WorldWideScience

Sample records for multichannel automated chamber

  1. A multichannel automated chamber system for continuous measurement of forest soil CO2 efflux

    International Nuclear Information System (INIS)

    Liang, N.; Inoue, G.; Fujinuma, Y.

    2003-01-01

    Development of a fast-response multi-chamber system for measuring soil-surface carbon dioxide efflux is described. The sixteen-chamber automated system continuously monitors surface carbon dioxide efflux at different locations within a forest ecosystem using a single infrared gas analyzer that successively measures gas samples from each of the sixteen chambers. The chambers have lids that open and close automatically, and are connected in parallel to the single carbon dioxide analyzer which is equipped with a sixteen-channel gas sampler. Air is withdrawn continuously from the inlets and outlets of each chamber and fed sequentially to the gas analyzer. Using this instrument, surface carbon dioxide efflux was measured in a 40-year old pine forest during a three-month period (February to May) in 2001. Results showed a steady increase in mean carbon dioxide efflux during the period. A statistically significant correlation between soil-surface carbon dioxide efflux and surface temperature was also established. Spatial variation of carbon dioxide efflux was found to be higher in the non-growing season than in the growing season. It was concluded that the multi-channel automated chamber system can provide large amounts of high quality data on soil carbon dioxide efflux over a large surface area and simultaneously evaluate both spatial and temporal variation. The system uses a relatively small amount of power (70 W maximum) which can be further reduced (to 15 W) by minimizing the pressure difference between inside and outside the chamber. The system requires no maintenance other than the calibration of the gas analyzer and measurement of the flow rate through the chambers. 34 refs., 8 figs

  2. Software for an automated processing system for radioisotope information from multichannel radiodiagnostic instruments

    International Nuclear Information System (INIS)

    Zelenin, P.E.; Meier, V.P.

    1985-01-01

    The SAORI-01 system for the automated processing of radioisotope information is designed for the collection, processing, and representation of information coming from gamma chambers and multichannel radiodiagnostic instruments (MRI) and is basically oriented toward the radiodiagnostic laboratories of major multidisciplinary hospitals and scientific-research institutes. The functional characteristics of the basic software are discussed, and permits performance of the following functions: collection of information regarding MRI; processing and representation of recorded information; storage of patient files on magnetic carriers; and writing of special processing programs in the FORTRAN and BASIC high-level language

  3. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    International Nuclear Information System (INIS)

    Nasr, Amgad

    2012-01-01

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N 2 , Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  4. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Amgad

    2012-07-18

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N{sub 2}, Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  5. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  6. BOREAS TF-3 Automated Chamber CO2 Flux Data from the NSA-OBS

    Science.gov (United States)

    Goulden, Michael L.; Crill, Patrick M.; Hall, Forrest G. (Editor); Conrad, Sara (Editor)

    2000-01-01

    The BOReal Ecosystem Atmosphere Study Tower Flux (BOREAS TF-3) and Trace Gas Biogeochemistry (TGB-1) teams collected automated CO2 chamber flux data in their efforts to fully describe the CO2 flux at the Northern Study Area-Old Black Spruce (NSA-OBS) site. This data set contains fluxes of CO2 at the NSA-OBS site measured using automated chambers. In addition to reporting the CO2 flux, it reports chamber air temperature, moss temperature, and light levels during each measurement. The data set covers the period from 23-Sep-1995 through 26-Oct-1995 and from 28-May-1996 through 21-Oct-1996. The data are stored in tabular ASCII files.

  7. Multichannel Mars Organic Analyzer (McMOA): Microfluidic Networks for the Automated In Situ Microchip Electrophoretic Analysis of Organic Biomarkers on Mars

    Science.gov (United States)

    Chiesl, T. N.; Benhabib, M.; Stockton, A. M.; Mathies, R. A.

    2010-04-01

    We present the Multichannel Mars Organic Analyzer (McMOA) for the analysis of Amino Acids, PAHs, and Oxidized Carbon. Microfluidic architecures integrating automated metering, mixing, on chip reactions, and serial dilutions are also discussed.

  8. Potentials and challenges associated with automated closed dynamic chamber measurements of soil CO2 fluxes

    Science.gov (United States)

    Görres, Carolyn-Monika; Kammann, Claudia; Ceulemans, Reinhart

    2015-04-01

    Soil respiration fluxes are influenced by natural factors such as climate and soil type, but also by anthropogenic activities in managed ecosystems. As a result, soil CO2 fluxes show a large intra- and interannual as well as intra- and intersite variability. Most of the available soil CO2 flux data giving insights into this variability have been measured with manually closed static chambers, but technological advances in the past 15 years have also led to an increased use of automated closed chamber systems. The great advantage of automated chambers in comparison to manually operated chambers is the higher temporal resolution of the flux data. This is especially important if we want to better understand the effects of short-term events, e.g. fertilization or heavy rainfall, on soil CO2 flux variability. However, the chamber method is an invasive measurement method which can potentially alter soil CO2 fluxes and lead to biased measurement results. In the peer-reviewed literature, many papers compare the field performance and results of different closed static chamber designs, or compare manual chambers with automated chamber systems, to identify potential biases in CO2 flux measurements, and thus help to reduce uncertainties in the flux data. However, inter-comparisons of different automated closed dynamic chamber systems are still lacking. Here we are going to present a field comparison of the most-cited automated chamber system, the LI-8100A Automated Soil Flux System, with the also commercially available Greenhouse Gas Monitoring System AGPS. Both measurement systems were installed side by side at a recently harvested poplar bioenergy plantation (POPFULL, http://uahost.uantwerpen.be/popfull/) from April 2014 until August 2014. The plantation provided optimal comparison conditions with a bare field situation after the harvest and a regrowing canopy resulting in a broad variety of microclimates. Furthermore, the plantation was planted in a double-row system with

  9. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...

  10. Annual Net Ecosystem Productivity of Wetlands: A Comparison of Automated and Manual Chamber Methods

    Science.gov (United States)

    Burrows, E. H.; Bubier, J. L.; Mosedale, A.; Crill, P. M.

    2001-05-01

    Net Ecosystem Exchange (NEE) of carbon dioxide (CO2) was measured in a minerotrophic poor fen in southeastern New Hampshire during the 2000 growing season using two types of chamber methods. Instantaneous CO2 flux was measured with transparent lexan and teflon static climate controlled chambers by calculating the change in headspace CO2 concentration in the chamber over time. Once per week the flux was sampled from ten manually operated chambers using a LI-COR 6200 portable photosynthesis system, which included a LI-6250 infrared gas analyzer, connected to the chambers. Ten automated chambers were installed in May of 2000, sampling CO2 flux every three hours over the diurnal cycle using a LI-COR 6262 infrared gas analyzer. The chambers and collars were placed throughout the fen in order to sample the range of plant communities. The manual sampling was done during the middle of the day, but the rate of photosynthesis changes depending on the amount of photosynthetically active radiation (PAR). In order to simulate varying light levels, shrouds blocking different amounts of light were placed over each manual chamber. An opaque shroud was used to measure respiration. NEE ranged from -13.0 to 12.5 μ mol CO2/m2/s in the manual chambers and -16.2 to 11.8 μ mol CO2/m2/s in the automated chambers for the mid-summer growing season. Manual respiration fluxes were measured under higher temperature regimes and the response of respiration to temperature will be factored in when comparing the two chamber techniques. Research during the summer of 2001 will also include diurnal measurements. Growing season net ecosystem productivity (NEP) will be estimated and compared for the two chamber systems. Several models will be used to estimate the flux when the manual chambers were not being sampled. The models will be based on biomass and dominant species in each chamber, and various environmental factors including water table, pH, relative humidity, PAR, air and peat temperature

  11. Electronic system for the automation of current measurements produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro da Silva

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology in the determination of radionuclide activity. For this purpose measurements of very low ionization currents, in the range of 10 -8 to 10 -14 A, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. In the present work, an automation system, developed for current integration measurements at the Laboratorio de Metrologia Nuclear (LMN) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card CAD12/32 (LYNX Tecnologia Eletronica Ltda.). Measurements, using an electrometer Keithley 616 (Keithley Instruments, Inc) and an ionization chamber IG12/A20 (20 th Century Electronics Ltd.), were performed in order to check the system and for validating the project. (author)

  12. Long-term monitoring of soil gas fluxes with closed chambers using automated and manual systems

    Energy Technology Data Exchange (ETDEWEB)

    Scott, A.; Crichton, I.; Ball, B.C.

    1999-10-01

    The authors describe two gas sample collection techniques, each of which is used in conjunction with custom made automated or manually operated closed chambers. The automated system allows automatic collection of gas samples for simultaneous analysis of multiple trace gas efflux from soils, permitting long-term monitoring. Since the manual system is cheaper to produce, it can be replicated more than the automated and used to estimate spatial variability of soil fluxes. The automated chamber covers a soil area of 0.5 m{sup 2} and has a motor driven lid that remains operational throughout a range of weather conditions. Both systems use gas-tight containers of robust metal construction, which give good sample retention, thereby allowing long-term storage and convenience of transport from remote locations. The containers in the automated system are filled by pumping gas from the closed chamber via a multiway rotary valve. Stored samples from both systems are analyzed simultaneously for N{sub 2}O and CO{sub 2} using automated injection into laboratory-based gas chromatographs. The use of both collection systems is illustrated by results from a field experiment on sewage sludge disposal to land where N{sub 2}O fluxes were high. The automated gas sampling system permitted quantification of the marked temporal variability of concurrent N{sub 2}O and CO{sub 2} fluxes and allowed improved estimation of cumulative fluxes. The automated measurement approach yielded higher estimates of cumulative flux because integration of manual point-in-time observations missed a number of transient high-flux events.

  13. The automated stringing system for the BaBar drift chamber

    International Nuclear Information System (INIS)

    Borsato, E.; Caracciolo, R.; Fanin, C.; Galeazzi, F.; Morandin, M.; Santi, S.; Voci, C.; Bronzini, F.; Buccheri, A.; Ferroni, F.; Fratini, K.; Morganti, S.; Patel, P.M.; Pelosi, A.; Piredda, G.; Fernholz, R.; Henderson, R.; Kelsey, M.

    2000-01-01

    After discussing the motivations for the project, the automated equipment used for the BaBar Drift Chamber stringing is described. Details are given mainly concerning the crucial points of setting-up and calibration. The focus is on the high accuracy reached by a large and complex mechanical tool

  14. Automated seismic waveform location using Multichannel Coherency Migration (MCM)-I. Theory

    Science.gov (United States)

    Shi, Peidong; Angus, Doug; Rost, Sebastian; Nowacki, Andy; Yuan, Sanyi

    2018-03-01

    With the proliferation of dense seismic networks sampling the full seismic wavefield, recorded seismic data volumes are getting bigger and automated analysis tools to locate seismic events are essential. Here, we propose a novel Multichannel Coherency Migration (MCM) method to locate earthquakes in continuous seismic data and reveal the location and origin time of seismic events directly from recorded waveforms. By continuously calculating the coherency between waveforms from different receiver pairs, MCM greatly expands the available information which can be used for event location. MCM does not require phase picking or phase identification, which allows fully automated waveform analysis. By migrating the coherency between waveforms, MCM leads to improved source energy focusing. We have tested and compared MCM to other migration-based methods in noise-free and noisy synthetic data. The tests and analysis show that MCM is noise resistant and can achieve more accurate results compared with other migration-based methods. MCM is able to suppress strong interference from other seismic sources occurring at a similar time and location. It can be used with arbitrary 3D velocity models and is able to obtain reasonable location results with smooth but inaccurate velocity models. MCM exhibits excellent location performance and can be easily parallelized giving it large potential to be developed as a real-time location method for very large datasets.

  15. Semi-automated high-efficiency reflectivity chamber for vacuum UV measurements

    Science.gov (United States)

    Wiley, James; Fleming, Brian; Renninger, Nicholas; Egan, Arika

    2017-08-01

    This paper presents the design and theory of operation for a semi-automated reflectivity chamber for ultraviolet optimized optics. A graphical user interface designed in LabVIEW controls the stages, interfaces with the detector system, takes semi-autonomous measurements, and monitors the system in case of error. Samples and an optical photodiode sit on an optics plate mounted to a rotation stage in the middle of the vacuum chamber. The optics plate rotates the samples and diode between an incident and reflected position to measure the absolute reflectivity of the samples at wavelengths limited by the monochromator operational bandpass of 70 nm to 550 nm. A collimating parabolic mirror on a fine steering tip-tilt motor enables beam steering for detector peak-ups. This chamber is designed to take measurements rapidly and with minimal oversight, increasing lab efficiency for high cadence and high accuracy vacuum UV reflectivity measurements.

  16. Automated flux chamber for investigating gas flux at water-air interfaces.

    Science.gov (United States)

    Duc, Nguyen Thanh; Silverstein, Samuel; Lundmark, Lars; Reyier, Henrik; Crill, Patrick; Bastviken, David

    2013-01-15

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Representative measurements of GHG fluxes from aquatic ecosystems to the atmosphere are vital for quantitative understanding of relationships between biogeochemistry and climate. Fluxes occur at high temporal variability at diel or longer scales, which are not captured by traditional short-term deployments (often in the order of 30 min) of floating flux chambers. High temporal frequency measurements are necessary but also extremely labor intensive if manual flux chamber based methods are used. Therefore, we designed an inexpensive and easily mobile automated flux chamber (AFC) for extended deployments. The AFC was designed to measure in situ accumulation of gas in the chamber and also to collect gas samples in an array of sample bottles for subsequent analysis in the laboratory, providing two independent ways of CH(4) concentration measurements. We here present the AFC design and function together with data from initial laboratory tests and from a field deployment.

  17. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Santos, D.M.; Chau, A.; DeBusshere, D.; Dow, S.; Flasck, J.; Levi, M.; Kirsten, F.; Su, E.

    1995-12-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e. 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using one eight channel TDC comprised of a delay locked loop and eight sets of latches and encoders. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. The timing and amplitude information is multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are then transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in a 0.8μ triple metal CMOS process. The TDC sub-element has been measured to have better than 135 ps time resolution and 35 ps jitter. The DRAM has a measured cycle time of 80 MHz

  18. MPS II drift chamber system

    International Nuclear Information System (INIS)

    Platner, E.D.

    1982-01-01

    The MPS II detectors are narrow drift space chambers designed for high position resolution in a magnetic field and in a very high particle flux environment. Central to this implementation was the development of 3 multi-channel custom IC's and one multi-channel hybrid. The system is deadtimeless and requires no corrections on an anode-to-anode basis. Operational experience and relevance to ISABELLE detectors is discussed

  19. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Chau, A.; DeBusschere, D.; Dow, S.F.; Flasck, J.; Levi, M.E.; Kirsten, F.; Su, E.; Santos, D.M.

    1996-01-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e., 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using an TDC comprised of a delay locked loop, latch and encoder. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. Eight complete channels of timing and amplitude information are multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are subsequently transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in an 0.8 microm triple metal CMOS process. The measured results indicate that the differential non-linearities of the TDC and the FADC are 200 ps and 10 mV, respectively. The integral nonlinearities of the TDC and the FADC are 230 ps and 9 mV, respectively

  20. A Portable, Low-Power Analyzer and Automated Soil Flux Chamber System for Measuring Wetland GHG Emissions

    Science.gov (United States)

    Nickerson, Nick; Kim-Hak, David; McArthur, Gordon

    2017-04-01

    Preservation and restoration of wetlands has the potential to help sequester large amounts of carbon due to the naturally high primary productivity and slow turnover of stored soil carbon. However, the anoxic environmental conditions present in wetland soils are also the largest natural contributor to global methane emissions. While it is well known that wetlands are net carbon sinks over long time scales, given the high global warming potential of methane, the short-term balances between C uptake and storage and loss as CO2 and CH4 need to be carefully considered when evaluating the climate effects of land-use change. It is relatively difficult to measure methane emissions from wetlands with currently available techniques given the temporally and spatially sporadic nature of the processes involved (methanogenesis, methane oxidation, ebullition, etc.). For example, using manual soil flux chambers can often only capture a portion of either the spatial or temporal variability, and often have other disadvantages associated with soil atmosphere disturbance during deployment in these relatively compressible wetland soils. Automated chamber systems offer the advantage of collecting high-resolution time series of gaseous fluxes while reducing some human and method induced biases. Additionally, new laser-based analyzers that can be used in situ alongside automated chambers offer a greater minimum detectable flux than can be achieved using alternative methods such as Gas Chromatography. Until recently these types of automated measurements were limited to areas that had good power coverage, as laser based systems were power intensive and could not easily be supplemented with power from field-available sources such as solar. Recent advances in laser technology has reduced the power needed and made these systems less power intensive and more field portable in the process. Here we present data using an automated chamber system coupled to a portable laser based greenhouse gas

  1. Subject-specific optimization of channel currents for multichannel transcranial magnetic stimulation.

    Science.gov (United States)

    Cline, Christopher C; Johnson, Nessa N; He, Bin

    2015-01-01

    The goal of this work is to develop a focal transcranial magnetic stimulation (TMS) system using a multichannel coil array for high-resolution neuromodulation. We proposed a novel spatially-distributed stimulation strategy to significantly improve the focality of TMS. Computer simulations were conducted to evaluate the proposed approach and test the merits of multichannel TMS. Three different multichannel coil arrays were modeled in addition to a conventional figure-8 coil for comparison. Simulations were performed on finite element head models of six subjects constructed from anatomical MR images via an automated pipeline. Multichannel TMS arrays exhibited significantly more focal induced electric field magnitudes compared to the figure-8 coil. Additionally, electrical steering of stimulation sites without physical movement of the coil array was demonstrated.

  2. A multi-channel waveform digitizer system

    International Nuclear Information System (INIS)

    Bieser, F.; Muller, W.F.J.

    1990-01-01

    The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus

  3. Calculational-theoretical studies of the system of local automated regulators and lateral ionization chambers

    International Nuclear Information System (INIS)

    Aleksakov, A.N.; Emel'yanov, I.Ya.; Nikolaev, E.V.; Panin, V.M.; Podlazov, L.N.; Rogova, V.D.

    1987-01-01

    Methods of engineering synthesis of the systems for nuclear reactor local automated power regulation and radial-azimuthal energy distribution stabilization operating according to lateral ionization chamber signals are described. Results of calculational-theoretical investigations into the system efficiency and peculiarities of its reaction to some perturbations typical of the RBMK type reactors are considered

  4. Automated analysis of angle closure from anterior chamber angle images.

    Science.gov (United States)

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  5. Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Cho, Chan Hee; Cho, Hyun Joon

    2009-01-01

    Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needs for development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

  6. Miniature multichannel analyzer for process monitoring

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.; Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.; Wiig, L.G.; Ianakiev, K.D.

    1993-01-01

    A new, 4,000-channel analyzer has been developed for gamma-ray spectroscopy applications. A design philosophy of hardware and software building blocks has been combined with design goals of simplicity, compactness, portability, and reliability. The result is a miniature, modular multichannel analyzer (MMMCA), which offers solution to a variety of nondestructive assay (NDA) needs in many areas of general application, independent of computer platform or operating system. Detector-signal analog electronics, the bias supply, and batteries are included in the virtually pocket-size, low-power MMMCA unit. The MMMCA features digital setup and control, automated data reduction, and automated quality assurance. Areas of current NDA applications include on-line continuous (process) monitoring, process material holdup measurements, and field inspections

  7. Multichannel thickener of flotation tailings

    Energy Technology Data Exchange (ETDEWEB)

    Kondratenko, A F; Shuliko, A N; Zinchenko, A F

    1983-04-01

    A multichannel thickener of flotation tailings developed by Ukrniiugleobogashchenie is described. Tailings with solid content ranging from 40 to 60 g/l are mixed with flocculation reagents (quantity ratio from 60 to 70 g/l) in a turbulent mixer: waste water with tailings fed to the mixer is divided into three streams, flocculation reagents are batched in stages with each water stream. After turbulent mixing, water, tailings and reagent are fed to the settling chamber. Settling chamber (dimensions 2.4 x 1.5 x 1.0 m) is divided into a number of channels by settling surfaces of 0.35 m/sup 2/ each, inclined at an angle of 55 degrees. Distance between the surfaces is 50 mm. The thickener has a total settling surface of 18.7 m/sup 2/. Water with tailings flows upwards, cleaned water is removed by a separating system and settled tailings move downward and accumulate in the compacting chamber (dimensions 1.5 x 1.5 x 0.9 m). From the compacting chamber thickened slurry with solid content from 90 to 150 g/l is removed by a hydraulic system. During performance testing in some plants preparing coal difficult to wash, thickening efficiency amounted to 100%. The results of performance testing are shown in two tables. Factors which influence thickener productivity are evaluated. (In Russian)

  8. Automated system with LabVIEW for the obtention of voltage plateau, graphic of sensitivity and operation voltage in an ionization chamber

    International Nuclear Information System (INIS)

    Cruz E, P.

    2001-01-01

    The work developed for the Laguna Verde Nuclear Power Central allows to obtain the voltage plateau, graphic of sensitivity and operation voltage of three types of ionization chambers which are used in their monitoring systems of process radiation. The automated system is based in a personal computer (Pc) for controlling and acquiring data from the different instruments used, its programming was realized with virtual instruments (LabVIEW, National Instruments software). The system also realizes a diagnosis of the ionization chamber and determine whether the parameters obtained are inside of the manufacturer specifications, that is to say, it determines when the ionization chamber must be replaced. (Author)

  9. A multichannel magnetic β-ray spectrometer for rapid measurements of electron spectra

    International Nuclear Information System (INIS)

    Kariya, Komyo; Morikawa, Kaoru.

    1989-01-01

    In order to make the magnetic β-ray spectrometer suitable for rapid measurements of electron spectra with short-lived nuclides, twelve small GM counters have been arrayed along the focal plane of a 180deg focusing flat type design. All the signal pulses from each one of these detectors are mixed together onto a single cable. By means of multichannel PHA, each pulse can be traced back to the specific detector which sent it out. In order to avoid time consuming evacuation procedures, the sample source is placed outside a thin window of the preevacuated analyzer chamber. By the use of this multichannel spectrometer a β-ray spectrum with maximum energy up to about 10 MeV can be measured within 1 min or so. Electron spectra measured with 113m In, 119m In and 144 Pr source are shown. (author)

  10. A comparison of methane emission measurements using eddy covariance and manual and automated chamber-based techniques in Tibetan Plateau alpine wetland

    International Nuclear Information System (INIS)

    Yu, Lingfei; Wang, Hao; Wang, Guangshuai; Song, Weimin; Huang, Yao; Li, Sheng-Gong; Liang, Naishen; Tang, Yanhong; He, Jin-Sheng

    2013-01-01

    Comparing of different CH 4 flux measurement techniques allows for the independent evaluation of the performance and reliability of those techniques. We compared three approaches, the traditional discrete Manual Static Chamber (MSC), Continuous Automated Chamber (CAC) and Eddy Covariance (EC) methods of measuring the CH 4 fluxes in an alpine wetland. We found a good agreement among the three methods in the seasonal CH 4 flux patterns, but the diurnal patterns from both the CAC and EC methods differed. While the diurnal CH 4 flux variation from the CAC method was positively correlated with the soil temperature, the diurnal variation from the EC method was closely correlated with the solar radiation and net CO 2 fluxes during the daytime but was correlated with the soil temperature at nighttime. The MSC method showed 25.3% and 7.6% greater CH 4 fluxes than the CAC and EC methods when measured between 09:00 h and 12:00 h, respectively. -- Highlights: •Chamber and eddy covariance methods showed similar seasonal CH 4 flux patterns. •Chamber and eddy covariance methods showed different diurnal CH 4 flux patterns. •Static chamber methods gave a higher magnitude of CH 4 flux. -- The chamber-based methods and the eddy covariance method showed similar seasonal CH 4 flux patterns, but the manual static chamber method resulted in a higher CH 4 flux measurement

  11. ABORt: Acknowledgement-Based Opportunistic Routing Protocol for High Data Rate Multichannel WSNs

    Directory of Open Access Journals (Sweden)

    Hamadoun Tall

    2017-10-01

    Full Text Available The ease of deployment and the auto-configuration capabilities of Wireless Sensor Networks (WSNs make them very attractive in different domains like environmental, home automation or heath care applications. The use of multichannel communications in WSNs helps to improve the overall performance of the network. However, in heavy traffic scenarios, routing protocols should be adapted to allow load balancing and to avoid losing data packets due to congestion and queue overflow. In this paper, we present an Acknowledgement-Based Opportunistic Routing (ABORt protocol designed for high data rate multichannel WSNs. It is a low overhead protocol that does not rely on synchronization for control traffic exchange during the operational phase of the network. ABORt is an opportunistic protocol that relies on link layer acknowledgements to disseminate routing metrics, which helps to reduce overhead. The performance of ABORt is evaluated using the Cooja simulator and the obtained results show that ABORt has a high packet delivery ratio with reduced packet end-to-end delay compared to two single channel routing protocols and two multichannel routing protocols that use number of hops and expected transmission count as routing metrics.

  12. Flat Engineered Multichannel Reflectors

    Directory of Open Access Journals (Sweden)

    V. S. Asadchy

    2017-09-01

    Full Text Available Recent advances in engineered gradient metasurfaces have enabled unprecedented opportunities for light manipulation using optically thin sheets, such as anomalous refraction, reflection, or focusing of an incident beam. Here, we introduce a concept of multichannel functional metasurfaces, which are able to control incoming and outgoing waves in a number of propagation directions simultaneously. In particular, we reveal a possibility to engineer multichannel reflectors. Under the assumption of reciprocity and energy conservation, we find that there exist three basic functionalities of such reflectors: specular, anomalous, and retroreflections. Multichannel response of a general flat reflector can be described by a combination of these functionalities. To demonstrate the potential of the introduced concept, we design and experimentally test three different multichannel reflectors: three- and five-channel retroreflectors and a three-channel power splitter. Furthermore, by extending the concept to reflectors supporting higher-order Floquet harmonics, we forecast the emergence of other multichannel flat devices, such as isolating mirrors, complex splitters, and multi-functional gratings.

  13. Flat Engineered Multichannel Reflectors

    Science.gov (United States)

    Asadchy, V. S.; Díaz-Rubio, A.; Tcvetkova, S. N.; Kwon, D.-H.; Elsakka, A.; Albooyeh, M.; Tretyakov, S. A.

    2017-07-01

    Recent advances in engineered gradient metasurfaces have enabled unprecedented opportunities for light manipulation using optically thin sheets, such as anomalous refraction, reflection, or focusing of an incident beam. Here, we introduce a concept of multichannel functional metasurfaces, which are able to control incoming and outgoing waves in a number of propagation directions simultaneously. In particular, we reveal a possibility to engineer multichannel reflectors. Under the assumption of reciprocity and energy conservation, we find that there exist three basic functionalities of such reflectors: specular, anomalous, and retroreflections. Multichannel response of a general flat reflector can be described by a combination of these functionalities. To demonstrate the potential of the introduced concept, we design and experimentally test three different multichannel reflectors: three- and five-channel retroreflectors and a three-channel power splitter. Furthermore, by extending the concept to reflectors supporting higher-order Floquet harmonics, we forecast the emergence of other multichannel flat devices, such as isolating mirrors, complex splitters, and multi-functional gratings.

  14. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  15. Semi-automated operation of Mars Climate Simulation chamber - MCSC modelled for biological experiments

    Science.gov (United States)

    Tarasashvili, M. V.; Sabashvili, Sh. A.; Tsereteli, S. L.; Aleksidze, N. D.; Dalakishvili, O.

    2017-10-01

    The Mars Climate Simulation Chamber (MCSC) (GEO PAT 12 522/01) is designed for the investigation of the possible past and present habitability of Mars, as well as for the solution of practical tasks necessary for the colonization and Terraformation of the Planet. There are specific tasks such as the experimental investigation of the biological parameters that allow many terrestrial organisms to adapt to the imitated Martian conditions: chemistry of the ground, atmosphere, temperature, radiation, etc. MCSC is set for the simulation of the conduction of various biological experiments, as well as the selection of extremophile microorganisms for the possible Settlement, Ecopoesis and/or Terraformation purposes and investigation of their physiological functions. For long-term purposes, it is possible to cultivate genetically modified organisms (e.g., plants) adapted to the Martian conditions for future Martian agriculture to sustain human Mars missions and permanent settlements. The size of the chamber allows preliminary testing of the functionality of space-station mini-models and personal protection devices such as space-suits, covering and building materials and other structures. The reliability of the experimental biotechnological materials can also be tested over a period of years. Complex and thorough research has been performed to acquire the most appropriate technical tools for the accurate engineering of the MCSC and precious programmed simulation of Martian environmental conditions. This paper describes the construction and technical details of the equipment of the MCSC, which allows its semi-automated, long-term operation.

  16. Small-sized reverberation chamber for the measurement of sound absorption

    International Nuclear Information System (INIS)

    Rey, R. del; Alba, J.; Bertó, L.; Gregori, A.

    2017-01-01

    This paper presents the design, construction, calibration and automation of a reverberation chamber for small samples. A balance has been sought between reducing sample size, to reduce the manufacturing costs of materials, and finding the appropriate volume of the chamber, to obtain reliable values at high and mid frequencies. The small-sized reverberation chamber, that was built, has a volume of 1.12 m3 and allows for the testing of samples of 0.3 m2. By using diffusers, to improve the diffusion degree, and automating measurements, we were able to improve the reliability of the results, thus reducing test errors. Several comparison studies of the measurements of the small-sized reverberation chamber and the standardised reverberation chamber are shown, and a good degree of adjustment can be seen between them, within the range of valid frequencies. This paper presents a small laboratory for comparing samples and making decisions before the manufacturing of larger sizes. [es

  17. Multi-channel data acquisition and processing system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Jin Ge; Yang Yanming

    1987-01-01

    A multi-channel data acquisition and processing system for moessbauer spectroscopy is described, which consists of an intelligent interface and a BC3-80 microcomputer. The system has eight data channels, each channel contains a counting circuit and a memory. A Z80-CPU is used as a main unit for control and access. The microcomputer is used for real-time displaying spectrum, saving the data to disk, printing data and data processing. The system is applicable to a high counting rate multi-wire proportional chamber. It can increase greatly the counting rate for measuring moessbauer spectrum. The signals of each wire in the chamber go through a corresponding amplifier and a differential discriminator and are recorded by a corresponding data channel, the data of each channel is added by the microcomputer. In addition, two channels can be used to measure an absorption and a scattering spectrum at the same time and the internal and the surface information of the sample are obtained simultaneously

  18. Multichannel waveform display system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.

    1989-01-01

    For any multichannel data acquisition system, a multichannel paper chart recorder undoubtedly forms an essential part of the system. When deployed on-line, it instantaneously provides, for visual inspection, hard copies of the signal waveforms on common time base at any desired sensitivity and time resolution. Within the country, only a small range of these strip chart recorder s is available, and under stringent specifications imported recorders are often procured. The cost of such recorders may range from 1 to 5 lakhs of rupees in foreign exchange. A system to provide on the oscilloscope a steady display of multichannel waveforms, refreshed from the digital data stored in the memory is developed. The merits and demerits of the display system are compared with that built around a conventional paper chart recorder. Various illustrations of multichannel seismic event data acquired at Gauribidanur seismic array station are also presented. (author). 2 figs

  19. Portable automation of static chamber sample collection for quantifying soil gas flux

    Science.gov (United States)

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  20. Gas chromatography vs. quantum cascade laser-based N2O flux measurements using a novel chamber design

    DEFF Research Database (Denmark)

    Bruemmer, Christian; Lyshede, Bjarne; Lempio, Dirk

    2017-01-01

    automated chamber system against a conventional gas chromatography (GC) approach using the same chambers plus an automated gas sampling unit with septum capped vials and subsequent laboratory GC analysis. Through its high precision and time resolution, data of the QCL system were used for quantifying...

  1. Automatic pickup of arrival time of channel wave based on multi-channel constraints

    Science.gov (United States)

    Wang, Bao-Li

    2018-03-01

    Accurately detecting the arrival time of a channel wave in a coal seam is very important for in-seam seismic data processing. The arrival time greatly affects the accuracy of the channel wave inversion and the computed tomography (CT) result. However, because the signal-to-noise ratio of in-seam seismic data is reduced by the long wavelength and strong frequency dispersion, accurately timing the arrival of channel waves is extremely difficult. For this purpose, we propose a method that automatically picks up the arrival time of channel waves based on multi-channel constraints. We first estimate the Jaccard similarity coefficient of two ray paths, then apply it as a weight coefficient for stacking the multichannel dispersion spectra. The reasonableness and effectiveness of the proposed method is verified in an actual data application. Most importantly, the method increases the degree of automation and the pickup precision of the channel-wave arrival time.

  2. Multichannel interictal spike activity detection using time-frequency entropy measure.

    Science.gov (United States)

    Thanaraj, Palani; Parvathavarthini, B

    2017-06-01

    Localization of interictal spikes is an important clinical step in the pre-surgical assessment of pharmacoresistant epileptic patients. The manual selection of interictal spike periods is cumbersome and involves a considerable amount of analysis workload for the physician. The primary focus of this paper is to automate the detection of interictal spikes for clinical applications in epilepsy localization. The epilepsy localization procedure involves detection of spikes in a multichannel EEG epoch. Therefore, a multichannel Time-Frequency (T-F) entropy measure is proposed to extract features related to the interictal spike activity. Least squares support vector machine is used to train the proposed feature to classify the EEG epochs as either normal or interictal spike period. The proposed T-F entropy measure, when validated with epilepsy dataset of 15 patients, shows an interictal spike classification accuracy of 91.20%, sensitivity of 100% and specificity of 84.23%. Moreover, the area under the curve of Receiver Operating Characteristics plot of 0.9339 shows the superior classification performance of the proposed T-F entropy measure. The results of this paper show a good spike detection accuracy without any prior information about the spike morphology.

  3. Automated complex spectra processing of actinide α-radiation

    International Nuclear Information System (INIS)

    Anichenkov, S.V.; Popov, Yu.S.; Tselishchev, I.V.; Mishenev, V.B.; Timofeev, G.A.

    1989-01-01

    Earlier described algorithms of automated processing of complex α - spectra of actinides with the use of Ehlektronika D3-28 computer line, connected with ICA-070 multichannel amplitude pulse analyzer, were realized. The developed program enables to calculated peak intensity and the relative isotope content, to conduct energy calibration of spectra, to calculate peak center of gravity and energy resolution, to perform integral counting in particular part of the spectrum. Error of the method of automated processing depens on the degree of spectrum complication and lies within the limits of 1-12%. 8 refs.; 4 figs.; 2 tabs

  4. Virtual Microphones for Multichannel Audio Resynthesis

    Directory of Open Access Journals (Sweden)

    Athanasios Mouchtaris

    2003-09-01

    Full Text Available Multichannel audio offers significant advantages for music reproduction, including the ability to provide better localization and envelopment, as well as reduced imaging distortion. On the other hand, multichannel audio is a demanding media type in terms of transmission requirements. Often, bandwidth limitations prohibit transmission of multiple audio channels. In such cases, an alternative is to transmit only one or two reference channels and recreate the rest of the channels at the receiving end. Here, we propose a system capable of synthesizing the required signals from a smaller set of signals recorded in a particular venue. These synthesized “virtual” microphone signals can be used to produce multichannel recordings that accurately capture the acoustics of that venue. Applications of the proposed system include transmission of multichannel audio over the current Internet infrastructure and, as an extension of the methods proposed here, remastering existing monophonic and stereophonic recordings for multichannel rendering.

  5. Essays on multichannel customer management

    NARCIS (Netherlands)

    Konus, U.

    2010-01-01

    The main goal of this dissertation is to gain a greater understanding of multichannel customer behavior and how firms can manage their multichannel marketing activities. The first study reveals that three customer segments can be identified based on their orientation towards using multiple channels

  6. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  7. Automated installation for atomic emission determination of gold, silver and platinum group metals

    International Nuclear Information System (INIS)

    Zayakina, S.B.; Anoshin, G.N.; Gerasimov, P.A.; Smirnov, A.V.

    1999-01-01

    An automated installation for the direct atomic emission determination of silver, gold and platinum-group metals (Ru) in geological and geochemical materials with software for automated data acquisition and handling is designed and developed. The installation consists of a DFS-458 diffraction spectrograph, a MAES-10 multichannel analyzer of emission spectra, and a dual-jet plasmatron. A library of spectral lines of almost all elements excited in the dual-jet plasmatron is complied [ru

  8. Automated system for calibration and control of the CHSPP-800 multichannel γ detector parameters

    International Nuclear Information System (INIS)

    Avvakumov, N.A.; Belikov, N.I.; Goncharenko, Yu.M.

    1987-01-01

    An automated system for adjustment, calibration and control of total absorption Cherenkov spectrometer is described. The system comprises a mechanical platform, capable of moving in two mutually perpendicular directions; movement detectors and limit switches; power unit, automation unit with remote control board. The automated system can operate both in manual control regime with coordinate control by a digital indicator, and in operation regime with computer according to special programs. The platform mounting accuracy is ± 0.1 mm. Application of the automated system has increased the rate of the course of the counter adjustment works 3-5 times

  9. Modeling High-Dimensional Multichannel Brain Signals

    KAUST Repository

    Hu, Lechuan; Fortin, Norbert J.; Ombao, Hernando

    2017-01-01

    aspects: first, there are major statistical and computational challenges for modeling and analyzing high-dimensional multichannel brain signals; second, there is no set of universally agreed measures for characterizing connectivity. To model multichannel

  10. Multichannel analog temperature sensing system

    International Nuclear Information System (INIS)

    Gribble, R.

    1985-08-01

    A multichannel system that protects the numerous and costly water-cooled magnet coils on the translation section of the FRX-C/T magnetic fusion experiment is described. The system comprises a thermistor for each coil, a constant current circuit for each thermistor, and a multichannel analog-to-digital converter interfaced to the computer

  11. Processing and Analysis of Multichannel Extracellular Neuronal Signals: State-of-the-art and Challenges

    Directory of Open Access Journals (Sweden)

    Mufti eMahmud

    2016-06-01

    Full Text Available In recent years multichannel neuronal signal acquisition systems have allowed scientists to focus on research questions which were otherwise impossible. They act as a powerful means to study brain (dysfunctions in in-vivo and in in-vitro animal models. Typically, each session of electrophysiological experiments with multichannel data acquisition systems generate large amount of raw data. For example, a 128 channel signal acquisition system with 16 bits A/D conversion and 20 kHz sampling rate will generate approximately 17 GB data per hour (uncompressed. This poses an important and challenging problem of inferring conclusions from the large amounts of acquired data. Thus, automated signal processing and analysis tools are becoming a key component in neuroscience research, facilitating extraction of relevant information from neuronal recordings in a reasonable time. The purpose of this review is to introduce the reader to the current state-of-the-art of open-source packages for (semiautomated processing and analysis of multichannel extracellular neuronal signals (i.e., neuronal spikes, local field potentials, electroencephalogram, etc., and the existing Neuroinformatics infrastructure for tool and data sharing. The review is concluded by pinpointing some major challenges that are to be faced, which include the development of novel benchmarking techniques, cloud-based distributed processing and analysis tools, as well as defining novel means to share and standardize data.

  12. Radiation-hard ceramic Resistive Plate Chambers for forward TOF and T0 systems

    Energy Technology Data Exchange (ETDEWEB)

    Akindinov, A., E-mail: Alexander.Akindinov@cern.ch [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Dreyer, J.; Fan, X.; Kämpfer, B. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kiselev, S. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Kotte, R.; Garcia, A. Laso [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Malkevich, D. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Naumann, L. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Nedosekin, A.; Plotnikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Stach, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Sultanov, R.; Voloshin, K. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation)

    2017-02-11

    Resistive Plate Chambers with ceramic electrodes are the main candidates for a use in precise multi-channel timing systems operating in high-radiation conditions. We report the latest R&D results on these detectors aimed to meet the requirements of the forward T0 counter at the CBM experiment. RPC design, gas mixture, limits on the bulk resistivity of ceramic electrodes, efficiency, time resolution, counting rate capabilities and ageing test results are presented.

  13. Multichannel analyzer embedded in FPGA

    International Nuclear Information System (INIS)

    Garcia D, A.; Hernandez D, V. M.; Vega C, H. R.; Ordaz G, O. O.; Bravo M, I.

    2017-10-01

    Ionizing radiation has different applications, so it is a very significant and useful tool, which in turn can be dangerous for living beings if they are exposed to uncontrolled doses. However, due to its characteristics, it cannot be perceived by any of the senses of the human being, so that in order to know the presence of it, radiation detectors and additional devices are required to quantify and classify it. A multichannel analyzer is responsible for separating the different pulse heights that are generated in the detectors, in a certain number of channels; according to the number of bits of the analog to digital converter. The objective of the work was to design and implement a multichannel analyzer and its associated virtual instrument, for nuclear spectrometry. The components of the multichannel analyzer were created in VHDL hardware description language and packaged in the Xilinx Vivado design suite, making use of resources such as the ARM processing core that the System on Chip Zynq contains and the virtual instrument was developed on the LabView programming graphics platform. The first phase was to design the hardware architecture to be embedded in the FPGA and for the internal control of the multichannel analyzer the application was generated for the ARM processor in C language. For the second phase, the virtual instrument was developed for the management, control and visualization of the results. The data obtained as a result of the development of the system were observed graphically in a histogram showing the spectrum measured. The design of the multichannel analyzer embedded in FPGA was tested with two different radiation detection systems (hyper-pure germanium and scintillation) which allowed determining that the spectra obtained are similar in comparison with the commercial multichannel analyzers. (Author)

  14. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We

  15. Organization of bubble chamber image processing

    International Nuclear Information System (INIS)

    Gritsaenko, I.A.; Petrovykh, L.P.; Petrovykh, Yu.L.; Fenyuk, A.B.

    1985-01-01

    A programme of bubble chamber image processing is described. The programme is written in FORTRAN, it is developed for the DEC-10 computer and is designed for operation of semi-automation processing-measurement projects PUOS-2 and PUOS-4. Fornalization of the image processing permits to use it for different physical experiments

  16. Multichannel analyzer type CMA-3

    International Nuclear Information System (INIS)

    Czermak, A.; Jablonski, J.; Ostrowicz, A.

    1978-01-01

    Multichannel analyzer CMA-3 is designed for two-parametric analysis with operator controlled logical windows. It is implemented in CAMAC standard. A single crate contains all required modules and is controlled by the PDP-11/10 minicomputer. Configuration of CMA-3 is shown. CMA-3 is the next version of the multichannel analyzer described in report No 958/E-8. (author)

  17. Automated correction on X-rays calibration using transmission chamber and LabVIEWTM

    International Nuclear Information System (INIS)

    Betti, Flavio; Potiens, Maria da Penha Albuquerque

    2009-01-01

    Uncertainties during prolonged exposure times on X-rays calibration procedures at the Instruments Calibration facilities at IPEN may suffer from efficiency (and therefore intensity) variations on the industrial X-Ray generator used. Using a transmission chamber as an online reference chamber during the whole irradiation process is proposed in order to compensate for such error source. Also temperature (and pressure) fluctuations may arise from the performance limited calibration room air conditioning system. As an open ionization chamber, that monitor chamber does require calculation of a correction factor due to the temperature and pressure effects on air density. Sending and processing data from all related instruments (electrometer, thermometer and barometer) can be more easily achieved by interfacing them to a host computer running an especially developed algorithm using LabVIEW TM environment which will not only apply the proper correction factors during runtime, but also determine the exact length of time to reach a desired condition, which can be: time period, charge collected, or air kerma, based on the previous calibration of the whole system using a reference chamber traceable to primary standard dosimetry laboratories. When performing such calibration, two temperature sensors (secondary standard thermistors) are simultaneously used, one for the transmission chamber, and other for the reference chamber. As the substitution method is used during actual customer's calibration, the readings from the second thermistor can also be used when desired for further corrections. Use of LabVIEW TM programming language allowed for a shorter development time, and it is also extremely convenient to make things easier when improvements and modifications are called for. (author)

  18. Multi-channel mechanical test machine for HANARO (I)

    International Nuclear Information System (INIS)

    Song, M. S.; Choi, Y.; Cho, M. S.; Kim, B. G.; Kang, Y. H.

    2004-01-01

    Design and fabrication of multi-channel mechanical test machine is useful and important for the study of in-pile test of nuclear materials in HANARO. The dimension and shape of the multi-channel mechanical test machine should be fixed to a test reactor and their objectives. KAERI successfully developed a non-instrumented multi-channel mechanical test machine for material irradiation tests in a domestic research reactor, HANARO. This results in strongly stimulating and accelerating irradiation tests of materials in domestic industry and research fields with HANARO. Although various types of in-pile creep capsule were made for well installation in each test reactor, there is no in-pile creep multi-channel mechanical test machine for HANARO. Hence, the objectives of this study are to fabricate and test a multi-channel mechanical test machine of HANARO

  19. Automated filtering of common-mode artifacts in multichannel physiological recordings.

    Science.gov (United States)

    Kelly, John W; Siewiorek, Daniel P; Smailagic, Asim; Wang, Wei

    2013-10-01

    The removal of spatially correlated noise is an important step in processing multichannel recordings. Here, a technique termed the adaptive common average reference (ACAR) is presented as an effective and simple method for removing this noise. The ACAR is based on a combination of the well-known common average reference (CAR) and an adaptive noise canceling (ANC) filter. In a convergent process, the CAR provides a reference to an ANC filter, which in turn provides feedback to enhance the CAR. This method was effective on both simulated and real data, outperforming the standard CAR when the amplitude or polarity of the noise changes across channels. In many cases, the ACAR even outperformed independent component analysis. On 16 channels of simulated data, the ACAR was able to attenuate up to approximately 290 dB of noise and could improve signal quality if the original SNR was as high as 5 dB. With an original SNR of 0 dB, the ACAR improved signal quality with only two data channels and performance improved as the number of channels increased. It also performed well under many different conditions for the structure of the noise and signals. Analysis of contaminated electrocorticographic recordings further showed the effectiveness of the ACAR.

  20. Construction of the Cleo III drift chamber

    International Nuclear Information System (INIS)

    Csorna, S.; Marka, S.; Dickson, M.; Dombrowski, S. von; Peterson, D.; Thies, P.; Glenn, S.; Thorndike, E.H.; Kravchenko, I.

    1998-01-01

    The CLEO III group is constructing a new chamber to be installed as part of the staged luminosity upgrade program at the Cornell electron storage ring and compatible with the interaction region optics. Although having less radial extent than the current CLEO II tracking system, CLEO III will have equivalent momentum resolution because of material reduction in the drift chamber inner skin and gas. The thin inner skin requires special attention to the end-plate motion due to wire creep. During stringing, use of a robot will fully automate the wire handling on the upper end. (author)

  1. Automated target recognition and tracking using an optical pattern recognition neural network

    Science.gov (United States)

    Chao, Tien-Hsin

    1991-01-01

    The on-going development of an automatic target recognition and tracking system at the Jet Propulsion Laboratory is presented. This system is an optical pattern recognition neural network (OPRNN) that is an integration of an innovative optical parallel processor and a feature extraction based neural net training algorithm. The parallel optical processor provides high speed and vast parallelism as well as full shift invariance. The neural network algorithm enables simultaneous discrimination of multiple noisy targets in spite of their scales, rotations, perspectives, and various deformations. This fully developed OPRNN system can be effectively utilized for the automated spacecraft recognition and tracking that will lead to success in the Automated Rendezvous and Capture (AR&C) of the unmanned Cargo Transfer Vehicle (CTV). One of the most powerful optical parallel processors for automatic target recognition is the multichannel correlator. With the inherent advantages of parallel processing capability and shift invariance, multiple objects can be simultaneously recognized and tracked using this multichannel correlator. This target tracking capability can be greatly enhanced by utilizing a powerful feature extraction based neural network training algorithm such as the neocognitron. The OPRNN, currently under investigation at JPL, is constructed with an optical multichannel correlator where holographic filters have been prepared using the neocognitron training algorithm. The computation speed of the neocognitron-type OPRNN is up to 10(exp 14) analog connections/sec that enabling the OPRNN to outperform its state-of-the-art electronics counterpart by at least two orders of magnitude.

  2. Neural network approach in multichannel auditory event-related potential analysis.

    Science.gov (United States)

    Wu, F Y; Slater, J D; Ramsay, R E

    1994-04-01

    Even though there are presently no clearly defined criteria for the assessment of P300 event-related potential (ERP) abnormality, it is strongly indicated through statistical analysis that such criteria exist for classifying control subjects and patients with diseases resulting in neuropsychological impairment such as multiple sclerosis (MS). We have demonstrated the feasibility of artificial neural network (ANN) methods in classifying ERP waveforms measured at a single channel (Cz) from control subjects and MS patients. In this paper, we report the results of multichannel ERP analysis and a modified network analysis methodology to enhance automation of the classification rule extraction process. The proposed methodology significantly reduces the work of statistical analysis. It also helps to standardize the criteria of P300 ERP assessment and facilitate the computer-aided analysis on neuropsychological functions.

  3. Use of the MCL dialog language for autonomous multi-channel analyzer automation

    International Nuclear Information System (INIS)

    Gyunter, Z.; Lebner, M.; Mikhaehlis, B.; Shvenkner, V.; Shul'tts, K.-Kh.

    1985-01-01

    The structure and software of a time-of-flight multichannel analyzer are considered. The analyzer is a subsystem of the measuring module of the SPN-1 polarized neutron spectrometer used in experiments at the IBR-2 reactor. The analyzer operates having several structures differing from one another by a timing coder. The MCL (MULTI-CONTROL-LANGUAGE) system is developed for control of the spectrometer. The system ensures the computer-user conversation and interfacing the computer and the experimental equipment. The MCL language is similar to that of the BASIC or the BAMBI. It has modular structure. The language interpreter and operating system have about 2 kbyte memory. The considered analyser is successfully used already during 6 months. The number of detector inputs of the analyser increased. Expenditures for alternations of programs are negligible due to modular structure of the system. Realization of new commads does not require comprehensive knowledge of the MCL language

  4. The Bateman method for multichannel scattering theory

    International Nuclear Information System (INIS)

    Kim, Y. E.; Kim, Y. J.; Zubarev, A. L.

    1997-01-01

    Accuracy and convergence of the Bateman method are investigated for calculating the transition amplitude in multichannel scattering theory. This approximation method is applied to the calculation of elastic amplitude. The calculated results are remarkably accurate compared with those of exactly solvable multichannel model

  5. Process development for automated solar-cell and module production. Task 4. Automated array assembly. Quarterly report No. 3

    Energy Technology Data Exchange (ETDEWEB)

    Hagerty, J. J.; Gifford, M.

    1981-04-15

    The Automated Lamination Station is mechanically complete and is currently undergoing final wiring. The high current driver and isolator boards have been completed and installed, and the main interface board is under construction. The automated vacuum chamber has had a minor redesign to increase stiffness and improve the cover open/close mechanism. Design of the Final Assembly Station has been completed and construction is underway.

  6. Multichannel strategy - the dominant approach in modern retailing

    Directory of Open Access Journals (Sweden)

    Stojković Dragan

    2016-01-01

    Full Text Available The purpose of this paper is to thoroughly analyse the concept of multichannel strategy, focussing on retail, to enable the academic community and marketers to better understand its advantages and disadvantages. This paper presents a comprehensive literature review and financial data analysis. The authors have analysed the financial data of 88 retail companies in the 2007 to 2014 period, and have proven that the importance of multichannel strategy has grown with the emergence of e-commerce. The main hypothesis is that the multichannel concept dominates modern marketing channels because it is widely accepted and provides superior financial performance. Multichannel retailing is definitely a winning concept, if adequately implemented. However, wrongly implemented it can negatively influence business performance.

  7. Dense Clustered Multi-Channel Wireless Sensor Cloud

    Directory of Open Access Journals (Sweden)

    Sivaramakrishnan Sivakumar

    2015-08-01

    Full Text Available Dense Wireless Sensor Network Clouds have an inherent issue of latency and packet drops with regards to data collection. Though there is extensive literature that tries to address these issues through either scheduling, channel contention or a combination of the two, the problem still largely exists. In this paper, a Clustered Multi-Channel Scheduling Protocol (CMSP is designed that creates a Voronoi partition of a dense network. Each partition is assigned a channel, and a scheduling scheme is adopted to collect data within the Voronoi partitions. This scheme collects data from the partitions concurrently and then passes it to the base station. CMSP is compared using simulation with other multi-channel protocols like Tree-based Multi-Channel, Multi-Channel MAC and Multi-frequency Media Access Control for wireless sensor networks. Results indicate CMSP has higher throughput and data delivery ratio at a lower power consumption due to network partitioning and hierarchical scheduling that minimizes load on the network.

  8. Environmental gamma radiation monitoring system with a large volume air ionization chamber

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, C.; Witzani, J.

    1986-01-01

    An improved environmental monitoring system has been designed and tested consisting of an ionization chamber with 120 l sensitive volume, operated at atmospheric pressure, and a commercial electrometer amplifier with digital voltmeter. The system is controlled by a desk calculator with printer for automated operation and calculation of dose and doserate. The ionization chamber provides superior dosimetric performance as compared to usual GM-counters and high pressure chambers. The system has been field-tested during the 'European Intercomparison Programme for Environmental Monitoring Instruments' organized by the Commission of the European Communities. (Author)

  9. Designing a Multichannel Map Service Concept

    Directory of Open Access Journals (Sweden)

    Hanna-Marika Halkosaari

    2013-01-01

    Full Text Available This paper introduces a user-centered design process for developing a multichannel map service. The aim of the service is to provide hikers with interactive maps through several channels. In a multichannel map service, the same spatial information is available through various channels, such as printed maps, Web maps, mobile maps, and other interactive media. When properly networked, the channels share a uniform identity so that the user experiences the different channels as a part of a single map service. The traditional methods of user-centered design, such as design probes, personas, and scenarios, proved useful even in the emerging field of developing multichannel map services. The findings emphasize the need to involve users and multidisciplinary teams in the conceptual phases of designing complex services aimed at serving various kinds of users.

  10. Evaluation of multichannel reproduced sound

    DEFF Research Database (Denmark)

    Choisel, Sylvain; Wickelmaier, Florian Maria

    2007-01-01

    A study was conducted with the goal of quantifying auditory attributes which underlie listener preference for multichannel reproduced sound. Short musical excerpts were presented in mono, stereo and several multichannel formats to a panel of forty selected listeners. Scaling of auditory attributes......, as well as overall preference, was based on consistency tests of binary paired-comparison judgments and on modeling the choice frequencies using probabilistic choice models. As a result, the preferences of non-expert listeners could be measured reliably at a ratio scale level. Principal components derived...

  11. Automated Filtering of Common Mode Artifacts in Multi-Channel Physiological Recordings

    Science.gov (United States)

    Kelly, John W.; Siewiorek, Daniel P.; Smailagic, Asim; Wang, Wei

    2014-01-01

    The removal of spatially correlated noise is an important step in processing multi-channel recordings. Here, a technique termed the adaptive common average reference (ACAR) is presented as an effective and simple method for removing this noise. The ACAR is based on a combination of the well-known common average reference (CAR) and an adaptive noise canceling (ANC) filter. In a convergent process, the CAR provides a reference to an ANC filter, which in turn provides feedback to enhance the CAR. This method was effective on both simulated and real data, outperforming the standard CAR when the amplitude or polarity of the noise changes across channels. In many cases the ACAR even outperformed independent component analysis (ICA). On 16 channels of simulated data the ACAR was able to attenuate up to approximately 290 dB of noise and could improve signal quality if the original SNR was as high as 5 dB. With an original SNR of 0 dB, the ACAR improved signal quality with only two data channels and performance improved as the number of channels increased. It also performed well under many different conditions for the structure of the noise and signals. Analysis of contaminated electrocorticographic (ECoG) recordings further showed the effectiveness of the ACAR. PMID:23708770

  12. Multi-channel data acquisition system for CT

    International Nuclear Information System (INIS)

    Cao Fuqiang; He Bin; Liu Guohua; Xu Minjian

    2009-01-01

    The architecture design and realization of a data acquisition system for multi-channel CT is described. The article introduces the conversion of analog signal to digital signal, the data cache and transmission. This data acquisition system can be widely used in the system which requires the multi-channel, weak current signal detection. (authors)

  13. Multichannel photocells for image converters with color separation

    Energy Technology Data Exchange (ETDEWEB)

    Denisova, E. A.; Uzdovskii, V. V., E-mail: uzdovskii@list.ru; Khainovskii, V. I. [Moscow Institute of Electronic Technology (Russian Federation)

    2011-12-15

    The results of a study of photoelectric processes in photosensitive structures based on a multichannel vertically integrated p-n junction are presented. Optical radiation absorption in the space-charge region of a multichannel vertically integrated structure is studied.

  14. Computer-based multi-channel analyzer based on internet

    International Nuclear Information System (INIS)

    Zhou Xinzhi; Ning Jiaoxian

    2001-01-01

    Combined the technology of Internet with computer-based multi-channel analyzer, a new kind of computer-based multi-channel analyzer system which is based on browser is presented. Its framework and principle as well as its implementation are discussed

  15. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  16. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  17. Development and implementation of own software for dosimetry multichannel film

    International Nuclear Information System (INIS)

    Jimenez Feltstrom, D.; Reyes Garcia, R.; Luis Simon, F. J.; Carrasco Herrera, M.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-01-01

    The objective of this work is to develop its own software for multichannel film dosimetry Radiochromic EBT2. Compare the results obtained with its use in multichannel and single-channel dosimetry. Check that the multi-channel dosimetry eliminates much of the artifacts caused by dirt, fingerprints, scratches, etc. Radiochromic in film and scanner devices. (Author)

  18. 三开门自动温室气体测定箱的应用效果%Effect of greenhouse gas measurement of three-side-open automated chamber

    Institute of Scientific and Technical Information of China (English)

    万运帆; 李玉娥; 刘运通; 高清竹; 秦晓波; 刘硕; 马欣

    2011-01-01

    为了降低农田自动温室气体测定箱在观测过程中对作物生长环境及作物生长的干扰,本研究在玉米大田环境条件下比较了一种新型的三开门 自动温室气体测定箱与传统单开门自动温室气体测定箱对环境空气温湿度、土壤温度与水分、玉米生长以及温室气体排放的影响.结果表明:三开门温室气体测定箱能显著减小与大田环境条件下的空气温度、湿度及土壤温度的差异;相对于单开门箱,三开门箱在箱体打开及关闭条件下气温平均低0.90和0.74℃,空气湿度平均增加1.36%和降低5.69%:在玉米小喇叭口期前土壤温度约降低2℃,小喇叭口期后差异不显著;对土壤水分的影响在玉米苗期有一定的作用,但差异小显著;三开 门箱相对于单开门箱能显著降低箱体对作物生长的影响,还能降低CO2平均通量值6.85%及N2O的平均通量值3.68%,而对CH4平均通量值基本无影响.因此,三开门箱相对于传统单开门自动温室气体测定箱能显著减小测定箱时观测环境及作物生长的干扰,应用这种箱体观测能更好地反映田间温室气体排放状况.%In order to decrease the disturbance of automatic chamber on crop growth and its growing environment during greenhouse gases measurement, the effect experiment of a three-side-open automated chamber on greenhouse gases measurement in maize field was conducted in compare with traditional open-at-top chamber. The experiment was to test the three-side-open chamber's character on ambient temperature, ambient relative humidity, soil temperature, soil moisture, crop growth and greenhouse gases emission. Results showed that in compare with traditional open-at-top chamber, the three-side-open chamber can significantly decrease the influence of chamber on ambient temperature, ambient relative humidity and soil temperature. It can decrease ambient temperature by 0.90℃and increase air relative humidity by 1

  19. Order fulfillment and logistics considerations for multichannel retailers

    NARCIS (Netherlands)

    Roodbergen, Kees Jan; Kolman, Inger B.; Zijm, W.H.M.; Klumpp, M.; Clausen, V.; Ten Hompel, M.

    2016-01-01

    This paper addresses the challenge of making multichannel decisions for order fulfillment and logistics. We present a framework for multichannel strategies consisting of seven elements. Some channel decisions are part of the marketing mix, with the ultimate choice left to the customer. Other channel

  20. Multichannel, sequential or combined X-ray spectrometry

    International Nuclear Information System (INIS)

    Florestan, J.

    1979-01-01

    X-ray spectrometer qualities and defects are evaluated for sequential and multichannel categories. Multichannel X-ray spectrometer has time-coherency advantage and its results could be more reproducible; on the other hand some spatial incoherency limits low percentage and traces applications, specially when backgrounds are very variable. In this last case, sequential X-ray spectrometer would find again great usefulness [fr

  1. Considerations on automation of coating machines

    Science.gov (United States)

    Tilsch, Markus K.; O'Donnell, Michael S.

    2015-04-01

    Most deposition chambers sold into the optical coating market today are outfitted with an automated control system. We surveyed several of the larger equipment providers, and nine of them responded with information about their hardware architecture, data logging, level of automation, error handling, user interface, and interfacing options. In this paper, we present a summary of the results of the survey and describe commonalities and differences together with some considerations of tradeoffs, such as between capability for high customization and simplicity of operation.

  2. Calculated characteristics of multichannel photoelectron multipliers

    International Nuclear Information System (INIS)

    Vasil'chenko, V.G.; Dajkovskij, A.G.; Milova, N.V.; Rakhmatov, V.E.; Rykalin, V.I.

    1990-01-01

    Structural features and main calculated characteristics of some modifications of position-sensitive two-coordinate multichannel photoelectron multipliers (PEM) with plate-type multiplying systems are described. The presented PEM structures are free from direct optical and ion feedbacks, provide coordinate resolution ≅ 1 mm with efficiency of photoelectron detection ≅ 90%. Capabilities for using silicon field-effect photocathodes, providing electron extraction into vacuum, as well as prospects of using multichannel multiplying systems for readout of the data from solid detectors are considered

  3. The Buywell Way: seven essential practices of a highly successful multi-channel e-tailer

    Directory of Open Access Journals (Sweden)

    Mary Tate

    2005-05-01

    Full Text Available After the dot-com bust there is considerable evidence that multi-channel retailers are more successful than purely on-line retailers. Multi-channel retailing is becoming mainstream and considerable research exists on successful multi-channel strategies. Despite this, some organisations are having more success than others with their multi-channel approach. We talked to the management of one of Australasia’s most successful multi-channel apparel and home-ware retailers about the theory and practice of multi-channel retailing, with the aim of building on existing theory in multi-channel e-commerce.

  4. Highly Efficient Compression Algorithms for Multichannel EEG.

    Science.gov (United States)

    Shaw, Laxmi; Rahman, Daleef; Routray, Aurobinda

    2018-05-01

    The difficulty associated with processing and understanding the high dimensionality of electroencephalogram (EEG) data requires developing efficient and robust compression algorithms. In this paper, different lossless compression techniques of single and multichannel EEG data, including Huffman coding, arithmetic coding, Markov predictor, linear predictor, context-based error modeling, multivariate autoregression (MVAR), and a low complexity bivariate model have been examined and their performances have been compared. Furthermore, a high compression algorithm named general MVAR and a modified context-based error modeling for multichannel EEG have been proposed. The resulting compression algorithm produces a higher relative compression ratio of 70.64% on average compared with the existing methods, and in some cases, it goes up to 83.06%. The proposed methods are designed to compress a large amount of multichannel EEG data efficiently so that the data storage and transmission bandwidth can be effectively used. These methods have been validated using several experimental multichannel EEG recordings of different subjects and publicly available standard databases. The satisfactory parametric measures of these methods, namely percent-root-mean square distortion, peak signal-to-noise ratio, root-mean-square error, and cross correlation, show their superiority over the state-of-the-art compression methods.

  5. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  6. Automated Long-Term Monitoring of Parallel Microfluidic Operations Applying a Machine Vision-Assisted Positioning Method

    Science.gov (United States)

    Yip, Hon Ming; Li, John C. S.; Cui, Xin; Gao, Qiannan; Leung, Chi Chiu

    2014-01-01

    As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities. PMID:25133248

  7. Automated long-term monitoring of parallel microfluidic operations applying a machine vision-assisted positioning method.

    Science.gov (United States)

    Yip, Hon Ming; Li, John C S; Xie, Kai; Cui, Xin; Prasad, Agrim; Gao, Qiannan; Leung, Chi Chiu; Lam, Raymond H W

    2014-01-01

    As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities.

  8. Automated Long-Term Monitoring of Parallel Microfluidic Operations Applying a Machine Vision-Assisted Positioning Method

    Directory of Open Access Journals (Sweden)

    Hon Ming Yip

    2014-01-01

    Full Text Available As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities.

  9. Multichannel compressive sensing MRI using noiselet encoding.

    Directory of Open Access Journals (Sweden)

    Kamlesh Pawar

    Full Text Available The incoherence between measurement and sparsifying transform matrices and the restricted isometry property (RIP of measurement matrix are two of the key factors in determining the performance of compressive sensing (CS. In CS-MRI, the randomly under-sampled Fourier matrix is used as the measurement matrix and the wavelet transform is usually used as sparsifying transform matrix. However, the incoherence between the randomly under-sampled Fourier matrix and the wavelet matrix is not optimal, which can deteriorate the performance of CS-MRI. Using the mathematical result that noiselets are maximally incoherent with wavelets, this paper introduces the noiselet unitary bases as the measurement matrix to improve the incoherence and RIP in CS-MRI. Based on an empirical RIP analysis that compares the multichannel noiselet and multichannel Fourier measurement matrices in CS-MRI, we propose a multichannel compressive sensing (MCS framework to take the advantage of multichannel data acquisition used in MRI scanners. Simulations are presented in the MCS framework to compare the performance of noiselet encoding reconstructions and Fourier encoding reconstructions at different acceleration factors. The comparisons indicate that multichannel noiselet measurement matrix has better RIP than that of its Fourier counterpart, and that noiselet encoded MCS-MRI outperforms Fourier encoded MCS-MRI in preserving image resolution and can achieve higher acceleration factors. To demonstrate the feasibility of the proposed noiselet encoding scheme, a pulse sequences with tailored spatially selective RF excitation pulses was designed and implemented on a 3T scanner to acquire the data in the noiselet domain from a phantom and a human brain. The results indicate that noislet encoding preserves image resolution better than Fouirer encoding.

  10. Essays on Online and Multi-Channel Marketing

    OpenAIRE

    Zhang, Lingling

    2016-01-01

    Firms increasingly adopt online and multi-channel marketing strategies to reach and persuade consumers. Therefore, designing an effective marketing mix is critical to their success. The aim of my dissertation is to understand the strategy behind firms’ channel choices and assess marketing effectiveness. It consists of three large-scale empirical studies examining several important aspects of online and multi-channel marketing. My first essay focuses on the business-to-business (B2B) inte...

  11. Multichannel biomedical time series clustering via hierarchical probabilistic latent semantic analysis.

    Science.gov (United States)

    Wang, Jin; Sun, Xiangping; Nahavandi, Saeid; Kouzani, Abbas; Wu, Yuchuan; She, Mary

    2014-11-01

    Biomedical time series clustering that automatically groups a collection of time series according to their internal similarity is of importance for medical record management and inspection such as bio-signals archiving and retrieval. In this paper, a novel framework that automatically groups a set of unlabelled multichannel biomedical time series according to their internal structural similarity is proposed. Specifically, we treat a multichannel biomedical time series as a document and extract local segments from the time series as words. We extend a topic model, i.e., the Hierarchical probabilistic Latent Semantic Analysis (H-pLSA), which was originally developed for visual motion analysis to cluster a set of unlabelled multichannel time series. The H-pLSA models each channel of the multichannel time series using a local pLSA in the first layer. The topics learned in the local pLSA are then fed to a global pLSA in the second layer to discover the categories of multichannel time series. Experiments on a dataset extracted from multichannel Electrocardiography (ECG) signals demonstrate that the proposed method performs better than previous state-of-the-art approaches and is relatively robust to the variations of parameters including length of local segments and dictionary size. Although the experimental evaluation used the multichannel ECG signals in a biometric scenario, the proposed algorithm is a universal framework for multichannel biomedical time series clustering according to their structural similarity, which has many applications in biomedical time series management. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. The extension of the range of application of the CTC-800 climate chamber

    OpenAIRE

    DOLGIKH ARTEM; ALEXANDROVA NATALIA; POPOVA IRINA

    2017-01-01

    The article presents a research work aimed at potential improvement of the climate chamber CTC-800 to simplify the proof test of it and automate the processes it performs. To this end, the authors justify the need to apply the meter and controller of temperature and humidity of the MPR51 type as well as consider the functional MPR51-SHCH 4, its link with computer, and the compatibility of its operation with the climate chamber.

  13. Multichannel micromanipulator and chamber system for recording multineuronal activity in alert, non-human primates.

    Science.gov (United States)

    Gray, Charles M; Goodell, Baldwin; Lear, Alex

    2007-07-01

    We describe the design and performance of an electromechanical system for conducting multineuron recording experiments in alert non-human primates. The system is based on a simple design, consisting of a microdrive, control electronics, software, and a unique type of recording chamber. The microdrive consists of an aluminum frame, a set of eight linear actuators driven by computer-controlled miniature stepping motors, and two printed circuit boards (PCBs) that provide connectivity to the electrodes and the control electronics. The control circuitry is structured around an Atmel RISC-based microcontroller, which sends commands to as many as eight motor control cards, each capable of controlling eight motors. The microcontroller is programmed in C and uses serial communication to interface with a host computer. The graphical user interface for sending commands is written in C and runs on a conventional personal computer. The recording chamber is low in profile, mounts within a circular craniotomy, and incorporates a removable internal sleeve. A replaceable Sylastic membrane can be stretched across the bottom opening of the sleeve to provide a watertight seal between the cranial cavity and the external environment. This greatly reduces the susceptibility to infection, nearly eliminates the need for routine cleaning, and permits repeated introduction of electrodes into the brain at the same sites while maintaining the watertight seal. The system is reliable, easy to use, and has several advantages over other commercially available systems with similar capabilities.

  14. Multi-channel phase-equivalent transformation and supersymmetry

    OpenAIRE

    Shirokov, A. M.; Sidorenko, V. N.

    2000-01-01

    Phase-equivalent transformation of local interaction is generalized to the multi-channel case. Generally, the transformation does not change the number of the bound states in the system and their energies. However, with a special choice of the parameters, the transformation removes one of the bound states and is equivalent to the multi-channel supersymmetry transformation recently suggested by Sparenberg and Baye. Using the transformation, it is also possible to add a bound state to the discr...

  15. Mapping customer journeys in multichannel decision-making

    OpenAIRE

    Wolny, Julia; Charoensuksai, Nipawan

    2014-01-01

    This study is focused on multi-channel shopping, which refers to the integration of various channels in the consumer decision-making process. The term was coined in the early 2000s to signify the integration of offline and online shopping channels. It has since evolved to encompass the proliferating number of channels and media used to formulate, evaluate and execute buying decisions. With the explosion of mobile technologies and social media, multi-channel shopping has indeed become a journe...

  16. Multi-channel Kondo necklace

    International Nuclear Information System (INIS)

    Fazekas, P.; Kee Haeyoung.

    1993-06-01

    A multi-channel generalization of Doniach's Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins τ J , j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig

  17. Automation of the helium jet transport system for nuclear recoil products

    International Nuclear Information System (INIS)

    Bellido, Luis F.; Pedrosa, Paulo S.

    1996-09-01

    A computer code and an interface hardware to automate the acquisition data and the sample changer in a helium jet transport system of recoil nucleus was developed for an IBM or compatible personal microcomputer. The software works with a Spectrum-ACE/ADCAM ORTEC's multichannel analysers and the interface card uses the 03EFh port to command the sample changer. This system allows to measure, by gamma spectrometry, radionuclides with half-lives of order of seconds produced from nuclear reactions. (author)

  18. Fast multichannel analyser

    Energy Technology Data Exchange (ETDEWEB)

    Berry, A; Przybylski, M M; Sumner, I [Science Research Council, Daresbury (UK). Daresbury Lab.

    1982-10-01

    A fast multichannel analyser (MCA) capable of sampling at a rate of 10/sup 7/ s/sup -1/ has been developed. The instrument is based on an 8 bit parallel encoding analogue to digital converter (ADC) reading into a fast histogramming random access memory (RAM) system, giving 256 channels of 64 k count capacity. The prototype unit is in CAMAC format.

  19. A multi-channel microcomputer data acquisition system

    International Nuclear Information System (INIS)

    Loureiro, J.S.

    1987-01-01

    A data acquisition system was developed in order to transfer automatically to a 64 kb microcomputer the data generated by a nuclear spectroscopy system in a multichannel analyser. The data in the memory are stored in a floppy disk and will be further used as data entry for any spectrum analysis program, eliminating the tedious work of manually digitizing the spectrum and the possible mistakes associated with it. The developed system connected a POLYMAX 201 DP microcomputer, under CP/M operational system, to a NUCLEAR DATA MODEL ND-65 multichannel analyser and was planned for either local spectrum analysis in the microcomputer using a simplified program, or remote analysis in a mainframe using the sophisticated analysis program SAMPO. With the present system, the time spent between printing out of the 4096 channels with the multichannel analyser printer and its corresponding introduction in the analysis program has been reduced from about 6 hours to less than 2 minutes. (author)

  20. Multi-channel Kondo necklace

    Energy Technology Data Exchange (ETDEWEB)

    Fazekas, P; Haeyoung, Kee

    1993-06-01

    A multi-channel generalization of Doniach`s Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins {tau}{sub J}, j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig.

  1. How to Succeed with Multichannel Management

    DEFF Research Database (Denmark)

    Madsen, Christian; Kræmmergaard, Pernille

    2016-01-01

    . This interplay between traditional and e-government channels remains to be explained. There is also a lack of empirical knowledge of how government organizations can apply findings from user studies and migrate citizens online while simultaneously reducing traffic through traditional channels. Therefore...... the authors present a detailed longitudinal case study of how public authorities collaborated to create a multichannel strategy for a mandatory online self-service application for single parents. After the strategy was carried out there was an increase in the use of the application and a substantial reduction...... in calls. The authors offer contributions to the channel choice literature and recommendations on multichannel management to practitioners....

  2. Determination of optimum "multi-channel surface wave method" field parameters.

    Science.gov (United States)

    2012-12-01

    Multi-channel surface wave methods (especially the multi-channel analyses of surface wave method; MASW) are routinely used to : determine the shear-wave velocity of the subsurface to depths of 100 feet for site classification purposes. Users are awar...

  3. Multichannel strategy - the dominant approach in modern retailing

    OpenAIRE

    Stojković Dragan; Lovreta Stipe; Bogetić Zoran

    2016-01-01

    The purpose of this paper is to thoroughly analyse the concept of multichannel strategy, focussing on retail, to enable the academic community and marketers to better understand its advantages and disadvantages. This paper presents a comprehensive literature review and financial data analysis. The authors have analysed the financial data of 88 retail companies in the 2007 to 2014 period, and have proven that the importance of multichannel strategy has grown...

  4. A multi-channel integrated circuit for the readout of a microstrip gas chamber

    Energy Technology Data Exchange (ETDEWEB)

    Krummenacher, F.; Enz, C. (Smart Silicon Systems S.A., Lausanne (Switzerland)); Bellazzini, R. (Dipt. di Fisica, Pisa (Italy) INFN, Pisa (Italy))

    1992-03-15

    The design and test of an 8 channel integrated circuit for the readout of the microstrip gas chamber and other multielectrode detectors are described. The circuit is composed of 8 identical channels, each providing the amplification and the shaping of the signal delivered by the detector. The peaking time of the shaper is 25 ns and the overall amplifier gain is 8 mV/1000 e{sup -}. In addition to the analog output, each channel provides a TTL compatible digital output. The equivalent input noise is less than 700 e{sup -} rms and the total dc power consumption is about 5 mW/channel. To avoid a baseline shift due to the tail of the current issued from the detector, an adjustable pole-zero cancellation circuit has been included. (orig.).

  5. Multichannel quantum defect and reduced R-matrix

    International Nuclear Information System (INIS)

    Hategan, C.; Ionescu, R.A.; Cutoiu, D.; Gugiu, M.

    2002-01-01

    The collision of an electron with the atomic electronic core or the scattering of a nucleon on the atomic nucleus, usually, result into multiparticle excitations producing a resonance of a compound system, followed by its decay in reaction channels. Both in the electron-atom collisions and in nucleon-nucleus reactions, these multichannel resonances are described by poles of all R-Matrix elements. The resonances originating in single particle states, either in electron-atom collision or in nucleon-nucleus scattering, are approached in quite different descriptions. For example, the single-particle resonance in nuclear scattering is described, in R-Matrix Theory, by a perturbative method due to Bloch. The original single-nucleon state overlaps the actual states of the nucleus, resulting into a micro-giant description of the single particle resonance. The spectroscopic aspects of the single particle state, mixed with actual nuclear states, are subject of nucleon (or single particle) Strength Function. The electron, involving single particle Rydberg state in an atomic collision, 'avoids' its wave function mixing with that of inner multielectron core, because it is spatially far-away located from that core. This process is usually described by the Multichannel Quantum Defect Theory (MQDT). In the electron-atom scattering rather the effect of inner multielectron core on Rydberg electrons is studied by means of a global parameter, historically called 'Quantum Defect'. Both these types of resonances have in common the preserving of the single-particle wave function in a complex system with multiparticle excitations. In this work one approaches description of single-particle (electron or nucleon) resonance in a multichannel system. The single particle multichannel resonances are not longer described by a R-Matrix pole (specific for resonances originating in multiparticle excitations) but rather by a natural method for incorporating a single particle state in R-Matrix Theory

  6. Regimes of data output from an automated scanning system into a computer

    International Nuclear Information System (INIS)

    Ovsov, Yu.V.; Shaislamov, P.T.

    1984-01-01

    A method is described for accomplishment of rather a complex algorithm of various coordinate and service data transmission from different automated scanning system devices into a monitoring computer in the automated system for processing images from bubble chambers. The accepted data output algorithm and the developed appropriate equipment enable data transmission both in separate words and word arrays

  7. Automation of variable low-energy positron beam experiments

    CERN Document Server

    Jayapandian, J; Amarendra, G; Venugopal-Rao, G; Purniah, B; Viswanathan, B

    2000-01-01

    By exploiting the special BIOS interrupt (INT 1CH) of PC in conjunction with a compatible high-voltage controller card and menu-driven control program, we report here the automation of variable low-energy positron beam experiments. The beam experiment consists of monitoring the Doppler broadening lineshape parameters corresponding to the annihilation 511 keV gamma-ray at various positron beam implantation energies. The variation and monitoring of the sample high voltage, which determines positron beam energy, is carried out using a controller add-on card coupled to a 0-30 kV high-voltage unit. The design features of this controller card are discussed. This controller card is housed in a PC, which also houses a multichannel analyser (MCA) card. The MCA stores the Doppler energy spectrum of the annihilation gamma-ray. The interactive control program, written in Turbo C, carries out the assigned tasks. The design features of the automation and results are presented.

  8. A versatile interaction chamber for laser-based spectroscopic applications, with the emphasis on Laser-Induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Novotný, J.; Brada, M.; Petrilak, M.; Prochazka, D.; Novotný, K.; Hrdička, A.; Kaiser, J.

    2014-01-01

    The technical note describes the interaction chamber developed particularly for the laser spectroscopy technique applications, such as Laser-Induced Breakdown Spectroscopy (LIBS), Raman Spectroscopy and Laser-Induced Fluorescence. The chamber was designed in order to provide advanced possibilities for the research in mentioned fields and to facilitate routine research procedures. Parameters and the main benefits of the chamber are described, such as the built-in module for automatic 2D chemical mapping and the possibility to set different ambient gas conditions (pressure value and gas type). Together with the chamber description, selected LIBS application examples benefiting from chamber properties are described. - Highlights: • Development of the interaction chamber for LIBS applications • Example of automated chemical mapping of lead in a chalcopyrite sample • Example of LIBS measurement of fluorine in underpressure • Overview of chamber benefits

  9. Inhibition of light tunneling for multichannel excitations in longitudinally modulated waveguide arrays

    International Nuclear Information System (INIS)

    Lobanov, Valery E.; Vysloukh, Victor A.; Kartashov, Yaroslav V.

    2010-01-01

    We consider the evolution of multichannel excitations in longitudinally modulated waveguide arrays where the refractive index either oscillates out-of-phase in all neighboring waveguides or when it is modulated in phase in several central waveguides surrounded by out-of-phase oscillating neighbors. Both types of modulations allow resonant inhibition of light tunneling, but only the modulation of the latter type conserves the internal structure of multichannel excitations. We show that parameter regions where light tunneling inhibition is possible depend on the symmetry and structure of multichannel excitations. Antisymmetric multichannel excitations are more robust than their symmetric counterparts and experience nonlinearity-induced delocalization at higher amplitudes.

  10. Auralization of an orchestra using multichannel and multisource technique (A)

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2006-01-01

    Previous work has shown the importance of including source directivity in computer modeling for auralizations. A newer method to capture source directivity in auralizations is the multichannel technique, which uses multichannel anechoic recordings. In this study, five-channel anechoic recordings ...... made with a single channel orchestral anechoic recording using (ii) a surface source and (iii) a single omni-directional source. [Work supported by the National Science Foundation.]......Previous work has shown the importance of including source directivity in computer modeling for auralizations. A newer method to capture source directivity in auralizations is the multichannel technique, which uses multichannel anechoic recordings. In this study, five-channel anechoic recordings...... were obtained for every orchestral part of two symphonies at the Technical University of Denmark. Five-channel auralizations were then created for each instrument, located at its typical position on-stage in a concert hall, by convolving five impulse responses from sources that each represent...

  11. Multichannel detection of ionic currents through two nanopores fabricated on integrated Si3N4 membranes.

    Science.gov (United States)

    Yanagi, Itaru; Akahori, Rena; Aoki, Mayu; Harada, Kunio; Takeda, Ken-Ichi

    2016-08-16

    Integration of solid-state nanopores and multichannel detection of signals from each nanopore are effective measures for realizing high-throughput nanopore sensors. In the present study, we demonstrated fabrication of Si3N4 membrane arrays and the simultaneous measurement of ionic currents through two nanopores formed in two adjacent membranes. Membranes with thicknesses as low as 6.4 nm and small nanopores with diameters of less than 2 nm could be fabricated using the poly-Si sacrificial-layer process and multilevel pulse-voltage injection. Using the fabricated nanopore membranes, we successfully achieved simultaneous detection of clear ionic-current blockades when single-stranded short homopolymers (poly(dA)60) passed through two nanopores. In addition, we investigated the signal crosstalk and leakage current among separated chambers. When two nanopores were isolated on the front surface of the membrane, there was no signal crosstalk or leakage current between the chambers. However, when two nanopores were isolated on the backside of the Si substrate, signal crosstalk and leakage current were observed owing to high-capacitance coupling between the chambers and electrolysis of water on the surface of the Si substrate. The signal crosstalk and leakage current could be suppressed by oxidizing the exposed Si surface in the membrane chip. Finally, the observed ionic-current blockade when poly(dA)60 passed through the nanopore in the oxidized chip was approximately half of that observed in the non-oxidized chip.

  12. Value Creation Challenges in Multichannel Retail Business Models

    Directory of Open Access Journals (Sweden)

    Mika Yrjölä

    2014-08-01

    Full Text Available Purpose: The purpose of the paper is to identify and analyze the challenges of value creation in multichannel retail business models. Design/methodology/approach: With the help of semi-structured interviews with top executives from different retailing environments, this study introduces a model of value creation challenges in the context of multichannel retailing. The challenges are analyzed in terms of three retail business model elements, i.e., format, activities, and governance. Findings: Adopting a multichannel retail business model requires critical rethinking of the basic building blocks of value creation. First of all, as customers effortlessly move between multiple channels, multichannel formats can lead to a mismatch between customer and firm value. Secondly, retailers face pressures to use their activities to form integrated total offerings to customers. Thirdly, multiple channels might lead to organizational silos with conflicting goals. A careful orchestration of value creation is needed to determine the roles and incentives of the channel parties involved. Research limitations/implications: In contrast to previous business model literature, this study did not adopt a network-centric view. By embracing the boundary-spanning nature of the business model, other challenges and elements might have been discovered (e.g., challenges in managing relationships with suppliers. Practical implications: As a practical contribution, this paper has analyzed the challenges retailers face in adopting multichannel business models. Customer tendencies for showrooming behavior highlight the need for generating efficient lock-in strategies. Customized, personal offers and information are ways to increase customer value, differentiate from competition, and achieve lock-in. Originality/value: As a theoretical contribution, this paper empirically investigates value creation challenges in a specific context, lowering the level of abstraction in the mostly

  13. Gas chromatography vs. quantum cascade laser-based N2O flux measurements using a novel chamber design

    DEFF Research Database (Denmark)

    Bruemmer, Christian; Lyshede, Bjarne; Lempio, Dirk

    2017-01-01

    automated chamber system against a conventional gas chromatography (GC) approach using the same chambers plus an automated gas sampling unit with septum capped vials and subsequent laboratory GC analysis. Through its high precision and time resolution, data of the QCL system were used for quantifying...... as natural as possible. Further, applying linear regression to a 3 min data window with rejecting the first 2 min after closure and a sampling time of every 5 s proved to be sufficient for robust flux determination while ensuring that standard errors of N2O fluxes were still on a relatively low level...... spot from unintended shading and minimizes disturbance of throughfall, thereby complying with high quality requirements of long-term observation studies and research infrastructures....

  14. Use of trapezoidal shaping algorithm in the digital multi-channel system

    International Nuclear Information System (INIS)

    Wang Jihong; Wang Lianghou; Fang Zongliang

    2011-01-01

    It discusses one kind of digital filter technology-trapezoidal algorithm based on actual need of studying the digital multi-channel. Firstly, demonstrating the feasibility of the arithmetic with theoretical analysis; secondly, predigesting the process of the arithmetic; thirdly, simulating with MATLAB; lastly, using the arithmetic to measure data. The result of testing indicates trapezoidal shaping algorithm accords with the need of digital multi-channel shaping extraordinary. The best filter can be obtained by means of setting parameter due to superiority of digital multi-channel. (authors)

  15. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  16. Microfluidic Multichannel Flow Cytometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is a "Microfluidic Multichannel Flow Cytometer." Several novel concepts are integrated to produce the final design, which is compatible with...

  17. Selling to the multi-channel consumer : strategic and operational challenges for multi-channel retailers

    NARCIS (Netherlands)

    van Ameijden, D.; van Vulpen, J.; Huismans, J.; Wenting, R.; Krawczyk, A.; Weltevreden, J.W.J.; Krawczyk, A.C.

    2012-01-01

    Het ontwikkelen van een goede multichannel strategie is één van de belangrijkste uitdagingen waar retailers vandaag de dag voor staan. Een toenemend aantal ‘traditionele’ retailers ziet het opzetten van een webshop als een belangrijke aanvulling op hun fysieke winkels en probeert te profiteren van

  18. Interpreting complex data by methods of recognition and classification in an automated system of aerogeophysical material processing

    Energy Technology Data Exchange (ETDEWEB)

    Koval' , L.A.; Dolgov, S.V.; Liokumovich, G.B.; Ovcharenko, A.V.; Priyezzhev, I.I.

    1984-01-01

    The system of automated processing of aerogeophysical data, ASOM-AGS/YeS, is equipped with complex interpretation of multichannel measurements. Algorithms of factor analysis, automatic classification and apparatus of a priori specified (selected) decisive rules are used. The areas of effect of these procedures can be initially limited to the specified geological information. The possibilities of the method are demonstrated by the results of automated processing of the aerogram-spectrometric measurements in the region of the known copper-porphyr manifestation in Kazakhstan. This ore deposit was clearly noted after processing by the method of main components by complex aureole of independent factors U (severe increase), Th (noticeable increase), K (decrease).

  19. Automated electronic intruder simulator for evaluation of ultrasonic intrusion detectors

    International Nuclear Information System (INIS)

    1979-01-01

    An automated electronic intruder simulator for testing ultrasonic intrusion detectors is described. This simulator is primarily intended for use in environmental chambers to determine the effects of temperature and humidity on the operation of ultrasonic intrusion detectors

  20. Development of special automation devices and systems for the Zhezkazgan Copper Smeltery Melting Work

    International Nuclear Information System (INIS)

    Namazbaev, T.S.

    2005-01-01

    In the article the description of the automated systems of flux materials batching and the multichannel control of temperature over caisson of ore-thermal furnace and horizontal convectors of melting shop is resulted. Due to an original design of primary gauges and application of powerful controller of industrial purpose the developed systems meet the requirements of high reliability of the technological processes control and management in a combination to sufficient productivity on processing the measuring information. (author)

  1. A TDC integrated circuit for drift chamber readout

    International Nuclear Information System (INIS)

    Passaseo, M.; Petrolo, E.; Veneziano, S.

    1995-01-01

    A custom integrated circuit for the measurement of the signal drift-time coming from the KLOE chamber developed by INFN Sezione di Roma is presented. The circuit is a multichannel common start/stop TDC, with 32 channels per chip. The TDC integrated circuit will be developed as a full-custom device in 0.5 μm CMOS technology, with 1 ns LSB realized using a Gray counter working at the frequency of 1 GHz. The circuit is capable of detecting rising/falling edges, with a double edge resolution of 8 ns; the hits are recorded as 16 bit words, hits older than a programmable time window are discarded, if not confirmed by a stop signal. The chip has four event-buffers, which are used only if at least one hit is present in one of the 32 channels. The readout of the data passes through the I/O port at a speed of 33 MHz; empty channels are automatically skipped during the readout phase. (orig.)

  2. A TDC integrated circuit for drift chamber readout

    Energy Technology Data Exchange (ETDEWEB)

    Passaseo, M. [Istituto Nazionale di Fisica Nucleare, Rome (Italy); Petrolo, E. [Istituto Nazionale di Fisica Nucleare, Rome (Italy); Veneziano, S. [Istituto Nazionale di Fisica Nucleare, Rome (Italy)

    1995-12-11

    A custom integrated circuit for the measurement of the signal drift-time coming from the KLOE chamber developed by INFN Sezione di Roma is presented. The circuit is a multichannel common start/stop TDC, with 32 channels per chip. The TDC integrated circuit will be developed as a full-custom device in 0.5 {mu}m CMOS technology, with 1 ns LSB realized using a Gray counter working at the frequency of 1 GHz. The circuit is capable of detecting rising/falling edges, with a double edge resolution of 8 ns; the hits are recorded as 16 bit words, hits older than a programmable time window are discarded, if not confirmed by a stop signal. The chip has four event-buffers, which are used only if at least one hit is present in one of the 32 channels. The readout of the data passes through the I/O port at a speed of 33 MHz; empty channels are automatically skipped during the readout phase. (orig.).

  3. Multiplicity counting from fission chamber signals in the current mode

    Energy Technology Data Exchange (ETDEWEB)

    Pázsit, I. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); Pál, L. [Centre for Energy Research, Hungarian Academy of Sciences, 114, POB 49, H-1525 Budapest (Hungary); Nagy, L. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); Budapest University of Technology and Economics, Institute of Nuclear Techniques, H-1111 Budapest (Hungary)

    2016-12-11

    In nuclear safeguards, estimation of sample parameters using neutron-based non-destructive assay methods is traditionally based on multiplicity counting with thermal neutron detectors in the pulse mode. These methods in general require multi-channel analysers and various dead time correction methods. This paper proposes and elaborates on an alternative method, which is based on fast neutron measurements with fission chambers in the current mode. A theory of “multiplicity counting” with fission chambers is developed by incorporating Böhnel's concept of superfission [1] into a master equation formalism, developed recently by the present authors for the statistical theory of fission chamber signals [2,3]. Explicit expressions are derived for the first three central auto- and cross moments (cumulants) of the signals of up to three detectors. These constitute the generalisation of the traditional Campbell relationships for the case when the incoming events represent a compound Poisson distribution. Because now the expressions contain the factorial moments of the compound source, they contain the same information as the singles, doubles and triples rates of traditional multiplicity counting. The results show that in addition to the detector efficiency, the detector pulse shape also enters the formulas; hence, the method requires a more involved calibration than the traditional method of multiplicity counting. However, the method has some advantages by not needing dead time corrections, as well as having a simpler and more efficient data processing procedure, in particular for cross-correlations between different detectors, than the traditional multiplicity counting methods.

  4. Multichannel readout ASIC design flow for high energy physics and cosmic rays experiments

    International Nuclear Information System (INIS)

    Voronin, A; Malankin, E

    2016-01-01

    In the large-scale high energy physics and astrophysics experiments multi-channel readout application specific integrated circuits (ASICs) are widely used. The ASICs for such experiments are complicated systems, which usually include both analog and digital building blocks. The complexity and large number of channels in such ASICs require the proper methodological approach to their design. The paper represents the mixed-signal design flow of the ASICs for high energy physics and cosmic rays experiments. This flow was successfully embedded to the development of the read-out ASIC prototype for the muon chambers of the CBM experiment. The approach was approved in UMC CMOS MMRF 180 nm process. The design flow enable to analyse the mixed-signal system operation on the different levels: functional, behavioural, schematic and post layout including parasitic elements. The proposed design flow allows reducing the simulation period and eliminating the functionality mismatches on the very early stage of the design. (paper)

  5. Multichannel analyzer embedded in FPGA; Analizador multicanal embebido en FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Garcia D, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico); Ordaz G, O. O. [Universidad de Cordoba, Departamento de Arquitectura de Computadores, Electronica y Tecnologia Electronica, Campus de Rabanales, Ctra. N-IVa Km 396, 14071 Cordoba (Spain); Bravo M, I., E-mail: angelogarciad@hotmail.com [Universidad de Alcala de Henares, Departamento de Electronica, Campus Universitario, Carretera Madrid-Barcelona Km 33.600, 28801 Alcala de Henares, Madrid (Spain)

    2017-10-15

    Ionizing radiation has different applications, so it is a very significant and useful tool, which in turn can be dangerous for living beings if they are exposed to uncontrolled doses. However, due to its characteristics, it cannot be perceived by any of the senses of the human being, so that in order to know the presence of it, radiation detectors and additional devices are required to quantify and classify it. A multichannel analyzer is responsible for separating the different pulse heights that are generated in the detectors, in a certain number of channels; according to the number of bits of the analog to digital converter. The objective of the work was to design and implement a multichannel analyzer and its associated virtual instrument, for nuclear spectrometry. The components of the multichannel analyzer were created in VHDL hardware description language and packaged in the Xilinx Vivado design suite, making use of resources such as the ARM processing core that the System on Chip Zynq contains and the virtual instrument was developed on the LabView programming graphics platform. The first phase was to design the hardware architecture to be embedded in the FPGA and for the internal control of the multichannel analyzer the application was generated for the ARM processor in C language. For the second phase, the virtual instrument was developed for the management, control and visualization of the results. The data obtained as a result of the development of the system were observed graphically in a histogram showing the spectrum measured. The design of the multichannel analyzer embedded in FPGA was tested with two different radiation detection systems (hyper-pure germanium and scintillation) which allowed determining that the spectra obtained are similar in comparison with the commercial multichannel analyzers. (Author)

  6. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  7. Magma chamber interaction giving rise to asymmetric oscillations

    Science.gov (United States)

    Walwer, D.; Ghil, M.; Calais, E.

    2017-12-01

    Geodetic time series at four volcanoes (Okmok, Akutan, Shishaldin, and Réunion) are processed using Multi-channel Singular Spectrum Analysis (M-SSA) and reveal sawtooth-shaped oscillations ; the latter are characterized by short intervals of fast inflations followed by longer intervals of slower deflations. At Okmok and Akutan, the oscillations are first damped and then accentuated. At Okmok, the increase in amplitude of the oscillations is followed by an eruption. We first show that the dynamics of these four volcanoes bears similarities with that of a simple nonlinear, dissipative oscillator, indicating that the inflation-deflation episodes are relaxation oscillations. These observations imply that ab initio dynamical models of magma chambers should possess an asymmetric oscillatory regime. Next, based on the work of Whitehead and Helfrich [1991], we show that a model of two magma chambers — connected by a cylindrical conduit in which the magma viscosity depends on temperature — gives rise to asymmetric overpressure oscillations in the magma reservoirs. These oscillations lead to surface deformations that are consistent with those observed at the four volcanoes in this study. This relaxation oscillation regime occurs only when the vertical temperature gradient in the host rock between the two magma chambers is large enough and when the magma flux entering the volcanic system is sufficiently high. The magma being supplied by a deeper source region, the input flux depends on the pressure difference between the source and the deepest reservoir. When this difference is not sufficiently high, the magma flux exponentially decreases, leading to damped oscillations as observed at Akutan and Okmok. The combination of observational and modeling results clearly supports the role of relaxation oscillations in the dynamics of volcanic systems.

  8. Empirical Study on Multi-Channel Service Quality and Customer Loyalty of Retailers

    OpenAIRE

    Qi Yong-zhi

    2014-01-01

    This paper studies the influence of offline RSSQ (retailing store service quality), online store ESQ (E-service quality) and O2O MCISQ (multi-channel integration service quality) on traditional retailers' customer loyalty as well as the relation of them three in multi-channel retailing. 380 customers with both offline and online shopping experience at the same retailer's store are investigated. Through the structural equation model, we find out that in multi-channel retailing, RSSQ and MCISQ ...

  9. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  10. Numerical solution of the multichannel scattering problem

    International Nuclear Information System (INIS)

    Korobov, V.I.

    1992-01-01

    A numerical algorithm for solving the multichannel elastic and inelastic scattering problem is proposed. The starting point is the system of radial Schroedinger equations with linear boundary conditions imposed at some point R=R m placed somewhere in asymptotic region. It is discussed how the obtained linear equation can be splitted into a zero-order operator and its pertturbative part. It is shown that Lentini - Pereyra variable order finite-difference method appears to be very suitable for solving that kind of problems. The derived procedure is applied to dμ+t→tμ+d inelastic scattering in the framework of the adiabatic multichannel approach. 19 refs.; 1 fig.; 1 tab

  11. A fast multichannel analyser

    International Nuclear Information System (INIS)

    Berry, A.; Przybylski, M.M.; Sumner, I.

    1982-01-01

    A fast multichannel analyser (MCA) capable of sampling at a rate of 10 7 s -1 has been developed. The instrument is based on an 8 bit parallel encoding analogue to digital converter (ADC) reading into a fast histogramming random access memory (RAM) system, giving 256 channels of 64 k count capacity. The prototype unit is in CAMAC format. (orig.)

  12. Multichannel spin polarimeter for energy- and angle-dispersive photoemission measurements

    International Nuclear Information System (INIS)

    Kolbe, Michaela

    2011-01-01

    Spin polarization measurements of free electrons remain challenging since their first realization by Mott. The relevant quantity of a spin polarimeter is its figure of merit, FoM=S 2 I/I 0 , with the asymmetry function S and the ratio between scattered and primary intensity I/I 0 . State-of-the-art devices are based on single-channel scattering (spin-orbit or exchange interaction) which is characterized by FoM ≅10 -4 . On the other hand, modern hemispherical analyzers feature an efficient multichannel detection of spin-integral intensity with more than 10 4 data points simultaneously. In comparison between spin-resolved and spin-integral electron spectroscopy we are thus faced with a difference in counting efficiency by 8 orders of magnitude. The present work concentrates on the development and investigation of a novel technique for increasing the efficiency in spin-resolved electron spectroscopy by multichannel detection. The spin detector was integrated in a μ-metal shielded UHV-chamber and mounted behind a conventional hemispherical analyzer. The electrostatic lens system's geometry was determined by electron-optical simulations. The basic concept is the k parallel -conserving elastic scattering of the (0,0)-beam on a W(100) scattering crystal under 45 impact angle. It could be demonstrated that app. 960 data points (15 energy and 64 angular points) could be displayed simultaneously on a delayline detector in an energy interval of ≅3 eV. This leads to a two-dimensional figure of merit of FoM 2D =1.7. Compared to conventional spin detectors, the new type is thus characterized by a gain in efficiency of 4 orders of magnitude. The operational reliability of the new spin polarimeter could be proven by measurements with a Fe/MgO(100) and O p(1 x 1)/Fe(100)-sample, where results from the literature were reproduced with strongly decreased measuring time. Due to the high intensity it becomes possible, to investigate strongly reactive samples in a short time. This

  13. α spectrometer of parallel plate grid ionization chamber of high energy resolution

    International Nuclear Information System (INIS)

    Tong Boting; Wang Jianqing; Dong Mingli; Tang Peijia; Wang Xiaorong; Lin Cansheng

    2000-01-01

    Parallel plate grid ionization chamber with cathode area of 300 cm 2 was developed and applied to detect minimum α-emitters. It consist of a vacuum system, a gas cycle system of the parallel plate grid ionization chamber, electronics (a high voltage supply, a pre-amplifier and a main amplifier) and a computer-multichannel analyzer. The energy resolution is 23 keV FWHM for the 244 Cm electrostatic precipitated source. The integral background is typically 10 counts/h between 4 and 6 MeV. The detector efficiency is 50%. The minimum detecting activity is 3 x 10 -4 Bq (3σ, 30 hours). This spectrometer is suitable for detecting various samples, such as samples of the soil, water, air, bion, food, structural material, geology, archaeology, α-emitters of after processing and measuring α activity of accounting for and control of nuclear material and monitoring the artificial radioactivity nuclides of environment samples around nuclear facilities. The spectrometer is equipped with apparatus for preparing large area α source by using vacuum deposition or ultrasonic pulverization. The operating program of preparing source is simple. The source thickness can be kept in 40-60 μm/cm 2

  14. Acousto-Optic Applications for Multichannel Adaptive Optical Processor

    Science.gov (United States)

    1992-06-01

    AO cell and the two- channel line-scan camera system described in Subsection 4.1. The AO material for this IntraAction AOD-70 device was flint glass (n...Single-Channel 1.68 (flint glass ) 60,.0 AO Cell Multichannel 2.26 (TeO 2) 20.0 AO Cell Beam splitter 1.515 ( glass ) 50.8 Multichannel correlation was...Tone Intermodulation Dynamic Ranges of Longitudinal TeO2 Bragg Cells for Several Acoustic Power Densities 4-92 f f2 f 3 1 t SOURCE: Reference 21 TR-92

  15. Multichannel MAC Layer In Mobile Ad—Hoc Network

    Science.gov (United States)

    Logesh, K.; Rao, Samba Siva

    2010-11-01

    This paper we presented the design objectives and technical challenges in Multichannel MAC protocols in Mobile Ad-hoc Network. In IEEE 802.11 a/b/g standards allow use of multiple channels, only a single channel is popularly used, due to the lack of efficient protocols that enable use of Multiple Channels. Even though complex environments in ad hoc networks require a combined control of physical (PHY) and medium access control (MAC) layers resources in order to optimize performance. And also we discuss the characteristics of cross-layer frame and give a multichannel MAC approach.

  16. The Time Division Multi-Channel Communication Model and the Correlative Protocol Based on Quantum Time Division Multi-Channel Communication

    International Nuclear Information System (INIS)

    Liu Xiao-Hui; Pei Chang-Xing; Nie Min

    2010-01-01

    Based on the classical time division multi-channel communication theory, we present a scheme of quantum time-division multi-channel communication (QTDMC). Moreover, the model of quantum time division switch (QTDS) and correlative protocol of QTDMC are proposed. The quantum bit error rate (QBER) is analyzed and the QBER simulation test is performed. The scheme shows that the QTDS can carry out multi-user communication through quantum channel, the QBER can also reach the reliability requirement of communication, and the protocol of QTDMC has high practicability and transplantable. The scheme of QTDS may play an important role in the establishment of quantum communication in a large scale in the future. (general)

  17. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

    Directory of Open Access Journals (Sweden)

    Kristen M. Warren

    2016-03-01

    Full Text Available Photoplethysmographic (PPG waveforms are used to acquire pulse rate (PR measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA, limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.

  18. A multichannel analyzer computer system for simultaneously measuring 64 spectra

    International Nuclear Information System (INIS)

    Jin Yuheng; Wan Yuqing; Zhang Jiahong; Li Li; Chen Guozhu

    2000-01-01

    The author introduces a multichannel analyzer computer system for simultaneously measuring 64 spectra with 64 coded independent inputs. The system is developed for a double chopper neutron scattering time-of-flight spectrometer. The system structure, coding method, operating principle and performances are presented. The system can also be used for other nuclear physics experiments which need multichannel analyzer with independent coded inputs

  19. Robust adaptive multichannel SAR processing based on covariance matrix reconstruction

    Science.gov (United States)

    Tan, Zhen-ya; He, Feng

    2018-04-01

    With the combination of digital beamforming (DBF) processing, multichannel synthetic aperture radar(SAR) systems in azimuth promise well in high-resolution and wide-swath imaging, whereas conventional processing methods don't take the nonuniformity of scattering coefficient into consideration. This paper brings up a robust adaptive Multichannel SAR processing method which utilizes the Capon spatial spectrum estimator to obtain the spatial spectrum distribution over all ambiguous directions first, and then the interference-plus-noise covariance Matrix is reconstructed based on definition to acquire the Multichannel SAR processing filter. The performance of processing under nonuniform scattering coefficient is promoted by this novel method and it is robust again array errors. The experiments with real measured data demonstrate the effectiveness and robustness of the proposed method.

  20. Automation of the ANSTO working standard of measurement for the activity of radionuclides

    International Nuclear Information System (INIS)

    Buckman, S.M.

    1990-08-01

    The ANSTO working standard ion chamber is used routinely for the standardisation of a range of gamma emitting radio-isotopes. The ion chamber has recently been automated by replacing the AAEC type 292 Recycling Discriminator, timer module and model 43 teletype printer with the HP86B computer, HP-59501B voltage programmer and HP-6181C current source. The program 'MEASION', running on the Deltacom IBM AT clone, calculates the radioactivity, with full error statements, from the ion chamber measurements. Each of these programs is listed and discussed. 13 refs., 5 figs., tabs

  1. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  2. Separable expansion for realistic multichannel scattering problems

    International Nuclear Information System (INIS)

    Canton, L.; Cattapan, G.; Pisent, G.

    1987-01-01

    A new approach to the multichannel scattering problem with realistic local or nonlocal interactions is developed. By employing the negative-energy solutions of uncoupled Sturmian eigenvalue problems referring to simple auxiliary potentials, the coupling interactions appearing to the original multichannel problem are approximated by finite-rank potentials. By resorting to integral-equation tecniques the coupled-channel equations are then reduced to linear algebraic equations which can be straightforwardly solved. Compact algebraic expressions for the relevant scattering matrix elements are thus obtained. The convergence of the method is tasted in the single-channel case with realistic optical potentials. Excellent agreement is obtained with a few terms in the separable expansion for both real and absorptive interactions

  3. Development of a multichannel dosimeter for radiotherapy

    International Nuclear Information System (INIS)

    Menezes, Claudio Jose Mesquita

    2000-06-01

    In radiotherapy, verification of the patient dose is of great important for the success of the treatment. Uncertainties in the evaluation of this dose can produce serious complications such as the loss of the control of the disease and damage to normal tissue. Semiconductor detectors present advantages over other types of radiation detectors such as ionization chambers and thermoluminescent dosimeters including small dimensions, high sensitivity and fast response. In this work, a multichannel dosimetric system is linear with dose, for a 6 MV x-ray beam and also with a beam of cobalt-60 gamma rays. The coefficients of determination of the calibration curves were better then 0,9998 in all cases. The four sensors presented similar response with the dose for different field sizes. The variation of the response was smaller than 1%. In a related study, depth dose was measured, and the results showed a good agreement compared to theoretical values. The angular response of the detectors showed a variation of 7% for angles of 45 deg C. Using the Anderson Random phantom, dose at the isocenter was determined from measurements of the surface dose. From the results obtained it can be concluded that the dosimetric system developed is adequate for the evaluation of many parameters in radiation fields used in radiotherapy. This system can be used to measure the patient entrance dose under treatment conditions, and the equipment can be used in the radiotherapy quality assurance program. (author)

  4. Multichannel photonic Hilbert transformers based on complex modulated integrated Bragg gratings.

    Science.gov (United States)

    Cheng, Rui; Chrostowski, Lukas

    2018-03-01

    Multichannel photonic Hilbert transformers (MPHTs) are reported. The devices are based on single compact spiral integrated Bragg gratings on silicon with coupling coefficients precisely modulated by the phase of each grating period. MPHTs with up to nine wavelength channels and a single-channel bandwidth of up to ∼625  GHz are achieved. The potential of the devices for multichannel single-sideband signal generation is suggested. The work offers a new possibility of utilizing wavelength as an extra degree of freedom in designing radio-frequency photonic signal processors. Such multichannel processors are expected to possess improved capacities and a potential to greatly benefit current widespread wavelength division multiplexed systems.

  5. Fast multichannel scaler

    International Nuclear Information System (INIS)

    Okayasu, T.; Takeuchi, S.; Nagai, S.

    1987-01-01

    A fast multichannel scaler achieving the minimum dwell time of 50 ns is described. The dead time due to memory cycle is eliminated by 4-phase operation of parallel-4 groups of counter RAMs. The MCS has 4 k channels in total. Differential nonlinearity is less than 0.4%. If an input pulse arrives near the channel boundary, it is caught temporarily for both channels and then sorted to go into a proper channel. Thus, the dead time near the channel boundary is also eliminated

  6. Modeling high dimensional multichannel brain signals

    KAUST Repository

    Hu, Lechuan

    2017-03-27

    In this paper, our goal is to model functional and effective (directional) connectivity in network of multichannel brain physiological signals (e.g., electroencephalograms, local field potentials). The primary challenges here are twofold: first, there are major statistical and computational difficulties for modeling and analyzing high dimensional multichannel brain signals; second, there is no set of universally-agreed measures for characterizing connectivity. To model multichannel brain signals, our approach is to fit a vector autoregressive (VAR) model with sufficiently high order so that complex lead-lag temporal dynamics between the channels can be accurately characterized. However, such a model contains a large number of parameters. Thus, we will estimate the high dimensional VAR parameter space by our proposed hybrid LASSLE method (LASSO+LSE) which is imposes regularization on the first step (to control for sparsity) and constrained least squares estimation on the second step (to improve bias and mean-squared error of the estimator). Then to characterize connectivity between channels in a brain network, we will use various measures but put an emphasis on partial directed coherence (PDC) in order to capture directional connectivity between channels. PDC is a directed frequency-specific measure that explains the extent to which the present oscillatory activity in a sender channel influences the future oscillatory activity in a specific receiver channel relative all possible receivers in the network. Using the proposed modeling approach, we have achieved some insights on learning in a rat engaged in a non-spatial memory task.

  7. Modeling high dimensional multichannel brain signals

    KAUST Repository

    Hu, Lechuan; Fortin, Norbert; Ombao, Hernando

    2017-01-01

    In this paper, our goal is to model functional and effective (directional) connectivity in network of multichannel brain physiological signals (e.g., electroencephalograms, local field potentials). The primary challenges here are twofold: first, there are major statistical and computational difficulties for modeling and analyzing high dimensional multichannel brain signals; second, there is no set of universally-agreed measures for characterizing connectivity. To model multichannel brain signals, our approach is to fit a vector autoregressive (VAR) model with sufficiently high order so that complex lead-lag temporal dynamics between the channels can be accurately characterized. However, such a model contains a large number of parameters. Thus, we will estimate the high dimensional VAR parameter space by our proposed hybrid LASSLE method (LASSO+LSE) which is imposes regularization on the first step (to control for sparsity) and constrained least squares estimation on the second step (to improve bias and mean-squared error of the estimator). Then to characterize connectivity between channels in a brain network, we will use various measures but put an emphasis on partial directed coherence (PDC) in order to capture directional connectivity between channels. PDC is a directed frequency-specific measure that explains the extent to which the present oscillatory activity in a sender channel influences the future oscillatory activity in a specific receiver channel relative all possible receivers in the network. Using the proposed modeling approach, we have achieved some insights on learning in a rat engaged in a non-spatial memory task.

  8. Modeling High-Dimensional Multichannel Brain Signals

    KAUST Repository

    Hu, Lechuan

    2017-12-12

    Our goal is to model and measure functional and effective (directional) connectivity in multichannel brain physiological signals (e.g., electroencephalograms, local field potentials). The difficulties from analyzing these data mainly come from two aspects: first, there are major statistical and computational challenges for modeling and analyzing high-dimensional multichannel brain signals; second, there is no set of universally agreed measures for characterizing connectivity. To model multichannel brain signals, our approach is to fit a vector autoregressive (VAR) model with potentially high lag order so that complex lead-lag temporal dynamics between the channels can be captured. Estimates of the VAR model will be obtained by our proposed hybrid LASSLE (LASSO + LSE) method which combines regularization (to control for sparsity) and least squares estimation (to improve bias and mean-squared error). Then we employ some measures of connectivity but put an emphasis on partial directed coherence (PDC) which can capture the directional connectivity between channels. PDC is a frequency-specific measure that explains the extent to which the present oscillatory activity in a sender channel influences the future oscillatory activity in a specific receiver channel relative to all possible receivers in the network. The proposed modeling approach provided key insights into potential functional relationships among simultaneously recorded sites during performance of a complex memory task. Specifically, this novel method was successful in quantifying patterns of effective connectivity across electrode locations, and in capturing how these patterns varied across trial epochs and trial types.

  9. Multi-channel imaging cytometry with a single detector

    Science.gov (United States)

    Locknar, Sarah; Barton, John; Entwistle, Mark; Carver, Gary; Johnson, Robert

    2018-02-01

    Multi-channel microscopy and multi-channel flow cytometry generate high bit data streams. Multiple channels (both spectral and spatial) are important in diagnosing diseased tissue and identifying individual cells. Omega Optical has developed techniques for mapping multiple channels into the time domain for detection by a single high gain, high bandwidth detector. This approach is based on pulsed laser excitation and a serial array of optical fibers coated with spectral reflectors such that up to 15 wavelength bins are sequentially detected by a single-element detector within 2.5 μs. Our multichannel microscopy system uses firmware running on dedicated DSP and FPGA chips to synchronize the laser, scanning mirrors, and sampling clock. The signals are digitized by an NI board into 14 bits at 60MHz - allowing for 232 by 174 pixel fields in up to 15 channels with 10x over sampling. Our multi-channel imaging cytometry design adds channels for forward scattering and back scattering to the fluorescence spectral channels. All channels are detected within the 2.5 μs - which is compatible with fast cytometry. Going forward, we plan to digitize at 16 bits with an A-toD chip attached to a custom board. Processing these digital signals in custom firmware would allow an on-board graphics processing unit to display imaging flow cytometry data over configurable scanning line lengths. The scatter channels can be used to trigger data buffering when a cell is present in the beam. This approach enables a low cost mechanically robust imaging cytometer.

  10. Multichannel scaler with fast channel advance

    International Nuclear Information System (INIS)

    Murphy, D.M.

    1985-01-01

    A multichannel scaler has been constructed which is capable of running as fast as 250 ns per channel. It is compact, low power and requires no special construction techniques. Readout is into a memory accessible by a microprocessor. (orig.)

  11. Design and construction of an inexpensive homemade plant growth chamber.

    Science.gov (United States)

    Katagiri, Fumiaki; Canelon-Suarez, Dario; Griffin, Kelsey; Petersen, John; Meyer, Rachel K; Siegle, Megan; Mase, Keisuke

    2015-01-01

    Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W) x 1.8 m (D) x 2 m (H), providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant growth chamber

  12. Design and construction of an inexpensive homemade plant growth chamber.

    Directory of Open Access Journals (Sweden)

    Fumiaki Katagiri

    Full Text Available Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W x 1.8 m (D x 2 m (H, providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant

  13. Automated photosynthesis of 11C-glucose

    International Nuclear Information System (INIS)

    Ishiwata, K.; Monma, M.; Iwata, R.; Ido, T.

    1982-01-01

    Glucose and fructose, labelled with 11 C, were produced by passing 11 CO 2 into an evacuated chamber containing spinach leaves. Photosynthesis was carried out by day light lamp illumination. 75-95% of the 11 CO 2 was absorbed by the leaves and the radioactivity in the leaves was extracted in ethanol as sugars. Radiochemical purity was determined by HPLC. The automated system was controlled by timers. (U.K.)

  14. Multiwire proportional chambers in the devices for molecular biology constructed at JINR

    Energy Technology Data Exchange (ETDEWEB)

    Anisimov, Y S; Chernenko, S P; Ivanov, A B; Peshekhonov, V D; Skvaril, J; Zanevsky, Y V [Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of High Energy; Kheiker, D M [Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of High Energy; AN SSSR, Moscow. Inst. Kristallografii)

    1980-10-01

    The automation of measuring processes in molecular biology is a current problem. In order to solve this problem, conventionally used methods should be changed for an up-to-date technique which allows the processes of data measurement and analysis to be automated. Toward this end two-coordinate proportional chambers (MWPCs) are coming widely into use. The use of MWPCs in devices for radiochromatography and x-ray diffractrometry is discussed in this paper. A new device consisting of proportional chambers has been constructed for an automated analysis of thin layer radiochromatograms. The device enables one to localize radioactive zones (labelled with /sup 3/H, /sup 14/C, /sup 32/P), to identify radionuclides and to measure their activities. The device has a high sensitivity (5 pCi for tritium), a small dead time, good space resolution (in the case of /sup 3/H zones spaced 1-2 mm apart are separated) and high reproducibility. For x-ray diffractometry of single crystals, a high counting rate device has been constructed on the basis of a MWPC with a total number of channels amounting to 350 x 200 = 70,000. The dead time of the device is about 0.6 ..mu..s which allows to detect 3 x 10/sup 5/ events/s at counting losses of no more than 20%. The quantum efficiency (Cu K..cap alpha..) is about 73%. The X and Y space resolution (fwhm) is equal to 1 mm and 1.7 mm, respectively.

  15. Multichannel shopper segments and their covariates

    NARCIS (Netherlands)

    Konus, U.; Verhoef, P.C.; Neslin, S.A.

    2008-01-01

    The proliferation of channels has created new challenges for research, including understanding how consumers may be segmented with respect to their information search and purchase behavior in multichannel environment. This research considers shopping a dynamic process that consists of search and

  16. Multichannel Shopper Segments and Their Covariates

    NARCIS (Netherlands)

    Konus, Umut; Verhoef, Peter C.; Neslin, Scott A.

    2008-01-01

    The proliferation of channels has created new challenges for research, including understanding how consumers may be segmented with respect to their information search and purchase behavior in multichannel environment. This research considers shopping a dynamic process that consists of search and

  17. Thermal System Upgrade of the Space Environment Simulation Test Chamber

    Science.gov (United States)

    Desai, Ashok B.

    1997-01-01

    The paper deals with the refurbishing and upgrade of the thermal system for the existing thermal vacuum test facility, the Space Environment Simulator, at NASA's Goddard Space Flight Center. The chamber is the largest such facility at the center. This upgrade is the third phase of the long range upgrade of the chamber that has been underway for last few years. The first phase dealt with its vacuum system, the second phase involved the GHe subsystem. The paper describes the considerations of design philosophy options for the thermal system; approaches taken and methodology applied, in the evaluation of the remaining "life" in the chamber shrouds and related equipment by conducting special tests and studies; feasibility and extent of automation, using computer interfaces and Programmable Logic Controllers in the control system and finally, matching the old components to the new ones into an integrated, highly reliable and cost effective thermal system for the facility. This is a multi-year project just started and the paper deals mainly with the plans and approaches to implement the project successfully within schedule and costs.

  18. Multichannel blind iterative image restoration

    Czech Academy of Sciences Publication Activity Database

    Šroubek, Filip; Flusser, Jan

    2003-01-01

    Roč. 12, č. 9 (2003), s. 1094-1106 ISSN 1057-7149 R&D Projects: GA ČR GA102/00/1711 Institutional research plan: CEZ:AV0Z1075907 Keywords : conjugate gradient * half-quadratic regularization * multichannel blind deconvolution Subject RIV: BD - Theory of Information Impact factor: 2.642, year: 2003 http://library.utia.cas.cz/prace/20030104.pdf

  19. Quasibound states at thresholds in multichannel impurity scattering

    International Nuclear Information System (INIS)

    Kim, Sang Wook; Park, Hwa-Kyun; Sim, H-S; Schomerus, Henning

    2003-01-01

    We investigate the threshold behaviour of transmission resonances and quasibound states in the multichannel scattering problems of a one-dimensional (1D) time-dependent impurity potential, and the related problem of a single impurity in a quasi-1D wire. It was claimed before in the literature that a quasibound state disappears when a transmission zero collides with the subband boundary. However, the transmission line shape, the Friedel sum rule, and the delay time show that the quasibound states still survive and affect the physical quantities. We discuss the relation between threshold behaviour of transmission resonances, and quasibound states and their boundary conditions in the general context of multichannel scatterings

  20. Data Stream Processing Study in a Multichannel Telemetry Data Registering System

    Directory of Open Access Journals (Sweden)

    I. M. Sidyakin

    2015-01-01

    Full Text Available The paper presents the results of research that is aimed to improve the reliability of transmission of telemetry information (TMI through a communication channel with noise from the object of telemeasurements to the telemetry system for collecting and processing data. It considers the case where the quality of received information changes over time, due to movement of the object relative to the receiving station, or other factors that cause changes in the characteristics of noise in the channel, up to the total loss due to some temporary sites. To improve the reliability of transmission and ensure continuous communication with the object, it is proposed to use a multi-channel system to record the TMI. This system consists of several telemetry stations, which simultaneously register data stream transmitted from the telemetry object. The multichannel system generates a single stream of TMI for the user at the output. The stream comprises the most reliable pieces of information, being received at all inputs of the system.The paper investigates the task of constructing a multi-channel registration scheme for telemetry information (TMI to provide a simultaneous reception of the telemeasurement data by multiple telemetry stations and to form a single TMI stream containing the most reliable pieces of received data on the basis of quality analysis of information being received.In a multichannel registering system of TMI there are three main factors affecting the quality of the output of a single stream of information: 1 quality of the method used for protecting against errors during transmission over the communication channel with noise; 2 efficiency of the synchronization process of telemetry frames in the received flow of information; 3 efficiency of the applied criteria to form a single output stream from multiple input streams coming from different stations in the discussed multichannel registering system of TMI.In the paper, in practical

  1. Relativistic Multichannel Treatment of Krypton Spectra across the First Ionization Threshold

    Institute of Scientific and Technical Information of China (English)

    QU Yi-Zhi; PENG Yong-Lun

    2005-01-01

    @@ The relativistic multichannel theory has been extended to calculate both the eigen quantum defects μα, transformation matrix Uiα, and the eigen dipole matrix elements Dα of krypton. The Rydberg and autoionizationspectra of krypton across the first ionization threshold are calculated within the framework of multichannel quantum defect theory. Our calculated spectra are in agreement with the absolute measurement data.

  2. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  3. Multichannel imager for littoral zone characterization

    Science.gov (United States)

    Podobna, Yuliya; Schoonmaker, Jon; Dirbas, Joe; Sofianos, James; Boucher, Cynthia; Gilbert, Gary

    2010-04-01

    This paper describes an approach to utilize a multi-channel, multi-spectral electro-optic (EO) system for littoral zone characterization. Advanced Coherent Technologies, LLC (ACT) presents their EO sensor systems for the surf zone environmental assessment and potential surf zone target detection. Specifically, an approach is presented to determine a Surf Zone Index (SZI) from the multi-spectral EO sensor system. SZI provides a single quantitative value of the surf zone conditions delivering an immediate understanding of the area and an assessment as to how well an airborne optical system might perform in a mine countermeasures (MCM) operation. Utilizing consecutive frames of SZI images, ACT is able to measure variability over time. A surf zone nomograph, which incorporates targets, sensor, and environmental data, including the SZI to determine the environmental impact on system performance, is reviewed in this work. ACT's electro-optical multi-channel, multi-spectral imaging system and test results are presented and discussed.

  4. A multi-channel isolated power supply in non-equipotential circuit

    Science.gov (United States)

    Li, Xiang; Zhao, Bo-Wen; Zhang, Yan-Chi; Xie, Da

    2018-04-01

    A multi-channel isolation power supply is designed for the problems of different MOSFET or IGBT in the non-equipotential circuit in this paper. It mainly includes the square wave generation circuit, the high-frequency transformer and the three-terminal stabilized circuit. The first part is used to generate the 24V square wave, and as the input of the magnetic ring transformer. In the second part, the magnetic ring transformer consists of one input and three outputs to realize multi-channel isolation output. The third part can output different potential and realize non-equal potential function through the three-terminal stabilized chip. In addition, the multi-channel isolation power source proposed in this paper is Small size, high reliability and low price, and it is convenient for power electronic switches that operate on multiple different potentials. Therefore, the research on power supply of power electronic circuit has practical significance.

  5. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    Science.gov (United States)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  6. A multichannel pulse acquisition system for reactor dosimetry data

    International Nuclear Information System (INIS)

    Talpalariu, C.; Talpalariu, J.; Matei, C.

    1999-01-01

    Simultaneous measurements of many dosimetry parameters require a complex instrumentation equipment, computers and interfaces. For a very large frequency range (10 -3 to 10 6 Hz) scale and mode selection (period or frequency), a big problem in multichannel pulse measurement is that of dead time, precision and response time. The dead time for normal scale selection and for data reading or writing for every channel can be as long as the active measuring time and response time for very large frequency variation can be very long, too. To solve this problem we have designed for a simultaneous 40 channel measurement, a pulse counter sampling system and an expert operating system. Based on a 486 PC and a 10 channel Timer/Counter Card, the hardware performance of the system was improved by an expert program for early rate change detection and rate prediction. The rate value was determined from optimizing between current value, medium and long time values and shorter response time for transient signals. Significant features and advantages of the system are the following: a marked reduction in panel complexity, as many of the indicators and controls can be replaced by an interactive CRT keyboard, a reduction in the instrumentation complexity, failure detection and diagnosis, system performance monitoring, intelligent alarm handling. The system was designed from high accuracy measurements on 40 simultaneous channels fed from field radiation detectors like ionizing chambers, fission chambers and photomultipliers.. The operating system is using an auto-organizing data memory for both computing the current value and for long-term management of data, so that only the status and significant values of the input are recorded. Consequently, the algorithms of decision, search and data processing are simplified and limited to the necessary memory, although enough memory is preserved for accurate representation of the dosimetry curves. The utilization of an inferential algorithm for the

  7. A Facility for Long-Term Mars Simulation Experiments: The Mars Environmental Simulation Chamber (MESCH)

    Science.gov (United States)

    Jensen, Lars Liengaard; Merrison, Jonathan; Hansen, Aviaja Anna; Mikkelsen, Karina Aarup; Kristoffersen, Tommy; Nørnberg, Per; Lomstein, Bente Aagaard; Finster, Kai

    2008-06-01

    We describe the design, construction, and pilot operation of a Mars simulation facility comprised of a cryogenic environmental chamber, an atmospheric gas analyzer, and a xenon/mercury discharge source for UV generation. The Mars Environmental Simulation Chamber (MESCH) consists of a double-walled cylindrical chamber. The double wall provides a cooling mantle through which liquid N2 can be circulated. A load-lock system that consists of a small pressure-exchange chamber, which can be evacuated, allows for the exchange of samples without changing the chamber environment. Fitted within the MESCH is a carousel, which holds up to 10 steel sample tubes. Rotation of the carousel is controlled by an external motor. Each sample in the carousel can be placed at any desired position. Environmental data, such as temperature, pressure, and UV exposure time, are computer logged and used in automated feedback mechanisms, enabling a wide variety of experiments that include time series. Tests of the simulation facility have successfully demonstrated its ability to produce temperature cycles and maintain low temperature (down to -140°C), low atmospheric pressure (5 10 mbar), and a gas composition like that of Mars during long-term experiments.

  8. Automated DNA electrophoresis, hybridization and detection

    International Nuclear Information System (INIS)

    Zapolski, E.J.; Gersten, D.M.; Golab, T.J.; Ledley, R.S.

    1986-01-01

    A fully automated, computer controlled system for nucleic acid hybridization analysis has been devised and constructed. In practice, DNA is digested with restriction endonuclease enzyme(s) and loaded into the system by pipette; 32 P-labelled nucleic acid probe(s) is loaded into the nine hybridization chambers. Instructions for all the steps in the automated process are specified by answering questions that appear on the computer screen at the start of the experiment. Subsequent steps are performed automatically. The system performs horizontal electrophoresis in agarose gel, fixed the fragments to a solid phase matrix, denatures, neutralizes, prehybridizes, hybridizes, washes, dries and detects the radioactivity according to the specifications given by the operator. The results, printed out at the end, give the positions on the matrix to which radioactivity remains hybridized following stringent washing

  9. Design of multichannel counting system for IBM PC and compatibles

    International Nuclear Information System (INIS)

    Majeed, B.; Ahmad, Z.; Osman, A.; Ysain, M.M.

    1995-07-01

    A Multichannel Counting System (MCCS), based on IBM-PC and compatible computer systems have been designed. The MCCS consists of a Multichannel Counting System plug-in interface card (MCCS-PC) for IBM PC and compatibles and a NIM-BIN module (MCCS-NB). The MCCS-PC provides simultaneous monitoring of upto seven independent SCA type inputs. An on board programmable timer provides elapsed time measurement. A menu-driven program for data acquisition and timer control has also been developed. (author) 8 figs

  10. Artificial Walking Technologies to Improve Gait in Cerebral Palsy: Multichannel Neuromuscular Stimulation.

    Science.gov (United States)

    Rose, Jessica; Cahill-Rowley, Katelyn; Butler, Erin E

    2017-11-01

    Cerebral palsy (CP) is the most common childhood motor disability and often results in debilitating walking abnormalities, such as flexed-knee and stiff-knee gait. Current medical and surgical treatments are only partially effective in improving gait abnormalities and may cause significant muscle weakness. However, emerging artificial walking technologies, such as step-initiated, multichannel neuromuscular electrical stimulation (NMES), can substantially improve gait patterns and promote muscle strength in children with spastic CP. NMES may also be applied to specific lumbar-sacral sensory roots to reduce spasticity. Development of tablet computer-based multichannel NMES can leverage lightweight, wearable wireless stimulators, advanced control design, and surface electrodes to activate lower-limb muscles. Musculoskeletal models have been used to characterize muscle contributions to unimpaired gait and identify high muscle demands, which can help guide multichannel NMES-assisted gait protocols. In addition, patient-specific NMES-assisted gait protocols based on 3D gait analysis can facilitate the appropriate activation of lower-limb muscles to achieve a more functional gait: stance-phase hip and knee extension and swing-phase sequence of hip and knee flexion followed by rapid knee extension. NMES-assisted gait treatment can be conducted as either clinic-based or home-based programs. Rigorous testing of multichannel NMES-assisted gait training protocols will determine optimal treatment dosage for future clinical trials. Evidence-based outcome evaluation using 3D kinematics or temporal-spatial gait parameters will help determine immediate neuroprosthetic effects and longer term neurotherapeutic effects of step-initiated, multichannel NMES-assisted gait in children with spastic CP. Multichannel NMES is a promising assistive technology to help children with spastic CP achieve a more upright, functional gait. © 2017 International Center for Artificial Organs and

  11. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  12. Multichannel Human Body Communication

    International Nuclear Information System (INIS)

    Przystup, Piotr; Bujnowski, Adam; Wtorek, Jerzy

    2016-01-01

    Human Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog signal has been tested. Experiment results show that HBC is a feasible solution for transmitting data between BSN nodes

  13. Challenges and opportunities in multichannel customer management

    NARCIS (Netherlands)

    Neslin, Scott A.; Grewal, Dhruv; Leghorn, Robert; Shankar, Venkatesh; Teerling, Marije L.; Thomas, Jacquelyn S.; Verhoef, Peter C.

    Multichannel customer management is the design, deployment, coordination, and evaluation of channels through which firms and customers interact, with the goal of enhancing customer value through effective customer acquisition, retention, and development. The authors identify five major challenges

  14. Challenges and opportunities in multichannel customer management

    NARCIS (Netherlands)

    Neslin, Scott A.; Grewal, Dhruv; Leghorn, Robert; Shankar, Venkatesh; Teerling, Marije L.; Thomas, Jacquelyn S.; Verhoef, Peter C.

    2006-01-01

    Multichannel customer management is the design, deployment, coordination, and evaluation of channels through which firms and customers interact, with the goal of enhancing customer value through effective customer acquisition, retention, and development. The authors identify five major challenges

  15. Multichannel sound reinforcement systems at work in a learning environment

    Science.gov (United States)

    Malek, John; Campbell, Colin

    2003-04-01

    Many people have experienced the entertaining benefits of a surround sound system, either in their own home or in a movie theater, but another application exists for multichannel sound that has for the most part gone unused. This is the application of multichannel sound systems to the learning environment. By incorporating a 7.1 surround processor and a touch panel interface programmable control system, the main lecture hall at the University of Michigan Taubman College of Architecture and Urban Planning has been converted from an ordinary lecture hall to a working audiovisual laboratory. The multichannel sound system is used in a wide variety of experiments, including exposure to sounds to test listeners' aural perception of the tonal characteristics of varying pitch, reverberation, speech transmission index, and sound-pressure level. The touch panel's custom interface allows a variety of user groups to control different parts of the AV system and provides preset capability that allows for numerous system configurations.

  16. Direct and simultaneous estimation of cardiac four chamber volumes by multioutput sparse regression.

    Science.gov (United States)

    Zhen, Xiantong; Zhang, Heye; Islam, Ali; Bhaduri, Mousumi; Chan, Ian; Li, Shuo

    2017-02-01

    Cardiac four-chamber volume estimation serves as a fundamental and crucial role in clinical quantitative analysis of whole heart functions. It is a challenging task due to the huge complexity of the four chambers including great appearance variations, huge shape deformation and interference between chambers. Direct estimation has recently emerged as an effective and convenient tool for cardiac ventricular volume estimation. However, existing direct estimation methods were specifically developed for one single ventricle, i.e., left ventricle (LV), or bi-ventricles; they can not be directly used for four chamber volume estimation due to the great combinatorial variability and highly complex anatomical interdependency of the four chambers. In this paper, we propose a new, general framework for direct and simultaneous four chamber volume estimation. We have addressed two key issues, i.e., cardiac image representation and simultaneous four chamber volume estimation, which enables accurate and efficient four-chamber volume estimation. We generate compact and discriminative image representations by supervised descriptor learning (SDL) which can remove irrelevant information and extract discriminative features. We propose direct and simultaneous four-chamber volume estimation by the multioutput sparse latent regression (MSLR), which enables jointly modeling nonlinear input-output relationships and capturing four-chamber interdependence. The proposed method is highly generalized, independent of imaging modalities, which provides a general regression framework that can be extensively used for clinical data prediction to achieve automated diagnosis. Experiments on both MR and CT images show that our method achieves high performance with a correlation coefficient of up to 0.921 with ground truth obtained manually by human experts, which is clinically significant and enables more accurate, convenient and comprehensive assessment of cardiac functions. Copyright © 2016 Elsevier

  17. Automatic control system for measuring currents produced by ionization chambers; Automatizacao de um sistema de medidas de correntes produzidas por camaras de ionizacao e aplicacao na calibracao do {sup 18}F e {sup 153}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Brancaccio, Franco

    2002-07-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for {sup 18}F and {sup 153}Sm were obtained, making possible to determine activities of these radionuclides. (author)

  18. Multi-channel motor evoked potential monitoring during anterior cervical discectomy and fusion

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objectives: Anterior cervical discectomy and fusion (ACDF surgery is the most common surgical procedure for the cervical spine with low complication rate. Despite the potential prognostic benefit, intraoperative neurophysiological monitoring (IONM, a method for detecting impending neurological compromise, is not routinely used in ACDF surgery. The present study aimed to identify the potential benefits of monitoring multi-channel motor evoked potentials (MEPs during ACDF surgery. Methods: We retrospectively reviewed 200 consecutive patients who received IONM with multi-channel MEPs and somatosensory evoked potentials (SSEPs. On average, 9.2 muscles per patient were evaluated under MEP monitoring. Results: The rate of MEP change during surgery in the multi-level ACDF group was significantly higher than the single-level group. Two patients from the single-level ACDF group (1.7% and four patients from the multi-level ACDF group (4.9% experienced post-operative motor deficits. Multi-channel MEPs monitoring during single and multi-level ACDF surgery demonstrated higher sensitivity, specificity, positive predictive and negative predictive value than SSEP monitoring. Conclusions: Multi-channel MEP monitoring might be beneficial for the detection of segmental injury as well as long tract injury during single- and multi-level ACDF surgery. Significance: This is first large scale study to identify the usefulness of multi-channel MEPs in monitoring ACDF surgery. Keywords: Disc disease, Somatosensory evoked potentials, Intraoperative neurophysiological monitoring, Motor evoked potentials, Anterior cervical discectomy and fusion

  19. Herds of methane chambers grazing bubbles

    Science.gov (United States)

    Grinham, Alistair; Dunbabin, Matthew

    2014-05-01

    Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique

  20. A Large High Vacuum Reaction Chamber for Nuclear Physics Research at VECC, Kolkata

    International Nuclear Information System (INIS)

    Kundu, S; Bhattacharya, S; Meena, J K; Ghosh, T K; Bhattacharjee, T; Mukhopadhyay, P; Bhattacharya, C; Rana, T K; Banerjee, K; Mukherjee, G; Banerjee, S R; Bandyopadhyay, D L; Ahammed, M; Bhattacharya, P

    2012-01-01

    A large, segmented, horizontal axis, reaction chamber (SHARC) has recently been fabricated, installed and integrated with the beam line in the VECC superconducting cyclotron (SCC) experimental area. It is a cylindrical, three segment, stainless steel chamber of length 2.2 m, diameter 1 m. Two pairs of parallel rails have been provided internally for placement of the target assembly and detector systems within the chamber. The whole target assembly can be placed anywhere on the rail to facilitate optimum flight path. The nominal vacuum of ∼1×10 −7 mbar has been obtained in ∼8 hrs by means of two turbo molecular (1000 l/s) and two cryo pumps (2500 l/s) backed by mechanical pumps. The whole vacuum system as well as the target positioning (vertical and rotational movements) operations are fully automated with manual override option; both are monitored and controlled locally as well as remotely through the local and remote control units providing real time status display.

  1. AVME readout module for multichannel ASIC characterization

    International Nuclear Information System (INIS)

    Borkar, S.P.; Lalwani, S.K.; Ghodgaonkar, M.D.; Kataria, S.K.; Reynaud, Serge; )

    2004-01-01

    Electronics Division, BARC has been working on the development of multi-channel ASIC, called SPAIR (Silicon-strip Pulse Amplifier Integrated Readout). It contains 8 channels of preamplifier, shaper and track-and-hold circuitry. Electronics Division has also actively participated in development of test setup for the front-end ASIC, called PACE, for the preshower detector of the Compact Muon Solenoid (CMS) Experiment at CERN, Geneva. PACE is a 32 channel ASIC for silicon strip detector, containing preamplifier, shaper, calibration circuitry, switched capacitor array, readout amplifier per channel and an analog multiplexer. A VME Readout Module, (VRM) is developed which can be utilized in data acquisition from ASICs like PACE and SPAIR. The VRM can also be used as the Detector Dependent Unit for digitally processing the data received from the front-end electronics on the 16-bit LVDS port. The processed, data can be read by the VME system. Thus the VRM is very useful in building an ASIC characterization system and/or the automated ASIC production testing system. It can be used also to build the applications using such ASICs. To cater to various requirements arising in future, variety of VME modules are to be developed like ADCs, DACs and D 1/0. VME interface remains a common part to all these modules. The different functional blocks of these modules can be designed and fabricated on small piggyback boards (called Test Boards) and mounted on the VRM, which provides the common VME interface. The design details and uses of VRM are presented here. (author)

  2. Multichannel analyzer based on microprocessors

    International Nuclear Information System (INIS)

    Soares, M.

    1983-06-01

    A multichannel analyser for nuclear spectrometry, that would attend the needs of research laboratories and could be industrialized in Brazil, was developed. The design was based on INTEL 8080/85 microprocessors; other processors were also used to implement specific functions, such as shared busbar using direct memory access. A prototype was developed and tested through simulation, using a nuclear spectrometry chain. The results were fully satisfactory. (Author) [pt

  3. Automated microfluidic devices integrating solid-phase extraction, fluorescent labeling, and microchip electrophoresis for preterm birth biomarker analysis.

    Science.gov (United States)

    Sahore, Vishal; Sonker, Mukul; Nielsen, Anna V; Knob, Radim; Kumar, Suresh; Woolley, Adam T

    2018-01-01

    We have developed multichannel integrated microfluidic devices for automated preconcentration, labeling, purification, and separation of preterm birth (PTB) biomarkers. We fabricated multilayer poly(dimethylsiloxane)-cyclic olefin copolymer (PDMS-COC) devices that perform solid-phase extraction (SPE) and microchip electrophoresis (μCE) for automated PTB biomarker analysis. The PDMS control layer had a peristaltic pump and pneumatic valves for flow control, while the PDMS fluidic layer had five input reservoirs connected to microchannels and a μCE system. The COC layers had a reversed-phase octyl methacrylate porous polymer monolith for SPE and fluorescent labeling of PTB biomarkers. We determined μCE conditions for two PTB biomarkers, ferritin (Fer) and corticotropin-releasing factor (CRF). We used these integrated microfluidic devices to preconcentrate and purify off-chip-labeled Fer and CRF in an automated fashion. Finally, we performed a fully automated on-chip analysis of unlabeled PTB biomarkers, involving SPE, labeling, and μCE separation with 1 h total analysis time. These integrated systems have strong potential to be combined with upstream immunoaffinity extraction, offering a compact sample-to-answer biomarker analysis platform. Graphical abstract Pressure-actuated integrated microfluidic devices have been developed for automated solid-phase extraction, fluorescent labeling, and microchip electrophoresis of preterm birth biomarkers.

  4. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies

  5. Wavelet compression of multichannel ECG data by enhanced set partitioning in hierarchical trees algorithm.

    Science.gov (United States)

    Sharifahmadian, Ershad

    2006-01-01

    The set partitioning in hierarchical trees (SPIHT) algorithm is very effective and computationally simple technique for image and signal compression. Here the author modified the algorithm which provides even better performance than the SPIHT algorithm. The enhanced set partitioning in hierarchical trees (ESPIHT) algorithm has performance faster than the SPIHT algorithm. In addition, the proposed algorithm reduces the number of bits in a bit stream which is stored or transmitted. I applied it to compression of multichannel ECG data. Also, I presented a specific procedure based on the modified algorithm for more efficient compression of multichannel ECG data. This method employed on selected records from the MIT-BIH arrhythmia database. According to experiments, the proposed method attained the significant results regarding compression of multichannel ECG data. Furthermore, in order to compress one signal which is stored for a long time, the proposed multichannel compression method can be utilized efficiently.

  6. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  7. Dosimetry, instrumentation and exposure chambers for dc magnetic field studies

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1979-03-01

    The principal objective of this report is to describe in detail an exposure chamber that was developed at the Lawrence Berkeley Laboratory for automated, noninvasive studies of rodent physiology during exposure to high DC magnetic fields. A second objective is to discuss some of the unique instrumentation problems that must be overcome in order to record bioelectric signals from laboratory animals in the presence of a magnetic field. Finally, a description will be given of the various dosimetry techniques that can be employed for quantitation of magnetic field strength

  8. Continuous measurements of methane flux in two Japanese temperate forests based on the micrometeorological and chamber methods

    Science.gov (United States)

    Yoshikawa, K.; Ueyama, M.; Takagi, K.; Kominami, Y.

    2015-12-01

    Methane (CH4) budget in forest ecosystems have not been accurately quantified due to limited measurements and considerable spatiotemporal heterogeneity. In order to quantify CH4 fluxes at temperate forest at various spatiotemporal scales, we have continuously measured CH4 fluxes at two upland forests based on the micrometeorological hyperbolic relaxed eddy accumulation (HREA) and automated dynamic closed chamber methods.The measurements have been conducted at Teshio experimental forest (TSE) since September 2013 and Yamashiro forest meteorology research site (YMS) since November 2014. Three automated chambers were installed on each site. Our system can measure CH4 flux by the micrometeorological HREA, vertical concentration profile at four heights, and chamber measurements by a laser-based gas analyzer (FGGA-24r-EP, Los Gatos Research Inc., USA).Seasonal variations of canopy-scale CH4 fluxes were different in each site. CH4 was consumed during the summer, but was emitted during the fall and winter in TSE; consequently, the site acted as a net annual CH4 source. CH4 was steadily consumed during the winter, but CH4 fluxes fluctuated between absorption and emission during the spring and summer in YMS. YMS acted as a net annual CH4 sink. CH4 uptake at the canopy scale generally decreased with rising soil temperature and increased with drying condition for both sites. CH4 flux measured by most of chambers showed the consistent sensitivity examined for the canopy scale to the environmental variables. CH4 fluxes from a few chambers located at a wet condition were independent of variations in soil temperature and moisture at both sites. Magnitude of soil CH4 uptake was higher than the canopy-scale CH4 uptake. Our results showed that the canopy-scale CH4 fluxes were totally different with the plot-scale CH4 fluxes by chambers, suggesting the considerable spatial heterogeneity in CH4 flux at the temperate forests.

  9. Computationally Developed Sham Stimulation Protocol for Multichannel Desynchronizing Stimulation

    Directory of Open Access Journals (Sweden)

    Magteld Zeitler

    2018-05-01

    Full Text Available A characteristic pattern of abnormal brain activity is abnormally strong neuronal synchronization, as found in several brain disorders, such as tinnitus, Parkinson's disease, and epilepsy. As observed in several diseases, different therapeutic interventions may induce a placebo effect that may be strong and hinder reliable clinical evaluations. Hence, to distinguish between specific, neuromodulation-induced effects and unspecific, placebo effects, it is important to mimic the therapeutic procedure as precisely as possibly, thereby providing controls that actually lack specific effects. Coordinated Reset (CR stimulation has been developed to specifically counteract abnormally strong synchronization by desynchronization. CR is a spatio-temporally patterned multichannel stimulation which reduces the extent of coincident neuronal activity and aims at an anti-kindling, i.e., an unlearning of both synaptic connectivity and neuronal synchrony. Apart from acute desynchronizing effects, CR may cause sustained, long-lasting desynchronizing effects, as already demonstrated in pre-clinical and clinical proof of concept studies. In this computational study, we set out to computationally develop a sham stimulation protocol for multichannel desynchronizing stimulation. To this end, we compare acute effects and long-lasting effects of six different spatio-temporally patterned stimulation protocols, including three variants of CR, using a no-stimulation condition as additional control. This is to provide an inventory of different stimulation algorithms with similar fundamental stimulation parameters (e.g., mean stimulation rates but qualitatively different acute and/or long-lasting effects. Stimulation protocols sharing basic parameters, but inducing nevertheless completely different or even no acute effects and/or after-effects, might serve as controls to validate the specific effects of particular desynchronizing protocols such as CR. In particular, based on

  10. On the use of A PCA as a multichannel time analyzer

    International Nuclear Information System (INIS)

    Adib, M.; Abdelkawy, A.; Abuelela, M.; Habib, N.; Wahba, M.; Salama, F.

    1992-01-01

    PCA and PCA-11 software programmes have been used to utilize the operation of the nucleus personal computer analyzer PCA-8000 in its multichannel scaler (MCS) mode. The operating condition of PCA-8000 were selected to match the time-of-flight (TOF) spectrometer which is in operation at the ET-RR-1 reactor. The results of measuring the main parameters of PCA-8000 operating in its MCS mode showed that it can be successfully used as a multichannel time analyzer.5 fig

  11. Multichannel CdZnTe Gamma Ray Spectrometer

    International Nuclear Information System (INIS)

    Doty, F.P.; Lingren, C. L.; Apotovsky, B. A.; Brunsch, J.; Butler, J. F.; Collins, T.; Conwell, R.L.; Friesenhahn, S.; Gormley, J.; Pi, B.; Zhao, S.; Augustine, F.L.; Bennet, B. A.; Cross, E.; James, R. B.

    1998-01-01

    A 3 cm 3 multichannel gamma spectrometer for DOE applications is under development by Digirad Corporation. The device is based on a position sensitive detector packaged in a compact multi-chip module (MCM) with integrated readout circuitry. The modular, multichannel design will enable identification and quantitative analysis of radionuclides in extended sources, or sources containing low levels of activity. The MCM approach has the advantages that the modules are designed for imaging applications, and the sensitivity can be arbitrarily increased by increasing the number of pixels, i.e. adding modules to the instrument. For a high sensitivity probe, the outputs for each pixel can be corrected for gain and offset variations, and summed digitally. Single pixel results obtained with discrete low noise readout indicate energy resolution of 3 keV can be approached with currently available CdZnTe. The energy resolution demonstrated to date with MCMs for 511 keV gamma rays is 10 keV

  12. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  13. Automated EEG sleep staging in the term-age baby using a generative modelling approach

    Science.gov (United States)

    Pillay, Kirubin; Dereymaeker, Anneleen; Jansen, Katrien; Naulaers, Gunnar; Van Huffel, Sabine; De Vos, Maarten

    2018-06-01

    Objective. We develop a method for automated four-state sleep classification of preterm and term-born babies at term-age of 38-40 weeks postmenstrual age (the age since the last menstrual cycle of the mother) using multichannel electroencephalogram (EEG) recordings. At this critical age, EEG differentiates from broader quiet sleep (QS) and active sleep (AS) stages to four, more complex states, and the quality and timing of this differentiation is indicative of the level of brain development. However, existing methods for automated sleep classification remain focussed only on QS and AS sleep classification. Approach. EEG features were calculated from 16 EEG recordings, in 30 s epochs, and personalized feature scaling used to correct for some of the inter-recording variability, by standardizing each recording’s feature data using its mean and standard deviation. Hidden Markov models (HMMs) and Gaussian mixture models (GMMs) were trained, with the HMM incorporating knowledge of the sleep state transition probabilities. Performance of the GMM and HMM (with and without scaling) were compared, and Cohen’s kappa agreement calculated between the estimates and clinicians’ visual labels. Main results. For four-state classification, the HMM proved superior to the GMM. With the inclusion of personalized feature scaling, mean kappa (±standard deviation) was 0.62 (±0.16) compared to the GMM value of 0.55 (±0.15). Without feature scaling, kappas for the HMM and GMM dropped to 0.56 (±0.18) and 0.51 (±0.15), respectively. Significance. This is the first study to present a successful method for the automated staging of four states in term-age sleep using multichannel EEG. Results suggested a benefit in incorporating transition information using an HMM, and correcting for inter-recording variability through personalized feature scaling. Determining the timing and quality of these states are indicative of developmental delays in both preterm and term-born babies that may

  14. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  15. Multi-probe ionization chamber system for nuclear-generated plasma diagnostics

    International Nuclear Information System (INIS)

    Choi, W.Y.; Ellis, W.H.

    1990-01-01

    This paper reports on the pulsed ionization chamber (PIC) plasma diagnostic system used in studies of nuclear seeded plasma kinetics upgraded to increase the capabilities and extend the range of plasma parameter measurements to higher densities and temperatures. The PIC plasma diagnostic chamber has been provided with additional measurement features in the form of conductivity and Langmuir probes, while the overall experimental system has been fully automated, with computerized control, measurement, data acquisition and analysis by means of IEEE-488 (GPIB) bus control and data transfer protocols using a Macintosh series microcomputer. The design and use of a simple TTL switching system enables remote switching among the various GPIB instruments comprising the multi-probe plasma diagnostic system using software, without the need for a microprocessor. The new system will be used to extend the present study of nuclear generated plasma in He, Ar, Xe, fissionable UF 6 and other fluorine containing gases

  16. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  17. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  18. Non-Descemet’s stripping automated endothelial keratoplasty for bullous keratopathy secondary to iridoschisis

    Directory of Open Access Journals (Sweden)

    Minezaki T

    2013-07-01

    Full Text Available Teruumi Minezaki, Takaaki Hattori, Hayate Nakagawa, Shigeto Kumakura, Hiroshi GotoDepartment of Ophthalmology, Tokyo Medical University, Shinjukuku, Tokyo, JapanPurpose: To report a case of bullous keratopathy secondary to iridoschisis treated by non-Descemet's stripping automated endothelial keratoplasty (nDSAEK.Case report: A 79-year-old woman was referred to our hospital with loss of vision in the left eye. Slit lamp examination of her left eye showed a shallow anterior chamber with cataract and schisis in the inferior quadrant of iris stroma. Bullous keratopathy secondary to iridoschisis was diagnosed. Cataract surgery with iridectomy succeeded to deepen the anterior chamber and remove the floating iris leaf, although corneal edema remained. Four days later, nDSAEK was performed, which resolved corneal edema and restored visual acuity.Conclusion: The two-step surgery of cataract surgery plus iridectomy followed by nDSAEK may be an effective strategy for treating bullous keratopathy secondary to iridoschisis.Keywords: iridoschisis, bullous keratopathy, non-Descemet's stripping automated endothelial keratoplasty

  19. SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Syh, J; Patel, B; Zhang, J; Wu, H; Rosen, L [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2015-06-15

    Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. The CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.

  20. Research on Multichannel Test Device of Missile Fuze

    Directory of Open Access Journals (Sweden)

    Guoyong Zhen

    2014-05-01

    Full Text Available This paper introduces the design of multichannel acquisition circuit based on FPGA which samples and records the Doppler signals, ignition signal and the working condition of fuze security enforcement agencies of missile fuze in real-time in the test of high speed dynamic intersection. Furthermore, for the problem of increasing number of sample channel which causes the complexity of the multiplexer control, a general programmable channel switching method is proposed based on FPGA. In the method, FPGA is the control core, and using the internal ROM resource effectively simplifies the complexity of channel switch in the multichannel acquisition system. This paper analyzes the acquisition system design, and describes the design of hardware circuit and analog switch address coding in detail. The test result shows that the acquisition circuit meets the design requirements with high sampling precision and application value.

  1. A low-cost touchscreen operant chamber using a Raspberry Pi™.

    Science.gov (United States)

    O'Leary, James D; O'Leary, Olivia F; Cryan, John F; Nolan, Yvonne M

    2018-03-08

    The development of a touchscreen platform for rodent testing has allowed new methods for cognitive testing that have been back-translated from clinical assessment tools to preclinical animal models. This platform for cognitive assessment in animals is comparable to human neuropsychological tests such as those employed by the Cambridge Neuropsychological Test Automated Battery, and thus has several advantages compared to the standard maze apparatuses typically employed in rodent behavioral testing, such as the Morris water maze. These include improved translation of preclinical models, as well as high throughput and the automation of animal testing. However, these systems are relatively expensive, which can impede progress for researchers with limited resources. Here we describe a low-cost touchscreen operant chamber based on the single-board computer, Raspberry Pi TM , which is capable of performing tasks similar to those supported by current state-of-the-art systems. This system provides an affordable alternative for cognitive testing in a touchscreen operant paradigm for researchers with limited funding.

  2. Recent advances in Multi-Channel Algebraic Scattering

    International Nuclear Information System (INIS)

    Karataglidis, S.; Fraser, P. R.; Amos, K.; Canton, L.; Pisent, G.; Svenne, J. P.; Knijff, D. van der

    2011-01-01

    For coupled-channel descriptions of low-energy nucleon-induced interactions involving nuclei with particle-unstable exited states, it is necessary to include the widths of the target states. How those widths may affect the elastic scattering cross sections is examined within the framework of the Multi-Channel Algebraic Scattering (MCAS) method.

  3. Data processing for the multichannel pulse height analysis system ND-50/50, (1)

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1977-03-01

    The multichannel pulse height analysis system ND-50/50 manufactured by Nuclear Data Inc. consists of a 4096 channel pulse height analyzer and a small computer PDP-8/L (Digital Equipment Corporation). A conversational interpretive language, MACAL (Multichannel Analyzer CALculator) has been developed to analyze gamma-ray spectra in ND-50/50. It is a modification of the FOCAL (FOrmula CALculator) language of Digital Equipment Corporation. MACAL consists of imperative English commands and mathematical expressions, and has standard mathematical functions and functions for controlling the multichannel pulse height analyzer and I/O devices (high-speed reader, high-speed punch, and digital plotter). With MACAL, the following five programs were prepared : 1) program for controlling the multichannel pulse height analyzer and data handling, 2) program for automatically analyzing gamma-ray spectra obtained by germanium detectors, 3) program for automatically measuring characteristics of germanium detectors, 4) program for calculating the center energy of gamma-ray peaks, and 5) program for plotting the pulse height distribution and diagraming the results obtained with the programs. By combining the programs according to experimental purposes, the system can be highly effective. (auth.)

  4. Software for a multichannel acquisition card

    International Nuclear Information System (INIS)

    Arista Romeu, E. J.; Diaz Garcia, A.; Vela Morales, O.

    2013-01-01

    A software developed in C++ for a multichannel acquisition card is presented. The use of an acquisition add-on card with multiple channels is a suitable solution to substitute several instruments, allowing simultaneous acquisition with each channel. In this work, the limitations of a concrete hardware are discussed and also several different approaches have been suggested. Some preliminary results obtained in laboratory conditions are shown. (Author)

  5. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  6. Organization of a multichannel analyzer for gamma ray spectrometry

    International Nuclear Information System (INIS)

    Robinet, Genevieve

    1988-06-01

    This report describes the software organization of a medium scale multichannel analyzer for qualitative and quantitative measurements of the gamma rays emitted by radioactive samples. The first part reminds basis of radioactivity, principle of gamma ray detection, and data processing used for interpretation of a nuclear spectrum. The second part describes first the general organization of the software and then gives some details on interactivity, multidetector capabilites, and integration of complex algorithms for peak search and nuclide identification;problems encountered during the design phase are mentioned and solutions are given. Basic ideas are presented for further developments, such as expert system which should improve interpretation of the results. This present software has been integrated in a manufactured multichannel analyzer named 'POLYGAM NU416'. [fr

  7. Multi-channel grouping techniques for conducting reactor safety studies

    International Nuclear Information System (INIS)

    Waltar, A.E.; Wilburn, N.P.

    1975-01-01

    In conducting safety studies for postulated unprotected accidents in an LMFBR system, it is common practice to employ multi-channel coupled neutronics, thermal hydraulics computer programs such as SAS3A or MELT-III. The multichannel feature of such code systems is important if the natural fuel failure incoherencies and the resulting sodium void/fuel motion reactivity feedbacks--which have strong spatial variations--are to be properly modeled. Because of the large amounts of computer time associated with many channel runs, however, there is a strong incentive to conduct parametric studies with as few channels as possible. The paper presented is focused on methods successfully employed to accomplish this end for a study of the hypothetical unprotected transient overpower accident conducted for the FFTF

  8. 3m Vacuum Ultraviolet Spectrometer with Optical Multichannel Detector

    International Nuclear Information System (INIS)

    Martin, P.; Peraza, C.; Blanco, F.; Campos, J.

    1993-01-01

    This paper describes the design and the performance of a normal incidence vacuum ultraviolet spectrometer, for the 300-2400 A spectral range. It is provided with a multichannel detection system. The monochromator is original design and it has been built at CIEMAT. It is equipped with a 3 m concave holographic grating with 2400 grooves/mm. The multichannel detector consists of a windowless double microchannel plate / phosphor screen image intensifier, coupled by fiber optic to a 1024 elements self-scanning linear photodiode array. The output from the array is digitized by a 12-bit analog to digital converter and stored in a computer, for its later analysis. The necessary software to store and display data has been developed. (Author) 18 refs

  9. Multichannel interval timer

    International Nuclear Information System (INIS)

    Turko, B.T.

    1983-10-01

    A CAMAC based modular multichannel interval timer is described. The timer comprises twelve high resolution time digitizers with a common start enabling twelve independent stop inputs. Ten time ranges from 2.5 μs to 1.3 μs can be preset. Time can be read out in twelve 24-bit words either via CAMAC Crate Controller or an external FIFO register. LSB time calibration is 78.125 ps. An additional word reads out the operational status of twelve stop channels. The system consists of two modules. The analog module contains a reference clock and 13 analog time stretchers. The digital module contains counters, logic and interface circuits. The timer has an excellent differential linearity, thermal stability and crosstalk free performance

  10. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  11. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  12. Front-end electronics for multichannel semiconductor detector systems

    CERN Document Server

    Grybos, P

    2010-01-01

    Front-end electronics for multichannel semiconductor detektor systems Volume 08, EuCARD Editorial Series on Accelerator Science and Technology The monograph is devoted to many different aspects related to front-end electronics for semiconductor detector systems, namely: − designing and testing silicon position sensitive detectors for HEP experiments and X-ray imaging applications, − designing and testing of multichannel readout electronics for semiconductor detectors used in X-ray imaging applications, especially for noise minimization, fast signal processing, crosstalk reduction and good matching performance, − optimization of semiconductor detection systems in respect to the effects of radiation damage. The monograph is the result mainly of the author's experience in the above-mentioned areas and it is an attempt of a comprehensive presentation of issues related to the position sensitive detection system working in a single photon counting mode and intended to X-ray imaging applications. The structure...

  13. Closed-loop, multichannel experimentation using the open-source NeuroRighter electrophysiology platform

    Directory of Open Access Journals (Sweden)

    Jonathan Paul Newman

    2013-01-01

    Full Text Available Single neuron feedback control techniques, such as voltage clamp and dynamic clamp, have enabled numerous advances in our understanding of ion channels, electrochemical signaling, and neural dynamics. Although commercially available multichannel recording and stimulation systems are commonly used for studying neural processing at the network level, they provide little native support for real-time feedback. We developed the open-source NeuroRighter multichannel electrophysiology hardware and software platform for closed-loop multichannel control with a focus on accessibility and low cost. NeuroRighter allows 64 channels of stimulation and recording for around US $10,000, along with the ability to integrate with other software and hardware. Here, we present substantial enhancements to the NeuroRighter platform, including a redesigned desktop application, a new stimulation subsystem allowing arbitrary stimulation patterns, low-latency data servers for accessing data streams, and a new application programming interface (API for creating closed-loop protocols that can be inserted into NeuroRighter as plugin programs. This greatly simplifies the design of sophisticated real-time experiments without sacrificing the power and speed of a compiled programming language. Here we present a detailed description of NeuroRighter as a stand alone application, its plugin API, and an extensive set of case studies that highlight the system's abilities for conducting closed-loop, multichannel interfacing experiments.

  14. RAC-Multi: Reader Anti-Collision Algorithm for Multichannel Mobile RFID Networks

    Directory of Open Access Journals (Sweden)

    Kwangcheol Shin

    2009-12-01

    Full Text Available At present, RFID is installed on mobile devices such as mobile phones or PDAs and provides a means to obtain information about objects equipped with an RFID tag over a multi-channeled telecommunication networks. To use mobile RFIDs, reader collision problems should be addressed given that readers are continuously moving. Moreover, in a multichannel environment for mobile RFIDs, interference between adjacent channels should be considered. This work first defines a new concept of a reader collision problem between adjacent channels and then suggests a novel reader anti-collision algorithm for RFID readers that use multiple channels. To avoid interference with adjacent channels, the suggested algorithm separates data channels into odd and even numbered channels and allocates odd-numbered channels first to readers. It also sets an unused channel between the control channel and data channels to ensure that control messages and the signal of the adjacent channel experience no interference. Experimental results show that suggested algorithm shows throughput improvements ranging from 29% to 46% for tag identifications compared to the GENTLE reader anti-collision algorithm for multichannel RFID networks.

  15. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  16. Multichannel conformal blocks for scattering amplitudes

    Science.gov (United States)

    Belitsky, A. V.

    2018-05-01

    By performing resummation of small fermion-antifermion pairs within the pentagon form factor program to scattering amplitudes in planar N = 4 superYang-Mills theory, we construct multichannel conformal blocks within the flux-tube picture for N-sided NMHV polygons. This procedure is equivalent to summation of descendants of conformal primaries in the OPE framework. The resulting conformal partial waves are determined by multivariable hypergeometric series of Lauricella-Saran type.

  17. A versatile automated platform for micro-scale cell stimulation experiments.

    Science.gov (United States)

    Sinha, Anupama; Jebrail, Mais J; Kim, Hanyoup; Patel, Kamlesh D; Branda, Steven S

    2013-08-06

    Study of cells in culture (in vitro analysis) has provided important insight into complex biological systems. Conventional methods and equipment for in vitro analysis are well suited to study of large numbers of cells (≥ 10(5)) in milliliter-scale volumes (≥ 0.1 ml). However, there are many instances in which it is necessary or desirable to scale down culture size to reduce consumption of the cells of interest and/or reagents required for their culture, stimulation, or processing. Unfortunately, conventional approaches do not support precise and reproducible manipulation of micro-scale cultures, and the microfluidics-based automated systems currently available are too complex and specialized for routine use by most laboratories. To address this problem, we have developed a simple and versatile technology platform for automated culture, stimulation, and recovery of small populations of cells (100-2,000 cells) in micro-scale volumes (1-20 μl). The platform consists of a set of fibronectin-coated microcapillaries ("cell perfusion chambers"), within which micro-scale cultures are established, maintained, and stimulated; a digital microfluidics (DMF) device outfitted with "transfer" microcapillaries ("central hub"), which routes cells and reagents to and from the perfusion chambers; a high-precision syringe pump, which powers transport of materials between the perfusion chambers and the central hub; and an electronic interface that provides control over transport of materials, which is coordinated and automated via pre-determined scripts. As an example, we used the platform to facilitate study of transcriptional responses elicited in immune cells upon challenge with bacteria. Use of the platform enabled us to reduce consumption of cells and reagents, minimize experiment-to-experiment variability, and re-direct hands-on labor. Given the advantages that it confers, as well as its accessibility and versatility, our platform should find use in a wide variety of

  18. Automation of gamwave batch irradiator in Natal, South Africa

    International Nuclear Information System (INIS)

    Basson, J.K.; Basson, R.A.; Botha, J.

    1995-01-01

    High Energy Processing (HEPRO) has operated a Nordion JS 8200 Batch Irradiator for several years at Gamwave in Durban, South Africa. Product is loaded into aluminium totes and manually transported on trolleys into the irradiation chamber. Unirradiated totes are then exchanged with all the irradiated totes in the product pass mechanism, after which the source is raised and the batch irradiation process is started. Due to the inefficient Cobalt utilization experienced in this type of plant, it was decided to upgrade and automate the facility. This was done in what we believe is a simple and unique solution to the problem facing the future of such batch facilities. The design concept used for the Gamwave irradiator was based on irradiating product in carbons or bags of variable dimensions as per customer requirements. The intention was to convey product automatically in and out of the irradiation chamber eliminating the product change over downtime and thereby increasing source up utilization. Minor extensions were carried out to the Bioshield with the existing irradiator in full operation awaiting installation of the new source pass mechanism and conveyor system. Total plant shutdown for conversion to automation, including source reload and safety checks, was estimated to take ten days to fit the equipment. (author)

  19. Note: Design and investigation of a multichannel plasma-jet triggered gas switch.

    Science.gov (United States)

    Tie, Weihao; Liu, Xuandong; Zhang, Qiaogen; Liu, Shanhong

    2014-07-01

    We described the fabrication and testing of a multichannel plasma-jet triggered gas switch (MPJTGS). A novel six-channel annular micro-plasma-gun was embedded in the trigger electrode to generate multichannel plasma jets as a nanosecond trigger pulse arrived. The gas breakdown in multiple sites of the spark gap was induced and fixed around jet orifices by the plasma jets. We tested the multichannel discharge characteristics of the MPJTGS in two working modes with charge voltage of 50 kV, trigger voltage of +40 kV (25 ns rise time), and trigger energy of 240 J, 32 J, and 2 J, respectively, at different working coefficients. Results show that the average number of discharge channels increased as the trigger energy increased, and decreased as the working coefficient decreased. At a working coefficient of 87.1% and trigger energy of 240 J, the average number of discharge channels in Mode II could reach 4.1.

  20. Software filtering method to suppress spike pulse interference in multi-channel scaler

    International Nuclear Information System (INIS)

    Huang Shun; Zhao Xiuliang; Li Zhiqiang; Zhao Yanhui

    2008-01-01

    In the test on anti-jamming function of a multi-channel scaler, we found that the spike pulse interference on the second level counter caused by the motor start-stop operations brings a major count error. There are resolvable characteristics between effective signal and spike pulse interference, and multi-channel hardware filtering circuit is too huge and can't filter thoroughly, therefore we designed a software filtering method. In this method based on C8051F020 MCU, we dynamically store sampling values of one channel in only a one-byte variable and distinguish the rise-trail edge of a signal and spike pulse interference because of value changes of the variable. Test showed that the filtering software method can solve the error counting problem of the multi-channel scaler caused by the motor start-stop operations. The flow chart and source codes of the method were detailed in this paper. (authors)

  1. Multichannel perimetric alterations in systemic lupus erythematosus treated with hydroxychloroquine.

    Science.gov (United States)

    Piñero, David P; Monllor, Begoña; Camps, Vicente J; de Fez, Dolores

    Systemic lupus erythematosus (SLE) is a multiorgan autoimmune disease of unknown etiology with many clinical manifestations. We report the first case of SLE in which visual alterations were evaluated with multichannel perimetry. Some achromatic and color vision alterations may be present in SLE, especially when treated with hydroxychloroquine. The sensitivity losses detected in the chromatic channels in the central zone of the visual field were consistent with the results of the FM 100 Hue color test. Likewise, the multichannel perimetry detected sensitivity losses in the parafoveal area for both chromatic channels, especially for the blue-yellow. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  2. Drift chamber

    International Nuclear Information System (INIS)

    Inagaki, Yosuke

    1977-01-01

    Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)

  3. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  4. Efficient Numerical Solution of Coupled Radial Differential Equations in Multichannel Scattering Problems

    International Nuclear Information System (INIS)

    Houfek, Karel

    2008-01-01

    Numerical solution of coupled radial differential equations which are encountered in multichannel scattering problems is presented. Numerical approach is based on the combination of the exterior complex scaling method and the finite-elements method with the discrete variable representation. This method can be used not only to solve multichannel scattering problem but also to find bound states and resonance positions and widths directly by diagonalization of the corresponding complex scaled Hamiltonian. Efficiency and accuracy of this method is demonstrated on an analytically solvable two-channel problem.

  5. The design and implementation of a PC based multi-channel scaler system

    International Nuclear Information System (INIS)

    Wang Qiang; Chinese Academy of Sciences, Beijing; Jin Dapeng; Liu Zhen'an; Zhao Dixin

    2007-01-01

    A multi-channel scaler system is designed for the system check and status monitoring of the BESIII trigger system. It is composed of a PC, two PCI interface multi-channel scaler cards, the corresponding drivers and user programs. Total 64 signals can be scaled and monitored in real time. The scaled data are recorded locally and some of them are distributed to the online system. In this paper, the hardware structure, software development and long time running stability of the system are introduced. (authors)

  6. Disorder-induced topological transitions in multichannel Majorana wires

    NARCIS (Netherlands)

    Pekerten, B.; Teker, A.; Bozat, Ö.; Wimmer, M.T.; Adagideli, I

    2017-01-01

    In this work, we investigate the effect of disorder on the topological properties of multichannel superconductor nanowires. While the standard expectation is that the spectral gap is closed and opened at transitions that change the topological index of the wire, we show that the closing and

  7. The Art of Multi-channel Hypermedia Application Development

    NARCIS (Netherlands)

    Synodinos, Dionysios G.; Avgeriou, Paris

    2003-01-01

    The plethora of networked devices and platforms that continuously come to light, as well as the emergence of alternative ways to access the internet, have increased the demand for multi-channel access to hypermedia applications. Researchers and practitioners nowadays not only have to deal with the

  8. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  9. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  10. Multi-channel near infrared spectroradiometer

    International Nuclear Information System (INIS)

    Joseph, G.B.; Biddles, B.J.; D'silva, R.A.; Picot, A.J.; Ackerman, M.J.

    1988-01-01

    A multichannel spectroradiometer has been developed by Sira Ltd. for the study of rapidly varying events in the near infrared. The instrument is being used in the examination of gun flashes, rocket motor exhaust efflux analysis and ordnance or pyrotechnic flash studies. The spectral range of about 1.4 to 5.2 microns is covered in two bands with the first order dispersion from a pair of ruled blazed gratings being imaged onto a pair of detector arrays. Data may be logged at a rate of 1000 complete spectra per second

  11. Multichannel signal enhancement using a remote wireless microphone

    NARCIS (Netherlands)

    Bloemendal, Brian; Van De Laar, Jakob; Sommen, Piet

    2012-01-01

    A novel approach to multichannel signal enhancement is presented that exploits data from a remote wireless microphone (RWM). This RWM is placed near an interfering source and transmits only autocorrelation data of its observations to a host, i.e., not the entire signal. The host has access to the

  12. Classification of Multichannel ECG Signals Using a Cross-Distance Analysis

    National Research Council Canada - National Science Library

    Shahram, Morteza

    2001-01-01

    This paper presents a multi-stage algorithm for multi-channel ECG beat classification into normal and abnormal categories using a sequential beat clustering and a cross- distance analysis algorithm...

  13. Multi-channel electronically scanned cryogenic pressure sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Kruse, Nancy M. H. (Inventor)

    1995-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  14. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  15. AN ADAPTIVE MULTI-CHANNEL SPECTROELLIPSOMETER FOR ECOLOGICAL MONITORING

    Directory of Open Access Journals (Sweden)

    F. A. Mkrtchyan

    2012-09-01

    Full Text Available The creation of multichannel polarization optical instrumentation and use of spectroellipsometric technology are very important for the real-time ecological control of aquatic environment. Spectroellipsometric devices give us high precision of measurements. This report is aimed to describe: •A technology of combined use of spectroellipsometry and algorithms of identification and recognition that allowed the creation of a standard integral complex of instrumental, algorithmic, modular and software tools for the collection and processing of data on the aquatic environment quality with forecasting and decision - making functions. •A compact measuring - information multichannel spectroellipsometric system (device for monitoring the quality of aquatic environment, that is based on the combined use of spectroellipsometry and training, classification, and identification algorithms. This spectroellipsometric system will differ from modern foreign analogues by the use of a new and very promising method of ellipsometric measurements, an original element base of polarization optics and a complex mathematical approach to estimating the quality of a water object subjected to anthropogenic influence.Unlike foreign analogues, the system has no rotating polarization elements. This allows one to increase the signal-to-noise ratio and the long-term stability of measurements, to simplify and reduce the price of multichannel spectroellipsometers. The system will be trainable to the recognition of the pollutants of aquatic environment. A spectroellipsometer in laboratories of V.A. Kotelnikov's Institute of Radioengineering and Electronics, Russian Academy of Sciences is designed for in-situ real time measurements of spectra of ellipsometric parameters Psi and Delta with consequent changeover to spectra of transmitted and reflected signal from water media in frames of used physical model of water environment.

  16. Simulation study on vertically distributed multi-channel tangential interferometry for KSTAR

    International Nuclear Information System (INIS)

    Nam, Y U; Juhn, J W

    2012-01-01

    Interferometry is powerful and reliable diagnostics which measures line-integrated electron density. Since this technique only measures an averaged value over whole probing line, a multi-channel scheme is used for an analysis for spatial distribution and variation of electron density. Typical setups of the multi-channel measurement are schemes of radially distributed vertical lines, vertically distributed horizontal lines and horizontally distributed tangential lines. In Korea Superconducting Tokamak Advanced Research, a vertically distributed multi-channel tangential interferometry is planned instead of above typical schemes due to limitation of complex in-vessel geometry and narrow diagnostics port through cryostat. Total 5-channels will be vertically placed as symmetric with the mid-plain. One of the characteristic features of the vertically distributed channels is that each channel is viewing different poloidal angle, while the horizontally distributed channels are viewing different toroidal angle. This scheme also can be used on an investigation of the up-down asymmetry and the vertical oscillation of plasma. Simulation has been performed and the result will be discussed to verify the possibility and the estimated effectiveness of the scheme on this paper.

  17. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  18. A high-speed interface for multi-channel analyzer

    International Nuclear Information System (INIS)

    Shen Ji; Zheng Zhong; Qiao Chong; Chen Ziyu; Ye Yunxiu; Ye Zhenyu

    2003-01-01

    This paper presents a high-speed computer interface for multi-channel analyzer based on DMA technique. Its essential principle and operating procedure are introduced. By the detecting of γ spectrum of 137 Cs with the interface, it's proved that the interface can meet the requirements of high-speed data acquisition

  19. Compact multichannel MEMS based spectrometer for FBG sensing

    DEFF Research Database (Denmark)

    Ganziy, Denis; Rose, Bjarke; Bang, Ole

    2017-01-01

    We propose a novel type of compact multichannel MEMS based spectrometer, where we replace the linear detector with a Digital Micromirror Device (DMD). The DMD is typically cheaper and has better pixel sampling than an InGaAs detector used in the 1550 nm range, which leads to cost reduction...

  20. A lossless multichannel bio-signal compression based on low-complexity joint coding scheme for portable medical devices.

    Science.gov (United States)

    Kim, Dong-Sun; Kwon, Jin-San

    2014-09-18

    Research on real-time health systems have received great attention during recent years and the needs of high-quality personal multichannel medical signal compression for personal medical product applications are increasing. The international MPEG-4 audio lossless coding (ALS) standard supports a joint channel-coding scheme for improving compression performance of multichannel signals and it is very efficient compression method for multi-channel biosignals. However, the computational complexity of such a multichannel coding scheme is significantly greater than that of other lossless audio encoders. In this paper, we present a multichannel hardware encoder based on a low-complexity joint-coding technique and shared multiplier scheme for portable devices. A joint-coding decision method and a reference channel selection scheme are modified for a low-complexity joint coder. The proposed joint coding decision method determines the optimized joint-coding operation based on the relationship between the cross correlation of residual signals and the compression ratio. The reference channel selection is designed to select a channel for the entropy coding of the joint coding. The hardware encoder operates at a 40 MHz clock frequency and supports two-channel parallel encoding for the multichannel monitoring system. Experimental results show that the compression ratio increases by 0.06%, whereas the computational complexity decreases by 20.72% compared to the MPEG-4 ALS reference software encoder. In addition, the compression ratio increases by about 11.92%, compared to the single channel based bio-signal lossless data compressor.

  1. Multiple scattering theory for non-local and multichannel potentials

    Czech Academy of Sciences Publication Activity Database

    Natoli, C.R.; Krüger, P.; Hatada, K.; Hayakawa, K.; Sébilleau, D.; Šipr, Ondřej

    2012-01-01

    Roč. 24, č. 36 (2012), s. 1-20 ISSN 0953-8984 Institutional research plan: CEZ:AV0Z10100521 Keywords : multichannel scattering * correlation s * density matrix Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.355, year: 2012

  2. Multichannel optical mapping: investigation of depth information

    Science.gov (United States)

    Sase, Ichiro; Eda, Hideo; Seiyama, Akitoshi; Tanabe, Hiroki C.; Takatsuki, Akira; Yanagida, Toshio

    2001-06-01

    Near infrared (NIR) light has become a powerful tool for non-invasive imaging of human brain activity. Many systems have been developed to capture the changes in regional brain blood flow and hemoglobin oxygenation, which occur in the human cortex in response to neural activity. We have developed a multi-channel reflectance imaging system, which can be used as a `mapping device' and also as a `multi-channel spectrophotometer'. In the present study, we visualized changes in the hemodynamics of the human occipital region in multiple ways. (1) Stimulating left and right primary visual cortex independently by showing sector shaped checkerboards sequentially over the contralateral visual field, resulted in corresponding changes in the hemodynamics observed by `mapping' measurement. (2) Simultaneous measurement of functional-MRI and NIR (changes in total hemoglobin) during visual stimulation showed good spatial and temporal correlation with each other. (3) Placing multiple channels densely over the occipital region demonstrated spatial patterns more precisely, and depth information was also acquired by placing each pair of illumination and detection fibers at various distances. These results indicate that optical method can provide data for 3D analysis of human brain functions.

  3. Measurements of CO2 exchange with an automated chamber system throughout the year: challenges in measuring nighttime respiration on porous peat soil

    Science.gov (United States)

    Koskinen, M.; Minkkinen, K.; Ojanen, P.; Kämäräinen, M.; Laurila, T.; Lohila, A.

    2013-08-01

    We built an automatic chamber system to measure greehouse gas (GHG) exchange in forested peatland ecosystems. We aimed to build a system robust enough which would work throughout the year and could measure through a changing snowpackin addition to producing annual GHG fluxes by integrating the measurements without the need of using models. The system worked rather well throughout the year, but it was not service free. Gap filling of data was still necessary. We observed problems in carbon dioxide (CO2) flux estimation during calm summer nights, when a CO2 concentration gradient from soil/moss system to atmosphere builds up. Chambers greatly overestimated the nighttime respiration. This was due to the disturbance caused by the chamber to the soil-moss CO2 gradient and consequent initial pulse of CO2 to the chamber headspace. We tested different flux calculation and measurement methods to solve this problem. The estimated flux was strongly dependent on (1) the type of the fit (linear and polynomial), (2) the starting point of the fit after closing the chamber, (3) the length of the fit, (4) the speed of the fan mixing the air inside the chamber, and (5) atmospheric turbulence (friction velocity, u*). The best fitting method (the most robust, least random variation) was linear fitting with the period of 120-240 s after chamber closure. Furthermore, the fan should be adjusted to spin at minimum speed to avoid the pulse-effect, but it should be kept on to ensure mixing. If nighttime problems cannot be solved, emissions can be estimated using daytime data from opaque chambers.

  4. Behind the web store: the organisational and spatial evolution of multichannel retailing in Toronto

    OpenAIRE

    Andrew Currah

    2002-01-01

    In this paper I address two issues of general relevance to contemporary debates in economic geography: first, the organisational and spatial implications of new information technologies for the economic landscape; and, second, the enduring role of place to digital capitalism. Specifically, I examine the organisational evolution of multichannel retailing in Toronto from a geographical perspective. Bricks-and-mortar retailers are increasingly pursuing a multichannel strategy by operating an Int...

  5. Automation of the reading of an ionization chamber: study and design of a data transfer system

    International Nuclear Information System (INIS)

    RANDRIAMAHOLISOA, C.O.

    1999-01-01

    Management of information obtained through ionization chamber, type of detector the most employed in centers or institutions using ionizing radiation machines and radioactive sources, is done manually because data are fed into computers from keyboard. This procedure presents hazards of loss and bad transcription of information. A more practical way of getting over this handicap is the setting up of a system that transfers data from ionization chamber into computer. Thereafter, it will be easier for the user to adjust his data processing software to the system underconsideration. This system, even though not directly designed to process data, that being a specific task of each user, is constituted of an electronic aspect which plays the interface part between them. It takes account parameters having relevance to the quality and the quantity of information put out by the detector [fr

  6. Retail business model transformation in multichannel environment

    OpenAIRE

    Chapagain, B. (Bimala)

    2015-01-01

    Abstract With the advent of internet and e-commerce, the way of carrying out business and transactions has changed to a great extent. Consumers are continuously changing the way they do shopping and this has forced retail business to transform their traditional brick and mortar into adopting multi-channel business models. Retailing is one of the most dynamic and competitive areas of business organization. Effective marketin...

  7. RANDOMNUMBERS, Random Number Sequence Generated from Gas Ionisation Chamber Data

    International Nuclear Information System (INIS)

    Frigerio, N.A.; Sanathanan, L.P.; Morley, M.; Tyler, S.A.; Clark, N.A.; Wang, J.

    1989-01-01

    1 - Description of problem or function: RANDOM NUMBERS is a data collection of almost 2.7 million 31-bit random numbers generated by using a high resolution gas ionization detector chamber in conjunction with a 4096-channel multichannel analyzer to record the radioactive decay of alpha particles from a U-235 source. The signals from the decaying alpha particles were fed to the 4096-channel analyzer, and for each channel the frequency of signals registered in a 20,000-microsecond interval was recorded. The parity bits of these frequency counts, 0 for an even count and 1 for and odd count, were then assembled in sequence to form 31-bit random numbers and transcribed onto magnetic tape. This cycle was repeated to obtain the random numbers. 2 - Method of solution: The frequency distribution of counts from the device conforms to the Brockwell-Moyal distribution which takes into account the dead time of the counter. The count data were analyzed and tests for randomness on a sample indicate that the device is a highly reliable source of truly random numbers. 3 - Restrictions on the complexity of the problem: The RANDOM NUMBERS tape contains 2,669,568 31-bit numbers

  8. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  9. E-Fulfillment and Multi-Channel Distribution – A Review

    NARCIS (Netherlands)

    N.A.H. Agatz (Niels); M. Fleischmann (Moritz); J.A.E.E. van Nunen (Jo)

    2006-01-01

    textabstractThis review addresses the specific supply chain management issues of Internet fulfillment in a multi-channel environment. It provides a systematic overview of managerial planning tasks and reviews corresponding quantitative models. In this way, we aim to enhance the understanding of

  10. On iteration-separable method on the multichannel scattering theory

    International Nuclear Information System (INIS)

    Zubarev, A.L.; Ivlieva, I.N.; Podkopaev, A.P.

    1975-01-01

    The iteration-separable method for solving the equations of the Lippman-Schwinger type is suggested. Exponential convergency of the method of proven. Numerical convergency is clarified on the e + H scattering. Application of the method to the theory of multichannel scattering is formulated

  11. Automation of the helium jet transport system for nuclear recoil products; Automacao do sistema de transporte de nucleos de recuo por jato de helio

    Energy Technology Data Exchange (ETDEWEB)

    Bellido, Luis F.; Pedrosa, Paulo S

    1996-09-01

    A computer code and an interface hardware to automate the acquisition data and the sample changer in a helium jet transport system of recoil nucleus was developed for an IBM or compatible personal microcomputer. The software works with a Spectrum-ACE/ADCAM ORTEC`s multichannel analysers and the interface card uses the 03EFh port to command the sample changer. This system allows to measure, by gamma spectrometry, radionuclides with half-lives of order of seconds produced from nuclear reactions. (author) 3 refs.

  12. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  13. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  14. Automated gamma spectrometry and data analysis on radiometric neutron dosimeters

    International Nuclear Information System (INIS)

    Matsumoto, W.Y.

    1983-01-01

    An automated gamma-ray spectrometry system was designed and implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Laboratory (HEDL) to analyze radiometric neutron dosimeters. Unattended, automatic, 24 hour/day, 7 day/week operation with online data analysis and mainframe-computer compatible magnetic tape output are system features. The system was used to analyze most of the 4000-plus radiometric monitors (RM's) from extensive reactor characterization tests during startup and initial operation of th Fast Flux Test Facility (FFTF). The FFTF, operated by HEDL for the Department of Energy, incorporates a 400 MW(th) sodium-cooled fast reactor. Aumomated system hardware consists of a high purity germanium detector, a computerized multichannel analyzer data acquisition system (Nuclear Data, Inc. Model 6620) with two dual 2.5 Mbyte magnetic disk drives plus two 10.5 inch reel magnetic tape units for mass storage of programs/data and an automated Sample Changer-Positioner (ASC-P) run with a programmable controller. The ASC-P has a 200 sample capacity and 12 calibrated counting (analysis) positions ranging from 6 inches (15 cm) to more than 20 feet (6.1 m) from the detector. The system software was programmed in Fortran at HEDL, except for the Nuclear Data, Inc. Peak Search and Analysis Program and Disk Operating System (MIDAS+)

  15. Centrifugal LabTube platform for fully automated DNA purification and LAMP amplification based on an integrated, low-cost heating system.

    Science.gov (United States)

    Hoehl, Melanie M; Weißert, Michael; Dannenberg, Arne; Nesch, Thomas; Paust, Nils; von Stetten, Felix; Zengerle, Roland; Slocum, Alexander H; Steigert, Juergen

    2014-06-01

    This paper introduces a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA purification platform (LabTube). We demonstrate LabTube-based fully automated DNA purification of as low as 100 cell-equivalents of verotoxin-producing Escherichia coli (VTEC) in water, milk and apple juice in a laboratory centrifuge, followed by integrated and automated LAMP amplification with a reduction of hands-on time from 45 to 1 min. The heating system consists of two parallel SMD thick film resistors and a NTC as heating and temperature sensing elements. They are driven by a 3 V battery and controlled by a microcontroller. The LAMP reagents are stored in the elution chamber and the amplification starts immediately after the eluate is purged into the chamber. The LabTube, including a microcontroller-based heating system, demonstrates contamination-free and automated sample-to-answer nucleic acid testing within a laboratory centrifuge. The heating system can be easily parallelized within one LabTube and it is deployable for a variety of heating and electrical applications.

  16. Fibercore AstroGain fiber: multichannel erbium doped fibers for optical space communications

    Science.gov (United States)

    Hill, Mark; Gray, Rebecca; Hankey, Judith; Gillooly, Andy

    2014-03-01

    Fibercore have developed AstroGainTM fiber optimized for multichannel amplifiers used in optical satellite communications and control. The fiber has been designed to take full advantage of the photo-annealing effect that results from pumping in the 980nm region. The proprietary trivalent structure of the core matrix allows optimum recovery following radiation damage to the fiber, whilst also providing a market leading Erbium Doped Fiber Amplifier (EDFA) efficiency. Direct measurements have been taken of amplifier efficiency in a multichannel assembly, which show an effective photo-annealing recovery of up to 100% of the radiation induced attenuation through excitation of point defects.

  17. Occupant feedback based model predictive control for thermal comfort and energy optimization: A chamber experimental evaluation

    International Nuclear Information System (INIS)

    Chen, Xiao; Wang, Qian; Srebric, Jelena

    2016-01-01

    Highlights: • This study evaluates an occupant-feedback driven Model Predictive Controller (MPC). • The MPC adjusts indoor temperature based on a dynamic thermal sensation (DTS) model. • A chamber model for predicting chamber air temperature is developed and validated. • Experiments show that MPC using DTS performs better than using Predicted Mean Vote. - Abstract: In current centralized building climate control, occupants do not have much opportunity to intervene the automated control system. This study explores the benefit of using thermal comfort feedback from occupants in the model predictive control (MPC) design based on a novel dynamic thermal sensation (DTS) model. This DTS model based MPC was evaluated in chamber experiments. A hierarchical structure for thermal control was adopted in the chamber experiments. At the high level, an MPC controller calculates the optimal supply air temperature of the chamber heating, ventilation, and air conditioning (HVAC) system, using the feedback of occupants’ votes on thermal sensation. At the low level, the actual supply air temperature is controlled by the chiller/heater using a PI control to achieve the optimal set point. This DTS-based MPC was also compared to an MPC designed based on the Predicted Mean Vote (PMV) model for thermal sensation. The experiment results demonstrated that the DTS-based MPC using occupant feedback allows significant energy saving while maintaining occupant thermal comfort compared to the PMV-based MPC.

  18. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    Science.gov (United States)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  19. Phase sensitive multichannel OCT

    International Nuclear Information System (INIS)

    Trasischker, W.

    2015-01-01

    The main aim of this thesis was to develop and improve phase sensitive, multichannel methods for optical coherence tomography (OCT) using light in the 840 nm and 1040 nm regime. Conventional OCT provides purely structural information by illuminating the sample by one beam and recording the backscattered signal with one detection channel. Combination of this approach with a raster scan enables the acquisition of 2D and 3D structural information with a resolution in the micrometer regime. However, sometimes additional image contrast or information is desired. Amongst other approaches, this can be provided by a phase sensitive analysis of the interference pattern. Combining phase sensitivity with the illumination of the sample by more than one beam and/or by recording the data using more than one data acquisition channel allows for even more enhanced imaging. While phase sensitive OCT gives access to additional contrast and information, multichannel OCT can provide higher imaging speed, scan eld size and exible dierential measurements. Amongst the dierential, phase sensitive approaches, Doppler OCT (DOCT) and polarization sensitive OCT (PS-OCT) are two of the most promising OCT modalities. While the former targets information on the movement of backscattering particles, the latter measures alterations of the polarization state of the light induced by the sample. Both techniques provide additional image contrast and are, due to the non-invasive and fast character of OCT, well suited for in vivo imaging of the human eye. In the course of this thesis, two dierent multichannel, phase sensitive OCT systems will be presented. First, a D-OCT system with three dierent sampling beams is described. With a central wavelength of 840 nm these three beams are emitted by three individual laser sources. This eectively eliminates any cross talk and provides the full depth range for each channel. Furthermore, by illuminating the sample from three dierent directions, the absolute

  20. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  1. A multichannel frequency response analyser for impedance spectroscopy on power sources

    Directory of Open Access Journals (Sweden)

    DANIEL J. L. BRETT

    2013-06-01

    Full Text Available A low-cost multi-channel frequency response analyser (FRA has been developed based on a DAQ (data acquisition/LabVIEW interface. The system has been tested for electric and electrochemical impedance measurements. This novel association of hardware and software demonstrated performance comparable to a commercial potentiostat / FRA for passive electric circuits. The software has multichannel capabilities with minimal phase shift for 5 channels when operated below 3 kHz. When applied in active (galvanostatic mode in conjunction with a commercial electronic load (by discharging a lead acid battery at 1.5 A the performance was fit for purpose, providing electrochemical information to characterize the performance of the power source.

  2. Automated profiling of individual cell-cell interactions from high-throughput time-lapse imaging microscopy in nanowell grids (TIMING).

    Science.gov (United States)

    Merouane, Amine; Rey-Villamizar, Nicolas; Lu, Yanbin; Liadi, Ivan; Romain, Gabrielle; Lu, Jennifer; Singh, Harjeet; Cooper, Laurence J N; Varadarajan, Navin; Roysam, Badrinath

    2015-10-01

    There is a need for effective automated methods for profiling dynamic cell-cell interactions with single-cell resolution from high-throughput time-lapse imaging data, especially, the interactions between immune effector cells and tumor cells in adoptive immunotherapy. Fluorescently labeled human T cells, natural killer cells (NK), and various target cells (NALM6, K562, EL4) were co-incubated on polydimethylsiloxane arrays of sub-nanoliter wells (nanowells), and imaged using multi-channel time-lapse microscopy. The proposed cell segmentation and tracking algorithms account for cell variability and exploit the nanowell confinement property to increase the yield of correctly analyzed nanowells from 45% (existing algorithms) to 98% for wells containing one effector and a single target, enabling automated quantification of cell locations, morphologies, movements, interactions, and deaths without the need for manual proofreading. Automated analysis of recordings from 12 different experiments demonstrated automated nanowell delineation accuracy >99%, automated cell segmentation accuracy >95%, and automated cell tracking accuracy of 90%, with default parameters, despite variations in illumination, staining, imaging noise, cell morphology, and cell clustering. An example analysis revealed that NK cells efficiently discriminate between live and dead targets by altering the duration of conjugation. The data also demonstrated that cytotoxic cells display higher motility than non-killers, both before and during contact. broysam@central.uh.edu or nvaradar@central.uh.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. A fully algebraic solution for multichannel scattering of neutrons from nuclei

    International Nuclear Information System (INIS)

    Amos, K.

    2001-01-01

    In this report I give the prescription by which an algebraic solution can be found for multichannel scattering of neutrons from nuclei. The theory, developed by the Padova group, is built upon the work of Rawitscher and Delic. The approach is predicated upon finite rank representations of realistic interaction potentials and the properties of scattering matrices for separable Schrodinger interactions. The Padova approach starts with a solvable auxiliary Sturmian function (Weinberg state) problem from which a first generation set of Sturmians are defined. That basis set is formed by choosing a solvable problem at a fixed negative energy, and thereby those Sturmians can be specified in closed analytic form. Second generation Sturmians built upon the interaction potential matrices for a multichannel scattering problem of interest then can be found as linear combinations of the first generation set. The expansion coefficients result from a matrix diagonalization process. The scheme enables an expansion (usually truncated to finite rank for convenience) of the interaction potential in terms of those second generation Sturmians and in the form of a sum of separable interactions. The analytic properties of the scattering matrix from a separable Schroedinger potential gives the means by which a full algebraic solution of the multichannel scattering problem can be realized. (author)

  4. The effect of hypobaric hypoxia on multichannel EEG signal complexity.

    Science.gov (United States)

    Papadelis, Christos; Kourtidou-Papadeli, Chrysoula; Bamidis, Panagiotis D; Maglaveras, Nikos; Pappas, Konstantinos

    2007-01-01

    The objective of this study was the development and evaluation of nonlinear electroencephalography parameters which assess hypoxia-induced EEG alterations, and describe the temporal characteristics of different hypoxic levels' residual effect upon the brain electrical activity. Multichannel EEG, pO2, pCO2, ECG, and respiration measurements were recorded from 10 subjects exposed to three experimental conditions (100% oxygen, hypoxia, recovery) at three-levels of reduced barometric pressure. The mean spectral power of EEG under each session and altitude were estimated for the standard bands. Approximate Entropy (ApEn) of EEG segments was calculated, and the ApEn's time-courses were smoothed by a moving average filter. On the smoothed diagrams, parameters were defined. A significant increase in total power and power of theta and alpha bands was observed during hypoxia. Visual interpretation of ApEn time-courses revealed a characteristic pattern (decreasing during hypoxia and recovering after oxygen re-administration). The introduced qEEG parameters S1 and K1 distinguished successfully the three hypoxic conditions. The introduced parameters based on ApEn time-courses are assessing reliably and effectively the different hypoxic levels. ApEn decrease may be explained by neurons' functional isolation due to hypoxia since decreased complexity corresponds to greater autonomy of components, although this interpretation should be further supported by electrocorticographic animal studies. The introduced qEEG parameters seem to be appropriate for assessing the hypoxia-related neurophysiological state of patients in the hyperbaric chambers in the treatment of decompression sickness, carbon dioxide poisoning, and mountaineering.

  5. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  6. Effect of flow rate distribution at the inlet on hydrodynamic mixing in narrow rectangular multi-channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Chen Bingde; Wang Xiaojun

    2008-01-01

    Flow and heat transfer in the narrow rectangular multi-channel is widely en- countered in the engineering application, hydrodynamic mixing in the narrow rectangular multi-channel is one of the important concerns. With the help of the Computational Fluid Dynamics code CFX, the effect of flow rate distribution of the main channel at the inlet on hydrodynamic mixing in the narrow rectangular multi-channel is numerical simulated. The results show that the flow rate distributions at the inlet have a great effect on hydrodynamics mixing in multi-channel, the flow rate in the main channel doesn't change with increasing the axial mixing section when the average flow rate at the inlet is set. Hydrodynamic mixing will arise in the mixing section when the different ratio of the flow rate distribution at the inlet is set, and hydrodynamic mixing increases with the difference of the flow rate distribution at the inlet increase. The trend of the flow rate distribution of the main channel is consistent during the whole axial mixing section, and hydrodynamic mixing in former 4 mixing section is obvious. (authors)

  7. Robust, highly customizable, and economical multi-channel electrode for chronic multi-unit recording in behaving animals.

    Science.gov (United States)

    Tateyama, Yukina; Oyama, Kei; Shiraishi, Masaru; Iijima, Toshio; Tsutsui, Ken-Ichiro

    2017-12-01

    Multi-unit recording has been one of the most widely used techniques to investigate the correlation between multiple neuronal activities and behavior. However, a common problem of currently used multi-channel electrodes is their physical weakness. In this study, we developed a novel multi-channel electrode with sufficient physical strength to penetrate a thickened dura mater. This electrode consists of low-cost materials and is easily fabricated, and it enables recording without removing dura mater, thereby reducing the risk of inflammation, infection, or brain herniation. The low-cost multi-channel electrode developed in this study would be a useful tool for chronic recording in behaving animals. Copyright © 2017. Published by Elsevier B.V.

  8. Multi-channel spintronic transistor design based on magnetoelectric barriers and spin-orbital effects

    International Nuclear Information System (INIS)

    Fujita, T; Jalil, M B A; Tan, S G

    2008-01-01

    We present a spin transistor design based on spin-orbital interactions in a two-dimensional electron gas, with magnetic barriers induced by a patterned ferromagnetic gate. The proposed device overcomes certain shortcomings of previous spin transistor designs such as long device length and degradation of conductance modulation for multi-channel transport. The robustness of our device for multi-channel transport is unique in spin transistor designs based on spin-orbit coupling. The device is more practical in fabrication and experimental respects compared to previously conceived single-mode spin transistors

  9. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. Multi-channel temperature measurement system for automotive battery stack

    Science.gov (United States)

    Lewczuk, Radoslaw; Wojtkowski, Wojciech

    2017-08-01

    A multi-channel temperature measurement system for monitoring of automotive battery stack is presented in the paper. The presented system is a complete battery temperature measuring system for hybrid / electric vehicles that incorporates multi-channel temperature measurements with digital temperature sensors communicating through 1-Wire buses, individual 1-Wire bus for each sensor for parallel computing (parallel measurements instead of sequential), FPGA device which collects data from sensors and translates it for CAN bus frames. CAN bus is incorporated for communication with car Battery Management System and uses additional CAN bus controller which communicates with FPGA device through SPI bus. The described system can parallel measure up to 12 temperatures but can be easily extended in the future in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.

  12. Automation of radiation dosimetry using PTW dosemeter and LabVIEWTM

    International Nuclear Information System (INIS)

    Weiss, C.; Al-Frouh, K.; Anjak, O.

    2011-01-01

    Automation of UNIDOS 'Dosemeter' using personal computer (PC) is discussed in this paper. In order to save time and eliminate human operation errors during the radiation dosimetry, suitable software, using LabVIEW TM graphical programming language, was written to automate and facilitate the processes of measurements, analysis and data storage. The software calculates the calibration factor of the ionization chamber in terms of air kerma or absorbed dose to water according to IAEA dosimetry protocols. It also has the ability to print a calibration certificate. The obtained results using this software are found to be more reliable and flexible than those obtained by manual methods previously employed. Using LabVIEW TM as a development tool is extremely convenient to make things easier when software modifications and improvements are needed.

  13. Very Fast Algorithms and Detection Performance of Multi-Channel and 2-D Parametric Adaptive Matched Filters for Airborne Radar

    National Research Council Canada - National Science Library

    Marple, Jr., S. L; Corbell, Phillip M; Rangaswamy, Muralidhar

    2007-01-01

    ...) detection statistics under exactly known covariance (the clairvoyant case). Improved versions of the two original multichannel PAMF algorithms, one new multichannel PAMF algorithm, and a new two-dimensional (2D) PAMF algorithm...

  14. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  15. Measurements of CO2 exchange with an automated chamber system throughout the year: challenges in measuring night-time respiration on porous peat soil

    Directory of Open Access Journals (Sweden)

    M. Koskinen

    2014-01-01

    Full Text Available We built an automatic chamber system to measure greenhouse gas (GHG exchange in forested peatland ecosystems. We aimed to build a system robust enough which would work throughout the year and could measure through a changing snowpack in addition to producing annual GHG fluxes by integrating the measurements without the need of using models. The system worked rather well throughout the year, but it was not service free. Gap filling of data was still necessary. We observed problems in carbon dioxide (CO2 respiration flux estimation during calm summer nights, when a CO2 concentration gradient from soil/moss system to atmosphere builds up. Chambers greatly overestimated the night-time respiration. This was due to the disturbance caused by the chamber to the soil-moss CO2 gradient and consequent initial pulse of CO2 to the chamber headspace. We tested different flux calculation and measurement methods to solve this problem. The estimated flux was strongly dependent on (1 the starting point of the fit after closing the chamber, (2 the length of the fit, (3 the type of the fit (linear and polynomial, (4 the speed of the fan mixing the air inside the chamber, and (5 atmospheric turbulence (friction velocity, u*. The best fitting method (the most robust, least random variation for respiration measurements on our sites was linear fitting with the period of 120–240 s after chamber closure. Furthermore, the fan should be adjusted to spin at minimum speed to avoid the pulse-effect, but it should be kept on to ensure mixing. If night-time problems cannot be solved, emissions can be estimated using daytime data from opaque chambers.

  16. Measurements of CO2 exchange with an automated chamber system throughout the year: challenges in measuring night-time respiration on porous peat soil

    Science.gov (United States)

    Koskinen, M.; Minkkinen, K.; Ojanen, P.; Kämäräinen, M.; Laurila, T.; Lohila, A.

    2014-01-01

    We built an automatic chamber system to measure greenhouse gas (GHG) exchange in forested peatland ecosystems. We aimed to build a system robust enough which would work throughout the year and could measure through a changing snowpack in addition to producing annual GHG fluxes by integrating the measurements without the need of using models. The system worked rather well throughout the year, but it was not service free. Gap filling of data was still necessary. We observed problems in carbon dioxide (CO2) respiration flux estimation during calm summer nights, when a CO2 concentration gradient from soil/moss system to atmosphere builds up. Chambers greatly overestimated the night-time respiration. This was due to the disturbance caused by the chamber to the soil-moss CO2 gradient and consequent initial pulse of CO2 to the chamber headspace. We tested different flux calculation and measurement methods to solve this problem. The estimated flux was strongly dependent on (1) the starting point of the fit after closing the chamber, (2) the length of the fit, (3) the type of the fit (linear and polynomial), (4) the speed of the fan mixing the air inside the chamber, and (5) atmospheric turbulence (friction velocity, u*). The best fitting method (the most robust, least random variation) for respiration measurements on our sites was linear fitting with the period of 120-240 s after chamber closure. Furthermore, the fan should be adjusted to spin at minimum speed to avoid the pulse-effect, but it should be kept on to ensure mixing. If night-time problems cannot be solved, emissions can be estimated using daytime data from opaque chambers.

  17. Gas microstrip chambers

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  18. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  19. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping; Wu, Ying; Lai, Yun

    2016-01-01

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  20. LBA-ECO TG-07 Soil CO2 Flux by Automated Chamber, Para, Brazil: 2001-2003

    Science.gov (United States)

    R.K. Varner; M.M. Keller

    2009-01-01

    Measurements of the soil-atmosphere flux of CO2 were made at the km 67 flux tower site in the Tapajos National Forest, Santarem, Para, Brazil. Eight chambers were set up to measure trace gas exchange between the soil and atmosphere about 5 times a day (during daylight and night) at this undisturbed forest site from April 2001 to April 2003. CO2 soil efflux data are...

  1. Numerical investigation of multichannel laser beam phase locking in turbulent atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, V A; Volkov, M V; Garanin, S G; Starikov, F A [Russian Federal Nuclear Center ' All-Russian Research Institute of Experimental Physics' , Sarov, Nizhnii Novgorod region (Russian Federation)

    2015-12-31

    The efficiency of coherent multichannel beam combining under focusing through a turbulent medium on a target in the cases of phase conjugation and target irradiation in the feedback loop is investigated numerically in various approximations. The conditions of efficient focusing of multichannel radiation on the target are found. It is shown that the coherent beam combining with target irradiation in the feedback loop, which does not require a reference beam and wavefront measurements, is as good as the phase conjugation approach in the efficiency of focusing. It is found that the main effect of focusing is provided by properly chosen phase shifts in the channels, whereas taking into account local wavefront tip tilts weakly affects the result. (control of laser radiation parameters)

  2. The Role of Multichannel Marketing in Customer Retention and Loyalty: Study in Emerald Bank Customer in Indonesia

    Directory of Open Access Journals (Sweden)

    Ambarwati Ambarwati

    2015-09-01

    Full Text Available Attention on the relationship between customer retention, customer loyalty, and customer satisfaction that serves as "seed" of customer loyalty highlight the important factors for multichannel management. With the growing trends of people in investing their money in bank for securities need to be responded by the marketing department to create better marketing strategies. The purpose of this study is to examine and explain the effect of a multichannel bank on emerald customers retention   in one of the largest SOE bank in Indonesia, in the city of Surabaya, BNI (Bank Negara Indonesia toward customer  satisfaction, loyalty and customer  retention. This study develops the theory  of  mix marketing by using multichannel  as one of the elements that can increase customer retention   using satisfaction mediation and customer loyalty. Mechanical determination of sample units in this study is a  purposive sampling, of 89 respondents. Generalized Structured Component Analysis (GSCA was applied to test the hypotheses. The results of this study indicate that direct multichannel not  significantly effect the customer retention. Customer satisfaction can not be a perfect mediation  and the customer loyalty can be a perfect mediation in the relationship between multichannel and customer retention. This study contributes to the banking industry in applying the concept of the mix marketing.

  3. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  4. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  5. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    In this paper, a method for multi-channel pitch estimation is proposed. The method is a maximum likelihood estimator and is based on a parametric model where the signals in the various channels share the same fundamental frequency but can have different amplitudes, phases, and noise characteristics....... This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  6. Simple multifunction discriminator for multichannel triggers

    International Nuclear Information System (INIS)

    Maier, M.R.

    1982-10-01

    A simple version of a multifunction timing discriminator using only two integrated circuits is presented. It can be configured as a leading edge, a constant fraction, a zero cross or a dual threshold timing discriminator. Since so few parts are used, it is well suited for building multichannel timing discriminators. Two versions of this circuit are described: a quadruple multifunction discriminator and an octal constant fraction trigger. The different compromises made in these units are discussed. Results for walk and jitter obtained with these are presented and possible improvements are disussed

  7. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  8. Feasibility study of applying a multi-channel analysis model to on-line core monitoring system

    International Nuclear Information System (INIS)

    In, W. K.; Yoo, Y. J.; Hwang, D. H.; Jun, T. H.

    1998-01-01

    A feasibility study was performed to evaluate the effect of implementing a multi-channel analysis model in on-line core monitoring system. A simplified thermal-hydraulic model has been used in the on-line core monitoring system of digital PWR. The design procedure, core thermal margin and computation time were investigated in case of replacing the simplified model with the multi-channel analysis model. For the given ranges of limiting conditions for operation in Yonggwang Unit 3 Cycle 1, the minimum DNBR of the simplified thermal-hydraulic code CETOP-D was compared to that of the multi-channel analysis code MATRA. A CETOP-D tuning is additionally required to ensure the accurate and conservative DNBR calculation but the MATRA tuning is not necessary. MATRA appeared to increase the DNBR overpower margin from 2.5% to 6% over the CETOP-D margin. MATRA took approximately 1 second to compute DNBR on the HP9000 workstation system, which is longer than the DNBR computation time of CETOP-D. It is, however, fast enough to perform the on-line monitoring of DNBR. It can be therefore concluded that the application of the multi-channel analysis model MATRA in the on-line core monitoring system is feasible

  9. Field microcomputerized multichannel γ ray spectrometer based on notebook computer

    International Nuclear Information System (INIS)

    Jia Wenyi; Wei Biao; Zhou Rongsheng; Li Guodong; Tang Hong

    1996-01-01

    Currently, field γ ray spectrometry can not rapidly measure γ ray full spectrum, so a field microcomputerized multichannel γ ray spectrometer based on notebook computer is described, and the γ ray full spectrum can be rapidly measured in the field

  10. Lab-on-a-Disc Platform for Automated Chemical Cell Lysis

    Directory of Open Access Journals (Sweden)

    Moo-Jung Seo

    2018-02-01

    Full Text Available Chemical cell lysis is an interesting topic in the research to Lab-on-a-Disc (LOD platforms on account of its perfect compatibility with the centrifugal spin column format. However, standard procedures followed in chemical cell lysis require sophisticated non-contact temperature control as well as the use of pressure resistant valves. These requirements pose a significant challenge thereby making the automation of chemical cell lysis on an LOD extremely difficult to achieve. In this study, an LOD capable of performing fully automated chemical cell lysis is proposed, where a combination of chemical and thermal methods has been used. It comprises a sample inlet, phase change material sheet (PCMS-based temperature sensor, heating chamber, and pressure resistant valves. The PCMS melts and solidifies at a certain temperature and thus is capable of indicating whether the heating chamber has reached a specific temperature. Compared to conventional cell lysis systems, the proposed system offers advantages of reduced manual labor and a compact structure that can be readily integrated onto an LOD. Experiments using Salmonella typhimurium strains were conducted to confirm the performance of the proposed cell lysis system. The experimental results demonstrate that the proposed system has great potential in realizing chemical cell lysis on an LOD whilst achieving higher throughput in terms of purity and yield of DNA thereby providing a good alternative to conventional cell lysis systems.

  11. Lab-on-a-Disc Platform for Automated Chemical Cell Lysis.

    Science.gov (United States)

    Seo, Moo-Jung; Yoo, Jae-Chern

    2018-02-26

    Chemical cell lysis is an interesting topic in the research to Lab-on-a-Disc (LOD) platforms on account of its perfect compatibility with the centrifugal spin column format. However, standard procedures followed in chemical cell lysis require sophisticated non-contact temperature control as well as the use of pressure resistant valves. These requirements pose a significant challenge thereby making the automation of chemical cell lysis on an LOD extremely difficult to achieve. In this study, an LOD capable of performing fully automated chemical cell lysis is proposed, where a combination of chemical and thermal methods has been used. It comprises a sample inlet, phase change material sheet (PCMS)-based temperature sensor, heating chamber, and pressure resistant valves. The PCMS melts and solidifies at a certain temperature and thus is capable of indicating whether the heating chamber has reached a specific temperature. Compared to conventional cell lysis systems, the proposed system offers advantages of reduced manual labor and a compact structure that can be readily integrated onto an LOD. Experiments using Salmonella typhimurium strains were conducted to confirm the performance of the proposed cell lysis system. The experimental results demonstrate that the proposed system has great potential in realizing chemical cell lysis on an LOD whilst achieving higher throughput in terms of purity and yield of DNA thereby providing a good alternative to conventional cell lysis systems.

  12. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630

  13. Salt Intrusion, Tides and Mixing in Multi-channel Estuaries

    NARCIS (Netherlands)

    Nguyen, A.D.

    2008-01-01

    Multi-channel estuaries, such as the Mekong Delta in Vietnam and the Scheldt in the Netherlands, have characteristics of both the river and the sea, forming a unique environment influenced by tidal movements of the sea and freshwater flow of the river. This study addresses a number of knowledge gaps

  14. Software Configurable Multichannel Transceiver

    Science.gov (United States)

    Freudinger, Lawrence C.; Cornelius, Harold; Hickling, Ron; Brooks, Walter

    2009-01-01

    Emerging test instrumentation and test scenarios increasingly require network communication to manage complexity. Adapting wireless communication infrastructure to accommodate challenging testing needs can benefit from reconfigurable radio technology. A fundamental requirement for a software-definable radio system is independence from carrier frequencies, one of the radio components that to date has seen only limited progress toward programmability. This paper overviews an ongoing project to validate the viability of a promising chipset that performs conversion of radio frequency (RF) signals directly into digital data for the wireless receiver and, for the transmitter, converts digital data into RF signals. The Software Configurable Multichannel Transceiver (SCMT) enables four transmitters and four receivers in a single unit the size of a commodity disk drive, programmable for any frequency band between 1 MHz and 6 GHz.

  15. Establishment of automated culture system for murine induced pluripotent stem cells

    Directory of Open Access Journals (Sweden)

    Koike Hiroyuki

    2012-11-01

    Full Text Available Abstract Background Induced pluripotent stem (iPS cells can differentiate into any cell type, which makes them an attractive resource in fields such as regenerative medicine, drug screening, or in vitro toxicology. The most important prerequisite for these industrial applications is stable supply and uniform quality of iPS cells. Variation in quality largely results from differences in handling skills between operators in laboratories. To minimize these differences, establishment of an automated iPS cell culture system is necessary. Results We developed a standardized mouse iPS cell maintenance culture, using an automated cell culture system housed in a CO2 incubator commonly used in many laboratories. The iPS cells propagated in a chamber uniquely designed for automated culture and showed specific colony morphology, as for manual culture. A cell detachment device in the system passaged iPS cells automatically by dispersing colonies to single cells. In addition, iPS cells were passaged without any change in colony morphology or expression of undifferentiated stem cell markers during the 4 weeks of automated culture. Conclusions Our results show that use of this compact, automated cell culture system facilitates stable iPS cell culture without obvious effects on iPS cell pluripotency or colony-forming ability. The feasibility of iPS cell culture automation may greatly facilitate the use of this versatile cell source for a variety of biomedical applications.

  16. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  17. Experimental researches and comparison on aerodynamic parameters and cleaning efficiency of multi-level multi-channel cyclone

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2015-10-01

    Full Text Available Multi-level multi-channel cyclone – the lately designed air cleaning device that can remove ultra-fine 20 μm particulatematter (PM from dusted air and reach over 95% of the overall cleaning efficiency. Multi-channel cyclone technology is based on centrifugal forces and has the resulting additional filtering process operation. Multi-level structure of cyclone allows to achieve higher air flow cleaning capacity at the same dimensions of the device, thus saving installation space required for the job, production and operating costs. Studies have examined the air flow parameters change in one–, two– and three–levels multichannel cyclone. These constructions differ according to the productivity of cleaned air under the constant peripheral and transitional (50/50 case air flow relations. Accordance with the results of air flow dynamics – velocity distribution of multi-channel cyclone, aerodynamic resistance and efficiency can be judged on the flow turbulence, the flow channel cross-section and select the most appropriate application. Cleaning efficiency studies were carried out using fine granite and wood ashes PM. The maximum cleaning efficiency was 93.3%, at an average of 4.5 g/m3, the aerodynamic resistance was equal to 1525 Pa.

  18. A Novel Spectrally Efficient Asynchronous Multi-Channel MAC Using a Half-Duplex Transceiver for Wireless Networks

    Directory of Open Access Journals (Sweden)

    Abdullah Devendiran

    2018-01-01

    Full Text Available Multi-channel medium access control (MAC protocols maximize network performance by enabling concurrent wireless transmissions over non-interfering channels. Despite physical layer advancements, the underlying IEEE 802.11 MAC standard cannot fully exploit features and support high-performance applications. In this work, we propose the novel spectrally efficient asynchronous multi-channel MAC (SA-MMAC protocol for wireless networks using a single half-duplex transceiver. A full-duplex mode of operation on data channels reduces the signaling overhead and boosts the spectrum efficiency. A revamped contention mechanism of IEEE 802.11 addresses the multi-channel hidden terminal problem, and a jamming signal from the receiver addresses the collisions in control signals. Furthermore, the control channel is used for data transmissions to increase the bandwidth utilization but under a restricted half-duplex mode to avoid causing a bottleneck situation. The simulator is tested for correctness. The results suggest that the protocol can work well on 3, 4, or 12 concurrent channels with high node density, providing about 12.5 times more throughput than IEEE 802.11 and 18% to 95% more throughput than its multi-channel variants under saturated traffic conditions.

  19. New-fashioned Multi-channel Analyzer Based on Bipartition Method

    International Nuclear Information System (INIS)

    Liu Mingjian; Zhang Yan; Yan Xuekun; Chen Ying

    2009-01-01

    A new-fashioned digital-analog converter (DAC) which can find the pulse-signal amplitude through dichotomy is devised. With this new DAC method, a 256-channel multi-channel pulse amplitude analyzer (MCA) is designed successfully, and its hardware and software are introduced in detail. This provides a new method for designing MCA. (authors)

  20. Solution of complex measuring problems for automation of a scientific experiment and technological processes; Reshenie slozhnykh izmeritel`nykh problem pri avtomatizatsii nauchnogo ehksperimenta i tekhnologicheskikh protsessov

    Energy Technology Data Exchange (ETDEWEB)

    Gribov, A A; Zhukov, V A; Sdobnov, S I; Yakovlev, G V [Rossijskij Nauchnyj Tsentr Kurchatovskij Inst., Moskva (Russian Federation)

    1996-12-31

    Paper discusses problems linked with automation of reactor measurements. Paper describes automated system to carry out neutron-physical experiments linked with measuring of slowly varying current of ionization chambers. The system is based on the trunk-module principle with application of a specialized 16-discharge trunk. Total information capacity for one current channel constitutes 5 bytes. 4 refs.; 1 fig.

  1. Multichannel spin polarimeter for energy- and angle-dispersive photoemission measurements; Vielkanal-Spinpolarimeter fuer energie- und winkeldispersive Photoemissionsmessungen

    Energy Technology Data Exchange (ETDEWEB)

    Kolbe, Michaela

    2011-09-09

    Spin polarization measurements of free electrons remain challenging since their first realization by Mott. The relevant quantity of a spin polarimeter is its figure of merit, FoM=S{sup 2}I/I{sub 0}, with the asymmetry function S and the ratio between scattered and primary intensity I/I{sub 0}. State-of-the-art devices are based on single-channel scattering (spin-orbit or exchange interaction) which is characterized by FoM {approx_equal}10{sup -4}. On the other hand, modern hemispherical analyzers feature an efficient multichannel detection of spin-integral intensity with more than 10{sup 4} data points simultaneously. In comparison between spin-resolved and spin-integral electron spectroscopy we are thus faced with a difference in counting efficiency by 8 orders of magnitude. The present work concentrates on the development and investigation of a novel technique for increasing the efficiency in spin-resolved electron spectroscopy by multichannel detection. The spin detector was integrated in a {mu}-metal shielded UHV-chamber and mounted behind a conventional hemispherical analyzer. The electrostatic lens system's geometry was determined by electron-optical simulations. The basic concept is the k {sub parallel} -conserving elastic scattering of the (0,0)-beam on a W(100) scattering crystal under 45 impact angle. It could be demonstrated that app. 960 data points (15 energy and 64 angular points) could be displayed simultaneously on a delayline detector in an energy interval of {approx_equal}3 eV. This leads to a two-dimensional figure of merit of FoM{sub 2D}=1.7. Compared to conventional spin detectors, the new type is thus characterized by a gain in efficiency of 4 orders of magnitude. The operational reliability of the new spin polarimeter could be proven by measurements with a Fe/MgO(100) and O p(1 x 1)/Fe(100)-sample, where results from the literature were reproduced with strongly decreased measuring time. Due to the high intensity it becomes possible, to

  2. Striatal lesions produce distinctive impairments in reaction time performance in two different operant chambers.

    Science.gov (United States)

    Brasted, P J; Döbrössy, M D; Robbins, T W; Dunnett, S B

    1998-08-01

    The dorsal striatum plays a crucial role in mediating voluntary movement. Excitotoxic striatal lesions in rats have previously been shown to impair the initiation but not the execution of movement in a choice reaction time task in an automated lateralised nose-poke apparatus (the "nine-hole box"). Conversely, when a conceptually similar reaction time task has been applied in a conventional operant chamber (or "Skinner box"), striatal lesions have been seen to impair the execution rather than the initiation of the lateralised movement. The present study was undertaken to compare directly these two results by training the same group of rats to perform a choice reaction time task in the two chambers and then comparing the effects of a unilateral excitotoxic striatal lesion in both chambers in parallel. Particular attention was paid to adopting similar parameters and contingencies in the control of the task in the two test chambers. After striatal lesions, the rats showed predominantly contralateral impairments in both tasks. However, they showed a deficit in reaction time in the nine-hole box but an apparent deficit in response execution in the Skinner box. This finding confirms the previous studies and indicates that differences in outcome are not simply attributable to procedural differences in the lesions, training conditions or tasks parameters. Rather, the pattern of reaction time deficit after striatal lesions depends critically on the apparatus used and the precise response requirements for each task.

  3. Integrated multi-channel vehicle-vehicle and vehicle-roadside communications for ITS

    Science.gov (United States)

    2008-12-01

    This research describes a medium access control (MAC) protocol to Enable multi-channel operation for dedicated short-range communication (DSRC). In particular, we focus on the challenge of supporting potentially high-bandwidth commercial or infotainm...

  4. Skyrmion-based multi-channel racetrack

    Science.gov (United States)

    Song, Chengkun; Jin, Chendong; Wang, Jinshuai; Xia, Haiyan; Wang, Jianbo; Liu, Qingfang

    2017-11-01

    Magnetic skyrmions are promising for the application of racetrack memories, logic gates, and other nano-devices, owing to their topologically protected stability, small size, and low driving current. In this work, we propose a skyrmion-based multi-channel racetrack memory where the skyrmion moves in the selected channel by applying voltage-controlled magnetic anisotropy gates. It is demonstrated numerically that a current-dependent skyrmion Hall effect can be restrained by the additional potential of the voltage-controlled region, and the skyrmion velocity and moving channel in the racetrack can be operated by tuning the voltage-controlled magnetic anisotropy, gate position, and current density. Our results offer a potential application of racetrack memory based on skyrmions.

  5. Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays

    International Nuclear Information System (INIS)

    Kong Jie; Su Hong; Chen Zhiqiang; Dong Chengfu; Qian Yi; Gao Shanshan; Zhou Chaoyang; Lu Wan; Ye Ruiping; Ma Junbing

    2010-01-01

    A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable GI controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz.

  6. Very low cost multichannel analyzer with some additional features

    Energy Technology Data Exchange (ETDEWEB)

    Tudyka, Konrad, E-mail: konrad.tudyka@polsl.pl [Centre of Excellence-Gliwice Absolute Dating Methods Centre, Institute of Physics, Silesian University of Technology (Poland); Bluszcz, Andrzej [Centre of Excellence-Gliwice Absolute Dating Methods Centre, Institute of Physics, Silesian University of Technology (Poland)

    2011-12-11

    In this paper we present a multichannel analyzer (MCA) based on a digital signal controller (DSC). The multichannel analyzer is characterized by a very low cost and an additional feature of recording time intervals between pulses. The total cost of electronic parts used in construction of the MCA is around 50 USD. The electronic circuit is based on dsPIC30F2020 DSC unit from Microchip. The device has a 10-bit analogue-to-digital converter (ADC) which can sample and convert 2 samples per {mu}s. The DSC samples the input voltage continuously and detects incoming pulses. The data belonging to a detected pulse and its time stamp are sent to a PC on-line. The analysis of data stored on the PC is performed off-line with the help of a genetic algorithm (GA) used to fit the pulse shape function. This allows determination of amplitude of each individual pulse. The effective resolution varies with the pulse length and is typically 1000 channels for pulses approximately 4{mu}s long.

  7. Development of automated control system for wood drying

    Science.gov (United States)

    Sereda, T. G.; Kostarev, S. N.

    2018-05-01

    The article considers the parameters of convective wood drying which allows changing the characteristics of the air that performs drying at different stages: humidity, temperature, speed and direction of air movement. Despite the prevalence of this type of drying equipment, the main drawbacks of it are: the high temperature and humidity, negatively affecting the working conditions of maintenance personnel when they enter the drying chambers. It makes the automation of wood drying process necessary. The synthesis of a finite state of a machine control of wood drying process is implemented on a programmable logic device Omron.

  8. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  9. A Multichannel Calorimetric Simultaneous Assay Platform Using a Microampere Constant-Current Looped Enthalpy Sensor Array

    Directory of Open Access Journals (Sweden)

    Hsien-Chin Wei

    2017-02-01

    Full Text Available Calorimetric biochemical measurements offer various advantages such as low waste, low cost, low sample consumption, short operating time, and labor-savings. Multichannel calorimeters can enhance the possibility of performing higher-throughput biochemical measurements. An enthalpy sensor (ES array is a key device in multichannel calorimeters. Most ES arrays use Wheatstone bridge amplifiers to condition the sensor signals, but such an approach is only suitable for null detection and low resistance sensors. To overcome these limitations, we have developed a multichannel calorimetric simultaneous assay (MCSA platform. An adjustable microampere constant-current (AMCC source was designed for exciting the ES array using a microampere current loop measurement circuit topology. The MCSA platform comprises a measurement unit, which contains a multichannel calorimeter and an automatic simultaneous injector, and a signal processing unit, which contains multiple ES signal conditioners and a data processor. This study focused on the construction of the MCSA platform; in particular, construction of the measurement circuit and calorimeter array in a single block. The performance of the platform, including current stability, temperature sensitivity and heat sensitivity, was evaluated. The sensor response time and calorimeter constants were given. The capability of the platform to detect relative enzyme activity was also demonstrated. The experimental results show that the proposed MCSA is a flexible and powerful biochemical measurement device with higher throughput than existing alternatives.

  10. Coordinating Multi-Channel Pricing of Seasonal Goods

    OpenAIRE

    Preetam Basu

    2012-01-01

    Advancement in information technology has opened new avenues for traditional retailers to expand their operations. Pricing, which has been a critical issue, is more important than ever before as traditional retailers pursue multi-channel sales. In this paper the author studies the pricing problem of a retailer selling a seasonal product simultaneously in a ‘brick and mortar’ store as well as online. Optimal prices are derived and different product-market conditions are determined under wh...

  11. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  12. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  13. A combination drift chamber/pad chamber for very high readout rates

    International Nuclear Information System (INIS)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W.; Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J.; Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S.; Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N.; Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T.; Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S.; Budagov, J.; Tsyganov, E.; Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N.; Chen, T.Y.; Yao, N.; Clark, K.; Jenkins, M.; Cooper, M.; Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Fortney, L.; Kowald, W.; Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D.; Lau, K.; Mo, G.; Trischuk, J.

    1991-11-01

    Six medium-sized (∼1 x 2 m 2 ) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers

  14. A combination drift chamber/pad chamber for very high readout rates

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. (Wisconsin Univ., Madison, WI (United States)); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. (Pavia Univ. (Italy) Istituto Nazionale di Fisica Nucleare, Rome (Italy)); Arenton, M.; Conetti, S.

    1991-11-01

    Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.

  15. A low power Multi-Channel Analyzer

    International Nuclear Information System (INIS)

    Anderson, G.A.; Brackenbush, L.W.

    1993-06-01

    The instrumentation used in nuclear spectroscopy is generally large, is not portable, and requires a lot of power. Key components of these counting systems are the computer and the Multi-Channel Analyzer (MCA). To assist in performing measurements requiring portable systems, a small, very low power MCA has been developed at Pacific Northwest Laboratory (PNL). This MCA is interfaced with a Hewlett Packard palm top computer for portable applications. The MCA can also be connected to an IBM/PC for data storage and analysis. In addition, a real-time time display mode allows the user to view the spectra as they are collected

  16. A Novel Architecture For Multichannel Analyzer

    International Nuclear Information System (INIS)

    Marcus, E.; Elhanani, I.; Nir, J.; Ellenbogen, M.; Kadmon, Y.; Tirosh, D.

    1999-01-01

    A novel digital approach to real-time, high-throughput, low-cost Multichannel Analyzer (MCA) for radiation spectroscopy is being presented. The MCA input is a shaped nuclear pulse sampled at a high rate, using an Analog-to-Digital Converter (ADC) chip. The digital samples are analyzed by a state-of-the-art Field Programmable Gate Away (FPGA). A customized algorithm is utilized to estimate the peak of the pulse, to reject pile-up and to eliminate processing dead time. The valid pulses estimated peaks are transferred to a micro controller system that creates the histogram and controls the Human Machine Interface (HMI)

  17. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  18. Multichannel analyzer for the neutron time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Vojter, A.P.; Slyisenko, V.Yi.; Doronyin, M.Yi.; Maznij, Yi.O.; Vasil'kevich, O.A.; Golyik, V.V.; Koval'ov, O.M.; Kopachov, V.Yi.; Savchuk, V.G.

    2010-01-01

    New multichannel time-of-flight spectrometer for the measurement of the energy and angular distributions of neutrons from the WWWR-M reactor is considered. This spectrometer has been developed for the replacement of the previous one to increase the number of channels and measurement precision, reduce the time of channel tuning and provide the automatic monitoring during the experiment.

  19. A dialog program for the evaluation of multichannel spectra

    International Nuclear Information System (INIS)

    Dietze, G.

    1978-06-01

    The computer code SPEKT is described for the analysis and manipulation of multichannel spectra in neutron dosimetry. It is a dialog system with a simple command string. The code has mainly been written in FORTRAN. Because of the modular structure of the program a user can add new routines in a simple way. (orig./HP) [de

  20. Refurbishment and Automation of the Thermal/Vacuum Facilities at the Goddard Space Flight Center

    Science.gov (United States)

    Donohue, John T.; Johnson, Chris; Ogden, Rick; Sushon, Janet

    1998-01-01

    The thermal/vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the 11 facilities, currently 10 of the systems are scheduled for refurbishment and/or replacement as part of a 5-year implementation. Expected return on investment includes the reduction in test schedules, improvements in the safety of facility operations, reduction in the complexity of a test and the reduction in personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering and for the automation of thermal/vacuum facilities and thermal/vacuum tests. Automation of the thermal/vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs) and the use of Supervisory Control and Data Acquisition (SCADA) systems. These components allow the computer control and automation of mechanical components such as valves and pumps. In some cases, the chamber and chamber shroud require complete replacement while others require only mechanical component retrofit or replacement. The project of refurbishment and automation began in 1996 and has resulted in the computer control of one Facility (Facility #225) and the integration of electronically controlled devices and PLCs within several other facilities. Facility 225 has been successfully controlled by PLC and SCADA for over one year. Insignificant anomalies have occurred and were resolved with minimal impact to testing and operations. The amount of work remaining to be performed will occur over the next four to five years. Fiscal year 1998 includes the complete refurbishment of one facility, computer control of the thermal systems in two facilities, implementation of SCADA and PLC systems to support multiple facilities and the implementation of a Database server to allow efficient test management and data analysis.

  1. Light coupling and distribution for Si3N4/SiO2 integrated multichannel single-mode sensing system

    Science.gov (United States)

    Kaźmierczak, Andrzej; Dortu, Fabian; Schrevens, Olivier; Giannone, Domenico; Bouville, David; Cassan, Eric; Gylfason, Kristinn B.; Sohlström, Hans; Sanchez, Benito; Griol, Amadeu; Hill, Daniel

    2009-01-01

    We present an efficient and highly alignment-tolerant light coupling and distribution system for a multichannel Si3N4/SiO2 single-mode photonics sensing chip. The design of the input and output couplers and the distribution splitters is discussed. Examples of multichannel data obtained with the system are given.

  2. Ultrasmall and customizable multichannel electrodes for extracellular recordings.

    Science.gov (United States)

    Piironen, Arto; Weckström, Matti; Vähäsöyrinki, Mikko

    2011-03-01

    Increasing demand exists for smaller multichannel electrodes that enable simultaneous recordings of many neurons in a noninvasive manner. We report a novel method for manufacturing ultrasmall carbon fiber electrodes with up to seven closely spaced recording sites. The electrodes were designed to minimize damage to neuronal circuitry and to be fully customizable in three dimensions so that their dimensions can be optimally matched to those of the targeted neuron population.

  3. Regret of Multi-Channel Bandit Game in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Ma Jun

    2016-01-01

    Full Text Available The problem of how to evaluate the rate of convergence to Nash equilibrium solutions in the process of channel selection under incomplete information is studied. In this paper, the definition of regret is used to reflect the convergence rates of online algorithms. The process of selecting an idle channel for each secondary user is modeled as a multi-channel bandit game. The definition of the maximal averaged regret is given. Two existing online learning algorithms are used to obtain the Nash equilibrium for each SU. The maximal averaged regrets are used to evaluate the performances of online algorithms. When there is a pure strategy Nash equilibrium in the multi-channel bandit game, the maximal averaged regrets are finite. A cooperation mechanism is also needed in the process of calculating the maximal averaged regrets. Simulation results show the maximal averaged regrets are finite and the online algorithm with greater convergence rate has less maximal averaged regrets.

  4. Car-borne multichannel gamma-ray spectrometric system model CZD-6

    International Nuclear Information System (INIS)

    Lu Shili; Zhai Yugui; Ma Yanfang; Jiao Cangwen; Zhang Biao

    1998-01-01

    The car-borne multichannel gamma-ray spectrometric system Mode CZD-6 is composed of a HDY-256 of portable multichannel gamma-ray spectrometer developed by the Beijing Research Institute of Uranium Geology and a large volume scintillation detector. the position for each measurement point is determined by the GPS instrument. Its latitude and longitude, as well as measured 256 channels of γ-spectrometric data are collected by a notebook computer, which can show the 256 channels of spectra for each point during measuring processes. The complete system can be loaded in a field car. This system has been used to environmental radioactive monitoring after calibration by airborne radiometric models in Shijiazhuang, Hebei province. A lot of data confirm that the system works stably and reliably, and is a fast and advanced approach for environmental γ-spectrometric monitoring. It can be used not only to determination of contents of natural radioactive elements in environments, but also to monitoring nuclear pollution and emergency treatment in nuclear accidents significantly

  5. Research on development of multi-channel analyzer used for monitoring and warning radiation equipment

    International Nuclear Information System (INIS)

    Nguyen Van Sy; Dang Quang Thieu; Nguyen Thi Bao My

    2015-01-01

    The subject assigned to this paper presents research on development of multi-channel analyzer used for monitoring and warning environmental radiation equipment under the project KC.05.16/11-15 Research on manufacturing equipment monitoring and warning radiation. In this thematic we have two subjects that need to be resolved such as: i) Designing spectroscopy amplifier block (AMP) duty pulse signals obtained about few hundred millivolts output from scintillation detector preamplifier, amplified as a few volts and the standard Gaussian pulses shaped to connect to the analog-to-digital converter. The spectroscopy amplifier block can change the gain by digital control to respond to the problem of automatic spectrum stability for multi-channel analyzer systems. ii) Designing analog-to-digital converter block (ADC) in accordance with the actual conditions, such as high stability, fast conversion time, high throughput, and it consumes low energy. Selecting suitable microprocessor for fast connection ability, to operate reliably paired with the analog-to-digital converter into a multi-channel analyzer (MCA) serving analysis. (author)

  6. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  7. Whole System Carbon Exchange of Small Stands of Pinus Ponderosa Growing at Different CO(sub 2) concentrations in open top chambers; FINAL

    International Nuclear Information System (INIS)

    Ball, J. Timothy; Ross, Peter D.; Picone, John B.; Eichelmann, Hillar Y.; Ross, Gregory N.

    1996-01-01

    Functional understanding of the carbon cycle from the molecular to the global level is a high scientific priority requiring explanation of the relationship between fluxes at different spatial and temporal scales. We describe methods used to convert an open top chamber into both closed and open flow gas exchange systems utilized to measure such fluxes. The systems described consist of temporary modifications to an open top chamber, and are put in place for several days on one or several open top chambers. In the closed system approach, a chamber is quickly sealed for a short, predetermined time interval, the change in gas concentrations is measured, then the chamber is unsealed and ventilated. In the open flow system approach, airflow into the open top chamber is measured by trace gas injection, and the air stream concentration of CO(sub 2) and water vapor is measured before and after injection into the chamber. The closed chamber approach can resolve smaller fluxes, but causes transient increases in chamber air temperature, and has a high labor requirement. The open flow approach reduces the deviation of measuring conditions from ambient, may be semi-automated (requiring less labor), allows a more frequent sampling interval, but cannot resolve low fluxes well. Data demonstrating the capabilities of these systems show that, in open canopies of ponderosa pine, scaling fluxes from leaves to whole canopies is well approximated from summation of leaf P(sub s) rates. Flux measurements obtained from these systems can be a valuable contribution to our understanding whole system material fluxes, and challenge our understanding of ecosystem carbon budgets

  8. Novel Methods for Measuring Depth of Anesthesia by Quantifying Dominant Information Flow in Multichannel EEGs

    Directory of Open Access Journals (Sweden)

    Kab-Mun Cha

    2017-01-01

    Full Text Available In this paper, we propose novel methods for measuring depth of anesthesia (DOA by quantifying dominant information flow in multichannel EEGs. Conventional methods mainly use few EEG channels independently and most of multichannel EEG based studies are limited to specific regions of the brain. Therefore the function of the cerebral cortex over wide brain regions is hardly reflected in DOA measurement. Here, DOA is measured by the quantification of dominant information flow obtained from principle bipartition. Three bipartitioning methods are used to detect the dominant information flow in entire EEG channels and the dominant information flow is quantified by calculating information entropy. High correlation between the proposed measures and the plasma concentration of propofol is confirmed from the experimental results of clinical data in 39 subjects. To illustrate the performance of the proposed methods more easily we present the results for multichannel EEG on a two-dimensional (2D brain map.

  9. Multichannel fiber laser Doppler vibrometer studies of low momentum and hypervelocity impacts

    Science.gov (United States)

    Posada-Roman, Julio E.; Jackson, David A.; Cole, Mike J.; Garcia-Souto, Jose A.

    2017-12-01

    A multichannel optical fiber laser Doppler vibrometer was demonstrated with the capability of making simultaneous non-contact measurements of impacts at 3 different locations. Two sets of measurements were performed, firstly using small ball bearings (1 mm-5.5 mm) falling under gravity and secondly using small projectiles (1 mm) fired from an extremely high velocity light gas gun (LGG) with speeds in the range 1 km/s-8 km/s. Determination of impact damage is important for industries such as aerospace, military and rail, where the effect of an impact on the structure can result in a major structural damage. To our knowledge the research reported here demonstrates the first trials of a multichannel fiber laser Doppler vibrometer being used to detect hypervelocity impacts.

  10. Multichannel deconvolution and source detection using sparse representations: application to Fermi project

    International Nuclear Information System (INIS)

    Schmitt, Jeremy

    2011-01-01

    This thesis presents new methods for spherical Poisson data analysis for the Fermi mission. Fermi main scientific objectives, the study of diffuse galactic background et the building of the source catalog, are complicated by the weakness of photon flux and the point spread function of the instrument. This thesis proposes a new multi-scale representation for Poisson data on the sphere, the Multi-Scale Variance Stabilizing Transform on the Sphere (MS-VSTS), consisting in the combination of a spherical multi-scale transform (wavelets, curvelets) with a variance stabilizing transform (VST). This method is applied to mono- and multichannel Poisson noise removal, missing data interpolation, background extraction and multichannel deconvolution. Finally, this thesis deals with the problem of component separation using sparse representations (template fitting). (author) [fr

  11. Baking Powder Actuated Centrifugo-Pneumatic Valving for Automation of Multi-Step Bioassays

    Directory of Open Access Journals (Sweden)

    David J. Kinahan

    2016-10-01

    Full Text Available We report a new flow control method for centrifugal microfluidic systems; CO2 is released from on-board stored baking powder upon contact with an ancillary liquid. The elevated pressure generated drives the sample into a dead-end pneumatic chamber sealed by a dissolvable film (DF. This liquid incursion wets and dissolves the DF, thus opening the valve. The activation pressure of the DF valve can be tuned by the geometry of the channel upstream of the DF membrane. Through pneumatic coupling with properly dimensioned disc architecture, we established serial cascading of valves, even at a constant spin rate. Similarly, we demonstrate sequential actuation of valves by dividing the disc into a number of distinct pneumatic chambers (separated by DF membranes. Opening these DFs, typically through arrival of a liquid to that location on a disc, permits pressurization of these chambers. This barrier-based scheme provides robust and strictly ordered valve actuation, which is demonstrated by the automation of a multi-step/multi-reagent DNA-based hybridization assay.

  12. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  13. A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Networks

    Science.gov (United States)

    2001-01-01

    00-00-2001 to 00-00-2001 4. TITLE AND SUBTITLE A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Netowrks 5a. CONTRACT NUMBER...images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE

  14. An optimal multi-channel memory controller for real-time systems

    NARCIS (Netherlands)

    Gomony, M.D.; Akesson, K.B.; Goossens, K.G.W.

    2013-01-01

    Optimal utilization of a multi-channel memory, such as Wide IO DRAM, as shared memory in multi-processor platforms depends on the mapping of memory clients to the memory channels, the granularity at which the memory requests are interleaved in each channel, and the bandwidth and memory capacity

  15. Dual-chamber inflatable oil boom

    International Nuclear Information System (INIS)

    Blair, R.M.; Tedeschi, E.T.

    1993-01-01

    An elongated floating material containment boom section is described having a normally vertical ballasted skirt depending from flotation means, and convertible from a flattened collapsed condition to a deployable condition wherein buoyancy chamber means extending along the upper edge of said skirt are inflated to expanded buoyant configuration, including: a gas-impervious sleeve extending along the upper edge of said normally vertical skirt forming a first outer collapsible and inflatable flotation chamber, a first inflation valve connecting the interior of said sleeve with the ambient atmosphere, through which gas under pressure may be introduced into said sleeve to inflate said first buoyant outer flotation chamber, elongated gas-impervious tube means positioned inside said outer flotation chamber and forming second collapsible and inflatable internal flotation bladder chamber means, second inflation valve means connecting the interior of said bladder means through said outer flotation chamber to the ambient atmosphere through which gas under pressure may be introduced into said bladder means to inflate it forming said second flotation chamber means inside said outer flotation chamber

  16. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  17. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  18. The designing principle and implementation of multi-channel intelligence isotope thickness gauge based on multifunction card PCI-1710

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Guo Maotian; He Jintian

    2006-01-01

    The designing principle, the constitution of system and the implementation of multi-channel intelligence isotope thickness gauge are introduced in the paper in detail, which are based on multifunction card PCI-1710. The paper also discusses the primaryprinciple of isotope thickness gauge, correct factor in measurement and complication of calibration. In the following, the whole frame of multi-channel intelligence isotope thickness gauge is given. The functions, the characteristics and the usage of multifunction card PCI-1710 are described. Furthermore, the developing process and the function modules of software are presented. Finally, the real prototype of multi-channel intelligence isotope thickness gauge is introduced, using 241 Am as a radioactive element. (authors)

  19. Multichannel Seismic Reflection - SCAR- Prydz Bay 1980 SDLS CD-ROM vol 8

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1980 in the Prydz Bay region, by Australian Geological Survey Organization. The...

  20. A novel portable multi-channel analyzer based on high-speed microcontroller

    International Nuclear Information System (INIS)

    Lou Xinghua; Yi Hongchang; Wang Yuemin

    2005-01-01

    This paper introduces a novel portable multi-channel analyzer (MCA) based on high-speed microcontroller. The hardware implementation and the software scenario of the MCA are discussed. The MCA has features of high speed, small size and better performances. (authors)

  1. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  2. A multichannel smartphone optical biosensor for high-throughput point-of-care diagnostics.

    Science.gov (United States)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2017-01-15

    Current reported smartphone spectrometers are only used to monitor or measure one sample at a time. For the first time, we demonstrate a multichannel smartphone spectrometer (MSS) as an optical biosensor that can simultaneously optical sense multiple samples. In this work, we developed a novel method to achieve the multichannel optical spectral sensing with nanometer resolution on a smartphone. A 3D printed cradle held the smartphone integrated with optical components. This optical sensor performed accurate and reliable spectral measurements by optical intensity changes at specific wavelength or optical spectral shifts. A custom smartphone multi-view App was developed to control the optical sensing parameters and to align each sample to the corresponding channel. The captured images were converted to the transmission spectra in the visible wavelength range from 400nm to 700nm with the high resolution of 0.2521nm per pixel. We validated the performance of this MSS via measuring the concentrations of protein and immunoassaying a type of human cancer biomarker. Compared to the standard laboratory instrument, the results sufficiently showed that this MSS can achieve the comparative analysis detection limits, accuracy and sensitivity. We envision that this multichannel smartphone optical biosensor will be useful in high-throughput point-of-care diagnostics with its minimizing size, light weight, low cost and data transmission function. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  4. A wet effluent denuder/mist-chamber coupled to ion chromatography for the continuous measurement of atmospheric HONO, HNO{sub 3}, NO{sub 3}{sup -} and SO{sub 4}{sup 2-}.

    Energy Technology Data Exchange (ETDEWEB)

    Zellweger, C.; Baltensperger, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Hofer, P. [EMPA, Duebendorf (Switzerland)

    1997-09-01

    A denuder/mist chamber system has been developed for the continuous automated measurement of low level concentrations of HONO, HNO{sub 3} as well as of NO{sub 3}{sup -} and SO{sub 4}{sup 2-}. (author) 2 figs., 1 ref.

  5. Multi-channel fiber optic dew and humidity sensor

    Science.gov (United States)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  6. Multichannel far-infrared phase imaging for fusion plasmas

    International Nuclear Information System (INIS)

    Young, P.E.; Neikirk, D.P.; Tong, P.P.; Rutledge, D.B.; Luhmann, N.C. Jr.

    1985-01-01

    A 20-channel far-infrared imaging interferometer system has been used to obtain single-shot density profiles in the UCLA Microtor tokamak. This system differs from conventional multichannel interferometers in that the phase distribution produced by the plasma is imaged onto a single, monolithic, integrated microbolometer linear detector array and provides significantly more channels than previous far-infrared interferometers. The system has been demonstrated to provide diffraction-limited phase images of dielectric targets

  7. Multichannel Seismic Reflection Data, SCAR - Wilkes Land 1982, SDLS, CD-ROM 15

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from thirteen lines recorded during 1983 off Wilkes Island, Antarctica, by the U.S. Geological...

  8. A new method for multi-channel Fabry-Perot spectroscopy of light pulses in the nanosecond regime

    International Nuclear Information System (INIS)

    Behn, R.

    1975-01-01

    The demand for powerful multichannel spectrometers raised, e.g., in laser scattering plasma diagnostics, gave rise to the question if it would not be possible to avoid the light losses occuring in the use of multichannel Fabry-Perot spectrometers. These losses can be avoided with the technique presented here. The reflected light is collected and fed back to the interferometer at a different angle. It can thus be recovered for registration in another spectral channel. This method is particularly suitable for the investigation of short light pulses. A spectrum can thus be scanned step by step with full utilization of the transit time of the light pulse. In addition to light recovery, there is another advantage in that only one detector is used for multichannel analysis, thus eliminating calibration problems. In the annex to the report, emission spectres of different dye laser versions are presented and explained. (orig./GG) [de

  9. Plastic flashtube chambers

    International Nuclear Information System (INIS)

    Frisken, W.R.

    1977-01-01

    A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber

  10. MHD flow in multichannel U-bends: Screening experiments and theoretical analysis

    International Nuclear Information System (INIS)

    Reimann, J.; Molokov, S.; Platnieks, I.; Platacis, E.

    1993-02-01

    In electrically coupled multichannel ducts with a U-bend geometry magnetohydrodynamic effects are expected to cause strongly ununiform distributions of flow rates Q i and pressure drops Δp i in the individual channels. A multichannel U-bend geometry is part of the KfK self-cooled Pb-17 Li blanket design (radial-toroidal-radial channels). However, inserts are proposed which isolate electrically the radial channels (not the toroidal ones). To investigate the multichannel effect (MCE), screening experiments were performed at LAS, Riga, with different flow channel geometries and channel numbers between 1 and 5 and using InGaSn as liquid metal. These experiments were carried out with either Δp i ∼const or Q i ∼const. Hartmann Numbers were varied between 0 and ∼1600 (maximum magnetic field strength: 4.1 T) and Interaction Parameters between 0 and 10000. For experiments with electrically conducting walls between the channels, the volume flow rates in the outer channels are significantly larger than those in the inner channels in the experiments with Δp i ∼const. For Q i ∼const., this tendency is reversed, with the highest pressure drop in the middle channel and the lowest in the outer channels. The flow geometry with electrically separated radial channels, similar to the KfK-design result in a fairly even flow rate and pressure drop distribution. The single channels behave approximately like electrically separated channels; no marked MCE occurrs. A theoretical analysis was carried out to describe the MCE for the multichannel U-bend with thin electrically conducting outside walls. This analysis is based on the Core Flow Approximation (CFA), valid for infinitely large Interaction Parameters and Hartmann Numbers. The theory predicts correctly all tendencies observed for the pressure measurements. Moreover, the method is able to describe in detail the flow structure in the toroidal channel. The most essential result is that the flow rate in the layer close to the

  11. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  12. Multichannel approach to studying scalar resonances

    International Nuclear Information System (INIS)

    Krupa, D.; Surovtsev, Yu.S.

    1995-11-01

    The multichannel approach to the investigation of resonances is given in order to determine their quantum chromodynamical nature. The formula for the analytic continuation of the N-channel S-matrix to the unphysical sheets of the Riemann surface is given, which is a solution of the N-channel problem in that it enables a prediction of the coupled-process amplitudes on the uniformization plane of the S-matrix. The resonance representations by pairs of complex-conjugate clusters of poles and zeros on the Riemann surface are discussed. The concept of standard clusters as model-independent characteristics of the resonance is developed. 32 refs, 5 figs, 4 tabs

  13. Multichannel Baseband Processor for Wideband CDMA

    Science.gov (United States)

    Jalloul, Louay M. A.; Lin, Jim

    2005-12-01

    The system architecture of the cellular base station modem engine (CBME) is described. The CBME is a single-chip multichannel transceiver capable of processing and demodulating signals from multiple users simultaneously. It is optimized to process different classes of code-division multiple-access (CDMA) signals. The paper will show that through key functional system partitioning, tightly coupled small digital signal processing cores, and time-sliced reuse architecture, CBME is able to achieve a high degree of algorithmic flexibility while maintaining efficiency. The paper will also highlight the implementation and verification aspects of the CBME chip design. In this paper, wideband CDMA is used as an example to demonstrate the architecture concept.

  14. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  15. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  16. Applications of a Ga-68/Ge-68 generator system to brain imaging using a multiwire proportional chamber positron camera

    International Nuclear Information System (INIS)

    Hattner, R.S.; Lim, C.B.; Swann, S.J.; Kaufman, L.; Chu, D.; Perez-Mendez, V.

    1976-01-01

    A Ge-68/Ga-68 generator system has been applied to brain imaging in conjunction with a novel coincidence detection based positron camera. The camera consists of two opposed large area multiwire proportional chamber (MWPC) detectors interfaced to multichannel lead converter plates. Event localization is effected of delay lines. Ten patients with brain lesions have been studied 1-2 hours after the administration of Ga-68 formulated as DTPA. The images were compared to conventional brain scans, and to x-ray section scans (CAT). The positron studies have shown significant mitigation of confusing superficial activity resulting from craniotomy compared to conventional brain scans. Central necrosis of lesions observed in positron images, but not in the conventional scans has been confirmed in CAT. The economy of MWPC positron cameras combined with the ideal characteristics of the Ge-68/Ga-68 generator promise a cost efficient imaging system for the future

  17. Simulation and Automation of the EEBI Test at ALS

    CERN Document Server

    Nishimura, Hiroshi

    2005-01-01

    The Errant Electron Beam Interlock (EEBI) is a system that protects the vacuum chamber of the Advanced Light Source (ALS) from synchrotron light damage should the orbit, through a superconducting bend magnet (superbend), become distorted. The EEBI system monitors the vertical beam position on two BPMs, one upstream and the other downstream, of the superbend and dumps the stored beam if the orbit exceeds preset limits in either offset or angle. Discussed are the modeling studies carried out to determine how to create a large vertical bump, both for performing the test and implementing the automated test software.

  18. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  19. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2015-11-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOC) can be studied in detail. In PLUS all important enviromental parameters (e.g. temperature, PAR, soil RH etc.) are well-controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leafes of the plants is constructed such that gases are exposed to FEP Teflon film and other Teflon surfaces only to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 LED panels which have an emission strength up to 800 μmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOC) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light and temperature dependent BVOC emissions are studied using six Quercus Ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus Ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental set up and the utility of the newly added plant chamber.

  20. A new plant chamber facility, PLUS, coupled to the atmosphere simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2016-03-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been built and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow-through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees is mixed with synthetic air and transferred to the SAPHIR chamber, where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOCs) can be studied in detail. In PLUS all important environmental parameters (e.g., temperature, photosynthetically active radiation (PAR), soil relative humidity (RH)) are well controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leaves of the plants is constructed such that gases are exposed to only fluorinated ethylene propylene (FEP) Teflon film and other Teflon surfaces to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 light-emitting diode (LED) panels, which have an emission strength up to 800 µmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOCs) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light- and temperature- dependent BVOC emissions are studied using six Quercus ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental setup and the utility of the newly added plant chamber.

  1. Scanning Multichannel Microwave Radiometer (SMMR) Monthly Mean Atmospheric Liquid Water (ALW) By Prabhakara

    Data.gov (United States)

    National Aeronautics and Space Administration — SMMR_ALW_PRABHAKARA data are Special Multichannel Microwave Radiometer (SMMR) Monthly Mean Atmospheric Liquid Water (ALW) data by Prabhakara.The Prabhakara Scanning...

  2. The impact of the multi-channel retail mix on online store choice: Does online experience matter?

    OpenAIRE

    Melis, Kristina; Campo, Katia; Breugelmans, Els; Lamey, Lien

    2015-01-01

    More and more grocery retailers are becoming multi-channel retailers, as they are opening an online alternative next to their traditional offline supermarkets. While the number of multi-channel grocery shoppers is also expanding at a fast growth rate, there are still large differences in online shopping frequency, and as a result, in the levels of experience with buying in the online grocery channel. This study wants to (i) identify the underlying drivers of online store choice and (ii) explo...

  3. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  4. Complete automation of nuclear reactors control

    International Nuclear Information System (INIS)

    Weill, J.

    1955-01-01

    The use of nuclear reactor for energy production induces the installation of automatic control systems which need to be safe enough and can adapt to the industrial scale of energy production. These automatic control systems have to insure the constancy of power level and adjust the power produced to the energy demand. Two functioning modes are considered: nuclear plant connected up to other electric production systems as hydraulic or thermic plants or nuclear plants functioning on an independent network. For nuclear plants connected up with other production plants, xenon poisoning and operating cost lead to keep working at maximum power the nuclear reactors. Thus, the power modulation control system will not be considered and only start-up control, safety control, and control systems will be automated. For nuclear power plants working on an independent network, the power modulation control system is needed to economize fuel. It described the automated control system for reactors functioning with constant power: a power measurement system constituted of an ionization chamber and a direct-current amplifier will control the steadfastness of the power produced. For reactors functioning with variable power, the automated power control system will allow to change the power and maintain it steady with all the necessary safety and will control that working conditions under P max and R max (maximum power and maximum reactivity). The effects of temperature and xenon poisoning will also be discussed. Safety systems will be added to stop completely the functioning of the reactor if P max is reached. (M.P.)

  5. Objective ARX Model Order Selection for Multi-Channel Human Operator Identification

    NARCIS (Netherlands)

    Roggenkämper, N; Pool, D.M.; Drop, F.M.; van Paassen, M.M.; Mulder, M.

    2016-01-01

    In manual control, the human operator primarily responds to visual inputs but may elect to make use of other available feedback paths such as physical motion, adopting a multi-channel control strategy. Hu- man operator identification procedures generally require a priori selection of the model

  6. Enhanced throughput for infrared automated DNA sequencing

    Science.gov (United States)

    Middendorf, Lyle R.; Gartside, Bill O.; Humphrey, Pat G.; Roemer, Stephen C.; Sorensen, David R.; Steffens, David L.; Sutter, Scott L.

    1995-04-01

    Several enhancements have been developed and applied to infrared automated DNA sequencing resulting in significantly higher throughput. A 41 cm sequencing gel (31 cm well- to-read distance) combines high resolution of DNA sequencing fragments with optimized run times yielding two runs per day of 500 bases per sample. A 66 cm sequencing gel (56 cm well-to-read distance) produces sequence read lengths of up to 1000 bases for ds and ss templates using either T7 polymerase or cycle-sequencing protocols. Using a multichannel syringe to load 64 lanes allows 16 samples (compatible with 96-well format) to be visualized for each run. The 41 cm gel configuration allows 16,000 bases per day (16 samples X 500 bases/sample X 2 ten hour runs/day) to be sequenced with the advantages of infrared technology. Enhancements to internal labeling techniques using an infrared-labeled dATP molecule (Boehringer Mannheim GmbH, Penzberg, Germany; Sequenase (U.S. Biochemical) have also been made. The inclusion of glycerol in the sequencing reactions yields greatly improved results for some primer and template combinations. The inclusion of (alpha) -Thio-dNTP's in the labeling reaction increases signal intensity two- to three-fold.

  7. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  8. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. 3S-R10 automated RBS system

    International Nuclear Information System (INIS)

    Norton, G.A.; Schroeder, J.B.; Klody, G.M.; Strathman, M.D.

    1989-01-01

    The NEC 3S-R10 automated RBS spectrometer system includes the features required for routine application of Rutherford backscattering (RBS) and related techniques for materials analysis in both research and industrial settings. The NEC Model 3SDH Pelletron accelerator system provides stable, monoenergetic beams of helium ions up to 3.3 MeV and protons to 2.2 MeV and has heavy ion capability. The analytical end station is the fully computerized Charles Evans and Associates Model RBS-400. Automated features include sample positioning (precision 4-axis goniometer), channeling alignment, polar plot generation, and data acquisition and reduction. Computer automation of accelerator and chamber functions includes storage and recall of operating parameters. Unattended data acquisition, e.g., overnight or over a weekend, is possible for up to 100 samples per batch for random orientation, rotating random or channeling analyses at any sample location. Single samples may be up to 50 cm in diameter. A laser for sample alignment and a TV for video monitoring are included. Simultaneous detection (up to 4 detectors) at normal and grazing angles, external control of grazing angle detector position, and transmission scattering capabiltiy enhance system flexibility. The system is also compatible with PIXE, NRA, and hydrogen forward-backscattering analyses. Data reduction is part of the computer system, which features displays (several formats) and manipulation of up to five spectra at one time using constant multipliers or point by point operations between spectra. (orig.)

  10. 3D Multi-Channel Networked Visualization System for National LambdaRail, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Multichannel virtual reality visualization is the future of complex simulation with a large number of visual channels rendered and transmitted over high-speed...

  11. Calibration OGSE for a multichannel radiometer for Mars atmosphere studies

    Science.gov (United States)

    Jiménez, J. J.; Álvarez, F. J.; Gonzalez-Guerrero, M.; Apéstigue, V.; Martin, I.; Fernández, J. M.; Fernán, A. A.; Arruego, I.

    2017-09-01

    This work describes several OGSEs (Optical Ground Support Equipment) developed by INTA (Spanish Institute of Aerospace Technology - Instituto Nacional de Técnica Aeroespacial) for the calibration and characterization of their self-manufactured multichannel radiometers (Solar Irradiance Sensors - SIS) for planetary atmospheric studies in the frame of some Martian missions at which INTA is participating.

  12. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  13. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  14. ON SCALAR MESONS FROM THE COMBINED ANALYSIS OF MULTI-CHANNEL pi pi SCATTERING AND J/psi DECAYS

    Czech Academy of Sciences Publication Activity Database

    Surovtsev, Yu .S.; Bydžovský, Petr; Gutsche, T.; Lyubovitskij, V. E.

    2011-01-01

    Roč. 26, 3-4 (2011), s. 610-612 ISSN 0217-751X. [11th International Workshop on Meson Production , Properties and Interaction. Krakow, 10.06.2010-15.06.2010] R&D Projects: GA ČR GA202/08/0984 Institutional research plan: CEZ:AV0Z10480505 Keywords : Multi-channel pion-pion scattering * scalar-isoscalar resonances * multichannel analysis Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.053, year: 2011

  15. Metasurface for multi-channel terahertz beam splitters and polarization rotators

    Science.gov (United States)

    Zang, XiaoFei; Gong, HanHong; Li, Zhen; Xie, JingYa; Cheng, QingQing; Chen, Lin; Shkurinov, Alexander P.; Zhu, YiMing; Zhuang, SongLin

    2018-04-01

    Terahertz beam splitters and polarization rotators are two typical devices with wide applications ranging from terahertz communication to system integration. However, they are faced with severe challenges in manipulating THz waves in multiple channels, which is desirable for system integration and device miniaturization. Here, we propose a method to design ultra-thin multi-channel THz beam splitters and polarization rotators simultaneously. The reflected beams are divided into four beams with nearly the same density under illumination of linear-polarized THz waves, while the polarization of reflected beams in each channel is modulated with a rotation angle or invariable with respect to the incident THz waves, leading to the multi-channel polarization rotator (multiple polarization rotation in the reflective channels) and beam splitter, respectively. Reflective metasurfaces, created by patterning metal-rods with different orientations on a polyimide film, were fabricated and measured to demonstrate these characteristics. The proposed approach provides an efficient way of controlling polarization of THz waves in various channels, which significantly simplifies THz functional devices and the experimental system.

  16. Improvement of Swirl Chamber Structure of Swirl-Chamber Diesel Engine Based on Flow Field Characteristics

    Directory of Open Access Journals (Sweden)

    Wenhua Yuan

    2014-10-01

    Full Text Available In order to improve combustion characteristic of swirl chamber diesel engine, a simulation model about a traditional cylindrical flat-bottom swirl chamber turbulent combustion diesel engine was established within the timeframe of the piston motion from the bottom dead centre (BDC to the top dead centre (TDC with the fluent dynamic mesh technique and flow field vector of gas in swirl chamber and cylinder; the pressure variation and temperature variation were obtained and a new type of swirl chamber structure was proposed. The results reveal that the piston will move from BDC; air in the cylinder is compressed into the swirl chamber by the piston to develop a swirl inside the chamber, with the ongoing of compression; the pressure and temperature are also rising gradually. Under this condition, the demand of diesel oil mixing and combusting will be better satisfied. Moreover, the new structure will no longer forma small fluid retention zone at the lower end outside the chamber and will be more beneficial to the mixing of fuel oil and air, which has presented a new idea and theoretical foundation for the design and optimization of swirl chamber structure and is thus of good significance of guiding in this regard.

  17. Scene text detection by leveraging multi-channel information and local context

    Science.gov (United States)

    Wang, Runmin; Qian, Shengyou; Yang, Jianfeng; Gao, Changxin

    2018-03-01

    As an important information carrier, texts play significant roles in many applications. However, text detection in unconstrained scenes is a challenging problem due to cluttered backgrounds, various appearances, uneven illumination, etc.. In this paper, an approach based on multi-channel information and local context is proposed to detect texts in natural scenes. According to character candidate detection plays a vital role in text detection system, Maximally Stable Extremal Regions(MSERs) and Graph-cut based method are integrated to obtain the character candidates by leveraging the multi-channel image information. A cascaded false positive elimination mechanism are constructed from the perspective of the character and the text line respectively. Since the local context information is very valuable for us, these information is utilized to retrieve the missing characters for boosting the text detection performance. Experimental results on two benchmark datasets, i.e., the ICDAR 2011 dataset and the ICDAR 2013 dataset, demonstrate that the proposed method have achieved the state-of-the-art performance.

  18. Development of data acquisition and analysis software for multichannel detectors

    International Nuclear Information System (INIS)

    Chung, Y.

    1988-06-01

    This report describes the development of data acquisition and analysis software for Apple Macintosh computers, capable of controlling two multichannel detectors. With the help of outstanding graphics capabilities, easy-to-use user interface, and several other built-in convenience features, this application has enhanced the productivity and the efficiency of data analysis. 2 refs., 6 figs

  19. A high dutycycle low cost multichannel analyser for electron spectroscopy

    International Nuclear Information System (INIS)

    Norell, K.E.; Baltzer, P.

    1983-03-01

    A high dutycycle multichannel analyzer has been designed and used in time-of-flight electron spectroscopy. The memory capacity is 64k counts. The number of channels is 8192 with a time resolution of 100 ns. An oscilloscope is used to display the spectra synchronous with the counting. The unit has been built with standard electronic components. (author)

  20. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  1. The effects of automated artifact removal algorithms on electroencephalography-based Alzheimer’s disease diagnosis

    Directory of Open Access Journals (Sweden)

    Raymundo eCassani

    2014-03-01

    Full Text Available Over the last decade, electroencephalography (EEG has emerged as a reliable tool for the diagnosis of cortical disorders such as Alzheimer's disease (AD. EEG signals, however, are susceptible to several artifacts, such as ocular, muscular, movement, and environmental. To overcome this limitation, existing diagnostic systems commonly depend on experienced clinicians to manually select artifact-free epochs from the collected multi-channel EEG data. Manual selection, however, is a tedious and time-consuming process, rendering the diagnostic system ``semi-automated. Notwithstanding, a number of EEG artifact removal algorithms have been proposed in the literature. The (disadvantages of using such algorithms in automated AD diagnostic systems, however, have not been documented; this paper aims to fill this gap. Here, we investigate the effects of three state-of-the-art automated artifact removal (AAR algorithms (both alone and in combination with each other on AD diagnostic systems based on four different classes of EEG features, namely, spectral, amplitude modulation rate of change, coherence, and phase. The three AAR algorithms tested are statistical artifact rejection (SAR, blind source separation based on second order blind identification and canonical correlation analysis (BSS-SOBI-CCA, and wavelet enhanced independent component analysis (wICA. Experimental results based on 20-channel resting-awake EEG data collected from 59 participants (20 patients with mild AD, 15 with moderate-to-severe AD, and 24 age-matched healthy controls showed the wICA algorithm alone outperforming other enhancement algorithm combinations across three tasks: diagnosis (control vs. mild vs. moderate, early detection (control vs. mild, and disease progression (mild vs. moderate, thus opening the doors for fully-automated systems that can assist clinicians with early detection of AD, as well as disease severity progression assessment.

  2. Creating the Deep Space Environment for Testing the James Webb Space Telescope at NASA Johnson Space Center's Chamber A

    Science.gov (United States)

    Homan, Jonathan L.; Cerimele, Mary P.; Montz, Michael E.; Bachtel, Russell; Speed, John; O'Rear, Patrick

    2013-01-01

    Chamber A is the largest thermal vacuum chamber at the Johnson Space Center and is one of the largest space environment chambers in the world. The chamber is 19.8 m (65 ft.) in diameter and 36.6 m (120 ft.) tall and is equipped with cryogenic liquid nitrogen panels (shrouds) and gaseous helium shrouds to create a simulated space environment. It was originally designed and built in the mid 1960 s to test the Apollo Command and Service Module and several manned tests were conducted on that spacecraft, contributing to the success of the program. The chamber has been used since that time to test spacecraft active thermal control systems, Shuttle DTO, DOD, and ESA hardware in simulated Low Earth Orbit (LEO) conditions. NASA is now moving from LEO towards exploration of locations with environments approaching those of deep space. Therefore, Chamber A has undergone major modifications to enable it to simulate these deeper space environments. Environmental requirements were driven, and modifications were funded by the James Webb Space Telescope program, and this telescope, which will orbit Solar/Earth L2, will be the first test article to benefit from the chamber s new capabilities. To accommodate JWST, the Chamber A high vacuum system has been modernized, additional LN2 shrouds have been installed, the liquid nitrogen system has been modified to minimize dependency on electrical power and increase its reliability, a new helium shroud/refrigeration system has been installed to create a colder more stable and uniform heat sink, and the controls have been updated to increase the level of automation and improve operator interfaces. Testing of these major modifications was conducted in August of 2012 and this initial test was very successful, with all major systems exceeding their performance requirements. This paper will outline the changes in overall environmental requirements, discuss the technical design data that was used in the decisions leading to the extensive

  3. Creating the Deep Space Environment for Testing the James Webb Space Telescope at the Johnson Space Center's Chamber A

    Science.gov (United States)

    Homan, Jonathan L.; Cerimele, Mary P.; Montz, Michael E.

    2012-01-01

    Chamber A is the largest thermal vacuum chamber at the Johnson Space Center and is one of the largest space environment chambers in the world. The chamber is 19.8 m (65 ft) in diameter and 36.6 m (120 ft) tall and is equipped with cryogenic liquid nitrogen panels (shrouds) and gaseous helium shrouds to create a simulated space environment. It was originally designed and built in the mid 1960's to test the Apollo Command and Service Module and several manned tests were conducted on that spacecraft, contributing to the success of the program. The chamber has been used since that time to test spacecraft active thermal control systems, Shuttle DTO, DOD, and ESA hardware in simulated Low Earth Orbit (LEO) conditions. NASA is now moving from LEO towards exploration of locations with environments approaching those of deep space. Therefore, Chamber A has undergone major modifications to enable it to simulate these deeper space environments. Environmental requirements were driven, and the modifications were funded, by the James Webb Space Telescope program, and this telescope which will orbit Solar/Earth L2, will be the first test article to benefit from the chamber s new capabilities. To accommodate JWST, the Chamber A high vacuum system has been modernized, additional LN2 shrouds have been installed, the liquid nitrogen system has been modified to remove dependency on electrical power and increase its reliability, a new helium shroud/refrigeration system has been installed to create a colder more stable and uniform heat sink and, the controls have been updated to increase the level of automation and improve operator interfaces. Testing of these major modifications was conducted in August 2012 and this initial test was very successful, with all major systems exceeding their performance requirements. This paper will outline the changes in the overall environmental requirements, discuss the technical design data that was used in the decisions leading to the extensive

  4. Development of a Multichannel Analyzer for modular ADCs

    International Nuclear Information System (INIS)

    Bannos Rodriguez, U.; Diaz Castro, M.; Rivero Ramirez, D.

    2013-01-01

    This paper describes the design and construction of a multichannel analyzer with USB interface from ADC module of the Fast ComTec 7074. One PIC18F4550 microprocessor from Microchip, one CPLD isPLSI 1032E from Lattice and one 32Kx8 SRAM memory were used. It also includes details of the programming circuitry and development of program acquisition, storage and display of the spectra using the Qt libraries. Finally, preliminary tests to the device are show. (Author)

  5. Mimicking multi-channel scattering with single-channel approaches

    OpenAIRE

    Grishkevich, Sergey; Schneider, Philipp-Immanuel; Vanne, Yulian V.; Saenz, Alejandro

    2009-01-01

    The collision of two atoms is an intrinsic multi-channel (MC) problem as becomes especially obvious in the presence of Feshbach resonances. Due to its complexity, however, single-channel (SC) approximations, which reproduce the long-range behavior of the open channel, are often applied in calculations. In this work the complete MC problem is solved numerically for the magnetic Feshbach resonances (MFRs) in collisions between generic ultracold 6Li and 87Rb atoms in the ground state and in the ...

  6. Astronomical observations with the optical multichannel analyser of the Sao Paulo University

    Energy Technology Data Exchange (ETDEWEB)

    Codina-Landaberry, S J; de Freitas Pacheco, J A [Universidade Mackenzie, Sao Paulo (Brazil). Centro de Radio-Astronomia e Astrofisica

    1979-03-01

    The first astronomical observations made with the optical multichannel analyser (OMA) of the Sao Paulo University is reported. A detailed description of the instrumentation is given as well as the results derived from the observation of some emission nebulae.

  7. The Role of Multichannel Marketing in Customer Retention and Loyalty: Study in Emerald Bank Customer in Indonesia

    OpenAIRE

    Ambarwati Ambarwati; Djumilah Zain Hadiwidjojo; Achmad Sudiro; Fatchur Rohman

    2015-01-01

    Attention on the relationship between customer retention, customer loyalty, and customer satisfaction that serves as "seed" of customer loyalty highlight the important factors for multichannel management. With the growing trends of people in investing their money in bank for securities need to be responded by the marketing department to create better marketing strategies. The purpose of this study is to examine and explain the effect of a multichannel bank on emerald customers retention   in ...

  8. A New Multichannel Spectral Imaging Laser Scanning Confocal Microscope

    Directory of Open Access Journals (Sweden)

    Yunhai Zhang

    2013-01-01

    Full Text Available We have developed a new multichannel spectral imaging laser scanning confocal microscope for effective detection of multiple fluorescent labeling in the research of biological tissues. In this paper, the design and key technologies of the system are introduced. Representative results on confocal imaging, 3-dimensional sectioning imaging, and spectral imaging are demonstrated. The results indicated that the system is applicable to multiple fluorescent labeling in biological experiments.

  9. Multichannel Baseband Processor for Wideband CDMA

    Directory of Open Access Journals (Sweden)

    Jim Lin

    2005-07-01

    Full Text Available The system architecture of the cellular base station modem engine (CBME is described. The CBME is a single-chip multichannel transceiver capable of processing and demodulating signals from multiple users simultaneously. It is optimized to process different classes of code-division multiple-access (CDMA signals. The paper will show that through key functional system partitioning, tightly coupled small digital signal processing cores, and time-sliced reuse architecture, CBME is able to achieve a high degree of algorithmic flexibility while maintaining efficiency. The paper will also highlight the implementation and verification aspects of the CBME chip design. In this paper, wideband CDMA is used as an example to demonstrate the architecture concept.

  10. Multichannel Seismic Reflection - SCAR- Antarctic Penn. 1987-88 SDLS CD-ROM vol 27

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1987-88 in the Antarctica Peninsula region, by Petrobras, Brazil. The following...

  11. Multichannel Seismic Reflection - SCAR- Antarctic Penn. 1987-88 SDLS CD-ROM vol 26

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1987-88 in the Antarctica Peninsula region, by Petrobras, Brazil. The following...

  12. Personalized multi-channel headphone sound reproduction based on active noise cancellation

    NARCIS (Netherlands)

    Schobben, D.W.E.; Aarts, R.M.

    2005-01-01

    A system for headphone signal processing is discussed which gives a listener the same impression as listening to a multi-channel loudspeaker set-up. It is important that this processing is optimized for each individual listener. If this is not the case, large localization errors may occur. In the

  13. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  14. Automated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA.

    Science.gov (United States)

    Sai, Chong Yeh; Mokhtar, Norrima; Arof, Hamzah; Cumming, Paul; Iwahashi, Masahiro

    2018-05-01

    Brain electrical activity recordings by electroencephalography (EEG) are often contaminated with signal artifacts. Procedures for automated removal of EEG artifacts are frequently sought for clinical diagnostics and brain-computer interface applications. In recent years, a combination of independent component analysis (ICA) and discrete wavelet transform has been introduced as standard technique for EEG artifact removal. However, in performing the wavelet-ICA procedure, visual inspection or arbitrary thresholding may be required for identifying artifactual components in the EEG signal. We now propose a novel approach for identifying artifactual components separated by wavelet-ICA using a pretrained support vector machine (SVM). Our method presents a robust and extendable system that enables fully automated identification and removal of artifacts from EEG signals, without applying any arbitrary thresholding. Using test data contaminated by eye blink artifacts, we show that our method performed better in identifying artifactual components than did existing thresholding methods. Furthermore, wavelet-ICA in conjunction with SVM successfully removed target artifacts, while largely retaining the EEG source signals of interest. We propose a set of features including kurtosis, variance, Shannon's entropy, and range of amplitude as training and test data of SVM to identify eye blink artifacts in EEG signals. This combinatorial method is also extendable to accommodate multiple types of artifacts present in multichannel EEG. We envision future research to explore other descriptive features corresponding to other types of artifactual components.

  15. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized through- put maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  16. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2008-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized throughput maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  17. Astronomical observations with the optical multichannel analyser of the Sao Paulo University

    International Nuclear Information System (INIS)

    Codina-Landaberry, S.J.; Freitas Pacheco, J.A. de

    1979-01-01

    The first astronomical observations made with the optical multichannel analyser (OMA) of the Sao Paulo University is reported. A detailed description of the instrumentation is given as well as the results derived from the observation of some emission nebulae [pt

  18. A high-throughput, multi-channel photon-counting detector with picosecond timing

    Science.gov (United States)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  19. A high-throughput, multi-channel photon-counting detector with picosecond timing

    International Nuclear Information System (INIS)

    Lapington, J.S.; Fraser, G.W.; Miller, G.M.; Ashton, T.J.R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  20. Compact and cost-effective multi-channel optical spectrometer for fine FBG sensing in IoT technology

    Science.gov (United States)

    Konishi, Tsuyoshi; Yamasaki, Yu

    2018-02-01

    Optical fiber sensor networks have attracted much attention in IoT technology and a fiber Bragg grating is one of key sensor devices there because of their advantages in a high affinity for optical fiber networks, compactness, immunity to electromagnetic interference and so on. Nevertheless, its sensitivity is not always satisfactory so as to be usable together with widespread cost-effective multi-channel spectrometers. In this paper, we introduce a new cost-effective approach for a portable multi-channel spectrometer with high spectral resolution and demonstrates some preliminary experimental results for fine FBG sensing.

  1. Spatial aspects of sound quality - and by multichannel systems subjective assessment of sound reproduced by stereo

    DEFF Research Database (Denmark)

    Choisel, Sylvain

    the fidelity with which sound reproduction systems can re-create the desired stereo image, a laser pointing technique was developed to accurately collect subjects' responses in a localization task. This method is subsequently applied in an investigation of the effects of loudspeaker directivity...... on the perceived direction of panned sources. The second part of the thesis addresses the identification of auditory attributes which play a role in the perception of sound reproduced by multichannel systems. Short musical excerpts were presented in mono, stereo and several multichannel formats to evoke various...

  2. Development and implementation of own software for dosimetry multichannel film; Desarrollo e implementacion de un software propio para la dosimetria multicanal con pelicula radiocromica EBT2

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez Feltstrom, D.; Reyes Garcia, R.; Luis Simon, F. J.; Carrasco Herrera, M.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-07-01

    The objective of this work is to develop its own software for multichannel film dosimetry Radiochromic EBT2. Compare the results obtained with its use in multichannel and single-channel dosimetry. Check that the multi-channel dosimetry eliminates much of the artifacts caused by dirt, fingerprints, scratches, etc. Radiochromic in film and scanner devices. (Author)

  3. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...

  4. Multichannel Seismic Reflection Data - SCAR - Ross Sea - 1987, SDLS CD-ROM vol 13

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during the 1987 field season in the Ross Sea, Antarctica, by SEVMORGEOLOGIA, RUSSIA. The...

  5. Multichannel Seismic Reflection Data - SCAR - Ross Sea - 1980, SDLS CD-ROM vol 3

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from four lines recorded during 1980 in the Ross Sea, Antarctica, by the Bundesanstalt fur...

  6. Multichannel Seismic Reflection Data - SCAR - Ross Sea - 1980, SDLS, CD-ROM vol 4

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from seven lines recorded during 1980 in the Ross Sea, Antarctica, by the Bundesanstalt fur...

  7. Multichannel Seismic Reflection Data - SCAR - Ross Sea - 1989, SDLS CD-ROM vol 14

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1989 field season in the Ross Sea, Antarctica, by the SEVMORGEOLOGIA, RUSSIS. The...

  8. Multichannel Seismic Reflection Data - SCAR - Ross Sea 1980, SDLS, CD-ROM vol 5

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from eleven lines recorded during 1980 in the Ross Sea, Antarctica, by the Bundesanstalt fur...

  9. Multichannel Seismic Reflection Data - SCAR - Wilkes Land, 1983, SDLS CD-ROM vol 10

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from thirteen lines recorded during 1983 off Wilkes Island, Antarctica, by the Japan National Oil...

  10. Multichannel Seismic Reflection Data - SCAR - Wilkes Land 1982, SDLS CD-ROM vol 11

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from sixteen lines recorded during 1982 off Wilkes Island, Antarctica, by the Institut Francais du...

  11. Development of a multichannel dosimeter for radiotherapy; Desenvolvimento de um dosimetro multicanal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Claudio Jose Mesquita

    2000-06-01

    In radiotherapy, verification of the patient dose is of great important for the success of the treatment. Uncertainties in the evaluation of this dose can produce serious complications such as the loss of the control of the disease and damage to normal tissue. Semiconductor detectors present advantages over other types of radiation detectors such as ionization chambers and thermoluminescent dosimeters including small dimensions, high sensitivity and fast response. In this work, a multichannel dosimetric system is linear with dose, for a 6 MV x-ray beam and also with a beam of cobalt-60 gamma rays. The coefficients of determination of the calibration curves were better then 0,9998 in all cases. The four sensors presented similar response with the dose for different field sizes. The variation of the response was smaller than 1%. In a related study, depth dose was measured, and the results showed a good agreement compared to theoretical values. The angular response of the detectors showed a variation of 7% for angles of 45 deg C. Using the Anderson Random phantom, dose at the isocenter was determined from measurements of the surface dose. From the results obtained it can be concluded that the dosimetric system developed is adequate for the evaluation of many parameters in radiation fields used in radiotherapy. This system can be used to measure the patient entrance dose under treatment conditions, and the equipment can be used in the radiotherapy quality assurance program. (author)

  12. An Improved Cloud Classification Algorithm for China's FY-2C Multi-Channel Images Using Artificial Neural Network.

    Science.gov (United States)

    Liu, Yu; Xia, Jun; Shi, Chun-Xiang; Hong, Yang

    2009-01-01

    The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China's first operational geostationary meteorological satellite FengYun-2C (FY-2C) data. First, the capabilities of six widely-used Artificial Neural Network (ANN) methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA) and a Support Vector Machine (SVM), using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm) imagery. The result shows that: (1) ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2) among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM) and Probabilistic Neural Network (PNN). Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  13. Multichannel Seismic Reflection Data - SCAR - Weddell Sea - 1978, SDLS CD-ROM vol 19

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1978 in the Weddell Sea and Queen Maud Land, Antarctica, by the Bundesanstalt fur...

  14. Multichannel Seismic Reflection Data - SCAR, Ross Sea - 1982-1983, CD-ROM vol 9

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from fourteen lines recorded during 1982 in the Ross Sea and Wilkes Island, Antarctica, by the...

  15. Multichannel Seismic Reflection Data - SCAR - Weddell Sea - 1978, SDLS CD-ROM vol 18

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1978 in the Weddell Sea and Queen Maud Land, Antarctica, by the Bundesanstalt fur...

  16. Multichannel Seismic Reflection Data - SCAR - Weddell Sea - 1978, SDLS CD-ROM vol 17

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1978 in the Weddell Sea and Queen Maud Land, Antarctica, by the Bundesanstalt fur...

  17. Multichannel Seismic Reflection Data - SCAR - Antarctic Peninsula - 1985, SDLS CD-ROM vol 16

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1985 field season along the north side of the Antarctic-Peninsula by the British...

  18. Multichannel Seismic Reflection Data - SCAR - Ross Sea 1982, SDLS CD-ROM vol 12

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from seven lines recorded during 1982 in the Ross Sea, Antarctica, by the Institut Francais du...

  19. A new implementation of multichannel radiochromic film dosimetry; Una nueva implementacion del analisis multicanal para la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Tores Olombrada, M. V. de

    2014-07-01

    The aims of this paper are to carry out a new implementation of the multichannel radiochromic film dosimetry (Micke A, Lewis D, Yu X. Multichannel film dosimetry with nonuniformity correction. Med Phys 2011;38:2523-34), to quantify the variation in gamma index as compared to the single channel film dosimetry, and to determine if the procedure achieves similar results by means of a different scanner that the one used by Micke et al. Radiochromic EBT2 films and a Microtek 9000 XL scanner were used. Our procedure simplifies the system calibration splitting it into two factors, manufactured batch and digitalization specific. Absorbed dose spatial distributions from an open radiotherapy beam without any modulation and 20 IMRT treatments were determined. Their gamma index maps were calculated and a comparison of the results from single channel and multichannel dosimetry was performed. A 5% mean increase in concordance was obtained by using the multichannel film dosimetry. Our results are similar to those reported by Micke et al. even though we are using a different scanner. (Author)

  20. The Single- and Multichannel Audio Recordings Database (SMARD)

    DEFF Research Database (Denmark)

    Nielsen, Jesper Kjær; Jensen, Jesper Rindom; Jensen, Søren Holdt

    2014-01-01

    A new single- and multichannel audio recordings database (SMARD) is presented in this paper. The database contains recordings from a box-shaped listening room for various loudspeaker and array types. The recordings were made for 48 different configurations of three different loudspeakers and four...... different microphone arrays. In each configuration, 20 different audio segments were played and recorded ranging from simple artificial sounds to polyphonic music. SMARD can be used for testing algorithms developed for numerous application, and we give examples of source localisation results....

  1. Improvement of force-sensor-based heart rate estimation using multichannel data fusion.

    Science.gov (United States)

    Bruser, Christoph; Kortelainen, Juha M; Winter, Stefan; Tenhunen, Mirja; Parkka, Juha; Leonhardt, Steffen

    2015-01-01

    The aim of this paper is to present and evaluate algorithms for heartbeat interval estimation from multiple spatially distributed force sensors integrated into a bed. Moreover, the benefit of using multichannel systems as opposed to a single sensor is investigated. While it might seem intuitive that multiple channels are superior to a single channel, the main challenge lies in finding suitable methods to actually leverage this potential. To this end, two algorithms for heart rate estimation from multichannel vibration signals are presented and compared against a single-channel sensing solution. The first method operates by analyzing the cepstrum computed from the average spectra of the individual channels, while the second method applies Bayesian fusion to three interval estimators, such as the autocorrelation, which are applied to each channel. This evaluation is based on 28 night-long sleep lab recordings during which an eight-channel polyvinylidene fluoride-based sensor array was used to acquire cardiac vibration signals. The recruited patients suffered from different sleep disorders of varying severity. From the sensor array data, a virtual single-channel signal was also derived for comparison by averaging the channels. The single-channel results achieved a beat-to-beat interval error of 2.2% with a coverage (i.e., percentage of the recording which could be analyzed) of 68.7%. In comparison, the best multichannel results attained a mean error and coverage of 1.0% and 81.0%, respectively. These results present statistically significant improvements of both metrics over the single-channel results (p < 0.05).

  2. High-pressure duo-multichannel soft x-ray spectrometer for tokamak plasma diagnostics

    International Nuclear Information System (INIS)

    Schwob, J.L.; Wouters, A.W.; Suckewer, S.

    1987-03-01

    A high-resolution, time-resolving soft X-ray multichannel spectrometer (SOXMOS) that permits the simultaneous measurement of emission in two different spectral ranges has been developed and tested extensively for tokamak plasma diagnostics. The basic instrument is a high-resolution, interferometrically adjusted, extreme grazing incidence Schwob-Fraenkel duochromator. The instrument is equipped with two multichannel detectors that are adjusted interferometrically and scan along the Rowland circle. Each consists of an MgF 2 coated, funneled microchannel plate, associated with a phosphor screen image intensifier that is coupled to a 1024-element photodiode array by a flexible fibrer optic conduit. The total wavelength coverage of the instrument is 5 to 340 0 A with a measured resolution (FWHM) of about 0.2 A when equipped with a 600 g/mm grating, and 5 to 85 A with a resolution of about 0.06 A using a 2400 g/mm grating. The simultaneous spectral coverage of each detector varies from 15 A at the short wavelength limit to 70 A at the long wavelength limit with the lower dispersion grating. The minimum read-out time for a full spectral portion is 17 ms, but several individual lines can be measured with 1 ms time resolution by selected pixel readout. Higher time resolution can be achieved by replacing one multichannel detector with a single channel electron multiplier detector. Examples of data from the PLT and TFTR tokamaks are presented to illustrate the instrument's versatility, high spectral resolution, and high signal-to-noise ratio even in the 10 A region. 44 refs., 20 figs

  3. Creating the Deep Space Environment for Testing the James Webb Space Telescope (JWST) at NASA Johnson Space Center's Chamber A

    Science.gov (United States)

    Homan, Jonathan L.; Cerimele, Mary P.; Montz, Michael E.; Bachtel, Russell; Speed, John; O'Rear, Patrick

    2013-01-01

    Chamber A is the largest thermal vacuum chamber at the Johnson Space Center and is one of the largest space environment chambers in the world. The chamber is 19.8 m (65 ft) in diameter and 36.6 m (120 ft) tall and is equipped with cryogenic liquid nitrogen panels (shrouds) and gaseous helium shrouds to create a simulated space environment. It was originally designed and built in the mid 1960 s to test the Apollo Command and Service Module and several manned tests were conducted on that spacecraft, contributing to the success of the program. The chamber has been used since that time to test spacecraft active thermal control systems, Shuttle DTO, DOD, and ESA hardware in simulated Low Earth Orbit (LEO) conditions. NASA is now moving from LEO towards exploration of locations with environments approaching those of deep space. Therefore, Chamber A has undergone major modifications to enable it to simulate these deeper space environments. Environmental requirements were driven, and modifications were funded by the James Webb Space Telescope program, and this telescope which will orbit Solar/Earth L2, will be the first test article to benefit from the chamber s new capabilities. To accommodate JWST, the Chamber A high vacuum system has been modernized, additional LN2 shrouds have been installed, the liquid nitrogen system has been modified to remove dependency on electrical power and increase its reliability, a new helium shroud/refrigeration system has been installed to create a colder more stable and uniform heat sink, and the controls have been updated to increase the level of automation and improve operator interfaces. Testing of these major modifications was conducted in August of 2012 and this initial test was very successful, with all major systems exceeding their performance requirements. This paper will outline the changes in overall environmental requirements, discuss the technical design data that was used in the decisions leading to the extensive modifications

  4. On multichannel film dosimetry with channel-independent perturbations

    International Nuclear Information System (INIS)

    Méndez, I.; Peterlin, P.; Hudej, R.; Strojnik, A.; Casar, B.

    2014-01-01

    Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth byMicke et al. [“Multichannel film dosimetry with nonuniformity correction,” Med. Phys. 38, 2523–2534 (2011)] and Mayer et al. [“Enhanced dosimetry procedures and assessment for EBT2 radiochromic film,” Med. Phys. 39, 2147–2155 (2012)]. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke–Mayer method, uniform distribution, and truncated normal distribution. A closed-form formula to calculate film doses and the associated type B uncertainty for all four models was deduced. To evaluate the models, film dose distributions were compared with planned and measured dose distributions. At the same time, several elements of the dosimetry process were compared: film type EBT2 versus EBT3, different waiting-time windows, reflection mode versus transmission mode scanning, and planned versus measured dose distribution for film calibration and for γ-index analysis. The methods and the models described in this study are publicly accessible through IRISEU. Alpha 1.1 ( http://www.iriseu.com ). IRISEU. is a cloud computing web application for calibration and dosimetry of radiochromic films. Results: The truncated normal distribution model provided the best agreement between film and reference doses, both for calibration and γ-index verification, and proved itself superior to both the weighted mean model, which neglects correlations between the channels, and the Micke–Mayer model, whose accuracy depends on the properties of the sensitometric curves. With respect to the selection of dosimetry protocol, no significant differences were found between transmission and reflection mode scanning

  5. On multichannel film dosimetry with channel-independent perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Méndez, I., E-mail: nmendez@onko-i.si; Peterlin, P.; Hudej, R.; Strojnik, A.; Casar, B. [Department of Medical Physics, Institute of Oncology Ljubljana, Zaloška cesta 2, Ljubljana 1000 (Slovenia)

    2014-01-15

    Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth byMicke et al. [“Multichannel film dosimetry with nonuniformity correction,” Med. Phys. 38, 2523–2534 (2011)] and Mayer et al. [“Enhanced dosimetry procedures and assessment for EBT2 radiochromic film,” Med. Phys. 39, 2147–2155 (2012)]. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke–Mayer method, uniform distribution, and truncated normal distribution. A closed-form formula to calculate film doses and the associated type B uncertainty for all four models was deduced. To evaluate the models, film dose distributions were compared with planned and measured dose distributions. At the same time, several elements of the dosimetry process were compared: film type EBT2 versus EBT3, different waiting-time windows, reflection mode versus transmission mode scanning, and planned versus measured dose distribution for film calibration and for γ-index analysis. The methods and the models described in this study are publicly accessible through IRISEU. Alpha 1.1 ( http://www.iriseu.com ). IRISEU. is a cloud computing web application for calibration and dosimetry of radiochromic films. Results: The truncated normal distribution model provided the best agreement between film and reference doses, both for calibration and γ-index verification, and proved itself superior to both the weighted mean model, which neglects correlations between the channels, and the Micke–Mayer model, whose accuracy depends on the properties of the sensitometric curves. With respect to the selection of dosimetry protocol, no significant differences were found between transmission and reflection mode scanning

  6. Modeling and optimization of the multichannel spark discharge

    International Nuclear Information System (INIS)

    Zhang Zhi-Bo; Wu Yun; Jia Min; Song Hui-Min; Li Ying-Hong; Sun Zheng-Zhong

    2017-01-01

    This paper reports a novel analytic model of this multichannel spark discharge, considering the delay time in the breakdown process, the electric transforming of the discharge channel from a capacitor to a resistor induced by the air breakdown, and the varying plasma resistance in the discharge process. The good agreement between the experimental and the simulated results validated the accuracy of this model. Based on this model, the influence of the circuit parameters on the maximum discharge channel number (MDCN) is investigated. Both the input voltage amplitude and the breakdown voltage threshold of each discharge channel play a critical role. With the increase of the input voltage and the decrease of the breakdown voltage, the MCDN increases almost linearly. With the increase of the discharge capacitance, the MDCN first rises and then remains almost constant. With the increase of the circuit inductance, the MDCN increases slowly but decreases quickly when the inductance increases over a certain value. There is an optimal value of the capacitor connected to the discharge channel corresponding to the MDCN. Finally, based on these results, to shorten the discharge time, a modified multichannel discharge circuit is developed and validated by the experiment. With only 6-kV input voltage, 31-channels discharge is achieved. The breakdown voltage of each electrode gap is larger than 3 kV. The modified discharge circuit is certain to be widely used in the PSJA flow control field. (paper)

  7. Massive parallel optical pattern recognition and retrieval via a two-stage high-capacity multichannel holographic random access memory system

    International Nuclear Information System (INIS)

    Cai, Luzhong; Liu, Hua-Kuang

    2000-01-01

    The multistage holographic optical random access memory (HORAM) system reported recently by Liu et al. provides a new degree of freedom for improving storage capacity. We further present a theoretical and practical analysis of the HORAM system with experimental results. Our discussions include the system design and geometrical requirements, its applications for multichannel pattern recognition and associative memory, the 2-D and 3-D information storage capacity, and multichannel image storage and retrieval via VanderLugt correlator (VLC) filters and joint transform holograms. A series of experiments are performed to demonstrate the feasibility of the multichannel pattern recognition and image retrieval with both the VLC and joint transform correlator (JTC) architectures. The experimental results with as many as 2025 channels show good agreement with the theoretical analysis. (c) 2000 Society of Photo-Optical Instrumentation Engineers

  8. Discriminability of Single and Multichannel Intracortical Microstimulation within Somatosensory Cortex

    Directory of Open Access Journals (Sweden)

    Cynthia Kay Overstreet

    2016-12-01

    Full Text Available The addition of tactile and proprioceptive feedback to neuroprosthetic limbs is expected to significantly improve the control of these devices. Intracortical microstimulation (ICMS of somatosensory cortex is a promising method of delivering this sensory feedback. To date, the main focus of somatosensory ICMS studies has been to deliver discriminable signals, corresponding to varying intensity, to a single location in cortex. However, multiple independent and simultaneous streams of sensory information will need to be encoded by ICMS to provide functionally relevant feedback for a neuroprosthetic limb (e.g. encoding contact events and pressure on multiple digits.In this study, we evaluated the ability of an awake, behaving non-human primate (Macaca mulatta to discriminate ICMS stimuli delivered on multiple electrodes spaced within somatosensory cortex. We delivered serial stimulation on single electrodes to evaluate the discriminability of sensations corresponding to ICMS of distinct cortical locations. Additionally, we delivered trains of multichannel stimulation, derived from a tactile sensor, synchronously across multiple electrodes. Our results indicate that discrimination of multiple ICMS stimuli is a challenging task, but that discriminable sensory percepts can be elicited by both single and multichannel ICMS on electrodes spaced within somatosensory cortex.

  9. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. How to evaluate multichannel communication packages: a case study on mortgage information

    NARCIS (Netherlands)

    Herijgers, M.L.C.; Pander Maat, H.L.W.

    2015-01-01

    Complex decision-making is often supported not by single messages but by multichannel communication packages that need to be evaluated in their own right. The purpose of this paper is to present a new analytic approach to this package evaluation task combining textual analysis, functionalanalysis

  13. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  14. Range based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-08-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in Wireless Mesh Networks (WMNs). In this paper, researchers present a range based dynamic power control for MRMC WMNs. First, WMN is represented as a set of disjoint Unified...

  15. Multichannel electrogastrography under a magnifying glass--an in-depth study on reproducibility of fed state electrogastrograms.

    Science.gov (United States)

    Krusiec-Swidergoł, B; Jonderko, K

    2008-06-01

    We checked on reproducibility of parameters of a multichannel electrogastrogram in adults after intake of typical, applied in electrogastrography, test meals. Recordings of multichannel electrogastrograms were accomplished in four blocks comprising 18 subjects (nine healthy volunteers and nine patients with functional GI disorders) each. Every subject had two examinations taken 1-2 days apart, and a third one was accomplished at least 2 weeks before or after the two other sessions. The registration involved a 30-min fasted and a 2-h postprandial period after one of the meal stimuli tested within a given block: 400 mL water, 400 g yoghurt (378 kcal), a scrambled eggs sandwich (370 kcal), a pancake (355 kcal). From among the parameters reflecting the propagation of the gastric slow waves, the average percentage of slow wave coupling (APSWC) exhibited a good (coefficient of variation for paired examinations CV(p) < or = 10%) to moderate (10 < CV(p) < or = 30%) reproducibility. On the other hand, the reproducibility of the maximum dominant frequency difference and the spatial dominant power difference was found to be unsatisfactory. The reproducibility of the multichannel electrogastrographic parameters did not differ between healthy volunteers and patients with functional GI disorders. Gender or the kind of a test meal did not affect the reproducibility of the electrogastrographic parameters either. The medium-term reproducibility was not any worse than the short-term one. From among the parameters of a multichannel electrogastrogram intended to quantify the propagation of slow waves, only the APSWC offers a reproducibility potentially good enough for clinical applications.

  16. Altering user' acceptance of automation through prior automation exposure.

    Science.gov (United States)

    Bekier, Marek; Molesworth, Brett R C

    2017-06-01

    Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.

  17. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  18. Automated tuning of an eight-channel cardiac transceive array at 7 tesla using piezoelectric actuators.

    Science.gov (United States)

    Keith, Graeme A; Rodgers, Christopher T; Hess, Aaron T; Snyder, Carl J; Vaughan, J Thomas; Robson, Matthew D

    2015-06-01

    Ultra-high field (UHF) MR scanning in the body requires novel coil designs due to B1 field inhomogeneities. In the transverse electromagnetic field (TEM) design, maximum B1 transmit power can only be achieved if each individual transmit element is tuned and matched for different coil loads, which requires a considerable amount of valuable scanner time. An integrated system for autotuning a multichannel parallel transmit (pTx) cardiac TEM array was devised, using piezoelectric actuators, power monitoring equipment and control software. The reproducibility and performance of the system were tested and the power responses of the coil elements were profiled. An automated optimization method was devised and evaluated. The time required to tune an eight-element pTx cardiac RF array was reduced from a mean of 30 min to less than 10 min with the use of this system. Piezoelectric actuators are an attractive means of tuning RF coil arrays to yield more efficient B1 transmission into the subject. An automated mechanism for tuning these elements provides a practical solution for cardiac imaging at UHF, bringing this technology closer to clinical use. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  19. Automated MALDI Matrix Coating System for Multiple Tissue Samples for Imaging Mass Spectrometry

    Science.gov (United States)

    Mounfield, William P.; Garrett, Timothy J.

    2012-03-01

    Uniform matrix deposition on tissue samples for matrix-assisted laser desorption/ionization (MALDI) is key for reproducible analyte ion signals. Current methods often result in nonhomogenous matrix deposition, and take time and effort to produce acceptable ion signals. Here we describe a fully-automated method for matrix deposition using an enclosed spray chamber and spray nozzle for matrix solution delivery. A commercial air-atomizing spray nozzle was modified and combined with solenoid controlled valves and a Programmable Logic Controller (PLC) to control and deliver the matrix solution. A spray chamber was employed to contain the nozzle, sample, and atomized matrix solution stream, and to prevent any interference from outside conditions as well as allow complete control of the sample environment. A gravity cup was filled with MALDI matrix solutions, including DHB in chloroform/methanol (50:50) at concentrations up to 60 mg/mL. Various samples (including rat brain tissue sections) were prepared using two deposition methods (spray chamber, inkjet). A linear ion trap equipped with an intermediate-pressure MALDI source was used for analyses. Optical microscopic examination showed a uniform coating of matrix crystals across the sample. Overall, the mass spectral images gathered from tissues coated using the spray chamber system were of better quality and more reproducible than from tissue specimens prepared by the inkjet deposition method.

  20. Proceedings of workshop on streamer chamber

    International Nuclear Information System (INIS)

    Itoh, Hidihiko; Takahashi, Kaoru; Hirose, Tachishige; Masaike, Akira

    1978-08-01

    For high accuracy observation of multiple-body reactions, a vertex detector of high efficiency is essential. A bubble chamber, though excellent for tracks detection, is problematic in statistics accuracy. The vertex detector with a wire chamber, while better in this respect, difficult in multiple-particle detection etc. The workshop has had several meetings on a streamer chamber as a detector combining features of both bubble chamber and counter, with emphasis on tracks observation in avalanche mode and recordings not using films. Contents are on streamer chamber gas, analytical photography, data processing, simulation program, etc. (Mori, K.)

  1. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Muller, F; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The implementation of the signal generator is presented as well as an application where it was successfully utilized.

  2. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  3. Development of multichannel system for nuclear radiation spectrometry based on an embedded control and acquisition device Myrio-1900

    International Nuclear Information System (INIS)

    Hernandez D, S.

    2016-01-01

    This work describes the design a multichannel analyzer system 4096 channels (Mca) for gamma radiation spectrometry. The multichannel analyzer has as its main component an embedded company National Instruments model NI (Myrio-1900) module, which is integrated by a step of converting analog to digital signals (A / D) and digital-to-analog (D / A) a programmable gate array, and a processor real time (Rt). Through this module the pulses generated by the detector to be processed and subsequently forming the multichannel analyzer are acquired. In addition, a graphical user interface designed to make more use friendly system from a personal computer (Pc), embedded programming module and the user interface was done with the LabVIEW programming environment. tests with different sources of radiation ("6"0Co, "2"2"6Ra, "1"3"7Cs) and semiconductor detectors (Ge) and scintillation (Na) were made. Getting results satisfactory. (Author)

  4. Multiple multichannel spectra acquisition and processing system with intelligent interface

    International Nuclear Information System (INIS)

    Chen Ying; Wei Yixiang; Qu Jianshi; Zheng Futang; Xu Shengkui; Xie Yuanming; Qu Xing; Ji Weitong; Qiu Xuehua

    1986-01-01

    A Multiple multichannel spectra acquisition and processing system with intelligent interface is described. Sixteen spectra measured with various lengths, channel widths, back biases and acquisition times can be identified and collected by the intelligent interface simultaneously while the connected computer is doing data processing. The execution time for the Ge(Li) gamma-ray spectrum analysis software on IBM PC-XT is about 55 seconds

  5. Asymptotically exact solution of the multi-channel resonant-level model

    International Nuclear Information System (INIS)

    Zhang Guangming; Su Zhaobin; Yu Lu.

    1994-01-01

    An asymptotically exact partition function of the multi-channel resonant-level model is obtained through Tomonaga-Luttinger bosonization. A Fermi-liquid vs. non-Fermi-liquid transition, resulting from a competition between the Kondo and X-ray edge physics, is elucidated explicitly via the renormalization group theory. In the strong-coupling limit, the model is renormalized to the Toulouse limit. (author). 20 refs, 1 fig

  6. The software for the USB-based multi-channel analyzer system

    International Nuclear Information System (INIS)

    Zhou Tong; Wei Yixiang

    2002-01-01

    A new type of multi-channel analyzer system is introduced, which takes advantage of Universal Serial Bus to communicate with computer and gets the merit of fast speed, universality and Plug and Play. The authors discussed the framework of the system, primary functions, display of spectrum date and the way of communication with hardware. The environment of the program is Visual Basic 6.0

  7. A multichannel bioimpedance monitor for full-body blood flow monitoring

    Czech Academy of Sciences Publication Activity Database

    Vondra, Vlastimil; Jurák, Pavel; Viščor, Ivo; Halámek, Josef; Leinveber, P.; Matějková, M.; Soukup, L.

    2016-01-01

    Roč. 61, č. 1 (2016), s. 107-118 ISSN 0013-5585 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA ČR GAP102/12/2034 Institutional support: RVO:68081731 Keywords : bioimpedance * blood flow * cardiac output * multichannel measurement * non- invasive measurements * pulse wave velocity Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 0.915, year: 2016

  8. Multichannel perimetric alterations in systemic lupus erythematosus treated with hydroxychloroquine

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2017-04-01

    Some achromatic and color vision alterations may be present in SLE, especially when treated with hydroxychloroquine. The sensitivity losses detected in the chromatic channels in the central zone of the visual field were consistent with the results of the FM 100 Hue color test. Likewise, the multichannel perimetry detected sensitivity losses in the parafoveal area for both chromatic channels, especially for the blue-yellow.

  9. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  10. Optimization of multi-channel neutron focusing guides for extreme sample environments

    International Nuclear Information System (INIS)

    Di Julio, D D; Lelièvre-Berna, E; Andersen, K H; Bentley, P M; Courtois, P

    2014-01-01

    In this work, we present and discuss simulation results for the design of multichannel neutron focusing guides for extreme sample environments. A single focusing guide consists of any number of supermirror-coated curved outer channels surrounding a central channel. Furthermore, a guide is separated into two sections in order to allow for extension into a sample environment. The performance of a guide is evaluated through a Monte-Carlo ray tracing simulation which is further coupled to an optimization algorithm in order to find the best possible guide for a given situation. A number of population-based algorithms have been investigated for this purpose. These include particle-swarm optimization, artificial bee colony, and differential evolution. The performance of each algorithm and preliminary results of the design of a multi-channel neutron focusing guide using these methods are described. We found that a three-channel focusing guide offered the best performance, with a gain factor of 2.4 compared to no focusing guide, for the design scenario investigated in this work.

  11. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  12. An interactive visualization tool for multi-channel confocal microscopy data in neurobiology research

    KAUST Repository

    Yong Wan,

    2009-11-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist\\'s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system.

  13. Multichannel euv spectroscopy of high temperature plasmas

    International Nuclear Information System (INIS)

    Fonck, R.J.

    1983-11-01

    Spectroscopy of magnetically confined high temperature plasmas in the visible through x-ray spectral ranges deals primarily with the study of impurity line radiation or continuum radiation. Detailed knowledge of absolute intensities, temporal behavior, and spatial distributions of the emitted radiation is desired. As tokamak facilities become more complex, larger, and less accessible, there has been an increased emphasis on developing new instrumentation to provide such information in a minimum number of discharges. The availability of spatially-imaging detectors for use in the vacuum ultraviolet region (especially the intensified photodiode array) has generated the development of a variety of multichannel spectrometers for applications on tokamak facilities

  14. Arduino-based automation of a DNA extraction system.

    Science.gov (United States)

    Kim, Kyung-Won; Lee, Mi-So; Ryu, Mun-Ho; Kim, Jong-Won

    2015-01-01

    There have been many studies to detect infectious diseases with the molecular genetic method. This study presents an automation process for a DNA extraction system based on microfluidics and magnetic bead, which is part of a portable molecular genetic test system. This DNA extraction system consists of a cartridge with chambers, syringes, four linear stepper actuators, and a rotary stepper actuator. The actuators provide a sequence of steps in the DNA extraction process, such as transporting, mixing, and washing for the gene specimen, magnetic bead, and reagent solutions. The proposed automation system consists of a PC-based host application and an Arduino-based controller. The host application compiles a G code sequence file and interfaces with the controller to execute the compiled sequence. The controller executes stepper motor axis motion, time delay, and input-output manipulation. It drives the stepper motor with an open library, which provides a smooth linear acceleration profile. The controller also provides a homing sequence to establish the motor's reference position, and hard limit checking to prevent any over-travelling. The proposed system was implemented and its functionality was investigated, especially regarding positioning accuracy and velocity profile.

  15. Multi-channel electrical impedance tomography for regional tissue hydration monitoring

    International Nuclear Information System (INIS)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-01-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ∼35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in

  16. Multi-channel electrical impedance tomography for regional tissue hydration monitoring.

    Science.gov (United States)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-06-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical

  17. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  18. Technical features of the system used to perform multichannel urethral pressure profilometry

    NARCIS (Netherlands)

    Messelink, E. J.; Dobbe, I.; Kools, C.; Dabhoiwala, N. F.; Dijkhuizen, T.; Schneider, P.; Lettinga, K. P.; Kurth, K.

    1997-01-01

    Multichannel Urethral Pressure Profilometry (MCUPP) is a method used to get more information on the pressure distribution within the female urethra. This information may be of value in the diagnostic work up of women with urinary incontinence. Different systems are used for this technique. The pump

  19. Exploiting the opportunities of Internet and multi-channel pricing : An exploratory research

    NARCIS (Netherlands)

    Sotgiu, Francesca; Ancarani, Fabio

    2004-01-01

    Smart firms are not worried about the impact of the Internet on pricing, but realise that they have the unique opportunity to exploit new options and improve their marketing performance. Multi-channel pricing is one of the most interesting opportunities firms can exploit in the digital economy.

  20. Absorbed dose measurement by using tissue equivalent ionization chamber (pair ionization chamber) in the Yayoi reactor

    International Nuclear Information System (INIS)

    Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki

    1998-01-01

    Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)

  1. Development of secondary chamber for tar cracking-improvement of wood pyrolysis performance in pre-vacuum chamber

    Science.gov (United States)

    Siahaan, S.; Homma, H.; Homma, H.

    2018-02-01

    Energy crisis and global warming, in other words, climate change are critical topics discussed in various parts of the world. Global warming primarily result from too much emission of carbon dioxide (CO2) in the atmosphere. To mitigate global warming, or climate change and improve electrification in rural areas, wood pyrolysis technology is developed in a laboratory scale, of which gases are directly applicable to the gas engine generator. Our laboratory has developed a prototype of wood pyrolysis plant with a pre-vacuum chamber. However, tar yield was around 40 wt% of feedstock. This research aims to reduce tar yield by secondary tar cracking. For the secondary tar cracking, a secondary pre-vacuum chamber is installed after primary pre-vacuum chamber. Gases generated in the primary pre-vacuum chamber are lead into the secondary chamber that is heated up to 1000 K. This paper reports performance of the secondary chamber for secondary tar cracking in homogeneous mode and heterogeneous mode with char.

  2. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    International Nuclear Information System (INIS)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-01-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s −1 , the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay. (paper)

  3. Randomised multichannel singular spectrum analysis of the 20th century climate data

    Directory of Open Access Journals (Sweden)

    Teija Seitola

    2015-12-01

    Full Text Available In this article, we introduce a new algorithm called randomised multichannel singular spectrum analysis (RMSSA, which is a generalisation of the traditional multichannel singular spectrum analysis (MSSA into problems of arbitrarily large dimension. RMSSA consists of (1 a dimension reduction of the original data via random projections, (2 the standard MSSA step and (3 a recovery of the MSSA eigenmodes from the reduced space back to the original space. The RMSSA algorithm is presented in detail and additionally we show how to integrate it with a significance test based on a red noise null-hypothesis by Monte-Carlo simulation. Finally, RMSSA is applied to decompose the 20th century global monthly mean near-surface temperature variability into its low-frequency components. The decomposition of a reanalysis data set and two climate model simulations reveals, for instance, that the 2–6 yr variability centred in the Pacific Ocean is captured by all the data sets with some differences in statistical significance and spatial patterns.

  4. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    Science.gov (United States)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-05-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s-1, the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay.

  5. Schwinger variational principle in the nuclear two-body problem and multichannel theory

    International Nuclear Information System (INIS)

    Zubarev, A.L.; Podkopaev, A.P.

    1978-01-01

    The aim of the investigation is to study the Schwinger variational principle in the nuclear two-body problem and the multichannel theory. An approach is proposed to problems of the potential scattering based on the substitution of the exact potential operator V by the finite rank operator Vsup((n)) with which the dynamic equations are solved exactly. The functionals obtained for observed values coincide with corresponding expressions derived by the Schwinger variational principle with the set of test functions. The determination of the Schwinger variational principle is given. The method is given for finding amplitude of the double-particle scattering with the potential Vsup((n)). The corresponding amplitudes are constructed within the framework of the multichannel potential model. Interpolation formula for determining amplitude, which describes with high accuracy a process of elastic scattering for any energies, is obtained. On the basis of the above method high-energy amplitude may be obtained within the range of small and large scattering angles

  6. The impact of corn stover removal on N2O emission and soil respiration: An investigation with automated chambers

    Science.gov (United States)

    Corn stover removal, whether for silage, bedding, or bioenergy production, could have a variety of environmental consequences through its effect on soil processes, particularly N2O production and soil respiration. Because these effects may be episodic in nature, weekly snapshots with static chambers...

  7. Complacency and Automation Bias in the Use of Imperfect Automation.

    Science.gov (United States)

    Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L

    2015-08-01

    We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.

  8. Proportional chamber with data analog output

    International Nuclear Information System (INIS)

    Popov, V.E.; Prokof'ev, A.N.

    1977-01-01

    A proportional multiwier chamber is described. The chamber makes it possible to determine angles at wich a pion strikes a polarized target. A delay line, made of 60-core flat cable is used for removing signals from the chamber. From the delay line, signals are amplified and successively injected into shapers and a time-to-amplitude converter. An amplitude of the time-to amplitude converter output signal unambiguously determines the coordinate of a point at which a particle strikes the chamber plane. There are also given circuits of amplifiers, which consist of a preamplifier with gain 30 and a main amplifier with adjustable gain. Data on testing the chamber with the 450 MeV pion beam is demonstrated. The chamber features an efficiency of about 98 per cent under load of 2x10 5 s -1

  9. The Performance of Reflecting Multichannel Collimators as a Neutron Beam Filter and Polarizer

    DEFF Research Database (Denmark)

    Bjerrum Møller, Hans; Passell, L.; Stecher-Rasmussen, F.

    1963-01-01

    Summarizes the results obtained to date from a study of the properties of reflecting multi-channel collimators. The measurements have not yet been completed but enough information is available to give an indication of the capabilities of the system....

  10. Multichannel Seismic Reflection Data - SCAR - Antarctic Peninsula 1987-88, SDLS CD-ROM vol 24

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1987-88 in the Antarctic Peninsula, Antarctica, by the Japan National Oil...

  11. Multichannel Seismic Reflection Data - SCAR - Antarctic Peninsula - 1988-1989, SDLS CD-ROM vol 25

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1988-89 in the Antarctic Peninsula, Antarctica, by the Japan National Oil...

  12. Automated corrosion fatigue crack growth testing in pressurized water environments

    International Nuclear Information System (INIS)

    Ceschini, L.J.; Liaw, P.K.; Rudd, G.E.; Logsdon, W.A.

    1984-01-01

    This paper describes in detail a novel approach to construct a test facility for developing corrosion fatigue crack growth rate (FCGR) properties in aggressive environments. The environment studied is that of a pressurized water reactor (PWR) at 288 0 C (550 0 F) and 13.8 MPa (200 psig). To expedite data generation, each chamber was designed to accommodate two test specimens. A common water recirculation and pressurization system was employed to service two test chambers. Thus, four fatigue crack propagation rate tests could be conducted simultaneously in the pressurized water environment. The data analysis was automated to minimize the typically high labor costs associated with corrosion fatigue crack propagation testing. Verification FCGR tests conducted on an ASTM A469 rotor steel in a room temperature air environment as well as actual PWR environment FCGR tests performed on an ASTM A533 Grade B Class 2 pressure vessel steel demonstrated that the dual specimen test facility is an excellent system for developing the FCGR properties of materials in adverse environments

  13. On the relationship between multi-channel envelope and temporal fine structure

    DEFF Research Database (Denmark)

    Søndergaard, Peter Lempel; Decorsiere, Remi Julien Blaise; Dau, Torsten

    2011-01-01

    The envelope of a signal is broadly defined as the slow changes in time of the signal, where as the temporal fine structure (TFS) are the fast changes in time, i.e. the carrier wave(s) of the signal. The focus of this paper is on envelope and TFS in multi-channel systems. We discuss the differenc...

  14. An Improved Cloud Classification Algorithm for China’s FY-2C Multi-Channel Images Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Chun-Xiang Shi

    2009-07-01

    Full Text Available The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China’s first operational geostationary meteorological satellite FengYun-2C (FY-2C data. First, the capabilities of six widely-used Artificial Neural Network (ANN methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA and a Support Vector Machine (SVM, using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm imagery. The result shows that: (1 ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2 among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM and Probabilistic Neural Network (PNN. Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  15. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  16. Development of refined MCNPX-PARET multi-channel model for transient analysis in research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kalcheva, S.; Koonen, E. [SCK-CEN, BR2 Reactor Dept., Boeretang 200, 2400 Mol (Belgium); Olson, A. P. [RERTR Program, Nuclear Engineering Div., Argonne National Laboratory, Cass Avenue, Argonne, IL 60439 (United States)

    2012-07-01

    Reactivity insertion transients are often analyzed (RELAP, PARET) using a two-channel model, representing the hot assembly with specified power distribution and an average assembly representing the remainder of the core. For the analysis of protected by the reactor safety system transients and zero reactivity feedback coefficients this approximation proves to give adequate results. However, a more refined multi-channel model representing the various assemblies, coupled through the reactivity feedback effects to the whole reactor core is needed for the analysis of unprotected transients with excluded over power and period trips. In the present paper a detailed multi-channel PARET model has been developed which describes the reactor core in different clusters representing typical BR2 fuel assemblies. The distribution of power and reactivity feedback in each cluster of the reactor core is obtained from a best-estimate MCNPX calculation using the whole core geometry model of the BR2 reactor. The sensitivity of the reactor response to power, temperature and energy distributions is studied for protected and unprotected reactivity insertion transients, with zero and non-zero reactivity feedback coefficients. The detailed multi-channel model is compared vs. simplified fewer-channel models. The sensitivities of transient characteristics derived from the different models are tested on a few reactivity insertion transients with reactivity feedback from coolant temperature and density change. (authors)

  17. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  18. Data-Driven Visualization and Group Analysis of Multichannel EEG Coherence with Functional Units

    NARCIS (Netherlands)

    Caat, Michael ten; Maurits, Natasha M.; Roerdink, Jos B.T.M.

    2008-01-01

    A typical data- driven visualization of electroencephalography ( EEG) coherence is a graph layout, with vertices representing electrodes and edges representing significant coherences between electrode signals. A drawback of this layout is its visual clutter for multichannel EEG. To reduce clutter,

  19. The design of multi-channel pulse amplitude analyzer based on ARM micro controller

    International Nuclear Information System (INIS)

    Li Hai; Li Xiang; Liu Caixue

    2010-01-01

    It introduces the design of multi-channel pulse amplitude analyzer based on embedded ARM micro-controller. The embedded and real-time system μC/OS-II builds up the real-time and stability of the system and advances the integration. (authors)

  20. The multichannel system of synchronous photon counting of range 50 ns - 100 ms

    Energy Technology Data Exchange (ETDEWEB)

    Dmitriev, S M [and others

    1996-12-31

    A new type of the multichannel system of synchronous photon counting is designed. The recording past of the analyzer is described and the whole measurement process is considered. Frequency of the master generator is 75 MHz. 1 ref.; 2 figs.

  1. Multichannel customer segmentation : does the after-sales channel matter? : a replication and extension

    NARCIS (Netherlands)

    Keyser, A.; Schepers, J.J.L.; Konus, U.

    2015-01-01

    Segmentation is critical in developing a successful multichannel customer management strategy. Multiple researchers recognized the need to adopt a multi-stage customer journey perspective, taking into account the channels used for information search and product purchase. This paper aims to advance

  2. Multichannel Seismic Reflection Data - SCAR - Ross Sea 1987-1988, SDLS CD-ROM vol 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data from six lines recorded during 1988 in the Ross Sea, Antarctica, by the Bundesanstalt fur...

  3. Multichannel Seismic Reflection Data - SCAR - Prydz Bay - 1984-1985, SDLS CD-ROM vol 21

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1984-85 in the Prydz Bay region, Antarctica, by the Japan National Oil...

  4. Multichannel Seismic Reflection Data - SCAR - Amundsen Sea - 1986-1987, SDLS CD-ROM vol 23

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are stacked multichannel marine seismic reflection data recorded during 1986-87 in the Amundsen Sea, Antarctica, by the Japan National Oil Corporation....

  5. Analysis of flow distribution instability in parallel thin rectangular multi-channel system

    Energy Technology Data Exchange (ETDEWEB)

    Xia, G.L. [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China); Su, G.H., E-mail: ghsu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Peng, M.J. [Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China)

    2016-08-15

    Highlights: • Flow distribution instability in parallel thin rectangular multi-channel system is studied using RELAP5 codes. • Flow excursion may bring parallel heating channel into the density wave oscillations region. • Flow distribution instability is more likely to happen at low power/flow ratio conditions. • The increase of channel number will not affect the flow distribution instability boundary. • Asymmetry inlet throttling and heating will make system more unstable. - Abstract: The flow distribution instability in parallel thin rectangular multi-channel system has been researched in the present study. The research model of parallel channel system is established by using RELAP5/MOD3.4 codes. The transient process of flow distribution instability is studied at imposed inlet mass flow rate and imposed pressure drop conditions. The influence of heating power, mass flow rate, system pressure and channel number on flow distribution instability are analyzed. Furthermore, the flow distribution instability of parallel two-channel system under asymmetric inlet throttling and heating power is studied. The results show that, if multi-channel system operates at the negative slope region of channel ΔP–G curve, small disturbance in pressure drop will lead to flow redistribution between parallel channels. Flow excursion may bring the operating point of heating channel into the density-wave oscillations region, this will result in out-phase or in-phase flow oscillations. Flow distribution instability is more likely to happen at low power/flow ratio conditions, the stability of parallel channel system increases with system pressure, the channel number has a little effect on system stability, but the asymmetry inlet throttling or heating power will make the system more unstable.

  6. Process development for automated solar cell and module production. Task 4. Automated array assembly. Quarterly report No. 1

    Energy Technology Data Exchange (ETDEWEB)

    Hagerty, J. J.

    1980-10-15

    Work has been divided into five phases. The first phase is to modify existing hardware and controlling computer software to: (1) improve cell-to-cell placement accuracy, (2) improve the solder joint while reducing the amount of solder and flux smear on the cell's surface, and (3) reduce the system cycle time to 10 seconds. The second phase involves expanding the existing system's capabilities to be able to reject broken cells and make post-solder electrical tests. Phase 3 involves developing new hardware to allow for the automated encapsulation of solar modules. This involves three discrete pieces of hardware: (1) a vacuum platen end effector for the robot which allows it to pick up the 1' x 4' array of 35 inter-connected cells. With this, it can also pick up the cover glass and completed module, (2) a lamination preparation station which cuts the various encapsulation components from roll storage and positions them for encapsulation, and (3) an automated encapsulation chamber which interfaces with the above two and applies the heat and vacuum to cure the encapsulants. Phase 4 involves the final assembly of the encapsulated array into a framed, edge-sealed module completed for installation. For this we are using MBA's Glass Reinforced Concrete (GRC) in panels such as those developed by MBA for JPL under contract No. 955281. The GRC panel plays the multiple role of edge frame, substrate and mounting structure. An automated method of applying the edge seal will also be developed. The final phase (5) is the fabrication of six 1' x 4' electrically active solar modules using the above developed equipment. Progress is reported. (WHK)

  7. Pressure vessel rupture within a chamber: the pressure history on the chamber wall

    International Nuclear Information System (INIS)

    Baum, M.R.

    1989-04-01

    Generally there is a large number of pressure vessels containing high pressure gas on power stations and chemical plant. In many instances, particularly on power plant, these vessels are within the main building. If a pressure vessel were to fail, the surrounding structures would be exposed to blast loads and the forces resulting from jets of fluid issuing from the breached vessel. In the case where the vessel is in a relatively closed chamber there would also be a general overpressurisation of the chamber. At the design stage it is therefore essential to demonstrate that the plant could be safely shut down in the event of a pressure vessel failure, that is, it must be shown that the chamber will not collapse thus putting the building at risk or hazarding equipment essential for a safe shut down. Such an assessment requires the loads applied to the chamber walls, roof, etc. to be known. (author)

  8. Wet drift chambers for precise luminosity

    International Nuclear Information System (INIS)

    Anderson, B.E.; Kennedy, B.W.; Ahmet, K.; Attree, D.J.; Barraclough, G.A.; Cresswell, M.J.; Hayes, D.A.; Miller, D.J.; Selby, C.; Sherwood, P.

    1994-01-01

    A set of high-precision compact drift chambers has been a vital component of the OPAL luminosity monitor since the start of data-taking at LEP. They were augmented in 1992 by the addition of Small Angle Reference Chambers with a very similar design to the original chamber. The performance of the chambers is reviewed, highlighting both the importance of using polyalkylene glycol (Breox) to maintain a uniform and parallel electric field and the construction techniques used to sustain the required field strength. We describe some of the operating problems, with their solutions, and show how the chambers have been used in achieving a systematic error of 0.41% on the luminosity measurement. ((orig.))

  9. The Boycott effect in magma chambers

    Science.gov (United States)

    Blanchette, F.; Peacock, T.; Bush, J. W. M.

    2004-03-01

    We investigate the plausibility of the stratified Boycott effect as a source of layering in magma chambers. Crystal settling within the magma chamber will generate buoyant fluid near the sloping sidewalls whose vertical ascent may be limited by the ambient stratification associated with vertical gradients in SiO2. The resulting flow may be marked by a layered structure, each layer taking the form of a convection cell spanning the lateral extent of the magma chamber. Using parameters relevant to magma chambers, we estimate that such convection cells would be established over a timescale of a month and have a depth on the order of 4m, which is roughly consistent with field observations of strata within solidified chambers.

  10. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  11. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  12. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP.

  13. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Science.gov (United States)

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  14. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF

  15. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  16. Optimal spatiotemporal representation of multichannel EEG for recognition of brain states associated with distinct visual stimulus

    Science.gov (United States)

    Hramov, Alexander; Musatov, Vyacheslav Yu.; Runnova, Anastasija E.; Efremova, Tatiana Yu.; Koronovskii, Alexey A.; Pisarchik, Alexander N.

    2018-04-01

    In the paper we propose an approach based on artificial neural networks for recognition of different human brain states associated with distinct visual stimulus. Based on the developed numerical technique and the analysis of obtained experimental multichannel EEG data, we optimize the spatiotemporal representation of multichannel EEG to provide close to 97% accuracy in recognition of the EEG brain states during visual perception. Different interpretations of an ambiguous image produce different oscillatory patterns in the human EEG with similar features for every interpretation. Since these features are inherent to all subjects, a single artificial network can classify with high quality the associated brain states of other subjects.

  17. Nondestructive measurement of tomato postharvest quality using a multichannel hyperspectral imaging probe

    Science.gov (United States)

    A multichannel hyperspectral imaging probe with 30 optic fibers covering the wavelength range of 550-1,650 nm and the light source-detector distances of 1.5-36 mm was recently developed for optical property measurement and quality evaluation of food products with flat or curved surface. This paper r...

  18. Multiple-state based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-01-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in wireless mesh networks (WMNs). In this paper, we present asynchronous multiple-state based power control for MRMC WMNs. First, WMN is represented as a set of disjoint...

  19. Multichannel Image Mosaicing of Stem Cells

    OpenAIRE

    Alessandro Bevilacqua; Alessandro Gherardi; Filippo Piccinini

    2010-01-01

    Image mosaicing techniques are usually employed to offer researchers a wider field of view of microscopic image of biological samples. a mosaic is commonly achieved using automated microscopes and often with one “color" channel, whether it refers to natural or fluorescent analysis. In this work we present a method to achieve three subsequent mosaics of the same part of a stem cell culture analyzed in phase contrast and in fluorescence, with a common non-automated inverted microscope. The mosa...

  20. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.