WorldWideScience

Sample records for multi-slice computed tomography

  1. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  2. Multi-slice Computed Tomography Appearance of Abscess of Cavum Septum Pellucidum: A Case Report and Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Vasudev, M.K.; Chavan, R.G.; Nagarajan, K.; Shukla, D.; Devi, B.I. [National Inst. of Mental Health and Neurosciences, Bangalore (India). Depts. of Neuroimaging and Interventional Radiology and of Neurosurgery

    2006-04-15

    Abscesses involving the cavum septum pellucidum are rare and, owing to their location, detection may be difficult with routine conventional computed tomography (CT). Only a few isolated cases have been reported and mostly in children. We report a case of abscess involving the cavum septum pellucidum in an adult and its appearance on multi-slice spiral CT Abscess, cavum septum pellucidum, multi-slice CT, surgery.

  3. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    Science.gov (United States)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Muhammad, H.; Sabarudin, A.; Ang, W. C.; Bahruddin, N. A.

    2016-03-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDIw (mGy), CTDIvol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDIvol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors.

  4. Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia

    International Nuclear Information System (INIS)

    Karim, M K A; Hashim, S; Ang, W C; Bahruddin, N A; Bakar, K A; Muhammad, H; Sabarudin, A

    2016-01-01

    Radiation doses from computed tomography (CT) are the highest and most hazardous compared to other imaging modalities. This study aimed to evaluate radiation dose in Johor, Malaysia to patients during computed tomography examinations of the brain, chest and abdomen and to establish the local diagnostic reference levels (DRLs) as are present with the current, state- of-art, multi-slice CT scanners. Survey forms were sent to five centres performing CT to obtain data regarding acquisition parameters as well as the dose information from CT consoles. CT- EXPO (Version 2.3.1, Germany) was used to validate the dose information. The proposed DRLs were indicated by rounding the third quartiles of whole dose distributions where mean values of CTDI w (mGy), CTDI vol (mGy) and DLP (mGy.cm) were comparable with other reference levels; 63, 63, and 1015 respectively for CT Brain; 15, 14, and 450 respectively for CT thorax and 16, 17, and 590 respectively for CT abdomen. The study revealed that the CT practice and dose output were revolutionised, and must keep up with the pace of introductory technology. We suggest that CTDI vol should be included in current national DRLs, as modern CTs are configured with a higher number of detectors and are independent of pitch factors. (paper)

  5. Multi-slice computed tomography urography after diuretic injection in children with urinary tract dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Kosucu, P.; Ahmetoglu, A.; Imamoglu, M.; Cay, A.; Ozdemir, O.; Dinc, H.; Kosucu, M.; Sari, A.; Saruhan, H.; Gumele, H.R. [Farabi Hospital, Trabzon (Turkey). Dept. of Radiology

    2004-02-01

    To evaluate the potential use of multi-slice computed tomography urography (MSCTU) after diuretic injection in children with urinary tract dilatation. MSCTU was performed in 19 patients (11 boys, 8 girls, mean age 5.4 years) with suspicion of urinary tract obstruction and dilatation. Furosemide, 1 mg/kg, was injected 3 min before contrast material administration and followed by a bolus of 30 ml of physiologic saline solution immediately after application of contrast material. Excretory-phase images were obtained through the abdomen and pelvis beginning 10 min after initiation of the injection of contrast material. Maximum intensity projection (MIP) and volume rendering (VR) images were post-processed to obtain urographic views. MSCTU revealed pathology in 16 of 19 patients, while 3 patients had normal findings. Ureteropelvic obstruction was found in 4 patients, obstructive megaureter in 8. Both ureteropelvic obstruction and obstructive megaureter were disclosed in 1 patient, partial ureteral duplication in 1 patient, and both complete ureteral duplication and ureterocele in 2 patients. In all patients, MIP and VR images could satisfactorily show the pathologies of the urinary tract. The estimated effective average doses of MSCTU were higher than IVU. Preliminary results of furosemide-enhanced MSCTU demonstrated consistently dilated urinary tracts, obstruction levels, and underlying pathologies better than US and IVU.

  6. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    International Nuclear Information System (INIS)

    Liang Xin; Jacobs, Reinhilde; Hassan, Bassam; Li Limin; Pauwels, Ruben; Corpas, Livia; Souza, Paulo Couto; Martens, Wendy; Shahbazian, Maryam; Alonso, Arie

    2010-01-01

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  7. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xin, E-mail: Xin.Liang@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); College of Stomatology, Dalian Medical University (China); Jacobs, Reinhilde, E-mail: Reinhilde.Jacobs@uz.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Hassan, Bassam, E-mail: b.hassan@acta.n [Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam (Netherlands); Li Limin, E-mail: Limin.Li@uz.kuleuven.b [Department of Paediatric Dentistry and Special Dental Care, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Pauwels, Ruben, E-mail: Ruben.Pauwels@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Corpas, Livia, E-mail: LiviaCorpas@gmail.co [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Souza, Paulo Couto, E-mail: Paulo.CoutoSouza@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Martens, Wendy, E-mail: wendy.martens@uhasselt.b [Department of Basic Medical Sciences, Faculty of Medicine, University of Hasselt, Diepenbeek (Belgium); Shahbazian, Maryam, E-mail: Maryam.Shahbazian@student.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Alonso, Arie, E-mail: ariel.alonso@uhasselt.b [Department of Biostatistics and Statistical Bioinformatics, Universiteit Hasselt (Belgium)

    2010-08-15

    Aims: To compare image quality and visibility of anatomical structures in the mandible between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: One dry mandible was scanned with five CBCT scanners (Accuitomo 3D, i-CAT, NewTom 3G, Galileos, Scanora 3D) and one MSCT system (Somatom Sensation 16) using 13 different scan protocols. Visibility of 11 anatomical structures and overall image noise were compared between CBCT and MSCT. Five independent observers reviewed the CBCT and the MSCT images in the three orthographic planes (axial, sagittal and coronal) and assessed image quality on a five-point scale. Results: Significant differences were found in the visibility of the different anatomical structures and image noise level between MSCT and CBCT and among the five CBCT systems (p = 0.0001). Delicate structures such as trabecular bone and periodontal ligament were significantly less visible and more variable among the systems in comparison with other anatomical structures (p = 0.0001). Visibility of relatively large structures such as mandibular canal and mental foramen was satisfactory for all devices. The Accuitomo system was superior to MSCT and all other CBCT systems in depicting anatomical structures while MSCT was superior to all other CBCT systems in terms of reduced image noise. Conclusions: CBCT image quality is comparable or even superior to MSCT even though some variability exists among the different CBCT systems in depicting delicate structures. Considering the low radiation dose and high-resolution imaging, CBCT could be beneficial for dentomaxillofacial radiology.

  8. [Diagnostic significance of multi-slice computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Liu, Fang; Tian, Zhi-Liang; Lei, Zi-Qiao; Li, You-Lin; Kong, Wei-Jia

    2005-04-01

    To evaluate the feasibility and usability of multi-slice computed tomography (MSCT) in congenital inner ear malformations. Fourty-four patients with sensorineural hearing loss (SNHL) were examined by a Somatom Sensation 16 (siemens, Germany) CT scanner with following parameters: 120 kV, 100 mAs, 0.75 mm collimation, 1 mm reconstruction increment, a pitch factor of 1 and a field of view of 100 mm. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment, and a field of view of 50 mm. The 3D reconstructions were done with volume rendering technique (VRT) on the workstation (3D Virtuoso and Wizard,siemens). Twenty-five patients were normal and 19 patients (36 ears) were congenital inner ear malformations among 44 patients scanned with MSCT. Of the malformations, all the axial, MPR and VRT images can display the site and degree in 33 ears. VRT images were superior to the axial images in displaying the malformations in 3 ears with the small lateral semicircular canal malformations. The malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity, 5 ears), vestibular and semicircular canal malformations( 14 ears), vestibular aqueduct dilate( 16 ears, of which 6 ears accompanied by other malformations), the internal auditory canal malformation(8 ears, all accompanied by other malformations). MSCT allows a comprehensively assessing various congenital ear malformations through high quality MPR and VRT reconstructions. VRT images can display the site and degree of the malformations three-dimensionally and intuitionisticly. It is very useful to the cochlear implantation.

  9. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  10. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  11. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  12. Mid-term results of off-pump coronary artery bypass grafting assessed by multi-slice computed tomography

    International Nuclear Information System (INIS)

    Yoshida, Seijiro; Nitta, Yoshio; Oda, Katsuhiko

    2004-01-01

    Off-pump coronary artery bypass (OPCAB) has recently increased in popularity, but the long-term results are still unknown. We evaluated the mid-term results of OPCAB surgery using multi-slice computed tomography (MSCT), which is a non-invasive postoperative evaluation method. Thirty-one consecutive patients who underwent OPCAB surgery at least 2 years prior to the study were selected. The age was 50 to 79 years (66.9±6.5) and the ratio of men to women was 26:5. Coronary angiography was performed in all patients at 2 weeks postoperatively. The follow-up was complete, and mean follow-up was 30.9 months. There were no hospital deaths and 1 non-cardiac late death. The graft patency rate in coronary angiography was left internal thoracic artery (LITA) 30/30 (100%), right internal thoracic artery (RITA) 2/2 (100%), radial artery (RA) 14/15 (93%), saphenous vein graft (SVG) 15/17 (88%). No graft became occluded on MSCT study and all patients have been angina-free during the follow-up period. We suggest that OPCAB is feasible in most patients with good patency and low mortality. MSCT is an effective follow up method for the morphological findings and noninvasive quantitative evaluation of the bypass grafts. (author)

  13. A comparison of shielding calculation methods for multi-slice computed tomography (CT) systems

    International Nuclear Information System (INIS)

    Cole, J A; Platten, D J

    2008-01-01

    Currently in the UK, shielding calculations for computed tomography (CT) systems are based on the BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) working group publication from 2000. Concerns have been raised internationally regarding the accuracy of the dose plots on which this method depends and the effect that new scanner technologies may have. Additionally, more recent shielding methods have been proposed by the NCRP (National Council on Radiation Protection) from the USA. Thermoluminescent detectors (TLDs) were placed in three CT scanner rooms at different positions for several weeks before being processed. Patient workload and dose data (DLP: the dose length product and mAs: the tube current-time product) were collected for this period. Individual dose data were available for more than 95% of patients scanned and the remainder were estimated. The patient workload data were used to calculate expected scatter radiation for each TLD location by both the NCRP and BIR-IPEM methods. The results were then compared to the measured scattered radiation. Calculated scattered air kerma and the minimum required lead shielding were found to be frequently overestimated compared to the measured air kerma, on average almost five times the measured scattered air kerma.

  14. The development of remote teaching laboratory access software for multi-slice computed optical tomography for use in undergraduate nuclear education

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.J.; Nichita, E., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2013-07-01

    Internet-based laboratory exercises were developed for a course on biomedical imaging at the University of Ontario Institute of Technology. These exercises used a multi-slice computed optical tomography machine named DeskCAT to instruct students on the principals of computed tomography. User management software was developed which enabled course instructors to quickly set up a computer to accept a series of scheduled remote user connections for a classroom. Laboratory exercises using the DeskCAT machine were developed to be conducted remotely. (author)

  15. The development of remote teaching laboratory access software for multi-slice computed optical tomography for use in undergraduate nuclear education

    International Nuclear Information System (INIS)

    Price, T.J.; Nichita, E.

    2013-01-01

    Internet-based laboratory exercises were developed for a course on biomedical imaging at the University of Ontario Institute of Technology. These exercises used a multi-slice computed optical tomography machine named DeskCAT to instruct students on the principals of computed tomography. User management software was developed which enabled course instructors to quickly set up a computer to accept a series of scheduled remote user connections for a classroom. Laboratory exercises using the DeskCAT machine were developed to be conducted remotely. (author)

  16. Global and regional left ventricular function: a comparison between gated SPECT, 2D echocardiography and multi-slice computed tomography

    International Nuclear Information System (INIS)

    Henneman, Maureen M.; Bax, Jeroen J.; Holman, Eduard R.; Schuijf, Joanne D.; Jukema, J.W.; Wall, Ernst E. van der; Stokkel, Marcel P.M.; Lamb, Hildo J.; Roos, Albert de

    2006-01-01

    Global and regional left ventricular (LV) function are important indicators of the cardiac status in patients with coronary artery disease (CAD). Therapy and prognosis are to a large extent dependent on LV function. Multi-slice computed tomography (MSCT) has already earned its place as an imaging modality for non-invasive assessment of the coronary arteries, but since retrospective gating to the patient's ECG is performed, information on LV function can be derived. In 49 patients with known or suspected CAD, coronary angiography with MSCT imaging was performed, in addition to gated SPECT and 2D echocardiography. LV end-diastolic and LV end-systolic volumes and LV ejection fraction were analysed with dedicated software (CMR Analytical Software System, Medis, Leiden, The Netherlands for MSCT; gated SPECT by QGS, Cedars-Sinai Medical Center, Los Angeles, CA, USA), and by the biplane Simpson's rule for 2D echocardiography. Regional wall motion was evaluated according to a 17-segment model and a three-point score system. Correlations were fairly good between gated SPECT and MSCT (LVEDV: r=0.65; LVESV: r=0.63; LVEF: r=0.60), and excellent between 2D echocardiography and MSCT (LVEDV: r=0.92; LVESV: r=0.93; LVEF: r=0.80). Agreement for regional wall motion was 95% (κ=0.66) between gated SPECT and MSCT, and 96% (κ=0.73) between 2D echocardiography and MSCT. Global and regional LV function and LV volumes can be adequately assessed with MSCT. Correlations with 2D echocardiography are stronger than with gated SPECT. (orig.)

  17. Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography.

    Science.gov (United States)

    Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F

    2012-06-01

    Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.

  18. Preliminary feasibility assessment on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Zhang Chenshi; Tao Zhiwei

    2003-01-01

    Objective: To evaluate the feasibility on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography (MSCT) . Methods: 27 patients with bronchogenic adenocarcinomas (diameter ≤4 cm) underwent multi-location dynamic contrast material-enhanced (90 ml, 4 ml/s) serial CT. These dynamic images were processed with the 'time lapse' software and the 'functional CT' software. Peak heights of bronchogenic adenocarcinoma and the aorta, perfusion and mean transit time (MTT) were measured. Ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta was calculated. Perfusion and mean transit time images were obtained. Results: Peak height of bronchogenic adenocarcinoma was (36.66 ± 13.53) HU. No statistically significant difference in the peak height was found between our results and the results of Ukihide et al (mean peak height 34.1 HU) (t =0.981, P = 0.335). Bronchogenic adenocarcinoma-to-aorta ratio was (15.72±4.66 )%. The difference in bronchogenic adenocarcinoma -to-aorta ratio between our results and the results of Zhang and Kono (mean malignant SPN-to-aorta ratio 14.6%) did not reach statistical significance (t=1.244, P=0.225). The mean perfusion value (3.278 ml·min - · kg -1 ) was in the range of that (1.36-2.98 ml·min -1 ·kg -1 ) measured with a single photon emission CT (SPECT). Mean transit time was (17.60 ± 4.52) s. Conclusion: It is feasible to investigate bronchogenic adenocarcinoma angiogenesis with dynamic MSCT

  19. Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment.

    Science.gov (United States)

    Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C

    2014-01-01

    Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.

  20. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  1. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun

    2013-12-01

    Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.

  2. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data

    Energy Technology Data Exchange (ETDEWEB)

    Klintstroem, Eva; Smedby, Oerjan [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); UHL County Council of Oestergoetland, Department of Radiology, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Moreno, Rodrigo [Linkoeping University, Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences (IMH)/Radiology, Linkoeping (Sweden); Brismar, Torkel B. [KUS Huddinge, Department of Clinical Science, Intervention and Technology at Karolinska Institutet and Department of Radiology, Stockholm (Sweden)

    2014-02-15

    Bone strength depends on both mineral content and bone structure. The aim of this in vitro study was to develop a method of quantitatively assessing trabecular bone structure by applying three-dimensional image processing to data acquired with multi-slice and cone-beam computed tomography using micro-computed tomography as a reference. Fifteen bone samples from the radius were examined. After segmentation, quantitative measures of bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular nodes, and trabecular termini were obtained. The clinical machines overestimated bone volume and trabecular thickness and underestimated trabecular nodes and number, but cone-beam CT to a lesser extent. Parameters obtained from cone beam CT were strongly correlated with μCT, with correlation coefficients between 0.93 and 0.98 for all parameters except trabecular termini. The high correlation between cone-beam CT and micro-CT suggest the possibility of quantifying and monitoring changes of trabecular bone microarchitecture in vivo using cone beam CT. (orig.)

  3. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  4. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    International Nuclear Information System (INIS)

    Liang Xin; Lambrichts, Ivo; Sun Yi; Denis, Kathleen; Hassan, Bassam; Li Limin; Pauwels, Ruben; Jacobs, Reinhilde

    2010-01-01

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm. Results: The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively. Conclusion: The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.

  5. A comparative study of accuracy of linear measurements using cone beam and multi-slice computed tomographies for evaluation of mandibular canal location in dry mandibles.

    Science.gov (United States)

    Naser, Asieh Zamani; Mehr, Bahar Behdad

    2013-01-01

    Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specific distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images. Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coefficient (ICC). There was a significant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT. The results of this study showed that there is significant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically significant.

  6. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Lei Zhen, E-mail: leizhen2004@163.com [Department of Anatomy, Chinese Medical University, No. 92, Beiermalu Road, Heping District, Shenyang, 110001 (China) and Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Ma Heji, E-mail: maheji9831@sina.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xu Na, E-mail: xuna821230@sohu.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xi Huanjiu, E-mail: xihuanjiu2004@yahoo.cn [Anthropology Institute, Liaoning Medical College, No. 40, Sanduan, Songpo Rd, Jinzhou, 121001 (China)

    2011-05-15

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  7. Genetic association of glutathione peroxidase-1 with coronary artery calcification in type 2 diabetes: a case control study with multi-slice computed tomography

    Directory of Open Access Journals (Sweden)

    Fujimoto Kei

    2007-09-01

    Full Text Available Abstract Background Although oxidative stress by accumulation of reactive oxygen species (ROS in diabetes has become evident, it remains unclear what genes, involved in redox balance, would determine susceptibility for development of atherosclerosis in diabetes. This study evaluated the effect of genetic polymorphism of enzymes producing or responsible for reducing ROS on coronary artery calcification in type 2 diabetes (T2D. Methods An index for coronary-arteriosclerosis, coronary artery calcium score (CACS was evaluated in 91 T2D patients using a multi-slice computed tomography. Patients were genotyped for ROS-scavenging enzymes, Glutathione peroxidase-1 (GPx-1, Catalase, Mn-SOD, Cu/Zn-SOD, as well as SNPs of NADPH oxidase as ROS-promoting elements, genes related to onset of T2D (CAPN10, ADRB3, PPAR gamma, FATP4. Age, blood pressure, BMI, HbA1c, lipid and duration of diabetes were evaluated for a multivariate regression analysis. Results CACS with Pro/Leu genotype of the GPx-1 gene was significantly higher than in those with Pro/Pro (744 ± 1,291 vs. 245 ± 399, respectively, p = 0.006. In addition, genotype frequency of Pro/Leu in those with CACS ≥ 1000 was significantly higher than in those with CACS OR = 3.61, CI = 0.97–13.42; p = 0.045 when tested for deviation from Hardy-Weinberg's equilibrium. Multivariate regression analyses revealed that CACS significantly correlated with GPx-1 genotypes and age. Conclusion The presence of Pro197Leu substitution of the GPx-1 gene may play a crucial role in determining genetic susceptibility to coronary-arteriosclerosis in T2D. The mechanism may be associated with a decreased ability to scavenge ROS with the variant GPx-1.

  8. Left atrial accessory appendages, diverticula, and left-sided septal pouch in multi-slice computed tomography. Association with atrial fibrillation and cerebrovascular accidents.

    Science.gov (United States)

    Hołda, Mateusz K; Koziej, Mateusz; Wszołek, Karolina; Pawlik, Wiesław; Krawczyk-Ożóg, Agata; Sorysz, Danuta; Łoboda, Piotr; Kuźma, Katarzyna; Kuniewicz, Marcin; Lelakowski, Jacek; Dudek, Dariusz; Klimek-Piotrowska, Wiesława

    2017-10-01

    The aim of this study is to provide a morphometric description of the left-sided septal pouch (LSSP), left atrial accessory appendages, and diverticula using cardiac multi-slice computed tomography (MSCT) and to compare results between patient subgroups. Two hundred and ninety four patients (42.9% females) with a mean of 69.4±13.1years of age were investigated using MSCT. The presence of the LSSP, left atrial accessory appendages, and diverticula was evaluated. Multiple logistic regression analysis was performed to check whether the presence of additional left atrial structures is associated with increased risk of atrial fibrillation and cerebrovascular accidents. At least one additional left atrial structure was present in 51.7% of patients. A single LSSP, left atrial diverticulum, and accessory appendage were present in 35.7%, 16.0%, and 4.1% of patients, respectively. After adjusting for other risk factors via multiple logistic regression, patients with LSSP are more likely to have atrial fibrillation (OR=2.00, 95% CI=1.14-3.48, p=0.01). The presence of a LSSP was found to be associated with an increased risk of transient ischemic attack using multiple logistic regression analysis after adjustment for other risk factors (OR=3.88, 95% CI=1.10-13.69, p=0.03). In conclusion LSSPs, accessory appendages, and diverticula are highly prevalent anatomic structures within the left atrium, which could be easily identified by MSCT. The presence of LSSP is associated with increased risk for atrial fibrillation and transient ischemic attack. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    International Nuclear Information System (INIS)

    Lei Zhen; Ma Heji; Xu Na; Xi Huanjiu

    2011-01-01

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  10. Acute and chronic myocardial infarction in a pig model: Utility of multi-slice cardiac computed tomography in assessing myocardial viability and infarct parameters

    International Nuclear Information System (INIS)

    Qu Xinkai; Fang Weiyi; Ye Jianding; Koh, Angela S.; Xu Yingjia; Guan Shaofeng; Li Ruogu; Shen Yan

    2012-01-01

    Objectives: The aim of this study was to determine the feasibility of multi-slice computed tomography (MSCT) biphasic imaging in assessing myocardial viability and infarct parameters in both acutely and chronically infarcted pig models. Materials and methods: Seven pigs underwent ligation of the distal left anterior descending artery. Imaging was performed on the day of infarction and 3 months post-infarct, with contrast infusion followed by MSCT scan acquisition at different time-points. Left ventricular ejection fractions (LVEFs) were obtained by left ventriculography (LVG) after 3 months. Infarcted locations found using MSCT were compared with those obtained using SPECT. Infarcted areas were also analysed histopathologically and compared with the findings from MSCT. Results: Chronic phase images had perfusion defects with lower CT values relative to normal myocardium (43 ± 10 HU vs. 156 ± 13 HU, p = 0.001) on the early images but no residual defects on delayed images. However, we found hyperenhancing regions on delayed images (244 ± 20 HU vs. 121 ± 25 HU, p = 0.001), and good correlation between MSCT- and LVG-derived LVEFs (60.56 ± 7.56%). The areas identified by MSCT corresponded to the location of 201 Tl SPECT-/pathologic staining-derived regions in all models. Infarct size was in good agreement with MSCT and pathological analyses of chronic phase models. Conclusions: Necrotic myocardium in different stages after infarction could be qualitatively and quantitatively assessed using MSCT biphasic imaging, as could the status of microcirculation formation. MSCT-measured LVEFs matched well with other modalities, and hence MSCT is a useful tool in assessing post-infarct cardiac function.

  11. Evaluation of the accuracy of linear measurements on multi-slice and cone beam computed tomography scans to detect the mandibular canal during bilateral sagittal split osteotomy of the mandible.

    Science.gov (United States)

    Freire-Maia, B; Machado, V deC; Valerio, C S; Custódio, A L N; Manzi, F R; Junqueira, J L C

    2017-03-01

    The aim of this study was to compare the accuracy of linear measurements of the distance between the mandibular cortical bone and the mandibular canal using 64-detector multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT). It was sought to evaluate the reliability of these examinations in detecting the mandibular canal for use in bilateral sagittal split osteotomy (BSSO) planning. Eight dry human mandibles were studied. Three sites, corresponding to the lingula, the angle, and the body of the mandible, were selected. After the CT scans had been obtained, the mandibles were sectioned and the bone segments measured to obtain the actual measurements. On analysis, no statistically significant difference was found between the measurements obtained through MSCT and CBCT, or when comparing the measurements from these scans with the actual measurements. It is concluded that the images obtained by CT scan, both 64-detector multi-slice and cone beam, can be used to obtain accurate linear measurements to locate the mandibular canal for preoperative planning of BSSO. The ability to correctly locate the mandibular canal during BSSO will reduce the occurrence of neurosensory disturbances in the postoperative period. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Study of CdTe:Cl and CdZnTe detectors for medical multi-slices X-ray Computed Tomography

    International Nuclear Information System (INIS)

    Ricq, St.

    1999-01-01

    The application of CdTe and CdZnTe detectors to medical X-ray Computed Tomography have been investigated. Different electrodes (Au, Pt, In) have been deposited on CdZnTe HPBM and on CdTe:ClTHM. Their injection properties have been determined with Current-Voltage characteristics. Under X-ray in CT conditions, injection currents measurements reveal trapped carriers space-charges formation. The same way, the comparisons of the responses to X-beam cut-off with various injection possibilities enable to follow the space-charges evolutions and then to determine the predominant traps types. Nevertheless, both hole and electron traps are responsible for the memory effect e.g. the currents levels dependence with irradiation history. This effect is noticed in particular on responses to fast flux variations that simulate scanner's conditions. Trap levels probably corresponding to native defects are responsible for these limitations. In order to make such detectors suitable for X-ray Computed Tomography, significant progresses in CdTe for CdZnTe crystal growth with an important defects densities reduction (factor 10), or possibly counting mode operation, seem necessary. (author)

  14. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability.

    Science.gov (United States)

    Arisan, Volkan; Karabuda, Zihni Cüneyt; Avsever, Hakan; Özdemir, Tayfun

    2013-12-01

    The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study. Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA). Radiographic and subjective bone quality classification (BQC) was also classified. Results were analyzed by correlation tests and multiple regressions (p < .05). CBCT-based gray density values (765 ± 97.32 voxel value) outside the implants were significantly higher than those of CT-based values (668.4 ± 110 Hounsfield unit, p < .001). Significant relations were found among the gray density values outside the implants, ITV (adjusted r(2)  = 0.6142, p = .001 and adjusted r(2)  = 0.5166, p = .0021), and RFA (adjusted r(2)  = 0.5642, p = .0017 and adjusted r(2)  = 0.5423, p = .0031 for CT and CBCT groups, respectively). Data from radiographic and subjective BQC were also in agreement. Similar to the gray density values of CT, that of CBCT could also be predictive for the subjective BQC and primary implant stability. Results should be confirmed on different CBCT scanners. © 2012 Wiley Periodicals, Inc.

  15. A study on optimal scan conditions of big bore multi-slice computed tomography based on radiation dose and image noise

    International Nuclear Information System (INIS)

    Lee, J. S.; Ye, S. J.; Kim, E. H.

    2011-01-01

    The newly introduced Big Bore computed tomography (CT) has a possibility to increase the tube current product scan time (mA s) for compensation of image degradation due to larger gentry opening without sound guideline. The objective of this paper is to derive optimal scan conditions for Big Bore CT scanner, mainly relating to the dose of diagnostic CT. The weighted CT dose index (CTDI w ) was estimated at five typical protocols, such as head and neck, brain, paediatric, chest and abdomen. Noises were analysed in a circle of 1 or 2 cm of diameter in CT image slice. The results showed that measured CTDI w values generally follow the theoretical rule at all scanning conditions of every protocol. Although image noises decrease with increment of mA s, analysed image noises do follow the theoretical rule, but only in specific protocols. This phenomenon is presumed to result from the photon energy spectra arriving at the detection system of the Big Bore scanner. (authors)

  16. Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography

    International Nuclear Information System (INIS)

    Theocharopoulos, Nicholas; Damilakis, John; Perisinakis, Kostas; Gourtsoyiannis, Nicholas

    2007-01-01

    In the present study effective dose values normalized to computed tomography dose index measured free in air were calculated for adult, newborn, 1, 5, 10 and 15 year old patients regarding scans of the head, chest, abdomen, pelvis, abdomen and pelvis, and trunk, using the energy imparted method. The effect of z overscanning on patient doses was accounted for, and normalized doses are provided for varying beam collimation, pitch and reconstruction slice width values. The contribution of overscanning depends on patient age, anatomic region imaged, acquisition and reconstruction settings. For a head scan it constitutes 15% of the adult effective dose and 24% of the effective dose to a newborn but for an abdomen scan it may be as high as 58% for a newborn and 31% for an adult. The ratios of normalized pediatric doses relative to that for adults for helical scans depend not only on age but also on acquisition and reconstruction parameters, because of variations in the relative distance between the primary beam and the radiosensitive tissues/organs of the body. Regarding scans of the trunk, pediatric doses are up to a factor of 2.5 times higher compared to adult doses (abdominal scans), whereas for scans of the head up to a factor of 1.5. Increasing the pitch value of helical scans while maintaining the same effective mAs setting, and hence noise levels, leads to an increase in patient doses which depends on age, body region, scan and reconstruction parameters. The % difference between doses at pitch 1.5 and pitch 1 is more pronounced in the abdominal region (14% increase for adults) and in young patients (31% in a newborn and 18% in a 10 year old patient) and it is minimal in head scans (4% increase in newborns and 1% in adults). If multiple body regions are to be imaged, doses to adults can be reduced by up to 15% and 36% to children by performing single long-range scans. Scanning adult patients at 100 kVp instead of 120 kVp, results in a 32% reduction in effective

  17. Impact of electrocardiogram-gated multi-slice computed tomography-based aortic annular measurement in the evaluation of paravalvular leakage following transcatheter aortic valve replacement: the efficacy of the OverSized AortiC Annular ratio (OSACA ratio) in TAVR.

    Science.gov (United States)

    Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki

    2013-07-01

    Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.

  18. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  19. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  20. Study of CdTe:Cl and CdZnTe detectors for medical multi-slices X-ray Computed Tomography; Etude de detecteurs en CdTe:Cl et CdZnTe pour la tomographie X medicale multicoupes

    Energy Technology Data Exchange (ETDEWEB)

    Ricq, St

    1999-09-28

    The application of CdTe and CdZnTe detectors to medical X-ray Computed Tomography have been investigated. Different electrodes (Au, Pt, In) have been deposited on CdZnTe HPBM and on CdTe:ClTHM. Their injection properties have been determined with Current-Voltage characteristics. Under X-ray in CT conditions, injection currents measurements reveal trapped carriers space-charges formation. The same way, the comparisons of the responses to X-beam cut-off with various injection possibilities enable to follow the space-charges evolutions and then to determine the predominant traps types. Nevertheless, both hole and electron traps are responsible for the memory effect e.g. the currents levels dependence with irradiation history. This effect is noticed in particular on responses to fast flux variations that simulate scanner's conditions. Trap levels probably corresponding to native defects are responsible for these limitations. In order to make such detectors suitable for X-ray Computed Tomography, significant progresses in CdTe for CdZnTe crystal growth with an important defects densities reduction (factor 10), or possibly counting mode operation, seem necessary. (author)

  1. Study of CdTe:Cl and CdZnTe detectors for medical multi-slices X-ray Computed Tomography; Etude de detecteurs en CdTe:Cl et CdZnTe pour la tomographie X medicale multicoupes

    Energy Technology Data Exchange (ETDEWEB)

    Ricq, St

    1999-09-28

    The application of CdTe and CdZnTe detectors to medical X-ray Computed Tomography have been investigated. Different electrodes (Au, Pt, In) have been deposited on CdZnTe HPBM and on CdTe:ClTHM. Their injection properties have been determined with Current-Voltage characteristics. Under X-ray in CT conditions, injection currents measurements reveal trapped carriers space-charges formation. The same way, the comparisons of the responses to X-beam cut-off with various injection possibilities enable to follow the space-charges evolutions and then to determine the predominant traps types. Nevertheless, both hole and electron traps are responsible for the memory effect e.g. the currents levels dependence with irradiation history. This effect is noticed in particular on responses to fast flux variations that simulate scanner's conditions. Trap levels probably corresponding to native defects are responsible for these limitations. In order to make such detectors suitable for X-ray Computed Tomography, significant progresses in CdTe for CdZnTe crystal growth with an important defects densities reduction (factor 10), or possibly counting mode operation, seem necessary. (author)

  2. Detection and severity of coronary disease: comparison between Framingham and calcium scores using multi-slice tomography

    International Nuclear Information System (INIS)

    Rodriguez Gomez, Maria Liliana; Montenegro, Edison; Ruiz, Angela Maria; Ardila, Jaime

    2011-01-01

    Introduction: multiple studies have shown that the coronary calcium index is an independent, more accurate predictor of future coronary events in relation to traditional risk factors. However, these studies have not been conducted in populations of developing countries like Colombia. Objective: to compare the strength of association between the Framingham index and the coronary calcium score in detecting the presence and severity of coronary disease as defined by 64-channel multi-slice angio-CT in order to provide additional information for decision-making in our asymptomatic coronary population. Methodology: we reviewed the written reports of coronary angiography scans performed in past 3 years. Based on this information, bivariate (calculation of Spearman rho correlation coefficients) and multivariate (logistic regression) analyses were performed. Results: the coronary calcium score showed a higher correlation with the presence and severity of coronary disease, Spearman Rho coefficient, compared with the Framingham index, Spearman's Rho coefficient of 0.30 (p<0.001). The moderate Framingham index (10-19%) shows no strength of association with significant and non-significant coronary artery disease, OR = 2, 51 CI 95% (0.7-8.9) and OR = 2.3 CI 95% (0.86-6.15), respectively. Patients with calcium values = 100 showed significant strength of association, OR = 182, 95% (17.4 -190.2), with significant coronary disease compared with high Framingham index values (=20%), OR = 18.6, CI 95% (1.75-198). Conclusions: the coronary calcium score has a higher correlation with the presence and severity of coronary disease when compared with the Framingham index. There is a low correlation between the index and Framingham coronary calcium.

  3. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  4. Review: Pre- and postinterventional control of stent grafts by means of single and multislice spiral computerized tomography

    International Nuclear Information System (INIS)

    Gebauer, B.; Knollmann, F.; Steinkamp, H.; Felix, R.

    2003-01-01

    Purpose. Could contrast enhanced computed tomography replace conventional catheter angiography in the preoperative evaluation of aortic aneurysms before stentgraft implantation? Does multi slice computed tomography have advantages comparing to single slice computed tomography? Methods. We compared 15 single slice with 13 multi slice computed tomography studies and reconstructions according to their ability to replace conventional catheter angiography in the preoperative evaluation. In the postoperative follow-up 60 single slice computed tomography studies were compared to 60 multi slice studies. Results. By using appropriate reconstructions the spiral computed tomography studies could deliver all information necessary for implantation. In our study no advantage of multi slice computed tomography could be detected. In the postoperative evaluation of stengrafts our computed tomography scan protocol could detect all relevant complications in single and multi slice computed tomography. No significant advantage of multi slice computed tomography could be detected. Conclusion. Contrast enhanced computed tomography is equal to conventional catheter angiography in the pre- and postoperative evaluation of stentgrafts. No significant advantage of multi slice versus single slice could be detected. (orig.) [de

  5. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  6. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  8. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  9. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  10. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  12. Measurement of multi-slice computed tomography dose profile with the Dose Magnifying Glass and the MOSkin radiation dosimeter

    International Nuclear Information System (INIS)

    Lian, C.P.L.; Wong, J.H.D.; Young, A.; Cutajar, D.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2013-01-01

    This study describes the application of two in-house developed dosimeters, the Dose Magnifying Glass (DMG) and the MOSkin dosimeter at the Centre for Medical Radiation Physics, University of Wollongong, Australia, for the measurement of CT dose profiles for a clinical diagnostic 16-slice MSCT scanner. Two scanner modes were used; axial mode and helical mode, and the effect of varying beam collimation and pitch was studied. With an increase in beam collimation in axial mode and an increase of CT pitch in helical mode, cumulative point dose at scanner isocentre decreased while FWHM increased. There was generally good agreement to within 3% between the acquired dose profiles obtained by the DMG and the film except at dose profile tails, where film over-responded by up to 30% due to its intrinsic depth dose dependence at low doses. -- Highlights: ► This study shows the CT beam profiles acquired with our institution's detectors. ► The DMG is a relative dosimeter calibrated to absolute MOSkin readings. ► There was good agreement between dose profiles acquired by the DMG and the film

  13. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  17. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  20. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  1. Application of the FDK algorithm for multi-slice tomographic image reconstruction; Aplicacao do algoritmo FDK para a reconstrucao de imagens tomograficas multicortes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto, E-mail: pcosta@if.usp.b [Universidade de Sao Paulo (IFUSP), SP (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear; Araujo, Ericky Caldas de Almeida [Fine Image Technology, Sao Paulo, SP (Brazil)

    2010-08-15

    This work consisted on the study and application of the FDK (Feldkamp- Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an X-ray equipment and a digital image detector charge-coupled device type were used. The FDK algorithm was implemented on a computer with a Pentium{sup R} XEON{sup TM} 3.0 processor, which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution ({mu}(r)) was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose distribution {mu}(r) was unknown. Some aspects of the reconstructed images were analyzed to assess the robustness and reproducibility of the system. During the system calibration, a linear relationship between CT number and linear attenuation coefficients of materials was verified, which validate the application of the implemented multi-slice tomographic system for the characterization of linear attenuation coefficients of distinct several objects. (author)

  2. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  3. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  4. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  6. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  9. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  10. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    Michalak, Maciej; Żurada, Anna; Biernacki, Maciej; Zygmunt, Kozielec

    2010-01-01

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8 th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  4. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  5. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  6. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  9. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  10. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  13. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  14. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  15. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  16. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  17. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  18. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  19. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  20. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  1. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  2. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  3. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  4. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  5. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  6. Evaluation of changes in the parameters of brain tissue perfusion in multi-slice computed tomography in patients after carotid artery stenting

    NARCIS (Netherlands)

    Szarmach, Arkadiusz; Halena, Grzegorz; Buczny, Jacek; Studniarek, Michał; Markiet, Karolina; Szurowska, Edyta; Retkowski, Mariusz; Piskunowicz, Maciej

    BACKGROUND: CT perfusion of the brain allows functional evaluation of cerebral blood flow. Patients with chronic internal carotid artery (ICA) stenosis may suffer from malperfusion. Improvement of cerebral blood flow and remission of neurological symptoms indicate the effectiveness of treatment of

  7. Sex determination using anthropometric measurements from multi-slice computed tomography of the 12th thoracic and the first lumbar vertebrae among adult Egyptians

    Directory of Open Access Journals (Sweden)

    Fatma M.M. Badr El Dine

    2015-09-01

    Conclusion: Finally, it was concluded that the 12th thoracic vertebra is more accurate for sex determination than the first lumbar vertebra in the Egyptian population, which means that bone dimensions are population specific.

  8. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  9. Approximations of noise covariance in multi-slice helical CT scans: impact on lung nodule size estimation.

    Science.gov (United States)

    Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J

    2011-10-07

    Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.

  10. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  11. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  12. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  13. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  14. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  15. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  16. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  17. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  18. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  19. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  20. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  2. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  8. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ... ray beam follows a spiral path. A special computer program processes this large volume of data to ...

  14. Computed tomography of the vesicular glands: anatomical animal model (Oryctolagus cuniculus)

    International Nuclear Information System (INIS)

    Dimitrov, R.; Stamatova-Yovcheva, K.; Hamza, S.; Toneva, Y.

    2014-01-01

    Spiral CT is a non-invasive imaging method of choice for animal anatomical studies. The aim of the study was to establish the imaging anatomical features of the vesicular glands in the rabbit. Eight sexually mature healthy clinically male New Zealand rabbits of 18 months of age with body weight from 2.8 kg to 3.2 kg were used. The animals were anesthetized. As contrast medium Opti-ray350 was administrated. The computed tomography scan was complied with certain bone and soft tissue markers. For this purpose, a whole body multi-slice spiral computed tomography scanner was used. The both soft tissue glands were heterogeneous and relatively hyperdense structures, and defined in detail from the adjacent soft tissues. The urinary bladder neck was ventrally to the glands. Both vesicular glands were better differentiated each other when the rabbit is examined in abdominal recumbence. In dorsal recumbence the shape of the transversal image of the glandular finding was oval. In abdominal recumbence both the left and right soft tissue vesicular gland were defined. Transversal anatomical computed tomographic investigation of the rabbit vesicular gland is a detailed and definitive method, to study the normal morphology of these glands. Key words: Vesicular Gland. Helical Computed Tomography. Anatomy. Rabbit

  15. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  16. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  17. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... diagnose sinusitis . evaluate sinuses that are filled with fluid or thickened sinus membranes . detect the presence of ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. If ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... to you, revolve around you during the imaging process. You will be alone in the exam room ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... artifacts on the images. This loss of image quality can resemble the blurring seen on a photograph ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  1. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  2. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  4. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  5. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  6. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  7. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  8. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  9. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  10. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  11. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  12. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  13. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  14. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  15. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  16. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  17. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  18. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  19. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Do, Kyung Hyun; Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2% at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  20. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Do, Kyung Hyun; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms. Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and --600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2 % at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  1. Dynamic bowtie filter for cone-beam/multi-slice CT.

    Directory of Open Access Journals (Sweden)

    Fenglin Liu

    Full Text Available A pre-patient attenuator ("bowtie filter" or "bowtie" is used to modulate an incoming x-ray beam as a function of the angle of the x-ray with respect to a patient to balance the photon flux on a detector array. While the current dynamic bowtie design is focused on fan-beam geometry, in this study we propose a methodology for dynamic bowtie design in multi-slice/cone-beam geometry. The proposed 3D dynamic bowtie is an extension of the 2D prior art. The 3D bowtie consists of a highly attenuating bowtie (HB filled in with heavy liquid and a weakly attenuating bowtie (WB immersed in the liquid of the HB. The HB targets a balanced flux distribution on a detector array when no object is in the field of view (FOV. The WB compensates for an object in the FOV, and hence is a scaled-down version of the object. The WB is rotated and translated in synchrony with the source rotation and patient translation so that the overall flux balance is maintained on the detector array. First, the mathematical models of different scanning modes are established for an elliptical water phantom. Then, a numerical simulation study is performed to compare the performance of the scanning modes in the cases of the water phantom and a patient cross-section without any bowtie and with a dynamic bowtie. The dynamic bowtie can equalize the numbers of detected photons in the case of the water phantom. In practical cases, the dynamic bowtie can effectively reduce the dynamic range of detected signals inside the FOV. Furthermore, the WB can be individualized using a 3D printing technique as the gold standard. We have extended the dynamic bowtie concept from 2D to 3D by using highly attenuating liquid and moving a scale-reduced negative copy of an object being scanned. Our methodology can be applied to reduce radiation dose and facilitate photon-counting detection.

  2. The Role of Coronary Computed Tomography Angiography and Cardiac Magnetic Resonance in STEMI Patients with Normal Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Beganu Elena

    2017-09-01

    Full Text Available Usually, the diagnosis of myocardial infarction based on patient symptoms, electrocardiogram (ECG changes, and cardiac enzymes, is not a challenge for cardiologists. The correlation between coronary anatomy and the ECG territories that present ischemic changes can help the clinician to estimate which coronary artery presents lesions upon performing a coronary angiogram. In certain situations, the diagnosis of myocardial infarction can be difficult due to the lack of correlations between the clinical and paraclinical examinations and the coronary angiogram. In some cases, patients with chest pain and ST-segment elevation on the ECG tracing present with a normal coronary angiography. In other cases, patients without important changes on the ECG can present critical lesions or even occlusions upon angiographic examination. The aim of this article is to highlight the role of noninvasive coronary magnetic resonance and multi-slice computed tomography in patients with ST-segment elevation myocardial infarction and normal coronary angiography.

  3. Micro computed tomography features of laryngeal fractures in a case of fatal manual strangulation.

    Science.gov (United States)

    Fais, Paolo; Giraudo, Chiara; Viero, Alessia; Miotto, Diego; Bortolotti, Federica; Tagliaro, Franco; Montisci, Massimo; Cecchetto, Giovanni

    2016-01-01

    Cases of subtle fatal neck compression are often complicated by the lack of specificity of the post-mortem signs of asphyxia and by the lack of clear signs of neck compression. Herein we present a forensic case of a 45-year-old schizophrenic patient found on the floor of the bedroom of a psychiatric ward in cardiopulmonary arrest and who died after two days in a vegetative state. The deposition of the roommate of the deceased, who claimed responsibility for the killing of the victim by neck compression, was considered unreliable by the prosecutor. Autopsy, toxicological analyses, and multi-slice computed tomography (MSCT), micro computed tomography (micro-CT) and histology of the larynx complex were performed. Particularly, micro-CT analysis of the thyroid cartilage revealed the bilateral presence of ossified triticeous cartilages and the complete fragmentation of the right superior horn of the thyroid, but it additionally demonstrated a fracture on the contralateral superior horns, which was not clearly diagnosable at MSCT. On the basis of the evidence of intracartilaginous laryngeal hemorrhages and bilateral microfracture at the base of the superior horns of the larynx, the death was classified as a case of asphyxia due to manual strangulation. Micro-CT was confirmed as a useful tool in cases of subtle fatal neck compression, for the detection of minute laryngeal cartilage fractures, especially in complex cases with equivocal findings on MSCT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, Konstantin; Becker, Christoph R.; Reiser, Maximilian F. [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Flohr, Thomas; Stierstorfer, Karl [CT Division, Siemens Medical Solutions, Forchheim (Germany)

    2005-02-01

    The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024 x 768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25 x 0.25 x 0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed. (orig.)

  5. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  6. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  7. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  8. Duodenal diverticulitis. computed tomography findings

    International Nuclear Information System (INIS)

    Sanchez, E.; Martin, S.; Garcia, J.; Dominguez, A.

    2001-01-01

    Duodenal diverticular occur very frequently among the general public. However, duodenal diverticulitis is a very uncommon clinical entity, the diagnosis of which requires radiological studies since the clinical signs cam mimic a great number of disease processes with different treatments. We present a case of duodenal diverticulitis in which the diagnosis according to ultrasound and computed tomography (CT) studies was confirmed intraoperatively. We also review the few cases of this entity reported in the literature. The CT findings are highly suggestive of duodenal diverticulitis given their similarity to those associated with diverticulitis at other sites. (Author) 5 refs,

  9. Mathematical foundations of computed tomography

    International Nuclear Information System (INIS)

    Smith, K.T.; Keinert, F.

    1985-01-01

    Along with a review of some of the mathematical foundations of computed tomography, the article contains new results on derivation of reconstruction formulas in a general setting encompassing all standard formulas; discussion and examples of the role of the point spread function with recipes for producing suitable ones; formulas for, and examples of, the reconstruction of certain functions of the attenuation coefficient, e.g., sharpened versions of it, some of them with the property that reconstruction at a point requires only the attenuation along rays meeting a small neighborhood of the point

  10. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  11. Brain metastases: computed tomography assessment

    International Nuclear Information System (INIS)

    Gordillo, Victoria; Yagual, Glenda; Vinueza, Clayreth

    1998-01-01

    Intracranial metastatic tumor is relatively frequent in patients with cancer from other origin. Its location and type of metastasis varies in relation to its linage from the primary tumor. And the sequence goes from the most frequent: lung and breast cancer, melanoma, GU tract, leukemia, GI tract, head and neck tumor. Computed tomography findings are extremely varied and non specific, so there are no radiologic characteristics even from the primary tumor. We reviewed 29 TC studies in the Radiology department of ION-SOLCA, from patients with diagnosis of brain metastasis, our findings showed the great variability in the radio-diagnosis imaging. (The author)

  12. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  13. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  14. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  15. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  16. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  17. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  18. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  19. Multi-slicing strategy for the three-dimensional discontinuity layout optimization (3D DLO).

    Science.gov (United States)

    Zhang, Yiming

    2017-03-01

    Discontinuity layout optimization (DLO) is a recently presented topology optimization method for determining the critical layout of discontinuities and the associated upper bound limit load for plane two-dimensional and three-dimensional (3D) problems. The modelling process (pre-processing) for DLO includes defining the discontinuities inside a specified domain and building the target function and the global constraint matrix for the optimization solver, which has great influence on the the efficiency of the computation processes and the reliability of the final results. This paper focuses on efficient and reliable pre-processing of the discontinuities within the 3D DLO and presents a multi-slicing strategy, which naturally avoids the overlapping and crossing of different discontinuities. Furthermore, the formulation of the 3D discontinuity considering a shape of an arbitrary convex polygon is introduced, permitting the efficient assembly of the global constraint matrix. The proposed method eliminates unnecessary discontinuities in 3D DLO, making it possible to apply 3D DLO for solving large-scale engineering problems such as those involving landslides. Numerical examples including a footing test, a 3D landslide and a punch indentation are considered, illustrating the effectiveness of the presented method. © 2016 The Authors. International Journal for Numerical and Analytical Methods in Geomechanics published by John Wiley & Sons Ltd.

  20. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  1. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  2. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  3. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  4. Computed tomography of splenic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-12-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children.

  5. Computed tomography of splenic trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-01-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children

  6. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  7. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  8. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.

    1983-01-01

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  9. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  10. Computed tomography with energy-resolved detection: a feasibility study

    Science.gov (United States)

    Shikhaliev, Polad M.

    2008-03-01

    The feasibility of computed tomography (CT) with energy-resolved x-ray detection has been investigated. A breast CT design with multi slit multi slice (MSMS) data acquisition was used for this study. The MSMS CT includes linear arrays of photon counting detectors separated by gaps. This CT configuration allows for efficient scatter rejection and 3D data acquisition. The energy-resolved CT images were simulated using a digital breast phantom and the design parameters of the proposed MSMS CT. The phantom had 14 cm diameter and 50/50 adipose/glandular composition, and included carcinoma, adipose, blood, iodine and CaCO3 as contrast elements. The x-ray technique was 90 kVp tube voltage with 660 mR skin exposure. Photon counting, charge (energy) integrating and photon energy weighting CT images were generated. The contrast-to-noise (CNR) improvement with photon energy weighting was quantified. The dual energy subtracted images of CaCO3 and iodine were generated using a single CT scan at a fixed x-ray tube voltage. The x-ray spectrum was electronically split into low- and high-energy parts by a photon counting detector. The CNR of the energy weighting CT images of carcinoma, blood, adipose, iodine, and CaCO3 was higher by a factor of 1.16, 1.20, 1.21, 1.36 and 1.35, respectively, as compared to CT with a conventional charge (energy) integrating detector. Photon energy weighting was applied to CT projections prior to dual energy subtraction and reconstruction. Photon energy weighting improved the CNR in dual energy subtracted CT images of CaCO3 and iodine by a factor of 1.35 and 1.33, respectively. The combination of CNR improvements due to scatter rejection and energy weighting was in the range of 1.71-2 depending on the type of the contrast element. The tilted angle CZT detector was considered as the detector of choice. Experiments were performed to test the effect of the tilting angle on the energy spectrum. Using the CZT detector with 20° tilting angle decreased the

  11. Radiological protection in computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. A comparative study of electrocardiogram multi-segment reconstruction and dual source computed tomography using a computer controlled coronary phantom

    International Nuclear Information System (INIS)

    Ohashi, Kazuya; Higashide, Ryo; Kunitomo, Hirosi; Ichikawa, Katsuhiro

    2011-01-01

    Currently, there are two main methods for improving temporal resolution of coronary computed tomography (CT): electrocardiogram-gated multi-segment reconstruction (EMR) and dual source scanning using dual source CT (DSCT). We developed a motion phantom system for image quality assessment of cardiac CT to evaluate these two methods. This phantom system was designed to move an object at arbitrary speeds during a desired phase range in cyclic motion. By using this system, we obtained coronary CT mode images for motion objects like coronary arteries. We investigated the difference in motion artifacts between EMR and the DSCT using a 3-mm-diameter acrylic rod resembling the coronary artery. EMR was evaluated using 16-row multi-slice CT (16MSCT). To evaluate the image quality, we examined the degree of motion artifacts by analyzing the profiles around the rod and the displacement of a peak pixel in the rod image. In the 16MSCT, remarkable increases of artifacts and displacement were caused by the EMR. In contrast, the DSCT presented excellent images with fewer artifacts. The results showed the validity of DSCT to improve true temporal resolution. (author)

  13. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  14. Computed tomography of obstructive jaundice

    International Nuclear Information System (INIS)

    Suh, Jung Hek; Lee, Joong Suk; Chun, Beung He; Suh, Soo Jhi

    1982-01-01

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst

  15. Errors in abdominal computed tomography

    International Nuclear Information System (INIS)

    Stephens, S.; Marting, I.; Dixon, A.K.

    1989-01-01

    Sixty-nine patients are presented in whom a substantial error was made on the initial abdominal computed tomography report. Certain features of these errors have been analysed. In 30 (43.5%) a lesion was simply not recognised (error of observation); in 39 (56.5%) the wrong conclusions were drawn about the nature of normal or abnormal structures (error of interpretation). The 39 errors of interpretation were more complex; in 7 patients an abnormal structure was noted but interpreted as normal, whereas in four a normal structure was thought to represent a lesion. Other interpretive errors included those where the wrong cause for a lesion had been ascribed (24 patients), and those where the abnormality was substantially under-reported (4 patients). Various features of these errors are presented and discussed. Errors were made just as often in relation to small and large lesions. Consultants made as many errors as senior registrar radiologists. It is like that dual reporting is the best method of avoiding such errors and, indeed, this is widely practised in our unit. (Author). 9 refs.; 5 figs.; 1 tab

  16. X-ray computed tomography

    International Nuclear Information System (INIS)

    Kalender, Willi A

    2006-01-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  17. Computed tomography of epileptic children

    International Nuclear Information System (INIS)

    Kurihara, Mana; Yamashita, Sumimasa; Miyake, Shota; Yamada, Michiko; Iwamoto, Hiroko

    1986-01-01

    The aim of this study was to analyze the changes seen on cranial computed tomography (CT) of epileptic children, especially in the area of the temporal horn. The subjects were 242 epileptic children excluding those with encephalitis, brain tumor, neurocutaneous syndromes, degenerative disease, hydrocephalus etc. The control subjects were 195 children without any neurological disease and symptoms. CT scan were taken with a TCT-60A whole body scanner, and 14 check points were evaluated excluding the temporal horn. 195 epileptic children (N-group) and all control children were normal at 14 check points. Next, the areas of the temporal horns and adjoining hemispheres of the epileptic children (N-group) and control children were examined with Muto-Tablet-Desitizer. The temporal horn ratio ((area of temporal horn/area of ipsilateral hemisphere) x 100) was greater in younger children of the control group, and it was higher in epileptic than in control children. Enlargement of the temporal horn was seen in 1 % of the controls and in 35 % of the 125 epileptic children with normal measurements at 14 points on CT scans (p < 0.01). The frequency of enlargement of temporal horns was not variable among different epileptic types. In the epileptic children with normal CT scans except for enlargement of temporal horns behavioral disturbances were 6 boys and 5 had enlarged temporal horns (bilateral 1 case, left side 1 case, right side 3 cases). (author)

  18. Computed Tomography of Interacerebral Hemorrhage

    International Nuclear Information System (INIS)

    Kim, Seung Hyeon; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Park, Soo Soung

    1983-01-01

    Computed tomography (CT) is the most accurate and reliable method for the diagnosis of intracerebral and intraventricular hemorrhage. The precise anatomic extent of the nematoma, associated cerebral edema, ventricular deformity and displacement, and hydrocephalus are all readily assessed. Aside from head trauma, the principal cause of intracerebral hematoma is hypertensive vascular disease. Although hematomas from various causes may present similar CT appearances frequently the correct etiology may be suggested by consideration of patient's age, clinical history, and the location of the hematoma. The analytical study was performed in 180 cases of intracerebral hemorrhages by CT from October 1981 to January 1983. The results were as follows; 1. The most prevalent age group was 6th decade (37.2%). Male was prevalent to female at the ration of 1.6 to 1. 2. The most common symptom and sign was mental disturbance (48.7%), motor weakness (23%), headache (10.6%), nausea and vomiting (9.8%). 3. The causes of hemorrhage were hypertension (53.9%), head trauma (30.6%), aneurysm (6.1%) and A-V malformation (7.2%). 4. The frequent locations of hemorrhage were basal ganglia and thalamus (40.4%), lobes (35%), ventricles (21.8%). 5. The distribution of hemorrhage was intracerebral hemorrhage (65.6%), intracerebral and intraventricular hemorrhage (30.3%), intraventricular hemorrhage (4.4%).

  19. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  20. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  1. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  2. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  3. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  4. Orbital computed tomography for exophthalmos

    International Nuclear Information System (INIS)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo

    1987-01-01

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos

  5. Computed tomography of cerebrovascular accidents

    International Nuclear Information System (INIS)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin

    1989-01-01

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography

  6. Computed tomography of cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1989-10-15

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography.

  7. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  8. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  9. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  10. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  11. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Watzke, Oliver; Kalender, Willi A.

    2001-01-01

    In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region

  12. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  13. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  14. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  15. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  16. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  17. Computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Cho, Bum Shin; Shin, Kyoung Hee; Hahm, Chang Kok

    1982-01-01

    Computed tomography (CT) is a new non-invasive diagnostic imaging method, which has ability to differentiate C.S.F., hematoma, and even edematous brain from normal brain tissue. Prior to the introduction of the CT, the diagnosis of the intraventricular hemorrhage in living patients was difficult and was confirmed by surgery of autopsy. Intracranial hemorrhages are visible on the CT with density higher than brain tissue in acute phase. CT is an accurate method for detecting of intraventricular hemorrhage including detection of nature, location, amount, and associated changes. CT is also useful as a guidance and in the evaluation of fate of the hematomas by easily performable follow up studies. The causes of the intraventricular hemorrhages are hypertension, rupture of aneurysm, arteriovenous malformation, head trauma, brain tumor, and others. This study included evaluation of CT of 69 patients who show the high density in cerebral ventricular system during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 69 patient was broad ranging from 1 month to 80 years. 28% of patients were in the 6th decade. The mate to female ratio was 2 : 1. 2. The consciousness of patients at CT study: Those were conscious in 11 cases, stuporous in 41 cases and unconscious in 17 cases. 3. The causes of intraventricular hemorrhages were hypertension in 28 cases, head trauma in 12 cases, aneurysm in 4 cases, tumor in 2 cases and others in 23 cases. 4. 9 cases showed intraventricular hematomas only, other 60 cases showed associated intracranial hematomas: Those were intracerebral hematomas in 53 cases including 30 cases of basal ganglial and thalamic hematomas, subarachnoid hemorrhage in 17 cases, epidural hematomas in 3 cases, and subdural hematomas in 2 cases. 5. All cases of the intraventricular hematomas except one sowed hematoma in the lateral

  18. Computed tomography in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Lee, Seung Ro; Chang, Kee Hyun; Choi, Byung Ihn; Han, Man Chung; Sim, Bo Sung

    1981-01-01

    Computed Tomography has become increasingly important diagnostic method as the initial examination in the diagnosis of subarachnoid hemorrhage with direct detection of extravasated blood in basal cistern and cortical sulci. Furthermore, CT provides better and exact visualization of the presence, localization, extent and degree of intracerebral, intraventricular and subdural hemorrhage, infarction, hydrocephalus and rebleeding which may be associated with subarachnoid hemorrhage, and also could detect the causative lesions with contrast enhancement in many cases. The purpose of the paper is to describe the CT findings of subarachnoid hemorrhage due to various causes and to evaluate the diagnostic accuracy of CT in subarachnoid hemorrhage. Authors analysed a total of 153 cases with subarachnoid hemorrhage confirmed by lumbar puncture at Seoul National University Hospital from March 1979 to April 1981, with special emphasis on CT findings. All of the cases took CT scan and 125 cases of them angiography. The results are as follows: 1. Most prevalent age group was 4th to 6th decades (78%). The ratio of male to female was 1.1: 1. 2. Of 125 cases with angiography, aneurysm was a major cause (68%). Others were arterio-venous malformation (9.6%), Moya-moya disease (4%) and unknown (18.4%). 3. Of all 153 cases with CT scan, hemorrhage was demonstrated in 98 cases (64.1%); SAH in 72 cases (47.1%), ICH in 65 cases (42.5%), IVH in 34 cases (22.2%) and SDH in 1 case (0.7%). SAH combined with ICH was a major group (34.7%) in SAH. Detection rate of SAH was 68.3% within the first 7 days and 5.8% after 7 dyas. 4. In aneurysms, SAH was detected in 60 of 85 cases (70.6%); 88.1% within the first 7 dyas and 5.6% after 7 dyas. Anterior communicating artery was the most common site of the aneurysms (40%), in which detection rate of SAH was 100% within the first 7 days. SAH was combined with ICH in 38.3%. 5. On CT, SAH of unilateral Sylvian fissure was pathognomonic for ruptured MCA

  19. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  20. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  1. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  2. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  3. Blood flow patterns of solitary pulmonary nodules with enhancement: clinical value of multi-slice spiral CT

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Liu Huimin; Li Yuli; Li Huimin; Li Chengzhou; Zhang Chenshi; Tao Zhiwei; Yang Chunshan; Jiang Qingjun; Ouyang Lin; Yu Hong

    2004-01-01

    Objective: To evaluate the efficacy of dynamic multi-slice spiral computed tomography (MSCT) for providing quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs) and the correlation of vascular endothelial growth factor (VEGF)-positive tumor angiogenesis and the quantifiable parameters of blood flow pattern in solitary bronchogenic adenocarcinoma. Methods Seventy-eight patients with SPNs (with strong enhancement) (diameter ≤4 cm; 68 malignant; 10 active inflammatory) underwent multi-location dynamic contrast enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4 ml/s by using an autoinjector) serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion, peak height, and ratio of peak height of the SPN to that of the aorta were calculated. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. The quantifiable parameters (perfusion, peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta and mean transit time) of blood flow pattern in 30 VEGF-positive solitary bronchogenic adenocarcinoma were compared with microvessel densities (MVD) and VEGF expression by immunohistochemistry. Results: No statistically significant difference in the peak height was found between malignant (35.79 ± 10.76) HU and active inflammatory (39.76 ± 4.59) HU nodules (t=1.148, P=0.255). SPN-to-aorta ratio (14.27 ± 4.37)% and perfusion value (3.02 ± 0.96)ml -1 ·min -1 ·kg -1 in malignant SPNs were significantly lower than those of active inflammatory nodules(18.51 ± 2.71)%, (6.34 ± 4.39)ml -1 ·min -1 ·kg -1 (t=2.978, P=0.004, t=5.590, P -1 ·min -1 ·kg -1 , mean transit time (14.86 ± 5.84) s, and MVD (70.15 ± 20.03). Each of peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta, and perfusion correlated positively with MVD (r=0.781, P<0.0001; r=0

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which rotates around the patient. The computer that processes the imaging information and monitor are located in ... follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  6. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  7. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  8. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  9. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  10. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  11. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  12. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  13. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  14. PET/CT和MSCT联合应用在孤立性肺结节诊断中的价值%PET-CT with multi-slice spiral CT in the diagnosis of SPN

    Institute of Scientific and Technical Information of China (English)

    汪世存; 方雷; 潘博; 展凤麟; 谢强; 谢吉奎

    2009-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射显像/电子计算机断层扫描成像(18F-deoxyglucose positron emission tomography /computer tomography 18F-FDG PET/CT)和多排CT( multi-slice spiral CT,MSCT)联合应用在孤立性肺结节(SPN)诊断中的价值.方法 87例SPN患者均行PET/CT及肺部病灶MSCT检查,影像诊断结果 与病理对照,进行统计分析.结果 87例SPN中,MSCT诊断正确64例,误诊23例,误诊率26.4%.PET/CT诊断正确70例,误诊17例,误诊率19.5%.MSCT和PET/CT联合诊断,80例诊断正确,7例误诊,误诊率8.0%.MSCT、PET/CT及两者联合诊断的敏感性、特异性和准确性分别为87.2%、68.1%、79.8%;89.5%、61.3%、81.4%和97.7%、74.2%、91.5%.MSCT和PET/CT单独诊断SPN的准确性无统计学意义(χ2=0.625,P=0.239),MSCT、PET/CT与两者联合应用诊断SPN的准确性均有统计学意义(χ2=7.762和5.318,P=0.005和0.021).结论 SPN的MSCT和PET/CT影像特征均有一定的重叠.单独采用MSCT或PET/CT诊断肺结节无明显统计学差异,MSCT和PET-CT协同诊断的准确性高于MSCT或PET/CT单独诊断.%Aim To evaluate the value of a combination of 18F-FDG PET-CT with multi-slice spiral CT in the diagnosis of SPN.Methods 18F-FDG PET-CT and multi-slice spiral CT were performed in 87 patients with SPN.The pathologically-proved findings were compared with findings diagnosed by MSCT and retrospectively analyzed.Results In 87 cases,the numbers of correct diagnosis and misdiagnosis with MSCT were 64 and 23 respectively,the misdiagnosis rate 26.4%,while the numbers of correct diagnosis and misdiagnosis with PET/CT were 70 and 17,the misdiagnosis rate 19.5%,but 50 cases were correctly diagnosed and 7 cases were misdiagnosed by combining 18F-FDG PET-CT with MSCT,the misdiagnosis rate 8.0%.The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of MSCT,PET/CT,and MSCT combined with PET /CT were 87.2%,68.1%,79.8%;89.5%,61.3%,81.4% and 97

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... so that the x-ray beam follows a spiral path. A special computer program processes this series ... Sometimes ultrasound is substituted for CT as a method of imaging in these procedures in children. A ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... diabetes, kidney disease or thyroid problems. Any of these conditions may influence the decision on whether contrast ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  20. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  1. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  2. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  3. Computed tomography - old ideas and new technology

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik; Boas, F.E. [Stanford University, School of Medicine, Department of Radiology, Stanford, CA (United States)

    2011-03-15

    Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

  4. Computed tomography in the evaluation of trauma

    International Nuclear Information System (INIS)

    Federle, M.P.; Brant-Zawadzki, M.

    1982-01-01

    This book is intended to be the current standard for computed tomography in the evaluation of trauma. It summarizes two years of experience at San Francisco General Hospital. The book is organized into seven chapters, covering head, maxillofacial, laryngeal, spinal, chest, abdominal, acetabular, and pelvic trauma. Extremity trauma is not discussed

  5. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  6. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  7. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  8. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  9. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  10. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  11. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  12. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  13. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  14. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  15. Computed tomography in severe protein energy malnutrition.

    OpenAIRE

    Househam, K C; de Villiers, J F

    1987-01-01

    Computed tomography of the brain was performed on eight children aged 1 to 4 years with severe protein energy malnutrition. Clinical features typical of kwashiorkor were present in all the children studied. Severe cerebral atrophy or brain shrinkage according to standard radiological criteria was present in every case. The findings of this study suggest considerable cerebral insult associated with severe protein energy malnutrition.

  16. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  17. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  18. Computed tomography of tuberculous meningitis

    International Nuclear Information System (INIS)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto

    1982-01-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis. (author)

  19. Misty mesentery: computed tomography findings

    International Nuclear Information System (INIS)

    Ahualli, Jorge; Mendez Uriburu, Luis; Ravera, Maria L.; Cikman, Pablo

    2008-01-01

    An alteration in the density of the mesenteric adipose tissue is often the principal clue of underlying mesenteric and bowel disease. The term 'Misty Mesentery' describes the computed tomographic appearance of mesenteric fat infiltrated by inflammatory cells, fluid (edema, lymph, and/or blood), tumor, and fibrosis. (author) [es

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  2. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    was not used. Autopsies were performed according to the Danish government's official guidelines. PMCT and autopsy findings were interpreted independent of each other. Diagnoses, including the cause of death and histology findings, were registered in a computer database (SPSS) together with information about...

  3. Computed tomography in Alexander's disease

    Energy Technology Data Exchange (ETDEWEB)

    Holland, I M; Kendall, B E

    1980-10-01

    Two cases of biopsy-proven Alexander's disease are described with computed tomographic changes which, in our experience and on survey of the literature, have not occurred in any other condition. Such changes in a child with a progressive condition consistent with Alexander's disease, strongly support the diagnosis.

  4. Computed tomography of limy bile

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Kimoto, Masatoshi; Gunge, Nobuharu; Sano, Kaizo; Yamashita, Sachiko; Hirano, Yutaka

    1983-01-01

    The computed tomographic appearance of three cases of limy bile was reported. The CT findings consist of uniform high density within gallbladder, niveau formation between limy bile and noncalcified bile. Sagittal reconstruction of CT images was especially useful in the differentiation of limy bile and gallstones. (author)

  5. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  6. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  7. A multi-slice gradient sequence for contrast enhanced MR diagnosis of intracranial tumours

    International Nuclear Information System (INIS)

    Schoerner, W.; Sander, B.; Kornmesser, W.; Laniado, M.; Nakamura, T.; Felix, R.

    1988-01-01

    A multi-slice gradient echo sequence (FLASH) was compared with a conventional spin-echo (SE) technique with regard to its value for contrast enhanced MR diagnosis. In 28 patients with cerebral tumours, SE images (SE 400/30; four images/3.4 minutes) and FLASH images (FLASH 315/14; 15 images/1.4 minutes) were obtained before and after gadolinium DTPA. After gadolinium-DTPA results were comparable for both techniques with respect to contrast enhancement, tumor contrast and delineation. Because of the higher efficiency of the FLASH 315/14 technique, this sequence is the method of choice for contrast enhanced cerebral MR imaging. (orig.) [de

  8. Thermoluminescent dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  9. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  10. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-01-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  11. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  12. Microfocus computed tomography in medicine

    Science.gov (United States)

    Obodovskiy, A. V.

    2018-02-01

    Recent advances in the field of high-frequency power schemes for X-ray devices allow the creation of high-resolution instruments. At the department of electronic devices and Equipment of the St. Petersburg State Electrotechnical University, a model of a microfocus computer tomograph was developed. Used equipment allows to receive projection data with an increase up to 100 times. A distinctive feature of the device is the possibility of implementing various schemes for obtaining projection data.

  13. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  14. Computed tomography of thymic abnormalities

    International Nuclear Information System (INIS)

    Schnyder, P.; Candardjis, G.

    1987-01-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis. (orig.)

  15. Orbital computed tomography: technical aspects

    International Nuclear Information System (INIS)

    Beck, T.J.; Rosenbaum, A.E.; Miller, N.R.

    1982-01-01

    Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion

  16. Proton computed tomography images with algebraic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzi, M. [Physics and Astronomy Department, University of Florence, Florence (Italy); Civinini, C.; Scaringella, M. [INFN - Florence Division, Florence (Italy); Bonanno, D. [INFN - Catania Division, Catania (Italy); Brianzi, M. [INFN - Florence Division, Florence (Italy); Carpinelli, M. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Presti, D. Lo [INFN - Catania Division, Catania (Italy); Physics and Astronomy Department, University of Catania, Catania (Italy); Maccioni, G. [INFN – Cagliari Division, Cagliari (Italy); Pallotta, S. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Randazzo, N. [INFN - Catania Division, Catania (Italy); Romano, F. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Sipala, V. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Talamonti, C. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Vanzi, E. [Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena (Italy)

    2017-02-11

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to ~1% and spatial resolutions <1 mm, achieved within processing times of ~15′ for a 512×512 pixels image prove that this technique will be beneficial if used instead of X-CT in hadron-therapy.

  17. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  18. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  19. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  20. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  1. Computed tomography of the menisci

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.; Rupp, N.; Paar, O.; Rodammer, G.

    1988-01-01

    Thirty patients were examined with CT of the menisci. All findings were confirmed by arthroscopy. One false positive diagnosis of a torn meniscus was made, caused by partial volume effect. In seven patients with irregular degenerative changes of the menisci, the abnormality could be clearly demonstrated. One meniscus ganglion was shown. Seven meniscus lesions, which were not shown by arthrography or arthroscopy, were clearly demonstrated by CT. The computer tomographic demonstration of menisci can replace knee arthrography as the examination of choice and should be performed before carrying out arthroscopy. (orig.) [de

  2. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  3. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  4. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  5. Late enhanced computed tomography in Hypertrophic Cardiomyopathy enables accurate left-ventricular volumetry

    Energy Technology Data Exchange (ETDEWEB)

    Langer, Christoph; Lutz, M.; Kuehl, C.; Frey, N. [Christian-Albrechts-Universitaet Kiel, Department of Cardiology, Angiology and Critical Care Medicine, University Medical Center Schleswig-Holstein (Germany); Partner Site Hamburg/Kiel/Luebeck, DZHK (German Centre for Cardiovascular Research), Kiel (Germany); Both, M.; Sattler, B.; Jansen, O; Schaefer, P. [Christian-Albrechts-Universitaet Kiel, Department of Diagnostic Radiology, University Medical Center Schleswig-Holstein (Germany); Harders, H.; Eden, M. [Christian-Albrechts-Universitaet Kiel, Department of Cardiology, Angiology and Critical Care Medicine, University Medical Center Schleswig-Holstein (Germany)

    2014-10-15

    Late enhancement (LE) multi-slice computed tomography (leMDCT) was introduced for the visualization of (intra-) myocardial fibrosis in Hypertrophic Cardiomyopathy (HCM). LE is associated with adverse cardiac events. This analysis focuses on leMDCT derived LV muscle mass (LV-MM) which may be related to LE resulting in LE proportion for potential risk stratification in HCM. N=26 HCM-patients underwent leMDCT (64-slice-CT) and cardiovascular magnetic resonance (CMR). In leMDCT iodine contrast (Iopromid, 350 mg/mL; 150mL) was injected 7 minutes before imaging. Reconstructed short cardiac axis views served for planimetry. The study group was divided into three groups of varying LV-contrast. LeMDCT was correlated with CMR. The mean age was 64.2 ± 14 years. The groups of varying contrast differed in weight and body mass index (p < 0.05). In the group with good LV-contrast assessment of LV-MM resulted in 147.4 ± 64.8 g in leMDCT vs. 147.1 ± 65.9 in CMR (p > 0.05). In the group with sufficient contrast LV-MM appeared with 172 ± 30.8 g in leMDCT vs. 165.9 ± 37.8 in CMR (p > 0.05). Overall intra-/inter-observer variability of semiautomatic assessment of LV-MM showed an accuracy of 0.9 ± 8.6 g and 0.8 ± 9.2 g in leMDCT. All leMDCT-measures correlated well with CMR (r > 0.9). LeMDCT primarily performed for LE-visualization in HCM allows for accurate LV-volumetry including LV-MM in > 90 % of the cases. (orig.)

  6. Radiation doses in pediatric computed tomography procedures: challenges facing new technologies

    International Nuclear Information System (INIS)

    Cotelo, E.; Padilla, M.; Dibarboure, L.

    2008-01-01

    Despite the fact that in recent years an increasing number of radiologists and radiological technologists have been applying radiation dose optimization techniques in paediatric Computed Tomography (CT) examinations, dual and multi -slice CT (MSCT) scanners present a new challenge in Radiation Protection (RP). While on one hand these scanners are provided with Automatic Exposure Control (AEC) devices, dose reduction modes and dose estimation software, on the other hand Quality Control (QC) tests and CT Kerma Index (C) measurements and patient dose estimation present specific difficulties and require changes or adaptations of traditional QC protocols. This implies a major challenge in most developing countries where Quality Assurance Programmes (QAP) have not been implemented yet and there is a shortage in the number of medical physicists This paper analyses clinical and technical protocols as well as patient doses in 204 CT body procedures performed in 154 children. The investigation was carried out in a paediatric reference hospital of Uruguay, where are performed an average of 450 paediatric CT examinations per month in a sole CT dual scanner. Besides, C VOL reported from the scanner display was registered in order to be related with the same dosimetric quantity derived from technical parameters and C values published on tables. Results showed that not all the radiologists applied the same protocol in similar clinical situations delivering unnecessary patient dose with no significant differences in image quality. Moreover, it was found that dose reduction modes represent a drawback in order to estimate patient dose when mA changes according to tissue attenuation, in most cases in each rotation. The study concluded on the importance of QAP that must include education on RP of radiologists and technologists, as well as in the need of medical physicists to perform QC tests and patient dose estimations and measurements. (author)

  7. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  8. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  9. Study of dosimetric quantities and image quality in pediatric examinations of chest and abdomen computed tomography

    International Nuclear Information System (INIS)

    Jornada, Tiago da Silva

    2013-01-01

    This work had the objective to achieve the knowledge of the dosimetric quantities related to chest and abdomen computed tomography (CT) examinations of pediatric patients, in Belo Horizonte city. The reason of this work is based on the fact that the probability of health detriment in children, which it may be caused by radiation, is higher than in adults. Besides, although in many countries the knowledge and control of patient doses is a normal procedure, this safety culture does not exist in Brazil. Another objective of this work was to compare the dosimetric quantity values with the Diagnostic Reference Levels (DRLs); when it was needed, an optimization process was applied and the quality of the diagnostic image obtained with the optimized technical parameters was analyzed. This study was carried out in five hospitals, where the weighted air kerma index (Cw), the volumetric air kerma index (Cvol), the air kerma - length product (PKL,CT), the Effective Dose (E) and the Normalized Effective Dose (En) were determined; three methods were adopted for measurements: the ionization chamber inside a chest pediatric phantom, radiochromic films and the CT-EXPO software. The optimization process was applied to a single hospital through variations in the current (mA) and voltage (kV) of the x-ray tube for the protocols used for abdomen CT examinations. The analysis of the quality of the diagnostic image was done by Normal Distribution and ROC analysis; spatial resolution analysis was used through MTF determination and the noise level was judged in terms quantitative and qualitative. Results of the dosimetric quantities showed that they significantly differed between single-slice and multi-slice tomography units, but their values were always below the recommended DRLs. The optimized values of the dosimetric quantities obtained after the optimization process showed that it was possible to reduce the radiation exposure of pediatric patient without losing the image quality

  10. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  11. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  12. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  13. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  14. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  15. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  16. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  17. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  18. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  19. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  20. Xenon as an adjunct in computed tomography

    International Nuclear Information System (INIS)

    Kendall, B.E.; Radue, E.W.; Zilkha, E.; Loh, L.

    1979-01-01

    Nonradioactive xenon was used for enhancement in computed tomography in a series of 18 patients requiring general anesthesia. The method and results are described. The properties of xenon are radically different from those of intravenous iodides, and the enhancement patterns demonstrate different aspects of both normal and abnormal tissues. In our limited experience, it has been of value in those isodense and low attenuation lesions that have not enhanced after intravenous Conray. (orig.) 891 MG/orig. 892 MB [de

  1. Computed tomography of the eye and orbit

    International Nuclear Information System (INIS)

    Hammerschlag, S.B.; Hesselink, J.R.; Weber, A.L.

    1982-01-01

    This book is the product of the evolution of computed tomography (CT) into subspecialization and the need for one source of information for the busy radiologist. The authors have succeeded in providing a readable overview of orbital CT as well as a reference book. The book is divided into seven major catagories of pathology (Neurofibromatosis, Primary Orbital Neoplasms, Secondary and Metastic Tumors of the Orbit, Vascular Disorders, Inflammatory Disease, Occular Lesions, and Trauma) after separate discussions of anatomy and technique

  2. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  3. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Hartelius, H.

    1988-01-01

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  4. Cranial computed tomography of the neurofibromatosis

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Shibakiri, Ippei

    1981-01-01

    The computed tomography (CT) was performed in 10 cases of neurofibromatosis. The CT scan showed the abnormal findings in 8 cases out of 10. Skull lesions were noted in 3 cases and intracranial tumors were found in 5 among which multiple neoplasms were seen in 3. Although reported cases were not large enough in number, the incidence and variety of the tumors were similar to others reported before CT era. (author)

  5. Computed tomography manifestations of peritoneal diseases

    International Nuclear Information System (INIS)

    Gordon, K.; Lee, W.K.; Hennessy, O.

    2005-01-01

    The peritoneal cavity is a potential space that is divided by the peritoneal reflections into various complex subspaces. It can be involved in many disease processes including developmental, inflammatory, neoplastic and traumatic conditions. Computed tomography is highly sensitive and consistent in detecting peritoneal pathology. This pictorial essay aims to emphasize and illustrate the CT features of the spectrum of peritoneal diseases. Copyright (2005) Blackwell Science Pty Ltd

  6. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  7. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  8. Fatty kidney diagnosed by mortem computed tomography

    DEFF Research Database (Denmark)

    Leth, P. M.

    2016-01-01

    Subnuclear vacuolization of the renal tubular epithelium is indicative of diabetic and alcoholic ketoacidosis and has also been proposed as a postmortem marker for hypothermia. We present for the first time a fatal case of ketoacidosis in combination with exposure where a suspicion of these diagn...... of these diagnoses was raised by a marked radiolucency of the kidneys at post-mortem computed tomography (PMCT). © 2015 Elsevier Ltd....

  9. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  10. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  11. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  12. Basic principles of cone beam computed tomography.

    Science.gov (United States)

    Abramovitch, Kenneth; Rice, Dwight D

    2014-07-01

    At the end of the millennium, cone-beam computed tomography (CBCT) heralded a new dental technology for the next century. Owing to the dramatic and positive impact of CBCT on implant dentistry and orthognathic/orthodontic patient care, additional applications for this technology soon evolved. New software programs were developed to improve the applicability of, and access to, CBCT for dental patients. Improved, rapid, and cost-effective computer technology, combined with the ability of software engineers to develop multiple dental imaging applications for CBCT with broad diagnostic capability, have played a large part in the rapid incorporation of CBCT technology into dentistry. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  14. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  15. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  16. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  17. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  18. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  19. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  20. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  1. A simultaneous multi-slice selective J-resolved experiment for fully resolved scalar coupling information

    Science.gov (United States)

    Zeng, Qing; Lin, Liangjie; Chen, Jinyong; Lin, Yanqin; Barker, Peter B.; Chen, Zhong

    2017-09-01

    Proton-proton scalar coupling plays an important role in molecular structure elucidation. Many methods have been proposed for revealing scalar coupling networks involving chosen protons. However, determining all JHH values within a fully coupled network remains as a tedious process. Here, we propose a method termed as simultaneous multi-slice selective J-resolved spectroscopy (SMS-SEJRES) for simultaneously measuring JHH values out of all coupling networks in a sample within one experiment. In this work, gradient-encoded selective refocusing, PSYCHE decoupling and echo planar spectroscopic imaging (EPSI) detection module are adopted, resulting in different selective J-edited spectra extracted from different spatial positions. The proposed pulse sequence can facilitate the analysis of molecular structures. Therefore, it will interest scientists who would like to efficiently address the structural analysis of molecules.

  2. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  3. Systematic procedure for identifying the five main ossification stages of the medial clavicular epiphysis using computed tomography: a practical proposal for forensic age diagnostics.

    Science.gov (United States)

    Wittschieber, Daniel; Schulz, Ronald; Pfeiffer, Heidi; Schmeling, Andreas; Schmidt, Sven

    2017-01-01

    In forensic age estimations of living individuals, computed tomography of the clavicle is widely used for determining the age of majority. To this end, the degree of ossification of the medial clavicular epiphysis can be determined by means of two classification systems complementing each other: a 5-stage system and an additional 6-stage system that further sub-classifies the stages 2 and 3. In recent years, practical experience and new data revealed that difficulties and even wrong stage determinations may occur especially when following the short descriptions of the fundamental 5-stage system only. Based on current literature, this article provides a systematic procedure for identifying the five main ossification stages by listing important preconditions and presenting an algorithm that is comprised of four specific questions. Each question is accompanied by comprehensive and detailed descriptions which specify the criteria used for differentiation. The information is subdivided into "single-slice view" and "multi-slice view." In addition, illustrative case examples and schematic drawings facilitate application of the procedure in forensic practice. The pitfalls associated with the criteria of stage determination will be discussed in detail. Eventually, two general rules will be inferred to assign correct ossification stages of the medial clavicular epiphysis by means of computed tomography.

  4. Evaluation by multislice computed tomography of atherosclerotic coronary artery plaques in non-culprit, remote coronary arteries of patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Kunimasa, Taeko; Sugi, Kaoru; Moroi, Masao; Sato, Yuichi

    2005-01-01

    Patients with acute coronary syndrome (ACS) frequently have vulnerable plaques in the remote coronary arteries, suggesting that ACS is part of the pan-coronary process. In the present study the computed tomography (CT) plaque density in non-culprit atherosclerotic coronary artery lesions was evaluated by multi-slice computed tomography (MSCT) in patients with ACS and non-ACS. MSCT was performed in 21 patients with ACS and 53 patients with non-ACS: 16 of the 21 ACS patients (76%) and 30 of the non-ACS 53 patients (57%) had non-calcified plaques in the non-culprit coronary arteries (p=0.18). CT-low-density plaques (CT density <68 Hounsfield units (HU)) were more frequent in the ACS group (13/16 patients, 81%) than in the non-ACS group (13/30 patients, 43%, p=0.03). In addition, the CT density of the non-culprit lesion was significantly lower in patients with ACS than in those with non-ACS (44.1±22.9 and 77.3±33.7 HU, respectively). Patients with ACS more frequently had CT-low-density plaques in the non-culprit, remote arteries than those with non-ACS, which suggests that ACS treatment should focus not only on stabilizing the culprit lesion but also on systemic stabilization of non-culprit lesions. (author)

  5. Performance of cone beam computed tomography in comparison to conventional imaging techniques for the detection of bone invasion in oral cancer.

    Science.gov (United States)

    Linz, C; Müller-Richter, U D A; Buck, A K; Mottok, A; Ritter, C; Schneider, P; Metzen, D; Heuschmann, P; Malzahn, U; Kübler, A C; Herrmann, K; Bluemel, C

    2015-01-01

    Detecting bone invasion in oral cancer is crucial for therapy planning and the prognosis. The present study evaluated cone beam computed tomography (CBCT) for detecting bone invasion in comparison to standard imaging techniques. A total of 197 patients with diagnoses of oral cancer underwent CBCT as part of preoperative staging between January 2007 and April 2013. The sensitivity, specificity, and accuracy of CBCT were compared with panoramic radiography (PR), multi-slice computed tomography (CT) or magnetic resonance imaging (MRI), and bone scintigraphy (BS) using McNemar's test. Histopathology and clinical follow-up served as references for the presence of bone invasion. CBCT and BS (84.8% and 89.3%, respectively), as well as CBCT and CT/MRI (83.2%), showed comparable accuracy (P = 0.188 and P = 0.771). CBCT was significantly superior to PR, which was reconstructed based on a CBCT dataset (74.1%, P = 0.002). In detecting bone invasion, CBCT was significantly more accurate than PR and was comparable to BS and CT/MRI. However, each method has certain advantages, and the best combination of imaging methods must be evaluated in prospective clinic trials. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  7. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  8. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  9. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  10. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  11. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  12. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  13. Computed tomography appearances of sclerosing encapsulating peritonitis

    International Nuclear Information System (INIS)

    George, C.; Al-Zwae, K.; Nair, S.; Cast, J.E.I.

    2007-01-01

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP

  14. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  15. Application of protons to computer tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.; Bradbury, J.N.; Cannon, T.M.; Hutson, R.L.; Laubacher, D.B.; Macek, R.; Paciotti, M.A.; Taylor, C.A.

    1977-01-01

    It was demonstrated that the application of protons to computed tomography can result in a significant dose advantage relative to x rays. Thus, at the same dose as is delivered by contemporary commercial x-ray scanners, a proton scanner could produce reconstructions with a factor of 2 or more improvement in density resolution. Whether such an improvement can result in significantly better diagnoses of human disease is an open question which can only be answered by the implementation of a proton scanner in a clinical situation

  16. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  17. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  18. Computed tomography of the spine: Diagnostic exercises

    International Nuclear Information System (INIS)

    Kricun, R.; Kricun, M.E.

    1987-01-01

    The authors' aim is to provide diagnostic challenges and information to improve the readers' ability to interpret computed tomography (CT) scans of the spine. The entire vertebral column and adjacent soft-tissue structures are covered. The authors discuss normal findings, and congenital, traumatic, inflammatory, neoplastic, degenerative, idiopathic, and postoperative findings. Sixty-six case examples are presented, followed by description of the findings. Additional examples are given, and drawings and photographs of specimens are used to illustrate and clarify the pathologic conditions. Other modalities, including their advantages and disadvantages, are illustrated and discussed where appropriate. The relative merits of these modalities are presented

  19. Computed tomography features of small bowel volvulus

    International Nuclear Information System (INIS)

    Loh, Y.H.; Dunn, G.D.

    2000-01-01

    Small bowel volvulus is a cause of acute abdomen and commonly occurs in neonates and young infants. Although it is rare in adults in the Western world,' it is a relatively common surgical emergency in the Middle East, India and Central Africa. It is associated with a mortality rate of 10-67% and, hence, it is important to make an early diagnosis to expedite surgical intervention. Computed tomography has become an important imaging modality in diagnosis and a number of signs have been recognized in a handful of documented case reports. We describe a case of small bowel volvulus that illustrates these important CT signs. Copyright (1999) Blackwell Science Pty Ltd

  20. Computed tomography in neuronal ceroid lipofuscinosis

    International Nuclear Information System (INIS)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neutronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter. (orig.) [de

  1. Unusual causes of obstructive jaundice. Computed tomography

    International Nuclear Information System (INIS)

    Rodriguez, E.; Pombo, F.; Cao, I.; Fernandez, R.; Riba da, M.

    1998-01-01

    The purpose of this study is to present selected computed tomography (CT) images showing unusual causes of obstructive jaundice. We reviewed retrospectively the Ct findings of obstructive jaundice in 227 patients. The most common causes of biliary obstruction were adenocarcinoma of the pancreatic head (n=77) and cholangiocarcinoma (n=65). In 13 cases (5.7%), the etiology of obstructive jaundice was unusual or exceptional: tuberculous adenitis (n=3), obstruction of afferent loop (n=2)signet ring cell adenocarcinoma (n=3); in duodenum, gallbladder and papilla of Water), Mirizzi syndrome (n=1), adenocarcinoma of the hepatic flexure (n=1), choledochal cyst (n=1) and pancreatic lymphoma (n=1). (Author) 13 refs

  2. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  3. Cine CT: a new technology for cardiac computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.; Peschmann, K.R.; Rand, R.E.; Napel, S.A.; Gould, R.; Farmer, D.W.; Lipton, M.J.; Higgins, C.B.; Couch, J.L.

    1987-01-01

    The technical requirements for adequate evaluation of cardiac anatomy and physiology, namely scan speeds in the 33-100 msec range, simultaneous multi-slice capability, 15-20 multi-level scans/second and a repeat multi-slice study at one per second, have been realized with the inception of the Cine-CT scanner. This scanner acquires scan data in 50 milliseconds by eliminating moving parts and using a scanning electron beam to produce a high speed X-ray source. The authors describe this scanner and the three scanning modes available: continuous or cine mode; flow or triggered mode; and full resolution mode. (Auth.)

  4. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  5. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  6. Speeding up image reconstruction in computed tomography

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    Computed tomography (CT) is a technique for imaging cross-sections of an object using X-ray measurements taken from different angles. In last decades a significant progress has happened there: today advanced algorithms allow fast image reconstruction and obtaining high-quality images even with missing or dirty data, modern detectors provide high resolution without increasing radiation dose, and high-performance multi-core computing devices are there to help us solving such tasks even faster. I will start with CT basics, then briefly present existing classes of reconstruction algorithms and their differences. After that I will proceed to employing distinctive architectural features of modern multi-core devices (CPUs and GPUs) and popular program interfaces (OpenMP, MPI, CUDA, OpenCL) for developing effective parallel realizations of image reconstruction algorithms. Decreasing full reconstruction time from long hours up to minutes or even seconds has a revolutionary impact in diagnostic medicine and industria...

  7. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  8. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  9. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  10. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  11. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  12. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  13. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  14. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  15. Technological Evolution on Computed Tomography and Radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2006-05-15

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  16. Computed tomography of the traumatized abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki [Wallace Memotial Baptist Hospital, Pusan (Korea, Republic of)

    1989-02-15

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries.

  17. Computed tomography of the traumatized abdomen

    International Nuclear Information System (INIS)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1989-01-01

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries

  18. Multidetector Computed Tomography and Neuroendocrine Pancreaticoduodenal Tumors

    International Nuclear Information System (INIS)

    Rappeport, E.D.; Palnaes Hansen, C.; Kjaer, A.; Knigge, U.

    2006-01-01

    Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs). Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies. Results: Patients with surgery : 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery : In 4 out of 9 patients, no NPTs were identified at MDCT. Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT

  19. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  20. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho

    2006-01-01

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  1. The temporomandibular joint in computed tomography

    International Nuclear Information System (INIS)

    Pomaroli, A.; Lener, M.

    1988-01-01

    The first part describes details of the temporomandibular joint (TMJ) which are of interest for the examination by computed tomography. In the second part three new planes of reference for scanning of the ventral, middle or dorsal part of the joint are presented. CT examinations were made of 14 TMJ of corpses to identify the medial or ventral parts of the articular disc, medial wall of the articular capsule and medial or triangular recessus to achieve this were scanned the corpses with opened and closed mouth, as well as with closed sets of teeth using a sort of hypomochlion in the molar region to distract the TMJ. More over we applicated different contrast mediums like air and niob. (orig.) [de

  2. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  3. Computed tomography study of otitis media

    International Nuclear Information System (INIS)

    Bahia, Paulo Roberto Valle; Marchiori, Edson

    1997-01-01

    The findings of computed tomography (CT) of 89 patients clinically suspected of having otitis media were studied in this work. Such results were compared to clinical diagnosis, otoscopy, surgical findings and previous data. Among the results of our analysis, we studied seven patients with acute otitis media and 83 patients with chronic otitis media. The patients with acute otitis media have undergone CT examinations to evaluate possible spread to central nervous system. The diagnosis of cholesteatoma, its extension and complications were the main indication. for chronic otitis media study. The main findings of the cholesteatomatous otitis were the occupation of the epitympanun, the bony wall destruction and the ossicular chain erosion. The CT demonstrated a great sensibility to diagnose the cholesteatoma. (author)

  4. Diagnosis of cerebral disorders using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, K [Tokyo Women' s Medical Coll. (Japan)

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT.

  5. Diagnosis of cerebral disorders using computed tomography

    International Nuclear Information System (INIS)

    Kitamura, Koichi

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT. (Nishio, M.)

  6. The dynamic micro computed tomography at SSRF

    Science.gov (United States)

    Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.

    2018-05-01

    Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.

  7. Computed tomography of the pituitary gland

    International Nuclear Information System (INIS)

    Bonneville, J.F.; Cattin, F.; Dietemann, J.L.

    1986-01-01

    This book is written entirely to include the imaging of the pituitary gland by computed tomography (CT). The first three chapters illustrated technical aspects of scanning, anatomic depiction of the gland by CT, and the use of dynamic CT scanning for detecting and displaying abnormalities. The chapters discuss and illustrate various types of pathologic processes in and around the pituitary gland. One short but very helpful chapter demonstrates potential pitfalls due to the combination of anatomic variants and the geometry of CT sections. Some illustrations of disease processed are depicted by magnetic resonance imaging. All major types of pituitary diseases are illustrated. Lists of readily available English-language references are available. A small subject index is provided at the end of the book in which the illustrations are identified by use of a special numeric front

  8. Ward nurses' knowledge of computed tomography scanning.

    Science.gov (United States)

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  9. Computed tomography study of Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, H; Kobayashi, K; Ikeda, Y; Nagao, Y; Ogihara, R; Kosaka, K

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease.

  10. Practical techniques for pediatric computed tomography

    International Nuclear Information System (INIS)

    Fitz, C.R.; Harwood-Nash, D.C.; Kirks, D.R.; Kaufman, R.A.; Berger, P.E.; Kuhn, J.P.; Siegel, M.J.

    1983-01-01

    Dr. Donald Kirks has assembled this section on Practical Techniques for Pediatric Computed Tomography. The material is based on a presentation in the Special Interest session at the 25th Annual Meeting of the Society for Pediatric Radiology in New Orleans, Louisiana, USA in 1982. Meticulous attention to detail and technique is required to ensure an optimal CT examination. CT techniques specifically applicable to infants and children have not been disseminated in the radiology literature and in this respect it may rightly be observed that ''the child is not a small adult''. What follows is a ''cookbook'' prepared by seven participants and it is printed in Pediatric Radiology, in outline form, as a statement of individual preferences for pediatric CT techniques. This outline gives concise explanation of techniques and permits prompt dissemination of information. (orig.)

  11. Teleradiology for emergency cranial computed tomography

    International Nuclear Information System (INIS)

    Stranzinger, E.; Treumann, T.C.; Dreier, D.; Allgayer, B.

    2003-01-01

    Purpose: We report our experience with the teleradiologic service provided by a center hospital (CH) for emergency cranial computed tomography (CCT) in two regional hospitals (RH) during a 12-month period. The clinical and economic impact of teleradiology will be discussed as well as the acceptance by the clinicians of the regional hospitals. Material and Methods: In 2001, 213 CT-scans in 202 patients were performed and reported using teleradiology. Teleradiologic and final medical diagnosis were analysed by the medical reports. The transferral of the patients to a CH and their further treatment were checked. The referring physicians in the RH were questionnaired about the teleradiological support. Results: 18 (9%) patients had to be urgently transferred to a CH based on the CT findings in the teleradiological reports. 24 patients (11%) were transferred to a center hospital during further treatment. 80% of patients were treated in the RH. (orig.) [de

  12. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  13. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  14. Computed tomography of radioactive objects and materials

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Murphy, R.V.; Tosello, G.; Reynolds, P.W.; Romaniszyn, T.

    1990-01-01

    Computed tomography (CT) has been performed on a number of radioactive objects and materials. Several unique technical problems are associated with CT of radioactive specimens. These include general safety considerations, techniques to reduce background-radiation effects on CT images and selection criteria for the CT source to permit object penetration and to reveal accurate values of material density. In the present paper, three groups of experiments will be described, for objects with low, medium and high levels of radioactivity. CT studies on radioactive specimens will be presented. They include the following: (1) examination of individual ceramic reactor-fuel (uranium dioxide) pellets, (2) examination of fuel samples from the Three Mile Island reactor, (3) examination of a CANDU (CANada Deuterium Uranium: registered trademark) nuclear-fuel bundle which underwent a simulated loss-of-coolant accident resulting in high-temperature damage and (4) examination of a PWR nuclear-reactor fuel assembly. (orig.)

  15. System Matrix Analysis for Computed Tomography Imaging

    Science.gov (United States)

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  16. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  17. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    Nakayama, N.; Ito, Y.; Iwata, K.; Nishihara, E.; Shibayama, S.

    1984-01-01

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  18. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  19. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  20. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    Tans, J.T.J.

    1978-01-01

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  1. Computed tomography of the abnormal thymus

    International Nuclear Information System (INIS)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion

  2. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  3. Computed tomography of Rathke's cleft cyst

    International Nuclear Information System (INIS)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo.

    1986-01-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans. (author)

  4. Computed tomography of Rathke's cleft cyst

    Energy Technology Data Exchange (ETDEWEB)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo

    1986-02-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans.

  5. A computed tomography study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, H.; Kobayashi, K.; Juntendo Univ. School of Medicine, Tokyo; Ikeda, Y.; Nagao, Y.; Ogihara, R.; Kosaka, K.; Psychiatric Research Inst. of Tokyo

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease. (orig.) [de

  6. Computed Tomography findings in Fournier's gangrene

    International Nuclear Information System (INIS)

    Isusi, M.; Campo, M.; Oleaga, L.; Grande, J.; Grande, D.

    2000-01-01

    To assess the utility of computed tomography (CT) as an imaging technique in the diagnosis and determination of the extension of Fournier's gangrene (FG). We report the cases of six patients who had been clinically diagnosed as having FG, CT, enhanced by oral and intravenous contrast media, was performed in all the patients. All six patients presented soft tissue masses and gas in the scrotal region, which were also detected in the perineal region in five. In two patients, the gas extended toward anterior abdominal wall and in one of them, it also observed in anterior and posterior para renal space. The major predisposing factors were diabetes and alcoholism and the most common triggering factor was urologic disease. CT confirms the existence of FG and aids in assessing its extension and, in some cases, in identifying the underlying cause. (Author) 15 refs

  7. Minamata disease demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Matsumoto, S.C.; Okajima, T.; Inayoshi, S.; Ueno, H.

    1988-01-01

    Computed tomography was studied in the patients with Minamata disease, a methylmercury poisoning caused by the ingestion of contaminated sea foods. The characteristic changes in the acquired cases were atrophy of the visual calcarine cortex and of the cerebellar vermis and or hemisphere. Marked atrophy of the calcarine cortex produced the sac-shaped low density areas between the occipital lobes and diffuse and marked cerebellar atrophy with enlargement of the fourth ventricle and cisterns of the posterior fossa produced a shrunken image on CT. Morphometric analysis confirmed these findings. In the fetal cases, the changes on CT were slight and no definite atrophy was demonstrated in either the calcarine cortex or the cerebellum. Morphometric analysis disclosed an increase of size of the middle portions of the lateral ventricle and the third and fourth ventricles. (orig.)

  8. Computed tomography of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Megibow, A.J.; Balthazar, E.J.

    1986-01-01

    New generation CT scans combined with high-detail barium studies have now allowed radiologists to see and gain a more complete understanding of the wall and surrounding structures of the gastrointestinal tract. The editors state that their intent is to ''present in a comprehensive volume an up-to-date evaluation o the role, significance, indications, and limitations of computed tomography of the gastrointestinal tract.'' There is an initial chapter on CT scanning techniques and the use of oral contrast agents. Chapters follow on Ct of the esophagus, stomach, duodenum, small bowel, and colon. The chapters start with a description of the anatomic structures and then cover in detail common pathologic conditions that affect the organ. Indications for examinations are also included in many chapters. There are final chapters on percutaneous drainage of abscesses and fluid collections and on radiologic-patholoic correlation of some of the more common entities

  9. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  10. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka

    1994-01-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  11. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  12. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    Energy Technology Data Exchange (ETDEWEB)

    Teksam, Mehmet E-mail: mehmetteksam@yahoo.com; McKinney, Alexander; Truwit, Charles L

    2004-12-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass.

  13. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    International Nuclear Information System (INIS)

    Teksam, Mehmet; McKinney, Alexander; Truwit, Charles L.

    2004-01-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass

  14. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  15. Accelerating Magnetic Resonance Fingerprinting (MRF) using t-Blipped Simultaneous Multi-Slice (SMS) acquisition

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F.; Du, Yiping; Wald, Lawrence L.; Griswold, Mark A.; Setsompop, Kawin

    2015-01-01

    Purpose We incorporate Simultaneous Multi-Slice (SMS) acquisition into MR Fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Further, by varying the Gz blip area and/or polarity as a function of TR, the slices’ differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from Multi-band factor (MB)=2 t-Blipped SMS-MRF shows good accuracy and precision when compared to results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. Conclusions The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. PMID:26059430

  16. A multi-slice sliding cell technique for diffusion measurements in liquid metals

    Science.gov (United States)

    Zhong, Langxiang; Hu, Jinliang; Geng, Yongliang; Zhu, Chunao; Zhang, Bo

    2017-09-01

    The long capillary and shear-cell techniques are traditionally used for diffusion measurements in liquid metals. Inspired by the idea of the shear-cell method, we have built a multi-slice sliding cell device for inter-diffusion measurements in liquid metals. The device is designed based on a linear sliding movement rather than a rotational shearing as used in the traditional shear-cell method. Compared with the normal shear-cell method, the present device is a more compact setup thus easier to handle. Also, it is expected to be easier to monitor with X-rays or neutrons if used in in situ experiments. A series of benchmark time-dependent diffusion experiments in Al-Cu melts carried out with the present technique reveal that accurate diffusion constants can be achieved only after a sufficient time. For short annealing times, the initial shearing process causing convective flow dominates the measurement and leads to an increase of the measured diffusion coefficient by a factor three. The diffusion data obtained for Al-Cu liquids are consistent with the most accurate data measured by the in situ X-ray radiography method under well controlled conditions of no temperature gradient or other perturbation. High accuracy and easy handling as well as superior adaptability make the present technique suitable for diffusion studies in liquid metals.

  17. The diagnostic value of multi-slice CT on the congenital malformation of coronary sinus

    International Nuclear Information System (INIS)

    Li Wei; Ma Xiaojing; Sun Qingjun

    2012-01-01

    Objective: To investigate the application value of multi-slice spiral CT on the congenital malformation of coronary sinus. Methods: MSCT finding of 98 patients with coronary sinus malformation confirmed by surgery were retrospectively analyzed,and the cases were divided into four categories based on the Mantini theory and comparison was made between the diagnosis from ultrasound and CT. A 2 × 2 table for Chi-square test was also used for statistics analysis. Results: Among 98 patients,there were 72 patients with persistent left superior vena cava reflowed to right atria through coronary sinus, with 48 patients diagnosed by ultrasound and 72 patients by MSCT; there were 13 patients with anomalous pulmonary venous connection to coronary sinus, with 12 patients diagnosed by ultrasound and 13 patients by MSCT diagnosis; there were 10 patients with unroofed coronary sinus syndrome, with 6 patients diagnosed by ultrasound and 8 patients by MSCT, there were 2 patients with coronary sinus atresia, all diagnosed by MSCT; there were 1 patient with coronary sinus anomaly reflow to left arita. The significant difference between 2 modalities (χ 2 =22.7, P<0.01) shows that CT is superior to ultrasound. Conclusion: MSCT is much more better than ultrasound in the diagnosis of malformation of coronary sinus and it can provide reliable diagnosis prior to surgery or interventional therapy. (authors)

  18. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  19. The significance of multi-slice helical CT multiplanar reconstruction in the diagnoses of laryngeal carcinoma

    International Nuclear Information System (INIS)

    Li Lin; Luo Dehong; Zhou Chunwu; Zhao Xinming; Jiang Liming; Huang Yao; Jiang Lingxia; Li Jing; Wu Ning

    2006-01-01

    Objective: To evaluate the significance of multi-slice helical CT with multiplanar reconstruction in laryngeal carcinoma. Methods: Thirty-five patients with laryngeal carcinoma were studied by helical CT, MPR were subsequently done. The lesion extent of the axial image findings, MPR findings and the combined image findings were compared with the pathological results respectively. The data were statistically analyzed. Results: In the evaluation of the anterior commissure, the axial image findings, MPR findings and the combined image findings were 82.9%, 68.6% and 91.4% in accuracy respectively, the results were statistically different (P 0.05). The combined images were superior to the axial images and the MPR images in sensitivity, specificity and accuracy of the lesion extent. Conclusion: The axial images could show the shape, size, extension of the tumor and the lymphadenopathy, MPR images displayed the shape, size and extension roundly and directly, they were the supplement for the axial images. Axial images combined with MPR could improve the accuracy in the diagnoses of laryngeal carcinoma. (authors)

  20. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  1. The role of multi-slice CT in preoperative staging of colonic tumors

    International Nuclear Information System (INIS)

    Zhang Miao; Chen Kemin; Zhao Zehua; Ling Huawei

    2005-01-01

    Objective: To determine the accuracy of multi-slice CT pneumocolon in the staging of colonic carcinomas. Methods: Thirty-six patients, who were strongly suspected to have colonic disorders, underwent CT pneumocolon before and after intravenous injection of iodinated contrast agent. CTVE, MPR, SSD, and Raysum images were then obtained by using 4 different softwares in workstation (ADW3.1). 33 positive cases were staged preoperatively according to TNM standard. All cases were proved by surgical or colonoscopic histology. Sensitivity and accuracy of MSCT were determined for the detection of cancers, lymph nodes, and metastases. Results: MSCT pneumocolon examinations demonstrated 32 lesions, missing one case. Sensitivity and positive accuracy value for T staging were 96.97% (32/33) and 87.88% (29/33), respectively; Sensitivity and positive accuracy value for lymph node involvement were 73.91% (17/23) and 69.57% (16/23), respectively. The density of metastatic lymph node was higher than that of normal one. Five cases in M stage were all diagnosed correctly. Conclusion: MSCT pneumocolon is a better method of depicting the colorectal carcinoma. It allows for accurate staging of the colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. However the value for early T staging in colorectal carcinoma and minute metastasis of lymph nodes is limited. It is helpful to combine all the findings of lymph nodes, including the size, density, and location, to make a correct diagnosis. (authors)

  2. Value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Wang Kang; Zhao Zehua; Wang Zhi; Wang Weizhong; Xu Songsen; Zhang Miao; Liu Wenjin; Zhang Guozhen; Feng Dianxu

    2005-01-01

    Objective: To investigate the value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis. Methods: A total of 39 patients with clinically suspected acute appendicitis underwent surgery from February, 2002 to September, 2003. They were prospectively examined before surgery with routine CT scanning and MPVR reconstruction spiral CT. 31 cases of appendicitis were confirmed after appendectomy. CT scans and surgery-pathology reports were evaluated on a five-grade scale from hyperemic-edematous appendix to abscess (normal appendix: 0 grade). Results: The results of spiral CT MPVR reconstruction were compared with the surgical and pathologic findings at appendectomy, yielding an accuracy of 87.2%, sensitivity of 90.3%, specificity of 75%, positive predictive value of 93.3%, and negative predictive value of 66.7%, respectively. Results of routine CT yielded an accuracy of 38.5%, sensitivity of 38.7%, specificity of 37.5%, positive predictive value of 70.6%, and negative predictive value of 13.6%, respectively. MPVR reconstruction signs of 28 patients with acute appendicitis included enlarged appendix ( > 6 mm) (96.4%), appendicoliths (26.7%), caecal apical thickening (36.7%), periappendiceal inflammation (71.4%), and abscess (10.7%). Conclusion: The use of spiral CT MPVR reconstruction in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to a significant improvement in the preoperative diagnosis and maybe a decrease in surgical-pathologic severity of appendiceal disease. (authors)

  3. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  4. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  5. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  6. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru

    1982-01-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  7. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  8. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  9. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  11. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  12. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  13. Computed tomography apparatus with detector sensilivity correction

    International Nuclear Information System (INIS)

    Waltham, R. M.

    1984-01-01

    In a rotary fan beam computed tomography apparatus using recurrent relative displacement between the source and detectors (e.g. a deflected spot X-ray tube) for the recalibration of detectors in chain-like sequences across the detector array by successive pairwise common-path sensitivity comparisons starting from a terminal detector each sequence normally involves or more successive comparisons, and consistent but unpredictable errors are found to occur, leading to incorrect Houndsfield values in the computed image matrix. The improvement comprises locating at least one radiation transparent detector of high stability in front of the array at an intermediate point and using the output to further correct the chain-corrected detector sensitivity values. A detector comprising a plastics scintillator optically coupled to a photomultiplier is described, whose output pulses are counted during a rotational scan and compared with the mean corresponding measurement from detectors lying behind the detector, to form a sensitivity ratio. From a corresponding ratio and data derived during calibration, a measured sensitivity value for detectors is determined for each scan and is compared with the corresponding chain-corrected sensitivity value to generate a further sensitivity correction value which is then distributed among the detectors of the comparison sequence

  14. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  15. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  16. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Experimental study of quantity to be taken as patient dose in helical multi-slice CT scan

    International Nuclear Information System (INIS)

    Liu Lantao; Wei Kedao; Yue Brorong; Wang Jianchao

    2009-01-01

    Objective: To bring forward a novel quantity which is used to be taken as effective dose in helical multi - slice CT scan and to validate it by experiment. Methods: Dot chamber and pencil-chamber were used to measure the doses which were performed under axial mode and helical multi-slice mode. Then the readings of doses were compared and analyzed. Results: The dose reading from dot chamber was close to the one from pencil - chamber under axial mode. The ratio is 1.14 for the readings from dot chamber under two scan modes and is 2.88 for the readings from pencil-chamber under two scan modes. Conclusions: The dose measured from dot chamber is an effective quantity to be taken as effective dose. However it is insufficient that the CTDI and DLP be used to be taken as effective dose as the limitation of pencil-chamber in length. (authors)

  18. Significance of computed tomography in urology

    International Nuclear Information System (INIS)

    Harada, Takashi

    1981-01-01

    There are more than five years since computed tomography (CT) was first introduced in this country for practical use. However, cumulative diagnostic experiences in urology have not been discussed thoroughly yet. In the Department of Urology of Kansai Medical University over 120 times CT diagnosis were attempted past three years and the instrument employed during this period has been alternative from the first generation type (ACTA 150) to the third one (CT-3W) this year as to technical advance. These cases are 70 of pelvic lesions and retroperitoneal surveys are made in the rests. As a results, detection of space occupying mass in kidney, adrenal and their surroundings was comparatively easy to deliver by this method, but there are several pitfalls to come misunderstanding in diagnosis of pelvic organs. It seems to be difficult to obtain certain result on closely packed viscera with tightly adhered connective tissue in tiny space. However, these difficulties will be solved by bladder insufflation with olive oil, for instance, and scanning in prone position. Contrast enhancement by injection of dye also give more definite results in genitourinary tract assessment. Moreover, there are much benefit in diagnosis of renal parenchymal change including lacerating renal trauma unable to be differentiated conventional method. Bolus injection of contrast material also allows to calculate CT values obtained from ROI on tomography and enables to fit the value to time-activity curve likewise scintillation scanning. In forthcomming day, new device in this field including emission-CT, NMR-CT and others will open new sight for ideal diagnostic facility in urology. (author)

  19. Computed tomography and radioprotection: Knowing and acting

    International Nuclear Information System (INIS)

    Ducou Le Pointe, H.

    2013-01-01

    Exposure of the population to ionizing radiation for medical purposes is increasing throughout the world. In the United States of America, this exposure (3 mSv) has reached, even exceeded, exposure from natural sources. In France, the report of the French Institute for Radiological Protection and Nuclear Safety (IRSN) on exposure of the French population to ionizing radiation in 2007, based on the 74.6 million medical diagnostic procedures, estimates the mean individual effective dose to be 1.3 mSv. This value is much lower than the value in the United States but has progressed in 5 years by 62.5%. Computed tomography accounts for 10.1% of the procedures and 58% of the collective effective dose. This is why computed tomography is receiving very special attention from all those involved in radioprotection. It must be remembered, nevertheless, that we are well within the low dose range (effective dose less than 100 mSv), and indeed, in the large majority of CT examinations exposure values are lower than 15 mSv. The biological effects of low doses are still a matter of debate. First of all, it has not been possible to demonstrate the risk of cancer due to this level of exposure, neither on the survivors of the atomic bombs in Japan nor on workers in the nuclear industry in the United Kingdom. The year 2012 marked a change; for the first time, epidemiology took over from statistical studies. Despite the low risk demonstrated, reserves concerning methodology, and waiting for further European epidemiological studies underway, we must continue to act to encourage radiological protection. Before considering the action to take and without under-estimating the risks, it is important to remember that a computed tomography investigation is conducted in patients, and not in individuals in good health. Acting to provide patients with protection from radiation means involving all those concerned with justifying it, with substituting it, and with optimising it. For some years

  20. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  1. Computed Tomography of pediatric head trauma

    International Nuclear Information System (INIS)

    Shin, Kyoung Hee; Cho, Bum Shin; Hahm, Chang Kok

    1982-01-01

    The development of Computed Tomography (CT) scanning has revolutionized the role of radiology in the management of the pediatric head trauma. The procedure is safe and can be repeated to reasses a changing neurologic picture, thereby correlation the clinical and pathologic changes. This study included evaluation of CT of 178 infants and children with head trauma during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. 1. Age distribution of the total 178 pediatric patients was ranging from one month to 16 years. The pediatric patient population was comprised of 128 males and 50 females, and its male to female ratio was about 2.5 : 1. The incidence of age occurring in 3 to 6 years was 38.2% and 7 to 10 years was 29.2%. Therefore the distribution of age between 3 to 6 years and 7 to 10 years was occurred in two-thirds of all pediatric patients. 2. Of all cases of injuries, traffic accidents were 60.1% and falls were 34.8%. 3. Skull fracture were roentgenographically detected in 61 (34.3%). However, the incidence of fractures in pretoddler group (0-2 years) was 61.1% and 7 to 10 years was 37.8%, 3 to 6 years was 36.8%. More common site of skull fracture was occipital bone,next partietal bone. 4. 54.8% of pediatric head trauma due to a full had a skull fracture, as did 25.2 % of those who were injured in traffic accident. 5. Cerebral Computed Tomography (CT) of the total 178 pediatric patients were revealed as following study.: Normal was 74.2%, epidural hematoma was 8.9%, subdural hematoma was 5.1%, cerebral contusion was 4.5%, intracerebral hematoma was 2.2% etc. 6. Of 25 cases of the epidural and subdural hematoma, supratentorial area was 15 cases, infratentorial area was 10 cases. 7. Most of the epidural hematoma was demonstrated a clear mental state. 8. However, intracerebral hematoma and cerebral contusion were occurred almost impairment of mental state

  2. Assessment of calcium scoring performance in cardiac computed tomography

    International Nuclear Information System (INIS)

    Ulzheimer, Stefan; Kalender, Willi A.

    2003-01-01

    Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The purpose of this work was to qualitatively and quantitatively evaluate the performance for EBT and MSCT for the task of coronary artery calcium imaging as a function of acquisition protocol, heart rate, spiral reconstruction algorithm (where applicable) and calcium scoring method. A cardiac CT semi-anthropomorphic phantom was designed and manufactured for the investigation of all relevant image quality parameters in cardiac CT. This phantom includes various test objects, some of which can be moved within the anthropomorphic phantom in a manner that mimics realistic heart motion. These tools were used to qualitatively and quantitatively demonstrate the accuracy of coronary calcium imaging using typical protocols for an electron beam (Evolution C-150XP, Imatron, South San Francisco, Calif.) and a 0.5-s four-slice spiral CT scanner (Sensation 4, Siemens, Erlangen, Germany). A special focus was put on the method of quantifying coronary calcium, and three scoring systems were evaluated (Agatston, volume, and mass scoring). Good reproducibility in coronary calcium scoring is always the result of a combination of high temporal and spatial resolution; consequently, thin-slice protocols in combination with retrospective gating on MSCT scanners yielded the best results. The Agatston score was found to be the least reproducible scoring method. The hydroxyapatite mass, being better reproducible and comparable on different scanners and being a physical quantitative measure, appears to be the method of choice for future clinical studies. The hydroxyapatite mass is highly correlated to the Agatston score. The introduced phantoms can be used to quantitatively assess the

  3. Evidence of neurofibromatosis type 1 in a multi-morbid Inca child mummy: A paleoradiological investigation using computed tomography.

    Science.gov (United States)

    Panzer, Stephanie; Wittig, Holger; Zesch, Stephanie; Rosendahl, Wilfried; Blache, Sandra; Müller-Gerbl, Magdalena; Hotz, Gerhard

    2017-01-01

    In this study, an Inca bundle was examined using computed tomography (CT). The primary aim was to determine the preservation status of bony and soft tissues, the sex, the age at the time of death, possible indicators for disease or even the cause of death, as well as the kind of mummification. A secondary aim was to obtain a brief overview of the wrapping in order to gain additional information on the cultural background. The bundle belongs to the Museum of Cultures in Basel, Switzerland, and was bought in Munich, Germany, in 1921. Radiocarbon dating of the superficial textile yielded a calibrated age between 1480 and 1650 AD. The mummy was investigated using multi-slice CT with slice thickness of 0.75 mm and 110 kilovolt. For standardized assessment of soft tissue preservation, a recently developed checklist was applied. CT revealed the mummy of a seven to nine year old boy with superior preservation of bony and soft tissues allowing detailed assessment. Indicators of neurofibromatosis type 1 (paravertebral and cutaneous neurofibromas, a breast neurofibroma, sphenoid wing dysplasia), Chagas disease (dilatation of the esophagus, stomach, rectum, and large amounts of feces), and lung infection (pleural adherence, calcifications), probably due to tuberculosis, were found. Furthermore, signs of peri-mortem violence (transection of the chest and a defect in the abdominal wall) were detected. CT images revealed a carefully performed wrapping. CT examination of the Inca bundle proved to be an important non-destructive examination method. Standardized assessment, especially of the soft tissue structures, allowed for diagnoses of several diseases, indicating a multi-morbid child at the time of death. The careful wrapping pointed to a ceremonial burial. Within the cultural background, the signs of fatal violence were discussed as a possible result of war, murder, accident, or human sacrifice.

  4. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  5. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  6. Evidence of neurofibromatosis type 1 in a multi-morbid Inca child mummy: A paleoradiological investigation using computed tomography.

    Directory of Open Access Journals (Sweden)

    Stephanie Panzer

    Full Text Available In this study, an Inca bundle was examined using computed tomography (CT. The primary aim was to determine the preservation status of bony and soft tissues, the sex, the age at the time of death, possible indicators for disease or even the cause of death, as well as the kind of mummification. A secondary aim was to obtain a brief overview of the wrapping in order to gain additional information on the cultural background.The bundle belongs to the Museum of Cultures in Basel, Switzerland, and was bought in Munich, Germany, in 1921. Radiocarbon dating of the superficial textile yielded a calibrated age between 1480 and 1650 AD. The mummy was investigated using multi-slice CT with slice thickness of 0.75 mm and 110 kilovolt. For standardized assessment of soft tissue preservation, a recently developed checklist was applied.CT revealed the mummy of a seven to nine year old boy with superior preservation of bony and soft tissues allowing detailed assessment. Indicators of neurofibromatosis type 1 (paravertebral and cutaneous neurofibromas, a breast neurofibroma, sphenoid wing dysplasia, Chagas disease (dilatation of the esophagus, stomach, rectum, and large amounts of feces, and lung infection (pleural adherence, calcifications, probably due to tuberculosis, were found. Furthermore, signs of peri-mortem violence (transection of the chest and a defect in the abdominal wall were detected. CT images revealed a carefully performed wrapping.CT examination of the Inca bundle proved to be an important non-destructive examination method. Standardized assessment, especially of the soft tissue structures, allowed for diagnoses of several diseases, indicating a multi-morbid child at the time of death. The careful wrapping pointed to a ceremonial burial. Within the cultural background, the signs of fatal violence were discussed as a possible result of war, murder, accident, or human sacrifice.

  7. Evaluation of the nutcracker syndrome using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Fan Yanqing; Han Ping; Zhou Chengkai; Zhao Long; Wu Hongying; Yu Qun; Liu Yonghua

    2007-01-01

    Objective: To evaluate the ability of multi-slice spiral CT (MSCT) in diagnosing nutcracker syndrome(NCS). Methods: MSCT angiography (MSCTA) or contrast enhanced CT data of 16 patients clinically diagnosed as NCS( patient group) and 80 subjects with nomal kidneys and renal vessels (control group ) were retrospectively reviewed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The angle (a) between SMA and the abdominal aorta (AA), the distance (d) between SMA and AA at the level of LRV passing through, the cross areas of LRV through the angle (s1) and at the largest diameter near the renal hilar (s2) were measured and the ratio(q) of s2 to sl was calculated. Results: All LRVs were compressed and showed dilated, 7 of them with the genesial gland vein enlargement. The causes of the LRV narrowing and obstruction were small angle (a) in 14 patients and abnormal path of LRV posterior to AA in 2 cases. The value of a,d,s1,s2 and q in the patient group and the control group were: (21±4) degree, (0.53±0.11) cm, (0.28±0.06) cm 2 , (1.42±0.48) cm 2 , 5.26 and (52±24) degree, (1.39±0.70) cm, (0.81±0.32) cm 2 , (1.21±0.35) cm 2 , 1.52, respectively. The differences were significant between the two groups (P< 0.05). Conclusion: The appearance and its path of the LRV could be well delineated on the MSCT, allowing a accurate evaluation of the LRV narrowing non-invasively. (authors)

  8. Value of multi-slice CT in the classification diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Yi; Zeng Mengsu; Ling Zhiqing; Rao Shengxiang; Liu Yalan

    2008-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) classification in the assessment of the hilar cholangiocarcinoma resectability. Methods: Thirty patients with surgically and histopathologically proved hilar cholangiocarcinomas who underwent preoperative MSCT and were diagnosed correctly were included in present study. Transverse images and reconstructed MPR images were reviewed for Bismuth-Corlette classification and morphological classification of hilar cholangiocarcinoma. Then MSCT classification was compared with findings of surgery and histopathology. Curative resectabilty of different types according to Bismuth-Corlette classification and morphological classification were analyzed with chi-square test. Results: In 30 cases, the numbers of Type I, II, IIIa, IIIb and IV according to Bismuth-Corlette classification were 1, 3, 4, 5 and 17. Seventeen patients underwent curative resections, among which 1, 2, 1, 4 and 9 belonged to Type I, II, IIIa, IIIb and IV respectively. However, there was no significant difference in curative resectability among different types of Bismuth-Corlette classification (χ 2 = 0.9875, P>0.05). In present study, the accuracy of MSCT in Bismuth-Corlette classification reached 86.7% (26/30). The numbers of periductal infiltrating, mass forming and intraductal growing type were 13, 13 and 4, while 6, 8 and 3 cases of each type underwent curative resections. There was no significant difference in curative resectability among different types of morphological classification (χ 2 =1.2583, P>0.05). The accuracy of MSCT in morphological classification was 100% (30/30) in this study group. Conclusion: MSCT can make accurate diagnosis of Bismuth-Corlette classification and morphological classification, which is helpful in preoperative respectability assessment of hilar cholangiocarcinoma. (authors)

  9. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  10. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  11. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  12. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  13. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  14. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  15. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  16. Kimura's disease: imaging patterns on computed tomography

    International Nuclear Information System (INIS)

    Gopinathan, Anil; Tan, T.Y.

    2009-01-01

    Aim: To define the role of computed tomography (CT) in identifying and classifying the imaging patterns of diagnostic value in Kimura's disease of the head and neck. Methods: A retrospective study was undertaken comprising 13 patients with histopathological evidence of Kimura's disease. The patients' clinical and pathological records were reviewed against a detailed analysis of their CT images performed from the base of the skull to the arch of the aorta. Results: Both well-defined, nodular masses, as well as ill-defined plaque-like infiltrative masses were seen in the subcutaneous tissue of the head and neck region. All patients had lesions adjacent to the major salivary glands. The parotid gland was affected in 10 of the 13 cases and the submandibular gland was affected in the rest. Contrast enhancement was variable. More than half of the cases had associated lymphadenopathy. Some of them showed atrophy of the skin and subcutaneous fat overlying the subcutaneous masses. Blood eosinophilia was a consistent feature in all the cases. Conclusion: The patterns of distribution, morphology, and enhancement of the lesions in Kimura's disease that can be demonstrated at CT, enables a confident, non-invasive diagnosis of this condition, in an appropriate clinical context.

  17. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  18. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  19. Measurements of computed tomography radiation scatter

    International Nuclear Information System (INIS)

    Van Every, B.; Petty, R.J.

    1992-01-01

    This paper describes the measurement of scattered radiation from a computed tomography (CT) scanner in a clinical situation and compares the results with those obtained from a CT performance phantom and with data obtained from CT manufacturers. The results are presented as iso-dose contours. There are significant differences between the data obtained and that supplied by manufacturers, both in the shape of the iso-dose contours and in the nominal values. The observed scatter in a clinical situation (for an abdominal scan) varied between 3% and 430% of the manufacturers' stated values, with a marked reduction in scatter noted a the head and feet of the patient. These differences appear to be due to the fact that manufacturers use CT phantoms to obtain scatter data and these phantoms do not provide the same scatter absorption geometry as patients. CT scatter was observed to increase as scan field size and slice thickness increased, whilst there was little change in scatter with changes in gantry tilt and table slew. Using the iso-dose contours, the orientation of the CT scanner can be optimised with regard to the location and shielding requirements of doors and windows. Additionally, the positioning of staff who must remain in the room during scanning can be optimised to minimise their exposure. It is estimated that the data presented allows for realistic radiation protection assessments to be made. 13 refs., 5 tabs., 6 figs

  20. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  1. Computed tomography findings in pancreas divisum

    International Nuclear Information System (INIS)

    Lindstroem, E.; Ihse, I.

    1989-01-01

    In 29 patients with abdominal pain the diagnosis of pancreas divisum (PD) was verified by endoscopic retrograde pancreatography (EPR) via both the major and the minor papilla. Computed tomography (CT) was done in all patients to evaluate contour, volume, antero-posterior diameters and attenuation values of the gland in comparison with a normal reference series. Also, the validity of the CT grading of pancreatitis was assessed in comparison with ERP grading. Patients with PD had an increased cranio-caudal diameter of the pancreatic head (p<0.001). Further, the main pancreatic duct was visualized more often in patients with PD (p<0.01), who also had an increasing frequency of pancreatic calcifications (p<0.05). Otherwise there were no differences compared with the normal series. The observed reduction in the volume of the gland in patients with marked pancreatitis at ERP seemingly reflected the severity of inflammation. No cleavage between the dorsal and ventral anlage was identified. CT was found to be too unspecific to be of any use in grading of pancreatitis. In conclusion, CT findings in patients with PD are sparse, unspecific and preferably a reflection of pancreatitis, if present. ERP remains the ''gold standard'' for the diagnosis. (orig.)

  2. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  3. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  4. High resolution computed tomography of positron emitters

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Cahoon, J.L.; Huesman, R.H.; Jackson, H.G.

    1976-10-01

    High resolution computed transaxial radionuclide tomography has been performed on phantoms containing positron-emitting isotopes. The imaging system consisted of two opposing groups of eight NaI(Tl) crystals 8 mm x 30 mm x 50 mm deep and the phantoms were rotated to measure coincident events along 8960 projection integrals as they would be measured by a 280-crystal ring system now under construction. The spatial resolution in the reconstructed images is 7.5 mm FWHM at the center of the ring and approximately 11 mm FWHM at a radius of 10 cm. We present measurements of imaging and background rates under various operating conditions. Based on these measurements, the full 280-crystal system will image 10,000 events per sec with 400 μCi in a section 1 cm thick and 20 cm in diameter. We show that 1.5 million events are sufficient to reliably image 3.5-mm hot spots with 14-mm center-to-center spacing and isolated 9-mm diameter cold spots in phantoms 15 to 20 cm in diameter

  5. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    Dibianca, F.A.; Dallapiazza, D.G.

    1981-01-01

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  6. Computed tomography shielding methods: a literature review.

    Science.gov (United States)

    Curtis, Jessica Ryann

    2010-01-01

    To investigate available shielding methods in an effort to further awareness and understanding of existing preventive measures related to patient exposure in computed tomography (CT) scanning. Searches were conducted to locate literature discussing the effectiveness of commercially available shields. Literature containing information regarding breast, gonad, eye and thyroid shielding was identified. Because of rapidly advancing technology, the selection of articles was limited to those published within the past 5 years. The selected studies were examined using the following topics as guidelines: the effectiveness of the shield (percentage of dose reduction), the shield's effect on image quality, arguments for or against its use (including practicality) and overall recommendation for its use in clinical practice. Only a limited number of studies have been performed on the use of shields for the eyes, thyroid and gonads, but the evidence shows an overall benefit to their use. Breast shielding has been the most studied shielding method, with consistent agreement throughout the literature on its effectiveness at reducing radiation dose. The effect of shielding on image quality was not remarkable in a majority of studies. Although it is noted that more studies need to be conducted regarding the impact on image quality, the currently published literature stresses the importance of shielding in reducing dose. Commercially available shields for the breast, thyroid, eyes and gonads should be implemented in clinical practice. Further research is needed to ascertain the prevalence of shielding in the clinical setting.

  7. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  8. Cranial computed tomography in infantile spasms

    International Nuclear Information System (INIS)

    Howitz, P.; Neergaard, K.; Pedersen, H.

    1990-01-01

    Out of 109 children with infantile spasms (IS), prospectively tested during the years 1976 to 1979 in Denmark, 52 children were examined by cranial computed tomography (CT). The classification of IS into cryptogenic (CR), symptomatic (SY) and doubtful (DO) was done clinically without considering the CT-finding. Sixty per cent of the scannings were abnormal. Only 6/30 (20%) of the children in ACTH treatment were found to develop cerebral atrophy which means that this finding is not an obligatory side-effect of ACTH treatment of children with IS. Normal CT-findings were found in 50% of the CR and 50% of the SY + DO-groups, and could not be used as a prognostic tool for estimating the mental development. This was also the case for children with cerebral atrophy. Abnormal CT-findings (minus atrophy) were highly correlated to the group with clinical symptoms and indicate an extremely unsatisfying long-term mental prognosis. CT-scanning is a valuable tool for the examination of clearing children with infantile spasms. (authors)

  9. Evaluation of pulmonary congestion by computed tomography

    International Nuclear Information System (INIS)

    Morooka, Nobuhiro; Yamamoto, Hironori; Yoshida, Hideo; Watanabe, Shigeru; Nakamura, Mamoru

    1980-01-01

    Pulmonary congestion and pulmonary water distribution of lung fields were evaluated by computed tomography (CT) in 31 patients with congestive heart failure and 19 normal subjects in the supine position. In normal subjects, no difference was noted in the CT value between levels of intercostal spaces as well as between right and left lung fields. CT values were greater in posterior lung fields than in anterior lung fields. A significant increase of CT values at both anterior and posterior lung fields was shown in patients with congestive heart failure compared to normal subjects. In congestive heart failure, pulmonary CT values were correlated with various clinical parameters in the order of chest X-ray findings, NYHA functional classification, venous pressure, right heart catheter findings and circulation time. CT values were decreased with the improvement of parameters by medical treatment. Thus, the increase of pulmonary CT values in patients with congestive heart failure indicated the increase of pulmonary blood content and pulmonary tissue edema in a unit volume. This method was particularly useful for the evaluation of pulmonary congestion and pulmonary water distribution. (author)

  10. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Grangeat, P.

    2003-01-01

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  11. Computed tomography of lacrimal fossa tumors

    International Nuclear Information System (INIS)

    Park, Chan Sup; Kim, Young Goo; Chang, Kee Hyun

    1985-01-01

    The lacrimal fossa can be involved by a wide spectrum of orbital pathology. The correct diagnosis is important to avoid unnecessary procedure and to do appropriate management. 14 patients with mass lesions in the lacrimal fossa were evaluated with computed tomography (CT) and clinical findings. The results were as follows: 1. Final diagnosis of 14 cases with lacrimal fossa tumors was pleomorphic adenoma in 3 cases, adenoid cystic carcinoma in 1 case, pseudotumor in 5 cases, lymphoma in 2 cases, neurofibroma in 1 case, chloroma in 1 case and metastatic adenocarcinoma in 1 case. 2. The duration of symptoms of pleomorphic adenoma was more than 1 year and characteristic CT findings were globular masses with pressure erosion of the adjacent bone. Patient with adenoid cystic carcinoma had a short history of symptoms. CT showed a fusiform mass but intracranial extension with frank destruction of sphenoid bone. 3. Patients with pseudotumor and lymphoma had symptoms for less than 1 year. The CT findings were ill-defined infiltrative patterns with scleral thickening and the differential diagnosis of them was difficult. 4. The margins of neurofibroma and chloroma were well defined while that of the metastic adenocarcinoma was ill-defined. 5. The degree and the extent of the contrast enhancement gave no benefit in the differential diagnosis of each disease entities and even of the benign and malignant lesions

  12. Computed tomography in acute ischemic stroke

    International Nuclear Information System (INIS)

    Loevblad, Karl-Olof; Baird, Alison E.

    2010-01-01

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  13. Computed tomography of the breast cancer

    International Nuclear Information System (INIS)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu

    1985-01-01

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease

  14. Computed tomography of the breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu [Hallym University Medical Center, Seoul (Korea, Republic of)

    1985-12-15

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease.

  15. 16 multi-slice CT three-dimensional and multiplanar reconstruction for evaluation of pediatric congenital scoliosis

    International Nuclear Information System (INIS)

    Peng Yun; Zhang Ningning; Zhang Xuejun; Sun Guoqiang; Zeng Jinjin

    2006-01-01

    Objective: Our study is to use of 16 MSCT three-dimensional images and multiplanar reconstruction images in the preoperative investigation of patients with congenital scoliosis, to study its technical advantage and work out surgical plan. Methods: Twenty-seven pediatric patients with congenital scoliosis processing between April to October 2004 were reviewed, including 13 boys and 14 girls. X-ray plain film and sixteen multi-slice CT examination on curved/standard multiplanar reconstruction and three- dimensional computed tomographic imaging may offer, many potential advantages for defining congenital spine anomalies liable to cause progression of scoliosis, including visualization of the deformity in any plane, from any angle, with the overlying structures subtracted. Results: Ten patients had segmentation defects, 6 patients underwent formation defects, 11 patients had complex, unclassifiable anomalies. The patients of rib deformity were found in 15 patients, the most prominent part of the rib cage deformity was at the same level as the most rotated vertebra in 7 patients; 8 patients had vertebral anomalies accompanied with diastematomyelie, including 6 patients with uncompleted or completed bony spur. In 19 of 27 cases, the muhiplanar reconstruction and three-dimensional images allowed identification of unrecognized malformations and completely evaluated the degree of scoliosis, during conventional X-ray images and axial CT images, including volume 3D imaging evaluated approximately classification and modality of complex anomalies in 11 cases, which were unclassifiable malformation in 7 cases and unsegmented bar with contralateral hemivertebrae; 4 children had segmentation defects revealed unilateral unsegmented bar (3 cases) and bilateral block vertebra (1 case) in volume 3D reconstruction images; 2 children were found occultation hemivertebrae which were not been discovered during conventional X-ray images and axial CT images; and 2 children were revaluated

  16. Computer stress study of bone with computed tomography

    International Nuclear Information System (INIS)

    Linden, M.J.; Marom, S.A.; Linden, C.N.

    1986-01-01

    A computer processing tool has been developed which, together with a finite element program, determines the stress-deformation pattern in a long bone, utilizing Computed Tomography (CT) data files for the geometry and radiographic density information. The geometry, together with mechanical properties and boundary conditions: loads and displacements, comprise the input of the Finite element (FE) computer program. The output of the program is the stresses and deformations in the bone. The processor is capable of developing an accurate three-dimensional finite element model from a scanned human long bone due to the CT high pixel resolution and the local mechanical properties determined from the radiographic densities of the scanned bone. The processor, together with the finite element program, serves first as an analysis tool towards improved understanding of bone function and remodelling. In this first stage, actual long bones may be scanned and analyzed under applied loads and displacements, determined from existing gait analyses. The stress-deformation patterns thus obtained may be used for studying the biomechanical behavior of particular long bones such as bones with implants and with osteoporosis. As a second stage, this processor may serve as a diagnostic tool for analyzing the biomechanical response of a specific patient's long long bone under applied loading by utilizing a CT data file of the specific bone as an input to the processor with the FE program

  17. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  18. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  19. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  20. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  1. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  2. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  3. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    Kovac, M.; Nowak, M.; Kaufels, N.; Tambur, Z.

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  4. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Bas, Ahmet; Simsek, Osman; Kandemirli, Sedat Giray; Rafiee, Babak; Gulsen, Fatih; Numan, Furuzan

    2015-01-01

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  5. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  6. Short-term Reproducibility of Computed Tomography-based Lung Density Measurements in Alpha-1 Antitrypsin Deficiency and Smokers with Emphysema

    International Nuclear Information System (INIS)

    Shaker, S.B.; Dirksen, A.; Laursen, L.C.; Maltbaek, N.; Christensen, L.; Sander, U.; Seersholm, N.; Skovgaard, L.T.; Nielsen, L.; Kok-Jensen, A.

    2004-01-01

    Purpose: To study the short-term reproducibility of lung density measurements by multi-slice computed tomography (CT) using three different radiation doses and three reconstruction algorithms. Material and Methods: Twenty-five patients with smoker's emphysema and 25 patients with 1-antitrypsin deficiency underwent 3 scans at 2-week intervals. Low-dose protocol was applied, and images were reconstructed with bone, detail, and soft algorithms. Total lung volume (TLV), 15th percentile density (PD-15), and relative area at -910 Hounsfield units (RA-910) were obtained from the images using Pulmo-CMS software. Reproducibility of PD-15 and RA-910 and the influence of radiation dose, reconstruction algorithm, and type of emphysema were then analysed. Results: The overall coefficient of variation of volume adjusted PD-15 for all combinations of radiation dose and reconstruction algorithm was 3.7%. The overall standard deviation of volume-adjusted RA-910 was 1.7% (corresponding to a coefficient of variation of 6.8%). Radiation dose, reconstruction algorithm, and type of emphysema had no significant influence on the reproducibility of PD-15 and RA-910. However, bone algorithm and very low radiation dose result in overestimation of the extent of emphysema. Conclusion: Lung density measurement by CT is a sensitive marker for quantitating both subtypes of emphysema. A CT-protocol with radiation dose down to 16 mAs and soft or detail reconstruction algorithm is recommended

  7. Temporomandibular joint assessment in patients with articular disc displacement by way of computed tomography - radiological parameters of shape, size and location of mandibular heads

    Directory of Open Access Journals (Sweden)

    Szabelska Anna

    2015-09-01

    Full Text Available Conventional and modern methods of radiological imaging are often used in the diagnosis of temporomandibular joint disorders, and the CT technique is particularly characterized by an excellent visualization of bony structures. The aim of the study was to show the importance and role of CT in the evaluation of TMJ bone structures in both patients with articular disc displacement and in a group of healthy subjects. Both study groups were assessed with the use of the transverse plane. Herein, multi-slice spiral computed tomography was performed in 47 subjects. These individuals were qualified for CT by way of magnetic resonance imaging, due to their being diagnosed with a displacement of their temporomandibular joint disc. The product of our study is presented as a set of tables. These are comparisons of radiological parameters based on the shape, size and location of the mandibular head, in the examined patients, in a control group, and with regard to sex. The results of our work indicate that CT can be successfully used in the imaging of TMJ bone structures, specifically, the condylar process of the mandibular head and the joint socket. However, statistically significant differences of the utilized parameters between patients with articular disc displacement and controls, warrant further analysis of this issue.

  8. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  9. Attainment of dosimetric pediatrics grandeur to computed tomography examinations of the abdomen

    International Nuclear Information System (INIS)

    Jormada, Tiago S.

    2013-01-01

    Currently, 10% of all computerized tomography exams (CT) are made in pediatric patients. In developed countries, the practice of obtaining the dosimetric quantities (weighted index dose C w , index air kerma volumetric C vol product kerma-length P KL , CT ) and effective dose (E) in pediatric CT scans is common. In Brazil, data like these are practically nonexistent. The goal of this work is to obtain the dosimetric quantities and the dose effective in pediatric CT scans, and study its application in the optimization process. The study took place in a thermographs' Toshiba Asteion Single-Slice and a GE Brightsped's multi-slice where measurements were made with type pencil ionization chamber and a trunk's phantom of PMMA with diameter of 16 cm. In single-slice CT scanner, the results obtained for the C vol , P KL , CT and E were 18.73 mGy, 15.61 mGy and 6.87 mSv mGy.cm 343.51, respectively, whereas in multi-slice CT scanner the results were 18.81 mGy, 20.07 mGy, 441.64 mGy.cm and 8,83 mSv. There was no significant difference between the values of C w obtained already in the values of the Cvol, P KL , CT and E dose the differences between the results were quite significant. Comparing the C w and P KL , CT and with the values recommended by UCRP 87 (25 mGy for C vol and 360 mGy.cm for P KL , CT in pediatric CT scans of the abdomen), the two scanners were below reference levels for C w and not require an start on process of optimization. (author)

  10. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  11. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  12. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  13. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  14. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  15. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  16. Computed tomography in Duchenne type muscular dystrophy

    International Nuclear Information System (INIS)

    Kawai, Mitsuru; Kunimoto, Masanari; Motoyoshi, Yasufumi; Kuwata, Takashi; Nakano, Imaharu

    1985-01-01

    The computed tomography (CT) scan was performed on 91 Duchenne type muscular dystrophy (DMD) patients on the following four levels; (1) at the level of L3 vertebra, (2) 2-3cm above the symphysis pubica, (3) midposition of the thigh, (4) largest-diameter section of the lower leg. The CT of muscles common to most of the DMD patients were as follows: 1. Muscle atrophy: Muscle atrophy was shown as a reduction in the cross-sectional area of the muscles. Very mild muscle atrophy could be detected either by the clearly identified muscle border or by scattered low-density areas of so-called ''moth-eaten'' appearance within muscles. 2. Fat infiltration: The decrease in radio-density of muscles was interpreted as infiltration of fatty tissue. This type of density change was further classified into diffuse, streaked, cobblestone and salt-and-pepper patterns according to the spacial distribution of low-density areas. 3. Selectivity pattern: As the chronological sequence of DMD muscle degeneration is usually different among individual muscles, it may be seen, in some stages, that some of the synergistic muscles are still only slightly involved, while the others are quite severely atrophied with evident fat infiltration. In certain stages of the disease, most of the patients show relative preservation of particular muscles although they assumed a rounded shape. The most resistent muscle was musculus gracilis, followed by the musculus sartorius, musculus semitendinosus (and/or musculus semimembranosus) in that order. According to the severity of the CT changes, 86 of the 91 patients were classed into five stages from A1 to A5. Morphological stages (A1-A5) were well correlated to the functional disability stages by Ueda with a correlation factor of r=0.88. (J.P.N.)

  17. Characterization of HPGe detectors using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hedman, A., E-mail: Angelica.Hedman@foi.se [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Bahar Gogani, J.; Granström, M. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Johansson, L.; Andersson, J.S. [Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Ramebäck, H. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-41296 Göteborg (Sweden)

    2015-06-11

    Computed Tomography (CT) high-resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38±0.07) mm for the n-type detector and by (0.40±0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (<5 cm). In the energy range of 40–700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9–2.9% for the n-type detector and 0.3–2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40–700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2–7.1% for the n-type detector and 0.2–1.0% for the p-type detector, i.e. the detector efficiency is overestimated using data available by the manufacturer.

  18. Evaluation of computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Yoo, Seon Young; Lee, Young Sik; Suh, Jeong Soo; Rhee, Chung Sik; Kim, Hee Seup

    1983-01-01

    Prior to the introduction of computed tomography, the clinical and radiological diagnosis of the intraventricular hemorrhage in living patients was difficult. C.T. scanning is an invaluable investigation providing the rapid and noninvasive diagnosis of intracerebral and intraventricular hemorrhage. It reliably demonstrates the presence and distribution of fresh blood within the ventricular system. C.T. is also useful as a surgical guidance and in the evaluation of fate of the hematoma by easily performable follow-up studies. We reviewed 31 cases of intraventricular hemorrhage in C.T. in the department of radiology of Ewha Womans University Hospital during the period from August, 1982 to August, 1983. The results were as follows: 1. The most patients were encountered in the 5th decade and the male to female ratio was 1.2 : 1. 2. Hypertension was the main cause of the intraventricular hemorrhage; 18 out of 31 patients. Remaining 13 patients were caused by hypoxia, aneurysm, Moya Moya disease, coagulation defect, trauma and undetermined etiology. 3. 18 out of 31 patients showed hemorrhage in the lateral ventricles only and all ventricles in 10 patients. 4. 28 out of 31 patients showed associated with intracranial hematoma; Those were intracerebral hematomas in 16 patients, intracerebral hematoma with subarachnoid hemorrhage in 4 patients and extracerebral hematoma in 2 patients. 5. Outcome was assessed using the Glasgow scale. According to them, the total mortality rates was 54.8%, however, 32.3% of patients returned to normal or minor disability. Patients, who had hypertension and marked degree of hemorrhage in the ventricular systems had a poor outcome. Patients with only ventricular hemorrhage had better outcome than associated intracranial hematoma. 6. 16 out of 31 patients were treated by surgical methods and 15 out of 31 patients by conservative methods. 75% of patients were died in conservative treatment. 7. Conclusively, causes, degree of intraventricular

  19. Measurement of kidney by computed tomography

    International Nuclear Information System (INIS)

    Hamada, Tatsumi; Nakagawa, Kenichi; Tamura, Kenji; Yoshida, Akio; Fujii, Koichi

    1983-01-01

    Several measurements of normal kidney in vivo were obtained from computed tomography and were correlated with age, sex and body dimensions. Forty four males and 21 females without a history of renal disease were studied. 1. Angle between renal coronal section and body frontal (degree): The mean value (+- SD) of the angle was 44.0 +- 11.1 for right kidney and 42.3 +- 11.2 for left, with a low correlation coefficient. The angle had no significant correlation with age nor sex. 2. The largest width of kidney (cm): The mean value of the width was 4.6 +- 0.6 for male right kidney, 5.1 +- 0.6 for male left, 4.6 +- 0.7 for female right and 4.7 +- 1.0 for female left. The values correlated with age under 40 positively and over 40 negatively. 3. Renal volume (cm 3 ): Renal volume was calculated by adding together the area measurements obtained from successive 1 cm thick scans, excluding renal sinus. The mean volume was 107 +- 27 for male right kidney, 114 +- 24 for male left, 101 +- 33 for female right and 111 +- 41 for female left. The correlation coefficient of right versus left renal volume was significantly high. Total renal volume, i. e. left + right renal volume, had significant negative correlation with age over 40. 4. CT numbers of kidney: Average value of right kidney was 31.4 +- 6.0 and that of left was 30.7 +- 5.9. Though the correlation coefficient between right and left was nearly 1, no significant correlation was found with other values. (author)

  20. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de