WorldWideScience

Sample records for multidetector computed tomography

  1. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  2. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  3. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Vallejos, J.; Capunay, Carlos M.; Deviggiano, A.; Carrascosa, Jorge M.

    2007-01-01

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine [es

  4. CASE SERIES Multi-detector computer tomography venography ...

    African Journals Online (AJOL)

    in the curved coronal plane with particular reference to the course of the common and external iliac veins through the pelvis. Axial venous. Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with ...

  5. Impact of multi-detector row computed tomography on the tactics of cardiovascular surgery. From qualitative evaluation to quantitative assessment

    International Nuclear Information System (INIS)

    Imagawa, Hiroshi; Kawachi, Kanji; Takano, Shinji

    2005-01-01

    We assessed the role of multi-detector row computed tomography in cardiovascular surgery. The efficacy of multi-detector row computed tomography was assessed concerning the graft patency of coronary artery bypass, arterial atheromatous degeneration, small vessel imaging, and left ventricular volume measurement. Images were reconstructed using both the volume-rendering and the maximum-intensity-profile methods. Arterial atherosclerotic degeneration was assessed by aortic wall volume and aortic calcification volume. In the assessment of bypass graft patency, multidetector row computed tomography showed a 98% correct positive ratio with sensitivity and specificity of 98% and 100%, respectively. Atheromatous degeneration showed matching results in more than 70% of cases compared with intraoperative findings. More than 92% of arterial branches with diameters of 3 mm or greater were detected by preoperative multi-detector row computed tomography images, though only 6% of branches with diameters of 2 mm or less could be visualized. There was a positive linear correlation between left ventricular volumes determined by multi-detector row computed tomography and those calculated from cine angiography. Multi-detector row computed tomography clearly visualized coronary bypass grafts and aortic arterial branches, providing detailed vascular images. Atheromatous degeneration assessed by multi-detector row computed tomography was equivalent with intraoperative findings in more than 70% of cases. Left ventricular volumes measured by multi-detector row computed tomography correlated closely with those determined by cine-angiography. Multidetector row computed tomography is an efficient and promising modality in cardiovascular surgery. (author)

  6. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  7. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    International Nuclear Information System (INIS)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes

    2015-01-01

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  8. The value of unenhanced multi-detector computed tomography ...

    African Journals Online (AJOL)

    Introduction: Unenhanced computed tomography (CT) is used to detect urinary tract calculi with high accuracy. The development of multi-detector CT (MDCT) allows reconstructions in coronal, sagittal and oblique directions. Objective: To compare MDCT with three-dimensional (3D) ultrasound (US) imaging in evaluating ...

  9. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  10. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  11. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  12. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  13. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Møller, Daniel V

    2009-01-01

    BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic echocard......BACKGROUND: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic...... echocardiography (TTE). MATERIALS AND METHODS: Sixty-four patients with known or suspected coronary artery disease underwent ECG-gated 64-slice MDCT and TTE. Regional left ventricular contractile function was measured by percent systolic wall thickening (SWT) in 16 myocardial segments using MDCT, and compared...

  14. Multidetector computed tomography of jaw lesions in children and adolescents

    International Nuclear Information System (INIS)

    Gadodia, A.; Seith, A.; Sharma, R.; Choudhury, A.R.; Bhutia, O.; Gupta, A.

    2010-01-01

    Full text: Jaw lesions in paediatric and adolescent population are uncommon and can arise in odontogenic or non-odontogenic tissues. With the advent of multidetector computed tomography (MDCT), algorithm for imaging jaw lesions has changed dramatically. This pictorial essay describes the imaging appearance of commonly encountered jaw lesions in children and adolescents with emphasis on MDCT findings

  15. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  16. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  17. Multi-detector computed tomography (MDCT imaging of cardiovascular effects of pulmonary embolism: What the radiologists need to know

    Directory of Open Access Journals (Sweden)

    Mohamed Aboul-fotouh E. Mourad

    2017-09-01

    Full Text Available Background: Patients with pulmonary embolism have high mortality and morbidity rate due to right heart failure and circulatory collapse leading to sudden death. Multi-detector computed tomography MDCT can efficiently evaluate the cardiovascular factors related to pulmonary embolism. Objectives: To evaluate the diagnostic accuracy of multi-detector computed tomography (MDCT in differentiation of between sever and non-severe pulmonary embolism groups depending on the associated cardiovascular parameters and create a simple reporting system. Patients & methods: Prospective study contained 145 patients diagnosed clinically pulmonary embolism. All patients were examined by combined electrocardiographically gated computed tomography pulmonary angiography-computed tomography venography (ECG-CTPA-CTV using certain imaging criteria in a systematic manner. Results: Our study revealed 95 and 55 non-severe and severe pulmonary embolism groups respectively. Many cardiovascular parameters related to pulmonary embolism shows significant p value and can differentiate between sever and non-severe pulmonary embolism patients include pulmonary artery diameter, intraventricular septum flattening, bowing, superior vena cava and Azygos vein diameters, right and left ventricular diameters. Conclusion: Multi-detector computed tomography (MDCT can be valuable to assess the severity of pulmonary embolism using the related cardiovascular parameters and leading the management strategy aim for best outcome. Keywords: Pulmonary embolism, MDCT, Cardiovascular, Computed tomography venography

  18. Prognostic implications of nonobstructive coronary plaques in patients with non-ST-segment elevation myocardial infarction: a multidetector computed tomography study

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Kühl, Jørgen T

    2011-01-01

    We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events.......We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events....

  19. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings

    International Nuclear Information System (INIS)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da; Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos

    2014-01-01

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  20. Multiplanar and two-dimensional imaging of central airway stenting with multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Ozgul Mehmet

    2012-08-01

    Full Text Available Abstract Background Multidetector computed tomography (MDCT provides guidance for primary screening of the central airways. The aim of our study was assessing the contribution of multidetector computed tomography- two dimensional reconstruction in the management of patients with tracheobronchial stenosis prior to the procedure and during a short follow up period of 3 months after the endobronchial treatment. Methods This is a retrospective study with data collected from an electronic database and from the medical records. Patients evaluated with MDCT and who had undergone a stenting procedure were included. A Philips RSGDT 07605 model MDCT was used, and slice thickness, 3 mm; overlap, 1.5 mm; matrix, 512x512; mass, 90 and kV, 120 were evaluated. The diameters of the airways 10 mm proximal and 10 mm distal to the obstruction were measured and the stent diameter (D was determined from the average between D upper and D lower. Results Fifty-six patients, 14 (25% women and 42 (75% men, mean age 55.3 ± 13.2 years (range: 16-79 years, were assessed by MDCT and then treated with placement of an endobronchial stent. A computed tomography review was made with 6 detector Philips RSGDT 07605 multidetector computed tomography device. Endobronchial therapy was provided for the patients with endoluminal lesions. Stents were placed into the area of stenosis in patients with external compression after dilatation and debulking procedures had been carried out. In one patient the migration of a stent was detected during the follow up period by using MDCT. Conclusions MDCT helps to define stent size, length and type in patients who are suitable for endobronchial stinting. This is a non-invasive, reliable method that helps decisions about optimal stent size and position, thus reducing complications.

  1. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  2. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  3. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Martin Lopez, Elba; Capunay, Carlos; Deviggiano, Alejandro; Vallejos, Javier; Carrascosa, Jorge

    2009-01-01

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors) [es

  4. Multi-detector computed tomography of acute abdomen

    International Nuclear Information System (INIS)

    Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Marincek, Borut; University Hospital of Zurich

    2005-01-01

    Acute abdominal pain is one of the most common causes for referrals to the emergency department. The sudden onset of severe abdominal pain characterising the ''acute abdomen'' requires rapid and accurate identification of a potentially life-threatening abdominal pathology to provide a timely referral to the appropriate physician. While the physical examination and laboratory investigations are often non-specific, computed tomography (CT) has evolved as the first-line imaging modality in patients with an acute abdomen. Because the new multi-detector CT (MDCT) scanner generations provide increased speed, greater volume coverage and thinner slices, the acceptance of CT for abdominal imaging has increased rapidly. The goal of this article is to discuss the role of MDCT in the diagnostic work-up of acute abdominal pain. (orig.)

  5. Multidetector computed tomography of the renal arteries in vascular emergencies

    International Nuclear Information System (INIS)

    Regine, Giovanni; Stasolla, Alessandro; Miele, Vittorio

    2007-01-01

    Multidetector computed tomography (MDCT) has drastically changed the diagnostic imaging protocol in both traumatic and non-traumatic vascular emergencies, replacing almost completely the traditional primary role of catheter angiography. MDCT is a well-established tool for the elective evaluation of stenoses, malformations, and dysplasias in the settings of renovascular hypertension, but probably less used in the settings of acute traumatic and non-traumatic clinical situations. The aim of this review is to define the role of MDCT in renal arteries emergencies

  6. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    International Nuclear Information System (INIS)

    Monteiro, Mario L.R.; Goncalves, Allan C.P.; Silva, Carla T.M.; Moura, Janete P.; Ribeiro, Carolina S.; Gebrim, Eloisa M.M.S.; Universidade de Sao Paulo; Universidade de Sao Paulo

    2008-01-01

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values (±SD) were 64.47% ± 6.06% and 49.44% ± 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p 60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  7. Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Mário L. R. Monteiro

    2008-01-01

    Full Text Available OBJECTIVES: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index, calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. RESULTS: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy met the inclusion criteria for the study. The mean Barrett's index values (± SD were 64.47% ± 6.06% and 49.44% ± 10.94%in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy.

  8. Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Zacho, Mette; Damgaard, Sune; Lilleoer, Nikolaj Thomas

    2012-01-01

    The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related...

  9. Communication between the right and circumflex coronary arteries discovered incidentally by multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Se Hwan; Kim, Eui Jong; Woo, Jong Shin; Kim, Soo Joong; Youn, Hyo Chul; Oh, Joo Hyeong [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2016-09-15

    Intercoronary communication is a rare congenital coronary anomaly. We present a case of a 48-year-old man with an incidentally discovered communication between the right and circumflex coronary arteries, who was admitted with chest tightness and exertional dyspnea. The initial diagnosis was made using electrocardiogram-gated multidetector computed tomography.

  10. Multidetector Computed Tomography and Neuroendocrine Pancreaticoduodenal Tumors

    International Nuclear Information System (INIS)

    Rappeport, E.D.; Palnaes Hansen, C.; Kjaer, A.; Knigge, U.

    2006-01-01

    Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs). Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies. Results: Patients with surgery : 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery : In 4 out of 9 patients, no NPTs were identified at MDCT. Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT

  11. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Directory of Open Access Journals (Sweden)

    Carlos Fernando de Mello Júnior

    2016-06-01

    Full Text Available Abstract Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  12. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    International Nuclear Information System (INIS)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de; Reboucas, Rafael Batista

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  13. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Energy Technology Data Exchange (ETDEWEB)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil); Reboucas, Rafael Batista, E-mail: severinoaires@hotmail.com [Faculdade de Ciencias Medicas da Paraiba, Joao Pessoa, PB (Brazil)

    2016-05-15

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  14. Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Hyoung Jung; Lee, Dong Ho; Lim, Joo Won; Ko, Young Tae

    2009-01-01

    Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma

  15. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard

    2015-01-01

    To assess the relationship between epicardial coronary artery stenosis severity and the corresponding regional transmural perfusion at rest and during adenosine stress, using multidetector computed tomography (MDCT). We evaluated the relationship between the severity of coronary artery diameter...

  16. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  17. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    International Nuclear Information System (INIS)

    Palas, J.; Matos, A.P.; Ramalho, M.; Mascarenhas, V.; Heredia, V.

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  18. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  19. A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Roberto Moraes Bastos

    2011-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair. METHODS: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase. RESULTS: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams. CONCLUSION: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

  20. [The different manifestations of pulmonary aspergillosis: multidetector computed tomography findings].

    Science.gov (United States)

    Koren Fernández, L; Alonso Charterina, S; Alcalá-Galiano Rubio, A; Sánchez Nistal, M A

    2014-01-01

    Pulmonary aspergillosis is a fungal infection usually caused by inhaling Aspergillus fumigatus spores. However, when we talk about aspergillosis, we normally refer to the spectrum of clinical and radiological findings that depend directly on the patient's immune status, on the prior existence of lung disease, and on the virulence of the infective organism. There are four types of pulmonary aspergillosis (aspergilloma, allergic bronchopulmonary aspergillosis, chronic necrotizing pulmonary aspergillosis, and invasive aspergillosis), and each type has its own distinct radiologic findings. We review the signs of pulmonary aspergillosis on multidetector computed tomography and we correlate them with patients' symptoms and immune responses. Likewise, we discuss the differential diagnoses. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  1. Multidetector computed tomography has replaced conventional intravenous excretory urography in imaging of the kidneys: A scoping review of multidetector computed tomography findings in renal tuberculosis

    Directory of Open Access Journals (Sweden)

    Ntombizakhona B.A. Mthalane

    2018-02-01

    Full Text Available Background: Tuberculosis (TB is a worldwide infectious disease burden, especially in non-developed countries, with increased morbidity and mortality among human immunodeficiency virus (HIV-infected patients. Extrapulmonary TB is rare and renal TB is one of the commonest manifestations. The end result of renal TB is end-stage renal disease; however, this can be avoided if the diagnosis is made early. The diagnosis of renal TB is challenging because of the non-specific presentation and low sensitivity of clinical tests. Although the sequel of TB infection in the kidney causes varying manifestations depending on the stage of the disease, multidetector computed tomography (MDCT is capable of demonstrating early findings. We performed a 20-year scoping review of MDCT findings in renal TB to promote awareness. Aim: To identify specific MDCT imaging characteristics of renal TB, promote early diagnosis and increase awareness of the typical imaging features. Methods and material: We searched published and unpublished literature from 1997 to 2017 using a combination of search terms on electronic databases. We followed the Joanna Briggs Institute guidelines. Results: A total of 150 articles were identified, of which 145 were found through electronic search engines and 5 were obtained from grey literature. Seventy-nine articles that fulfilled our inclusion criteria were reviewed. These included original research, case reports, literature review, organisational reports and grey literature. Conclusion: Multidetector computed tomography can reproduce images comparable with intravenous excretory urography; together with advantages of being able to better assess the renal parenchyma and surrounding spaces, it is important in suggesting the diagnosis of renal TB and clinicians should consider including MDCT when investigating patients with recurrent urinary tract infection not responding to usual antimicrobial therapy.

  2. Multi-detector row computed tomography and blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, Mariano; Pinto, Antonio; Pedrosa, Ivan; Sparano, Amelia; Romano, Luigia

    2008-01-01

    Blunt chest trauma is a significant source of morbidity and mortality in industrialized countries. The clinical presentation of trauma patients varies widely from one individual to another and ranges from minor reports of pain to shock. Knowledge of the mechanism of injury, the time of injury, estimates of motor vehicle accident velocity and deceleration, and evidence of associated injury to other systems are all salient features to provide for an adequate assessment of chest trauma. Multi-detector row computed tomography (MDCT) scanning and MDCT-angiography are being used more frequently in the diagnosis of patients with chest trauma. The high sensitivity of MDCT has increased the recognized spectrum of injuries. This new technology can be regarded as an extremely valuable adjunct to physical examination to recognize suspected and unsuspected blunt chest trauma

  3. Visibility of sutures of the orbit and periorbital region using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gufler, Hubert; Preis, Markus; Koesling, Sabrina [Dept. of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Halle (Germany)

    2014-12-15

    Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube current from 25 to 370 mAs, depending on the CT indication. The visibility of sutures was estimated according to a 4-point scale from 'not visible to well visible' The chi-squared test was used to test the association of the visibility of sutures with the slice thickness, tube current, and age of patients. Statistical significance was assumed at p < 0.05. Overall, best visibility was found for the sutura frontozygomatica (98%), sutura frontonasalis (88.5%), and sutura sphenozygomatica (71.5%), followed by the sutura zygomaticomaxillaris (65.8%), sutura temporozygomatica (41.8%), sutura frontomaxillaris (44.5%), and sutura sphenofrontalis (31%). Poor visibility was found for the sutura frontolacrimalis (16.8%) and sutura frontoethmoidalis (1.3%). The sutura ethmoidomaxillaris, sutura lacrimomaxillaris, and sutura ethmoidolacrimalis were not visible. Although the sutures of the superior, lateral, and inferior orbit are well visible, those of the medial orbit are poorly visible on CT scans.

  4. Multidetector computer tomography in the pancreatic adenocarcinoma assessment: an update

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    2016-11-01

    Full Text Available Abstract Ductal adenocarcinoma of the pancreas is one of the most aggressive forms of cancer, with only a minority of cases being resectable at the moment of their diagnosis. The accurate detection and characterization of pancreatic carcinoma is very important for patient management. Multidetector-row computed tomography (MDCT has become the cross-sectional modality of choice in the diagnosis, staging, treatment planning, and follow-up of patients with pancreatic tumors. However, approximately 11% of ductal adenocarcinomas still remain undetected at MDCT because of the lack of attenuation gradient between the lesion and the adjacent pancreatic parenchyma. In this systematic literature review we investigate the current evolution of the CT technique, limitations, and perspectives in the evaluation of pancreatic carcinoma.

  5. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings; Classificacao de Bosniak das lesoes cisticas renais segundo achados na tomografia computadorizada multidetectores

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da, E-mail: maiachristiana@globo.com [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil); Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos [Clinica de Medicina Nuclear e Radiologia de Maceio (MedRadiUS), Maceio, AL (Brazil)

    2014-03-15

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  6. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  7. Multidetector computed tomography diagnosis of gastric volvulus through the foramen of Morgagni.

    Science.gov (United States)

    Lecouvet, S; Coulier, B; Pierard, F; Gogoase, M; Coppens, J P; Van Hoof, M

    2014-01-01

    Morgagni hernia is considered to be the rarest form of all diaphragmatic hernias. It develops through a congenital defect in the retrosternal area. Usually asymptomatic, this entity can lead to life-threatening complications such as incarceration, strangulation or volvulus of the herniated viscus. We hereby report a rare case of organoaxial gastric volvulus producing through the foramen of Morgagni in a 78-year-old woman. The full diagnosis was made by upper gastro-intestinal series and multidetector computed tomography (MDCT). The basic anatomy, physiopathology, diagnostic methods, complications and surgical treatment of Morgagni hernia are briefly reviewed.

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Energy Technology Data Exchange (ETDEWEB)

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  9. Prevalence of extra-cardiac findings on studies of noninvasive coronary angiography multidetector computed tomography 64 rows

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Capunay, Carlos M.; Deviggiano, A.; Melendez, F.; Carrascosa, Jorge M.; Garcia, M.

    2007-01-01

    The aim of this paper is to show the importance of evaluating in a full form images obtained from a studio of noninvasive coronary angiography by multidetector computed tomography (AC-TCMD). 90 users of AC-TCMD were evaluated retrospectively conducted between October 2006 and April 2007 with a multidetector tomography of 64-rows(Phillips Medical Systems) . The images were reprocessed with a maximum field of vision and determined the presence of extra-cardiac findings, which were classified according to their impact on the management and treatment of patient at 3 degrees: low, medium and high grade. The studies were assessed jointly by a cardiologist and a radiologist qualified for cardiac and corporal evaluation. Extra-cardiac findings were identified in 58 patients. There were 38 patients with findings of low grade, 31 medium grade and 1 high grade. It was recommended to 16 patients its monitoring by images on reasonable period of time [es

  10. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  11. Association between diabetes and different components of coronary atherosclerotic plaque burden as measured by coronary multidetector computed tomography.

    Science.gov (United States)

    Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian

    2009-08-01

    The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP

  12. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  13. Differentiation between tuberculosis and leukemia in abdominal and pelvic lymph nodes: evaluation with contrast-enhanced multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Ge Zhang

    2015-03-01

    Full Text Available PURPOSE: To compare the characteristics of tubercular vs. leukemic involvement of abdominopelvic lymph nodes using multidetector computed tomography (CT. MATERIALS AND METHODS: We retrospectively reviewed multidetector computed tomography features including lymph node size, shape, enhancement patterns, and anatomical distribution, in 106 consecutive patients with newly diagnosed, untreated tuberculosis (55 patients; 52% or leukemia (51 patients; 48%. In patients with leukemia, 32 (62.7% had chronic lymphocytic leukemia, and 19 (37.3% had acute leukemias; of these, 10 (19.6% had acute myeloid leukemia, and 9 (17.6% had acute lymphocytic leukemia. RESULTS: The lower para-aortic (30.9% for tuberculosis, 63.2% for acute leukemias and 87.5% for chronic lymphocytic leukemia and inguinal (9.1% for tuberculosis, 57.9% for acute leukemias and 53.1% for chronic lymphocytic leukemia lymph nodes were involved more frequently in the three types of leukemia than in tuberculosis (both with p <0.017. Tuberculosis showed peripheral enhancement, frequently with a multilocular appearance, in 43 (78.2% patients, whereas patients with leukemia (78.9% for acute myeloid leukemia and acute lymphocytic leukemia, 87.5% for chronic lymphocytic leukemia demonstrated predominantly homogeneous enhancement (both with p <0.017. For the diagnosis of tuberculosis, the analysis showed that a peripheral enhancement pattern had a sensitivity of 78.2%, a specificity of 100%, and an accuracy of 88.7%. For the diagnosis of leukemia, the analysis showed that a homogeneous enhancement pattern was associated with a sensitivity of 84.3%, a specificity of 94.5%, and an accuracy of 89.6%. CONCLUSION: Our findings indicate that the anatomical distribution and enhancement patterns of lymphadenopathy seen on multidetector computed tomography are useful for differentiating between untreated tuberculosis and leukemia of the abdominopelvic lymph nodes.

  14. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    International Nuclear Information System (INIS)

    Ogasawara, Yutaka; Doihara, Hiroyoshi; Shiraiwa, Misaki; Ishihara, Setsuko

    2008-01-01

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  15. Assessment of adult congenital heart disease with multi-detector computed tomography - beyond coronary lumenography

    International Nuclear Information System (INIS)

    Nicol, E.D.; Gatzoulis, M.; Padley, S.P.G.; Rubens, M.

    2007-01-01

    Adult congenital heart disease is an increasingly prevalent condition with more than 135,000 patients affected in England alone. With this increased patient population and an increase in interventional procedures being performed on them, traditional imaging techniques such as cardiac magnetic resonance (CMR) may be unavailable locally or contra-indicated. Cardiac multidetector computed tomography (MDCT) is rapidly emerging as an alternative imaging method for the investigation of these patients and this review highlights the broad application of cardiac MDCT to this population and makes recommendations on the stardardized reporting of complex congenital heart disease

  16. Assessment of adult congenital heart disease with multi-detector computed tomography - beyond coronary lumenography

    Energy Technology Data Exchange (ETDEWEB)

    Nicol, E.D. [Department of Radiology, Royal Brompton Hospital, London (United Kingdom) and Department of Cardiology, Royal Brompton Hospital, London (United Kingdom)]. E-mail: e.nicol@rbht.nhs.uk; Gatzoulis, M. [Adult Congenital Heart Centre and Centre for Pulmonary Hypertension, Royal Brompton Hospital and National Heart and Lung Institute, London (United Kingdom); Padley, S.P.G. [Department of Radiology, Royal Brompton Hospital, London (United Kingdom); Rubens, M. [Department of Radiology, Royal Brompton Hospital, London (United Kingdom)

    2007-06-15

    Adult congenital heart disease is an increasingly prevalent condition with more than 135,000 patients affected in England alone. With this increased patient population and an increase in interventional procedures being performed on them, traditional imaging techniques such as cardiac magnetic resonance (CMR) may be unavailable locally or contra-indicated. Cardiac multidetector computed tomography (MDCT) is rapidly emerging as an alternative imaging method for the investigation of these patients and this review highlights the broad application of cardiac MDCT to this population and makes recommendations on the stardardized reporting of complex congenital heart disease.

  17. Sex differences in aortic valve calcification measured by multidetector computed tomography in aortic stenosis.

    Science.gov (United States)

    Aggarwal, Shivani R; Clavel, Marie-Annick; Messika-Zeitoun, David; Cueff, Caroline; Malouf, Joseph; Araoz, Philip A; Mankad, Rekha; Michelena, Hector; Vahanian, Alec; Enriquez-Sarano, Maurice

    2013-01-01

    Aortic valve calcification (AVC) is the intrinsic mechanism of valvular obstruction leading to aortic stenosis (AS) and is measurable by multidetector computed tomography. The link between sex and AS is controversial and that with AVC is unknown. We prospectively performed multidetector computed tomography in 665 patients with AS (aortic valve area, 1.05±0.35 cm(2); mean gradient, 39±19 mm Hg) to measure AVC and to assess the impact of sex on the AVC-AS severity link in men and women. AS severity was comparable between women and men (peak aortic jet velocity: 4.05±0.99 versus 3.93±0.91 m/s, P=0.11; aortic valve area index: 0.55±0.20 versus 0.56±0.18 cm(2)/m(2); P=0.46). Conversely, AVC load was lower in women versus men (1703±1321 versus 2694±1628 arbitrary units; PAVC load were much greater in men than in women (odds ratio, 5.07; PAVC showed good associations with hemodynamic AS severity in men and women (all r>0.67; PAVC load, absolute or indexed, was higher in men versus women (all P≤0.01). In this large AS population, women incurred similar AS severity than men for lower AVC loads, even after indexing for their smaller body size. Hence, the relationship between valvular calcification process and AS severity differs in women and men, warranting further pathophysiological inquiry. For AS severity diagnostic purposes, interpretation of AVC load should be different in men and in women.

  18. Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography

    DEFF Research Database (Denmark)

    de Knegt, Martina C; Linde, Jesper J; Fuchs, Andreas

    2016-01-01

    To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics...

  19. Multidetector computed tomography-spectrum of blunt chest wall and lung injuries in polytraumatized patients

    Energy Technology Data Exchange (ETDEWEB)

    Peters, S., E-mail: soeren.peters@rub.d [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany); Nicolas, V.; Heyer, C.M. [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany)

    2010-04-15

    Accidental injuries are the leading cause of death in the 15 to 44-year-old age group. Blunt chest trauma is often encountered in these patients and is associated with a mortality of up to 25%. Although conventional radiography still plays an important role in the initial emergency room setting, for follow-up in the intensive care unit, multidetector computed tomography has established itself as the standard imaging method for the evaluation of chest trauma patients. The following review presents salient radiological findings of the chest wall and shoulder girdle, thoracic spine, pleural space, and lung in polytraumatized patients.

  20. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Mario L.R.; Goncalves, Allan C.P.; Silva, Carla T.M.; Moura, Janete P.; Ribeiro, Carolina S.; Gebrim, Eloisa M.M.S. [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Division of Ophthalmology; Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Dept. of Endocrinology; Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Division of Radiology]. E-mail: mlrmonteiro@terra.com.br

    2008-07-01

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values ({+-}SD) were 64.47% {+-} 6.06% and 49.44% {+-} 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p<0.001). Barrett's index sensitivity ranged from 32% to 100%, and Barrett's index specificity ranged from 24% to 100%. The best combination of sensitivity and specificity was 79%/72% for BI=60% (odds ratio: 9.2). Conclusions: Barrett's Index is a useful indicator of dysthyroid optic neuropathy and may contribute to early diagnosis and treatment. Patients with a Barrett's index >60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  1. Role of multidetector computed tomography (MDCT) in diagnosis of ...

    African Journals Online (AJOL)

    Aim of the work: To assess the role of multidetector computed tomographic imaging in the diagnosis of secondary intussusception with pathological leading points in children. Materials and methods: This study is a retrospective study including 12 children referred to the radiodiagnosis department at Alexandria University ...

  2. Multidetector-row computed tomography management of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Yasui, Takahiro; Tanabe, Nobuhiro; Terada, Jiro

    2007-01-01

    The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pulmonary angiography and indirect venography were enrolled. Management included indication of IVC filter for patients with extensive deep venous thrombosis (DVT) in submassive or massive PE. A right ventricular to left ventricular short-axis diameter by MDCT >1.0 was judged as submassive PE. All patients were followed for 1 year. MDCT identified 50 patients with venous thromboembolism and 47 patients had acute PE: 4 were judged as massive, 14 as submassive, and 29 as non-massive by MDCT; 3 patients had DVT alone and 7 patients had caval or iliac DVT. Only 1 patient with massive PE and DVT near the right atrium died of recurrence. No other patients died of PE. Management based on MDCT pulmonary angiography combined with indirect venography is considered to be safe and reliable in patients with suspected acute PE. (author)

  3. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  4. Multidetector computed tomography arteriography in the preoperative assessment of patients with ureteropelvic junction obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Petra [Department of Radiology, Hospital de la Plana, Ctra. de Vila-real a Borriana KM. 0.5, 12540 Vila-real (Spain)]. E-mail: PetraBraun@gmx.de; Guilabert, Jose Pamies [Department of Radiology, Hospital de la Plana, Ctra. de Vila-real a Borriana KM. 0.5, 12540 Vila-real (Spain); Kazmi, Faaiza [Department of Radiology, Penn State Milton S. Hershey Medical Center (United States)

    2007-01-15

    Background: Nowadays, endoscopic management of ureteropelvic junction (UPJ) obstruction is the treatment of choice. However, in the presence of crossing vessels, the success rate of endoscopic management decreases and the risk of hemorrhagic and vascular complications rises. The purpose of this study is to evaluate patients with UPJ obstruction using contrast enhanced multidetector computed tomography (CT) angiography to aid in surgical planning and management. Patients and methods: Between 2001 and 2005, 27 patients (mean age: 43 years; age range: 17-75 years) with UPJ obstruction were studied with multidetector CT angiography. Identification and characterization of crossing vessels was performed with multidirectional images and three-directional reconstructions. Results: 12 patients (44%) were found to have 16 crossing vessels (vessels in contact with the UPJ or within a vicinity of less than 2 mm). Nine of these vessels were arteries and seven were veins. Nine vessels crossed anteriorly, two posteriorly, and one anteromedially. Endopyelotomy was contraindicated in these 12 patients due to the presence of crossing vessels. Eleven out of the 12 patients underwent a pyeloplasty by open surgery or laparoscopy, where the presence of crossing vessels was confirmed. One of the 12 patients did not undergo surgery. Conclusion: Multidetector CT angiography permits an adequate preoperative assessment of patients with UPJ obstruction as it is able to identify the presence and location of crossing vessels. Furthermore, it allows to study in detail the anatomy of the renal area and its vascular variants.

  5. Complications of myocardial infarction on multidetector-row computed tomography of chest

    International Nuclear Information System (INIS)

    Raj, V.; Karunasaagarar, K.; Rudd, J.H.F.; Screaton, N.; Gopalan, D.

    2010-01-01

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  6. Current role of multidetector computed tomography in imaging of wrist injuries.

    Science.gov (United States)

    Syed, Mohd Arif; Raj, Vimal; Jeyapalan, Kanagaratnam

    2013-01-01

    Imaging of the wrist is challenging to both radiologists and orthopedic surgeons. This is primarily because of the complex anatomy/functionality of the wrist and also the fact that many frequent injuries are sustained to the hands. On going developments in multidetector computed tomography (MDCT) technology with its "state of the art" postprocessing capabilities have revolutionized this field. Apart from routine imaging of wrist trauma, it is now possible to assess intrinsic ligaments with MDCT arthrography, thereby avoiding invasive diagnostic arthroscopies. Postoperative wrist imaging can be a diagnostic challenge, and MDCT can be helpful in assessment of these cases because volume acquisition and excellent postprocessing abilities help to evaluate these wrists in any desired plane and thinner slices. This article pictorially reviews the current clinical role of MDCT imaging of wrist in our practice. It also describes arthrography technique and scanning parameters used at our center. Copyright © 2013 Mosby, Inc. All rights reserved.

  7. Complications of myocardial infarction on multidetector-row computed tomography of chest

    Energy Technology Data Exchange (ETDEWEB)

    Raj, V.; Karunasaagarar, K. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Rudd, J.H.F. [Division of Cardiovascular Medicine, University of Cambridge, Cambridge (United Kingdom); Screaton, N. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.co [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom)

    2010-11-15

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  8. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A. [University Medical Center Utrecht and Wilhelmina Children' s Hospital, Department of Radiology, Utrecht (Netherlands)

    2012-02-15

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  9. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A.

    2012-01-01

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  10. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  11. An Unusual Left Ventricular Outflow Pseudoaneurysm: Usefulness of Echocardiography and Multidetector Computed Tomography for Surgical Repair

    International Nuclear Information System (INIS)

    Da Col, Uberto; Ramoni, Enrico; Di Bella, Isidoro; Ragni, Temistocle

    2009-01-01

    Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its imaging assessment is challenging and surgical repair requires complex procedures. An unusual case of LVOT pseudoaneurysm is described. It was detected by transthoracic ecocardiography 7 months after aortic root replacement for acute endocarditis. Multidetector computed tomography (MDCT) confirmed the presence of a pouch located between the aortic root and the right atrium. Computed tomography also detected the origin of the pseudoaneurysm from the muscular interventricular septum of the LVOT, rather below the aortic valve plane. It was repaired with an extracardiac surgical approach, sparing the aortic root bioprosthesis previously implanted. The high-resolution three-dimensional details provided by the preoperative MDCT allowed us to plan a simple and effective surgical strategy.

  12. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  13. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  14. Multidetector computed tomography of urolithiasis. Technique and results; Multidetektor-Computertomografie der Urolithiasis. Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Karul, M.; Regier, M. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Radiologie und Endoskopie; Heuer, R. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Operative Medizin

    2013-02-15

    The diagnosis of acute urolithiasis results from unenhanced multidetector computed tomography (MDCT). This test analyses the functional and anatomical possibility for passing an ureteral calculi, the localization and dimension of which are important parameters for further therapy. Alternatively chronic urolithiasis could be ruled out by magnetic resonance urography (MRU). MRU is the first choice especially in pregnant women and children because of radiation hygiene. Enhanced MDCT must be emphasized as an alternative to intravenous urography (IVU) for diagnosis of complex drainage of urine and suspected disorder of the involved kidney. This review illustrates the principles of different tests and the clinical relevance thereof. (orig.)

  15. MULTIDETECTOR COMPUTED TOMOGRAPHY FOR IDENTIFICATION OF INSTABILITY OF AORTIC ANEURYSM WALL

    Directory of Open Access Journals (Sweden)

    M. V. Vishnyakova Jr.

    2015-01-01

    Full Text Available Background: Aortic aneurysm is characterized by high incidence, polymorphic clinical features and sudden onset of severe complications.Aim: To develop a standard multidetector computed tomography (MDCT protocol for aortic aneurysm examination and image analysis for detection the signs of aortic wall instability.Materials and methods: The data of 279 patients with aortic aneurysm who underwent MDCT examination during 2009–2014 was analyzed to identify aortic wall instability signs.Results: Complicated course of aortic aneurysm was observed in 100 cases (36%. The most common sign of aortic wall instability was aortic dissection. According to our results, a new definition of aortic aneurysm complications was elaborated. It included signs of aortic wall instability with incomplete and/or complete disruption of aortic wall layers. A scheme of the most common patterns of aortic wall abnormalities was proposed, allowing a radiologist to reach high accuracy in characterizing this pathology.Conclusion: A dedicated MDCT protocol for aortic aneurysm detection and image analysis can increase quality of radiologic assessment of aneurysm wall allowing to approach to the level of histological accuracy.

  16. Findings in multidetector computed tomography in the diagnosis of hepatocellular carcinoma in patients with cirrhosis and correlation with pathology of liver explants

    International Nuclear Information System (INIS)

    Haberman, D.; Castignola, M.; Mela, M.; Paladini, H.; Santilli, J.P.; Gruz, F.; Gondolesi, G.

    2013-01-01

    Objectives: To describe the imagenological behavior of hepatocellular carcinoma in cirrhotic patients using a dynamic multidetector computed tomography (MDCT) technique, and correlate these findings with histological tumor grades. Materials and methods: A retrospective, descriptive observational study was conducted to evaluate 51 nodules in 32 liver transplant patients diagnosed with liver cirrhosis. The pathology of liver explants was used as a reference. Nodules with hepatocellular carcinoma histopathology were retrospectively analyzed by computed tomography scans performed pre-transplant. Using a dynamic multidetector computed tomography technique, we evaluated the most common imagenological behavior reported in the literature: arterial enhancement, washout, capsule, and intratumoral arterial vessels. Results: Forty-six of 51 (90%) tumors showed arterial enhancement. Of the 46 tumors with arterial enhancement, 39 (85%) had washout in portal-late phase. Five of 51 (10%) were hypovascular. Twenty-two of 51 (43%) had capsule and 12 of 51 (24%) showed intratumoral arterial vessels. The more frequent image combination was the combination of arterial enhancement and washout (39 of 51 tumors or 76%). The most frequent histological grade was II (35 of 51 tumors or 69%). Statistically significant relationships were found between histological grade tumors and imagenological behavior: arterial enhancement and hypovascular. Conclusion: In our population, arterial enhancement with washout in portal-late phases was observed in most of the tumors. Our results are consistent with previously reported studies, demonstrating the high reliability of this imaging pattern for the diagnosis of hepatocellular carcinoma. (authors) [es

  17. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni; Scaglione, Mariano

    2008-01-01

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections

  18. Anatomic evaluation of the xiphoid process with 64-row multidetector computed tomography

    International Nuclear Information System (INIS)

    Akin, Kayihan; Kosehan, Dilek; Topcu, Adem; Koktener, Asli

    2011-01-01

    The aim of this study was to evaluate the interindividual variations of the xiphoid process in a wide adult group using 64-row multidetector computed tomography (MDCT). Included in the study were 500 consecutive patients who underwent coronary computed tomography angiography. Multiplanar reconstruction (MPR), maximum intensity projection (MIP) images on coronal and sagittal planes, and three-dimensional volume rendering (VR) reconstruction images were obtained and used for the evaluation of the anatomic features of the xiphoid process. The xiphoid process was present in all patients. The xiphoid process was deviated ventrally in 327 patients (65.4%). In 11 of these 327 patients (2.2%), ventral curving at the end of the xiphoid process resembled a hook. The xiphoid process was aligned in the same axis as the sternal corpus in 166 patients (33.2%). The tip of the xiphoid process was curved dorsally like a hook in three patients (0.6%). In four patients (0.8%), the xiphoid process exhibited a reverse S shape. Xiphoidal endings were single in 313 (62.6%) patients, double in 164 (32.8%), or triple in 23 (4.6%). Ossification of the cartilaginous xiphoid process was fully completed in 254 patients (50.8 %). In total, 171 patients (34.2%) had only one xiphoidal foramen and 45 patients (9%) had two or more foramina. Sternoxiphoidal fusion was present in 214 of the patients (42.8%). Significant interindividual variations were detected in the xiphoid process. Excellent anatomic evaluation capacity of MDCT facilitates the detection of variations of the xiphoid process as well as the whole ribcage. (orig.)

  19. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    Science.gov (United States)

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  20. Multidetector Computed Tomography of Cervical Spine Fractures in Ankylosing Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toeoeloe Trauma Center (Finland). Dept. of Radiology

    2004-11-01

    Purpose: To analyze multidetector computed tomography (MDCT) cervical spine findings in trauma patients with advanced ankylosing spondylitis (AS). Material and Methods: Using PACS, 2282 cervical spine MDCT examinations requested by emergency room physicians were found during a period of 3 years. Of these patients, 18 (16 M, aged 41-87, mean 57 years) had advanced AS. Primary imaging included radiography in 12 and MRI in 11 patients. Results: MDCT detected one facet joint subluxation and 31 fractures in 17 patients: 14 transverse fractures, 8 spinous process fractures, 2 Jefferson's fractures, 1 type I and 2 type II odontoid process fractures, and 1 each: atlanto-occipital joint fracture and C2 laminar fracture plus isolated transverse process and facet joint fractures. Radiographs detected 48% and MRI 60% of the fractures. MRI detected all transverse and odontoid fractures, demonstrating spinal cord abnormalities in 72%. Conclusion: MDCT is superior to plain radiographs or MRI, showing significantly more injuries and yielding more information on fracture morphology. MRI is valuable, however, in evaluating the spinal cord and soft-tissue injuries. Fractures in advanced AS often show an abnormal orientation and are frequently associated with spinal cord injuries. In these patients, for any suspected cervical spine injuries, MDCT is therefore the imaging modality of choice.

  1. Thoracic Injuries in earthquake-related versus non-earthquake-related trauma patients: differentiation via Multi-detector Computed Tomography

    Science.gov (United States)

    Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng

    2011-01-01

    PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; pchest (45/143 vs. 11/66 patients, RR = 1.9; ptraumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386

  2. Nutcracker or left renal vein compression phenomenon: multidetector computed tomography findings and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar i Calabria, Hug; Quiroga Gomez, Sergi; Sebastia Cerqueda, Carmen; Boye de la Presa, Rosa; Miranda, Americo; Alvarez-Castells, Agusti [Hospitals Universitaris Vall D' Hebron, Institut de Diagnostic Per La Imatge, Servei De Radiodiagnostic, Barcelona (Spain)

    2005-08-01

    The use of multidetector computed tomography (MDCT) in routine abdominal explorations has increased the detection of the nutcracker phenomenon, defined as left renal vein (LRV) compression by adjacent anatomic structures. The embryology and anatomy of the nutcracker phenomenon are relevant as a background for the nutcracker syndrome, a rare cause of hematuria as well as other symptoms. MDCT examples of collateral renal vein circulation (gonadal, ureteric, azygous, lumbar, capsular) and aortomesenteric (anterior) and retroaortic (posterior) nutcracker phenomena in patients with no urologic complaint are shown as well as studies performed on patients with gross hematuria of uncertain origin. Incidental observation of collateral veins draining the LRV in abdominal MDCT explorations of asymptomatic patients may be a sign of a compensating nutcracker phenomenon. Imbalance between LRV compression and development of collateral circulation may lead to symptomatic nutcracker syndrome. (orig.)

  3. Nutcracker or left renal vein compression phenomenon: multidetector computed tomography findings and clinical significance

    International Nuclear Information System (INIS)

    Cuellar i Calabria, Hug; Quiroga Gomez, Sergi; Sebastia Cerqueda, Carmen; Boye de la Presa, Rosa; Miranda, Americo; Alvarez-Castells, Agusti

    2005-01-01

    The use of multidetector computed tomography (MDCT) in routine abdominal explorations has increased the detection of the nutcracker phenomenon, defined as left renal vein (LRV) compression by adjacent anatomic structures. The embryology and anatomy of the nutcracker phenomenon are relevant as a background for the nutcracker syndrome, a rare cause of hematuria as well as other symptoms. MDCT examples of collateral renal vein circulation (gonadal, ureteric, azygous, lumbar, capsular) and aortomesenteric (anterior) and retroaortic (posterior) nutcracker phenomena in patients with no urologic complaint are shown as well as studies performed on patients with gross hematuria of uncertain origin. Incidental observation of collateral veins draining the LRV in abdominal MDCT explorations of asymptomatic patients may be a sign of a compensating nutcracker phenomenon. Imbalance between LRV compression and development of collateral circulation may lead to symptomatic nutcracker syndrome. (orig.)

  4. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  5. Right top pulmonary vein: Evaluation with 64 section multidetector computed tomography

    International Nuclear Information System (INIS)

    Arslan, Gokhan; Dincer, Elvan; Kabaalioglu, Adnan; Ozkaynak, Can

    2008-01-01

    Purpose: To evaluate the incidence and anatomic features of the rare variant of the pulmonary veins named 'right top pulmonary vein' as depicted with 64 section multidetector computed tomography (MDCT). Materials and methods: MDCT of 610 patients obtained over 12 months period for diagnosis of suspected thoracic or cardiac pathology were routinely reviewed in transverse and 3D images. The frequency of right top pulmonary vein (RTPV) was determined and anatomic features were also documented. Results: Right top pulmonary vein (RTPV) is a supernumerary vein arising from the roof of the right part of the left atrium separately from the orifice of the right superior pulmonary vein. It crosses behind the intermediate bronchus and drains mainly posterior segment of the right upper lobe but also receives few subsegmental branches of superior segment of the right lower lobe. It was detected in 2.2% of patients (14/610). The mean diameter of RTPV was 5.1 mm. Conclusion: The RTPV is a rare venous drainage variation of pulmonary veins. It is important to be aware of this anatomic pattern for avoiding misinterpretation of pulmonary venographic findings, inadvertent ablation of pulmonary vein and perioperative bleeding during video assisted thorocoscopic lobectomy

  6. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  7. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G. (Dept. of Radiology, Dept. of Vascular Diagnosis and Research, and Division of Cardiology, Aker Univ. Hospital, Oslo (Norway))

    2008-12-15

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

  8. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G.

    2008-01-01

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome

  9. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  10. Value of Multidetector Computed Tomography in Assessing Blunt Multitrauma Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ahvenjaervi, L.; Mattila, L.; Ojala, R.; Tervonen, O. [Oulu Univ. Hospital (Finland). Dept. of Diagnostic Radiology

    2005-04-01

    Purpose: To find out if multidetector computed tomography (MDCT), using a dedicated trauma protocol, provides sufficient diagnostic information of the injuries of blunt multitrauma patients to enable the planning of treatment for all body compartments. Material and Methods: One-hundred-and-thirty-three patients exposed to high-energy trauma were referred and scanned with the standardized MDCT multitrauma protocol. The imaging protocol consisted of axial scanning of the head and helical scanning of the facial bones, cervical spine, thorax, abdomen, and pelvis. The scanning times were 12 s for the head, 19-21 s for the facial bones and cervical spine (1 mm collimation), and 32-50 s for the thorax, abdomen, and pelvis (2 mm collimation). One-hundred-and-forty milliliters of non-iodinated contrast material (300 mg I/ml) was administered intravenously at 3 ml/s. Results: Ninety-nine of the patients (74%) had at least one finding consistent with trauma. The most frequent findings were in the thorax in 58 patients (44%). Nineteen false-negative findings and two false-positive findings were made. The overall sensitivity of MDCT was 94%, specificity 100%, and accuracy 97%. Conclusion: MDCT is accurate in the assessment of blunt multitrauma patients. The decision to treat the patient can be made on the basis of MDCT with a reasonable level of certainty.

  11. The role of multidetector computed tomography in evaluation of small bowel obstructions

    Directory of Open Access Journals (Sweden)

    Mehmet Fatih İnci

    2013-03-01

    Full Text Available Objective: The purpose of the study was to evaluate therole and additional diagnostic contribution of multi-detectorcomputed tomography (MDCT in patients with acuteabdominal pain caused by small bowel obstruction.Materials and methods: A total of 48 patients who admittedto our hospital with acute abdominal pain and underwentMDCT on suspicion of intestinal obstruction and hadabdominal surgery between January 2012 and October2012 were included to our study. MDCT images were interpretedby two experienced radiologist retrospectively.All clinical data and surgery notes also were evaluated.Patients had surgery due to penetrating or blunt abdominalinjury were excluded.Results: Of these 48 patients, 26 (54.1% were male and22 (45.9% were female. Patients’ ages ranged 25 to 71and mean age was 52±5.4 years. The causes of intestinalobstruction of patients were adhesions for 12 (46.1% patients,tumors for 7 (26.9% patients, external hernias for5 (19.2% patients, internal hernia for 1 (3.9% patient andintussusception for 1 (3.9% patient. A total concordancebetween the MDCT findings and definitive diagnosis wasfound in 26 of 23 cases and the sensitivity and specifityof MDCT in the diagnosis of small bowel obstruction werefound to be 88.5% and 90%, respectively.Conclusion: MDCT is a fast, effective and reliable imagingmethod for preoperative diagnosing small bowel obstructioncauses acute abdominal pain with the advantagesof MDCT such as multi-planar and three-dimensionalreformatted imaging.Key words: Acute abdominal pain, multi-detector computed tomography, small bowel obstruction

  12. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...

  13. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  14. Prospective Electrocardiogram-Gated Multidetector Row Computed Tomography Coronary Angiography. Analysis of Quality Image and Radiation Dose

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Deviggiano, A.; Tajer, C.D.; Vallejos, J.; Goldsmit, A.; Garcia, M.J.

    2009-01-01

    Multidetector row computed tomography coronary angiography (MDCT-CA) has become a useful diagnostic tool for the direct quantification of coronary stenosis, for identifying coronary anomalies and for the assessment of coronary artery bypass grafts. Despite its clinical value has been questioned due to the effective radiation dose (ERD) received by each patient, radiation exposure is similar to other studies. However, different strategies are permanently tested in order to reduce the ERD maintaining adequate and diagnostic image quality. Objectives: To determine the image quality and effective radiation dose (ERD) of prospective electrocardiogram-gated multidetector row computed tomography coronary angiography (PMDCTCA) (the x-ray beam is turned on for only a short portion of diastole) compared to retrospective ECG gating (RMDCTCA) (the x-ray beam is turned on throughout the cardiac cycle) and a preliminary approach of its diagnostic accuracy compared to digital invasive coronary angiography (CA). Material and Methods: Fifty consecutive patients with suspected coronary artery disease and sinus rhythm were evaluated with PMDCT-CA and compared to a control group who underwent RMDCTCA. Image quality was analyzed by two reviewers. Interobserver concordance and ERD were determined. The diagnostic accuracy of PMDCT-CA compared to CA to detect coronary artery stenosis > 50% was assessed in 30 patients. Results: There were no significant differences in the image quality between both groups. Agreement between the reviewers for segment image quality scores was k = 0.92. Mean ERD was 3.5 mSv for PMDCT-CA compared to 9.7 and 12.9 mSv for RMDCT-CA with and without tube current modulation, respectively. Individual analysis including all segments showed that the sensitivity, specificity, positive predictive value and negative predictive value of PMDCT-CA for the detection of coronary stenosis were 94.74%, 81.82%, 90% and 90%, respectively. Conclusion: Our initial experience

  15. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  16. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  17. Multi-Detector Computed Tomography Imaging Techniques in Arterial Injuries

    Directory of Open Access Journals (Sweden)

    Cameron Adler

    2018-04-01

    Full Text Available Cross-sectional imaging has become a critical aspect in the evaluation of arterial injuries. In particular, angiography using computed tomography (CT is the imaging of choice. A variety of techniques and options are available when evaluating for arterial injuries. Techniques involve contrast bolus, various phases of contrast enhancement, multiplanar reconstruction, volume rendering, and maximum intensity projection. After the images are rendered, a variety of features may be seen that diagnose the injury. This article provides a general overview of the techniques, important findings, and pitfalls in cross sectional imaging of arterial imaging, particularly in relation to computed tomography. In addition, the future directions of computed tomography, including a few techniques in the process of development, is also discussed.

  18. Pulmonary Emphysema in Cystic Fibrosis Detected by Densitometry on Chest Multidetector Computed Tomography

    Science.gov (United States)

    Wielpütz, Mark O.; Weinheimer, Oliver; Eichinger, Monika; Wiebel, Matthias; Biederer, Jürgen; Kauczor, Hans-Ulrich; Heußel, Claus P.

    2013-01-01

    Background Histopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF. Methods Volumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subjected to dedicated software. The lung was segmented, low attenuation volumes below a threshold of -950 Hounsfield units were assigned to emphysema volume (EV), and the emphysema index was computed (EI). Results were correlated with forced expiratory volume in 1 s percent predicted (FEV1%), residual volume (RV), and RV/total lung capacity (RV/TLC). Results We show that EV was increased in CF (457±530 ml) compared to non-CF controls (78±90 ml) (PEmphysema in CF was detected from early adolescence (~13 years) and increased with age (rs=0.67, Pemphysema detected by densitometry on chest MDCT is a characteristic pathology that contributes to airflow limitation and may serve as a novel endpoint for monitoring lung disease in CF. PMID:23991177

  19. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  20. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  1. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    International Nuclear Information System (INIS)

    Hoffmann, Hans; Frieler, Katja; Schlattmann, Peter; Hamm, Bernd; Dewey, Marc

    2010-01-01

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm 3 at two time points 25 ± 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P 3 ) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm 3 ). Statins significantly slowed the growth of non-calcified plaques (statin coefficient β = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  2. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  3. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    International Nuclear Information System (INIS)

    Mishra, Anuj; Bhaktarahalli, Jahnavi Narayanaswamy; Ehtuish, Ehtuish F.

    2007-01-01

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading

  4. Congenital varitans and anomalies of the pancreas and pancreatic duct: Imaging by magnetic resonance cholangiopancreaticography and multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Yener, Ouzlem [Dept. of Radiology, Tuerkiye Yueksek Ihtisas Hospital, Ankara (Turkmenistan); Erden, Aysel [Dept. of Radiology, Ankara University School of Medicine, Antalya (Turkmenistan); Tuerkoglu, Mehmet Akif [Dept. of General Surgery, Antalya University School of Medicine, Antalya (Turkmenistan)

    2013-12-15

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography.

  5. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  6. Defining Anatomic Variants of the Coronary Artery in Taiwanese Subjects Using 64-Multidetector-Row Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hung-Jung Wang

    2007-10-01

    Full Text Available The newly developed 64-multidetector-row computed tomography (MDCT prompted us to evaluate coronary angiography using this noninvasive method. We reviewed 281 images of MDCT coronary angiography in Taiwanese. The origins of the coronary arteries were identified from the luminal aspect of the aorta. We described them as seen from the aortic sinus looking toward the cardiac ventricle. The sinus facing the left ventricle was designated sinus 1, and that facing the right ventricle was designated sinus 2. Anatomic variants of the coronary artery were divided into five types according to the structure of the left anterior descending artery, right coronary artery, and left circumflex artery. Of the 281 patients, 275 (97.9% had the type I variant in which the right coronary artery originated from sinus 2. MDCT provides advantages in defining anatomic variation and helps in the planning of clinical therapy or surgery.

  7. Enhanced multidetector-row computed tomography (MDCT) in the diagnosis of acute appendicitis and its severity

    International Nuclear Information System (INIS)

    Miki, Tesshou; Ogata, Seiji; Uto, Mitsunobu; Nakazono, Toshihiro; Urata, Miyuki; Ishibe, Ryouhei; Shinyama, Shin; Nakajo, Masayuki

    2005-01-01

    The purpose of this study was to examine the accuracy of enhanced multidetector-row computed tomography (MDCT) in diagnosing acute appendicitis and its severity. Contrast-enhanced MD-CT 3.5 mm thick images of 23 control patients (A), and 64 patients with surgically proven acute appendicitis including 8 catarrhal (B), 28 phiegmonous (C), and 28 gangrenous (D) appendicitis patients were respectively analyzed. The number of observed major computed tomography (CT) findings for each patient group were as follows: enlarged (≥6 mm in maximum diameter) appendix (A: 5, B: 8, C: 28, D: 28), enhancement of the appendiceal wall; hyper (A: 3, B: 8, C: 27, D: 20), iso (A: 15, B: 0, C: 1, D: 2), hypo (A-C: 0, D: 4), and patched (A-C: 0, D: 2) enhancement, appendicolith (A, B: 0, C: 7, D: 13), dirty fat sign (A: 3, B: 1, C: 21, D: 28), localized ascites (A: 2, B: 0, C: 2, D: 11), and abscess formation (A-C: 0, D: 5). From the combinations of these findings, we could differentiate acute appendicitis from the control normal appendix with an accuracy of 99% and could diagnose the severity of acute appendicitis with accuracies of 92% for catarrhal appendicitis, 84% for phlegmonous appendicitis, and 92% for gangrenous appendicitis. We could also visually reconstruct the entire forms and positions of the appendices from the successive CT findings because of the high-resolution thin-slice MDCT images. MDCT is highly accurate in the diagnosis of acute appendicitis and its severity. (author)

  8. Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment.

    Science.gov (United States)

    Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos

    2018-04-25

    To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres' ethics committees and written informed consent was obtained from all the participants. A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7). In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  9. The story of 12 Chachapoyan mummies through multidetector computed tomography

    International Nuclear Information System (INIS)

    Friedrich, Klaus M.; Nemec, Stefan; Czerny, Christian; Fischer, Helga; Plischke, Sonja; Gahleitner, Andre; Viola, Thomas Bence; Imhof, Herwig; Seidler, Horst; Guillen, Sonja

    2010-01-01

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean ± standard deviation; adults: 145 ± 14 cm, adolescents: 116 ± 17 cm, 2.5 years old child: 72 cm, newborns: 41 ± 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  10. The story of 12 Chachapoyan mummies through multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Klaus M., E-mail: klaus.friedrich@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan, E-mail: stefan.nemec@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Czerny, Christian, E-mail: christian.czerny@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Fischer, Helga, E-mail: helga.fischer@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Plischke, Sonja, E-mail: sonja.plischke@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Gahleitner, Andre, E-mail: andre.gahleitner@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Viola, Thomas Bence, E-mail: bence.viola@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Imhof, Herwig, E-mail: herwig.imhof@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Seidler, Horst, E-mail: horst.seidler@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Guillen, Sonja [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria)

    2010-11-15

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean {+-} standard deviation; adults: 145 {+-} 14 cm, adolescents: 116 {+-} 17 cm, 2.5 years old child: 72 cm, newborns: 41 {+-} 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  11. The normal anatomy and variations of the bronchial arteries: evaluation with multidetector computed tomography.

    Science.gov (United States)

    Yener, Özlem; Türkvatan, Aysel; Yüce, Gökhan; Yener, Ali Ümit

    2015-02-01

    In this study, we aimed to reveal the normal anatomy and variations of the bronchial arterial system and to determine the sex distribution of these variations by retrospectively reviewing the images of patients who underwent thoracal multidetector computed tomographic angiography for various reasons. Multidetector computed tomographic images of a total of 208 patients (151 men; mean age, 59 years) were retrospectively reviewed to assess the normal anatomy and variations of the bronchial arterial system. A total of 531 bronchial arteries (median, 3; minimum, 1; maximum, 5; mean, 2.5) were detected. The number (mean diameter) of the right bronchial arteries were higher than the left bronchial arteries (290 [1.43 mm] and 241 [1.26 mm], respectively; P arteries were higher with men than with women (2.58 [1.45 mm] and 2.47 [1.32 mm], respectively; P artery, and, secondarily (13.46%), the combination of 2 right (1 intercostal-bronchial trunk and 1 bronchial artery) and 1 left bronchial arteries. Seventy-eight ectopic bronchial arteries were detected in 59 cases (28.3%). They most commonly originated from the aortic arch (37.2%), the descending aorta below the level of T6 (35.9%), or the aortic branches (16.7%). The number of right ectopic bronchial arteries was significantly higher than the left ectopic bronchial arteries (50 [64%] vs 28 [36%]; P arteries was statistically higher with men versus women (45 [29.8%] vs 14 [24.6%]; P arteries can vary substantially among individuals. Multidetector computed tomographic angiography enables a detailed road map of the bronchial arterial system to interventional radiologists and thoracic surgeons. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Hans [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Klinikum Brandenburg, Department of Cardiology, Angiology, and Pulmonology, Brandenburg an der Havel (Germany); Frieler, Katja [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Potsdam Institut fuer Klimaforschung, Potsdam (Germany); Schlattmann, Peter [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Hamm, Bernd [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Dewey, Marc [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology (Germany)

    2010-12-15

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm{sup 3} at two time points 25 {+-} 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P < 0.001) increased from baseline (medians/interquartile ranges = 21/15-39, 7/3-20 and 36/16-69 mm{sup 3}) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm{sup 3}). Statins significantly slowed the growth of non-calcified plaques (statin coefficient {beta} = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  13. Left atrial passive emptying function is preserved in patients with permanent atrial fibrillation--a 320-slice multidetector computed tomography study

    DEFF Research Database (Denmark)

    Agner, Bue Fridolin Ross; Kühl, Jørgen Tobias; Kofoed, Klaus Fuglsang

    2014-01-01

    OBJECTIVE: Left atrial (LA) mechanical function is thought to be virtually inexistent in patients with permanent atrial fibrillation (AF). Due to recent advances in multidetector computed tomography (MDCT) technology, it is now possible to acquire images of the entire heart in a single heartbeat....... The objective of this study was to compare individual components of LA function assessed by MDCT in patients with permanent AF and patients in sinus rhythm (SR). METHODS: 320-slice MDCT was performed in 30 patients with permanent AF. Measurements of LA volumes during the cardiac cycle were compared to 30......; 71 vs. 30 ml/m(2), p permanent AF have significantly increased LA volumes throughout the cardiac...

  14. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Schoellchen, Maximilian; Hanken, H.; Precht, C.; Heiland, M. [University Medical Center Hamburg, Department of Oral- and Maxillofacial Surgery, Hamburg (Germany); Henes, F.O.; Adam, G.; Regier, M. [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schoen, G. [University Medical Center Hamburg, Department of Medical Biometry and Epidemiology, Hamburg (Germany); Nagel, H.D. [Science and Technology for Radiology, Buchholz (Germany); Schumacher, U. [University Medical Center Hamburg, Institute of Anatomy, Hamburg (Germany)

    2017-02-15

    To compare multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) regarding radiation, resolution, image noise, and image quality. CBCT and 256-MDCT were compared based on three scan protocols: Standard-dose (∼24 mGy), reduced-dose (∼9 mGy), and low-dose (∼4 mGy). MDCT images were acquired in standard- and high-resolution mode (HR-MDCT) and reconstructed using filtered back projection (FBP) and iterative reconstruction (IR). Spatial resolution in linepairs (lp) and objective image noise (OIN) were assessed using dedicated phantoms. Image quality was assessed in scans of 25 cadaver heads using a Likert scale. OIN was markedly higher in FBP-MDCT when compared to CBCT. IR lowered the OIN to comparable values in standard-mode MDCT only. CBCT provided a resolution of 13 lp/cm at standard-dose and 11 lp/cm at reduced-dose vs. 11 lp/cm and 10 lp/cm in HR-MDCT. Resolution of 10 lp/cm was observed for both devices using low-dose settings. Quality scores of MDCT and CBCT did not differ at standard-dose (CBCT, 3.4; MDCT, 3.3-3.5; p > 0.05). Using reduced- and low-dose protocols, CBCT was superior (reduced-dose, 3.2 vs. 2.8; low dose, 3.0 vs. 2.3; p < 0.001). Using the low-dose protocol, the assessed CBCT provided better objective and subjective image quality and equality in resolution. Similar image quality, but better resolution using CBCT was observed at higher exposure settings. (orig.)

  15. Multidetector computed tomography analysis of benign and malignant nodules in patients with chronic lymphocytic thyroiditis.

    Science.gov (United States)

    Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying

    2016-07-01

    The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (Pbenign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.

  16. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    Science.gov (United States)

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  17. Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.

    Science.gov (United States)

    Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P

    2007-06-01

    To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.

  18. Quantification of Global Left Ventricular Function: Comparison of Multidetector Computed Tomography and Magnetic Resonance Imaging. A Meta-analysis and Review of the Current Literature

    International Nuclear Information System (INIS)

    Vleuten, P.A. van der; Willems, T.P.; Goette, M.J.; Tio, R.A.; Greuter, M.J.; Zijlstra, F.; Oudkerk, M.

    2006-01-01

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI

  19. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  20. Blunt trauma of bone structures of the chest--computed tomography vs multidetector computed tomography.

    Science.gov (United States)

    Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana

    2013-08-01

    Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  1. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  2. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  3. Multidetector computed tomography of the head in acute stroke: predictive value of different patterns of the dense artery sign revealed by maximum intensity projection reformations for location and extent of the infarcted area

    Energy Technology Data Exchange (ETDEWEB)

    Gadda, Davide; Vannucchi, Letizia; Niccolai, Franco; Neri, Anna T.; Carmignani, Luca; Pacini, Patrizio [Ospedale del Ceppo, U.O. Radiodiagnostica, Pistoia (Italy)

    2005-12-01

    Maximum intensity projections reconstructions from 2.5 mm unenhanced multidetector computed tomography axial slices were obtained from 49 patients within the first 6 h of anterior-circulation cerebral strokes to identify different patterns of the dense artery sign and their prognostic implications for location and extent of the infarcted areas. The dense artery sign was found in 67.3% of cases. Increased density of the whole M1 segment with extension to M2 of the middle cerebral artery was associated with a wider extension of cerebral infarcts in comparison to M1 segment alone or distal M1 and M2. A dense sylvian branch of the middle cerebral artery pattern was associated with a more restricted extension of infarct territory. We found 62.5% of patients without a demonstrable dense artery to have a limited peripheral cortical or capsulonuclear lesion. In patients with a 7-10 points on the Alberta Stroke Early Programme Computed Tomography Score and a dense proximal MCA in the first hours of ictus the mean decrease in the score between baseline and follow-up was 5.09{+-}1.92 points. In conclusion, maximum intensity projections from thin-slice images can be quickly obtained from standard computed tomography datasets using a multidetector scanner and are useful in identifying and correctly localizing the dense artery sign, with prognostic implications for the entity of cerebral damage. (orig.)

  4. Gastric cancer: texture analysis from multidetector computed tomography as a potential preoperative prognostic biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Giganti, Francesco; Salerno, Annalaura; Marra, Paolo; Esposito, Antonio; Del Maschio, Alessandro; De Cobelli, Francesco [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); San Raffaele Vita-Salute University, Milan (Italy); Antunes, Sofia [San Raffaele Scientific Institute, Centre for Experimental Imaging, Milan (Italy); Ambrosi, Alessandro [San Raffaele Vita-Salute University, Milan (Italy); Nicoletti, Roberto [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); Orsenigo, Elena [San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Chiari, Damiano; Staudacher, Carlo [San Raffaele Vita-Salute University, Milan (Italy); San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Albarello, Luca [San Raffaele Scientific Institute, Pathology Unit, Milan (Italy)

    2017-05-15

    To investigate the association between preoperative texture analysis from multidetector computed tomography (MDCT) and overall survival in patients with gastric cancer. Institutional review board approval and informed consent were obtained. Fifty-six patients with biopsy-proved gastric cancer were examined by MDCT and treated with surgery. Image features from texture analysis were quantified, with and without filters for fine to coarse textures. The association with survival time was assessed using Kaplan-Meier and Cox analysis. The following parameters were significantly associated with a negative prognosis, according to different thresholds: energy [no filter] - Logarithm of relative risk (Log RR): 3.25; p = 0.046; entropy [no filter] (Log RR: 5.96; p = 0.002); entropy [filter 1.5] (Log RR: 3.54; p = 0.027); maximum Hounsfield unit value [filter 1.5] (Log RR: 3.44; p = 0.027); skewness [filter 2] (Log RR: 5.83; p = 0.004); root mean square [filter 1] (Log RR: - 2.66; p = 0.024) and mean absolute deviation [filter 2] (Log RR: - 4.22; p = 0.007). Texture analysis could increase the performance of a multivariate prognostic model for risk stratification in gastric cancer. Further evaluations are warranted to clarify the clinical role of texture analysis from MDCT. (orig.)

  5. Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

    Science.gov (United States)

    Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae

    2010-03-01

    Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.

  6. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    International Nuclear Information System (INIS)

    Yeh, Jun Jun; Chen, Solomon Chih-Cheng; Teng, Wen-Bao; Chou, Chun-Hsiung; Hsieh, Shih-Peng; Lee, Tsung-Lung; Wu, Ming-Ting

    2010-01-01

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 ± 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  7. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Jun Jun [Pingtung Christian Hospital, Pingtung (China); Mei-Ho Institute of Technology, Pingtung (China); China Medical University, Taichung (China); Chen, Solomon Chih-Cheng [Pingtung Christian Hospital, Pingtung (China); National Taiwan University, Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, Taipei (China); Teng, Wen-Bao; Chou, Chun-Hsiung; Hsieh, Shih-Peng; Lee, Tsung-Lung [Pingtung Christian Hospital, Pingtung (China); Wu, Ming-Ting [National Yang Ming University, Faculty of Medicine, School of Medicine, Taipei (China); Kaohsiung Veterans General Hospital, Section of Thoracic and Circulation Imaging, Department of Radiology, Kaohsiung (China)

    2010-09-15

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 {+-} 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  8. Multidetector computed tomography findings of mesenteroaxial gastric volvulus combined with torsion of wandering spleen: A case report and literature review

    International Nuclear Information System (INIS)

    Youn, In Kyung; Ku, Young Mi; Lee, Su Lim

    2016-01-01

    Gastric volvulus, defined as an abnormal rotation of stomach, may be idiopathic or secondary to abnormal fixation of intraperitoneal visceral ligaments. Wandering spleen is a movable spleen resulting from absence or underdevelopment of the splenic supporting ligaments that suspend the spleen to its normal position in the left part of the supramesocolic compartment of the abdomen. Wandering spleen increases the risk of splenic torsion. Both gastric volvulus and splenic torsion are potentially life-threatening if not urgently managed with surgery. Prompt and accurate diagnosis based on multidetector computed tomography (MDCT) is crucial to prevent unforeseen complications. Gastric volvulus and coexistent torsion of wandering spleen is a very rare condition. Herein, we described a case of gastric volvulus associated with wandering spleen and intestinal non-rotation in a 15-year-old girl focusing on MDCT findings

  9. Multidetector computed tomography findings of mesenteroaxial gastric volvulus combined with torsion of wandering spleen: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Kyung; Ku, Young Mi; Lee, Su Lim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2016-05-15

    Gastric volvulus, defined as an abnormal rotation of stomach, may be idiopathic or secondary to abnormal fixation of intraperitoneal visceral ligaments. Wandering spleen is a movable spleen resulting from absence or underdevelopment of the splenic supporting ligaments that suspend the spleen to its normal position in the left part of the supramesocolic compartment of the abdomen. Wandering spleen increases the risk of splenic torsion. Both gastric volvulus and splenic torsion are potentially life-threatening if not urgently managed with surgery. Prompt and accurate diagnosis based on multidetector computed tomography (MDCT) is crucial to prevent unforeseen complications. Gastric volvulus and coexistent torsion of wandering spleen is a very rare condition. Herein, we described a case of gastric volvulus associated with wandering spleen and intestinal non-rotation in a 15-year-old girl focusing on MDCT findings.

  10. Bosniak category III cysts are more likely to be malignant than we expected in the era of multidetector computed tomography technology

    Directory of Open Access Journals (Sweden)

    Pal Bata

    2014-01-01

    Full Text Available Background: Complex indeterminate Bosniak category III renal cystic masses are traditionally considered to be malignant in 50%. Our aim was to retrospectively evaluate the attenuation characteristics in multiphase computed tomography (CT and to determinate the incidence of malignancy based on histological findings on all Bosniak category III renal cystic masses investigated in our department between April 3, 2007 and November 21, 2013. Materials and Methods: Quadriphasic multidetector CT images of nineteen patients (mean age: 56.5 ± 16.5 years with radiologically detected Bosniak category III lesions were reviewed retrospectively. All lesions were surgically removed, and the incidence of malignancy, based on pathological results was determined. Results: Calcification was present in four lesions (21%. The mean largest diameter was 48.7 ± 28.8 mm. All lesions were multilobulated and septated. Of the 19 removed lesions, 16 (84% were malignant, and 3 (16% were benign (one inflammatory cyst including a nephrolith, one cystic nephroma and one atypical angiomyolipoma. CT and histological findings of 19 Bosniak III cysts were correlated. Conclusion: Our study demonstrated much higher prevalence of malignancy (84% in radiologically detected Bosniak category III cysts than it has been described before. It may due to the era of modern multidetector CT technology and multiphase protocol.

  11. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  12. Novel prediction model of renal function after nephrectomy from automated renal volumetry with preoperative multidetector computed tomography (MDCT).

    Science.gov (United States)

    Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo

    2015-10-01

    The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p volumetry and clinical indices might yield an important tool for predicting postoperative renal function.

  13. Diagnostic yield of multidetector computed tomography in patients with acute spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Rausch, Vanessa Hanna; Bannas, Peter; Well, Lennart; Regier, Marc; Adam, Gerhard; Henes, Frank Oliver Gerhard [Univ. Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology and Nuclearmedicine; Schoen, Gerhard [Univ. Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Medical Biometry and Epidemiology; Froelich, Andreas [Univ. Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Neuroradiology

    2017-04-15

    To determine the value of multidetector computed tomography (MDCT) in patients with acute spondylodiscitis. For data acquisition, we searched our radiological database for all patients who had undergone magnetic resonance imaging (MRI) for suspected spondylodiscitis between 2007 and 2015 (n = 325). For further analyses, we included all patients (n = 67) who initially underwent MDCT prior to MRI. Overall accuracy, sensitivity, specificity and positive and negative predictive values were calculated for MDCT and, separately, for contrast-enhanced CT (CECT, n = 36) and for non-enhanced CT (NECT, n = 31). MRI together with clinical evaluation served as the standard of reference. Results: In 34 of 43 patients with acute spondylodiscitis on MRI, correct diagnosis was already made by the initial MDCT scan. The specificity and positive predictive value were 100% for MDCT. The sensitivity was 79% and the negative predictive value was 72%. The overall accuracy was 87%. Accuracy was higher for CECT (89%) than for NECT (84%), however without statistical significance (p = 0.55). MDCT detected 90% of paravertebral abscesses (34/38), but only 6% of epidural abscesses (2/36). MDCT has moderate sensitivity, but high specificity for acute spondylodiscitis. Thus, if MDCT is positive for spondylodiscitis, treatment can be started without further delay. However, MRI should be added to both MDCT negative and positive cases to rule out complications such as epidural abscesses that cannot reliably be detected by MDCT. Key Points: Patients with acute spondylodiscitis are often initially suspected of having other differential diagnosis because of nonspecific symptoms. Therefore, MDCT is frequently performed prior to MRI in patients with acute spondylodiscitis. MDCT proved moderate sensitivity but high specificity for the diagnosis of acute spondylodiscitis. Paravertebral abscess is a strong indicator for the presence of spondylodiscitis on MDCT. However, MRI is crucial to rule out epidural

  14. Blunt trauma of bone structures of the chest: Computed tomography vs multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Petrović Kosta

    2013-01-01

    Full Text Available Background/Aim. Computerized tomography (CT, especially multidetector CT (MDCT, has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR. Methods. This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists independently and separately described the findings for 5-mmthick axial CT slices (5 mm CT as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thinslice examination together which was ultimately considered as a real, true finding. Results. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05. Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05 in favor of better display of injury by MDCT examination. Conclusion. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  15. Underdiagnosis of Vertebral Collapse on Routine Multidetector Computed Tomography Scan of the Abdomen

    International Nuclear Information System (INIS)

    Obaid, H.; Husamaldin, Z.; Bhatt, R.

    2008-01-01

    Background: Vertebral fractures are commonly associated with osteoporosis and have significant morbidity and mortality rates. Osteoporotic vertebral fractures are presently considered as a treatable and preventable condition, and early detection is vital for further management. The evaluation of vertebral compression on multidetector computed tomography (MDCT) scans of the abdomen has, to our knowledge, not been reported before. Purpose: To assess the prevalence of vertebral collapse on routine abdominal CT scans, and to evaluate the usefulness of the multiplanar reconstruction (MPR) capability of MDCT scans in accurately identifying vertebral abnormalities such as vertebral collapse, spondylolisthesis, and retrolisthesis. Material and Methods: A retrospective review of 307 MDCT scans of the abdomen was carried out at a university teaching hospital. Identifiable patient information was anonymized for data protection. All images were reviewed on a picture archiving and communications system (PACS) using sagittal MPR and bone window for the assessment of the vertebrae. Data were collected from the Computerized Radiology Information System (CRIS). Results: Vertebral collapse was seen in 42 (13.6%) of the 307 patients undergoing routine MDCT of the abdomen. Multilevel and single-level collapses were seen in 24 and 18 patients, respectively. Spondylolisthesis was identified in 5.5% (n=17), and retrolisthesis was seen in 0.6% (n=2). All patients with vertebral fracture were older than 50 years. Women were more commonly affected than men. Conclusion: A significant number of patients with vertebral collapse were diagnosed using MPR on MDCT routine scans of the abdomen

  16. Impact of Multidetector Computerized Tomography (MDCT) On The General Population

    Energy Technology Data Exchange (ETDEWEB)

    Leite, B.B.; Ribeiro, N.C. [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2009-05-15

    Multidetector computerized tomography (MDCT) appeared in the early 1990s, as a technological evolution of computerized tomography. As one would expect, the evolution continues and, each year, more powerful equipments appear, with new medical applications. However, the general use of this technique has lead to the dramatic increase on the general population irradiation. Special concern is required regarding the most vulnerable groups, like the pediatric population, the pregnant and the young female. Due to a larger awareness of this irradiation risks, some initiatives have been developed, coming from different areas, aiming to maximize the benefit to risk ratio of MDCT. (author)

  17. Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Uren Neal G

    2007-06-01

    Full Text Available Abstract Background Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.

  18. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  19. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Maryam Farghadani

    2016-01-01

    Full Text Available Background: The celiac axis, superior mesenteric artery (SMA, and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9% of the 607 patients had classic arterial anatomy and 219 (36.1% patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA from SMA (9.6%, and the next common variation was the origin of the left hepatic artery (LHA from the left gastric artery (6.9%. Variations in the origin of the common hepatic artery (CHA were seen in 16 (2.6% patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8% patients and from the aorta in 8 (1.3% patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8% patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  20. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    International Nuclear Information System (INIS)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon; Jeong, Yong Yeon

    2015-01-01

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall

  1. Incidence of pulmonary embolism and other chest findings in younger patients using multidetector computed tomography

    International Nuclear Information System (INIS)

    Heredia, Vasco; Ramalho, Miguel; Zapparoli, Mauricio; Semelka, Richard C.

    2010-01-01

    Background: Multidetector computed tomography (MDCT) has become the first-line modality for imaging patients with suspected pulmonary embolism (PE). The disadvantages of MDCT, the use of ionizing radiation and iodinated contrast agents, are a reasonable cause of concern, especially in young patients, and therefore it is critical to understand the likelihood of PE in these patients to evaluate a risk benefit analysis. Purpose: To calculate the incidence of PE and other chest findings on MDCT in a young adult population investigated for PE. Material and Methods: 387 consecutive patients (age 31.5±13.5 years) underwent chest MDCT for clinically suspected PE between January 2004 and August 2006. Incidence of PE and other chest findings were calculated with a confidence interval of 95% using binomial distribution. Results: PE incidence was 5%; negative PE with other chest findings was 60%. In 89% of the patients with other chest findings, these included findings of the pleura and/or lung parenchyma. The main patterns of disease were lung opacification suggesting pneumonia (41%), atelectasis (12.4%), and nodular/mass findings (17.5%). In 34% of the patients, there was no PE and no other findings present. Conclusion: There is a low incidence of PE in young patients imaged for PE with MDCT

  2. Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin; Rim, Se Joong

    2010-01-01

    To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3DVTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography

  3. Computed tomography with multidetectors in the diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Lombo, Bernardo; Carvajal, Codos A; Tafur, Monica; Gomez, Rafael

    2007-01-01

    Coronary angiography that uses multislice spiral computed tomography is a noninvasive technique for the detection of coronary stenosis that has had significant improvements in recent years. The introduction of 16 and 64 row scanners, the development of synchronized scanning electrocardiogram and better reconstruction techniques permit higher spatial and temporal resolution that allows better identification of coronary plaques and significant obstructive coronary lesions. In the next years Multislice spiral computed tomography will continue maturing and it will become a useful non invasive diagnostic imaging tool for the diagnosis of coronary disease and will be integrated to the cardiologic management protocols. Our next review will be focused on the basic and technical aspects of the scanner, diagnostic performance and clinical applications of this new technology

  4. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio; Abe, Takayuki; Ogawa, Kenji

    2013-01-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA -950 ) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950 . The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA -950 . (orig.)

  5. Focal Stenosis in Right Upper Lobe Bronchus in a Recurrently Wheezing Child Sequentially Studied by Multidetector-row Spiral Computed Tomography and Scintigraphy

    Directory of Open Access Journals (Sweden)

    I-Chen Chen

    2009-12-01

    Full Text Available Lower respiratory tract infections associated with wheezing are not uncommon in infants and young children. Among the wheezing-associated disorders, allergic etiologies are more commonly encountered than anatomic anomalies. We present a 3-year-old girl with a sudden attack of asthmatic symptoms including dyspnea, cyanosis and diffuse wheezing. Based on a history of choking, and atelectasis in the right upper lobe detected by chest films, flexible tracheobronchoscopy was arranged and incidentally detected a stenotic orifice in the right upper lobe bronchus. Multidetector-row spiral computed tomography and pulmonary scintigraphy subsequently also disclosed the focal stenosis. She suffered from recurrent wheezing, pneumonia and lung atelectasis during 1 year of follow-up. We emphasize the diagnosis, clinical course and management of focal stenosis in the right upper lobe bronchus.

  6. Effect of Saline Pushing after Contrast Material Injection in Abdominal Multidetector Computed Tomography with the Use of Different Iodine Concentrations

    International Nuclear Information System (INIS)

    Tatsugami, F.; Matsuki, M.; Kani, H.; Tanikake, M.; Miyao, M.; Yoshikawa, S.; Narabayashi, I.

    2006-01-01

    Purpose: To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration. Material and Methods: 120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well. Results: Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different. Conclusion: The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography

  7. Study of the renal segmental arterial anatomy with contrast-enhanced multi-detector computed tomography.

    Science.gov (United States)

    Rocco, Francesco; Cozzi, Luigi Alberto; Cozzi, Gabriele

    2015-07-01

    To use triphasic multi-detector computed tomography (MDCT) to study the renal segmental arterial anatomy and its relationship with the urinary tract to plan nephron-sparing surgery (NSS). One hundred and fifty nine patients underwent abdominal contrast-enhanced MDCT. We evaluated renal arteries and parenchymal vasculature. In 61 patients, the arteries and the urinary tract were represented simultaneously. 86.60% presented a single renal artery; 13.4%, multiple arteries. All single renal arteries divided into anterior and posterior branch before the hilum. The anterior artery branched into a superior, middle, and inferior branch. In 43.14%, the inferior artery arose before the others; in 45.75%, the superior artery arose before the others; in 9.80%, the branches shared a common trunk. In 26.80%, the posterior artery supplies the entire posterior surface; in 73.20%, it ends along the inferior calyx. In 96.73%, the upper pole was vascularized by the anterior superior branch and the posterior artery: the "tuning fork". MDCT showed four vascular segments in 96.73% and five in 3.27%. MDCT showed two avascular areas: the first along the projection of the inferior calyx on the posterior aspect, the second between the branches of the "tuning fork". The arterial phase provides the arterial tree representation; the delayed phase shows arteries and urinary tract simultaneously. MDCT provides a useful representation of the renal anatomy prior to intervascular-intrarenal NSS.

  8. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ozcan, H.N.; Gormez, Aysegul; Oguz, Berna; Haliloglu, Mithat [Hacettepe University School of Medicine, Department of Radiology, Ankara (Turkey); Ozsurekci, Yasemin; Ceyhan, Mehmet [Hacettepe University School of Medicine, Department of Pediatric Infectious Disease, Ankara (Turkey); Karakaya, Jale [Hacettepe University School of Medicine, Department of Biostatistics, Ankara (Turkey); Unal, Sule; Cetin, Mualla [Hacettepe University School of Medicine, Department of Pediatric Hematology, Ankara (Turkey)

    2017-02-15

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising. (orig.)

  9. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography.

    Science.gov (United States)

    Ozcan, H Nursun; Gormez, Ayşegul; Ozsurekci, Yasemin; Karakaya, Jale; Oguz, Berna; Unal, Sule; Cetin, Mualla; Ceyhan, Mehmet; Haliloglu, Mithat

    2017-02-01

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising.

  10. Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Ozcan, H.N.; Gormez, Aysegul; Oguz, Berna; Haliloglu, Mithat; Ozsurekci, Yasemin; Ceyhan, Mehmet; Karakaya, Jale; Unal, Sule; Cetin, Mualla

    2017-01-01

    Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising. (orig.)

  11. Gadolinium Ethoxybenzyl Diethylenetriamine Pentaacetic Acid (Gd-EOB-DTPA)-Enhanced Magnetic Resonance Imaging and Multidetector-Row Computed Tomography for the Diagnosis of Hepatocellular Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ye, Feng; Liu, Jun; Ouyang, Han

    2015-08-01

    The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.

  12. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Catherine Yang

    2013-07-01

    Full Text Available Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications.

  13. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yang, Catherine; Trad, Clovis Simao; Trad, Henrique Simao

    2013-01-01

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  14. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  15. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Knox, M.K. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Cowan, N.C. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Department of Radiology, Churchill Hospital, Oxford OX3 7LJ (United Kingdom)], E-mail: nigel.cowan@nds.ox.ac.uk; Rivers-Bowerman, M.D.; Turney, B.W. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom)

    2008-12-15

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A{sub z}) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive.

  16. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    International Nuclear Information System (INIS)

    Knox, M.K.; Cowan, N.C.; Rivers-Bowerman, M.D.; Turney, B.W.

    2008-01-01

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A z ) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive

  17. Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism

    International Nuclear Information System (INIS)

    Brunot, S.; Corneloup, O.; Latrabe, V.; Montaudon, M.; Laurent, F.

    2005-01-01

    The aim of this study was to evaluate the inter-observer and intra-observer agreement of the diagnosis of sub-segmental acute pulmonary embolism (PE) in an inpatient population explored by 16 slice multi-detector spiral computed tomography (MDCT). Four hundred consecutive inpatients were referred for MDCT for the clinical suspicion of acute PE. One hundred and seventy seven (44.2%) had a known cardio-respiratory disease at the time of examination. Inter-observer and intra-observer agreements for the diagnosis of acute PE and of sub-segmental acute PE were assessed blind and independently by three experienced readers and by kappa statistics. Seventy-five patients were diagnosed as having acute PE findings (19.5%), and clots were located exclusively within sub-segmental arteries in nine patients (12%). When clots were limited to sub-segmental or more distal branches of the pulmonary arteries, kappa values were found to be moderate (0.56) to very good (0.85) for the diagnosis of sub-segmental acute PE, whereas for the diagnosis of acute PE in the whole population, kappa values ranged from 0.84 to 0.97. Intra-observer agreement was found to be perfect (kappa=1). MDCT is a reproducible technique for the diagnosis of sub-segmental acute PE as well as for acute PE. In this inpatient population, sub-segmental acute PE was not a rare event. (orig.)

  18. Multidetector Computed Tomography Arthrography of the Shoulder: Diagnostic Accuracy and Indications

    International Nuclear Information System (INIS)

    De Filippo, M.; Bertellini, A.; Sverzellati, N.; Pogliacomi, F.; Costantino, C.; Vitale, M.; Zappia, M.; Corradi, D.; Garlaschi, G.; Zompatori, M.

    2008-01-01

    Background: The presence of subcutaneous implants, such as permanent defibrillators, is an absolute contraindication to the use of magnetic resonance imaging (MRI). Moreover, MRI is unadvisable in subjects with metallic hardware near the area of study, as artifacts generated by such materials distort image quality. Purpose: To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography arthrography (arthro-MDCT) of the shoulder in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Material and Methods: After intraarticular injection of iodixanol and volumetric acquisition, 70 shoulders in 70 patients (30 females, 40 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI because of absolute contraindications (subcutaneous electronic implants), surgical metal implants, or claustrophobia. In 28 of the 70 patients who had had previous shoulder surgery, the arthro-CT examination was preceded by an MRI on the same day. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In the 42 non-operated patients, the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 87% and 100%. In the 28 operated shoulders, arthro-MDCT had an accuracy of 94% compared with 25% with MRI. Interobserver agreement was almost perfect (κ=0.95) in the evaluation of all types of lesions, both on MDCT and MRI. When arthro-MDCT was compared with MRI in the postoperative patients by a McNemar test, a significant difference (P<0.05) was found between these two techniques. Conclusion: Arthro-MDCT of the shoulder is a safe technique that provides

  19. Multidetector Computed Tomography Arthrography of the Shoulder: Diagnostic Accuracy and Indications

    Energy Technology Data Exchange (ETDEWEB)

    De Filippo, M.; Bertellini, A.; Sverzellati, N.; Pogliacomi, F.; Costantino, C.; Vitale, M.; Zappia, M.; Corradi, D.; Garlaschi, G.; Zompatori, M. (Dept. of Clinical Sciences, Section of Radiological Sciences, Univ. of Parma, Parma Hospital, Parma (Italy))

    2008-06-15

    Background: The presence of subcutaneous implants, such as permanent defibrillators, is an absolute contraindication to the use of magnetic resonance imaging (MRI). Moreover, MRI is unadvisable in subjects with metallic hardware near the area of study, as artifacts generated by such materials distort image quality. Purpose: To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography arthrography (arthro-MDCT) of the shoulder in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Material and Methods: After intraarticular injection of iodixanol and volumetric acquisition, 70 shoulders in 70 patients (30 females, 40 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI because of absolute contraindications (subcutaneous electronic implants), surgical metal implants, or claustrophobia. In 28 of the 70 patients who had had previous shoulder surgery, the arthro-CT examination was preceded by an MRI on the same day. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In the 42 non-operated patients, the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 87% and 100%. In the 28 operated shoulders, arthro-MDCT had an accuracy of 94% compared with 25% with MRI. Interobserver agreement was almost perfect (kappa=0.95) in the evaluation of all types of lesions, both on MDCT and MRI. When arthro-MDCT was compared with MRI in the postoperative patients by a McNemar test, a significant difference (P<0.05) was found between these two techniques. Conclusion: Arthro-MDCT of the shoulder is a safe technique that provides

  20. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  1. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  2. Anatomical variants of celiac trunk, hepatic and renal arteries in a population of developing country using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Arifuzzaman, M.; Naqvi, S.S.N.; Rasool, M.; Hussain, M.

    2017-01-01

    Background: Multidetector Computed Tomography (MDCT)s has become a major part in evaluation of hepatic and renal tumours. With improvements in MDCT, CT angiography has also improved and normal anatomy and its variants in patients undergoing operative or interventional procedures can be effectively studied. The purpose of this study was to evaluate the frequency of anatomical variation of celiac trunk, hepatic and renal arterial systems in patients undergoing multidetector CT (MDCT) angiography of the abdominal aorta. Methods: A descriptive, retrospective cross-sectional study was carried out on CT angiographies performed during the months of October till December 2015. Hepatic and renal arteries and celiac trunk were studied and normal and anatomical variations were noted. All patients with abnormalities affecting the vessels or a history of any vascular abnormality were excluded from the study. Results: Out of total 110 patients, 69.1% had normal and 30.9% had variant hepatic artery with Michel Type IV being the most common variant whereas 88.2% had normal celiac trunk and 8.2% had gastrosplenic trunk variant. Variation in renal arterial system was observed in 15.5% of the patients with two renal arteries on right and two on left being the most common type. Multiple variants were identified in 11.8% of the patients. Conclusion: The type and knowledge of anatomy is of prime importance for an optimum preoperative planning in surgical or radiological procedure. MDCT allows minimally invasive assessment of arterial anatomy with high quality 3D reconstruction images. (author)

  3. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  4. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Chou [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tsai, Shih-Hung [Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Chang, Wei-Kuo [Division of Gasteroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Liu, Chang-Hsien [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tung, Ho-Jui [Department of Healthcare Administration, Asia University, Taichung, Taiwan (China); Hsieh, Chung-Bao [Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Huang, Guo-Shu; Hsu, Hsian-He [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Yu, Chih-Yung, E-mail: chougo2002@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China)

    2011-11-15

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  5. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chang, Wei-Chou; Tsai, Shih-Hung; Chang, Wei-Kuo; Liu, Chang-Hsien; Tung, Ho-Jui; Hsieh, Chung-Bao; Huang, Guo-Shu; Hsu, Hsian-He; Yu, Chih-Yung

    2011-01-01

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  6. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    International Nuclear Information System (INIS)

    Lessick, Jonathan; Abadi, Sobhi; Agmon, Yoram; Keidar, Zohar; Carasso, Shemi; Aronson, Doron; Ghersin, Eduard; Rispler, Shmuel; Sebbag, Anat; Israel, Ora; Hammerman, Haim; Roguin, Ariel

    2012-01-01

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition

  7. Multidetector computed tomographic pulmonary angiography in patients with a high clinical probability of pulmonary embolism.

    Science.gov (United States)

    Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D

    2016-01-01

    ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely

  8. Assessment of myocardial viability using multidetector computed tomography in patients with reperfused acute myocardial infarction

    International Nuclear Information System (INIS)

    Kim, T.; Choi, B.J.; Kang, D.K.; Sun, J.S.

    2012-01-01

    Aim: To assess the prognostic value of 64-section multidetector computed tomography (MDCT) to predict follow-up myocardial dysfunction and functional recovery after reperfusion therapy in patients with acute myocardial infarction (MI) as defined by echocardiography. Materials and methods: After reperfusion therapy for acute MI, 71 patients underwent two-phase contrast-enhanced MDCT and follow-up echocardiography. MDCT findings were compared with echocardiographic findings using kappa statistics. The areas under the receiver operating characteristic curves (AUCs) and the odds ratios (ORs) of early perfusion defects (EPD), delayed enhancement (DE), and residual perfusion defects (RPD) for predicting follow-up myocardial dysfunction and functional recovery were calculated on a segmental basis. Results: The presence of transmural EPD (EPD TM ) or RPD showed good agreement (k = 0.611 and 0.658, respectively) with follow-up myocardial dysfunction, while subendocardial EPD (EPD sub ) or subendocardial DE (DE sub ) showed fair agreement with follow-up myocardial dysfunction (k = 0.235 and 0.234, respectively). The AUC of RPD (0.796) was superior (p TM (0.761) and DE TM (0.771). The presence of EPD TM , DE TM , and RPD were significant, independent positive predictors of follow-up myocardial dysfunction (OR = 6.4, 1.9, and 9.8, respectively). EPD TM was a significant, independent negative predictor of myocardial functional recovery (OR = 0.13). Conclusion: Abnormal myocardial attenuation on two-phase MDCT after reperfusion therapy may provide promising information regarding myocardial viability in patients with acute MI.

  9. Nasal and skull base anatomy of endoscopic endonasal transsphenoidal surgery with multi-detector computed tomography

    International Nuclear Information System (INIS)

    Hasegawa, Yuzo; Saeki, Naokatsu; Murai, Hisayuki; Horiguchi, Kentaro; Hanazawa, Toyoyuki; Okamoto, Miyoshi; Yanagawa, Noriyuki

    2008-01-01

    The endoscope is a new and highly useful instrument for transphenoidal surgery (TSS), and is generally used because of its minimally invasiveness. In addition, endoscopic transsphenoidal surgey (eTSS) has a potential for more radical tumor removal at the pituitary and the parasellar regions by wider visualization and more powerful illumination. To operate these regions safely, we need to know nasal and skull base anatomy under the endoscope which looks different from images under a microscope. In this paper, we demonstrated nasal and skull base anatomy with multi-detector computed tomography, which was performed in 23 recent patients with pituitary and parasellar legions. In the nasal legion, deviation of nasal septum and deviation of sphenoid ostium are important for endonasal approach of eTSS, and often determine the difficulty of surgery in the nasal cavity. Our study showed that deviation of nasal septum was seen in 26% of patients. Deviation of sphenoid ostium was 5.5±1.5 mm from the midline. The anatomy of sphenoid sinus plays a key role in our determination of the safety of a bony opening of the sella. In addition to sellar, presellar, and concha types, carotid prominence and optic prominence are important to determine the midline orientation. Development of carotid prominence was significantly related to the extent of lateral pneumatization of sphenoid sinus (P=0.0016). Reconstructed 3D-image of sphenoid sinus was very useful in visual understanding skull base anatomy. (author)

  10. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  11. Thoracic Injuries in earthquake-related versus non-earthquake-related trauma patients: differentiation via Multi-detector Computed Tomography

    Directory of Open Access Journals (Sweden)

    Zhi-hui Dong

    2011-01-01

    Full Text Available PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT. METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR = 2.2; p<0.001. Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR=1.2; p<0.05 or flail chest (45/143 vs. 11/66 patients, RR=1.9; p<0.05 were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR= 1.7; p<0.01. Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR= 1.4; p<0.01. Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR=1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001. Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries.

  12. Detection of attenuated plaque in stable angina with 64-multidetector computed tomography: a comparison with intravascular ultrasound.

    Science.gov (United States)

    Jinzaki, Masahiro; Okabe, Teruo; Endo, Ayaka; Kawamura, Akio; Koga, Seiko; Yamada, Minoru; Fukuda, Keiichi; Kuribayashi, Sachio

    2012-01-01

    To clarify multidetector computed tomography (MDCT) findings of attenuated plaque detected by intravascular ultrasound (IVUS). One hundred and fifty-four patients with stable angina underwent MDCT before IVUS. The attenuated plaque was identified in the targeted artery with IVUS, and the same artery was analyzed with MDCT for the presence of a high density area (HDA) >130 Hounsfield units (HU), and a low density area (LDA) HDA in attenuated plaque was compared with that in calcified plaque. Ten attenuated plaques and 15 calcified plaques were identified in 9 of 154 patients (males=9, 66.2 ± 9.5 years). Eight of the 10 attenuated plaques and all 15 calcified plaques were accompanied with a HDA on MDCT. The HDA ranged from 174 to 667 HU (mean 389.0 ± 148.3 HU) in the 8 attenuated plaques, and from 545 to 1,205 HU (mean 920.9 ± 215.9 HU) in 15 calcified plaques. There was a significant difference in CT density of the HDA between the attenuated and calcified plaque (PHDA. MDCT has the ability to demonstrate attenuated plaque as the combination of HDA (approximately 400 HU on average) and LDA HDA can be differentiated from calcified plaque by its lower CT density value.

  13. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  14. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L. [Department of Radiology, Ipswich Hospital, Ipswich IP4 5PD (United Kingdom)], E-mail: simon.smith@ipswichhospital.nhs.uk; Hampson, F. [Department of Radiology, Addenbrooke' s Hospital NHS Trust, Cambridge (United Kingdom); Duxbury, M. [Department of Surgery, Royal Infirmary of Edinburgh, Little France, Edinburgh EH16 4SU (United Kingdom); Rae, D.M.; Sinclair, M.T. [Department of Pancreaticobiliary surgery, Ipswich Hospital, Ipswich IP4 5PD (United Kingdom)

    2008-08-15

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications.

  15. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  16. Evaluation of secondary spontaneous pneumothorax with multidetector CT

    International Nuclear Information System (INIS)

    Hilliard, N.J.; Marciniak, S.J.; Babar, J.L.; Balan, A.

    2013-01-01

    The purpose of this article is to review the underlying causes of secondary pneumothoraces as observed on multidetector computed tomography (MDCT). Using examples from our institutional experience, we shall illustrate important diagnostic features to indicate the underlying lung disease. Understanding the varied range of conditions is important for accurate diagnosis and facilitation of patient management

  17. True tracheal bronchus: Classification and anatomical relationship on multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Kim, Young Tong; Jou, Sung Shick; Lee, Woong Hee

    2017-01-01

    To propose the imaging classification of true tracheal bronchus (TTB) on multi-detector computed tomography (MDCT), and to evaluate its anatomical relationship with surrounding structures. This study included 44 patients who were diagnosed with TTB on MDCT for 6 years. We classified TTB into five types, based on the existence of the right upper lobe bronchus originating from the right main bronchus and the number of segmental bronchi of TTB. We analyzed the site of origin and the running direction of TTB based on its anatomical relationship with surrounding structures and some ancillary findings. The imaging classification of TTB included Type I (47.7%), Type II (13.6%), Type III (11.4%), Type IV (25.0%), and Type V (2.0%). According to the site of origin of TTB, below the aortic arch (52.3%) and at the level of the aortic arch (43.1%) were the two main sites of origin, whereas the frequency of the site of origin above the azygos arch, at the level of the azygos arch, and below the azygos arch was 27.3%, 38.6%, and 34.1%, respectively. Considering both aortic and azygos arches, below the aortic arch and below the azygos arch were the most common sites of origin (27.3%). With respect to the running direction of TTB, in all cases, TTB passed below the azygos arch to the right upper lobe. There was no statistically significant (p > 0.05) difference in age or sex between types of TTB. Ancillary findings included tracheal stenosis (n = 2), narrowing of the right main bronchus (n = 2), luminal narrowing of TTB and bronchiectasis at the distal portion (n = 1), and a highly located azygos arch above the aortic arch (n = 2). The proposed imaging classification of TTB and its anatomical relationship with surrounding structures will improve our understanding of various imaging features and embryological development of TTB. Radiologists should pay careful attention to evaluation of the airway including the trachea on thoracic imaging

  18. True tracheal bronchus: Classification and anatomical relationship on multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong; Kim, Young Tong; Jou, Sung Shick; Lee, Woong Hee [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan (Korea, Republic of)

    2017-04-15

    To propose the imaging classification of true tracheal bronchus (TTB) on multi-detector computed tomography (MDCT), and to evaluate its anatomical relationship with surrounding structures. This study included 44 patients who were diagnosed with TTB on MDCT for 6 years. We classified TTB into five types, based on the existence of the right upper lobe bronchus originating from the right main bronchus and the number of segmental bronchi of TTB. We analyzed the site of origin and the running direction of TTB based on its anatomical relationship with surrounding structures and some ancillary findings. The imaging classification of TTB included Type I (47.7%), Type II (13.6%), Type III (11.4%), Type IV (25.0%), and Type V (2.0%). According to the site of origin of TTB, below the aortic arch (52.3%) and at the level of the aortic arch (43.1%) were the two main sites of origin, whereas the frequency of the site of origin above the azygos arch, at the level of the azygos arch, and below the azygos arch was 27.3%, 38.6%, and 34.1%, respectively. Considering both aortic and azygos arches, below the aortic arch and below the azygos arch were the most common sites of origin (27.3%). With respect to the running direction of TTB, in all cases, TTB passed below the azygos arch to the right upper lobe. There was no statistically significant (p > 0.05) difference in age or sex between types of TTB. Ancillary findings included tracheal stenosis (n = 2), narrowing of the right main bronchus (n = 2), luminal narrowing of TTB and bronchiectasis at the distal portion (n = 1), and a highly located azygos arch above the aortic arch (n = 2). The proposed imaging classification of TTB and its anatomical relationship with surrounding structures will improve our understanding of various imaging features and embryological development of TTB. Radiologists should pay careful attention to evaluation of the airway including the trachea on thoracic imaging.

  19. Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    International Nuclear Information System (INIS)

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Zhang, Di; Kim, Hyun J.; Cody, Dianna D.

    2010-01-01

    Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI 100,air ); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI w ) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI 100,air values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI 100,air ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI w for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

  20. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  1. Facture of the Pars Interarticularis with or without Spondylolisthesis in an Adult Population in a Developing Country: Evaluation by Multidetector Computed Tomography

    Science.gov (United States)

    Khan, Sohail Ahmed; Sattar, Amjad; Khanzada, Usman; Adil, Syed Omair; Hussain, Munawar

    2017-01-01

    Study Design Descriptive cross-sectional study. Purpose To determine the prevalence of lumbar spondylolysis and spondylolisthesis in a general adult population unrelated to lower back pain as evaluated by multidetector computed tomography. Overview of Literature There is a significant paucity of information related to the prevalence of spondylolysis and spondylolisthesis and its degenerative changes in a general adult population unrelated to lower back pain in developing countries. Methods A retrospective study was conducted on abdominopelvic computed tomography (CT) scans performed between January 1st 2015 and December 31st 2015 for various clinical indications. Patients with lower back pain, with a history of trauma or road traffic accident, or referred from orthopedic or neurosurgery departments were excluded to avoid any bias. CT scans were reviewed in axial, sagittal, and coronal planes using bone window settings for evaluating spondylolysis and spondylolisthesis. Results Of 4,348 patients recruited, spondylolysis and spondylolisthesis were identified in 266 (6.1%) and 142 (3.3%) patients, respectively. Age was significantly higher in both spondylolysis and spondylolisthesis patients than in those without spondylolysis and spondylolisthesis (47.19±15.45 vs. 42.5±15.96, pspondylolysis. Of patients who were >60 years old, both spondylolysis (p=0.018) and spondylolisthesis (p=0.025) were significantly more prevalent in females. Conclusions The prevalence of pars interarticularis fracture observed higher with gradual increase in the prevalence with advancing age. In particular, preponderance was significantly higher among older females. PMID:28670412

  2. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

    Science.gov (United States)

    Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki

    2013-01-01

    This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; Ppannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

  3. Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Rothfuss, Julia K.; Fenchel, Michael; Stauder, Norbert; Kuettner, Axel; Miller, Stephan; Claussen, Claus D.; Kopp, Andreas F.; Schroeder, Stephen; Burgstahler, Christof; Franow, Andreas; Kuzo, Ronald S.

    2006-01-01

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI. (orig.)

  4. Measurement of spinal canal narrowing, interpedicular widening, and vertebral compression in spinal burst fractures: plain radiographs versus multidetector computed tomography

    International Nuclear Information System (INIS)

    Bensch, Frank V.; Koivikko, Mika P.; Koskinen, Seppo K.; Kiuru, Martti J.

    2009-01-01

    To assess the reliability of measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening in burst fractures in radiography compared with multidetector computed tomography (MDCT). Patients who had confirmed acute vertebral burst fractures over an interval of 34 months underwent both MDCT and radiography. Measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening from MDCT and radiography were compared. The 108 patients (30 female, 78 male, aged 16-79 years, mean 39 years) had 121 burst fractures. Eleven patients had multiple fractures, of which seven were not contiguous. Measurements showed a strong positive correlation between radiography and MDCT (Spearman's rank sum test: spinal canal narrowing k = 0.50-0.82, vertebral compression k = 0.55-0.72, and interpedicular widening k = 0.81-0.91, all P 0.25) and for interpedicular widening in the thoracic spine (k = 0.35, P = 0.115). The average difference in measurements between the modalities was 3 mm or fewer. Radiography demonstrates interpedicular widening, spinal canal narrowing and vertebral compression with acceptable precision, with the exception of those of the cervical spine. (orig.)

  5. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  6. Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

    Science.gov (United States)

    Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R

    2010-06-01

    The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non

  7. Increased epicardial fat volume quantified by 64-multidetector computed tomography is associated with coronary atherosclerosis and totally occlusive lesions

    International Nuclear Information System (INIS)

    Ueno, Koji; Anzai, Toshihisa; Jinzaki, Masahiro

    2009-01-01

    The relationship between the epicardial fat volume measured by 64-slice multidetector computed tomography (MDCT) and the extension and severity of coronary atherosclerosis was investigated. Both MDCT and conventional coronary angiography (CAG) were performed in 71 consecutive patients who presented with effort angina. The volume of epicardial adipose tissue (EAT) was measured by MDCT. The severity of coronary atherosclerosis was assessed by evaluating the extension of coronary plaques in 790 segments using MDCT data, and the percentage diameter stenosis in 995 segments using CAG data. The estimated volume of EAT indexed by body surface area was defined as VEAT. Increased VEAT was associated with advanced age, male sex, degree of metabolic alterations, a history of acute coronary syndrome (ACS) and the presence of total occlusions, and showed positive correlation with the stenosis score r=0.28, P=0.02) and the atheromatosis score (r=0.67, P 3 /m 2 ) to be the strongest independent determinant of the presence of total occlusions odds ratio 4.64. P=0.02). VEAT correlates with the degree of metabolic alterations and coronary atheromatosis. Excessive accumulation of EAT might contribute to the development of ACS and coronary total occlusions. (author)

  8. Multidetector row computed tomography noninvasively assesses coronary reperfusion after thrombolytic therapy in patients with ST elevation myocardial infarction

    International Nuclear Information System (INIS)

    Shin, Dong-Il; Won, Yoo-Dong; Chang, Kiyuk

    2006-01-01

    The study objective was to assess the efficacy of 16-slice multidetector row computed tomography (MDCT) in estimating residual stenosis and successful reperfusion after thrombolysis in patients with ST-elevation myocardial infarction (STEMI). A total of 31 patients with STEMI underwent MDCT scanning within 6 h (mean 4.6±1.1) after thrombolysis and the results for detection of significant residual stenosis and distal flow of the infarct-related artery were compared with those from conventional coronary angiography (CCAG) performed within 24 h (mean 12.1±5.6) after the MDCT scan. Successful reperfusion was defined as Thrombolysis In Myocardial Infarction flow 2 or 3 on CCAG and full contrast enhancement of the distal artery landmarks on MDCT. A final analysis was performed using 24 patients (312 segments). MDCT had a positive predictive value of 73.3% and a negative predictive value of 95.1% for detecting significant residual stenosis. It accurately estimated 17 of 18 patients (94.4%) with successful reperfusion and 5 of 6 (83.3%) with failed reperfusion on the basis of comparison with CCAG. MDCT demonstrated high accuracy not only for the detecting residual stenosis, but also for assessing successful reperfusion after thrombolytic therapy in patients with STEMI. (author)

  9. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  10. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  11. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  12. SENSITIVITY OF ENDOSCOPIC ULTRASOUND, MULTIDETECTOR COMPUTER TOMOGRAPHY AND MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY IN THE DIAGNOSIS OF PANCREAS DIVISUM: A TERTIARY CENTER EXPERIENCE

    Science.gov (United States)

    Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.

    2014-01-01

    OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [ppancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370

  13. Is there an indication for computed tomography and magnetic resonance imaging in the evaluation of coronary artery bypass grafts?

    NARCIS (Netherlands)

    Dikkers, R.; van der Zaag-Loonen HJ, [No Value; Willems, T.P.; Post, W.J.; Oudkerk, M.

    2009-01-01

    This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive

  14. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    International Nuclear Information System (INIS)

    Mustonen, A.O.T.; Kiuru, M.J.

    2005-01-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately

  15. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2015-05-01

    Full Text Available Objective The potential of computed tomography angiography (CTA was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours. Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2% based on both clinical grounds and imaging follow-up (stroke group, with statistically significant arterial stenosis and vulnerable plaques on CTA. Intracranial large artery disease was demonstrated in 34% of patients in the stroke group. Partial territorial infarct prevailed (86% while artery-to-artery embolization was the most common stroke mechanism (52%. Conclusion Multidetector CTA was useful for the etiologic work-up of hyperacute ischemic stroke and facilitated the knowledge about the topographic pattern of brain infarct in accordance with its causative mechanism.

  16. Imaging patterns of hepatic steatosis on multidetector CT: Pearls and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Kani, K.K., E-mail: khalatbarik@yahoo.com [Department of Radiology, Body Imaging, University of Washington Medical Center, Seattle, WA (United States); Moshiri, M.; Cuevas, C.; Lee, J.H.; Mitsumori, L.M.; Kolokythas, O. [Department of Radiology, Body Imaging, University of Washington Medical Center, Seattle, WA (United States)

    2012-04-15

    Fatty liver disease is an important cause of chronic liver disease in Western countries. The purpose of this article is to describe and illustrate the diagnostic criteria and various morphological patterns of fatty liver disease on multidetector computed tomography (MDCT) with an emphasis on potential limitations and diagnostic pitfalls.

  17. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  18. Epicardial adipose tissue radiodensity is independently related to coronary atherosclerosis. A multidetector computed tomography study

    International Nuclear Information System (INIS)

    Pracon, R.; Kruk, M.; Kepka, C.

    2011-01-01

    Preliminary research indicates that epicardial adipose tissue (EAT) may display both anti- and proatherosclerotic properties. Because the varying radiodensities of selected human tissues assessed by multidetector computed tomography (MDCT) has been shown to reflect differences in biological characteristics, the present study investigated the hypothesis that the proatherosclerotic properties of EAT may be linked to its radiodensity. The study included 164 consecutive patients (82 females, mean age 58.8±11.1 years) with suspected coronary artery disease (CAD) undergoing MDCT coronary angiography. Coronary atherosclerosis was defined as: CAD (id est (ie), presence of at least 1 coronary stenosis ≥50%) and coronary artery calcium (CAC) determined by Agatston score. EAT radiodensity was assessed by MDCT and averaged -81.00±4.64 HU (Hounsfield unit (HU) scale). Mean CAC score was 96.0±220.0. Patients with CAD (n=36) showed higher EAT radiodensity than patients without CAD (-78.99±4.12 vs. -81.57±4.64 HU, P<0.01). In the multivariable model, only EAT radiodensity and age were independently associated with CAD (odds ratio (OR) 1.15, 95%confidence interval (CI) 1.04-1.28; OR 1.08, 95%CI 1.04-1.12; respectively). EAT radiodensity also correlated with CAC score (r=0.23, P<0.01). EAT radiodensity (P<0.001), age (P<0.001), sex (P=0.03), and past smoking (P<0.01) were independent correlates of CAC in the multivariable linear regression model. Increased EAT radiodensity is independently associated with coronary atherosclerosis, which may reflect the unfavorable, proatherosclerotic metabolic properties of more radiodense epicardial fat. (author)

  19. Estimation of computed tomography dose index in cone beam computed tomography: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald

    2010-05-01

    To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry.

  20. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  1. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    International Nuclear Information System (INIS)

    Tanis, Wilco; Sucha, Dominika; Habets, Jesse; Laufer, Ward; Chamuleau, Steven; Herwerden, Lex.A. van; Symersky, Petr; Budde, Ricardo P.J.

    2015-01-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  2. Denver screening protocol for blunt cerebrovascular injury reduces the use of multi-detector computed tomography angiography.

    Science.gov (United States)

    Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian

    2014-06-01

    Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.

  3. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

    International Nuclear Information System (INIS)

    Adibi, Atoosa; Shahbazi, Ali

    2014-01-01

    Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients

  4. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  5. Comparison of calcium scoring with 4-multidetector computed tomography (4-MDCT) and 64-MDCT: a phantom study.

    Science.gov (United States)

    Serafin, Zbigniew; Rusak, Grazyna; Strześniewski, Piotr; Laskowska, Katarzyna; Lasek, Władysław

    2012-01-01

    To determine differences in coronary artery calcium (CAC) measurement performed with the use of 2 generations of multidetector computed tomography (CT) scanners of the same manufacturer. Agatston Score (AS) and calcium mass (CM) were measured with a 4-row scanner (AS4 and CM4) and a 64-row scanner (AS64 and CM64) using a cardiac phantom with calcium inserts. The results of the AS measurements (mean ± SD) varied significantly between the equipment: 880.6 ± 30.1 (AS4) vs 586.5 ± 24.0 (AS64; P < 0.0001). The AS interscanner variability was 31.6% for the phantom and from 25.5% to 110.1% for particular inserts. Mean ± SD CM values were different as well: 192.8 ± 5.0 mg (CM4) vs 152.4 ± 2.6 mg (CM64; P < 0.0001). Determination of CM with 64-row CT was more accurate than that with an older scanner; the mean relative error was -9.1% and 15.0%, respectively (P < 0.0001). The CM interscanner variability was 23.3% for the phantom and from 19.0% to 122.8% for particular inserts. The interexamination variability ranged from 1.7% (CM64) to 5.6% (AS4). Coronary artery calcium scoring with the 64-row CT scanner is more accurate than with the 4-row device The difference between the results of AS and CM measurements carried out with both scanners is statistically significant.

  6. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  7. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  8. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  9. Computed tomography findings of early abdominal postoperative complications

    International Nuclear Information System (INIS)

    Zissin, R.; Osadchy, A.; Gayer, G.

    2007-01-01

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  10. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  11. Role of whole-body 64-slice multidetector computed tomography in treatment planning for multiple myeloma.

    Science.gov (United States)

    Razek, Ahmed Abdel Khalek Abdel; Ezzat, Amany; Azmy, Emad; Tharwat, Nehal

    2013-08-01

    The authors evaluated the role of whole-body 64-slice multidetector computed tomography (WB-MDCT) in treatment planning for multiple myeloma. This was a prospective study of 28 consecutive patients with multiple myeloma (19 men, nine women; age range, 51-73 years; mean age, 60 years) who underwent WB-MDCT and conventional radiography (CR) of the skeleton. The images were interpreted for the presence of bony lesions, medullary lesions, fractures and extraosseous lesions. We evaluated any changes in treatment planning as a result of WB-MDCT findings. WB-MDCT was superior to CR for detecting bony lesions (p=0.001), especially of the spine (p=0.001) and thoracic cage (p=0.006). WB-MDCT upstaged 14 patients, with a significant difference in staging (p=0.002) between WB-MDCT and CR. Medullary involvement either focal (n=6) or diffuse (n=3) had a positive correlation with the overall score (r=0.790) and stage (r=0.618) of disease. Spine fractures were better detected at WB-MDCT (n=4) than at CR (n=2). Extraosseous soft tissue lesions (n=7) were detected only at WB-MDCT. Findings detected at the WB-MDCT led to changes in the patient's treatment plan in 39% of cases. Upstaging of seven patients (25%) altered the medical treatment plan, and four of 28 (14%) patients required additional radiotherapy (7%) and vertebroplasty (7%). We conclude that WB-MDCT has an impact on treatment planning and prognosis in patients with multiple myeloma, as it has high rate of detecting cortical and medullary bone lesions, spinal fracture and extraosseous lesions. This information may alter treatment planning in multiple myeloma due to disease upstaging and detection of spine fracture and extraosseous spinal lesions.

  12. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  13. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  14. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    Science.gov (United States)

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  15. Right atrial volume calculated by multi-detector computed tomography. Useful predictor of atrial fibrillation recurrence after pulmonary vein catheter ablation

    International Nuclear Information System (INIS)

    Kaneko, Kyouichi; Akutsu, Yasushi; Kodama, Yusuke

    2010-01-01

    We investigated whether right atrial (RA) volume could be used to predict the recurrence of atrial fibrillation (AF) after pulmonary vein catheter ablation (CA). We evaluated 65 patients with paroxysmal AF (mean age, 60+10 years, 81.5% male) and normal volunteers (57±14 years, 41.7% male). Sixty-four-slice multi-detector computed tomography was performed for left atrial (LA) and RA volume estimations before CA. The recurrence of AF was assessed for 6 months after the ablation. Both left and right atrial volumes were larger in the AF patients than the normal volunteers (LA: 99.7+33.2 ml vs. 59.7+17.4 ml; RA: 82.9+35.7 ml vs. 43.9+12 ml; P 100 ml) for predicting the recurrence of AF was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 69.4% in 34 of 49 patients without recurrence. The sensitivity with large RA volumes (>87 ml) was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 75.5% in 37 of 49 patients without recurrence. RA volume is a useful predictor of the recurrence of AF, similar to LA volume. (author)

  16. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  17. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  18. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  19. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  20. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  1. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  2. Influence of gating phase selection on the image quality of coronary arteries in multidetector row computed tomography

    International Nuclear Information System (INIS)

    Laskowska, K.; Marzec, M.; Serafin, Z.; Nawrocka, E.; Lasek, W.; WWisniewska-Szmyt, J.; Kubica, J.

    2005-01-01

    Motion artifacts caused by cardiac movement disturb the imaging of coronary arteries with multidetector-row spiral computed tomography. The aim of this study was to determine the phase of the heart rate which provides the best quality of coronary artery imaging in retrospective ECG-gated CT. Although 75% is usually the best reconstruction phase, the optimal phase should be established individually for the patient, artery, segment, and type of tomograph for the best imaging quality. Forty-five cardiac CT angiograms of 26 patients were retrospectively evaluated. The examinations were performed with a 4-detector-row tomograph. ECG-gated retrospective reconstructions were relatively delayed at 0%, 12.5%, 25%, 37.5%, 50%, 62.5%, 75%, and 87.5% of the cardiac cycle. Selected coronary arteries of the highest diagnostic quality were estimated in the eight phases of the cardiac cycle. Only arteries of very high image quality were selected for analysis: left coronary artery trunks (44 cases, incl. 37 stented), anterior interventricular branches (36, incl. 3 stented), circumflex branches (16), right coronary rtery branches (23), and posterior interventricular branches (4). The reconstruction phase had a statistically significant impact on the quality of imaging (p < 0.0003). Depending on the case, optimal imaging was noted in various phases, except in the 12.5 % phase. The 75% phase appeared to be the best of all those examined (p < 0.05), both in the group of arteries without stents (p < 0.0006) and in those stented (p < 0.05). In some cases of repeated examinations the best phases differed within the same patient. (author)

  3. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  4. Volumetric analysis of coronary plaque characterization in patients with metabolic syndrome using 64-slice multi-detector computed tomography

    International Nuclear Information System (INIS)

    Arai, Kosuke; Ishii, Hideki; Amano, Tetasuya

    2010-01-01

    Metabolic syndrome (MetS) is associated with adverse cardiovascular events and mortality, where acute coronary syndrome significantly impacts on mortality and morbidity. In contrast, evidences have accumulated that the lipid-rich plaque might play a critical role in acute coronary syndrome. The study population consisted of 94 patients with suspected angina pectoris who underwent multi-detector computed tomography (MDCT). Of those, we identified 41 with MetS. In MDCT analysis, low-density plaque volume (LDPV) (42±28 vs 24±18 mm 3 , P=0.0003), moderate-density plaque volume (105±41 vs 82±33 mm(3), P=0.003), total plaque volume (164±70 vs 118±59 mm 3 ), P=0.0008) and %LDPV (24.2±10.0 vs 18.3±7.1%, P=0.01) were significantly increased in the MetS group compared to the non-MetS group. Multivariate linear regression analysis after adjusting for confounding variables revealed that MetS was significantly correlated with an increase in %LDPV (β=0.48, P=0.0001). Multivariate logistic regression analysis for lipid-rich plaque after adjusting for confounding variables indicated that MetS was significantly associated with lipid-rich plaque (odds ratio: 5.99, 95% confidence intervals: 1.94-18.6, P=0.002). Patients with MetS were strongly related to having a lipid-rich composition in their coronary plaque, as detected by MDCT. (author)

  5. Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

    International Nuclear Information System (INIS)

    Baumann, Clemens; Fuchs, Heiko; Westphalen, Kerstin; Hierholzer, Johannes

    2008-01-01

    The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190 o ; 1.5 o per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's κ-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, κ = 0.008) to intermediate (trace of vertebroplasty canula; κ = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with κ values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of κ = 0.768 ('good correlation') and a maximum of κ = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

  6. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Muhammed Bora Demircelik

    2014-06-01

    Full Text Available OBJECTIVE:The aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease.METHODS:The study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing <50% in diameter, Group 2; and obstructive atherosclerosis (luminal narrowing ≥50% in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium. Epicardial adipose tissue thickness (mm was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses.RESULTS:The average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm.CONCLUSION:We showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases.

  7. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  8. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    International Nuclear Information System (INIS)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan; Bozkurt, Alper; Akin, Kayihan; Yilmaz, Omer Caglar

    2014-01-01

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  9. Accurate determination of high-risk coronary lesion type by multidetector cardiac computed tomography.

    Science.gov (United States)

    Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P

    2008-07-01

    Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.

  10. [Sigmoid endometriosis: a diagnostic dilemma on multidetector CT].

    Science.gov (United States)

    Telegrafo, Michele; Lorusso, Valentina; Rubini, Giuseppe; Rella, Leonarda; Pezzolla, Angela; Stabile Ianora, Amato Antonio; Moschetta, Marco

    2013-01-01

    Intestinal endometriosis represents a common condition that occurs particularly in women of reproductive age. The gastrointestinal tract is the third most common localization of endometriosis, after the ovaries and the peritoneum, and recto-sigmoid tract is involved in 70% of cases. Recto-sigmoid endometriosis has to be differentiated from other diseases of large bowel, especially in patients without a history of endometriosis. We report a case of sigmoid endometriosis which represented a diagnostic dilemma on multidetector computed tomography.

  11. Imaging of peripheral arteries by 16-slice computed tomography angiography: a valuable tool

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2007-01-01

    To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral vascular disease. Thirty three patients underwent multislice computed tomography angiography (MSCTA) of the upper or the lower limb on multislice (16-slice) CT scanner between November 2004 and July 2005 in the Department of Radiology, National Organ Transplant Center, Tripoli, Libya. The findings were retrospectively compared with the surgical outcome in cases of trauma with suspected arterial injuries; or color Doppler correlation was obtained, for patients of peripheral vascular disease. Multislice computed tomography angiography allows a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In 23 cases of peripheral vascular diseases, MSCTA adequately demonstrated the presence of any stenosis or occlusion, its degree and extent, the presence of collaterals and distal reformation if any; the presence of plaques. Our experience of computed tomography angiography with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries; and as a useful screening modality in cases of peripheral vascular disease for diagnosis and for grading. (author)

  12. Dataset of calcified plaque condition in the stenotic coronary artery lesion obtained using multidetector computed tomography to indicate the addition of rotational atherectomy during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Yasushi Akutsu

    2016-06-01

    Full Text Available Our data shows the regional coronary artery calcium scores (lesion CAC on multidetector computed tomography (MDCT and the cross-section imaging on MDCT angiography (CTA in the target lesion of the patients with stable angina pectoris who were scheduled for percutaneous coronary intervention (PCI. CAC and CTA data were measured using a 128-slice scanner (Somatom Definition AS+; Siemens Medical Solutions, Forchheim, Germany before PCI. CAC was measured in a non-contrast-enhanced scan and was quantified using the Calcium Score module of SYNAPSE VINCENT software (Fujifilm Co. Tokyo, Japan and expressed in Agatston units. CTA were then continued with a contrast-enhanced ECG gating to measure the severity of the calcified plaque condition. We present that both CAC and CTA data are used as a benchmark to consider the addition of rotational atherectomy during PCI to severely calcified plaque lesions.

  13. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  14. Active extravasation of contrast within the hemorrhage (spot sign: a multidetector computed tomography finding that predicts growth and a worse prognosis in non-traumatic intracerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Marcos Rosa Junior

    2013-10-01

    Full Text Available Intracerebral hemorrhage (ICH causes high rates of disability and neurological sequelae Objective To evaluate spot signs as predictors of expansion and worse prognosis in non-traumatic ICH in a Brazilian cohort. Method We used multidetector computed tomography angiography to study 65 consecutive patients (40 men, 61.5%, with ages varying from 33 to 89 years (median age 55 years. Clinical and imaging findings were correlated with the findings based on the initial imaging. Results Of the individuals who presented a spot sign, 73.7% died (in-hospital mortality, whereas in the absence of a spot sign the mortality rate was 43.0%. Although expansion of ICH was detected in 75% of the patients with a spot sign, expansion was observed in only 9.0% of the patients who did not present a spot sign. Conclusions The spot sign strongly predicted expansion in non-traumatic ICH and an increased risk of in-hospital mortality.

  15. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    Tokue, Hiroyuki; Tokue, Azusa; Tsushima, Yoshito

    2012-01-01

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  16. Cost-Effectiveness Analysis (CEA) of Intravenous Urography (IVU) and Unenhanced Multidetector Computed Tomography (MDCT) for Initial Investigation of Suspected Acute Ureterolithiasis

    International Nuclear Information System (INIS)

    Eikefjord, E.; Askildsen, J.E.; Roervik, J.

    2008-01-01

    Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective

  17. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    International Nuclear Information System (INIS)

    Knox, Matthew K.; Rivers-Bowerman, Michael D.; Bardgett, Harry P.; Cowan, Nigel C.

    2010-01-01

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  18. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Matthew K. [University of Calgary, Faculty of Medicine, UME Office, Health Sciences Centre, Calgary, Alberta (Canada); Rivers-Bowerman, Michael D. [University of British Columbia, Faculty of Medicine, MD Undergraduate Program, Diamond Health Care Centre, Vancouver, British Columbia (Canada); Bardgett, Harry P. [Bradford Teaching Hospitals, Department of Radiology, Bradford (United Kingdom); Cowan, Nigel C. [The Churchill Hospital, Department of Radiology, Oxford (United Kingdom)

    2010-11-15

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  19. Evaluation of right ventricular function with multidetector computed tomography: comparison with magnetic resonance imaging and analysis of inter- and intraobserver variability

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Mira; Teige, Florian; Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite, Medical School, Berlin, PO Box 10098 (Germany)

    2009-02-15

    This study was performed to prospectively compare multidetector computed tomography (MDCT) with 16 simultaneous sections and magnetic resonance imaging (MRI) for the assessment of global right ventricular function in 50 patients. MDCT using a semiautomatic analysis tool showed good correlation with MRI for end-diastolic volume (EDV, r=0.83, p<0.001), end-systolic volume (ESV, r=0.86, p<0.001) and stroke volume (SV, r=0.74, p<0.001), but only a moderate correlation for the ejection fraction (EF, r=0.67, p<0.001). Bland Altman analysis revealed a slight, but insignificant overestimation of EDV (4.0 ml, p= 0.08) and ESV (2.4 ml, p=0.07), and underestimation of EF (0.1%, p=0.92) with MDCT compared with MRI. All limits of agreement between both modalities (EF: {+-}15.7%, EDV: {+-}31.0 ml, ESV: {+-}18.0 ml) were in a moderate but acceptable range. Interobserver variability of MDCT was not significantly different from that of MRI. For MDCT software, the post-processing time was significantly longer (19.6{+-}5.8 min) than for MRI (11.8{+-}2.6 min, p<0.001). Accurate assessment of right ventricular volumes by 16-detector CT is feasible but still rather time-consuming. (orig.)

  20. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    Inoue, Masanori; Hasegawa, Ichiro; Nakano, Keiko; Yamaguchi, Kazuhiro; Kuribayashi, Sachio

    2009-01-01

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV 1.0% ) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV 1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  1. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    International Nuclear Information System (INIS)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung

    2008-01-01

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  2. The value of indicated computed tomography scan of the chest and abdomen in addition to the conventional radiologic work-up for blunt trauma patients.

    NARCIS (Netherlands)

    Deunk, J.; Dekker, H.M.; Brink, M.; Vugt, R. van; Edwards, M.J.R.; Vugt, A.B. van

    2007-01-01

    BACKGROUND: Multidetector computed tomography (CT) is more sensitive and specific in detecting traumatic injuries than conventional radiology is. However, still little is known about the diagnostic value and the therapeutic impact of indicated thoraco-abdominal CT scan when it is performed in

  3. Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Okumoto, Tadayuki; Yamada, Takayuki; Sato, Akihiro

    2009-01-01

    Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. Vascular invasion is considered to be the degree of tumor contiguity to the hepatic arteries and portal vein and was graded by CT. The longitudinal extension was correctly diagnosed in 14 patients (77.8%). Hepatic artery invasion was correctly diagnosed in 17 patients with sensitivity of 100% and specificity of 90%, respectively. Portal vein invasion was correctly diagnosed in 47 of 51 branches with sensitivity and specificity of 92.3% and 90.2%, respectively. Multiplanar reconstructed images contributed to the correct diagnosis for both vascular encasement and longitudinal tumor extension. In conclusion, MDCT is useful in preoperative evaluation of hilar cholangiocarcinoma, especially when combined with multiplanar reconstructed images. (author)

  4. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  5. Volume and dimensions of angiographically normal coronary arteries assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Sørensen, Samuel Kiil; Kühl, Jørgen Tobias; Fuchs, Andreas

    2017-01-01

    BACKGROUND: The objective of this study was to determine normal values for coronary artery volume (CAV) and individual vasculature and segment dimensions. METHODS: We examined 200 healthy volunteers with an Agatston score of 0 and a normal, high quality coronary CTA. Using 320 slice multidetector...... administration and left ventricular mass. The respective contribution of the left and right coronary vascularture is influenced by coronary dominance....

  6. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    International Nuclear Information System (INIS)

    Calisir, C.; Can, C.; Kebapci, M.

    2007-01-01

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis

  7. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Aoki, Takatoshi; Yamagata, Hitoshi; Nogami, Munenobu; Matsumoto, Keiko; Yamashita, Yoshiko; Sugimura, Kazuro

    2013-01-01

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  8. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  9. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  10. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  11. [Study of anatomy of the lateral attachment of the renal fascia in adult with multidetector computed tomography].

    Science.gov (United States)

    Qi, Rui; Zhou, Xianping; Yu, Jianqun; Chen, Weixia; Li, Zhenlin; Zhang, Chunle

    2012-08-01

    The present paper is aimed to observe the lateral attachment of the renal fascia (RF) in vivo with multidetector computed tomography (MDCT) scanning, and to discuss its diagnostic value. 121 healthy adults were adopted into this experiment. All images were obtained with MDCT and double phase enhancement scanning. Then we observed the lateral attachment of RF. In addition, we mad a fresh body specimen as anatomical basis. The study found that above the renal hilar plane (RHP), the anterior renal fascia laterally fused with the peritoneum of the liver on the right and the peritoneum of the spleen on the left,and the posterior renal fascia fused with the subdiaphragmatic fascia. The lateral attachment of the RF at the RHP and the lower renal pole(LRP)is divided into three types. The RF in Type I is about 47.9% (58/121) at the left RHP, while about 33.9% (41/121) at the right RHP. At the LRP of the kidney is about 55.3% (67/121) on the left, and about 42.1% (51/121) on the right. The RF in Type I is about 38.8% (47/121) on the left side at the RHP, about 26.4% (32/121) on the right side. At the LRP, left side about 27.3% (33/121), right side about 13.3%(16/121). The RF in Type III at the RHP is 13.3% (16/121) on the left side, and on the right side is about 39.7% (48/121). At the LRP, it is about 17.4% (21/121) on the left side, and about 44.6% (54/121) on the right side. MDCT can display the lateral attachment of the RF better as well as the outside connection of the retroperitoneal space.

  12. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T.; Scholten, Marcoen F.; Jordaens, Luc J.

    2005-01-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1±2.4 preprocedural versus 18.6±2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2±0.2 versus 1.2±0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1±2.5 mm versus 16.5±2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  13. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Ferencik, Maros; Lisauskas, Jennifer B.; Cury, Ricardo C.; Hoffmann, Udo; Abbara, Suhny; Achenbach, Stephan; Karl, W. Clem; Brady, Thomas J.; Chan, Raymond C.

    2006-01-01

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm 2 and -0.2 ± 2.2 mm 2 (p 2 , respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  15. Visual vs Fully Automatic Histogram-Based Assessment of Idiopathic Pulmonary Fibrosis (IPF) Progression Using Sequential Multidetector Computed Tomography (MDCT)

    Science.gov (United States)

    Colombi, Davide; Dinkel, Julien; Weinheimer, Oliver; Obermayer, Berenike; Buzan, Teodora; Nabers, Diana; Bauer, Claudia; Oltmanns, Ute; Palmowski, Karin; Herth, Felix; Kauczor, Hans Ulrich; Sverzellati, Nicola

    2015-01-01

    Objectives To describe changes over time in extent of idiopathic pulmonary fibrosis (IPF) at multidetector computed tomography (MDCT) assessed by semi-quantitative visual scores (VSs) and fully automatic histogram-based quantitative evaluation and to test the relationship between these two methods of quantification. Methods Forty IPF patients (median age: 70 y, interquartile: 62-75 years; M:F, 33:7) that underwent 2 MDCT at different time points with a median interval of 13 months (interquartile: 10-17 months) were retrospectively evaluated. In-house software YACTA quantified automatically lung density histogram (10th-90th percentile in 5th percentile steps). Longitudinal changes in VSs and in the percentiles of attenuation histogram were obtained in 20 untreated patients and 20 patients treated with pirfenidone. Pearson correlation analysis was used to test the relationship between VSs and selected percentiles. Results In follow-up MDCT, visual overall extent of parenchymal abnormalities (OE) increased in median by 5 %/year (interquartile: 0 %/y; +11 %/y). Substantial difference was found between treated and untreated patients in HU changes of the 40th and of the 80th percentiles of density histogram. Correlation analysis between VSs and selected percentiles showed higher correlation between the changes (Δ) in OE and Δ 40th percentile (r=0.69; phistogram analysis at one year follow-up of IPF patients, whether treated or untreated: Δ 40th percentile might reflect the change in overall extent of lung abnormalities, notably of ground-glass pattern; furthermore Δ 80th percentile might reveal the course of reticular opacities. PMID:26110421

  16. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  17. Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing.

    Science.gov (United States)

    Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria

    2018-01-01

    Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  18. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Sekine, Takako; Kodama, Takahide; Kondo, Takeshi

    2010-01-01

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  19. Diagnostic value of multidetector computed tomography for renal sinus fat invasion in renal cell carcinoma patients

    International Nuclear Information System (INIS)

    Kim, Cherry; Choi, Hyuck Jae; Cho, Kyoung-Sik

    2014-01-01

    Objective: Although renal sinus fat invasion has prognostic significance in patients with renal cell carcinomas (RCCs), there are no previous studies about the value of multidetector computed tomography (MDCT) about this issue in the current literature. Materials and methods: A total of 863 consecutive patients (renal sinus fat invasion in 110 patients (12.7%)) from single institutions with surgically-confirmed renal cell carcinoma who underwent MDCT between 2010 and 2012 were included in this study. The area under the curves (AUCs) of the receiver operating characteristic (ROC) analysis was used to compare diagnostic performance. Reference standard was pathologic examination. Weighted κ statistics were used to measure the level of interobserver agreement. Multivariate logistic regression model was used to find the predictors for renal sinus fat invasion. Image analysis was first performed with axial-only CT images. A second analysis was then performed with both axial and coronal CT images. A qualitative analysis was then conducted by two reviewers who reached consensus regarding tumor size, decreased perfusion, tumor margin, vessel displacement, and lymph node metastasis. The reference standard was pathologic evaluation. Results: The AUCs of the ROC analysis were 0.881 and 0.922 for axial-only images and 0.889 and 0.902 for combined images in both readers. The AUC of tumor size was 0.884, a similar value to that of the reviewers. In multivariate analysis, tumor size, a linear-nodular or nodular type of fat infiltration, and an irregular tumor margin were independent predicting factors for perinephric fat invasion. Conclusion: MDCT shows relatively high diagnostic performance in detecting perinephric fat invasion of RCC but suffers from a relatively low PPV related to low prevalence of renal sinus fat invasion. Applying tumor size alone we could get similar diagnostic performance to those of radiologists. Tumor size, fat infiltration with a nodular appearance, and

  20. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    Directory of Open Access Journals (Sweden)

    Tokue Hiroyuki

    2012-12-01

    Full Text Available Abstract Background We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP using routine 64 multidetector-row computed tomography (MDCT data in order to plan for the implantation of an intra-arterial hepatic port system. Methods A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward. Results The median branching angle was (median ± standard deviation 135 ± 23 (range, 51–174 degrees. The branching was upward in 77 patients (7% and downward in 1,027 patients (93%. The branching was downward with an angle of 120 to150 degrees in most patients (n = 613. The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%. A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. Conclusions The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery.

  1. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  2. Blunt cerebrovascular injury screening with 64-channel multidetector computed tomography: more slices finally cut it.

    Science.gov (United States)

    Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A

    2014-02-01

    Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with

  3. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  4. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Chenggong; Tan, Xiangliang; Li, Caixia; Wu, Yuankui; Hao, Peng; Xiong, Wei; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou, Guangdong (China); Wei, Qi; Feng, Ru; Xu, Jun [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories (China)

    2014-09-18

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  5. Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Thines, Laurent [Lille University Hospital, Department of Neurosurgery, Lille (France); Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Agid, Ronit; Da Costa, Leodante; Terbrugge, Karel G. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Dehdashti, Amir R.; Wallace, M.C.; Tymianski, Michael [Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada)

    2009-08-15

    Extracranial-intracranial (EC/IC) bypass is a useful procedure for the treatment of cerebral vascular insufficiency or complex aneurysms. We explored the role of multidetector computed tomography angiography (MDCTA), instead of digital subtraction angiography (DSA), for the postoperative assessment of EC/IC bypass patency. We retrospectively analyzed a consecutive series of 21 MDCTAs from 17 patients that underwent 25 direct or indirect EC/IC bypass procedures between April 2003 and November 2007. Conventional DSA was available for comparison in 13 cases. MDCTA used a 64-slice MDCT scanner (Aquilion 64, Toshiba). The proximal and distal patencies were analyzed independently on MDCTA and DSA by a neuroradiologist and a neurosurgeon. The bypass was considered patent when the entire donor vessel was opacified without discontinuity from proximal to distal ends and was visibly in contact with the recipient vessel. MDCTA depicted the patency status in every patient. Bypasses were patent in 22 cases, stenosed in one, and occluded in two. DSA always confirmed the results of the MDCTA (sensitivity = 100%, 95% CI = 0.655-1.0; specificity 100%, 95% CI = 0.05-1.0). MDCTA is a non-invasive and accurate exam to assess the postoperative EC/IC bypass patency and is a promising technique in routine follow-up. (orig.)

  6. [In vivo anatomical study of inferior attachment of renal fascia in adult with acute pancreatitis as shown on multidetector computed tomography].

    Science.gov (United States)

    Qi, Rui; Zhou, Xiangping; Yu, Jianqun; Li, Zhenlin

    2014-04-01

    This study aims to explore the inferior adhesion of the renal fascia (RF), and the inferior connectivity of the perirenal spaces (PS) with multidetector computed tomography (MDCT), and to investigate the diagnostic value of CT for showing this anatomy. From May to July 2012, eighty-two patients with acute pancreatitis presented in our hospital were enrolled into this study and underwent contrast-enhanced CT scans. All the image data were used to perform three dimensional reconstruction to show the inferior attachment of RF and the inferior connectivity of PS. The fusion of anterior renal fascia (ARF) and posterior renal fascia (PRF) next to the plane of iliac fossa were found on the left in 71.95% (59/82) cases, and on the right in 75.61% (62/82). In these cases, bilateral perirenal spaces, and anterior and posterior pararenal spaces were not found to be connected with each other. No fusion of ARF and PRF below the level of bilateral kidneys occurred on the left side in 28.05% (23/82) cases and on the right side in 24.39% (20/82). In these patients, the PS extended to the extraperitoneal space of the pelvic cavity and further to the inguinal region, and bilateral anterior and posterior pararenal spaces were not found to be connected with each other. Three-dimensional reconstruction on contrast-enhanced MDCT could be a valuable procedure for depicting inferior attachment of RF, and the inferior connectivity of PS.

  7. First-line sonographic diagnosis of pneumothorax in major trauma: accuracy of e-FAST and comparison with multidetector computed tomography.

    Science.gov (United States)

    Ianniello, Stefania; Di Giacomo, Vincenza; Sessa, Barbara; Miele, Vittorio

    2014-09-01

    Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement). This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16-68 years) admitted to our hospital's emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study. Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6%). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77% (74% in 2011 and 80% in 2012), specificity 99.8%, positive predictive value 98.5%, negative predictive value 97%, accuracy 97.2% (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm). Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.

  8. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  9. The effectiveness of postmortem multidetector computed tomography in the detection of fatal findings related to cause of non-traumatic death in the emergency department

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Higuchi, Takeshi; Shiotani, Motoi; Hirose, Yasuo; Shibuya, Hiroyuki; Hashidate, Hideki; Yamanouchi, Haruo; Funayama, Kazuhisa

    2012-01-01

    To investigate the diagnostic performance of postmortem multidetector computed tomography (PMMDCT) for the detection of fatal findings related to causes of non-traumatic death in the emergency department (ED). 494 consecutive cases of clinically diagnosed non-traumatic death in ED involving PMMDCT were enrolled. The fatal findings were detected on PMMDCT and classified as definite or possible findings. These findings were confirmed by autopsy in 20 cases. The fatal findings were detected in 188 subjects (38.1%) including 122 with definite (24.7%) and 66 with possible finding (13.4%). Definite findings included 21 cases of intracranial vascular lesions, 84 with intra-thoracic haemorrhage, 13 with retroperitoneal haemorrhage and one with oesophagogastric haemorrhage. In three patients who had initially been diagnosed with non-traumatic death, PMMDCT revealed fatal traumatic findings. Two definite findings (two haemopericardiums) and seven possible findings (two intestinal obstructions, one each of multiple liver tumours central pulmonary artery dilatation, pulmonary congestion, peritoneal haematoma, and brain oedema) were confirmed by autopsy. The causes of death were not determined in cases with possible findings without autopsy. PMMDCT is a feasible tool for detecting morphological fatal findings in non-traumatic death in ED. It is important to know the ability and limitation of PMMDCT. (orig.)

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  11. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  12. Technological Evolution on Computed Tomography and Radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2006-05-15

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  13. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho

    2006-01-01

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  14. Association of apolipoprotein b/apolipoprotein A1 ratio and coronary artery stenosis and plaques detected by multi-detector computed tomography in healthy population.

    Science.gov (United States)

    Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu; Lee, Woo Je

    2013-05-01

    Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT.

  15. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    Science.gov (United States)

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  16. Accuracy of multidetector row computed tomography for the diagnosis of acute bowel ischemia in a non-selected study population

    International Nuclear Information System (INIS)

    Wiesner, Walter; Hauser, Andreas; Steinbrich, Wolfgang

    2004-01-01

    The diagnostic accuracy of multidetector row computed tomography for the prospective diagnosis of acute bowel ischemia in the daily clinical routine was analyzed. Two hundred ninety-one consecutive patients with an acute or subacute abdomen, examined by MDCT over a time period of 5 months, were included in the study. All original CT diagnoses made during the daily routine by radiological generalists were compared to the final diagnoses made by using all available medical information from endoscopies, surgical interventions, autopsies and follow-up. Finally, all CT examinations of patients with an initial CT diagnosis or a final diagnosis of bowel ischemia were reread by a radiologist specialized in abdominal imaging in order to analyze the CT findings and the reasons for initially false negative or false positive CT readings. Twenty-four patients out of 291 (8.2%) had acute bowel ischemia. The age of affected patients ranged from 50 to 94 years (mean age: 75.7 years). Eleven patients were male, and 13 female. Reasons for acute bowel ischemia were: arterio-occlusive (n=11), non-occlusive (n=5), strangulation (n=2), over-distension (n=3) and radiation (n=3). The prospective sensitivity, specificity, PPV and NPV of MDCT for the diagnosis of acute bowel ischemia in the daily routine were 79.17, 98.51, 90.48 and 98.15%. MDCT reaches a similarly high sensitivity in diagnosing acute bowel as angiography. Furthermore, it has the advantage of being helpful in most of its clinical differential diagnoses and of being less invasive with the consecutive possibility of being used earlier in the diagnostic process with all the resulting positive effects on the patients prognosis. Therefore, nowadays MDCT should probably be used as the first step imaging modality of choice in patients with suspected acute bowel ischemia. (orig.)

  17. Four-channel multidetector-row computed tomography in the evaluation of facial fractures - optimized parameters for acquisition and multiplanar reformation

    International Nuclear Information System (INIS)

    Omid, P. M.

    2002-08-01

    The first part of this thesis is designed to give the reader a comprehensive survey on the complex basic principles of computed tomography (CT), from the early beginning to the recent development of multidetector-row CT (MD-CT). Attention is focused on imaging of trauma in general and on imaging of facial fractures in particular. The second part of this thesis describes a clinical study performed to optimize acquisition protocols and multiplanar reformation (MPR) algorithms for the evaluation of facial fractures using MD-CT, which has not been yet described in literature. For this study, a cadaver head with artificial blunt facial trauma was examined using a 4-channel MD-CT scanner. The influence of acquisition parameters (collimation: 2x0.5 mm/4x1 mm/4x2.5 mm; tube current: 120 mAs/90 mAs/60 mAs), image reconstruction algorithms (standard vs. ultra-high resolution (UHR) modes; reconstructed slice thicknesses: 0.5 mm/1 mm/3 mm; increment: 0.3 mm/0.6 mm/1.5 mm), and reformation algorithms (slice thicknesses: 0.5 mm/1 mm/3 mm; overlap: 0.5 mm/1 mm/3 mm) on detectability of facial fractures in MPRs with MD-CT was analyzed. Effects of algorithms and parameters on image noise, artifacts and delineation of soft tissues were evaluated. The results of this study reliably demonstrate that fracture detection was significantly higher with thin MPRs (0.5/0.5 mm, 1/0.5 mm, 1/1 mm) (p = 0 .014) acquired with 2x0.5 mm collimation (p = 0 .046), in UHR mode (p .0005) with 120 mAs (p = 0 .025). Inter-observer variability showed very good agreement (κ > = 0 .942). Non-UHR mode, lower mAs and thick MPRs (3/0.5 mm, 3/1 mm, 3/0.5 mm) showed significantly decreased detectability. (author)

  18. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-01-01

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound–color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  19. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  20. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  1. Patent foramen ovale: detection with nongated multidetector CT.

    Science.gov (United States)

    Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques

    2008-10-01

    To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.

  2. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Regier, Marc; Schwarz, Dorothee; Henes, Frank Oliver; Groth, Michael; Begemann, Philipp G.C.; Adam, Gerhard; Kooijman, Hendrik

    2011-01-01

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  3. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    Science.gov (United States)

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

  4. Radiological protection in computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Unenhanced computed tomography in acute renal colic reduces cost outside radiology department

    DEFF Research Database (Denmark)

    Lauritsen, J.; Andersen, J.R.; Nordling, J.

    2008-01-01

    BACKGROUND: Unenhanced multidetector computed tomography (UMDCT) is well established as the procedure of choice for radiologic evaluation of patients with renal colic. The procedure has both clinical and financial consequences for departments of surgery and radiology. However, the financial effect...... outside the radiology department is poorly elucidated. PURPOSE: To evaluate the financial consequences outside of the radiology department, a retrospective study comparing the ward occupation of patients examined with UMDCT to that of intravenous urography (IVU) was performed. MATERIAL AND METHODS......) saved the hospital USD 265,000 every 6 months compared to the use of IVU. CONCLUSION: Use of UMDCT compared to IVU in patients with renal colic leads to cost savings outside the radiology department Udgivelsesdato: 2008/12...

  6. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  7. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  8. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  9. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  10. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  11. Comparison of the multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and extrahepatic cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yata, M.; Suzuki, K.; Furuhashi, N.; Kawakami, K.; Kawai, Y.; Naganawa, S.

    2016-01-01

    Aim: To compare the multidetector-row computed tomography (MDCT) findings of IgG4-related sclerosing cholangitis (IgG4-SC) and extrahepatic cholangiocarcinoma (EH-CCA). Materials and methods: Two radiologists who had no knowledge of the patients' clinical information retrospectively evaluated the CT findings of patients with IgG4-SC (n=33) and EH-CCA (n=39) on a consensus basis. Another radiologist measured the biliary lesions. IgG4-SC was diagnosed using the Japan Biliary Association criteria (2012) or the Mayo Clinic's HISORt criteria. EH-CCA was diagnosed based on surgical findings. Results: Compared with EH-CCA, IgG4-SC exhibited the following findings significantly more frequently: (a) wall thickening alone, (b) concentric wall thickening, (c) smooth inner margins, (d) homogeneous attenuation in the arterial phase, (e) a lesion involving the intrapancreatic bile duct, (f) smooth outer margins, (g) fully visible lumen, (h) a funnel-shaped proximal bile duct, (i) skip lesions, and (j) abnormal pancreatic findings. Conversely, (k) dual-layered attenuation in all phases was significantly more common in EH-CCA. The specificity values of parameters (e–k) were >80%. Regarding dimensions, (l) the biliary lesions were longer in IgG4-SC than in EH-CCA. (m) The diameters of the dilated proximal common bile duct and (n) the dilated proximal intrahepatic bile duct were smaller in IgG4-SC than in EH-CCA. Conclusion: A number of CT findings are useful for differentiating between IgG4-SC and EH-CCA. CT findings (e–k) are particularly useful for this purpose. - Highlights: • Some CT findings are useful for differentiating between IgG4-SC and EH-CCA. • Homogeneous attenuation in all phases was more common in IgG4-SC than in EH-CCA. • Abnormal pancreatic findings showed high sensitivity and specificity values. • Dual-layered attenuation in all phases was more common in EH-CCA than in IgG4-SC.

  12. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  13. Clinical and prognostic significance of bone marrow abnormalities in the appendicular skeleton detected by low-dose whole-body multidetector computed tomography in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Nishida, Y; Matsue, Y; Suehara, Y; Fukumoto, K; Fujisawa, M; Takeuchi, M; Ouchi, E; Matsue, K

    2015-01-01

    Clinical significance of medullary abnormalities in the appendicular skeleton (AS) detected by low-dose whole-body multidetector computed tomography (MDCT) in patients with multiple myeloma (MM) was investigated. A total of 172 patients with monoclonal gammopathy of undetermined significance (MGUS) (n=17), smoldering MM (n=47) and symptomatic MM (n=108) underwent low-dose MDCT. CT values (CTv) of medullary density of AS⩾0 Hounsfield unit (HU) was considered as abnormal. Percentage of medullary abnormalities and the mean CTv of AS in patients with MGUS, smoldering MM and symptomatic MM were 18, 55 and 62% and −44.5 , −20.3 and 11.2 HU, respectively (P<0.001 and P<0.001). Disease progression of MM was independently associated with high CTv on multivariate analysis. In symptomatic MM, the presence of abnormal medullary lesions was associated with increased incidence of high-risk cytogenetic abnormalities (34.4% vs 7.7% P=0.002) and extramedullary disease (10.4% vs 0% P=0.032). It was also an independent poor prognostic predictor (hazard ratio 3.546, P=0.04). This study showed that CTv of AS by MDCT is correlated with disease progression of MM, and the presence of abnormal medullary lesions is a predictor for poor survival

  14. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  16. Incidence of lumbar spondylolysis in the general population in Japan based on multidetector computed tomography scans from two thousand subjects.

    Science.gov (United States)

    Sakai, Toshinori; Sairyo, Koichi; Takao, Shoichiro; Nishitani, Hiromu; Yasui, Natsuo

    2009-10-01

    Epidemiological analysis using CTs. To investigate the true incidence of lumbar spondylolysis in the general population in Japan. Although there have been several reports on the incidence of lumbar spondylolysis, they had some weakness. One of them concerns the subjects investigated, because the incidence of lumbar spondylolysis varies considerably, and some patients are asymptomatic. In addition, most of the past studies used plain radiograph films or skeletal investigation. Therefore, the past reported incidence may not correspond to that of the general population. We reviewed the computed tomography (CT) scans of 2000 subjects (age: 20-92 years) who had undergone abdominal and pelvic CT on a single multidetector CT scanner for reasons unrelated to low back pain. We reviewed them for spondylolysis, spondylolytic spondylolisthesis, and spina bifida occulta (SBO) in the lumbosacral region. The grade (I-IV) of spondylolisthesis was measured using midsagittal reconstructions. Lumbar spondylolysis was found in 117 subjects (5.9%). Their male-female ratio was 2:1. Multiple-level spondylolysis was found in 5 subjects (0.3%). Among these 117 subjects, there were 124 vertebrae with spondylolysis. Of them, 112 (90.3%) corresponded to L5, and 26 (21.0%) had unilateral spondylolysis.SBO was found in 154 subjects. Of them, 25 had spondylolysis (16.2%), whereas, in 1846 subjects without SBO, 92 had spondylolysis (5.0%). The incidence of spondylolysis among the patients with SBO was significantly higher than that in subjects without SBO (Odd ratio was 3.7-fold).Of 124 vertebrae with spondylolysis, 75 (60.5%) showed low-grade (Meyerding grade I or II) spondylolisthesis, and no subject presented high-grade spondylolisthesis. Spondylolisthesis was found in 74.5% of the subjects with bilateral spondylolysis, and in 7.7% of those with unilateral spondylolysis. The incidence of lumbar spondylolysis in the Japanese general population was 5.9% (males: 7.9%, females: 3.9%).

  17. Multidetector CT evaluation of the postoperative pancreas.

    Science.gov (United States)

    Yamauchi, Fernando I; Ortega, Cinthia D; Blasbalg, Roberto; Rocha, Manoel S; Jukemura, José; Cerri, Giovanni G

    2012-01-01

    Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. RSNA, 2012

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  20. Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

    Science.gov (United States)

    Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan

    2009-04-01

    Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.

  1. Three dimensional endo-cardiovascular volume-rendered cine computed tomography of isolated left ventricular apical hypoplasia; A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sun Hwa; Kim, Yang Min; Lee, Hyun Jong [Sejong General Hospital, Bucheon (Korea, Republic of)

    2016-02-15

    We report multidetector computed tomography (MDCT) and cardiac magnetic resonance (CMR) findings of a 34-year-old female with isolated left ventricular apical hypoplasia. The MDCT and CMR scans displayed a spherical left ventricle (LV) with extensive fatty infiltration within the myocardium at the apex, interventricular septum and inferior wall, anteroapical origin of the papillary muscle, right ventricle wrapping around the deficient LV apex, and impaired systolic function. MDCT visualized morphologic and also functional findings of this unique cardiomyopathy.

  2. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  3. Myocardial perfusion 320-row multidetector computed tomography-guided treatment strategy for the clinical management of patients with recent acute-onset chest pain: Design of the CArdiac cT in the treatment of acute CHest pain (CATCH)-2 randomized controlled trial.

    Science.gov (United States)

    Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F

    2016-09-01

    Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Automated detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Cascio, D.; Cheran, S.C.; Chincarini, A.; De Nunzio, G.; Delogu, P.; Fantacci, M.E.; Gargano, G.; Gori, I.; Retico, A.; Masala, G.L.; Preite Martinez, A.; Santoro, M.; Spinelli, C.; Tarantino, T.

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (∝300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan. (orig.)

  5. Research of z-axis geometric dose efficiency in multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Moon Chan

    2006-01-01

    With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for

  6. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    International Nuclear Information System (INIS)

    Serafin, Z.; Lasek, W.; Laskowska, K.

    2008-01-01

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0±13.8 mg and 163.0±4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72±1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  7. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Lasek, W.; Laskowska, K. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2008-11-15

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0+-13.8 mg and 163.0+-4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72+-1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  8. Application of three-dimensional computed tomography in craniofacial clinical practice and research.

    Science.gov (United States)

    Anderson, P J; Yong, R; Surman, T L; Rajion, Z A; Ranjitkar, S

    2014-06-01

    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research. © 2014 Australian Dental Association.

  9. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  10. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have ...

  11. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  12. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  13. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    Science.gov (United States)

    Binder, Ronald K; Leipsic, Jonathon; Wood, David; Moore, Teri; Toggweiler, Stefan; Willson, Alex; Gurvitch, Ronen; Freeman, Melanie; Webb, John G

    2012-04-01

    Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, Pregression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

  14. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Wanner, Matthew R.; Karmazyn, Boaz [Indiana University School of Medicine, Riley Hospital for Children, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Fan, Rong [Indiana University School of Medicine, Riley Hospital for Children, Department of Pathology and Laboratory Medicine, Indianapolis, IN (United States)

    2015-12-15

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  15. Assessment of coronary calcification using calibrated mass score with two different multidetector computed tomography scanners in the Copenhagen General Population Study

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Andreas [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Groen, Jaap M. [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Department of Medical Physics, OLVG, Amsterdam (Netherlands); Arnold, Ben A. [Image Analysis, 1380 Burkesville Road, Columbia, KY (United States); Nikolovski, Sasho [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Knudsen, Andreas D., E-mail: dehlbaek@gmail.com [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Kühl, J. Tobias [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Nordestgaard, Børge G. [Department of Clinical Biochemistry and the Copenhagen General Population Study, Herlev Hospital, University of Copenhagen (Denmark); Greuter, Marcel J.W. [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Kofoed, Klaus F. [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Department of Radiology, The Diagnostic Centre, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2017-03-15

    Objective: Population studies have shown coronary calcium score to improve risk stratification in subjects suspected for cardiovascular disease. The aim of this work was to assess the validity of multidetector computed tomography (MDCT) for measurement of calibrated mass scores (MS) in a phantom study, and to investigate inter-scanner variability for MS and Agaston score (AS) recorded in a population study on two different high-end MDCT scanners. Materials and methods: A calcium phantom was scanned by a first (A) and second (B) generation 320-MDCT. MS was measured for each calcium deposit from repeated measurements in each scanner and compared to known physical phantom mass. Random samples of human subjects from the Copenhagen General Population Study were scanned with scanner A (N = 254) and scanner B (N = 253) where MS and AS distributions of these two groups were compared. Results: The mean total MS of the phantom was 32.9 ± 0.8 mg and 33.1 ± 0.9 mg (p = 0.43) assessed by scanner A and B respectively – the physical calcium mass was 34.0 mg. Correlation between measured MS and physical calcium mass was R{sup 2} = 0.99 in both scanners. In the population study the median total MS was 16.8 mg (interquartile range (IQR): 3.5–81.1) and 15.8 mg (IQR: 3.8–63.4) in scanner A and B (p = 0.88). The corresponding median total AS were 92 (IQR: 23–471) and 89 (IQR: 40–384) (p = 0.64). Conclusion: Calibrated calcium mass score may be assessed with very high accuracy in a calcium phantom by different generations of 320-MDCT scanners. In population studies, it appears acceptable to pool calcium scores acquired on different 320-MDCT scanners.

  16. Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit

    International Nuclear Information System (INIS)

    Greuter, Marcel J.W.; Dorgelo, Joost; Tukker, Wim G.J.; Oudkerk, Matthijs

    2005-01-01

    Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time. (orig.)

  17. Gender disparities in the association between epicardial adipose tissue volume and coronary atherosclerosis: A 3-dimensional cardiac computed tomography imaging study in Japanese subjects

    OpenAIRE

    Dagvasumberel Munkhbaatar; Shimabukuro Michio; Nishiuchi Takeshi; Ueno Junji; Takao Shoichiro; Fukuda Daiju; Hirata Yoichiro; Kurobe Hirotsugu; Soeki Takeshi; Iwase Takashi; Kusunose Kenya; Niki Toshiyuki; Yamaguchi Koji; Taketani Yoshio; Yagi Shusuke

    2012-01-01

    Abstract Background Growing evidence suggests that epicardial adipose tissue (EAT) may contribute to the development of coronary artery disease (CAD). In this study, we explored gender disparities in EAT volume (EATV) and its impact on coronary atherosclerosis. Methods The study population consisted of 90 consecutive subjects (age: 63 ± 12 years; men: 47, women: 43) who underwent 256-slice multi-detector computed tomography (MDCT) coronary angiography. EATV was measured as the sum of cross-se...

  18. Efficacy of double arterial phase dynamic magnetic resonance imaging with the sensitivity encoding technique versus dynamic multidetector-row helical computed tomography for detecting hypervascular hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi; Uemura, Masahiko; Haraikawa, Toyoaki; Hirata, Masaaki; Kikuchi, Keiichi; Mochizuki, Teruhito; Kim, Tonsok

    2009-01-01

    The aim of this study was to evaluate the efficacy of double arterial phase dynamic magnetic resonance imaging (MRI) with the sensitivity encoding technique (SENSE dynamic MRI) for detection of hypervascular hepatocellular carcinoma (HCC) in comparison with double arterial phase dynamic multidetector-row helical computed tomography (dynamic MDCT). A total of 28 patients with 66 hypervascular HCCs underwent both double arterial SENSE dynamic MRI and dynamic MDCT. The diagnosis of HCC was based on surgical resection (n=7), biopsy (n=10), or a combination of CT during arterial portography (CTAP), CT during hepatic arteriography (CTA), and/or the 6-month follow-up CT (n=49). Based on alternative-free response receiving operating characteristic (ROC) analysis, the diagnostic performance for detecting HCC was compared between double arterial phase SENSE dynamic MRI and double arterial phase dynamic MDCT. The mean sensitivity, positive predictive value, and mean A Z values for hypervascular HCCs were 72%, 80%, and 0.79, respectively, for SENSE dynamic MRI and 66%, 92%, and 0.78, respectively, for dynamic MDCT. The mean sensitivity for double arterial phase SENSE dynamic MRI was higher than that for double arterial phase dynamic MDCT, but the difference was not statistically significant. Double arterial phase SENSE dynamic MRI is as valuable as double arterial phase dynamic MDCT for detecting hypervascular HCCs. (author)

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  1. Ultrasound and multidetector computed tomography of mandibular ...

    African Journals Online (AJOL)

    Because of local invasivity and high metastatic potential, preoperative imaging evaluation of mandibular region and tumoral staging is essential along with biopsy sampling. The present manuscript describes the ultrasound and computed tomographic imaging findings of mandibular gland adenocarcinoma in two dogs and ...

  2. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  3. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  4. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  5. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  8. The "Air in the CT X-ray Tube Oil" Artifact-Examples of the Quality Control Images and the Evaluation of Four Potential Clinical Patients' Head Computed Tomography Cases.

    Science.gov (United States)

    Törmänen, Juhani; Rautiainen, Jari; Tahvonen, Pirita; Leinonen, Kimmo; Nieminen, Miika T; Tervonen, Osmo

    We present a newly reposted scanner-based artifact-with 4 potential patients' head computed tomography (CT) cases-the "Air in the CT X-ray Tube Oil" artifact with a 64-slice multidetector CT. This artifact mimics diseases, which cause hypodense findings in CT images. It can be difficult to notice in the clinical patient imaging but can be also very difficult to verify in quality control tests.

  9. Functional imaging of larynx via 256-Slice Multi-Detector Computed Tomography in patients with laryngeal tumors: A faster, better and more reliable pre-therapeutic evaluation

    International Nuclear Information System (INIS)

    Celebi, Irfan; Basak, Muzaffer; Ucgul, Ayhan; Yildirim, Hakan; Oz, Aysel; Vural, Cetin

    2012-01-01

    Objective: To determine the clinical utility of using dynamic maneuvers during imaging of larynx via 256-Slice Multi-Detector Computed Tomography in the pre-therapeutic evaluation of laryngeal tumors. Materials and methods: A total of 27 patients (7 women, 20 men; aged 53–76 years) diagnosed with laryngeal squamous cell carcinoma were evaluated pre-therapeutically via contrast enhanced axial CT scans during consecutive phases of phonation (PP), inspiration (IP) and Valsalva maneuver (VP). Results: In 2 of 5 patients diagnosed with T1a glottic tumor, scans obtained during VP and PP were normal while the CT scans obtained during IP clearly showed a mass. In all patients (27/27) PP provided visualization of the ventricle, on coronal plane images and the pyriform sinus apices, on axial plane images. Involvement of the anterior commissure was best assessable on axial plane IP images (sensitivity 93%, specificity 92%). In cases of stage T1–T3 tumors use of dynamic maneuvers during laryngeal CT imaging showed the location and extension of the tumor better than the single phase CT scans did. We did not find a significant improvement in the pre-therapeutic evaluation in stage T4 tumors. Conclusion: Providing markedly clearer and more detailed evaluation of mucosal surfaces and deep structures of the larynx and mobility of the cords than do conventional scans, use of dynamic laryngeal maneuvers during laryngeal CT imaging seems to be an useful alternative in the pre-therapeutic assessment of laryngeal tumors.

  10. Usefulness of multidetector computed tomography (MDCT) for the initial evaluation of multiple blunt trauma of the trunk

    International Nuclear Information System (INIS)

    Hagiwara, Shuichi; Ogino, Takashi; Isaka, Akira; Takahashi, Yuga; Nameki, Tarou; Kagoshima, Kaie; Yamada, Takurou; Ishihara, Kouichi; Iino, Yuichi

    2008-01-01

    Focused assessment with sonography for trauma (FAST) is useful for detecting hemoperitoneum (HE) in trauma patients in the emergency room (ER), but, patients' condition cannot be evaluated adequately by FAST alone. CT is useful for the diagnosis of multiple trauma, but has certain drawbacks. We evaluated the utility of multidetector computed tomography (MDCT) as the initial tool for proper diagnosis and treatment planning of multiple trauma patients. We retrospectively analyzed 128 cases treated in ER of Gunma University Hospital between April 1, 2005 and December 31, 2006, and they were hospital patients were hospitalized with blunt multiple trauma. We analyzed the sensitivity, specificity, and accuracy of FAST, compiled MDCT finding, lifesaving treatment, and outcome. Eight patients were FAST positive, and 7 of the 8 were scanned by MDCT. There were 120 patients were FAST negative patients, 23 of the 120 were MDCT-negative, despite visceral injury, however 9 of the 120 had visceral injury by MDCT findings. Damage control surgery without MDCT was performed in one case, but the patient died after surgery. Six of the patients in the HE-positive group had really HE. One of the 6 died while a waiting surgery, transcatheter arterial embolization (TAE) was performed in three patients, and one person out of the 3 died. The course of the remaining 2 patients was monitored, and they are alive. A patient in the HE-negative group with bladder rupture required surgery. There were 120 patients in the FAST-negative group. One of the 6 patients in the HE-positive subgroup died while a waiting surgery. One patient required chest and pericardial drainage. TAE was performed in 2 patients, and the remaining 6 were monitored and are alive. There were 23 FAST-negative patients patients who had visceral injury. Five of them required chest drainage, one received TAE, 17 were monitored, and all of the 23 are alive. There were 14 cases of pelvic fracture alone, and all of them were FAST

  11. The Spectrum of Presentations of Cryptogenic Organizing Pneumonia in High Resolution Computed Tomography

    International Nuclear Information System (INIS)

    Mehrian, Payam; Shahnazi, Makhtoom; Dahaj, Ali Ahmadi; Bizhanzadeh, Sorour; Karimi, Mohammad Ali

    2014-01-01

    Various radiologic patterns of cryptogenic organizing pneumonia (COP) in X-rays have been reported for more than 20 years, and later, in computed tomography scans. The aim of the present study was to describe the spectrum of radiologic findings on high resolution computed tomography (HRCT) scans in patients with COP. HRCT scans of 31 sequential patients (mean age: 54.3±11 years; 55% male) with biopsy-proven COP in a tertiary lung center between 2009 and 2012 were reviewed by two experienced pulmonary radiologists with almost perfect interobserver agreement (kappa=0.83). Chest HRCTs from the lung apex to the base were performed using a 16-slice multi-detector CT scanner. The most common HRCT presentation of COP was ground-glass opacity (GGO) in 83.9% of cases, followed by consolidation in 71%. Both findings were mostly asymmetric bilateral and multifocal. Other common findings were the reverse halo (48.4%), parenchymal bands (54.8%) and subpleural bands (32.3%). Pulmonary nodules were found in about one-third of patients and were frequently smaller than 5 mm in diameter. Both GGOs and consolidations were revealed more often in the lower lobes. The main presentations of COP on HRCT include bilateral GGOs and consolidations in the lower lobes together with the reverse halo sign

  12. Perfusion Computed Tomography for the Assessment of Myocardial Viability — a Case Series

    Directory of Open Access Journals (Sweden)

    Morariu Mirabela

    2016-06-01

    Full Text Available Myocardial viability plays an important role in preventing the development of left ventricular remodeling following an acute myocardial infarction. A preserved viability in the infarcted area has been demonstrated to be associated with a lower amplitude of the remodeling process, while the extent of the non-viable myocardium is directly correlated with the amplitude of the remodeling process. A number of methods are currently in use for the quantification of the viable myocardium, and some of them are based on the estimation of myocardial perfusion during pharmacologic stress. 64-slice Multi-detector Computed Tomography (MDCT during vasodilator stress test, associated with CT Coronary Angiography (CCTA has a high diagnostic accuracy in evaluating myocardial perfusion. In this article, we present a sequence of 3 clinical cases that presented with symptoms of myocardial ischemia, who underwent 64-slice MDCT imaging at rest and during adenosine stress test, in order to assess the extent of the hypoperfused myocardial areas. Coronary artery anatomy and the Coronary Calcium Score was assessed for all 3 patients by performing CT Coronary Angiography. The combination of CT Angiography and adenosine stress CT myocardial perfusion imaging can accurately detect atherosclerosic lesions that cause perfusion abnormalities, compared with the combination of invasive angiography and single-photon emission computed tomography (SPECT.

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  14. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Joo, Ijin; Baek, Jee Hyun; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young; Park, Hee Sun

    2014-01-01

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  15. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  16. Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Jung, Yun Hoa [Pusan National Univ. College of Dentistry, Pusan (Korea, Republic of)

    2007-12-15

    To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserve agreements were calculated by using Kappa statistics. The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). This study shows that we can expert good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  17. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  18. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  19. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Chen Tianwu; Yang Zhigang; Dong Zhihui; Li Yuan; Yao Jin; Wang Qiling; Qian Lingling

    2011-01-01

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 ± 0.49 whereas S/N ratios were 5.21 ± 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 ± 24.15 ml/min/ml, 24.06 ± 9.87 HU, 29.42 ± 8.61 s, and 12.45 ± 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  20. Possibilities of differentiation of solitary focal liver lesions by computed tomography perfusion

    Directory of Open Access Journals (Sweden)

    Irmina Sefić Pašić

    2015-08-01

    Full Text Available Aim To evaluate possibilities of computed tomography (CT perfusion in differentiation of solitary focal liver lesions based on their characteristic vascularization through perfusion parameters analysis. Methods Prospective study was conducted on 50 patients in the period 2009-2012. Patients were divided in two groups: benign and malignant lesions. The following CT perfusion parameters were analyzed: blood flow (BF, blood volume (BV, mean transit time (MTT, capillary permeability surface area product (PS, hepatic arterial fraction (HAF, and impulse residual function (IRF. During the study another perfusion parameter was analyzed: hepatic perfusion index (HPI. All patients were examined on Multidetector 64-slice CT machine (GE with application of perfusion protocol for liver with i.v. administration of contrast agent. Results In both groups an increase of vascularization and arterial blood flow was noticed, but there was no significant statistical difference between any of 6 analyzed parameters. Hepatic perfusion index values were increased in all lesions in comparison with normal liver parenchyma. Conclusion Computed tomography perfusion in our study did not allow differentiation of benign and malignant liver lesions based on analysis of functional perfusion parameters. Hepatic perfusion index should be investigated in further studies as a parameter for detection of possible presence of micro-metastases in visually homogeneous liver in cases with no lesions found during standard CT protocol

  1. Combined presence of aortic valve calcification and mitral annular calcification as a marker of the extent and vulnerable characteristics of coronary artery plaque assessed by 64-multidetector computed tomography.

    Science.gov (United States)

    Utsunomiya, Hiroto; Yamamoto, Hideya; Kunita, Eiji; Kitagawa, Toshiro; Ohashi, Norihiko; Oka, Toshiharu; Yamazato, Ryo; Horiguchi, Jun; Kihara, Yasuki

    2010-11-01

    We examined the association of aortic valve calcification (AVC) and mitral annular calcification (MAC) to coronary atherosclerosis using 64-multidetector computed tomography (MDCT). Valvular calcification is considered a manifestation of atherosclerosis. The impact of multiple heart valve calcium deposits on the distribution and characteristics of coronary plaque is unknown. We evaluated 322 patients referred for 64-MDCT, and assessed valvular calcification and the extent of calcified (CAP), mixed (MCAP), and noncalcified coronary atherosclerotic plaque (NCAP) in accordance with the 17-coronary segments model. We assessed the vulnerable characteristics of coronary plaque with positive remodeling, low-density plaque (CT density ≤38 Hounsfield units), and the presence of adjacent spotty calcification. In 49 patients with both AVC and MAC, the segment numbers of CAP and MCAP were larger than in those with a lack of valvular calcification and an isolated AVC (pNCAP. Moreover, it was also related to the presence of coronary plaque with all three vulnerable characteristics (OR 4.87, 95%CI 1.85-12.83, p=0.001). The combined presence of AVC and MAC is highly associated with the presence, extent, and vulnerable characteristics of coronary plaque identified by 64-MDCT. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  3. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  4. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  5. Assessment and diagnosis of acute bowel ischemia with multidetector computed tomography (MDCT)

    International Nuclear Information System (INIS)

    Sojka, B.; Gieszczyk-Paraniak, B.; Gibinska, J.; Konopka, M.

    2008-01-01

    Acute bowel ischemia (ABT) is a life-threatening condition which most often effects elderly patients. It requires an intensive treatment and quick diagnosis. Unfortunately ABI manifested not only by specific but also various nonspecific clinical or laboratory finding. The radiological symptoms of the bowel ischemia are also differentiated and often nonspecific while the specific findings are rather uncommon.That is why the knowledge of the bowel ischemia pathogenesis and possible CT findings is so important for the correct diagnosis. The our paper, we present the radiological findings of the acute bowel ischemia based on the analysis of the patients' abdominal -CT examination. The purpose of our study is to MDCT in patients with acute bowel ischemia. The material of this study consists of four computer tomography examinations - three of those an angio-CT and one abdominal - in patients with acute abdomen symptoms. The result revealed the mesenteric thrombosis in two cases, and mesenteric artery stenosis in one case. In one case, the thrombus was present in the abdominal aorta. In conclusion, we claim that the MDCT should be the modality of choice for the diagnosis of the acute bowel ischemia. (author)

  6. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  7. Head multidetector computed tomography: emergency medicine physicians overestimate the pretest probability and legal risk of significant findings.

    Science.gov (United States)

    Baskerville, Jerry Ray; Herrick, John

    2012-02-01

    This study focuses on clinically assigned prospective estimated pretest probability and pretest perception of legal risk as independent variables in the ordering of multidetector computed tomographic (MDCT) head scans. Our primary aim is to measure the association between pretest probability of a significant finding and pretest perception of legal risk. Secondarily, we measure the percentage of MDCT scans that physicians would not order if there was no legal risk. This study is a prospective, cross-sectional, descriptive analysis of patients 18 years and older for whom emergency medicine physicians ordered a head MDCT. We collected a sample of 138 patients subjected to head MDCT scans. The prevalence of a significant finding in our population was 6%, yet the pretest probability expectation of a significant finding was 33%. The legal risk presumed was even more dramatic at 54%. These data support the hypothesis that physicians presume the legal risk to be significantly higher than the risk of a significant finding. A total of 21% or 15% patients (95% confidence interval, ±5.9%) would not have been subjected to MDCT if there was no legal risk. Physicians overestimated the probability that the computed tomographic scan would yield a significant result and indicated an even greater perceived medicolegal risk if the scan was not obtained. Physician test-ordering behavior is complex, and our study queries pertinent aspects of MDCT testing. The magnification of legal risk vs the pretest probability of a significant finding is demonstrated. Physicians significantly overestimated pretest probability of a significant finding on head MDCT scans and presumed legal risk. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Multidetector Computed Tomography (MDCT in Gastrointestinal Obstruction: One Symptom Myriad Differentials

    Directory of Open Access Journals (Sweden)

    Geetika Sindhwani

    2017-10-01

    Full Text Available Introduction: Computed Tomography (CT is a highly sensitive modality with its multi-planar capabilities, used in evaluation of acute cases of intestinal obstruction. It delineates the level and helps to identify various etiologies of obstruction, where plain radiographs can only suggest signs of obstruction. It has an added advantage of detecting further complications, thus framing appropriate surgical approach. Aim: Our study aims at delineating variable CT spectrum of intestinal obstruction with highlight on atypical presentation. Materials and Methods: Retrospective hospital data based study was conducted in the Radiology Department of Shree Krishna Hospital, Anand, Gujarat, India, between 2014-2017 including 40 patients with mechanical causes of obstruction and excluding patients with non-mechanical causes of obstruction. Statistical analysis was done using percentages and proportions using MedCalc software version 17.6. Results: The age range of patients was from 5 days to 83 years and the maximum number of patients i.e., 7 (17.5% were in the age group of 41-50 years. Radiographic signs related to obstruction like air fluid levels, dilated bowel loops was seen in 26 out of 40 cases (sensitivity 60%. Small bowel obstruction dominated the case list with obstructed hernia as major causative factor. Conclusion: Study highlights the contribution of MDCT in early identification of underlying etiology and complications of obstruction with additional contribution in road mapping and framing appropriate and individualized treatment strategy for patients.

  9. Comparing culprit lesions in ST-segment elevation and non-ST-segment elevation acute coronary syndrome with 64-slice multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W.-C. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: w.c.huang@yahoo.com.tw; Liu, C.-P. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: cpliu@isca.vghks.gov.tw; Wu, M.-T. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: wu.mingting@gmail.com; Mar, G.-Y. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: gymar@isca.vghks.gov.tw; Lin, S.-K. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: skyii89@yahoo.com.tw; Hsiao, S.-H. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: a841120@ms3.hinet.net; Lin, S.-L. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: sllin@isca.vghks.gov.tw; Chiou, K.-R. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: krchiou@isca.vghks.gov.tw

    2010-01-15

    Background: Classifying acute coronary syndrome (ACS) as ST elevation ACS (STE-ACS) or non-ST elevation ACS (NSTE-ACS) is critical for clinical prognosis and therapeutic decision-making. Assessing the differences in composition and configuration of culprit lesions between STE-ACS and NSTE-ACS can clarify their pathophysiologic differences. Objective: This study focused on evaluating the ability of 64-slice multidetector computed tomography (MDCT) to investigate these differences in culprit lesions in patients with STE-ACS and NSTE-ACS. Methods: Of 161 ACS cases admitted, 120 who fit study criteria underwent MDCT and conventional coronary angiography. The following MDCT data were analyzed: calcium volume, Agatston calcium scores, plaque area, plaque burden, remodeling index, and plaque density. Results: The MDCT angiography had a good correlation with conventional coronary angiography regarding the stenotic severity of culprit lesions (r = 0.86, p < 0.001). The STE-ACS culprit lesions (n = 54) had significantly higher luminal area stenosis (78.6 {+-} 21.2% vs. 66.7 {+-} 23.9%, p = 0.006), larger plaque burden (0.91 {+-} 0.10 vs. 0.84 {+-} 0.12, p = 0.007) and remodeling index (1.28 {+-} 0.34 vs. 1.16 {+-} 0.22, p = 0.021) than those with NSTE-ACS (n = 66). The percentage of expanding remodeling index (remodeling index >1.05) was significantly higher in the STE-ACS group (81.5% vs. 63.6%, p = 0.031). The patients with STE-ACS had significantly lower MDCT density of culprit lesions than patients with NSTE-ACS (25.8 {+-} 13.9 HU vs. 43.5 {+-} 19.1 HU, p < 0.001). Conclusions: Sixty-four-slice MDCT can accurately evaluate the stenotic severity and composition of culprit lesions in selected patients with either STE-ACS or NSTE-ACS. Culprit lesions in NSTE-ACS patients had significantly lower luminal area stenosis, plaque burden, remodeling index and higher MDCT density, which possibly reflect differences in the composition of vulnerable culprit plaques and thrombi.

  10. Imaging of pancreatic adenocarcinoma with emphasis on multidetector CT

    International Nuclear Information System (INIS)

    Smith, S.L.; Rajan, P.S.

    2004-01-01

    Pancreatic adenocarcinoma is the fourth most frequent cause of cancer-related death. The incidence is increasing and the overall survival has altered little in recent years. Moreover, patients usually present late with inoperable disease and curative resection by standard pancreatico-duodenectomy (Whipple's procedure) is associated with significant morbidity. It should only be attempted in that small group of patients lacking radiological evidence of advanced disease. Despite the recent advances in body magnetic resonance imaging (MRI) and endoscopic ultrasound (EUS), computed tomography (CT) is the mainstay of staging in most centres and the recent development of multidetector CT machines (MDCT) has raised hope of an improvement in preoperative staging. This review focuses on the CT of pancreatic adenocarcinoma with particular emphasis on examination technique and on those criteria that determine resectability

  11. Imaging of pancreatic adenocarcinoma with emphasis on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L. E-mail: simon.smith@ipsh-tr.anglox.nhs.uk; Rajan, P.S

    2004-01-01

    Pancreatic adenocarcinoma is the fourth most frequent cause of cancer-related death. The incidence is increasing and the overall survival has altered little in recent years. Moreover, patients usually present late with inoperable disease and curative resection by standard pancreatico-duodenectomy (Whipple's procedure) is associated with significant morbidity. It should only be attempted in that small group of patients lacking radiological evidence of advanced disease. Despite the recent advances in body magnetic resonance imaging (MRI) and endoscopic ultrasound (EUS), computed tomography (CT) is the mainstay of staging in most centres and the recent development of multidetector CT machines (MDCT) has raised hope of an improvement in preoperative staging. This review focuses on the CT of pancreatic adenocarcinoma with particular emphasis on examination technique and on those criteria that determine resectability.

  12. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  13. Myocardial perfusion at rest in patients with Diabetes Mellitus Type 1 compared with healthy controls assessed with Multi Detector Computed Tomography

    DEFF Research Database (Denmark)

    Byrne, Christina; Jensen, Tonny; Hjortkjær, Henrik Øder

    2015-01-01

    AIM: Type 1 diabetes mellitus (T1DM) is associated with an increased risk of ischemic heart disease (IHD). The relative contribution of structural and functional abnormalities of the coronary circulation determining clinically manifested IHD remains unknown. The aim of this study was to assess...... artery atherosclerosis were evaluated with 320-multidetector computed tomography angiography in 57 asymptomatic T1DM patients and 114 sex and age matched controls. RESULTS: In both groups median age was 53 years (p5,p95: 42,67) and 59.6% were men. Median duration of diabetes in the T1DM group was 35...

  14. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  15. Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80 kV and iterative reconstruction algorithm using different concentration contrast media.

    Science.gov (United States)

    Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro

    2017-10-01

    Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.

  16. The role of multi-detector CT angiography in surgical planning for congenital cervicothoracic kyphoscoliosis: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun; Choi, Won Gyu; Shin, Ho Dong; Hwang, Byeong Wook; Lee, Sang Jin; Lee, Sang Ho [Busan Wooridul Spine Hospital, Busan (Korea, Republic of)

    2008-01-15

    Surgical correction of a cervicothoracic deformity is difficult with a potential risk of vascular injury. Comprehensive preoperative vascular evaluation is important for safe and successful surgery. The use of multi-detector computed tomography angiography (MDCTA) allows a combined display of vascular and osseous structures of the musculoskeletal system. However, no clinical reports have described the use of MDCTA for surgical planning of anterior cervicothoracic surgery in patients with vascular malformation. The case of a 7-year-old girl with congenital cervicothoracic kyphoscoliosis who underwent preoperative MDCTA evaluation and successful correction is presented in this report.

  17. Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Marielle Ernst

    Full Text Available The hyperdense basilar artery sign (HBAS is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT in acute stroke patients. Since basilar artery occlusion (BAO is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct ratio on the detection of BAO on NECT in patients with suspected BAO.102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio.Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54-95% while specificity was high 91% (95%-CI, 82-96%. The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60-98% and specificity of 84% (95%-CI, 74-90%.In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT.

  18. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography.

    Science.gov (United States)

    Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E

    2016-09-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.

  19. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  1. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  2. Analysis of bone mellow density in adults of domestic local area using multi-detector computed tomography: Focus on correlation about eating habits, lifestyle, physical features and social characteristics

    International Nuclear Information System (INIS)

    Lee, Tae Hui; Kim, Tae Hyung; So, Woon Young; Lim, Hei Gyeom; Lim, Cheong Hwan; Park, Myeong Hwan; Cheon, Myung Ki

    2016-01-01

    This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT(multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference(p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management

  3. Analysis of bone mellow density in adults of domestic local area using multi-detector computed tomography: Focus on correlation about eating habits, lifestyle, physical features and social characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hui [Wonju Medical Center, Wonju (Korea, Republic of); Kim, Tae Hyung; So, Woon Young; Lim, Hei Gyeom [Kangwon National University Graduate School, Wonju (Korea, Republic of); Lim, Cheong Hwan [Hanseo University, Seosan (Korea, Republic of); Park, Myeong Hwan [Daegu Health College, Daegu (Korea, Republic of); Cheon, Myung Ki [Soongsil University, Seoul (Korea, Republic of)

    2016-12-15

    This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT(multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference(p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

  4. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  5. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  6. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    International Nuclear Information System (INIS)

    Caro-Dominguez, Pablo; Manson, David E.; Compton, Gregory; Humpl, Tilman

    2016-01-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  7. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Manson, David E. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Compton, Gregory [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Epworth Hospital, Epworth Medical Imaging, Richmond, VIC (Australia); Humpl, Tilman [University of Toronto, Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON (Canada)

    2016-09-15

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  8. Sixteen-slice multidetector computed tomographic virtual cystoscopy in the evaluation of a patient with suspected bladder tumor and history of bladder carcinoma operation.

    Science.gov (United States)

    Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz

    2009-01-01

    The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.

  9. Preoperative staging of esophageal carcinoma with multidetector CT and virtual endoscopy

    International Nuclear Information System (INIS)

    Onbas, Omer; Eroglu, Atilla; Kantarci, Mecit; Polat, Pinar; Alper, Fatih; Karaoglanoglu, Nurettin; Okur, Adnan

    2006-01-01

    Purpose: The aim of this study was to assess the accuracy of multidetector computed tomography (MDCT), including virtual endoscopy (VE) for detection, precise localization, preoperative evaluation and staging of esophageal cancer (EC) by comparison with surgical and histopathological findings. Materials and methods: Between September 2003 and April 2005, 44 patients with histologically proven EC underwent MDCT and VE. Among 44 patients, the findings were confirmed in 24 at surgery. The accuracy of three-dimensional MDCT for detection, localization, and staging of EC was determined, and compared with surgical finding and histopathology. Results: The overall accuracy of three-dimensional multidetector row CT for detection of EC was 100% (24/24). MDCT staging was correct in 20 patients (83.3%). The T parameter was correctly assessed in 22 (91.7%) cases (understaged in 1 and overstaged in 1). The N parameter was correctly evaluated in 20 (83.4%) patients (understaged in 2 and overstaged in 2). The overall accuracy of VE for the morphologic classification of EC was 81.5%. Conclusions: Three-dimensional MDCT, along with VE is a promising method for preoperative evaluation and staging of EC. Although accuracy in N staging remains low in comparison to PET, it provides a larger amount of diagnostic and staging information

  10. Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Rainer; Froehner, Steffen; Wagner, Matthias; Brunner, Horst; Cherevatyy, Oleg; Christopoulos, Georgios [Herz- und Gefaessklinik GmbH, Department of Radiology, Bad Neustadt an der Saale (Germany); Brunn, Juergen; Gietzen, Frank; Kerber, Sebastian [Herz- und Gefaessklinik GmbH, Department of Cardiology, Bad Neustadt an der Saale (Germany); Fellner, Franz [Oberoesterreichische Landesnervenklinik, Department of Radiology, Linz (Austria)

    2005-06-01

    The objective of this study is to evaluate multidetector CT (MDCT) in detecting and characterizing anomalous coronary arteries. Forty-four patients with anomalies of the coronaries were selected from a total of 1758 individuals examined with ECG-gated 4- and 16-row MDCT including thin MIP, MPR and VRT post-processing. Twenty-eight patients showed origin and course anomalies of the central coronary segments, and in this subgroup 13 were judged as ''malignant'' because of interarterial courses between the aortic root and the pulmonary trunk, either of the right coronary artery (n=11) or the left coronary artery (n=2). Twelve non-hemodynamic anomalies were found, affecting the coronary origins only (n=10) or the peripheral vessels courses (n=2). Four arteriovenous fistulas were present, all of them with complex arterial feeders. Regardless of vessel anatomy, coronary opacification was always possible by means of the systemic contrast agent, and the aberrant coronary arteries were visualized synoptically in direct relation to the great mediastinal vessels. In contrast to MDCT, selective cannulation and final diagnosis was possible in only 11 of the 20 catheter angiograms performed (accuracy of 55.0%). In conclusion, its non-invasiveness and precise visualization makes MDCT the standard of reference for evaluating anomalous coronary arteries. (orig.)

  11. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  12. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  13. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    Science.gov (United States)

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  14. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  15. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  16. Radiation doses to patients receiving computed tomography examinations in British Columbia

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Bilawich, A.-M.; Mayo, J.R.

    2006-01-01

    To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen/pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen/pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany. (author)

  17. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Energy Technology Data Exchange (ETDEWEB)

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  18. Effects of dose reduction on multi-detector computed tomographic images in evaluating the maxilla and mandible for pre-surgical implant planning: a cadaveric study.

    Science.gov (United States)

    Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro

    2010-08-01

    To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.

  19. Study on multi-detector computed tomography in the virtual endoscope mode to phantom of saliva gland duct application. Image quality evaluation of geometry

    International Nuclear Information System (INIS)

    Ozawa, Tomonori; Innami, Hisashi; Oyake, Reira; Shinohara, Yuki; Yamaaki, Fumi; Koizumi, Nobuhide; Okumura, Yasuhiko

    2009-01-01

    The diagnosis ability of the radiographic imaging has been greatly improved by the advent of multi-detector computed tomography (MDCT), Which is now a the prerequisite to the diagnosis and treatment of a variety of diseases. MDCT conducted in the virtual endoscope mode can be used for various image compositions, and the space in a structure such as the large intestines can be visualized similarly as with an actual endoscope. Using a phantom of a salivary gland duct, I performed the image analysis to determine whether this endoscope mode could able to be applied to the oral cavity. I searched for the optimum conditions and the best position for taking pictures, and evaluated whether the salivary gland ducts could be reproducibly imitated by the phantom. Modulation transfer function (MTF), Wiener spectrum (WS) analysis were used to examined the utility of MDCT in the virtual endoscope mode for use in the oral cavity. As a result, the following conclusions were made: The best image was obtained within 40 mm from the center part of the gantry by the MTF and the WS analyses. Decreases in the MTF and the WS as the decrease were seen at 20 mAs and 80 kV, and the decrease were seen in the sharpness of the image decreased as the value of the reconstruction function became smaller. The image was somewhat distorted when pictures were taken of the parallel or the direction of the slice by the inclination within 90 deg±15 deg as much as possible Z axially for running of the duct in the evaluation of internal reproducibility. The influence was admitted to go out easily in an inside form as the inside diameter became thin. The salivary gland phantom was evaluated geometrically by MDCT in the virtual endoscope mode, and the optimal conditions were obtained from the above-mentioned results. The utility of MDCT in the mode was thus suggested. (author)

  20. Computed tomography myocardial perfusion vs {sup 15}O-water positron emission tomography and fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Michelle C.; Dweck, Marc R.; Golay, Saroj K. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); Mirsadraee, Saeed; Weir, Nicholas W.; Fletcher, Alison; Lucatelli, Christophe; Reid, John H. [University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); MacGillivray, Tom; Van Beek, Edwin J.R.; Newby, David E. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); Cruden, Nicholas L.; Henriksen, Peter A.; Uren, Neal [Edinburgh Heart Centre, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); McKillop, Graham; Patel, Dilip [Department of Radiology, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Lima, Joao A.C. [Johns Hopkins Hospital, Departments of Medicine and Radiology, Baltimore, MD (United States)

    2017-03-15

    Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with {sup 15}O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR). 51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by ''snapshot'' adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80. PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR. CT myocardial attenuation density correlates with {sup 15}O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD. (orig.)

  1. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  2. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  3. Estimation of aortic time-enhancement curve in pharmacokinetic analysis. Dynamic study by multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Kidoya, Eiji; Higashimura, Kyoji; Hayashi, Hiroyuki; Suzuki, Masayuki

    2007-01-01

    This paper presents an introduction to the development of software that provides a physiologic model of contrast medium enhancement by incorporating available physiologic data and contrast medium pharmacokinetics to predict an organ-specific aortic time-enhancement curve (TEC) in computed tomography (CT) with various contrast medium injection protocols in patients of various heights, weights, cardiac output levels, and so on. The physiologic model of contrast medium enhancement was composed of six compartments for early contrast enhancement pharmacokinetics. Contrast medium is injected via the antecubital vein and distributed to the right side of the heart, the pulmonary compartment, the left side of the heart, and the aorta. It then circulates back to the right side of the heart via the systemic circulation. A computer-based, compartmental model of the aortic system was generated using human physiologic parameters and six differential equations to describe the transport of contrast medium. Aortic TEC generated by the computer-based physiologic model of contrast medium enhancement showed validity and agreement with clinical data and findings published previously. A computer-based physiologic model that may help predict organ-specific CT contrast medium enhancement for different injection protocols was developed. Such a physiologic model may have multiple clinical applications. (author)

  4. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  5. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  6. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    International Nuclear Information System (INIS)

    Bartalena, Tommaso; Giannelli, Giovanni; Rinaldi, Maria Francesca; Rimondi, Eugenio; Rinaldi, Giovanni; Sverzellati, Nicola; Gavelli, Giampaolo

    2009-01-01

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  7. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  8. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  9. A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Funama, Yoshinori [Kumamoto University, Department of Radiological Sciences, School of Health Sciences, Kumamoto (Japan); Awai, Kazuo; Nakayama, Yoshiharu; Liu, Da; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Miyazaki, Osamu; Goto, Taiga [Hitachi Medical Corporation, Tokyo (Japan); Hori, Shinichi [Gate Tower Institute of Image Guided Therapy, Osaka (Japan)

    2006-04-15

    The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detector CT. We added an inhomogeneous texture to the simulated liver by referring to CT images of chronically damaged human livers. The mean CT number of the simulated liver was 60 HU and we added numerous 5-to 10-mm structures with 60{+-}10 HU/mm. To mimic liver tumors we added nodules measuring 8, 10, and 12 mm in diameter with CT numbers of 60{+-}10, 60{+-}15, and 60{+-}20 HU. Five radiologists visually evaluated similarity of the texture of the computer-simulated liver phantom and a real human liver to confirm the appropriateness of the virtual liver images using a five-point scale. The total score was 44 in two radiologists, and 42, 41, and 39 in one radiologist each. They evaluated that the textures of virtual liver were comparable to those of human liver. Our computer-simulated liver phantom is a promising tool for the evaluation of the image quality and diagnostic performance of hepatic CT imaging. (orig.)

  10. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    Nishida, Chikako; Okajima, Kaoru; Yamamoto, Takashi; Hattori, Ryuichi; Kudo, Takashi; Nishimura, Yasumasa

    2005-01-01

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  11. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  12. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  13. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  14. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  15. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon

    2013-01-01

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm 3 , 90.4%) than in calcified plaque (median, 0.7 mm 3 , 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  17. Computed tomography assessment of hip joints in asymptomatic individuals in relation to femoroacetabular impingement.

    Science.gov (United States)

    Kang, Alan C L; Gooding, Andrew J; Coates, Mark H; Goh, Tony D; Armour, Paul; Rietveld, John

    2010-06-01

    Femoroacetabular impingement has become a well-recognized entity predisposing to acetabular labral tears and chondral damage, and subsequently development of osteoarthritis of the hip joint. In the authors' experience, it is common to see bony abnormalities predisposing to femoroacetabular impingement in the contralateral asymptomatic hips in patients with unilateral femoroacetabular impingement. This study was undertaken to investigate the prevalence of bony abnormalities predisposing to femoroacetabular impingement in asymptomatic individuals without exposing study participants to unnecessary radiation. Cross-sectional study; Level of evidence, 4. Fifty individuals (100 hip joints), ranging from 15 to 40 years of age, who were seen at a local hospital between March and August 2008 with abdominal trauma or nonspecific abdominal pain in whom abdominal computed tomography was performed to aid diagnosis were prospectively studied. These patients were not known to have any history of hip-related problems. Raw data from the abdominal computed tomography scan, performed on a 64-slice multidetector computed tomography scanner, were reformatted using bone algorithm into several different planes. Several measurements and observations of the hip joints were made in relation to femoroacetabular impingement. The 100 hip joints from 50 patients with no history of hip problems demonstrated that 39% of the joints (31% of female, 48% of male joints) have at least 1 morphologic aspect predisposing to femoroacetabular impingement. The majority (66% to 100% ) of the findings were bilateral; 33% of female and 52% of male asymptomatic participants in our study had at least 1 predisposing factor for femoroacetabular impingement in 1 or both of their hip joints. Based on the data collected from this study, the acetabular crossover sign had a 71% sensitivity and 88% specificity for detecting acetabular retroversion. Nonquantitative assessment of the femoral head at the anterior

  18. Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography

    International Nuclear Information System (INIS)

    Elke, Gunnar; Weiler, Norbert; Frerichs, Inéz; Fuld, Matthew K; Halaweish, Ahmed F; Hoffman, Eric A; Grychtol, Bartłomiej

    2013-01-01

    Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (r s = 0.89 right, r s = 0.90 left lung) and after local injury (r s = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%±1.1% by EIT and 5.4%±1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level. (paper)

  19. Scimitar syndrome: multi detector computed tomography angiography findings of a case

    International Nuclear Information System (INIS)

    Aslan, A.; Bozlar, U.; Ors, F.; Tasar, M.

    2012-01-01

    Full text: Introduction: Scimitar syndrome also known as pulmonary venolobar syndrome is a rare congenital abnormality. This abnormality consists of ipsilateral anomalous pulmonary venous drainage of right lung into the inferior vena cava (IVC), with hypoplasia of the right lung, an anomalous systemic arterial supply from supradiaphragmatic aorta to the right lower lobe and dextrocardia. Objectives and tasks: In this article, we aimed to present multidetector computed tomography (MDCT) angiography findings of a case with scimitar syndrome. Material and methods: 21 year old male with dextrocardia and anomalous curvilinear density in the right lower lobe directed toward the right hemidiaphragm on chest radiography was evaluated with MDCT angiography examination. Results: Dextrocardia and interruption of IVC with azygous continuation was detected in MDCT angiography examination. Vertically directing right superior pulmonary vein was draining to the suprahepatic segment of IVC. Pulmonary sequestration in the right lower lobe taking feeder from celiac trunk was detected. Right pulmonary artery was hypoplastic and bronchial tree was abnormal, manifesting as a mirror image in both lung lobes. Conclusion: MDCT angiography is very successful imaging method in demonstrating the anomalous pulmonary vein and assessing pulmonary arterial and bronchial anomalies

  20. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  1. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  2. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  3. Imaging pitfalls, normal anatomy, and anatomical variants that can simulate disease on cardiac imaging as demonstrated on multidetector computed tomography

    International Nuclear Information System (INIS)

    Terpenning, Silanath; White, Charles S

    2015-01-01

    Advances in computed tomography have led to continuous improvement in cardiac imaging. Dedicated postprocessing capabilities, faster scan times, and cardiac gating methods reveal details of normal cardiac anatomy and anatomic variants that can mimic pathologic conditions. This article will review normal cardiac anatomy and variants that can mimic disease. Radiologists should be familiar with normal cardiac anatomy and anatomic variants to avoid misinterpretation of normal findings for pathologic processes

  4. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  5. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2013-12-15

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm{sup 3}, 90.4%) than in calcified plaque (median, 0.7 mm{sup 3}, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  8. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    Science.gov (United States)

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  9. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  10. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  11. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography.

    Science.gov (United States)

    Min, James K; Swaminathan, Rajesh V; Vass, Melissa; Gallagher, Scott; Weinsaft, Jonathan W

    2009-01-01

    The assessment of coronary stents with present-generation 64-detector row computed tomography scanners that use filtered backprojection and operating at standard definition of 0.5-0.75 mm (standard definition, SDCT) is limited by imaging artifacts and noise. We evaluated the performance of a novel, high-definition 64-slice CT scanner (HDCT), with improved spatial resolution (0.23 mm) and applied statistical iterative reconstruction (ASIR) for evaluation of coronary artery stents. HDCT and SDCT stent imaging was performed with the use of an ex vivo phantom. HDCT was compared with SDCT with both smooth and sharp kernels for stent intraluminal diameter, intraluminal area, and image noise. Intrastent visualization was assessed with an ASIR algorithm on HDCT scans, compared with the filtered backprojection algorithms by SDCT. Six coronary stents (2.5, 2.5, 2.75, 3.0, 3.5, 4.0mm) were analyzed by 2 independent readers. Interobserver correlation was high for both HDCT and SDCT. HDCT yielded substantially larger luminal area visualization compared with SDCT, both for smooth (29.4+/-14.5 versus 20.1+/-13.0; P<0.001) and sharp (32.0+/-15.2 versus 25.5+/-12.0; P<0.001) kernels. Stent diameter was higher with HDCT compared with SDCT, for both smooth (1.54+/-0.59 versus1.00+/-0.50; P<0.0001) and detailed (1.47+/-0.65 versus 1.08+/-0.54; P<0.0001) kernels. With detailed kernels, HDCT scans that used algorithms showed a trend toward decreased image noise compared with SDCT-filtered backprojection algorithms. On the basis of this ex vivo study, HDCT provides superior detection of intrastent luminal area and diameter visualization, compared with SDCT. ASIR image reconstruction techniques for HDCT scans enhance the in-stent assessment while decreasing image noise.

  12. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  13. Non-obstructive low attenuation coronary plaque predicts three-year acute coronary syndrome events in patients with hypertension. Multidetector computed tomographic study

    International Nuclear Information System (INIS)

    Nakanishi, Koki; Shimada, Kenei; Fukuda, Shota

    2012-01-01

    Arterial hypertension is an established risk factor for acute coronary syndrome (ACS). Multidetector computed tomography (MDCT) is an accurate and less invasive technique for assessment of the degree of coronary artery luminal narrowing and characterization of coronary atherosclerosis. We therefore aimed to investigate the predictive power of MDCT for future ACS events and compared with traditional parameters in patients with hypertension. One hundred and thirty-four patients (93 men, mean age 70±11 years) with hypertension underwent MDCT for evaluation of coronary artery disease. MDCT analysis focused on the presence of plaques, the degree of stenosis, and the plaque characteristics. Traditional parameters included Framingham risk score, carotid intima-media thickness, and left ventricular mass index. During a mean follow-up of 39±10 months, ACS events occurred in 10 patients, including myocardial infarction (n=3) and unstable angina (n=7). Multivariate analysis identified total number of low attenuation plaques as an independent predictor of ACS events (p<0.001). We demonstrated that non-obstructive low attenuation coronary plaques on MDCT predicted more accurately future ACS events in patients with hypertension than traditional parameters. (author)

  14. Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?

    Science.gov (United States)

    Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei

    2013-01-01

    The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  16. Multidetector CT Assessment of Lymph Node Size for Nodal Staging in Patients with Potentially Operable Squamous Esophageal Cancer and the 18F-FDG Positron Emission Tomography CT Correlation

    International Nuclear Information System (INIS)

    Yoom, Soo Kyung; Jung, Jung Im; Ahn, Myeong Im; Park, Jae Gil; Yoo, Ie Ryung; Park, Seog Hee; Park, Mi Jung; Park, Hyun Jin

    2010-01-01

    To investigate the size criteria of multidetector computed tomography (MDCT) for the evaluation metastatic lymph nodes (LNs) for potentially operable squamous esophageal cancer, and to compare this information with the results of positron emission tomography-CT (PET-CT). Twenty-four patients who underwent radical esophagectomy for esophageal cancer were studied. All patients had preoperative MDCT and PET-CT. The MDCT findings were compared with those of PET-CT and were correlated with the surgical records. The receiver operating characteristic (ROC) curve method was used to determine the appropriate cut-off value to distinguish benign from metastatic LNs. The size of metastatic LNs (9.35 ± 3.41 mm) was significantly larger than that of benign LNs (5.74 ± 1.64 mm) (p<0.001). The best cut-off value was 7 mm (81.8% sensitivity, 80.8% specificity). PET-CT detected all metastatic LNs except for four in the peritumoral region. The sensitivity and specificity of metastatic LN evaluation on PET-CT were 82.6% and 99.4%, respectively. Only one LN without metastasis showed increased fluoro-2-deoxy-D-glucose uptake on PET-CT. Size of metastatic LNs can typically be < 10 mm. For MDCT, the short diameter of 7 mm may be the optimal criterion. PET-CT is very accurate for the assessment of metastatic LNs except for those in the peritumoral region

  17. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  4. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  5. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  6. What Can Computed Tomography Scans of the Thorax Show after Breast Surgery?

    Directory of Open Access Journals (Sweden)

    Afsaneh Alikhassi

    2016-06-01

    Full Text Available Background: Postoperative breast abnormalities after breast conserving surgery or modified radical mastectomy are frequently overlooked and inaccurately assessed or reported using multidetector computed tomography (MDCT. These inaccurate results may have legal ramifications for the clinicians, cause patients avoidable anxiety, and lead to additional unnecessary diagnostic follow-up testing and costs.Methods: The patients with a history of breast cancer who had undergone breast-conserving surgery or modified radical mastectomy up to 6 months prior to undergoing a thoracic MDCT scan consented and enrolled in this study. These patients underwent a thoracic MDCT scan either because of respiratory or cardiac clinical symptoms or as part of breast cancer staging.Results: Forty women were included in this study. Different postoperative breast changes observed on thoracic MDCT scans including fibrous scar tissue, fat necrosis, seroma, abscess, hematoma, and recurrent and residual tumor were described.Conclusions: MDCT scans offer sufficient evidence in many postoperative cases to allow a confident diagnosis. General radiologists who review thoracic MDCT scans should know how to characterize breast lesions incidentally found on MDCT scans after breast surgeries. This information would enhance the value of the radiologist’s report for appropriate case management.

  7. Quantitative computer-aided diagnostic algorithm for automated detection of peak lesion attenuation in differentiating clear cell from papillary and chromophobe renal cell carcinoma, oncocytoma, and fat-poor angiomyolipoma on multiphasic multidetector computed tomography.

    Science.gov (United States)

    Coy, Heidi; Young, Jonathan R; Douek, Michael L; Brown, Matthew S; Sayre, James; Raman, Steven S

    2017-07-01

    To evaluate the performance of a novel, quantitative computer-aided diagnostic (CAD) algorithm on four-phase multidetector computed tomography (MDCT) to detect peak lesion attenuation to enable differentiation of clear cell renal cell carcinoma (ccRCC) from chromophobe RCC (chRCC), papillary RCC (pRCC), oncocytoma, and fat-poor angiomyolipoma (fp-AML). We queried our clinical databases to obtain a cohort of histologically proven renal masses with preoperative MDCT with four phases [unenhanced (U), corticomedullary (CM), nephrographic (NP), and excretory (E)]. A whole lesion 3D contour was obtained in all four phases. The CAD algorithm determined a region of interest (ROI) of peak lesion attenuation within the 3D lesion contour. For comparison, a manual ROI was separately placed in the most enhancing portion of the lesion by visual inspection for a reference standard, and in uninvolved renal cortex. Relative lesion attenuation for both CAD and manual methods was obtained by normalizing the CAD peak lesion attenuation ROI (and the reference standard manually placed ROI) to uninvolved renal cortex with the formula [(peak lesion attenuation ROI - cortex ROI)/cortex ROI] × 100%. ROC analysis and area under the curve (AUC) were used to assess diagnostic performance. Bland-Altman analysis was used to compare peak ROI between CAD and manual method. The study cohort comprised 200 patients with 200 unique renal masses: 106 (53%) ccRCC, 32 (16%) oncocytomas, 18 (9%) chRCCs, 34 (17%) pRCCs, and 10 (5%) fp-AMLs. In the CM phase, CAD-derived ROI enabled characterization of ccRCC from chRCC, pRCC, oncocytoma, and fp-AML with AUCs of 0.850 (95% CI 0.732-0.968), 0.959 (95% CI 0.930-0.989), 0.792 (95% CI 0.716-0.869), and 0.825 (95% CI 0.703-0.948), respectively. On Bland-Altman analysis, there was excellent agreement of CAD and manual methods with mean differences between 14 and 26 HU in each phase. A novel, quantitative CAD algorithm enabled robust peak HU lesion detection

  8. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  9. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  10. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    Science.gov (United States)

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  11. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  12. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  13. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  14. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  15. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  16. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Stahl, R.; Braunagel, M.; Kazmierczak, P.M.; Thierfelder, K.M.; Treitl, K.M.; Wirth, S. [University Hospital of Munich, LMU Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, M. [University Hospital Tuebingen, Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-08-15

    To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. (orig.)

  17. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  18. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  19. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  20. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Biscaldi, Ennio, E-mail: ennio.biscaldi@gmail.com [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy); Ferrero, Simone, E-mail: simone.ferrero@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Leone Roberti Maggiore, Umberto, E-mail: ulrm@libero.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Remorgida, Valentino, E-mail: vremorgida@yahoo.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Venturini, Pier Luigi, E-mail: venturini@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Rollandi, Gian Andrea, E-mail: rollandi@galliera.it [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy)

    2014-02-15

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis.

  1. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    International Nuclear Information System (INIS)

    Biscaldi, Ennio; Ferrero, Simone; Leone Roberti Maggiore, Umberto; Remorgida, Valentino; Venturini, Pier Luigi; Rollandi, Gian Andrea

    2014-01-01

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis

  2. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  3. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  6. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  7. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  9. Multidetector computed tomography for the assessment of adnexal Mass: Is unenhenced CT scan necessary?

    International Nuclear Information System (INIS)

    Jung, Sung Il; Park, Hee Sun; Kim, Young Jun; Jeon, Hae Jeong

    2014-01-01

    To compare the diagnostic performance and radiation dose between contrast-enhanced CT (ECT) alone, and combined unenhanced and contrast-enhanced CT (UE + ECT) for the assessment of adnexal mass. This retrospective study was approved by the Institutional Review Board. A total of 146 consecutive patients (mean age, 41.1 years) who underwent preoperative unenhanced and contrast-enhanced multidetector CT of the pelvis and had adnexal masses found at surgery were included. Two readers independently evaluated the likelihood of adnexal malignancy on a 5-point scale on two different imaging datasets (ECT alone and UE + ECT). The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Radiation dose to patients was calculated by the volume CT dose index (CTDIvol) and the dose length products (DLP) on each dataset. Of the total 178 adnexal masses, 133 masses were benign and 45 masses were malignant. For both readers, there is no significant difference of AUC values between ECT alone and UE + ECT for the detection of adnexal malignancy (reader 1, 0.93 vs. 0.95; reader 2, 0.92 vs. 0.91) (p > 0.05). The mean CTDIvol (12.6 ± 2.2 mGy) and DLP (641.2 ± 137.2 mGy) of ECT alone was significantly lower than the mean CTDIvol (21.5 ± 2.7 mGy) and DLP (923.6 ± 158.8 mGy) of UE + ECT (p < 0.0001). The use of unenhanced CT scan in addition to contrast-enhanced CT scan does not improve the detection of adnexal malignancy, but increases radiation exposure.

  10. Imaging of Herniated Discs of the Cervical Spine: Inter-Modality Differences between 64-Slice Multidetector CT and 1.5-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Ji Sook; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Han, Jong Kyu [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Kim, Hyun Joo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2015-08-15

    To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI.

  11. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  12. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  13. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  14. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  15. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  16. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  17. Criteria for the selective use of chest computed tomography in blunt trauma patients

    International Nuclear Information System (INIS)

    Brink, Monique; Dekker, Helena M.; Kool, Digna R.; Blickman, Johan G.; Deunk, Jaap; Edwards, Michael J.R.; Vugt, Arie B. van; Kuijk, Cornelis van

    2010-01-01

    The purpose of this study was to derive parameters that predict which high-energy blunt trauma patients should undergo computed tomography (CT) for detection of chest injury. This observational study prospectively included consecutive patients (≥16 years old) who underwent multidetector CT of the chest after a high-energy mechanism of blunt trauma in one trauma centre. We included 1,047 patients (median age, 37; 70% male), of whom 508 had chest injuries identified by CT. Using logistic regression, we identified nine predictors of chest injury presence on CT (age ≥55 years, abnormal chest physical examination, altered sensorium, abnormal thoracic spine physical examination, abnormal chest conventional radiography (CR), abnormal thoracic spine CR, abnormal pelvic CR or abdominal ultrasound, base excess <-3 mmol/l and haemoglobin <6 mmol/l). Of 855 patients with ≥1 positive predictors, 484 had injury on CT (95% of all 508 patients with injury). Of all 192 patients with no positive predictor, 24 (13%) had chest injury, of whom 4 (2%) had injuries that were considered clinically relevant. Omission of CT in patients without any positive predictor could reduce imaging frequency by 18%, while most clinically relevant chest injuries remain adequately detected. (orig.)

  18. Criteria for the selective use of chest computed tomography in blunt trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Brink, Monique; Dekker, Helena M.; Kool, Digna R.; Blickman, Johan G. [Radboud University Nijmegen, Medical Centre, Department of Radiology, Nijmegen (Netherlands); Deunk, Jaap; Edwards, Michael J.R. [Radboud University Nijmegen, Medical Centre, Department of Surgery, Nijmegen (Netherlands); Vugt, Arie B. van [Radboud University Nijmegen, Medical Centre Nijmegen, Department of Emergency Medicine, Nijmegen (Netherlands); Kuijk, Cornelis van [VU (Vrije Universiteit) University, Medical Center Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2010-04-15

    The purpose of this study was to derive parameters that predict which high-energy blunt trauma patients should undergo computed tomography (CT) for detection of chest injury. This observational study prospectively included consecutive patients ({>=}16 years old) who underwent multidetector CT of the chest after a high-energy mechanism of blunt trauma in one trauma centre. We included 1,047 patients (median age, 37; 70% male), of whom 508 had chest injuries identified by CT. Using logistic regression, we identified nine predictors of chest injury presence on CT (age {>=}55 years, abnormal chest physical examination, altered sensorium, abnormal thoracic spine physical examination, abnormal chest conventional radiography (CR), abnormal thoracic spine CR, abnormal pelvic CR or abdominal ultrasound, base excess <-3 mmol/l and haemoglobin <6 mmol/l). Of 855 patients with {>=}1 positive predictors, 484 had injury on CT (95% of all 508 patients with injury). Of all 192 patients with no positive predictor, 24 (13%) had chest injury, of whom 4 (2%) had injuries that were considered clinically relevant. Omission of CT in patients without any positive predictor could reduce imaging frequency by 18%, while most clinically relevant chest injuries remain adequately detected. (orig.)

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  20. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  1. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  4. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  5. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  6. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  7. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  8. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  9. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  16. Multidetector row computed tomography findings from ischemia to infarction of the large bowel

    International Nuclear Information System (INIS)

    Romano, Stefania; Romano, Luigia; Grassi, Roberto

    2007-01-01

    Objective: MDCT is performed as first imaging examination for patients with acute abdomen in most Emergency Departments. Clinical suspicion of ischemic colitis and infarction is related to specific findings, however, differential diagnosis as well as the staging for a confirmed ischemic affection may be critical. The individual signs from ischemia to infarction of large bowel is a captivating topic. In this study, we report our experience of the MDCT assessment of acute colonic disease from vascular mesenteric disorders. Materials and methods: We retrospectively reviewed the MDCT findings of 71 patients admitted to our attention for acute abdomen, with final proven diagnosis of colonic ischemia and/or infarction made by surgery and/or endoscopy. CT-scanning of the abdomen and pelvis was performed after i.v. contrast medium administration, using a multidetector row CT equipment. We correlated the presence of parietal disease, the evidence of mesenteric arterial or venous vessels occlusion, the parietal features as well as others findings, such as free fluid and/or air in peritoneal recess or in retroperitoneum, with the surgical and/or endoscopic findings. Results: Analysis of our data showed a segmental (84%) or complete (16%) involvement of the colon; 57 cases were related to ischemia, 14 to infarction. Inferior mesenteric vessels defect of opacification was noted in 10 cases. Various degree of wall thickening and parietal enhancement, peritoneal fluid, mural or portal-mesenteric pneumatosis were compared to evidence of mesenteric arterial or vein occlusion and to final proven diagnosis. A classification in a multi-stage grading for both decreased of arterial supply or impaired venous drainage disorders was done. Conclusions: A grading scale from ischemia to infarction affecting the large bowel from arterial or venous mesenteric vessels origin has been not previously reported in a series at our knowledge. MDCT findings may support the clinical evaluation of

  17. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  18. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  20. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  1. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  2. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    Science.gov (United States)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p DTPA-enhanced MRI had a higher

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  4. Comparative study of single and multislice computed tomography for assessment of the mandibular canal

    Directory of Open Access Journals (Sweden)

    Adriana da Silva Ferreira Paes

    2007-06-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the accuracy of relative measurements from the roof of the mandibular canal to the alveolar crest in multislice (multidetector computed tomography (MDCT and single-slice computed tomography (SSCT. MATERIAL AND METHODS: The sample consisted of 26 printed CT films (7 SSCT and 19 MDCT from the files of the LABI-3D (3D Imaging Laboratory of the School of Dentistry of the University of São Paulo (FOUSP, which had been acquired using different protocols. Two observers analyzed in a randomized and independent order a series of 22 oblique CT reconstructions of each patient. Each observer analyzed the CT scans twice. The length of the mandibular canal and the distance between the mandibular canal roof and the crest of the alveolar ridge were obtained. Dahlberg test was used for statistical analysis. RESULTS: The mean error found for the mandibular canal length measurements obtained from SSCT was 0.53 mm in the interobserver analysis, and 0.38 mm for both observers. On MDCT images, the mean error was 0.0 mm in the interobserver analysis, and 0.0 and 0.23 mm in the intraobserver analysis. Regarding the distance between the mandibular canal roof and the alveolar bone crest, the SSCT images showed a mean error of 1.16 mm in the interobserver analysis and 0.66 and 0.59 mm in the intraobserver analysis. In the MDCT images, the mean error was 0.72 mm in the interobserver analysis and 0.50 and 0.54 mm in the intraobserver analysis. CONCLUSION: Multislice CT was demonstrated a more accurate method and demonstrated high reproducibility in the analysis of important anatomical landmarks for planning of mandibular dental implants, namely the mandibular canal pathway and alveolar crest height.

  5. 320-row detector computed tomography angiography findings of a case with multiple

    International Nuclear Information System (INIS)

    Akay, S.; Bozlar, U.; Demirkol, S.; Tasar, M.

    2012-01-01

    Full text: Introduction: Computed tomography angiography (CTA) with three-dimensional imaging capability is a very reliable imaging modality for the evaluation of the coronary arteries. Objectives and tasks: To discuss the 320-row detector CTA findings of a case with multiple coronary artery course anomaly. Materials and methods: A 46-year-old man with palpitation, admitted to Cardiology department of our hospital. On electrocardiography, polymorphic ventricular early beats were observed. The patient was referred to Radiology department for CTA examination in terms of probable coronary artery anomaly. Results: On CTA, left main coronary artery was short. The bridging causes nearly 75% luminal stenosis was observed in the middle part of left descending artery. Circumflex artery was continuing as the first obtuse margin and this branch was separating to four branches in the middle part. They were coursing subepicardially in the middle and distal part. Right main coronary artery has also subepicardial course in its middle and distal part. Conclusion: Myocardial bridging is not a rare situation in routine clinical practice. But bridging in all of the three coronary arteries is very uncommon. Multidetector CTA is an effective and non-invasive imaging modality for understanding the normal anatomy and detecting the congenital anomalies of the coronary arteries

  6. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  7. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit to examine ... CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to contrast ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits Using a multidetector CT unit to examine children is faster than the older ... clearly needed. Another strategy is to consider other tests, such as MRI or ultrasound which might give ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... best for your child. top of page Additional Information and Resources The Alliance for Radiation Safety in ...

  12. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  13. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  14. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  15. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  16. Measurement of Trabecular Bone Parameters in Porcine Vertebral Bodies Using Multidetector CT: Evaluation of Reproducibility of 3-Dimensional CT Histomorphometry

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Hwan; Goo, Jin Mo [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Moon Kyung Chul [Dept. of Pathology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); An, Sang Bu [Dept. of radiology, National Cancer Center, Goyang (Korea, Republic of); Kim, Kwang Gi [Dept. of Biomedical Engineering, Division of Basic and Applied Sciences, National Cancer Center, Goyang (Korea, Republic of)

    2011-05-15

    To evaluate the reproducibility of 3-dimensional histomorphometry for the microarchitecture analysis of trabecular bone parameters using multidetector computed tomography (MDCT). Thirty-six specimens from porcine vertebral bodies were imaged five times with a 64- detector row MDCT system using the same scan protocols. Locations of the specimens were nearly identical through the scans. Three-dimensional structural parameters of trabecular bone were derived from the five data sets using image analyzing software. The features measured by the analysis programs were trabecular bone volume, trabecular bone volume/tissue volume, trabecular thickness, trabecular separation, trabecular number, trabecular bone pattern factor, structural model index. The structural trabecular parameters showed excellent reproducibility through repeated scanning. Intraclass correlation coefficients of all seven structural parameters were in the range of 0.998 to 1.000. Coefficients of variation of the six structural parameters, excluding structural model index, were not over 1.6%. The measurement of the trabecular structural parameters using multidetector CT and three-dimensional histomophometry analysis program was validated and showed excellent reproducibility. This method could be used as a noninvasive and easily available test in a clinical setting.

  17. The MDCT and MRI Findings of a Pancreatic Arteriovenous Malformation Combined with Isolated Dissection of the Superior Mesenteric Artery: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeong, Woo Kyoung [Hanyang University Guri Hospital, Seoul (Korea, Republic of); Kim, Jin Oo [Naval Pohang Hospital, Pohang (Korea, Republic of); Oh, Ji Young; Song, Soon Young [Hanyang University Medical College, Seoul (Korea, Republic of)

    2010-03-15

    Pancreatic arteriovenous malformation and isolated spontaneous dissection of the superior mesenteric artery are both rare maladies, and now they can be easily diagnosed due to the development of such noninvasive modalities as multi-detector computed tomography and magnetic resonance imaging. We report here on the multi-detector computed tomography and magnetic resonance imaging findings of a rare case of pancreatic arteriovenous malformation combined with isolated dissection of the superior mesenteric artery.

  18. The MDCT and MRI Findings of a Pancreatic Arteriovenous Malformation Combined with Isolated Dissection of the Superior Mesenteric Artery: A Case Report

    International Nuclear Information System (INIS)

    Kim, Yong Soo; Jeong, Woo Kyoung; Kim, Jin Oo; Oh, Ji Young; Song, Soon Young

    2010-01-01

    Pancreatic arteriovenous malformation and isolated spontaneous dissection of the superior mesenteric artery are both rare maladies, and now they can be easily diagnosed due to the development of such noninvasive modalities as multi-detector computed tomography and magnetic resonance imaging. We report here on the multi-detector computed tomography and magnetic resonance imaging findings of a rare case of pancreatic arteriovenous malformation combined with isolated dissection of the superior mesenteric artery

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...