  1. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  2. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  3. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  4. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  5. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  6. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  7. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  8. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  9. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  10. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

    International Nuclear Information System (INIS)

    Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon

    2009-01-01

    Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.

  11. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  12. Multi-detector CT coronary angiographic findings of coronary-to-pulmonary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Seok; Park, Eun Ah; Lim, Ji Yeon; Lee, Whal [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of)

    2017-01-15

    To evaluate multi-detector CT (MDCT) coronary angiographic findings of coronary-to-pulmonary artery fistula (CPAF). We retrospectively reviewed images of patients with CPAF from the coronary CT angiography (CCTA) database obtained with a 64-channel MDCT between January 2008 and March 2011. We analyzed the CCTA findings for feeding arteries, fistula, association with peripulmonary arterial aneurysms, and the presence of communication between the CPAF and bronchial arteries. Fifty-five of the 15042 (0.37%) patients were diagnosed with CPAFs. The feeding artery was single (n = 18) or multiple (n = 37). The fistula had a single drainage site (n = 54) or multiple drainage sites (n = 1). The mean diameter of the fistulous opening was 2.7 ± 1.4 mm. A peripulmonary arterial aneurysm was present in 24 (44%) patients. Communication between CPAF and bronchial arteries was present in eight (14.5%) patients. MDCT coronary angiography can provide comprehensive morphologic details on CPAF and may help in presurgical or preinterventional planning.

  13. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  14. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  15. Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Fan, Zhanming; Yu, Wei; Lv, Biao; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China)

    2011-05-15

    To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant ({>=}50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar's test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 {+-} 4.7 mSv. 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF. (orig.)

  16. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  17. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  18. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  19. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  20. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    International Nuclear Information System (INIS)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio; Sanfilippo, Roberto; Montisci, Roberto; Pascalis, Luigi

    2008-01-01

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value ± standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with ≥1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  1. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  2. Multiple detector-row CT angiography of the renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik. E-mail: dominik.fleischmann@univie.ac.at

    2003-03-01

    Computed tomography angiography (CTA) of the abdomen with multiple detector-row computed tomography (MD-CT) is an effective technique for minimally invasive imaging of the renal arteries and the visceral vasculature. This article reviews the clinical and technical aspects of MD-CT angiography in terms of image acquisition and reconstruction parameters, contrast medium application, and three-dimensional visualization with special attention to renal and mesenteric vascular imaging. Because of its high sensitivity to detect renal artery stenosis on the one hand, and because a normal renal CTA virtually excludes the presence of a significant renal artery stenosis on the other hand, renal CTA plays a useful role in the management of patients with suspected renovascular hypertension. Mesenteric CTA is a useful tool for visualizing normal vascular anatomy and its variants--particularly in the setting of organ transplantation. Vascular pathology, e.g. atherosclerotic disease (abdominal angina), or aneurysms of the visceral arteries are reliably assessed with CTA. Mesenteric CTA is an invaluable adjunct to abdominal CT in the setting of abdominal emergencies, because of its ability to detect the causes of acute intestinal ischemia (superior mesenteric artery embolism or thrombosis, superior mesenteric vein thrombosis). Accurate timing of the CTA acquisition and the subsequent parenchymal phase acquisition relative to the contrast medium transit time is critical to obtain excellent image quality in double-pass abdominal CT acquisitions.

  3. The role of multi-detector CT angiography in surgical planning for congenital cervicothoracic kyphoscoliosis: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun; Choi, Won Gyu; Shin, Ho Dong; Hwang, Byeong Wook; Lee, Sang Jin; Lee, Sang Ho [Busan Wooridul Spine Hospital, Busan (Korea, Republic of)

    2008-01-15

    Surgical correction of a cervicothoracic deformity is difficult with a potential risk of vascular injury. Comprehensive preoperative vascular evaluation is important for safe and successful surgery. The use of multi-detector computed tomography angiography (MDCTA) allows a combined display of vascular and osseous structures of the musculoskeletal system. However, no clinical reports have described the use of MDCTA for surgical planning of anterior cervicothoracic surgery in patients with vascular malformation. The case of a 7-year-old girl with congenital cervicothoracic kyphoscoliosis who underwent preoperative MDCTA evaluation and successful correction is presented in this report.

  4. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  5. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  6. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  7. Noninvasive evaluation of cerebral arteriovenous malformations by 4D-CT angiography using 320-detector row CT

    International Nuclear Information System (INIS)

    Tajiri, H.; Jin, L.; Tsukiyama, M.; Suzuki, Y.; Sekine, S.; Shimizu, T.; Ohiwa, T.

    2012-01-01

    Full text: Objective: Four-dimensional computed tomography angiography (4D-CTA) is a new and promising technique in the diagnosis of patients with cerebral arteriovenous malformations (AVMs). The purpose of this retrospective study was to investigate the utility of 4D-CTA using whole-brain 320-detector row CT for assessing cerebral AVMs compared with conventional angiography (CA). Materials and methods: Participants included patients admitted to our institution from November 2010 to March 2012 due to cerebral AVMs who underwent both 4D-CTA and CA within 14 days. The diagnosis of AVM was finally confirmed by CA. Two readers reviewed 4D-CTA and CA under consensus regarding AVM detection rate and each component of the AVM (feeders, nidi, drainers) using a four-point grading scale (excellent=3, good=2, fair=1, poor=0), and the Spetzler-Martin (S-M) grade. Results: During the study period, 11 patients met the inclusion criteria. The average score for feeders, nidi, and drainers was 2.0, 2.3, and 2.5 in 4D-CTA and 2.4, 2.6, and 2.7 in CA, respectively. The average S-M grade score was 2.0 in all patients. There were no statistically significant differences between the two modalities (P<.005). Conclusion: 4D-CTA using 320-detector row CT is a very reliable method and offers diagnostic performance equivalent to CA for detecting and predicting S-M classification of cerebral AVMs.

  8. Multi-detector CT (MDCT in bowel and mesenteric injury

    Directory of Open Access Journals (Sweden)

    Vajjalla Ravikumar

    2013-04-01

    Full Text Available Objectives: To evaluate multi-detector CT (MDCT findings in bowel and mesenteric injury due to blunt abdominal trauma.Method: Retrospective evaluation of MDCT scan reports of patients admitted in Hamad Medical Corporation, Doha, Qatar with bowel and mesenteric injury during the period of January 2005 to April 2008.Results: MDCT, without using oral contrast, clearly demonstrated various specific and less specific findings of bowel and mesenteric injury.Conclusion: Multi-detector CT is an excellent diagnostic modality in bowel and mesenteric injury. Routine administration of oral contrast agent is not mandatory for initial evaluation of these patients.

  9. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  10. Development of a fast multi-line x-ray CT detector for NDT

    International Nuclear Information System (INIS)

    Hofmann, T.; Nachtrab, F.; Schlechter, T.; Mühlbauer, J.; Schröpfer, S.; Firsching, M.; Uhlmann, N.; Neubauer, H.; Ernst, J.; Schweiger, T.; Oberst, M.; Meyer, A.

    2015-01-01

    Typical X-ray detectors for non-destructive testing (NDT) are line detectors or area detectors, like e.g. flat panel detectors. Multi-line detectors are currently only available in medical Computed Tomography (CT) scanners. Compared to flat panel detectors, line and multi-line detectors can achieve much higher frame rates. This allows time-resolved 3D CT scans of an object under investigation. Also, an improved image quality can be achieved due to reduced scattered radiation from object and detector themselves. Another benefit of line and multi-line detectors is that very wide detectors can be assembled easily, while flat panel detectors are usually limited to an imaging field with a size of approx. 40 × 40 cm 2 at maximum. The big disadvantage of line detectors is the limited number of object slices that can be scanned simultaneously. This leads to long scan times for large objects. Volume scans with a multi-line detector are much faster, but with almost similar image quality. Due to the promising properties of multi-line detectors their application outside of medical CT would also be very interesting for NDT. However, medical CT multi-line detectors are optimized for the scanning of human bodies. Many non-medical applications require higher spatial resolutions and/or higher X-ray energies. For those non-medical applications we are developing a fast multi-line X-ray detector.In the scope of this work, we present the current state of the development of the novel detector, which includes several outstanding properties like an adjustable curved design for variable focus-detector-distances, conserving nearly uniform perpendicular irradiation over the entire detector width. Basis of the detector is a specifically designed, radiation hard CMOS imaging sensor with a pixel pitch of 200 μ m. Each pixel has an automatic in-pixel gain adjustment, which allows for both: a very high sensitivity and a wide dynamic range. The final detector is planned to have 256 lines of

  11. Multi-detector CT assessment of traumatic renal lesions

    African Journals Online (AJOL)

    Mohamed Samir Shaaban

    2015-07-10

    Jul 10, 2015 ... Aim of the work: To demonstrate different traumatic lesions of the kidneys using multi-detector. CT, and its use in ... sis and staging of renal trauma and guiding management. © 2015 The ... Emotion 6 (Siemens, Germany), and 16 detectors PHILIPS .... with active bleeding within the hematoma and was man-.

  12. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  13. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  14. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  15. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  16. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    International Nuclear Information System (INIS)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem; Wildi, Stefan; Bauerfeind, Peter

    2007-01-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  17. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  18. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  19. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    International Nuclear Information System (INIS)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip

    2008-01-01

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE

  20. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  1. CT coronary angiography: examination technique, clinical results, and outlook on future developments

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.

    2007-01-01

    Multislice computed tomography (MSCT) after intravenous contrast agent administration enables visualization of the coronary arteries with high spatial resolution (voxel sizes down to 0.5 x 0.35 x 0.35 mm3) and a short scan time. Magnetic resonance imaging (MRI) is also intensively studied with respect to the noninvasive detection of coronary artery stenosis and thus the detection of coronary artery disease (CAD) without radiation exposure but is not equal to MSCT at present. This article provides an overview of the historical development of CT coronary angiography from 4-slice CT to 16-slice CT and 64-slice CT. A crucial aspect of this development is the improvement in image quality resulting from shorter breath-hold periods and the reduced gantry rotation time. Other techniques that appear to considerably improve image quality and accuracy and make CT independent of patient heart rates are multisegment reconstruction and dual-source CT. Sublingual nitroglycerin as well as oral or intravenous betablocker administration should be considered in relation to the diagnostic question to be answered and the patient's heart rate. In the studies available CT coronary angiography with at least 12 simultaneous detector rows has a sensitivity of 96.9 % and a specificity of 75.3 % at the patient level. Especially the negative predictive value of CT (94.6 %) emphasizes the idea that this technique may reliably exclude CAD in patients with intermediate pretest likelihood. In the near future, 256-slice CT will allow examination of the entire heart during one heartbeat or even 4D CT scanning with simultaneous assessment of myocardial perfusion. Automatic or semiautomatic software tools will assume a central place in detecting and quantifying coronary artery stenoses and plaques as well as in the analysis of cardiac function in the clinical setting over the next years. Prior to its routine clinical use, the cost-effectiveness of CT coronary angiography must be determined and the

  2. Low-dose celiac CT angiography with fixed current-time product

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Li Xiaolin; Zhu Shiqiang; Zhang Jiaming; Wang Xiangming; Zou Xiaofeng

    2009-01-01

    Objective: To characterize the feasibility of low-dose CT angiography on 16-slice multi-slice computed tomography (16-MSCT), and its relationship to the noise in the pre-contrast image and enhancement value. Methods: Forty-three consecutive patients (male 21, female 22, mean age 59 years, median age 56 years) underwent abdominal 16-MSCT (Toshiba Aquilion 16) with constant scanning parameters including 120 kVp, a 0.5-second gantry rotation time, a pitch of 0.938: 1, and 16 x 1-mm detector collimation. The mA was set at 200 in the pre-contrast scan and 160 in the contrast-enhanced scan. The arterial phase images were retrospectively reconstructed with 1-mm slice thickness, 0.8 mm interval. The pre-contrast noise was defined as the standard deviation (SD) of the aorta at the level of right posterior crura of diaphragm. The enhancement of aorta was also measured at level of celiac artery. The volume rendering of CT angiography was made and classified into three grades (excellent, good, bad). Receiver operating characteristic curve (ROC) was used to evaluate the relationship between the image quality of CT angiography and noise in the pre-contrast image and enhancement value. Results: Twenty-five cases had the aorta enhancement between 300.0-400.0 HU. The sensitivity and specificity of excellent CTA image was 75% and 62%, respectively when the SD was 12.00. Eighteen cases had the aorta enhancement more than 400.0 HU. The sensitivity and specificity of excellent CTA image was all 100% when the SD was 12.25, and 100% and 75%, respectively when the SD was 13.35. The area under curve of CTA image quality and enhancement in receiver-operated characteristic analysis was 0.907. The enhancement was more than 356.7 HU when the sensitivity and specificity of excellent CTA image was 100% and 60%, respectively, and 389.8 HU when 78% and 80%. When the enhancement was more than 442.4 HU, the specificity of excellent CTA image was 100%. Conclusions: MSCT angiography with low radiation

  3. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    Science.gov (United States)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kaetsu, Yasuhiro; Kitao, Shinichiro; Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro; Ogawa, Toshihide

    2017-07-01

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.

  4. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  5. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  6. Studies on intracranial collateral circulation with multi-slice CT angiography in patients with symptomatic cerebral artery stenosis

    Directory of Open Access Journals (Sweden)

    Shu-qing ZHOU

    2011-06-01

    Full Text Available Objective To explore the features of intracranial collateral circulation in patients with symptomatic cerebral artery stenosis.Method Ninety-four patients with ischemic cerebrovascular disease admitted from Apr.2004 to Jun.2009 were involved in present study.All the patients were examined with cerebral multi-slice CT angiography,and the features of cerebral artery stenosis and intracranial collateral circulation were evaluated using maximum intensity projection(MIP and volume rendering(VR images of CT angiography.Result Of the 94 patients involved,48 were diagnosed as cerebral artery stenosis,including 29 cases of cerebral infarction,18 of transient ischemic attack(TIA and 1 of moyamoya disease(MMD.Among the 14 cases of severe cerebral artery stenosis or occlusion,cerebral infarction was found in 6 cases with lesser intracranial collateral vessels(including massive cerebral infarction in 4 cases and watershed infarction in 2 cases,and focal infarction of central semi-ovale in 1 case and TIA in 7 cases were found with abundant intracranial collateral vessels.Multiple lacunar infarction was found in 22 cases of mild or moderate cerebral artery stenosis,but there was no significant correlation between the stenosed arteries and infarction sites.Abundant intracranial collateral vessels were found in one patient with Moyamoya disease but no infarction was observed.Conclusions Intracranial collateral circulation plays an important role of compensation in patients with severe cerebral artery stenosis or occlusion.Cerebral angiography with multi-slice CT is of great significance in evaluation of cerebral artery stenosis and intracranial collateral circulation.

  7. Multi-Detector CT Findings of Palpable Chest Wall Masses in Children: A Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Ho; Kim, Young Tong [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of); Hong, Hyun Sook [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-03-15

    A wide variety of diseases manifest as palpable chest wall masses in children. These include normal variation, congenital anomalies, trauma, infection, axillary lymphadenopathies, soft tissue tumors and bone tumors. Given that most of these diseases are associated with chest wall deformity, diagnosis is difficult by physical examination or ultrasonography alone. However, multi-detector CT with three dimensional reconstruction is useful in the characterization and differential diagnosis of palpable chest wall lesions. In this article, we review the spectrum of palpable chest wall diseases and illustrate their multi-detector CT presentation.

  8. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  9. Cone-Beam CT with Flat-Panel-Detector Digital Angiography System: Early Experience in Abdominal Interventional Procedures

    International Nuclear Information System (INIS)

    Hirota, Shozo; Nakao, Norio; Yamamoto, Satoshi; Kobayashi, Kaoru; Maeda, Hiroaki; Ishikura, Reiichi; Miura, Koui; Sakamoto, Kiyoshi; Ueda, Ken; Baba, Rika

    2006-01-01

    We developed a cone-beam computed tomography (CBCT) system equipped with a large flat-panel detector. Data obtained by 200 o rotation imaging are reconstructed by means of CBCT to generate three-dimensional images. We report the use of CBCT angiography using CBCT in 10 patients with 8 liver malignancies and 2 hypersplenisms during abdominal interventional procedures. CBCT was very useful for interventional radiologists to confirm a perfusion area of the artery catheter wedged on CT by injection of contrast media through the catheter tip, although the image quality was slightly degraded, scoring as 2.60 on average by streak artifacts. CBCT is space-saving because it does not require a CT system with a gantry, and it is also time-saving because it does not require the transfer of patients

  10. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  11. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  12. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schlattmann, Peter [University Hospital of Friedrich-Schiller University Jena, Department of Medical Statistics, Informatics and Documentation, Jena (Germany); Schuetz, Georg M. [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, Marc [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2011-09-15

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with {<=}16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  13. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    International Nuclear Information System (INIS)

    Schlattmann, Peter; Schuetz, Georg M.; Dewey, Marc

    2011-01-01

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with ≤16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  14. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  15. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  16. A novel APD-based detector module for multi-modality PET/SPECT/CT scanners

    International Nuclear Information System (INIS)

    Saoudi, A.; Lecomte, R.

    1999-01-01

    The lack of anatomical information in SPECT and PET images is one of the major factors limiting the ability to localize and accurately quantify radionuclide uptake in small regions of interest. This problem could be resolved by using multi-modality scanners having the capability to acquire anatomical and functional images simultaneously. The feasibility of a novel detector suitable for measuring high-energy annihilation radiation in PET, medium-energy γ-rays in SPECT and low-energy X-rays in transmission CT is demonstrated and its performance is evaluated for potential use in multi-modality PET/SPECT/CT imaging. The proposed detector consists of a thin CsI(Tl) scintillator sitting on top of a deep GSO/LSO pair read out by an avalanche photodiode. The GSO/LOS pair provides depth-of-interaction information for 511 keV detection in PET, while the thin CsI(Tl) that is essentially transparent to annihilation radiation is used for detecting lower energy X- and γ-rays. The detector performance is compared to that of an LSO/YSO phoswich. Although the implementation of the proposed GSO/LSO/CsI(Tl) detector raises special problems that increase complexity, it generally outperforms the LSO/YSO phoswich for simultaneous PET, SPECT and CT imaging

  17. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  18. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  19. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  20. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  1. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  2. Acute pulmonary embolism in the era of multi-detector CT: a reality in sub-Saharan Africa

    International Nuclear Information System (INIS)

    Tambe, Joshua; Moifo, Boniface; Fongang, Emmanuel; Guegang, Emilienne; Juimo, Alain Georges

    2012-01-01

    The advantages of multi-detector computed tomography (MDCT) have made it the imaging modality of choice for some patients with suspected cardiothoracic disease, of which pulmonary embolism (PE) is an exponent. The aim of this study was to assess the incidence of PE in patients with clinical suspicion of acute PE using MDCT in a sub-Saharan setting, and to describe the demographic characteristics of these patients. Consecutive records of patients who underwent MDCT pulmonary angiography for suspected acute PE over a two-year period at the Radiology Department of a university-affiliated hospital were systematically reviewed. All MDCT pulmonary angiograms were performed with a 16-detector computed tomography (CT) scanner using real-time bolus tracking technique. Authorization for the study was obtained from the institutional authorities. Forty-one MDCT pulmonary angiograms were reviewed of which 37 were retained. Of the 4 excluded studies, 3 were repeat angiograms and 1 study was not technically adequate. Twelve of 37 patients (32.4%) had CT angiograms that were positive for PE, of which 7 were males. The mean age of these patients was 47.6±10.5 years (age range from 33 to 65 years). Twenty five patients out of 37 (67.6%) had CT angiograms that were negative for PE. Eleven PE-positive patients (91.7%) had at least 1 identifiable thromboembolic risk factor whilst 5 PE-negative patients (20%) also had at least a thromboembolic risk factor. The relative risk of the occurrence of PE in patients with at least a thromboembolic risk factor was estimated at 14.4. Acute PE is a reality in sub-Saharan Africa, with an increased likelihood of MDCT evidence in patients with clinical suspicion of PE who have at least a thromboembolic risk factor. The increasing availability of MDCT will help provide more information on the occurrence of PE in these settings

  3. CT Angiography in the Diagnosis of Brain Death

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Bohatyrewicz, Romuald; Walecka, Anna; Sołek-Pastuszka, Joanna; Rowiński, Olgierd; Walecki, Jerzy

    2014-01-01

    Summary Brain death is defined as the irreversible cessation of functioning of the entire brain, including the brainstem. Brain death is principally established using clinical criteria including coma, absence of brainstem reflexes and loss of central drive to breathe assessed with apnea test. In situations in which clinical testing cannot be performed or when uncertainty exists about the reliability of its parts due to confounding conditions ancillary tests (i.a. imaging studies) may be useful. The objective of ancillary tests in the diagnosis of brain death is to demonstrate the absence of cerebral electrical activity (EEG and evoked potentials) or cerebral circulatory arrest. In clinical practice catheter cerebral angiography, perfusion scintigraphy, transcranial Doppler sonography, CT angiography and MR angiography are used. Other methods, like perfusion CT, xenon CT, MR spectroscopy, diffusion weighted MRI and functional MRI are being studied as potentially useful in the diagnosis of brain death. CT angiography has recently attracted attention as a promising alternative to catheter angiography – a reference test in the diagnosis of brain death. Since 1998 several major studies were published and national guidelines were introduced in several countries (e.g. in France, Austria, Switzerland, the Netherlands and Canada). This paper reviews technique, characteristic findings and criteria for the diagnosis of cerebral circulatory arrest in CT angiography

  4. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  5. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  6. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hyeon Hoe [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors.

  7. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    International Nuclear Information System (INIS)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung; Kim, Hyeon Hoe

    2008-01-01

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors

  8. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    Science.gov (United States)

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  10. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

    DEFF Research Database (Denmark)

    Fuchs, Andreas; Kühl, J Tobias; Chen, Marcus Y

    2015-01-01

    BACKGROUND: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis....... We defined target segments on CCTAconv as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTAsub was assessed. No approval from the ethics committee was required according to Danish law. RESULTS: A total of 76 target segments were identified...

  11. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware

    International Nuclear Information System (INIS)

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-01-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration

  12. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  13. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    International Nuclear Information System (INIS)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J.

    2008-01-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  14. Neutron CT with a multi-detector system leading to drastical reduction of the measuring time

    International Nuclear Information System (INIS)

    Hehn, G.; Pfister, G.; Schatz, A.; Goebel, J.; Kofler, R.

    1993-09-01

    By means of numerical simulation methods and their verification with measurements it could be shown that such a detector system can be realized for a line beam and 1-2 detectors per cm. With the maximum available beam width of the fast neutron field at the FRM approximately 20 detectors can be used leading to a reduction of the measuring time to 0,5 - 1 hour. A multi detector system for a line beam of thermal neutrons was constructed, tested and used for CT-measurements. This detector system for the measurement of thinner layers with better spatial resolution could be realized. The electronic discrimination between neutrons and gamma rays has been improved. This discrimination was used in all CT-measurements to get transmission values of both kinds of radiation and to reconstruct to complementary CT-images. The use of a polyenergetic radiation causes spectral shifts in the transmission spectrum leading to artifacts in the reconstructed CT-image. The transmission values must be spectral corrected before image reconstruction, because the image artifacts complicate the image evaluation or make it impossible. A new energy selective procedure for the online spectral correction was developed. This method is based on the concept to measure additionally to the integral transmission value his pulse height spectrum and to do the correction depending on the changes in this pulse height spectrum. (orig./HP) [de

  15. Time-resolved CT angiography in aortic dissection

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Nikolaou, Konstantin; Weidenhagen, Rolf; Hellbach, Katharina; Helck, Andreas; Bamberg, Fabian; Reiser, Maximilian F.; Sommer, Wieland H.

    2012-01-01

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  16. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  17. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  18. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  19. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  20. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  1. Prostatic arterial supply: demonstration by multirow detector Angio CT and Catheter Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Bilhim, Tiago [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Pisco, Joao M. [Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Universidade Nova de Lisboa, Departamento Universitario de Radiologia, Faculdade de Ciencias Medicas, Lisbon (Portugal); Furtado, Andrea; Casal, Diogo; Pais, Diogo; O' Neill, Joao E.G. [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Campos Pinheiro, Luis [Universidade Nova de Lisboa, Departamento Universitario de Urologia, Faculdade de Ciencias Medicas, Lisbon (Portugal)

    2011-05-15

    To evaluate the prostatic arterial supply with multidetector Angio CT and Digital Subtraction Angiography (DSA). DSA was performed in 21 male patients (7 of these also underwent Pelvic Angio CT); a further 4 patients only underwent Angio CT. Prostatic arteries were classified according to their origin, direction, number of pedicles, termination and anastomoses with surrounding arteries in 50 pelvic sides. The most frequent origin was the internal pudendal artery (n = 28; 56%) with the common gluteal-pudendal trunk the next commonest (n = 14; 28%). Less frequent origins were the obturator artery (n = 6; 12%) or the inferior gluteal artery (n = 2; 4%). Two separate vascular pedicles were found in 12 pelvic sides (24%). There were anastomoses with the termination of the internal pudendal artery in 24% of cases (n = 12), with the contra-lateral prostatic arteries in 6 cases (12%), and to the superior vesical artery in 4 cases (8%). Defining prostatic artery origin and direction is paramount to allow selective catheterisation. Angio CT is very useful as a pre-intervention tool. The number of independent vascular pedicles and the presence of anastomoses with surrounding arteries should be taken into account when planning prostatic arterial embolisation. (orig.)

  2. Prostatic arterial supply: demonstration by multirow detector Angio CT and Catheter Angiography

    International Nuclear Information System (INIS)

    Bilhim, Tiago; Pisco, Joao M.; Furtado, Andrea; Casal, Diogo; Pais, Diogo; O'Neill, Joao E.G.; Campos Pinheiro, Luis

    2011-01-01

    To evaluate the prostatic arterial supply with multidetector Angio CT and Digital Subtraction Angiography (DSA). DSA was performed in 21 male patients (7 of these also underwent Pelvic Angio CT); a further 4 patients only underwent Angio CT. Prostatic arteries were classified according to their origin, direction, number of pedicles, termination and anastomoses with surrounding arteries in 50 pelvic sides. The most frequent origin was the internal pudendal artery (n = 28; 56%) with the common gluteal-pudendal trunk the next commonest (n = 14; 28%). Less frequent origins were the obturator artery (n = 6; 12%) or the inferior gluteal artery (n = 2; 4%). Two separate vascular pedicles were found in 12 pelvic sides (24%). There were anastomoses with the termination of the internal pudendal artery in 24% of cases (n = 12), with the contra-lateral prostatic arteries in 6 cases (12%), and to the superior vesical artery in 4 cases (8%). Defining prostatic artery origin and direction is paramount to allow selective catheterisation. Angio CT is very useful as a pre-intervention tool. The number of independent vascular pedicles and the presence of anastomoses with surrounding arteries should be taken into account when planning prostatic arterial embolisation. (orig.)

  3. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  4. Diagnosis of clinical staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Kobayashi, Isao; Igawa, Mikio; Ohnishi, Yoshio; Nakano, Hiroshi; Nihira, Hiromi; Mori, Masaki; Okada, Mitsuo.

    1984-01-01

    The preoperative staging of bladder cancer is of fundamental importance for prognostic evaluation and surgical indication. We studied the accuracy of computed tomography (CT) and angiography in defining the extent of local invasion in 16 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 75 % and 50 % respectively. In low stage, the accuracy was 90 % in CT and 70 % in angiography. In high stage, the accuracy was 50 % in CT and 16.7 % in angiography. Our results seems to indicate lower accuracy in high stage bladder cancer compared with other research. Data from a much larger series are required to ascertain whether the additional information provided by CT and angiography will produce any improvement in patient management. (author)

  5. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  6. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  7. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  8. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  9. Evaluation of patients radiation dose from computed tomography during lower peripheral angiography procedure

    International Nuclear Information System (INIS)

    Khlafallah, Leena Ahmed Ali

    2015-09-01

    The purpose of this study was to evaluate patient radiation doses in lower peripheral angiography CT examinations in Sudan. Survey was conducted in four major hospitals which almost carry out lower peripheral angiography procedures in Sudan at the time of study. All hospitals were equipped with 64 slices multi detectors CT from Toshiba (Japan). The total number of patients was 74. Information on patient's genders and ages, exposure technique factors and radiation dose were collected. The procedures performed in multi phases, up to five phases covering part of the abdomen region, which can make patients exposure reasonably high. CTDI values in the different phases ranged between (13-30) mGy. The total DLP in the four hospitals were 6888.75, 5065.05, 6608.88 and 5754.9 mGy.cm. This study provided first survey for patient dose during lower peripheral angiography procedures in Sudan. Taking into account that the CT machines were similar: the variation between patient's DLP and CTDI values in the different hospitals indicated the need of optimization of radiation protection. Staff training and awareness on factors affecting patient dose are essential.(Author)

  10. Evaluation of aortogenic embolic stroke using multi-detector row CT (MDCT)

    International Nuclear Information System (INIS)

    Mizuno, Masanori; Ooura, Kazumasa; Yamaguchi, Mao; Katsura, Noriyuki; Terayama, Yasuo

    2010-01-01

    Transesophageal cardioechography is one of the useful tools for detecting aortic arteriosclerosis causing aortogenic cerebral embolism. However, it is difficult to perform this method to all of the patients because of the technical difficulties due to patient's condition, especially the severity of atherosclerosis. To avoid the unexpected and adverse events, we are routinely applying multi-detector row CT (MDCT) to those patients. Among 10 cerebral embolic patients with unidentified embolic origin, MDCT revealed arteriosclerotic changes in aorta inducing mobile thrombus in 3 cases. The above data indicates that MDCT is safe and useful tool for diagnosis of aortogenic embolic stroke. (author)

  11. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  12. The usefulness of contrast material injection at the dorsal vein of the hand in 64-detecter row helical CT coronary angiography

    International Nuclear Information System (INIS)

    Kawano, Youji; Yakabe, Kazuaki; Urata, Jungo; Eto, Miyuki; Yamaguchi, Hiroichiro

    2011-01-01

    In 315 cases of multi detector row CT (MDCT) coronary angiography contrast material were injected at the dorsal vein of the hand. Early 168 cases were used 80 ml of 370 mgI/ml contrast material and later 147 cases were used 350-480 mgI/kg contrast material. In all cases contrast material was injected by 4 ml/sec with post injection of 30-40 ml physiologic saline. The attenuation of RCA No.3 and other coronary arteries or coronary artery bypass graft (CABG) graft was measured. In later cases the usefulness of above 300 HU was 95.2%. In all cases the usefulness was 92.6%. (author)

  13. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  14. Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)]. E-mail: rcury@partners.org; Ferencik, Maros [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Achenbach, Stephan [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Department of Internal Medicine II, University of Erlangen (Germany); Pomerantsev, Eugene [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Moselewski, Fabian [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-03-15

    Background: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. Methods: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. Results: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 {+-} 23% versus 64 {+-} 29%; r {sup 2} = 0.83, p < 0.001 and MIP versus QCA: 64 {+-} 22% versus 64 {+-} 29%; r {sup 2} = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 {+-} 12% using CS-MPR and a minimally positive bias of 0.6 {+-} 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, >70%) the agreement between both CS-MPR and MIP was high when compared to QCA ({kappa} = 0.74 and 0.71, respectively). Conclusion: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both

  15. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  16. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  17. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  18. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  19. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  20. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  1. Impaired left ventricular function has a detrimental effect on image quality in multi-detector row CT coronary angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Shaw, S.R.; Marshall, A.J.; Roobottom, C.A.

    2008-01-01

    Aim: To determine whether there is a relationship between left ventricular (LV) haemodynamic parameters, circulation times, and arterial contrast opacification that might affect the image quality of computed tomography (CT) coronary angiography. Methods: Thirty-six patients were included in the study: 18 with cardiomyopathy (CM) and LV dilatation of suspected ischaemic aetiology [age 57.9 ± 13.7 years, range 30-77 years; 14 male, four female; body mass index (BMI) = 27.7 ± 4.5, range 25.5-31.8] and 18 controls (age 62.3 ± 9.4 years, range 47-89 years; 10 male, eight female; BMI 27.8 ± 6.6; range 19.2-33.6). Coronary artery image quality was assessed using a three-point visual scale; contrast medium circulation times, aortic root contrast attenuation, and LV functional parameters were studied. Results: Visually reduced contrast opacification impaired image quality more often in the CM group than the control group (27.4 versus 5.1%). A total of 55.6% CM patients had a contrast transit time ranging from 30-75 s; the number of 'unassessable' segments increased with increasing transit time conforming to a fitted quadratic model (R 2 = 0.74). The relationship between LV ejection fraction and contrast attenuation may also conform to a quadratic model (R 2 = 0.71). Conclusion: LV haemodynamics influence coronary artery opacification using cardiac CT, and users imaging this subgroup must do so with the knowledge of this potential pitfall. The results indicate the need for further studies examining CT protocols in this clinical subgroup

  2. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  3. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  4. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  5. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  6. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  7. Denver screening protocol for blunt cerebrovascular injury reduces the use of multi-detector computed tomography angiography.

    Science.gov (United States)

    Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian

    2014-06-01

    Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.

  8. Radiation Dose and Image Quality from Coronary Angiography in 320-Detecor Row CT

    International Nuclear Information System (INIS)

    Thanomphudsa, J.; Krisanachinda, A.; Tumkosit, M.

    2012-01-01

    Introduction: Coronary Computed Tomography Angiography examinations are increasing rapidly. New Computed Tomography has been developed to improve image quality with the patient dose reduction. The purpose of this study is to evaluate radiation dose and image quality of Coronary Computed Tomography Angiography in patients using 320-detector row CT. Methods: Forty-one patients referred for cardiac CT examinations at King Chulalongkorn Memorial Hospital were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on the 320-detector row CT, Toshiba Aquilion One. Scanning protocol was investigated on dose estimates and image quality. Patients were scanned base on heart rate (HR) by HR 75 bpm use retrospective with dose modulation. Scanning parameters, kVp, mAs, HR, BMI, CTDIvol(mGy) and DLP(mGy.cm), were recorded to study the factors affecting the image quality and patient dose. And mA and kVp setting depend on BMI of the patient. Effective dose is calculated from DLP using specific conversion factor. The image quality was evaluated in 4 vessels by two radiologists. Noise assessment was also studied quantitatively. Results: The patient effective dose in prospective gating 70-80% was 3.6 ± 0.9 mSv, prospective gating 30-80% (1R-R) was 6.3 ± 1.9 mSv, and 30-80% (2R-R) was 10.8 ± 1.8 mSv and in retrospective with tube current modulation was 12.1± 7.7 mSv. Image noise was highest in PGT 70-80% 1R-R and decreased in RGT with tube current modulation, PGT 30-80% 1R-R and lowest in PGT 30-80% 2 R-R. And overall qualitative image quality was mostly good to excellent score. Discussion: The heart rate, heart rate variability and disease of the patient are affecting in the radiation dose and image quality so the suitable acquisition protocol used could be necessary. the effective dose and the image noise for the image quality. (author)

  9. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  10. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  11. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  12. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  13. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  14. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  15. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  16. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  17. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    Science.gov (United States)

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  18. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  19. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Angela [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany)], E-mail: Reichelt.Angela@mh-hannover.de; Hoeper, Marius M. [Department of Respiratory Medicine, Hannover Medical School (Germany); Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany); Keberle, Marc [Department of Diagnostic Radiology and Nuclear Medicine, Bruederkrankenhaus St. Josef Paderborn (Germany)

    2009-07-15

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  20. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    International Nuclear Information System (INIS)

    Reichelt, Angela; Hoeper, Marius M.; Galanski, Michael; Keberle, Marc

    2009-01-01

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  1. Experimental MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for MR animal scanner Bruker 47/20

    Czech Academy of Sciences Publication Activity Database

    Zajíček, J.; Burian, M.; Soukup, P.; Novák, Vladimír; Macko, M.; Jakůbek, J.

    2017-01-01

    Roč. 12, January (2017), č. článku P01015. ISSN 1748-0221 Institutional support: RVO:68378297 Keywords : Gamma camera * SPECT * PET PET /CT * coronary CT angiography (CTA) * Gamma detectors (scintillators, CZT, HPG, HgI etc) * multi-modality systems * pixelated detectors and associated VLSI electronics Subject RIV: JB - Sensors, Measurment, Regulation OBOR OECD: Electrical and electronic engineering Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/01/P01015

  2. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  3. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  4. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  5. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Özgen, Ali, E-mail: draliozgen@hotmail.com [Yeditepe University Hospital, Department of Radiology (Turkey); Sanioğlu, Soner [Yeditepe University Hospital, Department of Cardiovascular Surgery (Turkey); Bingöl, Uğur Anıl [Yeditepe University Hospital, Department of Plastic Surgery (Turkey)

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatinine levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.

  6. Assessment of hepatic arterial variation using multidetector helical CT-angiography

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Lee, Jun Woo; Jun, Woong Bae; Lee, Suk Hong

    2001-01-01

    To evaluate the anatomy of the hepatic artery and normal variants using oblique thick-slab maximal intensity projection (MIP) 3-D CT angiography and multidetector helical CT technology. In 70 patients, axial three-phase CT together with multidetector helical CT and a nonionic contrast agent was used to evaluate liver disease. During the early arterial phase, the parameters were as follow: slice thickness, 2.5 mm; table speed, 15 mm/rotation, pitch, 6; contrast material, 4 ml/sec; total 120 ml. Using the MIP technique and an Advantage window voxtal 3.03 system (GE), the images obtained were reconstructed as 3D angiograms. In each case, the arterial anatomy and its variants were recorded. A typical anatomy was found in 53 cases (75.7%). Common variants were a left hepatic artery arising from the left gastric artery(8 cases, 11.4 %) and a right hepatic artery arising from the superior mesenteric artery(3 cases, 4.3%). Other variant cases were right hepatic artery arising from the gastroduodenal artery(2 cases, 2.9%), a proper hepatic artery arising from the left gastric artery (1 case, 1.4%), a hepatomesenteric trunk (1 case), a hepatogastric/splenomesenteric trunk(1 case), and a celiomesenteric trunk (1 case). 3-D hepatic angiography using multidetector helical CT technology is non-invasive and as accurate as conventional angiography for the evaluation of hepatic arterial anatomy. It is thus considered that 3-D CT angiography is very helpful for the evaluation of hepatic arterial anatomy prior to liver surgery such as transplantation or the treatment of hepatocellular carinoma

  7. 3D-CT angiography with ultrafast CT in the diagnosis of pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Hamada, Seiki; Takamiya, Makoto; Imakita, Satoshi; Yamada, Naoaki; Takase, Kei; Iino, Misako; Nakanishi, Norifumi

    1995-01-01

    The usefulness of 3D-CT angiography (3D-CTA) with ultrafast CT (UFCT) in the diagnosis of pulmonary thromboembolism (PTE) was evaluated. UFCT was carried out in 10 patients with PTE (acute: 5 cases, chronic: 5 cases) and one case with pulmonary artery thrombosis secondary to pulmonary hypertension with atrial septal defect. CT scanning was performed with Imatron C-100XL and C-150L. For the imaging, single-slice step volume scan mode was used with scan time of 100 msec and slice thickness of 6 mm. Contiguous axial images were obtained after contrast enhancement with slice interval of 6 mm. 3D-CTA was reconstructed from 2D-CT images with workstation, and was compared with pulmonary angiograms (PAG) or operative findings. The images of 3D-CTA had good quality and they were more useful than 2D-CT images in better understanding of the configuration and the extent of the thrombi. In comparison with PAG, 3D-CTA gave equivalent information in terms of central pulmonary emboli. Moreover, 3D-CTA had advantages over PAG in demonstrating both the blood lumen and the thrombus on the same image with capability of multi-directional displays. 3D-CTA with UFCT is the useful non-invasive imaging modality in the diagnosis of PTE. (author)

  8. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  9. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    International Nuclear Information System (INIS)

    Efstathopoulos, E P; Kelekis, N L; Pantos, I; Brountzos, E; Argentos, S; Grebac, J; Ziaka, D; Seimenis, I; Katritsis, D G

    2009-01-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  10. The value of unenhanced multi-detector computed tomography ...

    African Journals Online (AJOL)

    Introduction: Unenhanced computed tomography (CT) is used to detect urinary tract calculi with high accuracy. The development of multi-detector CT (MDCT) allows reconstructions in coronal, sagittal and oblique directions. Objective: To compare MDCT with three-dimensional (3D) ultrasound (US) imaging in evaluating ...

  11. The Efficacy of Iopamidol (Pamiray 370) in Aortic and Extremity CT Angiography

    International Nuclear Information System (INIS)

    Lee, Yoo Jin; Lee, Jong Min; Lee, Hui Joong; Park, Ji Won

    2010-01-01

    To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray 370) during an aortic and extremity CT angiography. Between August and December of 2008, 100 patients (M:F=51:49; mean age, 59 years) underwent an aortic and extremity CT angiography using Pamiray 370 based with informed consent. All changes in vital signs, clinical symptoms, and adverse reactions to the contrast media were monitored. Two radiologists assessed the image quality of the CT angiography. A statistical comparison was conducted using an independent t-test and a Mann-Whitney test based on the 100-patient group studied using Optiray 350. The contrast enhancement of the descending aorta in the arterial phase showed a statistically greater efficacy (p<0.001) of Pamiray 370 compared to Optiray 350, which was the routine contrast media for CT angiography for our institute. Adverse reaction signs were evident in 3%(3/100) of the subjects. All of them showed mild and transient reactions such as vomiting (n=2) and coughing (n=1), with no medical treatment required. Contrast media related symptoms including dizziness (n=7), nausea (n=3), headaches (n=2), and injection site pain (n=1), were noted in 12%(12/100). The clinical efficacy of Pamiray 370 was acceptable for the aortic and extremity CT angiography, in terms of clinical safety, tolerance, and image quality

  12. Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

    Directory of Open Access Journals (Sweden)

    Atif N Khan

    2014-01-01

    Full Text Available Objectives: This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA following decennial screening guidelines. Material and Methods: Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from prior published literature for the 64 row CT scanner were compared with data from our study using 320 row detector CT scanner. Data from the 64 row and the 320 row detector CT scanners was used to determine lifetime attributable risks (LAR of cancer based on the biological effects of ionizing radiation (BEIR VII report. Results: The relative reduction of LAR (% for 50-, 60-, and 70-year-old patients undergoing scanning with the 320 row detector CT scanner was 30% lower for lung, and more than 50% lower for female breast when compared with results from 64 row detector CT scanner. The use of 320 row detector CT would result in a combined cumulative cancer incidence of less than 1/500 for breast in women and less than 1/1000 for lung in men; By comparison, this is much lower than other more common risk factors: 16-fold for lung cancer in persistent smokers, 2-fold for breast cancer with a first degree family member history of breast cancer, and 10-fold for thyroid cancer with a family member with thyroid cancer. Decennial screening would benefit at least 355,000 patients from sudden cardiac death each year, 94% of whom have significant coronary artery disease, with at least one stenosis >75%. LAR for thyroid cancer was negligible for both scanners. Conclusion: Lung and female breast LAR reductions with 320 row detector compared with 64 row detector CT are substantial, and the benefits would outweigh increased cancer risks with decennial screening in the age group of 50-70 years.

  13. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  14. Hepatic arterial supply in 1297 CT-angiographies; Die arterielle Leberversorgung in 1297 CT-Angiografien

    Energy Technology Data Exchange (ETDEWEB)

    Loeschner, C.; Kausche, S.; Teichgraeber, U. [Jena University Hospital, Jena (Germany). Dept. of Radiology; Nagel, S.N. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology

    2015-04-15

    Analysis, evaluation and classification of hepatic arterial supply variants and determination of their frequency distribution in CT-angiographies. CT-angiographies of 1,568 patients were evaluated retrospectively for the period between January 1, 2010 and August 30, 2012. The hepatic arterial anatomy was assessed and categorized according to Michels's classification. So far unclassified variants were considered separately. Results: CT-angiographies of 1297 patients were included in the study. Type I according to Michels was seen in 937 cases (72.2%), followed by type V in 114 patients (8.8%) and type III in 83 patients (6.4%). Type X could not be found in any of the patients. Not yet classified variants were discovered in 26 patients. The most frequent variant in this connection was a right hepatic artery originating from the superior mesenteric artery with the left hepatic artery originating from the left gastric artery (n=10). Michels's classification could be largely confirmed on the basis of a radiologically examined patient population. Not yet classified variants were categorized into subgroups of the existing classification.

  15. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  16. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  17. Diagnosis of deep vein thrombosis using multi-detector helical CT

    International Nuclear Information System (INIS)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya

    2002-01-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5±7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  18. Prospective electrocardiogram-gated axial 64-detector computed tomographic angiography vs retrospective gated helical technique to assess coronary artery bypass graft anastomosis. Comparison of image quality and patient radiation dose

    International Nuclear Information System (INIS)

    Machida, Haruhiko; Masukawa, Ai; Tanaka, Isao; Fukui, Rika; Suzuki, Kazufumi; Ueno, Eiko; Kodera, Kojiro; Nakano, Kiyoharu; Shen, Y.

    2010-01-01

    In the present study the effective dose and image quality at distal anastomoses were retrospectively compared between prospective electrocardiogram (ECG)-gated axial and retrospective ECG-gated helical techniques on 64-detector computed tomographic (CT) angiography following coronary artery bypass graft surgery. Following bypass surgery, 52 patients with a heart rate <65 beats/min underwent CT angiography: 26 patients each with prospective and retrospective ECG gating techniques. The effective dose was compared between the 2 groups using a 4-point scale (4, excellent; 1, poor) to grade the quality of curved multiplanar reformation images at distal anastomoses. Patient characteristics of the 2 groups were well matched, and the same CT scan parameters were used for both, except for the interval between surgery and CT examination, tube current, and image noise index. Image quality scores did not differ significantly (3.26±0.95 vs 3.35±0.87; P=0.63), but the effective dose was significantly lower in the prospective (7.3±1.8 mSv) than in the retrospective gating group (23.6±4.5 mSv) (P<0.0001). Following bypass surgery, 64-detector CT angiography using prospective ECG gating is superior to retrospective gating in limiting the radiation dose and maintaining the image quality of distal anastomoses. (author)

  19. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  20. Coronary CT angiography: How should physicians use it wisely and when do physicians request it appropriately?

    International Nuclear Information System (INIS)

    Sun Zhonghua; Aziz, Yang Faridah Abdul; Ng, Kwan-Hoong

    2012-01-01

    Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease due to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with 64- and more slice CT scanners and in selected patients, coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. Although the tremendous contributions of coronary CT angiography to cardiac imaging are acknowledged, appropriate use of cardiac CT as the first line technique by physicians has not been well established. Optimal selection of cardiac CT is essential to ensure acquisition of valuable diagnostic information and avoid unnecessary invasive procedures. This is of paramount importance since cardiac CT not only involves patient risk assessment, prediction of major cardiac events, but also impacts physician decision-making on patient management. Applications of CT in cardiac imaging include coronary artery calcium scoring for predicting the patient risk of developing major cardiac events, followed by coronary CT angiography which is commonly used to determine the diagnostic and prognostic accuracy in the coronary artery disease. This review presents an overview of the applications of CT in cardiac imaging in terms of coronary calcium scoring and coronary CT angiography. Judicious use of both cardiac CT tools will be discussed with regard to their value in different patient risk groups with the aim of identifying the appropriate criteria for choosing a cardiac CT modality. An effective diagnostic pathway is finally recommended to physicians for appropriate selection of cardiac CT in clinical practice.

  1. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  2. Estimation of organ-absorbed radiation doses during 64-detector CT coronary angiography using different acquisition techniques and heart rates: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Kosuke; Koshida, Kichiro; Kawashima, Hiroko (Dept. of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa Univ., Kanazawa (Japan)), email: matsuk@mhs.mp.kanazawa-u.ac.jp; Noto, Kimiya; Takata, Tadanori; Yamamoto, Tomoyuki (Dept. of Radiological Technology, Kanazawa Univ. Hospital, Kanazawa (Japan)); Shimono, Tetsunori (Dept. of Radiology, Hoshigaoka Koseinenkin Hospital, Hirakata (Japan)); Matsui, Osamu (Dept. of Radiology, Faculty of Medicine, Kanazawa Univ., Kanazawa (Japan))

    2011-07-15

    Background: Though appropriate image acquisition parameters allow an effective dose below 1 mSv for CT coronary angiography (CTCA) performed with the latest dual-source CT scanners, a single-source 64-detector CT procedure results in a significant radiation dose due to its technical limitations. Therefore, estimating the radiation doses absorbed by an organ during 64-detector CTCA is important. Purpose: To estimate the radiation doses absorbed by organs located in the chest region during 64-detector CTCA using different acquisition techniques and heart rates. Material and Methods: Absorbed doses for breast, heart, lung, red bone marrow, thymus, and skin were evaluated using an anthropomorphic phantom and radiophotoluminescence glass dosimeters (RPLDs). Electrocardiogram (ECG)-gated helical and ECG-triggered non-helical acquisitions were performed by applying a simulated heart rate of 60 beats per minute (bpm) and ECG-gated helical acquisitions using ECG modulation (ECGM) of the tube current were performed by applying simulated heart rates of 40, 60, and 90 bpm after placing RPLDs on the anatomic location of each organ. The absorbed dose for each organ was calculated by multiplying the calibrated mean dose values of RPLDs with the mass energy coefficient ratio. Results: For all acquisitions, the highest absorbed dose was observed for the heart. When the helical and non-helical acquisitions were performed by applying a simulated heart rate of 60 bpm, the absorbed doses for heart were 215.5, 202.2, and 66.8 mGy for helical, helical with ECGM, and non-helical acquisitions, respectively. When the helical acquisitions using ECGM were performed by applying simulated heart rates of 40, 60, and 90 bpm, the absorbed doses for heart were 178.6, 139.1, and 159.3 mGy, respectively. Conclusion: ECG-triggered non-helical acquisition is recommended to reduce the radiation dose. Also, controlling the patients' heart rate appropriately during ECG-gated helical acquisition with

  3. Assessment of anemia during CT pulmonary angiography

    International Nuclear Information System (INIS)

    Jung, Caroline; Groth, Michael; Bley, Thorsten A.; Henes, Frank O.; Treszl, András; Adam, Gerhard; Bannas, Peter

    2012-01-01

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  4. Assessment of anemia during CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Caroline, E-mail: cjung@uke.de [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Groth, Michael; Bley, Thorsten A.; Henes, Frank O. [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Treszl, András [Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany)

    2012-12-15

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  5. Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Rihyeon; Park, Eun-Ah; Lee, Whal; Chung, Jin Wook [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2016-11-15

    To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation >250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. (orig.)

  6. Radiation dosimetry and its influencing factors for the multi-detector/slice spiral CT

    International Nuclear Information System (INIS)

    Bai Mei; Zheng Junzheng

    2008-01-01

    The Multi-Detector/Slice Spiral Computed Tomography (MDCT/MSCT)reflects the new progress in equipment and technology for radiology. Its popularized application demonstrates its advantages for clinical diagnosis. With the continuous development and growing uses of the MDCT/MSCT, the medical exposure of the patients and public has also been increasing. Therefore, assessment of the radiation dose and radiation risk from X-CT has become an increasingly important concern that should be addressed. Thus, this paper summarizes the main characteristics of the MDCT/MSCT emphasizing particularly on the radiation dosimetry, and reviews the expressions and measures of radiation dose in the MDCT/MSCT. In addition, main factors that influence radiation dose from the MDCT/MSCT are also discussed. A proper grasp of its radiation dosimetry and assessment method can significantly help radiologists, health physicists, medical physicists, X-CT engineers and manufacturers improve the management of radiation dose while optimizing the image quality in the MDCT/MSCT. (authors)

  7. Spiral CT angiography of middle cerebral artery stenoses

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Neff, K.W.; Ries, S.; Sommer, A.; Steinke, W.; Georgi, M.

    1996-01-01

    Transcranial Doppler ultrasonography (TCD) and magnetic resonance angiography (MRA) are well-established techniques for ascertaining intracranial obstructive artery disease. The short examination time required for additional helical CT angiography (CTA) allows quick management of emergency patients already undergoing native CT. However, today the ability of CTA to detect stenoses of the middle cerebral artery (MCA) has not been proven. To analyse the value of CTA in the classification of atherosclerotic disease 23 MCA stenoses confirmed by TCD and MRA were investigated. CTA was performed on a Hispeed advantage scanner (GE) using a bolus injection of 70 ml KM and 40 ml NaCl with a flow rate of 2.5 ml/s, a thickness of 1 mm, a pitch of 1.5 and a 1 mm increment. CTA was presented as maximum intensity projection (MIP) and as multi-projection volume reconstruction (MPVR). A three-step classification of stenosis was compared with the results of TCD and MRA. Good opacification of the MCA was achieved in M1 and M2 segments in all patients. Classification of stenosis by CTA agreed with MRA and TCD in 14 cases; 7 stenoses were assigned to a lower classification by CTA. Two lowgrade stenoses could not be proven by CTA. Although MIP and MPVR yield the same result in stenosis classification MPVR showed a sharper image quality. In contrast to MRA, veins were highly opacified in CTA. Artery and vein were sometimes superimposed, which had to be avoided by changing the projection angle. Medium- and high-grade MCA stenoses can be demonstrated by CTA quickly and reliably. Compared to MRA and TCD, CTA provides lower grading of stenosis. (orig.) [de

  8. Coronary artery anomalies in adults: imaging at dual source CT coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Mourmouris, Christos; Kritikos, Nikolaos; Efthimiadou, Roxani; Andreou, John

    2013-01-01

    Congenital abnormalities of the coronary arteries have an incidence of 1%, and most of these are benign. However, a small number are associated with myocardial ischaemia and sudden death. Various imaging modalities are available for coronary artery assessment. Recently, multi-detector CT has emerged as an accurate diagnostic tool for defining coronary artery anomalies. The purpose of this pictorial essay is to review the dual source CT appearance of congenital anomalies of the coronary arteries in adults.

  9. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  10. Impact of multi-detector row computed tomography on the tactics of cardiovascular surgery. From qualitative evaluation to quantitative assessment

    International Nuclear Information System (INIS)

    Imagawa, Hiroshi; Kawachi, Kanji; Takano, Shinji

    2005-01-01

    We assessed the role of multi-detector row computed tomography in cardiovascular surgery. The efficacy of multi-detector row computed tomography was assessed concerning the graft patency of coronary artery bypass, arterial atheromatous degeneration, small vessel imaging, and left ventricular volume measurement. Images were reconstructed using both the volume-rendering and the maximum-intensity-profile methods. Arterial atherosclerotic degeneration was assessed by aortic wall volume and aortic calcification volume. In the assessment of bypass graft patency, multidetector row computed tomography showed a 98% correct positive ratio with sensitivity and specificity of 98% and 100%, respectively. Atheromatous degeneration showed matching results in more than 70% of cases compared with intraoperative findings. More than 92% of arterial branches with diameters of 3 mm or greater were detected by preoperative multi-detector row computed tomography images, though only 6% of branches with diameters of 2 mm or less could be visualized. There was a positive linear correlation between left ventricular volumes determined by multi-detector row computed tomography and those calculated from cine angiography. Multi-detector row computed tomography clearly visualized coronary bypass grafts and aortic arterial branches, providing detailed vascular images. Atheromatous degeneration assessed by multi-detector row computed tomography was equivalent with intraoperative findings in more than 70% of cases. Left ventricular volumes measured by multi-detector row computed tomography correlated closely with those determined by cine-angiography. Multidetector row computed tomography is an efficient and promising modality in cardiovascular surgery. (author)

  11. Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences

    International Nuclear Information System (INIS)

    Garcarek, Jerzy; Kurcz, Jacek; Guziński, Maciej; Banasik, Mirosław; Miś, Marcin; Gołębiowski, Tomasz

    2015-01-01

    High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1–2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6–8 mL of Iodixanol (320 mg/mL) diluted with saline to 18–24 mL was administered at a speed of 4–5 mL/s. Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of

  12. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  13. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J.; Xu, J.

    2010-01-01

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 ± 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  14. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  15. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  16. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  17. Diagnosis of arterial sequestration using multidetector CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Li Huimin, E-mail: lihuiminphd@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China)

    2010-11-15

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  18. Diagnosis of arterial sequestration using multidetector CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  19. Dose reduction strategies for cardiac CT

    International Nuclear Information System (INIS)

    Midgley, S.M.; Einsiedel, P.; Langenberg, F.; Lui, E.

    2010-01-01

    Full text: Recent advances in CT technology have produced brighter X-ray sources. gantries capable of increased rotation speeds, faster scintil lation materials arranged into multiple rows of detectors, and associated advances in 3D reconstruction methods. These innovations have allowed multi-detector CT to be turned to the diagnosis of cardiac abnormalities and compliment traditional imaging techniques such as coronary angiography. This study examines the cardiac imaging solution offered by the Siemens Somatom Definition Dual Source 64 slice CT scanner. Our dose reduction strategies involve optimising the data acquisition protocols according to diagnostic task, patient size and heart rate. The relationship between scan parameters, image quality and patient dose is examined and verified against measurements with phantoms representing the standard size patient. The dose reduction strategies are reviewed with reference to survey results of patient dose. Some cases allow the insertion of shielding to protect radiosensitive organs, and results are presented to quantify the dose saving.

  20. Venous variants and anomalies on routine abdominal multi-detector row CT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent; Tokmak, Naime

    2007-01-01

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation

  1. Venous variants and anomalies on routine abdominal multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Oguzkurt, Levent [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Tokmak, Naime [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)

    2007-02-15

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation.

  2. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the

  3. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    International Nuclear Information System (INIS)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker; Floegel, Thomas; Kitzler, Hagen H.; Alexandrov, Andrei V.

    2016-01-01

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r s = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  4. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Floegel, Thomas [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Kitzler, Hagen H. [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Alexandrov, Andrei V. [The University of Tennessee Health Science Center, Department of Neurology, Memphis, TN (United States)

    2016-09-15

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r{sub s} = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  5. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  6. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    Science.gov (United States)

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  8. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  9. Perfusion CT in childhood stroke—Initial observations and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Zebedin, D., E-mail: doris.zebedin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria); Sorantin, E.; Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria)

    2013-07-15

    Introduction: To report the preliminary results of contrast-enhanced perfusion multi-detector CT for diagnoses of perfusion disturbances in children with clinical suspicion of stroke. Patients and methods: Within the last two years emergency perfusion CT was performed in ten children (age: 8–17 years, male:female = 3:7) for assessment of suspected childhood stroke. These intracranial perfusion CT, intracranial CT-digital subtraction angiography (CT-DSA) and extracranial CT-angiography (CTA) studies were retrospectively reviewed and compared with MRI, follow-up CT, catheter angiography and final clinical diagnosis. The total dose length product (DLP) for the entire examination was recorded. The image quality of perfusion CT-maps, CT-DSA and CTA were evaluated with a subjective three-point scale ranging from very good to non-diagnostic image quality rating perfusion disturbance, intracranial peripheral vessel depiction, and motion- or streak artifacts. Results: In nine of ten children perfusion CT showed no false positive or false negative results. In one of ten children suffering from migraine focal hypo-perfusion was read as perfusion impairment potentially indicating early stroke, but MRI and MRA follow-up were negative. Overall, perfusion-CT with CT-DSA was rated very good in 80% of cases for the detection of perfusion disturbances and vessel anatomy. Conclusions: In comparison to standard CT, contrast-enhanced perfusion CT improves CTs’ diagnostic capability in the emergency examination of children with a strong suspicion of ischemic cerebral infarction.

  10. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  11. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    International Nuclear Information System (INIS)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo

    2013-01-01

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  12. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo [Children' s Hospital, Fudan University, Department of Radiology, Shanghai (China)

    2013-07-15

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  13. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  14. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao; Failla, Bruna Bonaventura

    2013-01-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  15. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  16. Liver hydatid cyst ruptured into the thorax: CT angiography findings of a case

    International Nuclear Information System (INIS)

    Kara, K.; Ors, F.; Bozlar, U.; Tasar, M.

    2012-01-01

    Full text: Introduction: Intrathoracic rupture of hepatic hydatid cyst is a rare but severe condition causing a spectrum of lesions to the pleura, lung parenchyma, and bronchi. Pulmonary complications result from the proximity of hydatid cysts in the liver and the diaphragm. Objectives and tasks: In this report we aimed to present computed tomography (CT) angiography findings of a case with liver hydatid cyst ruptured into the thorax. The patient underwent CT angiography examination with suspicion of pulmonary embolism. Materials and methods: A 71-year-old female patient admitted to our emergency department with complaints of severe and persistent cough. Basal region of the right hemithorax could not get breath sounds on physical examination. Chest radiography revealed the presence of consolidation-effusion. The patient was treated with antibiotherapy for pneumonia and parapneumonic effusion. Because of the clinical symptoms and chest radiograph findings persisted the patient underwent CT angiography examination with suspicion of pulmonary embolism. Results: On CT angiography images pulmonary artery and its branches were normal. There were subtotal collapse in the right middle and lower lung lobes and complicated cystic lesion that has air densities in the basal interlobar space. Another thick walled complicated cystic lesion with multiple septations and air densities was detected in the right posterior liver lobe. The right hemidiaphragm was interrupted and the right liver lobe partially herniated into the thorax cavity. Serologic tests were positive for Echinococcus granulosus and there were prior therapy history for liver cyst hydatid. The diagnostic aspiration findings were consistent with hydatid cyst lesion. Conclusion: In patients with hepatic hydatid cyst associated with persistent and severe cough, thoracic rupture of the cyst should be considered in differential diagnosis. CT angiography is fast, non-invasive and effective method in the detection of

  17. Renal computed angiography. Part I: Renal CT arteriography in hypertension

    International Nuclear Information System (INIS)

    Al-Amin, M.; Hadjidekov, V.

    2012-01-01

    Visualization of renal vasculature is needed in several clinical condition among which hypertension is dominant. CT angiography now day replaces catheter angiography as non-invasive method. The goal of this study is to present initial authors experience in visualization of renal arteries using 64 MDCT and to evaluated the utility in hypertensive patients. MDCT assures excellent assessment of renal arteries conditions. Multiplanar reconstruction and allow better delineation in tortuous vessels course and anatomic variants. (authors)

  18. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT.

    Science.gov (United States)

    Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko

    2012-06-01

    Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Left ventricular functional parameters and geometric patterns in Korean adults on coronary CT angiography with a 320-detector-row CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Cho, Won Jin; Kim, Young Dae [College of Medicine, Dong-A University, Busan (Korea, Republic of); Shin, Kyung Min; Lim, Jae Kwang; Lee, Jong Min [Dept. of Radiology, Kyungpook National University, Daegu (Korea, Republic of)

    2017-08-01

    To assess the normal reference values of left ventricle (LV) functional parameters in Korean adults on coronary CT angiography (CCTA) with a 320-detector-row CT scanner, and to analyze sex-related differences and correlations with various clinical characteristics. This study retrospectively enrolled 172 subjects (107 men and 65 women; age, 58 ± 10.9 years; body surface area [BSA], 1.75 ± 0.2 m{sup 2}) who underwent CCTA without any prior history of cardiac disease. The following parameters were measured by post-processing the CT data: LV volume, LV functional parameters (ejection fraction, stroke volume, cardiac output, etc.), LV myocardial mass, LV inner diameter, and LV myocardial thickness (including septal wall thickness [SWT], posterior wall thickness [PWT], and relative wall thickness [RWT = 2 × PWT / LV inner diameter]). All of the functional or volumetric parameters were normalized using the BSA. The general characteristics and co-morbidities for the enrolled subjects were recorded, and the correlations between these factors and the LV parameters were then evaluated. The LV myocardial thickness (SWT, 1.08 ± 0.18 cm vs. 0.90 ± 0.17 cm, p < 0.001; PWT, 0.91 ± 0.15 cm vs. 0.78 ± 0.10 cm, p < 0.001; RWT, 0.38 ± 0.08 cm vs. 0.33 ± 0.05 cm, p < 0.001), LV volume (LV end-diastolic volume, 112.9 ± 26.1 mL vs. 98.2 ± 21.0 mL, p < 0.001; LV end-systolic volume, 41.7 ± 14.7 mL vs. 33.7 ± 12.2 mL, p = 0.001) and mass (145.0 ± 29.1 g vs. 107.9 ± 20.0 g, p < 0.001) were significantly greater in men than in women. However, these differences were not significant after normalization using BSA, except for the LV mass (LV mass index, 79.6 ± 14.0 g/m{sup 2} vs. 66.2 ± 11.0 g/m{sup 2},p < 0.001). The cardiac output and ejection fraction were not significantly different between the men and women (cardiac output, 4.3 ± 1.0 L/min vs. 4.2 ± 0.9 L/min, p = 0.452; ejection fraction, 63.4 ± 7.7% vs. 66.4 ± 7.6%, p = 0.079). Most of the LV parameters were

  20. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  1. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  2. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  3. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  4. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  5. Research of z-axis geometric dose efficiency in multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Moon Chan

    2006-01-01

    With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  9. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  10. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  11. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiromichi [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Matsushita, Shonosuke, E-mail: shomatsu@md.tsukuba.ac.jp [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Tsukuba University of Technology, Tsukuba, Ibaraki 305-8521 (Japan); Hyodo, Kazuyuki [High Energy Accelerator Research Organization, KEK, Tsukuba, Ibaraki 305-0801 (Japan); Sato, Yukio; Sakakibara, Yuzuru [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan)

    2013-03-01

    Synchrotron radiation angiography with a HARP detector made it possible to evaluate impaired pulmonary microcirculation in pulmonary emphysema by means of high sensitivity. Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity.

  12. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    International Nuclear Information System (INIS)

    Ito, Hiromichi; Matsushita, Shonosuke; Hyodo, Kazuyuki; Sato, Yukio; Sakakibara, Yuzuru

    2013-01-01

    Synchrotron radiation angiography with a HARP detector made it possible to evaluate impaired pulmonary microcirculation in pulmonary emphysema by means of high sensitivity. Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity

  13. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  14. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility

    International Nuclear Information System (INIS)

    Wormanns, Dag; Marheine, Anke; Beyer, Florian; Heindel, Walter; Diederich, Stefan; Kohl, Gerhard; Klotz, Ernst

    2004-01-01

    The aim of this study was to assess the in vivo measurement precision of a software tool for volumetric analysis of pulmonary nodules from two consecutive low-dose multi-row detector CT scans. A total of 151 pulmonary nodules (diameter 2.2-20.5 mm, mean diameter 7.4±4.5 mm) in ten subjects with pulmonary metastases were examined with low-dose four-detector-row CT (120 kVp, 20 mAs (effective), collimation 4 x 1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm; Somatom VolumeZoom, Siemens). Two consecutive low-dose scans covering the whole lung were performed within 10 min. Nodule volume was determined for all pulmonary nodules visually detected in both scans using the volumetry tool included in the Siemens LungCare software. The 95% limits of agreement between nodule volume measurements on different scans were calculated using the Bland and Altman method for assessing measurement agreement. Intra- and interobserver agreement of volume measurement were determined using repetitive measurements of 50 randomly selected nodules at the same scan by the same and different observers. Taking into account all 151 nodules, 95% limits of agreement were -20.4 to 21.9% (standard error 1.5%); they were -19.3 to 20.4% (standard error 1.7%) for 105 nodules <10 mm. Limits of agreement were -3.9 to 5.7% for intraobserver and -5.5 to 6.6% for interobserver agreement. Precision of in vivo volumetric analysis of nodules with an automatic volumetry software tool was sufficiently high to allow for detection of clinically relevant growth in small pulmonary nodules. (orig.)

  15. CT angiography using electron-beam computed tomography (EBCT). A phantom study

    International Nuclear Information System (INIS)

    Uchino, Akira; Kato, Akira; Kudo, Sho

    1997-01-01

    The purpose of this study was to evaluate the accuracy of CT angiography in small vessels using electron-beam computed tomography (EBCT). Vessel phantoms with inner diameters of 8 mm, 6 mm, and 4 mm were prepared with segments of 75%, 50%, and 25% stenosis in each vessel. The vessels were filled with contrast medium (Iopamidol 300 at 1/24 dilution, approximately 380 HU). The EBCT apparatus used was an Imatron C-150. The step volume scan mode was used with slice thicknesses of 1.5 mm and 3.0 mm, scan time of 0.3 sec, and 210 mm field of view. Images with a slice thickness of 1.5 mm were definitely better than those with a slice thickness of 3.0 mm. The quality of maximum intensity projection (MIP) images was quite similar to that of three-dimensional (3D) images. Using the 8 mm vessel phantom, all stenotic segments were accurately visualized on CT angiography. The 50% stenotic segments were accurately estimated in all vessels. However, the 75% stenotic segments were slightly overestimated in smaller vessels, and the 25% stenotic segments were slightly underestimated in smaller vessels. We consider CT angiography using EBCT to be a useful, less invasive diagnostic modality for stenoocclusive lesions. (author)

  16. Usefulness of the Negative Multidetector CT Angiography in Patients with Suspected Pulmonary Embolism

    International Nuclear Information System (INIS)

    Holguin Holguin, Alfonso Jose; Lombana, Milton; Collazos, Giovanny; Bravo, Hector; Abella Calle, Jose

    2012-01-01

    Objective: The aim of the study is to evaluate alternative findings in pulmonary CT angiography using MDCT reported as negative in patients with suspected pulmonary embolism. Material and method: Cross sectional study with 178 patients. We recognized other findings reported in pulmonary CT angiography using MDCT whose result was negative. Subsequently these findings were classified into six different categories of clinical relevance and their association with clinical scenario was analyzed. Results: from November 2004 to June 2007 we requested 231 pulmonary CT angiography using MDCT in patients with suspected pulmonary embolism. 217 patients were included in the final analysis. Of these, 39 (185) were positive for pulmonary embolism. The 178 remaining negative studies, 8.43% were normal, 53.37% were classified as category A, 20.79% category B, 14.04% category C; category D 1.12% and 2.25% were not interpretable. The most frequent diagnoses were pneumonia, interstitial lung disease and cardiogenic pulmonary edema. It was less likely to find a normal report whether the study was requested in the hospital department in emergency patients (OR = 0.38 95% 0.16 to 0.88, p = 0.0007). No differences were found in other categories or between patients younger or older than 65 years (p = 0.436). Conclusion: Pulmonary CT angiography as first line imaging tool in patients with suspected pulmonary embolism is useful, offering alternative diagnoses in hospitalized and emergency room patients, regardless of their age and clinical findings.

  17. Cone-beam CT angiography of the thorax. An experimental study

    International Nuclear Information System (INIS)

    Yoshida, Katsuya; Shimada, Kazuhiro; Tadokoro, Hiroyuki

    1999-01-01

    The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256 x 256 x 256 voxel volume with a voxel dimension of 0.9 x 0.9 x 0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging. (author)

  18. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  19. Multidetector CT: a new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Piva, Tommaso; Lovato, Luigi; Fattori, Rossella; Gavelli, Giampaolo

    2005-01-01

    Purpose: From the early 90s, spiral CT technology has considerably changed the diagnostic capability of Pulmonary Embolism (PE), giving a direct vision of intravascular thrombi. Further technological progress has straightened its diagnostic impact leading to an essential role in clinical practice. The advent of Multi-Detector CT (MDCT) has subsequently increased the reliability of this technique to the point of undermining the role of pulmonary angiography as the gold standard and occupying a central position in diagnostic algorithms. The aim of this paper is to appraise this evolution by means of a meta-analysis of the relevant literature from 1995 to 2004. Results: The review of the literature showed the sensitivity and specificity of CT to have increased from 37-94% and 91-100% (single detector CT) to 87-94% and 94-100% (4-channel multidetector CT), especially thanks to the possibility of depicting subsegmental clots, with an interobserver agreement of 0.63-0.94 (k). Conclusions: CT is one of the most reliable and effective methods in the diagnosis is PE, with the advantage of being extremely fast and providing alternative diagnoses. Recent improvements in MDCT technology confers the highest value of diagnostic accuracy with respect to other imaging modalities such as scintigraphy, angiography, MRI, D-dimer essay and Doppler US [it

  20. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    Science.gov (United States)

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  1. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  2. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  3. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  4. Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen.

    Science.gov (United States)

    Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy

    2003-10-01

    To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003

  5. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Sakamoto, Ichiro [Kyushu University, Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Fukuoka (Japan); Yamamura, Kenichiro [Kyushu University, Department of Pediatrics, Graduate School of Medical Sciences, Fukuoka (Japan); Yabuuchi, Hidetake [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-02-15

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. (orig.)

  6. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography

    International Nuclear Information System (INIS)

    Yamasaki, Yuzo; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Honda, Hiroshi; Nagao, Michinobu; Kawanami, Satoshi; Sakamoto, Ichiro; Yamamura, Kenichiro; Yabuuchi, Hidetake

    2017-01-01

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. (orig.)

  7. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  8. Use of multi-detector CT angiography in identification and classification of aorto-iliac diseases; clinical and surgical application

    Directory of Open Access Journals (Sweden)

    Reda Abdelsamie Alarabawy

    2016-03-01

    Conclusions: MDCT angiography is excellent noninvasive scanning technique for patients suspected of having aorto-iliac occlusive disease, with higher spatial resolution and faster acquisition times, allowing assessment of the aorta and its branches with greater accuracy than other modalities.

  9. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  10. Variations in the origins of the thyroid arteries on CT angiography.

    Science.gov (United States)

    Esen, Kaan; Ozgur, Anil; Balci, Yuksel; Tok, Sermin; Kara, Engin

    2018-02-01

    To investigate the anatomical variations in the origins of the thyroid arteries on CT angiography images. The presence and the origins of the superior thyroid artery, the inferior thyroid artery, and the thyroidea ima artery were retrospectively evaluated based on carotid CT angiography examinations. The bifurcation level of the common carotid artery with respect to the cervical vertebrae and disc spaces was also determined. A total of 640 patients were included in the study. The right and left superior thyroid arteries arose from the external carotid artery in 413 (64.5%) and 254 (39.7%) patients, from the bifurcation of the common carotid artery in 131 (20.5%) and 148 (23.1%) patients, and from the common carotid artery in 90 (14.1%) and 226 (35.3%) patients, respectively. We could not observe the right and the left superior thyroid arteries in 6 (0.9%) and 12 (1.9%) of the patients, respectively. However, the right and left inferior thyroid arteries were not identified in 14 (2.2%) and 45 (7%) of the patients, respectively. The thyroidea ima artery was detected in 2.3% of the patients. The visualization of thyroid arteries on CT angiography images enables the anatomy of the arterial supply system of the thyroid gland to be explored in a noninvasive manner prior to surgery.

  11. Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT

    International Nuclear Information System (INIS)

    Xue Yuejun; Qian Nong; Shao Yanhui; Pan Changjie; Rong Weiliang; Xu Yiqun

    2012-01-01

    Objective: To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS). Methods: A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot, SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated. Results: The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22 ± 0.01)mSv, which was lower by 76.31% than that of DE-CTA. Conclusions: Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality. (authors)

  12. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Archana [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); St. Christopher' s Hospital for Children, Department of Radiology, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); New York Cardiovascular Institute at Lenox Hill Radiology, New York, NY (United States); Servaes, Sabah; Keller, Marc S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Schwartz, Mathew C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Levine Children' s Hospital, Sanger Heart and Vascular Institute, Charlotte, NC (United States); Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging/Radiology, Orlando, FL (United States)

    2017-03-15

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  13. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Malik, Archana; Hellinger, Jeffrey C.; Servaes, Sabah; Keller, Marc S.; Schwartz, Mathew C.; Epelman, Monica

    2017-01-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  14. Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaus, Victor; Grosse Hokamp, Nils; Abdullayev, Nuran; Maus, Volker; Kabbasch, Christoph; Mpotsaris, Anastasios; Maintz, David; Borggrefe, Jan [University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne (Germany)

    2018-03-15

    To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA). Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance. Compared to polyenergetic images, although noise increased with lower keV, CNR (p < 0.02) and SNR (p > 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p < 0.0001 each). Compared to polyenergetic images, virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches. (orig.)

  15. Development of a rapid multi-line detector for industrial computed tomography

    International Nuclear Information System (INIS)

    Nachtrab, Frank; Firsching, Markus; Hofmann, Thomas; Uhlmann, Norman; Neubauer, Harald; Nowak, Arne

    2015-01-01

    In this paper we present the development of a rapid multi-row detector is optimized for industrial computed tomography. With a high frame rate, high spatial resolution and the ability to use up to 450 kVp it is particularly suitable for applications such as fast acquisition of large objects, inline CT or time-resolved 4D CT. (Contains PowerPoint slides). [de

  16. Improved Imaging in Cardiac Patients: echocardiography and CT-coronary angiography

    NARCIS (Netherlands)

    T.W. Galema (Tjebbe)

    2010-01-01

    textabstractDiff erent non-invasive imaging modalities are used for to assess cardiac anatomy and function. Echocardiography and MRI allow assessment of cardiac structures and function of the cardiac chambers and valves as well as perfusion of the left ventricular wall while CT-angiography in

  17. Diagnosis of preoperative staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Munechika, Hirotsugu; Saito, Kazuhiko; Tanaka, Osamu; Tomiie, Fumitaka; Aihara, Toshinori

    1982-01-01

    The accuracy of computed tomography (CT) and angiography in defining the extent of local invasion was studied retrospectively in 19 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 54 percent and 47 percent respectively. The diagnosis of carcinoma of the bladder by CT tended to do overstaging rather than understaging. A tangential view of the tumor-bearing area by the selective internal iliac arteriography allows an accurate estimation of the perivesical tumor extension. The topographic diagnosis should be made by CT prior to the angiographic study. (author)

  18. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  19. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT.

    Science.gov (United States)

    Ananthakrishnan, Lakshmi; Rajiah, Prabhakar; Ahn, Richard; Rassouli, Negin; Xi, Yin; Soesbe, Todd C; Lewis, Matthew A; Lenkinski, Robert E; Leyendecker, John R; Abbara, Suhny

    2017-03-01

    To assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images. In this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale. Mean difference between unenhanced and VNC attenuation was VNC attenuation were equivalent in all tissues except fat using a threshold of VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase. VNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.

  20. Multi-detector computed tomography of acute abdomen

    International Nuclear Information System (INIS)

    Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Marincek, Borut; University Hospital of Zurich

    2005-01-01

    Acute abdominal pain is one of the most common causes for referrals to the emergency department. The sudden onset of severe abdominal pain characterising the ''acute abdomen'' requires rapid and accurate identification of a potentially life-threatening abdominal pathology to provide a timely referral to the appropriate physician. While the physical examination and laboratory investigations are often non-specific, computed tomography (CT) has evolved as the first-line imaging modality in patients with an acute abdomen. Because the new multi-detector CT (MDCT) scanner generations provide increased speed, greater volume coverage and thinner slices, the acceptance of CT for abdominal imaging has increased rapidly. The goal of this article is to discuss the role of MDCT in the diagnostic work-up of acute abdominal pain. (orig.)

  1. Diagnostic Accuracy of the Volume Rendering Images of Multi-Detector CT for the Detection of Lumbar Transverse Process Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Hak; Chun, Tong Jin [Dept. of Radiology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2012-01-15

    To compare the accuracy of three-dimensional computed tomographic (3D CT) volume rendering techniques with axial images of multi-detector row computed tomography to identify lumbar transverse process (LTP) fractures in trauma patients. We retrospectively evaluated 42 patients with back pain as a result of blunt trauma between January and June of 2010. Two radiologists examined the 3D CT volume rendering images independently. The confirmation of a LTP fracture was based on the consensus of the axial images by the two radiologists. The results of 3D CT volume rendering images were compared with the axial images and the diagnostic powers (sensitivity, specificity, and accuracy) were calculated. Seven of the 42 patients had twenty five lumbar transverse process fractures. The diagnostic power of the 3D CT volume rendering technique is as accurate as axial images. Reader 1, sensitivity 96%, specificity 100%, accuracy 99.9%; and Reader 2 sensitivity 100%, specificity 99.8%, accuracy 99.8%. The accordance of the two radiologists was 99.8%. 3D CT volume rendering images can alternate axial images to detect lumbar transverse process fractures with good image quality.

  2. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  3. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  4. Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    NARCIS (Netherlands)

    Smit, Jeroen M.; Dimopoulou, Angeliki; Liss, Anders G.; Zeebregts, Clark J.; Kildal, Morten; Whitaker, Iain S.; Magnusson, Anders; Acosta, Rafael

    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in

  5. Minimally invasive autopsy employing post-mortem CT and targeted coronary angiography: evaluation of its application to a routine Coronial service.

    Science.gov (United States)

    Roberts, Ian S D; Traill, Zoe C

    2014-01-01

    Post-mortem imaging is a potential alternative to traditional medicolegal autopsy. We investigate the reduction in number of invasive autopsies required by use of post-mortem CT ± coronary angiography. A total of 120 adult deaths referred to the Coroner were investigated by CT, with coronary angiography employed only for the second series of 60 cases, in order to determine the added value of angiography. The confidence of imaging cause of death was classified as definite (no autopsy), probable, possible or unascertained. Invasive autopsy was not required in 38% of cases without coronary angiography and 70% of cases with angiography. Full autopsy, including brain dissection, was required in only 9% of cases. There was complete agreement between autopsy and radiological causes of death in the cases with a 'probable' imaging cause of death, indicating that cases for which imaging provides an accurate cause of death without autopsy were identified correctly. In two patients, CT demonstrated unsuspected fractures, not detected at subsequent autopsy. A two-thirds reduction in the number of invasive coronial autopsies can be achieved by use of post-mortem CT plus coronary angiography. At the same time, use of post-mortem CT may improve accuracy of diagnosis, particularly for traumatic deaths. © 2013 John Wiley & Sons Ltd.

  6. Scimitar syndrome: multi detector computed tomography angiography findings of a case

    International Nuclear Information System (INIS)

    Aslan, A.; Bozlar, U.; Ors, F.; Tasar, M.

    2012-01-01

    Full text: Introduction: Scimitar syndrome also known as pulmonary venolobar syndrome is a rare congenital abnormality. This abnormality consists of ipsilateral anomalous pulmonary venous drainage of right lung into the inferior vena cava (IVC), with hypoplasia of the right lung, an anomalous systemic arterial supply from supradiaphragmatic aorta to the right lower lobe and dextrocardia. Objectives and tasks: In this article, we aimed to present multidetector computed tomography (MDCT) angiography findings of a case with scimitar syndrome. Material and methods: 21 year old male with dextrocardia and anomalous curvilinear density in the right lower lobe directed toward the right hemidiaphragm on chest radiography was evaluated with MDCT angiography examination. Results: Dextrocardia and interruption of IVC with azygous continuation was detected in MDCT angiography examination. Vertically directing right superior pulmonary vein was draining to the suprahepatic segment of IVC. Pulmonary sequestration in the right lower lobe taking feeder from celiac trunk was detected. Right pulmonary artery was hypoplastic and bronchial tree was abnormal, manifesting as a mirror image in both lung lobes. Conclusion: MDCT angiography is very successful imaging method in demonstrating the anomalous pulmonary vein and assessing pulmonary arterial and bronchial anomalies

  7. Improved dynamic CT angiography visualization by flow territory masking

    Directory of Open Access Journals (Sweden)

    Søren Christensen

    2015-01-01

    Full Text Available Backgound and Purpose: Computerized tomography (CT perfusion (or CTP source images from CT scanners with small detector widths can be used to create a dynamic CT angiogram (CTA similar to digital subtraction angiography (DSA. Because CTP studies use a single intravenous injection, all arterial territories enhance simultaneously, and individual arterial territories [i.e., anterior cerebral artery (ACA, middle cerebral artery (MCA, and posterior cerebral artery (PCA] cannot be delineated. This limits the ability to assess collateral flow patterns on dynamic CTAs. The aim of this study was to devise and test a postprocessing method to selectively color-label the major arterial territories on dynamic CTA. Materials and Methods: We identified 22 acute-stroke patients who underwent CTP on a 320-slice CT scanner within 6 h from symptom onset. For each case, two investigators independently generated an arterial territory map from CTP bolus arrival maps using a semiautomated method. The volumes of the arterial territories were calculated for each map and the average relative difference between these volumes was calculated for each case as a measure of interrater agreement. Arterial territory maps were superimposed on the dynamic CTA to create a vessel-selective dynamic CTA with color-coding of the main arterial territories. Two experts rated the arterial territory maps and the color-coded CTAs for consistency with expected arterial territories on a 3-point scale (excellent, moderate, poor. Results: Arterial territory maps were generated for all 22 patients. The median difference in arterial territory volumes between investigators was 2.2% [interquartile range (IQR 0.6-8.5%]. Based on expert review, the arterial territory maps and the vessel-selective dynamic CTAs showed excellent consistency with the expected arterial territories in 18 of 22 patients, moderate consistency in 2 patients, and poor consistency in another 2 patients. Conclusion: Using a

  8. WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

    International Nuclear Information System (INIS)

    Pelc, N; McCollough, C; Yu, L; Schmidt, T

    2014-01-01

    Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical

  9. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    Science.gov (United States)

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  10. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  11. The role of CT and cerebral angiography in the neurosurgical treatment of cerebrovascular diseases and their sequels

    International Nuclear Information System (INIS)

    Bock, W.J.

    1979-01-01

    It is found that for cerebro-vascular diseases which can be surgically treated, neither angiography nor CT alone yields sufficient information. Only a combination of the two methods can help to reach a clear decision; CT is better suited for course control while angiography helps to make a diagnosis and to decide upon the best surgical treatment. (orig./AJ) [de

  12. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  13. Using multi-detector-row CT to diagnose ampullary adenoma or adenocarcinoma in situ

    International Nuclear Information System (INIS)

    Lee, Myungsu; Kim, Myeong-Jin; Park, Mi-Suk; Choi, Jin-Young; Chung, Yong Eun

    2011-01-01

    Objective: To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. Materials and methods: We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients without periampullary tumor. Three radiologists blindly and independently reviewed CT images. The sensitivities and specificities for identification of ampullary masses were calculated in all cases and in cases with adequate duodenal distension. The sensitivities and specificities for the diagnosis of ampullary tumors were calculated using the following criteria: identification of mass alone; presence of extrahepatic bile duct (EBD) dilation or identification of mass; presence of pancreatic duct (PD) dilation or identification of mass. Paired t-tests were performed to assess differences in mean values. Results: The mean sensitivity and specificity of MDCT for the detection of an ampullary mass in all cases were 47.6% and 86.4%, and in cases with adequate duodenal distension, 66.7% (p = 0.07) and 80.5% (p = 0.32), respectively. When the presence of EBD dilation or identification of mass were used as criteria, the mean sensitivity and specificity were 73.0% (p = 0.03) and 60.6% (p = 0.03), respectively. When presence of PD dilation or identification of mass were used as criteria, the mean sensitivity and specificity were 47.6% and 81.8% (p = 0.23). Conclusions: MDCT is moderately accurate for the diagnosis of ampullary adenoma or adenocarcinoma in situ. When EBD dilation or identification of mass were used as criteria, the sensitivity can be improved.

  14. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  15. Basic and clinical studies of visualizing right inferior phrenic artery by multi detector row-CT

    International Nuclear Information System (INIS)

    Okumura, Yusuke; Takahashi, Shiro; Suzuki, Masayuki; Takemura, Akihiro; Matsui, Osamu; Takada, Tadanori; Kawahara, Kazuhiro; Matsuura, Yukihiro

    2007-01-01

    To perform transcatheter arterial embolization (TAE) successfully, it is important to obtain information about parasitic arterial supply to the hepatocellular carcinoma (HCC). Among these extrahepatic collateral vessels, the right inferior phrenic artery (RIPA) is the most frequent and important extrahepatic collateral artery supplying the HCC. In the present study, we obtained multi-planar reformation (MPR) images of RIPA using multi detector row computed tomography (MDCT), assessed the ability of MDCT to demonstrate the origin of RIPA, and then analyzed the morphology of the origin. In a basic study using an original phantom simulating vessel origin, the origin was poorly visualized depending on the phantom diameter and angle of the origin to the scanned section. A clinical study was performed in 28 patients with HCC who underwent both MDCT and angiography within a short period. In 19 of 28 patients, RIPA originated at the celiac artery. In 3 patients, RIPA originated at the right renal artery, and in 6, directly at the abdominal aorta. The origin of RIPA was categorized into four patterns according to the inclination of the origin on transverse sections of MDCT. RIPA that originated at the right renal artery and showed an upward course perpendicular to the scan section of MDCT were most clearly visualized at the origin. In addition, RIPA could be observed in an optional direction on the workstation. Pre-angiographic visualization of the origin of RIPA may save angiographic time, curtail contrast medium, and reduce radiation exposure. (author)

  16. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients

    International Nuclear Information System (INIS)

    Iyengar, S.S.; Morgan-Hughes, G.; Ukoumunne, O.; Clayton, B.; Davies, E.J.; Nikolaou, V.; Hyde, C.J.; Shore, A.C.; Roobottom, C.A.

    2016-01-01

    Aim: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Materials and methods: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥50%) stenosis and secondarily as the presence of severe (≥70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. Results: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. Conclusion: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. - Highlights: • Diagnostic accuracy of High-Definition CT Angiography (HD-CTCA) has been assessed. • Invasive Coronary angiography (ICA) is the reference standard. • Diagnostic accuracy of HD-CTCA is comparable to ICA. • Diagnostic accuracy is not affected by coronary calcium or stents. • HD-CTCA provides a non-invasive alternative in high-risk patients.

  17. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  18. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  19. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  20. The psychological impact of test results following diagnostic coronary CT angiography.

    Science.gov (United States)

    Devcich, Daniel A; Ellis, Christopher J; Broadbent, Elizabeth; Gamble, Greg; Petrie, Keith J

    2012-11-01

    Coronary computed tomography (CT) angiography is an advanced cardiac imaging test commonly used for diagnosing early signs of ischemic heart disease. Despite its importance in cardiology, little is known about its psychological effect on patients. The present study sought to examine these effects in relation to illness perceptions, cardiac health behavior intentions, and subsequent health behaviors. Forty-five nonacute cardiac patients who were referred for diagnostic coronary CT angiography completed questionnaires prior to testing and following the receipt of test results, at which point illness perceptions and intentions to take cardiac medication, as well as diet and exercise intentions were measured. Exercise and dietary behaviors were measured at follow-up 6 weeks later. Changes on these variables were then compared between patients diagnosed with normal arteries and patients diagnosed with diseased arteries. Compared to positive-testing patients, patients with normal test results reported significant changes toward more positive illness perceptions following testing, with improvements in emotional effect of illness, illness concern, consequences, and personal control of illness. The illness perception of treatment control was seen as more important among positive-testing patients, whereas both groups reported increases in illness coherence. Health behavior intentions (cardiac medication intentions and exercise intentions) increased for positive-testing patients only, as did physical activity at follow-up. Diagnosis-dependent psychological effects can be detected following coronary CT angiography. These effects have important implications for patient health and health care in diagnostic contexts, and the results from this study can be used to guide further research in this area.

  1. Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck.

    Science.gov (United States)

    Neuhaus, Victor; Große Hokamp, Nils; Abdullayev, Nuran; Maus, Volker; Kabbasch, Christoph; Mpotsaris, Anastasios; Maintz, David; Borggrefe, Jan

    2018-03-01

    To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA). Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance. Compared to polyenergetic images, although noise increased with lower keV, CNR (p 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches. • Virtual monoenergetic images greatly improve attenuation, while noise only slightly increases. • Virtual monoenergetic images show superior contrast-to-noise ratios compared to polyenergetic images. • Virtual monoenergetic images significantly improve image quality at low keV.

  2. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  3. Intravenous flat-detector CT angiography in acute ischemic stroke management

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands); Obadia, Michael [Fondation Rothschild Hospital, Department of Neurology, Paris (France); Alamowitch, Sonia [APHP Hopital Tenon, Universite Paris VI, Department of Neurology, Paris (France)

    2012-04-15

    In the settings of stroke, a non-invasive high-resolution imaging modality to visualize the arterial intracranial circulation in the interventional lab is a helpful mean to plan the endovascular recanalization procedure. We report our initial experience with intravenously enhanced flat-detector CT (IV FDCT) technology in the detection of obstructed intracranial arteries. Fourteen consecutive patients elected for endovascular stroke therapy underwent IV FDCT. The scans were intravenously enhanced and acquired in accordance with the previously calculated bolus arrival time. Images were processed on a commercially available workstation for reconstructions and 3D manipulation. Occlusion level and clot length, the quality of collateral vessels, and the patency of anterior and posterior communicating arteries were assessed. IV FDCT was performed successfully in all the cases and allowed for clot location and length visualization, assessment of communicating arteries patency, and evaluation of vessel collateral grade. Information obtained from this technique was considered useful for patients treated by endovascular approach. Retrospective review of the images by two independent readers was considered accurate and reproducible. IV FDCT technology provided accurate delineation of obstructed vessel segments in acute ischemic stroke disease. It gave a significant help in the interventional strategy. This new technology available in the operating room might provide a valuable tool in emerging endovascular stroke therapy. (orig.)

  4. Intravenous flat-detector CT angiography in acute ischemic stroke management

    International Nuclear Information System (INIS)

    Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel; Babic, Drazenko; Obadia, Michael; Alamowitch, Sonia

    2012-01-01

    In the settings of stroke, a non-invasive high-resolution imaging modality to visualize the arterial intracranial circulation in the interventional lab is a helpful mean to plan the endovascular recanalization procedure. We report our initial experience with intravenously enhanced flat-detector CT (IV FDCT) technology in the detection of obstructed intracranial arteries. Fourteen consecutive patients elected for endovascular stroke therapy underwent IV FDCT. The scans were intravenously enhanced and acquired in accordance with the previously calculated bolus arrival time. Images were processed on a commercially available workstation for reconstructions and 3D manipulation. Occlusion level and clot length, the quality of collateral vessels, and the patency of anterior and posterior communicating arteries were assessed. IV FDCT was performed successfully in all the cases and allowed for clot location and length visualization, assessment of communicating arteries patency, and evaluation of vessel collateral grade. Information obtained from this technique was considered useful for patients treated by endovascular approach. Retrospective review of the images by two independent readers was considered accurate and reproducible. IV FDCT technology provided accurate delineation of obstructed vessel segments in acute ischemic stroke disease. It gave a significant help in the interventional strategy. This new technology available in the operating room might provide a valuable tool in emerging endovascular stroke therapy. (orig.)

  5. CT findings of intraductal papillary neoplasm of the bile duct: Assessment with multiphase contrast-enhanced examination using multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H., E-mail: ogawa.hiroshi@h.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Japanese Red Cross Nagoya Daiichi Hospital, Nagoya (Japan); Nagasaka, T. [Department of Medical Technology, Nagoya University School of Health Sciences, Nagoya (Japan); Suzuki, K. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Ota, T. [Department of Radiology, Aichi Medical University Hospital, Nagakute Aichi (Japan); Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2012-03-15

    Aim: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. Materials and methods: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1 mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. Results: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20 mm (n = 32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n = 31), not hyperdense during the portal-venous and delayed phases (n = 36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n = 27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. Conclusions: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.

  6. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  7. Contribution of multi-detector row CT (MDCT) to decision making in the management of patients with small bowel obstruction or ileus

    International Nuclear Information System (INIS)

    Osada, Hisato; Watanabe, Wataru; Okada, Taketomo

    2007-01-01

    We retrospectively evaluated the contribution of multi-detector row CT (MDCT) to patient management decisions in 62 patients with small bowel obstruction or ileus. The sensitivity and specificity of MDCT diagnosis of small bowel obstruction with strangulation or closed loop were 78.9% (15/19) and 93.0% (40/43), respectively. In 19 patients with small bowel obstruction with strangulation or closed loop, the median interval between CT examination and the commencement of surgery was significantly longer in misdiagnosed patients than in those correctly diagnosed (43.3 vs. 4.5 hours, p<0.05). Only two patients displayed severe physical signs that required urgent surgical treatment. Our results suggest that MDCT plays a key role in the management of patients with small bowel obstruction. (author)

  8. Anomalous origin of coronary artery: the role of multislice CT Angiography: a case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Daniel Rocha; Barros, Marcio Vinicius Lins; Nunes, Maria do Carmo Pereira; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil)

    2012-07-15

    Anomalous origin of coronary arteries is a relatively rare entity and can present different clinical forms. Recently, CT angiography of the coronary arteries have demonstrated an important role in the diagnosis and management of these anomalies. We present the case of a young female without significant comorbidities who presented with cardiopulmonary arrest, being revived by a team of customer service mobile emergency. After completion of multislice CT angiography of the coronary arteries was observed anomalous origin of left main coronary artery in the right coronary artery, no signs of extrinsic compression. Patient received a defibrillator and had an uneventful follow-up performed. Multislice CT angiography is minimally invasive diagnostic methods to detect the origin and trajectory of the coronary arteries, allowing an alternative to cardiac catheterization for evaluation of patients with anomalous origin of coronary arteries. (author)

  9. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  10. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  11. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  12. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  13. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  14. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  15. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  17. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  18. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography.

    Science.gov (United States)

    Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E

    2016-09-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.

  19. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  20. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  1. Impact of imaging quality of change pitch on coronary CTA with 64-detector row CT

    International Nuclear Information System (INIS)

    Li Xiang; Jin Chaolin; Zhang Shutong

    2009-01-01

    Objective: To investigate the impact of imaging quality of pitch on coronary CT angiography (CTA) with 64-detector row CT. Methods: 566 patients were divided into four groups according to heart rate (≤ 50, 51 ∼ 70, 71 ∼ 80 and ≥ 80 bpm). Three dimensional reconstructions were used such as volume rendering (VR), maximum intensity projection(MIP) and curved planar reformation (CPR). Each group was divided into control group and experimential group randomly, using normal pitch and revised pitch respectively, and the imaging quality and influencing factors were analyzed among the four groups. Results: There was significant difference in imaging quality among the four groups (P < 0.05). Each group had difference in imaging quality with normal pitch and revised pitch. Conclusions: The revised pitch helps to improve the imaging quality and meet the demand of diagnosis. (authors)

  2. The evaluation of the radiation dose and image quality through the change of the tube voltage in cerebral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Won; Jung, Kang Kyo; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography (MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography (BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation 128 x 0.6 mm, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0 mm, Increment 5.0 mm, Delay Time 3.0 sec, Care Dose 4D (Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120 kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18 % higher in Signal to Noise Ratio and 19 % in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50 % with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80 kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

  3. Extent of hypoattenuation on CT angiography source images in basilar artery occlusion: prognostic value in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Puetz, Volker; Khomenko, Andrei; Hill, Michael D; Dzialowski, Imanuel; Michel, Patrik; Weimar, Christian; Wijman, Christine A C; Mattle, Heinrich P; Engelter, Stefan T; Muir, Keith W; Pfefferkorn, Thomas; Tanne, David; Szabo, Kristina; Kappelle, L Jaap; Algra, Ale; von Kummer, Ruediger; Demchuk, Andrew M; Schonewille, Wouter J

    2011-12-01

    The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.

  4. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    Science.gov (United States)

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  5. Determining the proportion of coronary segments assessable on 16-slice CT coronary angiography: a brief report

    International Nuclear Information System (INIS)

    Soon, K. H.; Cox, N.; Eccleston, D.; Lim, Y.; Chaitowitz, I.; Bell, K. W.; Kelly, A-M.

    2007-01-01

    Computed tomography coronary angiography (CT-CA) is becoming a popular non-invasive coronary imaging method. We aimed to determine the proportion of coronary segments assessable on a 16-slice CT in comparison with conventional selective coronary angiography (SCA). We identified all patients who had both 16-slice CT-CA and recent SCA (less than 12 months) from March 2004 to July 2005. Two CT reporters blinded to SCA independently classified coronary segment assessability on CT-CA. A cardiologist blinded to CT findings classified assess-ability of coronary segments on SCA. Data were analysed using descriptive statistics and proportion of agreement. Ninety-five study pairs were included in the analysis. Of those, 1161 coronary segments were deemed assessable on SCA and 1103 segments (95%) were also assessable on CT-CA. Nonassessable segments on CT-CA were predominantly in the distal segments and branches of coronary arteries. Reasons for nonassessability were small calibre (48.3%), motion artefacts (20.7%) and poorly reconstructed segments (22.4%). The 16-slice CT was able to assess a high proportion of but not all coronary segments. Nonassessable segments were predominantly distal segments or branches of coronary arteries. Motion artefacts due to heart-rate changes, small calibre and poorly reconstructed images were main causes of nonassessability on 16-slice CT-CA

  6. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  7. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  8. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  9. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    International Nuclear Information System (INIS)

    Caro-Dominguez, Pablo; Manson, David E.; Compton, Gregory; Humpl, Tilman

    2016-01-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  10. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Manson, David E. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Compton, Gregory [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Epworth Hospital, Epworth Medical Imaging, Richmond, VIC (Australia); Humpl, Tilman [University of Toronto, Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON (Canada)

    2016-09-15

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  11. Multicenter Comparison of Contrast-Enhanced FDG PET/CT and 64-Slice Multi-Detector-Row CT for Initial Staging and Response Evaluation at the End of Treatment in Patients With Lymphoma.

    Science.gov (United States)

    Gómez León, Nieves; Delgado-Bolton, Roberto C; Del Campo Del Val, Lourdes; Cabezas, Beatriz; Arranz, Reyes; García, Marta; Cannata, Jimena; González Ortega, Saturnino; Pérez Sáez, Mª Ángeles; López-Botet, Begoña; Rodríguez-Vigil, Beatriz; Mateo, Marta; Colletti, Patrick M; Rubello, Domenico; Carreras, José L

    2017-08-01

    To compare staging correctness between contrast-enhanced FDG PET/ceCT and 64-slice multi-detector-row CT (ceCT64) for initial staging and response evaluation at the end of treatment (EOT) in patients with Hodgkin lymphoma, diffuse large B cell lymphoma (DLBCL), and follicular lymphoma. This prospective study compared initial staging and response evaluation at EOT. One hundred eighty-one patients were randomly assigned to either ceCT64 or FDG PET/ceCT. A nuclear medicine physician and a radiologist read FDG PET/ceCT scans independently and achieved post hoc consensus, whereas another independent radiologist interpreted ceCT64 separately. The reference standard included all clinical information, all tests, and follow-up. Ethics committees of the participating centers approved the study, and all participants provided written consent. Ninety-one patients were randomized to ceCT64 and 90 to FDG PET/ceCT; 72 had Hodgkin lymphoma, 72 had DLBCL, and 37 had follicular lymphoma. There was excellent correlation between the reference standard and initial staging for both FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84), although evaluation of the response at EOT was excellent only for FDG PET/ceCT (κ = 0.91). Our study demonstrated satisfactory agreement between FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84) in initial staging compared with the reference standard (P = 0.16). Response evaluation at EOT with FDG PET/ceCT (κ = 0.91) was superior compared with ceCT64 (κ = 0.307) (P < 0.001).

  12. Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters

    International Nuclear Information System (INIS)

    Honda, Osamu; Sumikawa, Hiromitsu; Johkoh, Takeshi; Tomiyama, Noriyuki; Mihara, Naoki; Inoue, Atsuo; Tsubamoto, Mitsuko; Natsag, Javzandulam; Hamada, Seiki; Nakamura, Hironobu

    2007-01-01

    Purpose: To investigate differences in volumetric measurement of pulmonary nodules caused by changing the reconstruction parameters for multi-detector row CT. Materials and methods: Thirty-nine pulmonary nodules less than 2 cm in diameter were examined by multi-slice CT. All nodules were solid, and located in the peripheral part of the lungs. The resultant 48 parameters images were reconstructed by changing slice thickness (1.25, 2.5, 3.75, or 5 mm), field of view (FOV: 10, 20, or 30 cm), algorithm (high-spatial frequency algorithm or low-spatial frequency algorithm) and reconstruction interval (reconstruction with 50% overlapping of the reconstructed slices or non-overlapping reconstruction). Volumetric measurements were calculated using commercially available software. The differences between nodule volumes were analyzed by the Kruskal-Wallis test and the Wilcoxon Signed-Ranks test. Results: The diameter of the nodules was 8.7 ± 2.7 mm on average, ranging from 4.3 to 16.4 mm. Pulmonary nodule volume did not change significantly with changes in slice thickness or FOV (p > 0.05), but was significantly larger with the high-spatial frequency algorithm than the low-spatial frequency algorithm (p < 0.05), except for one reconstruction parameter. The volumes determined by non-overlapping reconstruction were significantly larger than those of overlapping reconstruction (p < 0.05), except for a 1.25 mm thickness with 10 cm FOV with the high-spatial frequency algorithm, and 5 mm thickness. The maximum difference in measured volume was 16% on average between the 1.25 mm slice thickness/10 cm FOV/high-spatial frequency algorithm parameters and overlapping reconstruction. Conclusion: Volumetric measurements of pulmonary nodules differ with changes in the reconstruction parameters, with a tendency toward larger volumes in high-spatial frequency algorithm and non-overlapping reconstruction compared to the low-spatial frequency algorithm and overlapping reconstruction

  13. Cardiac CT for the assessment of chest pain: Imaging techniques and clinical results

    International Nuclear Information System (INIS)

    Becker, Hans-Christoph; Johnson, Thorsten

    2012-01-01

    Immediate and efficient risk stratification and management of patients with acute chest pain in the emergency department is challenging. Traditional management of these patients includes serial ECG, laboratory tests and further on radionuclide perfusion imaging or ECG treadmill testing. Due to the advances of multi-detector CT technology, dedicated coronary CT angiography provides the potential to rapidly and reliably diagnose or exclude acute coronary artery disease. Life-threatening causes of chest pain, such as aortic dissection and pulmonary embolism can simultaneously be assessed with a single scan, sometimes referred to as “triple rule out” scan. With appropriate patient selection, cardiac CT can accurately diagnose heart disease or other sources of chest pain, markedly decrease health care costs, and reliably predict clinical outcomes. This article reviews imaging techniques and clinical results for CT been used to evaluate patients with chest pain entering the emergency department.

  14. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  15. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  16. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  17. Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT

    International Nuclear Information System (INIS)

    Johnston, Jennifer H.; Podberesky, Daniel J.; Larson, David B.; Alsip, Christopher; Yoshizumi, Terry T.; Angel, Erin; Barelli, Alessandra; Toncheva, Greta; Egelhoff, John C.; Anderson-Evans, Colin; Nguyen, Giao B.; Frush, Donald P.; Salisbury, Shelia R.

    2013-01-01

    Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting. (orig.)

  18. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  19. Spatial relationship between intrahepatic artery and portal vein based on the fusion image of CT-arterial portography (CTAP) and CT-angiography (CTA): New classification for hepatic artery at hepatic hilum and the segmentation of right anterior section of the liver

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Takeguchi, Takaya; Fukuda, Hozumi; Abe, Shoko; Tobe, Kimiko; Tanaka, Rei; Tagawa, Kazumi

    2012-01-01

    Purpose: To clarify the variations of the intrahepatic artery and portal vein and to verify the proper segmentation for the right anterior section of the liver. Materials and methods: CT during arterial portography and CT angiography were performed on 64-slice multi detector row CT in 147 patients. All images were transferred to a workstation for analysis using multi-image-fusion mode. We investigated the spatial relationship between hepatic artery and portal vein in the right hemiliver and the segmentation of the right anterior hepatic artery and portal vein. Results: The spatial anatomy of right hepatic arteries and portal vein was (1) anterior and posterior hepatic artery run superior and inferior to anterior portal vein, respectively (47.6%), (2) one anterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (15%), (3) anterior and posterior hepatic arteries run superior to anterior portal vein (11.6%), (4) anterior and posterior hepatic arteries run inferior to anterior portal vein (7.5%), and (5) one posterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (6.8%). The combined anatomy of right anterior artery and portal vein with regard to segmentation was classified as (1) dorso-ventral (26.5%), (2) dorso-ventral and inferior (10.9%), (3) multiple (18.4%), and (4) superior and inferior segments (1.4%). Conclusion: There are various types of spatial anatomy of intrahepatic artery and portal vein. The hepatic arteries as well as portal veins of right anterior section of the liver could be divided into dorsal and ventral, not superior and inferior.

  20. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  1. Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality

    International Nuclear Information System (INIS)

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes. (author)

  2. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  3. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume......Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...

  4. Usefulness of computed tomography angiography for the detection of high-risk aortas for carotid artery stenting

    International Nuclear Information System (INIS)

    Yamamoto, Hiromichi; Kuwayama, Naoya; Hayashi, Nakamasa; Kubo, Michiya; Endo, Shunro

    2011-01-01

    This study evaluated the usefulness of computed tomography (CT) angiography for the detection of high-risk aortas for carotid artery stenting (CAS). We investigated changes in the treatment method and modifications of endovascular techniques according to the information from CT angiography. CT angiography using three-dimensional and multi-planar reconstruction was performed in 43 consecutive patients with carotid artery stenoses intended to undergo CAS. Two neurosurgeons evaluated the images and estimated the risk and difficulties of CAS. CT angiography clearly depicted the entire aorta, the supra-aortic vessels, and the ilio-femoral arteries in all patients. Abnormal vascular findings were found in 17 patients. High-risk aortic lesions for CAS were detected in 5 patients, including thick aortic plaques with thrombi in 2. We changed the treatment strategy from CAS to carotid endarterectomy (CEA) in these 2 patients. CT angiograms proved very useful in evaluating the approach routes of CAS in 12 patients. One patient had dissecting aneurysm of the thoracic aorta and another had aberrant right vertebral artery. In these two, the treatment strategy was changed from CAS to CEA. The treatment method was changed in 4 patients in total. CT angiography is useful for the detection of high-risk aortas for CAS and for the evaluation of safe approaches to the carotid artery. (author)

  5. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience; Angiotomografia computadorizada de coronarias com tomografo com 320 fileiras de detectores e utilizando o AIDR-3D: experiencia inicial

    Energy Technology Data Exchange (ETDEWEB)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao, E-mail: roberto.neto@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Failla, Bruna Bonaventura [Universidade Metodista de Sao Paulo, Sao Bernardo do Campo, SP (Brazil)

    2013-07-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  6. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  7. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  8. Interesting detector shapes for 3rd generation CT

    Energy Technology Data Exchange (ETDEWEB)

    Kachelriess, Marc [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. of Medical Physics (IMP)

    2011-07-01

    Third generation CT scanners typically comprise detectors which are flat or whose shape is the segment of a cylinder or a sphere that is focussed onto the focal spot of the X-ray source. There appear to be two design criteria that favor this choice of detector shape. One is the possibility of performing fan-beam and cone-beam filtered backprojection in the native geometry (without rebinning) and the other criterium is to enable the use of focussed anti scatter grids. It is less known, however, that other detector shapes may also have these properties. While these designs have been evaluated for 2D CT from a rather theoretical standpoint more than one decade ago we revisit and generalize these considerations, extend them to 3D circular, sequential and spiral cone-beam CT and propose an optimal design in terms of detector costs. (orig.)

  9. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  10. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  11. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    Science.gov (United States)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  12. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  13. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  14. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna [Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow (India)

    2010-06-15

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  15. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    Science.gov (United States)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  16. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    International Nuclear Information System (INIS)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  17. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

    International Nuclear Information System (INIS)

    Beeres, Martin; Schell, Boris; Mastragelopoulos, Aristidis; Kerl, Josef Matthias; Gruber-Rouh, Tatjana; Lee, Clara; Siebenhandl, Petra; Bodelle, Boris; Zangos, Stephan; Vogl, Thomas J.; Jacobi, Volkmar; Bauer, Ralf W.; Herrmann, Eva

    2012-01-01

    To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). (orig.)

  18. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  19. Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm.

    Science.gov (United States)

    Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo

    2018-02-01

    Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

  20. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A. [University Medical Center Utrecht and Wilhelmina Children' s Hospital, Department of Radiology, Utrecht (Netherlands)

    2012-02-15

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  1. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A.

    2012-01-01

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  2. Generalised brain edema and brain infarct in ergotamine abuse: Visualization by CT, MR and angiography

    International Nuclear Information System (INIS)

    Toedt, C.; Hoetzinger, H.; Salbeck, R.; Beyer, H.K.

    1989-01-01

    Abuse of ergotamine can release a generalised brain edema and brain infarctions. This can be visualized by CT, MR and angiography. The reason, however, can only be found in the patients history. (orig.) [de

  3. Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

    International Nuclear Information System (INIS)

    Mo, Yuan Heng; Jaw, Fu Shan; Wang, Yung Cheng; Jeng, Chin Ming; Peng, Shinn Forng

    2011-01-01

    The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 ± 17 and 80 ± 10 mmHg; 120 ± 14 and 80 ± 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 ± 9.3 and 70.6 ± 8.9 mL/m2; 23.5 ± 5.7 and 25.6 ± 3.7 mL/m2, 66.5 ± 5.1% and 63.5 ± 4.6%, respectively). The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

  4. Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, Tobias; Hauer, Michael; Doerfler, Arnd [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Banckwitz, Rosemarie; Koehler, Christoph [Siemens AG, Healthcare Sector, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc, Hoffman Estates, IL (United States); University of Wisconsin, Department of Biomedical Engineering and School of Medicine and Public Health, Madison, WI (United States)

    2014-06-15

    Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols. Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer. (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv. The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. (orig.)

  5. Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology

    International Nuclear Information System (INIS)

    Struffert, Tobias; Hauer, Michael; Doerfler, Arnd; Banckwitz, Rosemarie; Koehler, Christoph; Royalty, Kevin

    2014-01-01

    Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols. Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer. (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv. The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. (orig.)

  6. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  7. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  8. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  9. A new technique for noise reduction at coronary CT angiography with multi-phase data-averaging and non-rigid image registration

    Energy Technology Data Exchange (ETDEWEB)

    Tatsugami, Fuminari; Higaki, Toru; Nakamura, Yuko; Yamagami, Takuji; Date, Shuji; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Minami-ku, Hiroshima (Japan); Fujioka, Chikako; Kiguchi, Masao [Hiroshima University, Department of Radiology, Minami-ku, Hiroshima (Japan); Kihara, Yasuki [Hiroshima University, Department of Cardiovascular Medicine, Minami-ku, Hiroshima (Japan)

    2015-01-15

    To investigate the feasibility of a newly developed noise reduction technique at coronary CT angiography (CTA) that uses multi-phase data-averaging and non-rigid image registration. Sixty-five patients underwent coronary CTA with prospective ECG-triggering. The range of the phase window was set at 70-80 % of the R-R interval. First, three sets of consecutive volume data at 70 %, 75 % and 80 % of the R-R interval were prepared. Second, we applied non-rigid registration to align the 70 % and 80 % images to the 75 % image. Finally, we performed weighted averaging of the three images and generated a de-noised image. The image noise and contrast-to-noise ratio (CNR) in the proximal coronary arteries between the conventional 75 % and the de-noised images were compared. Two radiologists evaluated the image quality using a 5-point scale (1, poor; 5, excellent). On de-noised images, mean image noise was significantly lower than on conventional 75 % images (18.3 HU ± 2.6 vs. 23.0 HU ± 3.3, P < 0.01) and the CNR was significantly higher (P < 0.01). The mean image quality score for conventional 75 % and de-noised images was 3.9 and 4.4, respectively (P < 0.01). Our method reduces image noise and improves image quality at coronary CTA. (orig.)

  10. Closing in on the K Edge : Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System

    NARCIS (Netherlands)

    Meyer, Mathias; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, Thomas

    2014-01-01

    Purpose: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. Materials and Methods: All

  11. A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images.

    Science.gov (United States)

    Mendonca, Paulo R S; Lamb, Peter; Sahani, Dushyant V

    2014-01-01

    The ability of dual-energy computed-tomographic (CT) systems to determine the concentration of constituent materials in a mixture, known as material decomposition, is the basis for many of dual-energy CT's clinical applications. However, the complex composition of tissues and organs in the human body poses a challenge for many material decomposition methods, which assume the presence of only two, or at most three, materials in the mixture. We developed a flexible, model-based method that extends dual-energy CT's core material decomposition capability to handle more complex situations, in which it is necessary to disambiguate among and quantify the concentration of a larger number of materials. The proposed method, named multi-material decomposition (MMD), was used to develop two image analysis algorithms. The first was virtual unenhancement (VUE), which digitally removes the effect of contrast agents from contrast-enhanced dual-energy CT exams. VUE has the ability to reduce patient dose and improve clinical workflow, and can be used in a number of clinical applications such as CT urography and CT angiography. The second algorithm developed was liver-fat quantification (LFQ), which accurately quantifies the fat concentration in the liver from dual-energy CT exams. LFQ can form the basis of a clinical application targeting the diagnosis and treatment of fatty liver disease. Using image data collected from a cohort consisting of 50 patients and from phantoms, the application of MMD to VUE and LFQ yielded quantitatively accurate results when compared against gold standards. Furthermore, consistent results were obtained across all phases of imaging (contrast-free and contrast-enhanced). This is of particular importance since most clinical protocols for abdominal imaging with CT call for multi-phase imaging. We conclude that MMD can successfully form the basis of a number of dual-energy CT image analysis algorithms, and has the potential to improve the clinical utility

  12. TRIAGE OF PATIENTS TO ANGIOGRAPHY FOR DETECTION OF AORTIC RUPTURE AFTER BLUNT CHEST TRAUMA - COST-EFFECTIVENESS ANALYSIS OF USING CT

    NARCIS (Netherlands)

    HUNINK, MGM; BOS, JJ

    OBJECTIVE. The purpose of this study was to evaluate the cost-effectiveness of dynamic chest CT, compared with plain chest radiography and immediate angiography, in deciding when angiography should be performed in hemodynamically stable patients with suspected aortic rupture after blunt chest

  13. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  14. Multi-detector row computed tomography and blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, Mariano; Pinto, Antonio; Pedrosa, Ivan; Sparano, Amelia; Romano, Luigia

    2008-01-01

    Blunt chest trauma is a significant source of morbidity and mortality in industrialized countries. The clinical presentation of trauma patients varies widely from one individual to another and ranges from minor reports of pain to shock. Knowledge of the mechanism of injury, the time of injury, estimates of motor vehicle accident velocity and deceleration, and evidence of associated injury to other systems are all salient features to provide for an adequate assessment of chest trauma. Multi-detector row computed tomography (MDCT) scanning and MDCT-angiography are being used more frequently in the diagnosis of patients with chest trauma. The high sensitivity of MDCT has increased the recognized spectrum of injuries. This new technology can be regarded as an extremely valuable adjunct to physical examination to recognize suspected and unsuspected blunt chest trauma

  15. Use of spiral CT angiography to judge central pulmonary vascular involvement from lung cancer

    International Nuclear Information System (INIS)

    Tan Qunyou; Zhao Shaohong; Wang Fangze; Cai Zulong

    2000-01-01

    Objective: To evaluate the accuracy of spiral CT angiography (SCTA) in judging central pulmonary vascular involvement from lung cancer located in the hilum and correlate the resultant images with pathologic and surgical findings. Methods: SCTA was done in 33 patients who were preoperatively diagnosed as having lung carcinoma located in the hilum. Contrast medium was injected at a rate of 3 ml/sec with a power injector. The delay time was from 20 to 25 seconds. The pitch was 1 with 3 mm-collimation. Images of central pulmonary arteries and veins were reconstructed with shaded surface display (SSD), maximum intensity projection (MIP), curved planar reformation (CPR), and multi-planar reformation (MPR). Then the relation between tumor and vessels was assessed prospectively on both 3 mm interval axial CT and SCTA images with comparison to subsequent pathologic or surgical findings. Results: (1) In showing the integrity of central pulmonary arteries and veins, images reconstructed by different ways of SCTA had different strong and weak points. (2) The grading standard in this study, with which the relation between vessels and tumor was judged, reflected the basic and common characters of central pulmonary vascular involvement by tumor located in the hilum. compared with axial CT images, SCTA was more accurate in judging the relation between central pulmonary vessels and tumor, and the correlation of SCTA imaging features with pathological patterns and surgical findings was better than that of axial CT images, P < 0.05 and P < 0.0001, respectively. Conclusion: It was feasible to show the relation between central pulmonary vessel and lung cancer located in the hilum with SCTA. And the accuracy of judging the vascular involvement with SCTA was higher than that with axial CT

  16. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  18. Renal computed angiography. Part I: Renal CT phlebography. Renal veins variants

    International Nuclear Information System (INIS)

    Al-Amin, M.; Krupev, M.; Hadjidekov, V.; Plachkov, I.

    2012-01-01

    The changing trend in renal surgery, transplantation and minimal invasive urology implies preprocedure evaluation of renal veins. Development of imaging methods offers new possibilities for venographic visualization. The goal of this study is to present authors experience in visualization of renal veins using 64 MDCT and to evaluate the utility in assessments of their variants. 128 patients (68 females and 60 males, mean age 53,3) with urological complaints underwent 64MDCT examination including CT angiography. Contrast enhancement includes 3-4ml/sec injection flow of 90 ml contrast medium followed by 20 ml saline at the same rate. In 23 out of 128 examined patients some of the common variants of the renal vein is found. 64 MDCT angiography visualize very well renal veins and becomes method of choice in preoperative assessment of renal vein anatomy. (authors)

  19. A new timing detector for the CT-PPS project

    Energy Technology Data Exchange (ETDEWEB)

    Arcidiacono, R. [INFN – Torino (Italy); Università del Piemonte Orientale (Italy)

    2017-02-11

    The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (∼20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.

  20. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  1. A anatomic evaluation of the lateral femoral circumflex artery system by using Multi detector-row CT

    International Nuclear Information System (INIS)

    Haraguchi, Kazunari; Kadota, Satoshi; Hosaka, Yoshiaki

    2010-01-01

    Flaps that are pedicled by perforators of the lateral femoral circumflex artery (LFCA) system have many advantages, including the transplantation of large and reliable skin with long pedicles and a large diameter, and little invasion of the donor sites. However, preoperative planning has been difficult because the perforators have many anatomic variations. We used multi detector-row CT for anatomical evaluation of the lateral femoral circumflex artery system. The patterns of LFCA from the main vessels were classified into three types and vessels coursing toward the lateral thigh region were classified into three groups. The distance from the anterior superior iliac spine to the lateral femoral circumflex artery showed no significant difference between men and women. We were able to evaluate vessels with a 2-mm diameter in the lateral femoral circumflex artery system, indicating that accurate evaluation and low invasive examination of the lateral femoral circumflex artery system, including the perforator area, can be achieved by adjusting the image conditions and the injection rate of the contrast dye. (author)

  2. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  3. Maximum-intensity-projection CT angiography for evaluating head and neck tumors. Usefulness of helical CT and auto bone masking method

    International Nuclear Information System (INIS)

    Sakai, Osamu; Nakashima, Noriko; Ogawa, Chiaki; Shen, Yun; Takata, Yasunori; Azemoto, Shougo.

    1994-01-01

    Angiographic images of 10 adult patients with head and neck tumors were obtained by helical computed tomography (CT) using maximum intensity projection (MIP). In all cases, the vasculature of the head and neck region was directly demonstrated. In the head and neck, bone masking is a more important problem than in other regions. We developed an effective automatic bone masking method (ABM) using 2D/3D connectivity. Helical CT angiography with MIP and ABM provided accurate anatomic depiction, and was considered to be helpful in preoperative evaluation of head and neck tumors. (author)

  4. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  5. Arteriovenous fistula complicating iliac artery pseudo aneurysm: diagnosis by CT angiography.

    Science.gov (United States)

    Huawei, L; Bei, D; Huan, Z; Zilai, P; Aorong, T; Kemin, C

    2002-01-01

    Fistula formation to the inferior vena cava is a rare complication of aortic aneurysm which is often misdiagnosed clinically. In one hundred of reported arteriocaval fistulae, none was originating from the right common iliac artery. We report a case of ileo-caval fistula due to a iatrogenic pseudoaneurysm. High resolution 3D imaging using breath-hold CT angiography is highly specific in identifying the location, extent of the aortocaval fistula as well as the neighbouring anatomic structures.

  6. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  7. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria; Duka, Ejona [University of Insubria, Interventional Radiology, Department of Radiology (Italy); Radaelli, Alessandro [Philips Healthcare (Netherlands); Rivolta, Nicola; Piffaretti, Gabriele [University of Insubria, Vascular Surgery Department (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [University of Insubria, Interventional Radiology, Department of Radiology (Italy)

    2016-01-15

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

  8. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    International Nuclear Information System (INIS)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro; Rivolta, Nicola; Piffaretti, Gabriele; Carrafiello, Gianpaolo

    2016-01-01

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration

  9. Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

    Science.gov (United States)

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G.

    2015-01-01

    In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values on a CT image (ie, CT numbers), depending on the mass density of the material. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT, an additional attenuation measurement is obtained with a second x-ray spectrum (ie, a second “energy”), allowing the differentiation of multiple materials. Alternatively, this allows quantification of the mass density of two or three materials in a mixture with known elemental composition. Recent advances in the use of energy-resolving, photon-counting detectors for CT imaging suggest the ability to acquire data in multiple energy bins, which is expected to further improve the signal-to-noise ratio for material-specific imaging. In this review, the underlying motivation and physical principles of dual- or multi-energy CT are reviewed and each of the current technical approaches is described. In addition, current and evolving clinical applications are introduced. © RSNA, 2015 PMID:26302388

  10. Initial clinical experience with dual-layer detector spectral CT in patients with acute intracerebral haemorrhage: A single-centre pilot study.

    Directory of Open Access Journals (Sweden)

    Soo Buem Cho

    Full Text Available The purpose of this study was to investigate the clinical feasibility of spectral analyses using dual-layer detector spectral computed tomography (CT in acute intracerebral haemorrhage (ICH.We retrospectively reviewed patients with acute ICH who underwent CT angiography on a dual-layer detector spectral CT scanner. A spectral data analysis was performed to detect contrast enhancement in or adjacent to acute ICH by using spectral image reconstructions including monoenergetic (MonoE, virtual noncontrast (VNC, and iodine overlay fusion images. We also acquired a spectral plot to assess material differentiation within lesions.Among the 30 patients, the most common cause of acute ICH was chronic hypertension (18/30, 60% followed by trauma (5/30, 16.7%, brain tumour (3/30, 10%, Moyamoya disease (2/30, 6.7%, and haemorrhagic diathesis from anticoagulation therapy (2/30, 6.7%. Of 30 patients, 13 showed suboptimal iodine suppression in the subcalvarial spaces on VNC images compared with true noncontrast images. The CT angiographic spot sign within the acute ICH was detected in four patients (4/30, 13.3%. All three tumours were metastatic and included lung cancer (n = 2 and hepatocellular carcinoma (n = 1 which showed conspicuous delineation of an enhancing tumour portion in the spectral analysis. Spectral analyses allowed the discrimination of acute haemorrhage and iodine with enhanced lesion visualization on the MonoE images obtained at lower keVs (less than 70 keV and spectral plot.Even though the image quality of VNC is perceived to be inferior, it is feasible to evaluate acute ICH in clinical settings using dual-layer detector spectral CT. The MonoE images taken at lower keVs were useful for depicting contrast enhancing lesion, and spectral plot might be helpful for material differentiation in patients with acute ICH.

  11. Initial clinical experience with dual-layer detector spectral CT in patients with acute intracerebral haemorrhage: A single-centre pilot study.

    Science.gov (United States)

    Cho, Soo Buem; Baek, Hye Jin; Ryu, Kyeong Hwa; Moon, Jin Il; Choi, Bo Hwa; Park, Sung Eun; Bae, Kyungsoo; Jeon, Kyung Nyeo; Kim, Dong Wook

    2017-01-01

    The purpose of this study was to investigate the clinical feasibility of spectral analyses using dual-layer detector spectral computed tomography (CT) in acute intracerebral haemorrhage (ICH). We retrospectively reviewed patients with acute ICH who underwent CT angiography on a dual-layer detector spectral CT scanner. A spectral data analysis was performed to detect contrast enhancement in or adjacent to acute ICH by using spectral image reconstructions including monoenergetic (MonoE), virtual noncontrast (VNC), and iodine overlay fusion images. We also acquired a spectral plot to assess material differentiation within lesions. Among the 30 patients, the most common cause of acute ICH was chronic hypertension (18/30, 60%) followed by trauma (5/30, 16.7%), brain tumour (3/30, 10%), Moyamoya disease (2/30, 6.7%), and haemorrhagic diathesis from anticoagulation therapy (2/30, 6.7%). Of 30 patients, 13 showed suboptimal iodine suppression in the subcalvarial spaces on VNC images compared with true noncontrast images. The CT angiographic spot sign within the acute ICH was detected in four patients (4/30, 13.3%). All three tumours were metastatic and included lung cancer (n = 2) and hepatocellular carcinoma (n = 1) which showed conspicuous delineation of an enhancing tumour portion in the spectral analysis. Spectral analyses allowed the discrimination of acute haemorrhage and iodine with enhanced lesion visualization on the MonoE images obtained at lower keVs (less than 70 keV) and spectral plot. Even though the image quality of VNC is perceived to be inferior, it is feasible to evaluate acute ICH in clinical settings using dual-layer detector spectral CT. The MonoE images taken at lower keVs were useful for depicting contrast enhancing lesion, and spectral plot might be helpful for material differentiation in patients with acute ICH.

  12. Dual energy CT at the synchrotron: A piglet model for neurovascular research

    International Nuclear Information System (INIS)

    Schueltke, Elisabeth; Kelly, Michael E.; Nemoz, Christian; Fiedler, Stefan; Ogieglo, Lissa; Crawford, Paul; Paterson, Jessica; Beavis, Cole; Esteve, Francois; Brochard, Thierry; Renier, Michel; Requardt, Herwig; Dallery, Dominique; Le Duc, Geraldine; Meguro, Kotoo

    2011-01-01

    Background: Although the quality of imaging techniques available for neurovascular angiography in the hospital environment has significantly improved over the last decades, the equipment used for clinical work is not always suited for neurovascular research in animal models. We have previously investigated the suitability of synchrotron-based K-edge digital subtraction angiography (KEDSA) after intravenous injection of iodinated contrast agent for neurovascular angiography in radiography mode in both rabbit and pig models. We now have used the KEDSA technique for the acquisition of three-dimensional images and dual energy CT. Materials and methods: All experiments were conducted at the biomedical beamline ID 17 of the European Synchrotron Radiation Facility (ESRF). A solid state germanium (Ge) detector was used for the acquisition of image pairs at 33.0 and 33.3 keV. Three-dimensional images were reconstructed from an image series containing 60 single images taken throughout a full rotation of 360 o . CT images were reconstructed from two half-acquisitions with 720 projections each. Results: The small detector field of view was a limiting factor in our experiments. Nevertheless, we were able to show that dual energy CT using the KEDSA technique available at ID 17 is suitable for neurovascular research in animal models.

  13. Dual energy CT at the synchrotron: a piglet model for neurovascular research.

    Science.gov (United States)

    Schültke, Elisabeth; Kelly, Michael E; Nemoz, Christian; Fiedler, Stefan; Ogieglo, Lissa; Crawford, Paul; Paterson, Jessica; Beavis, Cole; Esteve, Francois; Brochard, Thierry; Renier, Michel; Requardt, Herwig; Dallery, Dominique; Le Duc, Geraldine; Meguro, Kotoo

    2011-08-01

    Although the quality of imaging techniques available for neurovascular angiography in the hospital environment has significantly improved over the last decades, the equipment used for clinical work is not always suited for neurovascular research in animal models. We have previously investigated the suitability of synchrotron-based K-edge digital subtraction angiography (KEDSA) after intravenous injection of iodinated contrast agent for neurovascular angiography in radiography mode in both rabbit and pig models. We now have used the KEDSA technique for the acquisition of three-dimensional images and dual energy CT. All experiments were conducted at the biomedical beamline ID 17 of the European Synchrotron Radiation Facility (ESRF). A solid state germanium (Ge) detector was used for the acquisition of image pairs at 33.0 and 33.3 keV. Three-dimensional images were reconstructed from an image series containing 60 single images taken throughout a full rotation of 360°. CT images were reconstructed from two half-acquisitions with 720 projections each. The small detector field of view was a limiting factor in our experiments. Nevertheless, we were able to show that dual energy CT using the KEDSA technique available at ID 17 is suitable for neurovascular research in animal models. Copyright © 2010. Published by Elsevier Ireland Ltd.

  14. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    Science.gov (United States)

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  15. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  16. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  17. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  18. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  19. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    Directory of Open Access Journals (Sweden)

    Marwa Sayed Meshaal

    Full Text Available Infective endocarditis (IE is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs. These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention.The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%. Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32% had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%. The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.Routine brain CT/CTA resulted in changes in the treatment plan in a significant

  20. Efficacy of 'fine' focal spot imaging in CT abdominal angiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Lawrence Chia Wei; Devapalasundaram, Ashwini; Ardley, Nicholas [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing, and Health Sciences, Victoria (Australia); Buchan, Kevin [Phillips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Huynh, Minh [RMIT University, School of Mathematical and Geospatial Sciences, Victoria (Australia)

    2014-12-15

    To assess the efficacy of fine focal spot imaging in calcification beam-hardening artefact reduction and vessel clarity on CT abdominal angiography (CTAA). Adult patients of any age and gender who presented for CTAA were included. Thirty-nine patients were examined with a standard focal spot size (SFSS) of 1 x 1 mm in the first 3 months while 31 consecutive patients were examined with a fine focal spot size (FFSS) of 1 x 0.5 mm in the following 3 months. Vessel clarity and calcification beam-hardening artefacts of the abdominal aorta, celiac axis, superior mesenteric artery, inferior mesenteric artery, renal arteries, and iliac arteries were assessed using a 5-point grading scale by two blinded radiologists randomly. Cohen's Kappa test indicated that on average, there was substantial agreement among reviewers for vessel wall clarity and calcification artefact grading. Mann-Whitney test showed that there was a significant difference between the two groups, with FFSS performing significantly better for vessel clarity (U, 6481.50; p < 0.001; r, 0.73) and calcification artefact reduction (U, 1916; p < 0.001; r, 0.77). Fine focus CT angiography produces images with better vessel wall clarity and less vessel calcification beam-hardening artefact. (orig.)

  1. Clinical application of three-dimensional spiral CT cerebral angiography with volume rendering

    International Nuclear Information System (INIS)

    Duan Shaoyin; Huang Xi'en; Kang Jianghe; Zhang Dantong; Lin Qingchi; Cai Guoxiang; Xu Meixin; Pang Ruilin

    2002-01-01

    Objective: To study the methodology and assess the clinical value of three-dimensional CT angiography (3D-CTA) with volume rendering (VR) in cerebral vessels. Methods: Sixty-two patients were examined by means of 3D-CTA with volume rendering. VR was used in the reconstruction of 3D images, and the demonstration of normal vessels and vascular lesions were particularly analyzed. At the same time, comparisons were made between the images of VR and SSD, MIP, and also between the diagnosis of VR-CTA and DSA or postoperative results. Results: In VR images, cerebral vessel routes and vessel cavities were showed clearly, while the relationship among vascular lesions, surrounding vessels, and neighboring structure was distinguished. 50 cases (80.6%) were found positive, 48 of which were correct and 2 were false-positive compared with DSA or postoperative results. The accurate rate of diagnosis was 96.0%. There was no obvious difference in showing the cerebral vessel among the images of VR, SSD and MIP (P > 0.25). Conclusion: Three-dimensional CT cerebral angiography with VR is a new noninvasive effective method. It can even partly replace the DSA. The 3D-images have the characteristics of showing the cerebral vascular cavity and overlapped vessels without cutting the skull

  2. Flat-detector computed tomography in diagnostic and interventional neuroradiology

    International Nuclear Information System (INIS)

    Struffert, T.; Doerfler, A.

    2009-01-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with film-screen and phosphor luminescence, radiography flat detector technology is now widely accepted for neuroangiographic imaging. Especially flat-detector computed tomography (FD-CT), which uses rotational C-arm mounted flat-panel detector technology, is capable of volumetric imaging with a high spatial resolution. As ''angiographic CT'' FD-CT may be helpful in many diagnostic and neurointerventional procedures, e.g. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolization of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angiography suite FD-CT allows rapid visualization of periprocedural hemorrhaging and may thus improve rapid complication management without the need of patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single modality. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. Imaging of the temporal bone may also develop into an important field of FD-CT. This paper briefly reviews the technical principles of FD technology and the potential applications in diagnostic and interventional neuroradiology. (orig.) [de

  3. Laparoscopic resection aided by preoperative 3-D CT angiography for rectosigmoid colon cancer associated with a horseshoe kidney: A case report.

    Science.gov (United States)

    Maeda, Yoshiaki; Shinohara, Toshiki; Nagatsu, Akihisa; Futakawa, Noriaki; Hamada, Tomonori

    2014-11-01

    We herein report a case of laparoscopic high anterior resection with D3 lymph node dissection for rectosigmoid colon cancer with a horseshoe kidney. A 65-year-old Japanese man referred to our hospital for rectosigmoid colon cancer was found to have a horseshoe kidney on a CT scan. On 3-D CT angiography, an aberrant renal artery was visualized feeding the renal isthmus that arises from the aorta just below the root of the inferior mesenteric artery (IMA). Laparoscopic anterior rectal resection with D3 lymph node dissection was performed. During the operation, the IMA, left ureter, left gonadal vessels and hypogastric nerve plexus could be seen passing over the horseshoe kidney isthmus. With the aid of preoperative 3-D CT angiography, the root of the IMA was identified on the temporal side of the isthmus and divided safely just above the hypogastric nerve. As a horseshoe kidney is often accompanied by aberrant renal arteries and/or abnormal running of the ureter, 3-D CT angiography is useful for determining the location of these structures and avoiding intraoperative injury. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  4. Detection of thin wall regions of unruptured cerebral aneurysms by ECG synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 slices per rotation CT

    International Nuclear Information System (INIS)

    Fujita, Shigekiyo

    2004-01-01

    The objective of this study was to evaluate the capability of electrocardiogram (ECG) synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 sequence MD-CT to detect weak portions of unruptured cerebral aneurysm. 4D-CT angiography of unruptured cerebral aneurysms was performed on 26 patients, 28 cerebral aneurysms, using 16 sequence MD-CT (GE, HiLight Matrix II). Contrast material of iodine (300 mg/ml) was injected over 30 sec period into the ante-cubital vein with a rate of 0.06 ml/Kg/sec. ECG synchronous reconstruction images (10 images at intervals of 10% between R-R of ECG) were generated (GE, Workstation Advantage 4.1). After careful inspection of the wall motion of an aneurysm from many aspects, cine images were made from several directions. Acquisition of data required 9 seconds, total volume data were generated within 15 minutes, and ECG synchronous reconstruction image processing was performed in about 5 minutes. Animation creation for one direction was completed within one minute. Even in 3-mm aneurysms, changes of its form and size within a heartbeat were fully observed. Timing of maximum and minimum sizes were also recognized. The pulsatile changes and nipple extent, bleb, daughter, and dome of aneurysms were well visualized. The projecting motion of the pulsatory enlargement of nipple was detected in nine cases, and definite increases in bleb sizes were detected in five cases. Since the easily reptured thin walled portion of a cerebral aneurysm can be recognized by this method, 4D-CT angiography is likely to become indispensable in judging how to cope with unruptured cerebral aneurysms, in deciding whether to operate or observe. (author)

  5. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias; Scholz, Bernhard; Royalty, Kevin

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  6. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  7. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  8. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  9. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  10. CT-angiography source images indicate less fatal outcome despite coma of patients in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Pallesen, Lars P; Khomenko, Andrei; Dzialowski, Imanuel; Barlinn, Jessica; Barlinn, Kristian; Zerna, Charlotte; van der Hoeven, Erik Jrj; Algra, Ale; Kapelle, L Jaap; Michel, Patrik; Bodechtel, Ulf; Demchuk, Andrew M; Schonewille, Wouter; Puetz, Volker

    2017-02-01

    Background Coma is associated with poor outcome in patients with basilar artery occlusion. Aims We sought to assess whether the posterior circulation Acute Stroke Prognosis Early CT Score and the Pons-Midbrain Index applied to CT angiography source images predict the outcome of comatose patients in the Basilar Artery International Cooperation Study. Methods Basilar Artery International Cooperation Study was a prospective, observational registry of patients with acute basilar artery occlusion with 48 recruiting centers worldwide. We applied posterior circulation Acute Stroke Prognosis Early CT Score and Pons-Midbrain Index to CT angiography source images of Basilar Artery International Cooperation Study patients who presented with coma. We calculated adjusted risk ratios to assess the association of dichotomized posterior circulation Acute Stroke Prognosis Early CT Score (≥8 vs. International Cooperation Study registry, CT angiography source images were available for review in 158 patients. Among these, 78 patients (49%) presented with coma. Compared to non-comatose patients, comatose patients were more likely to die (risk ratios 2.34; CI 95% 1.56-3.52) and less likely to have a favourable outcome (risk ratios 0.44; CI 95% 0.24-0.80). Among comatose patients, a Pons-Midbrain Index < 3 was related to reduced mortality (adjusted RR 0.66; 95% CI 0.46-0.96), but not to favourable outcome (adjusted RR 1.19; 95% CI 0.39-3.62). Posterior circulation Acute Stroke Prognosis Early CT Score dichotomized at ≥ 8 vs. <8 was not significantly associated with death (adjusted RR 0.70; 95% CI 0.46-1.05). Conclusion In comatose patients with basilar artery occlusion, the extent of brainstem ischemia appears to be related to mortality but not to favourable outcome.

  11. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  12. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Ferencik, Maros; Lisauskas, Jennifer B.; Cury, Ricardo C.; Hoffmann, Udo; Abbara, Suhny; Achenbach, Stephan; Karl, W. Clem; Brady, Thomas J.; Chan, Raymond C.

    2006-01-01

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm 2 and -0.2 ± 2.2 mm 2 (p 2 , respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  13. The Road to the Common PET/CT Detector

    Science.gov (United States)

    Nassalski, Antoni; Moszynski, Marek; Szczesniak, Tomasz; Wolski, Dariusz; Batsch, Tadeusz

    2007-10-01

    Growing interest in the development of dual modality positron emission/X-rays tomography (PET/CT) systems prompts researchers to face a new challenge: to acquire both the anatomical and functional information in the same measurement, simultaneously using the same detection system and electronics. The aim of this work was to study a detector consisting of LaBr3, LSO or LYSO pixel crystals coupled to an avalanche photodiode (APD). The measurements covered tests of the detectors in PET and CT modes, respectively. The measurements included the determination of light output, energy resolution, the non-proportionality of the light yield and the time resolution for 511 keV annihilation quanta; analysis also included characterizing the PET detector, and determining the dependence of counting rate versus mean current of the APD in the X-ray detection. In the present experiment, the use of counting and current modes in the CT detection increases the dynamic range of the measured dose of X-rays by a factor of 20, compared to the counting mode alone.

  14. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  15. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    Energy Technology Data Exchange (ETDEWEB)

    Teksam, Mehmet E-mail: mehmetteksam@yahoo.com; McKinney, Alexander; Truwit, Charles L

    2004-12-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass.

  16. Multi-slice CT angiography in evaluation of extracranial-intracranial bypass

    International Nuclear Information System (INIS)

    Teksam, Mehmet; McKinney, Alexander; Truwit, Charles L.

    2004-01-01

    Multi-slice CT (MSCT) scanners provided significant improvement in vascular applications. In this study, our purpose was to determine the clinical utility of MSCTA in evaluation of extracranial-intracranial (EC-IC) bypass patency. Eleven (4 men and 7 women; mean age, 46 years; age range, 19-68 years) consecutive patients who underwent MSCTA and DSA after EC-IC bypass surgery were evaluated retrospectively. All patients underwent DSA within 3 weeks of MSCTA. The indications for EC-IC bypass were severe stenosis or occlusion of intracranial arteries in seven patients and therapeutic occlusion of intracranial artery for unclippable giant aneurysm in four patients. Ten patients underwent superficial temporal artery (STA)-middle cerebral artery (MCA) bypass and one patient underwent occipital artery-posterior cerebral artery (PCA) bypass. Eight STA-MCA bypasses in six patients were patent on MSCTA which were confirmed on DSA. Two MSCTA bypasses and one occipital artery-posterior cerebral artery (PCA) bypass were occluded in three patients on MSCTA and DSA. In one patient, minimal stenosis of the STA-MCA bypass was identified on MSCTA and DSA. In 1 patient, STA-MCA bypass was not well seen on MSCTA and suspected for occlusion. DSA identified the occlusion of bypass on this patient. MSCTA seems to be a very promising noninvasive technique in evaluation of EC-IC bypass

  17. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    Energy Technology Data Exchange (ETDEWEB)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin [Istanbul University, Department of Radiology, Cerrahpasa Medical Faculty (Turkey); Senyuz, Osman F. [Istanbul University, Department of Paediatric Surgery, Cerrahpasa Medical Faculty (Turkey); Dervisoglu, Sergulen [Istanbul University, Department of Pathology, Cerrahpasa Medical Faculty (Turkey)

    2006-11-15

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  18. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    International Nuclear Information System (INIS)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin; Senyuz, Osman F.; Dervisoglu, Sergulen

    2006-01-01

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  19. Role of coronary CT angiography in asymptomatic patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Kamimura, Munehiro; Moroi, Masao; Hiroe, Michiaki; Isobe, Mitsuaki

    2012-01-01

    Diabetic patients with coronary artery disease are often asymptomatic, making appropriate care of such patients difficult. The purpose of this study was to investigate the prevalence of coronary lesions in asymptomatic diabetic patients. Coronary computed tomography (CT) angiography was performed in 120 consecutive diabetic patients (90 of whom were men, mean age 65, mean HbA1c 7.2%). Images from patients whose coronary artery calcium scores (CAC scores) were less than 400 were subjected to stenosis and plaque analysis. Significant stenosis was defined as coronary artery stenosis >70%. High-risk plaque was defined as plaque having both a CT density <30 Hounsfield Units (HU) and showing positive remodeling. Significant stenoses were identified in 30.5% of the patients. High-risk plaques were identified in 17.1% of the patients. Less than half of the high-risk plaques were obstructive plaques. There was a statistically significant association between significant stenosis and high-risk plaque by chi-square test (P=0.022). We found significant stenosis even in patients whose CAC score =0 at a rate of 5.0%. Using univariate logistic-regression analysis, we found that coronary risk factors associated with significant stenosis and high-risk plaque were dyslipidemia (P=0.033) and current smoking (P=0.030), respectively. We report for the first time, the prevalence of high-risk plaques in the arteries of patients with asymptomatic diabetes, as assessed by coronary CT angiography. (author)

  20. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    International Nuclear Information System (INIS)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing; Zheng, Xiangpeng; Chen, Yan; Lv, Fangzhen

    2013-01-01

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  1. The technique advantages of 16-detector multic-slice spiral CT in evaluating combined pulmonary and deep vein thromboembolism

    International Nuclear Information System (INIS)

    Xia Shuang; Qi Ji; Lei Xinwei; Wen Lianqing; Li Yiming; Liu Jisheng

    2004-01-01

    Objective: To study the scanning technique of 16-detector multic-slice spiral CT(MSCT) for combined pulmonary artery and deep vein of lower limb in pulmonary thromboembolism (PE) patients. Methods: Forty suspected pulmonary thromboembolism patients were performed both pulmonary artery angiography (CTA) and indirect deep vein venography (CTV) on 16-detector MSCT. The parameters of the latter as following: total contrast volume 120-150 ml, injection rate 4.0-4.5 ml/s (from antecubital vein), delay time 4.0 for CTA 20-23 s, CTV 120-180 s, collimation for CTA 1.25 mm and 0.625 mm, CTV 2.5 mm, scan range of CTV: from popliteal vein to the level of bilateral renal vein into the inferior vena cava. Postprocessing include MPR, MIP, and VR. The test was used to analyzed the images. Results: Twenty five patients had both pulmonary thromboembolism (PE) and deep vein thromboembolism (DVT), 8 patients had only DVT, 2 had only PE, and 5 had neither. There was no difference between different collimation in depicting thrombus. The CT value number of enhanced pulmonary artery and lower deep vein was obviously higher than the thrombus. The value of MPR, MIP, VR for PE was 100%, 100%, and 65%, The value of MPR, MIP, VR for DVT is 100%, 60%, and 50%. Conclusion: The technique of combined pulmonary CTA and deep vein CTV of 16-detector MSCT will provide a new modality for pulmonary thromboembolism patients. (author)

  2. Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

    NARCIS (Netherlands)

    Elattar, Mustafa A.; Vink, Leon W.; van Mourik, Martijn S.; Baan, Jan; Vanbavel, Ed T.; Planken, R. Nils; Marquering, Henk A.

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the

  3. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols

    International Nuclear Information System (INIS)

    Neefjes, Lisan A.; Kate, Gert-Jan R. ten; Rossi, Alexia; Nieman, Koen; Papadopoulou, Stella L.; Dharampal, Anoeshka S.; Dedic, Admir; Feyter, Pim J. de; Mollet, Nico R.; Genders, Tessa S.S.; Hunink, M.G.M.; Schultz, Carl J.; Weustink, Annick C.; Dijkshoorn, Marcel L.; Straten, Marcel van; Cademartiri, Filippo; Krestin, Gabriel P.

    2013-01-01

    To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose. circle 128-slice dual-source CT coronary angiography offers several different acquisition protocols. (orig.)

  4. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  5. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [German] Die periphere arterielle Verschlusskrankheit (PAVK) ist eine wesentliche Komplikation des Diabetes mellitus und stellt aufgrund ausgepraegter Gefaessverkalkungen eine diagnostische

  6. Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography.

    Directory of Open Access Journals (Sweden)

    Richard Nolz

    Full Text Available To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction.The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated.Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09, and in venous sets of 73.3 versus 79.4 (p = 0.15, respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01. Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase.Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.

  7. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  8. Integrated circuit detector technology in abdominal CT: added value in obese patients.

    Science.gov (United States)

    Morsbach, Fabian; Bickelhaupt, Sebastian; Rätzer, Susan; Schmidt, Bernhard; Alkadhi, Hatem

    2014-02-01

    The purpose of this article was to assess the effect of an integrated circuit (IC) detector for abdominal CT on image quality. In the first study part, an abdominal phantom was scanned with various extension rings using a CT scanner equipped with a conventional discrete circuit (DC) detector and on the same scanner with an IC detector (120 kVp, 150 effective mAs, and 75 effective mAs). In the second study part, 20 patients were included who underwent abdominal CT both with the IC detector and previously at similar protocol parameters (120 kVp tube current-time product and 150 reference mAs using automated tube current modulation) with the DC detector. Images were reconstructed with filtered back projection. Image quality in the phantom was higher for images acquired with the IC compared with the DC detector. There was a gradually increasing noise reduction with increasing phantom sizes, with the highest (37% in the largest phantom) at 75 effective mAs (p < 0.001). In patients, noise was overall significantly (p = 0.025) reduced by 6.4% using the IC detector. Similar to the phantom, there was a gradual increase in noise reduction to 7.9% in patients with a body mass index of 25 kg/m(2) or lower (p = 0.008). Significant correlation was found in patients between noise and abdominal diameter in DC detector images (r = 0.604, p = 0.005), whereas no such correlation was found for the IC detector (r = 0.427, p = 0.060). Use of an IC detector in abdominal CT improves image quality and reduces image noise, particularly in overweight and obese patients. This noise reduction has the potential for dose reduction in abdominal CT.

  9. Three-dimensional CT angiography in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Nakamura, Takeshi; Yoneda, Shigeru

    1995-01-01

    We reported the usefulness of three dimensional CT angiography (3 DCTA) in cerebrovascular disease. Twenty two of twenty three intracerebral aneurysms were visualized in 3 DCTA. 3 DTPA was especially useful for the evaluation of posterior-projection anterior communicating arteries and the distinction between a carotid-posterior communicating aneurysm and an infundibular dilatation. An anterior-projection carotid bifurcation aneurysm, which we missed in DSA, was visualized clearly in 3 DCTA. Stenotic cervical carotid artery lesions were well evaluated in 3 DCTA, including ulceration. 3 DCTA was not so useful for evaluation of intracranial artery stenosis. 3 DCTA was useful as a non-invasive method to evaluate cerebrovascular diseases. (author)

  10. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

    International Nuclear Information System (INIS)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara; Sasaki, Tsukasa; Katoh, Chietsugu; Shirato, Hiroki

    2014-01-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against 15 O-H 2 O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P CT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  11. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  12. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  13. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  14. Multi-detector CT-colonography in inflammatory bowel disease: Prospective analysis of CT-findings to high-resolution video colonoscopy

    International Nuclear Information System (INIS)

    Andersen, Kjel; Vogt, Christoph; Blondin, Dirk; Beck, Andreas; Heinen, Wolfram; Aurich, Volker; Haeussinger, Dieter; Moedder, Ulrich; Cohnen, Mathias

    2006-01-01

    Aim: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). Materials and methods: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1 mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. Results: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. Conclusion: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity

  15. Prevalence of Congenital Coronary Artery Anomalies and Variants in 2697 Consecutive Patients Using 64-Detector Row Coronary CTAngiography

    International Nuclear Information System (INIS)

    Shabestari, Abbas Arjmand; Akhlaghpoor, Shahram; Tayebivaljozi, Reza; Fattahi Masrour, Farzaneh

    2012-01-01

    Coronary artery anomalies are not common, but could be very serious. This study determines the frequency of coronary anomalies and normal variants by multi-detector-row computed tomography (MDCT). The results of cardiac MDCT study in 2697 consecutive patients were analyzed retrospectively. Acquisition was performed by a 64-detector row CT machine. Imaging results were assessed by experienced radiologists. Myocardial bridging was by far the most frequent coronary variant (n = 576, 21.3%). Eighty-three subjects (3.1%) showed other coronary anomalies and variants. Anomalies of origination and course of the left main coronary artery (LMCA) were detected in 1.09% of the subjects. The frequency of these anomalies in the right coronary artery (RCA), left circumflex artery (LCx), left anterior descending artery (LAD), posterior descending artery (PDA) and obtuse marginal (OM) artery were 1.24%, 0.33%, 0.1%, 0.07% and 0.03%, respectively. The single coronary pattern was seen in 0.18% and coronary fistulas in 0.07%. Based on the fact that coronary CT-angiography using MDCT can display different coronary anomalies, this study shows similar results to other reports on the subject. Future advances in the performance of CT machines will further improve the quality of CT-based cardiac imaging

  16. Multi-detector computed tomography (MDCT imaging of cardiovascular effects of pulmonary embolism: What the radiologists need to know

    Directory of Open Access Journals (Sweden)

    Mohamed Aboul-fotouh E. Mourad

    2017-09-01

    Full Text Available Background: Patients with pulmonary embolism have high mortality and morbidity rate due to right heart failure and circulatory collapse leading to sudden death. Multi-detector computed tomography MDCT can efficiently evaluate the cardiovascular factors related to pulmonary embolism. Objectives: To evaluate the diagnostic accuracy of multi-detector computed tomography (MDCT in differentiation of between sever and non-severe pulmonary embolism groups depending on the associated cardiovascular parameters and create a simple reporting system. Patients & methods: Prospective study contained 145 patients diagnosed clinically pulmonary embolism. All patients were examined by combined electrocardiographically gated computed tomography pulmonary angiography-computed tomography venography (ECG-CTPA-CTV using certain imaging criteria in a systematic manner. Results: Our study revealed 95 and 55 non-severe and severe pulmonary embolism groups respectively. Many cardiovascular parameters related to pulmonary embolism shows significant p value and can differentiate between sever and non-severe pulmonary embolism patients include pulmonary artery diameter, intraventricular septum flattening, bowing, superior vena cava and Azygos vein diameters, right and left ventricular diameters. Conclusion: Multi-detector computed tomography (MDCT can be valuable to assess the severity of pulmonary embolism using the related cardiovascular parameters and leading the management strategy aim for best outcome. Keywords: Pulmonary embolism, MDCT, Cardiovascular, Computed tomography venography

  17. Characteristics of coronary artery disease in symptomatic type 2 diabetic patients: evaluation with CT angiography

    Directory of Open Access Journals (Sweden)

    Zhu Zhi-yu

    2010-11-01

    Full Text Available Abstract Background Coronary artery disease (CAD is a common and severe complication of type 2 diabetes mellitus (DM. The aim of this study is to identify the features of CAD in diabetic patients using coronary CT angiography (CTA. Methods From 1 July 2009 to 20 March 2010, 113 consecutive patients (70 men, 43 women; mean age, 68 ± 10 years with type 2 DM were found to have coronary plaques on coronary CTA. Their CTA data were reviewed, and extent, distribution and types of plaques and luminal narrowing were evaluated and compared between different sexes. Results In total, 287 coronary vessels (2.5 ± 1.1 per patient and 470 segments (4.2 ± 2.8 per patient were found to have plaques, respectively. Multi-vessel disease was more common than single vessel disease (p p p p p = 0.855. Extent of CAD, types of plaques and luminal narrowing were not significantly different between male and female diabetic patients. Conclusions Coronary CTA depicted a high plaque burden in patients with type 2 DM. Plaques, which were mainly calcified, were more frequently detected in the proximal segment of the LAD artery, and increased attention should be paid to the significant prevalence of obstructive stenosis. In addition, DM reduced the sex differential in CT findings of CAD.

  18. Anomalous vessel in the middle ear: the role of CT and MR angiography

    International Nuclear Information System (INIS)

    Caldas, J.G.M.P.; Iffenecker, C.; Lasjaunias, P.; Doyon, D.; Attal, P.

    1998-01-01

    An 8-year-old child was examined because of conductive hearing loss with a retrotympanic mass on otoscopy. CT and MR angiography showed a large inferior tympanic artery traversing the hypotympanum and joining a thin, irregular internal carotid artery with a normal middle meningeal artery. These investigations, coupled with knowledge of the embryological development allowed a diagnosis of a complex vascular anomaly in the middle ear and avoided potential surgical complications. (orig.)

  19. Assessment of the usefulness of three-dimensional CT angiography after peripheral arterial bypass surgery

    International Nuclear Information System (INIS)

    Hayashi, Saihou; Sasaki, Masaru; Kawamoto, Jun

    1997-01-01

    Conventional CT and three-dimensional CT angiography (3D-CTA) were conducted after peripheral arterial bypass surgery on 17 patients (26 grafts) from October, 1994 to April, 1996. Seventeen grafts were patent. The following objectives were satisfied in these cases: 1. Prosthetic graft or saphenous vein was depicted by 3D-CTA, 2. The distal portion of the native artery was depicted by 3D-CTA, and 3. Opacification of the graft interior was recognized by transverse section of CT. Nine grafts were occluded but prosthetic grafts were depicted in 5 cases, and prosthetic grafts and the distal portions of native arteries in 3 cases. Opacification of the graft interior was not seen in any case. Achievement of the above three objectives was considered necessary to determine graft patency. (author)

  20. Detection of coronary artery calcification by ultrafast CT and correlation with angiography

    International Nuclear Information System (INIS)

    Zhang Shaoxiong; Dai Ruping; Lu Bin

    1997-01-01

    To investigate the relationship between coronary calcification and significant coronary stenosis ninety patients including 81 men and 9 women were studied asithage ranging from 27∼72 years (mean, 58 years). All patients had both ultrafast CT (UFCT) examination and coronary angiography within one month. Single slice mode with ECG gating and thickness of 3 mm were used in UFCT scan. Selected coronary angiography was performed by the Judkins technique. Among 160 vessels in which coronary calcifications were identified, 74% had significant coronary stenosis (>50% stenosis), and 77% of 154 vessels with significant coronary stenosis had calcification demonstrable by UFCT. In the younger age group the sensitivity of calcification for evaluating stenosis of coronary artery was lower and the specificity was generally higher than those in the elderly group. UFCT is a promising procedure for detecting coronary arterial disease, since this examination has high sensitivity and specificity, easy to conduct, noninvasive, and widely applicable for screening a large population

  1. A Fast CT Reconstruction Scheme for a General Multi-Core PC

    Directory of Open Access Journals (Sweden)

    Kai Zeng

    2007-01-01

    Full Text Available Expensive computational cost is a severe limitation in CT reconstruction for clinical applications that need real-time feedback. A primary example is bolus-chasing computed tomography (CT angiography (BCA that we have been developing for the past several years. To accelerate the reconstruction process using the filtered backprojection (FBP method, specialized hardware or graphics cards can be used. However, specialized hardware is expensive and not flexible. The graphics processing unit (GPU in a current graphic card can only reconstruct images in a reduced precision and is not easy to program. In this paper, an acceleration scheme is proposed based on a multi-core PC. In the proposed scheme, several techniques are integrated, including utilization of geometric symmetry, optimization of data structures, single-instruction multiple-data (SIMD processing, multithreaded computation, and an Intel C++ compilier. Our scheme maintains the original precision and involves no data exchange between the GPU and CPU. The merits of our scheme are demonstrated in numerical experiments against the traditional implementation. Our scheme achieves a speedup of about 40, which can be further improved by several folds using the latest quad-core processors.

  2. A fast CT reconstruction scheme for a general multi-core PC.

    Science.gov (United States)

    Zeng, Kai; Bai, Erwei; Wang, Ge

    2007-01-01

    Expensive computational cost is a severe limitation in CT reconstruction for clinical applications that need real-time feedback. A primary example is bolus-chasing computed tomography (CT) angiography (BCA) that we have been developing for the past several years. To accelerate the reconstruction process using the filtered backprojection (FBP) method, specialized hardware or graphics cards can be used. However, specialized hardware is expensive and not flexible. The graphics processing unit (GPU) in a current graphic card can only reconstruct images in a reduced precision and is not easy to program. In this paper, an acceleration scheme is proposed based on a multi-core PC. In the proposed scheme, several techniques are integrated, including utilization of geometric symmetry, optimization of data structures, single-instruction multiple-data (SIMD) processing, multithreaded computation, and an Intel C++ compilier. Our scheme maintains the original precision and involves no data exchange between the GPU and CPU. The merits of our scheme are demonstrated in numerical experiments against the traditional implementation. Our scheme achieves a speedup of about 40, which can be further improved by several folds using the latest quad-core processors.

  3. Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Manghat, N.E.; Hamilton, M.C.K.; Joshi, D.; Lyen, S.M.; Negus, I.S.

    2014-01-01

    The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. (orig.)

  4. Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, J.C.L.; Manghat, N.E.; Hamilton, M.C.K. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); University Hospitals Bristol NHS Foundation Trust, National Institute for Health Research (NIHR) Cardiovascular Biomedical Research Unit, Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Joshi, D.; Lyen, S.M. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Negus, I.S. [University Hospitals Bristol NHS Foundation Trust, Department of Medical Physics and Bioengineering, Bristol Royal Infirmary, Bristol (United Kingdom)

    2014-10-15

    The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. (orig.)

  5. The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bo; Gu, Guo-jun; Jiang, Hong; Guo, Yi [Medical School of Tongji University, Department of Medical Imaging, Tongji Hospital, Shanghai (China); Shen, Xing [Traditional Chinese Hospital, Department of Radiology, Kun Shan, Jiangsu Province (China); Li, Bo; Zhang, Wei [Medical School of Jiaotong University, Department of Medical Imaging, Renji Hospital, Shanghai (China)

    2017-11-15

    To validate the value of whole-brain computed tomography perfusion (CTP) and CT angiography (CTA) in the diagnosis of mild cognitive impairment (MCI) and Alzheimer's disease (AD). Whole-brain CTP and four-dimensional CT angiography (4D-CTA) images were acquired in 30 MCI, 35 mild AD patients, 35 moderate AD patients, 30 severe AD patients and 50 normal controls (NC). Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and correlation between CTP and 4D-CTA were analysed. Elevated CBF in the left frontal and temporal cortex was found in MCI compared with the NC group. However, TTP was increased in the left hippocampus in mild AD patients compared with NC. In moderate and severe AD patients, hypoperfusion was found in multiple brain areas compared with NC. Finally, we found that the extent of arterial stenosis was negatively correlated with CBF in partial cerebral cortex and hippocampus, and positively correlated with TTP in these areas of AD and MCI patients. Our findings suggest that whole-brain CTP and 4D-CTA could serve as a diagnostic modality in distinguishing MCI and AD, and predicting conversion from MCI based on TTP of left hippocampus. (orig.)

  6. The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients

    International Nuclear Information System (INIS)

    Zhang, Bo; Gu, Guo-jun; Jiang, Hong; Guo, Yi; Shen, Xing; Li, Bo; Zhang, Wei

    2017-01-01

    To validate the value of whole-brain computed tomography perfusion (CTP) and CT angiography (CTA) in the diagnosis of mild cognitive impairment (MCI) and Alzheimer's disease (AD). Whole-brain CTP and four-dimensional CT angiography (4D-CTA) images were acquired in 30 MCI, 35 mild AD patients, 35 moderate AD patients, 30 severe AD patients and 50 normal controls (NC). Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and correlation between CTP and 4D-CTA were analysed. Elevated CBF in the left frontal and temporal cortex was found in MCI compared with the NC group. However, TTP was increased in the left hippocampus in mild AD patients compared with NC. In moderate and severe AD patients, hypoperfusion was found in multiple brain areas compared with NC. Finally, we found that the extent of arterial stenosis was negatively correlated with CBF in partial cerebral cortex and hippocampus, and positively correlated with TTP in these areas of AD and MCI patients. Our findings suggest that whole-brain CTP and 4D-CTA could serve as a diagnostic modality in distinguishing MCI and AD, and predicting conversion from MCI based on TTP of left hippocampus. (orig.)

  7. Cardiac pathologies incidentally detected with non-gated chest CT; Inzidentelle Pathologien des Herzens im Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Axel; Kroepil, P.; Lanzman, R.S.; Moedder, U. [Inst. fuer Radiologie, Universitaetsklinikum Duesseldorf, Heinrich-Heine-Univ. (Germany); Choy, G.; Abbara, S. [Cardiovascular Imaging Section, Massachusetts General Hospital, Harvard Medical School (United States)

    2009-12-15

    Cardiac imaging using electrocardiogram-gated multi-detector computed tomography (MDCT) permits noninvasive diagnosis of congenital and acquired cardiac pathologies and has thus become increasingly important in the last years. Several studies investigated the incidence and relevance of incidental extracardiac structures within the lungs, mediastinum, chest wall, and abdomen with gated coronary CT. This resulted in the general acceptance of the review of extracardiac structures as a routine component of coronary CT interpretation. On the other hand radiologists tend to neglect pericardial and cardiac pathologies in non-gated chest CT, which is primarily performed for the evaluation of the respiratory system or for tumor staging. Since the introduction of multi-detector spiral CT technology, the incidental detection of cardiac and pericardial findings has become possible using non-gated chest CT. This article reviews the imaging appearances and differential diagnostic considerations of incidental cardiac entities that may be encountered in non-gated chest CT. (orig.)

  8. Three-dimensional anatomical evaluation of bronchial artery with CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Tao Xiaofeng

    2006-01-01

    Objective: To evaluate the ability of CT angiography in identifying and demonstrating the origins and courses of bronchial arteries by using the three-dimensional reformation technique. Methods Four hundred and forty-three eases were examined with thin-section enhanced MSCT. Three-dimensional images of bronchial arteries were processed at the workstation. Spatial anatomical characters of the bronchial arteries using volume rendering(VR), muhiplanar reconstruction (MPR), and maxium intensity projection (MIP) were observed. Results: At least one bronchial artery was clearly displayed in VR in 359 eases. The right bronchial arteries mainly appeared to originate from the right intercostal artery (213/436, 48.85% ) and descending aorta (207/436, 47.48%), while the left bronchial arteries mainly from the descending aorta (363/371, 97.84%). The right bronchial arteries of the descending aorta were mainly arised from fight wall (95/207, 45.89%), and then the anterior wall (88/207, 42.51%), while the left bronchial arteries of the descending aorta mainly arised from anterior wall of the aorta (272/363, 74.93%). The common trunk originated from the descending aorta mainly positioned in the anterior wall (57/77, 74.03%). 49.31% (215/436) of the fight bronchial arteries were coursing across the posterior edge of the right main bronchi, 35.55% (155/436) coursing the inferior edge, while 60.11% (223/371) of left bronchial arteries coursing forward across the superior edger of the left main bronchi, the others coursing the inferior or the posterior edge. There were eleven bronchial artery distribution patterns, with the right and left ones predominating (192/359, 53.48%), and then two right and one left (63/359, 17.55%). Conclusion: The bronchial artery anatomy was complicated, and CT angiography could clearly visualize the features. (authors)

  9. CT angiography and CT perfusion improve prediction of infarct volume in patients with anterior circulation stroke

    Energy Technology Data Exchange (ETDEWEB)

    Seeters, Tom van; Schaaf, Irene C. van der; Dankbaar, Jan Willem; Horsch, Alexander D.; Niesten, Joris M.; Luitse, Merel J.A.; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, Geert Jan; Kappelle, L.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Vos, Jan Albert [St. Antonius Hospital, Department of Radiology, Nieuwegein (Netherlands); Schonewille, Wouter J. [St. Antonius Hospital, Department of Neurology, Nieuwegein (Netherlands); Walderveen, Marianne A.A. van [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Wermer, Marieke J.H. [Leiden University Medical Center, Department of Neurology, Leiden (Netherlands); Duijm, Lucien E.M. [Catharina Hospital, Department of Radiology, Eindhoven (Netherlands); Keizer, Koos [Catharina Hospital, Department of Neurology, Eindhoven (Netherlands); Bot, Joseph C.J. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Visser, Marieke C. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Lugt, Aad van der [Erasmus MC University Medical Center, Department of Radiology, Rotterdam (Netherlands); Dippel, Diederik W.J. [Erasmus MC University Medical Center, Department of Neurology, Rotterdam (Netherlands); Kesselring, F.O.H.W. [Rijnstate Hospital, Department of Radiology, Arnhem (Netherlands); Hofmeijer, Jeannette [Rijnstate Hospital, Department of Neurology, Arnhem (Netherlands); Lycklama a Nijeholt, Geert J. [Medical Center Haaglanden, Department of Radiology, The Hague (Netherlands); Boiten, Jelis [Medical Center Haaglanden, Department of Neurology, The Hague (Netherlands); Rooij, Willem Jan van [St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Kort, Paul L.M. de [St. Elisabeth Hospital, Department of Neurology, Tilburg (Netherlands); Roos, Yvo B.W.E.M. [Academic Medical Center, Department of Neurology, Amsterdam (Netherlands); Meijer, Frederick J.A. [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Pleiter, C.C. [St. Franciscus Hospital, Department of Radiology, Rotterdam (Netherlands); Graaf, Yolanda van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Collaboration: Dutch acute stroke study (DUST) investigators

    2016-04-15

    We investigated whether baseline CT angiography (CTA) and CT perfusion (CTP) in acute ischemic stroke could improve prediction of infarct presence and infarct volume on follow-up imaging. We analyzed 906 patients with suspected anterior circulation stroke from the prospective multicenter Dutch acute stroke study (DUST). All patients underwent baseline non-contrast CT, CTA, and CTP and follow-up non-contrast CT/MRI after 3 days. Multivariable regression models were developed including patient characteristics and non-contrast CT, and subsequently, CTA and CTP measures were added. The increase in area under the curve (AUC) and R{sup 2} was assessed to determine the additional value of CTA and CTP. At follow-up, 612 patients (67.5 %) had a detectable infarct on CT/MRI; median infarct volume was 14.8 mL (interquartile range (IQR) 2.8-69.6). Regarding infarct presence, the AUC of 0.82 (95 % confidence interval (CI) 0.79-0.85) for patient characteristics and non-contrast CT was improved with addition of CTA measures (AUC 0.85 (95 % CI 0.82-0.87); p < 0.001) and was even higher after addition of CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001) and combined CTA/CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001). For infarct volume, adding combined CTA/CTP measures (R{sup 2} = 0.58) was superior to patient characteristics and non-contrast CT alone (R{sup 2} = 0.44) and to addition of CTA alone (R{sup 2} = 0.55) or CTP alone (R{sup 2} = 0.54; all p < 0.001). In the acute stage, CTA and CTP have additional value over patient characteristics and non-contrast CT for predicting infarct presence and infarct volume on follow-up imaging. These findings could be applied for patient selection in future trials on ischemic stroke treatment. (orig.)

  10. Ectopic origin of bronchial arteries: assessment with multidetector helical CT angiography

    International Nuclear Information System (INIS)

    Hartmann, Ieneke J.C.; Remy-Jardin, Martine; Menchini, Laura; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques

    2007-01-01

    The purpose of this study was to determine non-invasively the frequency of ectopic bronchial arteries (BA) (i.e., bronchial arteries originating at a level of the descending aorta other than T5-T6 or from any aortic collateral vessel) on multidetector-row CT angiograms (CTA) obtained in patients with hemoptysis. Over a 5-year period (2000-2005), 251 consecutive patients with hemoptysis underwent multidetector-row CT angiography of the thorax. From this population, 37 patients were excluded because of a suboptimal CTA examination (n = 19), the presence of extensive mediastinal disease (n = 15) or severe chest deformation (n = 3) precluding any precise analysis of the bronchial arteries at CTA. Our final study group included 214 patients who underwent a thin-collimated CT angiogram (contrast agent: 300 to 350 mg/ml) on a 4- (n = 56), 16- (n = 119) and 64- (n = 39) detector-row scanner. The site of origin and distribution of bronchial arteries were analyzed on transverse CT scans, maximum intensity projections and volume-rendered images. The site of the ostium of a bronchial artery was coded as orthotopic when the artery originated from the descending aorta between the levels of the fifth and sixth thoracic vertebrae; all other bronchial arteries were considered ectopic. From the studied population, 137 (64%) patients had only orthotopic bronchial arteries, whereas 77 patients (36%) had at least one bronchial artery of ectopic origin. A total of 147 ectopic arteries were depicted, originating as common bronchial trunks (n = 23; 19%) or isolated right or left bronchial arteries (n = 101; 81%). The most frequent sites of origin of the 124 ostiums were the concavity of the aortic arch (92/124; 74%), the subclavian artery (13/124; 10.5%) and the descending aorta (10/124; 8.5%). The isolated ectopic bronchial arteries supplied the ipsilateral lung in all but three cases. Bronchial artery embolization was indicated in 26 patients. On the basis of CTA information, (1

  11. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  12. [Giant aneurysm of posterior comunicating artery (PCoA) in cerebral panarteriography and CT angiography (CTA)].

    Science.gov (United States)

    Jaźwiec, Przemysław; Chwiszczuk, Luiza; Sasiadek, Marek; Całka, Karol; Kuniej, Tomasz; Plucińska, Irena

    2008-01-01

    We present a case of 32-year-old woman, who was admitted to the Department of Neurology in the emergency mode, due to: instantaneous pupillary dilation (mydriasis), ptosis of the left eyeball and double vision. We performed plain CT, panarteriography of cerebral vessels, CT angiography with RT3D (volume-rendered three-dimensional) reconstruction images. On the base of imaging studies the diagnosis of giant saccular aneurysm of the left posterior communicating artery was established. The patient was operated on and the giant aneurysm of left posterior communicating artery was clipped, confirming radiological diagnosis. During operation and postoperative period no complications were noted.

  13. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    Directory of Open Access Journals (Sweden)

    Moritz Kaup

    2016-12-01

    Full Text Available Background Computed tomography (CT low-dose (LD imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA. Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR and signal-to-noise ratios (SNR were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy. Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768. Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4. Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

  14. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    Science.gov (United States)

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  15. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    International Nuclear Information System (INIS)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  16. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Gyeonggi-do (Korea, Republic of); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Gyeonggi-do (Korea, Republic of)

    2011-04-15

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  17. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    Science.gov (United States)

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siablis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece)]. E-mail: siablis@med.upatras.gr; Kagadis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karamessini, Maria T. [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Konstantinou, Dimitrios [Department of Neurosurgery, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Petsas, Theodore [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Nikiforidis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece)

    2005-07-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.

  19. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Kagadis, George C.; Karamessini, Maria T.; Konstantinou, Dimitrios; Karnabatidis, Dimitrios; Petsas, Theodore; Nikiforidis, George C.

    2005-01-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms

  20. Interobserver variability in the evaluation of internal carotid artery stenosis by CT angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Meli, Francisco; Sampere, Tulio; Capunay, Carlos; Sanchez, Flavio; Carrascosa, Jorge

    2001-01-01

    Ischemic cerebral vascular events are primarily due to atherosclerotic narrowing of carotid bifurcation. Catheter Angiography (CA) is the best test for determining carotid artery stenosis, but it is invasive and has some risks. The purpose of this study was to evaluate CT Angiography (CTA) as a non-invasive method compared with CA. Different estimate procedures (NASCET, ESCT and area quantification) were done to compare the Sensitivity (S) and Specificity (E) of each one with CA. Afterwards, interobserver variability of the three procedures was evaluated. Thirty-eight internal carotid arteries were studied in 19 patients with transient ischemic attacks. CTA studies were done in a helical CT scanner. The images were evaluated in a workstation by two radiologists, who were blinded to the percentage of stenosis determined by CA. For statistical analysis, the measurement of stenosis percentage was divided in two groups: a) Negative (0-69%) and b) Positive:(70-100%). Kappa analysis (K) was used to determine the agreement of stenosis. Results: Observer 1: Sensitivity (S) NASCET: 94%, ESCT: 77% and area 94% and Specificity (E): 91%, 87,5% and 87,5%. Observer 2: 77%, 77% and 74%. The interobserver K was 0.83, 0792 and 0.78 for NASCET, ESCT and area quantification methods respectively. In conclusion, CTA has high S and E especially in NASCET and area quantification. (author)

  1. Image quality on dual-source computed-tomographic coronary angiography

    International Nuclear Information System (INIS)

    Rixe, Johannes; Rolf, Andreas; Conradi, Guido; Elsaesser, Albrecht; Moellmann, Helge; Nef, Holger M.; Hamm, Christian W.; Dill, Thorsten; Bachmann, Georg

    2008-01-01

    Multi-detector CT reliably permits visualization of coronary arteries, but due to the occurrence of motion artefacts at heart rates >65 bpm caused by a temporal resolution of 165 ms, its utilisation has so far been limited to patients with a preferably low heart rate. We investigated the assessment of image quality on computed tomography of coronary arteries in a large series of patients without additional heart rate control using dual-source computed tomography (DSCT). DSCT (Siemens Somatom Definition, 83-ms temporal resolution) was performed in 165 consecutive patients (mean age 64±11.4 years) after injection of 60-80 ml of contrast. Data sets were reconstructed in 5% intervals of the cardiac cycle and evaluated by two readers in consensus concerning evaluability of the coronary arteries and presence of motion and beam-hardening artefacts using the AHA 16-segment coronary model. Mean heart rate during CT was 65±10.5 bpm; visualisation without artefacts was possible in 98.7% of 2,541 coronary segments. Only two segments were considered unevaluable due to cardiac motion; 30 segments were unassessable due to poor signal-to-noise ratio or coronary calcifications (both n=15). Data reconstruction at 65-70% of the cardiac cycle provided for the best image quality. For heart rates >85 bpm, a systolic reconstruction at 45% revealed satisfactory results. Compared with earlier CT generations, DSCT provides for non-invasive coronary angiography with diagnostic image quality even at heart rates >65 bpm and thus may broaden the spectrum of patients that can be investigated non-invasively. (orig.)

  2. Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement

    International Nuclear Information System (INIS)

    Ruiz, Yolanda; Caballero, Paloma; Caniego, Jose Luis; Friera, Alfonsa; Olivera, Maria Jose; Tagarro, David; Alvarez-Sala, Rodolfo

    2003-01-01

    The objective of this prospective study was to evaluate the sensitivity, specificity, positive and negative predictive values, and interobserver agreement in the diagnosis of pulmonary embolism with helical CT, compared with pulmonary angiography, for both global results and for selective vascular territories. Helical CT and pulmonary angiography were performed on 66 consecutive patients with clinical suspicion of pulmonary embolism. The exams were blindly interpreted by a vascular radiologist and by two independent thoracic radiologists. Results were analyzed for the final diagnosis as well as separately for 20 different arterial territories in each patient. Pulmonary angiography revealed embolism in 25 patients (38%); 48% were main, 28% lobar, 16% segmental, and 8% subsegmental. The sensitivity, specificity, and positive and negative predictive values of helical CT for observer 1 were, respectively, 91, 81.5, 75, and 94%; in 7.5% of the patients the exam was considered indeterminate. For observer 2 the values were, respectively, 88, 86, 81.5, and 91%; in 9% of the patients the exam was considered indeterminate. Main arteries were considered as non-valuable in 0-0.8%, the lobar in 1.5%, the segmental in 7.5-8.5%, and the subsegmental in 55-60%. Interobserver agreement for the final diagnosis was 80% (kappa 0.65). For each vascular territory, this was 98% (kappa 0.91) for main arteries, 92% (kappa 0.78) for lobar arteries, 79% (kappa 0.56) for segmental arteries, and 59% (kappa 0.21) for subsegmental arteries. Helical CT is a reliable method for pulmonary embolism diagnosis, with good interobserver agreement for main, lobar, and segmental territories. Worse results are found for subsegmental arteries, with high incidence of non-valuable branches and poor interobserver agreement. (orig.)

  3. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    International Nuclear Information System (INIS)

    Fischer, Lars; Tetzlaff, Ralf; Schoebinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H.P.; Buechler, M.W.; Schemmer, Peter

    2010-01-01

    Introduction: The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. Material and Methods: All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Results: Segmentation of the liver was performed in significantly shorter time (p < 0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p = 0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p = 0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p = 0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these

  4. Thoracic Injuries in earthquake-related versus non-earthquake-related trauma patients: differentiation via Multi-detector Computed Tomography

    Science.gov (United States)

    Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng

    2011-01-01

    PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; pchest (45/143 vs. 11/66 patients, RR = 1.9; ptraumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386

  5. Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: Observations in an ex vivo model

    NARCIS (Netherlands)

    L. la Grutta (Ludovico); M. Galia (Massimo); G. Gentile; G. Lo Re (G.); E. Grassedonio (Emanuele); F. Coppolino; E. Maffei (Erica); E. Maresi (E.); A. Lo Casto (A.); F. Cademartiri (Filippo); M. Midiri (Massimo)

    2013-01-01

    textabstractObjective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT

  6. Multi-detector row CT in the assessment of axillary lymph node metastasis in breast cancer

    International Nuclear Information System (INIS)

    Murakami, Shogo

    2003-01-01

    The purpose of this study is to evaluate the diagnostic capability instead of clinical efficacy of multi-detector row CT (MDCT) in the assessment of axillary lymph node metastasis in breast cancer. MDCT was performed in 63 patients with breast cancer, and multiplanar reformation (MPR) and volume rendering (VR) images were reconstructed for the evaluation of bilateral axillary lymph nodes. Two hundred sixty eight lymph nodes were depicted with MDCT, and correlation with pathological findings was performed. The short axis length of lymph node was measured on MPR image, and the shape of the nodes was analyzed with the pathological results statistically. The diagnostic criteria on size and shape of lymph node metastasis were discussed Dynamic study with contrast media was also performed, and the CT value ratios (CTVR) of the lymph nodes and breast tumors were calculated. No relevance of axillary lymph node metastasis was noted to the pathological types of breast cancer. The average short axis length of the ipsilateral axillary nodes was 8.9 mm±3.8 (SD) while that of the contralateral nodes was 4.9 mm±1.1 (SD) showing significant difference. More than 6.5 mm in short length of the lymph node was thought to be an effective criterion for positive metastasis, and its sensitivity was 96%. Soybean-shape lymph node was statistically common in metastasis, while non-metastatic nodes were commonly demonstrated as letter ''c'' shape or ring-like shape. Statistical relevance was obtained between the CTVR of axillary lymph nodes and that of breast tumors, suggesting clinical usefulness of dynamic study using contrast media in the evaluation of lymph node metastasis. With MPR and VR images using MDCT, more accurate morphological evaluation of axillary lymph nodes was possible. When soybean-shape node with more than 6.5 mm in short axis is depicted in the axillar region on MDCT metastasis should be the consideration. Comparison with the contralateral side as a control in coronal

  7. Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update

    Directory of Open Access Journals (Sweden)

    Nakanishi R

    2016-06-01

    Full Text Available Rine Nakanishi, Mathew J Budoff Los Angeles Biomedical Research Institute, Harbor-UCLA Medical Center, Torrance, CA, USA Abstract: After a decade of clinical use of coronary computed tomographic angiography (CCTA to evaluate the anatomic severity of coronary artery disease, new methods of deriving functional information from CCTA have been developed. These methods utilize the anatomic information provided by CCTA in conjunction with computational fluid dynamics to calculate fractional flow reserve (FFR values from CCTA image data sets. Computed tomography-derived FFR (CT-FFR enables the identification of lesion-specific drop noninvasively. A three-dimensional CT-FFR modeling technique, which provides FFR values throughout the coronary tree (HeartFlow FFRCT analysis, has been validated against measured FFR and is now approved by the US Food and Drug Administration for clinical use. This technique requires off-site supercomputer analysis. More recently, a one-dimensional computational analysis technique (Siemens cFFR, which can be performed on on-site workstations, has been developed and is currently under investigation. This article reviews CT-FFR technology and clinical evidence for its use in stable patients with suspected coronary artery disease. Keywords: fractional flow reserve, coronary computed tomographic angiography, FFRCT, cFFR

  8. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  9. Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Koung Mi; Choi, Sang Il; Chun, Eun Ju; Kim, Jeong A; Youn, Tae Jin; Choi, Dong Ju [Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2012-01-15

    We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.

  10. Mediastinal and hilar lymphadenopathy: cross-referenced anatomy on axial and coronal images displayed by using multi-detector row CT

    International Nuclear Information System (INIS)

    Lee, Ju Hyun; Lee, Kyung Soo; Kim, Tae Sung; Yi, Chin A; Cho, Jae Min; Lee, Min Hee

    2003-01-01

    The accurate evaluation of mediastinal and pulmonary hilar lymphadenopathy, especially in patients with lung cancer, is important for determining treatment options and evaluating the response to therapy. To indicate nodal location in detail, mediastinal and hilar lymph nodes have been assigned to one of 14 nodal stations. Mediastinal nodes of greater than 10 mm short-axis diameter are regarded as abnormal, irrespective of their nodal station, while hilar nodes are considered abnormal if their diameter is greater than 10 mm in any axis or they are convex compared to surrounding lung. By providing multiplanar images, multi-detector row CT allows detailed evaluation of thoracic anatomic structures more easily than in the past, when axial images only were available. At cross-referenced imaging, a lymph node depicted at axial imaging in one anatomical location can be visualized simultaneously and automatically at coronal imaging at the exactly corresponding anatomical location. Cross-referenced coincidental axial and coronal images help assess both the size and morphology of mediastinal and hilar lymph nodes

  11. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  12. Respiratory gated lung CT using 320-row area detector CT

    International Nuclear Information System (INIS)

    Sakamoto, Ryo; Noma, Satoshi; Higashino, Takanori

    2010-01-01

    Three hundred and twenty-row Area Detector CT (ADCT) has made it possible to scan whole lung field with prospective respiratory gated wide volume scan. We evaluated whether the respiratory gated wide volume scan enables to reduce motion induced artifacts in the lung area. Helical scan and respiratory gated wide volume scan were performed in 5 patients and 10 healthy volunteers under spontaneous breathing. Significant reduction of motion artifact and superior image quality were obtained in respiratory gated scan in comparison with helical scan. Respiratory gated wide volume scan is an unique method using ADCT, and is able to reduce motion artifacts in lung CT scans of patients unable to suspend respiration in clinical scenes. (author)

  13. A multi-channel photometric detector for multi-component analysis in flow injection analysis.

    Science.gov (United States)

    Tan, A; Huang, J; Geng, L; Xu, J; Zhao, X

    1994-01-01

    The detector, a multi-channel photometric detector, described in this paper was developed using multi-wavelength LEDs (light emitting diode) and phototransistors for absorbance measurement controlled by an Intel 8031 8-bit single chip microcomputer. Up to four flow cells can be attached to the detector. The LEDs and phototransistors are both inexpensive, and reliable. The results given by the detector for simultaneous determination of trace amounts of cobalt and cadmium in zinc sulphate electrolyte are reported. Because of the newly developed detector, this approach employs much less hardware apparatus than by employing conventional photometric detectors.

  14. Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography.

    Science.gov (United States)

    Schwarz, Florian; Nance, John W; Ruzsics, Balazs; Bastarrika, Gorka; Sterzik, Alexander; Schoepf, U Joseph

    2012-09-01

    To evaluate the feasibility of using virtual noncontrast material-enhanced (VNC) computed tomographic (CT) series derived from dual-energy CT imaging studies for coronary artery calcium quantification. This HIPAA-compliant study was institutional review board approved; all patients provided written informed consent. Thirty-six patients prospectively underwent noncontrast-enhanced CT calcium scoring followed by coronary CT angiography performed in dual-energy mode. By using different reconstruction algorithms, three VNC series were generated and evaluated for noise and efficiency of virtual iodine removal. Two readers independently quantified calcium on VNC images and true noncontrast-enhanced conventional calcium scoring series. A leave-one-out cross validation was used to assess the accuracy of calcium score prediction from VNC series by means of linear regression. CT value histograms of the VNC series closely resembled the profile in the true noncontrast-enhanced series. There was excellent correlation between calcium volumes on the VNC series and true noncontrast-enhanced series on a per-patient (r = 0.94, P VNC series was excellent (r = 0.82). Multiethnic Study of Atherosclerosis rankings that were derived from the predicted calcium scores also showed excellent agreement (intraclass correlation coefficient = 0.909). Coronary artery calcium identification and quantification based on dual-energy coronary CT angiographic studies may obviate the need for dedicated CT calcium scoring studies. © RSNA, 2012

  15. First experience with multidetector-CT for the diagnosis of coronary atherosclerosis

    International Nuclear Information System (INIS)

    Becker, C.R.; Hong, C.; Schoepf, U.J.; Reiser, M.F.; Knez, A.; Leber, A.; Treede, H.; Wildhirt, S.; Ohnesorge, B.; Flohr, T.

    2000-01-01

    Purpose: Multirow-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries. Methods: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate. Results: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59±8 beats per minute. Conclusion: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries. (orig.) [de

  16. Double Chooz Improved Multi-Detector Measurements

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero θ13 with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of θ13 followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC’s unique almost "iso-flux" site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of θ13 with respect to the world average. We will address this issue in this seminar. The combined "reactor-θ13" measurement is expected to ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  18. Atherosclerotic Plaque Characteristics by CT Angiography Identify Coronary Lesions That Cause Ischemia: a Direct Comparison to Fractional Flow Reserve

    Science.gov (United States)

    Park, Hyung-Bok; Heo, Ran; Hartaigh, Bríain ó; Cho, Iksung; Gransar, Heidi; Nakazato, Ryo; Leipsic, Jonathon; Mancini, G.B. John; Koo, Bon-Kwon; Otake, Hiromasa; Budoff, Matthew J.; Berman, Daniel S.; Erglis, Andrejs; Chang, Hyuk-Jae; Min, James K.

    2014-01-01

    Objective We evaluated the association between atherosclerotic plaque characteristics (APCs) by coronary CT angiography (CT) and lesion ischemia by fractional flow reserve (FFR). Background FFR is the gold standard for determining lesion ischemia. While APCs by CT—including aggregate plaque volume % (%APV), positive remodeling (PR), low attenuation plaque (LAP) and spotty calcification (SC)—are associated with future coronary syndromes, their relationship to lesion ischemia is unclear. Methods 252 patients (17 centers, 5 countries) [mean age 63 years, 71% males] underwent CT, with FFR performed for 407 coronary lesions. CT was interpreted for 50% stenosis, with the latter considered obstructive. APCs by CT were defined as: (1) PR, lesion diameter/reference diameter >1.10; (2) LAP, any voxel 50% but not for 50%. PMID:25592691

  19. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  20. Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

    International Nuclear Information System (INIS)

    Shen, Junlin; Du, Xiangying; Guo, Daode; Cao, Lizhen; Gao, Yan; Bai, Mei; Li, Pengyu; Liu, Jiabin; Li, Kuncheng

    2013-01-01

    Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17–35.08 HU) and Group 3 (34.34–35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose

  1. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  2. Multi-energy spectral CT: adding value in emergency body imaging.

    Science.gov (United States)

    Punjabi, Gopal V

    2018-04-01

    Most vendors offer scanners capable of dual- or multi-energy computed tomography (CT) imaging. Advantages of multi-energy CT scanning include superior tissue characterization, detection of subtle iodine uptake differences, and opportunities to reduce contrast dose. However, utilization of this technology in the emergency department (ED) remains low. The purpose of this pictorial essay is to illustrate the value of multi-energy CT scanning in emergency body imaging.

  3. Efficacy of dynamic CT perfusion imaging in conjunction with three dimensional CT angiography for the evaluation of acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Teraoka, Akira; Adachi, Shinobu; Yanagibashi, Kazutaka [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan)

    2003-01-01

    Through the use of a high-speed spiral CT scanner (GEMedical HiSpeedZX/i), CT/P/A technique, where conventional CT, CT perfusion imaging (CTP) and CT angiography (CTA) are consecutively performed, can now be performed with an imaging time of 90 seconds and a total contrast medium volume of 100 ml. A prospective clinical study was performed to ascertain the effectiveness of CT/P/A in diagnosing acute ischemic strokes. Twenty-nine consecutive patients of Teraoka Memorial Hospital suspected of suffering from the occlusion or constriction of cerebral arteries and who underwent CT/P/A within 3 hours from the onset served as subjects. The sensitivity, specificity, or Odds ratio of CTP and CTA in detecting lesions that caused cerebral infarction was calculated. CTP detected a hypoperfusion area with a sensitivity, specificity, and Odds ratio of 80%, 64%, and 7.2. The sensitivity in lobar infarcts, white matter infarcts, basal ganglia infarcts, and brainstem infarcts was 100%, 100%, 100%, 0% (p=0.0022). The sensitivity and Odds ratio of CT/P/A in cerebral infarcts differed according to the diameter of the infarcts. That with infarcts of 10 mm or more was 91%, 20. That with infarcts smaller than 10 mm was 50%, 2. CTA detected arterial lesions that caused cerebral ischemic attack with a sensitivity of 94% and specificity of 90%. The examination time for CT/P/A was 18 minutes, total radiation time being 90 seconds. Although CT/P/A was ineffective for the diagnosis of brainstem infarcts and lesions smaller than 10 mm, CT/P/A was useful in detecting moderate-sized hypoperfusion areas and arterial lesions three-dimensionally before an infarct is completed. (author)

  4. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  5. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  6. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose

  7. Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography

    International Nuclear Information System (INIS)

    Meier, A.; Wurnig, M.; Desbiolles, L.; Leschka, S.; Frauenfelder, T.; Alkadhi, H.

    2015-01-01

    Aim: To investigate the value of advanced virtual monoenergetic image reconstruction (mono-plus) from dual-energy computed tomography (CT) for improving the contrast of CT pulmonary angiography (CTPA). Materials and methods: Forty consecutive patients (25 women, mean 62.5 years, range 28–87 years) underwent 192-section dual-source CTPA with dual-energy CT (90/150 SnkVp) after the administration of 60 ml contrast media (300 mg iodine/ml). Conventional virtual monochromatic images at 60 keV and 17 mono-plus image datasets from 40–190 keV (in 10 keV steps) were reconstructed. Subjective image quality (artefacts, subjective noise) was rated. Attenuation was measured in the pulmonary trunk and in the right lower lobe pulmonary artery; noise was measured in the periscapular musculature. The signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for each patient and dataset. Comparisons between monochromatic images and mono-plus images were performed by repeated measures analysis of variance (ANOVA) with post-hoc Bonferroni correction. Results: Interreader agreement was good to excellent for subjective image quality (ICC: 0.616–0.889). As compared to conventional 60 keV images, artefacts occurred less (p=0.001) and subjective noise was rated lower (p<0.001) in mono-plus 40 keV images. Noise was lower (p<0.001), and the SNR and CNR in the pulmonary trunk and right lower lobe pulmonary artery were higher (both, p<0.001) in mono-plus 40 keV images compared to conventional monoenergetic 60 keV images. Transient interruption of contrast (TIC) was found in 14/40 (35%) of patients, with subjective contrast being similar 8/40 (20%) or higher 32/40 (80%) in mono-plus 40 keV as compared to conventional monoenergetic 60 keV images. Conclusions: Compared to conventional virtual monoenergetic imaging, mono-plus images at 40 keV improve the contrast of dual-energy CTPA. - Highlights: • Advanced monoenergetic image reconstruction from dual-energy CT

  8. New developments in PET detector technology

    International Nuclear Information System (INIS)

    Niu Lingxin; Zhao Shujun; Zhang Bin; Liu Haojia

    2010-01-01

    The researches on PET detector are always active and innovative area. The research direction of PET detector includes improving performances of scintillator-based detectors, investigating new detectors suitable for multi-modality imaging (e.g. PET/CT and PET/MRI), meeting requirements of TOF and DOI technologies and boosting the development of the technologies. In this paper, new developments in PET detector technology about scintillation crystal, photodetector and semiconductor detector is introduced. (authors)

  9. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have ...

  10. Topography of the accessory left gastric artery (ALGA) analyzed by CT angiography from the left hepatic artery

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Takasaka, Isao; Onaya, Hiroaki

    2003-01-01

    To avoid gastric complications when we perform transcatheter treatment via left hepatic artery, we analyzed the topography of ALGA (accessory left gastric artery) by left hepatic arteriography and CT angiography from left hepatic artery. Six hundred seventy eight cases of CT angiography were performed between 1995 and 2000. Among them, selective left hepatic arteriography was done in 85 cases. We analyzed the frequency and the course of ALGA on the hepatic angiogram and CT angiogram. ALGA were identified in eighteen (21.2 %) of the 85 cases. We classified them into eleven cases of the proximal type and six cases of the distal type. When ALGA bifurcated from the left hepatic artery very close to the bifurcation of A2 (dorsolateral branch) and A3 (ventrolateral branch), we classified them as the distal type on hepatic angiogram. On the other hand, when ALGA bifurcated from the left hepatic artery apart from the bifurcation of A2 and A3 they were classified as the proximal type. In one rare case ALGA originated from the dorsolateral branch of the left hepatic artery. ALGA were classified as the distal and proximal types. Distal type of ALGA often overlapped dorsolateral branch of the left hepatic artery, and it was sometimes difficult to notice the existence of them. We should check the existence of ALGA on the arterial phase of dynamic CT before we plan to make a transcatheter treatment from the left hepatic artery. Then we can avoid gastric complications caused by a transcatheter treatment from the left hepatic artery. (author)

  11. Phantom-based standardization of CT angiography images for spot sign detection

    International Nuclear Information System (INIS)

    Morotti, Andrea; Rosand, Jonathan; Romero, Javier M.; Jessel, Michael J.; Vashkevich, Anastasia; Schwab, Kristin; Greenberg, Steven M.; Hernandez, Andrew M.; Boone, John M.; Burns, Joseph D.; Shah, Qaisar A.; Bergman, Thomas A.; Suri, M.F.K.; Ezzeddine, Mustapha; Kirmani, Jawad F.; Agarwal, Sachin; Hays Shapshak, Angela; Messe, Steven R.; Venkatasubramanian, Chitra; Palmieri, Katherine; Lewandowski, Christopher; Chang, Tiffany R.; Chang, Ira; Rose, David Z.; Smith, Wade; Hsu, Chung Y.; Liu, Chun-Lin; Lien, Li-Ming; Hsiao, Chen-Yu; Iwama, Toru; Afzal, Mohammad Rauf; Qureshi, Adnan I.; Cassarly, Christy; Hebert Martin, Renee; Goldstein, Joshua N.

    2017-01-01

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p < 0.001). All spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion. (orig.)

  12. Phantom-based standardization of CT angiography images for spot sign detection.

    Science.gov (United States)

    Morotti, Andrea; Romero, Javier M; Jessel, Michael J; Hernandez, Andrew M; Vashkevich, Anastasia; Schwab, Kristin; Burns, Joseph D; Shah, Qaisar A; Bergman, Thomas A; Suri, M Fareed K; Ezzeddine, Mustapha; Kirmani, Jawad F; Agarwal, Sachin; Shapshak, Angela Hays; Messe, Steven R; Venkatasubramanian, Chitra; Palmieri, Katherine; Lewandowski, Christopher; Chang, Tiffany R; Chang, Ira; Rose, David Z; Smith, Wade; Hsu, Chung Y; Liu, Chun-Lin; Lien, Li-Ming; Hsiao, Chen-Yu; Iwama, Toru; Afzal, Mohammad Rauf; Cassarly, Christy; Greenberg, Steven M; Martin, Renee' Hebert; Qureshi, Adnan I; Rosand, Jonathan; Boone, John M; Goldstein, Joshua N

    2017-09-01

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion.

  13. Phantom-based standardization of CT angiography images for spot sign detection

    Energy Technology Data Exchange (ETDEWEB)

    Morotti, Andrea; Rosand, Jonathan [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Romero, Javier M. [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Neuroradiology Service, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jessel, Michael J.; Vashkevich, Anastasia; Schwab, Kristin; Greenberg, Steven M. [Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Hernandez, Andrew M.; Boone, John M. [University of California Davis, Department of Radiology, Sacramento, CA (United States); Burns, Joseph D. [Lahey Hospital and Medical Center, Department of Neurology, Burlington, MA (United States); Shah, Qaisar A. [Abington Memorial Hospital, Abington, PA (United States); Bergman, Thomas A. [Hennepin County Medical Center, Minneapolis, MN (United States); Suri, M.F.K. [St. Cloud Hospital, St. Cloud, MN (United States); Ezzeddine, Mustapha [University of Minnesota, Minneapolis, MN (United States); Kirmani, Jawad F. [JFK Medical Center, Stroke and Neurovascular Center, Edison, NJ (United States); Agarwal, Sachin [Columbia University Medical Center, New York, NY (United States); Hays Shapshak, Angela [University of Alabama at Birmingham, Birmingham, AL (United States); Messe, Steven R. [University of Pennsylvania, Philadelphia, PA (United States); Venkatasubramanian, Chitra [Stanford University, Stanford, CA (United States); Palmieri, Katherine [The University of Kansas Health System, Kansas City, KS (United States); Lewandowski, Christopher [Henry Ford Hospital, Detroit, MI (United States); Chang, Tiffany R. [University of Texas Medical School, Houston, TX (United States); Chang, Ira [Colorado Neurological Institute, Swedish Medical Center, Englewood, CO (United States); Rose, David Z. [Tampa General Hospital, University of South Florida College of Medicine, Tampa, FL (United States); Smith, Wade [UCSF Medical Center, San Francisco, CA (United States); Hsu, Chung Y.; Liu, Chun-Lin [China Medical University Hospital, Taichung (China); Lien, Li-Ming; Hsiao, Chen-Yu [Shin Kong Wu Ho-Su Memorial Hospital, Taipei (China); Iwama, Toru [Gifu University Hospital, Gifu (Japan); Afzal, Mohammad Rauf; Qureshi, Adnan I. [University of Minnesota, Zeenat Qureshi Stroke Research Center, Minneapolis, MN (United States); Cassarly, Christy; Hebert Martin, Renee [Medical University of South Carolina, Department of Public Health Sciences, Charleston, SC (United States); Goldstein, Joshua N. [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA (United States); Collaboration: ATACH-II and NETT Investigators

    2017-09-15

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p < 0.001). All spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion. (orig.)

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  15. Angio-CT in congenital heart disease and kidney pathology in children, preliminary report

    International Nuclear Information System (INIS)

    Biejat, A.; Zielinski, T.; Tarnowska, A.

    2004-01-01

    Due to recent development in computer tomography technique especially in the field of spiral CT, additional computer programming support for 3D reconstruction and automatic contrast media syringe systems, CT is a useful diagnostic tool in pediatric radiology in patients with congenital heart disease and kidneys pathology. Between July 2001 and June 2003 in our CT department 31 angio CT examinations were performed (19 in congenital heart disease and 12 in patients with kidneys pathology). The most important group consists patients after surgical correction of aortic coarctation (CoA)-13 cases. In the kidney pathology group the most common indication for the CT was arterial hypertension - 7 cases. CT examinations were performed using Toshiba ASTEION single - detector system with modified Rogalla et al. protocols. Regular CT scans were complemented with additional multiplane presentations and 3D and MIP reconstructions of the vessels. Original protocols were modified mostly in reduction of contrast media administration (up to 1ml/kg) and pitch increase to 1.2-1.7. Patients with heart disease in contrary to kidney pathology patients were also diagnosed with invasive procedures. In congenital heart disease group recoarctation was diagnosed in angio CT in 7 cases and in 5 cases in angiography. In remaining group CT confirmed angiography results in 3 cases (complex heart anomaly). In 2 cases of anomalous pulmonary venosus return and double aortic arch angiography confirmed CT results. In 7 cases with arterial hypertension Angio-CT revealed: nephrosclerosis in 1 case and IVC thrombosis in another. In remaining 5 cases CT results were normal. Angio-CT in pediatric patients should be performed with automatic syringes proper contrast media administration and physical parameters (mAs, kV) and can limit the indications for invasive procedures. (author)

  16. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  17. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko [Sumi Hospital, Gifu (Japan); Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu

    1995-04-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author).

  18. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    International Nuclear Information System (INIS)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko; Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu.

    1995-01-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author)

  19. A Detector for Combined SPECT/CT. Final Technical Report

    International Nuclear Information System (INIS)

    Vivek Nagarkar

    2006-01-01

    The goal of the Phase I research was to demonstrate the feasibility of developing a high performance SPECT/CT detector module based on a combination of microcolumnar CsI(Tl) scintillator coupled to an EMCCD readout. We are very pleased to report that our Phase I research has demonstrated the technical feasibility of our approach with a very high degree of success. Specifically, we were able to implement a back-thinned EMCCD with a fiberoptic window which was successfully used to demonstrate the feasibility of near simultaneous radionuclide/CT using the proposed concept. Although significantly limited in imaging area (24 x 24 mm 2 ) and pixel resolution (512 x 512), this prototype has shown exceptional capabilities such as a single optical photon sensitivity, very low noise, an intrinsic resolution of 64 (micro)m for radionuclide imaging, and a resolution in excess of 10 lp/mm for x-ray imaging. Furthermore, the combination of newly developed, thick, microcolumnar CsI and an EMCCD has shown to be capable of operating in a photon counting mode, and that the position and energy information obtained from these data can be used to improve resolution in radionuclide imaging. Finally, the prototype system has successfully been employed for near simultaneous SPECT/CT imaging using both, 125 I and 99m Tc radioisotopes. The tomographic reconstruction data obtained using a mouse heart phantom and other phantoms clearly demonstrate the feasibility and efficacy of the detector in small animal research. The following were the objectives specified in the Phase I proposal: (1) In consultation with Professor Hasegawa, develop specifications for the Phase I/Phase II prototype detector; (2) Modify current vapor deposition protocols to fabricate ∼2 mm thick microcolumnar CsI(Tl) scintillators with excellent columnar structure, high light yield, and high spatial resolution; (3) Perform detailed characterization of the film morphology, light output, and spatial resolution, and use

  20. Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, Stephan [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Department of Cardiology, Erlangen (Germany); Paul, Jean-Francois [Centre Chirurgical Marie Lannelongue, Department of Radiology, Le Plessis Robinson (France); Laurent, Francois [University of Bordeaux, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux (France); CHU de Bordeaux, Service d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Becker, Hans-Christoph [University Hospital Grosshadern, Department of Clinical Radiology, Munich (Germany); Rengo, Marco [Sapienza - University of Rome, ICOT Hospital, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Caudron, Jerome [University Hospital of Rouen, Department of Radiology, Rouen (France); Leschka, Sebastian [Saint Gallen Hospital, Department of Radiology, Saint Gallen (Switzerland); Vignaux, Olivier [Cochin Hospital, Department of Radiology, Paris (France); Knobloch, Gesine [La Charite, Department of Radiology, Berlin (Germany); Benea, Giorgio [Ospedale del Delta, Ferrara (Italy); Schlosser, Thomas [Elisabeth-Krankenhaus Hospital, Essen (Germany); Andreu, Jordi [Hospital Vall d' Hebron, Barcelona (Spain); Cabeza, Beatriz [Hospital Clinico San Carlos, Madrid (Spain); Jacquier, Alexis [La Timone Adult Hospital, Department of Radiology, Marseille (France); Souto, Miguel [Complejo Hospitalario Universitario, Santiago de Compostela (Spain); Revel, Didier [Louis Pradel Hospital, Department of Radiology, Lyon (France); Qanadli, Salah Dine [University of Lausanne, Department of Radiology, Lausanne (Switzerland); Cademartiri, Filippo [Giovanni XXIII Hospital, Department of Radiology, Monastier di Treviso (Italy); Collaboration: X-ACT Study Group

    2017-02-15

    To demonstrate non-inferiority of iobitridol 350 for coronary CT angiography (CTA) compared to higher iodine content contrast media regarding rate of patients evaluable for the presence of coronary artery stenoses. In this multicentre trial, 452 patients were randomized to receive iobitridol 350, iopromide 370 or iomeprol 400 and underwent coronary CTA using CT systems with 64-detector rows or more. Two core lab readers assessed 18 coronary segments per patient regarding image quality (score 0 = non diagnostic to 4 = excellent quality), vascular attenuation, signal and contrast to noise ratio (SNR, CNR). Patients were considered evaluable if no segment had a score of 0. Per-patient, the rate of fully evaluable CT scans was 92.1, 95.4 and 94.6 % for iobitridol, iopromide and iomeprol, respectively. Non-inferiority of iobitridol over the best comparator was demonstrated with a 95 % CI of the difference of [-8.8 to 2.1], with a pre-specified non-inferiority margin of -10 %. Although average attenuation increased with higher iodine concentrations, average SNR and CNR did not differ between groups. With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment. (orig.)

  1. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    International Nuclear Information System (INIS)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille; Liozon, Eric; Ly, Kim Heang; Lambert, Marc; Aide, Nicolas; Manrique, Alain

    2017-01-01

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  2. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    Energy Technology Data Exchange (ETDEWEB)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille [Caen University Hospital, Department of Internal Medicine, Caen (France); Liozon, Eric; Ly, Kim Heang [Limoges University Hospital, Department of Internal Medicine, Limoges (France); Lambert, Marc [Lille University Hospital, Department of Internal Medicine, Lille (France); Aide, Nicolas [Caen University Hospital, Department of Nuclear Medicine, Caen (France); INSERM U1086 ' ' ANTICIPE' ' , Francois Baclesse Cancer Centre, Caen (France); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Caen (France); Normandy University, Caen (France)

    2017-12-15

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  3. Myocardial contrast defect associated with thrombotic coronary occlusion: Pre-autopsy diagnosis of a cardiac death with post-mortem CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Park, Hye Jin; Lee, Soo Kyoung; Yang, Kyung Moo [Dept. of Forensic Medicine, National Forensic Service, Wonju (Korea, Republic of)

    2015-10-15

    We report the case of a female who died of suspected acute myocardial infarction. Post-mortem CT angiography (PMCTA) was performed with intravascular contrast infusion before the standard autopsy, and it successfully demonstrated the complete thrombotic occlusion of a coronary artery and also a corresponding perfusion defect on myocardium. We herein describe the PMCTA findings of a cardiac death with special emphasis on the potential benefits of this novel CT technique in forensic practice.

  4. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  5. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    International Nuclear Information System (INIS)

    Chandrashekhar, Guruprasadh; Sodhi, Kushaljit Singh; Saxena, Akshay Kumar; Rohit, Manoj Kumar; Khandelwal, Niranjan

    2012-01-01

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  6. Identification of the segmental artery feeding the anterior spinal artery. Correlation between helical CT and angiography

    International Nuclear Information System (INIS)

    Nishimura, Jun-ichi; Lee, Jin; Koike, Shigeomi

    2005-01-01

    We investigated whether identification of the segmental artery feeding the anterior spinal artery (ASA) is possible by single-slice helical CT. Enhanced CT and angiography were performed in 14 patients with retroperitoneal, liver, or bone tumor. A single-slice helical CT scanner with 7 mm collimation and a 1.0 helical pitch was used. Scanning was started 25 to 30 sec after an intravenous injection of 100 ml of contrast medium at a rate of 3.0 ml/sec. We predicted the segmental artery feeding the ASA in all 14 patients using enhanced CT images. In 12 of the 14 patients, the segmental artery feeding the ASA was angiographically identified. In 7 of these 12 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was the same level as that predicted by enhanced CT. In the remaining 5 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was one level higher or lower than the predicted spinal level. We could identify the segmental artery feeding the ASA by detailed examination and interpretation of single-slice helical CT images. (author)

  7. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  8. Half-dose non-contrast CT in the investigation of urolithiasis: image quality improvement with third-generation integrated circuit CT detectors.

    Science.gov (United States)

    Wang, Jun; Kang, Tony; Arepalli, Chesnal; Barrett, Sarah; O'Connell, Tim; Louis, Luck; Nicolaou, Savvakis; McLaughlin, Patrick

    2015-06-01

    The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p 0.05 for all comparisons). Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater at half-radiation dose indicating that the benefits of using novel IC detectors are greater in low and ultra-low-dose CT imaging.

  9. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  10. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography.

    Science.gov (United States)

    Tao, Shu Min; Li, Xie; Schoepf, U Joseph; Nance, John W; Jacobs, Brian E; Zhou, Chang Sheng; Gu, Hai Feng; Lu, Meng Jie; Lu, Guang Ming; Zhang, Long Jiang

    2018-04-01

    To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  12. Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Hove, Jens D; Kristensen, Thomas S

    2017-01-01

    OBJECTIVES: To test if cardiac computed tomography angiography (CCTA) can be used in the triage of patients at high risk of coronary artery disease. DESIGN: The diagnostic value of 64-detector CCTA was evaluated in 400 patients presenting with non-ST segment elevation myocardial infarction using...... invasive coronary angiography (ICA) as the reference method. The relation between the severity of disease by CCTA and a combined endpoint of death, re-hospitalization due to new myocardial infarction, or symptom-driven coronary revascularization was assessed. RESULTS: CCTA detects significant (>50...... in patients with high likelihood of coronary artery disease and could, in theory, be used to triage high risk patients. As many obstacles remain, including logistical and safety issues, our study does not support the use of CCTA as an additional diagnostic test before ICA in an all-comer NSTEMI population....

  13. Technical principles of dual source CT

    International Nuclear Information System (INIS)

    Petersilka, Martin; Bruder, Herbert; Krauss, Bernhard; Stierstorfer, Karl; Flohr, Thomas G.

    2008-01-01

    During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's 64 slice CT systems allow whole-body examinations with sub-millimeter resolution in short scan times. As an alternative to adding even more detector slices, we describe the system concept and design of a CT scanner with two X-ray tubes and two detectors (mounted on a CT gantry with a mechanical offset of 90 deg.) that has the potential to overcome limitations of conventional MDCT systems, such as temporal resolution for cardiac imaging. A dual source CT (DSCT) scanner provides temporal resolution equivalent to a quarter of the gantry rotation time, independent of the patient's heart rate (83 ms at 0.33 s rotation time). In addition to the benefits for cardiac scanning, it allows to go beyond conventional CT imaging by obtaining dual energy information if the two tubes are operated at different voltages. Furthermore, we discuss how both acquisition systems can be used to add the power reserve of two X-ray tubes for long scan ranges and obese patients. Finally, future advances of DSCT are highlighted

  14. Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

    Science.gov (United States)

    Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong

    2013-01-01

    Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583

  15. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  16. Quantification of coronary artery stenoses. Comparison of 64-slice and dual source CT angiography with cardiac catheterization

    International Nuclear Information System (INIS)

    Busch, Stephanie; Nikolaou, K.; Johnson, T.; Rist, C.; Knez, A.; Reiser, M.; Becker, C.

    2007-01-01

    Until now stenoses of the coronary arteries have been evaluated visually with CT angiography. Therefore, the results were highly dependent on subjective factors inherent in the examiner. New software tools for semiquantitative analysis (CT-QCA, quantitative coronary assessment) might be adequate to improve the diagnostic accuracy und reproducibility. CTAs of 20 patients were analyzed. Ten patients each were evaluated using 64-slice CT (64SCT) and dual source CT (DSCT) (Somatom Sensation 64 and Somatom Definition, Siemens Medical Solutions, Forchheim), respectively. Two radiologists independently evaluated the data visually and with the help of a software tool (Syngo Circulation, Siemens Medical Solutions, Forchheim). The results of the quantitative assessment of the invasive heart catheterization served as the reference standard. Sensitivity and specificity as well as the correlation coefficient, the systematic error, and the interobserver agreement (kappa) were determined. In each of both patient groups 12 stenoses were detected. For the detection of stenoses >75%, sensitivity and specificity for the visual evaluation using the 64SCT were 100% and 90%, and with the CT-QCA both were 100%. For the DSCT sensitivity and specificity were 100% for both the visual and semiautomated evaluation. The Bland-Altman plot of the results of the 64SCT showed an overestimation of 3.3% (±62.7%/56.2%) compared to the heart catheterization. The results of the DSCT exhibited an overestimation of 6.2% (±33.1%/19.8%). The interobserver agreement of the CT-QCA and the visual evaluation showed a kappa value of 0.75 and for DSCT of 1.0. The results showed a good correlation of grading stenosis between the software-assisted evaluation and the results of the coronary catheter angiography. The promising results of the DSCT are due to a superior temporal resolution compared to the 64SCT. Confirmation of these data by trials in larger patient collectives is warranted. (orig.) [de

  17. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R.; Gaetani, P.; Rodriguez y Baena, R.; Cecchini, A.; Infuso, L.

    1998-01-01

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 ± 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 ± 0.12 cm vs 1.09 ± 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients. (orig.)

  18. Comparison of four different collateral scores in acute ischemic stroke by CT angiography.

    Science.gov (United States)

    Seker, Fatih; Potreck, Arne; Möhlenbruch, Markus; Bendszus, Martin; Pham, Mirko

    2016-11-01

    Multiple scores have been described for the assessment of collateralization in acute ischemic stroke. Currently, there is no gold standard for collateral assessment by CT angiography (CTA). This study compared four frequently used collateral scores with regard to their correlation with early infarct core and mismatch ratio. 30 consecutive patients with acute occlusion of the M1 segment or terminal carotid artery were reviewed retrospectively. Collaterals were assessed using dynamic and also single-phase CTA according to grading systems by the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR), Alberta Stroke Program Early CT Score (ASPECTS) (on collaterals), Christoforidis et al and Miteff et al. The Christoforidis and ASITN/SIR scores, which were initially designed for conventional angiography, were adapted to be applicable to CTA. The scores were compared with respect to early infarct core and mismatch ratio in perfusion CT estimated by RAPID software using Spearman correlation. ASITN/SIR and ASPECTS collateral scores showed good correlation with early infarct core (rho=-0.696, p<0.001 and rho=-0.677, p<0.001) and mismatch ratio (rho=0.609, p<0.001 and rho=0.581, p<0.001). In contrast, the Christoforidis and Miteff scores correlated less well with infarct core (rho=0.245, p=0.191 and rho=-0.272, p=0.145, respectively) and mismatch ratio (rho=-0.329, p=0.075 and rho=0.279, p=0.135, respectively). ASPECTS and ASITN/SIR showed excellent cross-correlation (rho=0.901, p<0.001). Compared with the Christoforidis and Miteff scores, the modified ASITN/SIR and ASPECTS collateral scores showed consistently higher correlation with the extent of early infarct core and mismatch volume. This is probably because these scores evaluate the extent and delay of vascular enhancement in the affected territory rather than the backflow of contrast medium to the occlusion. Published by the BMJ Publishing Group Limited. For

  19. Simultaneous CT and SPECT tomography using CZT detectors

    Science.gov (United States)

    Paulus, Michael J.; Sari-Sarraf, Hamed; Simpson, Michael L.; Britton, Jr., Charles L.

    2002-01-01

    A method for simultaneous transmission x-ray computed tomography (CT) and single photon emission tomography (SPECT) comprises the steps of: injecting a subject with a tracer compound tagged with a .gamma.-ray emitting nuclide; directing an x-ray source toward the subject; rotating the x-ray source around the subject; emitting x-rays during the rotating step; rotating a cadmium zinc telluride (CZT) two-sided detector on an opposite side of the subject from the source; simultaneously detecting the position and energy of each pulsed x-ray and each emitted .gamma.-ray captured by the CZT detector; recording data for each position and each energy of each the captured x-ray and .gamma.-ray; and, creating CT and SPECT images from the recorded data. The transmitted energy levels of the x-rays lower are biased lower than energy levels of the .gamma.-rays. The x-ray source is operated in a continuous mode. The method can be implemented at ambient temperatures.

  20. Optimizing CT angiography in patients with Fontan physiology: single-center experience of dual-site power injection

    International Nuclear Information System (INIS)

    Sandler, K.L.; Markham, L.W.; Mah, M.L.; Byrum, E.P.; Williams, J.R.

    2014-01-01

    Aim: To identify adult patients with single-ventricle congenital heart disease and Fontan procedure palliation who have been misdiagnosed with or incompletely evaluated for pulmonary embolism. Additionally, this study was designed to demonstrate that simultaneous, dual-injection of contrast medium into an upper and lower extremity vein is superior to single-injection protocols for CT angiography (CTA) of the chest in this population. Materials and methods: Patients included in the study were retrospectively selected from the Adult Congenital Heart Disease (ACHD) database. Search criteria included history of Fontan palliation and available chest CT examination. Patients were evaluated for (1) type of congenital heart disease and prior operations;(2) indication for initial CT evaluation;(3) route of contrast medium administration for the initial CT examination and resulting diagnosis;(4) whether or not anticoagulation therapy was initiated; and (5) final diagnosis and treatment plan. Results: The query of the ACHD database resulted in 28 individuals or patients with Fontan palliation (superior and inferior venae cavae anastomosed to the pulmonary arteries). Of these, 19 patients with Fontan physiology underwent CTA of the pulmonary circulation, and 17 had suboptimal imaging studies. Unfortunately, seven of these 17 patients (41%) were started on anticoagulation therapy due to a diagnosis of pulmonary embolism that was later excluded. Conclusion: Patients with single-ventricle/Fontan physiology are at risk of thromboembolic disease. Therefore, studies evaluating their complex anatomy must be performed with the optimal imaging protocol to ensure diagnostic accuracy, which is best achieved with dual-injection of an upper and lower extremity central vein. - Highlights: • The adult congenital heart disease population is growing. • Many of these patients have single ventricle/Fontan physiology. • Patients with Fontan physiology are at increased risk for

  1. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    International Nuclear Information System (INIS)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan

    2007-01-01

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment

  2. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-02-15

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment.

  3. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery

    International Nuclear Information System (INIS)

    Stancanello, Joseph; Cavedon, Carlo; Francescon, Paolo; Cerveri, Pietro; Ferrigno, Giancarlo; Colombo, Federico; Perini, Stefano

    2004-01-01

    In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the 'full circle consistency test'. A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 deg. with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for

  5. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

    International Nuclear Information System (INIS)

    Rupcich, Franco; Badal, Andreu; Kyprianou, Iacovos; Schmidt, Taly Gilat

    2012-01-01

    Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360° through anthropomorphic voxelized female chest and head (0° and 30° tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI vol and multiplying by a physical CTDI vol measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30° relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are

  6. Objective image characterization of a spectral CT scanner with dual-layer detector

    Science.gov (United States)

    Ozguner, Orhan; Dhanantwari, Amar; Halliburton, Sandra; Wen, Gezheng; Utrup, Steven; Jordan, David

    2018-01-01

    This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital’s clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm-1. NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.

  7. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Latson, Larry A.; Truong, Mylene T.; Aaltonen, Eric; Shiau, Maria C.; Girvin, Francis; Alpert, Jeffrey B.; Wickstrom, Maj; Ko, Jane P.

    2016-01-01

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  8. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: bedros.taslakian@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Latson, Larry A., E-mail: larry.latson@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Truong, Mylene T., E-mail: mtruong@mdanderson.org [Department of Radiology, University of Texas, MD Anderson Cancer Center, TX (United States); Aaltonen, Eric, E-mail: Eric.Aaltonen@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Shiau, Maria C., E-mail: Maria.Shiau@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Girvin, Francis, E-mail: Francis.Girvin@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Alpert, Jeffrey B., E-mail: Jeffrey.Alpert@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Wickstrom, Maj, E-mail: Maj.Wickstrom@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Ko, Jane P., E-mail: Jane.Ko@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States)

    2016-11-15

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  9. Low tube voltage and low contrast material volume cerebral CT angiography

    International Nuclear Information System (INIS)

    Luo, Song; Zhang, Long Jiang; Lu, Guang Ming; Meinel, Felix G.; McQuiston, Andrew D.; Zhou, Chang Sheng; Qi, Li; Schoepf, U.J.

    2014-01-01

    To evaluate the image quality, radiation dose and diagnostic accuracy of low kVp and low contrast material volume cerebral CT angiography (CTA) in intracranial aneurysm detection. One hundred twenty patients were randomly divided into three groups (n = 40 for each): Group A, 70 ml iodinated contrast agent/120 kVp; group B, 30 ml/100 kVp; group C, 30 ml/80 kVp. The CT numbers, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Subjective image quality was evaluated. For patients undergoing DSA, diagnostic accuracy of CTA was calculated with DSA as reference standard and compared. CT numbers of ICA and MCA were higher in groups B and C than in group A (P < 0.01). SNR and CNR in groups A and B were higher than in group C (both P < 0.05). There was no difference in subjective image quality among the three groups (P = 0.939). Diagnostic accuracy for aneurysm detection among these groups had no statistical difference (P = 1.00). Compared with group A, the radiation dose of groups B and C was decreased by 45 % and 74 %. Cerebral CTA at 100 or 80 kVp using 30 ml contrast agent can obtain diagnostic image quality with a low radiation dose while maintaining the same diagnostic accuracy for aneurysm detection. (orig.)

  10. Musculoskeletal wide detector CT: Principles, techniques and applications in clinical practice and research

    International Nuclear Information System (INIS)

    Gondim Teixeira, Pedro Augusto; Gervaise, Alban; Louis, Matthias; Lecocq, Sophie; Raymond, Ariane; Aptel, Sabine; Blum, Alain

    2015-01-01

    Highlights: • Wide area-detector CT availability is growing steadily. • Advanced techniques such as Dynamic CT, Perfusion CT and dual energy can be used in clinical practice. • Optimal acquisition protocol is needed to increase diagnostic performance and limit dose exposure. • Guidelines for data acquisition and interpretation may increase diagnostic performance and reproducibility. - Abstract: A progressive increase in the detector width in CT scanners has meant that advanced techniques such as dynamic, perfusion and dual-energy CT are now at the radiologist's disposal. Although these techniques may be important for the diagnosis of various musculoskeletal diseases, data acquisition and interpretation can be challenging. This article offers a practical guide for the use of these tools including acquisition protocol, post-processing options and data interpretation based on 7 years of clinical experience in a tertiary university hospital

  11. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  12. Multi-sensor radiation detector system

    International Nuclear Information System (INIS)

    Foster, R.G.; Cyboron, R.D.

    1975-01-01

    The invention is a multi-sensor radiation detection system including a self-powered detector and an ion or fission chamber, preferably joined as a unitary structure, for removable insertion into a nuclear reactor. The detector and chamber are connected electrically in parallel, requiring but two conductors extending out of the reactor to external electrical circuitry which includes a load impedance, a voltage source, and switch means. The switch means are employed to alternately connect the detector and chamber either with th load impedance or with the load impedance and the voltage source. In the former orientation, current through the load impedance indicates flux intensity at the self-powered detector and in the latter orientation, the current indicates flux intensity at the detector and fission chamber, though almost all of the current is contributed by the fission chamber. (auth)

  13. Electron-beam CT coronary angiography in the patients with high heart rate arrhythmia or pacemaker

    International Nuclear Information System (INIS)

    Dong Zhi; Zhu Jiemin; Liu Zhe; Liu Junbo; Li Youjie; Qi Ji

    2006-01-01

    Objective: To report the clinical applicability of coronary angiography for patients with high heart rate, arrhythmia or cardiac pacing using the new-generation of electron-beam CT (e-Speed). Methods: EBCT (GE e-Speed) coronary angiography was performed in 36 eases (male 27, female 9, mean age 58), including the heart rate more than 90 bpm in 20 patients, frequent ectopic beats in 11 cases, implantation of cardiac pacemaker in 4 patients and the unacceptable MSCT image quality due to variability of interscan heart rate (from 82 bpm to 104 bpm) in 1 case. After volume data set was acquired using spiral mode with prospective ECG-gating, the reconstructions of MIP, CPR, VR and Cine were performed. The VR quality was evaluated using a five-point scale. Results: The quality of coronary imaging in all of 36 cases were acceptable. The total visualization rate of coronary artery branches was 80.0%. Left main, left anterior artery and right coronary artery were visualized in all patients and in 94.3% of all cases circumflex artery were visible. Conclusion: EBCT (e-Speed) is applicable in noninvasive coronary angiography for patients with high heart rate, arrhythmia or implanted cardiac pacemaker', and this examination can obtain satisfied diagnosis. (authors)

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  15. A new cone-beam X-ray CT system with a reduced size planar detector

    International Nuclear Information System (INIS)

    Li Liang; Chen Zhiqiang; Zhang Li; Xing Yuxiang; Kang Kejun

    2006-01-01

    In a traditional cone-beam CT system, the cost of product and computation is very high. The authors propose a transversely truncated cone-beam X-ray CT system with a reduced size detector positioned off-center, in which X-ray beams only cover half of the object. The reduced detector size cuts the cost and the X-ray dose of the CT system. The existing CT reconstruction algorithms are not directly applicable in this new CT system. Hence, the authors develop a BPF-type direct backprojection algorithm. Different from the traditional rebinding methods, our algorithm directly backprojects the pretreated projection data without rebinding. This makes the algorithm compact and computationally more efficient. Finally, some numerical simulations and practical experiments are done to validate the proposed algorithm. (authors)

  16. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    International Nuclear Information System (INIS)

    Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min; Rho, Ji Young; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun; White, Charles S.

    2011-01-01

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  17. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hwa Yeon; Song, In Sup (Dept. of Diagnostic Radiology Chung-Ang Univ. College of Medicine, Seoul (Korea, Republic of)); Yoo, Seung Min; Rho, Ji Young (Dept. of Diagnostic Radiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)), email: smyoo68@hanmail.net; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun (Dept. of Cardiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)); White, Charles S. (Dept. of Diagnostic Radiology Univ. of Maryland, Baltimore (United States))

    2011-05-15

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  18. Optimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy.

    Directory of Open Access Journals (Sweden)

    Chae Young Lee

    Full Text Available The purposes of this study were to optimize a proton computed tomography system (pCT for proton range verification and to confirm the pCT image reconstruction algorithm based on projection images generated with optimized parameters. For this purpose, we developed a new pCT scanner using the Geometry and Tracking (GEANT 4.9.6 simulation toolkit. GEANT4 simulations were performed to optimize the geometric parameters representing the detector thickness and the distance between the detectors for pCT. The system consisted of four silicon strip detectors for particle tracking and a calorimeter to measure the residual energies of the individual protons. The optimized pCT system design was then adjusted to ensure that the solution to a CS-based convex optimization problem would converge to yield the desired pCT images after a reasonable number of iterative corrections. In particular, we used a total variation-based formulation that has been useful in exploiting prior knowledge about the minimal variations of proton attenuation characteristics in the human body. Examinations performed using our CS algorithm showed that high-quality pCT images could be reconstructed using sets of 72 projections within 20 iterations and without any streaks or noise, which can be caused by under-sampling and proton starvation. Moreover, the images yielded by this CS algorithm were found to be of higher quality than those obtained using other reconstruction algorithms. The optimized pCT scanner system demonstrated the potential to perform high-quality pCT during on-line image-guided proton therapy, without increasing the imaging dose, by applying our CS based proton CT reconstruction algorithm. Further, we make our optimized detector system and CS-based proton CT reconstruction algorithm potentially useful in on-line proton therapy.

  19. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  20. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  1. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  2. TH-CD-207B-05: Measurement of CT Bow-Tie Profiles Using a Linear Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Yang, K; Li, X; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To accurately measure CT bow-tie profiles from various manufacturers and to provide non-proprietary information for CT system modeling. Methods: A GOS-based linear detector (0.8 mm per pixel and 51.2 cm in length) with a fast data sampling speed (0.24 ms/sample) was used to measure the relative profiles of bow-tie filters from a collection of eight CT scanners by three different vendors, GE (LS Xtra, LS VCT, Discovery HD750), Siemens (Sensation 64, Edge, Flash, Force), and Philips (iBrilliance 256). The linear detector was first calibrated for its energy response within typical CT beam quality ranges and compared with an ion chamber and analytical modeling (SPECTRA and TASMIP). A geometrical calibration process was developed to determine key parameters including the distance from the focal spot to the linear detector, the angular increment of the gantry at each data sampling, the location of the central x-ray on the linear detector, and the angular response of the detector pixel. Measurements were performed under axial-scan modes for most representative bow-tie filters and kV selections from each scanner. Bow-tie profiles were determined by re-binning the measured rotational data with an angular accuracy of 0.1 degree using the calibrated geometrical parameters. Results: The linear detector demonstrated an energy response as a solid state detector, which is close to the CT imaging detector. The geometrical calibration was proven to be sufficiently accurate (< 1mm in error for distances >550 mm) and the bow-tie profiles measured from rotational mode matched closely to those from the gantry-stationary mode. Accurate profiles were determined for a total of 21 bow-tie filters and 83 filter/kV combinations from the abovementioned scanner models. Conclusion: A new improved approach of CT bow-tie measurement was proposed and accurate bow-tie profiles were provided for a broad list of CT scanner models.

  3. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  4. Diagnostic accuracy of coronary CT angiography using 3"r"d-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    International Nuclear Information System (INIS)

    Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U.J.; Caruso, Damiano; Tesche, Christian; Steinberg, Daniel H.; Bayer, Richard R.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N.; Nikolaou, Konstantin

    2017-01-01

    To investigate diagnostic accuracy of 3"r"d-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m"2, n = 37) and B (≥30 kg/m"2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3"r"d-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  5. Ultra-high-resolution CT angiography of the artery of Adamkiewicz. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Kunihiro; Tanaka, Ryoichi; Takagi, Hidenobu [Iwate Medical University, Division of Cardiovascular Radiology, Department of Radiology, Morioka (Japan); Ueyama, Yuta; Kikuchi, Kei; Chiba, Takuya [Iwate Medical University Hospital, Center for Radiological Science, Morioka (Japan); Arakita, Kazumasa [Center for Medical Research and Development, Toshiba Medical Systems Corporation, Otawara (Japan); Schuijf, Joanne D. [Center for Medical Research and Development Europe, Toshiba Medical Systems Europe, Zoetermeer (Netherlands); Saito, Yasuo [CT Systems Development Department, Toshiba Medical Systems Corporation, Otawara (Japan)

    2018-01-15

    Preoperative identification of the artery of Adamkiewicz can help prevent postoperative spinal cord injury following thoracic and thoracoabdominal aortic repair. Several studies have demonstrated the feasibility of evaluating the artery of Adamkiewicz using multi-detector row computed tomography (CT), but precise visualization remains a challenge. The present study was conducted to evaluate the usefulness of ultra-high-resolution CT for visualizing the artery of Adamkiewicz with a slice thickness of 0.25 versus 0.5 mm in patients with aortic aneurysms. Our institutional review board approved this study. Twenty-four patients with thoracic and thoracoabdominal aneurysms were scanned with beam collimation of 0.25 mm x 128. Images were reconstructed with slice thicknesses of 0.25 and 0.5 mm. The signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) between the anterior spinal artery and spinal cord were measured. Two independent observers evaluated visualization of the artery of Adamkiewicz and its continuity between the anterior spinal artery and the aorta using a four-point scale. No significant differences in the SNR of the aorta or CNR of the anterior spinal artery were observed between 0.25- and 0.5-mm slices. The average visualization score was significantly higher for 0.25-mm slices (3.58 ± 0.78) than for 0.5-mm slices (3.13 ± 0.99) (p = 0.01). The percentage of patients with nondiagnostic image quality was significantly lower for 0.25-mm slices (8.3%) than for 0.5-mm slices (33.3%) (p = 0.03). In patients with aortic aneurysms, ultra-high-resolution CT with 0.25-mm slices significantly improves visualization of the artery of Adamkiewicz compared to 0.5-mm slices. (orig.)

  6. Comparison of quantitatively analyzed dynamic area-detector CT using various mathematic methods with FDG PET/CT in management of solitary pulmonary nodules.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2013-06-01

    The objective of our study was to prospectively compare the capability of dynamic area-detector CT analyzed with different mathematic methods and PET/CT in the management of pulmonary nodules. Fifty-two consecutive patients with 96 pulmonary nodules underwent dynamic area-detector CT, PET/CT, and microbacterial or pathologic examinations. All nodules were classified into the following groups: malignant nodules (n = 57), benign nodules with low biologic activity (n = 15), and benign nodules with high biologic activity (n = 24). On dynamic area-detector CT, the total, pulmonary arterial, and systemic arterial perfusions were calculated using the dual-input maximum slope method; perfusion was calculated using the single-input maximum slope method; and extraction fraction and blood volume (BV) were calculated using the Patlak plot method. All indexes were statistically compared among the three nodule groups. Then, receiver operating characteristic analyses were used to compare the diagnostic capabilities of the maximum standardized uptake value (SUVmax) and each perfusion parameter having a significant difference between malignant and benign nodules. Finally, the diagnostic performances of the indexes were compared by means of the McNemar test. No adverse effects were observed in this study. All indexes except extraction fraction and BV, both of which were calculated using the Patlak plot method, showed significant differences among the three groups (p method, pulmonary arterial perfusion calculated using the dual-input method, and perfusion calculated using the single-input method were significantly larger than that of SUVmax (p method (69.8%, p method has better potential for the diagnosis of pulmonary nodules than dynamic area-detector CT analyzed using other methods and than PET/CT.

  7. Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging

    International Nuclear Information System (INIS)

    Lell, M.; Anders, K.; Bautz, W.; Klotz, E.; Ditt, H.; Tomandl, B.F.

    2006-01-01

    Fifty-one patients were examined with bone subtraction CT angiography (BSCTA). Data were acquired on 4-and 64-slice spiral CT systems. The post-processing method is based on fully automatic registration of non-enhanced and contrast-enhanced CT data and subsequent selective bone removal. Vascular structures and brain tissue are retained with the original CTA noise level. Image quality and delineation of the pathologic process were assessed and artifacts introduced by the bone removal process recorded. The bone subtraction algorithm worked successfully in all examinations. The processing time was 6 min on average. Image quality was rated excellent in 20 (39%), good in 26 (51%) and acceptable in 5 (10%) patients. Ophthalmic arteries were visible in 12 (24%) patients bilaterally, in 13 (25%) patients unilaterally and in 26 (51%) patients at least at the origin. BSCTA improved visualization of the infraclinoid ICA and the vertebral arteries. The depiction of stenosis of the extracranial ICA and supraclinoid aneurysms was not significantly improved. In patients with suspicion of sinus thrombosis, BSCTA and conventional CTA yielded similar results. To conclude, BSCTA improves the visualization of vessels with close contact to bone and can improve the diagnostic accuracy and therapy planning of infraclinoid aneurysms. (orig.)

  8. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Wiesinger, Benjamin; Tepe, Gunnar; Luz, Oliver; Kopp, Andreas F.; Claussen, Claus D.; Duda, Stephan H.

    2007-01-01

    Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature. (orig.)

  9. CT Coronary Angiography vs. Coronary Artery Calcium Scoring for the Occupational Assessment of Military Aircrew.

    Science.gov (United States)

    Parsons, Iain; Pavitt, Chris; Chamley, Rebecca; d'Arcy, Jo; Nicol, Ed

    2017-02-01

    To ensure flight safety military aircrew undergo regular clinical and occupational assessment. Coronary artery calcium scoring (CACS) has been established as an imaging modality to noninvasively assess coronary artery disease (CAD). CT coronary angiography (CTCA) potentially offers a more accurate assessment of CAD, but has not been formally assessed in military aircrew. This retrospective cohort study is designed to compare the theoretical differences in downstream investigations and occupational outcomes in aircrew with suspected CAD comparing CTCA with existing CACS pathways. A 2-yr retrospective cohort study of consecutive UK military patients who underwent a CTCA and CACS was undertaken. Patient demographics, CTCA and CACS results, and initial and final occupational restrictions were analyzed comparing current UK, Canadian, and U.S. pathways. There were 44 patients who underwent CACS and CTCA. The commonest indication for a CTCA was a positive exercise ECG. Increasing CACS, stenosis severity, and stenosis burden were associated with significantly greater likelihood of occupational restriction (P = occupational restrictions. Two patients with a calcium score ≤10 had at least 1 single vessel stenosis ≥50%. A CTCA pathway is potentially a better discriminator of CAD burden in aircrew when compared with CACS and may reduce downstream testing, allowing a more efficacious approach to CAD assessment in military aircrew.Parsons I, Pavitt C, Chamley R, d'Arcy J, Nicol E. CT coronary angiography vs. coronary artery calcium scoring for the occupational assessment of military aircrew. Aerosp Med Hum Perform. 2017; 88(2):76-81.

  10. The present and future of cardiac CT in research and clinical practice. Moderated discussion and scientific debate with representatives from the four main vendors

    International Nuclear Information System (INIS)

    Dewey, M.; Vries, H. de; Vries, L. de; Haas, D.; Leidecker, C.

    2010-01-01

    Noninvasive imaging of the heart using computed tomography (CT) is an increasingly important diagnostic approach for patients with known or suspected coronary artery disease. Coronary CT angiography has recently received great attention because it provides imaging of the coronary arteries and quantification of the coronary plaque burden with a spatial and temporal resolution not available with any other noninvasive imaging test. In this moderated scientific debate we discuss the advantages and disadvantages of different technical solutions to CT imaging of the fast moving heart including its small and tortuous coronary arteries. Our discussion goes into the details of developments regarding larger Z-axis coverage (320-row volume CT, high pitch spiral acquisition), improved temporal resolution (dual-source CT, adaptive multi-segment reconstruction, and shorter gantry rotation times with air-bearing gantries), improved spatial resolution (high-definition detectors), and improved reconstruction algorithms (iterative reconstruction, cone beam reconstruction). The discussion also touches on the future technological developments that will be necessary to further improve the acceptance and widespread clinical use of cardiac CT, focusing on radiation exposure reduction and independence from heart rate. Finally, the representatives of the four main vendors explain the most important research projects regarding cardiac CT that they plan to pursue in the near future.

  11. The present and future of cardiac CT in research and clinical practice. Moderated discussion and scientific debate with representatives from the four main vendors

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, M. [Charite Berlin (Germany). Radiology; Vries, H. de [Toshiba Medical Systems Europe, Zoetermeer (Netherlands). CT; Vries, L. de [Philips Medical Systems Europe (Netherlands). CT; Haas, D. [GE Healthcare (Germany). CT; Leidecker, C. [Siemens Medical Solutions (Germany). CT

    2010-04-15

    Noninvasive imaging of the heart using computed tomography (CT) is an increasingly important diagnostic approach for patients with known or suspected coronary artery disease. Coronary CT angiography has recently received great attention because it provides imaging of the coronary arteries and quantification of the coronary plaque burden with a spatial and temporal resolution not available with any other noninvasive imaging test. In this moderated scientific debate we discuss the advantages and disadvantages of different technical solutions to CT imaging of the fast moving heart including its small and tortuous coronary arteries. Our discussion goes into the details of developments regarding larger Z-axis coverage (320-row volume CT, high pitch spiral acquisition), improved temporal resolution (dual-source CT, adaptive multi-segment reconstruction, and shorter gantry rotation times with air-bearing gantries), improved spatial resolution (high-definition detectors), and improved reconstruction algorithms (iterative reconstruction, cone beam reconstruction). The discussion also touches on the future technological developments that will be necessary to further improve the acceptance and widespread clinical use of cardiac CT, focusing on radiation exposure reduction and independence from heart rate. Finally, the representatives of the four main vendors explain the most important research projects regarding cardiac CT that they plan to pursue in the near future.

  12. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    International Nuclear Information System (INIS)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176 Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176 Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  13. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    Science.gov (United States)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  14. Multi-detector CT features of acute intestinal ischemia and their prognostic correlations.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-05-28

    Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multi-detector computed tomography (MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic information thanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software.

  15. Basics principles of flat detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kyriakou, Y.; Struffert, T.; Doerfler, A.; Kalender, W.A.

    2009-01-01

    Flat detectors (FDs) have been developed for use in radiography and fluoroscopy to replace standard X-ray film, film-screen combinations and image intensifiers (II). In comparison to X-ray film and II, FD technology offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. FDCT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. Additionally, the introduction of FD technology was a milestone for soft-tissue CT imaging in the interventional suite which was not possible with II systems in the past. This review focuses on technical and performance issues of FD technology and its wide range of applications for CT imaging. FDCT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations, but it has already proven unique for a number of dedicated CT applications offering distinct practical advantages, above all the availability of immediate CT imaging during an intervention. (orig.) [de

  16. Helical CT angiography of renal arteries: two-years of experience

    International Nuclear Information System (INIS)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L.

    1997-01-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec. Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors)

  17. Intracranial CT angiography obtained from a cerebral CT perfusion examination

    International Nuclear Information System (INIS)

    Gratama van Andel, H. A. F.; Venema, H. W.; Majoie, C. B.; Den Heeten, G. J.; Grimbergen, C. A.; Streekstra, G. J.

    2009-01-01

    CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging

  18. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    Science.gov (United States)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  19. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-01-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  20. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

    Science.gov (United States)

    Schwarz, Florian; Lange, Philipp; Zinsser, Dominik; Greif, Martin; Boekstegers, Peter; Schmitz, Christoph; Reiser, Maximilian F; Kupatt, Christian; Becker, Hans C

    2014-01-01

    To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p'sprosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.