaluation of alternative phosphate rocks. This evaluation is subject of on-going doctoral thesis which has been carried-out by the main author. The NAA method has been very efficient due to its highly sensitive and multi-elemental nature. In this paper results of Vanadium content from three different phosphate rocks are presented. Their values have been pointed out that Brazilian phosphate rocks present hazardous elements at the same levels of phosphate rocks from some countries of Africa, North America and Middle East, data from our study (Brazilian data) and FAO - Food and Agriculture Organization (others countries). (author)

  16. Application of neutron activation analysis to the monitoring of trace elements in Brazilian foodstuffs

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.; Maihara, V.A.; Munita, C.J.A.S.; Favaro, D.I.T.; Armelin, M.J.A.

    1994-01-01

    Due to lack of data on trace element levels in Brazilian foodstuffs, nuclear analytical techniques were used to determine about twenty elements in foods samples collected from local markets of the city of Sao Paulo. Drinking water was also analyzed. The methods employed were mainly instrumental and radiochemical neutron activation analysis. In the case of the analysis of toxic elements, such as mercury, selenium, arsenic and antimony, the purely instrumental approach failed in yielding results for very low concentrations of these elements. For INAA, samples and multielemental synthetic standards were irradiated in the IEA R1 research reactor for periods of time ranging from minutes to several hours, under thermal neutron fluxes from 10 11 to 10 13 n·cm -2 ·s -1 ; after suitable cooling times, γ-ray spectra were measured using a Ge(Li) or Ge solid state detector. The RNAA approach involved the distillation of mercury and selenium in HBr medium; selenium was then reduced to the metal form with sodium metabisulphide and mercury was precipitated as sulphide with thioacetamide. For water analysis, a preconcentration procedure based on retention of several elements in a Chelex-100 resin was employed. The elements retained were Hg, Cr, Zn, Fe, Co while Se was measured in the effluent after absorption on active charcoal. The levels of the trace inorganic elements determined in the Brazilian foodstuffs analyzed were always below the levels established by the existing regulations in our country. (author). 16 refs, 18 tabs

  17. Estudio sobre la aplicación del análisis por activación en reactores nucleares a la determinación multielemental rutinaria en rocas silicatadas

    OpenAIRE

    Espinosa, Ricardo; Cohen, Marcos

    1985-01-01

    Se investigan comparativamente las posibilidades del análisis por activación, con neutrones predominantemente térmicos (AANT) y epitérmicos (AANE), para le determinación multielemental no destructiva de muestras geológicas silicatadas. Se describe el método empleado para el análisis de 23 elementos de materiales de referencia del U.S.G.S. y granitos argentinos, aplicable a la determinación rutinaria.

  18. Multielemental analysis of geological materials using EDXRF

    International Nuclear Information System (INIS)

    Fernández, Zahily Herrero; Santos Júnior, José A. dos; Amaral, Romilton dos Santos; Santos, Josineide Marques do Nascimento; Rojas, Lino A. Valcárcel; França, Elvis Joacir de

    2017-01-01

    In northeastern Brazil, there are few studies about the metal pollution of surface soils and for the first time it will be studied heavy metals contamination in soils with different cover land. The State of Pernambuco is representative of the Brazilian Northeast region in relation to the variability of climatic conditions, soil types, cover and land use. Based on this, this paper provides information on the determination of metals in soil samples collected in Pernambuco, Brazil. The analysis of Al, Ca, Fe, K, Mg, Mn, Ni, Pb, Si, Sr, Ti and Zn were performed using Energy Dispersive X Ray Fluorescence (EDXRF). The 316 locations studied were specifically selected taking into account the different land use of soil. Analytical curves were obtained by means of the analysis of certified reference materials, for quantify the metals. The regression coefficients of the analytical curves were higher than 0.99. The quality of the analytical procedure was demonstrated at a 95% confidence level. The analysis of diverse geological samples from Pernambuco indicated higher concentrations of Ni and Zn in sugarcane, with maximum values of 41 mg kg -1 and 118 mg kg -1 , respectively and agricultural areas (41 mg kg -1 and 127 mg kg -1 , respectively). The trace element Sr was mainly enriched in urban soils with values of 400 mg kg -1 . According to the results, the EDXRF method was successfully implemented, providing some chemical tracers for the quality assessment of tropical soils and sediments. (author)

  19. Neutron activation analysis of high pure uranium using preconcentration

    International Nuclear Information System (INIS)

    Sadikov, I.I.; Rakhimov, A.V.; Salimov, M.I.; Zinov'ev, V.G.

    2006-01-01

    Full text: Uranium and its compounds are used as nuclear fuel, and requirements for purity of initial uranium are very high. Therefore highly sensitive and multielemental analysis of uranium is required. One of such methods is neutron activation analysis (NAA). During irradiation of uranium by nuclear reactor neutrons the induced radioactivity of a sample is formed by uranium radionuclide 239 U (T 1/2 = 23,4 min.) and its daughter radionuclide 239 Np (T 1/2 = 2,39 d). Short-lived 239 U almost completely decays in 24 hours after irradiation and the radioactivity of the sample is mainly due to 239 Np and is more than 10 9 Bq for 0.1 g of uranium sample (F = 1*10 14 cm -2 s -1 , t irr . = 5 h). That is why nondestructive determination of the impurities is impossible and they should be separated from 239 Np. When irradiated uranium yields fission products - radionuclides of some elements with mass numbers 91-104 and 131-144. The main problem in NAA of uranium is to take into account correctly the influence of fission products on the analysis results. We have developed a radiochemical separation procedure for RNAA of uranium [1]. Comparing the results of analysis carried out by radiochemical NAA and instrumental NAA with preconcentration of trace elements can be used for evaluating the interference of fission products on uranium analysis results. Preconcentration of trace elements have been carried out by extraction chromatography in 'TBP - 6M HNO 3 ' system [1]. Experiments have shown that if 0.1 g uranium sample is taken for analysis (F = 1*10 14 cm -2 s -1 , t irr . =5 h) the apparent concentration of Y, Zr, Mo, Cs, La, Ce, Pr, Nd exceeds the true concentration by 2500-3000 times and so determination of these elements is not possible by radiochemical NAA. (author)

  20. Computer simulation of multi-elemental fusion reactor materials

    International Nuclear Information System (INIS)

    Voertler, K.

    2011-01-01

    Thermonuclear fusion is a sustainable energy solution, in which energy is produced using similar processes as in the sun. In this technology hydrogen isotopes are fused to gain energy and consequently to produce electricity. In a fusion reactor hydrogen isotopes are confined by magnetic fields as ionized gas, the plasma. Since the core plasma is millions of degrees hot, there are special needs for the plasma-facing materials. Moreover, in the plasma the fusion of hydrogen isotopes leads to the production of high energetic neutrons which sets demanding abilities for the structural materials of the reactor. This thesis investigates the irradiation response of materials to be used in future fusion reactors. Interactions of the plasma with the reactor wall leads to the removal of surface atoms, migration of them, and formation of co-deposited layers such as tungsten carbide. Sputtering of tungsten carbide and deuterium trapping in tungsten carbide was investigated in this thesis. As the second topic the primary interaction of the neutrons in the structural material steel was examined. As model materials for steel iron chromium and iron nickel were used. This study was performed theoretically by the means of computer simulations on the atomic level. In contrast to previous studies in the field, in which simulations were limited to pure elements, in this work more complex materials were used, i.e. they were multi-elemental including two or more atom species. The results of this thesis are in the microscale. One of the results is a catalogue of atom species, which were removed from tungsten carbide by the plasma. Another result is e.g. the atomic distributions of defects in iron chromium caused by the energetic neutrons. These microscopic results are used in data bases for multiscale modelling of fusion reactor materials, which has the aim to explain the macroscopic degradation in the materials. This thesis is therefore a relevant contribution to investigate the

  1. Multielemental analysis of geological materials using EDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Fernández, Zahily Herrero; Santos Júnior, José A. dos; Amaral, Romilton dos Santos; Santos, Josineide Marques do Nascimento; Rojas, Lino A. Valcárcel, E-mail: zahily1985@gmail.com, E-mail: jaraujo@ufpe.br, E-mail: romilton@ufpe.br, E-mail: josineide.santos@ufpe.br, E-mail: linomarvic@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil). Departamento de Energia Nuclear; Alvarez, Juan R. Estevez, E-mail: jestevez@ceaden.edu.cu [Centro de Aplicaciones Tecnológicas y Desarrollo Nuclear, Havana (Cuba); França, Elvis Joacir de, E-mail: ejfranca@gmail.com [Centro Regional de Ciências Nucleares do Nordeste (CRCN-EN/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    In northeastern Brazil, there are few studies about the metal pollution of surface soils and for the first time it will be studied heavy metals contamination in soils with different cover land. The State of Pernambuco is representative of the Brazilian Northeast region in relation to the variability of climatic conditions, soil types, cover and land use. Based on this, this paper provides information on the determination of metals in soil samples collected in Pernambuco, Brazil. The analysis of Al, Ca, Fe, K, Mg, Mn, Ni, Pb, Si, Sr, Ti and Zn were performed using Energy Dispersive X Ray Fluorescence (EDXRF). The 316 locations studied were specifically selected taking into account the different land use of soil. Analytical curves were obtained by means of the analysis of certified reference materials, for quantify the metals. The regression coefficients of the analytical curves were higher than 0.99. The quality of the analytical procedure was demonstrated at a 95% confidence level. The analysis of diverse geological samples from Pernambuco indicated higher concentrations of Ni and Zn in sugarcane, with maximum values of 41 mg kg{sup -1} and 118 mg kg{sup -1}, respectively and agricultural areas (41 mg kg{sup -1} and 127 mg kg{sup -1}, respectively). The trace element Sr was mainly enriched in urban soils with values of 400 mg kg{sup -1}. According to the results, the EDXRF method was successfully implemented, providing some chemical tracers for the quality assessment of tropical soils and sediments. (author)

  2. Enhancements and Health-Related Studies of Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Soliman, M.A.M.

    2012-01-01

    The work presented in this thesis covers two major points. One algorithm concerns with establishment of an accurate standardization method with multi-elemental capabilities and low workload suitable for NAA standardization at ETRR-2. The second one deals with constructing and developing an effective nondestructive technique for analysis of liquid samples based on NAA using (very) short-lived radionuclides. To achieve the first goal, attention has been directed toward implementation of the k 0 -method for calculation of the elements concentrations in the samples. The k 0 -method of NAA standardization has a considerable success as a method for accurate multi-elemental analysis with comparable low workload. The k 0 - method is based on the fact that the unknown sample is irradiated with only one standard element as comparator. To access the implementation of this method at ETRR-2, careful and complete characterization of the neutron flux parameters in the irradiation positions as well as the efficiency calibration of the γ-ray spectrometer must be carried out. The required neutron flux parameters are: the ratio of the thermal to epithermal neutron fluxes (f) and the deviation factor (α) of the epithermal neutron flux from the ideal 1/E law. The work presented in Chapter 4 shows the efficiency calibration curve of the γ ray spectrometer system which was obtained using standard radioactive point sources. Moreover, the f and α parameters were determined in some selected irradiation sites using sets of Zr-Au as neutron flux monitors. Due to different locations relative to the reactor core, the available neutron fluxes in the selected irradiation positions differ substantially, so that different irradiation demands can be satisfied. The reference materials coal NIST 1632c and IAEA-Soil 7 were analyzed for data validation and good agreement between the experimental values and the certified values was obtained. The obtained results have revealed that the k 0 -NAA

  3. Neutron activation analysis of phytotherapic obtained from medicinal plants; Analise por ativacao com neutrons de fitoterapicos obtidos de plantas medicinais

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Henrique S. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: hs_moreira@hotmail.com; Saiki, Mitiko; Vasconcellos, Marina B.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: mitiko@ipen.br; mbvascon@ipen.br

    2007-07-01

    This paper determines the inorganic constituents in phytotherapic samples for posterior study of the relationship existent among the concentrations of the found elements and the their possible therapeutical effects. The samples of phytotherapic pills (Centella asiatica, Ginkgo biloba and Ginseng) were analysed by using neutron activation analysis (NAA). The As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sc, Se and Zn samples were determined in the phytotherapics, The Centella asiatica presented the higher concentrations of Br, Co, Cr, Fe, K, La, Na, Rb, Sc, Se and Zn. In the sample of Ginko biloba, higher levels of As and Ca were found, while in the sample ol Ginseng the element As were not detected. The found results have shown the the NAA method is appropriated for analysing this type of materials due to his simplicity, multielemental capacity and quality of the results obtained. (author)

  4. Neutron activation analysis and provenance study of Tupiguarani Tradition pottery

    International Nuclear Information System (INIS)

    Faria, Gleikam Lopes de Oliveira; Menezes, Maria Angela de B.C.; Ribeiro, Loredana; Jacome, Camila

    2009-01-01

    Archaeology can fill the gap between ancient population and modern society elucidating the evidences found in archaeological sites. The fingerprint identified, that is the chemical composition of the ceramics, can help understanding this connection between the past and the present. The Tupiguarani Tradition vestiges found by archaeologists will be a way to know about the last two millennia of the Brazilian prehistory. This archaeological site is located along the coast of the Brazilian State of Espirito Santo, where the main evidence is a pretty ceramic with the occurrence of plastic and painted decoration. When the Portuguese settlers arrived in this region, in sixteenth century, several Missoes Jesuiticas (Jesuitical Missions) were built along the Brazilian coast. In spite of living within the Mission and been catechized, the Indians kept on producing traditional handicraft, as the decorated ceramic, however, they introduced European elements to the decoration. During the research expeditions made to the archaeological site of the Tupiguarani Tradition, many sherds were found. The identification and classification of ceramics through a multielemental chemistry analysis will be used to determine if they have the same origin. This paper shows the first elemental concentration results of the sherds collected from archaeological site determined at CDTN/CNEN, Belo Horizonte, Minas Gerais, using the TRIGA Mark I IPR-R1 nuclear reactor, applying the neutron activation technique, k 0 -method. (author)

  5. Analysis by neutronic activation of samples of a geologic formation of Cuba

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Pena Fortes, B.; Padilla Alvarez, R.; Llanes Castro, A.I.; Perez Zayas, G.; Hernandez Rivero, A.T.; Lopez Reyes, M. C.; Ribeiro Guevara, S.; Molina Insfran, J.

    1997-01-01

    The analysis by neutronic activation (AAN) is an analytical non destructive technique of high accuracy and sensibility. These advantages are very utilized in the determination of geological multielemental samples. In the job 22 elements are determined in 9 geological samples pertaining to the complex of dams of acid composition that includes the graphitic micaceous schist and the quartzites of the Canada Formation, developed fundamentally in the fasteners of the anticlinal Victoria (Yac. of Wolframio Lela, Island of the Youth, Cuba) The results obtained are of great importance for the evaluation of the potentiality of these rocks as fountains or of uranium adjusting and for the geologic prognostic of the region in study. The irradiation of the samples was carried out during three campaigns, in two occasions (October 1992 and November 1994) in the reactor of investigations of the ININ of Mexico, with a flow of thermic neutrons of 10a the 13 n.s -1 cm -2 and in an occasion in the nuclear reactor of the CAB (september 1994), with a flow of thermic neutrons of 6x 10 to the 12 n.s-1. The results were processed with the program ACTAM in the CEADEN. (S. Grainger) [es

  6. Assessment of metal and trace element concentrations in the Cananeia estuary, Brazil, by neutron activation and atomic absorption techniques

    International Nuclear Information System (INIS)

    Amorim, E.P.; Favaro, D.I.T.; Berbel, G.B.B.; Braga, E.S.

    2008-01-01

    Twenty six bottom sediment samples were collected from the Cananeia estuary in summer and winter of 2005. Multielemental analysis was carried out by instrumental neutron activation analysis. Total mercury was determined by cold vapor atomic absorption. As, Cr, Hg and Zn concentrations were compared to the Canadian oriented values (TEL and PEL). Sample points 4 and 9 presented higher concentration for most elements and As and Cr exceeded the TEL values. Organic matter (>10%) associated with siltic and clay sediments was observed. Climatic conditions, hydrodynamic and biogeochemical processes promote differences in seasonal concentrations of elements at some points, which contribute to special distributions. (author)

  7. X-ray fluorescence in Member States: Philippines. XRF activities at Analytical Measurements Research Group, Philippine Nuclear Research Institute

    International Nuclear Information System (INIS)

    Pabroa, Corazon B.; Castaneda, Soledad S.; Almoneda, Rosalina V.; Sucgang, Raymond J.; Racho, Joseph Michael D.; Morco, Ryan P.; Cuyco, Danilo; Jimenez, Gloria; Santos, Flora L.

    2008-01-01

    Full text: XRF analysis and activities of the Analytical Measurements Research (AMR) Group (see Fig.1) of the Philippine Nuclear Research Institute (PNRI) focus on both research and analytical services. Air pollution research, in particular source apportionment studies, requires multi-elemental data for a substantial number of samples. In the PNRI, energy-dispersive X-ray fluorescence (EDXRF) has been used as an effective tool for providing such multi-elemental data. With the latest acquisition of the Panalytical Epsilon 5 (E5) EDXRF system, the process of quantification has become easier and faster with the auto-quantify method. Other research involvements of the group are in the analysis of samples in relation to mineral explorations and the elemental characterization of water in support for isotope hydrology research. The AMR group, as part of its function to provide analytical services, offers qualitative or semi quantitative analysis of solid samples using the auto quantify method, quantitative analysis of environmental samples using the emission-transmission method and quantitative analysis of air particulate matter collected on filters. Telephone wire materials sold in junkshops (alleged to have been pilfered from installed telephone lines of a major telecommunications company in the country) and materials being assessed in relation to patent claims are other examples of samples submitted for analytical services. As mentioned, a useful feature of the E5 system is the use of the auto-quantify (AQ) method. Calibration lines used for this type of application are obtained using the fundamental parameter (FP) model. For AQ applications, accurate results are obtained for samples prepared as fused glass beads in which the whole matrix is known. However, only qualitative or semi quantitative analysis can be applied for other types of solid samples. The AQ method was adapted for the multi-elemental analysis of air particulates using the MicroMatter standards to set

  8. Multielemental accumulation and its intracellular distribution in tissues of some aquatic birds

    International Nuclear Information System (INIS)

    Nam, Dong-Ha; Anan, Yasumi; Ikemoto, Tokutaka; Tanabe, Shinsuke

    2005-01-01

    This study was aimed at determining multielemental concentration and its intracellular distribution in selected tissues of cormorant and waterfowl species. Non-essential elements such as Hg, Tl, Cd, Pb and V in tissues were generally consistent with those in ingested items, indicating the significance of food sources of non-essential metal accumulation in great cormorants and mallards. Great cormorants and four waterfowl species examined reflected natural background levels of toxic metals such as Cd, Hg and Pb as well as some essential elements, indicating no specific metal exposure from local sources. Most of Cu, Zn, Se, Rb, Ag, Cd, Cs, and Hg contents were present in the hepatocytosolic fraction, whereas a large percentage of V and Mo were present in insoluble fraction in great cormorant, mallard, and spot-billed duck. The major role of these subcelluar fractions in elemental regulation accounts for the high percentage contribution of each cellular fraction to the total metal contents. Cadmium and Cu are chiefly sequestered through binding to metallothioneins (MTs) of hepatocytosolic fraction in these three avian species. Both MTs and high-molecular-weight substance (HMWS) for Zn and low-molecular-weight substance (LMWS) for Rb were also involved in their sequestration in cytosolic fractions. Relatively different species-specific cytosolic substances were responsible for varying degrees of Ag, Mn, and Co accumulation. It is worth noting that these intracellular metal levels in birds are closely regulated by metal-associated cellular constituents. Therefore, risk assessment studies of metal accumulation in such wild birds should take intracellular metal distribution and specific cellular constituents into account

  9. Qualitative analysis of a powdered diamond sample by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Mabida, C.; Annegarn, H.J.; Renan, M.J.; Sellschop, J.P.F.

    The main purpose of this analysis was to determine whether nickel is present in diamond powder as a trace element. Particle induced X-ray emission (PIXE) showed unambiguously that nickel was present. Due to the convenience of PIXE in multielemental analysis, the investigations also include a number of other trace elements in the sample

  10. The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

    International Nuclear Information System (INIS)

    Barbos, D.; Paunoiu, C.; Mladin, M.; Cosma, C.

    2008-01-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φ scd = 1.10 6 n/cm 2 /s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates

  11. Descriptive, metallographic and chemical study of cooper-alloy points found at the grave of one member of the Sican elite, Lambayeque - Peru, using optical microscopy techniques and neutron activation analysis

    International Nuclear Information System (INIS)

    Vetter, L.; Carcedo, P.; Cutipa, S.; Montoya, E.

    1997-01-01

    This paper offers a description as well as physical and morphological analyses of 489 points found inside the grave of one of the elite members of Sican (900 - 1110 dC). A metallographic study of one of the points is also carried out, plus the multielemental-quantitative chemical analysis of twelve items from the same grave. In addition, four points of the same culture from the Museo Nacional de Arqueologia, Antropologia e Historia of Peru are also analyzed

  12. Multielemental analysis of agroindustrial by-products employed in animal feeding by INAA

    International Nuclear Information System (INIS)

    Teruya, C.M.; Armelin, M.J.A.; Saiki, M.

    2000-01-01

    Instrumental neutron activation analysis (INAA) with gamma-ray spectrometry was applied to determine As, Ca, Cd, Cl, Co, Cu, Cr, Fe, Hg, K, Mg, Mn, Mo, Na, Sb, Se and Zn in the Brazilian agroindustrial by-products. These materials are widely used in ruminant feeding. The results obtained were compared with requirement and maximum tolerable concentrations. The general conclusions from the data obtained were: (1) many by-products presented concentrations of some essential elements lower than the requirement concentrations, while in some samples the concentrations of Cr, Fe, Mg and Se exceeded by a little the maximum tolerable concentrations, (2) the elements As, Cd, Hg and Sb, generally considered toxic, showed concentrations lower than maximum tolerable values. (author)

  13. A critical review of nuclear activation techniques for the determination of trace elements in atmospheric aerosols, particulates and sludge samples

    International Nuclear Information System (INIS)

    Dams, R.

    1992-01-01

    Activation analysis is one of the major techniques for the determination of many minor and trace elements in a large variety of solid environmental and pollution samples, such as atmospheric aerosols, particulate emissions, fly ash, coal, incineration ash and sewage sludge, etc. Neutron activation analysis of total, inhalable or respirable airborne particulate matter collected on a filter or in a cascade impactor on some substrate, is very popular. By Instrumental Neutron Activation Analysis (INAA) up to 45 elements can be determined. The irradiation and counting procedures can be adapted to optimize the sensitivity for particular elements. The precision is largely governed by counting statistics and a high accuracy can be obtained after calibration with multi-elemental standards. Radiochemical Neutron Activation Analysis (RNAA) is applied only when extremely low limits of determination are required. Instrumental Photon Activation Analysis (IPAA) is complementary to INAA, since some elements of environmental interest can be determined which do not produce appropriate radionuclides by neutron irradiation. Charged Particle Activation Analysis (CPAA) is used in particular circumstances such as for certification purposes or coupled to radiochemical separations for extremely low concentrations. (author)

  14. Particle induced X-ray emission for quantitative trace-element analysis using the Eindhoven cyclotron

    International Nuclear Information System (INIS)

    Kivits, H.

    1980-01-01

    Development of a multi-elemental trace analysis technique using PIXE (Particle Induced X-ray Emission), was started almost five years ago at the Eindhoven University of Technology, in the Cyclotron Applications Group of the Physics Department. The aim of the work presented is to improve the quantitative aspects of trace-element analysis with PIXE, as well as versatility, speed and simplicity. (Auth.)

  15. Radiochemical neutron activation analysis of zirconium and zirconium-niobium alloys

    International Nuclear Information System (INIS)

    Tashimova, F.A.; Sadikov, I.I.; Salimov, M.

    2004-01-01

    Full text: Zirconium and zirconium-niobium alloys are used on nuclear technology, as fuel cladding of nuclear reactors. Their nuclear-physical, mechanical and thermophysical properties are influenced them matrix and impurity composition, therefore determination of matrix and impurity content of these materials is a very important task. Neutron activation analysis is one from multielemental and high sensible techniques that are widely applied in analysis of high purity materials. Investigation of nuclear-physical characteristics of zirconium has shown that instrumental variant NAA is unusable for analysis due to high radioactivity of a matrix. Therefore it is necessary carrying out radiochemical separation of impurity radionuclides from matrix. Study of the literature datum have shown, that zirconium and niobium are very well extracted from muriatic solution with 5% tributyl phosphineoxide (TBPO) solution in toluene and 0,75 M solution of di-2-ethyl hexyl phosphoric acid (HDEHP) in cyclohexanone. Investigation of these elements extraction in these systems has shown that more effective and selective separation of matrix radionuclides is achieved in HDEHP-3M HCI system. This system is also extracted and hafnium, witch is an accompanying element of zirconium and its high content prevented determination of other impurity elements in sample. Therefore we used extraction system HDEHP-3M HCl for analysis of zirconium and zirconium-niobium alloys in chromatographic variant. By measurement of distribution profile of a matrix and of elution curve of determined elements is established, that for effective separation of impurity and matrix radionuclides there is enough chromatographic column with diameter 1 cm and height of a sorbent layer 7 cm, thus volume of elute, necessary for complete elution of determinate elements is 35-40 ml. On the basis of the carried out researches the technique of radiochemical NAA of high purity zirconium and zirconium-niobium alloy, which allows to

  16. APPLICATION OF NEUTRON ACTIVATION ANALYSIS IN CHARACTERIZATION OF ENVIRONMENTAL SRM SAMPLES

    Directory of Open Access Journals (Sweden)

    Diah Dwiana Lestiani

    2010-06-01

    Full Text Available Neutron activation analysis (NAA is a nuclear technique that is excellent, multi-elemental, sensitive and has limit detection up to nanogram level. The application of NAA in analysis of Standard Reference Material (SRM National Institute of Standard Technology (NIST 1633b Coal Fly Ash and SRM NIST 1646a Estuarine Sediment was carried out for NAA laboratory inter-comparison program. The samples were distributed by Technology Centre for Nuclear Industry Material, National Nuclear Energy Agency as a coordinator of the inter-comparison program. The samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 1013 n.cm-2.s-1, and counted with HPGe spectrometry gamma detector. Several trace elements in these samples were detected. The concentration of Al, Mg, K, Na and Ti in SRM NIST 1633b were 15.11, 7.35, 2.09, 0.192 and 0.756% respectively and the concentration of As, Cr, Mn, Se, V, Sb, Co, Cs, La, Sc and Sm were 137.0, 195.6, 129.4, 9.61, 305.8, 5.45, 56.2, 11.18, 83.73, 41.1 and 19.13 mg/kg respectively. The analysis result in SRM NIST 1646a of the concentration of Al and Na were 2.15 and 0.70% and the concentration of As, Cr, Co, La and Sc were 5.75, 36.3, 4.58, 15.67 and 4.00 mg/kg respectively. These results analysis had relative bias and u-test ranged from 0.4-11.3% and 0.15-2.25. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA criteria was also applied. The result showed that NAA technique is applicable for the environmental samples analysis, and it also showed that the NAA laboratory in BATAN Bandung has a good performance.   Keywords: NAA, inter-comparison, estuarine sediment, coal fly ash, environmental samples

  17. Metal and trace element assessment of sediments from Guarapiranga reservoir, Sao Paulo State, by neutron activation analysis

    International Nuclear Information System (INIS)

    Guimaraes, Guilherme M.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.; Bevilacqua, Jose E.

    2009-01-01

    Guarapiranga Reservoir is extremely important due to the fact that it is one of the main water reservoirs for South America's largest city, Sao Paulo, Brazil. Guarapiranga Basin is located within the Metropolitan Region of Sao Paulo - RMSP, and occupies an area of approximately 630 km 2 , and the reservoir itself is located in the northern part of the basin occupying approximately 26 km 2 . This reservoir is characterized by environmental impacts from urban invasion, industrial and sewage wastes, all of which seriously affect its water quality. Due to its vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) regularly monitors the contamination levels of waters and once a year sediment samples. In order to better understand geochemical and environmental processes and their possible changes due to anthropogenic activities trace metals analyses and their distribution in sediments are commonly undertaken. The present study reports results concerning the distribution of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements in sediments from the Guarapiranga Reservoir. Multielementar analysis was carried out by instrumental neutron activation analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cr and Zn in the sediment samples were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and adopted by CETESB. (author)

  18. Application of cyclic activation to in vivo elemental analysis

    International Nuclear Information System (INIS)

    Spyrou, N.M.

    1984-01-01

    Experience over the past seven years with a prototype cyclic system, based on an oscillating 5Ci AmBe neutron source, suggests that multielemental in vivo analysis is possible and more specifically indicates that the determination of selenium and cadmium in liver may allow the examination of the interaction of the two elements at acceptable doses. Detection limits obtained for selenium and cadmium, in the same experiment but through different modes of detection i.e. the measurement of delayed gamma-rays from short-lived Se-77m (17.6 s) and prompt gamma-rays from Cd-114, in a cyclic sequence of irradiations, are 0.4 ppm and 6 ppm respectively, for a total irradiation period of 1800s and an equivalent dose to the irradiated region of 5mSv. The redesigning of the prototype system is being considered in order to decrease the detection limit of selenium to a value of 0.1 ppm or less and the effect of increasing the neutron flux tenfold is investigated. This could result in an improvement by a factor of 4 to 5 in detection, for the same dose. 36 references, 6 figures

  19. Handbook on simultaneous x-ray and γ-ray ion beam methods for fine particle analysis

    International Nuclear Information System (INIS)

    Cohen, D.D.

    2000-01-01

    Sampling, measurement, characterisation and source appointment of fine atmospheric particles has become increasingly important in recent times. This is due in part to the realisation that the fine particle pollution caused by anthropogenic activities plays a key role in certain aspects of human health, pollution transport and global climate change. This publication discusses accelerator based ion beam analysis (IBA) methods of particle induced X-ray emission (PIXE) and particle induced γ-ray emission (PIGE) as applied to aerosol analysis. These techniques are sensitive, multielemental, mainly non-destructive, require no sample preparation, have short analysis times and can be used to analyse hundreds of filter samples a day in batch processing with minimum operator interaction. The aspects discussed in the publication include: the basics of the techniques; spectrum analysis; system calibration and blank subtraction; quantification; sensitivity; measurement errors

  20. Neutron activation analysis of wheat samples

    International Nuclear Information System (INIS)

    Galinha, C.; Anawar, H.M.; Freitas, M.C.; Pacheco, A.M.G.; Almeida-Silva, M.; Coutinho, J.; Macas, B.; Almeida, A.S.

    2011-01-01

    The deficiency of essential micronutrients and excess of toxic metals in cereals, an important food items for human nutrition, can cause public health risk. Therefore, before their consumption and adoption of soil supplementation, concentrations of essential micronutrients and metals in cereals should be monitored. This study collected soil and two varieties of wheat samples-Triticum aestivum L. (Jordao/bread wheat), and Triticum durum L. (Marialva/durum wheat) from Elvas area, Portugal and analyzed concentrations of As, Cr, Co, Fe, K, Na, Rb and Zn using Instrumental Neutron Activation Analysis (INAA) to focus on the risk of adverse public health issues. The low variability and moderate concentrations of metals in soils indicated a lower significant effect of environmental input on metal concentrations in agricultural soils. The Cr and Fe concentrations in soils that ranged from 93-117 and 26,400-31,300 mg/kg, respectively, were relatively high, but Zn concentration was very low (below detection limit Fe>Na>Zn>Cr>Rb>As>Co. Concentrations of As, Co and Cr in root, straw and spike of both varieties were higher than the permissible limits with exception of a few samples. The concentrations of Zn in root, straw and spike were relatively low (4-30 mg/kg) indicating the deficiency of an essential micronutrient Zn in wheat cultivated in Portugal. The elemental transfer from soil to plant decreases with increasing growth of the plant. The concentrations of various metals in different parts of wheat followed the order: Root>Straw>Spike. A few root, straw and spike samples showed enrichment of metals, but the majority of the samples showed no enrichment. Potassium is enriched in all samples of root, straw and spike for both varieties of wheat. Relatively to the seed used for cultivation, Jordao presented higher transfer coefficients than Marialva, in particular for Co, Fe, and Na. The Jordao and Marialva cultivars accumulated not statistically significant different

  1. Application of PIXE and NAA methods to the analysis of lichens from Antarctica

    International Nuclear Information System (INIS)

    Badica, T.; Popescu, I.V.; Cojocaru, V.; Olariu, A.; Stefanescu, I.; Petre, M.; Pantelica, A.; Salajan, M.; Balabanski, D.; Gourev, V.; Chipev, N.

    1999-01-01

    Proton Induced X-Ray Emission (PIXE) and Neutron Activation Analysis (NAA) have emerged as powerful analytical techniques for the detection of trace elements in environmental samples, especially in the antarctic environmental, because of its multielemental character and high sensitivity. This methods of analysis have been used to find the concentration of trace elements in the lichens collected from Antarctica zone. Trace contents of elements like As, Au, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Cu, Eu, Fe, Hf, Hg, K, La, Mn, Na, Ni, Rb, S, Sb, Se, Sm, Sr, Ti, Tb, Th, U, Zn and Yb have been determined. Preliminary data suggest that nuclear methods may be useful in elucidating element absorption and transport mechanisms in lichens as a sensitive indicator of the species growing in the environmental polluted sites. (authors)

  2. The potentials and limitations of using neutron activation analysis data on human hair as a forensic evidence

    International Nuclear Information System (INIS)

    Pillay, K.K.S.; Kuis, R.L.

    1978-01-01

    A survey of hair samples from a group of 300 vounteers, involving nearly 12 000 elemental analyses, indicates that while neutron-activation-analysis data have distinct potentials to develop useful forensic evidence, there are several limitations to its routine applications. The multi-elemental analyses of hair-wash samples were done using multiple neutron irradiation and high resolution gamma ray spectrometry. All neutron irradiations were performed in the Penn State TRIGA Reactor at a thermal neutron flux of approximately 10 13 nxcm -2 xs -1 . The gamma-ray spectrometric measurements utilized a 40 cm 3 high resolution Ge(Li) detector. This detector, in association with a software oriented programmable multichannel analyzer with a 12 K core size, was used for gamma ray spectrometric measurements. The data were recorded on computer-compatible magnetic tape. The quantitative measurements of only 22 elements were reported from both the hair samples and the ''hair-wash''. These elements are Ti, I, Br, Mn, Cu, V, Cl, Al, Na, Ca, Se, Hg, Cr, Au, Sb, Ag, Sc, Zn, Co, Fe, and La. In expressing the analytical results of ''hair-wash'' samples, the weight of hair from which the hair-wash originated was used to calculate the results in terms of the weight of hair. (T.G.)

  3. Multielement determination in Tillandsia by INAA

    International Nuclear Information System (INIS)

    Capannesi, G.; Cecchi, A.; Cecchi-Fiordi, A.

    1987-01-01

    Instrumental neutron activation analysis was employed to measure 43 elements, including some macroconstituents, in the leaves of some species of the epiphytic genus Tillandsia (Bromeliaceae). The results, confirming the oligotrophyc nature of the genus, are briefly discussed with regard to a possible role as multielemental environmental monitors. (author) 7 refs

  4. Metal and trace element sediment assessment from Salto Grande reservoir, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Walace A.A., E-mail: walace@usp.br [Setor de Analises Toxicologicas. CETESB, Sao Paulo, SP (Brazil); Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao com Neutrons

    2011-07-01

    The Salto Grande Reservoir is used for electric generation, irrigation, fish farming, recreation and water supply for the region's cities. The reservoir belongs to the city of Americana, located in on the eastern region of Sao Paulo State, Brazil. It belongs to the Piracicaba River Hydrographic Basin, the second most important economic and populated region and one of the most polluted areas in the State. This basin is located in a highly industrialized and agricultural region. Due to urban, industrial and agricultural activities as well as sewage wastes the water and sediments of this reservoir and surroundings are extremely contaminated, mainly by metals, according to CETESB (Environmental Control Agency of the Sao Paulo State). In order to obtain better information about its sediment contamination the present study reports results of the concentration of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Se, Ta, Th, U, Zn and rare earth (Ce, Eu, La, Lu, Nd, Sc, Sm, Tb and Yb)) elements in sediments and Cd, Cr, Cu, Ni and Pb concentration in sediments and water from the Salto Grande Reservoir. Multielementar analysis was carried out by Instrumental Neutron Activation Analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cd, Cr, Cu, Pb, Ni and Zn were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL) and adopted by CETESB, (author)

  5. Metal and trace element sediment assessment from Salto Grande reservoir, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Soares, Walace A.A.; Favaro, Deborah I.T.

    2011-01-01

    The Salto Grande Reservoir is used for electric generation, irrigation, fish farming, recreation and water supply for the region's cities. The reservoir belongs to the city of Americana, located in on the eastern region of Sao Paulo State, Brazil. It belongs to the Piracicaba River Hydrographic Basin, the second most important economic and populated region and one of the most polluted areas in the State. This basin is located in a highly industrialized and agricultural region. Due to urban, industrial and agricultural activities as well as sewage wastes the water and sediments of this reservoir and surroundings are extremely contaminated, mainly by metals, according to CETESB (Environmental Control Agency of the Sao Paulo State). In order to obtain better information about its sediment contamination the present study reports results of the concentration of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Se, Ta, Th, U, Zn and rare earth (Ce, Eu, La, Lu, Nd, Sc, Sm, Tb and Yb)) elements in sediments and Cd, Cr, Cu, Ni and Pb concentration in sediments and water from the Salto Grande Reservoir. Multielementar analysis was carried out by Instrumental Neutron Activation Analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cd, Cr, Cu, Pb, Ni and Zn were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL) and adopted by CETESB, (author)

  6. Total CMB analysis of streaker aerosol samples by PIXE, PIGE, beta- and optical-absorption analyses

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Przybylowicz, W.J.

    1993-01-01

    Multielemental analyses of aerosol samples are widely used in air pollution receptor modelling. Specifically, the chemical mass balance (CMB) model has become a powerful tool in urban air quality studies. Input data required for the CMB includes not only the traditional X-ray fluorescence (and hence PIXE) detected elements, but also total mass, organic and inorganic carbon, and other light elements including Mg, Na and F. The circular streaker sampler, in combination with PIXE analysis, has developed into a powerful tool for obtaining time-resolved, multielemental aerosol data. However, application in CMB modelling has been limited by the absence of total mass and complementary light element data. This study reports on progress in using techniques complementary to PIXE to obtain additional data from circular streaker samples, maintaining the nondestructive, instrumental approach inherent in PIXE: Beta-gauging using a 147 Pm source for total mass; optical absorption for inorganic carbon; and PIGE to measure the lighter elements. (orig.)

  7. Multi-elemental characterization of Cuban natural zeolites

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Herrera Peraza, E.F.

    1996-01-01

    Concentrations of 38 elements in samples from four important Cuban zeolite bed have beam obtained by Instrumental Neutron Activation (INAA) and X-Ray Fluorescence Analysis (XRFA). In comparison with other analytical techniques good agreement was achieved. The concentration values of minor element Ba, Sr, Zn, and Mn, and 25 trace element (including 9 REE) are at the first time reported in Cuban zeolite. It is important for the zeolite evaluation in different industrial uses

  8. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    Gruber, X.; Kregsamer, P.; Wobrauschek, P.; Streli, C.

    2006-01-01

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  9. Total-reflection X-ray fluorescence analysis of Austrian wine

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, X. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Kregsamer, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Wobrauschek, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Streli, C. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria)]. E-mail: streli@ati.ac.at

    2006-11-15

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 {mu}l of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines.

  10. Use of species of the genus Tillandsia as bio monitors of the atmospheric contamination using radiochemical analysis

    International Nuclear Information System (INIS)

    Alonso, M. T.; Wilkinson, M. V.; Marques, R.

    2000-01-01

    The use of epiphytic plants as bio monitors of environmental pollution is studied in this paper. Species of the genus Tillandsia were selected to make studies, on the one hand, using the Neutron Activation Analysis in order to make multielemental analysis to detect possible pollutants. Optimum conditions of preparation and treatment of the samples were determined to verify the elemental uptake in plant tissues. On the other hand, some studies were carried out to investigate the uptake (translocation) of possible pollutants by using radiotracers. With this aim, a conditioned area (glove box) has been developed in order to reproduce the environment of these plants. This glove box was used for studies with radiotracers. The results of the experiments with Hg as radiotracer are presented in this paper. (author)

  11. The application of nuclear and nuclear-related techniques for environmental pollution studies in Vietnam

    International Nuclear Information System (INIS)

    Nguyen Mong Sinh

    1992-01-01

    The applicability of neutron activation analysis, X-ray fluorescence and other related techniques to environmental samples from Viet Nam has been investigated. Results show that multielemental analysis of environmental samples and the determination of heavy metal pollution in the environment is best performed by a combination of techniques. Preliminary results of studying the environmental pollution associated with solid wastes are reported. 4 refs, 5 figs, 17 tabs

  12. Performance evaluation of the ORNL multi-elemental XRF analysis algorithms

    Energy Technology Data Exchange (ETDEWEB)

    McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Hybrid K-Edge Densitometer (HKED) systems integrate both K-Edge Densitometry (KED) and X-Ray Fluorescence (XRF) analyses to provide accurate rapid, assay results of the uranium and plutonium content of dissolver solution samples from nuclear fuel reprocessing facilities. Introduced for international safeguards applications in the late 1980s, the XRF component of the hybrid analyses is limited to quantification of U and Pu over a narrow range of U:Pu concentration ratios in the vicinity of ≈100. The analysis was further limited regarding the presence of minor actinide components where only a single minor actinide (typically Am) is included in the analysis and then only treated as an interference. The evolving nuclear fuel cycle has created the need to assay more complex dissolver solutions where uranium may no longer be the dominant actinide in the solution and the concentrations of the so called minor actinides (e.g., Th, Np, Am, and Cm) are sufficiently high that they can no longer be treated as impurities and ignored. Extension of the traditional HKED Region of Interest (ROI) based analysis to include these additional actinides is not possible due to the increased complexity of the XRF spectra. Oak Ridge National Laboratory (ORNL) has developed a spectral fitting approach to the HKED XRF measurement with an enhanced algorithm set to accommodate these complex XRF spectra. This report provides a summary of the spectral fitting methodology and examines the performance of these algorithms using data obtained from the ORNL HKED system, as well as data provided by the International Atomic Energy Agency (IAEA) on actual dissolver solutions.

  13. Characteristic Elemental Composition of Oil Pigments using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Kim, Young Jin; Lim, Sung Jin; Song, Yu Na; Kim, Ken

    2009-01-01

    The principal aim of this study is to identify the applicability of instrumental neutron activation analysis as a non-destructive examination tool for the quantitative composition analysis associated with authentication, restoration, and conservation of art objects in the field of cultural heritage. Generally, the chemical composition of pigments are associated with the colors such as white, yellow, orange, red, green, blue and black, and it varies with raw materials of pigments. According to the colors of a different pigments, chemical compositions are as follows; for example, white pigments were used for a mixture of Pb(CO 3 ) 2 , PbSO 4 , PbO, Pb(OH) 2 , ZnO, ZnS, TiO 2 , BaSO 4 , CaCO 3 , Al 2 O 3 , As 2 S 3 , etc.; black pigments were series of carbon black, borne ash, MnO+Mn 2 O 3 , etc.; red pigments were Fe 2 O 3 , Pb 3 O 4 , HgS, PbMo 4 , CdS+CdSe, etc.; brown and yellow pigments were PbCrO 4 , ZnCrO 4 , CdS-ZnS, K 3 [Co(NO 2 ) 6 ], Pb(SbO 3 ) 2 , C 19 H 16 O 11 Mg, SrCrO 4 , etc.; green pigments were Cr 2 O 3 , Cr 2 O(OH) 4 , Cu(C 2 H 3 O 2 )-2Cu(OH) 2 ), Cr 2 O 3 -Al 2 O 3 -CoO, etc.; blue pigments were Fe 4 [Fe(CN) 6 ] 3 , CoO-Al 2 O 3 , Na 8 - 10 Al 6 Si 6 O 24 S 2-4 , etc. This first step is to obtain quantitative data on the concentrations of major, minor and trace elements in oil pigments and to explain pigment sources by statistical treatment as reported in many literatures. The determination of major, minor and micro elements in the subject materials are essential in many fields of basic science and technology as well as commercial and industrial fields. In particular, direct analysis of a sample offers a more effective investigation method in these fields. Instrumental neutron activation analysis (INAA) has an inherent advantage of being a non-destructive, simultaneously multi-elemental analysis with high accuracy and sensitivity. In order to characterize the elemental contents of art objects, the quantitative analysis of oil pigment series was

  14. Neutron activation analysis of wheat samples

    Energy Technology Data Exchange (ETDEWEB)

    Galinha, C. [CERENA-IST, Technical University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal); Instituto Tecnoclogico e Nuclear, URSN, E.N. 10, 2686-953 Sacavem (Portugal); Anawar, H.M. [Instituto Tecnoclogico e Nuclear, URSN, E.N. 10, 2686-953 Sacavem (Portugal); Freitas, M.C., E-mail: cfreitas@itn.pt [Instituto Tecnoclogico e Nuclear, URSN, E.N. 10, 2686-953 Sacavem (Portugal); Pacheco, A.M.G. [CERENA-IST, Technical University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal); Almeida-Silva, M. [Instituto Tecnoclogico e Nuclear, URSN, E.N. 10, 2686-953 Sacavem (Portugal); Coutinho, J.; Macas, B.; Almeida, A.S. [INRB/INIA-Elvas, National Institute of Biological Resources, Est. Gil Vaz, 7350-228 Elvas (Portugal)

    2011-11-15

    The deficiency of essential micronutrients and excess of toxic metals in cereals, an important food items for human nutrition, can cause public health risk. Therefore, before their consumption and adoption of soil supplementation, concentrations of essential micronutrients and metals in cereals should be monitored. This study collected soil and two varieties of wheat samples-Triticum aestivum L. (Jordao/bread wheat), and Triticum durum L. (Marialva/durum wheat) from Elvas area, Portugal and analyzed concentrations of As, Cr, Co, Fe, K, Na, Rb and Zn using Instrumental Neutron Activation Analysis (INAA) to focus on the risk of adverse public health issues. The low variability and moderate concentrations of metals in soils indicated a lower significant effect of environmental input on metal concentrations in agricultural soils. The Cr and Fe concentrations in soils that ranged from 93-117 and 26,400-31,300 mg/kg, respectively, were relatively high, but Zn concentration was very low (below detection limit <22 mg/kg) indicating that soils should be supplemented with Zn during cultivation. The concentrations of metals in roots and straw of both varieties of wheat decreased in the order of K>Fe>Na>Zn>Cr>Rb>As>Co. Concentrations of As, Co and Cr in root, straw and spike of both varieties were higher than the permissible limits with exception of a few samples. The concentrations of Zn in root, straw and spike were relatively low (4-30 mg/kg) indicating the deficiency of an essential micronutrient Zn in wheat cultivated in Portugal. The elemental transfer from soil to plant decreases with increasing growth of the plant. The concentrations of various metals in different parts of wheat followed the order: Root>Straw>Spike. A few root, straw and spike samples showed enrichment of metals, but the majority of the samples showed no enrichment. Potassium is enriched in all samples of root, straw and spike for both varieties of wheat. Relatively to the seed used for cultivation

  15. PIXE analysis of tree leaves as a possible comparative integral monitor of particulates in urban areas

    International Nuclear Information System (INIS)

    Zucchiati, A.; Annegarm, H.J.; Chisci, R.

    1988-01-01

    The possibility of obtaing integral comparative data for particulate distribution in urban areas from PIXE analysis of tree leaves is discussed in relation to the leaf gross anatomy, to the diffusion of selected tree species in such areas and to the implementation of experimental techniques necessary to make PIXE analysis effective. Multielemental scans were performed on a small set samples; results are compared to PIXE analysis of typical urban aerosols. The validity of the method and the criteria for yearly relative comparisons of different areas are discissed

  16. Neutron activation analysis of alternative phosphate rocks used in animal nutrition; Analise por ativacao neutronica por fontes alternativas de fosforo para a nutricao animal

    Energy Technology Data Exchange (ETDEWEB)

    Canella, Artur A.; Ferreira, Walter M. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Escola de Veterinaria]. E-mail: avelara@ufmg.br; Menezes, Maria Angela de B.C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)]. E-mail: menezes@cdtn.br

    2005-07-01

    Since 1980's, Bovine Sponghiform Encephalophaty has insidiously created a fierce battleground between farmers, scientists, environmentalists and consumers. The use of meat and bone meals is currently prohibited in ruminant feeds throughout the world. Some inorganic sources offer the combination of high phosphorus content and acceptable animal digestibility make them options as supplemental phosphorus, for instance phosphate rocks, general term applied to minerals valued chiefly for their phosphorus content. However, phosphate rocks are long been known containing hazardous elements, make them sometimes unsuitable for animal nutrition. Neutron Activation Analysis has been supportive to the mineral evaluation of alternative phosphate rocks. This evaluation is subject of on-going doctoral thesis which has been carried-out by the main author. The NAA method has been very efficient due to its highly sensitive and multi-elemental nature. In this paper results of Vanadium content from three different phosphate rocks are presented. Their values have been pointed out that Brazilian phosphate rocks present hazardous elements at the same levels of phosphate rocks from some countries of Africa, North America and Middle East, data from our study (Brazilian data) and FAO - Food and Agriculture Organization (others countries). (author)

  17. Elemental analysis of oum er rbia moroccan river-water Using icp-aes and chromatography

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; Labraimi, M.; Moutte, J.; Bilal, E.

    2001-01-01

    The analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 22 elements has been performed utilizing ICP-AES and chromatography methods. MPS samples were dissolved in nitric acid. The element analyzed are : Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Br, Ba and Pb. The detection limits are sufficient for most of the elements to be determined. Results were assessed for the accuracy by the analysis of a multi-elemental standard. The results for most of the elements obtained were accurate to about 2-15%. The objective of the analysis were to determine the geochemical areas on this river, to explain the mechanisms of sediment transport and nevertheless, to assess the pollution of the river by human activities. 48 samples were collected along the river, between its source in meddle atlas and the Atlantic ocean at Azemour city

  18. Activation analysis at the Institute of nuclear physics of Uzbekistan Academy of sciences

    International Nuclear Information System (INIS)

    Aripov, G.A.; Bakiev, S.A.; Danilova, E.A.; Khaydarov, R.A.; Khatamov, Sh.Kh.; Khudaybergenov, U.Kh.; Kist, A.A.; Mukhammedov, S.M.; Mukhamedshina, N.M.; Pulatov, D.D.; Rakhmanov, J.; Sadikov, I.I.; Salikhbaev, U.S.; Sattarov, G.S.; Tillaev, T.S.; Usmanova, M.M.; Yuldashev, B.S.; Zhuk, L.I.

    2006-01-01

    Full text: One of the main scientific directions of the Institute of Nuclear Physics is the nuclear analytical technique, especially, neutron activation analysis. The main objects of analysis are rocks, ores, water, pure materials and alloys, soil, fertilizers, plants, foods, biological liquids and tissues, etc. There were elaborated and are in use multielemental analytical techniques for these samples. Using cyclotron (accelerated charged particles) the analytical techniques have been elaborated especially for high sensitive determination of oxygen in various materials. Using neutron generator rapid analytical techniques were elaborated for determination of oxygen and other elements. Technique of determination of distribution of hydrogen nuclides is used in study material for thermal nuclear reactors. High sensitive and productive technique of determination of gold and accompanying elements were used in study of geochemistry of gold and gold prospecting. For geology and mining industry the automated system has been created for determination of gold and 10 additional elements with the capacity of 70,000 samples of large grain size of ores and rocks per year. For using of activation analysis in the field or at factories transportable system with nuclide neutron sources ( 252 Cf and 124 Sb-Be) has been constructed. There were also elaborated the techniques of prompt gamma analysis for geology and mining industry. If necessary to increase the sensitivity of determination there were elaborated techniques with radiochemical separation. These methods were used for studying of geochemistry of elements of Pt group, lanthanides, gold and silver. As a result there were elaborated processes of gold and silver extraction from wastes and Re, Sc, Te by production. These results allowed to create joint laboratories at gold producing factory, uranium producing factory, nonferrous metals factory, Ministry of geology, Ministry of internal affairs etc. Studies of human liquids and

  19. Air pollution biomonitoring in Argentina, application of neutron activation analysis to the study of biomonitors

    International Nuclear Information System (INIS)

    Pignata, M.L.; Pla, R.R.

    1999-01-01

    The assessment of baseline levels of atmospheric pollutants and the identification of polluted areas is a complex problem, as pollutant contents at a certain geographical location is usually a combination of contributions from various diverse sources, including long-range transport. Elemental chemical characterization of atmospheric pollutants is thus of great importance and Neutron Activation Analysis has proved to be a powerful technique for multielemental determination of trace elements in biomonitors and aerosols. The general objective of this project is to study the use of biomonitors, specially lichens, for evaluating pollutant levels over a wide geographic area of Argentina and for establishing baseline values and assessing time trends. Two lichen species (Usnea sp. and Ramalina ecklonii (Spreng.) Mey. and Flot) have been identified as suitable monitors of air pollution, with potential regional application at the central area of the country (province of Cordoba) and pilot studies have been initiated to test the practicability of sampling and sample collection. An area of approximately 40,000 km 2 will be covered by a sampling network, using in situ growing lichens. The distribution maps for the two selected species are already drawn and sampling of local soils will also be conducted. Current efforts at the Neutron Activation Analysis laboratory are put on assessing, for the selected lichen species, the influence of sample preparation methods on trace element concentrations. The use of other analytical techniques will allow the evaluation of the bioindicator chemical response and its relationship to different atmospheric quality levels. Source identification and apportionment will be done by statistical fingerprinting of the elemental concentrations, as sources of pollution are characterized by being composed of different mixtures of elements in different proportions. In this way and as a long-term objective, regional maps will be drawn showing the

  20. Characteristic Elemental Composition of Oil Pigments using Instrumental Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Kim, Young Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, Sung Jin; Song, Yu Na; Kim, Ken [National Museum of Contemporary Art, Gwacheon (Korea, Republic of)

    2009-10-15

    The principal aim of this study is to identify the applicability of instrumental neutron activation analysis as a non-destructive examination tool for the quantitative composition analysis associated with authentication, restoration, and conservation of art objects in the field of cultural heritage. Generally, the chemical composition of pigments are associated with the colors such as white, yellow, orange, red, green, blue and black, and it varies with raw materials of pigments. According to the colors of a different pigments, chemical compositions are as follows; for example, white pigments were used for a mixture of Pb(CO{sub 3}){sub 2}, PbSO{sub 4}, PbO, Pb(OH){sub 2}, ZnO, ZnS, TiO{sub 2}, BaSO{sub 4}, CaCO{sub 3}, Al{sub 2}O{sub 3}, As{sub 2}S{sub 3}, etc.; black pigments were series of carbon black, borne ash, MnO+Mn{sub 2}O{sub 3}, etc.; red pigments were Fe{sub 2}O{sub 3}, Pb{sub 3}O{sub 4}, HgS, PbMo{sub 4}, CdS+CdSe, etc.; brown and yellow pigments were PbCrO{sub 4}, ZnCrO{sub 4}, CdS-ZnS, K{sub 3}[Co(NO{sub 2}){sub 6}], Pb(SbO{sub 3}){sub 2}, C{sub 19}H{sub 16}O{sub 11}Mg, SrCrO{sub 4}, etc.; green pigments were Cr{sub 2}O{sub 3}, Cr{sub 2}O(OH){sub 4}, Cu(C{sub 2}H{sub 3}O{sub 2})-2Cu(OH){sub 2}), Cr{sub 2}O{sub 3}-Al{sub 2}O{sub 3}-CoO, etc.; blue pigments were Fe{sub 4}[Fe(CN){sub 6}]{sub 3}, CoO-Al{sub 2}O{sub 3}, Na{sub 8}-{sub 10}Al{sub 6}Si{sub 6}O{sub 24}S{sub 2-4}, etc. This first step is to obtain quantitative data on the concentrations of major, minor and trace elements in oil pigments and to explain pigment sources by statistical treatment as reported in many literatures. The determination of major, minor and micro elements in the subject materials are essential in many fields of basic science and technology as well as commercial and industrial fields. In particular, direct analysis of a sample offers a more effective investigation method in these fields. Instrumental neutron activation analysis (INAA) has an inherent advantage of being a

  1. Multi-elemental analysis of marine sediments of Manila Bay using x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Rosales, Colleen Marciel Fontelera

    2011-04-01

    An analysis of the marine sediments of Manila Bay was done by employing X-ray fluorescence spectrometry. The general trends observed in sediments are increasing (Ca and Sr), decreasing (Zr), or constant (Cl, Na, S, K) with respect to depth, sometimes, no trend can be observed. These trends are further explained by correlations present among these elements, plus all the other elements. The two X RF data analysis methods Auto Quantify and AXIL were also compared on the basis of the correlation plot obtained. AutoQuantify gave clearer correlations; thus, results from this method were used for constructing correlation plots. Correlations using Microsoft Excel and Stat graphics Centurion X V show that there are naturally occurring [lithogenic (Si, Ti, Al, Mg, Rb, Zn and Fe), biogenic (Ca, Mg), and conservative (Na, Cl)] and non-naturally occurring [mostly anthropogenic, brought to the bodies of water by aeolian or fluvial input (heavy metals Pb-Cu-Zn and Ni-Cr)] correlation present in the sediments. Moreover, pairs of elements that may coexist in a source and not coexist in another (Cr and Mg, Cr and Ni) have also been observed. The heavy metal enrichment was attributed to the burning of fossil fuels, iron and steel manufacturing (present in Valenzuela-Bulacan area), ferry and fishing services and other industrialization activities present in Manila Bay. Marine organisms are affected by the presence of these heavy metals by means of bioaccumulations, and may later on affect humans because of trophic transfer and bio magnification. (author)

  2. Is activation analysis still active?

    International Nuclear Information System (INIS)

    Chai Zhifang

    2001-01-01

    This paper reviews some aspects of neutron activation analysis (NAA), covering instrumental neutron activation analysis (INAA), k 0 method, prompt gamma-ray neutron activation analysis (PGNAA), radiochemical neutron activation analysis (RNAA) and molecular activation analysis (MAA). The comparison of neutron activation analysis with other analytical techniques are also made. (author)

  3. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  4. Major and trace elements assessment in sediment samples from Rio Grande Reservoir, by neutron activation analysis

    International Nuclear Information System (INIS)

    Franklin, Robson L.; Ferreira, Francisco J.; Favaro, Deborah I.T.; Bevilacqua, Jose Eduardo

    2009-01-01

    The Rio Grande Reservoir, Southeast of the Sao Paulo Metropolitan Area (SPMA) supplies water for four counties (Sao Bernardo do Campo, Sao Caetano do Sul, Santo Andre and Diadema). It has been seriously affected by urban expansion, due to chaotic urban occupation and improper use of the surrounding areas. In this study bottom sediment samples were collected, by using a Van Veen sampler, during the dry and rainy seasons. Four sampling points were defined by using GPS and are located at the mouth of the Rio Grande and Ribeirao Pires Rivers, in the middle of the reservoir and near the catchment point of the water supply. The sediment samples were submitted to instrumental neutron activation analysis (INAA) and the following elements were determined: As, Ba, Br, Co, Cr, Cs, Rb, Sb, Sc, Se, Ta, Th, U e Zn and the rare earth elements Ce, Eu, La, Lu, Nd, Sm, Tb, Yb. Short irradiation was also performed for total Hg determination by NAA using 197 Hg radioisotope. This was possible due to the high Hg concentration levels in these sediments. The methodology validation was carried out by certified reference material analyses. The results obtained for multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values obtained for As and metals Cr, Hg and Zn in the sediment samples were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and adopted by CETESB. (author)

  5. Use of species of the genus Tillandsia as bio monitors of the atmospheric contamination using radiochemical analysis; Utilizacion de especies del genero Tillandsia como biomonitores de la contaminacion atmosferica utilizando tecnicas radioquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, M T; Wilkinson, M V; Marques, R [Buenos Aires Univ. (Argentina). Dept. de Quimica Inorganica, Analitica y Quimica Fisica; Castro, M A [Buenos Aires Univ. (Argentina). Dept. de Ciencias Biologicas; Di Risio, C [Buenos Aires Univ. (Argentina)

    2000-07-01

    The use of epiphytic plants as bio monitors of environmental pollution is studied in this paper. Species of the genus Tillandsia were selected to make studies, on the one hand, using the Neutron Activation Analysis in order to make multielemental analysis to detect possible pollutants. Optimum conditions of preparation and treatment of the samples were determined to verify the elemental uptake in plant tissues. On the other hand, some studies were carried out to investigate the uptake (translocation) of possible pollutants by using radiotracers. With this aim, a conditioned area (glove box) has been developed in order to reproduce the environment of these plants. This glove box was used for studies with radiotracers. The results of the experiments with Hg as radiotracer are presented in this paper. (author)

  6. Uses of reactor neutrons for studying the microcomposition of materials

    International Nuclear Information System (INIS)

    Jervis, R.E.

    1993-01-01

    Reactor neutrons constitute excellents 'probes' for exploring and measuring a wide range both of minor and trace constituents in solids and liquids with high sensitivity because of their transparency in materials. Nondestructive neutron prompt-gamma analysis (PGA) utilizing either cold or thermal neutrons, such as at JRR-3M, is compared and contrasted to the more common (delayed) instrumental neutron activation analysis (INAA) and epithermal NAA. Clearly PGA offers high sensitivity for selected elements: B, H, Cd and REE's in suitable matrices, and is therefore, complementary to INAA which is not as useful for them, or for Ni, Sn, Fe, C or N. Recent INAA applications in our laboratory that demonstrate some of the uniqueness of neutron methods include use of epithermal neutrons for small biological specimens to measure Cd, K, As, Zn and, multielemental INAA for environmental pollution studies. The latter involves large data sets of multielemental concentrations which are subjected to statistical multivariant factor analysis to reveal unknown or unsuspected quantitative relationships among groups of trace constituents. These patterns, or 'factors' are shown to be uniquely related to pollution sources and can be utilized to compute the relative source contributions at a given receptor site. (author)

  7. Elemental analysis of Oum er Rbia Moroccan river-water using TXRF

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; El Hamdaoui, A.; Labraimi, M.

    2000-01-01

    The x-ray fluorescence analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 17 elements has been performed utilizing the energy dispersive x-ray fluorescence spectrometer and total reflection excitation. SPM samples were dissolved in nitric acid. For all samples direct measurements are feasible by spiking a few ml of the sample with Ga as internal standard element, and drying an aliquot of 20 μl on a quartz glass carrier. The detection limits of 10 to 20 ppb are sufficient for most of the elements to be determined. Results were assessed for accuracy by the analysis of the 15474 ICP multi-elemental standard I. Some results were also compared with AAS and ICP-AES. The results for most of the elements obtained by TXRF were accurate to about 2-15 %. The objectives of the analysis were to determine the geo-chemical areas on this river, to explain the mechanism of sediment transport and to assess the pollution of the river by human activities. 36 samples had been collected along the river between its source in Middle Atlas and the Atlantic ocean at Azemour city. (author)

  8. Multielemental analysis of ayurvedic medicines by INAA

    International Nuclear Information System (INIS)

    Garg, A.N.

    2006-01-01

    A large number of commonly used medicinal herbs, herbal formulations and bhasmas have been analyzed for minor and trace elements using short and long neutron irradiation in nuclear reactor followed by high resolution gamma ray spectrometry. Up to 30 elements have been determined. In addition Ni, Cd and Pb contents were determined by AAS. Elemental profiles of species derived from different geographical locations were found similar though some contents were found widely different depending on the geo environmental factors. Elemental contents have been attributed to the therapeutic importance of the herbal medicines. A review of our work is presented. (author)

  9. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  10. Analysis of light elements by PIGE

    International Nuclear Information System (INIS)

    Kim, Y. S.; Choi, H. W.; Kim, D. K.; Woo, H. J.; Kim, N. B.; Park, K. S.

    2000-01-01

    The PIGE (Proton Induced Gamma ray Emission) method was applied for the measurement of light elements Li - K. A test measurement has been performed for geological, biological, environmental and material samples by using a standard sample for each element. The measurement was performed for the two proton energies of 2.4 and 3.4 MeV, and 3.4MeV was found to yield better result for multielemental analysis. The result shows a fair agreement within 15% for all elements with standard values. The detection limits of Li, B, F and Na are less than 100 ppm, while those of the other elements are from a few hundred ppm to a few percents. (author)

  11. Trace metals analysis in estuarine and seawater by ICP-MS using on line preconcentration and matrix elimination with chelating resin.

    Science.gov (United States)

    Nicolaı, M; Rosin, C; Tousset, N; Nicolai, Y

    1999-09-13

    The main difficulties of trace metals analysis in estuarine and seawater stem from their very low concentration (mug/l to sub-mug/l), and, by contrast, the high salt content (up to 38 g/l in the Mediterranean Sea). ICP-MS allows multi-elemental analysis and offers great sensitivity, but may be strongly affected by matrix effects induced by high salt contents (> 1 g/l). To perform trace metals analysis both in riverine, estuarine and seawater, we have developed a hyphenated method: ion chelation chromatography coupled on-line with ICP-MS. Iminodiacetate resin, Metpac CC-1 (Dionex), was used to concentrate most of the trace metals, and to separate them from alkaline and alkaline-earth metals. Behaviour of 17 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, In, Zn, V, Tl, Bi, Ag and Sn) towards the resin was qualitatively investigated. A method validation, partly derived from AFNOR standard XPT 90-210, was carried out on 12 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, Bi and In). Replicate measurements of multi-elemental standard solutions were used to check linearity, and to determine repeatability and detection limits. Method accuracy was then assessed by analysing two certified materials: a synthetic freshwater (SRM 1643d), and a natural filtered coastal seawater (NRCC CASS-3). An application assay of natural samples from the Rhône river (France) was eventually carried out, and the analytical results were found to be consistent with previous works.

  12. Uncertainty analysis in comparative NAA applied to geological and biological matrices

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Lange, Camila N.; Favaro, Deborah I.T.; Figueiredo, Ana M.G.

    2015-01-01

    Comparative nuclear activation analysis is a multielemental primary analytical technique that may be used in a rather broad spectrum of matrices with minimal-to-none sample preprocessing. Although the total activation of a chemical element in a sample depends on a rather large set of parameters, when the sample is irradiated together with a well-known comparator, most of these parameters are crossed out and the concentration of that element can be determined simply by using the activities and masses of the comparator and the sample, the concentration of this chemical element in the sample, the half-life of the formed radionuclide and the time between counting the sample and the comparator. This simplification greatly reduces not only the calculations required, but also the uncertainty associated with the measurement; nevertheless, a cautious analysis must be carried out in order to make sure all relevant uncertainties are properly treated, so that the final result can be as representative of the measurement as possible. In this work, this analysis was performed for geological matrices, where concentrations of the interest nuclides are rather high, but so is the density and average atomic number of the sample, as well as for a biological matrix, in order to allow for a comparison. The results show that the largest part of the uncertainty comes from the activity measurements and from the concentration of the comparator, and that while the influence of time-related terms in the final uncertainty can be safely neglected, the uncertainty in the masses may be relevant under specific circumstances. (author)

  13. Uncertainty analysis in comparative NAA applied to geological and biological matrices

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Lange, Camila N.; Favaro, Deborah I.T.; Figueiredo, Ana M.G., E-mail: gzahn@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Comparative nuclear activation analysis is a multielemental primary analytical technique that may be used in a rather broad spectrum of matrices with minimal-to-none sample preprocessing. Although the total activation of a chemical element in a sample depends on a rather large set of parameters, when the sample is irradiated together with a well-known comparator, most of these parameters are crossed out and the concentration of that element can be determined simply by using the activities and masses of the comparator and the sample, the concentration of this chemical element in the sample, the half-life of the formed radionuclide and the time between counting the sample and the comparator. This simplification greatly reduces not only the calculations required, but also the uncertainty associated with the measurement; nevertheless, a cautious analysis must be carried out in order to make sure all relevant uncertainties are properly treated, so that the final result can be as representative of the measurement as possible. In this work, this analysis was performed for geological matrices, where concentrations of the interest nuclides are rather high, but so is the density and average atomic number of the sample, as well as for a biological matrix, in order to allow for a comparison. The results show that the largest part of the uncertainty comes from the activity measurements and from the concentration of the comparator, and that while the influence of time-related terms in the final uncertainty can be safely neglected, the uncertainty in the masses may be relevant under specific circumstances. (author)

  14. [Rapid multi-elemental analysis on four precious Tibetan medicines based on LIBS technique].

    Science.gov (United States)

    Liu, Xiao-na; Shi, Xin-yuan; Jia, Shuai-yun; Zhao, Na; Wu, Zhi-sheng; Qiao, Yan-jiang

    2015-06-01

    The laser-induced breakdown spectroscopy (LIBS) was applied to perform a qualitative elementary analysis on four precious Tibetan medicines, i. e. Renqing Mangjue, Renqing Changjue, 25-herb coral pills and 25-herb pearl pills. The specific spectra of the four Tibetan medicines were established. In the experiment, Nd: YAG and 1 064 nm-baseband pulse laser were adopted to collect the spectra. A laser beam focused on the surface of the samples to generate plasma. Its spectral signal was detected by using spectrograph. Based on the National Institute of Standard and Technology (NIST) database, LIBS spectral lines were indentified. The four Tibetan medicines mainly included Ca, Na, K, Mg and other elements and C-N molecular band. Specifically, Fe was detected in Renqing Changjue and 25-herb pearl pills; heavy mental elements Hg and Cu were shown in Renqing Mangjue and Renqing Changjue; Ag was found in Renqing Changjue. The results demonstrated that LIBS is a reliable and rapid multi-element analysis on the four Tibetan medicines. With Real-time, rapid and nondestructive advantages, LIBS has a wide application prospect in the element analysis on ethnic medicines.

  15. Handbook of practical X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Beckhoff, B.; Wedell, R.; Wolff, H.

    2006-01-01

    X-ray fluorescence analysis (XRF) is a reliable multi-elemental and nondestructive analytical method widely used in research and industrial applications. This practical handbook provides self-contained modules featuring XRF instrumentation, quantification methods, and most of the current applications. The broad spectrum of topics is due to the efforts of a large number of authors from a variety of different types of institutions such as universities, research institutes, and companies. The book gives a survey of the theoretical fundamentals, analytical instrumentation, software for data processing, various excitation regimes including gracing incidents and microfocus measurements, quantitative analysis, applications in routine and micro analysis, mineralogy, biology, medicine, criminal investigations, archeology, metallurgy, abrasion, microelectronics, environmental air and water analysis. It gives the basic knowledge on this technique, information on analytical equipment and guides the reader to the various applications. This practical handbook is intended as a resource for graduate students, research scientists, and industrial users. (orig.)

  16. Handbook of practical X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Beckhoff, B. [Physikalisch-Technische Bundesanstalt, Berlin (Germany). X-ray Spectrometry; Kanngiesser, B. [Technische Univ. Berlin (Germany). Inst. fuer Atomare Physik und Fachdidaktik; Langhoff, N. [IfG-Institute for Scientific Instruments GmbH, Berlin (Germany); Wedell, R.; Wolff, H. (eds.) [Institut fuer Angewandte Photonik e.V., Berlin (Germany)

    2006-07-01

    X-ray fluorescence analysis (XRF) is a reliable multi-elemental and nondestructive analytical method widely used in research and industrial applications. This practical handbook provides self-contained modules featuring XRF instrumentation, quantification methods, and most of the current applications. The broad spectrum of topics is due to the efforts of a large number of authors from a variety of different types of institutions such as universities, research institutes, and companies. The book gives a survey of the theoretical fundamentals, analytical instrumentation, software for data processing, various excitation regimes including gracing incidents and microfocus measurements, quantitative analysis, applications in routine and micro analysis, mineralogy, biology, medicine, criminal investigations, archeology, metallurgy, abrasion, microelectronics, environmental air and water analysis. It gives the basic knowledge on this technique, information on analytical equipment and guides the reader to the various applications. This practical handbook is intended as a resource for graduate students, research scientists, and industrial users. (orig.)

  17. Particle-induced X-ray emission: thick-target analysis of inorganic materials in the determination of light elements

    International Nuclear Information System (INIS)

    Perez-Arantegui, J.; Castillo, J.R.; Querre, G.

    1994-01-01

    Particle-induced X-ray emission (PIXE) has been applied to the analysis of inorganic materials to determine some elements with Z < 27: Na, Mg, Al, Si, K, Ca, Ti, Mn and Fe, in thick-target analysis. A PIXE method has been developed for the analysis of geological materials, ceramics and pottery. Work has been carried out with an ion beam analytical system, using a low particle beam energy. Relative sensitivity, detection limits, reproducibility and accuracy of the method were calculated based on the analysis of geological standard materials (river sediments, argillaceous limestone, basalt, diorite and granite). Analysis using PIXE offers a number of advantages, such as short analysis time, multi-elemental and nondestructive determinations, and the results are similar to those obtained with other instrumental techniques of analysis. (Author)

  18. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    Science.gov (United States)

    Sun, Z. J.; Wells, D.; Segebade, C.; Green, J.

    2011-06-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  19. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    International Nuclear Information System (INIS)

    Sun, Z. J.; Wells, D.; Green, J.; Segebade, C.

    2011-01-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  20. An Investigation of Trace Elements in Marine and Lacustrine Deposits by Means of a Neutron Activation Method

    Energy Technology Data Exchange (ETDEWEB)

    Landstroem, O; Samsahl, K; Wenner, C G

    1967-10-15

    A neutron activation method for multi-elemental analysis was applied to argillaceous deposits from the Viskan Valley on the Swedish West Coast, an area in which transgressions and regressions of the sea have occurred during the postglacial time. These changes between fresh-water and marine stages are well known from earlier geologic investigations. Analysis could therefore be performed of samples of known marine (brackish) and lacustrine origin. In a preliminary test on four samples, taken from two marine layers and two lacustrine layers, altogether 30 elements were quantitatively determined, namely As, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hf, Hg, La, Lu, Mn, Na, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, W, Yb, Zn and Zr. Several elements showed a difference in concentration between the marine and the fresh-water layers. Br, Hg, Mn, Se, As and Sb were more thoroughly investigated in three boreholes from different sections of the valley. Br and Se had high means in the most pronounced marine samples of the fiord deposits. Moreover, Mn showed a fourfold increase just in the transition stage between the older sea fiord and the older lage stage.

  1. An Investigation of Trace Elements in Marine and Lacustrine Deposits by Means of a Neutron Activation Method

    International Nuclear Information System (INIS)

    Landstroem, O.; Samsahl, K.; Wenner, C.G.

    1967-10-01

    A neutron activation method for multi-elemental analysis was applied to argillaceous deposits from the Viskan Valley on the Swedish West Coast, an area in which transgressions and regressions of the sea have occurred during the postglacial time. These changes between fresh-water and marine stages are well known from earlier geologic investigations. Analysis could therefore be performed of samples of known marine (brackish) and lacustrine origin. In a preliminary test on four samples, taken from two marine layers and two lacustrine layers, altogether 30 elements were quantitatively determined, namely As, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hf, Hg, La, Lu, Mn, Na, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, W, Yb, Zn and Zr. Several elements showed a difference in concentration between the marine and the fresh-water layers. Br, Hg, Mn, Se, As and Sb were more thoroughly investigated in three boreholes from different sections of the valley. Br and Se had high means in the most pronounced marine samples of the fiord deposits. Moreover, Mn showed a fourfold increase just in the transition stage between the older sea fiord and the older lage stage

  2. Analysis of bone marrow stromal cell transferred bacterial {beta}-galactosidase gene by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Toshiro [Tokyo Metropolitan Geriatric Hospital, Tokyo (Japan). Dept. of Blood Transfusion and Hematology; Hibino, Hitoshi; Tani, Kenzaburo; Asano, Shigetaka; Futatugawa, Shouji; Sera, Kouichiro

    1997-12-31

    PIXE, Particle Induced X-ray Emission, is a powerful, multi-elemental analysis method which has many distinguishing features and has been used in varies research fields. Recently the method of applying baby cyclotrons for nuclear medicine to PIXE has been developed. This enables us to study biomedical phenomena from the physical point of view. Mouse bone marrow stromal cells were transferred bacterial {beta}-galactosidase gene (LacZ gene) by murine retroviral vectors. Analysis of the bone marrow stromal cells with the LacZ gene by PIXE revealed remarkable changes of intracellular trace elements compared with the normal control cells. These results indicate that gene transfer by retroviral vectors may bring about a dynamic change of intracellular circumstances of the target cell. (author)

  3. Description of an XRF system for multielemental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wielopolski, L.; Zhang, R.; Cohn, S.H.

    1986-01-01

    An X-ray fluorescence (XRF) system which uses radioisotopes in an orthogonal configuration between the source, sample, and detector is described. The advantage of such a system is that for large (bulk) samples or for in vivo measurements the background due to Compton scattering in the sample is minimized. High reproducibility for nonuniform samples is obtained by reducing the sample size and thus the effects of non-uniformity in the spatial response of such a system. Germane to any accurate analytical method is the use of proper mathematical algorithms for data evaluation. The problem is acute, in particular, when photopeaks with low counting statistics are to be analyzed. In the case of a single photopeak on flat, background optimal energy window size, which maximizes the signal-to-noise ratio, for trapezoidal intergration is described. The sensitivity and minimum detection limit at different energies together with background considerations are discussed. 13 refs., 8 figs., 2 tabs.

  4. Description of an XRF system for multielemental analysis

    International Nuclear Information System (INIS)

    Wielopolski, L.; Zhang, R.; Cohn, S.H.

    1986-01-01

    An X-ray fluorescence (XRF) system which uses radioisotopes in an orthogonal configuration between the source, sample, and detector is described. The advantage of such a system is that for large (bulk) samples or for in vivo measurements the background due to Compton scattering in the sample is minimized. High reproducibility for nonuniform samples is obtained by reducing the sample size and thus the effects of non-uniformity in the spatial response of such a system. Germane to any accurate analytical method is the use of proper mathematical algorithms for data evaluation. The problem is acute, in particular, when photopeaks with low counting statistics are to be analyzed. In the case of a single photopeak on flat, background optimal energy window size, which maximizes the signal-to-noise ratio, for trapezoidal intergration is described. The sensitivity and minimum detection limit at different energies together with background considerations are discussed. 13 refs., 8 figs., 2 tabs

  5. Application of X-ray fluorescence analytical techniques in phytoremediation and plant biology studies

    International Nuclear Information System (INIS)

    Necemer, Marijan; Kump, Peter; Scancar, Janez; Jacimovic, Radojko; Simcic, Jurij; Pelicon, Primoz; Budnar, Milos; Jeran, Zvonka; Pongrac, Paula; Regvar, Marjana; Vogel-Mikus, Katarina

    2008-01-01

    Phytoremediation is an emerging technology that employs the use of higher plants for the clean-up of contaminated environments. Progress in the field is however handicapped by limited knowledge of the biological processes involved in plant metal uptake, translocation, tolerance and plant-microbe-soil interactions; therefore a better understanding of the basic biological mechanisms involved in plant/microbe/soil/contaminant interactions would allow further optimization of phytoremediation technologies. In view of the needs of global environmental protection, it is important that in phytoremediation and plant biology studies the analytical procedures for elemental determination in plant tissues and soil should be fast and cheap, with simple sample preparation, and of adequate accuracy and reproducibility. The aim of this study was therefore to present the main characteristics, sample preparation protocols and applications of X-ray fluorescence-based analytical techniques (energy dispersive X-ray fluorescence spectrometry-EDXRF, total reflection X-ray fluorescence spectrometry-TXRF and micro-proton induced X-ray emission-micro-PIXE). Element concentrations in plant leaves from metal polluted and non-polluted sites, as well as standard reference materials, were analyzed by the mentioned techniques, and additionally by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). The results were compared and critically evaluated in order to assess the performance and capability of X-ray fluorescence-based techniques in phytoremediation and plant biology studies. It is the EDXRF, which is recommended as suitable to be used in the analyses of a large number of samples, because it is multi-elemental, requires only simple preparation of sample material, and it is analytically comparable to the most frequently used instrumental chemical techniques. The TXRF is compatible to FAAS in sample preparation, but relative to AAS it is fast, sensitive and

  6. Epiphytic lichens as quantitative biomonitors for atmospheric element deposition

    International Nuclear Information System (INIS)

    Jeran, Z.; Jacimovic, J.; Smodis, B.; Batic, F.

    2000-01-01

    Epiphytic lichens are being used as passive and active biomonitors of trace elements in Slovenia. The lichen Hypogymnia physodes (L.) Nyl. was exposed at three locations (two in the vicinity of a coal fired-power plant, and one at a reference location) for 8 months. At the same locations air particulate matter and total deposition were collected on a monthly basis. The k 0 -method of neutron activation analysis, using the TRIGA Mark II reactor at the 'Jozef Stefan' Institute, was employed for multielemental nondestructive analysis of all samples. The influence of the power plant on the concentration levels of some elements in the transplanted lichens, air particulates and total deposition is discussed and their correlation presented. (author)

  7. Assessment of pollutants in manzala lake using gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Abdel-Haleem, A.S.; Zaghloul, R.; El-Abbady, W.H.; Hassan, A.M.

    1996-01-01

    Multielemental analysis of water samples taken from the area of manzala lake in the east-north of river Nile delta of egypt, has been performed. Prompt gamma neutron activation analysis (PGNAA) technique is applied to determine the elemental concentrations. The samples have been irradiated by means of (PGNAA) facility using a Cf 252 isotopic neutron source with a total flux of 1.5 x 10 5 n cm 2 s -1 for 300 min irradiation time. The evaluation of Cd, Gd, Sm, Pb, Zn, Co and Hg as trace elements in these samples is reported. 1 fig., 2 tabs

  8. 1. Latin American Workshop on Total Reflection X-Ray Fluorescence (TXRF) and its Applications: TARABANA 99. Programme and Abstracts

    International Nuclear Information System (INIS)

    Vegas C, Fredy; Greaves N, Eduardo; Marco P, Lue-Meru

    1999-01-01

    It concerns about the advances in Total Reflection X-Ray Fluorescence (TXRF) instrumentation; structure, characteristic and potential of TXRF equipment used for chemical multielemental survey; TXRF: an approach to nano analysis; microanalytical investigation of environmental samples by TXRF spectrometry; TXRF of low Z elements; assessment of serum selenium levels in 2 month old sucking calves using TXRF: A powerful method to investigate the elemental composition of spheroids; environmental applications of TXRF; use of modifiers for the elimination in situ of chlorides in the analysis of TXRF; experimental methodology and analysis spectra for the determination of mercury by means of TXRF using amalgamation with gold; multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and rutherford forward scattering; determination of metal in samples of handmade penca; determination of oligo elements, platinum and relationship Zn/Cu in samples of blood serum and urine in oncological pediatric patient [es

  9. Multi-elemental analysis of marine sediments of Sorsogon Bay using x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gonzales, Ralph Roly A.; Quirit, Leni L.; Rosales, Colleen Marciel F.; Pabroa, Preciosa Corazon B.; Sta Maria, Efren J.

    2011-01-01

    Metal composition and nutrient loadings of our bodies of water, when uncontrolled, may cause harmful bacterial contamination and pose threats in aquatic and human life. Toxic and trace element inputs in Sorsogon Bay sediments were determined using nuclear analytical techniques, more specifically, x-ray fluorescence spectrometry, in this study. Pre-treated marine sediment samples from Sorsogon Bay were homogenized using SPEX # 8000 mixer/mill and agate mortar and pestle, pelletized into 31-mm flat discs using SPEX 3630 X-Press and analyzed using PAN Analytical Epsilon 5 EDX X-ray Fluorescence Spectrometer with the emission and transmission method using silver and germanium secondary targets. Spectrum fitting performed using AXIL (Analysis of X-ray Spectra by Iterative Least-Squares Fitting), a subprogram in Quantitative X-ray Analysis System developed by the International Atomic Energy Agency and Quantitative Analysis of Environmental Samples program, was used for quantification of results. Results indicate generally moderate to high metal enrichment, specifically manganese, lead, cadmium, zinc and copper. Mercury and iron level enrichment are found to be low, marking an improvement from previous studies indicating high enrichment of these metals. (author)

  10. MultiSIMNRA: A computational tool for self-consistent ion beam analysis using SIMNRA

    International Nuclear Information System (INIS)

    Silva, T.F.; Rodrigues, C.L.; Mayer, M.; Moro, M.V.; Trindade, G.F.; Aguirre, F.R.; Added, N.; Rizzutto, M.A.; Tabacniks, M.H.

    2016-01-01

    Highlights: • MultiSIMNRA enables the self-consistent analysis of multiple ion beam techniques. • Self-consistent analysis enables unequivocal and reliable modeling of the sample. • Four different computational algorithms available for model optimizations. • Definition of constraints enables to include prior knowledge into the analysis. - Abstract: SIMNRA is widely adopted by the scientific community of ion beam analysis for the simulation and interpretation of nuclear scattering techniques for material characterization. Taking advantage of its recognized reliability and quality of the simulations, we developed a computer program that uses multiple parallel sessions of SIMNRA to perform self-consistent analysis of data obtained by different ion beam techniques or in different experimental conditions of a given sample. In this paper, we present a result using MultiSIMNRA for a self-consistent multi-elemental analysis of a thin film produced by magnetron sputtering. The results demonstrate the potentialities of the self-consistent analysis and its feasibility using MultiSIMNRA.

  11. Activation analysis. Chapter 4

    International Nuclear Information System (INIS)

    1976-01-01

    The principle, sample and calibration standard preparation, activation by neutrons, charged particles and gamma radiation, sample transport after activation, activity measurement, and chemical sample processing are described for activation analysis. Possible applications are shown of nondestructive activation analysis. (J.P.)

  12. Multielemental neutron activation analysis of essential elements in pragya peya - a herbal drink and its constituents

    International Nuclear Information System (INIS)

    Ashok Kumar; Garg, A.N.; Nair, A.G.C.; Reddy, A.V.R.

    2003-01-01

    Pragya peya-a mixture of 12 herbs often recommended as a drink after boiling in water or milk has been analysed for 15 elements (Al, Br, Ca, Cl, Co, Cr, Fe, K, Mg, Mn, Na, P, Rb, V, and Zn) by short (5 min) and long (7 h) term irradiation in Apsara reactor followed by high resolution gamma ray spectrometry. Several constituent herbs have been found enriched in one or more essential nutrients. The elemental contents have been attributed to the overall nutritive and therapeutic importance. (author)

  13. PIXE analysis of exhaust gas from diesel engine

    International Nuclear Information System (INIS)

    Miyake, Hirosi; Michijima, Masami; Onishi, Masayuki; Fujitani, Tatsuya.

    1986-01-01

    The variation of elemental concentrations in exhaust gas of a Diesel engine with the outputs was studied. Particulates in high temperature gas were collected on silica fiber filters and analyzed by PIXE method. Concentrations of S and V were nearly proportional to particulate masses and fuel consumption rates per discharging rates of exhaust gas respectively. While, concentrations of Fe and Mn were markedly increased together with engine outputs, and Mn/Fe ratios were nearly equal to those of the material of piston rings and the cylinder liner. Concentrations of the elements contained in lubricant, such as Ca and Mo, were also conspicuously increased with the outputs. It was shown that PIXE analysis is a useful tool for engine diagonostics owing to its high sensitive multi-elemental availability without chemical treatments. (author)

  14. Metal and trace element sediment assessment from Ribeira do Iguape river, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Francisco J.V. de; Quinaglia, Gilson A., E-mail: franciscovc@cetesbnet.sp.gov.br, E-mail: gilsonn@cetesbnet.sp.gov.br [CETESB - Companhia Ambiental do Estado de Sao Paulo, SP (Brazil). ELTA - Setor de Analises Toxicologicas; Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (LAN/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Laboratorio de Analise por Ativacao Neutronica; Franklin, Robson L.; Ferreira, Francisco J., E-mail: robsonf@cetesbnet.sp.gov.br, E-mail: franciscoj@cetesbnet.sp.gov.br [CETESB - Companhia Ambiental do Estado de Sao Paulo, SP (Brazil). ELAI - Setor de Quimica Inorganica

    2011-07-01

    The watershed region of the Ribeira do Iguape River and the estuarine complex of the Paranagua-Iguape- Cananeia and the various river basins located between this region and the Atlantic Ocean, is known as the Ribeira Valley. The Ribeira do Iguape River runs a total length of approximately 470 km, being the main source of fresh water in the Estuarine Complex of the Iguape-Cananeia-Paranagua (Lagamar). The Ribeira do Iguape River is the last major river in the State of Sao Paulo that has not been altered by dams. During virtually the entire 20th century, the region of the Ribeira Valley was the scene of constant environmental degradation resulting from the intense exploration and refining of lead, zinc and silver ores that were processed in the mines of the region, in a rudimentary way and without any control over environmental impacts. Since 1996, all such activities ceased, however, leaving behind a huge amount of environmental liabilities. This study aims to investigate the presence and concentration levels of metals and semi-metals arsenic (As), cadmium (Cd) and lead (Pb) in the sediment and water of aquatic systems of Ribeira do Iguape River and its tributaries, for an environmental assessment and monitoring of the region. The determination of these elements was carried out by GF AAS technique for water samples and ICP OES for the sediment samples. This study also assessed the occurrence of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, Zn) and rare earth elements (La, Ce, Eu, Nd, Sm, Lu, Tb and Yb) by Neutron Activation Analysis (NAA). Validation of both methodologies, according to precision and accuracy, was done by reference material analyses. The results obtained for As, Cd and Pb were compared to the Canadian Environmental oriented values (TEL and PEL). The results obtained for multielemental analyses in the sediment samples were compared to UCC values (Upper Continental Crust). (author)

  15. Metal and trace element sediment assessment from Ribeira do Iguape river, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Castro, Francisco J.V. de; Quinaglia, Gilson A.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.

    2011-01-01

    The watershed region of the Ribeira do Iguape River and the estuarine complex of the Paranagua-Iguape- Cananeia and the various river basins located between this region and the Atlantic Ocean, is known as the Ribeira Valley. The Ribeira do Iguape River runs a total length of approximately 470 km, being the main source of fresh water in the Estuarine Complex of the Iguape-Cananeia-Paranagua (Lagamar). The Ribeira do Iguape River is the last major river in the State of Sao Paulo that has not been altered by dams. During virtually the entire 20th century, the region of the Ribeira Valley was the scene of constant environmental degradation resulting from the intense exploration and refining of lead, zinc and silver ores that were processed in the mines of the region, in a rudimentary way and without any control over environmental impacts. Since 1996, all such activities ceased, however, leaving behind a huge amount of environmental liabilities. This study aims to investigate the presence and concentration levels of metals and semi-metals arsenic (As), cadmium (Cd) and lead (Pb) in the sediment and water of aquatic systems of Ribeira do Iguape River and its tributaries, for an environmental assessment and monitoring of the region. The determination of these elements was carried out by GF AAS technique for water samples and ICP OES for the sediment samples. This study also assessed the occurrence of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, Zn) and rare earth elements (La, Ce, Eu, Nd, Sm, Lu, Tb and Yb) by Neutron Activation Analysis (NAA). Validation of both methodologies, according to precision and accuracy, was done by reference material analyses. The results obtained for As, Cd and Pb were compared to the Canadian Environmental oriented values (TEL and PEL). The results obtained for multielemental analyses in the sediment samples were compared to UCC values (Upper Continental Crust). (author)

  16. Trace elements in some new Romanian phytotherapeutic drugs determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Salagean, M.; Pantelica, A.; Ionescu-Tirgoviste, C.

    1997-01-01

    Instrumental neutron activation analysis (INAA) has been performed on four new Romanian phytotherapeutic drugs registered us Fitolip, Fitodiab, Retinomion and Neuromion. The drugs were very well tolerated in clinical trials and are used in diabetes and other chronic diseases. They were prepared in the form of tablets made from dried powders of fruits, flowers, leaves and shells of plants used in non-conventional medicine. All four products are reach in various bioactive substances such as flavones, flavonoids, anthocyans, terpenes, rutosides, vitamins and essential fatty acids. Samples and multielemental reference materials were irradiated in a thermal neutron flux of 1.1 x 10 11 n.cm -2 .s -1 and measured with a high resolution Ge(Li) detector. 28 mineral elements were found, including Mg, K, Ca, Na and Fe at percent and sub-percent levels; Cl, Al and Mn between tens and thousands of ppm; Zn, Br, Rb and Ba up to tens of ppm; Cr, Cu, Co and V in the ppm range; and Sc, As, Sb, Cs, Lu, La, Ce, Sm, Hf, Au, Hg and Th up to hundreds of ppb. The intake of mineral elements provided by a cure of 3 pills/day shows the following: 1. None of the toxic elements As and Hg in the four drugs exceeds a noxious level; 2. Mg is the most abundant macro-element and a cure covers 15 - 60 % of the daily requirements; 3. Among essential microelements, Co may provide even more than 100% of the daily requirements; other elements may give small but significant fractions of the necessary daily amounts, e.g. 3-30% for Cr, 5-20% for Mn, and 2-10% for Fe; 4. The supply of Al, the most abundant unessential metal represents 6 - 40 % of the known daily intake. Thus a 3 pills/day cure could contribute positively to the therapy of various diseases by providing Mg, Mn, Cr (a trace element deficient in diabetes), Fe and Co, but higher daily doses could result in a Co oversupply. Further in INAA studies on biological examples from patients taking these new medicines are needed to understand the

  17. Elemental analysis of bronze artifacts by muonic X-ray spectroscopy

    International Nuclear Information System (INIS)

    Ninomiya, Kazuhiko; Shinohara, Atsushi; Kubo, Michael K.; Strasser, Patrick; Nagatomo, Takashi; Kawamura, Naritoshi; Shimomura, Koichiro; Miyake, Yasuhiro; Kobayashi, Yoshio; Ishida, Katsuhiko; Higemoto, Wataru; Suzuki, Takao; Saito, Tsutomu

    2015-01-01

    A quantitative and multi-elemental analysis method for bulk samples based on muonic X-ray spectroscopy was applied to bronze artifacts (Tempo-Tsuho coins and a Seiun-kyo mirror). This method is based on the measurement of the characteristic high-energy muonic X-rays emitted in a sample after muon irradiation. The elemental compositions of these bronze artifacts were determined from muonic X-ray intensities in a non-destructive manner, using the relation between the muonic X-ray intensity and the elemental composition of the Cu–Sn–Pb alloy system. The analyzed values agreed well with those determined by X-ray fluorescence spectroscopy. We also estimated the detection limit of this method in the present experimental setup as 0.81 wt% of the background signal of the muonic X-ray spectra. (author)

  18. Determination of heavy metals and other elements in sediments from Sepetiba Bay (RJ, Brazil) by neutron activation analysis

    International Nuclear Information System (INIS)

    Pellegatti, Fabio

    2000-01-01

    Sepetiba Bay, located about 60 km south of the city of Rio de Janeiro, Brazil, is one of the most important fishery areas in the State of Rio de Janeiro. A large harbor brought up a lot of industrial investment in that area. Since the 1970's, the Sepetiba region has undergone fast industrial expansion, leading to high levels of pollution by metals. For the last two decades, an industrial park composed of about 400 industrial plants, basically metallurgical, was established in the Sepetiba Bay basin, releasing its industrial waste either straight into the bay or through local rivers. Metal contamination in the bay for some metals, such as Zn, has already exceeded acceptable levels. Many authors have studied the distribution and behavior of heavy metals and another elements in the bay, but only few elements have been focused (Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn). This is probably due to the fact that the analytical technique most employed has been atomic absorption spectrometry, which is not a multi-elemental technique. In this work, Instrumental Neutron Activation Analysis (INAA) was applied to the determination of the elements As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Lu, Nd, Rb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn in 28 bottom sediment samples and four sediment cores from Sepetiba Bay. The elements Co, Cr, Cs, Fe, Sc, Ta and Zn presented similar behavior in the bottom sediments, showing higher concentration along the Northern coast of the bay, where most of the fluvial water flows out to the bay. The contamination of Sepetiba Bay was also assessed by the analysis of four sediment cores. Two of them were sampled in the Eastern part of the bay, where the industrial park is located, whereas the other two were sampled in the Western part of the bay, a more preserved region. For each region, two cores were sampled within the mangrove trees and the others at the edge of the tidal flat. The results showed that, the sediments displayed higher metal concentration within the

  19. Proton-induced X-ray emission (PIXE) spectrometry - state of the art

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1986-01-01

    The development of the PIXE method for multielemental analysis is described. A brief account is given of the physical principles and the experimental arrangements. The use of PIXE is illustrated by a number of typical applications in geology, biology, medicine and environmental research. (orig.) [de

  20. Trace element content of ginger and sage medicinal plants from Algeria

    International Nuclear Information System (INIS)

    Lamari, Z.; Larbi, R.; Yagoubi, B.

    2010-01-01

    Full text: Instrumental Neutron Activation Analysis has been used to multielemental determination in the Zingiber Officinalis and Salvia Officinalis, plants used in traditional medicine therapy in Algeria and in most countries. The concentrations of five elements Co, Cr, Sc, Sb and Rb have been determined by long irradiation time with 2.13E12 n.cm -2 s -1 thermal flux at NUR Algerian Reactor, all these elements are present at trace level the implication in Human health is discussed. The quality control of the measurements has been evaluated by analysing of HAY (V-10) IAEA - Standard reference material

  1. INAA of Airborne Particulate Matter Collected in Bangkok and Pathumthani 2002-2004

    International Nuclear Information System (INIS)

    Chueinta, W.; Bunprapob, S.

    2005-01-01

    This paper presents the summary report of the monitoring study on ambient air quality in Bangkok metropolis and its boundary covering the period from 2002 to 2004. The work performed included sampling of fine and coarse fractions of particulate matter at the sites representing urban and suburban areas; measurement of particle mass concentration and elemental concentration; and data interpretation. Instrumental neutron activation by use of research reactor facilities at Office of Atoms for Peace was carried out for multielemental analysis of all filter samples collected. Twenty elements were determined. The database of the three consecutive years are summarized and reviewed in this paper

  2. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  3. Automation of activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Ivanets, V.N.; Filippov, V.V.

    1985-01-01

    The basic data on the methods and equipment of activation analysis are presented. Recommendations on the selection of activation analysis techniques, and especially the technique envisaging the use of short-lived isotopes, are given. The equipment possibilities to increase dataway carrying capacity, using modern computers for the automation of the analysis and data processing procedure, are shown

  4. Estimation of environmental situation in Tashkent region using nuclear-physical methods

    International Nuclear Information System (INIS)

    Danilova, E.A.; Kist, A.A.; Mukhina, A.V.; Osinskaya, N.S.; Khusniddinova, S.Kh.; Zaredinov, D.A.; Ten, O.L.

    2012-01-01

    Task of the present study is elaboration of strategy and methodology for creation of the ecological portrait of the Tashkent region. For estimation of everage values of contamination of surface waters, soils etc., the neutron activation analysis has been used due to its advantages, especially of multi- element s determination, high sensitivity, and independence of the types of studied samples. Multielemental analysis of samples of atmospheric air, soils, drinking water, and human hair as the indicators of the body elemental status allows us to estimate the environmental ecological situation in the Tashkent region, to detect districts with the higher concentration of elements, to make maps of distribution and to compare with medical statistics of diseases. (authors)

  5. Fast XRF analysis of mineral elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Constantinescu, B.; Preoteasa, E.

    2001-01-01

    Dental composites, made of particles of glass, ceramics or quartz embedded in an organic polymer matrix, extensively replaced silver amalgam in tooth fillings and enabled new applications for restorative dentistry. Long-term alteration of dental fillings together with market pressure motivates the development of composites at a high rate, largely by progress of materials forming their mineral phase. Therefore, dental composites constantly bring at the interface with enamel and dentine new elements foreign to the organism, whose biological action has not been studied. Atomic and nuclear methods for surface multielemental analysis have been used in dental research but not for composites. X-ray fluorescence (XRF) is suited for the fast microanalytical screening of the elements and of their changes at the biomaterial's surface. The potential of radioisotope-excited XRF for the analysis of dental composites has been examined. Flat disk-shaped samples of composites have been prepared and polymerized chemically or by irradiation with intense 420-500 nm light. The measurements were performed with a spectrometric chain containing a 30 mCi source of 241 Am, a Si(Li) detector, and a multichannel analyzer. The spectra were built up for 2000-6000 sec. The characteristic X lines were integrated and normalized to source lines. The following Z ≥ 20 elements were detected in the studied composites: Ba only in Charisma (Kulzer) and Pekafill (Bayer); Zr, Ba, Yb in Tetric Ceram, and Ca, Ba, Yb together with traces of possibly Ti and Fe in Ariston (both from Vivadent); Zr, Hf in Valux Plus (3M Dental); and Sr, Ba together with some trace element, seemingly Cu, in F2000 Compomer (3M Dental) and with other trace elements like Ca, Fe in Surefil (Dentsply). Among older materials, Concise (3M Dental) contained only light (Z 3 that releases F for protection of enamel and dentine. Yb, Zr, Ba, Hf improve the radiological opacity of the materials. Some elements may accompany others as

  6. Activation analysis in water chemistry

    International Nuclear Information System (INIS)

    Szabo, A.; Toth, A.

    1978-01-01

    The potential applications of activation analysis in water chemistry are discussed. The principle, unit operations, the radiation sources and measuring instruments of activation analysis are described. The sensitivity of activation analysis is given in tabulated form for some elements of major importance in water chemistry and the elements readily accessible to determination by measurement of the spontaneous gamma radiation are listed. A few papers selected from the recent international professional literature are finally reviewed, in which the authors report on the results obtained by activation analysis applied to water chemistry. (author)

  7. Analysis of ancient masterly pieces of work by means of X-ray fluorescence analysis by dispersion in the energy

    International Nuclear Information System (INIS)

    Cesareo, R.; Cappio B, C.; Brunetti, A.; Rosales, M.A.; Castellano, A.; Gigante, G.E.; Fiorini, C.

    2004-01-01

    Energy dispersive X-ray fluorescence (EDXRF) analysis has been widely used for the analysis of works of art because it is non-destructive, multi-elemental, simple to utilize, and relatively inexpensive. In the last few years, miniaturized and portable X-ray tubes and high-resolution semiconductor detectors have been developed. This progress allowed the design and construction of portable equipments that can be easily transported all over the world, for use in museums, excavations, etc. In this work, these portable systems will be described and their usefulness demonstrated in the analysis of objects of archaeological value. First, we present the analysis of a lot of gold prehispanic jewels from the Museo del Templo Mayor in Mexico City; in the second place we present the results of analysis of the golden altar of St. Ambrogio in Milan, which is considered one of the most important goldsmith's works ever realized and the gold pigments from the fresco 'The chapel of the Scrovegni' by Giotto. In the third place we give a brief account of Mycenaean and pre-Mycenaean gold objects from the Museum Benaki in Athens. Finally, the results of bulk nuragic copper based ingots from the nuragic village of St. Imbenia are presented. (Author) 19 refs., 5 tabs., 8 figs

  8. Fast neutron activation analysis

    International Nuclear Information System (INIS)

    Pepelnik, R.

    1986-01-01

    Since 1981 numerous 14 MeV neutron activation analyses were performed at Korona. On the basis of that work the advantages of this analysis technique and therewith obtained results are compared with other analytical methods. The procedure of activation analysis, the characteristics of Korona, some analytical investigations in environmental research and material physics, as well as sources of systematic errors in trace analysis are described. (orig.) [de

  9. Multi-elemental characterization of Cuban natural zeolites

    International Nuclear Information System (INIS)

    Rizo, O.D.; Peraza, E.F.H.

    1997-01-01

    Concentration of 38 elements in samples from four important Cuban zeolite beds have been obtained by Instrumental Neutron Activation (INAA) and X-ray Fluorescence analyses (XRFA). In comparison with other analytical techniques good agreement was reached. The concentration values of minor element Ba, Sr, Zn and Mn and 25 trace element (including 9 REE) are at the first time reported in Cuban zeolite. It is important for the zeolite evaluation in different industrial uses. (author)

  10. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Barbosa, R.F.; Anjos, M.J. dos; Jesus, E.F.O. de; Lopes, R.T.; Moreira, S.

    2008-01-01

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  11. Activation analysis in national economy

    International Nuclear Information System (INIS)

    1974-01-01

    The collected papers are based on the materials of the III All-Union Activation Analysis Meeting. The papers selected deal with the theoretical questions of the activation analysis, its hardware, latest developments in the field of automatic analysis and computer methods employment in the treatment of analytical information. Described are the new techniques for determination of a large number of elements in samples of biological and geological origin. Some results of the use of the activation analysis in various fields of science and technology are provided. The volume reflects the present status of activation analysis techniques in the USSR and might be of interest both for specialists, and for those involved in obtaining and using information on the composition of substances. (auth.)

  12. Multielemental analysis in Brazilian cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Moreira, Silvana

    2005-01-01

    In order to identify major and trace elements in conventional and light Brazilian cigarettes, Total Reflection X-Ray Fluorescence with Synchrotron Radiation (SR-TXRF) was used. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. This technique enables detection limit is in the ngg -1 range, which is very useful in elemental tobacco smoke analysis, since it presents most of its elements at a trace level. The major elements identified in tobacco samples were: S, Cl, K, Ca, Mn, Fe and Cd, and the trace elements were: Ti, Cr, Ni, Cu, Zn, Br, Rb, Sr and Ba. However in tobacco smoke samples, there were only two major elements: K and Ca, the others were present a trace level. The rate transfer of tobacco to tobacco smoke was about 2.5 % for all elements studied. (author)

  13. Activation analysis. Detection limits

    International Nuclear Information System (INIS)

    Revel, G.

    1999-01-01

    Numerical data and limits of detection related to the four irradiation modes, often used in activation analysis (reactor neutrons, 14 MeV neutrons, photon gamma and charged particles) are presented here. The technical presentation of the activation analysis is detailed in the paper P 2565 of Techniques de l'Ingenieur. (A.L.B.)

  14. Analysis of fertilizers and rectification by nuclear techniques

    International Nuclear Information System (INIS)

    Padilla, R.; Capote, G.; Pupo, I.; Lopez, D. R.; Gonzalez, M. A.; Estevez, J.; Hernandez, A. T.; Battles, J.; Morejon, L.

    1997-01-01

    Near the end of 1992 Cuba was affected by a neuropathy that by it's high incidence ached an epidemic character. The most of the specialists thought that the causes of the disease should be toxic-nutritional character. Because of that, it was important to determine the content of toxic elements in samples of agricultural products of the human alimentation, in the soils in which they were obtained, such as in the water and the fertilizers employed during the process of production. During the development of this work, 6 commercial samples of fertilizers were analyzed, a sample of mob and 25 samples of phosphoric rocks of 'La pimienta', 'Trinidad de Guedes', and 'Guines Pipian' deposits, applied to the soils of 17 zones of the country's western region (with high illness incidence) for the fertilization of the soils. The multielemental composition was studied, and especially, the content of toxic elements at trace levels employing the Fluorescence of X Rays by Dispersive Energy and the Neutron Activation Analysis (Naa). The concentrations of the following elements are reported: K, Ca, Sc, Ti, V, Cr, Mn, Fe, Ni, Co, Zn, As, Br, Rb, Sr, Y, Zr, Nb, Ag, Cd, I, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Tm, Yb, Lu, Hf, Ta, W, Th, and U. (author) [es

  15. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D D; Bailey, G; Martin, J; Garton, D; Noorman, H; Stelcer, E; Johnson, P [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1994-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  16. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D.D.; Bailey, G.; Martin, J.; Garton, D.; Noorman, H.; Stelcer, E.; Johnson, P. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1993-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  17. Spectroscopy of laser-produced plasmas

    Indian Academy of Sciences (India)

    It is a well-known fact that laser-induced breakdown spectroscopy (LIBS) has emerged as one of the best analytical techniques for multi-elemental compositional analysis of samples. We report assembling and optimization of LIBS set up using high resolution and broad-range echelle spectrograph coupled to an intensified ...

  18. Neutron activation analysis in Romania

    International Nuclear Information System (INIS)

    Apostolescu, St.

    1985-01-01

    The following basic nuclear facilities are used for neutron activation analysis: a 2000 KW VVR-S Nuclear Reactor, a U-200 Cyclotron, a 30 MeV Betatron, several 14 MeV neutron generators and a king size High Voltage tandem Van de'Graaff accelerator. The main domains of application of the thermal neutron activation analysis are: geology and mining, processing of materials, environment and biology, achaeology. Epithermal neutron activation analysis has been used for determination of uranium and thorium in ores with high Th/U ratios or high rare earth contents. One low energy accelerator, used as 14.1 Mev neutron source, is provided with special equipmen for oxigen and low mass elements determination. An useful alternating way to support fast neutron activation analysis is an accurate theoretical description of the fast neutron induced reactions based on the statistical model (Hauser-Feubach STAPRE code) and the preequilibrium decay geometry dependent model. A gravitational sample changer has been installed at the end of a beam line of the Cyclotron, which enables to perform charged particles activation analysis for protein determination in grains

  19. Activation analysis in Greece

    International Nuclear Information System (INIS)

    Grimanis, A.P.

    1985-01-01

    A review of research and development on NAA as well as examples of applications of this method are presented, taken from work carried out over the last 21 years at the Radioanalytical Laboratory of the Department of Chemistry in the Greek Nuclear Research Center ''Demokritos''. Improved and faster radiochemical NAA methods have been developed for the determination of Au, Ni, Cl, As, Cu, U, Cr, Eu, Hg and Mo in several materials, for the simultaneous determination of Br and I; Mg, Sr and Ni; As and Cu; As, Sb and Hg; Mn, Sr and Ba; Cd and Zn; Se and As; Mo and Cr in biological materials. Instrumental NAA methods have also been developed for the determination of Ag, Cl and Na in lake waters, Al, Ca, Mg and V in wines, 7 trace elements in biological materials, 17 trace elements in sediments and 20 minor and trace elements in ceramics. A comprehensive computer program for routine activation analysis using Ge(Li) detectors have been worked out. A rather extended charged-particle activation analysis program is carried out for the last 10 years, including particle induced X-ray emission (PIXE) analysis, particle induced prompt gamma-ray emission analysis (PIGE), other nuclear reactions and proton activation analysis. A special neutron activation method, the delayed fission neutron counting method is used for the analysis of fissionable elements, as U, Th, Pu, in samples of the whole nuclear fuel cycle including geological, enriched and nuclear safeguards samples

  20. Environmental pollution study around a large industrial area near Cairo, Egypt

    International Nuclear Information System (INIS)

    Abdel-Halim, A.S.

    2003-01-01

    Neutron activation analysis is one of the most extensively used methods for environmental studies due to its high sensitivity, precision, versatility and multielemental character. Cement factories at Helwan, south of Cairo, contribute substantially to environmental pollution. Determination of minor and trace-elements in dust particulates from the cement industrial areas has been performed to assess the air quality from an environmental and human health point of view. Soil-7 standard reference material from IAEA and SRM-1571 from NBS were used for quality assurance testing. The data obtained indicate there is an indication that the pollution could be hazardous to people living in and around the area surveyed. (author)

  1. INAA of airborne particulate matter collected in Bangkok 2002-2004

    International Nuclear Information System (INIS)

    Chueinta, W.; Bunprapob, S.; Tedthong, S.

    2006-01-01

    This paper presents the summary report of the monitoring study on ambient air quality in Bangkok metropolis and its boundary covering the period from 2002 to 2004. The work performed included sampling of fine and coarse fractions of particulate matter at the sites representing urban and suburban areas; measurement of particle mass concentration and elemental concentration; and data interpretation. Instrumental neutron activation by use of research reactor facilities at Office of Atoms for Peace was carried out for multielemental analysis of all filter samples collected. Twenty elements were determined. The database of the three consecutive years are summarized and reviewed in this paper. (author)

  2. Charged-particle activation analysis

    International Nuclear Information System (INIS)

    Schweikert, E.A.

    1978-01-01

    The paper discusses the methodology and application of nuclear activation with ion beams (1 9 via 16 O( 3 He,p) 18 F, 12 C( 3 He,α) 11 C and 14 N(p,α) 11 C respectively. Recently, triton activation has been shown to be inherently still superior to 3 He activation for the determination of oxygen [ 16 O( 3 H,n) 18 F]. Lithium, boron, carbon and sulphur can be detected rapidly, nondestructively and with high sensitivity (approximately 0.25ppm for Li and B) via ''quasi-prompt'' activation based on the detection of short-lived, high-energy beta emitters (10ms 1 H( 7 Li,n) 7 Be for example. Nondestructive multielement analysis: Proton activation has the inherent potential for meeting requirements of broad elemental coverage, sensitivity (ppm and sub-ppm range) and selectivity. Up to 30 elements have been determined in Al, Co, Ag, Nb, Rh, Ta and biological samples, using 12-MeV proton activation followed by gamma-ray spectrometry. These capabilities are further enhanced with the counting of X-ray emitters, 28 elements (26 9 ) and accuracy using proton activation. 204 Pb/ 206 Pb ratios can also be determined with a relative precision of a few per cent. Although charged-particle activation analysis is a well-established trace analysis technique, broad potential capabilities remain to be explored, e.g. those arising from ultrashort-lived nuclides, heavy ion interactions and the combination of delayed and prompt methods. (author)

  3. Forensic neutron activation analysis

    International Nuclear Information System (INIS)

    Kishi, T.

    1987-01-01

    The progress of forensic neutron activation analysis (FNAA) in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences (e.g., paints, metal fragments, plastics and inks) and drug sample differentiation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author) 14 refs

  4. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    International Nuclear Information System (INIS)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J.; Dziadowicz, M.; Kopeć, E.; Majewska, U.; Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I.; Wudarczyk-Moćko, J.; Góźdź, S.

    2015-01-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  5. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Dziadowicz, M.; Kopeć, E. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Majewska, U. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Wudarczyk-Moćko, J. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Góźdź, S. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Institute of Public Health, Jan Kochanowski University, IX Wieków Kielc 19, 25-317 Kielce (Poland)

    2015-12-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  6. Multielemental analysis of IAEA intercomparison standard Hay Powder, V-10 and some edible plant leaves by neutron activation. [Br,Ce,Cl,Cr,Cu,Fe,Ga,Hg,K,La,Mn,Mo,Na,P,Sc,Zn

    Energy Technology Data Exchange (ETDEWEB)

    Samudralwar, D L; Wankhade, H K; Garg, A N

    1987-12-01

    Instrumental neutron activation analysis was employed for the multielement determination of an IAEA intercomparison standard Hay Powder, V-10 and some edible plant leaves consumed in India. The samples were irradiated with thermal neutrons at a flux approx. = 10/sup 12/ n x cm/sup -2/ x s/sup -1/ in a reactor for 5 minutes, 1, 2, 5, 10 and 15 hours and counted by high resolution ..gamma..-ray spectrometry. Nearly 18 elements were determined. Good agreement is observed for most of the elements in several NBS standards and the proposed CRM V-10. Some edible vegetable plant leaves were also analyzed. (author) 32 refs.; 3 tabs.

  7. Simple procedure for nutrient analysis of coffee plant with energy dispersive X-ray fluorescence spectrometry (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Tezotto, Tiago; Favarin, Jose Laercio; Neto, Ana Paula; Azevedo, Ricardo Antunes, E-mail: tiago.tezotto@usp.br [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil); Gratao, Priscila Lupino [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP/ FCAV), Jaboticabal, SP (Brazil). Dept. de Biologia Aplicada a Agropecuaria; Mazzafera, Paulo [Universidade Estadual de Campinas (UNICAMP/IB), SP (Brazil). Dept. Biologia Vegetal

    2013-07-15

    Nutrient analysis is used to estimate nutrient content of crop plants to manage fertilizer application for sustained crop production. Direct solid analysis of agricultural and environmental samples by energy dispersive X-ray fluorescence spectrometry (EDXRF) was chosen as alternative technique to evaluate the simultaneous multielemental quantification of the most important essential elements in coffee (Coffea arabica L.) plants. Inductively coupled plasma atomic emission spectrometry and certified reference materials made from leaves were used to calibrate and check the trueness of EDXRF method for the determination of the concentration of several nutrients in coffee leaves and branches. Fluorescence spectrometry proved to be advantageous and presented low cost as loose powder samples could be used. Samples collected from a field experiment where coffee plants were treated with excess of Ni and Zn were used to verify the practical application of the method. Good relationships were achieved between certified values and data obtained by EDXRF, with recoveries ranging from 82 to 117 %.(author)

  8. Neutron activation analysis of biological substances

    International Nuclear Information System (INIS)

    Ordogh, M.

    1978-08-01

    A Bowen cabbage sample was used as a reference material for the neutron activation studies, and the method was checked by the analysis of other biological substances (blood or serum etc.). For nondestructive measurements also some non-trace elements were determined in order to decide whether the activation analysis is a useful means for such measurements. The new activation analysis procedure was used for biomedical studies as, e.g., for trace element determination in body fluids, and for the analysis of inorganic components in air samples. (R.P.)

  9. Evaluation of nuclear reactor based activation analysis techniques

    International Nuclear Information System (INIS)

    Obrusnik, I.; Kucera, J.

    1977-09-01

    A survey is presented of the basic types of activation analysis applied in environmental control. Reactor neutron activation analysis is described (including the reactor as a neutron source, sample activation in the reactor, methodology of neutron activation analysis, sample transport into the reactor and sample packaging after irradiation, instrumental activation analysis with radiochemical separation, data measurement and evaluation, sampling and sample preparation). Sources of environmental contamination with trace elements, sampling and sample analysis by neutron activation are described. The analysis is described of soils, waters and biological materials. Methods are shown of evaluating neutron activation analysis results and of their interpretation for purposes of environmental control. (J.B.)

  10. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Villot-Kadri, M.; Ismaël, A.; Gallou, G. [IVEA Solution, Centre Scientifique d' Orsay, Bât 503, 91400 Orsay (France); Michel, K.; Bruyère, D.; Laperche, V. [BRGM, Service Métrologie, Monitoring et Analyse, 3 avenue Claude Guillemin, B.P 36009, 45060 Orléans Cedex (France); Canioni, L. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Bousquet, B., E-mail: bruno.bousquet@u-bordeaux1.fr [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France)

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced.

  11. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    El Haddad, J.; Villot-Kadri, M.; Ismaël, A.; Gallou, G.; Michel, K.; Bruyère, D.; Laperche, V.; Canioni, L.; Bousquet, B.

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced

  12. The trace element analysis of ancient Indian coins using proton induced x-ray emission (PIXE) technique

    International Nuclear Information System (INIS)

    PURI, N.K.; HAJIVALIEI, M.; BEDI, S.C.; SINGH, N.; GOVIL, I.M.; GARG, M.L.; HANDA, D.K.; GOVIL, K.L.; ROUT, B.; VIJAYAN, V.

    2004-01-01

    Elemental analysis of ancient Indian coins viz. thirty-three punched marked coins (6 th century B.C.), fifty-nine coins belonging to Kusanas (78-250 A.D) and twenty-five coins belonging to medieval period (11 th -14 th century A.D), from India have been analysed using Proton Induced X-ray Emission (PIXE) technique. The elements namely S, Ca, Fe, Ag, Cu, Ni and Pb were detected in most of the punch-marked coins while elements namely S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, As and Zn were detected in most of the Kusanas coins and the S, Ca, Fe, Cu, Ag, Sn, Pb were detected in 11 th -14 th century A.D. coins. Based on the elemental analysis different hypotheses put forward in the earlier literature were examined. This is the first attempt where reasonable number of ancient coins belonging to different periods were analysed by modern non destructive multi-elemental technique such as PIXE and has put the importance of the elemental analysis of ancient Indian coins in the proper perspective

  13. Analysis of Precision of Activation Analysis Method

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Nørgaard, K.

    1973-01-01

    The precision of an activation-analysis method prescribes the estimation of the precision of a single analytical result. The adequacy of these estimates to account for the observed variation between duplicate results from the analysis of different samples and materials, is tested by the statistic T...

  14. Application of neutron activation analysis to the determination of total mercury and other elements of interest in soil and sediment samples from Serra do Navio and Vila Nova River Basin, Amapa, Brazil

    International Nuclear Information System (INIS)

    Goncalves, Cristina

    1997-01-01

    work were compared to those from other Brazilian regions, where the gold mining activities are being carried out, releasing this metal to the environment. To the multielemental results, it was applied Varimax rotation factorial analysis to verify geochemistry signature of the soils and sediments from both studied regions, besides Pearson similarity correlation test application and comparison to average values of terrestrial crust. (author)

  15. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  16. Total reflection X-ray fluorescence as a tool for food screening

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  17. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    International Nuclear Information System (INIS)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-01-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  18. {sup 14}C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Energy Technology Data Exchange (ETDEWEB)

    Santos Arévalo, Francisco-Javier, E-mail: fj.santos@csic.es; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-15

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  19. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Science.gov (United States)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  20. Proceedings of national seminar neutron activation analysis

    International Nuclear Information System (INIS)

    Agus Taftazani; Muhayatun Santoso; Budi Haryanto; Khatarina Oginawati

    2010-11-01

    Proceedings of national seminar neutron activation analysis in 2010 with the theme of the Role of Nuclear Analytical Techniques in the Field of Environment, Health and Industry. The seminar was organized by Indonesians Neutron Activation Analysis and BATAN Forum. These proceedings contain the result of environmental research in BATAN, universities and institutions associated with the application on neutron activation analysis technique. The purpose of these proceedings was as a useful source of information to spur research and development of activation analysis applications in various fields for the Indonesian welfare. There are 40 articles. (PPIKSN).

  1. Neutron activation analysis

    International Nuclear Information System (INIS)

    Taure, I.; Riekstina, D.; Veveris, O.

    2004-01-01

    Neutron activation analysis (NAA) in Latvia began to develop after 1961 when nuclear reactor in Salaspils started to work. It provided a powerful neuron source, which is necessary for this analytical method. In 1963 at Institute of Physics of the Latvian Academy of Sciences the Laboratory of Neutron Activation Analysis was formed. At the first stage of development the main tasks were of theoretical and technical aspects of NAA. Later the NAA was used to solve problems in technology, biology, and medicine. In the beginning of the 80-ties more attention was focussed to the use of NAA in the environmental research. Environmental problems stayed the main task till the closing the nuclear reactor in Salaspils in 1998 that ceased the main the existence of the laboratory and of NAA, this significant and powerful analytical method in Latvia and Baltic in general. (authors)

  2. Utilization of chemical derivatives in activation analysis

    International Nuclear Information System (INIS)

    Ehmann, W.D.

    1990-01-01

    Derivative activation analysis (DAA) is a method to enhance the sensitivity of nuclear activation analysis for the more elusive elements. It may also allow a degree of chemical speciation for the element of interest. DAA uses a preirradiation chemical reaction on the sample to initiate the formation of, or an exchange with, a chemical complex which contains a surrogate element, M. As a result, the amount of the element or the chemical species to be determined, X, is now represented by measurement of the amount of the surrogate element, M, that is made part of, or released by the complex species. The surrogate element is selected for its superior properties for nuclear activation analysis and the absence of interference reaction in its final determination by instrumental neutron activation analysis (INAA) after some preconcentration or separation chemistry. Published DAA studies have been limited to neutron activation analysis. DAA can offer the analyst some important advantages. It can determine elements, functional groups, or chemical species which cannot be determined directly by INAA, fast neutron activation analysis (FNAA), prompt gamma neutron activation analysis (PGNAA), or charged particle activation analysis (CPAA) procedures. When compared with conventional RNAA, there are fewer precautions with respect to handling of intensely radioactive samples, since the chemistry is done before the irradiation. The preirradiation chemistry may also eliminate many interferences that might occur in INAA and, through use of an appropriate surrogate element, can place the analytical gamma-ray line in an interference-free region of the gamma-ray spectrum

  3. Neutron activation analysis-comparative (NAAC)

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1979-01-01

    A software system for the reduction of comparative neutron activation analysis data is presented. Libraries are constructed to contain the elemental composition and isotopic nuclear data of an unlimited number of standards. Ratios to unknown sample data are performed by standard calibrations. Interfering peak corrections, second-order activation-product corrections, and deconvolution of multiplets are applied automatically. Passive gamma-energy analysis can be performed with the same software. 3 figures

  4. Extraction of metal ions using chemically modified silica gel: a PIXE analysis.

    Science.gov (United States)

    Jal, P K; Dutta, R K; Sudarshan, M; Saha, A; Bhattacharyya, S N; Chintalapudi, S N; K Mishra, B

    2001-08-30

    Organic ligand with carboxyhydrazide functional group was immobilised on the surface of silica gel and the metal binding capacity of the ligand-embedded silica was investigated. The functional group was covalently bonded to the silica matrix through a spacer of methylene groups by sequential reactions of silica gel with dibromobutane, malonic ester and hydrazine in different media. Surface area value of the modified silica was determined. The changes in surface area were correlated with the structural change of the silica surface due to chemical modifications. A mixture solution of metal ions [K(I),Cr(III),Co(II),Ni(II),Cu(II),Zn(II),Hg(II) and U(VI)] was treated with the ligand-embedded silica in 10(-3) M aqueous solution. The measurement of metal extraction capacity of the silica based ligand was done by multielemental analysis of the metal complexes thus formed by using Proton Induced X-ray Emission (PIXE) technique.

  5. Activation analysis in Europe: present and future perspectives

    International Nuclear Information System (INIS)

    De Corte, F.; Hoste, J.

    1984-01-01

    A survey is given of the present-day European contribution to activation analysis, covering neutron activation analysis (NAA), charged particle activation analysis (CPAA) and photon activation analysis (PAA). Attention is paid to the available irradiation facilities, in particular nuclear reactors, cyclotrons and Van de Graaff accelerators, and linear electron accelerators. Mention is made of progress in fundamental fields, but the attention is especially focussed on practical applications: environmental, geochemical/cosmochemical, biological/medical, and high-purity materials. Eventually, the role of activation analysis in research projects of the Commission of the European Communities (CEC) and in the Reference Materials program of the Community Bureau of Reference (BCR) is emphasized

  6. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  7. Neutron activation analysis of high-purity iron in comparison with chemical analysis

    International Nuclear Information System (INIS)

    Kinomura, Atsushi; Horino, Yuji; Takaki, Seiichi; Abiko, Kenji

    2000-01-01

    Neutron activation analysis of iron samples of three different purity levels has been performed and compared with chemical analysis for 30 metallic and metalloid impurity elements. The concentration of As, Cl, Cu, Sb and V detected by neutron activation analysis was mostly in agreement with that obtained by chemical analysis. The sensitivity limits of neutron activation analysis of three kinds of iron samples were calculated and found to be reasonable compared with measured values or detection limits of chemical analysis; however, most of them were above the detection limits of chemical analysis. Graphite-shielded irradiation to suppress fast neutron reactions was effective for Mn analysis without decreasing sensitivity to the other impurity elements. (author)

  8. Activation analysis with small mobile reactors

    International Nuclear Information System (INIS)

    Chung, C.

    1990-01-01

    A small nuclear reactor (a low-power reactor without heat removal devices) usually has thermal power output under 100 W and an average in-core thermal neutron flux below 10 9 n/cm 2 s. Conventional activation analysis is restricted to determination of specific elements with large neutron capture cross sections in sizable samples. In-vivo prompt gamma activation analysis (IVPGAA) can be used for diagnosis of elemental composition of the human body, particularly the essential elements Ca, Cl, N, and P in the whole body, and toxic Cd and Hg in contaminated organs. In this chapter, activation analysis using an external neutron beam from the Tsing Hua Mobile Educational Reactor (THMER) for in vivo activation is described. Characteristics of the mobile reactor, in-vivo medical diagnosis, and radiation safety are emphasized. 17 refs, 12 figs, 3 tabs

  9. Multielemental analysis of soil samples from the Assin District of Central Region in Ghana using nuclear and related techniques

    International Nuclear Information System (INIS)

    Agyemang, O.

    2008-06-01

    Macronutrients, micronutrients, pH, salinity and moisture content were determined in soil samples from six farms in two farming towns in Assin North District in the Central Region of Ghana namely Assin Akonfudi and Assin Bereku. Soil samples were taken from cocoa farms, orange farms and palm oil plantations at three different depths. The nutrients determined were Primary macronutrients that was K, Secondary macronutrients that were Ca, Mg and Micronutrients that were, Cl, Co, Cu, Fe, Mn, Mo, Zn, Na and Se and Neutron Activation method and Atomic Absorption Spectrometry were used for the elemental analysis. The pHs were within the acidic range, ranging from 4.50-6.44. The top soil (0-5cm) had the higher pH followed by soil at the depth of 5-30cm and then soil at the depth of 30-40cm that is the pH decreased with depth. The salinity rather increased with depth ranging from 0.3l-2.98dS/m and the moisture content also ranged from 0.5-2.04%. For the soil samples taken from the cocoa farms, K recorded the highest concentration and Mo recorded the lowest concentration in the soil. For soil samples taken from orange farms, Ca recorded the highest concentration and Se recorded the lowest concentration in the soil and for soil samples taken from the palm oil plantations, Fe recorded the highest concentration and Mo recorded the lowest concentration in soil. The macronutrients ranged from 28591.19-6.49 mg/kg and the micronutrients ranged from <0.0004-20344.50 mg/kg. Soils in the cocoa farms were found to be more rich in nutrients and the soils in the palm oil plantations were found to be least rich in nutrients

  10. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  11. Analysis of ancient masterly pieces of work by means of X-ray fluorescence analysis by dispersion in the energy; Analisis de obras de arte antiguas mediante fluorescencia de rayos X por dispersion en la energia

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R.; Cappio B, C.; Brunetti, A. [Istituto di Matematica e Fisica, Universita di Sassari (Italy); Rosales, M.A. [INAOE, Tonantzintla, Puebla (Mexico); Castellano, A. [Dipartimento di Scienza dei Materiali, Universita di Lecce (Italy); Gigante, G.E. [Dipartimento di Fisica, Universita La Sapienza, Roma (Italy); Fiorini, C. [Dip. di Elettronica ed Informazione, Politecnico di Milano (Italy)

    2004-07-01

    Energy dispersive X-ray fluorescence (EDXRF) analysis has been widely used for the analysis of works of art because it is non-destructive, multi-elemental, simple to utilize, and relatively inexpensive. In the last few years, miniaturized and portable X-ray tubes and high-resolution semiconductor detectors have been developed. This progress allowed the design and construction of portable equipments that can be easily transported all over the world, for use in museums, excavations, etc. In this work, these portable systems will be described and their usefulness demonstrated in the analysis of objects of archaeological value. First, we present the analysis of a lot of gold prehispanic jewels from the Museo del Templo Mayor in Mexico City; in the second place we present the results of analysis of the golden altar of St. Ambrogio in Milan, which is considered one of the most important goldsmith's works ever realized and the gold pigments from the fresco 'The chapel of the Scrovegni' by Giotto. In the third place we give a brief account of Mycenaean and pre-Mycenaean gold objects from the Museum Benaki in Athens. Finally, the results of bulk nuragic copper based ingots from the nuragic village of St. Imbenia are presented. (Author) 19 refs., 5 tabs., 8 figs.

  12. Physico-chemical studies of laser-induced plasmas for quantitative analysis of materials in nuclear systems

    International Nuclear Information System (INIS)

    Saad, Rawad

    2014-01-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a multi-elemental analysis technique very well suited for analysis in hostile environments particularly in the nuclear industry. Quantitative measurements are frequently performed on liquid or solid samples but in some cases, atypical signal behaviors were observed in the LIBS experiment. To avoid or minimize any impact on measurement accuracy, it is necessary to improve the understanding of these phenomena. In the framework of a three-year PhD thesis, the objective was to study the chemical reactions occurring within laser-generated plasma in a LIBS analysis. Experiments on a model material (pure aluminum sample) highlighted the dynamics of molecular recombination according to different ambient gas. The temporal evolution of Al I atomic emission lines and molecular bands of AlO and AlN were studied. A collisional excitation effect was identified for a peculiar electronic energy level of aluminum in the case of a nitrogen atmosphere. This effect disappeared in air. The aluminum plasma was also imaged during its expansion under the different atmospheres in order to localize the areas in which the molecular recombination process takes place. Spectacular particle projections have been highlighted. (author) [fr

  13. Minimally-invasive Laser Ablation Inductively Coupled Plasma Mass Spectrometry analysis of model ancient copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Walaszek, Damian [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Senn, Marianne; Wichser, Adrian [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Faller, Markus [Laboratory for Jointing Technology and Corrosion, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Wagner, Barbara; Bulska, Ewa [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Ulrich, Andrea [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland)

    2014-09-01

    This work describes an evaluation of a strategy for multi-elemental analysis of typical ancient bronzes (copper, lead bronze and tin bronze) by means of laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS).The samples originating from archeological experiments on ancient metal smelting processes using direct reduction in a ‘bloomery’ furnace as well as historical casting techniques were investigated with the use of the previously proposed analytical procedure, including metallurgical observation and preliminary visual estimation of the homogeneity of the samples. The results of LA-ICPMS analysis were compared to the results of bulk composition obtained by X-ray fluorescence spectrometry (XRF) and by inductively coupled plasma mass spectrometry (ICPMS) after acid digestion. These results were coherent for most of the elements confirming the usefulness of the proposed analytical procedure, however the reliability of the quantitative information about the content of the most heterogeneously distributed elements was also discussed in more detail. - Highlights: • The previously proposed procedure was evaluated by analysis of model copper alloys. • The LA-ICPMS results were comparable to the obtained by means of XRF and ICPMS. • LA-ICPMS results indicated the usefulness of the proposed analytical procedure.

  14. Application of proton induced x-ray emission (PIXE) in estimation of trace metals entrapped in silica matrix

    International Nuclear Information System (INIS)

    Jal, P.K.; Patel, Sabita; Mishra, B.K.; Sudarshan, M.; Saha, A.

    2005-01-01

    Proton induced x-ray emission technique is used for multielemental analysis of metal ions adsorbed on nanosilica surface. At pH 3.5, silica traps uranium selectively from a mixture of solutions of 13 different metal ions viz., K(I), Ca(II), Fe(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Sr(II), Cd(II). Ba(II), Hg(II) and UO 2 (VI). (author)

  15. Multivariant analyses of trace element patterns for environmental tracking

    International Nuclear Information System (INIS)

    Jervis, R.E.; Ko, M.M.C.; Junliang Tian; Puling Liu

    1993-01-01

    Nuclear-based analytical techniques: INAA, PIXE and photon activation permit simultaneous multielemental determination of concentrations in environmental materials, which data are often found sufficiently precise and free of uncontrolled, random errors among the various elements such that the data sets can yield valuable information on elemental communality through multi-variant statistical 'factor' analysis. Characteristic factor patterns obtained in this way can provide clues to the likely sources in the environment of various components. Recent studies in three different environmental situations: solid waste incinerators , Chinese soils, and iron and steel industry, involving measurements of 30-35 elements, have yielded distinct elemental patterns or, environmental signatures, with factor loading coefficients ranging mostly in the ranges: 0.7-0.96. (author) 10 refs.; 2 figs.; 9 tabs

  16. Geographic authentication of Asian rice (Oryza sativa L.) using multi-elemental and stable isotopic data combined with multivariate analysis.

    Science.gov (United States)

    Chung, Ill-Min; Kim, Jae-Kwang; Lee, Kyoung-Jin; Park, Sung-Kyu; Lee, Ji-Hee; Son, Na-Young; Jin, Yong-Ik; Kim, Seung-Hyun

    2018-02-01

    Rice (Oryza sativa L.) is the world's third largest food crop after wheat and corn. Geographic authentication of rice has recently emerged asan important issue for enhancing human health via food safety and quality assurance. Here, we aimed to discriminate rice of six Asian countries through geographic authentication using combinations of elemental/isotopic composition analysis and chemometric techniques. Principal components analysis could distinguish samples cultivated from most countries, except for those cultivated in the Philippines and Japan. Furthermore, orthogonal projection to latent structure-discriminant analysis provided clear discrimination between rice cultivated in Korea and other countries. The major common variables responsible for differentiation in these models were δ 34 S, Mn, and Mg. Our findings contribute to understanding the variations of elemental and isotopic compositions in rice depending on geographic origins, and offer valuable insight into the control of fraudulent labeling regarding the geographic origins of rice traded among Asian countries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Application of neutron activation analysis

    International Nuclear Information System (INIS)

    Dybczynski, R.

    2001-01-01

    The physical basis and analytical possibilities of neutron activation analysis have been performed. The number of applications in material engineering, geology, cosmology, oncology, criminology, biology, agriculture, environment protection, archaeology, history of art and especially in chemical analysis have been presented. The place of the method among other methods of inorganic quantitative chemical analysis for trace elements determination has been discussed

  18. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  19. Neutron activation spectrometry and neutron activation analysis in analytical geochemistry

    International Nuclear Information System (INIS)

    Dulski, P.; Moeller, P.

    1975-07-01

    The present report is to show the geochemists who are interested in neutron activation spectrometry (NAS) and neutron activation analysis (NAA) which analytical possibilities these methods offer him. As a review of these analytical possibilities, a lieterature compolation is given which is subdivided into two groups: 1) rock (basic, intermediary, acid, sediments, soils and nuds, diverse minerals, tectites, meteorites and lunar material). 2) ore (Al, Au, Be, Cr, Cu, Mn, Mo, Fe, Pb, Pt, Sn, Ti, W, Zn, Zr, U and phosphate ore, polymetallic ores, fluorite, monazite and diverse ores). The applied methods as well as the determinable elements in the given materials can be got from the tables. On the whole, the literature evaluation carried out makes it clear that neutron activation spectrometry is a very useful multi-element method for the analysis of rocks. The analysis of ores, however, is subjected to great limitations. As rock analysis is very frequently of importance in prospecting for ore deposits, the NAS proves to be extremely useful for this very field of application. (orig./LH) [de

  20. Analysis of coal by neutron activation

    International Nuclear Information System (INIS)

    Burtner, D.R.

    1983-01-01

    The development of a thermal-neutron activation analysis procedure for determining elemental concentrations in whole coal samples, and the goal of combining this technique with other nuclear methods for determining a total mass balance in these and similar complex materials, is described. Problems of applying a fast-neutron activation analysis method for nitrogen are discussed, as well as an efficient procedure for drying and packaging coal samples. A thermal-neutron activation analysis (TNAA) procedure was developed for determining up to 27 elements in coal samples from the US, China, Nigeria, and Brazil. The comparator form of TNAA was applied, using a unique multielement standard, which contained 48 elements. The difference in net photopeak counts between sample and standard, due to γ-ray attenuation, was reduced by preparing this standard in an organic matrix, which simulates the composition and physical structure of the coal material. The simultaneous irradiation of several aliquots of this standard enabled high precision and accuracy to be attained. An accurate value for oxygen, determined by fast-neutron activation analysis, is used to correct for this effect in the nitrogen determination method

  1. Gamma activation analysis with microtron

    International Nuclear Information System (INIS)

    Fiderkiewicz, A.; Kierzek, J.; Parus, J.; Swiderska-Kowalczyk, M.; Wolski, W.; Zoltowski, T.

    1989-01-01

    The physical principles of gamma activation analysis, its capabilities as well as its application to analyse polymetallic ores with use of mean power microtron are presented. Limits of detection and determination for above twenty elements occurring in those ores with use of short- and longlived radioisotopes are specified. The work contains conception of construction of race-track microtron with electrons energy adjusted in 10-30 MeV range and with current not less than 20 μA. Besides the development of microtrons, the reason for choosing the race-track construction for gamma activation analysis is given. 69 refs., 35 figs., 5 tabs. (author)

  2. 7th international conference ''Modern trends in activation analysis''

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1987-01-01

    The conference was held on 23-27 June, 1986 in Copenhagen (DK) with the participation of specialists from 42 countries. 175 papers were submitted covering the wide field of applications of neutron activation analysis, from novel techniques to sample preparation, information processes and control, activation techniques, light element and rare earth element determination, ultratracer analysis, quality assurance, comparator methods, and reference materials. The poster session was mainly oriented to industrial applications of activation analysis, biological applications, in vivo use of neutron activation analysis, the applications of neutron activation analysis in environmental control, criminology, etc. (E.S.)

  3. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  4. Neutron activation, k0-- method, as a tool for Phytoremediation studies and reclamation of degraded areas

    International Nuclear Information System (INIS)

    Uemura, George; Menezes, Maria Angela de Barros C.

    2007-01-01

    Phytoremediation is a technology that can be considered as a relatively recent one, although it is based on knowledge that has been gathered and accumulated for a long time. One advantage of phytoremediation is its relatively low cost, but, as it must rely on plant growth, its results might be quite slow to be achieved, specially in countries with temperate climate, which is not the case of vast areas of Brazilian territory. One of the aims of phytoremediation is the search of plants that are hyperaccumulators, i.e., that are capable of accumulating pollutants and/or contaminants in high concentrations, of which the fern Pteris vittata is a fine example, considering arsenic accumulation. The possibilities of exploring Brazilian native flora for this purpose demand no further comments. The reclamation of degraded areas demands might not necessarily rely only on species and/or varieties that are hyperaccumulators, but also on taxa that are resistant to a given pollutant or a mixture of pollutants. In this case, a precise analysis of the environment is fundamental, specially to ascertain, for sure, that some toxic element is not present. In this work, species known to accumulate arsenic from Brazilian native flora like Indian mustard (Brassica juncea) and Mirabilis jalapa were grown and exposed to arsenic. After that, they were lyophilised and analysed by means of the k 0- standardization method using the TRIGA MARK I IPR-R1 reactor at CDTN/CNEN. Certified reference material were also analysed to verify the accuracy of the method. The advantages of neutron activation, k 0- method, a multi-elemental analysis technique, in phytoremediation and reclamation of degraded areas, are discussed in the present paper. (author)

  5. Nuclear power company activity based costing management analysis

    International Nuclear Information System (INIS)

    Xu Dan

    2012-01-01

    With Nuclear Energy Industry development, Nuclear Power Company has the continual promoting stress of inner management to the sustainable marketing operation development. In view of this, it is very imminence that Nuclear Power Company should promote the cost management levels and built the nuclear safety based lower cost competitive advantage. Activity based costing management (ABCM) transfer the cost management emphases from the 'product' to the 'activity' using the value chain analysis methods, cost driver analysis methods and so on. According to the analysis of the detail activities and the value chains, cancel the unnecessary activity, low down the resource consuming of the necessary activity, and manage the cost from the source, achieve the purpose of reducing cost, boosting efficiency and realizing the management value. It gets the conclusion from the detail analysis with the nuclear power company procedure and activity, and also with the selection to 'pieces analysis' of the important cost related project in the nuclear power company. The conclusion is that the activities of the nuclear power company has the obviously performance. It can use the management of ABC method. And with the management of the procedure and activity, it is helpful to realize the nuclear safety based low cost competitive advantage in the nuclear power company. (author)

  6. Automated activation-analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Garcia, S.R.; Denton, M.M.

    1982-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day

  7. Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2001-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  8. Photon activation analysis on building materials

    International Nuclear Information System (INIS)

    Schulze, D.; Heller, W.; Kupsch, H.

    1988-01-01

    With regard to the planned construction of a new microtron, first investigations on raw materials for the aerated concrete production have been done to clear up the possibilities of photon activation analysis (PAA). Irradiations have been partly carried out on linear accelerators with a self-developed moveable activation equipment. PAA results of qualitative and quantitative elemental analysis are described. The detection of chlorine is important for studying the oversalting processes in buildings. (author)

  9. Methods of charged-particle activation analysis

    International Nuclear Information System (INIS)

    Chaudhri, M. Anwar; Chaudhri, M. Nasir; Jabbar, Q.; Nadeem, Q.

    2006-01-01

    The accuracy of Chaudhri's method for charged-particle activation analysis published in J. Radioanal. Chem. (1977) v. 37 p. 243 has been further demonstrated by extensive calculations. The nuclear reactions 12 C(d,n) 13 N, 63 Cu( 3 He,p) 65 Zn, 107 Ag(α,n) 110 In and 208 Pb(d,p) 209 Pb, the cross sections of which were easily available, have been examined for the detection of 12 C, 63 Cu, 107 Ag and 208 Pb, respectively, in matrices of Cu, Zr and Pb, at the bombarding energies of 4 - 22 MeV. The 'standard' is assumed to be in a carbon matrix. It has been clearly demonstrated that Chaudhri's method, which makes the charged particle activation analysis as simple as neutron activation analysis, provides results which are almost identical to, or only about 1-2 % different, from the results obtained using the full 'Activity Equation' involving solving complex integrals. It is valid even when the difference in the average atomic weights of matrices of the standard and the sample is large. (author)

  10. Comparison between XRF and IBA techniques in analysis of fine aerosols collected in Rijeka, Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia); Mandić, Luka, E-mail: lukam@phy.uniri.hr [Department of Physics, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka (Croatia); Orlić, Ivica [Department of Physics, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka (Croatia); Stelcer, Eduard; Cohen, David D. [Institute for Environmental Research, Australian Nuclear Science and Technology Organisation, Kirrawee DC, NSW 2232 (Australia)

    2014-10-15

    The new system for energy dispersive X-ray fluorescence (EDXRF) analysis has been installed at the Laboratory for Elemental Micro-Analysis (LEMA) at the University of Rijeka. Currently the key application of this new XRF system is in the field of environmental science, i.e. in the analysis of fine airborne particles. In this work, results of initial multi-elemental analysis of PM{sub 2.5} fraction is reported for the first time in the region of Rijeka, Croatia. Sampling was performed at the Rijeka City center, during a continuous 9-day period in February/March 2012. All samples were collected on stretched Teflon filters in 12 h periods. To check the reliability of the new XRF system, results of XRF analysis are compared with the results obtained by the well-established Ion Beam Analysis (IBA) laboratory at Australian Nuclear Science and Technology Organisation (ANSTO). The concentrations of H, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Br and Pb were determined. In addition, black carbon was determined by Laser Integrating Plate Method (LIPM). Very good agreement between XRF and IBA techniques is obtained for all elements detected by both techniques. Elemental concentrations were correlated with the traffic volume and wind speed and direction. The summary of our findings is presented and discussed in this paper.

  11. Environmental application of elemental speciation analysis based on liquid or gas chromatography hyphenated to inductively coupled plasma mass spectrometry-A review

    International Nuclear Information System (INIS)

    Popp, Maximilian; Hann, Stephan; Koellensperger, Gunda

    2010-01-01

    In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing 'classic' elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.

  12. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1979-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other trace elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  13. Radioactivity analysis in niobium activation foils

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, G.E.

    1995-06-01

    The motivation for this study was to measure and analyze the activity of six (6) niobium (Nb) foils (the x-rays from an internal transition in Nb-93m) and apply this information with previously obtained activation foil data. The niobium data was used to determine the epithermal to MeV range for the neutron spectrum and fluence. The foil activation data was re-evaluated in a spectrum analysis code (STAY`SL) to provide new estimates of the exposure at the Los Alamos Spallation Radiation Effect Facility (LASREF). The activity of the niobium foils was measured and analyzed at the University of Missouri-Columbia (UMC) under the direction of Professor William Miller. The spectrum analysis was performed at the University of Missouri-Rolla (UMR) by Professor Gary Mueller.

  14. Analysis of heterogeneous gallstones using laser-induced breakdown spectroscopy (LIBS) and wavelength dispersive X-ray fluorescence (WD-XRF).

    Science.gov (United States)

    Jaswal, Brij Bir S; Kumar, Vinay; Sharma, Jitendra; Rai, Pradeep K; Gondal, Mohammed A; Gondal, Bilal; Singh, Vivek K

    2016-04-01

    Laser-induced breakdown spectroscopy (LIBS) is an emerging analytical technique with numerous advantages such as rapidity, multi-elemental analysis, no specific sample preparation requirements, non-destructiveness, and versatility. It has been proven to be a robust elemental analysis tool attracting interest because of being applied to a wide range of materials including biomaterials. In this paper, we have performed spectroscopic studies on gallstones which are heterogeneous in nature using LIBS and wavelength dispersive X-ray fluorescence (WD-XRF) techniques. It has been observed that the presence and relative concentrations of trace elements in different kind of gallstones (cholesterol and pigment gallstones) can easily be determined using LIBS technique. From the experiments carried out on gallstones for trace elemental mapping and detection, it was found that LIBS is a robust tool for such biomedical applications. The stone samples studied in the present paper were classified using the Fourier transform infrared (FTIR) spectroscopy. WD-XRF spectroscopy has been applied for the qualitative and quantitative analysis of major and trace elements present in the gallstone which was compared with the LIBS data. The results obtained in the present paper show interesting prospects for LIBS and WD-XRF to study cholelithiasis better.

  15. Insurer’s activity as object of economic analysis

    Directory of Open Access Journals (Sweden)

    O.O. Poplavskiy

    2015-12-01

    Full Text Available The article is devoted to the substantiation of theoretical fundamentals of insurer’s analysis and peculiarities of its implementation. The attention has been focused on the important role of economic analysis in economic science which is confirmed by its active use in research and practical orientation. The author summarizes the classification and principles of insurer’s activity analysis, supplements it with specific principles for insurer’s environment, publicity and risk-orientation which enable increasingly to take into account the peculiarities of insurance relations. The paper pays attention to the specification of elements of analysis and its key directions including the analysis of insurer’s financing, the analysis of insurance operations and the analysis of investment activity which will allow the effective functioning of risk management system.

  16. Heavy ion activation analysis

    International Nuclear Information System (INIS)

    Lass, B.D.; Roche, N.G.; Sanni, A.O.; Schweikert, E.A.; Ojo, J.F.

    1982-01-01

    A report on radioactivation with ion beams of 3 6 Li and 14 N is presented with some analytical applications: the determination of C via 12 C( 6 Li,αn) 13 N; the determination of Li and Be, using 14 N activation. Next, examples, with limitations in selectivity. The detection limits using a 1 μA h of activation irradiation are 5 ppm for C and 1 ppm for Li or Be. With 9 Be suitable for analytical applications are: sup(10,11)B( 9 Be,xn) 18 F and 14 N( 9 Be,αn) 18 F. Assuming a 1 μA h irradiation the detection limits for N and B are 1.5 ng and 0.5 ng, respectively, using a 7.8 MeV 9 Be beam. For activation with 12 C, experimental results with 12 MeV 12 C beam demonstrate that the beam is best suited for 7 Li analysis by the reaction 7 Li( 12 C,n) 18 F. The detection limit for a 1 μA h irradiation is 1 ng and the only other low Z elements activated are B and C. Finally, 12 C radioactivation was further combined with autoradiography for positional analysis. The spatial resolution of the technique was estimated to be 40 μm for an exposure corresponding to 6x10 5 disintegrations. As low as 10 -12 g of Li was readily detected by autoradiography. (author)

  17. Methodological developments and applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    2007-01-01

    The paper reviews the author's experience acquired and achievements made in methodological developments of neutron activation analysis (NAA) of mostly biological materials. These involve epithermal neutron activation analysis, radiochemical neutron activation analysis using both single- and multi-element separation procedures, use of various counting modes, and the development and use of the self-verification principle. The role of NAA in the detection of analytical errors is discussed and examples of applications of the procedures developed are given. (author)

  18. Analysis of some Egyptian cosmetic samples by fast neutron activation analysis

    International Nuclear Information System (INIS)

    Medhat, M.E.; Ali, M.A.; Hassan, M.F.

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. The concentrations of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis

  19. A provenance study of iron archaeological artefacts by Inductively Coupled Plasma-Mass Spectrometry multi-elemental analysis

    International Nuclear Information System (INIS)

    Desaulty, Anne-Marie; Mariet, Clarisse; Dillmann, Philippe; Joron, Jean Louis; Fluzin, Philippe

    2008-01-01

    Raw materials and wastes (i.e. ore, slag and laitier) from ironmaking archaeological sites have been analyzed in order to understand the behavior of the trace elements in the ancient ironmaking processes and to find the significant-most elements to characterize an iron making region. The ICP-MS (Inductively Coupled Plasma Mass Spectrometry) appears to be an excellent technique for this type of studies. The comparison between the ICP-MS results obtained with the Standard Addition method and the INAA (Instrumental Neutron Activation Analyses) results proved that Sc, Co, (Ni), Rb, Cs, Ba, La, Ce, Sm, Eu, Yb, Hf, Th, U contents in the ores, slag and laitiers, and Co and Ni contents in the cast iron can be successfully determined by ICP-MS after wet acid digestion (low detection limits, good sensitivity and precision). By using significant trace element pairs (Yb/Ce, Ce/Th, La/Sc, U/Th, Nb/Y) present in the ores, laitiers and slag, it is possible to discriminate different French ironmaking regions as the Pays de Bray, Lorraine and Pays d'Ouche. These results open the way to further studies on the provenance of iron objects. The comparison between the ICP-MS results obtained with the Standard Calibration Curves method and the INAA results shows that matrices rich in iron, affect the ICP-MS analyses by suppressing the analytes signal. Further studies are necessary to improve understanding matrix effects

  20. Analysis of Some Egyptian Cosmetic Samples by Fast Neutron Activation Analysis

    CERN Document Server

    Medhat, M E; Fayez-Hassan, M

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. In our work, the concentration of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe, were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis.

  1. Heavy metals analysis in fishes by the X-ray fluorescence method

    International Nuclear Information System (INIS)

    Perez Novara, Ana Ma.

    1986-04-01

    Among the sources of contamination in human beings we find ingestion of heavy metals. As it is common practice to pour industrial wastes in waters where fishes feed, some toxic elements present in water may pass to human beings through ingestion. It is therefore important to determine the concentrations of heavy metals present in fishes, mainly in those living in waters close to industrial zones or villages. Concentrations of heavy metals in tissue of fishes amount to ppm, hence making necessary the use of very sensitive analytical techniques which do not require a too complex preparation of the sample in order to avoid the loss or contamination of interesting elements of analysis while handling them, thus falsifying the results. The X-Ray Fluorescence method covers these requirements and is not destructive nor multi-elemental. The development of the technique of element analysis in fishes by X-Ray Fluorescence comprised several aspects. from sampling and storage to quantification, specially stressing the preparation of samples. The work was carried out with a Si-Li detector/monitor for solid state and associated electronic equipment. Cd-109 and Pu-238 sources were used to produce excitation, detection limits near 1 ppm were obtained in the majority of elements the technique attained for the analysis of this kind of samples fulfills the celerity, precision, accuracy, and sensitivity requirements. (author)

  2. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.; Bowman, W.W.; Zeh, C.W.

    1980-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program, which is sponsored and funded by the United States Department of Energy, Grand Junction Office. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  3. Activation analysis of air particulate matter

    International Nuclear Information System (INIS)

    Alian, A.; Sansoni, B.

    1988-11-01

    This review on activation analysis of air particulate matter is an extended and updated version of a review given by the same authors in 1985. The main part is aimed at the analytical scheme and refers to rules and techniques for sampling, sample and standard preparation, irradiation and counting procedures, as well as data processing, - evaluation, and - presentation. Additional chapters deal with relative and monostandard methods, the use of activation analysis for atmosphere samples in various localities, and level of toxic and other elements in the atmosphere. The review contains 190 references. (RB)

  4. Nuclear activation analysis work at Analytical Chemistry Division: an overview

    International Nuclear Information System (INIS)

    Verma, R.; Swain, K.K.; Remya Devi, P.S.; Dalvi, Aditi A.; Ajith, Nicy; Ghosh, M.; Chowdhury, D.P.; Datta, J.; Dasgupta, S.

    2016-04-01

    Nuclear activation analysis using neutron and charged particles is used routinely for analysis and research at Analytical Chemistry Division (ACD), Bhabha Atomic Research Centre (BARC). Neutron activation analysis at ACD, BARC, Mumbai, India has been pursued since late fifties using Apsara, CIRUS, Dhruva and Critical facility Research reactors, 239 Pu-Be neutron source and neutron generator. Instrumental, Radiochemical, Chemical and Derivative neutron activation analysis approaches are adopted depending on the analyte and the matrix. Large sample neutron activation analysis as well as k 0 -based internal monostandard neutron activation analysis is also used. Charged particle activation analysis at ACD, Variable Energy Cyclotron Centre (VECC), Kolkata started in late eighties and is being used for industrial applications and research. Proton, alpha, deuteron and heavy ion beams from 224 cm room temperature Variable Energy Cyclotron are used for determination of trace elements, measurement of excitation function, thin layer activation and preparation of endohedral fullerenes encapsulated with radioactive isotopes. Analytical Chemistry Division regularly participates in Inter and Intra laboratory comparison exercises conducted by various organizations including International Atomic Energy Agency (IAEA) and the results invariably include values obtained by neutron activation analysis. (author)

  5. Analysis of active piezoelectric energy harvester

    Directory of Open Access Journals (Sweden)

    Yiliang CUI

    2018-02-01

    Full Text Available Most of the existing piezoelectric traps are designed for a narrow frequency range of vibration, but the surrounding environment has a very wide frequency range, and the frequency may also be subject to change, causing the problem of difficult to achieve energy capture or capture inefficiency. In order to solve problem, a new T-type piezoelectric cantilever is proposed as a capture energy structure in the paper. To begin with the aspects of structural design and circuit design, the static analysis, modal analysis and resonance analysis of the structure are carried out and the natural frequency and excitation frequency of the device are analyzed. The design and calculation of the power consumption and the loss of the components of the circuit are analyzed by the simulation and verification of the active capture energy circuit, and the active and passive techniques are compared and analyzed, the simulation of the active capture circuit is verified by analyzing the power consumption of the circuit and the maximum power obtained by the active technology is 5 times of that of the passive technology. And then the voltage-controlled active boundary control method can be used for interface circuit design, taking the initiative to use each piezoelectric transduction cycle triggered by the electrical boundary conditions to effectively increase the input piezoelectric pump energy, and then increase output power. The way of utilizing the active trapping of piezoelectric materials is innovated, which has a positive effect on the development of piezoelectric traps.

  6. Multielemental analysis of samples from patients with dermatological pathologies using synchrotron radiation

    International Nuclear Information System (INIS)

    Soares, J.C.A.C.R.; Canellas, C.G.L.; Anjos, M.J.; Lopes, R.T.

    2014-01-01

    Using synchrotron radiation total X-ray fluorescence (SRTXRF) technique, the concentrations of trace elements were measured in four skin lesions: seborrheic keratosis, fibroepithelial polyp, cherry angioma and dermatosis papulosa nigra. The concentrations of P, S, K, Ca, Fe, Cu, Zn and Rb were evaluated in 62 pairs of lesions and healthy samples, each one having been collected from the same patient. The results revealed significant differences of P, Ca, K, Fe and Cu levels as well as a common trend in their variations between lesion and control samples among the skin diseases. This study revealed a powerful tool that can be useful for skin disorders research. The measurements were conducted at Brazilian National Synchrotron Light Laboratory (LNLS). - Highlights: • Concentrations of trace elements were measured and compared in four skin lesions. • The results revealed significant differences of P, Ca, K, Fe and Cu levels. • This study revealed a powerful tool that can be useful for skin disorders research

  7. Multielemental analysis of plant species together with their corresponding soils in egypt

    International Nuclear Information System (INIS)

    Abu Kaddra, S.A.; Zahran, N.F.; Eissa, H.S.

    2005-01-01

    Different locations in the Nuclear Research Center (NRC) at Inshas area and the area nearby (about 30 km radius) were selected for collecting the vegetation samples together with their corresponding soils. Instrumental Scan Electron Microscope-Energy Dispersive X-ray Spectrometer (SEM-EDS) technique was applied to the determination of major and minor elements that are present at relatively high concentrations, while trace elements that are present at extremely low concentrations were determined by using: Inductively Coupled Plasma -Mass Spectrometer (ICP-MS). Two groups of elements have been determined directly in both plants and their corresponding soils. The first group is the major and the minor elements (Ca, Mg, K, P, Na, Cl and S ),and the second group is the trace elements (B ,V ,Cr, Mn, Ni, Co, Cu, Zn, Se, Mo, Sr, Cs, Th, U, As, Hg, Pb, and Cd). The results were inspected and the relation between different concentrations in both grasses and corresponding soil were considered

  8. Neutron activation analysis of Etruscan pottery

    International Nuclear Information System (INIS)

    Whitehead, J.; Silverman, A.; Ouellet, C.G.; Clark, D.D.; Hossain, T.Z.

    1992-01-01

    Neutron activation analysis (NAA) has been widely used in archaeology for compositional analysis of pottery samples taken from sites of archaeological importance. Elemental profiles can determine the place of manufacture. At Cornell, samples from an Etruscan site near Siena, Italy, are being studied. The goal of this study is to compile a trace element concentration profile for a large number of samples. These profiles will be matched with an existing data bank in an attempt to understand the place of origin for these samples. The 500 kW TRIGA reactor at the Ward Laboratory is used to collect NAA data for these samples. Experiments were done to set a procedure for the neutron activation analysis with respect to sample preparation, selection of irradiation container, definition of activation and counting parameters and data reduction. Currently, we are able to analyze some 27 elements in samples of mass 500 mg with a single irradiation of 4 hours and two sequences of counting. Our sensitivity for many of the trace elements is better than 1 ppm by weight under the conditions chosen. In this talk, details of our procedure, including quality assurance as measured by NIST standard reference materials, will be discussed. In addition, preliminary results from data treatment using cluster analysis will be presented. (author)

  9. Specific classification of financial analysis of enterprise activity

    Directory of Open Access Journals (Sweden)

    Synkevych Nadiia I.

    2014-01-01

    Full Text Available Despite the fact that one can find a big variety of classifications of types of financial analysis of enterprise activity, which differ with their approach to classification and a number of classification features and their content, in modern scientific literature, their complex comparison and analysis of existing classification have not been done. This explains urgency of this study. The article studies classification of types of financial analysis of scientists and presents own approach to this problem. By the results of analysis the article improves and builds up a specific classification of financial analysis of enterprise activity and offers classification by the following features: objects, subjects, goals of study, automation level, time period of the analytical base, scope of study, organisation system, classification features of the subject, spatial belonging, sufficiency, information sources, periodicity, criterial base, method of data selection for analysis and time direction. All types of financial analysis significantly differ with their inherent properties and parameters depending on the goals of financial analysis. The developed specific classification provides subjects of financial analysis of enterprise activity with a possibility to identify a specific type of financial analysis, which would correctly meet the set goals.

  10. Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Galiová, M.; Kaiser, J.; Fortes, J. F.; Novotný, K.; Malina, R.; Prokeš, L.; Hrdlička, A.; Vaculovič, T.; Nývltová Fišáková, Miriam; Svoboda, Jiří; Kanický, V.; Laserna, J. J.

    2010-01-01

    Roč. 43, č. 13 (2010), C191-C199 ISSN 0003-6935 R&D Projects: GA AV ČR KJB800010701 Institutional research plan: CEZ:AV0Z80010507 Keywords : bear * multieelemental analysis * LIBS * LA-ICP-MS Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 1.703, year: 2010

  11. Automated activation-analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Hensley, W.K.; Denton, M.M.; Garcia, S.R.

    1981-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. The system and its mode of operation for a large reconnaissance survey are described

  12. Manganese contents of soils as determined by activation analysis

    International Nuclear Information System (INIS)

    El-Kholi, A.F.; Hamdy, A.A.; Al Metwally, A.I.; El-Damaty, A.H.

    1976-01-01

    The object of this investigation is to determine total manganese by means of neutron activation analysis and evaluate this technique in comparison with the corresponding data obtained by conventional chemical analysis. Data obtained revealed that the values of total manganese in calcareous soils obtained by both chemical analysis and that by neutron activation analysis were similar. Therefore, activation analysis could be recommended as a quick laboratory, less tedious, and time consuming method for the determination of Mn content in both soils and plants than the conventional chemical techniques due to its great specificity, sensitivity and simplicity. Statistical analysis showed that there is a significant correlation at 5% probability level between manganese content in Soybean plant and total manganese determined by activation and chemical analysis giving the evidence that in the case of those highly calcareous soils of low total manganese content this fraction has to be considered as far as available soil manganese is concerned

  13. Particulate matter and neutron activation analysis

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko

    2003-01-01

    In these years, economy of East Asian region is rapidly growing, and countries in this region are facing serious environmental problems. Neutron activation analysis is known as one of high-sensitive analytical method for multi elements. And it is a useful tool for environmental research, particularly for the study on atmospheric particulate matter that consists of various constituents. Elemental concentration represents status of air, such as emission of heavy metals from industries and municipal incinerators, transportation of soil derived elements more than thousands of kilometers, and so on. These monitoring data obtained by neutron activation analysis can be a cue to evaluate environment problems. Japanese government launched National Air Surveillance Network (NASN) employing neutron activation analysis in 1974, and the data has been accumulated at about twenty sampling sites. As a result of mitigation measure of air pollution sources, concentrations of elements that have anthropogenic sources decreased particularly at the beginning of the monitoring period. However, even now, concentrations of these anthropogenic elements reflect the characteristics of each sampling site, e.g. industrial/urban, rural, and remote. Soil derived elements have a seasonal variation because of the contribution of continental dust transported by strong westerly winds prevailing in winter and spring season. The health effects associated with trace elements in particulate matter have not been well characterized. However, there is increasing evidence that particulate air pollution, especially fine portion of particles in many different cities is associated with acute mortality. Neutron activation analysis is also expected to provide useful information to this new study field related to human exposures and health risk. (author)

  14. Building an applied activation analysis centre

    International Nuclear Information System (INIS)

    Bartosek, J.; Kasparec, I.; Masek, J.

    1972-01-01

    Requirements are defined and all available background material is reported and discussed for the building up of a centre of applied activation analysis in Czechoslovakia. A detailed analysis of potential users and the centre's envisaged availability is also presented as part of the submitted study. A brief economic analysis is annexed. The study covers the situation up to the end of 1972. (J.K.)

  15. Neutron activation analysis in archaeological chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Harbottle, G [Brookhaven National Lab., Upton, NY (United States)

    1990-01-01

    There is a long history of the application of chemical analysis to archaeological problems, extending to the last years of the 18th century. The nuclear-age technique of neutron activation analysis, permitting the simultaneous, sensitive, non-destructive estimation of many elements in an archaeological specimen, has found wide application. Important advances have been made, using this technique, in locating the origins of archaeological artifacts such as ceramics, metals, obsidian and semiprecious stones, among other articles of ancient ritual and commerce. In addition, the technique of neutron activation analysis has proved to be almost ideal in studies tracing the development of ancient technologies such as glass-making and smelting. In the future, the development of data banks of analyses of archaeological materials should provide an excellent new tool in studies of prehistory.

  16. Neutron activation analysis in archaeological chemistry

    International Nuclear Information System (INIS)

    Harbottle, G.

    1990-01-01

    There is a long history of the application of chemical analysis to archaeological problems, extending to the last years of the 18th century. The nuclear-age technique of neutron activation analysis, permitting the simultaneous, sensitive, non-destructive estimation of many elements in an archaeological specimen, has found wide application. Important advantages have been made, using this technique, in locating the origins of archaeological artifacts such as ceramics, metals, obsidian and semiprecious stones, among other articles of ancient ritual and commerce. In addition, the technique of neutron activation analysis has proved to be almost ideal in studies tracing the development of ancient technologies such as glass-making and smelting. In the future, the development of data banks of analyses of archaeological materials should provide an excellent new tool in studies of prehistory. (orig.)

  17. Activation Analysis of Aluminium

    Energy Technology Data Exchange (ETDEWEB)

    Brune, Dag

    1961-01-15

    An analysis of pure aluminium alloyed with magnesium was per- formed by means of gamma spectrometry , Chemical separations were not employed. The isotopes to be determined were obtained in conditions of optimum activity by suitably choosing the time of irradiation and decay. The following elements were detected and measured quantitatively: Iron, zinc, copper, gallium, manganese, chromium, scandium and hafnium.

  18. TXRF analysis of trace metals in thin silicon nitride films

    International Nuclear Information System (INIS)

    Vereecke, G.; Arnauts, S.; Verstraeten, K.; Schaekers, M.; Heyrts, M.M.

    2000-01-01

    As critical dimensions of integrated circuits continue to decrease, high dielectric constant materials such as silicon nitride are being considered to replace silicon dioxide in capacitors and transistors. The achievement of low levels of metal contamination in these layers is critical for high performance and reliability. Existing methods of quantitative analysis of trace metals in silicon nitride require high amounts of sample (from about 0.1 to 1 g, compared to a mass of 0.2 mg for a 2 nm thick film on a 8'' silicon wafer), and involve digestion steps not applicable to films on wafers or non-standard techniques such as neutron activation analysis. A novel approach has recently been developed to analyze trace metals in thin films with analytical techniques currently used in the semiconductor industry. Sample preparation consists of three steps: (1) decomposition of the silicon nitride matrix by moist HF condensed at the wafer surface to form ammonium fluosilicate. (2) vaporization of the fluosilicate by a short heat treatment at 300 o C. (3) collection of contaminants by scanning the wafer surface with a solution droplet (VPD-DSC procedure). The determination of trace metals is performed by drying the droplet on the wafer and by analyzing the residue by TXRF, as it offers the advantages of multi-elemental analysis with no dilution of the sample. The lower limits of detection for metals in 2 nm thick films on 8'' silicon wafers range from about 10 to 200 ng/g. The present study will focus on the matrix effects and the possible loss of analyte associated with the evaporation of the fluosilicate salt, in relation with the accuracy and the reproducibility of the method. The benefits of using an internal standard will be assessed. Results will be presented from both model samples (ammonium fluoride contaminated with metallic salts) and real samples (silicon nitride films from a production tool). (author)

  19. Evaluation of relative comparator and k0-NAA for characterization of Aboriginal Australian ochre

    International Nuclear Information System (INIS)

    Popelka-Filcoff, R.S.; Lenehan, C.E.; Quinton, J.S.; Bennett, J.W.; Stopic, A.; Allan Pring; Keryn Walshe

    2012-01-01

    Ochre is a significant material in Aboriginal Australian cultural expression from ceremonial uses to its application on many types of artifacts. However, ochre is a complex material, with associated surrounding minerals potentially challenging the overall analysis. In recent literature several studies have attempted to characterize ochre by a variety of techniques to understand procurement and trade. However, ochre is difficult to differentiate on major elemental or mineralogical composition and requires a detailed analysis of its geochemical 'fingerprint'. Neutron activation analysis (NAA) provides the high sensitivity (sub-ppm), precision and accuracy in multi-elemental analysis required for ochre. The elements of interest for ochre generally include rare earth elements (REEs) and certain transition metal elements as well as arsenic and antimony. Data from relative comparator NAA (MURR, University of Missouri, USA) is compared with data from k 0 -NAA OPAL (ANSTO, Lucas Heights, Australia). A discussion of the two methods will be examined for their utility in 'fingerprinting' the provenance of ochre. The continuing importance of NAA to archaeometry will also be discussed. (author)

  20. Discrimination of wine from grape cultivated in Japan, imported wine, and others by multi-elemental analysis.

    Science.gov (United States)

    Shimizu, Hideaki; Akamatsu, Fumikazu; Kamada, Aya; Koyama, Kazuya; Okuda, Masaki; Fukuda, Hisashi; Iwashita, Kazuhiro; Goto-Yamamoto, Nami

    2018-04-01

    Differences in mineral concentrations were examined among three types of wine in the Japanese market place: Japan wine, imported wine, and domestically produced wine mainly from foreign ingredients (DWF), where Japan wine has been recently defined by the National Tax Agency as domestically produced wine from grapes cultivated in Japan. The main objective of this study was to examine the possibility of controlling the authenticity of Japan wine. The concentrations of 18 minerals (Li, B, Na, Mg, Si, P, S, K, Ca, Mn, Co, Ni, Ga, Rb, Sr, Mo, Ba, and Pb) in 214 wine samples were determined by inductively coupled-plasma mass spectrometry (ICP-MS) and ICP-atomic emission spectrometry (ICP-AES). In general, Japan wine had a higher concentration of potassium and lower concentrations of eight elements (Li, B, Na, Si, S, Co, Sr, and Pb) as compared with the other two groups of wine. Linear discriminant analysis (LDA) models based on concentrations of the 18 minerals facilitated the identification of three wine groups: Japan wine, imported wine, and DWF with a 91.1% classification score and 87.9% prediction score. In addition, an LDA model for discrimination of wine from four domestic geographic origins (Yamanashi, Nagano, Hokkaido, and Yamagata Prefectures) using 18 elements gave a classification score of 93.1% and a prediction score of 76.4%. In summary, we have shown that an LDA model based on mineral concentrations is useful for distinguishing Japan wine from other wine groups, and can contribute to classification of the four main domestic wine-producing regions of Japan. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  1. Activation analysis of biological materials at the Activation Analysis Centre

    International Nuclear Information System (INIS)

    Kukula, F.; Obrusnik, I.; Simkova, M.; Kucera, J.; Krivanek, M.

    1976-01-01

    A review is presented of the work of the Activation Analysis Centre of the Nuclear Research Institute for different fields of the Czechoslovak economy, aimed primarily at analyzing biological materials with the purpose of determining the contents of the so-called vital trace elements and of elements which already have a toxic effect on the organism in trace concentrations. Another important field of research is the path of trace elements from the environment to the human organism. A destructive method for the simultaneous determination of 12 trace elements in 11 kinds of human tissue has been studied. (Z.M.)

  2. Elemental mapping and quantitative analysis of Cu, Zn, and Fe in rat brain sections by laser ablation ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Brian [Dartmouth College, Departments of Earth Sciences and Chemistry, Hanover, NH (United States); Harper, Steve [University of Georgia, Savannah River Ecology Laboratory, Aiken, SC (United States); Smith, Laura; Flinn, Jane [George Mason University, Department of Psychology, Fairfax, VA (United States)

    2006-02-15

    This report details the application of laser ablation quadrupole ICP-MS for the (multi)elemental mapping of 100-{mu}m-thick sections of rat brain. The laser spot size used was 60 {mu}m, and the laser scan speed was 120 {mu}m s{sup -1}. The analysis was relatively rapid, allowing mapping of a whole brain thin section ({approx}1 cm{sup 2}) in about 2 h. Furthermore, the method was amenable to multi-element data collection including the physiologically important elements P and S and afforded sub {mu}g g{sup -1} detection limits for the important trace elements Cu and Zn. Calibrations were performed with pressed pellets of biological certified reference materials, and the elemental distributions and concentrations of Cu, Zn, and Fe were determined in whole rat brain sections. The distributions and concentration ranges for these elements were consistent with previous studies and demonstrate the utility of this technique for rapid mapping of brain thin sections. (orig.)

  3. Forensic neutron activation analysis - the Japanese scene

    International Nuclear Information System (INIS)

    Kishi, Tohru.

    1986-01-01

    The progress of forensic neutron activation analysis/FNAA/ in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences /e.g.,paints, metal fragments, plastics and inks/ and drug sample differenciation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author)

  4. Mutielemental concentration and physiological responses of Lavandula pedunculata growing in soils developed on different mine wastes.

    Science.gov (United States)

    Santos, Erika S; Abreu, Maria Manuela; Saraiva, Jorge A

    2016-06-01

    This study aimed to: i) evaluate the accumulation and translocation patterns of potentially hazardous elements into the Lavandula pedunculata and their influence in the concentrations of nutrients; and ii) compare some physiological responses associated with oxidative stress (concentration of chlorophylls (Chla, Chlb and total), carotenoids, and total protein) and several components involved in tolerance mechanisms (concentrations of proline and acid-soluble thiols and total/specific activity of catalase (CAT) and superoxide dismutase (SOD)), in plants growing in soils with a multielemental contamination and non-contaminated. Composite samples of soils, developed on mine wastes and/or host rocks, and L. pedunculata (roots and shoots) were collected in São Domingos mine (SE of Portugal) and in a reference area with non-contaminated soils, Corte do Pinto, with the same climatic conditions. São Domingos soils had high total concentrations of several hazardous elements (e.g. As and Pb) but their available fractions were small (mainly Lavandula pedunculata plants are able to survive in soils developed on different mine wastes with multielemental contamination and low fertility showing no symptoms (visible and physiological) of phytotoxicity or deficiency. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Activation analysis in the environment: Science and technology

    International Nuclear Information System (INIS)

    Lenihan, J.

    1989-01-01

    Science is disciplined curiosity. Activation analysis was created more than 50 yr ago by Hevesy's curiosity and Levi's experimental skill. Technology is the exploitation of machines and materials for the fulfillment of human needs or wants. The early history of neutron activation analysis (NAA) was greatly influenced by military requirements. Since then the technique has found applications in many disciplines, including materials science, medicine, archaeology, geochemistry, agriculture, and forensic science. More recently, neutron activation analysts, responding to increasing public interest and concern, have made distinctive contributions to the study of environmental problems. Activation analysis, though it uses some procedures derived from physics, is essentially a chemical technique. The chemical study of the environment may be reviewed under many headings; three are discussed here: 1. occupational medicine 2. health of the general public 3. environmental pollution

  6. A study of environmental analysis of urban river sediments using activation analysis

    International Nuclear Information System (INIS)

    Tanaka, Y.; Kuno, A.; Matsuo, M.

    2003-01-01

    Sediments of the Kitajukkengawa River (Sumida-ku, Tokyo, Japan) were analyzed by activation analyses. Concentrations of 36 elements for each sample were determined by instrumental neutron activation analysis (INAA) and neutron induced prompt gamma-ray analysis (PGA). Based on the correlation matrix between the elements in vertical distribution, principal component analysis (PCA) was performed. The degree of chemical weathering of silicate minerals was highest in the middle layer of the Kitajukkengawa River sediment and that adsorbed amount of trace metals such as Cd and Cr was increased along with chemical weathering. (author)

  7. Use of a synchrotron radiation x-ray microprobe for elemental analysis at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Gordon, B.M.

    1980-01-01

    The National Synchrotron Light Source (NSLS) is a facility consisting of a 700 MeV and a 2.5 GeV electron storage ring and dedicated to providing synchrotron radiation in the energy range from the vacuum ultraviolet to high energy x rays. Some of the properties of synchrotron radiation that contribute to its usefulness for x-ray fluorescence are: a continuous, tunable energy spectrum, strong collimation in the horizontal plane, high polarization in the storage ring plane, and relatively low energy deposition. The highest priority is for the development of an x-ray microprobe beam line capable of trace analysis in the parts per million range with spatial resolution as low as one micrometer. An eventual capability for bulk sample analysis is also planned with sensitivities in the more favorable cases beings low as 50 parts per billion in dry biological tissue. The microprobe technique has application to a variety of fields including the geological, medical, materials and environmental sciences. Examples of investigations include multielemental trace analysis across grain boundaries for the study of diffusion and cooling processes in geological and materials sciences samples; in leukocytes and other types of individual cells for studying the relationship between trace element concentrations and disease or nutrition; and in individual particles in air pollution samples

  8. Modeling activity patterns of wildlife using time-series analysis.

    Science.gov (United States)

    Zhang, Jindong; Hull, Vanessa; Ouyang, Zhiyun; He, Liang; Connor, Thomas; Yang, Hongbo; Huang, Jinyan; Zhou, Shiqiang; Zhang, Zejun; Zhou, Caiquan; Zhang, Hemin; Liu, Jianguo

    2017-04-01

    The study of wildlife activity patterns is an effective approach to understanding fundamental ecological and evolutionary processes. However, traditional statistical approaches used to conduct quantitative analysis have thus far had limited success in revealing underlying mechanisms driving activity patterns. Here, we combine wavelet analysis, a type of frequency-based time-series analysis, with high-resolution activity data from accelerometers embedded in GPS collars to explore the effects of internal states (e.g., pregnancy) and external factors (e.g., seasonal dynamics of resources and weather) on activity patterns of the endangered giant panda ( Ailuropoda melanoleuca ). Giant pandas exhibited higher frequency cycles during the winter when resources (e.g., water and forage) were relatively poor, as well as during spring, which includes the giant panda's mating season. During the summer and autumn when resources were abundant, pandas exhibited a regular activity pattern with activity peaks every 24 hr. A pregnant individual showed distinct differences in her activity pattern from other giant pandas for several months following parturition. These results indicate that animals adjust activity cycles to adapt to seasonal variation of the resources and unique physiological periods. Wavelet coherency analysis also verified the synchronization of giant panda activity level with air temperature and solar radiation at the 24-hr band. Our study also shows that wavelet analysis is an effective tool for analyzing high-resolution activity pattern data and its relationship to internal and external states, an approach that has the potential to inform wildlife conservation and management across species.

  9. Nuclear data for proton activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mukhammedov, S; Vasidov, A [Institute of Nuclear Physics of Academy of Sciences of Uzbekistan, 702132 Ulugbek, Tashkent (Uzbekistan); Comsan, M N.H. [Nuclear Research Centre, Inshas Cyclotron Facility, AEA 13759 Cairo (Egypt)

    2000-11-15

    The activation analysis with charged particles (ChPAA), as well as proton activation analysis (PAA), mainly requires separately irradiation of thick (thicker than the range of particles) samples and standard. Therefore for simplicity of determination of traces of chemical elements by instrumental PAA the absolute activity of the radionuclides must be known. Consequently we compilated data for nuclear decays (half life, radiation energy and intensity, type of decay, saturation factor), for nuclear reactions (excitation function, threshold energy, Q-value, yields of radionuclides), for the element under study (natural isotopic abundance of the nuclide, which yields the nuclear reaction considered, molar mass), stopping power of the irradiated material and the range of the particle that are used in the calculation of the absolute activity of the radionuclides and for the resolution of a nuclear interference problems of PAA. These data are tabulated. The tables of the radionuclides are presented in dependence on increasing atomic number and radiation energy as well as on methods of the radionuclide formation. The thick target yields of analytical radionuclides are presented versus particle energy.

  10. Nuclear data for proton activation analysis

    International Nuclear Information System (INIS)

    Mukhammedov, S.; Vasidov, A.; Comsan, M.N.H.

    2000-01-01

    The activation analysis with charged particles (ChPAA), as well as proton activation analysis (PAA), mainly requires separately irradiation of thick (thicker than the range of particles) samples and standard. Therefore for simplicity of determination of traces of chemical elements by instrumental PAA the absolute activity of the radionuclides must be known. Consequently we compilated data for nuclear decays (half life, radiation energy and intensity, type of decay, saturation factor), for nuclear reactions (excitation function, threshold energy, Q-value, yields of radionuclides), for the element under study (natural isotopic abundance of the nuclide, which yields the nuclear reaction considered, molar mass), stopping power of the irradiated material and the range of the particle that are used in the calculation of the absolute activity of the radionuclides and for the resolution of a nuclear interference problems of PAA. These data are tabulated. The tables of the radionuclides are presented in dependence on increasing atomic number and radiation energy as well as on methods of the radionuclide formation. The thick target yields of analytical radionuclides are presented versus particle energy

  11. Neutron activation, k{sub 0-}- method, as a tool for Phytoremediation studies and reclamation of degraded areas

    Energy Technology Data Exchange (ETDEWEB)

    Uemura, George; Menezes, Maria Angela de Barros C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mails: george@cdtn.br; menezes@cdtn.br

    2007-07-01

    Phytoremediation is a technology that can be considered as a relatively recent one, although it is based on knowledge that has been gathered and accumulated for a long time. One advantage of phytoremediation is its relatively low cost, but, as it must rely on plant growth, its results might be quite slow to be achieved, specially in countries with temperate climate, which is not the case of vast areas of Brazilian territory. One of the aims of phytoremediation is the search of plants that are hyperaccumulators, i.e., that are capable of accumulating pollutants and/or contaminants in high concentrations, of which the fern Pteris vittata is a fine example, considering arsenic accumulation. The possibilities of exploring Brazilian native flora for this purpose demand no further comments. The reclamation of degraded areas demands might not necessarily rely only on species and/or varieties that are hyperaccumulators, but also on taxa that are resistant to a given pollutant or a mixture of pollutants. In this case, a precise analysis of the environment is fundamental, specially to ascertain, for sure, that some toxic element is not present. In this work, species known to accumulate arsenic from Brazilian native flora like Indian mustard (Brassica juncea) and Mirabilis jalapa were grown and exposed to arsenic. After that, they were lyophilised and analysed by means of the k{sub 0-} standardization method using the TRIGA MARK I IPR-R1 reactor at CDTN/CNEN. Certified reference material were also analysed to verify the accuracy of the method. The advantages of neutron activation, k{sub 0-}method, a multi-elemental analysis technique, in phytoremediation and reclamation of degraded areas, are discussed in the present paper. (author)

  12. Neutron activation analysis of artefacts

    International Nuclear Information System (INIS)

    Mohd Suhaimi Hamzah; Shamsiah Abd Rahman

    2004-01-01

    The paper discussed the utilization of neutron activation analysis in this field. NAA, an analytical technique which analyzing the elements in the sample without any chemical treatment. It is sensitive and accurate. Archaeological objects i.e. ceramics, historical building materials, metals, etc can be analyze with this technique. The analysis results were presented in form of characterization of the artefacts in chemical profiles, which can present the information of the origin of the artefacts as well as it originality. (Author)

  13. Development of educational program for neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Ryel, Sung; Kang, Young Hwan; Lee, Kil Yong; Yeon, Yeon Yel; Cho, Seung Yeon

    2000-08-01

    This technical report is developed to apply an educational and training program for graduate student and analyst utilizing neutron activation analysis. The contents of guide book consists of five parts as follows; introduction, gamma-ray spectrometry and measurement statistics, its applications, to understand of comprehensive methodology and to utilize a relevant knowledge and information on neutron activation analysis

  14. Development of educational program for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Ryel, Sung; Kang, Young Hwan; Lee, Kil Yong; Yeon, Yeon Yel; Cho, Seung Yeon

    2000-08-01

    This technical report is developed to apply an educational and training program for graduate student and analyst utilizing neutron activation analysis. The contents of guide book consists of five parts as follows; introduction, gamma-ray spectrometry and measurement statistics, its applications, to understand of comprehensive methodology and to utilize a relevant knowledge and information on neutron activation analysis.

  15. Application of activation techniques to biological analysis

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1981-01-01

    Applications of activation analysis in the biological sciences are reviewed for the period of 1970 to 1979. The stages and characteristics of activation analysis are described, and its advantages and disadvantages enumerated. Most applications involve activation by thermal neutrons followed by either radiochemical or instrumental determination. Relatively little use has been made of activation by fast neutrons, photons, or charged particles. In vivo analyses are included, but those based on prompt gamma or x-ray emission are not. Major applications include studies of reference materials, and the elemental analysis of plants, marine biota, animal and human tissues, diets, and excreta. Relatively little use of it has been made in biochemistry, microbiology, and entomology, but it has become important in toxicology and environmental science. The elements most often determined are Ag, As, Au, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, Fe, Hg, I, K, Mn, Mo, Na, Rb, Sb, Sc, Se, and Zn, while few or no determinations of B, Be, Bi, Ga, Gd, Ge, H, In, Ir, Li, Nd, Os, Pd, Pr, Pt, Re, Rh, Ru, Te, Tl, or Y have been made in biological materials

  16. Conference on instrumental activation analysis - IAA 89

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1989-05-01

    The proceedings contain 40 abstracts of papers all of which have been incorporated in INIS. The papers were centred on the applications of radioanalytical methods, especialy on neutron activation analysis, X-ray fluorescence analysis, PIXE analysis and tracer techniques in biology, medicine and metallurgy, measuring instruments including microcomputers, and data processing methods. (J.P.)

  17. Nondestructive neutron activation analysis of mineral materials. III

    International Nuclear Information System (INIS)

    Randa, Z.; Benada, J.; Kuncir, J.; Vobecky, M.

    1979-01-01

    A description is presented of sampling, calibration standards, the method of activation and measurement, activation product identification, the respective nuclear reactions, interfering admixtures, and pre-activation operations. The analysis is described of sulphides, halogenides, oxides, sulphates, carbonates, phosphates, silicates, aluminosilicates, composite minerals containing lanthanides, rocks, tektites, meteors, and plant materials. The method allows determining mainly F, Mg, Al, Ti, V, Nb, Rh, and I which cannot be determined by long-term activation (LTA). It is more sensitive than LTA in determining Ca, Cu, In, and Dy. The analysis takes less time, irradiation and measurement are less costly. The main mineral components are quickly found. (M.K.)

  18. Multielemental nondestructive neutron activation analysis of Dy, Mn, Eu, Na, Ga, W, La and Sm involving cyclic irradiations with 252Cf

    International Nuclear Information System (INIS)

    Narkhede, S.S.; Turel, Z.R.

    1995-01-01

    Dy, Mn, Eu, Na, Ga, W, La and Sm respond very well to INAA technique because of their favourable nuclear properties such as high thermal neutron cross-section or abundance. In the present work a method has been developed for the determination of these elements employing cycle irradiation with 252 Cf thermal neutron source. Radioassaying of the irradiated sample and standard was done employing HPGe detector in conjunction with a PC based MCA units. (author). 2 tabs

  19. Studies in heavy ion activation analysis Pt. 4

    International Nuclear Information System (INIS)

    Lass, B.D.; Ojo, J.F.; Schweikert, E.A.

    1980-01-01

    The use of 7 MeV 6 Li + for heavy ion activation analysis was investigated. A survey of reactions, involving targets of lithium through oxygen inclusive, were studied for production of β + radioactivation products with half-lives of 10 1 -10 5 seconds. Specific activities for all reactions under the experimental conditions are reported and their use for analysis is assessed. (author)

  20. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Ka-Ngo Leung; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity. (author)

  1. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    Firestone, Richard B; English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Leung, Ka-Ngo; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents.1-3. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity

  2. Neutron activation analysis of geological material

    International Nuclear Information System (INIS)

    Greef, G.J.

    1977-05-01

    In neutron activation analysis the precision and accuracy of results are often misleading, since only the statistical errors which accompany the measuring of radioactivity are taken into consideration. Several other factors can, however, also influence precision and accuracy. It was found that a geological sample was contaminated with the construction material of the mill in which it had been pulverised. Several geometrical differences which could possibly play a role were also investigated. Impurities in the irradiation containers affect the determination of some elements in the samples; the contamination materials in quarts irradiation tubes were determined. The flux gradients which may effect the relative activities of the samples and standards were measured. Suitable standards are necessary to ensure accurate analyses of geological material. Available natural standards were critically evaluated and several methods were investigated by which synthetic standards may be prepared. In order to accurately determine gallium, lanthanum and samarium by means of neutron activation analysis, sodium first had to be removed. After irradiation the sample was dissolved in a mixture of acids and the soidium absorbed from the solution on a hydrated antimony pentoxide column. Gallium, lanthanum and samarium activities were measured by means of precision gamma-spectrometry

  3. Analysis by neutronic activation of the active principles of MIBI

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.T.; Moreno Bermudez, J.; Ribeiro Guevara, S.; Molina Insfran, J.; Perez Zayas, G.

    1997-01-01

    In the present job the obtained results are shown through the application of an analysis by neutronic activation, in their instrumental variant, for the determination of the elementary composition of three Cuban radiopharmaceuticals. (author) [es

  4. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  5. Physical basis for prompt-neutron activation analysis

    International Nuclear Information System (INIS)

    Chrien, R.E.

    1982-01-01

    The technique called prompt ν-ray neutron activation analysis has been applied to rapid materials analysis. The radiation following the neutron radiation capture is prompt in the sense that the nuclear decay time is on the order of 10 - 15 second, and thus the technique is not strictly activation, but should be called radiation neutron capture spectroscopy or neutron capture ν-ray spectroscopy. This paper reviews the following: sources and detectors, theory of radiative capture, nonstatistical capture, giant dipole resonance, fast neutron capture, and thermal neutron capture ν-ray spectra. 14 figures

  6. Study on neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Cho, Seung Yeon

    1993-01-01

    Environmental samples were analyzed quantitatively by neutron activation analysis using high resolution γ-ray spectrometry. The accuracy and precision of the method were checked by the analysis of reference materials, Urban Particulate Matter (NBS SRM 1648) and Coalfly ash (NBS SRM 1633a). Airborne particulates collected for 6 months with low volume air sampler at the outer area of Seoul were analyzed as the start of full scale airborne particulates research. We analyzed 19 trace elements from the samples and the NAA method was confirmed to be utilized for environmental pollution research. (Author)

  7. A new facility for rapid neutron activation analysis

    International Nuclear Information System (INIS)

    Zeisler, R.; Makarewicz, M.; Grass, F.; Casta, J.

    1996-01-01

    Many research groups have undertaken efforts on the utilization of short-lived nuclides in a broad spectrum of neutron activation analysis (NAA) applications. The advantages of these approaches are obvious because the information on the sample can be extracted more rapidly. In addition to its other advantages, NAA can become extremely competitive in price and analysis time. Nevertheless, NAA with short-lived nuclides has not gained broad popularity, perhaps because of some difficulties in accuracy and the availability of suitable irradiation facilities. This report discusses the ASTRA reactor for neutron activation analysis capabilities

  8. Neutron activation analysis for antimetabolites. [in food samples

    Science.gov (United States)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  9. Neutron activation analysis: principle and methods

    International Nuclear Information System (INIS)

    Reddy, A.V.R.; Acharya, R.

    2006-01-01

    Neutron activation analysis (NAA) is a powerful isotope specific nuclear analytical technique for simultaneous determination of elemental composition of major, minor and trace elements in diverse matrices. The technique is capable of yielding high analytical sensitivity and low detection limits (ppm to ppb). Due to high penetration power of neutrons and gamma rays, NAA experiences negligible matrix effects in the samples of different origins. Depending on the sample matrix and element of interest NAA technique is used non-destructively, known as instrumental neutron activation analysis (INAA), or through chemical NAA methods. The present article describes principle of NAA, different methods and gives a overview some applications in the fields like environment, biology, geology, material sciences, nuclear technology and forensic sciences. (author)

  10. Trace element analysis of common salt using neutron activation analysis

    International Nuclear Information System (INIS)

    Usman, K.

    1993-01-01

    Instrumental Fast Neutron Activation Analysis (IFNAA) technique has been used in the qualitative and quantitative determination of the impurity elements in common salt. Samples of the different types of common salt processed in Nigeria and some of those imported into the country were used. The type A711 KAMAN neutron generator and a high-purity Germanium (HpGe) gamma spectrometer available at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria has been used. The ORTEC ADCAM 100 Emulation Software (Maestro) was used in the qualitative measurement of the detected elements. The G.R.G Activation Analysis System by G. R. Gilmore, 1987, was used in the quantitative determination of the elements detected by relative method. Aluminium and arsenic were detected and measured

  11. Trace metal content in aspirin and women's cosmetics via proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Hichwa, B.P.; Pun, D.D.; Wang, D.

    1981-01-01

    A multielemental analysis to determine the trace metal content of generic and name-brand aspirins and name-brand lipsticks was done via proton induced x-ray (PIXE) measurements. The Hope College PIXE system is described as well as the target preparation methods. The trace metal content of twelve brands of aspirin and aspirin substitutes and fourteen brands of lipstick are reported. Detection limits for most elements are in the range of 100 parts per billion (ppb) to 10 parts per million

  12. Multi-elemental contamination and historic record in sediments from the Santos-Cubatao Estuarine System, Brazil

    International Nuclear Information System (INIS)

    Luiz-Silva, Wanilson; Machado, Wilson; Matos, Rosa H.R.

    2008-01-01

    This paper records for the first time the contamination history and identifies the sources of 38 elements in sediments from the Santos-Cubatao Estuarine System (SE Brazil), at one of the most industrialized areas in Latin America. The compositions of samples from a 260 cm long sediment core collected in the Morrao River estuary were determined by ICP-MS. Enrichment factors, principal component analysis, correlation matrixes, and the characterization of geochemical signatures permitted a consistent data evaluation. Contaminant elements such as Cr, Mn, Ni, Zn, Ga, Ag, Cd, Sn, Sb, Pb, and Bi were associated with steel plant-derived Fe concentrations, while Be, Ca, Sc, Co, Cu, Sr, Y, Zr, Nb, Hf, Ta, Th, and U were associated with fertilizer industry-derived P concentrations. An overlap of sedimentary Fe distribution and local steel plant production indicated that Fe is a reliable marker of the contamination history, allowing the estimation of sedimentation rates over a period of 45 years of industrial activities. (author)

  13. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Behera, P.R., E-mail: priyaranjan2004@gmail.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Nayak, P [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Barik, D.P., E-mail: barikdp@yahoo.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Rautray, T.R., E-mail: trrautray@gmail.co [Ion Beam Laboratory, Institute of Physics, Bhubaneswar 751013, Orissa (India); Thirunavoukkarasu, M [Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Chand, P.K., E-mail: pkchanduubot@yahoo.co.i [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India)

    2010-12-15

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  14. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    International Nuclear Information System (INIS)

    Behera, P.R.; Nayak, P.; Barik, D.P.; Rautray, T.R.; Thirunavoukkarasu, M.; Chand, P.K.

    2010-01-01

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  15. Neutron activation analysis of atmospheric aerosol

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1986-01-01

    Neutron activation analysis (NAA) is a modern analytical method well suited for the analysis of atmospheric aerosols. Particular steps of the NAA procedure and especially different types of aerosol sampling and sample preparation for analysis are discussed in detail. Several possible NAA techniques are described and the advantages of a purely instrumental technique with short and long irradiation are pointed out. Important performance characteristics of the NAA method such as precision, accuracy, sensitivity and detection limits are also discussed. Different applications of NAA in environmental studies are reviewed. (author)

  16. Analysis of some metallic elements and metalloids composition and relationships in parasol mushroom Macrolepiota procera.

    Science.gov (United States)

    Falandysz, Jerzy; Sapkota, Atindra; Dryżałowska, Anna; Mędyk, Małgorzata; Feng, Xinbin

    2017-06-01

    The aim of the study was to characterise the multi-elemental composition and associations between a group of 32 elements and 16 rare earth elements collected by mycelium from growing substrates and accumulated in fruiting bodies of Macrolepiota procera from 16 sites from the lowland areas of Poland. The elements were quantified by inductively coupled plasma quadrupole mass spectrometry using validated method. The correlation matrix obtained from a possible 48 × 16 data matrix has been used to examine if any association exits between 48 elements in mushrooms foraged from 16 sampling localizations by multivariate approach using principal component (PC) analysis. The model could explain up to 93% variability by eight factors for which an eigenvalue value was ≥1. Absolute values of the correlation coefficient were above 0.72 (significance at p < 0.05) for 43 elements. From a point of view by consumer, the absolute content of Cd, Hg, Pb in caps of M. procera collected from background (unpolluted) areas could be considered elevated while sporadic/occasional ingestion of this mushroom is considered safe. The multivariate functional analysis revealed on associated accumulation of many elements in this mushroom. M. procera seem to possess some features of a bio-indicative species for anthropogenic Pb but also for some geogenic metals.

  17. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  18. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  19. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  20. INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Kalinich

    1999-09-27

    Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be included as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.

  1. Molecular activation analysis for chemical species studies

    International Nuclear Information System (INIS)

    Chai Zhifang; Mao Xueying; Wang Yuqi; Sun Jingxin; Qian Qingfang; Hou Xiaolin; Zhang Peiqun; Chen Chunying; Feng Weiyu; Ding Wenjun; Li Xiaolin; Li Chunsheng; Dai Xiongxin

    2001-01-01

    The Molecular Activation Analysis (MAA) mainly refers to an activation analysis method that is able to provide information about the chemical species of elements in systems of interest, though its exact definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the bulk contents or concentrations are often insignificant for judging biological, environmental or geochemical effects of elements. In this paper, the features, methodology and limitation of MAA were outlined. Further, the up-to-date MAA progress made in our laboratory was introduced as well. (author)

  2. Recent applications of neutron activation analysis at Lucas Heights

    International Nuclear Information System (INIS)

    Fardy, J.J.

    1978-01-01

    The use of neutron activation analysis to determine key elemental distribution patterns in samples from both the energy industry and health science field is summarised. Instrumental neutron activation analysis has successfully measured simultaneously more than twenty elements in a sample of brown coal from Victoria, black coal from New South Wales and samples from the product stream of ACIRL's batch autoclave, solvent-refined, coal hydrogenation process. Four gallstones removed from the same gallbladder have been examined instrumentally by neutron activation analysis. A total of sixteen trace elements were detected with concentrations in the range 0.8 ng g -1 for gold to 7,800 μg g -1 for calcium

  3. Proton activation analysis at the Harvard Cyclotron Laboratory

    International Nuclear Information System (INIS)

    Sisterson, J.M.; Koehler, A.M.

    1984-01-01

    High-energy proton activation analysis (PAA), a simple non-destructive technique, has been developed for use as an adjunct to neutron activation analysis. Potential advantages of protons include the ability to achieve very precise localization of the activation volume over a pre-determined depth in the target. To demonstrate the versatility of PAA, results are reported on the measurement of the whole body calcium content in animals and on the determination of the Ca/P molar ratio in small quantities (<50 mg) of chemical and biological samples. The animal experiments demonstrate the ability to achieve a uniform irradiation over a large volume and utilizes large NaI crystals with a special chamber for uniform combined detection efficiency, where the Ca/P molar ratio determination requires a Ge/Li detector and analysis of the resulting gamma ray spectrum. The feasibility is being assessed of using proton beam activation of the eye to measure blood flow in the rabbit choroid, based on earlier work where it was used to measure blood in mouse skeletal tissue. 6 references, 7 figures, 4 tables

  4. Activation analysis by filtered neutrons. Preliminary investigation

    International Nuclear Information System (INIS)

    Skarnemark, G.; Rodinson, T.; Skaalberg, M.; Tokay, R.K.

    1986-01-01

    In order to investigate if measuring sensibility and precision by epithermal neutron activation analysis may be improved, different types of geological and biologic test samples were radiated. The test samples were enclosed in an extra filter of tungsten or sodium in order to reduce the flux of those neutrons that otherwise would induce interfering activity in the sample. The geological test samples consist of granites containing lanthanides which had been crushed in tung- sten carbide grinder. Normally such test samples show a interferins 1 87W-activity. By use of a tungsten filter the activity was reduced by up to 60%, which resulted in a considerable improvement of sensibility and precision of the measurement. The biologic test samples consisted of evaporated urine from patients treated with the cell poison cis-platinol. A reliable method to measure the platinum content has not existed so far. This method, however, enables platinum contents as low as about 0.1 ppm to be determined which is quite adequate. To sum up this preliminary study has demonstrated that activation analysis using filtered neutrons, correctly applied, is a satisfactory method of reducing interferences without complicated and time-consuming chemical separation procedures. (O.S.)

  5. Regional and global atmospheric aerosol studies using the ''Gent'' stacked filter unit sampler and other aerosol collectors, with multi-elemental analysis of the samples by nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Maenhaut, W.; Francois, F.; Salma, I.; Cafmeyer, J.; Gilot, C.

    1994-01-01

    The ''Gent'' staked filter unit sampler and other collection devices are used in regional and global scale studies on the tropospheric atmospheric aerosols, its composition, sources and fate. The aerosol samples are analyzed by particle-induced X-ray emission analysis, instrumental neutron activation analysis, ion chromatography, a light reflectance technique (for determining black carbon), and gravimetry (for measuring the particular mass). In evaluating the data, use is made of receptor modelling techniques, transport models and wind sector analysis, and also of air mass trajectories and other meteorological information. Preliminary results from a long-term study in southern Norway are presented. It is suggested that the anthropogenic and soil dust aerosol components are mainly adverted to southern Norway by long-range transport and that the major fraction of the submicrometer particle mass is from anthropogenic origin. Preliminary results are also presented for an intensive study in southern Africa. On the basis of the data for two sites (about 40 km apart) in the Kruger National Park it was concluded that regionally representative aerosol samples were collected and that the biomass burning products account for more than 50% of the fine particle mass. Finally, our plans for future work are given. (author). 70 refs, 4 figs, 1 tab

  6. Determination of heavy metals and other elements in sediments from Sepetiba Bay (RJ, Brazil) by neutron activation analysis; Determinacao de metais pesados e outros elementos em sedimentos da Baia de Sepetiba (RJ) por ativacao neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Pellegatti, Fabio

    2000-07-01

    Sepetiba Bay, located about 60 km south of the city of Rio de Janeiro, Brazil, is one of the most important fishery areas in the State of Rio de Janeiro. A large harbor brought up a lot of industrial investment in that area. Since the 1970's, the Sepetiba region has undergone fast industrial expansion, leading to high levels of pollution by metals. For the last two decades, an industrial park composed of about 400 industrial plants, basically metallurgical, was established in the Sepetiba Bay basin, releasing its industrial waste either straight into the bay or through local rivers. Metal contamination in the bay for some metals, such as Zn, has already exceeded acceptable levels. Many authors have studied the distribution and behavior of heavy metals and another elements in the bay, but only few elements have been focused (Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn). This is probably due to the fact that the analytical technique most employed has been atomic absorption spectrometry, which is not a multi-elemental technique. In this work, Instrumental Neutron Activation Analysis (INAA) was applied to the determination of the elements As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Lu, Nd, Rb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn in 28 bottom sediment samples and four sediment cores from Sepetiba Bay. The elements Co, Cr, Cs, Fe, Sc, Ta and Zn presented similar behavior in the bottom sediments, showing higher concentration along the Northern coast of the bay, where most of the fluvial water flows out to the bay. The contamination of Sepetiba Bay was also assessed by the analysis of four sediment cores. Two of them were sampled in the Eastern part of the bay, where the industrial park is located, whereas the other two were sampled in the Western part of the bay, a more preserved region. For each region, two cores were sampled within the mangrove trees and the others at the edge of the tidal flat. The results showed that, the sediments displayed higher metal concentration within

  7. US--ITER activation analysis

    International Nuclear Information System (INIS)

    Attaya, H.; Gohar, Y.; Smith, D.

    1990-09-01

    Activation analysis has been made for the US ITER design. The radioactivity and the decay heat have been calculated, during operation and after shutdown for the two ITER phases, the Physics Phase and the Technology Phase. The Physics Phase operates about 24 full power days (FPDs) at fusion power level of 1100 MW and the Technology Phase has 860 MW fusion power and operates for about 1360 FPDs. The point-wise gamma sources have been calculated everywhere in the reactor at several times after shutdown of the two phases and are then used to calculate the biological dose everywhere in the reactor. Activation calculations have been made also for ITER divertor. The results are presented for different continuous operation times and for only one pulse. The effect of the pulsed operation on the radioactivity is analyzed. 6 refs., 12 figs., 1 tab

  8. Applications of neutron activation analysis in industry

    International Nuclear Information System (INIS)

    Zaini Hamzah.

    1985-01-01

    Neutron activation analysis technique is discussed in brief. This technique is used for quality control of raw materials, process materials and finished products, as well as activities in research and development for the improvement of the products and new products. The uses of this technique in several experienced industries are mentioned (author)

  9. Development of neutron activation analysis software

    International Nuclear Information System (INIS)

    Wang Liyu

    1987-10-01

    The software for quantitative neutron activation analysis was developed to run under the MS/DOS operating system. The programmes of the IBM/SPAN include: spectra file transfer from and to a Canberra Series 35 multichannel analyzer, spectrum evaluation routines, calibration subprogrammes, and quantitative analysis. The programmes for spectrum analysis include fitting routine for separation of multiple lines by reproducing the peak shape with a combination of Gaussian and exponential terms. The programmes were tested on an IBM/AT-compatible computer. The programmes and the sources are available costfree for the IAEA projects of Technical Cooperation. 7 refs, 3 figs

  10. Proceedings of the specialist research meeting on 'the latest study on analysis of trace amount of elements using activation analysis and the results and future prospects of activation analysis using KUR'

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru; Shibata, Seiichi; Sekimoto, Shun

    2014-01-01

    This Specialist Research Meeting report is the summary of the lectures that were delivered at the Specialist Research Meeting of Kyoto University Reactor Research Institute on January 25, 2013 and October 30, 2013. These meetings were held under the subtitles of 'Current state of trace element analysis using activation analysis' and 'Achievements and future prospects of activation analysis using Kyoto University research reactor (KUR)', respectively. At the former meeting, 14 speeches were delivered including the following: (1) introduction of Australia Nuclear Science and Technology Organisation (ANSTO), (2) determination of element concentration in the hairs in frequent ALS (amyotrophic lateral sclerosis) occurrence zones, (3) effects of vegetation on the acid neutralizing capacity of soil, (4) activation analysis of geological samples, and (5) current situation of KUR. At the latter meeting, 15 speeches were delivered including the following: (1) neutron activation analysis of iron meteorites and Chinese herbal medicines / herbs, (2) neutron activation analysis at KUR using IAEA-k0 method, (3) current state of KUR, (4) development and applications of automatic prompt gamma-ray analysis equipment. (A.O.)

  11. Multielemental segregation analysis of the thallium bromide impurities purified by repeated Bridgman technique

    International Nuclear Information System (INIS)

    Santos, Robinson A. dos; Hamada, Margarida M.; Costa, Fabio E. da; Gennari, Roseli F.; Martins, Joao F.T.; Marcondes, Renata M.; Mesquita, Carlos H. de

    2011-01-01

    TlBr crystals were purified and grown by the repeated Bridgman method from two commercial TlBr salts and characterized to be used as radiation detectors. To evaluate the purification efficiency, measurements of the impurity concentration were made after each growth, analyzing the trace impurities by inductively coupled plasma mass spectroscopy (ICP-MS). A significant decrease of the impurity concentration resulting from the purification number was observed. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out. The radiation response depended on the crystal purity. The repeated Bridgman technique improved the TlBr crystal quality used as a radiation detector. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growth. (author)

  12. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  13. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  14. International conference activation analysis and its applications (ICAAA): abstracts

    International Nuclear Information System (INIS)

    1990-01-01

    International conference on the Activation Analysis and its Applications was hold in Beijing of China on October 15-19, 1990. It was organized and co-sponsored by Division of Activation Analysis and Radioanalysis, National Natural Science Foundation of China and China Nuclear Society, etc.. 159 pieces of Articles in the field were received in the conference, from many countries

  15. Instrumental activation analysis of molybdenites

    International Nuclear Information System (INIS)

    Geisler, M.; Schelhorn, H.

    1981-01-01

    Na, K, Sc, Cr, Fe, Co, Se, Rb, Ag, Cs, Ba, La, Ce, Eu, Yb, Hf, W, Re, and Th have been determined in 6 molybdenite samples by instrumental activation analysis. The samples were of different origin and showed K, Sc, W, and Re values with differences of more than two orders of magnitude, whereas Sc values were within one order of magnitude

  16. TXRF, PIXE and EDXRF: a first step towards normalization of x-ray spectrometry for chemical analysis

    International Nuclear Information System (INIS)

    Barreiros, M.A.; Costa, M.M.; Palha, M.; Pinheiro, T.; Araujo, M.F.; Silva, R.C. da

    2000-01-01

    Nowadays, many research studies rely on analytical measurements to which x-ray spectrometry techniques are particularly adequate. Because they are multi-elemental, versatile, fast and can reach low detection limits they are often applied to environmental and biomedical studies. Besides, they are able to provide reliable and accurate results. As also occurs with other analytical procedures, the quality assurance for non-routine analysis in R and D laboratories, is much less well established. when compared with routine analytical work. Thus, it is of foremost importance, to set the major quality parameters that significantly affect the quality of results. In addition, there is a need to apply the new concepts of trace ability and uncertainty to these techniques. This work reports on the reliability of TXRF, PIXE and EDXRF measurements by evaluating the uncertainty and trace ability for elemental analysis. The set of experimental and statistical procedures used to ensure the quality of results relative to the proposed objectives, as well as the methods applied to estimate the uncertainties will be presented and discussed. The sample preparation procedures, analytical calibration and spectral evaluation will be the parameters examined in this inter-laboratory study. The sample preparation procedures comprise pressure acid digestion and pelletizing for solid samples. The internal quality control for analytical calibration and spectral analysis is performed using certified reference materials and standard solutions. The goal of this work is to present a first step towards normalization of x-ray spectrometry techniques for chemical analysis. (author)

  17. The verification of neutron activation analysis support system (cooperative research)

    Energy Technology Data Exchange (ETDEWEB)

    Sasajima, Fumio; Ichimura, Shigeju; Ohtomo, Akitoshi; Takayanagi, Masaji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sawahata, Hiroyuki; Ito, Yasuo [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology; Onizawa, Kouji [Radiation Application Development Association, Tokai, Ibaraki (Japan)

    2000-12-01

    Neutron activation analysis support system is the system in which even the user who has not much experience in the neutron activation analysis can conveniently and accurately carry out the multi-element analysis of the sample. In this verification test, subjects such functions, usability, precision and accuracy of the analysis and etc. of the neutron activation analysis support system were confirmed. As a method of the verification test, it was carried out using irradiation device, measuring device, automatic sample changer and analyzer equipped in the JRR-3M PN-3 facility, and analysis software KAYZERO/SOLCOI based on the k{sub 0} method. With these equipments, calibration of the germanium detector, measurement of the parameter of the irradiation field and analysis of three kinds of environmental standard sample were carried out. The k{sub 0} method adopted in this system is primarily utilized in Europe recently, and it is the analysis method, which can conveniently and accurately carried out the multi-element analysis of the sample without requiring individual comparison standard sample. By this system, total 28 elements were determined quantitatively, and 16 elements with the value guaranteed as analytical data of the NIST (National Institute of Standards and Technology) environment standard sample were analyzed in the accuracy within 15%. This report describes content and verification result of neutron activation support system. (author)

  18. Activation analysis for the IFF system in RAON facility

    International Nuclear Information System (INIS)

    LEE, Cheol Woo; LEE, Young-Ouk; KIM, Jong Won; KIM, Mijung

    2014-01-01

    A heavy-ion accelerator facility is under a development in Korea to use in the basic science research and various application areas. In this facility, the In-Flight Fragment (IFF) target and isotope separator has been designed to produce various isotopes and transport the interesting isotopes into the experimental rooms. In this work, activation analysis for the pre-separator was performed in the IFF target room. In this work, activation analysis for the pre-separator was performed for the IFF target system in RAON heavy-ion accelerator facility. At first, radiation source terms were evaluated with the primary beams and target conditions. Using the evaluated source terms, induced activities in all component of pre-separator were calculated. The decay gamma-rays produced after a shutdown was estimated based on the activation analysis and gamma-ray dose rate according to the cooling time was evaluated

  19. A program for activation analysis data processing

    International Nuclear Information System (INIS)

    Janczyszyn, J.; Loska, L.; Taczanowski, S.

    1978-01-01

    An ALGOL program for activation analysis data handling is presented. The program may be used either for single channel spectrometry data or for multichannel spectrometry. The calculation of instrumental error and of analysis standard deviation is carried out. The outliers are tested, and the regression line diagram with the related observations are plotted by the program. (author)

  20. General principles of neutron activation analysis

    International Nuclear Information System (INIS)

    Dostal, J.; Elson, C.

    1980-01-01

    Aspects of the principles of atomic and nuclear structure and the processes of radioactivity, nuclear transformation, and the interaction of radiations with matter which are of direct relevance to neutron activation analysis and its application to geologic materials are discussed. (L.L.)

  1. Computer-automated neutron activation analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Garcia, S.R.

    1983-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. 5 references

  2. Activation analysis in the Americas: recent and future perspectives

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1984-01-01

    A total of 243 publications in the field of nuclear activation analysis and its applications during the period of 1977 through mid-1983, from laboratories in North, Central, and South America were reviewed. Various aspects of these populations are treated statistically, for indication of trends, and 146 of these are cited as publications that illustrate the extent of usage of various special forms of the nuclear activation analysis method (e.g., cyclic INAA, prompt-gamma INAA, epithermal NAA, the delayed-neutron method, the use of pre-irradiation chemical separations, etc.) - or that illustrate applications in such fields as archaeology, geochemistry, environmental chemistry, medicine, industry, and forensic chemistry. The overall conclusion is that the method of nuclear activation analysis continues to flourish in this region

  3. Neutron Activation Analysis with k0 standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    The objectives of the research are: (1) to develop and implement the k0 standardisation method for neutron activation analysis in close collaboration with scientific partners; (2) to exploit fully the inherent qualities of NAA such as accuracy, traceability, and multi-element offer complete services in health-physics measurements according to international quality standards, (2) to improve continuously these measurement techniques and to follow up international recommendations and legislation concerning the surveillance of workers; (3) to support and advise nuclear and non-nuclear industry on problems of radioactive contamination. Achievements in 1997 related to gamma spectrometry, whole-body counting, beta and alpha spectrometry, dosimetry, radon measurements, calibration, instrumentation, and neutron activation analysis are described

  4. Natural gold composition studied by proton activation analysis (PAA)

    International Nuclear Information System (INIS)

    Cojocaru, V.; Badica, T.; Popescu, I.V.

    2003-01-01

    The minor and trace element concentration of natural gold is essential for provenance studies of gold archaeological artifacts. In this work proton activation analysis is used in order to find what elements can be put into evidence in natural gold. For that purpose some gold nuggets from Romania were used. It was found that PAA is a good supplemental method to neutron activation analysis. (authors)

  5. Speciation analysis of cobalt in foods by high-performance liquid chromatography and neutron activation analysis

    International Nuclear Information System (INIS)

    Muto, Toshio; Koyama, Motoko

    1994-01-01

    A combined method by coupling high-performance liquid chromatography (HPLC, as a separation method) with neutron activation analysis (as a detection method) have been applied to the speciation analysis of cobalt in daily foods (e.g. egg, fish and milk). Cobalt species including free cobalt, vitamin B 12 and protein-bound cobalt were separated with a preparative HPLC and a centrifuge. Subsequently, the determination of cobalt in the separated species was made by neutron activation analysis. The results showed that the content of the total cobalt in the foods was found to lie in the range 0.4-11ng/g(0.4-11ppb) based on wet weight. The compositions of free cobalt, vitamin B 12 and protein-bound cobalt were ranged 16-43%, 55-73%, 2.3-17%, respectively. These experimental evidences suggest that the combination of HPLC and neutron activation analysis is expected to be a useful tool for speciation analysis of trace elements in biological as well as environmental materials. (author)

  6. Neutronic activation analysis of antique ceramics. Groups and differenciation

    International Nuclear Information System (INIS)

    Widemann, F.

    1975-01-01

    Different techniques for clay analysis in view of studying the origin of ceramics are exposed. The element abundance is measured by X-ray fluorescence analysis or by neutron activation analysis. Comparative tables of the results are established [fr

  7. Geochemical prospect ion results of Treinta y Tres aerial photo

    International Nuclear Information System (INIS)

    Zeegers, H.; Bonnefoy, D.; Garau, M.; Spangenberg, J.

    1981-01-01

    This report shows the geochemical prospect ion results carried out within the framework of the multielemental geochemical strategy. The samples were studied by e spectrometry in the laboratories of Orleans.

  8. Combination of the ionic-to-atomic line intensity ratios from two test elements for the diagnostic of plasma temperature and electron number density in Inductively Coupled Plasma Atomic Emission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tognoni, E. [Istituto per i Processi Chimico-Fisici, Area della Ricerca del Consiglio Nazionale delle Ricerche Via Moruzzi 1, 56124 Pisa (Italy)], E-mail: tognoni@ipcf.cnr.it; Hidalgo, M.; Canals, A. [Departamento de Quimica Analitica, Nutricion y Bromatologia. Universidad de Alicante. Apdo. 99, 03080, Alicante (Spain); Cristoforetti, G.; Legnaioli, S.; Salvetti, A.; Palleschi, V. [Istituto per i Processi Chimico-Fisici, Area della Ricerca del Consiglio Nazionale delle Ricerche Via Moruzzi 1, 56124 Pisa (Italy)

    2007-05-15

    In Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) spectrochemical analysis, the MgII(280.270 nm)/MgI(285.213 nm) ionic to atomic line intensity ratio is commonly used as a monitor of the robustness of operating conditions. This approach is based on the univocal relationship existing between intensity ratio and plasma temperature, for a pure argon atmospheric ICP in thermodynamic equilibrium. In a multi-elemental plasma in the lower temperature range, the measurement of the intensity ratio may not be sufficient to characterize temperature and electron density. In such a range, the correct relationship between intensity ratio and plasma temperature can be calculated only when the complete plasma composition is known. We propose the combination of the line intensity ratios of two test elements (double ratio) as an effective diagnostic tool for a multi-elemental low temperature LTE plasma of unknown composition. In particular, the variation of the double ratio allows us discriminating changes in the plasma temperature from changes in the electron density. Thus, the effects on plasma excitation and ionization possibly caused by introduction of different samples and matrices in non-robust conditions can be more accurately interpreted. The method is illustrated by the measurement of plasma temperature and electron density in a specific analytic case.

  9. Using Porterian Activity Analysis to Understand Organizational Capabilities

    DEFF Research Database (Denmark)

    Sheehan, Norman T.; Foss, Nicolai Juul

    2017-01-01

    conceptualized by Porter’s writings on the activity-based view. Porterian activity analysis is becoming more accepted in the strategy literature, but no strategy scholar has explicitly used Porter’s activities, and particularly his concept of drivers, to understand and analyze organizational capabilities....... Introducing Porterian activities into the discussion of capabilities improves strategy scholars’ understanding of the bases of capability heterogeneity, offers academics future directions for research, and provides managers with guidance to enhance their organizations’ capabilities....

  10. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  11. Phytochemical analysis and antioxidant activities of Combretum ...

    African Journals Online (AJOL)

    Phytochemical analysis and antioxidant activities of Combretum molle and Pericopsis laxiflora. Kossi-Kuma Agbalevon Koevi, Vinsoun Millogo, Jean Baptiste Hzounda Fokou, Abdou Sarr, Georges Anicet Ouedraogo, Emmanuel Bassene ...

  12. Use of gamma spectroscopy in activation analysis; Utilisation de la spectrographie gamma dans l'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Brief review of the principles of activation analysis: calculation of activities, decay curves, {beta} absorption curves, examples of application. - Principle and description of the {gamma} spectrograph. - Practical utilisation of the {gamma} spectrograph: analysis by activation, analysis by {beta} - x fluorescence. - Sensitivity limit of the method and precision of the measurements. - Possible improvements to the method: {gamma} spectroscopy with elimination of the Compton effect. (author) [French] Bref rappel des principes de l'analyse par activation: calcul des activites, courbes de decroissance, courbes d'absorption {beta}, exemples d'utilisation. - Principe et description du spectrographe {gamma}. - Utilisation pratique de la spectrographie {gamma}: analyse par activation, analyse par fluorescence {beta} - x. - Limite de sensibilite de la methode et precision des mesures. - Ameliorations possibles de la methode: spectrographe {gamma} avec elimination de l'effet Compton. (auteur)

  13. Betatron activation analysis of cupriferous flotation pulp

    International Nuclear Information System (INIS)

    Kaminski, R.; Matenko, J.; Mencel, J.; Janiczek, J.; Kielsznia, J.

    1974-01-01

    A method of copper determination in cupriferous flotation pulp by photo-activation analysis using betatron and another equipments of existent ''analytical line'' intended for copper determination in dry samples has been described. An activation has been achieved with 14.9 MeV γ-photons. The excitation activity was investigated by using two scintillation detectors and a fast coincidence circuit with resolution time 80 ns. The precision of method was determined as +- 4.25% in 0.95 confidence level for pulp with concentration 5% Cu and +- 24% for 0.06% Cu. (author)

  14. Recurrence analysis of ant activity patterns.

    Directory of Open Access Journals (Sweden)

    Felipe Marcel Neves

    Full Text Available In this study, we used recurrence quantification analysis (RQA and recurrence plots (RPs to compare the movement activity of individual workers of three ant species, as well as a gregarious beetle species. RQA and RPs quantify the number and duration of recurrences of a dynamical system, including a detailed quantification of signals that could be stochastic, deterministic, or both. First, we found substantial differences between the activity dynamics of beetles and ants, with the results suggesting that the beetles have quasi-periodic dynamics and the ants do not. Second, workers from different ant species varied with respect to their dynamics, presenting degrees of predictability as well as stochastic signals. Finally, differences were found among minor and major caste of the same (dimorphic ant species. Our results underscore the potential of RQA and RPs in the analysis of complex behavioral patterns, as well as in general inferences on animal behavior and other biological phenomena.

  15. Applications of neutrons for laboratory and industrial activation analysis problems

    International Nuclear Information System (INIS)

    Szabo, Elek; Bakos, Laszlo

    1986-01-01

    This chapter presents some particular applications and case studies of neutrons in activation analysis for research and industrial development purposes. The reactor neutrons have been applied in Hungarian laboratories for semiconductor research, for analysis of geological (lunar) samples, and for a special comparator measurement of samples. Some industrial applications of neutron generator and sealed sources for analytical problems are presented. Finally, prompt neutron activation analysis is outlined briefly. (R.P.)

  16. Quantitative Structure-Activity Relationship Analysis of the ...

    African Journals Online (AJOL)

    Erah

    Quantitative Structure-Activity Relationship Analysis of the Anticonvulsant ... Two types of molecular descriptors, including the 2D autocorrelation ..... It is based on the simulation of natural .... clustering anticonvulsant, antidepressant, and.

  17. Optimizing human activity patterns using global sensitivity analysis.

    Science.gov (United States)

    Fairchild, Geoffrey; Hickmann, Kyle S; Mniszewski, Susan M; Del Valle, Sara Y; Hyman, James M

    2014-12-01

    Implementing realistic activity patterns for a population is crucial for modeling, for example, disease spread, supply and demand, and disaster response. Using the dynamic activity simulation engine, DASim, we generate schedules for a population that capture regular (e.g., working, eating, and sleeping) and irregular activities (e.g., shopping or going to the doctor). We use the sample entropy (SampEn) statistic to quantify a schedule's regularity for a population. We show how to tune an activity's regularity by adjusting SampEn, thereby making it possible to realistically design activities when creating a schedule. The tuning process sets up a computationally intractable high-dimensional optimization problem. To reduce the computational demand, we use Bayesian Gaussian process regression to compute global sensitivity indices and identify the parameters that have the greatest effect on the variance of SampEn. We use the harmony search (HS) global optimization algorithm to locate global optima. Our results show that HS combined with global sensitivity analysis can efficiently tune the SampEn statistic with few search iterations. We demonstrate how global sensitivity analysis can guide statistical emulation and global optimization algorithms to efficiently tune activities and generate realistic activity patterns. Though our tuning methods are applied to dynamic activity schedule generation, they are general and represent a significant step in the direction of automated tuning and optimization of high-dimensional computer simulations.

  18. Diagnosis of mucoviscidosis by neutron activation analysis. Part 1

    International Nuclear Information System (INIS)

    Bellido, Luis F.; Bellido, Alfredo V.

    1997-02-01

    Symptoms pathology, incidence, and gravity of the inherent syndrome called mucoviscidosis, or cystic fibrosis are described in this Part I. The analytical methods used for its diagnosis, both the conventional chemical ones and by neutron activation analysis are also summarised. Finally, an analytical method to study the incidence of mucoviscidosis in Brazil is presented. This , essentially, consists in bromine determination, in fingernails, by resonance neutron activation analysis. (author)

  19. Neutron Activation analysis of waste water

    International Nuclear Information System (INIS)

    Hernandez H, V.

    1997-01-01

    An instrumental neutron activation analysis for the simultaneous determination of chlorine, bromine, sodium, manganese, cobalt, copper, chromium, zinc, nickel, antimony and iron in waste water is described. They were determined in waste water samples under normal conditions by non-destructive neutron activation simultaneously using a suitable monostandard method. Standardized water samples were used and irradiated in polyethylene ampoules at a neutron flux of 10 13 cm -2 s -1 for periods of 1 minute, 1 and 10 hours. A Ge hyperpure detector was used for your activity determination, with count times of 60, 180, 300 and 600 seconds. The obtained results show than the method can be utilized for the determination of this elements without realize anything previous treatment of the samples. (Author)

  20. Service activities of chemical analysis division

    International Nuclear Information System (INIS)

    Eom, Tae Yoon; Suh, Moo Yul; Park, Kyoung Kyun; Jung, Ki Suk; Joe, Kih Soo; Jee, Kwang Yong; Jung, Woo Sik; Sohn, Se Chul; Yeo, In Heong; Han, Sun Ho

    1988-12-01

    Progress of the Division during the year of 1988 was described on the service activities for various R and D projects carrying out in the Institute, for the fuel fabrication and conversion plant, and for the post-irradiation examination facility. Relevant analytical methodologies developed for the chemical analysis of an irradiated fuel, safeguards chemical analysis, and pool water monitoring were included such as chromatographic separation of lanthanides, polarographic determination of dissolved oxygen in water, and automation on potentiometric titration of uranium. Some of the laboratory manuals revised were also included in this progress report. (Author)

  1. Application of nuclear activation analysis

    International Nuclear Information System (INIS)

    Mamonov, E.I.; Khlystova, A.F.

    1979-01-01

    Consideration is given to the applications of nuclear-activation analysis (NAA) as discussed at the International Conference of 1977. One of the new results in the present-day NAA practices is the growing number of elements detected in samples without using a destructive radiochemical separation. An essential feature in this context is the development of the system automation of control and information NAA operations through the use computers. In biological medicine a multicomponent NAA is employed to determine the concentration of elements in various human organs and objects, in metabolic studies and for diagnostic purposes. In agriculture NAA finds applications in the evaluation of grain protein, analysis of element feed composition, soil and fertilizers. The application of this method to the environmental monitoring is considered with particular reference to the element analysis of water (especially drinking water), air, plant residues. Data are presented for the use of NAA in metallurgy, geology, archaeology and criminal law. Tables are provided to illustrate the uses of NAA in various fields

  2. Epithermal neutron activation analysis for studying the environment

    International Nuclear Information System (INIS)

    Frontas'eva, M.V.; Steinnes, E.

    1997-01-01

    Epithermal neutron activation analysis (ENAA) has certain advantages over the conventional instrumental analysis (INAA) in terms of improvement in precision and lowering of detection limits, reduction of high matrix activity and fission interferences if any. The current status and the applications of ENAA to environmental samples are reviewed. Experience in the use of ENAA in the monitoring of atmospheric depositions by means of moss-biomonitors at pulsed fast reactor IBR-2 in Dubna is summarized. INAA has shown to be useful for a number of sample types of interest in environmental studies, and should find more extensive use in this area. Analysis of airborne particulate matter is a case where ENAA should be particularly useful. A similar case where ENAA has shown strong performance is in the analysis of mosses used as biomonitors of atmospheric deposition, where 45 elements were determined. In this and other cases, however, induction-coupled plasma mass spectrometry is a very strong competitor, offering data for even more elements. A comparison of ENAA and ICP-MS for moss analysis is presented, and cases where ENAA is unique are discussed

  3. Mineralogical Approaches to Sourcing Pipes and Figurines from the Eastern Woodlands, U.S.A.

    Science.gov (United States)

    Wisseman, S.U.; Moore, D.M.; Hughes, R.E.; Hynes, M.R.; Emerson, T.E.

    2002-01-01

    Provenance studies of stone artifacts often rely heavily upon chemical techniques such as neutron activation analysis. However, stone specimens with very similar chemical composition can have different mineralogies (distinctive crystalline structures as well as variations within the same mineral) that are not revealed by multielemental techniques. Because mineralogical techniques are often cheap and usually nondestructive, beginning with mineralogy allows the researcher to gain valuable information and then to be selective about how many samples are submitted for expensive and somewhat destructive chemical analysis, thus conserving both valuable samples and funds. Our University of Illinois team of archaeologists and geologists employs Portable Infrared Mineral Analyzer (PIMA) spectroscopy, X-ray diffraction (XRD), and Sequential acid dissolution/XRD/Inductively coupled plasma (SAD-XRD-ICP) analyses. Two case studies of Hopewellian pipes and Mississippian figurines illustrate this mineralogical approach. The results for both studies identify sources relatively close to the sites where the artifacts were recovered: Sterling, Illinois (rather than Ohio) for the (Hopewell) pipes and Missouri (rather than Arkansas or Oklahoma) for the Cahokia figurines. ?? 2002 Wiley Periodicals, Inc.

  4. Biological monitors of air pollution

    International Nuclear Information System (INIS)

    Kucera, J.

    1994-01-01

    Direct biological monitoring of air pollution was introduced about 30 years ago. Although still under development, the application of biological monitors, or indicators, may provide important information on the levels, availability, and pathways of a variety of pollutants including heavy metals and other toxic trace elements in the air. A survey is given of the most frequently used biomonitors, such as herbaceous plants, tree leaves or needles, bryophytes, and lichens, with their possible advantages and/or limitations. In addition to using naturally-occurring biomonitors, a possibility of employing ''transplanted'' species in the study areas, for instance grasses grown in special containers in standard soils or lichens transplanted with their natural substrate to an exposition site, is also mentioned. Several sampling and washing procedures are reported. The important of employing nuclear analytical methods, especially instrumental neutron activation analysis, for multielemental analysis of biomonitors as a pre-requisite for unlocking the information contained in chemical composition of monitor's tissues, such as apportionment of emission sources using multivariate statistical procedures, is also outlined. (author). 32 refs, 2 figs

  5. Treatment of data in the study of elemental concentration of biological materials

    International Nuclear Information System (INIS)

    Ng, K. H.; Bradeley, D.A.; Looi, L.M.

    1994-01-01

    In the present work on the breast tissue, we detail the use of rigorous statistical methodology. We have carried out a multi-elemental analysis of 46 pairs of normal and malignant human breast tissue by instrumental neutron activation analysis. The TRIGA Mark II research reactor which was used provided a thermal neutron flux of the order of 10 sup 1 sup 2 neutrons cm sup -2 s sup -1. Twelve elements were determined. Sampling theory was used to determine the minimum number of paired samples required to yield a given discrimination power. Probability plots were applied to illustrate the log-normal and quasi-normal behaviour of distributions for all 12 of the elements which were examined. Statistically significant differences between malignant and normal tissue have been observed in respect of all elements using the Wilcoxon signed-ranks test. Finally, Spearman ranked correlation coefficients have been obtained, yielding a number of significant correlations between pairs of variables. We illustrate the value of such treatment by making comparisons with the results of a number of other studies of breast tissue. 2 figs., 2 refs. (Author)

  6. Determination of heavy metals in Damascus drinking water using total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Karajo, J.

    2000-01-01

    Total reflection x-ray fluorescence spectrometry and chemical preconcentration have applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 μg/l. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines. (author)

  7. Fast neutron activation analysis of Kalewa (Myanmar) coal

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Naing, W [Yangon Univ. (Myanmar). Dept. of Chemistry

    1994-06-01

    Aluminium, silicon, copper, iron, magnesium and sulfur in Kalewa (Myanmar) coal were determined by fast neutron activation analysis. For activation a KAMAN A-710 Neutron Generator was used. Kalewa coal was found to be low in sulfur and relatively rich in iron. (author) 2 refs.; 1 fig.; 1 tab.

  8. Fast neutron activation analysis of Kalewa (Myanmar) coal

    International Nuclear Information System (INIS)

    Myint, U.; Naing, W.

    1994-01-01

    Aluminium, silicon, copper, iron, magnesium and sulfur in Kalewa (Myanmar) coal were determined by fast neutron activation analysis. For activation a KAMAN A-710 Neutron Generator was used. Kalewa coal was found to be low in sulfur and relatively rich in iron. (author) 2 refs.; 1 fig.; 1 tab

  9. Molecular activation analysis for chemical speciation studies

    International Nuclear Information System (INIS)

    Chai-Chifang

    1998-01-01

    The term of Molecular Activation Analysis (MAA) refers to an activation analysis method that is able to provide information about the chemical species of elements in system of interests, though its definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the total concentrations are often without any meaning when assessing health or environmental risks of trace elements.In practice, the MAA is a combination of conventional instrumental or radiochemical activation analysis and physical, chemical or biochemical separation techniques. The MAA is able to play a particular role in speciation studies. However, the critical point in the MAA is that it is not permitted to change the primitive chemical species of elements in systems, or the change has to be under control; in the meantime it is not allowed to form the 'new artifact' originally not present in systems. Some practical examples of MAA for chemical species research performed recently in our laboratory will be presented as follows: Chemical species of platinum group elements in sediment; Chemical species of iodine in marine algae; Chemical species of mercury in human tissues; Chemical species of selenium in corn; Chemical species of rare earth elements in natural plant, etc. The merits and limitations of MAA will be described as well. (author)

  10. Activation Analysis and Public Health. Survey Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lenihan, I. M.A. [Western Regional Hospital Board, Glasgow (United Kingdom); Smith, H. [University of Glasgow, Glasgow (United Kingdom)

    1967-10-15

    The technique of activation analysis has useful and distinctive applications, not yet fully recognized or exploited, in public health. Three areas of usefulness may be recognized. 1. Industrial hygiene. Activation analysis offers a simple and efficient method for assessing and controlling occupational hazards associated with the handling of toxic materials, such as compounds of arsenic and of mercury. Examination of hair and nail samples, taken at six-monthly intervals, will yield a surprising amount of information regarding the influence on occupational exposure of individual variation in working habits, and inadequacy or non-observance of hygienic rules and other prescribed safety measures. 2. Epidemiology. The advantage conferred by activation analysis lies in the possibility of rapid and accurate estimation of trace element concentrations in small samples of tissue or other materials, such as can readily be obtained from population groups large enough to be statistically significant. Surveys of this kind have interesting potentialities in relation to dental caries, cancer, cirrhosis of the liver and heart disease. 3. Recognition of essential trace elements. Surveys of trace element concentrations suggest that the variability of tissue levels among members of a population is smaller for essential trace elements than for non-essential elements. It is possible also that tissue levels show a normal distribution for essential elements and a log-normal distribution for non-essential elements. (author)

  11. Neutron activation analysis: an emerging technique for conservation/preservation

    International Nuclear Information System (INIS)

    Sayre, E.V.

    1976-01-01

    The diverse applications of neutron activation in analysis, preservation, and documentation of art works and artifacts are described with illustrations for each application. The uses of this technique to solve problems of attribution and authentication, to reveal the inner structure and composition of art objects, and, in some instances to recreate details of the objects are described. A brief discussion of the theory and techniques of neutron activation analysis is also included

  12. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  13. Determination of uranium isotopes ({sup 235}U, {sup 238}U) and trace elements (Cd, Pb, Cu and As) in bottled drinking water by Icp-SFMS; Determinacion de isotopos de uranio ({sup 235}U, {sup 238}U) y elementos traza (Cd, Pb, Cu y As) en agua embotellada para beber por ICP-SFMS

    Energy Technology Data Exchange (ETDEWEB)

    Lara A, N.; Hernandez M, H.; Romero G, E. T.; Kuri de la C, A.; Perez B, M. A., E-mail: nancy.lara@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    In the present work we propose an optimized method for the quantification of uranium isotopes ({sup 235}U, 2{sup 38}U) and the elements Cd, Pb, Cu and As in bottled water for drinking at trace levels of concentration. Based on the multi-element detection capability, the high sensitivity and resolution that the Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma Source (Icp-SFMS) technique offers; the high, medium and low resolution analysis conditions for the elements under study were established and optimized using and Element 2/Xr equipment and the 23 multi-elemental Certified Reference Material (CRM). The analysis method was validated using the standard reference material Nist 1643d and CRM mono-elemental s as external standards for the quantification of the analytes. Samples, targets and CRM were acidified with 2% of HNO{sub 3} and analyzed without pretreatment under the established analysis conditions. The results obtained show concentrations of {sup 235}U, {sup 238}U, {sup 111}Cd, {sup 208}Pb, {sup 63}Cu and {sup 75}As in the range of μg L{sup -1}, the linearity obtained from the calibration curves for each element has correlation coefficients < 0.99 in all cases, the accuracy of the method in terms of percent relative standard deviation (RSD %) was less than 5%, the mean recovery rate of Nist 1643d ranged from 96.46% to 101.12%. The optimization of the method guarantees the stability and calibration of the equipment throughout the analysis, as well as the ability to resolve interferences. In conclusion, the method proposed using Icp-SFMS offers the advantages of being fast and simple for the multi-elemental analysis in water at trace levels, with low limits of quantification and detection, with good linearity, accuracy, precision and reproducibility to a degree of reliability of 95%. (Author)

  14. Determination of uranium isotopes (235U, 238U) and trace elements (Cd, Pb, Cu and As) in bottled drinking water by Icp-SFMS

    International Nuclear Information System (INIS)

    Lara A, N.; Hernandez M, H.; Romero G, E. T.; Kuri de la C, A.; Perez B, M. A.

    2016-09-01

    In the present work we propose an optimized method for the quantification of uranium isotopes ( 235 U, 2 38 U) and the elements Cd, Pb, Cu and As in bottled water for drinking at trace levels of concentration. Based on the multi-element detection capability, the high sensitivity and resolution that the Mass Spectrometry with Magnetic Sector with Inductively Coupled Plasma Source (Icp-SFMS) technique offers; the high, medium and low resolution analysis conditions for the elements under study were established and optimized using and Element 2/Xr equipment and the 23 multi-elemental Certified Reference Material (CRM). The analysis method was validated using the standard reference material Nist 1643d and CRM mono-elemental s as external standards for the quantification of the analytes. Samples, targets and CRM were acidified with 2% of HNO 3 and analyzed without pretreatment under the established analysis conditions. The results obtained show concentrations of 235 U, 238 U, 111 Cd, 208 Pb, 63 Cu and 75 As in the range of μg L -1 , the linearity obtained from the calibration curves for each element has correlation coefficients < 0.99 in all cases, the accuracy of the method in terms of percent relative standard deviation (RSD %) was less than 5%, the mean recovery rate of Nist 1643d ranged from 96.46% to 101.12%. The optimization of the method guarantees the stability and calibration of the equipment throughout the analysis, as well as the ability to resolve interferences. In conclusion, the method proposed using Icp-SFMS offers the advantages of being fast and simple for the multi-elemental analysis in water at trace levels, with low limits of quantification and detection, with good linearity, accuracy, precision and reproducibility to a degree of reliability of 95%. (Author)

  15. Limitations for qualitative and quantitative neutron activation analysis using reactor neutrons

    International Nuclear Information System (INIS)

    El-Abbady, W.H.; El-Tanahy, Z.H.; El-Hagg, A.A.; Hassan, A.M.

    1999-01-01

    In this work, the most important limitations for qualitative and quantitative analysis using reactor neutrons for activation are reviewed. Each limitation is discussed using different examples of activated samples. Photopeak estimation, nuclear reactions interference and neutron flux measurements are taken into consideration. Solutions for high accuracy evaluation in neutron activation analysis applications are given. (author)

  16. Systems Studies Department FY 78 activity report. Volume 2. Systems analysis

    International Nuclear Information System (INIS)

    Gold, T.S.

    1979-02-01

    The Systems Studies Department at Sandia Laboratories Livermore (SLL) has two primary responsibilities: to provide computational and mathematical services and to perform systems analysis studies. This document (Volume 2) describes the FY Systems Analysis highlights. The description is an unclassified overview of activities and is not complete or exhaustive. The objective of the systems analysis activities is to evaluate the relative value of alternative concepts and systems. SLL systems analysis activities reflect Sandia Laboratory programs and in 1978 consisted of study efforts in three areas: national security: evaluations of strategic, theater, and navy nuclear weapons issues; energy technology: particularly in support of Sandia's solar thermal programs; and nuclear fuel cycle physical security: a special project conducted for the Nuclear Regulatory Commission. Highlights of these activities are described in the following sections. 7 figures

  17. Nondestructive neutron activation analysis of silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Vandergraaf, T. T.; Wikjord, A. G.

    1973-10-15

    Instrumentel neutron activation analysis was used to determine trace constituents in silicon carbide. Four commercial powders of different origin, an NBS reference material, and a single crystal were characterized. A total of 36 activation species were identified nondestructively by high resolution gamma spectrometry; quantitative results are given for 12 of the more predominant elements. The limitations of the method for certain elements are discussed. Consideration is given to the depression of the neutron flux by impurities with large neutron absorption cross sections. Radiation fields from the various specimens were estimated assuming all radionuclides have reached their saturation activities. (auth)

  18. Conference on instrumental activation analysis IAA 85

    International Nuclear Information System (INIS)

    1985-05-01

    The conference heard 23 papers dealing with the application of activation analysis in environmental control, the preparation of calibration standards, gamma spectroscopy, data processing and with the control of the purity of radiopharmaceuticals. (J.P.)

  19. Meta-analysis of workplace physical activity interventions.

    Science.gov (United States)

    Conn, Vicki S; Hafdahl, Adam R; Cooper, Pamela S; Brown, Lori M; Lusk, Sally L

    2009-10-01

    Most adults do not achieve adequate physical activity levels. Despite the potential benefits of worksite health promotion, no previous comprehensive meta-analysis has summarized health and physical activity behavior outcomes from such programs. This comprehensive meta-analysis integrated the extant wide range of worksite physical activity intervention research. Extensive searching located published and unpublished intervention studies reported from 1969 through 2007. Results were coded from primary studies. Random-effects meta-analytic procedures, including moderator analyses, were completed in 2008. Effects on most variables were substantially heterogeneous because diverse studies were included. Standardized mean difference (d) effect sizes were synthesized across approximately 38,231 subjects. Significantly positive effects were observed for physical activity behavior (0.21); fitness (0.57); lipids (0.13); anthropometric measures (0.08); work attendance (0.19); and job stress (0.33). The significant effect size for diabetes risk (0.98) is less robust given small sample sizes. The mean effect size for fitness corresponds to a difference between treatment minus control subjects' means on VO2max of 3.5 mL/kg/min; for lipids, -0.2 on the ratio of total cholesterol to high-density lipoprotein; and for diabetes risk, -12.6 mg/dL on fasting glucose. These findings document that some workplace physical activity interventions can improve both health and important worksite outcomes. Effects were variable for most outcomes, reflecting the diversity of primary studies. Future primary research should compare interventions to confirm causal relationships and further explore heterogeneity.

  20. Development and simulation of various methods for neutron activation analysis

    International Nuclear Information System (INIS)

    Otgooloi, B.

    1993-01-01

    Simple methods for neutron activation analysis have been developed. The results on the studies of installation for determination of fluorine in fluorite ores directly on the lorry by fast neutron activation analysis have been shown. Nitrogen in organic materials was shown by N 14 and N 15 activation. The description of the new equipment 'FLUORITE' for fluorate factory have been shortly given. Pu and Be isotope in organic materials, including in wheat, was measured. 25 figs, 19 tabs. (Author, Translated by J.U)

  1. Current studies of biological materials using instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Fardy, J.J.; McOrist, G.D.; Farrar, Y.J.

    1985-01-01

    Instrumental neutron activation analysis still remains the preferred option when analysing the trace element distribution in a wide rage of materials by neutron activation analysis. However, when lower limits of detection are required or major interferences reduce the effectiveness of this technique, radiochemical neutron activation analysis is applied. This paper examines the current use of both methods and the development of rapid radiochemical techniques for analysis of the biological materials, hair, cow's milk, human's milk, milk powder, blood and blood serum

  2. Neutron activation analysis using TRIGA

    International Nuclear Information System (INIS)

    Byrne, A.R.

    1972-01-01

    Activation analysis with TRIGA MARK II is the main part of the work of the nuclear Chemistry Section at the Institute. A major part of the effort in this field is concerned with the determination of trace elements at the micro and nanogram level in a wide variety of materials, and with the development of new methods, (or the adaptation of known methods,) applicable to these determinations. In particular, specific and group radiochemical separations are studied

  3. Simulation for sodium-24 production using cyclic neutron activation analysis

    International Nuclear Information System (INIS)

    Ahamed, O. M. H.

    2012-04-01

    The cyclic neutron activation analysis is a method for elemental analysis which is preferred to use short-lived radio-nuclides. In recent years this method became a new application for radioisotope production especially in low power research reactors. In this study instrumental cyclic neutron activation analysis was used for 2 4N a production using 2 3N a (n, γ) 2 4N a reaction. The simplified westcott convention method is used neutron activation analysis in a research reactor. The method takes into account all corrections that can affect that yield created. In this work a model was devolving for calculations through this simplified Westcott convention method by using C++ program and selecting good parameters that can produce the expected activity. The simulation is used for the theoretical yield calculated has been validated by data from the 1 77L u production used for theoretical yield which it gives the approached result had been obtained by FORTRAN 90 from literature (8). The results were achieved for expected activity at full power (1 x 10 1 2n cm -2 s - 1 ) and half power (5 x 10 11 cm -2 s -1 ) for research reactor MNSR. The activity at full power was equal to about twice the activity at half power ( 49±7, 24.9 ± MBq/g), respectively. The irradiation parameters selected were irradiation time 4 min and decay time 12 min. Sample weight was 50 mg at 12 numbers of cycles, when the K-factor was equal to 1.74. This work is considered as first step for production of 2 4N a which can use such parameters experimentally. It is then possible to compare the expected activity with measured activity. (Author)

  4. Fast neutron activation analysis by means of low voltage neutron generator

    Directory of Open Access Journals (Sweden)

    M.E. Medhat

    Full Text Available A description of D-T neutron generator (NG is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given. Keywords: Neutron generator, Fast neutron activation analysis, Elemental analysis

  5. Multielement analysis of biological standards by neutron activation analysis

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1977-01-01

    Up to 28 elements were determined in two IAEA standards: Animal Muscle H4 and Fish Soluble A 6/74, and three NBS standards: Spinach: SRM-1570, Tomato Leaves: SRM-1573 and Pine Needles: SRM-1575 by instrumental neutron-activation analysis. Seven noble metals were determined in two NBS standards: Coal: SRM-1632 and Coal Fly Ash: SRM-1633 by radiochemical procedure while 11 rare earth elements were determined in NBS standard Orchard Leaves: SRM-1571 by instrumental neutron-activation analysis. The results are in good agreement with the certified and/or literature data where available. The irradiations were performed at the Cornell TRIGA Mark II nuclear reactor at a thermal neutron flux of 1-3x10 12 ncm -2 sec -1 . The short-lived species were determined after a 2-minute irradiation in the pneumatic rabbit tube, and the longer-lived species after an 8-hour irradiation in the central thimble facility. The standards and samples were counted on coaxial 56-cm 3 Ge(Li) detector. The system resolution was 1.96 keV (FWHM) with a peak to Compton ratio of 37:1 and counting efficiency of 13%, all compared to the 1.332 MeV photopeak of Co-60. (T.I.)

  6. Fast neutron activation analysis in metallurgy

    International Nuclear Information System (INIS)

    Sterlinski, S.

    1981-01-01

    Article discusses the usage of a 14 MeV neutron generator for producing fast neutrons of different energies and intensities. A complete instrumental set-up for the neutron activation analysis (NAA) is given. In metallurgy the device is mainly used in the determination of oxygen and silicon in steel and non-ferrous metal, including different alloys

  7. Laser-induced breakdown spectroscopy for in situ qualitative and quantitative analysis of mineral ores

    International Nuclear Information System (INIS)

    Pořízka, P.; Demidov, A.; Kaiser, J.; Keivanian, J.; Gornushkin, I.; Panne, U.; Riedel, J.

    2014-01-01

    In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis. - Highlights: • Twenty seven igneous rocks were measured on different LIBS systems. • Principal component analysis (PCA) was employed for classification. • The necessity of the classification of the rock (ore) samples prior to the quantification analysis is stressed. • Classification based on the whole LIP spectra and

  8. Laser-induced breakdown spectroscopy for in situ qualitative and quantitative analysis of mineral ores

    Energy Technology Data Exchange (ETDEWEB)

    Pořízka, P. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 61669 Brno (Czech Republic); Demidov, A. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Kaiser, J. [Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 61669 Brno (Czech Republic); Keivanian, J. [Institute for Mining, Technical University Clausthal, Erzstraße 18, 38678 Clausthal-Zellerfeld (Germany); Gornushkin, I. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Panne, U. [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany); Chemistry Department, Humboldt Univerisät zu Berlin, Brook-Taylor-Straße 2, D-12489 Berlin (Germany); Riedel, J., E-mail: jens.riedel@bam.de [BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany)

    2014-11-01

    In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis. - Highlights: • Twenty seven igneous rocks were measured on different LIBS systems. • Principal component analysis (PCA) was employed for classification. • The necessity of the classification of the rock (ore) samples prior to the quantification analysis is stressed. • Classification based on the whole LIP spectra and

  9. Neutron activation analysis applied to energy and environment

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1975-01-01

    Neutron activation analysis was applied to a number of problems concerned with energy production and the environment. Burning of fossil fuel, the search for new sources of uranium, possible presence of toxic elements in food and water, and the relationship of trace elements to cardiovascular disease are some of the problems in which neutron activation was used. (auth)

  10. Optimization of time characteristics in activation analysis

    International Nuclear Information System (INIS)

    Gurvich, L.G.; Umaraliev, A.T.

    2006-01-01

    Full text: The activation analysis temporal characteristics optimization methods developed at present are aimed at determination of optimal values of the three important parameters - irradiation time, cooling time and measurement time. In the performed works, especially in [1-5] the activation analysis processes are described, the optimal values of optimization parameters are obtained from equations solved, and the computational results are given for these parameters for a number of elements. However, the equations presented in [2] were inaccurate, did not allow one to have optimization parameters results for one element content calculations, and it did not take into account background dependence of time. Therefore, we proposed modified equations to determine the optimal temporal parameters and iteration processes for the solution of these equations. It is well-known that the activity of studied sample during measurements does not change significantly, i.e. measurement time is much shorter than the half-life, thus the processes taking place can be described by the Poisson probability distribution, and in general case one can apply binomial distribution. The equation and iteration processes use in this research describe both probability distributions. Expectedly, the cooling time iteration expressions obtained for one element analysis case are similar for the both distribution types, as the optimised time values occurred to be of the same order as half-life values, whereas the cooling time, as we observed, depends on the ratio of the studied sample's peak value to the background peak, and can be significantly larger than the half-life value. This pattern is general, and can be derived from the optimized time expressions, which is supported by the experimental data on short-living isotopes [3,4]. For the isotopes with large half-lives, up to years, like cobalt-60, the cooling time values given in the above mentioned works are equal to months which, apparently

  11. Activation analysis of some seaweeds of Myanmar

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Myint, Aye Myint [Yangon Univ. (Myanmar). Dept. of Chemistry

    1994-11-01

    Activation analysis of some seaweed samples occurring off the coastline areas of Myanmar is described. Na, K and I were determined using Am(Be) radionuclide neutron source and low level [beta]-counting. (author) 3 refs.; 1 fig.; 2 tabs.

  12. Use of activation analysis of hair in environmental protection

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1982-01-01

    Human hair is very suitable for use in environmental control monitoring because trace elements concentrate in it at higher levels than in most other organs. Unlike in other biological materials, the trace element contents in hair can be determined by instrumental neutron activation analysis (INAA), as the interference by 24 Na can be eliminated by appropriate washing of hair, e.g., using the procedure recommended by IAEA. The methods of sampling, washing and sample analysis using INAA and neutron activation analysis with radiochemical separation are described including the recommended way of the presentation of results. The results are presented of analyses for trace elements in hair from both little and highly polluted areas. (Ha)

  13. Pneumatic transport devices based on the ARS equipment set for activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.V.; Ivanets, V.N.; Rogachev, V.M.; Zakharov, E.A.

    1978-01-01

    The AGIDEL and ARS-28G facilities manufactured on the basis of a set of standardized and aggregated products for activation analysis are described. The AGIDEL is designed for automatic activation analysis of relatively homogeneous samples from oil boreholes. The ARS-28G is designed for transporting the test samples during activation analysis, using a fast-neutron generator. Structurally, the ARS-28 is based on a pneumatic transportation system with two independenhat transport cnnels and a two-channel rotating irradiation unit. The analyzed samples are transported in polyethylene containers, which are moved by compressed air. The facility has been successfully tested and is used in an automated system for multielement activation analysis

  14. Neutron activation analysis

    International Nuclear Information System (INIS)

    Okada, Yukiko

    2005-01-01

    Trends and progress in neutron activation analysis (NAA) for the period starting in 1999 to 2003 are presented. Numbers of published reports on NAA are decreasing year by year as investigated from the database JST and NUCLEN. Summary reports on the international conferences held on NAA are followed by classifying according to the fields: various measurement techniques and application fields. Specially focused topics are newly developed techniques for measuring trace elements with high sensitivity and high accuracy such as (1) by diminishing the Compton-background gamma-rays using anti-coincidence technique, (2) by using prompt-gamma rays measurement method (PGAA) and (3) by using a gamma-ray detector array (GEMINI), which has succeeded in a simultaneous quantification of 27 elements from a standard rock sample having a weight of only 10 milligrams, and others. These techniques will be applied in the space and earth sciences and medical fields. (S. Ohno)

  15. Radiochemical and instrumental neutron activation analysis - recent trends

    International Nuclear Information System (INIS)

    Dams, R.

    1990-01-01

    Recent trends of radiochemical and instrumental neutron activation analysis are discussed. Novel developments include the application of cyclic and pulsed activation, better energy resolution with hyperpure germanium detectors, and use of pulse processing systems allowing extremely high count rates of very short-lived isotopes. Further development is anticipated in the field of speciation in biological and environmental studies. Radiochemical methods have led to accurate determinations at the ng/g level. A promising future is expected for neutron activation techniques. (orig.)

  16. Non-invasive Field Measurements of Soil Water Content Using a Pulsed 14 MeV Neutron Generator

    Energy Technology Data Exchange (ETDEWEB)

    Mitra S.; Wielopolski L.; Omonode, R.; Novak, J.; Frederick, J.; Chan, A.

    2012-01-26

    Current techniques of soil water content measurement are invasive and labor-intensive. Here, we demonstrate that an in situ soil carbon (C) analyzer with a multi-elemental analysis capability, developed for studies of terrestrial C sequestration, can be used concurrently to non-invasively measure the water content of large-volume ({approx}0.3 m{sup 3}) soil samples. Our objectives were to investigate the correlations of the hydrogen (H) and oxygen (O) signals with water to the changes in the soil water content in laboratory experiments, and in an agricultural field. Implementing prompt gamma neutron activation analyses we showed that in the field, the signal from the H nucleus better indicates the soil water content than does that from the O nucleus. Using a field calibration, we were able to use the H signal to estimate a minimum detectable change of {approx}2% volumetric water in a 0-30 cm depth of soil.

  17. Cuban advances in the application of nuclear techniques in petroleum prospection

    International Nuclear Information System (INIS)

    Rodriguez Martinez, Norma; Montero Cabrera, Maria Elena

    1997-01-01

    Accumulated experience demonstrates how effective is the utilization of nuclear techniques in oil prospection. Until a little while ago the national geophysical service had a wide complex of nuclear and radioactive methods that were including: Methods Neutron compensated Gamma Density Cabotage Gamma and Natural Gamma for evaluating the properties of capacity and filtration of the hydrocarbons reservoirs. Neutronic Impulses Generating Method for determining and specifying the water-oil contact zone within the hydrocarbon deposits, radioactive tracers for: 1- detecting breakdowns in the coating pipeline of the wells, 2- for determining zones of losses of circulation of the fluid in the wells; Furthermore in laboratory conditions are used other nuclear analytical techniques: Neutron Activation Analysis, X-Ray Fluorescence, gamma spectrometry to determine multielemental composition of rocks including the traces elements. The determination, have permitted us to characterize each one of the sequences and they are used as a criterion for their stratigraphic differentiation at the same time, they are techniques-considering their affectation to neutronic methods

  18. Studies in heavy ion activation analysis Pt. 5

    International Nuclear Information System (INIS)

    Ojo, J.F.; Lass, B.D.; Schweikert, E.A.

    1980-01-01

    Nondestructive heavy ion activation analysis has been used to determine the carbon content in various NBS SRM steel samples with a 7.0 MeV 6 Li + beam. The reaction 12 C( 6 Li,αn) 13 N allows for carbon analysis with the only possible interference being beryllium, 9 Be( 6 Li,2n) 13 N. Under interference-free conditions, and employing a post-irradiation etch, the detection limit for carbon analysis in steel was 5 ppm. (author)

  19. Meta-Analysis of Workplace Physical Activity Interventions

    Science.gov (United States)

    Conn, Vicki S.; Hafdahl, Adam R.; Cooper, Pamela S.; Brown, Lori M.; Lusk, Sally L.

    2009-01-01

    Context Most adults do not achieve adequate physical activity. Despite the potential benefits of worksite health promotion, no previous comprehensive meta-analysis has summarized health and physical activity behavior outcomes from these programs. This comprehensive meta-analysis integrated the extant wide range of worksite physical activity intervention research. Evidence acquisition Extensive searching located published and unpublished intervention studies reported from 1969 through 2007. Results were coded from primary studies. Random-effects meta-analytic procedures, including moderator analyses, were completed in 2008. Evidence synthesis Effects on most variables were substantially heterogeneous because diverse studies were included. Standardized mean difference (d) effect sizes were synthesized across approximately 38,231 subjects. Significantly positive effects were observed for physical activity behavior (0.21), fitness (0.57), lipids (0.13), anthropometric measures (0.08), work attendance (0.19), and job stress (0.33). The significant effect size for diabetes risk (0.98) is more tentative given small sample sizes. Significant heterogeneity documents intervention effects varied across studies. The mean effect size for fitness corresponds to a difference between treatment minus control subjects' means on V02max of 3.5 mL/kg/min; for lipids, −0.2 on total cholesterol:HDL; and for diabetes risk, −12.6 mg/dL on fasting glucose. Conclusions These findings document that some workplace physical activity interventions can improve both health and important worksite outcomes. Effects were variable for most outcomes, reflecting the diversity of primary studies. Future primary research should compare interventions to confirm causal relationships and further explore heterogeneity. PMID:19765506

  20. Hilbert-Huang transform analysis of long-term solar magnetic activity

    Science.gov (United States)

    Deng, Linhua

    2018-04-01

    Astronomical time series analysis is one of the hottest and most important problems, and becomes the suitable way to deal with the underlying dynamical behavior of the considered nonlinear systems. The quasi-periodic analysis of solar magnetic activity has been carried out by various authors during the past fifty years. In this work, the novel Hilbert-Huang transform approach is applied to investigate the yearly numbers of polar faculae in the time interval from 1705 to 1999. The detected periodicities can be allocated to three components: the first one is the short-term variations with periods smaller than 11 years, the second one is the mid- term variations with classical periods from 11 years to 50 years, and the last one is the long-term variations with periods larger than 50 years. The analysis results improve our knowledge on the quasi-periodic variations of solar magnetic activity and could be provided valuable constraints for solar dynamo theory. Furthermore, our analysis results could be useful for understanding the long-term variations of solar magnetic activity, providing crucial information to describe and forecast solar magnetic activity indicators.

  1. A computer program for activation analysis

    International Nuclear Information System (INIS)

    Rantanen, J.; Rosenberg, R.J.

    1983-01-01

    A computer program for calculating the results of activation analysis is described. The program comprises two gamma spectrum analysis programs, STOAV and SAMPO and one program for calculating elemental concentrations, KVANT. STOAV is based on a simple summation of channels and SAMPO is based on fitting of mathematical functions. The programs are tested by analyzing the IAEA G-1 test spectra. In the determination of peak location SAMPO is somewhat better than STOAV and in the determination of peak area SAMPO is more than twice as accurate as STOAV. On the other hand, SAMPO is three times as expensive as STOAV with the use of a Cyber 170 computer. (author)

  2. Quality assurance in biomedical neutron activation analysis

    International Nuclear Information System (INIS)

    1984-01-01

    The summary report represents an attempt to identify some of the possible sources of error in in vitro neutron activation analysis of trace elements applied to specimens of biomedical origin and to advise on practical means to avoid them. The report is intended as guidance for all involved in analysis, including sample collection and preparation for analysis. All these recommendations constitute part of quality assurance which is here taken to encompass the two concepts - quality control and quality assessment. Quality control is the mechanism established to control errors, while quality assessment is the mechanism used to verify that the analytical procedure is operating within acceptable limits

  3. Applicability of the activation analysis with prompt neutron in medicine

    International Nuclear Information System (INIS)

    Yaghubian-Malhami, R.

    1975-04-01

    The concentrations of boron and cadmium in the human body are of great importance in medicine. The author determined their concentration by prompt neutron activation analysis in aqueous solutions and in urine. The results show that this technique may be used in medical diagnosis. The author discusses the qualities and the applicability of delayed and prompt neutron activation analysis in biology and medicine. (C.R.)

  4. Nondestructive neutron activation analysis of volcanic samples: Hawaii

    International Nuclear Information System (INIS)

    Zoller, W.H.; Finnegan, D.L.; Crowe, B.

    1986-01-01

    Samples of volcanic emissions have been collected between and during eruptions of both Kilauea and Mauna Loa volcanoes during the last three years. Airborne particles have been collected on Teflon filters and acidic gases on base-impregnated cellulose filters. Chemically neutral gas-phase species are collected on charcoal-coated cellulose filters. The primary analytical technique used is nondestructive neutron activation analysis, which has been used to determine the quantities of up to 35 elements on the different filters. The use of neutron activation analysis makes it possible to analyze for a wide range of elements in the different matrices used for the collection and to learn about the distribution between particles and gas phases for each of the elements

  5. Elemental analysis of bottom ash from municipal incinerator by neutron activation analysis

    International Nuclear Information System (INIS)

    Kim, S. H.; Jang, S. H.; Moon, J. H.; Jung, Y. S.; Kim, Y. J.

    2003-01-01

    Elemental analysis of bottom ash generated from municipal solid waste incinerator was performed by neutron activation analysis. For this study, ash samples monthly collected from incinerator in D city were sieved with 5 mm mesh size, dried, pulverized by agate mortar and finally re-sieved with 200μ mesh size. Prepared samples were irradiated by neutrons using NAA No.1 irradiation hole in Korea Atomic Energy Research Institute. Activated samples were measured by gamma-ray spectrometer according to the relevant nuclear properties of target nuclides and the concentration of 33 elements were determined from the collected ash samples. Quality control was conducted by comparative analysis with two NIST standard reference materials simultaneously. Mean values and standard deviations of hazardous elements such as As, Cr, Cu, Fe, Mn, Sb and Zn among the determined elements were 3.8±6.9mg/kg, 620±0.12 %, 4.76±0.37 %, 0.26±0.10 %, 115±29 mg/kg and 0.71±0.19 %, respectively

  6. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  7. Phosphorus analysis in milk samples by neutron activation analysis method

    International Nuclear Information System (INIS)

    Oliveira, R.M. de; Cunha, I.I.L.

    1991-01-01

    The determination of phosphorus in milk samples by instrumental thermal neutron activation analysis is described. The procedure involves a short irradiation in a nuclear reactor and measurement of the beta radiation emitted by phosphorus - 32 after a suitable decay period. The sources of error were studied and the established method was applied to standard reference materials of known phosphorus content. (author)

  8. Safeguards and Physics Measurements: Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2000-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  9. Preliminary study of elemental analysis of hydroxyapatite used neutron activation analysis method

    International Nuclear Information System (INIS)

    Yustinus Purwamargapratala; Rina Mulyaningsih

    2010-01-01

    Preliminary study has been carried out elemental analysis of hydroxyapatite synthesized using the method of neutron activation analysis. Hydroxyapatite is the main component constituent of bones and teeth which can be synthesized from limestone and phosphoric acid. Hydroxyapatite can be used as a bone substitute material and human and animal teeth. Tests on the metal content is necessary to prevent the risk of damage to bones and teeth due to contamination. Results of analysis using neutron activation analysis method with samples irradiated at the neutron flux 10"3 n.det"-"1cm"-"2 for one minute, the impurities of Al (48.60±6.47 mg/kg), CI (38.00±7.47 mg/kg), Mn (1.05±0.19 mg/kg), and Mg (2095.30±203.66 mg/kg), were detected, whereas with irradiation time for 10 minutes and 40 minutes with a time decay of three days there were K (103.89 ± 26.82 mg/kg), Br (1617.06 ± 193.66 mg/kg), and Na (125.10±9.57 mg/kg). These results indicate that there is impurity Al, CI, Mn, Mg, Br, K and Na, although in very small amounts and do not cause damage to bones and teeth. (author)

  10. Faculty Activity Analysis in the Universidad Tecnica Del Estado Campuses.

    Science.gov (United States)

    Karadima, Oscar

    An analysis of academic activities of college faculty at the eight campuses of Chile's Universidad Tecnica del Estado was conducted. Activities were grouped into seven categories: direct teaching, indirect teaching, research, community services, faculty development, academic administration, and other activities. Following the narrative…

  11. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  12. Target preparation and characterization for multielemental analysis of liquid samples by use of accelerators

    CERN Document Server

    Liendo, J A; Fletcher, N R; Gómez, J; Caussyn, D D; Myers, S H; Castelli, C; Sajo-Bohus, L

    1999-01-01

    Elastic scattering at forward angles is tested as a useful alternative method to characterize liquid samples of scientific and/or technological interest. Solid residues of such samples deposited on light backings have been bombarded with 16 MeV sup 7 Li and 24 MeV sup 1 sup 6 O beams in order to determine the experimental configuration giving the best elemental mass separation. The elastically scattered ions were detected at 16 deg. , 20 deg. and 28 deg. with surface barrier detectors. The ratios between the mass separation and the line width obtained in the spectral region between carbon and oxygen varied between 2 and 13. This method is particularly useful for an accurate elemental characterization below sodium which is beyond the scope of standard techniques such as PIXE and TXRF provided the ion beam type, its kinetic energy and the target thickness are considered simultaneously.

  13. Multielemental analysis of Korean geological reference samples by INAA, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Naoki Shirai; Hiroki Takahashi; Yuta Yokozuka; Mitsuru Ebihara; Meiramkhan Toktaganov; Shun Sekimoto

    2015-01-01

    Six Korean geological reference samples (KB-1, KGB-1, KT-1, KD-1, KG-1 and KG-2) prepared by Korea Institutes of Geoscience and Mineral Resources were analyzed by using INAA, ICP-AES and ICP-MS. Some elements could be determined by both INAA and non-INAA methods (ICP-AES and ICP-MS), and these data are consistent with each other. This study confirms that a combination of ICP-AES and ICP-MS is comparable to INAA in determining a wide range of major, minor and trace elements in geological materials. (author)

  14. Research activities in the fields of radiochemistry and neutron activation analysis using the LENA nuclear plant in Pavia

    International Nuclear Information System (INIS)

    Maggi, L.; Genova, N.; DiCasa, M.; Carmella-Crespi, V.

    1978-01-01

    In the past two years the activity of the Radiochemistry Laboratory and CNR Centre of Radiochemistry and Activation Analysis was mainly devoted to studies of nuclear activation analysis applied to different fields using the LENA reactor. Three NBS vegetable reference standards, Orchard Leaves, Tomato Leaves and Pine Needles, were analyzed for their halogen content. Halogen determination in foodstuff, vegetables and organic tissues gives valuable information on metabolic, nutritional, pollution and epidemiological fields. A detailed study on macro- and micro-elements content in Sardinian coal and its ashes was performed, in order to assess the possibility of using it as a fuel in electric power generating plants. Instrumental neutron activation analysis was used for the determination of Al, Si, Mn, Mg, Na, V, CI, Ce, Yb, Th, Cr, Hf, Cs, Se, Rb, Fe, Co, Ta, Eu, K, La and Sb. A multielement trace analysis of rock samples was developed in cooperation with scientists from other Universities; the determination of R.E., U, Th, Zr, Cs, Ba, Ni, Sc, Ta, Hf, Sr, and Cr by instrumental neutron activation analysis was carried out in connection with orogenetic studies of African Rocks. In the archaeological field ancient artefacts recently discovered during a digging campaign at Monza's Cathedral (Italy) were analyzed with the aim to trace their origin and compare their composition with similar samples whose dating is certain. As a contribute to the international program of certifying NBS reference standard materials, chromium in the Brewer's Yeast, recently proposed as a new SRM, was determined by both instrumental and destructive neutron activation analysis. In the study of the role and behaviour of trace elements in human physiology, vanadium was investigated in human blood, as a trace element of increasing interest in connection with its origin from pollutants. Nuclear activation analysis was also applied to marine organism samples under a contract for oceanographic research

  15. Applications of neutron activation analysis in chemistry and pollution fields

    International Nuclear Information System (INIS)

    May, S.

    1978-01-01

    Some examples of applications of activation analysis are given such as: chemical analysis of precious metals, nuclear graphite and hydrocarbons; control of pollution of water and seawater, analysis of food and seafood, atmospheric, dust and hair for determination of impurities [fr

  16. Development of HANARO Activation Analysis System and Utilization Technology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Cho, H. J. (and others)

    2007-06-15

    1. Establishment of evaluation system using a data for a neutron activation analysis : Improvement of NAA measurement system and its identification, Development of combined data evaluation code of NAA/PGAA, International technical cooperation project 2. Development of technique for a industrial application of high precision gamma nuclide spectroscopic analysis : Analytical quality control, Development of industrial application techniques and its identification 3. Industrial application research for a prompt gamma-ray activation analysis : Improvement of Compton suppression counting system (PGAA), Development of applied technology using a PGAA system 4. Establishment of NAA user supporting system and KOLAS management : Development and validation of KOLAS/ISO accreditation testing and identification method, Cooperation researches for a industrial application, Establishment of integrated user analytical supporting system, Accomplishment of sample irradiation facility.

  17. Development of HANARO Activation Analysis System and Utilization Technology

    International Nuclear Information System (INIS)

    Chung, Y. S.; Moon, J. H.; Cho, H. J.

    2007-06-01

    1. Establishment of evaluation system using a data for a neutron activation analysis : Improvement of NAA measurement system and its identification, Development of combined data evaluation code of NAA/PGAA, International technical cooperation project 2. Development of technique for a industrial application of high precision gamma nuclide spectroscopic analysis : Analytical quality control, Development of industrial application techniques and its identification 3. Industrial application research for a prompt gamma-ray activation analysis : Improvement of Compton suppression counting system (PGAA), Development of applied technology using a PGAA system 4. Establishment of NAA user supporting system and KOLAS management : Development and validation of KOLAS/ISO accreditation testing and identification method, Cooperation researches for a industrial application, Establishment of integrated user analytical supporting system, Accomplishment of sample irradiation facility

  18. 14 MeV proton activation analysis

    International Nuclear Information System (INIS)

    Constantinescu, B.; Ivanov, E.; Plostinaru, D.; Popa-Nemoiu, A.; Pascovichi, G.

    1985-01-01

    A fast nuclear nondestructive method for protein analysis using the 14 MeV proton activation has been developed. The total nitrogen content was measured through the reaction: 14 N (p,n) 14 O, (Tsub(1/2)=71 s). The 14 O activity was detected by means of its characteristic 2.312 MeV gamma-ray line with a NaI(Tl) detector. For a fast determination of a large number of samples a mechanized sistem reacting a rate of one sample per minute has been developed. The laboratory electronics comprises a multichannel analyser, a PDP computer and an electronic module comtroller. Comparison of the results obtained by the method described and the classical Kjeldal technique for samples of various cereal grains (soya bean seads, wheat, barley and corn) showed good correlation. A problem of the analysis of the whole protein region on corn and soya-bean seads, where this region is thicker (0,2 - 2 mm), is mentioned. In this case flour was proposed to be used to obtain a protein homogeneous sample and the irradiaton dose for a sample was about 33,000 Gy, mainly (99%) from protons (27 s x 100 nA x 14 MeV)

  19. Content Analysis in Systems Engineering Acquisition Activities

    Science.gov (United States)

    2016-04-30

    Acquisition Activities Karen Holness, Assistant Professor, NPS Update on the Department of the Navy Systems Engineering Career Competency Model Clifford...systems engineering toolkit . Having a common analysis tool that is easy to use would support the feedback of observed system performance trends from the

  20. Evaluation of analysis method standardless by WDXRF and EDXRF of aluminum powder used in MTR type fuel

    International Nuclear Information System (INIS)

    Scapin, Valdirene O.; Salvador, Vera L.R.; Cotrim, Marycel E.B.; Pires, Maria A.F.; Scapin, Marcos A.

    2011-01-01

    The nuclear fuel used in IEA-R1m reactor at the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP) is the MTR type. This fuel is compound of a core (U 3 Si 2 -Al dispersion briquette) wrapped in an aluminum plate with two cladding (superior and inferior) both in aluminum. The fuel element efficiency depends on the quality control of U 3 Si 2 and aluminum. For aluminum should be checked the impurities levels such as Si, Mn, Fe, Co, Cu, Zn and others and Al total . Aiming to provide a quick method, multielemental and non-destructive, the performance of the wavelength dispersive (WDXRF) and energy dispersive (EDXRF) X-ray fluorescence techniques, using the curve instrument sensitivity curve method, also known like standard less analysis, was evaluated. This method allows the determination from the element boron (Z=5) to uranium (Z=92) with concentrations ranging from 0.001 to 99.99% without the need for individual calibration curve and chemical pretreatments in the sample preparation. The results were compared with calibration curve method data, using statistical tests tools. By multivariate analysis of all the experimental data, especially by the discriminant analysis (DA) and cluster analysis (CA), respectively, it was possible to evaluate a correlation between variables of the applied analytical methods could be interpreted in context to qualify the fuels by XRF technique and method standard less. The results showed that the proposed method is satisfactory for both spectrometers; however it was found that the WDXRF presents the greatest conformity degree. (author)

  1. Neutron activation analysis for noble metals in matte leach residues

    International Nuclear Information System (INIS)

    Hart, R.J.

    1978-01-01

    The development of the neutron activation analysis technique as a method for rapid and precise determinations of platinum group metals in matte leach residues depends on obtaining a method for effecting complete and homogeneous sample dilution. A simple method for solid dilution of metal samples is outlined in this study, which provided a basis for the accurate determination of all the noble metals by the Neutron Activation Analysis technique

  2. Non-traditional neutron activation analysis by use of a nuclear reactor

    International Nuclear Information System (INIS)

    Mukhammedov, S.

    2003-01-01

    Full text: Traditional reactor neutron activation analysis (NAA) based on (n, γ) - thermal neutron capture nuclear reaction has been developed into a reliable and powerful analytical method, for trace element analysis, allowing the determination of over 60 chemical elements, with good accuracy and low detection limits. Considering all possibilities of activation and a radiochemical separation of the indicator radionuclide, the majority of the elements of this group can be determined at the ppm concentration level and below. However, for solving a number of analytical problems NAA technique is not well suited or it cannot be used at all. An important limitation is that all light elements, some medium and heavy elements cannot be determined even at ppm concentration level by this method, for example, H, Be, Li, B, C, N, O, Ti, Nb, Pb, etc. Accurate determination of lithium, oxygen and other light elements in sub-microgram level is of importance in geochemical and material studies. Such examples are great many. On such instances, several non-traditional reactor activation analysis can be used which have increasingly been developed and applied to several fields of semiconductor industry, biology, geology in recent years. The purpose of this presentation is to review the modern status of non-traditional nuclear reactor activation analysis based on use of nuclear reactions excited by the flow of secondary charged particles which are produced by two methods. In first method the triton flow is produced by thermal neutrons flux which excites the nuclear reaction 6 Li(n, α)T on lithium. The neutron activation analysis associated with two consecutive reactions 6 Li(n, α)T + 16 O(T, n) 18 F is established to determine trace amounts either of lithium or of oxygen in different geological, ecological and technological samples. Besides, the triton flow can be used for the determination of other light elements, for instance, B, N, S, Mg. This nuclear reactor triton activation

  3. Precision of neutron activation analysis for environmental biological materials

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroshi; Iwata, Shiro; Koyama, Mutsuo; Sasajima, Kazuhisa; Numata, Yuichi.

    1977-01-01

    Between 1973 and 1974 a special committee ''Research on the application of neutron activation analysis to the environmental samples'' had been organized at the Research Reactor Institute, Kyoto University. Eleven research groups composed mainly of the committee members cooperated in the intercomparison programme of the reactor neutron activation analysis of NBS standard reference material, 1571 Orchard Leaves and 1577 Bovine Liver. Five different type of reactors were used for the neutron irradiation; i.e. KUR reactor of the Research Reactor Institute, Kyoto University, TRIGA MARK II reactor of the Institute for Atomic Energy, Rikkyo University, and JRR-2, JRR-3, JRR-4 reactor of Japan Atomic Energy Research Institute. Analyses were performed mainly by instrumental method. Precision of the analysis of 23 elements in Orchard Leaves and 13 elements in Bovine Liver presented by the different research groups was shown in table 4 and 5, respectively. The coefficient of variation for these elements was from several to -- 30 percent. Averages given to these elements agreed well with the NBS certified or reference values. Thus, from the practical point of view for the routine multielement analysis of environmental samples, the validity of the instrumental neutron activation technique for this purpose has been proved. (auth.)

  4. Spatial heterogeneity analysis of brain activation in fMRI

    Directory of Open Access Journals (Sweden)

    Lalit Gupta

    2014-01-01

    Full Text Available In many brain diseases it can be qualitatively observed that spatial patterns in blood oxygenation level dependent (BOLD activation maps appear more (diffusively distributed than in healthy controls. However, measures that can quantitatively characterize this spatial distributiveness in individual subjects are lacking. In this study, we propose a number of spatial heterogeneity measures to characterize brain activation maps. The proposed methods focus on different aspects of heterogeneity, including the shape (compactness, complexity in the distribution of activated regions (fractal dimension and co-occurrence matrix, and gappiness between activated regions (lacunarity. To this end, functional MRI derived activation maps of a language and a motor task were obtained in language impaired children with (Rolandic epilepsy and compared to age-matched healthy controls. Group analysis of the activation maps revealed no significant differences between patients and controls for both tasks. However, for the language task the activation maps in patients appeared more heterogeneous than in controls. Lacunarity was the best measure to discriminate activation patterns of patients from controls (sensitivity 74%, specificity 70% and illustrates the increased irregularity of gaps between activated regions in patients. The combination of heterogeneity measures and a support vector machine approach yielded further increase in sensitivity and specificity to 78% and 80%, respectively. This illustrates that activation distributions in impaired brains can be complex and more heterogeneous than in normal brains and cannot be captured fully by a single quantity. In conclusion, heterogeneity analysis has potential to robustly characterize the increased distributiveness of brain activation in individual patients.

  5. Active Desiccant-Based Preconditioning Market Analysis and Product Development

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, J.

    2001-01-11

    The Phase 1 report (ORNL/Sub/94-SVO44/1), completed earlier in this program, involved a comprehensive field survey and market analysis comparing various specialized outdoor air handling units. This initial investigation included conventional cooling and reheat, conventional cooling with sensible recovery, total energy recovery systems (passive desiccant technology) and various active desiccant systems. The report concluded that several markets do promise a significant sales opportunity for a Climate Changer-based active desiccant system offering. (Climate Changer is a registered trademark of Trane Company.) This initial market analysis defined the wants and needs of the end customers (design engineers and building owners), which, along with subsequent information included in this report, have been used to guide the determination of the most promising active desiccant system configurations. This Phase 2 report begins with a summary of a more thorough investigation of those specific markets identified as most promising for active desiccant systems. Table 1 estimates the annual sales potential for a cost-effective product line of active desiccant systems, such as that built from Climate Changer modules. The Product Development Strategy section describes the active desiccant system configurations chosen to best fit the needs of the marketplace while minimizing system options. Key design objectives based on market research are listed in this report for these active desiccant systems. Corresponding performance goals for the dehumidification wheel required to meet the overall system design objectives are also defined. The Performance Modeling section describes the strategy used by SEMCO to design the dehumidification wheels integrated into the prototype systems currently being tested as part of the U.S. Department of Energy's Advanced Desiccant Technology Program. Actual performance data from wheel testing was used to revise the system performance and energy analysis

  6. Neutron activation analysis of atmospheric aerosols

    International Nuclear Information System (INIS)

    Riekstinya, D.V.; Mednis, I.V.; Veveris, O.Eh.

    1987-01-01

    A review of studies by Soviet and foreign authors on radioactivation analysis is presented. Instrumental neutron activation analysis (INAA) techniques have been developed providing the possibility to determine a number of elements in very small portions of aerosols for pollutanless areas of the Earth. Two ways of INAA are presented: with long- and short-living radionuclides. The Antarctic and the Indian Ocean aerosol samples have been analysed for 26 microelements. It has been stated that restrictions of the detection limits attained relate to high proportions of certain elements and their nonhomogeneous distribution in filters. The detection limits can be lowered by the filtered air volume growth per unit of the filter area

  7. Aspects of precision and accuracy in neutron activation analysis

    International Nuclear Information System (INIS)

    Heydorn, K.

    1980-03-01

    Analytical results without systematic errors and with accurately known random errors are normally distributed around their true values. Such results may be produced by means of neutron activation analysis both with and without radiochemical separation. When all sources of random variation are known a priori, their effect may be combined with the Poisson statistics characteristic of the counting process, and the standard deviation of a single analytical result may be estimated. The various steps of a complete neutron activation analytical procedure are therefore studied in detail with respect to determining their contribution to the overall variability of the final result. Verification of the estimated standard deviation is carried out by demonstrating the absence of significant unknown random errors through analysing, in replicate, samples covering the range of concentrations and matrices anticipated in actual use. Agreement between the estimated and the observed variability of replicate results is then tested by a simple statistic T based on the chi-square distribution. It is found that results from neutron activation analysis on biological samples can be brought into statistical control. In routine application of methods in statistical control the same statistical test may be used for quality control when some of the actual samples are analysed in duplicate. This analysis of precision serves to detect unknown or unexpected sources of variation of the analytical results, and both random and systematic errors have been discovered in practical trace element investigations in different areas of research. Particularly, at the ultratrace level of concentration where there are few or no standard reference materials for ascertaining the accuracy of results, the proposed quality control based on the analysis of precision combined with neutron activation analysis with radiochemical separation, with an a priori precision independent of the level of concentration, becomes a

  8. Applied research and development of neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Ryel; Kim, Young Gi; Jung, Hwan Sung; Park, Kwang Won; Kang, Sang Hun; Lim, Jong Myoung

    2003-05-01

    The aims of this project are to establish the quality control system of Neutron Activation Analysis(NAA) due to increase of industrial needs for standard analytical method and to prepare and identify the standard operation procedure of NAA through practical testing for different analytical items. R and D implementations of analytical quality system using neutron irradiation facility and gamma-ray measurement system and automation of NAA facility in HANARO research reactor are as following ; 1) Establishment of NAA quality control system for the maintenance of best measurement capability and the promotion of utilization of HANARO research reactor 2) Improvement of analytical sensitivity for industrial applied technologies and establishment of certified standard procedures 3) Standardization and development of Prompt Gamma-ray Activation Analysis (PGAA) technology

  9. On-stream analysis of coal by prompt neutron activation analysis

    International Nuclear Information System (INIS)

    Barker, D.

    1981-01-01

    The need for rapid continuous on-stream analysis of coal was recognised in 1975. Analytical systems capable of determining some of the most important compositional properties of coal have been developed. The research programme has produced a series of analysers suitable for on-stream, batch, slurry and laboratory analytical determination of coal. This series of analysers is marketed under the name of 'Nucoalyzer'. The Nucoalyzer - CONAC (Continuous On-line Nuclear Analyzer for Coal) offers real-time, continuous determination of calorific value, percentage ash, percentage moisture, percentage sulphur, boiler fouling and slagging indices. The CONAC model is described in this article. The analytical principle employed in the various Nucoalyzer systems is based on prompt neutron activation analysis

  10. Otolith edge fingerprints as approach for stock identification of Genidens barbus

    Science.gov (United States)

    Avigliano, Esteban; Maichak de Carvalho, Barbara; Leisen, Mathieu; Romero, Rurik; Velasco, Gonzalo; Vianna, Marcelo; Barra, Fernando; Volpedo, Alejandra Vanina

    2017-07-01

    The purpose of this paper is to assess the use of multi-elemental otolith fingerprints as a tool to delimit catfish Genidens barbus fish stocks in four estuaries from the southwestern Atlantic Ocean. Barium:Calcium (Ca), Magnesium:Ca, Manganese:Ca, Sodium:Ca and Strontium:Ca ratios in the otolith edge were determined by LA-ICPMS. PERMANOVA analysis reveal significant differences in the multi-element signatures among estuaries (p = 0.0001-0.002). Reclassification rates of quadratic discriminant analysis are high, averaging 89.9% (78-100%). The new data presented here show that the otolith chemistry is a potential tool for stock identification, and indicates the presence of at least four stocks which should probably be handled independently.

  11. Quantification of EFTEM elemental maps using ion beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, J.K.N. [Institut fuer Physik, Universitaet Augsburg, 86135 Augsburg (Germany)]. E-mail: lindner@physik.uni-augsburg.de; Haeberlen, M. [Institut fuer Physik, Universitaet Augsburg, 86135 Augsburg (Germany); Schwarz, F. [Institut fuer Physik, Universitaet Augsburg, 86135 Augsburg (Germany); AxynTeC Duennschichttechnik GmbH, Am Mittleren Moos 49, 86167 Augsburg (Germany); Thorwarth, G. [Institut fuer Physik, Universitaet Augsburg, 86135 Augsburg (Germany); AxynTeC Duennschichttechnik GmbH, Am Mittleren Moos 49, 86167 Augsburg (Germany); Stritzker, B. [Institut fuer Physik, Universitaet Augsburg, 86135 Augsburg (Germany); Hammerl, C. [AxynTeC Duennschichttechnik GmbH, Am Mittleren Moos 49, 86167 Augsburg (Germany); Assmann, W. [Sektion Physik der LMU Muenchen, Am Coulombwall 6, 85748 Garching (Germany)

    2006-08-15

    In this paper the nanometric spatial resolution capabilities of energy filtered cross-sectional transmission electron microscopy (EFTEM) element mapping are complemented with the ability of elastic recoil detection analysis (ERDA) and Rutherford backscattering spectroscopy (RBS) to perform absolute and standardless composition analysis of light and heavy elements. The strength of this combination of techniques is examplified by means of several {mu}m thick multielemental wear protection multilayer stacks of diamond-like carbon (DLC) and silicon compounds with individual sublayers of few ten nanometer thickness, which were analysed with respect to their composition. The result are quantitative high-resolution 2-dimensional distributions of different elements in the several {mu}m thick film sandwiches.

  12. Characterization of the Teotihuacan mural painting: application of the external particle beam as non destructive technique

    International Nuclear Information System (INIS)

    Martinez, C.; Manzanilla, L.; Ruvalcaba, J.L.; Ontalba, M.A.

    2005-01-01

    The characterization of technical indicators contained in the painting mural should follow a minim methodology from their discovery in the archaeological excavations until their analysis in the laboratory, with the purpose of rescuing diagnostic elements that mark the stages of socio cultural development in the towns. With this spirit it was carried out the present study analyzing some fragments of the Teotihuacan mural painting. The analysis consisted on applying some of the analytical techniques with particle beams used for archaeometry like the Proton induced X-ray emission (PIXE) and the particle elastic backscattering (RBS), due to it is treated of complementary techniques, very sensitive, of multielemental character, but mainly because its are non destructive analytical techniques. (Author)

  13. Activation analysis of deposited dust brought to Israel by dust storms

    International Nuclear Information System (INIS)

    Ganor, E.; Tal, A.; Donagi, A.

    1975-01-01

    The determination of dust particles deposited in Jerusalem during regional dust storms was carried out by polarized microscopy, X-ray analysis and atomic absorption measurements. These analyses showed the presence of particles of quartz, calcite, dolomite, feldspar, halite, kaolinite, montmorillonite, epidote, tourmaline, glauconite, illite and other heavy minerals. The aims of the present study were to apply activation analysis for the determination of element composition in dust samples; to compare the results obtained by activation analysis with those obtained by other methods, i.e. chemical analysis, polarized microscopy and X-ray analysis. The results obtained by the various methods were in good agreement. (B.G.)

  14. Application of X-ray spectroscopy in nondestructive photon activation analysis

    International Nuclear Information System (INIS)

    Weise, H.-P.; Segebade, Chr.

    1977-01-01

    The use of X-ray spectroscopy for the qualitative and quantitative analysis of samples activated by 30 MeV bremsstrahlung from an electron linear accelerator. Detection limits are calculated from the measured X-ray spectra and compared with those for γ-ray spectroscopy. In general, the detection limits for γ-ray and X-ray spectroscopy are comparable. Higher sensitivities for X-ray spectroscopy are observed when only low intensity γ-rays are emitted by the activation products. X-ray spectroscopy should be applied in three cases: (a) low γ-ray emission probability, (b) extremely complicated γ-ray spectrum, (c) overlapping of γ-ray lines from different elements. γ-ray spectroscopy should be preferred for the analysis of light elements for two reasons: very strong absorption of low energy X-rays (low Z) within the sample, low X-ray emission probability for the activation products of light elements. Therefore no attempt was made to use X-ray spectroscopy for the analysis of elements below Ti. Some practical applications of X-ray spectroscopy in nondestructive multielement analysis are quoted. (T.G.)

  15. Compositional Analysis and Antioxidant Activity of Volatile ...

    African Journals Online (AJOL)

    Compositional Analysis and Antioxidant Activity of Volatile. Components of Two Salvia spp. F Forouzin*, R Jamei and R Heidari. Department of Biology, Faculty of Science, Urmia University, West Azerbaijan, Iran. *For correspondence: Email: f_forouzin@yahoo.com, rjamei274@gmail.com, r.heidari@mail.urmia.ac.ir; Tel: ...

  16. Prehistory analysis using photon activation analysis

    International Nuclear Information System (INIS)

    Krausova, I.; Chvatil, D.; Tajer, J.

    2017-01-01

    Instrumental photon activation analysis (IPAA) is a suitable radio-analytical method for non-destructive determination of total nitrogen in various matrices. IPAA determination of nitrogen is based on 14 N (γ, n) 13 N nuclear reaction after high-energy photon irradiation. The analytically usable product of this photo-nuclear reaction is a positron emitter emitting only non-specific annihilation of 511 keV, which can be emitted by other radionuclides present in the sample. Some of them, besides the non-specific 511 keV line, also emit specific lines that allow their contribution to analytical radionuclide 13 N to be subtracted. An efficient source of high-energy photon radiation is the secondary bremsstrahlung generated by the conversion of the electron beam accelerated by a high-frequency circular accelerator - a microtron. The non-destructive IPAA contributed to the clarification of the origins of a precious bracelet originating from a fortified settlement in the area of Karlovy Vary - Drahovice from the late Bronze Age. (authors)

  17. Radiometric and Instrumental Neutron Activation Analysis (INAA) of environmental specimens: lacustrine sediments from Danube Delta

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    specificity analytical methods such as Instrumental Neutron Activation Analysis (INAA) could evidence more than 40 different elements at concentrations about ppm or lower. Unwanted events as atmospheric nuclear tests and Chernobyl accident discharged a great amount of radioactive 137 Cs that once fixed into sediments represents an excellent tracer for natural processes such as sediment transport, accumulation and redistribution during the last 40-50 years. For multielemental investigation of environmental samples such as soil, sediments, water or various minerals INAA is one of the most suitable technique. Presumably pollutants elements such as Cr, Co, Zn, As, Sb and Br as well as REE that could be easily determined by INAA are helpful indicators of the source as well as of the mechanism of deposition and incorporation of these components. Investigated in correlation with radiocesium distribution as well as some natural trace elements such as REE, Sc or Hf, their vertical profiles in sediments allows a rapid reconstruction of the history of recent pollution processes. Radiometric and INAA measurements have been performed 'in tandem' for sediments collected from different lakes located in both Fluvial (western part) and Fluvio-maritime (eastern part and the Razelm-Sinoe lacustrine complex) sections of the Danube Delta, i.e. Lung, Mesteru, Matita, Furtuna and Merhei as well as Razelm and Leahova, respectively. A review of these investigations concerning the vertical profiles of 4 major elements (Na, K, Ca and Fe), 15 trace elements (Rb, Cs, Ba, Sc, La, Ce, Sm, Eu, Tb, Yb, Lu, Th, U, Hf and Ta) as well as of 6 potential pollutants (Zn, Cr, Co, As, Sb and Br) in four lakes (Lung, Furtuna, Mester and Matita) together with anthropogenic 134 Cs and 137 Cs is presented. All these results reveal the great potential of radiometric as well as INAA in environmental as well as in geological investigations. (author)

  18. A twelve month study of PM2.5 and PM10 fine particle aerosol composition in the Sydney region using ion beam analysis techniques. Appendix 2

    International Nuclear Information System (INIS)

    Cohen, David D.; Bailey, G.M.; Kondepudi, Ramesh

    1995-01-01

    The accelerator based ion beam (IBA) analysis techniques of PIXE, PIGME, PESA, and RBS have been used to characterise fine particles at selected sites in the Sydney region. The four techniques operating simultaneously provide elemental concentrations on 24 chemical species, including H, Q N, 0, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Cu, Ni, Zn, Br and Pb. The total mass and the elemental carbon by laser integrated plate techniques were also measured. A stacked filter system, built by the University of Gent, Belgium and supplied by the IAEA was used to provide fine particle data on PM2.5 and PM10 particles. While a cyclone sampler, built at ANSTO, Lucas Heights, was used to provide data on PM2.5 particles only. The two different types of units were operated along side each other for the whole of 1994 and the results compared. The use of the multi-elemental IBA techniques also allowed for some fine particle source fingerprinting to be performed. (author)

  19. Effect of activation cross section uncertainties in transmutation analysis of realistic low-activation steels for IFMIF

    Energy Technology Data Exchange (ETDEWEB)

    Cabellos, O.; Garcya-Herranz, N.; Sanz, J. [Institute of Nuclear Fusion, UPM, Madrid (Spain); Cabellos, O.; Garcya-Herranz, N.; Fernandez, P.; Fernandez, B. [Dept. of Nuclear Engineering, UPM, Madrid (Spain); Sanz, J. [Dept. of Power Engineering, UNED, Madrid (Spain); Reyes, S. [Safety, Environment and Health Group, ITER Joint Work Site, Cadarache Center (France)

    2008-07-01

    We address uncertainty analysis to draw conclusions on the reliability of the activation calculation in the International Fusion Materials Irradiation Facility (IFMIF) under the potential impact of activation cross section uncertainties. The Monte Carlo methodology implemented in ACAB code gives the uncertainty estimates due to the synergetic/global effect of the complete set of cross section uncertainties. An element-by-element analysis has been demonstrated as a helpful tool to easily analyse the transmutation performance of irradiated materials.The uncertainty analysis results showed that for times over about 24 h the relative error in the contact dose rate can be as large as 23 per cent. We have calculated the effect of cross section uncertainties in the IFMIF activation of all different elements. For EUROFER, uncertainties in H and He elements are 7.3% and 5.6%, respectively. We have found significant uncertainties in the transmutation response for C, P and Nb.

  20. Application of neutron activation analysis to the determination of total mercury and other elements of interest in soil and sediment samples from Serra do Navio and Vila Nova River Basin, Amapa, Brazil; Aplicacao do metodo de ativacao neutronica a determinacao do mercurio total e outros elementos de interesse em amostras de solo e sedimento da Serra do Navio e Bacia do Rio Vila Nova, Amapa

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Cristina

    1997-07-01

    levels obtained in this work were compared to those from other Brazilian regions, where the gold mining activities are being carried out, releasing this metal to the environment. To the multielemental results, it was applied Varimax rotation factorial analysis to verify geochemistry signature of the soils and sediments from both studied regions, besides Pearson similarity correlation test application and comparison to average values of terrestrial crust. (author)

  1. Optimization of instrumental activation analysis conditions

    International Nuclear Information System (INIS)

    Guinn, V.; Gavrilas-Guinn, M.

    1993-01-01

    In instrumental neutron activation analysis (INAA) work, a good commonsense rule of thumb is that the opium conditions for the measurement of any induced activity, in a multi-element sample matrix, are an irradiation time, a decay time, and a counting time each approximately equal to the half-life of the radionuclide (if feasible). The INAA Advance Computer Program (APCP) was used to test this rule on ten reference materials. For the 280 radionuclide/material combinations traced through all 14 APCP condition sets, the rule predicted the best set for 67% of them, was off by one set for 31% of them, and was only off by two sets of 2% of them. (author) 6 refs.; 1 fig.; 3 tabs

  2. Development of prompt gamma activation analysis

    International Nuclear Information System (INIS)

    Olmez, I.

    1982-01-01

    Application of prompt gamma-activation analysis to some environmental samples and NBS's standard reference materials were examined, using NBS reactor and the technique developed by the nuclear chemistry group of the University of Maryland. Concentration of several elements, Cd, B, S, Se, Sb, Zn, Ba, Cr, Cs, Co, Si, Hf, Ce, Yb, Lu, Th, Sc, Eu, Fe, Ta and Rb, were determined by both PGAA and INAA. (author)

  3. Increasing physical activity with mobile devices: a meta-analysis.

    Science.gov (United States)

    Fanning, Jason; Mullen, Sean P; McAuley, Edward

    2012-11-21

    Regular physical activity has established physical and mental health benefits; however, merely one quarter of the U.S. adult population meets national physical activity recommendations. In an effort to engage individuals who do not meet these guidelines, researchers have utilized popular emerging technologies, including mobile devices (ie, personal digital assistants [PDAs], mobile phones). This study is the first to synthesize current research focused on the use of mobile devices for increasing physical activity. To conduct a meta-analysis of research utilizing mobile devices to influence physical activity behavior. The aims of this review were to: (1) examine the efficacy of mobile devices in the physical activity setting, (2) explore and discuss implementation of device features across studies, and (3) make recommendations for future intervention development. We searched electronic databases (PubMed, PsychINFO, SCOPUS) and identified publications through reference lists and requests to experts in the field of mobile health. Studies were included that provided original data and aimed to influence physical activity through dissemination or collection of intervention materials with a mobile device. Data were extracted to calculate effect sizes for individual studies, as were study descriptives. A random effects meta-analysis was conducted using the Comprehensive Meta-Analysis software suite. Study quality was assessed using the quality of execution portion of the Guide to Community Preventative Services data extraction form. Four studies were of "good" quality and seven of "fair" quality. In total, 1351 individuals participated in 11 unique studies from which 18 effects were extracted and synthesized, yielding an overall weight mean effect size of g = 0.54 (95% CI = 0.17 to 0.91, P = .01). Research utilizing mobile devices is gaining in popularity, and this study suggests that this platform is an effective means for influencing physical activity behavior. Our focus

  4. Trace analysis measurements in high-purity aluminium by means of radiochemical neutron and proton activation analysis

    International Nuclear Information System (INIS)

    Egger, K.P.

    1987-01-01

    The aim of the study consisted in the development of efficient radiochemical composite processes and activation methods for the multi-element determination of traces within the lower ng range in high-purity aluminium. More than 50 elements were determined with the help of activation with reactor neutrons; the selective separation of matrix activity (adsorption with hydrated antimony pentoxide) led to a noticeable improvement of detectability, as compared with instrumental neutron activation analysis. Further improvements were achieved with the help of radiochemical group separations in ion exchangers or with the help of the selective separation of the pure beta-emitting elements. Over 20 elements up to high atomic numbers were determined by means of activating 13 MeV protons and 23 Me protons. In this connection, improvements of the detection limit by as a factor of 10 were achieved with radiochemical separation techniques, as compared with pure instrumental proton activation analysis. (RB) [de

  5. An evaluation of inductively coupled plasma optical emission spectrometry using electrothermal atomisation sample introduction and photographic plate detection

    International Nuclear Information System (INIS)

    Khathing, D.T.; Pickford, C.J.

    1984-05-01

    A photographic radiation measurement approach has been used with an inductively coupled plasma source to evaluate and tabulate the more prominent optical emission lines of 66 elements. Compared with the more common sample introduction technique using nebulisation, increased sensitivity for multielement analysis of small samples was achieved by using a simple graphite electrothermal atomisation system. This was constructed to serve as a dual purpose atomiser ie both for Atomic Absorption and for Inductively Coupled Plasma Emission spectroscopy. The system offers the advantage of a wide multi-elemental coverage, but sensitivities achieved with photographic detection are poorer than those obtained photoelectrically. (author)

  6. Determination of the concentration profile of chemical elements in superheater pipes; Determinacion del perfil de concentracion de elementos quimicos en tubos de sobrecalentadores

    Energy Technology Data Exchange (ETDEWEB)

    Aldape U, F; Aspiazu F, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1986-05-15

    This work has for object to determine the profile of concentration of chemical elements at trace level in a superheater pipe of Thermoelectric Plants using the X-ray emission spectroscopy technique induced by protons coming from the Accelerator of the Nuclear Center. In the X-ray detection, a Si Li detector was used. The technique was chosen because it allows a multielemental analysis, of high sensitivity and precision. The results can help to understand the problems that are had in the change of flexibility or of corrosion. This will be from utility to the Federal Electricity Commission (CFE). (Author)

  7. Study of the elemental content in mollusk from Uruguayan's coast by X-ray fluorescence

    International Nuclear Information System (INIS)

    Bernasconi, G.; Odino, R.; Souto, B.; Mendez, Silvia

    1992-01-01

    The main objective of the study is to establish a starting point on the content of trace elements, either with a toxic and/or nutritional interest, in Uruguayan coastal mollusks. The River Plate is located between Argentina and Uruguay and has an estuarine nature. It is thus a zone with distinctive features among the South American Atlantic coasts. The analysis techniqe employed is X-ray fluroescence, which is non-destructive and multi-elemental. A simple way of sample preparation is proposed, which does not use reagents that may introduce foreign elements, and is therefore low cost. tabs

  8. Determination of the concentration profile of chemical elements in superheater pipes

    International Nuclear Information System (INIS)

    Aldape U, F.; Aspiazu F, J.

    1986-05-01

    This work has for object to determine the profile of concentration of chemical elements at trace level in a superheater pipe of Thermoelectric Plants using the X-ray emission spectroscopy technique induced by protons coming from the Accelerator of the Nuclear Center. In the X-ray detection, a Si Li detector was used. The technique was chosen because it allows a multielemental analysis, of high sensitivity and precision. The results can help to understand the problems that are had in the change of flexibility or of corrosion. This will be from utility to the Federal Electricity Commission (CFE). (Author)

  9. Elemental Study in Soybean and Products by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Vorapot, Permnamtip; Arporn Busamongkol; Sirinart, Laoharojanaphand

    2009-07-01

    Full text: Elements were analyzed in soybean and products by Instrumental Neutron Activation Analysis (INAA), Pseudo-Cyclic Instrumental Neutron Activation Analysis (PCINAA) and Epithermal Instrumental Neutron Activation Analysis (EINAA). Elements detected in sample were include Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn. The result showed that the nutritional contents changed after food processing. From experiments (n = 2), it was found that after food processing, the concentration of Cl and Na in soy bean curd increased from 0.0045 and 0.0011% to found 0.91 and 0.39 %, respectively. Other elements did not differ from soybean. Limits of detection for Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn were 0.05, 0.2, 50, 6, 10, 15, 0.05, 30, 40, 5, 5, 0.05 and 1 mg.kg - 1, respectively

  10. Major indicators of analysis of insurers’ investment activity

    Directory of Open Access Journals (Sweden)

    O.O. Poplavskyi

    2016-12-01

    Full Text Available The article is devoted to topical issues of economic nature, selection and use of economic indicators in analysis of insurers’ investment activity. The author determines the main criteria of permissible investment activity, such as different assets covering the insurance reserves and share of various types of investments in assets and capital on the base of the results of summarizing recent public requirements of key banks to insurance companies in Ukraine. The recommendations of the insurers’ analysis approved by the regulatory bodies in Ukraine (the State Commission for Regulation of Financial Services Markets, Belarus (the Ministry of Finance and Poland (the Financial Supervision Authority are not left without author’s attention. According to the results of comparing using of different indicators, like the return on equity and investment, their strength and weaknesses are identified and the improving the scales of their assessment are proposed. The article singles out the main indicators which can be adapted to national features+ and used for management decisions and regulation of investment activities of insurers.

  11. Content Analysis of a Computer-Based Faculty Activity Repository

    Science.gov (United States)

    Baker-Eveleth, Lori; Stone, Robert W.

    2013-01-01

    The research presents an analysis of faculty opinions regarding the introduction of a new computer-based faculty activity repository (FAR) in a university setting. The qualitative study employs content analysis to better understand the phenomenon underlying these faculty opinions and to augment the findings from a quantitative study. A web-based…

  12. Thermal analysis of physical and chemical changes occuring during regeneration of activated carbon

    Directory of Open Access Journals (Sweden)

    Radić Dejan B.

    2017-01-01

    Full Text Available High-temperature thermal process is a commercial way of regeneration of spent granular activated carbon. The paper presents results of thermal analysis conducted in order to examine high-temperature regeneration of spent activated carbon, produced from coconut shells, previously used in drinking water treatment. Results of performed thermogravimetric analysis, derivative thermogravimetric analysis, and differential thermal analysis, enabled a number of hypotheses to be made about different phases of activated carbon regeneration, values of characteristic parameters during particular process phases, as well as catalytic impact of inorganic materials on development of regeneration process. Samples of activated carbon were heated up to 1000°C in thermogravimetric analyser while maintaining adequate oxidizing or reducing conditions. Based on diagrams of thermal analysis for samples of spent activated carbon, temperature intervals of the first intense mass change phase (180-215°C, maximum of exothermic processes (400-450°C, beginning of the second intense mass change phase (635-700°C, and maximum endothermic processes (800-815°C were deter-mined. Analysing and comparing the diagrams of thermal analysis for new, previously regenerated and spent activated carbon, hypothesis about physical and chemical transformations of organic and inorganic adsorbate in spent activated carbon are given. Transformation of an organic adsorbate in the pores of activated carbon, results in loss of mass and an exothermic reaction with oxygen in the vapour phase. The reactions of inorganic adsorbate also result the loss of mass of activated carbon during its heating and endothermic reactions of their degradation at high temperatures.

  13. Neutron activation analysis of absolutely-dated tree rings

    International Nuclear Information System (INIS)

    Uenlue, K.; Hauck, D.K.; Kuniholm, P.I.; Chiment, J.J.

    2005-01-01

    Gold concentration was determined for dendrochronologically-dated wood samples using neutron activation analysis (NAA) and correlation sought with known environmental changes, e.g., volcanic activities, during historic periods. Uptake of gold is sensitive to soil pH for many plants. Data presented are from a single, cross-dated tree that grew in Greece. Using NAA, gold was measured with parts-per-billion sensitivity in individual tree rings from 1411 to 1988 AD. (author)

  14. Comparison of 3D quantitative structure-activity relationship methods: Analysis of the in vitro antimalarial activity of 154 artemisinin analogues by hypothetical active-site lattice and comparative molecular field analysis

    Science.gov (United States)

    Woolfrey, John R.; Avery, Mitchell A.; Doweyko, Arthur M.

    1998-03-01

    Two three-dimensional quantitative structure-activity relationship (3D-QSAR) methods, comparative molecular field analysis (CoMFA) and hypothetical active site lattice (HASL), were compared with respect to the analysis of a training set of 154 artemisinin analogues. Five models were created, including a complete HASL and two trimmed versions, as well as two CoMFA models (leave-one-out standard CoMFA and the guided-region selection protocol). Similar r2 and q2 values were obtained by each method, although some striking differences existed between CoMFA contour maps and the HASL output. Each of the four predictive models exhibited a similar ability to predict the activity of a test set of 23 artemisinin analogues, although some differences were noted as to which compounds were described well by either model.

  15. Utilization and facility of neutron activation analysis in HANARO research reactor

    International Nuclear Information System (INIS)

    Chung, Y.S.; Chung, Y.J.; Moon, J.H.

    1998-01-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10 13 -1.6x10 14 n/cm 2 ·s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  16. Multielement analysis of archaic Chinese bronze and antique coins by fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y.H. (Academia Sinica, Lanzhou, Gansu (China). Inst. of Modern Physics); Pepelnik, R.; Fanger, H.U. (GKSS-Forschungszentrum Geesthacht GmbH, Geesthacht-Tesperhude (Germany, F.R.). Inst. fuer Physik)

    1990-01-01

    Samples of archaic bronze have been investigated by fast neutron activation analysis using both the absolute and relative method. The components Cu, Zn, Sn and Pb have been determined quantitatively. For the detection of lead via the short-lived isomeric state {sup 207m}Pb, cyclic activation and measurement technique was used with pneumatic sample transfer between detector and central irradiation position of the neutron tube. For non-destructive analysis of antique Chinese coins the samples had to be irradiated outside the neutron generator KORONA. The activation reactions, the evaluation of the elemental concentrations and the accuracy of the results are discussed. The data were corrected for {gamma}-ray self-absorption in the samples and summing of coincident {gamma}-rays in the detector. According to reported typical compositions of Chinese bronze from different dynasties, the age of the samples has been derived from the results obtained. (orig.).

  17. Application of prompt gamma-ray activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Park, Kwang Won; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Ryel [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    This technical report is written for the promotion to utilization of prompt gamma-ray activation analysis facility to be installed in HANARO reactor. It is described for a practical aspects including experiment and equipments, methodology, current status of the research and development and its applications. 102 refs., 32 figs., 25 tabs. (Author)

  18. Isotopic neutron sources for neutron activation analysis

    International Nuclear Information System (INIS)

    Hoste, J.

    1988-06-01

    This User's Manual is an attempt to provide for teaching and training purposes, a series of well thought out demonstrative experiments in neutron activation analysis based on the utilization of an isotopic neutron source. In some cases, these ideas can be applied to solve practical analytical problems. 19 refs, figs and tabs

  19. Elemental analysis of combustion products by neutron activation

    International Nuclear Information System (INIS)

    Heft, R.E.; Koszykowski, R.F.

    1980-01-01

    This paper gives a brief description of the neutron activation analysis method, which is being used to determine the elemental profile of combustion products from coal-fired power plants, oil shale retorting, and underground coal gasification

  20. On neutron activation analysis with γγ coincidence spectrometry

    International Nuclear Information System (INIS)

    Zeisler, Rolf; Danyal Turkoglu; Ibere Souza Ribeiro Junior; Shetty, M.G.

    2017-01-01

    A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system. (author)

  1. Determination of silver using cyclic epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Pun, T.H.; Landsberger, S.

    2012-01-01

    A fast pneumatic transfer facility was installed in Nuclear Engineering Teaching Laboratory (NETL) of the University of Texas at Austin for the purpose of cyclic thermal and epithermal neutron activation analysis. In this study efforts were focused on the evaluation of cyclic epithermal neutron activation analysis (CENAA). Various NIST and CANMET certified materials were analyzed by the system. Experiment results showed 110 Ag with its 25 s half-life as one of the isotopes favored by the system. Thus, the system was put into practical application in identifying silver in metallic ores. Comparison of sliver concentrations as determined by CENAA in CANMET certified reference materials gave very good results. (author)

  2. Modern trends in activation analysis. Vols. 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Henkelmann, R; Kim, J I; Lux, F; Staerk, H; Zeisler, R [eds.

    1976-01-01

    Two volumes contain 164 special papers presented at the international conference on activation analysis, including five plenary lectures which give a general survey of modern trends and possibilities of applications in fields where activation analysis is capable of solving problems which are hitherto unsolved. The emphasis during this meeting is put on applications, though other subjects (e.g. sampling, homogeneity of samples, instrumental development, computer evaluation of gamma spectra, comparisons with other analytical methods) are also dealt with. The proceedings contain lectures on applications in the fields of biology, biomedicine, archaeology, the arts, forensic sciences, environmental research, ecology, materials research, geo- and cosmo-sciences, and other individual applications.

  3. Affective mapping: An activation likelihood estimation (ALE) meta-analysis.

    Science.gov (United States)

    Kirby, Lauren A J; Robinson, Jennifer L

    2017-11-01

    Functional neuroimaging has the spatial resolution to explain the neural basis of emotions. Activation likelihood estimation (ALE), as opposed to traditional qualitative meta-analysis, quantifies convergence of activation across studies within affective categories. Others have used ALE to investigate a broad range of emotions, but without the convenience of the BrainMap database. We used the BrainMap database and analysis resources to run separate meta-analyses on coordinates reported for anger, anxiety, disgust, fear, happiness, humor, and sadness. Resultant ALE maps were compared to determine areas of convergence between emotions, as well as to identify affect-specific networks. Five out of the seven emotions demonstrated consistent activation within the amygdala, whereas all emotions consistently activated the right inferior frontal gyrus, which has been implicated as an integration hub for affective and cognitive processes. These data provide the framework for models of affect-specific networks, as well as emotional processing hubs, which can be used for future studies of functional or effective connectivity. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Instrumental Neutron Activation Analysis for Human Hair

    International Nuclear Information System (INIS)

    Ratanatongchai, W.; Dharmvanij, W; Chongkum, S.

    1998-01-01

    Hair samples from students aged between 7 to 22 years old were analysed by neutron activation analysis at nuclear research reactor TRR-1.M1. From qualitative analysis of short-lived isotopes, A1, V, Ca, I, Cl, Mn, and Na were found. The quantity of those elements can be classified into three groups. The first group is A1, Ca, Na and Cl with variance less than 10%. The second group is V and I with variance between 10% to 50% and the third group, Mn, two samples have concentration about 12 times higher than the others

  5. Conference on instrumental activation analysis IAA 86

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1986-04-01

    Thirty five papers were presented at the conference held in Klucenice, Czechoslovakia from May 4 to 8, 1986. The abstracts of all papers are printed in the proceedings. The conference discussed the following problem areas: the application of activation analysis in determining elements in ores, tectites, fungi, the thyroid, the primary circuit coolant, semiconductor materials; the application of nuclear reaction analysis in determining elements in rubber and coal; the application of tracer techniques in metallurgy; the description of alpha and gamma spectrometric systems and their testing; the use of microcomputers for data processing, and the description of programs. (J.P.)

  6. Automatization of the neutron activation analysis method in the nuclear analysis laboratory

    International Nuclear Information System (INIS)

    Gonzalez, N.R.; Rivero, D del C.; Gonzalez, M.A.; Larramendi, F.

    1993-01-01

    In the present paper the work done to automatice the Neutron Activation Analysis technic with a neutron generator is described. An interface between an IBM compatible microcomputer and the equipment in use to make this kind of measurement was developed. including the specialized software for this system

  7. Critical reflection activation analysis - a new near-surface probe

    International Nuclear Information System (INIS)

    Gunn, J.M.F.; Trohidou, K.N.

    1988-09-01

    We propose a new surface analytic technique, Critical Reflection Activation Analysis (CRAA). This technique allows accurate depth profiling of impurities ≤ 100A beneath a surface. The depth profile of the impurity is simply related to the induced activity as a function of the angle of reflection. We argue that the technique is practical and estimate its accuracy. (author)

  8. Application of the neutron activation analysis to environmental study

    International Nuclear Information System (INIS)

    Fu Bozhi.

    1995-01-01

    Neutron activation analysis is a nuclear analysis technology. It has been developed in recent times. By this means, the paper analyzes the element contents of leaves, soil and atmospheric dust-fall from the eastern and the western suburbs of Chengdu, then makes a comparison between the two areas and approaches some problems on environmental pollution

  9. Neutron Activation Analysis with k0 Standardization

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation aims to: (1) develop and implement k 0 -standardisation method for NAA; (2) to exploit the inherent qualities of NAA such as accuracy, traceability, and multi-element capability; (3) to acquire technical spin-off for nuclear measurements services. Main achievements in 1997 are reported

  10. Use of research reactors for neutron activation analysis. Report of an advisory group meeting

    International Nuclear Information System (INIS)

    2001-04-01

    Neutron activation analysis (NAA) is an analytical technique based on the measurement of characteristic radiation from radionuclides formed directly or indirectly by neutron irradiation of the material of interest. In the last three decades, neutron activation analysis has been found to be extremely useful in the determination of trace and minor elements in many disciplines. These include environmental analysis applications, nutritional and health related studies, geological as well as material sciences. The most suitable source of neutrons for NAA is a research reactor. There are several application fields in which NAA has a superior position compared to other analytical methods, and there are good prospects in developing countries for long term growth. Therefore, the IAEA is making concerted efforts to promote neutron activation analysis and at the same time to assist developing Member States in better utilization of their research reactors. The purpose of the meeting was to discuss the benefits and the role of NAA in applications and research areas that may contribute towards improving utilization of research reactors. The participants focused on five specific topics: (1) Current trends in NAA; (2) The role of NAA compared to other methods of chemical analysis; (3) How to increase the number of NAA users through interaction with industries, research institutes, universities and medical institutions; (4) How to reduce costs and to maintain quality and reliability; (5) NAA using low power research reactors. Neutron activation analysis in its various forms is still active and there are good prospects in developing countries for long-term growth. This can be achieved by a more effective use of existing irradiation and counting facilities, a better end-user focus, and perhaps marginal improvements in equipment and techniques. Therefore, it is recommended that the Member States provide financial and other assistance to enhance the effectiveness of their laboratories

  11. A description of the BNL active surface analysis facility

    International Nuclear Information System (INIS)

    Tyler, J.W.

    1989-11-01

    Berkeley Nuclear Laboratories has a responsibility for the assessment of radioactive specimens arising both from post irradiation examination of power reactor components and structures and experimental programmes concerned with fission and activation product transport. Existing analytical facilities have been extended with the commissioning of an active surface analysis instrument (XSAM 800pci, Kratos Analytical). Surface analysis involves the characterisation of the outer few atomic layers of a solid surface/interface whose chemical composition and electronic structure will probably be different from the bulk. The new instrument consists three interconnected chambers positioned in series; comprising of a high vacuum sample introduction chamber, an ultra-high vacuum sample treatment/fracture chamber and an ultra-high vacuum sample analysis chamber. The sample analysis chamber contains the electron, X-ray and ion-guns and the electron and ion detectors necessary for performing X-ray photoelectron spectroscopy, scanning Auger microscopy and secondary-ion mass spectroscopy. The chamber also contains a high stability manipulator to enable sub-micron imaging of specimens to be achieved and provide sample heating and cooling between - 180 and 600 0 C. (author)

  12. Large Sample Neutron Activation Analysis: A Challenge in Cultural Heritage Studies

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Tzika, F.

    2007-01-01

    Large sample neutron activation analysis compliments and significantly extends the analytical tools available for cultural heritage and authentication studies providing unique applications of non-destructive, multi-element analysis of materials that are too precious to damage for sampling purposes, representative sampling of heterogeneous materials or even analysis of whole objects. In this work, correction factors for neutron self-shielding, gamma-ray attenuation and volume distribution of the activity in large volume samples composed of iron and ceramic material were derived. Moreover, the effect of inhomogeneity on the accuracy of the technique was examined

  13. Thin film analysis by instrumental heavy ion activation analysis using distributed recoil ranges of isotopic products

    International Nuclear Information System (INIS)

    Chowdhury, D.P.; Guin, R.; Saha, S.K.; Sudersanan, M.

    2006-01-01

    Thin foils (0.1 to 10 μm), metallic or polymeric, are frequently used in nuclear physics and chemistry experiments using ion beams from an accelerator. Very often it is important to know the major, minor and trace element composition of the foil. Several nuclear analytical techniques, namely RBS, ERDA, etc. are available for the near surface analysis. We have applied heavy ion activation analysis (HIAA) to explore the bulk composition of thin films. One of the difficulties in this method of thin film analysis is that the product nuclides from nuclear reaction come out of the sample surface due to high recoil energy. In thick sample, the recoiled nuclides are absorbed in the sample itself. This effect has been used to employ heavy ion activation for the analysis of thin films

  14. Utilization and facility of neutron activation analysis in HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y S; Chung, Y J; Moon, J H [Korea Atomic Energy Research Institute, P.O.Box 105 Yusong, 305-600, Taejon (Korea, Republic of)

    1998-07-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10{sup 13}-1.6x10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  15. Using Importance-Performance Analysis to Guide Instructional Design of Experiential Learning Activities

    Science.gov (United States)

    Anderson, Sheri; Hsu, Yu-Chang; Kinney, Judy

    2016-01-01

    Designing experiential learning activities requires an instructor to think about what they want the students to learn. Using importance-performance analysis can assist with the instructional design of the activities. This exploratory study used importance-performance analysis in an online introduction to criminology course. There is limited…

  16. Oesophageal cancer in the Transkei: multi-elemental investigation of plant material and water

    International Nuclear Information System (INIS)

    Renan, M.J.; Drennan, B.D.; Keddy, R.J.; Sellschop, J.P.F.

    1978-01-01

    A programme which investigates possible environmental factors which may have an effect on the demographic distribution of oesophageal cancer in the Transkei has been initiated. This report deals with the collection, handling and trace elemental analysis of maize leaves, rice, tomato leaves, spinach, pine needles and orchard leaves

  17. Activation analysis using {gamma} photons; Analyse par activation aux photons {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    This report summarizes all the data required for using photonuclear reactions in the field of analysis. After a brief review of the elementary properties of nuclear reactions induced by photon irradiation, the main characteristics are given of high energy (E > 20 MeV) Bremsstrahlung sources. The principle of activation analysis based on the use of photons is given. Actual examples of the analytic possibilities are described in detail, in particular in the case of the determination of very small quantities (< 10{sup -6}) of C, N, O and F. The influence of interfering nuclear reactions is discussed. (author) [French] Ce rapport se propose de resumer l'ensemble des connaissances indispensables pour l'utilisation des reactions photonucleaires a des fins analytiques. Apres quelques rappels concernant les proprietes elementaires des reactions nucleaires induites par irradiation dans les photons, les principales caracteristiques des sources de rayonnement de freinage de haute energie (E > 20 MeV)| sont donnees. Le principe de l'analyse par activation aux photons est rappele. Des exemples concrets sur les possibilites analytiques sont developpes, particulierement en ce qui concerne la determination de quantites tres faibles (< 10{sup -6}) de C, N, O et F. L'influence des reactions nucleaires parasites est discutee. (auteur)

  18. Religious Activities and Suicide Prevention: A Gender Specific Analysis

    Directory of Open Access Journals (Sweden)

    Steven Stack

    2018-04-01

    Full Text Available The present analysis contributes to the existing literature on religion and suicide in three interrelated ways: (1 providing an analysis of suicide completions whereas most research is based on non-lethal levels of suicidality; (2 assessing the relationship with concrete individual level data on completed suicides instead of aggregated data marked by the ecological fallacy issue; and (3 providing gender specific analyses to determine if the relationship is gendered. METHODS. Data come from the U.S. Public Health Service, National Mortality Followback Survey. They refer to 16,795 deaths including 1385 suicides. Significant others of the deceased were interviewed to measure all variables. The dependent variable is a binary variable where 1 = death by suicide and 0 = all other causes. The central independent variable is an index of religious activities. Controls are included for five categories of confounders (1 psychiatric morbidity; (2 help-seeking behavior; (3 Opportunity factors such as firearms; (4 social integration; and (5 demographics. RESULTS. Multivariate logistic regression analysis determined that controlling for 16 predictors of suicide, a one unit increase in religious activities reduced the odds of a suicide death by 17% for males and by 15% for females. The difference in coefficients is not significant (Z = 0.51. Other significant predictors of suicide deaths included suicide ideation (OR = 8.87, males, OR = 11.48, females and firearm availability (OR = 4.21, males, OR = 2.83, females. DISCUSSION. Religious activities were found to lower suicide risk equally for both men and women. Further work is needed to assess pathways, including suicide ideation, between religious activities and lowered suicide risk. This is the first U.S. based study to test for a gendered association between religion and suicide at the individual level of analysis.

  19. Antiglycation and Antioxidant Activities and HPTLC Analysis of ...

    African Journals Online (AJOL)

    Furthermore, high performance thin layer chromatography (HPTLC) analysis of Boswellia sacra resins was also carried out. Results: Polar fractions of the extract obtained exhibited the highest antiglycation activity while nonpolar fractions showed more than 50 % inhibition in superoxide anion scavenging assay.

  20. Vanadium determination in pretoleum by neutron activation analysis

    International Nuclear Information System (INIS)

    Lopez, M.; Espinosa, R.

    1983-01-01

    The vanadium concentration in an Peruvian petroleum sample is determined by neutron activation analysis. The samples were irradiated for 20 minutes with a flux of thermal neutrons of 1.75 x 10 7 n/cm 2 -s in a subcritical assembly. The activity of the created samples decreases to half 15 minutes after the irradiation. The result is 28.3 +- 0.8 p.p.m. with a typical deviation of 2.8%. The detection limit of this method is 4 p.p.m

  1. Estimation of 129I by low energy spectrometry and neutron activation analysis

    International Nuclear Information System (INIS)

    Ravi, P.M.; Iyer, M.R.; Sahasrabudhe, S.G.; Somasundaram, S.; Subramanian, M.S.

    1986-01-01

    Methods have been developed for the estimation of 129 I by direct passive counting and by neutron activation analysis. The direct counting method using low energy photon spectrometry has been standardised for liquid samples. Interference from different induced radionuclides in the activation method was studied. Limits of detection of 129 I by direct counting method and neutron activation analysis work out to be 0.4 Bq and 1mBq respectively. (author). 6 refs

  2. Flow injection electrochemical hydride generation inductively coupled plasma time-of-flight mass spectrometry for the simultaneous determination of hydride forming elements and its application to the analysis of fresh water samples

    International Nuclear Information System (INIS)

    Bings, Nicolas H.; Stefanka, Zsolt; Mallada, Sergio Rodriguez

    2003-01-01

    A flow injection (FI) method was developed using electrochemical hydride generation (EcHG) as a sample introduction system, coupled to an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) for rapid and simultaneous determination of six elements forming hydrides (As, Bi, Ge, Hg, Sb and Se). A novel low volume electrolysis cell, especially suited for FI experiments was designed and the conditions for simultaneous electrochemical hydride generation (EcHG; electrolyte concentrations and flow rates, electrolysis voltage and current) as well as the ICP-TOFMS operational parameters (carrier gas flow rate, modulation pulse width (MPW)) for the simultaneous determination of 12 isotopes were optimized. The compromise operation parameters of the electrolysis were found to be 1.4 and 3 ml min -1 for the anolyte and catholyte flow rates, respectively, using 2 M sulphuric acid. An optimum electrolysis current of 0.7 A (16 V) and an argon carrier gas flow rate of 0.91 l min -1 were chosen. A modulation pulse width of 5 μs, which influences the sensitivity through the amount of ions being collected by the MS per single analytical cycle, provided optimum results for the detection of transient signals. The achieved detection limits were compared with those obtained by using FI in combination with conventional nebulization (FI-ICP-TOFMS); values for chemical hydride generation (FI-CHG-ICP-TOFMS) were taken from the literature. By using a 200 μl sample loop absolute detection limits (3σ) in the range of 10-160 pg for As, Bi, Ge, Hg, Sb and 1.1 ng for Se and a precision of 4-8% for seven replicate injections of 20-100 ng ml -1 multielemental sample solutions were achieved. The analysis of a standard reference material (SRM) 1643d (NIST, 'Trace Elements in Water') showed good agreement with the certified values for As and Sb. Se showed a drastic difference, which is probably due to the presence of hydride-inactive Se species in the sample. Recoveries better than

  3. Mediation analysis of the relationship between institutional research activity and patient survival

    DEFF Research Database (Denmark)

    Rochon, Justine; du Bois, Andreas; Lange, Theis

    2014-01-01

    BACKGROUND: Recent studies have suggested that patients treated in research-active institutions have better outcomes than patients treated in research-inactive institutions. However, little attention has been paid to explaining such effects, probably because techniques for mediation analysis...... existing so far have not been applicable to survival data. METHODS: We investigated the underlying mechanisms using a recently developed method for mediation analysis of survival data. Our analysis of the effect of research activity on patient survival was based on 352 patients who had been diagnosed...... mediated through either optimal surgery or chemotherapy. Taken together, about 26% of the beneficial effect of research activity was mediated through the proposed pathways. CONCLUSIONS: Mediation analysis allows proceeding from the question "Does it work?" to the question "How does it work?" In particular...

  4. Some Applications of Fast Neutron Activation Analysis of Oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Owrang, Farshid

    2003-07-01

    illustrated how the activated water would propagate along that pipe. C) Combustion products. In order to investigate the oxidation in combustion products (deposits), the total amount of oxygen in the deposits collected from combustion chambers of a modern gasoline engine was measured, using cyclic fast neutron activation analysis (FNAA). As a compartment, the organic compounds containing oxygen were identified using {sup 13}C solid-state nuclear magnetic resonance (NMR) spectroscopy. The results of FNAA showed that the amount of oxygen in deposits varies depending on where the deposits have been formed. {sup 13}C NMR has showed that the carbon backbone of the deposits exists as highly oxidized poly aromatics and/or graphitic structure. D) On-line fast neutron activation analysis. On-line neutron activation analysis was used to detect the amount of oxygen in bulk liquids. The method was optimised for on-line detection of oxygen in rapeseed oil. The goal was to develop a non-intrusive method for measurement of the total amount of oxygen in oil during combustion/oxidation.

  5. Some Applications of Fast Neutron Activation Analysis of Oxygen

    International Nuclear Information System (INIS)

    Owrang, Farshid

    2003-01-01

    illustrated how the activated water would propagate along that pipe. C) Combustion products. In order to investigate the oxidation in combustion products (deposits), the total amount of oxygen in the deposits collected from combustion chambers of a modern gasoline engine was measured, using cyclic fast neutron activation analysis (FNAA). As a compartment, the organic compounds containing oxygen were identified using 13 C solid-state nuclear magnetic resonance (NMR) spectroscopy. The results of FNAA showed that the amount of oxygen in deposits varies depending on where the deposits have been formed. 13 C NMR has showed that the carbon backbone of the deposits exists as highly oxidized poly aromatics and/or graphitic structure. D) On-line fast neutron activation analysis. On-line neutron activation analysis was used to detect the amount of oxygen in bulk liquids. The method was optimised for on-line detection of oxygen in rapeseed oil. The goal was to develop a non-intrusive method for measurement of the total amount of oxygen in oil during combustion/oxidation

  6. Physical Activity and Cognitive Development: A Meta-Analysis.

    Science.gov (United States)

    Jackson, William M; Davis, Nicholas; Sands, Stephen A; Whittington, Robert A; Sun, Lena S

    2016-10-01

    Is there an association between regular exercise, defined as a structured program of increased physical activity at least 1 month in duration, and improvements in measures of executive functions compared with children who engage in their normal daily activities? The association between increased physical activity and changes in performance on tasks of executive functions have not been well elucidated in children. Executive functioning is important to intellectual development and academic success in children, and inexpensive, nonpharmacological methods for the treatment of executive dysfunction represent an attractive interventional target. To estimate the effect of a structured regular exercise program on neuropsychological domains of executive function in children ages 7 to 12. We performed a systematic review of English and non-English articles using Cochrane Library, EBSCO CINAHL, Ovid MEDLINE, PSYCInfo, Pubmed, and Web of Science, including all years allowed by each individual search engine. The search string used was "(exercise OR phys*) AND (cognit* OR executive) AND (child* OR preadolesc*)." The authors of the studies selected for review were contacted for any unpublished data. Randomized controlled trials, which enrolled children between the ages of 7 and 12, with randomization to either normal activity or a structured physical activity intervention consisting of scheduled aerobic exercise, at least once per week, for a period of at least 1 month. Eligible studies must have included a neuropsychological battery of tests that measured at least 1 executive function both before and after the intervention was completed. Two independent reviewers examined the screened studies in detail for potential inclusion. The results of the individual examinations were compared; if any discrepancies were present, a third party analyzed the study to determine if it should be included in the meta-analysis. A total of 18 studies were identified by abstract as candidates for

  7. Neutron activation analysis of monomineral fractions

    International Nuclear Information System (INIS)

    Drykhin, V.I.; Belen'kij, B.V.; Voinkov, D.M.; Il'yasova, K.I.; Lejpinskaya, D.I.; Nedostyp, T.V.

    1977-01-01

    The results are described of the development of an instrumental neutron activation analysis (INAA) of monomineral sulfides (pyrites, pyrrhotites, chalcopyrites and others), quartzites and other minerals, the technique being intended for geochemical investigations. For a multi-element INAA of monomineral sulfides, the optimum irradiation time in a flux of 10 12 to 1.3x10 13 n/cm 2 (neutron field of a nuclear reactor) is 20 to 40 hours, thus ensuring a reliable determination of a great number of elements not lower than 10 -4 %. The time of the induced activity for determining indium in sulfides is 0.5 to 3 min. The actual sensitivity of the method is 10 -4 %. A sensitivity with respect to gold of 0.01 g/t was attained in monominerals after an irradiation of up to 5 min

  8. Selected industrial and environmental applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    1999-01-01

    A review of the applications of Instrumental Neutron Activation Analysis (INAA) in the industrial and environmental fields is given. Detection limits for different applications are also given. (author)

  9. Instrumental neutron activation analysis of soil sample

    International Nuclear Information System (INIS)

    Abdul Khalik Haji Wood.

    1983-01-01

    This paper describes the analysis of soil samples collected from 5 different location around Sungai Lui, Kajang, Selangor, Malaysia. These sample were taken at 22-24 cm from the top of the ground and were analysed using the techniques of Instrumental Neutron Activation Analysis (INAA). The analysis on soil sample taken above 22-24 cm level were done in order to determine if there is any variation in elemental contents at different sampling levels. The results indicate a wide variation in the contents of the samples. About 30 elements have been analysed. The major ones are Na, I, Cl, Mg, Al, K, Ti, Ca and Fe. Trace elements analysed were Ba, Sc, V, Cr, Mn, Ga, As, Zn, Br, Rb, Co, Hf, Zr, Th, U, Sb, Cs, Ce, Sm, Eu, Tb, Dy, Yb, Lu and La. (author)

  10. Analysis of atmospheric particulate samples via instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    1990-01-01

    Instrumental neutron activation analysis (INAA) is a powerful analytical technique for the elemental characterization of atmospheric particulate samples. It is a true multielement technique with adequate sensitivity to determine 30 to 40 elements in a sample of atmospheric particulate material. Its nondestructive nature allows sample reanalysis by the same or a different analytical technique. In this paper as an example of the applicability of INAA to the study of atmospheric particulate material, a study of the emissions from municipal incinerators is described

  11. Examples of analysis by activation; Exemples d'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    We were used various nuclear reactions to do some analysis by neutron or by X-ray activation. We used the french reactor core Zoe as neutrons sources and an Allis-Chalmers betatron as X-rays sources for the dosage of the light elements. The described processes were revealed fast and particularly useful for determination of traces. The fact that most of them don't require any chemical operations, is especially substantial when the solubilization of the sample is difficult. (M.B.) [French] Nous avons utilise des reactions nucleaires diverses pour effectuer des analyses par activation neutronique ou par rayon X. Nous avons utilise la pile francaise Zoe comme sources de neutrons et un betatron Allis-Chalmers comme sources de rayons X pour le dosage des elements legers. Les procedes decrits se sont reveles rapides et particulierement utiles dans la determination des traces. Le fait que, pour la plupart, ils n'exigent pas d'operations chimiques, est particulierement appreciable lorsque la solubilisation des echantillons est difficile. (M.B.)

  12. Altered sensorimotor activation patterns in idiopathic dystonia-an activation likelihood estimation meta-analysis of functional brain imaging studies

    DEFF Research Database (Denmark)

    Løkkegaard, Annemette; Herz, Damian M; Haagensen, Brian Numelin

    2016-01-01

    Dystonia is characterized by sustained or intermittent muscle contractions causing abnormal, often repetitive, movements or postures. Functional neuroimaging studies have yielded abnormal task-related sensorimotor activation in dystonia, but the results appear to be rather variable across studies....... Further, study size was usually small including different types of dystonia. Here we performed an activation likelihood estimation (ALE) meta-analysis of functional neuroimaging studies in patients with primary dystonia to test for convergence of dystonia-related alterations in task-related activity...... postcentral gyrus, right superior temporal gyrus and dorsal midbrain. Apart from the midbrain cluster, all between-group differences in task-related activity were retrieved in a sub-analysis including only the 14 studies on patients with focal dystonia. For focal dystonia, an additional cluster of increased...

  13. Multi trace element analysis of dry biological materials by neutron activation analysis including a chemical group separation

    International Nuclear Information System (INIS)

    Weers, C.A.

    1980-07-01

    Multi-element analysis of dry biological material by neutron activation analysis has to include radiochemical separation. The evaporation process is described in terms of the half-volume. The pretreatment of the samples and the development of the destruction-evaporation apparatus are described. The successive adsorption steps with active charcoal, Al 2 O 3 and coprecipitation with Fe(OH) 3 are described. Results obtained for standard reference materials are summarized. (G.T.H.)

  14. Applying an Activity System to Online Collaborative Group Work Analysis

    Science.gov (United States)

    Choi, Hyungshin; Kang, Myunghee

    2010-01-01

    This study determines whether an activity system provides a systematic framework to analyse collaborative group work. Using an activity system as a unit of analysis, the research examined learner behaviours, conflicting factors and facilitating factors while students engaged in collaborative work via asynchronous computer-mediated communication.…

  15. Spatiotemporal Data Mining, Analysis, and Visualization of Human Activity Data

    Science.gov (United States)

    Li, Xun

    2012-01-01

    This dissertation addresses the research challenge of developing efficient new methods for discovering useful patterns and knowledge in large volumes of electronically collected spatiotemporal activity data. I propose to analyze three types of such spatiotemporal activity data in a methodological framework that integrates spatial analysis, data…

  16. 'ACTIV' - a package of codes for charged particle and neutron activation analysis

    International Nuclear Information System (INIS)

    Cincu, Em.; Alexandreanu, B.; Manu, V.; Moisa, V.

    1997-01-01

    The 'ACTIV' Program is an advanced software package dedicated to applications of the thermal neutron and charged particle activation (NAA and CPA) induced reactions. The program is designed to run on personal computers compatible IBM PC-Models XT/AT, 286 or more advanced, operating under DOS version 5.0 or later, on systems with minimum 5 MB of hard disk memory. The package consists of 6 software modules and a Nuclear Data Base comprising physical, nuclear reaction and decay data for: thermal neutron, proton, deuteron and α-particle induced reactions on 15 selected metallic elements; the nuclear reaction data corresponds to the energy range (5-100) MeV. In the first version - ACTIV 1.0 - the set of input data concerns: the sample type, irradiation and measurement conditions, the γ-ray spectrum identification code, selected detection efficiency calibration curve, selected radionuclides, selected standardization method for elemental analysis, version of results. At present, the 'ACTIV' package comprises 6 soft modules for processing the experimental data, which ensure computation of the quantities: radionuclide activities, activation yield data (case of CPA) and elemental concentration by relative and absolute standardization methods. Recently, the software designed to processing complex γ-ray spectra was acquired and installed on our PC 486 (8 MB RAM, 100 MHz). The next step in developing the 'ACTIV' program envisages improving the existing computing codes, completing the data libraries, incorporating a new soft for the direct use of the 'Quantum TM MCA' data, developing modules dedicated to uncertainty computation and optimization of the activation experiments

  17. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  18. Cluster analysis of activity-time series in motor learning

    DEFF Research Database (Denmark)

    Balslev, Daniela; Nielsen, Finn Årup; Frutiger, Sally A.

    2002-01-01

    Neuroimaging studies of learning focus on brain areas where the activity changes as a function of time. To circumvent the difficult problem of model selection, we used a data-driven analytic tool, cluster analysis, which extracts representative temporal and spatial patterns from the voxel...... practice-related activity in a fronto-parieto-cerebellar network, in agreement with previous studies of motor learning. These voxels were separated from a group of voxels showing an unspecific time-effect and another group of voxels, whose activation was an artifact from smoothing. Hum. Brain Mapping 15...

  19. Time regimes optimization of the activation-measurement cycle in neutron activation analysis

    International Nuclear Information System (INIS)

    Szopa, Z.

    1986-01-01

    Criteria of the optimum time conditions of the activation-measurement cycle in neutron activation analysis have been formulated. The optimized functions i.e. the relative precision or the factor of ''merit'' of the analytical signal measured as functions of the cycle time parameters have been proposed. The structure and possibilities of the optimizing programme STOPRC have been presented. This programme is completely written in FORTRAN and takes advantage of the library of standard spectra and fast, stochastic algorithms. The time conditions predicted with the aid of the programme have been discussed and compared with the experimental results for the case of the determination of tungsten in industrial dusts. 31 refs., 4 figs. (author)

  20. Study of interference by double neutron capture in activation analysis

    International Nuclear Information System (INIS)

    Cohen, I.M.; Korob, R.O.; Mila, M.I.; Rocca, H.C.

    1976-06-01

    The characteristics of the interferences by double capture in activation analysis are studied. Calculations of these interferences are performed, based on the corresponding activation functions, for typical irradiation and decay times. The experiments performed with the pairs Ho-Dy and Pt-Au and their results are commented. (author) [es