WorldWideScience

Sample records for multi-contact cuff electrode

  1. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

    Science.gov (United States)

    Tan, Daniel W; Schiefer, Matthew A; Keith, Michael W; Anderson, J Robert; Tyler, Dustin J

    2015-04-01

    Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. Multi-contact cuff electrodes were implanted in the median, ulnar, and radial nerves of the upper-limb. Nerve stimulation produced a selective sensory response on 19 of 20 contacts and 16 of 16 contacts in subjects 1 and 2, respectively. Stimulation elicited multiple, distinct percept areas on the phantom and residual limb. Consistent threshold, impedance, and percept areas have demonstrated that the neural interface is stable for the duration of this on-going, chronic study. We have achieved selective nerve response from multi-contact cuff electrodes by demonstrating characteristic percept areas and thresholds for each contact. Selective sensory response remains consistent in two upper-limb amputees for 1 and 2 years, the longest multi-contact sensory feedback system to date. Our approach demonstrates selectivity and stability can be achieved through an extraneural interface, which can provide sensory feedback to amputees.

  2. Effect of contacts configuration and location on selective stimulation of cuff electrode.

    Science.gov (United States)

    Taghipour-Farshi, Hamed; Frounchi, Javad; Ahmadiasl, Nasser; Shahabi, Parviz; Salekzamani, Yaghoub

    2015-01-01

    Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configurations for contacts to be implemented in cuff, monopolar and tripolar. A cuff electrode with tripolar configuration can restrict the activation to a more localized region within a nerve trunk compared to a cuff with monopolar configuration and improve the selectivity. Anode contacts in tripolar configuration can be made in two structures, "ring" and "dot". In this study, the stimulation capabilities of these two structures were evaluated. The recruitment properties and the selectivity of stimulation were examined by measuring the electric potential produced by stimulation currents. The results of the present study indicated that using dot configuration, the current needed to stimulate fascicles in tripolar topologies would be reduced by 10%. It was also shown that stimulation threshold was increased by moving anode contacts inward the cuff. On the other hand, stimulation threshold was decreased by moving the anode contacts outward the cuff which would decrease selectivity, too. We conclude that dot configuration is a better choice for stimulation. Also, a cuff inward placement of 10% relative to the cuff length was near optimal.

  3. Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes.

    Science.gov (United States)

    Tarler, Matthew D; Mortimer, J Thomas

    2003-09-01

    Using a self-sizing spiral-cuff electrode placed on the sciatic nerve of the cat, the joint torque evoked with stimulation applied to contacts in a monopolar configuration was judged to be the same as the torque evoked by stimulation applied to contacts in a tripolar configuration. Experiments were carried out in six acute cat preparations. In each experiment, a 12-contact electrode was placed on the sciatic nerve and used to effect both the monopolar and tripolar electrode configurations. The ankle torque produced by electrically evoked isometric muscle contraction was measured in three dimensions: plantar flexion, internal rotation, and inversion. Based on the recorded ankle torque, qualitative and quantitative comparisons were performed to determine if any significant difference existed in the pattern or order in which motor nerve fibers were recruited. No significant difference was found at a 98% confidence interval in either the recruitment properties or the repeatability of the monopolar and tripolar configurations. Further, isolated activation of single fascicles within the sciatic nerve was observed. Once nerve fibers in a fascicle were activated, recruitment of that fascicle was modulated over the full range before "spill-over" excitation occurred in neighboring fascicles. These results indicate that a four contact, monopolar nerve-cuff electrode is a viable substitute for a 12 contact, tripolar nerve-cuff electrode. The results of this study are also consistent with the hypothesis that multicontact self-sizing spiral-cuff electrodes can be used in motor prostheses to provide selective control of many muscles. These findings should also apply to other neuroprostheses employing-cuff electrodes on nerve trunks.

  4. An improved method of crafting a multi-electrode spiral cuff for the selective.

    Science.gov (United States)

    Rozman, Janez; Pečlin, Polona; Ribarič, Samo; Godec, Matjaž; Burja, Jaka

    2018-01-17

    This article reviews an improved methodology and technology for crafting a multi-electrode spiral cuff for the selective activation of nerve fibres in particular superficial regions of a peripheral nerve. The analysis, structural and mechanical properties of the spot welds used for the interconnections between the stimulating electrodes and stainless-steel lead wires are presented. The cuff consisted of 33 platinum electrodes embedded within a self-curling 17-mm-long silicone spiral sheet with a nominal internal diameter of 2.5 mm. The weld was analyzed using scanning electron microscopy and nanohardness tests, while the interconnection was investigated using destructive load tests. The functionality of the cuff was tested in an isolated porcine vagus nerve. The results of the scanning electron microscopy show good alloying and none of the typical welding defects that occur between the wire and the platinum foil. The results of the destructive load tests show that the breaking loads were between 3.22 and 5 N. The results of the nanohardness testing show that the hardness of the weld was different for the particular sites on the weld sample. Finally, the results of the functional testing show that for different stimulation intensities both the compound action potential deflection and the shape are modulated.

  5. Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys

    Science.gov (United States)

    Brill, N. A.; Naufel, S. N.; Polasek, K.; Ethier, C.; Cheesborough, J.; Agnew, S.; Miller, L. E.; Tyler, D. J.

    2018-06-01

    Objective. The objective of this work was to evaluate whether nerve cuffs can selectively activate hand muscles for functional electrical stimulation (FES). FES typically involves identifying and implanting electrodes in many individual muscles, but nerve cuffs only require implantation at a single site around the nerve. This method is surgically more attractive. Nerve cuffs may also more effectively stimulate intrinsic hand muscles, which are difficult to implant and stimulate without spillover to adjacent muscles. Approach. To evaluate its ability to selectively activate muscles, we implanted and tested the flat interface nerve electrode (FINE), which is designed to selectively stimulate peripheral nerves that innervate multiple muscles (Tyler and Durand 2002 IEEE Trans. Neural Syst. Rehabil. Eng. 10 294-303). We implanted FINEs on the nerves and bipolar intramuscular wires for recording compound muscle action potentials (CMAPs) from up to 20 muscles in each arm of six monkeys. We then collected recruitment curves while the animals were anesthetized. Main result. A single FINE implanted on an upper extremity nerve in the monkey can selectively activate muscles or small groups of muscles to produce multiple, independent hand functions. Significance. FINE cuffs can serve as a viable supplement to intramuscular electrodes in FES systems, where they can better activate intrinsic and extrinsic muscles with lower currents and less extensive surgery.

  6. Solid-contact pH-selective electrode using multi-walled carbon nanotubes.

    Science.gov (United States)

    Crespo, Gastón A; Gugsa, Derese; Macho, Santiago; Rius, F Xavier

    2009-12-01

    Multi-walled carbon nanotubes (MWCNT) are shown to be efficient transducers of the ionic-to-electronic current. This enables the development of a new solid-contact pH-selective electrode that is based on the deposition of a 35-microm thick layer of MWCNT between the acrylic ion-selective membrane and the glassy carbon rod used as the electrical conductor. The ion-selective membrane was prepared by incorporating tridodecylamine as the ionophore, potassium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate as the lipophilic additive in a polymerized methylmethacrylate and an n-butyl acrylate matrix. The potentiometric response shows Nernstian behaviour and a linear dynamic range between 2.89 and 9.90 pH values. The response time for this electrode was less than 10 s throughout the whole working range. The electrode shows a high selectivity towards interfering ions. Electrochemical impedance spectroscopy and chronopotentiometry techniques were used to characterise the electrochemical behaviour and the stability of the carbon-nanotube-based ion-selective electrodes.

  7. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  8. Electrode-Skin contact impedance: In vivo measurements on an ovine model

    International Nuclear Information System (INIS)

    Nguyen, D T; Kosobrodov, R; Jin, C; McEwan, A; Barry, M A; Chik, W; Thiagalingam, A; Oh, T I

    2013-01-01

    The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of an ovine model. The study has been approved by the Westmead Hospital Animal Ethics Committee. The electrode models that were employed in the research are Ag/AgCl electrodes (E1), commonly used for ECG and EIT measurements in both humans and animal models, stainless steel crocodile clips (E2), typically used on animal models, and novel multi-point dry electrodes in two modifications: bronze plated (E3) and nickel plated (E4). Further, since the contact impedance is mostly attributed to the acellular outer layer of the skin, in our experiment, we attempted to study the effect of this layer by comparing the results when the skin is intact and when electrodes are introduced underneath the skin through small cuts. This boundary effect was assessed by comparison of measurements obtained during E2 skin surface contact, and sub-cutaneous contact (E5). Twelve gauge intradermal needles were also tested as an electrode (E6). The full impedance spectrum, from 500 Hz to 300 kHz, was recorded, analysed and compared. As expected, the contact impedance in the more invasive cases, i.e the electrodes under the skin, is significantly lower than in the non-invasive cases. At the frequency of 50 kHz which is commonly used in lung EIT acquisition, electrodes E3, E4 and E6 demonstrated contact impedance of less than 200 Ω, compared to more than 400 Ω measured for electrodes E1, E2 and E5. In conclusion, the novel multipoint electrodes proved to be best suited for EIT purposes, because they are non-invasive and have lower contact impedance than Ag/AgCl and crocodile clips, in both invasive and

  9. Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer.

    Science.gov (United States)

    Sabetian, Parisa; Sadeghlo, Bita; Zhang, Chengran Harvey; Yoo, Paul B

    2017-02-01

    Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely attributed to artifact noise signals that contaminate the recorded neural activity. In this study, we investigated the use of a conductive shield layer (CSL) as a means of reducing the artifact noise recorded by nerve cuff electrodes. Using both computational simulations and in vivo experiments, we found that the CSL can result in up to an 85% decrease in the recorded artifact signal. Both the electrical conductivity and the surface area of the CSL were identified as important design criteria. Although this study shows that the CSL can significantly reduce artifact noise in tripolar nerve cuff electrodes, long-term implant studies are needed to validate our findings. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    Science.gov (United States)

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. An implantable CMOS signal conditioning system for recording nerve signals with cuff electrodes

    DEFF Research Database (Denmark)

    Papathanasiou, Konstantinos; Lehmann, Torsten

    2000-01-01

    We propose a system architecture for recording nerve signals with cuff electrodes and develop the key component in this system, the small-input, low-noise, low-power, high-gain amplifier. The amplifier is implemented using a mixture of weak- and strong-inversion transistors and a special off-set ......-set compensation technique; its performance is validated using Spice simulations....

  12. Nonlocal laser annealing to improve thermal contacts between multi-layer graphene and metals

    International Nuclear Information System (INIS)

    Ermakov, Victor A; Alaferdov, Andrei V; Vaz, Alfredo R; Moshkalev, Stanislav A; Baranov, Alexander V

    2013-01-01

    The accuracy of thermal conductivity measurements by the micro-Raman technique for suspended multi-layer graphene flakes has been shown to depend critically on the quality of the thermal contacts between the flakes and the metal electrodes used as the heat sink. The quality of the contacts can be improved by nonlocal laser annealing at increased power. The improvement of the thermal contacts to initially rough metal electrodes is attributed to local melting of the metal surface under laser heating, and increased area of real metal–graphene contact. Improvement of the thermal contacts between multi-layer graphene and a silicon oxide surface was also observed, with more efficient heat transfer from graphene as compared with the graphene–metal case. (paper)

  13. Transverse versus longitudinal tripolar configuration for selective stimulation with multipolar cuff electrodes.

    Science.gov (United States)

    Nielsen, Thomas N; Kurstjens, G A Mathijs; Struijk, Johannes J

    2011-04-01

    The ability to stimulate subareas of a nerve selectively is highly desirable, since it has the potential of simplifying surgery to implanting one cuff on a large nerve instead of many cuffs on smaller nerves or muscles, or alternatively can improve function where surgical access to the smaller nerves is limited. In this paper, stimulation was performed with a four-channel multipolar cuff electrode implanted on the sciatic nerve of nine rabbits to compare the extensively researched longitudinal tripolar configuration with the transverse tripolar configuration, which has received less interest. The performance of these configurations was evaluated in terms of selectivity in recruitment of the three branches of the sciatic nerve. The results showed that the transverse configuration was able to selectively activate the sciatic nerve branches to a functionally relevant level in more cases than the longitudinal configuration (20/27 versus 11/27 branches) and overall achieved a higher mean selectivity [0.79 ± 0.13 versus 0.61 ± 0.09 (mean ± standard deviation)]. The transverse configuration was most successful at recruiting the small cutaneous and medium-sized peroneal branches, and less successful at recruiting the large tibial nerve.

  14. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    Science.gov (United States)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  15. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    International Nuclear Information System (INIS)

    O’Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-01-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact.This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface. (paper)

  16. Conformally encapsulated multi-electrode arrays with seamless insulation

    Energy Technology Data Exchange (ETDEWEB)

    Tabada, Phillipe J.; Shah, Kedar G.; Tolosa, Vanessa; Pannu, Satinderall S.; Tooker, Angela; Delima, Terri; Sheth, Heeral; Felix, Sarah

    2016-11-22

    Thin-film multi-electrode arrays (MEA) having one or more electrically conductive beams conformally encapsulated in a seamless block of electrically insulating material, and methods of fabricating such MEAs using reproducible, microfabrication processes. One or more electrically conductive traces are formed on scaffold material that is subsequently removed to suspend the traces over a substrate by support portions of the trace beam in contact with the substrate. By encapsulating the suspended traces, either individually or together, with a single continuous layer of an electrically insulating material, a seamless block of electrically insulating material is formed that conforms to the shape of the trace beam structure, including any trace backings which provide suspension support. Electrical contacts, electrodes, or leads of the traces are exposed from the encapsulated trace beam structure by removing the substrate.

  17. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  18. DBS Electrodes With Single Disconnected Contacts: Long-Term Observation and Implications for the Management.

    Science.gov (United States)

    Allert, Niels; Jusciute, Egle; Quindt, Regina; Lindlau, Alexandra; Nolden, Brit Meike; Daryaeitabar, Mohammadreza; Karbe, Hans

    2018-04-27

    To evaluate the long-term course of quadripolar DBS electrodes with disconnected single contacts that cannot be used for DBS. Quadripolar electrodes with open circuits of single contacts or monopolar impedances >6500 Ω were identified from a cohort of 2082 electrodes from 1044 patients with variable movement disorders. The long-term course was analyzed from follow-up data. Disconnected contacts were found in 58 electrodes (2.8%) from 49 patients (4.7%). The dysfunction was restricted to one contact in 51 electrodes (87.9%), two contacts in 5 electrodes (8.6%), three contacts in 2 electrodes (3.4%). Onset was related to surgery (implantation, impulse generator replacement, or other surgical revision) in 34 electrodes (58.6%), trauma in 2 electrodes, undetermined in 11 electrodes, and occurred spontaneously after previous normal measurements in 11 electrodes (19.0%). Repeated measurements at follow-ups of ≥3 months were available in 39 electrodes. In 16 electrodes (41.0%) abnormal impedances persisted constantly during observations up to 11½ years (47 ± 35 months, median 41 months). In 21 electrodes (53.8%) abnormal impedances remained restricted to the initial contact(s) but varied considerably between measurements during up to six years (39 ± 18 months, median 38 months). Only two electrodes (5.1%) with initially one disconnected contact developed a disconnection of a second contact. Disconnections of single contacts occur with increasing cumulative incidence during long-term DBS. Surgery is the main causative risk factor. In the majority of electrodes, the dysfunction remains restricted to the initial contact(s). © 2018 International Neuromodulation Society.

  19. Chronic implantation of cuff electrodes on the pelvic nerve in rats is well tolerated and does not compromise afferent or efferent fibre functionality

    Science.gov (United States)

    Crook, J. J.; Brouillard, C. B. J.; Irazoqui, P. P.; Lovick, T. A.

    2018-04-01

    Objective. Neuromodulation of autonomic nerve activity to regulate physiological processes is an emerging field. Vagal stimulation has received most attention whereas the potential of modulate visceral function by targeting autonomic nerves within the abdominal cavity remains under-exploited. Surgery to locate intra-abdominal targets is inherently more stressful than for peripheral nerves. Electrode leads risk becoming entrapped by intestines and loss of functionality in the nerve-target organ connection could result from electrode migration or twisting. Since nociceptor afferents are intermingled with similar-sized visceral autonomic fibres, stimulation may induce pain. In anaesthetised rats high frequency stimulation of the pelvic nerve can suppress urinary voiding but it is not known how conscious animals would react to this procedure. Our objective therefore was to determine how rats tolerated chronic implantation of cuff electrodes on the pelvic nerve, whether nerve stimulation would be aversive and whether nerve-bladder functionality would be compromised. Approach. We carried out a preliminary de-risking study to investigate how conscious rats tolerated chronic implantation of electrodes on the pelvic nerve, their responsiveness to intermittent high frequency stimulation and whether functionality of the nerve-bladder connection became compromised. Main results. Implantation of cuff electrodes was well-tolerated. The normal diurnal pattern of urinary voiding was not disrupted. Pelvic nerve stimulation (up to 4 mA, 3 kHz) for 30 min periods evoked mild alerting at stimulus onset but no signs of pain. Stimulation evoked a modest (nerve temperature but the functional integrity of the nerve-bladder connection, reflected by contraction of the detrusor muscle in response to 10 Hz nerve stimulation, was not compromised. Significance. Chronic implantation of cuff electrodes on the pelvic nerve was found to be a well-tolerated procedure in rats and high frequency

  20. Improving Single-Carbon-Nanotube-Electrode Contacts Using Molecular Electronics.

    Science.gov (United States)

    Krittayavathananon, Atiweena; Ngamchuea, Kamonwad; Li, Xiuting; Batchelor-McAuley, Christopher; Kätelhön, Enno; Chaisiwamongkhol, Korbua; Sawangphruk, Montree; Compton, Richard G

    2017-08-17

    We report the use of an electroactive species, acetaminophen, to modify the electrical connection between a carbon nanotube (CNT) and an electrode. By applying a potential across two electrodes, some of the CNTs in solution occasionally contact the electrified interface and bridge between two electrodes. By observing a single CNT contact between two microbands of an interdigitated Au electrode in the presence and absence of acetaminophen, the role of the molecular species at the electronic junction is revealed. As compared with the pure CNT, the current magnitude of the acetaminophen-modified CNTs significantly increases with the applied potentials, indicating that the molecule species improves the junction properties probably via redox shuttling.

  1. Pronounced Photovoltaic Response from Multi-layered MoTe2 Phototransistor with Asymmetric Contact Form.

    Science.gov (United States)

    Liu, Junku; Guo, Nan; Xiao, Xiaoyang; Zhang, Kenan; Jia, Yi; Zhou, Shuyun; Wu, Yang; Li, Qunqing; Xiao, Lin

    2017-11-22

    In this study, we fabricate air-stable p-type multi-layered MoTe 2 phototransistor using Au as electrodes, which shows pronounced photovoltaic response in off-state with asymmetric contact form. By analyzing the spatially resolved photoresponse using scanning photocurrent microscopy, we found that the potential steps are formed in the vicinity of the electrodes/MoTe 2 interface due to the doping of the MoTe 2 by the metal contacts. The potential step dominates the separation of photoexcited electron-hole pairs in short-circuit condition or with small V sd biased. Based on these findings, we infer that the asymmetric contact cross-section between MoTe 2 -source and MoTe 2 -drain electrodes is the reason to form non-zero net current and photovoltaic response. Furthermore, MoTe 2 phototransistor shows a faster response in short-circuit condition than that with higher biased V sd within sub-millisecond, and its spectral range can be extended to the infrared end of 1550 nm.

  2. High conductivity and transparent aluminum-based multi-layer source/drain electrodes for thin film transistors

    Science.gov (United States)

    Yao, Rihui; Zhang, Hongke; Fang, Zhiqiang; Ning, Honglong; Zheng, Zeke; Li, Xiaoqing; Zhang, Xiaochen; Cai, Wei; Lu, Xubing; Peng, Junbiao

    2018-02-01

    In this study, high conductivity and transparent multi-layer (AZO/Al/AZO-/Al/AZO) source/drain (S/D) electrodes for thin film transistors were fabricated via conventional physical vapor deposition approaches, without toxic elements or further thermal annealing process. The 68 nm-thick multi-layer films with excellent optical properties (transparency: 82.64%), good electrical properties (resistivity: 6.64  ×  10-5 Ω m, work function: 3.95 eV), and superior surface roughness (R q   =  0.757 nm with scanning area of 5  ×  5 µm2) were fabricated as the S/D electrodes. Significantly, comprehensive performances of AZO films are enhanced by the insertion of ultra-thin Al layers. The optimal transparent TFT with this multi-layer S/D electrodes exhibited a decent electrical performance with a saturation mobility (µ sat) of 3.2 cm2 V-1 s-1, an I on/I off ratio of 1.59  ×  106, a subthreshold swing of 1.05 V/decade. The contact resistance of AZO/Al/AZO/Al/AZO multi-layer electrodes is as low as 0.29 MΩ. Moreover, the average visible light transmittance of the unpatterned multi-layers constituting a whole transparent TFT could reach 72.5%. The high conductivity and transparent multi-layer S/D electrodes for transparent TFTs possessed great potential for the applications of the green and transparent displays industry.

  3. Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and IrOx films deposited by RF sputtering

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Jung, Jung Hwan; Chae, Youn Mee; Kang, Ji Yoon; Suh, Jun-Kyo Francis

    2010-01-01

    This paper presents the fabrication and characterization of implantable and flexible nerve cuff electrodes for neural interfaces using the conventional BioMEMS technique. In order to fabricate a flexible nerve electrode, polyimide (PI) was chosen as the substrate material. Then, nerve electrodes were thermally re-formed in a cuff shape so as to increase the area in which the charges were transferred to the nerve. Platinum (Pt), iridium (Ir) and iridium oxide (IrO x ) films, which were to serve as conducting materials for the nerve electrodes, were deposited at different working pressures by RF magnetron sputtering. The electrochemical properties of the deposited films were characterized by electrochemical impedance spectroscopy (EIS). The charge delivery capacities of the films were recorded and calculated by cyclic voltammetry (CV). The deposited films of Pt, Ir and IrO x have strong differences in electrochemical properties, which depend on the working pressure of sputter. Each film deposited at 30 mTorr of working pressure shows the highest value of charge delivery capacity (CDC). For the IrO x films, the electrochemical properties were strongly affected by the working pressure as well as the Ar:O 2 gas ratio. The IrO x film deposited with an Ar:O 2 gas ratio of 8:1 showed the highest CDC of 59.5 mC cm −2 , which was about five times higher than that of films deposited with a 1:1 gas ratio.

  4. Technique eliminates high voltage arcing at electrode-insulator contact area

    Science.gov (United States)

    Mealy, G.

    1967-01-01

    Coating the electrode-insulator contact area with silver epoxy conductive paint and forcing the electrode and insulator tightly together into a permanent connection, eliminates electrical arcing in high-voltage electrodes supplying electrical power to vacuum facilities.

  5. Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG.

    Science.gov (United States)

    Liu, Jing; Li, Yao; Ding, Xiao-Rong; Dai, Wen-Xuan; Zhang, Yuan-Ting

    2015-01-01

    Pulse transit time (PTT), which refers to the time it takes a pulse wave to travel between two arterial sites is a promising index for cuff-less blood pressure (BP) estimation, as well as non-invasive assessment of arterial functions. However, it has not been investigated whether PTTs measured from ECG and different wavelength PPG are equally affected by the arterial status. Furthermore, comparison between the changes of different PTTs can provide enlightenment on the hardware implementation of the PTT-based BP estimation method. This work mainly studied the changes of PTTs calculated from electrocardiogram (ECG) and multi-wavelength photoplethysmogram (PPG) after exerting cuff pressure on the upper arm. A four-channel PPG acquisition system was developed to collect the multi-wavelength PPG signals of red, yellow, green and blue light at the fingertip simultaneously. Ten subjects participated in the experiment and their PTTs measured from different PPG and ECG signals before and after exerting cuff pressure were compared. This study found that within one minute after the four-minute cuff inflation and deflation process, the PTT measured from ECG and yellow PPG experienced a significant increase (p0.9) compared with that before exerting cuff pressure. This indicates that PTTs calculated from different wavelength PPG have different recoverability from smooth muscle relaxation. Another interesting finding is that the PTT calculated from ECG and yellow PPG had a strong correlation (|r|>0.7) with the time difference between yellow PPG and other PPG signals, which implies the potential of the time difference between yellow PPG and other PPGs as a complementary to PTT-based model for blood pressure estimation.

  6. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

    Science.gov (United States)

    Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan

    2017-12-21

    Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  7. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode

    Directory of Open Access Journals (Sweden)

    Ahnsei Shon

    2017-12-01

    Full Text Available Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC-compliant power transmission circuit, a medical implant communication service (MICS-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  8. Large/Massive Tears, Fatty Infiltration, and Rotator Cuff Muscle Atrophy: A Review Article With Management Options Specific to These Types of Cuff Deficiencies

    OpenAIRE

    Gandhi Nathan Solayar; Bradley Seeto; Darren Chen; Samuel Mac Dessi

    2016-01-01

    Context There are many studies in the literature looking into factors affecting outcomes in rotator cuff surgery. The aetiology of rotator cuff deficiency is often multi-factorial and there are many facets towards successful management in this often debilitating condition. Evidence Acquisition We performed a literature search of MEDLINE and Embase databases using the terms large rotator cuff tears, fatty infiltration rotator cuff,...

  9. Flexible electrode belt for EIT using nanofiber web dry electrodes.

    Science.gov (United States)

    Oh, Tong In; Kim, Tae Eui; Yoon, Sun; Kim, Kap Jin; Woo, Eung Je; Sadleir, Rosalind J

    2012-10-01

    Efficient connection of multiple electrodes to the body for impedance measurement and voltage monitoring applications is of critical importance to measurement quality and practicality. Electrical impedance tomography (EIT) experiments have generally required a cumbersome procedure to attach the multiple electrodes needed in EIT. Once placed, these electrodes must then maintain good contact with the skin during measurements that may last several hours. There is usually also the need to manage the wires that run between the electrodes and the EIT system. These problems become more severe as the number of electrodes increases, and may limit the practicality and portability of this imaging method. There have been several trials describing human-electrode interfaces using configurations such as electrode belts, helmets or rings. In this paper, we describe an electrode belt we developed for long-term EIT monitoring of human lung ventilation. The belt included 16 embossed electrodes that were designed to make good contact with the skin. The electrodes were fabricated using an Ag-plated PVDF nanofiber web and metallic threads. A large contact area and padding were used behind each electrode to improve subject comfort and reduce contact impedances. The electrodes were incorporated, equally spaced, into an elasticated fabric belt. We tested the electrode belt in conjunction with the KHU Mark1 multi-frequency EIT system, and demonstrate time-difference images of phantoms and human subjects during normal breathing and running. We found that the Ag-plated PVDF nanofiber web electrodes were suitable for long-term measurement because of their flexibility and durability. Moreover, the contact impedance and stability of the Ag-plated PVDF nanofiber web electrodes were found to be comparable to similarly tested Ag/AgCl electrodes.

  10. Arthroscopic rotator cuff repair in elite rugby players

    OpenAIRE

    Tambe, Amol; Badge, Ravi; Funk, Lennard

    2009-01-01

    Background: Rugby is an increasingly popular collision sport. A wide spectrum of injuries can be sustained during training and match play. Rotator cuff injury is uncommon in contact sports and there is little published literature on the treatment of rotator cuff tears in rugby players. Aims: We therefore reviewed the results and functional outcomes of arthroscopic rotator cuff repair in elite rugby players. Materials and Methods: Eleven professional rugby players underwent arthroscopic ...

  11. The "Parachute" Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint.

    Science.gov (United States)

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-10-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.

  12. Design, simulation and characterization of a MEMS inertia switch with flexible CNTs/Cu composite array layer between electrodes for prolonging contact time

    International Nuclear Information System (INIS)

    Wang, Yang; Yang, Zhuoqing; Xu, Qiu; Chen, Wenguo; Ding, Guifu; Zhao, Xiaolin

    2015-01-01

    This paper reports an inertia switch with a flexible carbon nanotubes/copper (CNTs/Cu) composite array layer between movable and fixed electrodes, which achieves a longer contact time compared to the traditional design using rigid-to-rigid impact between electrodes. The CNTs/Cu layer is fabricated using the composite electroplating method, and the whole device is completed by multi-layer metal electroplating based on the micro-electro-mechanical systems (MEMS) process. The dynamic responses of the designed inertia switch and the contact impact between a single CNT and a fixed electrode/another CNT have both been simulated by the ANSYS finite-element-method (FEM). It is shown that the contact time of the designed inertia switch is about 100 µs under the applied 80 g half-sine-shaped acceleration in the sensing direction. Finally, the fabricated MEMS inertia switch with the flexible CNTs/Cu composite array layer between electrodes has been evaluated by a dropping hammer system. The test contact time is about112 µs, which has a good agreement with the simulation and is much longer than that of the traditional design. (paper)

  13. Fabrication and electrochemical characterization of multi-walled carbon nanotube electrodes for applications to nano-electrochemical sensing

    International Nuclear Information System (INIS)

    Hwang, Sookhyun; Choi, Hyonkwang; Jeon, Minhyon; Vedala, Harindra; Kim, Taehyung; Choi, Wonbong

    2010-01-01

    In this study, we fabricated and electrochemically characterized two types of individual carbon nanotube electrodes: an as-produced multi-walled carbon nanotube (MWNT) electrode and a modified MWNT electrode. As-produced MWNTs were electrically contacted with Au/Ti layers by using nanolithography and RF magnetron sputtering. Open-ended modified MWNT electrodes were fabricated by using a reactive ion etching treatment under an oxygen atmosphere. We also performed cyclic voltammetry measurements to detect aqueous dopamine solutions with different concentrations. We found that an individual MWNT electrode, which had a small effective area, showed good electrochemical performance. The electrocatalytic behavior of the modified electrode, which had 'broken' open ends were better than that of the as-produced electrode with respect to sensitivity. The modified electrode was capable of detecting dopamine at the picomolar level. Therefore, an individual modified MWNT electrode has potential for applications to active components in nanobiosensors.

  14. Combined electric and pressure cuff pain stimuli for assessing conditioning pain modulation (CPM).

    Science.gov (United States)

    Tsukamoto, M; Petersen, K K; Mørch, C D; Arendt-Nielsen, L

    2017-12-29

    Aims Traditionally, conditioning pain modulation (CPM) can be assessed by applying a test stimulus (TS) before and after application of a conditioning stimulus (CS), which is normally applied extra-segmental. Currently, no studies have attempted to apply the TS and CS to the same site using different stimuli modalities. The aim of this study was to evaluate electrical TS and cuff pressure CS applied to the same experimental site for studying CPM. Methods 20 male volunteers participated in this study, which consisted of stimulations applied by a cuff-algometer (NociTech and Aalborg University, Denmark) and current stimulator (Digitimer DS5, UK), through two Ag/AgCl electrodes (Ambu® Neuroline 700, Denmark). The cuff was wrapped around the lower leg and stimulation electrodes were placed under the cuff and to the same location on the contralateral leg. Electrical TS were applied to the non-dominant leg with or without cuff pressure CS on the dominant (CS1) or the same (non-dominant) leg (CS2, electrode under cuff). The subjects were instructed to rate the electrical evoked pain intensity on a 10-cm continuous visual analog scale (VAS, "0" represented "no pain", and "10" represented "maximal pain"). The pain detection threshold (PDT) was defined as "1" on the VAS scale. Results There was no significant deference in PDT for neither CS1 nor CS2. A median split subanalysis on CPM-responders versus CPM-nonresponders to the TS + CS1 combination. Using this grouping, there was significant increase in PDT when comparing TS to TS + CS1 or TS + CS2 (4.0 mA vs 5.6 mA; P CPM can be evoked in a subgroup of subjects by applying the electrical test stimulus and cuff pressure conditioning stimuli to the same experimental site.

  15. Flexible multichannel vagus nerve electrode for stimulation and recording for heart failure treatment.

    Science.gov (United States)

    Xue, Ning; Martinez, Ignacio Delgado; Sun, Jianhai; Cheng, Yuhua; Liu, Chunxiu

    2018-07-30

    Vagus nerve stimulation is an emerging bioelectronic medicine to modulate cardiac function, as the nerve provides parasympathetic innervation to the heart. In this study, we developed a polyimide based 2D cuff electrode to wrap around on the vagus nerve. Thanks to the tiny size and bendable protruding structure of the contact tips of the device, the electrode sites are able to flexibly bend to touch the nerve, selectively record and stimulate the vagus nerve. Gold, platinum and platinum black materials were chosen to compose the electrodes for nerve stimulation and recording, respectively. Since the platinum black has ~30 times larger charge delivery capacity (CDC) than gold, Pt black electrode is used for nerve stimulation. The electrochemical impedance spectroscopy and cyclic voltammetry measurement of the three materials were conducted in vitro, revealing the results of 405 kΩ, 41 kΩ, 10.5 kΩ, @1 kHz and 0.81 mC/cm 2 , 4.26 mC/cm 2 , 25.5 mC/cm 2 , respectively (n = 3). The cuff electrodes were implanted into the right-sided vagus nerve of rats for in vivo experiment. Biphasic current configuration was implemented for nerve stimulation with frequency of 10 Hz, pulse during of 300 μs and various currents stimulus. The result shows the heart beat frequency drops up to 36% during the stimulation and was able to return the regular frequency as stimulation was removed. Subsequently, the vagus nerve signals were recorded with the four channel cuff electrodes. The magnitude of the compound nerve action potentials (CNAPs) is ~10 μV and the signal to noise ratio (SNR) is ~20. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Restoring speech perception with cochlear implants by spanning defective electrode contacts.

    Science.gov (United States)

    Frijns, Johan H M; Snel-Bongers, Jorien; Vellinga, Dirk; Schrage, Erik; Vanpoucke, Filiep J; Briaire, Jeroen J

    2013-04-01

    Even with six defective contacts, spanning can largely restore speech perception with the HiRes 120 speech processing strategy to the level supported by an intact electrode array. Moreover, the sound quality is not degraded. Previous studies have demonstrated reduced speech perception scores (SPS) with defective contacts in HiRes 120. This study investigated whether replacing defective contacts by spanning, i.e. current steering on non-adjacent contacts, is able to restore speech recognition to the level supported by an intact electrode array. Ten adult cochlear implant recipients (HiRes90K, HiFocus1J) with experience with HiRes 120 participated in this study. Three different defective electrode arrays were simulated (six separate defective contacts, three pairs or two triplets). The participants received three take-home strategies and were asked to evaluate the sound quality in five predefined listening conditions. After 3 weeks, SPS were evaluated with monosyllabic words in quiet and in speech-shaped background noise. The participants rated the sound quality equal for all take-home strategies. SPS with background noise were equal for all conditions tested. However, SPS in quiet (85% phonemes correct on average with the full array) decreased significantly with increasing spanning distance, with a 3% decrease for each spanned contact.

  17. Model-based evaluation of the short-circuited tripolar cuff configuration.

    Science.gov (United States)

    Andreasen, Lotte N S; Struijk, Johannes J

    2006-05-01

    Recordings of neural information for use as feedback in functional electrical stimulation are often contaminated with interfering signals from muscles and from stimulus pulses. The cuff electrode used for the neural recording can be optimized to improve the S/I ratio. In this work, we evaluate a model of both the nerve signal and the interfering signals recorded by a cuff, and subsequently use this model to study the signal to interference ratio of different cuff designs and to evaluate a recently introduced short-circuited tripolar cuff configuration. The results of the model showed good agreement with results from measurements in rabbits and confirmed the superior performance of the short-circuited tripolar configuration as compared with the traditionally used tripolar configuration.

  18. Contact Resistance Reduction of ZnO Thin Film Transistors (TFTs) with Saw-Shaped Electrode

    KAUST Repository

    Park, Woojin

    2018-05-15

    We report a saw-shaped electrode architecture ZnO thin film transistor (TFT) for effectively increase channel width. Such a saw-shaped electrode has ~2 times longer contact line at the contact metal/ZnO channel junction. We experimentally observed an enhancement in the output drive current by 50% and reduction in the contact resistance by over 50%, when compared to a typical shaped electrode ZnO TFT consuming the same chip area. This performance enhancement is attributed to extension of channel width. This technique can contribute to device performance enhancement and especially reduction in the contact resistance which is a serious challenge.

  19. New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes.

    Science.gov (United States)

    Vanamo, Ulriika; Hupa, Elisa; Yrjänä, Ville; Bobacka, Johan

    2016-04-19

    A novel approach to signal transduction concerning solid-contact ion-selective electrodes (SC-ISE) with a conducting polymer (CP) as the solid contact is investigated. The method presented here is based on constant potential coulometry, where the potential of the SC-ISE vs the reference electrode is kept constant using a potentiostat. The change in the potential at the interface between the ion-selective membrane (ISM) and the sample solution, due to the change in the activity of the primary ion, is compensated with a corresponding but opposite change in the potential of the CP solid contact. This enforced change in the potential of the solid contact results in a transient reducing/oxidizing current flow through the SC-ISE. By measuring and integrating the current needed to transfer the CP to a new state of equilibrium, the total cumulated charge that is linearly proportional to the change of the logarithm of the primary ion activity is obtained. In this work, different thicknesses of poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrenesulfonate) (PSS) were used as solid contact. Also, coated wire electrodes (CWEs) were included in the study to show the general validity of the new approach. The ISM employed was selective for K(+) ions, and the selectivity of the membrane under implementation of the presented transduction mechanism was confirmed by measurements performed with a constant background concentration of Na(+) ions. A unique feature of this signal readout principle is that it allows amplification of the analytical signal by increasing the capacitance (film thickness) of the solid contact of the SC-ISE.

  20. Robust, highly customizable, and economical multi-channel electrode for chronic multi-unit recording in behaving animals.

    Science.gov (United States)

    Tateyama, Yukina; Oyama, Kei; Shiraishi, Masaru; Iijima, Toshio; Tsutsui, Ken-Ichiro

    2017-12-01

    Multi-unit recording has been one of the most widely used techniques to investigate the correlation between multiple neuronal activities and behavior. However, a common problem of currently used multi-channel electrodes is their physical weakness. In this study, we developed a novel multi-channel electrode with sufficient physical strength to penetrate a thickened dura mater. This electrode consists of low-cost materials and is easily fabricated, and it enables recording without removing dura mater, thereby reducing the risk of inflammation, infection, or brain herniation. The low-cost multi-channel electrode developed in this study would be a useful tool for chronic recording in behaving animals. Copyright © 2017. Published by Elsevier B.V.

  1. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    Science.gov (United States)

    Jeong, Du Won; Jung, Jongjin; Kim, Gook Hwa; Yang, Cheol-Soo; Kim, Ju Jin; Jung, Sang Don; Lee, Jeong-O.

    2015-08-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV-ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions.

  2. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    International Nuclear Information System (INIS)

    Jeong, Du Won; Jin Kim, Ju; Jung, Jongjin; Yang, Cheol-Soo; Lee, Jeong-O; Hwa Kim, Gook; Don Jung, Sang

    2015-01-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV–ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions. (paper)

  3. Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

    Science.gov (United States)

    Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D

    2011-10-01

    To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.

  4. Speci﬿c contact resistance of phase change materials to metal electrode

    NARCIS (Netherlands)

    Roy, Deepu; in 't Zandt, Micha A.A.; Wolters, Robertus A.M.

    2010-01-01

    For phase change random access memory (PCRAM) cells, it is important to know the contact resistance of phase change materials (PCMs) to metal electrodes at the contacts. In this letter, we report the systematic determination of the speci﬿c contact resistance (Ͽc ) of doped Sb2Te and Ge2Sb2Te5 to TiW

  5. All-Solid-State Sodium-Selective Electrode with a Solid Contact of Chitosan/Prussian Blue Nanocomposite

    Directory of Open Access Journals (Sweden)

    Tanushree Ghosh

    2017-11-01

    Full Text Available Conventional ion-selective electrodes with a liquid junction have the disadvantage of potential drift. All-solid-state ion-selective electrodes with solid contact in between the metal electrode and the ion-selective membrane offer high capacitance or conductance to enhance potential stability. Solution-casted chitosan/Prussian blue nanocomposite (ChPBN was employed as the solid contact layer for an all-solid-state sodium ion-selective electrode in a potentiometric sodium ion sensor. Morphological and chemical analyses confirmed that the ChPBN is a macroporous network of chitosan that contains abundant Prussian blue nanoparticles. Situated between a screen-printed carbon electrode and a sodium-ionophore-filled polyvinylchloride ion-selective membrane, the ChPBN layer exhibited high redox capacitance and fast charge transfer capability, which significantly enhanced the performance of the sodium ion-selective electrode. A good Nernstian response with a slope of 52.4 mV/decade in the linear range from 10−4–1 M of NaCl was observed. The stability of the electrical potential of the new solid contact was tested by chronopotentiometry, and the capacitance of the electrode was 154 ± 4 µF. The response stability in terms of potential drift was excellent (1.3 µV/h for 20 h of continuous measurement. The ChPBN proved to be an efficient solid contact to enhance the potential stability of the all-solid-state ion-selective electrode.

  6. Single-molecule conductance with nitrile and amino contacts with Ag or Cu electrodes

    International Nuclear Information System (INIS)

    Li, Dong-Fang; Mao, Jin-Chuan; Chen, De-Li; Chen, Fang; Ze-Wen, Hong; Zhou, Xiao-Yi; Wang, Ya-Hao; Zhou, Xiao-Shun; Niu, Zhen-Jiang; Maisonhaute, Emmanuel

    2015-01-01

    The single-molecule conductance of 1,4-dicyanobenzene (DCB), 1,4-benzenediamine (BDA) and 4,4'-biphenyldicarbonitrile (BPDC) with Ag and/or Cu electrodes is measured by electrochemical jump-to-contact STM-break junction. All single-molecule junctions present three sets of conductance values revealing different contact geometries. We observe that the single-molecule conductance of Ag-BDA-Ag junction is larger that of Ag-DCB-Ag junction, and DCB with Ag contacts are more conductive than that with Cu ones. This is related to a different electronic coupling between the molecules and the electrodes. Tunneling decay constants of 1.70 and 1.68 per phenyl group were found for Ag and Cu electrodes, respectively. The present study therefore shows that nitrile and amino groups can also be used as effective anchors for other metals than gold

  7. Arthroscopic rotator cuff repair in elite rugby players.

    Science.gov (United States)

    Tambe, Amol; Badge, Ravi; Funk, Lennard

    2009-01-01

    Rugby is an increasingly popular collision sport. A wide spectrum of injuries can be sustained during training and match play. Rotator cuff injury is uncommon in contact sports and there is little published literature on the treatment of rotator cuff tears in rugby players. We therefore reviewed the results and functional outcomes of arthroscopic rotator cuff repair in elite rugby players. Eleven professional rugby players underwent arthroscopic rotator cuff repair at our hospital over a 2-year period. We collected data on these patients from the operative records. The patients were recalled for outcome scoring and ultrasound scans. There were seven rugby league players and four rugby union players, including six internationals. Their mean age was 25.7 years. All had had a traumatic episode during match play and could not return to the game after the injury. The mean time to surgery was 5 weeks. The mean width of the cuff tear was 1.8 cm. All were full- thickness cuff tears. Associated injuries included two Bankart lesions, one bony Bankart lesion, one posterior labral tear, and two 360 degrees labral tears. The biceps was involved in three cases. Two were debrided and a tenodesis was performed in one. Repair was with suture anchors. Following surgery, all patients underwent a supervised accelerated rehabilitation programme. The final follow-up was at 18 months (range: 6-31 months) post surgery. The Constant scores improved from 44 preoperatively to 99 at the last follow-up. The mean score at 3 months was 95. The Oxford shoulder score improved from 34 to 12, with the mean third month score being 18. The mean time taken to return to full match play at the preinjury level was 4.8 months. There were no complications in any of the patients and postoperative scans in nine patients confirmed that the repairs had healed. We conclude that full-thickness rotator cuff tears in the contact athlete can be addressed successfully by arthroscopic repair, with a rapid return to

  8. Fuel cell electrode interconnect contact material encapsulation and method

    Science.gov (United States)

    Derose, Anthony J.; Haltiner, Jr., Karl J.; Gudyka, Russell A.; Bonadies, Joseph V.; Silvis, Thomas W.

    2016-05-31

    A fuel cell stack includes a plurality of fuel cell cassettes each including a fuel cell with an anode and a cathode. Each fuel cell cassette also includes an electrode interconnect adjacent to the anode or the cathode for providing electrical communication between an adjacent fuel cell cassette and the anode or the cathode. The interconnect includes a plurality of electrode interconnect protrusions defining a flow passage along the anode or the cathode for communicating oxidant or fuel to the anode or the cathode. An electrically conductive material is disposed between at least one of the electrode interconnect protrusions and the anode or the cathode in order to provide a stable electrical contact between the electrode interconnect and the anode or cathode. An encapsulating arrangement segregates the electrically conductive material from the flow passage thereby, preventing volatilization of the electrically conductive material in use of the fuel cell stack.

  9. All-solid-state potassium-selective electrode using graphene as the solid contact

    DEFF Research Database (Denmark)

    Li, Fenghua; Ye, Junjin; Zhou, Min

    2012-01-01

    Graphene sheets are used for the first time to fabricate a new type of solid-contact ion-selective electrode (SC-ISE) as the intermediate layer between an ionophore-doped solvent polymeric membrane and a glassy carbon electrode. The new transducing layer was characterized by transmission electron...

  10. Correction of electrode modelling errors in multi-frequency EIT imaging.

    Science.gov (United States)

    Jehl, Markus; Holder, David

    2016-06-01

    The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-linear multi-frequency EIT applications. To address this issue, we augmented the conductivity Jacobian matrix with a Jacobian matrix with respect to electrode movement. Using this new algorithm, simulated ischaemic and haemorrhagic strokes in a realistic head model were reconstructed for varying degrees of electrode position errors. The simultaneous recovery of conductivity spectra and electrode positions removed most artefacts caused by inaccurately modelled electrodes. Reconstructions were stable for electrode position errors of up to 1.5 mm standard deviation along both surface dimensions. We conclude that this method can be used for electrode model correction in multi-frequency EIT.

  11. The optimum tension for bridging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study.

    Science.gov (United States)

    Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han

    2015-09-01

    Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N. © 2015 The Author(s).

  12. Multi-component intermetallic electrodes for lithium batteries

    Science.gov (United States)

    Thackeray, Michael M; Trahey, Lynn; Vaughey, John T

    2015-03-10

    Multi-component intermetallic negative electrodes prepared by electrochemical deposition for non-aqueous lithium cells and batteries are disclosed. More specifically, the invention relates to composite intermetallic electrodes comprising two or more compounds containing metallic or metaloid elements, at least one element of which can react with lithium to form binary, ternary, quaternary or higher order compounds, these compounds being in combination with one or more other metals that are essentially inactive toward lithium and act predominantly, but not necessarily exclusively, to the electronic conductivity of, and as current collection agent for, the electrode. The invention relates more specifically to negative electrode materials that provide an operating potential between 0.05 and 2.0 V vs. metallic lithium.

  13. An in vitro comparison of tracheostomy tube cuffs

    Directory of Open Access Journals (Sweden)

    Maguire S

    2015-04-01

    Full Text Available Seamus Maguire,1 Frances Haury,2 Korinne Jew2 1Research and Development, Covidien Respiratory and Monitoring Solutions, Athlone, Ireland; 2Medical Affairs, Covidien Respiratory and Monitoring Solutions, Boulder, CO, USA Introduction: The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT] with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force.Methods: Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O, instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site.Results: The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05. The taper

  14. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  15. Solving conformal contacts using multi-Hertzian techniques

    Science.gov (United States)

    Pascal, Jean-Pierre; Soua, Brahim

    2016-06-01

    Recently, publications aiming at wheel-rail contact surveys let readers think that multi-Hertzian methods present severe drawbacks with respect to 'virtual penetration' methods. These surveys criticise multi-Hertzian solutions mainly because presenting 'larger contacts overlaps' and 'frequent secondary contacts near the border of the first contact', both obvious geometric possibilities of which the practical occurrence and eventual inconvenience would remain purely theoretical unless established over definite methods demonstrating poor practical results. Recent surveys all quote Piotrowski-Chollet 2005 survey of wheel-rail contact models that attempted to illustrate defective multi-Hertzian techniques by concentrating on the method initiated by Sauvage in the 1990s and further developed by Pascal. The 2005 paper not only gives no evidence of practical inconveniences of Sauvage's method but also confuses static geometric contact overlaps with the dynamical overlapping of forces. In reality it mixes Sauvage method up with a quite different technique. Thus a clarification is now necessary by reminding what the proper Sauvage technique really is and by showing some of its practical successful applications. The present paper, focusing on determination of normal contact forces in conformal situations, intends to explain clearly the advantages of the unequivocal localisation of secondary ellipses in that multi-Hertzian method which has been developed in INRETS VOCO codes in the 1990s and successfully used by SNCF and ALSTOM in the INRETS-SNCF code, VOCODYM, and later in Pascal's online calculation of railway elastic contacts code. It proved its effectiveness for studying freight wagons derailments as well as rail wear and head-check, unrounded wheels wear, high-speed lines' deformations or TGV comfort. While simulating American ACELA trainsets' behaviour on the US North-East Corridor tracks, prior to actual tests, as part of the commercial contract. It has been also a

  16. Multi-Electrode Impedance Method for Detection of Regional Ventilation

    International Nuclear Information System (INIS)

    Furuya, Norio; Sakamoto, Katsuyuki

    2013-01-01

    By means of computer simulation and experiment, we investigated the feasibility of simultaneously measuring the transfer impedance changes in the right apex, left apex, right base and left base of the lungs using the multi-electrode impedance method. To obtain the transfer impedance in each region, while suppressing the effects of other regions, changing the amplitude and polarity of the applied current must localize the high sensitivity areas in the interest region. Twelve current and eight voltage electrodes were equidistantly arranged on the anterior and posterior chest walls. The amplitudes and polarities of the currents that were simultaneously applied to the current electrodes, and which provided the appropriate sensitivity distribution, were theoretically obtained. The effects of the localized sensitivity distribution were verified by comparing the simulation results of the investigated method with the results of the conventional four-electrode method. From the results of the computer simulation, we developed a multi-electrode impedance pneumography and applied it to healthy adult volunteers who were both in sitting position and in left decubitus. We found that the measurement results were physiologically reasonable.

  17. Carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool

    International Nuclear Information System (INIS)

    Cai, Yu; Sha, Shuang

    2016-01-01

    This paper proposes a new carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool used in a cylindrical borehole environment during oil-based mud drilling processes. The new tool is an orthogonal frequency division multiplexing access-based contactless multi-measurand detection tool. The tool can measure formation resistivity in different azimuthal angles and elevational depths. It can measure many more measurands simultaneously in a specified bandwidth than the legacy frequency division multiplexing multi-measurand tool without a channel-select filter while avoiding inter-carrier interference. The paper also shows that formation resistivity is not sensitive to frequency in certain frequency bands. The average resistivity collected from N subcarriers can increase the measurement of the signal-to-noise ratio (SNR) by N times given no amplitude clipping in the current-injection electrode. If the clipping limit is taken into account, with the phase rotation of each single carrier, the amplitude peak-to-average ratio can be reduced by 3 times, and the SNR can achieve a 9/ N times gain over the single-carrier system. The carrier-interleaving technique is also introduced to counter the carrier frequency offset (CFO) effect, where the CFO will cause inter-pad interference. A qualitative analysis and simulations demonstrate that block-interleaving performs better than tone-interleaving when coping with a large CFO. The theoretical analysis also suggests that increasing the subcarrier number can increase the measurement speed or enhance elevational resolution without sacrificing receiver performance. The complex orthogonal multi-pad multi-carrier resistivity logging tool, in which all subcarriers are complex signals, can provide a larger available subcarrier pool than other types of transceivers. (paper)

  18. Preparation of electrodes on cfrp composites with low contact resistance comprising laser-based surface pre-treatment

    KAUST Repository

    Almuhammadi, Khaled Hamdan

    2016-12-29

    Various examples are provided related to the preparation of electrodes on carbon fiber reinforced polymer (CFRP) composites with low contact resistance. Laser-based surface preparation can be used for bonding to CFRP composites. In one example, a method includes preparing a pretreated target area on a CFRP composite surface using laser pulsed irradiation and bonding an electrode to exposed fibers in the pretreated target area. The surface preparation can allow the electrode to have a low contact resistance with the CFRP composite.

  19. Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics

    Directory of Open Access Journals (Sweden)

    Emil H. Rijnbeek

    2018-05-01

    Full Text Available In this paper various types of electrodes for stimulation and recording activity of peripheral nerves for the control of neuroprosthetic limbs are reviewed. First, an overview of interface devices for (feedback- controlled movement of a prosthetic device is given, after which the focus is on peripheral nervous system (PNS electrodes. Important electrode properties, i.e., longevity and spatial resolution, are defined based upon the usability for neuroprostheses. The cuff electrode, longitudinal intrafascicular electrodes (LIFE, transverse intrafascicular multichannel electrode (TIME, Utah slanted electrode array (USEA, and the regenerative electrode are discussed and assessed on their longevity and spatial resolution. The cuff electrode seems to be a promising electrode for the control of neuroprostheses in the near future, because it shows the best longevity and good spatial resolution and it has been used on human subjects in multiple studies. The other electrodes may be promising in the future, but further research on their longevity and spatial resolution is needed. A more quantitatively uniform study protocol used for all electrodes would allow for a proper comparison of recording and stimulation performance. For example, the discussed electrodes could be compared in a large in vivo study, using one uniform comparison protocol.

  20. Charge-carrier selective electrodes for organic bulk heterojunction solar cell by contact-printed siloxane oligomers

    International Nuclear Information System (INIS)

    Hwang, Hyun-Sik; Khang, Dahl-Young

    2015-01-01

    ‘Smart’ (or selective) electrode for charge carriers, both electrons and holes, in organic bulk-heterojunction (BHJ) solar cells using insertion layers made of hydrophobically-recovered and contact-printed siloxane oligomers between electrodes and active material has been demonstrated. The siloxane oligomer insertion layer has been formed at a given interface simply by conformally-contacting a cured slab of polydimethylsiloxane stamp for less than 100 s. All the devices, either siloxane oligomer printed at one interface only or printed at both interfaces, showed efficiency enhancement when compared to non-printed ones. The possible mechanism that is responsible for the observed efficiency enhancement has been discussed based on the point of optimum symmetry and photocurrent analysis. Besides its simplicity and large-area applicability, the demonstrated contact-printing technique does not involve any vacuum or wet processing steps and thus can be very useful for the roll-based, continuous production scheme for organic BHJ solar cells. - Highlights: • Carrier-selective insertion layer in organic bulk heterojunction solar cells • Simple contact-printing of siloxane oligomers improves cell efficiency. • Printed siloxane layer reduces carrier recombination at electrode surfaces. • Siloxane insertion layer works equally well at both electrode surfaces. • Patterned PDMS stamp shortens the printing time within 100 s

  1. Evaluation of contact resistance between carbon fiber/epoxy composite laminate and printed silver electrode for damage monitoring

    International Nuclear Information System (INIS)

    Jeon, Eun Beom; Kim, Hak Sung; Takahashi, Kosuke

    2014-01-01

    An addressable conducting network (ACN) makes it possible to monitor the condition of a structure using the electrical resistance between electrodes on the surface of a carbon fiber reinforced plastics (CFRP) structure. To improve the damage detection reliability of the ACN, the contact resistances between the electrodes and CFRP laminates needs to be minimized. In this study, silver nanoparticle electrodes were fabricated via printed electronics techniques on a CFRP composite. The contact resistance between the silver electrodes and CFRP were measured with respect to various fabrication conditions such as the sintering temperature of the silver nano-ink and the surface roughness of the CFRP laminates. The interfaces between the silver electrode and carbon fibers were observed using a scanning electron microscope (SEM). Based on this study, it was found that the lowest contact resistance of 0.3664Ω could be achieved when the sintering temperature of the silver nano-ink and surface roughness were 120 degree C and 0.230 a, respectively.

  2. A Respiratory Marker Derived From Left Vagus Nerve Signals Recorded With Implantable Cuff Electrodes.

    Science.gov (United States)

    Sevcencu, Cristian; Nielsen, Thomas N; Kjaergaard, Benedict; Struijk, Johannes J

    2018-04-01

    Left vagus nerve (LVN) stimulation (LVNS) has been tested for lowering the blood pressure (BP) in patients with resistant hypertension (RH). Whereas, closed-loop LVNS (CL-LVNS) driven by a BP marker may be superior to open-loop LVNS, there are situations (e.g., exercising) when hypertension is normal. Therefore, an ideal anti-RH CL-LVNS system requires a variable to avoid stimulation in such conditions, for example, a respiratory marker ideally extracted from the LVN. As the LVN conducts respiratory signals, this study aimed to investigate if such signals can be recorded using implantable means and if a marker to monitor respiration could be derived from such recordings. The experiments were performed in 14 anesthetized pigs. Five pigs were subjected to changes of the respiratory frequency and nine to changes of the respiratory volume. The LVN electroneurogram (VENG) was recorded using two cuff electrodes and the respiratory cycles (RC) using a pressure transducer. To separate the afferent and efferent VENGs, vagotomy was performed between the cuffs in the first group of pigs. The VENG was squared to derive respiration-related neural profiles (RnPs) and their correlation with the RCs was investigated in regard to timing and magnitude parameters derived from the two waveforms. The RnPs were morphologically similar with the RCs and the average RnPs represented accurate copies of the average RCs. Consequently, the lung inflation/deflation RC and RnP components had the same duration, the respiratory frequency changes affected in the same way both waveforms and the RnP amplitude increased linearly with the lung inflation in all tested pigs (R 2 values between 0.85 and 0.99). The RnPs comprise information regarding the timing and magnitude of the respiratory parameters. As those LVN profiles were derived using implantable means, this study indicates that the RnPs could serve as respiratory markers in implantable systems. © 2017 International Neuromodulation Society.

  3. Advanced Rotator Cuff Tear Score (ARoCuS): a multi-scaled tool for the classification and description of rotator cuff tears.

    Science.gov (United States)

    Walter, S G; Stadler, T; Thomas, T S; Thomas, W

    2018-03-02

    To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p tears in a standardized and reproducible manner.

  4. The effect of electrode contact resistance and capacitive coupling on Complex Resistivity measurements

    DEFF Research Database (Denmark)

    Ingeman-Nielsen, Thomas

    2006-01-01

    The effect of electrode contact resistance and capacitive coupling on complex resistivity (CR) measurements is studied in this paper. An equivalent circuit model for the receiver is developed to describe the effects. The model shows that CR measurements are severely affected even at relatively lo...... with the contact resistance artificially increased by resistors. The results emphasize the importance of keeping contact resistance low in CR measurements....

  5. Artificial control of muscle by endoneural multi electrode stimulation and sensing

    NARCIS (Netherlands)

    Rutten, Wim; Bouwman, R.L.M.

    1991-01-01

    Artificial electrical stimulation of motor nerves for muscle control can be made selective by using intrafascicular micro electrode arrays which contact many individual or small groups of nerve fibres. If at the same time te electrode arrays could record afferent information from the stimulated

  6. Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model

    Science.gov (United States)

    Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.

    2014-01-01

    Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P repair with 2-mm fiber tape alone (P repair with looped peripheral sutures compared with a suture bridge (P repair technique, peripheral No. 2 nonabsorbable looped sutures significantly decreased the volume, height, and width of dog ear deformities, better restoring the anatomic footprint of the rotator cuff. Clinical

  7. Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode

    Directory of Open Access Journals (Sweden)

    Aysenur Birinci

    2016-07-01

    Full Text Available A new solid contact copper selective electrode with a poly (vinyl chloride (PVC membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS.

  8. Rotator cuff exercises

    Science.gov (United States)

    ... 25560729 . Read More Frozen shoulder Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT scan Shoulder MRI scan Shoulder pain Patient Instructions Rotator cuff - self-care Shoulder surgery - discharge Using your ...

  9. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects

    Directory of Open Access Journals (Sweden)

    Maira Soliani Del Negro

    2014-12-01

    Full Text Available Introduction: The inflation pressure of the endotracheal tube cuff can cause ischemia of the tracheal mucosa at high pressures; thus, it can cause important tracheal morbidity and tracheal microaspiration of the oropharyngeal secretion, or it can even cause pneumonia associated with mechanical ventilation if the pressure of the cuff is insufficient. Objective: In order to investigate the effectiveness of the RUSCH® 7.5 mm endotracheal tube cuff, this study was designed to investigate the physical and mechanical aspects of the cuff in contact with the trachea. Methods: For this end, we developed an in vitro experimental model to assess the flow of dye (methylene blue by the inflated cuff on the wall of the artificial material. We also designed an in vivo study with 12 Large White pigs under endotracheal intubation. We instilled the same dye in the oral cavity of the animals, and we analyzed the presence or not of leakage in the trachea after the region of the cuff after their deaths (animal sacrifice. All cuffs were inflated at the pressure of 30 cmH2O. Results: We observed the passage of fluids through the cuff in all in vitro and in vivo experimental models. Conclusion: We conclude that, as well as several other cuff models in the literature, the RUSCH® 7.5 mm tube cuffs are also not able to completely seal the trachea and thus prevent aspiration of oropharyngeal secretions. Other prevention measures should be taken.

  10. Multi-electrode double layer capacitor having single electrolyte seal and aluminum-impregnated carbon cloth electrodes

    Science.gov (United States)

    Farahmandi, C. Joseph; Dispennette, John M.; Blank, Edward; Kolb, Alan C.

    1999-01-19

    A single cell, multi-electrode high performance double layer capacitor includes first and second flat stacks of electrodes adapted to be housed in a closeable two-part capacitor case which includes only a single electrolyte seal. Each electrode stack has a plurality of electrodes connected in parallel, with the electrodes of one stack being interleaved with the electrodes of the other stack to form an interleaved stack, and with the electrodes of each stack being electrically connected to respective capacitor terminals. A porous separator sleeve is inserted over the electrodes of one stack before interleaving to prevent electrical shorts between the electrodes. The electrodes are made by folding a compressible, low resistance, aluminum-impregnated carbon cloth, made from activated carbon fibers, around a current collector foil, with a tab of the foils of each electrode of each stack being connected in parallel and connected to the respective capacitor terminal. The height of the interleaved stack is somewhat greater than the inside height of the closed capacitor case, thereby requiring compression of the interleaved electrode stack when placed inside of the case, and thereby maintaining the interleaved electrode stack under modest constant pressure. The closed capacitor case is filled with an electrolytic solution and sealed. A preferred electrolytic solution is made by dissolving an appropriate salt into acetonitrile (CH.sub.3 CN). In one embodiment, the two parts of the capacitor case are conductive and function as the capacitor terminals.

  11. What happens to patients when we do not repair their cuff tears? Five-year rotator cuff quality-of-life index outcomes following nonoperative treatment of patients with full-thickness rotator cuff tears.

    Science.gov (United States)

    Boorman, Richard S; More, Kristie D; Hollinshead, Robert M; Wiley, James P; Mohtadi, Nicholas G; Lo, Ian K Y; Brett, Kelly R

    2018-03-01

    The purpose of this study was to examine 5-year outcomes in a prospective cohort of patients previously enrolled in a nonoperative rotator cuff tear treatment program. Patients with chronic (>3 months), full-thickness rotator cuff tears (demonstrated on imaging) who were referred to 1 of 2 senior shoulder surgeons were enrolled in the study between October 2008 and September 2010. They participated in a comprehensive, nonoperative, home-based treatment program. After 3 months, the outcome in these patients was defined as "successful" or "failed." Patients in the successful group were essentially asymptomatic and did not require surgery. Patients in the failed group were symptomatic and consented to undergo surgical repair. All patients were followed up at 1 year, 2 years, and 5 or more years. At 5 or more years, all patients were contacted for follow-up; the response rate was 84%. Approximately 75% of patients remained successfully treated with nonoperative treatment at 5 years and reported a mean rotator cuff quality-of-life index score of 83 of 100 (SD, 16). Furthermore, between 2 and 5 years, only 3 patients who had previously been defined as having a successful outcome became more symptomatic and underwent surgical rotator cuff repair. Those in whom nonoperative treatment had failed and who underwent surgical repair had a mean rotator cuff quality-of-life index score of 89 (SD, 11) at 5-year follow-up. The operative and nonoperative groups at 5-year follow-up were not significantly different (P = .11). Nonoperative treatment is an effective and lasting option for many patients with a chronic, full-thickness rotator cuff tear. While some clinicians may argue that nonoperative treatment delays inevitable surgical repair, our study shows that patients can do very well over time. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Indirect Electrochemical Oxidation with Multi Carbon Electrodes for Restaurant Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    I Dewa Ketut Sastrawidana

    2018-01-01

    Full Text Available The removal of organic matter from the restaurant wastewater was investigated using the electrochemical oxida-tion method with multi carbon electrodes in a parallel construction. The degradation process was monitored by the measurement of COD concentration as a function of electrolysis time. The effectof operating parameter conditions on COD removal were investigated including initial pH, distance between electrodes, and the applied voltage difference.The results showed that the treatment of restaurant wastewater containing 2 g/L chloride ion using the electrochemical oxidation technique at the operation conditions characterized by: pH 5, distance between electrode of 10 cm and applied voltage of 12 V, enabled to obtained COD removal of 92.84% within 90 min electrolysis time. It is can be concluded that the indirect electrochemical oxidation method with multi carbon electrodes can be used effectivelyas an alternative technology for reducing COD and may be potentially applied for removal organic pollutants from wastewater at the industrial scale.

  13. Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1999-01-01

    A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequently used...... temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size....

  14. Tripolar-cuff deviation from ideal model: assessment by bioelectric field simulations and saline-bath experiments.

    Science.gov (United States)

    Triantis, Iasonas F; Demosthenous, Andreas

    2008-06-01

    Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar cuffs, in combination with appropriate amplifier configurations, such as the quasi-tripole (QT) and the true-tripole (TT). The operation of these amplifiers, is based on the theoretical property of the nerve cuff to produce a linear relationship of potential versus distance along its length, internally, when external potentials appear between its ends. Thus, in principle, electroneurogram (ENG) recordings from an ideal tripolar cuff would be free from electromyogram (EMG) interference generated by nearby muscles. However, in practice the cuff exhibits non-ideal behaviour leading to "cuff imbalance". The main focus of this paper is to investigate the causes of cuff imbalance, to demonstrate that it should be incorporated as a main parameter in the theoretical ENG-recording cuff electrode model. In addition to cuff asymmetry and tissue growth, the proximity of the interference source to the cuff is shown to result in cuff imbalance. The influence of proximity imbalance on the performance of the QT and TT amplifiers is also considered. Proximity imbalance is studied using bioelectric field simulations and saline-bath experiments. Variation is observed with both distance (40 mm and 70 mm was examined) and orientation (0-180 degrees), with the latter causing a more severe effect especially when the source dipole and the cuff are vertical to each other. The simulations and measurements are in close agreement. Tissue growth imbalance and asymmetry imbalance are also investigated in vitro. Finally, the signal-to-interference ratio (SIR; ENG/EMG) of the QT and TT amplifiers is examined in the presence of cuff imbalance. It is shown that proximity imbalance results in their SIR to peak only at certain cuff orientation values. This important finding offers an insight as to why in practice ENG recordings using these amplifiers have been widely

  15. Fabrication and characterization of a multidirectional-sensitive contact-enhanced inertial microswitch with a electrophoretic flexible composite fixed electrode

    International Nuclear Information System (INIS)

    Yang, Zhuoqing; Zhu, Bin; Chen, Wenguo; Ding, Guifu; Wang, Hong; Zhao, Xiaolin

    2012-01-01

    A multidirectional-sensitive inertial microswitch with a polymer–metal composite fixed electrode has been designed and fabricated based on surface micromachining in this work. The microswitch mainly consists of a suspended proof mass as a movable electrode and a T-shaped structure on the substrate with maple leaf-like top and cantilevers around the central cylinder as vertical and lateral fixed electrodes. It can sense the applied shock accelerations from any radial direction in the xoy plane and z-axis. The new vertical composite fixed electrode of the switch is completed by electroplating and electrophoretic deposition, which can realize a flexible contact between the electrodes and reduce the bounces and prolong the contact time. As a result, the stability and reliability of the inertial switch could be greatly improved. The fabricated microswitches have been tested and characterized by a standard dropping hammer system. It is shown that the threshold acceleration of the prototype is generally uniform in different sensitive directions in the xoy plane and z-axis, which is about 70 g. The contact time of the microswitch with the composite fixed electrode is ∼110 µs in the vertical direction, which is longer than that (∼65 µs) without a polymer. The test data are in agreement with dynamic finite-element simulation results. (paper)

  16. Artificial urinary sphincter revision for urethral atrophy: comparing single cuff downsizing and tandem cuff placement

    Directory of Open Access Journals (Sweden)

    Brian J. Linder

    Full Text Available ABSTRACT Objective To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS revision for urethral atrophy. Materials and Methods We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs. Results Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82% were tandem cuff placements, 12 (18% were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98, body-mass index (p=0.95, prior pelvic radiation exposure (p=0.73 and length of follow-up (p=0.12. Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94. Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94 or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77. Conclusions There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy.

  17. Instrumentasi Elektrokardiografi dengan Capacitive Contact Electrode pada Kursi

    Directory of Open Access Journals (Sweden)

    Monica Regina Emilia

    2017-01-01

    Full Text Available Elektrokardiograf secara konvensional menggunakan elektroda Ag-AgCl sebagai conductive contact dan kabel sebagai penghubung antara elektroda dengan elektrokardiograf. Metode yang digunakan bersifat direct sehingga elektroda melekat langsung pada kulit. Konfigurasi ini mengakibatkan ruang gerak pengguna menjadi terbatas dan dalam jangka panjang dapat menyebabkan iritasi pada kulit. Oleh karena itu, pada tugas akhir ini akan difokuskan pada perancangan Instrumentasi Elektrokardiografi secara indirect menggunakan capacitive electrode. Elektroda dibuat dengan menggunakan komponen IC dengan input impedansi tinggi sehingga sinyal jantung dapat direkam walau terhalang oleh pakaian sekalipun. Elektroda dibuat sejumlah 2 buah dan diletakkan pada sandaran kursi, sedangkan untuk ground digunakan PCB berukuran 30cmx30cm sebagai alas duduk. Ketiga sinyal ini kemudian dilewatkan pada rangkaian penguat instrumentasi, filter dan baseline restoration untuk menguatkan dan menghilangkan komponen sinyal yang tidak diperlukan. Dari pengujian yang telah dilakukan, sinyal QRS complex dapat terdeteksi dengan jelas. Kualitas sinyal yang dihasilkan sangat bergantung dari pakaian yang digunakan. Oleh karena itu capacitive electrode memiliki peluang yang besar untuk dijadikan sebagai elektroda alternatif yang bisa digunakan dalam jangka panjang.

  18. The influence of simulated rotator cuff tears on the risk for impingement in handbike and handrim wheelchair propulsion

    NARCIS (Netherlands)

    van Drongelen, S.; Schlussel, M.; Arnet, U.; Veeger, H.E.J.

    2013-01-01

    Background: Rotator cuff tears strongly affect the biomechanics of the shoulder joint in their role to regulate the joint contact force needed to prevent the joint from dislocation. The aim of this study was to investigate the influence of simulated progressed rotator cuff tears on the (in)stability

  19. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    Science.gov (United States)

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  20. A study of effects of electrode contacts on performance of organic-based light-emitting field-effect transistors

    Science.gov (United States)

    Kim, Dae-Kyu; Choi, Jong-Ho

    2018-02-01

    Herein is presented a comparative performance analysis of heterojunction organic-based light-emitting field-effect transistors (OLEFETs) with symmetric (Au only) and asymmetric (Au and LiF/Al) electrode contacts. The devices had a top source-drain contact with long-channel geometry and were produced by sequentially depositing p-type pentacene and n-type N,N‧-ditridecylperylene-3,4,9,10-tetracarboxylic diimide (P13) using a neutral cluster beam deposition apparatus. The spectroscopic, structural and morphological properties of the organic thin films were examined using photoluminescence (PL) spectroscopy, X-ray diffraction (XRD) method, laser scanning confocal and atomic force microscopy (LSCM, AFM). Based upon the growth of high-quality, well-packed crystalline thin films, the devices demonstrated ambipolar field-effect characteristics, stress-free operational stability, and light emission under ambient conditions. Various device parameters were derived from the fits of the observed characteristics. The hole mobilities were nearly equal irrespective of the electrode contacts, whereas the electron mobilities of the transistors with LiF/Al drain electrodes were higher due to the low injection barrier. For the OLEFETs with symmetric electrodes, electroluminescence (EL) occurred only in the vicinity of the hole-injecting electrode, whereas for the OLEFETs with asymmetric electrodes, the emission occurred in the vicinity of both hole- and electron-injecting electrodes. By tuning the carrier injection and transport through high- and low-work function metals, the hole-electron recombination sites could be controlled. The operating conduction and light emission mechanism are discussed with the aid of EL images obtained using a charge-coupled device (CCD) camera.

  1. Dynamic Multi-Rigid-Body Systems with Concurrent Distributed Contacts: Theory and Examples

    International Nuclear Information System (INIS)

    TRINKLE, JEFFREY C.; TZITZOURIS, J.A.; PANG, J.S.

    2001-01-01

    Consider a system of rigid bodies with multiple concurrent contacts. The multi-rigid-body contact problem is to predict the accelerations of the bodies and the normal friction loads acting at the contacts. This paper presents theoretical results for the multi-rigid-body contact problem under the assumptions that one or more contacts occur over locally planar, finite regions and that friction forces are consistent with the maximum work inequality. Existence and uniqueness results are presented for this problem under mild assumptions on the system inputs. In addition, the performance of two different time-stepping methods for integrating the dynamics are compared on two simple multi-body systems

  2. [Rotator cuff tear athropathy prevalence].

    Science.gov (United States)

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  3. Development of a new all solid contact Cs"+ ion selective electrode

    International Nuclear Information System (INIS)

    Ramanjaneyulu, P.S.; Abha Naveen Kumar; Sharma, M.K.

    2017-01-01

    Studies were carried out to develop all solid contact cesium ion selective electrode with 25,27-bis(1-octyloxy)calix[4]arene-crown-6 as an ionophore. Polyaniline (PANI), deposited on Pt electrode by electrochemical method, was used as a transducer. Three different types of electrodes were made with variation in thickness of PANI film and gold nanoparticles doped PANI as transducers. The best response was observed with ISE having Au nanoparticles doped PANI as a transducer. The optimised ISE gave Nernstian response in the range 10"-"7 to 10"-"2 M with the slope of 55.0 ± 0.6 mV/decade of Cs"+. The response of ISE for Cs"+ is fairly constant above the pH 4. The developed ISE was successfully employed to determine Cs"+ in simulated high level nuclear waste solutions and CsCl spiked tap water samples. (author)

  4. Determination of work function of graphene under a metal electrode and its role in contact resistance.

    Science.gov (United States)

    Song, Seung Min; Park, Jong Kyung; Sul, One Jae; Cho, Byung Jin

    2012-08-08

    Although the work function of graphene under a given metal electrode is critical information for the realization of high-performance graphene-based electronic devices, relatively little relevant research has been carried out to date. In this work, the work function values of graphene under various metals are accurately measured for the first time through a detailed analysis of the capacitance-voltage (C-V) characteristics of a metal-graphene-oxide-semiconductor (MGOS) capacitor structure. In contrast to the high work function of exposed graphene of 4.89-5.16 eV, the work function of graphene under a metal electrode varies depending on the metal species. With a Cr/Au or Ni contact, the work function of graphene is pinned to that of the contacted metal, whereas with a Pd or Au contact the work function assumes a value of ∼4.62 eV regardless of the work function of the contact metal. A study of the gate voltage dependence on the contact resistance shows that the latter case provides lower contact resistance.

  5. Low noise multi-channel biopotential wireless data acquisition system for dry electrodes

    Science.gov (United States)

    Pandian, P. S.; Whitchurch, Ashwin K.; Abraham, Jose K.; Bhusan Baskey, Himanshu; Radhakrishnan, J. K.; Varadan, Vijay K.; Padaki, V. C.; Bhasker Rao, K. U.; Harbaugh, R. E.

    2008-03-01

    The bioelectrical potentials generated within the human body are the result of electrochemical activity in the excitable cells of the nervous, muscular or glandular tissues. The ionic potentials are measured using biopotential electrodes which convert ionic potentials to electronic potentials. The commonly monitored biopotential signals are Electrocardiogram (ECG), Electroencephalogram (EEG) and Electromyogram (EMG). The electrodes used to monitor biopotential signals are Ag-AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gels used in biopotential recordings dry out when used for longer durations and add noise to the signals and also prolonged use of gels cause irritations and rashes to skin. Also noises such as motion artifact and baseline wander are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry electrodes are used, where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The major drawback associated with the dry electrodes is the high skin-electrode impedance in the low frequency range between 0.1-120 Hz, which makes it difficult to acquire clean and noise free biopotential signals. The paper presents the design and development of biopotential data acquisition and processing system to acquire biopotential signals from dry electrodes. The electrode-skin-electrode- impedance (ESEI) measurements was carried out for the dry electrodes by impedance spectroscopy. The biopotential signals are processed using an instrumentation amplifier with high CMRR and high input impedance achieved by boot strapping the input terminals. The signals are band limited by means of a second order Butterworth band pass filters to eliminate noise. The processed biopotential signals are digitized

  6. Rotator cuff - self-care

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000358.htm Rotator cuff - self-care To use the sharing features on ... and shoulder exercises may help ease your symptoms. Rotator Cuff Problems Common rotator cuff problems include: Tendinitis , which ...

  7. Investigation of Implantable Multi-Channel Electrode Array in Rat Cerebral Cortex Used for Recording

    Science.gov (United States)

    Taniguchi, Noriyuki; Fukayama, Osamu; Suzuki, Takafumi; Mabuchi, Kunihiko

    There have recently been many studies concerning the control of robot movements using neural signals recorded from the brain (usually called the Brain-Machine interface (BMI)). We fabricated implantable multi-electrode arrays to obtain neural signals from the rat cerebral cortex. As any multi-electrode array should have electrode alignment that minimizes invasion, it is necessary to customize the recording site. We designed three types of 22-channel multi-electrode arrays, i.e., 1) wide, 2) three-layered, and 3) separate. The first extensively covers the cerebral cortex. The second has a length of 2 mm, which can cover the area of the primary motor cortex. The third array has a separate structure, which corresponds to the position of the forelimb and hindlimb areas of the primary motor cortex. These arrays were implanted into the cerebral cortex of a rat. We estimated the walking speed from neural signals using our fabricated three-layered array to investigate its feasibility for BMI research. The neural signal of the rat and its walking speed were simultaneously recorded. The results revealed that evaluation using either the anterior electrode group or posterior group provided accurate estimates. However, two electrode groups around the center yielded poor estimates although it was possible to record neural signals.

  8. Contact engineering for efficient charge injection in organic transistors with low-cost metal electrodes

    Science.gov (United States)

    Panigrahi, D.; Kumar, S.; Dhar, A.

    2017-10-01

    Controlling charge injection at the metal-semiconductor interface is very crucial for organic electronic devices in general as it can significantly influence the overall device performance. Herein, we report a facile, yet efficient contact modification approach, to enhance the hole injection efficiency through the incorporation of a high vacuum deposited TPD [N,N'-Bis(3-methylphenyl)-N,N'-diphenylbenzidine] interlayer between the electrodes and the active semiconducting layer. The device performance parameters such as mobility and on/off ratio improved significantly after the inclusion of the TPD buffer layer, and more interestingly, the devices with cost effective Ag and Cu electrodes were able to exhibit a superior device performance than the typically used Au source-drain devices. We have also observed that this contact modification technique can be even more effective than commonly used metal oxide interface modifying layers. Our investigations demonstrate the efficacy of the TPD interlayer in effectively reducing the interfacial contact resistance through the modification of pentacene energy levels, which consequently results in the substantial improvement in the device performances.

  9. Cyclic voltammetric investigations of microstructured and platinum-covered glassy carbon electrodes in contact with a polymer electrolyte membrane

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, G G; Veziridis, Z; Staub, M [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Freimuth, H [Inst. fuer Mikrotechnik Mainz IMM, Mainz (Germany)

    1997-06-01

    Model gas diffusion electrodes were prepared by microstructuring glassy carbon surfaces with high aspect ratios and subsequent deposition of platinum. These electrodes were characterized by hydrogen under-potential deposition (H-upd) in contact with a polymer electrolyte membrane employing cyclic voltametry. H-upd was found on platinum areas not in direct contact to the solid electrolyte, as long as a continuous platinum-path existed. A carbon surface between platinum acts as barrier for H-upd. (author) 4 figs., 5 refs.

  10. Influence of Electrode Design and Contacting Layers on Performance of Electrolyte Supported SOFC/SOEC Single Cells

    Directory of Open Access Journals (Sweden)

    Mihails Kusnezoff

    2016-11-01

    Full Text Available The solid oxide cell is a basis for highly efficient and reversible electrochemical energy conversion. A single cell based on a planar electrolyte substrate as support (ESC is often utilized for SOFC/SOEC stack manufacturing and fulfills necessary requirements for application in small, medium and large scale fuel cell and electrolysis systems. Thickness of the electrolyte substrate, and its ionic conductivity limits the power density of the ESC. To improve the performance of this cell type in SOFC/SOEC mode, alternative fuel electrodes, on the basis of Ni/CGO as well as electrolytes with reduced thickness, have been applied. Furthermore, different interlayers on the air side have been tested to avoid the electrode delamination and to reduce the cell degradation in electrolysis mode. Finally, the influence of the contacting layer on cell performance, especially for cells with an ultrathin electrolyte and thin electrode layers, has been investigated. It has been found that Ni/CGO outperform traditional Ni/8YSZ electrodes and the introduction of a ScSZ interlayer substantially reduces the degradation rate of ESC in electrolysis mode. Furthermore, it was demonstrated that, for thin electrodes, the application of contacting layers with good conductivity and adhesion to current collectors improves performance significantly.

  11. Influence of Electrode Design and Contacting Layers on Performance of Electrolyte Supported SOFC/SOEC Single Cells.

    Science.gov (United States)

    Kusnezoff, Mihails; Trofimenko, Nikolai; Müller, Martin; Michaelis, Alexander

    2016-11-08

    The solid oxide cell is a basis for highly efficient and reversible electrochemical energy conversion. A single cell based on a planar electrolyte substrate as support (ESC) is often utilized for SOFC/SOEC stack manufacturing and fulfills necessary requirements for application in small, medium and large scale fuel cell and electrolysis systems. Thickness of the electrolyte substrate, and its ionic conductivity limits the power density of the ESC. To improve the performance of this cell type in SOFC/SOEC mode, alternative fuel electrodes, on the basis of Ni/CGO as well as electrolytes with reduced thickness, have been applied. Furthermore, different interlayers on the air side have been tested to avoid the electrode delamination and to reduce the cell degradation in electrolysis mode. Finally, the influence of the contacting layer on cell performance, especially for cells with an ultrathin electrolyte and thin electrode layers, has been investigated. It has been found that Ni/CGO outperform traditional Ni/8YSZ electrodes and the introduction of a ScSZ interlayer substantially reduces the degradation rate of ESC in electrolysis mode. Furthermore, it was demonstrated that, for thin electrodes, the application of contacting layers with good conductivity and adhesion to current collectors improves performance significantly.

  12. Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes.

    Science.gov (United States)

    Baumer, Timothy G; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S; Divine, George; Moutzouros, Vasilios; Bey, Michael J

    2017-06-01

    The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances

    International Nuclear Information System (INIS)

    Demidenko, Eugene

    2011-01-01

    An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expressed via elliptic integral (Pidcock et al 1995 Physiol. Meas. 16 77–90). The Dirichlet-to-Neumann map is derived for statistical estimation via nonlinear least squares. The solution is validated in phantom experiments and applied for breast contact impedance estimation in vivo. Statistical hypothesis testing is used to test whether the contact impedances are the same across electrodes or all equal zero. Our solution can be especially useful for a rapid real-time test for bad surface contact in clinical setting

  14. High-Speed Visualization of Evaporation Phenomena from Tungsten Based Electrode in Multi-Phase AC Arc

    Science.gov (United States)

    Tanaka, Manabu; Hashizume, Taro; Imatsuji, Tomoyuki; Nawata, Yushi; Watanabe, Takayuki

    2015-09-01

    A multi-phase AC arc has been developed for applications in various fields of engineering because it possesses unique advantages such as high energy efficiency. However, understanding of fundamental phenomena in the multi-phase AC arc is still insufficient for practical use. Purpose of this study is to investigate electrode erosion mechanism by high-speed visualization of the electrode metal vapor in the arc. Results indicated that the electrode mainly evaporated at anodic period, leading to the arc constriction. Moreover, evaporation of W electrode with 2wt% La2O3 at the anodic period was much higher than that with 2wt% ThO2. This can be explained by different properties of these oxide additives. Evaporation of the oxide additive resulted in the arc constriction, which accelerated the evaporation of W electrode. Therefore, addition of La2O3 with lower melting and boiling point than ThO2 lead to stronger arc constriction, resulting in severer evaporation of W electrode.

  15. Simultaneous Detection of Displacement, Rotation Angle, and Contact Pressure Using Sandpaper Molded Elastomer Based Triple Electrode Sensor.

    Science.gov (United States)

    Choi, Eunsuk; Sul, Onejae; Lee, Seung-Beck

    2017-09-06

    In this article, we report on a flexible sensor based on a sandpaper molded elastomer that simultaneously detects planar displacement, rotation angle, and vertical contact pressure. When displacement, rotation, and contact pressure are applied, the contact area between the translating top elastomer electrode and the stationary three bottom electrodes change characteristically depending on the movement, making it possible to distinguish between them. The sandpaper molded undulating surface of the elastomer reduces friction at the contact allowing the sensor not to affect the movement during measurement. The sensor showed a 0.25 mm −1 displacement sensitivity with a ±33 μm accuracy, a 0.027 degree −1 of rotation sensitivity with ~0.95 degree accuracy, and a 4.96 kP −1 of pressure sensitivity. For possible application to joint movement detection, we demonstrated that our sensor effectively detected the up-and-down motion of a human forefinger and the bending and straightening motion of a human arm.

  16. Contact Resistance Reduction of ZnO Thin Film Transistors (TFTs) with Saw-Shaped Electrode

    KAUST Repository

    Park, Woojin; Shaikh, Sohail F.; Min, Jungwook; Lee, Sang Kyung; Lee, Byoung Hun; Hussain, Muhammad Mustafa

    2018-01-01

    an enhancement in the output drive current by 50% and reduction in the contact resistance by over 50%, when compared to a typical shaped electrode ZnO TFT consuming the same chip area. This performance enhancement is attributed to extension of channel width

  17. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  18. Carbon paste electrode in a solid-contact minicavity

    International Nuclear Information System (INIS)

    Ferreira, Antonio Ap. Pupim; Ribeiro, Sidney Jose Lima; Fugivara, Cecilio Sadao; Caiut, Jose Mauricio Almeida; Sargentelli, Vagner; Benedetti, Assis Vicente

    2011-01-01

    This work describes the preparation of carbon paste electrode (EPC) in a solid-contact minicavity and its evaluation when containing carbon paste without and with SiO 2 (Eu 3+ 2%) and SiO 2 (Eu 3+ 2%)-lysine sub-micrometrics particles. For this study cyclic voltammetry and electrochemical impedance measurements were performed at pH 7.4 in 0.1 mol L -1 PBS containing Fe(CN) 6 -3 / -4 redox species. The impedance results were interpreted based on a charge-transfer reaction involving Fe(CN) 6 -3 / -4 species and/or oxygen at higher frequencies and, diffusion of the electroactive species and carbon paste characteristics at lower frequencies. EPC-minicavity is suitable for electroanalysis using modified carbon paste. (author)

  19. Rotator cuff tear: A detailed update

    Directory of Open Access Journals (Sweden)

    Vivek Pandey

    2015-01-01

    Full Text Available Rotator cuff tear has been a known entity for orthopaedic surgeons for more than two hundred years. Although the exact pathogenesis is controversial, a combination of intrinsic factors proposed by Codman and extrinsic factors theorized by Neer is likely responsible for most rotator cuff tears. Magnetic resonance imaging remains the gold standard for the diagnosis of rotator cuff tears, but the emergence of ultrasound has revolutionized the diagnostic capability. Even though mini-open rotator cuff repair is still commonly performed, and results are comparable to arthroscopic repair, all-arthroscopic repair of rotator cuff tear is now fast becoming a standard care for rotator cuff repair. Appropriate knowledge of pathology and healing pattern of cuff, strong and biological repair techniques, better suture anchors, and gradual rehabilitation of postcuff repair have led to good to excellent outcome after repair. As the healing of degenerative cuff tear remains unpredictable, the role of biological agents such as platelet-rich plasma and stem cells for postcuff repair augmentation is still under evaluation. The role of scaffolds in massive cuff tear is also being probed.

  20. Optogenetic Modulation and Multi-Electrode Analysis of Cerebellar Networks In Vivo

    Science.gov (United States)

    Kruse, Wolfgang; Krause, Martin; Aarse, Janna; Mark, Melanie D.; Manahan-Vaughan, Denise; Herlitze, Stefan

    2014-01-01

    The firing patterns of cerebellar Purkinje cells (PCs), as the sole output of the cerebellar cortex, determine and tune motor behavior. PC firing is modulated by various inputs from different brain regions and by cell-types including granule cells (GCs), climbing fibers and inhibitory interneurons. To understand how signal integration in PCs occurs and how subtle changes in the modulation of PC firing lead to adjustment of motor behaviors, it is important to precisely record PC firing in vivo and to control modulatory pathways in a spatio-temporal manner. Combining optogenetic and multi-electrode approaches, we established a new method to integrate light-guides into a multi-electrode system. With this method we are able to variably position the light-guide in defined regions relative to the recording electrode with micrometer precision. We show that PC firing can be precisely monitored and modulated by light-activation of channelrhodopsin-2 (ChR2) expressed in PCs, GCs and interneurons. Thus, this method is ideally suited to investigate the spatio/temporal modulation of PCs in anesthetized and in behaving mice. PMID:25144735

  1. Optogenetic modulation and multi-electrode analysis of cerebellar networks in vivo.

    Directory of Open Access Journals (Sweden)

    Wolfgang Kruse

    Full Text Available The firing patterns of cerebellar Purkinje cells (PCs, as the sole output of the cerebellar cortex, determine and tune motor behavior. PC firing is modulated by various inputs from different brain regions and by cell-types including granule cells (GCs, climbing fibers and inhibitory interneurons. To understand how signal integration in PCs occurs and how subtle changes in the modulation of PC firing lead to adjustment of motor behaviors, it is important to precisely record PC firing in vivo and to control modulatory pathways in a spatio-temporal manner. Combining optogenetic and multi-electrode approaches, we established a new method to integrate light-guides into a multi-electrode system. With this method we are able to variably position the light-guide in defined regions relative to the recording electrode with micrometer precision. We show that PC firing can be precisely monitored and modulated by light-activation of channelrhodopsin-2 (ChR2 expressed in PCs, GCs and interneurons. Thus, this method is ideally suited to investigate the spatio/temporal modulation of PCs in anesthetized and in behaving mice.

  2. Physical characterization of amorphous In-Ga-Zn-O thin-film transistors with direct-contact asymmetric graphene electrode

    Directory of Open Access Journals (Sweden)

    Jaewook Jeong

    2014-09-01

    Full Text Available High performance a-IGZO thin-film transistors (TFTs are fabricated using an asymmetric graphene drain electrode structure. A-IGZO TFTs (channel length = 3 μm were successfully demonstrated with a saturation field-effect mobility of 6.6 cm2/Vs without additional processes between the graphene and a-IGZO layer. The graphene/a-IGZO junction exhibits Schottky characteristics and the contact property is affected not only by the Schottky barrier but also by the parasitic resistance from the depletion region under the graphene electrode. Therefore, to utilize the graphene layer as S/D electrodes for a-IGZO TFTs, an asymmetric electrode is essential, which can be easily applied to the conventional pixel electrode structure.

  3. Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring.

    Science.gov (United States)

    Vasylieva, Natalia; Marinesco, Stéphane; Barbier, Daniel; Sabac, Andrei

    2015-10-15

    Simultaneous monitoring of glucose and lactate is an important challenge for understanding brain energetics in physiological or pathological states. We demonstrate here a versatile method based on a minimally invasive single implantation in the rat brain. A silicon/SU8-polymer multi-sensing needle-shaped biosensor, was fabricated and tested. The multi-electrode array design comprises three platinum planar microelectrodes with a surface area of 40 × 200 µm(2) and a spacing of 200 µm, which were micromachined on a single 3mm long micro-needle having a 100 × 50 µm(2) cross-section for reduced tissue damage during implantation. Platinum micro-electrodes were aligned at the bottom of micro-wells obtained by photolithography on a SU8 photoresist layer. After clean room processing, each micro-electrode was functionalized inside the micro-wells by means of a micro-dispensing device, either with glucose oxidase or with lactate oxidase, which were cross-linked on the platinum electrodes. The third electrode covered with Bovine Serum Albumin (BSA) was used for the control of non-specific currents. The thick SU8 photoresist layer has revealed excellent electrical insulation of the micro-electrodes and between interconnection lines, and ensured a precise localization and packaging of the sensing enzymes on platinum micro-electrodes. During in vitro calibration with concentrations of analytes in the mM range, the micro-wells patterned in the SU8 photoresist proved to be highly effective in eliminating cross-talk signals, caused by H2O2 diffusion from closely spaced micro-electrodes. Moreover, our biosensor was successfully assayed in the rat cortex for simultaneous monitoring of both glucose and lactate during insulin and glucose administration. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Braided Multi-Electrode Probes (BMEPs) for Neural Interfaces

    Science.gov (United States)

    Kim, Tae Gyo

    Although clinical use of invasive neural interfaces is very limited, due to safety and reliability concerns, the potential benefits of their use in brain machine interfaces (BMIs) seem promising and so they have been widely used in the research field. Microelectrodes as invasive neural interfaces are the core tool to record neural activities and their failure is a critical issue for BMI systems. Possible sources of this failure are neural tissue motions and their interactions with stiff electrode arrays or probes fixed to the skull. To overcome these tissue motion problems, we have developed novel braided multi-electrode probes (BMEPs). By interweaving ultra-fine wires into a tubular braid structure, we obtained a highly flexible multi-electrode probe. In this thesis we described BMEP designs and how to fabricate BMEPs, and explore experiments to show the advantages of BMEPs through a mechanical compliance comparison and a chronic immunohistological comparison with single 50microm nichrome wires used as a reference electrode type. Results from the mechanical compliance test showed that the bodies of BMEPs have 4 to 21 times higher compliance than the single 50microm wire and the tethers of BMEPs were 6 to 96 times higher compliance, depending on combinations of the wire size (9.6microm or 12.7microm), the wire numbers (12 or 24), and the length of tether (3, 5 or 10 mm). Results from the immunohistological comparison showed that both BMEPs and 50microm wires anchored to the skull caused stronger tissue reactions than unanchored BMEPs and 50microm wires, and 50microm wires caused stronger tissue reactions than BMEPs. In in-vivo tests with BMEPs, we succeeded in chronic recordings from the spinal cord of freely jumping frogs and in acute recordings from the spinal cord of decerebrate rats during air stepping which was evoked by mesencephalic locomotor region (MLR) stimulation. This technology may provide a stable and reliable neural interface to spinal cord

  5. Anchoring alpha-manganese oxide nanocrystallites on multi-walled carbon nanotubes as electrode materials for supercapacitor

    Science.gov (United States)

    Li, Li; Qin, Zong-Yi; Wang, Ling-Feng; Liu, Hong-Jin; Zhu, Mei-Fang

    2010-09-01

    The partial coverage of manganese oxide (MnO2) particles was achieved on the surfaces of multi-walled carbon nanotubes (MWCNTs) through a facile hydrothermal process. These particles were demonstrated to be alpha-manganese dioxide (α-MnO2) nanocrystallites, and exhibited the appearance of the whisker-shaped crystals with the length of 80-100 nm. In such a configuration, the uncovered CNTs in the nanocomposite acted as a good conductive pathway and the whisker-shaped MnO2 nanocrystallites efficiently increased the contact of the electrolyte with the active materials. Thus, the highest specific capacitance of 550 F g-1 was achieved using the resulting nanocomposites as the supercapacitor electrode. In addition, the enhancement of the capacity retention was observed, with the nanocomposite losing only 10% of the maximum capacity after 1,500 cycles.

  6. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implants.

    Science.gov (United States)

    Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y

    2016-07-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs.

  7. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implantsa)

    Science.gov (United States)

    Todd, Ann E.; Goupell, Matthew J.; Litovsky, Ruth Y.

    2016-01-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs. PMID:27475132

  8. Delaminated rotator cuff tear: extension of delamination and cuff integrity after arthroscopic rotator cuff repair.

    Science.gov (United States)

    Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John

    2015-05-01

    The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Electrical stimulus artifact cancellation and neural spike detection on large multi-electrode arrays.

    Science.gov (United States)

    Mena, Gonzalo E; Grosberg, Lauren E; Madugula, Sasidhar; Hottowy, Paweł; Litke, Alan; Cunningham, John; Chichilnisky, E J; Paninski, Liam

    2017-11-01

    Simultaneous electrical stimulation and recording using multi-electrode arrays can provide a valuable technique for studying circuit connectivity and engineering neural interfaces. However, interpreting these measurements is challenging because the spike sorting process (identifying and segregating action potentials arising from different neurons) is greatly complicated by electrical stimulation artifacts across the array, which can exhibit complex and nonlinear waveforms, and overlap temporarily with evoked spikes. Here we develop a scalable algorithm based on a structured Gaussian Process model to estimate the artifact and identify evoked spikes. The effectiveness of our methods is demonstrated in both real and simulated 512-electrode recordings in the peripheral primate retina with single-electrode and several types of multi-electrode stimulation. We establish small error rates in the identification of evoked spikes, with a computational complexity that is compatible with real-time data analysis. This technology may be helpful in the design of future high-resolution sensory prostheses based on tailored stimulation (e.g., retinal prostheses), and for closed-loop neural stimulation at a much larger scale than currently possible.

  10. A case of laparoscopy-assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Tomoatsu Jimi

    Full Text Available Introduction: Vaginal cuff dehiscence after hysterectomy is a rare complication and occurs in less than 1% of patients. It can present with serious complications, such as bowel evisceration and peritonitis. Presentation of case: A 51-year-old multigravida Korean woman underwent total laparoscopic hysterectomy for leiomyoma. Six months later, she reported lower abdominal pain and vaginal bleeding. Physical examination revealed rebound tenderness in the lower abdomen, and pelvic examination showed a small amount of vaginal bleeding with an evisceration of the small intestine through the vagina that exhibited healthy peristalsis. The eviscerated bowel, which seemed to be a part of the ileum, was carefully manually reduced transvaginally into the abdominal cavity. Laparoscopic observation revealed adhesions between the omentum, small intestine, and the peritoneum. Specifically, the small intestine was adhered around the vaginal cuff. An abdominal abscess was found in the left lower abdominal cavity. An adhesiotomy was performed and the abdominal abscess was removed and irrigated. Complete separation of the anterior and posterior vaginal cuff edges was obtained. The vaginal cuff was closed with interrupted 0-polydioxanone absorbable sutures without bowel injury. A 6-month follow-up examination revealed complete healing of the vaginal cuff. Discussion: In this case, we were able to make use of both laparoscopic and transvaginal methods to perform a successful repair with a minimally invasive and safe technique. Conclusion: Laparoscopically assisted vaginal cuff suturing for vaginal cuff dehiscence after total laparoscopic hysterectomy was found to be effective, safe, and minimally invasive. Keywords: Vaginal cuff dehiscence, Vaginal cuff repair, Vaginal cuff evisceration, Laparoscopic hysterectomy, Complication

  11. Method of making a multi-electrode double layer capacitor having single electrolyte seal and aluminum-impregnated carbon cloth electrodes

    Science.gov (United States)

    Farahmandi, C. Joseph; Dispennette, John M.; Blank, Edward; Kolb, Alan C.

    2002-09-17

    A single cell, multi-electrode high performance double layer capacitor includes first and second flat stacks of electrodes adapted to be housed in a closeable two-part capacitor case which includes only a single electrolyte seal. Each electrode stack has a plurality of electrodes connected in parallel, with the electrodes of one stack being interleaved with the electrodes of the other stack to form an interleaved stack, and with the electrodes of each stack being electrically connected to respective capacitor terminals. A porous separator is positioned against the electrodes of one stack before interleaving to prevent electrical shorts between the electrodes. The electrodes are made by folding a compressible, low resistance, aluminum-impregnated carbon cloth, made from activated carbon fibers, around a current collector foil, with a tab of the foils of each electrode of each stack being connected in parallel and connected to the respective capacitor terminal. The height of the interleaved stack is somewhat greater than the inside height of the closed capacitor case, thereby requiring compression of the interleaved electrode stack when placed inside of the case, and thereby maintaining the interleaved electrode stack under modest constant pressure. The closed capacitor case is filled with an electrolytic solution and sealed. A preferred electrolytic solution is made by dissolving an appropriate salt into acetonitrile (CH.sub.3 CN). In one embodiment, the two parts of the capacitor case are conductive and function as the capacitor terminals.

  12. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  13. A systematic review of studies on anatomical position of electrode contacts used for chronic subthalamic stimulation in Parkinson's disease.

    Science.gov (United States)

    Caire, François; Ranoux, Danièle; Guehl, Dominique; Burbaud, Pierre; Cuny, Emmanuel

    2013-09-01

    The dorso-lateral part of the subthalamic nucleus (STN) is considered as the usual target of deep brain stimulation for Parkinson's disease. Nevertheless, the exact anatomical location of the electrode contacts used for chronic stimulation is still a matter of debate. The aim of this study was to perform a systematic review of the existing literature on this issue. We searched for studies on the anatomical location of active contacts published until December 2012. We identified 13 studies, published between 2002 and 2010, including 260 patients and 466 electrodes. One hundred and sixty-four active contacts (35 %) were identified within the STN, 117 (25 %) at the interface between STN and the surrounding structures, 184 (40 %) above the STN and one within the substantia nigra. We observed great discrepancies between the different series. The contra-lateral improvement was between 37 and 78.5 % for contacts located within the STN, between 48.6 and 73 % outside the STN, between 65.3 and 66 % at the interface. The authors report no clear correlation between anatomical location and stimulation parameters. Post-operative analysis of the anatomical location of active contacts is difficult, and all the methods used are debatable. The relationship between the anatomical location of active contacts and the clinical effectiveness of stimulation is unclear. It would be necessary to take into account the volume of the electrode contacts and the diffusion of the stimulation. We can nevertheless assume that the interface between dorso-lateral STN, zona incerta and Forel's fields could be directly involved in the effects of stimulation.

  14. Glenohumeral joint translation and muscle activity in patients with symptomatic rotator cuff pathology: An ultrasonographic and electromyographic study with age-matched controls.

    Science.gov (United States)

    Rathi, Sangeeta; Taylor, Nicholas F; Soo, Brendan; Green, Rodney A

    2018-03-02

    To determine whether patients with symptomatic rotator cuff pathology had more glenohumeral joint translation and different patterns of rotator cuff muscle activity compared to controls. Repeated measurements of glenohumeral translation and muscle activity in two positions and six testing conditions in two groups. Twenty participants with a symptomatic and diagnosed rotator cuff tear and 20 age, and gender matched controls were included. Neuromuscular activity was tested by inserting intramuscular electrodes in the rotator cuff muscles. Anterior and posterior glenohumeral translations were measured using real time ultrasound in testing conditions (with and without translation force, with and without isometric internal and external rotation), in two positions (shoulder neutral, 90° of abduction) and two force directions (anterior, posterior). Symptomatic pathology group demonstrated increased passive glenohumeral translation with posterior translation force (protator cuff muscle contraction in the pathology group limited joint translation in a similar manner to the control group, but they did not show the normal direction specific pattern in the neutral posterior position (protator cuff still controlled glenohumeral translation. These results highlight the need to consider joint translation in the assessment and management of patients with rotator cuff injury. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Ethylene Removal in Strong Electric Field Formed by Floating Multi-Electrode

    Science.gov (United States)

    Nagasawa, Takeshi

    Ethylene gas that contains the acetic acid ester element can be removed by applying the pulse voltage to the floating multi-electrode device. This phenomenon is caused in the weak discharge by the strong electric field between the narrow electrodes. This device is possible in very small electric power (apples, and 3.5ppm/30min for 2 melons. However, ethylene gas that doesn't contain the acetic acid ester cannot be removed (ex. ethylene pure gas and Japanese apricot).

  16. Reduced contact resistance of a-IGZO thin film transistors with inkjet-printed silver electrodes

    Science.gov (United States)

    Chen, Jianqiu; Ning, Honglong; Fang, Zhiqiang; Tao, Ruiqiang; Yang, Caigui; Zhou, Yicong; Yao, Rihui; Xu, Miao; Wang, Lei; Peng, Junbiao

    2018-04-01

    In this study, high performance amorphous In–Ga–Zn–O (a-IGZO) TFTs were successfully fabricated with inkjet-printed silver source-drain electrodes. The results showed that increased channel thickness has an improving trend in the properties of TFTs due to the decreased contact resistance. Compared with sputtered silver TFTs, devices with printed silver electrodes were more sensitive to the thickness of active layer. Furthermore, the devices with optimized active layer showed high performances with a maximum saturation mobility of 8.73 cm2 · V‑1 · S‑1 and an average saturation mobility of 6.97 cm2 · V‑1 · S‑1, I on/I off ratio more than 107 and subthreshold swing of 0.28 V/decade, which were comparable with the analogous devices with sputtered electrodes.

  17. Amperometric nitrite sensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and poly(toluidine blue)

    International Nuclear Information System (INIS)

    Dai, Juan; Deng, Fei; He, Shuang; Deng, Dongli; Yuan, Yali; Zhang, Jinzhong

    2016-01-01

    An amperometric nitrite sensor modified with multi-walled carbon nanotubes (MWCNTs) and poly(toluidine blue) (PTB) on glassy carbon electrode was constructed. The surface morphology of the composite- modified electrode was characterized by scanning electron microscopy, and the electrochemical response behavior and electrocatalytic oxidation mechanism of nitrite were investigated by cyclic voltammetry. The high surface-to-volume ratio of MWCNTs and PTB brings the electrochemical sensing unit and nitrite in full contact. This renders the electrochemical response extremely sensitive to nitrite. Under the optimal measurement conditions and a working voltage of 0.73 V (vs. SCE), a linear relationship is obtained between the oxidation peak current and nitrite concentration in the range of 39 nM–1.1 mM, and the limit of detection is lowered to 19 nM (at an S/N ratio of 3). The sensor was successfully applied to the determination of nitrite in greenhouse soils. (author)

  18. Tracheal cuff pressure monitoring in the ICU: a literature review and survey of current practice in Queensland.

    Science.gov (United States)

    Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D

    2014-11-01

    The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.

  19. An automated online positioning system and simulation environment for multi-electrodes in extracellular recordings

    DEFF Research Database (Denmark)

    Franke, Felix; Natora, Michal; Meier, Philipp

    2010-01-01

    to tissue drifts and other sources of variability in the recording setup, the position of the electrodes with respect to the recorded neurons can change causing low recording quality. The contributions of this work are threefold. We introduce a quality measure for the recording position of the electrode...... which should be maximized during recordings and is especially suitable for the use of multi-electrodes. An automated positioning system based on this quality measure is proposed. The system is able to find favorable recording positions and adapts the electrode position smoothly to changes of the neuron...

  20. The Effect of Scala Tympani Morphology on Basilar Membrane Contact With a Straight Electrode Array: A Human Temporal Bone Study.

    Science.gov (United States)

    Verberne, Juul; Risi, Frank; Campbell, Luke; Chambers, Scott; O'Leary, Stephen

    2017-01-01

    Scala tympani morphology influences the insertion dynamics and intra-scalar position of straight electrode arrays. Hearing preservation is the goal of cochlear implantation with current thin straight electrode arrays. These hug the lateral wall, facilitating full, atraumatic insertions. However, most studies still report some postoperative hearing loss. This study explores the influence of scala tympani morphology on array position relative to the basilar membrane and its possible contribution to postoperative hearing loss. Twenty-six fresh-frozen human temporal bones implanted with a straight electrode array were three-dimensionally reconstructed from micro-photographic histological sections. Insertion depth and the proximity between the array and basilar membrane were recorded. Lateral wall shape was quantified as a curvature ratio. Insertion depths ranged from 233 to 470 degrees. The mean first point of contact between the array and basilar membrane was 185 degrees; arrays tended to remain in contact with the membrane after first contacting it. Eighty-nine and 93% of arrays that reached the upper basal (>240-360 degrees) and second (>360-720 degrees) turns respectively contacted the basilar membrane in these regions. Scalar wall curvature ratio decreased significantly (the wall became steeper) from the basal to second turns. This shift correlated with a reduced distance between the array and basilar membrane. Scala tympani morphology influences the insertion dynamics and intra-scalar position of a straight electrode array. In addition to gross trauma of cochlear structures, contact between the array and basilar membrane and how this impacts membrane function should be considered in hearing preservation cases.

  1. A multi-pad electrode based functional electrical stimulation system for restoration of grasp

    Directory of Open Access Journals (Sweden)

    Malešević Nebojša M

    2012-09-01

    Full Text Available Abstract Background Functional electrical stimulation (FES applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. Methods The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. Results The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments.

  2. The role of pectoralis major and latissimus dorsi muscles in a biomechanical model of massive rotator cuff tear.

    Science.gov (United States)

    Campbell, Sean T; Ecklund, Kier J; Chu, Eileen H; McGarry, Michelle H; Gupta, Ranjan; Lee, Thay Q

    2014-08-01

    Superior migration of the humeral head after massive rotator cuff tear (mRCT) is thought to lead to cuff tear arthropathy. Previous biomechanical studies have demonstrated the ability of the pectoralis major and latissimus dorsi (PM/LD) muscles to resist this migration. This study examined the role of PM/LD muscles on glenohumeral joint forces and acromiohumeral contact pressures in a mRCT model. Six cadaveric shoulders were tested using a custom shoulder-testing system. Muscle insertions of the rotator cuff, deltoid, and PM/LD were preserved and used for muscle loading. Specimens were tested in 3 different humeral rotation positions at 0° abduction and 2 rotation positions at 60° abduction. Testing was performed for intact specimens, after supraspinatus removal, and after supraspinatus/infraspinatus/teres minor removal. PM/LD were loaded or unloaded to determine their effect. Humeral head kinematics, glenohumeral joint forces, and acromiohumeral contact area and pressure were measured. For the mRCT condition at 0° abduction, unloading the PM/LD resulted in superior shift of the humeral head. Acromiohumeral contact pressures were undetectable when the PM/LD were loaded but increased significantly after PM/LD unloading. After mRCT, superior joint forces were increased and compressive forces were decreased compared with intact; loading the PM/LD resolved these abnormal forces in some testing conditions. In mRCT, the PM and LD muscles are effective in improving glenohumeral kinematics and reducing acromiohumeral pressures. Strengthening or neuromuscular training of this musculature, or both, may delay the progression to cuff tear arthropathy. Published by Mosby, Inc.

  3. High-performance flexible supercapacitor based on porous array electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Shieh, Jen-Yu; Tsai, Sung-Ying; Li, Bo-Yan [Institute of Electro-Optical and Materials Science, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China); Yu, Hsin Her, E-mail: hhyu@nfu.edu.tw [Department of Biotechnology, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China)

    2017-07-01

    In this study, an array of polystyrene (PS) spheres was synthesized by a dispersion-polymerization technique as a template onto which a porous polydimethylsiloxane (PDMS) microarray structure was fabricated by soft lithography. A conducting layer was coated on the surface of the microarray after a suspension of multi-walled carbon nanotubes (MWCNTs) mixed with graphene (G) had been poured into the porous array. A PDMS-based porous supercapacitor was assembled by sandwiching a separator between two porous electrodes filled with a H{sub 3}PO{sub 4}/polyvinyl alcohol (PVA) gel electrolyte. The specific capacitance, electrochemical properties, and cycle stability of the porous electrode supercapacitors were explored. The porous PDMS-electrode-based supercapacitor exhibited high specific capacitance and good cycle stability, indicating its enormous potential for future applications in wearable and portable electronic products. - Highlights: • Porous electrode was prepared using an array of polystyrene spheres as template. • The porous electrodes provided increased contact area with the electrolyte. • A gel electrolyte averted problems with leakage and poor interfacial contact. • A larger separator pore size effectively reduced the internal resistance, iR{sub drop}. • Porous PDMS supercapacitor showed superior flexibility and cycling stability.

  4. Evaluation of metal–nanowire electrical contacts by measuring contact end resistance

    International Nuclear Information System (INIS)

    Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung

    2012-01-01

    It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)

  5. Endotracheal Tube Cuff Management at Altitude

    Science.gov (United States)

    2014-02-05

    the volume of saliva, if any, leaking around ETT cuffs. To simulate the clinical environment, four transport ventilators (Model 731, Impact...ETT. Table 1. Changes in ETT Cuff Pressure during the Study Method Sea Level (Baseline)a 8,000 fta Sea Level (Post-Flight)a 7.5 mm 8.0 mm...threshold typically required to prevent aspiration of secretions around the cuff. These findings have important clinical implications, as cuff

  6. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Anchoring alpha-manganese oxide nanocrystallites on multi-walled carbon nanotubes as electrode materials for supercapacitor

    Energy Technology Data Exchange (ETDEWEB)

    Li Li; Qin Zongyi, E-mail: phqin@dhu.edu.cn; Wang Lingfeng; Liu Hongjin; Zhu Meifang [Donghua University, State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering (China)

    2010-09-15

    The partial coverage of manganese oxide (MnO{sub 2}) particles was achieved on the surfaces of multi-walled carbon nanotubes (MWCNTs) through a facile hydrothermal process. These particles were demonstrated to be alpha-manganese dioxide ({alpha}-MnO{sub 2}) nanocrystallites, and exhibited the appearance of the whisker-shaped crystals with the length of 80-100 nm. In such a configuration, the uncovered CNTs in the nanocomposite acted as a good conductive pathway and the whisker-shaped MnO{sub 2} nanocrystallites efficiently increased the contact of the electrolyte with the active materials. Thus, the highest specific capacitance of 550 F g{sup -1} was achieved using the resulting nanocomposites as the supercapacitor electrode. In addition, the enhancement of the capacity retention was observed, with the nanocomposite losing only 10% of the maximum capacity after 1,500 cycles.

  8. A single camera photogrammetry system for multi-angle fast localization of EEG electrodes.

    Science.gov (United States)

    Qian, Shuo; Sheng, Yang

    2011-11-01

    Photogrammetry has become an effective method for the determination of electroencephalography (EEG) electrode positions in three dimensions (3D). Capturing multi-angle images of the electrodes on the head is a fundamental objective in the design of photogrammetry system for EEG localization. Methods in previous studies are all based on the use of either a rotating camera or multiple cameras, which are time-consuming or not cost-effective. This study aims to present a novel photogrammetry system that can realize simultaneous acquisition of multi-angle head images in a single camera position. Aligning two planar mirrors with the angle of 51.4°, seven views of the head with 25 electrodes are captured simultaneously by the digital camera placed in front of them. A complete set of algorithms for electrode recognition, matching, and 3D reconstruction is developed. It is found that the elapsed time of the whole localization procedure is about 3 min, and camera calibration computation takes about 1 min, after the measurement of calibration points. The positioning accuracy with the maximum error of 1.19 mm is acceptable. Experimental results demonstrate that the proposed system provides a fast and cost-effective method for the EEG positioning.

  9. Contact geometry at the undersurface of the acromion with and without a rotator cuff tear.

    Science.gov (United States)

    Lee, S B; Itoi, E; O'Driscoll, S W; An, K N

    2001-04-01

    The purpose of this study was to investigate the difference in contact geometry at the undersurface of acromion in shoulders with and without a rotator cuff (RC) tear. Case-control study. Forty fresh cadaveric shoulders (average age at death, 61 years) without gross osteoarthritic changes were divided into the intact RC group (n = 20) and the RC tear group (n = 20). Clinical impingement was simulated by compressing the humeral head and the intact portion of the RC against the coracoacromial arch with an axial compressive force of 25 kg while the humerus was held abducted 20 degrees in the scapular plane. The contact pattern between the acromion and the RC was measured with Fuji Prescale super low-pressure-sensitive film (Fuji Photo Film Co, Ltd, Tokyo, Japan). The imprint image was analyzed using Global Lab image software (Automatix, Marlboro, MA). The percentage of the maximum anteroposterior dimension of the imprint on Fuji film to the anteroposterior diameter of the acromial undersurface was 29% +/- 9% in intact RC shoulders, and 39% +/- 13% in shoulders with an RC tear (P >.05). The percentage of the maximum mediolateral dimension of the imprint to the mediolateral diameter of the corresponding part of the acromial undersurface was 27% +/- 12% in intact RC shoulders, and 48% +/- 11% in shoulders with an RC tear. This difference was statistically significant (P RC in the anteroposterior dimension, which might be related to the appearance in supraspinatus outlet view, was not significantly different between shoulders with and without an RC tear. These findings suggest that factors other than acromial shape play a significant role in the pathogenesis of RC tears. The implication regarding the role of acromioplasty remains to be clarified.

  10. Preparation of electrodes on cfrp composites with low contact resistance comprising laser-based surface pre-treatment

    KAUST Repository

    Almuhammadi, Khaled Hamdan; Lubineau, Gilles; Alfano, Marco Francesco; Buttner, Ulrich

    2016-01-01

    Various examples are provided related to the preparation of electrodes on carbon fiber reinforced polymer (CFRP) composites with low contact resistance. Laser-based surface preparation can be used for bonding to CFRP composites. In one example, a

  11. Rotator cuff disease

    International Nuclear Information System (INIS)

    Ziatkin, M.B.; Iannotti, J.P.; Roberts, M.; Dalinka, M.K.; Esterhai, J.L.; Kressel, H.Y.; Lenkinski, R.E.

    1988-01-01

    A dual-surface-coil array in a Helmholtz configuration was used to evaluate th rotator cuff in ten normal volunteers and 44 patients. Studies were performed with a General Electric 1.5-T MR imager. Thirty-two patients underwent surgery, 25 of whom also underwent arthrography. In comparison with surgery, MR imaging was more sensitive than arthrography for rotator cuff tears (91% vs 71%). The specificity and accuracy of MR imaging were 88% and 91%. The accuracy increased with use of an MR grading system. MR findings correlated with surgical findings with regard to the size and site of tears. MR findings of cuff tears were studied with multivariate analysis. Correlation was also found between a clinical score, the MR grade, and the clinical outcome

  12. Beyond Slurry-Cast Supercapacitor Electrodes: PAN/MWNT Heteromat-Mediated Ultrahigh Capacitance Electrode Sheets

    Science.gov (United States)

    Lee, Jung Han; Kim, Jeong A.; Kim, Ju-Myung; Lee, Sun-Young; Yeon, Sun-Hwa; Lee, Sang-Young

    2017-01-01

    Supercapacitors (SCs) have garnered considerable attention as an appealing power source for forthcoming smart energy era. An ultimate challenge facing the SCs is the acquisition of higher energy density without impairing their other electrochemical properties. Herein, we demonstrate a new class of polyacrylonitrile (PAN)/multi-walled carbon tube (MWNT) heteromat-mediated ultrahigh capacitance electrode sheets as an unusual electrode architecture strategy to address the aforementioned issue. Vanadium pentoxide (V2O5) is chosen as a model electrode material to explore the feasibility of the suggested concept. The heteromat V2O5 electrode sheets are produced through one-pot fabrication based on concurrent electrospraying (for V2O5 precursor/MWNT) and electrospinning (for PAN nanofiber) followed by calcination, leading to compact packing of V2O5 materials in intimate contact with MWNTs and PAN nanofibers. As a consequence, the heteromat V2O5 electrode sheets offer three-dimensionally bicontinuous electron (arising from MWNT networks)/ion (from spatially reticulated interstitial voids to be filled with liquid electrolytes) conduction pathways, thereby facilitating redox reaction kinetics of V2O5 materials. In addition, elimination of heavy metallic foil current collectors, in combination with the dense packing of V2O5 materials, significantly increases (electrode sheet-based) specific capacitances far beyond those accessible with conventional slurry-cast electrodes.

  13. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  14. Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.

    Science.gov (United States)

    Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep

    2014-01-01

    A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.

  15. Proteomics perspectives in rotator cuff research

    DEFF Research Database (Denmark)

    Sejersen, Maria Hee Jung; Frost, Poul; Hansen, Torben Bæk

    2015-01-01

    Background Rotator cuff tendinopathy including tears is a cause of significant morbidity. The molecular pathogenesis of the disorder is largely unknown. This review aimed to present an overview of the literature on gene expression and protein composition in human rotator cuff tendinopathy and other...... studies on objectively quantified differential gene expression and/or protein composition in human rotator cuff tendinopathy and other tendinopathies as compared to control tissue. Results We identified 2199 studies, of which 54 were included; 25 studies focussed on rotator cuff or biceps tendinopathy......, which only allowed simultaneous quantification of a limited number of prespecified mRNA molecules or proteins, several proteins appeared to be differentially expressed/represented in rotator cuff tendinopathy and other tendinopathies. No proteomics studies fulfilled our inclusion criteria, although...

  16. A new method synthesis polyaniline/multi-walled carbon nanotube composites for supercapacitor electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Pan, J.; Wei, X.; Zhou, S.P. [Shandong Univ. of Technology, Zibo (China). School of Chemical Engineering

    2010-07-01

    A series of polyaniline multi-walled nanotube (PANIMWNT) composite films were prepared using an in situ polymerization technique. Scanning electron microscopy (SEM) was used to characterize the morphology and microstructure of the samples. Cyclic voltammetry (CV), impedance spectroscopy, and galvanostatic charge/discharge analyses were used to determine the electrochemical properties of the PANIMWNT films in a 3-electrode system. The electrochemical performance of PANI, PANIMWNT, and MWNT film performances was then compared. Results of the study showed that the PANI electrodes showed a much higher capacitance than the MWNT and PANIMWNT electrodes. Both the PANI and PANIMWNT nanocomposites showed good electrochemical capacitance. The improved performance of the electrodes was attributed to the presence of sodium hypochlorite (NaClO). 5 refs.

  17. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    Science.gov (United States)

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these

  18. On cuff imbalance and tripolar ENG amplifier configurations.

    Science.gov (United States)

    Triantis, Iasonas F; Demosthenous, Andreas; Donaldson, Nick

    2005-02-01

    Electroneurogram (ENG) recording techniques benefit from the use of tripolar cuffs because they assist in reducing interference from sources outside the cuff. However, in practice the performance of ENG amplifier configurations, such as the quasi-tripole and the true-tripole, has been widely reported to be degraded due to the departure of the tripolar cuff from ideal behavior. This paper establishes the presence of cuff imbalance and investigates its relationship to cuff asymmetry, cuff end-effects and interference source proximity. The paper also presents a comparison of the aforementioned amplifier configurations with a new alternative, termed the adaptive-tripole, developed to automatically compensate for cuff imbalance. The output signal-to-interference ratio of the three amplifier configurations were compared in vivo for two interference signals (stimulus artifact and M-wave) superimposed on compound action potentials. The experiments showed (for the first time) that the two interference signals result in different cuff imbalance values. Nevertheless, even with two distinct cuff imbalances present, the adaptive-tripole performed better than the other two systems in 61.9% of the trials.

  19. A Case Report of an Acromioclavicular Joint Ganglion Associated with a Rotator Cuff Tear.

    Science.gov (United States)

    Tanaka, Suguru; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2017-04-13

    We report a case of subcutaneous ganglion adjacent to the acromioclavicular joint with massive rotator cuff tear [1-7]. An 81-year-old woman presented with a ganglion adjacent to the acromioclavicular joint that had first been identified 9 months earlier. The ganglion had recurred after having been aspirated by her local physician, so she was referred to our hospital. The puncture fluid was yellowish, clear and viscous. Magnetic resonance imaging identified a massive rotator cuff tear with multi- lobular cystic lesions continuous to the acromioclavicular joint, presenting the "geyser sign". During arthroscopy, distal clavicular resection and excision of the ganglion were performed together with joint debridement. At present, the ganglion has not recurred and the patient has returned to normal daily activity. In this case, the ganglion may have developed subsequent to the concomitant massive cuff tear, due to subcutaneous fluid flow through the damaged acromioclavicular joint.

  20. MRI of the rotator cuff and internal derangement

    Energy Technology Data Exchange (ETDEWEB)

    Opsha, Oleg [Department of Radiology, Maimonides Medical Center, 4802 10th Avenue, Brooklyn, NY 11219 (United States)], E-mail: oopsha@hotmail.com; Malik, Archana [Department of Radiology, Maimonides Medical Center, 4802 10th Avenue, Brooklyn, NY 11219 (United States)], E-mail: dr.armal@gmail.com; Baltazar, Romulo [Department of Radiology, Maimonides Medical Center, 4802 10th Avenue, Brooklyn, NY 11219 (United States)], E-mail: rbaltazar@gmail.com; Primakov, Denis [Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, NY 11030 (United States)], E-mail: dgprim@yahoo.com; Beltran, Salvador [Dr. Ramon Marti, 2 Albons, Ginrona 17136 (Spain); Miller, Theodore T. [Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 (United States)], E-mail: MillerTT@hss.edu; Beltran, Javier [Department of Radiology, Maimonides Medical Center, 4802 10th Avenue, Brooklyn, NY 11219 (United States)], E-mail: jbeltran46@msn.com

    2008-10-15

    Disease to the rotator cuff is the most common cause of shoulder pain and dysfunction in adults. This group of muscles performs multiple functions and is often stressed during various activities. The anatomy and physiology of the rotator cuff is complex and interconnected to other muscle groups in the shoulder. One must take the anatomic status of the rotator cuff tendons into account when planning the treatment of the rotator cuff injury. Diagnostic imaging of the rotator cuff, performed by MRI, provides valuable information about the nature of the injury. In this article, we will review the various types and causes of rotator cuff injuries, normal MR anatomy, function, patho-anatomy, and the biomechanics of the rotator cuff. We will also review shoulder impingement syndromes.

  1. MRI of the rotator cuff and internal derangement

    International Nuclear Information System (INIS)

    Opsha, Oleg; Malik, Archana; Baltazar, Romulo; Primakov, Denis; Beltran, Salvador; Miller, Theodore T.; Beltran, Javier

    2008-01-01

    Disease to the rotator cuff is the most common cause of shoulder pain and dysfunction in adults. This group of muscles performs multiple functions and is often stressed during various activities. The anatomy and physiology of the rotator cuff is complex and interconnected to other muscle groups in the shoulder. One must take the anatomic status of the rotator cuff tendons into account when planning the treatment of the rotator cuff injury. Diagnostic imaging of the rotator cuff, performed by MRI, provides valuable information about the nature of the injury. In this article, we will review the various types and causes of rotator cuff injuries, normal MR anatomy, function, patho-anatomy, and the biomechanics of the rotator cuff. We will also review shoulder impingement syndromes

  2. Electromyographic study of rotator cuff muscle activity during full and empty can tests

    Directory of Open Access Journals (Sweden)

    Yoshihiro Kai

    2015-01-01

    Full Text Available The empty can (EC and full can (FC tests are used as diagnostic tools for patients with rotator cuff disease. However, recently concerns have been raised that these tests do not selectively activate the muscle. Therefore, the purpose of this study was to evaluate the rotator cuff muscle activation levels during the EC and FC tests in various positions using electromyography. Twelve healthy, right-handed men without shoulder complaints (mean age: 26.1 years, range: 23–35 years were included. The tests were performed isometrically with the shoulder elevated at 45° and 90° in the sagittal, scapular, and coronal planes, either in the thumb-up (FC test or thumb-down (EC test positions. During these positions, the electromyographic signal was recorded simultaneously from the four shoulder muscles using a combination of surface and intramuscular fine-wire electrodes. The average activation of the supraspinatus and subscapularis was greater during the EC test than during the FC test and in the scapular and coronal planes than in the sagittal plane at 90°. For the infraspinatus, there were no significant differences in any positions between the two tests. Thus, the rotator cuff muscles are influenced by arm position and the elevation plane during the EC and FC tests.

  3. US detection of rotator cuff tear

    International Nuclear Information System (INIS)

    Soble, M.G.; Guay, R.C.; Kaye, A.D.

    1988-01-01

    Between June 1986 and April 1988, 75 patients suspected of having a tear of the rotator cuff underwent shoulder sonography and arthrography. Compared with anthrography, US demonstrated 92% of rotor cuff tears, with a specificity of 84% and a negative predictive value of 95%. In 30 patients who underwent surgery for a rotator cuff tear or other soft-tissue abnormality, sonography demonstrated a sensitivity of 93% and specificity of 73%, while arthrography demonstrated a sensitivity of 87% and specificity of 100%. The above data indicate that US is a useful, noninvasive screening procedure for patients suspected of having rotator cuff injury

  4. A comparison study of electrodes for neonate electrical impedance tomography

    International Nuclear Information System (INIS)

    Rahal, Mohamad; Demosthenous, Andreas; Khor, Joo Moy; Tizzard, Andrew; Bayford, Richard

    2009-01-01

    Electrical impedance tomography (EIT) is an imaging technique that has the potential to be used for studying neonate lung function. The properties of the electrodes are very important in multi-frequency EIT (MFEIT) systems, particularly for neonates, as the skin cannot be abraded to reduce contact impedance. In this work, the impedance of various clinical electrodes as a function of frequency is investigated to identify the optimum electrode type for this application. Six different types of self-adhesive electrodes commonly used in general and neonatal cardiology have been investigated. These electrodes are Ag/AgCl electrodes from the Ambu® Cardiology Blue sensors range (BR, NF and BRS), Kendall (KittyCat(TM) and ARBO®) and Philips 13953D electrodes. In addition, a textile electrode without gel from Textronics was tested on two subjects to allow comparison with the hydrogel-based electrodes. Two- and four-electrode measurements were made to determine the electrode-interface and tissue impedances, respectively. The measurements were made on the back of the forearm of six healthy adult volunteers without skin preparation with 2.5 cm electrode spacing. Impedance measurements were carried out using a Solartron SI 1260 impedance/gain-phase analyser with a frequency range from 10 Hz to 1 MHz. For the electrode-interface impedance, the average magnitude decreased with frequency, with an average value of 5 kΩ at 10 kHz and 337 Ω at 1 MHz; for the tissue impedance, the respective values were 987 Ω and 29 Ω. Overall, the Ambu BRS, Kendall ARBO® and Textronics textile electrodes gave the lowest electrode contact impedance at 1 MHz. Based on the results of the two-electrode measurements, simple RC models for the Ambu BRS and Kendall-ARBO and Textronics textile electrodes have been derived for MFEIT applications

  5. Magnetoresistance in cobalt-contacted multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    Vinzelberg, H.; Zhao, B.; Moench, I.; Schumann, J.; Schneider, C.M.

    2005-01-01

    We present results for magnetotransport measurements on multiwall-carbon nanotubes (MWCNT) contacted by cobalt electrodes. By measuring the V(I) characteristics at constant magnetic fields and different orientation of the magnetization directions in the Co electrodes, we were able to determine both current and voltage dependences of the magnetoresistance (MR) effects. These tunneling MR values are compared with the directly measured MR at constant current with sweeping magnetic field. The V(I) curves show an ohmic behavior at 295 K and a non-linear tunneling behavior at 4.2 K. With decreasing bias current the MR increased up to 60% at 4.2 K, and with decreasing bias voltages even up to 175%. The MR disappears at high bias current (voltages) and temperatures higher than 40 K. For most of the samples the current dependences of the MR were found to be nearly symmetric upon reversing the current direction. However, in some cases we also observed a sign change of the MR as function of the applied current, which suggests an inversion of the spin polarization in one of the Co interfaces

  6. Design and manufacture of multi-electrode ion chamber for absolute photon-flux measurements of soft x-rays

    International Nuclear Information System (INIS)

    Yoshigoe, Akitaka; Teraoka, Yuden

    2001-03-01

    In order to measure the absolute photon-flux of soft x-rays at the photon energy region from 500 eV to 1500 eV, a sealed gas ion chamber with multi-electrodes was designed and manufactured. Actually we succeeded in measuring the photon-flux at the soft x-ray beamline, BL23SU, in the SPring-8. This report concretely describes the design and the adjustment of the sealed gas ion chamber with multi-electrodes. (author)

  7. The Rotator Cuff Organ: Integrating Developmental Biology, Tissue Engineering, and Surgical Considerations to Treat Chronic Massive Rotator Cuff Tears.

    Science.gov (United States)

    Rothrauff, Benjamin B; Pauyo, Thierry; Debski, Richard E; Rodosky, Mark W; Tuan, Rocky S; Musahl, Volker

    2017-08-01

    The torn rotator cuff remains a persistent orthopedic challenge, with poor outcomes disproportionately associated with chronic, massive tears. Degenerative changes in the tissues that comprise the rotator cuff organ, including muscle, tendon, and bone, contribute to the poor healing capacity of chronic tears, resulting in poor function and an increased risk for repair failure. Tissue engineering strategies to augment rotator cuff repair have been developed in an effort to improve rotator cuff healing and have focused on three principal aims: (1) immediate mechanical augmentation of the surgical repair, (2) restoration of muscle quality and contractility, and (3) regeneration of native enthesis structure. Work in these areas will be reviewed in sequence, highlighting the relevant pathophysiology, developmental biology, and biomechanics, which must be considered when designing therapeutic applications. While the independent use of these strategies has shown promise, synergistic benefits may emerge from their combined application given the interdependence of the tissues that constitute the rotator cuff organ. Furthermore, controlled mobilization of augmented rotator cuff repairs during postoperative rehabilitation may provide mechanotransductive cues capable of guiding tissue regeneration and restoration of rotator cuff function. Present challenges and future possibilities will be identified, which if realized, may provide solutions to the vexing condition of chronic massive rotator cuff tears.

  8. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    Directory of Open Access Journals (Sweden)

    Lin Yang

    Full Text Available Frequency-difference electrical impedance tomography (fdEIT reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz. In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  9. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    Science.gov (United States)

    Yang, Lin; Dai, Meng; Xu, Canhua; Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  10. Braided multi-electrode probes: mechanical compliance characteristics and recordings from spinal cords

    Science.gov (United States)

    Kim, Taegyo; Branner, Almut; Gulati, Tanuj; Giszter, Simon F.

    2013-08-01

    Objective. To test a novel braided multi-electrode probe design with compliance exceeding that of a 50 µm microwire, thus reducing micromotion- and macromotion-induced tissue stress. Approach. We use up to 24 ultra-fine wires interwoven into a tubular braid to obtain a highly flexible multi-electrode probe. The tether-portion wires are simply non-braided extensions of the braid structure, allowing the microprobe to follow gross neural tissue movements. Mechanical calculation and direct measurements evaluated bending stiffness and axial compression forces in the probe and tether system. These were compared to 50 µm nichrome microwire standards. Recording tests were performed in decerebrate animals. Main results. Mechanical bending tests on braids comprising 9.6 or 12.7 µm nichrome wires showed that implants (braided portions) had 4 to 21 times better mechanical compliance than a single 50 µm wire and non-braided tethers were 6 to 96 times better. Braided microprobes yielded robust neural recordings from animals' spinal cords throughout cord motions. Significance. Microwire electrode arrays that can record and withstand tissue micro- and macromotion of spinal cord tissues are demonstrated. This technology may provide a stable chronic neural interface into spinal cords of freely moving animals, is extensible to various applications, and may reduce mechanical tissue stress.

  11. Clinical indicators associated with successful tracheostomy cuff deflation.

    Science.gov (United States)

    Pryor, Lee N; Ward, Elizabeth C; Cornwell, Petrea L; O'Connor, Stephanie N; Chapman, Marianne J

    2016-08-01

    Tracheostomy cuff deflation is a necessary stage of the decannulation pathway, yet the optimal clinical indicators to guide successful cuff deflation are unknown. The study aims were to identify (1) the proportion of patients tolerating continuous cuff deflation at first attempt; (2) the clinical observations associated with cuff deflation success or failure, including volume of above cuff secretions and (3) the predictive capacity of these observations within a heterogeneous cohort. A retrospective review of 113 acutely tracheostomised patients with a subglottic suction tube in situ was conducted. Ninety-five percent of patients (n=107) achieved continuous cuff deflation on the first attempt. The clinical observations recorded as present in the 24h preceding cuff deflation included: (1) medical stability, (2) respiratory stability, (3) fraction of inspired oxygen ≤0.4, (4) tracheal suction ≤1-2 hourly, (5) sputum thin and easy to suction, (6) sputum clear or white, (7) ≥moderate cough strength, (8) above cuff secretions ≤1ml per hour and (9) alertness≥eyes open to voice. Using the presence of all 9 indicators as predictors of successful cuff deflation tolerance, specificity and positive predictive value were 100%, although sensitivity was only 77% and negative predictive value 19%. Refinement to a set of 3 clinically driven criteria (medical and respiratory stability, above cuff secretions ≤1ml/h) provided high specificity (100%), sensitivity (95%), positive predictive value (100%) and an improved negative predictive value (55%). Key criteria can help guide clinical decision-making on patient readiness for cuff deflation. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. Injection Therapies for Rotator Cuff Disease.

    Science.gov (United States)

    Lin, Kenneth M; Wang, Dean; Dines, Joshua S

    2018-04-01

    Rotator cuff disease affects a large proportion of the overall population and encompasses a wide spectrum of pathologies, including subacromial impingement, rotator cuff tendinopathy or tear, and calcific tendinitis. Various injection therapies have been used for the treatment of rotator cuff disease, including corticosteroid, prolotherapy, platelet-rich plasma, stem cells, and ultrasound-guided barbotage for calcific tendinitis. However, the existing evidence for these therapies remains controversial or sparse. Ultimately, improved understanding of the underlying structural and compositional deficiencies of the injured rotator cuff tissue is needed to identify the biological needs that can potentially be targeted with injection therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2013-07-01

    Full Text Available Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiration of oropharyngeal secretions. So we conducted a study to compare the prophylactic effects of polyurethane-cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes (ETT on ventilator-associated pneumonia. This randomized clinical trial was carried out in a 12 bed surgical intensive care unit. 96 patients expected to require mechanical ventilation more than 96 hours were randomly allocated to one of three following groups: Polyvinyl chloride cuff (PCV ETT, Polyurethane (PU cylindrical Sealguard ETT and PU Taperguard ETT. Cuff pressure monitored every three hours 3 days in all patients. Mean cuff pressure didn't have significant difference between three groups during 72 hours. Pneumonia was seen in 11 patients (34% in group PVC, 8 (25% in Sealguard and 7 (21% in Taperguard group. Changes in mean cuff pressure between Sealguard and PVC tubes and also between Taperguard and PVC tubes did not show any significant difference. There was no significant difference in overinflation between three groups. The use of ETT with PU material results in reducing ventilator-associated pneumonia compared to ETT with PVC cuff. In PU tubes Taperguard has less incidence of ventilator-associated pneumonia compared to Sealguard tubes.

  14. Rotator Cuff Injuries - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Rotator Cuff Injuries URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Rotator Cuff Injuries - Multiple Languages To use the sharing features ...

  15. Effect of electrode contact area on the information content of the recorded electrogastrograms: An analysis based on Rényi entropy and Teager-Kaiser Energy

    Science.gov (United States)

    Alagumariappan, Paramasivam; Krishnamurthy, Kamalanand; Kandiah, Sundravadivelu; Ponnuswamy, Mannar Jawahar

    2017-06-01

    Electrogastrograms (EGG) are electrical signals originating from the digestive system, which are closely correlated with its mechanical activity. Electrogastrography is an efficient non-invasive method for examining the physiological and pathological states of the human digestive system. There are several factors such as fat conductivity, abdominal thickness, change in electrode surface area etc, which affects the quality of the recorded EGG signals. In this work, the effect of variations in the contact area of surface electrodes on the information content of the measured electrogastrograms is analyzed using Rényi entropy and Teager-Kaiser Energy (TKE). Two different circular cutaneous electrodes with approximate contact areas of 201.14 mm2 and 283.64 mm2, have been adopted and EGG signals were acquired using the standard three electrode protocol. Further, the information content of the measured EGG signals were analyzed using the computed values of entropy and energy. Results demonstrate that the information content of the measured EGG signals increases by 6.72% for an increase in the contact area of the surface electrode by 29.09%. Further, it was observed that the average energy increases with increase in the contact surface area. This work appears to be of high clinical significance since the accurate measurement of EGG signals without loss in its information content, is highly useful for the design of diagnostic assistance tools for automated diagnosis and mass screening of digestive disorders.

  16. Occult Interpositional Rotator Cuff - an Extremely Rare Case of Traumatic Rotator Cuff Tear

    Energy Technology Data Exchange (ETDEWEB)

    Su, Wei Ren; Jou, I Ming [National Cheng Kung University Hospital, Tainan (China); Lin, Cheng Li [Show-Chwan Memorial Hospital, Changhua (China); Chih, Wei Hsing [Chia-Yi Christian Hospital, Chiayi (China)

    2012-01-15

    Traumatic interposition of a rotator cuff tendon in the glenohumeral joint without recognizable glenohumeral dislocation is an unusual complication after shoulder trauma. Here we report the clinical and imaging presentations of a 17-year-old man with trapped rotator cuff tendons in the glenohumeral joint after a bicycle accident. The possible trauma mechanism is also discussed.

  17. Effects of grid potentials and geometric dimensions on the multi-electrode probe measurements

    International Nuclear Information System (INIS)

    Elakshar, F.F.; Abdul El-Raoof, W.S.

    1986-01-01

    A hollow anode plasma source is used to produce low temperature plasma which is injected into a magnetic field. The effects of the grid potentials, collector potential and geometric dimensions on multi-electrode probe measurements, in the presence of a magnetic field, are investigated. It is found that the collector potential plays a substantial role in the measurement of temperatures and densities. The finite-size of the geometric dimensions of the probe influences the data and high values of temperature are obtained when a small ratio of the discriminator grid radius to the separation distance is used, providing that the repeller grid potentials is low. Reliable measurements can only be obtained if the multi-electrode probe is used in the presence of a magnetic field strong enough to reduce electron Larmor radii to less than the grid mesh radius. (author)

  18. NMR of the rotator cuff. An update

    International Nuclear Information System (INIS)

    Kreitner, Karl-Friedrich; Maehringer-Kunz, Aline

    2016-01-01

    The rotator cuff consists of the tendons of the supscapularis, supraspinatus, infraspinatus and teres minor muscles. This group of muscles performs multiple functions and is often stressed during various activities. This explains, why rotator cuff disease is common and the most often cause of shoulder pain and dysfunction in adults. MR imaging still is the most important imaging modality in assessment of rotator cuff disease. It enables the radiologist to make an accurate diagnosis, the basis for an appropriate management. In this article, current concepts with regard to anatomy and imaging diagnosis will be reviewed. The discussion of the complex anatomy is followed by normal and pathologic MR imaging appearances of the rotator cuff including tendinopathy and tearing, and concluding with a review of the postoperative cuff.

  19. Rotator cuff tear measurement by arthropneumotomography

    International Nuclear Information System (INIS)

    Kilcoyne, R.F.; Matsen, F.A. III

    1983-01-01

    Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size of the tear and the quality of the remaining cuff than did plain arthrograms

  20. Investigation of pentacene growth on SiO2 gate insulator after photolithography for nitrogen-doped LaB6 bottom-contact electrode formation

    Science.gov (United States)

    Maeda, Yasutaka; Hiroki, Mizuha; Ohmi, Shun-ichiro

    2018-04-01

    Nitrogen-doped (N-doped) LaB6 is a candidate material for the bottom-contact electrode of n-type organic field-effect transistors (OFETs). However, the formation of a N-doped LaB6 electrode affects the surface morphology of a pentacene film. In this study, the effects of surface treatments and a N-doped LaB6 interfacial layer (IL) were investigated to improve the pentacene film quality after N-doped LaB6 electrode patterning with diluted HNO3, followed by resist stripping with acetone and methanol. It was found that the sputtering damage during N-doped LaB6 deposition on a SiO2 gate insulator degraded the crystallinity of pentacene. The H2SO4 and H2O2 (SPM) and diluted HF treatments removed the damaged layer on the SiO2 gate insulator surface. Furthermore, the N-doped LaB6 IL improved the crystallinity of pentacene and realized dendritic grain growth. Owing to these surface treatments, the hole mobility improved from 2.8 × 10-3 to 0.11 cm2/(V·s), and a steep subthreshold swing of 78 mV/dec for the OFET with top-contact configuration was realized in air even after bottom-contact electrode patterning.

  1. 21 CFR 870.1120 - Blood pressure cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  2. Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation.

    Science.gov (United States)

    Zheng, Dingchang; Pan, Fan; Murray, Alan

    2013-10-01

    The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.

  3. Examination of rotator cuff re-tear

    International Nuclear Information System (INIS)

    Kitahara, Hiroyuki; Yabe, Yoshihiro; Norimatsu, Takahiro; Adachi, Shinji; Sera, Keisuke

    2010-01-01

    The six-month post-operative re-tear rate in 72 arthroscopic rotator cuff repair cases was 16.3% by MRI. The re-tear rate of massive tears was 50%. We investigated the details of the re-tears by MRI and arthroscopic findings. High re-tear rates were connected with cuff tear size and fatty degeneration of muscle belly. Cases with poor cuff quality in arthroscopically showed high re-tear rate. These results suggest that surgery operation should be performed as soon as possible after diagnosis of cuff tear to obtain good results. Cases with damage of long head of the biceps (LHB) are likely to develop impingement causes of re-tears. Some type of rehabilitation is required to avoid impingement in such cases. (author)

  4. Bulk and contact resistances of gas diffusion layers in proton exchange membrane fuel cells

    Science.gov (United States)

    Ye, Donghao; Gauthier, Eric; Benziger, Jay B.; Pan, Mu

    2014-06-01

    A multi-electrode probe is employed to distinguish the bulk and contact resistances of the catalyst layer (CL) and the gas diffusion layer (GDL) with the bipolar plate (BPP). Resistances are compared for Vulcan carbon catalyst layers (CL), carbon paper and carbon cloth GDL materials, and GDLs with microporous layers (MPL). The Vulcan carbon catalyst layer bulk resistance is 100 times greater than the bulk resistance of carbon paper GDL (Toray TG-H-120). Carbon cloth (CCWP) has bulk and contact resistances twice those of carbon paper. Compression of the GDL decreases the GDL contact resistance, but has little effect on the bulk resistance. Treatment of the GDL with polytetrafluoroethylene (PTFE) increases the contact resistance, but has little effect on the bulk resistance. A microporous layer (MPL) added to the GDL decreases the contact resistance, but has little effect on the bulk resistance. An equivalent circuit model shows that for channels less than 1 mm wide the contact resistance is the major source of electronic resistance and is about 10% of the total ohmic resistance associated with the membrane electrode assembly.

  5. Arthroscopic undersurface rotator cuff repair versus conventional arthroscopic double-row rotator cuff repair - Comparable results at 2-year follow-up.

    Science.gov (United States)

    Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng

    2018-01-01

    The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.

  6. Action potential propagation recorded from single axonal arbors using multi-electrode arrays.

    Science.gov (United States)

    Tovar, Kenneth R; Bridges, Daniel C; Wu, Bian; Randall, Connor; Audouard, Morgane; Jang, Jiwon; Hansma, Paul K; Kosik, Kenneth S

    2018-04-11

    We report the presence of co-occurring extracellular action potentials (eAPs) from cultured mouse hippocampal neurons among groups of planar electrodes on multi-electrode arrays (MEAs). The invariant sequences of eAPs among co-active electrode groups, repeated co-occurrences and short inter-electrode latencies are consistent with action potential propagation in unmyelinated axons. Repeated eAP co-detection by multiple electrodes was widespread in all our data records. Co-detection of eAPs confirms they result from the same neuron and allows these eAPs to be isolated from all other spikes independently of spike sorting algorithms. We averaged co-occurring events and revealed additional electrodes with eAPs that would otherwise be below detection threshold. We used these eAP cohorts to explore the temperature sensitivity of action potential propagation and the relationship between voltage-gated sodium channel density and propagation velocity. The sequence of eAPs among co-active electrodes 'fingerprints' neurons giving rise to these events and identifies them within neuronal ensembles. We used this property and the non-invasive nature of extracellular recording to monitor changes in excitability at multiple points in single axonal arbors simultaneously over several hours, demonstrating independence of axonal segments. Over several weeks, we recorded changes in inter-electrode propagation latencies and ongoing changes in excitability in different regions of single axonal arbors. Our work illustrates how repeated eAP co-occurrences can be used to extract physiological data from single axons with low electrode density MEAs. However, repeated eAP co-occurrences leads to over-sampling spikes from single neurons and thus can confound traditional spike-train analysis.

  7. All-carbon multi-electrode array for real-time in vitro measurements of oxidizable neurotransmitters

    Science.gov (United States)

    Picollo, Federico; Battiato, Alfio; Bernardi, Ettore; Plaitano, Marilena; Franchino, Claudio; Gosso, Sara; Pasquarelli, Alberto; Carbone, Emilio; Olivero, Paolo; Carabelli, Valentina

    2016-02-01

    We report on the ion beam fabrication of all-carbon multi electrode arrays (MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond (SCD) substrates. The fabricated SCD-MEAs are systematically employed for the in vitro simultaneous amperometric detection of the secretory activity from populations of chromaffin cells, demonstrating a new sensing approach with respect to standard techniques. The biochemical stability and biocompatibility of the SCD-based device combined with the parallel recording of multi-electrodes array allow: i) a significant time saving in data collection during drug screening and/or pharmacological tests over a large number of cells, ii) the possibility of comparing altered cell functionality among cell populations, and iii) the repeatition of acquisition runs over many cycles with a fully non-toxic and chemically robust bio-sensitive substrate.

  8. Cuff inflations do not affect night-time blood pressure

    DEFF Research Database (Denmark)

    Petersen, Emilie H; Theilade, Simone; Hansen, Tine W

    2015-01-01

    Discomfort related to cuff inflation may bias 24 h ambulatory blood pressure (BP) measurements, especially during night-time. We accessed the impact of cuff inflations by comparing 24 h BP recorded with a cuff-less tonometric wrist device and an upper-arm oscillometric cuff device. Fifty...

  9. Composition of Muscle Fiber Types in Rat Rotator Cuff Muscles.

    Science.gov (United States)

    Rui, Yongjun; Pan, Feng; Mi, Jingyi

    2016-10-01

    The rat is a suitable model to study human rotator cuff pathology owing to the similarities in morphological anatomy structure. However, few studies have reported the composition muscle fiber types of rotator cuff muscles in the rat. In this study, the myosin heavy chain (MyHC) isoforms were stained by immunofluorescence to show the muscle fiber types composition and distribution in rotator cuff muscles of the rat. It was found that rotator cuff muscles in the rat were of mixed fiber type composition. The majority of rotator cuff fibers labeled positively for MyHCII. Moreover, the rat rotator cuff muscles contained hybrid fibers. So, compared with human rotator cuff muscles composed partly of slow-twitch fibers, the majority of fast-twitch fibers in rat rotator cuff muscles should be considered when the rat model study focus on the pathological process of rotator cuff muscles after injury. Gaining greater insight into muscle fiber types in rotator cuff muscles of the rat may contribute to elucidate the mechanism of pathological change in rotator cuff muscles-related diseases. Anat Rec, 299:1397-1401, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  11. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  12. Passive contribution of the rotator cuff to abduction and joint stability.

    Science.gov (United States)

    Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola

    2011-11-01

    The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p non-functional cuff (p requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.

  13. Radiofrequency ablation of chondroblastoma using a multi-tined expandable electrode system: initial results

    International Nuclear Information System (INIS)

    Tins, Bernhard; Cassar-Pullicino, Victor; McCall, Iain; Cool, Paul; Williams, David; Mangham, David

    2006-01-01

    The standard treatment for chondroblastoma is surgery, which can be difficult and disabling due to its apo- or epiphyseal location. Radiofrequency (RF) ablation potentially offers a minimally invasive alternative. The often large size of chondroblastomas can make treatment with plain electrode systems difficult or impossible. This article describes the preliminary experience of RF treatment of chondroblastomas with a multi-tined expandable RF electrode system. Four cases of CT guided RF treatment are described. The tumour was successfully treated in all cases. In two cases, complications occurred; infraction of a subarticular chondroblastoma in one case and cartilage and bone damage in the unaffected compartment of a knee joint in the other. Radiofrequency treatment near a joint surface threatens the integrity of cartilage and therefore long-term joint function. In weight-bearing areas, the lack of bone replacement in successfully treated lesions contributes to the risk of mechanical failure. Multi-tined expandable electrode systems allow the treatment of large chondroblastomas. In weight-bearing joints and lesions near to the articular cartilage, there is a risk of cartilage damage and mechanical weakening of the bone. In lesions without these caveats, RF ablation appears promising. The potential risks and benefits need to be evaluated for each case individually. (orig.)

  14. Radiofrequency ablation of chondroblastoma using a multi-tined expandable electrode system: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Tins, Bernhard; Cassar-Pullicino, Victor; McCall, Iain [RJAH Orthopaedic and District Hospital, Department of Radiology, Oswestry (United Kingdom); Cool, Paul [RJAH Orthopaedic and District Hospital, Musculoskeletal Tumour Unit, Oswestry (United Kingdom); Williams, David [Hereford Hospital, Department of Orthopaedics, Hereford (United Kingdom); Mangham, David [RJAH Orthopaedic and District Hospital, Department of Pathology, Oswestry (United Kingdom)

    2006-04-15

    The standard treatment for chondroblastoma is surgery, which can be difficult and disabling due to its apo- or epiphyseal location. Radiofrequency (RF) ablation potentially offers a minimally invasive alternative. The often large size of chondroblastomas can make treatment with plain electrode systems difficult or impossible. This article describes the preliminary experience of RF treatment of chondroblastomas with a multi-tined expandable RF electrode system. Four cases of CT guided RF treatment are described. The tumour was successfully treated in all cases. In two cases, complications occurred; infraction of a subarticular chondroblastoma in one case and cartilage and bone damage in the unaffected compartment of a knee joint in the other. Radiofrequency treatment near a joint surface threatens the integrity of cartilage and therefore long-term joint function. In weight-bearing areas, the lack of bone replacement in successfully treated lesions contributes to the risk of mechanical failure. Multi-tined expandable electrode systems allow the treatment of large chondroblastomas. In weight-bearing joints and lesions near to the articular cartilage, there is a risk of cartilage damage and mechanical weakening of the bone. In lesions without these caveats, RF ablation appears promising. The potential risks and benefits need to be evaluated for each case individually. (orig.)

  15. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  16. Glenohumeral interposition of rotator cuff stumps: a rare complication of traumatic rotator cuff tear

    Directory of Open Access Journals (Sweden)

    Paulo Moraes Agnollitto

    2016-02-01

    Full Text Available Abstract The present report describes a case where typical findings of traumatic glenohumeral interposition of rotator cuff stumps were surgically confirmed. This condition is a rare complication of shoulder trauma. Generally, it occurs in high-energy trauma, frequently in association with glenohumeral joint dislocation. Radiography demonstrated increased joint space, internal rotation of the humerus and coracoid process fracture. In addition to the mentioned findings, magnetic resonance imaging showed massive rotator cuff tear with interposition of the supraspinatus, infraspinatus and subscapularis stumps within the glenohumeral joint. Surgical treatment was performed confirming the injury and the rotator cuff stumps interposition. It is important that radiologists and orthopedic surgeons become familiar with this entity which, because of its rarity, might be neglected in cases of shoulder trauma.

  17. The Relationship Between Shoulder Stiffness and Rotator Cuff Healing: A Study of 1,533 Consecutive Arthroscopic Rotator Cuff Repairs.

    Science.gov (United States)

    McNamara, William J; Lam, Patrick H; Murrell, George A C

    2016-11-16

    Retear and stiffness are not uncommon outcomes of rotator cuff repair. The purpose of this study was to evaluate the relationship between rotator cuff repair healing and shoulder stiffness. A total of 1,533 consecutive shoulders had an arthroscopic rotator cuff repair by a single surgeon. Patients assessed their shoulder stiffness using a Likert scale preoperatively and at 1, 6, 12, and 24 weeks (6 months) postoperatively, and examiners evaluated passive range of motion preoperatively and at 6, 12, and 24 weeks postoperatively. Repair integrity was determined by ultrasound evaluation at 6 months. After rotator cuff repair, there was an overall significant loss of patient-ranked and examiner-assessed shoulder motion at 6 weeks compared with preoperative measurements (p rotator cuff integrity at 6 months postoperatively (r = 0.11 to 0.18; p rotation at 6 weeks postoperatively was 7%, while the retear rate of patients with >20° of external rotation at 6 weeks was 15% (p rotator cuff repair was more likely to heal. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Supercapacitor electrodes by direct growth of multi-walled carbon nanotubes on Al: a study of performance versus layer growth evolution

    International Nuclear Information System (INIS)

    Zhao, Fu; Vicenzo, Antonello; Hashempour, Mazdak; Bestetti, Massimiliano

    2014-01-01

    Supercapacitor electrodes were fabricated by direct growth of multi-walled carbon nanotubes (CNTs) on Al current collectors via a chemical vapor deposition process in the presence of a spin-coated Co-Mo catalyst. A detailed study of the dependence of the CNT layer structure and thickness on growth time set the basis for the assessment of supercapacitors assembled with the CNTs/Al electrodes. As the main features of the layer growth evolution, an increase in the population of finer CNTs and a shift from a random entanglement to a rough vertical alignment of nanotubes were noted with proceeding growth. The growth time influence on the performance of supercapacitors was in fact apparent. Particularly, the specific capacitance of CNTs/Al electrodes in 0.5 M K 2 SO 4 aqueous electrolyte increased from 35 to 80 F g −1 as the CNT layer thickness varied from 20 to 60 μm, with a concurrent loss in rate capability (knee frequency from 1 kHz to 60 Hz). The latter was excellent in general, arguably due to both a fast ion transport through the interconnected CNT network and a negligible contribution of the active layer/current collector contact to the equivalent series resistance (0.15–0.22 mΩ g), a distinct advantage of the direct growth fabrication method. Overall, a relatively simple process of direct growth of CNTs on Al foils is shown to be an effective method to fabricate supercapacitor electrodes, notably in the absence of special measures and processing steps finalized to a tight control of nanotubes growth and organization

  19. Investigation of a Spinel-forming Cu-Mn Foam as an Oxygen Electrode Contact Material in a Solid Oxide Cell Single Repeating Unit

    DEFF Research Database (Denmark)

    Zielke, Philipp; Wulff, Anders Christian; Sun, Xiufu

    2017-01-01

    A critical issue in state-of-the-art solid oxide cell stacks is the contacting of the oxygen electrode. The commonly used ceramic contact layers are applied in a green state and cannot be sintered properly, due to compliance limitations arising from other stack components like sealing glasses...

  20. Effectiveness of MRI in rotator cuff injury

    International Nuclear Information System (INIS)

    Ohazama, Yuka

    1992-01-01

    To investigate the potential role of MR imaging in rotator cuf disorders, normal volunteers and patients with suspected rotator cuff injury were evaluated with a low field permanent magnet unit which had a wide gantry. MR findings of the patients were also compared with arthrography, subcromial bursography and operative findings. To establish optimal imaging technique and normal MR anatomy, 100 normal volunteers were examined. On proton density images, signal intensity of the rotator cuff tendon was low and homogenous, and that of rotator cuff muscles was intermediate. On T2 weighted images, signal intensity of muscles and tendon was decreased and that of joint effusion became brighter. In 38 patients with suspected rotator cuff injury, the signal intensity of the rotator cuff was increased to various degrees. In 21 of them, surgical correction was performed and 17 patients were followed with conservative treatment. MR imaging showed abnormalities in all 38 patients. Arthrography and bursography showed abnormalities in 28 out of 38 patients and 3 of 13 patients respectively. In 21 patients who underwent surgery, tear of the rotator cuff was confirmed, and discrepancies in MR and operative findings existed in 8 patients. In 2 patients, no tear was found in the other examinations, and it was suspected to be horizontal tear or degeneration in the substance of the muscle. MR imaging contributes to diagnosis and treatment planning in patients with suspected rotator cuff injury. (author)

  1. Complexity optimization and high-throughput low-latency hardware implementation of a multi-electrode spike-sorting algorithm.

    Science.gov (United States)

    Dragas, Jelena; Jackel, David; Hierlemann, Andreas; Franke, Felix

    2015-03-01

    Reliable real-time low-latency spike sorting with large data throughput is essential for studies of neural network dynamics and for brain-machine interfaces (BMIs), in which the stimulation of neural networks is based on the networks' most recent activity. However, the majority of existing multi-electrode spike-sorting algorithms are unsuited for processing high quantities of simultaneously recorded data. Recording from large neuronal networks using large high-density electrode sets (thousands of electrodes) imposes high demands on the data-processing hardware regarding computational complexity and data transmission bandwidth; this, in turn, entails demanding requirements in terms of chip area, memory resources and processing latency. This paper presents computational complexity optimization techniques, which facilitate the use of spike-sorting algorithms in large multi-electrode-based recording systems. The techniques are then applied to a previously published algorithm, on its own, unsuited for large electrode set recordings. Further, a real-time low-latency high-performance VLSI hardware architecture of the modified algorithm is presented, featuring a folded structure capable of processing the activity of hundreds of neurons simultaneously. The hardware is reconfigurable “on-the-fly” and adaptable to the nonstationarities of neuronal recordings. By transmitting exclusively spike time stamps and/or spike waveforms, its real-time processing offers the possibility of data bandwidth and data storage reduction.

  2. Volumetric evaluation of the rotator cuff musculature in massive rotator cuff tears with pseudoparalysis.

    Science.gov (United States)

    Rhee, Yong Girl; Cho, Nam Su; Song, Jong Hoon; Park, Jung Gwan; Kim, Tae Yong

    2017-09-01

    If the balance of the rotator cuff force couple is disrupted, pseudoparalysis may occur, but the exact mechanism remains unknown. This study investigated the effect of rotator cuff force couple disruption on active range of motion in massive rotator cuff tear (mRCT) by rotator cuff muscle volume analysis. The study included 53 patients with irreparable mRCT: 22 in the nonpseudoparalysis group and 31 in the pseudoparalysis group. The volumes of the subscapularis (SBS), infraspinatus (ISP), and teres minor (TM) muscles were measured using magnetic resonance imaging (MRI), and the ratios of each muscle volume to the anatomic external rotator (aER) volume were calculated. A control group of 25 individuals with normal rotator cuffs was included. Anterior-to-posterior cuff muscle volume ratio (SBS/ISP + TM) was imbalanced in both mRCT groups (1.383 nonpseudoparalysis and 1.302 pseudoparalysis). Between the 2 groups, the ISP/aER ratio (0.277 vs. 0.249) and the inferior SBS/aER ratio (0.426 vs. 0.390) were significantly decreased in the pseudoparalysis group (P= .022 and P= .040, respectively). However, neither the TM/aER ratio (0.357 vs. 0.376) nor the superior SBS/aER ratio (0.452 vs. 0.424) showed a significant difference between the two groups (P= .749 and P= .068, respectively). If the inferior SBS was torn, a high frequency of pseudoparalysis was noted (81.0%, P= .010). The disruption of transverse force couple was noted in both irreparable mRCT groups, although no significant difference was found between the nonpseudoparalysis and pseudoparalysis groups. ISP and inferior SBS muscle volumes showed a significant decrease in pseudoparalysis group and, therefore, were considered to greatly influence the loss of active motion in mRCT. The TM did not exert significant effect on the incidence of pseudoparalysis. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Rotator Cuff Repair in Adolescent Athletes.

    Science.gov (United States)

    Azzam, Michael G; Dugas, Jeffrey R; Andrews, James R; Goldstein, Samuel R; Emblom, Benton A; Cain, E Lyle

    2018-04-01

    Rotator cuff tears are rare injuries in adolescents but cause significant morbidity if unrecognized. Previous literature on rotator cuff repairs in adolescents is limited to small case series, with few data to guide treatment. Adolescent patients would have excellent functional outcome scores and return to the same level of sports participation after rotator cuff repair but would have some difficulty with returning to overhead sports. Case series; Level of evidence 4. A retrospective search of the practice's billing records identified all patients participating in at least 1 sport who underwent rotator cuff repair between 2006 and 2014 with an age Rotator Cuff Index. Thirty-two consecutive adolescent athletes (28 boys and 4 girls) with a mean age of 16.1 years (range, 13.2-17.9 years) met inclusion criteria. Twenty-nine patients (91%) had a traumatic event, and 27 of these patients (93%) had no symptoms before the trauma. The most common single tendon injury was to the supraspinatus (21 patients, 66%), of which 2 were complete tendon tears, 1 was a bony avulsion of the tendon, and 18 were high-grade partial tears. Fourteen patients (56%) underwent single-row repair of their rotator cuff tear, and 11 (44%) underwent double-row repair. All subscapularis injuries were repaired in open fashion, while all other tears were repaired arthroscopically. Twenty-seven patients (84%) completed the outcome questionnaires at a mean 6.2 years after surgery (range, 2-10 years). The mean ASES score was 93 (range, 65-100; SD = 9); mean Western Ontario Rotator Cuff Index, 89% (range, 60%-100%; SD = 13%); and mean numeric pain rating, 0.3 (range, 0-3; SD = 0.8). Overall, 25 patients (93%) returned to the same level of play or higher. Among overhead athletes, 13 (93%) were able to return to the same level of play, but 8 (57%) were forced to change positions. There were no surgical complications, but 2 patients did undergo a subsequent operation. Surgical repair of high-grade partial

  4. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.

    Science.gov (United States)

    Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C

    2014-05-01

    The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process

  5. Metal artefacts severely hamper magnetic resonance imaging of the rotator cuff tendons after rotator cuff repair with titanium suture anchors.

    Science.gov (United States)

    Schröder, Femke F; Huis In't Veld, Rianne; den Otter, Lydia A; van Raak, Sjoerd M; Ten Haken, Bennie; Vochteloo, Anne J H

    2018-04-01

    The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place. Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined. In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12). Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.

  6. Analysis of failed rotator cuff repair – Retrospective survey of revisions after open rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Rupert Schupfner

    2017-07-01

    Full Text Available Background Rotator cuff defects are frequently occurring shoulder pathologies associated with pain and movement impairment. Aims The aim of the study was to analyse the pathologies that lead to operative revisions after primary open rotator cuff repair. Methods In 216 patients who underwent primary rotator cuff repair and later required operative revision between 1996 to 2005, pathologies found intraoperatively during the primary operation and during revision surgery were collected, analysed and compared. Results The average age at the time of revision surgery was 54.3 years. The right shoulder (61.6 per cent was more often affected than the left, males (63.4 per cent more often than females. At primary operation – apart from rotator cuff repair – there were the following surgical procedures performed: 190 acromioplasty, 86 Acromiclavicular joint resections, 68 tenodesis, 40 adhesiolysis and 1 tenotomy. If an ACJ-resection had been performed in the primary operation, ACJ-problems were rare in revision surgery (p<0.01. Primary gleno-humeral adhesions were associated with a significant rise in re-tearing rate (p=0.049. Primary absence of adhesions went along with a significant lower rate of adhesions found at revision (p=0.018. Primary performed acromioplasty had no influence on re-tearing rate (p=0.408 or on the rate of subacromial impingement at revision surgery (p=0.709. Conclusion To avoid operative revision after rotator cuff repair relevant copathologies of the shoulder have to be identified before or during operation and treated accordingly. Therefore, even during open rotator cuff repair, the surgeon should initially start with arthroscopy of the shoulder joint and subacromial space to recognise co-pathologies.

  7. Arthroscintigraphy in suspected rotator cuff rupture

    International Nuclear Information System (INIS)

    Gratz, S.; Behr, T.; Becker, W.; Koester, G.; Vosshenrich, R.; Grabbe, E.

    1998-01-01

    Aim: In order to evaluate the diagnostic efficiency of arthroscintigraphy in suspected rotator cuff ruptures this new imaging procedure was performed 20 times in 17 patients with clinical signs of a rotator cuff lesion. The scintigraphic results were compared with sonography (n=20), contrast arthrography (n=20) and arthroscopy (n=10) of the shoulder joint. Methods: After performing a standard bone scintigraphy with intravenous application of 300 MBq 99m-Tc-methylene diphosphonate (MDP) for landmarking of the shoulder region arthroscintigraphy was performed after an intraarticular injection of 99m-Tc microcolloid (ALBU-RES 400 μCi/5 ml). The application was performed either in direct combination with contrast arthrography (n=10) or ultrasound conducted mixed with a local anesthetic (n=10). Findings at arthroscopical surgery (n=10) were used as the gold standard. Results: In case of complete rotator cuff rupture (n=5), arthroscintigraphy and radiographic arthrography were identical in 5/5. In one patient with advanced degenerative alterations of the shoulder joint radiographic arthrography incorrectly showed a complete rupture which was not seen by arthroscintigraphy and endoscopy. In 3 patients with incomplete rupture, 2/3 results were consistant. A difference was seen in one patient with a rotator cuff, that has been already revised in the past and that suffered of capsulitis and calcification. Conclusion: Arthroscinitgraphy is a sensitive technique for detection of rotator cuff ruptures. Because of the lower viscosity of the active compound, small ruptures can be easily detected, offering additional value over radiographic arthrography and ultrasound, especially for evaluation of incomplete cuff ruptures. (orig.) [de

  8. The concept of floating electrode for contact-less electrochemical measurements: Application to reinforcing steel-bar corrosion in concrete

    International Nuclear Information System (INIS)

    Keddam, M.; Novoa, X.R.; Vivier, V.

    2009-01-01

    The concept of floating electrode is introduced for defining the common electrochemical behaviour of any non-connected, electronically conducting, body immersed in an electrolytic medium. The emphasis is put on both its own polarisation features and its influence on the d.c. and a.c. current and potential across the cell, hence the feasibility, among others, of contact-less electrochemical measurements on floating electrodes. Application to reinforcing steel bars in concrete is investigated by numerical computation of the a.c. current and potential fields in a broad range of concrete resistivity, interfacial resistance and capacitance. Impedance defined in a 4-electrode configuration, when rationalised against the concrete resistivity, is shown to provide, within a realistic range of parameters, a practical mean to access the properties of the bar-concrete interface.

  9. Effect of tamoxifen on fatty degeneration and atrophy of rotator cuff muscles in chronic rotator cuff tear: An animal model study.

    Science.gov (United States)

    Cho, Edward; Zhang, Yue; Pruznak, Anne; Kim, H Mike

    2015-12-01

    Fatty degeneration of the rotator cuff muscles is an irreversible change resulting from chronic rotator cuff tear and is associated with poor clinical outcomes following rotator cuff repair. We evaluated the effect of Tamoxifen, a competitive estrogen receptor inhibitor, on fatty degeneration using a mouse model for chronic rotator cuff tear. Sixteen adult mice were divided into two diet groups (Tamoxifen vs. Regular) and subjected to surgical creation of a large rotator cuff tear and suprascapular nerve transection in their left shoulder with the right shoulder serving as a control. The rotator cuff muscles were harvested at 16 weeks and subjected to histology and RT-PCR for adipogenic and myogenic markers. Histology showed substantially decreased atrophy and endomysial inflammation in Tamoxifen group, but no significant differences in the amount of intramuscular adipocytes and lipid droplets compared to the Regular group. With RT-PCR, the operated shoulders showed significant upregulation of myogenin and PPAR-γ, and downregulation of myostatin compared to the nonsurgical shoulder. No significant differences of gene expression were found between the two diet groups. Our study demonstrated that tamoxifen diet leads to decreased muscle atrophy and inflammatory changes following chronic rotator cuff tear, but has no apparent effect on adipogenesis. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Boundary element numerical method for the electric field generated by oblique multi-needle electrodes

    Institute of Scientific and Technical Information of China (English)

    LIU FuPing; WANG AnLing; WANG AnXuan; CAO YueZu; CHEN Qiang; YANG ChangChun

    2009-01-01

    According to the electric potential of oblique multi-needle electrodes (OMNE) in biological tissue, the discrete equations based on the indetermination linear current density were established by the boundary element integral equations (BEIE). The non-uniform distribution of the current flowing from multi-needle electrodes to conductive biological tissues was imaged by solving a set of linear equa-tions. Then, the electric field and potential generated by OMNE in biological tissues at any point may be determined through the boundary element method (BEM). The time of program running and stability of computing method are examined by an example. It demonstrates that the algorithm possesses a quick speed and the steady computed results. It means that this method has an important referenced significance for computing the field and the potential generated by OMNE in bio-tissue, which is a fast, effective and accurate computing method.

  11. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    Science.gov (United States)

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  12. Solder free joining as a highly effective method for making contact between thermoelectric materials and metallic electrodes

    DEFF Research Database (Denmark)

    Malik, Safdar Abbas; Le, Thanh Hung; Van Nong, Ngo

    2017-01-01

    /react with both Ag and Ni electrodes, and penetrate into ZnSb legs. SEM-EDX analysis recorded a significant excess of Zn in the ZnSb leg after joining. We found that, using microlayers of Ti and Cr as interconnecting agent, a very good interfacial contact was obtained, and the starting composition of ZnSb legs...

  13. Recurrent rotator cuff tear: is ultrasound imaging reliable?

    Science.gov (United States)

    Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer

    2018-02-02

    The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients.

    Science.gov (United States)

    Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel

    2007-10-01

    Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (Pblood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

  15. Sub-discretized surface model with application to contact mechanics in multi-body simulation

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S; Williams, J

    2008-02-28

    The mechanics of contact between rough and imperfectly spherical adhesive powder grains are often complicated by a variety of factors, including several which vary over sub-grain length scales. These include several traction factors that vary spatially over the surface of the individual grains, including high energy electron and acceptor sites (electrostatic), hydrophobic and hydrophilic sites (electrostatic and capillary), surface energy (general adhesion), geometry (van der Waals and mechanical), and elasto-plastic deformation (mechanical). For mechanical deformation and reaction, coupled motions, such as twisting with bending and sliding, as well as surface roughness add an asymmetry to the contact force which invalidates assumptions for popular models of contact, such as the Hertzian and its derivatives, for the non-adhesive case, and the JKR and DMT models for adhesive contacts. Though several contact laws have been offered to ameliorate these drawbacks, they are often constrained to particular loading paths (most often normal loading) and are relatively complicated for computational implementation. This paper offers a simple and general computational method for augmenting contact law predictions in multi-body simulations through characterization of the contact surfaces using a hierarchically-defined surface sub-discretization. For the case of adhesive contact between powder grains in low stress regimes, this technique can allow a variety of existing contact laws to be resolved across scales, allowing for moments and torques about the contact area as well as normal and tangential tractions to be resolved. This is especially useful for multi-body simulation applications where the modeler desires statistical distributions and calibration for parameters in contact laws commonly used for resolving near-surface contact mechanics. The approach is verified against analytical results for the case of rough, elastic spheres.

  16. Evaluation of Repair Tension in Arthroscopic Rotator Cuff Repair: Does It Really Matter to the Integrity of the Rotator Cuff?

    Science.gov (United States)

    Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon

    2016-11-01

    Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016

  17. Electrochemical parameters of ethamsylate at multi-walled carbon nanotube modified glassy carbon electrodes.

    Science.gov (United States)

    Wang, Sheng-Fu; Xu, Qiao

    2007-05-01

    In this paper, some electrochemical parameters of ethamsylate at a multi-walled carbon nanotube modified glassy carbon electrode, such as the charge number, exchange current density, standard heterogeneous rate constant and diffusion coefficient, were measured by cyclic voltammetry, chronoamperometry and chronocoulometry. The modified electrode exhibits good promotion of the electrochemical reaction of ethamsylate and increases the standard heterogeneous rate constant of ethamsylate greatly. The differential pulse voltammetry responses of ethamsylate were linearly dependent on its concentrations in a range from 2.0 x 10(-6) to 6.0 x 10(-5) mol L(-1), with a detection limit of 4.0 x 10(-7) mol L(-1).

  18. Development and Characterization of a Diamond-Insulated Graphitic Multi Electrode Array Realized with Ion Beam Lithography

    Directory of Open Access Journals (Sweden)

    Federico Picollo

    2014-12-01

    Full Text Available The detection of quantal exocytic events from neurons and neuroendocrine cells is a challenging task in neuroscience. One of the most promising platforms for the development of a new generation of biosensors is diamond, due to its biocompatibility, transparency and chemical inertness. Moreover, the electrical properties of diamond can be turned from a perfect insulator into a conductive material (resistivity ~mΩ·cm by exploiting the metastable nature of this allotropic form of carbon. A 16‑channels MEA (Multi Electrode Array suitable for cell culture growing has been fabricated by means of ion implantation. A focused 1.2 MeV He+ beam was scanned on a IIa single-crystal diamond sample (4.5 × 4.5 × 0.5 mm3 to cause highly damaged sub-superficial structures that were defined with micrometric spatial resolution. After implantation, the sample was annealed. This process provides the conversion of the sub-superficial highly damaged regions to a graphitic phase embedded in a highly insulating diamond matrix. Thanks to a three-dimensional masking technique, the endpoints of the sub-superficial channels emerge in contact with the sample surface, therefore being available as sensing electrodes. Cyclic voltammetry and amperometry measurements of solutions with increasing concentrations of adrenaline were performed to characterize the biosensor sensitivity. The reported results demonstrate that this new type of biosensor is suitable for in vitro detection of catecholamine release.

  19. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  20. Superior glenoid inclination and rotator cuff tears.

    Science.gov (United States)

    Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z

    2018-03-23

    The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Disposable screen-printed bismuth electrode modified with multi-walled carbon nanotubes for electrochemical stripping measurements.

    Science.gov (United States)

    Niu, Xiangheng; Zhao, Hongli; Lan, Minbo

    2011-01-01

    Integrating the advantages of screen printing technology with the encouraging electroanalytical characteristic of metallic bismuth, we developed an ultrasensitive and disposable screen-printed bismuth electrode (SPBE) modified with multi-walled carbon nanotubes (MWCNTs) for electrochemical stripping measurements. Metallic bismuth powders and MWCNTs were homogeneously mixed with graphite-carbon ink to mass-prepare screen-printed bismuth electrode doped with multi-walled carbon nanotubes (SPBE/MWCNT). The electroanalytical performance of the prepared SPBE/MWCNT was intensively evaluated by measuring trace Hg(II) with square-wave anodic stripping voltammetry (SWASV). The results indicated that the SPBE modified with 2 wt% MWCNTs could offer a more sensitive response to trace Hg(II) than the bare SPBE. The stripping current obtained at SPBE/MWCNT was linear with Hg(II) concentration in the range from 0.2 to 40 µg/L (R(2) = 0.9976), with a detection limit of 0.09 µg/L (S/N = 3) under 180 s accumulation. The proposed "mercury-free" electrode, with extremely simple preparation and ultrahigh sensitivity, holds wide application prospects in both environmental and industrial monitoring. 2011 © The Japan Society for Analytical Chemistry

  2. The Repaired Rotator Cuff: MRI and Ultrasound Evaluation.

    Science.gov (United States)

    Lee, Susan C; Williams, Danielle; Endo, Yoshimi

    2018-03-01

    The purposes of this review were to provide an overview of the current practice of evaluating the postoperative rotator cuff on imaging and to review the salient imaging findings of the normal and abnormal postoperative rotator cuff, as well as of postoperative complications. The repaired rotator cuff frequently appears abnormal on magnetic resonance imaging (MRI) and ultrasound (US). Recent studies have shown that while the tendons typically normalize, they can demonstrate clinically insignificant abnormal imaging appearances for longer than 6 months. Features of capsular thickening or subacromial-subdeltoid bursal thickening and fluid distension were found to decrease substantially in the first 6-month postoperative period. MRI and US were found to be highly comparable in the postoperative assessment of the rotator cuff, although they had a lower sensitivity for partial thickness tears. Imaging evaluation of newer techniques such as patch augmentation and superior capsular reconstruction needs to be further investigated. MRI and US are useful in the postoperative assessment of the rotator cuff, not only for evaluation of the integrity of the rotator cuff, but also for detecting hardware complications and other etiologies of shoulder pain.

  3. Suprascapular Nerve: Is It Important in Cuff Pathology?

    Directory of Open Access Journals (Sweden)

    Lewis L. Shi

    2012-01-01

    Full Text Available Suprascapular nerve and rotator cuff function are intimately connected. The incidence of suprascapular neuropathy has been increasing due to improved understanding of the disease entity and detection methods. The nerve dysfunction often results from a traction injury or compression, and a common cause is increased tension on the nerve from retracted rotator cuff tears. Suprascapular neuropathy should be considered as a diagnosis if patients exhibit posterosuperior shoulder pain, atrophy or weakness of supraspinatus and infraspinatus without rotator cuff tear, or massive rotator cuff with retraction. Magnetic resonance imaging and electromyography studies are indicated to evaluate the rotator cuff and function of the nerve. Fluoroscopically guided injections to the suprascapular notch can also be considered as a diagnostic option. Nonoperative treatment of suprascapular neuropathy can be successful, but in the recent decade there is increasing evidence espousing the success of surgical treatment, in particular arthroscopic suprascapular nerve decompression. There is often reliable improvement in shoulder pain, but muscle atrophy recovery is less predictable. More clinical data are needed to determine the role of rotator cuff repair and nerve decompression in the same setting.

  4. Assessment and treatment strategies for rotator cuff tears

    Science.gov (United States)

    Al-Hakim, Wisam; Noorani, Ali

    2014-01-01

    Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960

  5. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  6. Knotless double-row SutureBridge rotator cuff repairs have improved self-reinforcement compared with double-row SutureBridge repairs with tied medial knots: a biomechanical study using an ovine model.

    Science.gov (United States)

    Smith, Geoffrey C S; Bouwmeester, Theresia M; Lam, Patrick H

    2017-12-01

    In double-row SutureBridge (Arthrex, Naples, FL, USA) rotator cuff repairs, increasing tendon load may generate progressively greater compression forces at the repair footprint (self-reinforcement). SutureBridge rotator cuff repairs using tied horizontal mattress sutures medially may limit this effect compared with a knotless construct. Rotator cuff repairs were performed in 9 pairs of ovine shoulders. One group underwent repair with a double-row SutureBridge construct with tied horizontal medial-row mattress sutures. The other group underwent repair in an identical fashion except that medial-row knots were not tied. Footprint contact pressure was measured at 0° and 20° of abduction under loads of 0 to 60 N. Pull-to-failure tests were then performed. In both repair constructs, each 10-N increase in rotator cuff tensile load led to a significant increase in footprint contact pressure (P row SutureBridge configuration, self-reinforcement is seen in repairs with and without medial-row knots. Self-reinforcement is greater with the knotless technique. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    Science.gov (United States)

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  8. LB03.04: SPHYGMOMANOMETER CUFF CONSTRUCTION AND MATERIALS AFFECT TRANSMISSION OF PRESSURE FROM CUFF TO ARTERIAL WALL. FINITE ELEMENT ANALYSIS OF HUMAN PRESSURE MEASUREMENTS AND DICOM DATA.

    Science.gov (United States)

    Lewis, P; Naqvi, S; Mandal, P; Potluri, P

    2015-06-01

    Sphygmomanometer cuff pressure during deflation is assumed to equal systolic arterial pressure at the point of resumption of flow. Previous studies demonstrated that pressure decreases with increasing depth of soft tissues whilst visco-elastic characteristics of the arm tissue cause spatial and temporal variation in pressure magnitude. These generally used non-anatomical axisymmetrical arm simulations without incorporating arterial pressure variation. We used data from a volunteer's Magnetic Resonance (MR) arm scan and investigated the effect of variations in cuff materials and construction on the simulated transmission of pressure from under the cuff to the arterial wall under sinusoidal flow conditions. Pressure was measured under 8 different cuffs using Oxford Pressure Monitor Sensors placed at 90 degrees around the mid upper arm of a healthy male. Each cuff was inflated 3 times to 155 mmHg and then deflated to zero with 90 seconds between inflations. Young's modulus, flexural rigidity and thickness of each cuff was measured.Using DICOM data from the MR scan of the arm, a 3D model was derived using ScanIP and imported into Abaqus for Finite Element Analysis (FEA). Published mechanical properties of arm tissues and geometric non-linearity were assumed. The measured sub-cuff pressures were applied to the simulated arm and pressure was calculated around the brachial arterial wall. which was loaded with a sinusoidal pressure of 125/85 mmHg. FEA estimates of pressure around the brachial artery cuffs varied by up to 27 mmHg SBP and 17 mmHg DBP with different cuffs. Pressures within the cuffs varied up to 27 mmHg. Pressure transmission from the cuff to the arterial surface achieved a 95% transmission ratio with one rubber-bladdered cuff but varied between 76 and 88% for the others. Non-uniform pressure distribution around the arterial wall was strongly related to cuff fabric elastic modulus. Identical size cuffs with a separate rubber bladder produced peri

  9. Will Preoperative Atrophy and Fatty Degeneration of the Shoulder Muscles Improve after Rotator Cuff Repair in Patients with Massive Rotator Cuff Tears?

    Directory of Open Access Journals (Sweden)

    Hiroshi Yamaguchi

    2012-01-01

    Full Text Available Recently, retear rate after repair for massive cuff tear have been improved through devised suture techniques. However, reported retear rate is relevant to preoperative atrophy and fatty degeneration. The purpose of this study was to investigate whether preoperative atrophy and fatty degeneration of rotator cuff muscles improve by successful repair. Twenty-four patients with massive rotator cuff tear were evaluated on the recovery of atrophy and fatty degeneration of supraspinatus and infraspinatus muscle after surgery. Atrophy was classified by the occupation ratio and fatty degeneration by modified Goutallier's classification. Both were assessed on magnetic resonance imaging (MRI before and after the operation. When the cuff was well repaired, improvement of the atrophy and fatty degeneration were observed in a half and a one-fourth of the cases, respectively. In retear cases, however, atrophy and fatty degeneration became worse. Improvement of atrophy and fatty degeneration of the rotator cuff muscles may be expected in the cases with successful achievement of rotator cuff repair for large and massive tear.

  10. Electrochemistry of metoclopramide at multi-walled carbon nanotube modified electrode and its voltammetric detection.

    Science.gov (United States)

    Guo, Wei; Geng, Mingjiang; Zhou, Lingyun

    2012-01-01

    A simple, sensitive and inexpensive electrochemical method was developed for the determination of metoclopramide (MCP) with a multi-wall carbon nanotube (MWNT) modified glassy carbon electrode (GCE). MWNT was dispersed into polyacrylic acid (PAA); the aqueous suspension was then cast on GCE electrodes, forming MWNT-PAA films after evaporation of the solvent. The electrochemical behavior of MCP at the MWNT-modified electrode was investigated in detail. Compared with the bare GCE, the MWNT-modified electrode exhibits electrocatalytic activity to the oxidation of MCP because of the significant oxidation peak-current enhancement. Furthermore, various experimental parameters, such as the solution pH value, the amount of MWNT-PAA suspension and accumulation conditions were optimized for the determination of MCP. Based on the electrocatalytic effect of the MWNT-modified electrode, linear sweep voltammetry (LSV) was developed for the determination of MCP with the linear response in the range from 1.0 × 10(-7) to 1.0 × 10(-5) mol L(-1) and a detection limit of 5.0 × 10(-8) mol L(-1). The method has been successfully applied to the determination of MCP in commercial MCP tablets.

  11. Degenerative full thickness rotator cuff tears : Towards optimal management

    NARCIS (Netherlands)

    Lambers Heerspink, Frederik

    2016-01-01

    The shoulder is one of the most complex joints in the body. Besides a wide range of motion it also has to be stable. The rotator cuff is a major stabiliser of the glenohumoral joint. With increasing age rotator cuff tears are common. Successful treatment is described following surgical (rotator cuff

  12. Catoptric electrodes: transparent metal electrodes using shaped surfaces.

    Science.gov (United States)

    Kik, Pieter G

    2014-09-01

    An optical electrode design is presented that theoretically allows 100% optical transmission through an interdigitated metallic electrode at 50% metal areal coverage. This is achieved by redirection of light incident on embedded metal electrode lines to an angle beyond that required for total internal reflection. Full-field electromagnetic simulations using realistic material parameters demonstrate 84% frequency-averaged transmission for unpolarized illumination across the entire visible spectral range using a silver interdigitated electrode at 50% areal coverage. The redirection is achieved through specular reflection, making it nonresonant and arbitrarily broadband, provided the electrode width exceeds the optical wavelength. These findings could significantly improve the performance of photovoltaic devices and optical detectors that require high-conductivity top contacts.

  13. Transformation of medical grade silicone rubber under Nd:YAG and excimer laser irradiation: First step towards a new miniaturized nerve electrode fabrication process

    International Nuclear Information System (INIS)

    Dupas-Bruzek, C.; Robbe, O.; Addad, A.; Turrell, S.; Derozier, D.

    2009-01-01

    Medical grade silicone rubber, poly-dimethylsiloxane (PDMS) is a widely used biomaterial. Like for many polymers, its surface can be modified in order to change one or several of its properties which further allow this surface to be functionalized. Laser-induced surface modification of PDMS under ambient conditions is an easy and powerful method for the surface modification of PDMS without altering its bulk properties. In particular, we profit from both UV laser inducing surface modification and of UV laser micromachining to develop a first part of a new process aiming at increasing the number of contacts and tracks within the same electrode surface to improve the nerve selectivity of implantable self sizing spiral cuff electrodes. The second and last part of the process is to further immerse the engraved electrode in an autocatalytic Pt bath leading in a selective Pt metallization of the laser irradiated tracks and contacts and thus to a functionalized PDMS surface. In the present work, we describe the different physical and chemical transformations of a medical grade PDMS as a function of the UV laser and of the irradiation conditions used. We show that the ablation depths, chemical composition, structure and morphology vary with (i) the laser wavelength (using an excimer laser at 248 nm and a frequency-quadrupled Nd:YAG laser at 266 nm), (ii) the conditions of irradiation and (iii) the pulse duration. These different modified properties are expected to have a strong influence on the nucleation and growth rates of platinum which govern the adhesion and the thickness of the Pt layer on the electrodes and thus the DC resistance of tracks.

  14. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  15. Light-addressable amperometric electrodes for enzyme sensors based on direct quantum dot-electrode contacts

    Science.gov (United States)

    Riedel, M.; Göbel, G.; Parak, W. J.; Lisdat, F.

    2014-03-01

    Quantum dots allow the generation of charge carriers upon illumination. When these particles are attached to an electrode a photocurrent can be generated. This allows their use as a light-switchable layer on the surface. The QDs can not only exchange electronics with the electrode, but can also interact with donor or acceptor compounds in solution providing access to the construction of signal chains starting from an analytic molecule. The magnitude and the direction of the photocurrent depend on several factors such as electrode polarization, solution pH and composition. These defined dependencies have been evaluated with respect to the combination of QD-electrodes with enzyme reactions for sensorial purpose. CdSe/ZnS-QD-modified electrodes can be used to follow enzymatic reactions in solution based on the oxygen sensitivity. In order to develop a photoelectrochemical biosensor, e.g. glucose oxidase is immobilized on the CdSe/ZnS-electrode. One immobilization strategy applies the layer-by-layer-technique of GOD and a polyelectrolyte. Photocurrent measurements of such a sensor show a clear concentration dependent behavior. The principle of combing QD oxidase. The sensitivity of quantum dot electrodes can be influenced by additional nanoparticles, but also by multiple layers of the QDs. In another direction of research it can be influenced by additional nanoparticles, but also by multiple layers of the QDs. In another direction of research it can be demonstrated that direct electron transfer from excited quantum dots can be achieved with the redox protein cytochrome c. This allows the detection of the protein, but also interaction partners such as a enzymes or superoxide.

  16. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  17. Systematics of injuries of the rotator cuff and biceps tendon

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Pones, M.; Breitenseher, J.B.

    2015-01-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [de

  18. Low resistivity contacts to YBa2Cu3O(7-x) superconductors

    Science.gov (United States)

    Hsi, Chi-Shiung; Haertling, Gene H.

    1991-01-01

    Silver, gold, platinum, and palladium metals were investigated as electroding materials for the YBa2Cu3O(7-x) superconductors. Painting, embedding, and melting techniques were used to apply the electrodes. Contact resistivities were determined by: (1) type of electrode; (2) firing conditions; and (3) application method. Electrodes fired for long times exhibited lower contact resistivities than those fired for short times. Low-resistivity contacts were found for silver and gold electrodes. Silver, which made good ohmic contact to the YBa2Cu3O(7-x) superconductor with low contact resistivities was found to be the best electroding material among the materials evaluated in this investigation.

  19. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  20. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  1. Transfer characteristics and contact resistance in Ni- and Ti-contacted graphene-based field-effect transistors

    International Nuclear Information System (INIS)

    Di Bartolomeo, A; Giubileo, F; Iemmo, L; Romeo, F; Santandrea, S; Gambardella, U

    2013-01-01

    We produced graphene-based field-effect transistors by contacting mono- and bi-layer graphene by sputtering Ni or Ti as metal electrodes. We performed electrical characterization of the devices by measuring their transfer and output characteristics. We clearly observed the presence of a double-dip feature in the conductance curve for Ni-contacted transistors, and we explain it in terms of charge transfer and graphene doping under the metal contacts. We also studied the contact resistance between the graphene and the metal electrodes with larger values of ∼30 kΩμm 2 recorded for Ti contacts. Importantly, we prove that the contact resistance is modulated by the back-gate voltage. (paper)

  2. Forces in Liquid Metal Contacts

    DEFF Research Database (Denmark)

    Duggen, Lars; Mátéfi-Tempfli, Stefan

    2014-01-01

    Using rather well known theory about capillary bridges between two electrodes we calculate the tensile force that can be applied to liquid metal contacts in the micrometer regime. Assuming circular symmetry, full wetting of the electrodes, and neglecting gravity, we present a brief review of the ...... of the necessary theory and find numerically the forces to be in the 100μN range for liquid metals as mercury and liquid Gallium suspended between electrodes of 20μm radius.......Using rather well known theory about capillary bridges between two electrodes we calculate the tensile force that can be applied to liquid metal contacts in the micrometer regime. Assuming circular symmetry, full wetting of the electrodes, and neglecting gravity, we present a brief review...

  3. Safety of atrial fibrillation ablation with novel multi-electrode array catheters on uninterrupted anticoagulation-a single-center experience.

    LENUS (Irish Health Repository)

    Hayes, Christopher Ruslan

    2012-02-01

    INTRODUCTION: A recent single-center report indicated that the performance of atrial fibrillation ablation in patients on uninterrupted warfarin using a conventional deflectable tip electrode ablation catheter may be as safe as periprocedural discontinuation of warfarin and bridging with heparin. Novel multi-electrode array catheters for atrial fibrillation ablation are currently undergoing clinical evaluation. While offering the possibility of more rapid atrial fibrillation ablation, they are stiffer and necessitate the deployment of larger deflectable transseptal sheaths, and it remains to be determined if they increase the risk of cardiac perforation and vascular injury. Such potential risks would have implications for a strategy of uninterrupted periprocedural anticoagulation. METHOD AND RESULTS: We audited the safety outcomes of our atrial fibrillation ablation procedures using multi-electrode array ablation catheters in patients on uninterrupted warfarin (CHADS2 score>or=2) and in patients not on warfarin (uninterrupted aspirin). Two bleeding complications occurred in 49 patients on uninterrupted warfarin, both of which were managed successfully without longterm sequelae, and no bleeding complication occurred in 32 patients not on warfarin (uninterrupted aspirin). There were no thromboembolic events or other complication with either anticoagulant regimen. CONCLUSION: Despite the larger diameter and increased stiffness of multi-electrode array catheters and their deflectable transseptal sheaths, their use for catheter ablation in patients with atrial fibrillation on uninterrupted warfarin in this single-center experience does not appear to be unsafe, and thus, an adequately powered multicenter prospective randomized controlled trial should be considered.

  4. Analytical application of solid contact ion-selective electrodes for determination of copper and nitrate in various food products and drinking water.

    Science.gov (United States)

    Wardak, Cecylia; Grabarczyk, Malgorzata

    2016-08-02

    A simple, fast and cheap method for monitoring copper and nitrate in drinking water and food products using newly developed solid contact ion-selective electrodes is proposed. Determination of copper and nitrate was performed by application of multiple standard additions technique. The reliability of the obtained results was assessed by comparing them using the anodic stripping voltammetry or spectrophotometry for the same samples. In each case, satisfactory agreement of the results was obtained, which confirms the analytical usefulness of the constructed electrodes.

  5. An all-solid-state screen-printed carbon paste reference electrode based on poly(3,4-ethylenedioxythiophene) as solid contact transducer

    International Nuclear Information System (INIS)

    Xu, Hui; Pan, Yiwen; Chen, Ying; Ye, Ying; Wang, You; Li, Guang

    2012-01-01

    The paper presents the design of an all-solid-state portable reference electrode based on a screen-printed carbon paste electrode suitable for rapid human serum testing. The electrode was covered by electropolymerized poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrenesulfonate) (PSS) as an internal solid contact layer and polyvinyl chloride (PVC) membrane containing lipophilic anion and cation additives. The electrochemical properties of PEDOT(PSS) and PEDOT(PSS)/PVC film on a carbon paste electrode were studied by electrochemical impedance spectroscopy and cyclic voltammetry methods. The reference electrode exhibited good potential stability (for H + , Na + , K + , Ca 2+ , Cl − and CO 2− 3 /HCO − 3 ), good reproducibility and long-term stability. The structure is applied as reference electrodes in human serum pH analysis with pH ion selective planar electrodes, forming a serum pH sensor. The response time of such a pH sensor was 15 s and the sensitivity was −52.2 ± 1.0 mV per decade. Other properties, such as repeatability, reproducibility and stability, were also evaluated. Clinical trials were carried out and compared with the results obtained from the routine hospital electrolyte analyzer, which demonstrated that their analytical performance was closely matched. (paper)

  6. A complicated biocomputing system based on multi-responsive P(NIPAM-co-APBA) copolymer film electrodes and electrocatalysis of NADH.

    Science.gov (United States)

    Liang, Jiying; Yu, Xue; Yang, Tiangang; Li, Menglu; Shen, Li; Jin, Yue; Liu, Hongyun

    2017-08-23

    In this paper, poly(N-isopropylacrylamide-co-3-aminophenylboronic acid) (P(NIPAM-co-APBA)) copolymer films were successfully electropolymerized on the Au electrode surface. The electroactive probe ferrocene carboxylic acid (FCA) in solution showed reversible thermal-, glucose- and pH-responsive on-off cyclic voltammetric (CV) behaviors at the film electrodes. The comparative experiments demonstrated that the thermo-responsive property of the film electrode was ascribed to the PNIPAM component of the films, whereas the glucose- and pH-sensitive behaviors came from the PAPBA constituent. The reduced form of nicotinamide adenine dinucleotide (NADH) could be electrocatalytically oxidized by FCA at the film electrodes, which would greatly amplify the multi-responsive CV signal difference between the on and off states. On the basis of these results, a binary 4-input/4-output logic circuit was fabricated with temperature, glucose, pH and NADH as inputs and the CV responses at 4 different levels as outputs. Moreover, a ternary CONSENSUS logic circuit was established on the same platform, which was the first report on the combination of ternary logic gate and bioelectrocatalysis without using enzymes. This work provided a novel idea for constructing complicated biocomputing systems by increasing the number of inputs/outputs with multi-sensitive interfaces and by designing new types of multi-valued logic gates on the basis of bioelectrocatalysis.

  7. Impingement syndrome and rotator cuff tears: US findings in 140 patients

    International Nuclear Information System (INIS)

    Malvestiti, Oreste; Scorsolini, Alessandro; Ratti, Francesco; Ferraris, Giuseppe; Columbaro, Guido; Mariani, Claudio

    1997-01-01

    The authors investigated the role of rotator cuff impingement in causing tears of supraspinatus and biceps tendons and the comparative reliability of plain radiography and sonography (US). One hundred forty patients with symtoms referrable to the rotator cuff were examined with plain radiography and US of the shoulder. The differential diagnosis must distinguish all these common causes of shoulder dysfunction and cuff problems from other conditions. The authors conclude that US and plain radiography are accurate routine tests of rotator cuff integrity and rotator cuff impingement

  8. Controlled assembly of multi-segment nanowires by histidine-tagged peptides

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Aijun A; Lee, Joun; Jenikova, Gabriela; Mulchandani, Ashok; Myung, Nosang V; Chen, Wilfred [Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521 (United States)

    2006-07-28

    A facile technique was demonstrated for the controlled assembly and alignment of multi-segment nanowires using bioengineered polypeptides. An elastin-like-polypeptide (ELP)-based biopolymer consisting of a hexahistine cluster at each end (His{sub 6}-ELP-His{sub 6}) was generated and purified by taking advantage of the reversible phase transition property of ELP. The affinity between the His{sub 6} domain of biopolymers and the nickel segment of multi-segment nickel/gold/nickel nanowires was exploited for the directed assembly of nanowires onto peptide-functionalized electrode surfaces. The presence of the ferromagnetic nickel segments on the nanowires allowed the control of directionality by an external magnetic field. Using this method, the directed assembly and positioning of multi-segment nanowires across two microfabricated nickel electrodes in a controlled manner was accomplished with the expected ohmic contact.

  9. Rotator cuff repair using cell sheets derived from human rotator cuff in a rat model.

    Science.gov (United States)

    Harada, Yoshifumi; Mifune, Yutaka; Inui, Atsuyuki; Sakata, Ryosuke; Muto, Tomoyuki; Takase, Fumiaki; Ueda, Yasuhiro; Kataoka, Takeshi; Kokubu, Takeshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2017-02-01

    To achieve biological regeneration of tendon-bone junctions, cell sheets of human rotator-cuff derived cells were used in a rat rotator cuff injury model. Human rotator-cuff derived cells were isolated, and cell sheets were made using temperature-responsive culture plates. Infraspinatus tendons in immunodeficient rats were resected bilaterally at the enthesis. In right shoulders, infraspinatus tendons were repaired by the transosseous method and covered with the cell sheet (sheet group), whereas the left infraspinatus tendons were repaired in the same way without the cell sheet (control group). Histological examinations (safranin-O and fast green staining, isolectin B4, type II collagen, and human-specific CD31) and mRNA expression (vascular endothelial growth factor; VEGF, type II collagen; Col2, and tenomodulin; TeM) were analyzed 4 weeks after surgery. Biomechanical tests were performed at 8 weeks. In the sheet group, proteoglycan at the enthesis with more type II collagen and isolectin B4 positive cells were seen compared with in the control group. Human specific CD31-positive cells were detected only in the sheet group. VEGF and Col2 gene expressions were higher and TeM gene expression was lower in the sheet group than in the control group. In mechanical testing, the sheet group showed a significantly higher ultimate failure load than the control group at 8 weeks. Our results indicated that the rotator-cuff derived cell sheet could promote cartilage regeneration and angiogenesis at the enthesis, with superior mechanical strength compared with the control. Treatment for rotator cuff injury using cell sheets could be a promising strategy for enthesis of tendon tissue engineering. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:289-296, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Diagnostic imaging of shoulder rotator cuff lesions

    Directory of Open Access Journals (Sweden)

    Nogueira-Barbosa Marcello Henrique

    2002-01-01

    Full Text Available Shoulder rotator cuff tendon tears were evaluated with ultrasonography (US and magnetic resonance imaging (MRI. Surgical or arthroscopical correlation were available in 25 cases. Overall costs were also considered. Shoulder impingement syndrome diagnosis was done on a clinical basis. Surgery or arthroscopy was considered when conservative treatment failure for 6 months, or when rotator cuff repair was indicated. Ultrasound was performed in 22 patients and MRI in 17 of the 25 patients. Sensitivity, specificity and accuracy were 80%, 100% and 90.9% for US and 90%, 100% and 94.12% for MRI, respectively. In 16 cases both US and MRI were obtained and in this subgroup statistical correlation was excellent (p< 0.001. We concluded that both methods are reliable for rotator cuff full thickness tear evaluation. Since US is less expensive, it could be considered as the screening method when rotator cuff integrity is the main question, and when well trained radiologists and high resolution equipment are available.

  11. Biomaterials based strategies for rotator cuff repair.

    Science.gov (United States)

    Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin

    2017-09-01

    Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Electrodes of carbonized MWCNT-cellulose paper for supercapacitor

    Science.gov (United States)

    Sun, Xiaogang; Cai, Manyuan; Chen, Long; Qiu, Zhiwen; Liu, Zhenghong

    2017-07-01

    A flexible composite paper of multi-walled carbon nanotube (MWCNT) and cellulose fiber (CF) were fabricated by traditional paper-making method. Then, the MWCNT/CF papers were carbonized at high temperature in vacuum to remove organic component. The carbonized MWCNT/CF (MWCNT/CCF) papers are consisted of MWCNT and carbon fiber. The papers were characterized by scanning electron microscope (SEM), X-ray diffraction (XRD), and four-point probe resistance meter. The electrochemical performances of the supercapacitors were tested by cyclic voltammetry and galvanostatic charge/discharge >with 1 moL/L LiPF6 as electrolyte. The MWCNT/CCF electrode yielded a specific capacitance of 156F/g at a current density of 50 mA/g by galvanostatic charge/discharge measurement, which is 1.29 times higher than MWCNT/CF electrode of 68F/g. The MWCNT/CCF electrodes also displayed an excellent specific capacitance retention of 84% after 2000 continuous charge/discharge cycles at a current density of 400 mA/g. The increase of specific capacitance can be attributed to enhanced electrical conductivity of MWCNT/CCF papers and improved contact interface between electrolyte and electrodes.

  13. Extraction of network topology from multi-electrode recordings: Is there a small-world effect?

    Directory of Open Access Journals (Sweden)

    Felipe eGerhard

    2011-02-01

    Full Text Available The simultaneous recording of the activity of many neurons poses challenges for multivariate data analysis. Here, we propose a general scheme of reconstruction of the functional network from spike train recordings. Effective, causal interactions are estimated by fitting Generalized Linear Models (GLMs on the neural responses, incorporating effects of the neurons' self-history, of input from other neurons in the recorded network and of modulation by an external stimulus. The coupling terms arising from synaptic input can be transformed by thresholding into a binary connectivity matrix which is directed. Each link between two neurons represents a causal influence from one neuron to the other, given the observation of all other neurons from the population. The resulting graph is analyzed with respect to small-world and scale-free properties using quantitative measures for directed networks. Such graph-theoretic analyses have been performed on many complex dynamic networks, including the connectivity structure between different brain areas. Only few studies have attempted to look at the structure of cortical neural networks on the level of individual neurons. Here, using multi-electrode recordings from the visual system of the awake monkey, we find that cortical networks lack scale-free behavior, but show a small, but significant small-world structure. Assuming a simple distance-dependent probabilistic wiring between neurons, we find that this connectivity structure can account for all of the networks' observed small-world-ness. Moreover, for multi-electrode recordings the sampling of neurons is not uniform across the population. We show that the small-world-ness obtained by such a localized sub-sampling overestimates the strength of the true small-world-structure of the network. This bias is likely to be present in all previous experiments based on multi-electrode recordings.

  14. Complications and Short-Term Explantation Rate Following Artificial Urinary Sphincter Implantation: Results from a Large Middle European Multi-Institutional Case Series.

    Science.gov (United States)

    Kretschmer, Alexander; Hüsch, Tanja; Thomsen, Frauke; Kronlachner, Dominik; Obaje, Alice; Anding, Ralf; Pottek, Tobias; Rose, Achim; Olianas, Roberto; Friedl, Alexander; Hübner, Wilhelm; Homberg, Roland; Pfitzenmaier, Jesco; Grein, Ulrich; Queissert, Fabian; Naumann, Carsten Maik; Schweiger, Josef; Wotzka, Carola; Nyarangi-Dix, Joanne N; Hofmann, Torben; Seiler, Roland; Haferkamp, Axel; Bauer, Ricarda M

    2016-01-01

    Background/Aims/Objectives: To analyze perioperative complication and short-term explantation rates after perineal or penoscrotal single-cuff and double-cuff artificial urinary sphincter (AUS) implantation in a large middle European multi-institutional patient cohort. 467 male patients with stress urinary incontinence underwent implantation of a perineal single-cuff (n = 152), penoscrotal single-cuff (n = 99), or perineal double-cuff (n = 216) AUS between 2010 and 2012. Postoperative complications and 6-month explantation rates were assessed. For statistical analysis, Fisher's exact test and Kruskal-Wallis rank sum test, and a multiple logistic regression model were used (p AUS, penoscrotal single-cuff implantation led to significantly increased short-term explantation rates (8.6% (perineal) vs. 19.2% (penoscrotal), p = 0.019). The postoperative infection rate was significantly higher after double-cuff compared to single-cuff implantation (6.0% (single-cuff) vs. 13.9% (double-cuff), p = 0.019). The short-term explantation rate after primary double-cuff placement was 6.5% (p = 0.543 vs. perineal single-cuff). In multivariate analysis, the penoscrotal approach (p = 0.004), intraoperative complications (p = 0.005), postoperative bleeding (p = 0.011), and perioperative infection (p < 0.001) were independent risk factors for short-term explantation. Providing data from a large contemporary multi-institutional patient cohort from high-volume and low-volume institutions, our results reflect the current standard of care in middle Europe. We indicate that the penoscrotal approach is an independent risk factor for increased short-term explantation rates. © 2016 S. Karger AG, Basel.

  15. Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

    Directory of Open Access Journals (Sweden)

    Paolo Consigliere

    2017-01-01

    Full Text Available Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patches has gained popularity in recent years with the aim of reducing failure.The aim of this study was to investigate the outcome of rotator cuff repairs augmented with denatured extracellular matrix in a series of patients who underwent arthroscopic rotator cuff repair for large to massive tears.Methods: Ten consecutive patients, undergoing arthroscopic rotator cuff repair with extracellular matrix augment for large and massive tears, were prospectively enrolled into this single surgeon study. All repairs were performed arthroscopically with a double row technique augmented with extracellular matrix. Oxford Shoulder Score, Constant Score and pain visual analogue scale (VAS were used to monitor the shoulder function and outcome pre-operatively and at three, six and 12-month follow-up. Minimum follow up was tree months. Mean follow up was 7 months.Results: Mean Constant score improved from 53 (SD=4 pre-operatively to 75 (SD=11 at final follow up. Mean Oxford score also increased from 30 (SD=8 pre-operatively to 47 (SD=10 at the final follow up. The visual analogue scale (VAS improved from seven out of 10 (SD=2 preoperatively to 0.6 (SD=0.8 at final follow up. Additionally, there was significant improvement at three months mark in Constant score. Conclusion: Arthroscopic repair and augmentation of large and massive rotator cuff tears with extracellular matrix patch has good early outcome.

  16. The Societal and Economic Value of Rotator Cuff Repair

    Science.gov (United States)

    Mather, Richard C.; Koenig, Lane; Acevedo, Daniel; Dall, Timothy M.; Gallo, Paul; Romeo, Anthony; Tongue, John; Williams, Gerald

    2013-01-01

    Background: Although rotator cuff disease is a common musculoskeletal problem in the United States, the impact of this condition on earnings, missed workdays, and disability payments is largely unknown. This study examines the value of surgical treatment for full-thickness rotator cuff tears from a societal perspective. Methods: A Markov decision model was constructed to estimate lifetime direct and indirect costs associated with surgical and continued nonoperative treatment for symptomatic full-thickness rotator cuff tears. All patients were assumed to have been unresponsive to one six-week trial of nonoperative treatment prior to entering the model. Model assumptions were obtained from the literature and data analysis. We obtained estimates of indirect costs using national survey data and patient-reported outcomes. Four indirect costs were modeled: probability of employment, household income, missed workdays, and disability payments. Direct cost estimates were based on average Medicare reimbursements with adjustments to an all-payer population. Effectiveness was expressed in quality-adjusted life years (QALYs). Results: The age-weighted mean total societal savings from rotator cuff repair compared with nonoperative treatment was $13,771 over a patient’s lifetime. Savings ranged from $77,662 for patients who are thirty to thirty-nine years old to a net cost to society of $11,997 for those who are seventy to seventy-nine years old. In addition, surgical treatment results in an average improvement of 0.62 QALY. Societal savings were highly sensitive to age, with savings being positive at the age of sixty-one years and younger. The estimated lifetime societal savings of the approximately 250,000 rotator cuff repairs performed in the U.S. each year was $3.44 billion. Conclusions: Rotator cuff repair for full-thickness tears produces net societal cost savings for patients under the age of sixty-one years and greater QALYs for all patients. Rotator cuff repair is cost

  17. A magnetically levitated electrode ionization chamber of the noncontact measurement type

    International Nuclear Information System (INIS)

    Kawaguchi, Toshiro; Yoshimura, Atsushi

    2002-01-01

    A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the γ-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ionization current when accumulated for 1 h is about 1.3x10 -17 A

  18. A magnetically levitated electrode ionization chamber of the noncontact measurement type

    CERN Document Server

    Kawaguchi, T

    2002-01-01

    A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the gamma-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ionization current when accumulated for 1 h is a...

  19. Hypertrophic changes of the teres minor muscle in rotator cuff tears: quantitative evaluation by magnetic resonance imaging.

    Science.gov (United States)

    Kikukawa, Kenshi; Ide, Junji; Kikuchi, Ken; Morita, Makoto; Mizuta, Hiroshi; Ogata, Hiroomi

    2014-12-01

    Few reports have assessed the teres minor (TM) muscle in rotator cuff tears. This study aimed to quantitatively analyze the morphologic changes of the TM muscle in patients with or without rotator cuff tears by magnetic resonance imaging (MRI). This retrospective study consisted of 279 subjects classified on the basis of interpretations of conventional MRI observations into 6 groups: no cuff tear; partial-thickness supraspinatus (SSP) tear; full-thickness SSP tear; SSP and subscapularis tears; SSP and infraspinatus (ISP) tears; and SSP, ISP, and subscapularis tears. With use of ImageJ software (National Institutes of Health, Bethesda, MD, USA) for oblique sagittal MRI, we measured the areas of ISP, TM, and anatomic external rotation (ISP + TM) muscles on the most lateral side in which the scapular spine was in contact with the scapular body. The occupational ratios of the TM muscle area to the anatomic external rotation muscle area were calculated. Ratios above the maximum of the 95% confidence intervals of the occupational ratio in the no-tear group were defined as hypertrophy of the TM muscle. Occupational ratios of the TM muscle in the no-tear group followed a normal distribution, and ratios >0.288 were defined as hypertrophic. Hypertrophic changes of the TM muscle were confirmed in rotator cuff tears involving the ISP tendon. A negative correlation was found between the occupational ratios of TM and ISP (P muscle appeared hypertrophic in rotator cuff tears involving the ISP, and the progression of ISP muscle atrophy seemed to induce the development of this compensatory hypertrophy. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Progression from calcifying tendinitis to rotator cuff tear

    Energy Technology Data Exchange (ETDEWEB)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke [Department of Orthopaedic Surgery, Medical Center of Kurume University, 155-1 Kokubu-machi, Kurume City, Fukuoka 839-0862 (Japan)

    2003-02-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  1. Progression from calcifying tendinitis to rotator cuff tear

    International Nuclear Information System (INIS)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke

    2003-01-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  2. Safety and efficacy of a multi-electrode renal sympathetic denervation system in resistant hypertension: the EnligHTN I trial.

    Science.gov (United States)

    Worthley, Stephen G; Tsioufis, Costas P; Worthley, Matthew I; Sinhal, Ajay; Chew, Derek P; Meredith, Ian T; Malaiapan, Yuvi; Papademetriou, Vasilios

    2013-07-01

    Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the EnligHTN(™) multi-electrode system. We conducted the first-in-human, prospective, multi-centre, non-randomized study in 46 patients (67% male, mean age 60 years, and mean baseline office blood pressure 176/96 mmHg) with drug-resistant hypertension. The primary efficacy objective was change in office blood pressure from baseline to 6 months. Safety measures included all adverse events with a focus on the renal artery and other vascular complications and changes in renal function. Renal artery denervation, using the EnligHTN system significantly reduced the office blood pressure from baseline to 1, 3, and 6 months by -28/10, -27/10 and -26/10 mmHg, respectively (P renal artery injury or other serious vascular complications occurred. Small, non-clinically relevant, changes in average estimated glomerular filtration rate were reported from baseline (87 ± 19 mL/min/1.73 m2) to 6 months post-procedure (82 ± 20 mL/min/1.73 m2). Renal sympathetic denervation, using the EnligHTN multi-electrode catheter results in a rapid and significant office blood pressure reduction that was sustained through 6 months. The EnligHTN system delivers a promising therapy for the treatment of drug-resistant hypertension.

  3. Current Enhancement with Contact-Area-Limited Doping for Bottom-Gate, Bottom-Contact Organic Thin-Film Transistors

    Science.gov (United States)

    Noda, Kei; Wakatsuki, Yusuke; Yamagishi, Yuji; Wada, Yasuo; Toyabe, Toru; Matsushige, Kazumi

    2013-02-01

    The current enhancement mechanism in contact-area-limited doping for bottom-gate, bottom-contact (BGBC) p-channel organic thin-film transistors (OTFTs) was investigated both by simulation and experiment. Simulation results suggest that carrier shortage and large potential drop occur in the source-electrode/channel interface region in a conventional BGBC OTFT during operation, which results in a decrease in the effective field-effect mobility. These phenomena are attributed to the low carrier concentration of active semiconductor layers in OTFTs and can be alleviated by contact-area-limited doping, where highly doped layers are prepared over source-drain electrodes. According to two-dimensional current distribution obtained from the device simulation, a current flow from the source electrode to the channel region via highly doped layers is generated in addition to the direct carrier injection from the source electrode to the channel, leading to the enhancement of the drain current and effective field-effect mobility. The expected current enhancement mechanism in contact-area-limited doping was experimentally confirmed in typical α-sexithiophene (α-6T) BGBC thin-film transistors.

  4. Transtendon rotator-cuff repair of partial-thickness articular surface tears can lead to medial rotator-cuff failure

    Directory of Open Access Journals (Sweden)

    Woods TC

    2014-06-01

    Full Text Available Tom C Woods,4 Michael J Carroll,1 Atiba A Nelson,2 Kristie D More,2 Randa Berdusco,1 Stephen Sohmer,3 Richard S Boorman,1,2 Ian KY Lo1,21Department of Surgery, 2Sport Medicine Centre, University of Calgary, Calgary, AB, Canada; 3Department of Orthopaedics, University of British Columbia, Vancouver, 4St Joseph's Hospital, Comox, BC, CanadaPurpose: The purpose of this study was to evaluate clinical and anatomic outcomes of patients following transtendon rotator-cuff repair of partial articular supraspinatus tendon avulsion (PASTA lesions.Patients and methods: Patients in the senior author's practice who had isolated PASTA lesions treated by transtendon rotator-cuff repair were included (n=8 and retrospectively reviewed. All patients were evaluated preoperatively and at a mean of 21.2 months (±9.7 months postoperatively using standardized clinical evaluation (physical exam, American Shoulder and Elbow Surgeons, and Simple Shoulder Test. All patients underwent postoperative imaging with a magnetic resonance imaging arthrogram.Results: There was a significant improvement in American Shoulder and Elbow Surgeons (42.7±17.5 to 86.9±25.2 and Simple Shoulder Test (4.6±3.2 to 10.1±3.8 scores from pre- to postoperative, respectively. Postoperative imaging demonstrated full-thickness medial cuff tearing in seven patients, and one patient with a persistent partial articular surface defect.Conclusion: Transtendon repair of PASTA lesions may lead to improvements in clinical outcome. However, postoperative imaging demonstrated a high incidence of full-thickness rotator-cuff defects following repair.Keywords: rotator cuff, PASTA lesion, transtendon repair

  5. Release of obstructing rectal cuff following transanal endorectal ...

    African Journals Online (AJOL)

    symptoms after transanal endorectal pullthrough for ... In both patients, the obstructing symptoms were because of a rectal cuff ... widely adopted for the treatment of Hirschsprung's disease ... The cuff was identified and cut strictly in the midline.

  6. Cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode as electrochemical sensor on microfluidic chip

    International Nuclear Information System (INIS)

    Li Xinchun; Chen Zuanguang; Zhong Yuwen; Yang Fan; Pan Jianbin; Liang Yajing

    2012-01-01

    Highlights: ► CoHCF nanoparticles modified MWCNTs/graphite electrode use for electrochemistry on electrophoresis microchip for the first time. ► Simultaneous, rapid, and sensitive electrochemical detection of hydrazine and isoniazid in real samples. ► An exemplary work of CME sensor assembly onto microchip for determination of analytes with environmental significance. ► Manifestation of the applicability and flexibility of CME sensor for electroanalysis on microfluidic chip. - Abstract: Nanomaterial-based electrochemical sensor has received significant interest. In this work, cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode was electrochemically prepared and exploited as an amperometric detector for microchip electrophoresis. The prepared sensor displayed rapid and sensitive response towards hydrazine and isoniazid oxidation, which was attributed to synergetic electrocatalytic effect of cobalt hexacyanoferrate and multi-walled carbon nanotubes. The sensitivity enhancement with nearly two orders of magnitude was gained, compared with the bare carbon paste electrode, with the detection limit of 0.91 μM (S/N = 3) for hydrazine. Acceptable repeatability of the microanalysis system was verified by consecutive eleven injections of hydrazine without chip and electrode treatments, the RSDs for peak current and migration time were 3.4% and 2.1%, respectively. Meanwhile, well-shaped electrophoretic peaks were observed, mainly due to fast electron transfer of electroactive species on the modified electrode. The developed microchip-electrochemistry setup was successfully applied to the determination of hydrazine and isoniazid in river water and pharmaceutical preparation, respectively. Several merits of the novel electrochemical sensor coupled with microfluidic platform, such as comparative stability, easy fabrication and high sensitivity, hold great potential for hydrazine compounds assay in the lab-on-a-chip system.

  7. The “Parachute” Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint

    OpenAIRE

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-01-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by ...

  8. Conductive Hydrogel Electrodes for Delivery of Long-Term High Frequency Pulses

    Directory of Open Access Journals (Sweden)

    Naomi A. Staples

    2018-01-01

    Full Text Available Nerve block waveforms require the passage of large amounts of electrical energy at the neural interface for extended periods of time. It is desirable that such waveforms be applied chronically, consistent with the treatment of protracted immune conditions, however current metal electrode technologies are limited in their capacity to safely deliver ongoing stable blocking waveforms. Conductive hydrogel (CH electrode coatings have been shown to improve the performance of conventional bionic devices, which use considerably lower amounts of energy than conventional metal electrodes to replace or augment sensory neuron function. In this study the application of CH materials was explored, using both a commercially available platinum iridium (PtIr cuff electrode array and a novel low-cost stainless steel (SS electrode array. The CH was able to significantly increase the electrochemical performance of both array types. The SS electrode coated with the CH was shown to be stable under continuous delivery of 2 mA square pulse waveforms at 40,000 Hz for 42 days. CH coatings have been shown as a beneficial electrode material compatible with long-term delivery of high current, high energy waveforms.

  9. Use of cuff tear arthroplasty head prosthesis for rotator cuff arthropathy treatment in elderly patients with comorbidities.

    Science.gov (United States)

    Carvalho, Cassiano Diniz; Andreoli, Carlos Vicente; Pochini, Alberto de Castro; Ejnisman, Benno

    2016-01-01

    To evaluate the clinical and functional behavior of patients undergoing cuff tear arthroplasty at different stages of the disease. Cuff tear arthroplasty hemiarthroplasties were performed in 34 patients with rotator cuff arthropathy and associated comorbidities, classified according to Seebauer. The mean age was 76.3 years, and the sample comprised 23 females (67.6%) and 11 males (32.4%). The mean follow-up period was 21.7 months, and evaluations were performed using the Visual Analog Scale for pain and the Constant scale. There were no statistically significant differences in the mean reduction in the Visual Analog Scale or in the Constant scale increase between the female and male groups. The variation between the pre- and postoperative Visual Analog Scale and Constant scale evaluations was significant. There was also no statistically significant difference between the Seebauer classification groups regarding the mean Visual Analog Scale reduction, or the mean Constant scale increase. Cuff tear arthroplasty shoulder hemiarthroplasty is a good option for rotator cuff arthropathy in patients with comorbidities. Avaliar o comportamento clínico e funcional dos pacientes submetidos à artroplastia do tipo cuff tear arthroplasty para o tratamento da artropatia do manguito rotador em diferentes estágios da afecção. Foram realizadas 34 hemiartroplastias do tipo cuff tear arthroplasty em 34 pacientes com artropatia do manguito rotador e comorbidades associadas, classificadas de acordo com Seebauer. A média de idade foi de 76,3 anos, sendo 23 pacientes do sexo feminino (67,6%) e 11 do sexo masculino (32,4%). O seguimento médio foi de 21,7 meses e a avaliação foi realizada por meio da Escala Visual Analógica da dor e pela escala de Constant. Não houve diferença estatisticamente significante entre os grupos feminino e masculino, tanto nas médias de redução na Escala Visual Analógica quanto nas de aumento na escala de Constant. A variação entre as avalia

  10. Automatic monitoring of radial injection tracer tests using a novel multi-electrode resistivity system

    International Nuclear Information System (INIS)

    Ward, R.S.; Sen, M.A.; Williams, G.M.; Jackson, P.D.

    1990-01-01

    A radial injection tracer test has been carried out in an unconfined fluvial sand and gravel aquifer underlain by low permeability clay. Sodium chloride has been used as an electrolyte tracer and breakthrough has been monitored using a newly developed automatic resistivity system (RESCAN) incorporating six fully penetrating resistivity probes each having 80 electrodes spaced at 5 cm intervals along their length. Each electrode is individually addressable under computer control to either carry current or measure potential. Any four electrodes can be selected in the traditional Wenner configuration to measure formation resistivity. Rapid measurement of changes in resistivity allows a very detailed picture of tracer migration to be obtained. The resistivity probes were placed at 1 and 2 m radii from the central fully-screened tracer injection well along three limbs at 120 degrees. Resistivity measurements were compared with adjacent multi-level samplers. An 8 x 8 m grid of 140 surface electrodes centred on the central well was also installed. The resistivity profiles measured prior to tracer injection were used to infer lithology, particularly layering. Detailed breakthrough curves were obtained at 77 positions along each of the six probes and compared with adjacent multi-level sampler breakthrough curves. The results showed that the aquifer was extremely heterogeneous even on this small scale. Because the system operates automatically without the need to extract and analyse large numbers of water samples, it opens up the possibility of carrying out lots of small scale injection tests within a larger domain likely to be invaded by a tracer or pollution plume. Such detailed information for determining aquifer properties can provide the data set necessary for characterisation of the aquifer to predict dispersion parameters appropriate to the large scale. (Author) (6 refs., 9 figs., 2 tabs.)

  11. Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    Science.gov (United States)

    Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.

    2015-01-01

    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095

  12. A split microdrive for simultaneous multi-electrode recordings from two brain areas in awake small animals.

    NARCIS (Netherlands)

    Lansink, C.S.; Bakker, M.; Buster, W.; Lankelma, J.; van der Blom, R.; Westdorp, R.; Joosten, R.N.J.M.A.; Mc.Naughton, B.L.; Pennartz, C.M.A.

    2007-01-01

    Complex cognitive operations such as memory formation and decision-making are thought to be mediated not by single, isolated brain structures but by multiple, connected brain areas. To facilitate studies on the neural communication between connected brain structures, we developed a multi-electrode

  13. Methods for Specific Electrode Resistance Measurement during Transcranial Direct Current Stimulation

    Science.gov (United States)

    Khadka, Niranjan; Rahman, Asif; Sarantos, Chris; Truong, Dennis Q.; Bikson, Marom

    2014-01-01

    Background Transcranial Direct Current Stimulation (tDCS) is investigated to treat a wide range of neuropsychiatric disorders, for rehabilitation, and for enhancing cognitive performance. The monitoring of electrode resistance before and during tDCS is considered important for tolerability and safety, where an unusually high resistance is indicative of undesired electrode or poor skin contact conditions. Conventional resistance measurement methods do not isolate individual electrode resistance but rather measures overall voltage. Moreover, for HD-tDCS devices, cross talk across electrodes makes concurrent resistance monitoring unreliable. Objective We propose a novel method for monitoring of the individual electrode resistance during tDCS, using a super-position of direct current with a test-signal (low-intensity and low-frequency sinusoids with electrode– specific frequencies) and a single sentinel electrode (not used for DC). Methods To validate this methodology, we developed lumped-parameter models of two and multi-electrode tDCS. Approaches with and without a sentinel electrode were solved and underlying assumptions identified. Assumptions were tested and parameterized in healthy participants using forearm stimulation combining tDCS (2 mA) and sinusoidal test-signals (38 μA and 76 μA peak to peak at 1 Hz, 10 Hz, and 100 Hz) and an in vitro test (where varied electrode failure modes were created). DC and AC component voltages across the electrodes were compared and participants were asked to rate subjective pain. Results A sentinel electrode is required to isolate electrode resistance in a two-electrode tDCS system. For multi-electrode resistance tracking, cross talk was aggravated with electrode proximity and current/resistance mismatches, but could be corrected using proposed approaches. Average voltage and average pain scores were not significantly different across test current intensities and frequencies (two-way repeated measures ANOVA) indicating the

  14. Standard sonography and arthrosonography in the study of rotator cuff tears

    International Nuclear Information System (INIS)

    El-Dalati, Ghassan; Martone, Enrico; Caffarri, Sabrina; Fusaro, Michele; Pozzi Mucelli, Roberto; Castellarin, Gianluca; Ricci, Matteo; Vecchini, Eugenio

    2005-01-01

    Purpose. The aim of this study was to evaluate the sensitivity of ultrasonography, integrating standard ultrasound and arthrosonography after injecting a saline solution into the glenohumeral cavity in cases of suspected rotator cuff tears. Materials and methods. We respectively examinated 40 patients awaiting shoulder arthroscopy for suspected or diagnosed tears of the rotator cuff. A radiologist, unaware of the pre-operative diagnosis, performed an ultrasound scan on all the patients before and after the injection of saline solution into the glenohumeral cavity. The parameters considered were presence or absence of a rotator cuff injury; type of injury according to Snyder and its extent along the longitudinal and transverse planes; presence or absence of effusion into the articular cavity; subacromial/subdeltoid bursal distension. All the patients underwent arthroscopy either the same day of the day after the ultrasound examination. Results. Standard sonography showed 26 complete rotator cuff tears (type C according to Snyder), 2 partial tears (type B according to Snyder) and 12 intact rotator cuffs. Arthrosonography detected 31 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Arthroscopy identified 32 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Analysis of the results shows that, taking arthroscopy as the gold standard, the sensitivity of normal sonography is 81.2%, whereas that of arthosonography is 96.8% (p [it

  15. Glassy carbon electrode modified with multi-walled carbon nanotubes sensor for the quantification of antihistamine drug pheniramine in solubilized systems

    Directory of Open Access Journals (Sweden)

    Rajeev Jain

    2012-02-01

    Full Text Available A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with multi-walled carbon nanotubes in the presence of sodium lauryl sulfate. The experimental results suggest that the pheniramine in anionic surfactant solution exhibits electrocatalytic effect resulting in a marked enhancement of the peak current response. Peak current response is linearly dependent on the concentration of pheniramine in the range 200–1500 μg/mL with correlation coefficient 0.9987. The limit of detection is 58.31 μg/mL. The modified electrode shows good sensitivity and repeatability. Keywords: Pheniramine, Sodium lauryl sulfate (SLS, Glassy carbon electrode modified with multi-walled carbon nanotubes (GCE-MWCNTs, Solubilized systems, Voltammetric quantification

  16. Diffusion-controlled oxygen reduction on multi-copper oxidase-adsorbed carbon aerogel electrodes without mediator

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, S.; Kamitaka, Y.; Kano, K. [Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto (Japan)

    2007-12-15

    Bioelectrocatalytic reduction of O{sub 2} into water was archived at diffusion-controlled rate by using enzymes (laccase from Trametes sp. and bilirubin oxidase from Myrothecium verrucaria, which belong to the family of multi-copper oxidase) adsorbed on mesoporous carbon aerogel particle without a mediator. The current density was predominantly controlled by the diffusion of dissolved O{sub 2} in rotating-disk electrode experiments, and reached a value as large as 10 mA cm{sup -2} at 1 atm O{sub 2}, 25 C, and 8,000 rpm on the laccase-adsorbed electrode. The overpotential of the bioelectrocatalytic reduction of O{sub 2} was 0.4-0.55 V smaller than that observed on a Pt disk electrode. Without any optimization, the laccase-adsorbed biocathode showed stable current intensity of the O{sub 2} reduction in an air-saturated buffer at least for 10 days under continuous flow system. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  17. Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation

    International Nuclear Information System (INIS)

    Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty; Grigsby, Perry W.

    2012-01-01

    Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of the fiducial markers on the simulation CT. Composite dose–volume histograms were also created by summing daily target positions. Results: The average (± standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 ± 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 ± 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 ± 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.

  18. Regenerative Medicine in Rotator Cuff Injuries

    Science.gov (United States)

    Randelli, Pietro; Ragone, Vincenza; Menon, Alessandra; Cabitza, Paolo; Banfi, Giuseppe

    2014-01-01

    Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP) is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs). Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research. PMID:25184132

  19. Regenerative Medicine in Rotator Cuff Injuries

    Directory of Open Access Journals (Sweden)

    Pietro Randelli

    2014-01-01

    Full Text Available Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs. Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research.

  20. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...

  1. High performance cermet electrodes

    Science.gov (United States)

    Isenberg, Arnold O.; Zymboly, Gregory E.

    1986-01-01

    Disclosed is a method of increasing the operating cell voltage of a solid oxide electrochemical cell having metal electrode particles in contact with an oxygen-transporting ceramic electrolyte. The metal electrode is heated with the cell, and oxygen is passed through the oxygen-transporting ceramic electrolyte to the surface of the metal electrode particles so that the metal electrode particles are oxidized to form a metal oxide layer between the metal electrode particles and the electrolyte. The metal oxide layer is then reduced to form porous metal between the metal electrode particles and the ceramic electrolyte.

  2. Built-in test of electrode degradation of multi-electrode array biosensors

    NARCIS (Netherlands)

    Liu, H.Y.; Dumas, N.; Richardson, A.; Heal, R.; Kerkhoff, Hans G.

    2006-01-01

    Micro-electrode array (MEA) is a widely used platform in biosensor systems, which provide a technology in communicating with micro chemical and biological world. This paper addresses hte topic of testing micro electrode degradation for MEAs, which is a common encountered damage during its

  3. Non-contact radio frequency shielding and wave guiding by multi-folded transformation optics method.

    Science.gov (United States)

    Madni, Hamza Ahmad; Zheng, Bin; Yang, Yihao; Wang, Huaping; Zhang, Xianmin; Yin, Wenyan; Li, Erping; Chen, Hongsheng

    2016-11-14

    Compared with conventional radio frequency (RF) shielding methods in which the conductive coating material encloses the circuits design and the leakage problem occurs due to the gap in such conductive material, non-contact RF shielding at a distance is very promising but still impossible to achieve so far. In this paper, a multi-folded transformation optics method is proposed to design a non-contact device for RF shielding. This "open-shielded" device can shield any object at a distance from the electromagnetic waves at the operating frequency, while the object is still physically open to the outer space. Based on this, an open-carpet cloak is proposed and the functionality of the open-carpet cloak is demonstrated. Furthermore, we investigate a scheme of non-contact wave guiding to remotely control the propagation of surface waves over any obstacles. The flexibilities of such multi-folded transformation optics method demonstrate the powerfulness of the method in the design of novel remote devices with impressive new functionalities.

  4. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  5. Epidemiology, natural history, and indications for treatment of rotator cuff tears.

    Science.gov (United States)

    Tashjian, Robert Z

    2012-10-01

    The etiology of rotator cuff disease is likely multifactorial, including age-related degeneration and microtrauma and macrotrauma. The incidence of rotator cuff tears increases with aging with more than half of individuals in their 80s having a rotator cuff tear. Smoking, hypercholesterolemia, and genetics have all been shown to influence the development of rotator cuff tearing. Substantial full-thickness rotator cuff tears, in general, progress and enlarge with time. Pain, or worsening pain, usually signals tear progression in both asymptomatic and symptomatic tears and should warrant further investigation if the tear is treated conservatively. Larger (>1-1.5 cm) symptomatic full-thickness cuff tears have a high rate of tear progression and, therefore, should be considered for earlier surgical repair in younger patients if the tear is reparable and there is limited muscle degeneration to avoid irreversible changes to the cuff, including tear enlargement and degenerative muscle changes. Smaller symptomatic full-thickness tears have been shown to have a slower rate of progression, similar to partial-thickness tears, and can be considered for initial nonoperative treatment due to the limited risk for rapid tear progression. In both small full-thickness tears and partial-thickness tears, increasing pain should alert physicians to obtain further imaging as it can signal tear progression. Natural history data, along with information on factors affecting healing after rotator cuff repair, can help guide surgeons in making appropriate decisions regarding the treatment of rotator cuff tears. The management of rotator cuff tears should be considered in the context of the risks and benefits of operative versus nonoperative treatment. Tear size and acuity, the presence of irreparable changes to the rotator cuff or glenohumeral joint, and patient age should all be considered in making this decision. Initial nonoperative care can be safely undertaken in older patients (>70

  6. Improper tube fixation causing a leaky cuff

    Directory of Open Access Journals (Sweden)

    Gupta Babita

    2010-01-01

    Full Text Available Leaking endotracheal tube cuffs are common problems in intensive care units. We report a case wherein the inflation tube was damaged by the adhesive plaster used for tube fixation and resulted in leaking endotracheal tube cuff. We also give some suggestions regarding the tube fixation and some remedial measures for damaged inflation system.

  7. Insulating electrodes: a review on biopotential front ends for dielectric skin–electrode interfaces

    International Nuclear Information System (INIS)

    Spinelli, Enrique; Haberman, Marcelo

    2010-01-01

    Insulating electrodes, also known as capacitive electrodes, allow acquiring biopotentials without galvanic contact with the body. They operate with displacement currents instead of real charge currents, and the electrolytic electrode–skin interface is replaced by a dielectric film. The use of insulating electrodes is not the end of electrode interface problems but the beginning of new ones: coupling capacitances are of the order of pF calling for ultra-high input impedance amplifiers and careful biasing, guarding and shielding techniques. In this work, the general requirements of front ends for capacitive electrodes are presented and the different contributions to the overall noise are discussed and estimated. This analysis yields that noise bounds depend on features of the available devices as current and voltage noise, but the final noise level also depends on parasitic capacitances, requiring a careful shield and printed circuit design. When the dielectric layer is placed on the skin, the present-day amplifiers allow achieving noise levels similar to those provided by wet electrodes. Furthermore, capacitive electrode technology allows acquiring high quality ECG signals through thin clothes. A prototype front end for capacitive electrodes was built and tested. ECG signals were acquired with these electrodes in direct contact with the skin and also through cotton clothes 350 µm thick. They were compared with simultaneously acquired signals by means of wet electrodes and no significant differences were observed between both output signals

  8. Top-Contact Pentacene-Based Organic Thin Film Transistor (OTFT) with N, N'-Bis(3-Methyl Phenyl)- N, N'-Diphenyl Benzidine (TPD)/Au Bilayer Source-Drain Electrode

    Science.gov (United States)

    Borthakur, Tribeni; Sarma, Ranjit

    2018-01-01

    A top-contact Pentacene-based organic thin film transistor (OTFT) with N, N'-Bis (3-methyl phenyl)- N, N'-diphenyl benzidine (TPD)/Au bilayer source-drain electrode is reported. The devices with TPD/Au bilayer source-drain (S-D) electrodes show better performance than the single layer S-D electrode OTFT devices. The field-effect mobility of 4.13 cm2 v-1 s-1, the on-off ratio of 1.86 × 107, the threshold voltage of -4 v and the subthreshold slope of .27 v/decade, respectively, are obtained from the device with a TPD/Au bilayer source-drain electrode.

  9. In Vivo Measurement of Glenohumeral Joint Contact Patterns

    Directory of Open Access Journals (Sweden)

    Bey MichaelJ

    2010-01-01

    Full Text Available The objectives of this study were to describe a technique for measuring in-vivo glenohumeral joint contact patterns during dynamic activities and to demonstrate application of this technique. The experimental technique calculated joint contact patterns by combining CT-based 3D bone models with joint motion data that were accurately measured from biplane x-ray images. Joint contact patterns were calculated for the repaired and contralateral shoulders of 20 patients who had undergone rotator cuff repair. Significant differences in joint contact patterns were detected due to abduction angle and shoulder condition (i.e., repaired versus contralateral. Abduction angle had a significant effect on the superior/inferior contact center position, with the average joint contact center of the repaired shoulder 12.1% higher on the glenoid than the contralateral shoulder. This technique provides clinically relevant information by calculating in-vivo joint contact patterns during dynamic conditions and overcomes many limitations associated with conventional techniques for quantifying joint mechanics.

  10. Evolution of surface motor activation zones in hemiplegic patients during 20 sessions of FES therapy with multi-pad electrodes

    Directory of Open Access Journals (Sweden)

    Jovana Malešević

    2016-06-01

    Full Text Available The purpose of this study was to examine surface motor activation zones for wrist, fingers and thumb extension movements and their temporal change during 20 therapy sessions using advanced multi-pad functional electrical stimulation system. Results from four hemiplegic patients indicate that certain zones have higher probability of eliciting each of the target movements. However, mutual overlap and variations of the zones are present not just between the subjects, but also on the intrasubject level, reflected through these session to session transformations of the selected virtual electrodes. The obtained results could be used as a priori knowledge for semi-automated optimization algorithm and could shorten the time required for calibration of the multi-pad electrode.

  11. Antimicrobial efficacy assessment of multi-use solution to disinfect hydrophilic contact lens, in vitro

    OpenAIRE

    Lui,Aline Cristina Fioravanti; Netto,Adamo Lui; Silva,Cely Barreto da; Hida,Richard; Mendes,Thais Sousa; Lui,Giovana Arlene Fioravanti; Gemperli,Daniela Barbosa; Vital,Enderson Dantas

    2009-01-01

    PURPOSE: To evaluate the efficacy of disinfecting solutions in hydrophilic contact lenses (CL). METHODS: Two multi-use solutions denominated solution A (0.001% polyquaternium-1 and 0.0005% myristamidopropyl dimethylamine) and solution B (0.0001% polyaminopropyl biguanide) were used. The solutions were tested in hydrophilic contact lenses infected with Pseudomonas aeruginosa (ATCC27583), Staphylococcus epidermidis (ATCC1226), Klebsiella pneumoniae (ATCC13883), Staphylococcus aureus (ATCC25923)...

  12. Cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode as electrochemical sensor on microfluidic chip

    Energy Technology Data Exchange (ETDEWEB)

    Li Xinchun [School of Pharmaceutical Sciences, Sun Yat-sen University, 132 Waihuan East Road of Higher Education Mega Centre, Guangzhou 510006 (China); Chen Zuanguang, E-mail: chenzg@mail.sysu.edu.cn [School of Pharmaceutical Sciences, Sun Yat-sen University, 132 Waihuan East Road of Higher Education Mega Centre, Guangzhou 510006 (China); Zhong Yuwen, E-mail: yu0106@163.com [Center for Disease Control and Prevention of Guangdong Province, 176 Xingangxi, Guangzhou 510300 (China); Yang Fan; Pan Jianbin; Liang Yajing [School of Pharmaceutical Sciences, Sun Yat-sen University, 132 Waihuan East Road of Higher Education Mega Centre, Guangzhou 510006 (China)

    2012-01-13

    Highlights: Black-Right-Pointing-Pointer CoHCF nanoparticles modified MWCNTs/graphite electrode use for electrochemistry on electrophoresis microchip for the first time. Black-Right-Pointing-Pointer Simultaneous, rapid, and sensitive electrochemical detection of hydrazine and isoniazid in real samples. Black-Right-Pointing-Pointer An exemplary work of CME sensor assembly onto microchip for determination of analytes with environmental significance. Black-Right-Pointing-Pointer Manifestation of the applicability and flexibility of CME sensor for electroanalysis on microfluidic chip. - Abstract: Nanomaterial-based electrochemical sensor has received significant interest. In this work, cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode was electrochemically prepared and exploited as an amperometric detector for microchip electrophoresis. The prepared sensor displayed rapid and sensitive response towards hydrazine and isoniazid oxidation, which was attributed to synergetic electrocatalytic effect of cobalt hexacyanoferrate and multi-walled carbon nanotubes. The sensitivity enhancement with nearly two orders of magnitude was gained, compared with the bare carbon paste electrode, with the detection limit of 0.91 {mu}M (S/N = 3) for hydrazine. Acceptable repeatability of the microanalysis system was verified by consecutive eleven injections of hydrazine without chip and electrode treatments, the RSDs for peak current and migration time were 3.4% and 2.1%, respectively. Meanwhile, well-shaped electrophoretic peaks were observed, mainly due to fast electron transfer of electroactive species on the modified electrode. The developed microchip-electrochemistry setup was successfully applied to the determination of hydrazine and isoniazid in river water and pharmaceutical preparation, respectively. Several merits of the novel electrochemical sensor coupled with microfluidic platform, such as comparative stability, easy fabrication and

  13. Temperature dependence of annealing on the contact resistance of MoS2 with graphene electrodes observed

    Science.gov (United States)

    Lu, Qin; Fang, Cizhe; Liu, Yan; Shao, Yao; Han, Genquan; Zhang, Jincheng; Hao, Yue

    2018-04-01

    Two-dimensional (2D) materials are promising candidates for atomically thin nanoelectronics. Among them, MoS2 has attracted considerable attention in the nanoscience and nanotechnology community owing to its unique characteristics including high electron mobility and intrinsic band gap. In this study, we experimentally explored the contact resistances of MoS2 films based on much layered graphene films as electrodes using the circular transmission line model (CTLM). The variation in the chemical composition of the material is thoroughly analyzed by Raman and X-ray photoelectric spectroscopy (XPS) measurements. Experimental results demonstrate that annealing followed by oxygen plasma treatment can effectively improve the contact resistance. Furthermore, the current-voltage curves measured after different annealing temperatures indicate good linear characteristics, which means a marked improvement in electrical property. Calculations show that a relatively low contact resistance of ˜4.177 kΩ (ignoring its size) without back gate voltage in a single-layer graphene/MoS2 structure at an optimal annealing temperature of 500 °C is achieved. This work about the effect of annealing temperature on contact resistance can also be employed for other 2D materials, which lays a foundation for further development of novel 2D material devices.

  14. Gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode as a sensitive voltammetric sensor for the determination of diclofenac sodium.

    Science.gov (United States)

    Afkhami, Abbas; Bahiraei, Atousa; Madrakian, Tayyebeh

    2016-02-01

    A simple and highly sensitive sensor for the determination of diclofenac sodium based on gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode is reported. Scanning electron microscopy along with energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry was used to characterize the nanostructure and performance of the sensor and the results were compared with those obtained at the multi-walled carbon nanotube modified glassy carbon electrode and bare glassy carbon electrode. Under the optimized experimental conditions diclofenac sodium gave linear response over the range of 0.03-200μmolL(-1). The lower detection limits were found to be 0.02μmolL(-1). The effect of common interferences on the current response of DS was investigated. The practical application of the modified electrode was demonstrated by measuring the concentration of diclofenac sodium in urine and pharmaceutical samples. This revealed that the gold nanoparticle/multiwalled carbon nanotube modified glassy carbon electrode shows excellent analytical performance for the determination of diclofenac sodium in terms of a very low detection limit, high sensitivity, very good accuracy, repeatability and reproducibility. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Liquid and gel electrodes for transverse free flow electrophoresis

    Science.gov (United States)

    Jung, Byoungsok; Rose, Klint A; Shusteff, Maxim; Persat, Alexandre; Santiago, Juan

    2015-04-07

    The present invention provides a mechanism for separating or isolating charged particles under the influence of an electric field without metal electrodes being in direct contact with the sample solution. The metal electrodes normally in contact with the sample are replaced with high conductivity fluid electrodes situated parallel and adjacent to the sample. When the fluid electrodes transmit the electric field across the sample, particles within the sample migrate according to their electrophoretic mobility.

  16. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  17. Evaluation of indirect blood pressure monitoring in awake and anesthetized red-tailed hawks (Buteo jamaicensis): effects of cuff size, cuff placement, and monitoring equipment.

    Science.gov (United States)

    Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H

    2009-09-01

    To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.

  18. Skin denervation does not alter cortical potentials to surface concentric electrode stimulation: A comparison with laser evoked potentials and contact heat evoked potentials.

    Science.gov (United States)

    La Cesa, S; Di Stefano, G; Leone, C; Pepe, A; Galosi, E; Alu, F; Fasolino, A; Cruccu, G; Valeriani, M; Truini, A

    2018-01-01

    In the neurophysiological assessment of patients with neuropathic pain, laser evoked potentials (LEPs), contact heat evoked potentials (CHEPs) and the evoked potentials by the intraepidermal electrical stimulation via concentric needle electrode are widely agreed as nociceptive specific responses; conversely, the nociceptive specificity of evoked potentials by surface concentric electrode (SE-PREPs) is still debated. In this neurophysiological study we aimed at verifying the nociceptive specificity of SE-PREPs. We recorded LEPs, CHEPs and SE-PREPs in eleven healthy participants, before and after epidermal denervation produced by prolonged capsaicin application. We also used skin biopsy to verify the capsaicin-induced nociceptive nerve fibre loss in the epidermis. We found that whereas LEPs and CHEPs were suppressed after capsaicin-induced epidermal denervation, the surface concentric electrode stimulation of the same denervated skin area yielded unchanged SE-PREPs. The suppression of LEPs and CHEPs after nociceptive nerve fibre loss in the epidermis indicates that these techniques are selectively mediated by nociceptive system. Conversely, the lack of SE-PREP changes suggests that SE-PREPs do not provide selective information on nociceptive system function. Capsaicin-induced epidermal denervation abolishes laser evoked potentials (LEPs) and contact heat evoked potentials (CHEPs), but leaves unaffected pain-related evoked potentials by surface concentric electrode (SE-PREPs). These findings suggest that unlike LEPs and CHEPs, SE-PREPs are not selectively mediated by nociceptive system. © 2017 European Pain Federation - EFIC®.

  19. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II program we propose to develop a manufacturable production process to introduce backside contacts to MicroLink Devices? large-area, multi-junction...

  20. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I program we propose to develop an innovative fabrication process to introduce backside contacts to MicroLink Devices' large-area, multi-junction...

  1. Normal isometric strength of rotator cuff muscles in adults

    OpenAIRE

    Chezar, A.; Berkovitch, Y.; Haddad, M.; Keren, Y.; Soudry, M.; Rosenberg, N.

    2013-01-01

    Objectives The most prevalent disorders of the shoulder are related to the muscles of rotator cuff. In order to develop a mechanical method for the evaluation of the rotator cuff muscles, we created a database of isometric force generation by the rotator cuff muscles in normal adult population. We hypothesised the existence of variations according to age, gender and dominancy of limb. Methods A total of 400 healthy adult volunteers were tested, classified into groups of 50 men and women for e...

  2. Establishing Maximal Medical Improvement After Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Zuke, William A; Leroux, Timothy S; Gregory, Bonnie P; Black, Austin; Forsythe, Brian; Romeo, Anthony A; Verma, Nikhil N

    2018-03-01

    As health care transitions from a pay-for-service to a pay-for-performance infrastructure, the value of orthopaedic care must be defined accurately. Significant efforts have been made in defining quality and cost in arthroplasty; however, there remains a lag in ambulatory orthopaedic care. Two-year follow-up has been a general requirement for reporting outcomes after rotator cuff repair. However, this time requirement has not been established scientifically and is of increasing importance in the era of value-based health care. Given that arthroscopic rotator cuff repair is a common ambulatory orthopaedic procedure, the purpose of this study was to establish a time frame for maximal medical improvement (the state when improvement has stabilized) after arthroscopic rotator cuff repair. Systematic review. A systematic review of the literature was conducted, identifying studies reporting sequential patient-reported outcomes up to a minimum of 2 years after arthroscopic rotator cuff repair. The primary clinical outcome was patient-reported outcomes at 3-month, 6-month, 1-year, and 2-year follow-up. Secondary clinical outcomes included range of motion, strength, retears, and complications. Clinically significant improvement was determined between various time intervals by use of the minimal clinically important difference. The review included 19 studies including 1370 patients who underwent rotator cuff repair. Clinically significant improvement in patient-reported outcomes was seen up to 1 year after rotator cuff repair, but no clinical significance was noted from 1 year to 2 years. The majority of improvement in strength and range of motion was seen up to 6 months, but no clinically meaningful improvement was seen thereafter. All reported complications and the majority of retears occurred within 6 months after rotator cuff repair. After rotator cuff repair, a clinically significant improvement in patient-reported outcomes, range of motion, and strength was seen up to 1

  3. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    Directory of Open Access Journals (Sweden)

    Vishnumurthy H. Y

    2016-09-01

    Full Text Available INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS Thirty patients clinically suspected to have rotator cuff tear who underwent ultrasonography and arthroscopy of shoulder were included in the study. Duration of study was for two years. All ultrasonography examinations were conducted in ultrasound machine using GE Voluson 730 PRO high frequency (10-12 MHz linear array transducer done by two experienced radiologists. Arthroscopies were done by two experienced shoulder arthroscopic surgeons. RESULTS Age of the patients with rotator cuff tears ranged from 40 to 80 years. 57% were females and 43% were males among the patients who had rotator cuff tears. 71.43% of the rotator cuff tears were found in the dominant arm. 64.28% of patients with rotator cuff tear had given history of fall or trauma to the corresponding shoulder within 6 months prior to presentation. 39.28% of patients who had rotator cuff tears were known diabetics. Supraspinatus tendon was the most commonly affected tendon, followed by infraspinatus and subscapularis tendons. For overall detection of rotator cuff tears, ultrasonography in comparison with the arthroscopy has sensitivity and specificity of 92.85% and 100%. For detection of full thickness rotator cuff tear, its sensitivity and specificity was 94.73% and 100% and for partial thickness rotator cuff tears 76.92% and 100%. Ultrasonography has 100% sensitivity and specificity for detection of supraspinatus full thickness tear. For supraspinatus partial thickness tear, sensitivity and specificity was 88

  4. Contacts, non-linear transport effects and failure in multi-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Berger, C; Yi, Y; Gezo, J; Poncharal, P; Heer, W A de

    2003-01-01

    Pristine arc-produced multi-walled carbon nanotubes are contacted to liquid mercury in situ in a transmission electron microscope. The conductance G(V) for all tubes increases with increasing bias voltage V. This is related to the electronic density of the nanotubes. Similar G(V) behaviour is observed for HOPG-graphite contacted in air with Hg, with dG(V)/dV∼0.3G 0 . Variations observed in the conductance are related to nanotube-Hg contact effects. For tubes barely touching the Hg surface, the conductance is low (typically G(V=0)∼0.1-0.5G 0 ); G(V) may maximize around V=1.5-2 V or continue to increase linearly depending on the MWNT-Hg contact. For good contacts the maximum low-bias conductance is 1G 0 . Non-conducting tubes are observed having a low-bias conductance smaller than 10 -3 G 0 . High-voltage tube failure usually occurs at the contact with Hg for clean tubes, or at tube defects. An important phenomenon is the formation of a Hg bubble near the contact nanotube-Hg surface when the nanotube is negatively biased, under high bias current conditions, indicating the heating effect of hot electrons injected into the mercury

  5. Low-cost electrodes for stable perovskite solar cells

    Science.gov (United States)

    Bastos, João P.; Manghooli, Sara; Jaysankar, Manoj; Tait, Jeffrey G.; Qiu, Weiming; Gehlhaar, Robert; De Volder, Michael; Uytterhoeven, Griet; Poortmans, Jef; Paetzold, Ulrich W.

    2017-06-01

    Cost-effective production of perovskite solar cells on an industrial scale requires the utilization of exclusively inexpensive materials. However, to date, highly efficient and stable perovskite solar cells rely on expensive gold electrodes since other metal electrodes are known to cause degradation of the devices. Finding a low-cost electrode that can replace gold and ensure both efficiency and long-term stability is essential for the success of the perovskite-based solar cell technology. In this work, we systematically compare three types of electrode materials: multi-walled carbon nanotubes (MWCNTs), alternative metals (silver, aluminum, and copper), and transparent oxides [indium tin oxide (ITO)] in terms of efficiency, stability, and cost. We show that multi-walled carbon nanotubes are the only electrode that is both more cost-effective and stable than gold. Devices with multi-walled carbon nanotube electrodes present remarkable shelf-life stability, with no decrease in the efficiency even after 180 h of storage in 77% relative humidity (RH). Furthermore, we demonstrate the potential of devices with multi-walled carbon nanotube electrodes to achieve high efficiencies. These developments are an important step forward to mass produce perovskite photovoltaics in a commercially viable way.

  6. Rotator Cuff Disease and Injury--Evaluation and Management.

    Science.gov (United States)

    Williams, Randy

    This presentation considers the incidence, evaluation, and management of rotator cuff disease and injury. Pathogenesis, symptoms, physical findings, treatment (therapeutic and surgical), and prevention are discussed. It is noted that rotator cuff problems, common in athletes, are usually related to an error in training or lack of training. They…

  7. Clinical thermometry, using the 27 MHz multi-electrode current-source interstitial hyperthermia system in brain tumours

    International Nuclear Information System (INIS)

    Kaatee, Robert S.J.P.; Nowak, Peter C.J.M.; Zee, Jacoba van der; Bree, Jacob de; Kanis, Bart P.; Crezee, Hans; Levendag, Peter C.; Visser, Andries G.

    2001-01-01

    Background and purpose: In interstitial hyperthermia, temperature measurements are mainly performed inside heating applicators, and therefore, give the maximum temperatures of a rather heterogeneous temperature distribution. The problem of how to estimate lesion temperatures using the multi-electrode current-source interstitial hyperthermia (MECS-IHT) system in the brain was studied. Materials and methods: Temperatures were measured within the electrodes and in an extra catheter at the edge of a 4x4x4.5 cm 3 glioblastoma multiforme resection cavity. From the temperature decays during a power-off period, information was obtained about local maximum and minimum tissue temperatures. The significance of these data was examined through model calculations. Results: Maximum tissue temperatures could be estimated roughly by switching off all electrodes for about 5 s. Model calculations showed that the minimum tissue temperatures near a certain afterloading catheter correspond well with the temperature of the applicator inside, about 1 min after this applicator was switched off. Conclusions: Although the electrode temperatures read during heating are not suitable to assess the temperature distribution, it is feasible to heat the brain adequately using the MECS-IHT system with extra sensors outside the electrodes and/or application of decay methods

  8. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  9. Moving towards high-power, high-frequency and low-resistance CNT supercapacitors by tuning the CNT length, axial deformation and contact resistance

    Science.gov (United States)

    Basiricò, L.; Lanzara, G.

    2012-08-01

    In this paper it is shown that the electrochemical behaviour of vertically aligned multi-walled carbon nanotube (VANT) supercapacitors is influenced by the VANTs’ length (electrode thickness), by their axial compression and by their interface with the current collector. It is found that the VANTs, which can be interpreted as a dense array of nanochannels, have an active area available to ions that is strongly affected by the electrode’s thickness and compressional state. Consequently, the tested thinner electrodes, compressed electrodes or a combination of the two were found to be characterized by a significant improvement in terms of power density (up to 1246%), knee frequency (58 822% working up to 10 kHz), equivalent series resistance (ESR, up to 67%) and capacitance (up to 21%) when compared with thicker and/or uncompressed electrodes. These values are significantly higher than those reported in the literature where long VANTs with no control on compression are typically used. It is also shown that the ESR can be reduced not only by using shorter and compressed VANTs that have a higher conductance or by improving the electrode/collector electrical contact by changing the contact morphology at the nanoscale through compression, but also by depositing a thin platinum layer on the VANT tips in contact with the current collector (73% ESR decrease).

  10. Moving towards high-power, high-frequency and low-resistance CNT supercapacitors by tuning the CNT length, axial deformation and contact resistance

    International Nuclear Information System (INIS)

    Basiricò, L; Lanzara, G

    2012-01-01

    In this paper it is shown that the electrochemical behaviour of vertically aligned multi-walled carbon nanotube (VANT) supercapacitors is influenced by the VANTs’ length (electrode thickness), by their axial compression and by their interface with the current collector. It is found that the VANTs, which can be interpreted as a dense array of nanochannels, have an active area available to ions that is strongly affected by the electrode’s thickness and compressional state. Consequently, the tested thinner electrodes, compressed electrodes or a combination of the two were found to be characterized by a significant improvement in terms of power density (up to 1246%), knee frequency (58 822% working up to 10 kHz), equivalent series resistance (ESR, up to 67%) and capacitance (up to 21%) when compared with thicker and/or uncompressed electrodes. These values are significantly higher than those reported in the literature where long VANTs with no control on compression are typically used. It is also shown that the ESR can be reduced not only by using shorter and compressed VANTs that have a higher conductance or by improving the electrode/collector electrical contact by changing the contact morphology at the nanoscale through compression, but also by depositing a thin platinum layer on the VANT tips in contact with the current collector (73% ESR decrease). (paper)

  11. Evaluation of post-exercise magnetic resonance images of the rotator cuff

    International Nuclear Information System (INIS)

    Cahoy, P.M.; Orwin, J.F.; Tuite, M.J.

    1996-01-01

    Objective. To examine the effect of strenuous exercise on the magnetic resonance imaging (MRI) characteristics of the rotator cuff tendon. A second objective was to define an optimal time to image the rotator cuff and possibly eliminate exercise-induced false positives. Design and patients. Five male subjects from 24 to 38 years old with normal rotator cuffs by history, physical examination, and screening MRI underwent a rotator cuff exercise session on the Biodex System 2 (Biodex, Shirley, New York). The exercise sessions were followed by sequential MRI scans of the exercised shoulder. These were performed immediately and at 8 h and 24 h after exercise. Results and conclusions. The rotator cuff tendon and subacromial-subdeltoid bursal signal remained unchanged from the pre-exercise through the 24-h post-exercise scans. The rotator cuff muscle signal was increased in five of five subjects on the immediate post-exercise fat-suppressed T2-weighted images. This signal returned to baseline by the 8-h scan. Positive findings of rotator cuff pathology on MRI after strenuous athletic activity should not be discounted as normal exercise-induced changes. Also, diagnostic MRI scanning may take place after a practice session without an increased risk of false positives. (orig.). With 1 fig

  12. Evaluation of post-exercise magnetic resonance images of the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Cahoy, P M [Division of Orthopedic Surgery G5/358, University of Wisconsin Hospital and Clinics, Madison, WI (United States); Orwin, J F [Division of Orthopedic Surgery G5/358, University of Wisconsin Hospital and Clinics, Madison, WI (United States); Tuite, M J [Department of Radiology, University of Wisconsin Hospital and Clinics, Madison, WI (United States)

    1996-11-01

    Objective. To examine the effect of strenuous exercise on the magnetic resonance imaging (MRI) characteristics of the rotator cuff tendon. A second objective was to define an optimal time to image the rotator cuff and possibly eliminate exercise-induced false positives. Design and patients. Five male subjects from 24 to 38 years old with normal rotator cuffs by history, physical examination, and screening MRI underwent a rotator cuff exercise session on the Biodex System 2 (Biodex, Shirley, New York). The exercise sessions were followed by sequential MRI scans of the exercised shoulder. These were performed immediately and at 8 h and 24 h after exercise. Results and conclusions. The rotator cuff tendon and subacromial-subdeltoid bursal signal remained unchanged from the pre-exercise through the 24-h post-exercise scans. The rotator cuff muscle signal was increased in five of five subjects on the immediate post-exercise fat-suppressed T2-weighted images. This signal returned to baseline by the 8-h scan. Positive findings of rotator cuff pathology on MRI after strenuous athletic activity should not be discounted as normal exercise-induced changes. Also, diagnostic MRI scanning may take place after a practice session without an increased risk of false positives. (orig.). With 1 fig.

  13. Magnetic resonance imaging in acute and chronic rotator cuff tears

    International Nuclear Information System (INIS)

    Buirski, G.

    1990-01-01

    Magnetic resonance imaging has been assessed in patients with acute rotator cuff tears and normal radiographs (9 cases) and those with chronic tears and changes of cuff arthropathy (9 cases). All images were obtained using a low field strength system (FONAR 0.3 T). Particular attention was placed on the appearances of the tendon and the cuff muscles themselves. Six complete acute tears were clearly identified, but MRI failed to demonstrate two partial tears. Muscle bulk was preserved in all patients in this group. In contrast, all patients with cuff arthropathy had complete tears of the supraspinatus tendon with marked tendon retraction and associated muscle atrophy: These changes precluded primary surgical repair. MRI should be used to assess muscle atrophy preoperatively in those patients with acute tears. When plain radiographs demonstrate cuff arthropathy, the MRI appearances are predictable and primary repair is unlikely to be successful. Further imaging is therefore not indicated. (orig.)

  14. The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses.

    Directory of Open Access Journals (Sweden)

    Le Li

    Full Text Available This study investigates the impact of the subcutaneous fat layer (SFL thickness on localized electrical impedance myography (EIM, as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer longitudinal configuration 6.8 cm, narrow (or inner longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R2 of three EIM variables (resistance, reactance, and phase and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R2 = 0.0294, p = 0.434. Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM.

  15. Acromion Index in Korean Population and Its Relationship with Rotator Cuff Tears.

    Science.gov (United States)

    Kum, Dong Ho; Kim, Jun Ho; Park, Keun Min; Lee, Eun Su; Park, Yong Bok; Yoo, Jae Chul

    2017-06-01

    Among the many causes of rotator cuff tears, scapular morphology is associated with the accelerating degenerative process of the rotator cuff. Acromion index (AI) was previously introduced and compared in two populations. We enrolled 100 Korean patients diagnosed with full-thickness rotator cuff tears by magnetic resonance imaging and intraoperative arthroscopic findings between January and December 2013. Another 100 Korean patients with an intact rotator cuff tendon identified on magnetic resonance imaging and other shoulder diseases, such as frozen shoulder and instability, were enrolled as controls. We retrospectively compared these 100 rotator cuff tear patients (mean age, 63 years) and 100 controls (mean age, 51 years) in this study. Two independent orthopedic surgeons assessed the AI on radiographs. We performed an interobserver reliability test of the AI assessment, and then compared the AI between two groups. The measurement of the AI showed excellent reliability (intraclass correlation coefficient, 0.82). The mean AI in the rotator cuff tear group was 0.68 and it was significantly different between groups ( p rotator cuff tears in a Korean population.

  16. Multi-walled Carbon Nanotubes/Graphite Nanosheets Modified Glassy Carbon Electrode for the Simultaneous Determination of Acetaminophen and Dopamine.

    Science.gov (United States)

    Zhang, Susu; He, Ping; Zhang, Guangli; Lei, Wen; He, Huichao

    2015-01-01

    Graphite nanosheets prepared by thermal expansion and successive sonication were utilized for the construction of a multi-walled carbon nanotubes/graphite nanosheets based amperometric sensing platform to simultaneously determine acetaminophen and dopamine in the presence of ascorbic acid in physiological conditions. The synergistic effect of multi-walled carbon nanotubes and graphite nanosheets catalyzed the electrooxidation of acetaminophen and dopamine, leading to a remarkable potential difference up to 200 mV. The as-prepared modified electrode exhibited linear responses to acetaminophen and dopamine in the concentration ranges of 2.0 × 10(-6) - 2.4 × 10(-4) M (R = 0.999) and 2.0 × 10(-6) - 2.0 × 10(-4) M (R = 0.998), respectively. The detection limits were down to 2.3 × 10(-7) M for acetaminophen and 3.5 × 10(-7) M for dopamine (S/N = 3). Based on the simple preparation and prominent electrochemical properties, the obtained multi-walled carbon nanotubes/graphite nanosheets modified electrode would be a good candidate for the determination of acetaminophen and dopamine without the interference of ascorbic acid.

  17. Improved apparatus for predictive diagnosis of rotator cuff disease

    Science.gov (United States)

    Pillai, Anup; Hall, Brittany N.; Thigpen, Charles A.; Kwartowitz, David M.

    2014-03-01

    Rotator cuff disease impacts over 50% of the population over 60, with reports of incidence being as high as 90% within this population, causing pain and possible loss of function. The rotator cuff is composed of muscles and tendons that work in tandem to support the shoulder. Heavy use of these muscles can lead to rotator cuff tear, with the most common causes is age-related degeneration or sport injuries, both being a function of overuse. Tears ranges in severity from partial thickness tear to total rupture. Diagnostic techniques are based on physical assessment, detailed patient history, and medical imaging; primarily X-ray, MRI and ultrasonography are the chosen modalities for assessment. The final treatment technique and imaging modality; however, is chosen by the clinician is at their discretion. Ultrasound has been shown to have good accuracy for identification and measurement of full-thickness and partial-thickness rotator cuff tears. In this study, we report on the progress and improvement of our method of transduction and analysis of in situ measurement of rotator cuff biomechanics. We have improved the ability of the clinician to apply a uniform force to the underlying musculotendentious tissues while simultaneously obtaining the ultrasound image. This measurement protocol combined with region of interest (ROI) based image processing will help in developing a predictive diagnostic model for treatment of rotator cuff disease and help the clinicians choose the best treatment technique.

  18. Pulley lesions in rotator cuff tears: prevalence, etiology, and concomitant pathologies.

    Science.gov (United States)

    Hawi, Nael; Liodakis, Emmanouil; Garving, Christina; Habermeyer, Peter; Tauber, Mark

    2017-08-01

    This study aimed to demonstrate the prevalence of lesions in the biceps pulley complex in a representative, consecutive series of rotator cuff tears and rotator cuff interval treatments. We also analyzed associated tear pattern of rotator cuff injuries and superior labrum anterior-posterior (SLAP) lesions. We evaluated the relationships of these lesions to traumatic genesis and the prevalence of pulley lesions in revision cases. This retrospective study analyzed all pre- and intra-operative documentation on arthroscopic rotator cuff reconstructions and isolated pulley lesion treatments performed by a single surgeon over 2 consecutive years. According to Habermeyer et al., we classified cases into four groups, based on the presence of additional or related complete or partial rotator cuff tears, SLAP lesions, trauma, and primary or revision surgery. Among 382 patients with rotator cuff tears, 345 (90.3%) had an injured pulley system; 151 (43.8%) had partial tears of the rotator cuff; out of these, 106 (30.6%) were articular-sided. All of these articular-sided partial tears showed extension into the pulley complex. In 154 cases (44.6%), history of shoulder trauma was associated with the beginning of symptoms. In addition, concomitant SLAP lesions occurred in 25-62% of pulley lesions, correlating with the severity of pulley lesions. Among the 345 cases, there have been 32 (9.3%) revision cases where a pulley lesion was intra-operatively identified and addressed. Pulley complex lesions are present in 90.3% of surgically treated rotator cuff lesions, particularly in articular-sided injuries. In addition, we found a significant relationship between the incidence of SLAP lesions and the severity of pulley lesions. It seems reasonable to assume an important role of pulley system injuries in the pathogenesis of rotator cuff lesions.

  19. Bias dependent specic contact resistance of phase change material to metal contacts

    NARCIS (Netherlands)

    Roy, Deepu; in 't Zandt, Micha; Wolters, Robertus A.M.

    2010-01-01

    Knowledge of contact resistance of phase change materials (PCM) to metal electrodes is important for scaling, device modeling and optimization of phase change random access memory (PCRAM) cells. In this article, we report the systematic determination of the speci_c contact resistance (_c) with

  20. A novel perspective on the formation of the solid electrolyte interphase on the graphite electrode for lithium-ion batteries

    International Nuclear Information System (INIS)

    Yan Jian; Zhang Jian; Su Yuchang; Zhang Xigui; Xia Baojia

    2010-01-01

    In this paper, we describe how the mechanism of formation of a protective film [the solid electrolyte interphase (or interface) (SEI)] on a graphite electrode for Li-ion batteries was investigated from the novel perspective of precipitation of the final decomposition products that arise from the reduction of a nonaqueous electrolyte solution in contact with the graphite electrode. Within the framework of this new perspective, we can elegantly account for the compositional and structural differences between the basal-plane and edge-plane SEIs and for the origins of the multi-layer structure and the parabolic growth law of the SEIs on both the edge-plane and basal-plane surfaces of the graphite electrode.

  1. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport

    Directory of Open Access Journals (Sweden)

    Joseph Tennyson

    2016-11-01

    Full Text Available Introduction Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS transportation. Measurement of endotracheal tube (ETT cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH2O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH2O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. Methods We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. Results We analyzed data for 55 patients. There was a mean age of 57 years (range 18–90. The mean ETT cuff pressure was 70 (95% CI= [61–80] cmH2O. The mean lies 40 cmH2O above the maximum accepted value of 30 cmH2O (p120 cmH2O, the maximum pressure on the analog gauge. Conclusion Patients presenting to HEMS after intubation by the referral agency (EMS or hospital have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should use ETT cuff manometry to ensure that they inflate ETT cuffs to safe pressures.

  2. A uric acid sensor based on electrodeposition of nickel hexacyanoferrate nanoparticles on an electrode modified with multi-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Fang, B.; Feng, Y.; Wang, G.; Zhang, C.; Gu, A.; Liu, M.

    2011-01-01

    An electrode sensitive to uric acid was prepared by electrodeposition of nickel(II) hexacyanoferrate(III) on the surface of a glassy carbon electrode modified with multi-walled carbon nanotubes. The morphology of the material was characterized by scanning electron microscopy and Fourier transform infrared spectrometry. The modified electrode were characterized via cyclic voltammetry and amperometry (i - t). It exhibited efficient electron transfer ability and a strong and fast (< 3 s) response towards uric acid which is linear in the range from 0.1 μM to 18 μM, with a lower detection limit of 50 nM (at an S/N ratio of 3). In addition, the electrode exhibited good reproducibility and long-term stability. (author)

  3. Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction

    DEFF Research Database (Denmark)

    Knudsen, H B; Gelineck, J; Søjbjerg, Jens Ole

    1999-01-01

    The aim of this study was to investigate tendon integrity after surgical repair of single-tendon rotator cuff lesions. In 31 patients, 31 single-tendon repairs were evaluated. Thirty-one patients were available for clinical assessment and magnetic resonance imaging (MRI) at follow-up. A standard...... series of MR images was obtained for each. The results of functional assessment were scored according to the system of Constant. According to MRI evaluation, 21 (68%) patients had an intact or thinned rotator cuff and 10 (32%) had recurrence of a full-thickness cuff defect at follow-up. Patients...... with an intact or thinned rotator cuff had a median Constant score of 75.5 points; patients with a full-thickness cuff defect had a median score of 62 points. There was no correlation between tendon integrity on postoperative MR images and functional outcome. Patients with intact or thinned cuffs did not have...

  4. Oxidized multi walled carbon nanotubes for improving the electrocatalytic activity of a benzofuran derivative modified electrode

    Directory of Open Access Journals (Sweden)

    Mohammad Mazloum-Ardakani

    2016-01-01

    Full Text Available In the present paper, the use of a novel carbon paste electrode modified by 7,8-dihydroxy-3,3,6-trimethyl-3,4-dihydrodibenzo[b,d]furan-1(2H-one (DTD and oxidized multi-walled carbon nanotubes (OCNTs is described for determination of levodopa (LD, acetaminophen (AC and tryptophan (Trp by a simple and rapid method. At first, the electrochemical behavior of DTD is studied, then, the mediated oxidation of LD at the modified electrode is investigated. At the optimum pH of 7.4, the oxidation of LD occurs at a potential about 330 mV less positive than that of an unmodified carbon paste electrode. Based on differential pulse voltammetry (DPV, the oxidation current of LD exhibits a linear range between 1.0 and 2000.0 μM of LD with a detection limit (3σ of 0.36 μM. DPV was also used for simultaneous determination of LD, AC and Trp at the modified electrode. Finally, the proposed electrochemical sensor was used for determinations of these substances in human serum sample.

  5. Design, construction and mechanical optimisation process of electrode with radial current flow in the scala tympani.

    Science.gov (United States)

    Deman, P R; Kaiser, T M; Dirckx, J J; Offeciers, F E; Peeters, S A

    2003-09-30

    A 48 contact cochlear implant electrode has been constructed for electrical stimulation of the auditory nerve. The stimulating contacts of this electrode are organised in two layers: 31 contacts on the upper surface directed towards the habenula perforata and 17 contacts connected together as one longitudinal contact on the underside. The design of the electrode carrier aims to make radial current flow possible in the cochlea. The mechanical structure of the newly designed electrode was optimised to obtain maximal insertion depth. Electrode insertion tests were performed in a transparent acrylic model of the human cochlea.

  6. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness

    Science.gov (United States)

    Freeberg, M. J.; Stone, M. A.; Triolo, R. J.; Tyler, D. J.

    2017-06-01

    Objective. As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Approach. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite’s capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. Main Results. In vitro inflation tests showed effective CNRs (1.93  ±  0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly

  7. A solid-contact Pb2+-selective electrode using poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene) as ion-to-electron transducer

    International Nuclear Information System (INIS)

    Yu Shunyang; Li Fuhai; Yin Tanji; Liu Yongming; Pan, Dawei; Qin Wei

    2011-01-01

    Highlights: → All reagents used for the electrodes preparation were commercially available. → The lower detection limit of the proposed electrode reached subnanomolar levels. → No water film was observed with conventional commercially available PVC ion-sensing membranes. → This research provides an excellent strategy for fabrication of robust polymeric ion sensors. - Abstract: In this work, a novel all-solid-state polymeric membrane Pb 2+ -selective electrode was developed by using for the first time poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene) (MEH-PPV) as solid contact. To demonstrate the ion-to-electron transducing ability of MEH-PPV, chronopotentiometry and electrochemical impedance spectroscopy measurements were carried out. The proposed electrodes showed a Nernstian response of 29.1 mV decade -1 and a lower detection limit of subnanomolar level. No water film was observed with the conventional plasticized PVC membrane. This work demonstrates a new strategy for the fabrication of robust potentiometric ion sensors.

  8. Functional outcomes after bilateral arthroscopic rotator cuff repair.

    Science.gov (United States)

    Aleem, Alexander W; Syed, Usman Ali M; Wascher, Jocelyn; Zoga, Adam C; Close, Koby; Abboud, Joseph A; Cohen, Steven B

    2016-10-01

    Arthroscopic repair of rotator cuff tears is a common procedure performed by orthopedic surgeons. There is a well-known incidence of up to 35% of bilateral rotator cuff tear disease in patients who have a known unilateral tear. The majority of the literature focuses on outcomes after unilateral surgery. The purpose of this study was to determine if there are clinical differences in shoulders of patients who underwent staged bilateral rotator cuff repairs during their lifetime. A retrospective review of all patients who underwent staged bilateral arthroscopic rotator cuff surgery at our institution was performed. All patients had at least 2 years of follow-up. Clinical outcome scores including the American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation, and Rowe measures were obtained. A subset of patients returned for clinical and ultrasound evaluation performed by an independent fellowship-trained musculoskeletal radiologist. Overall, 110 shoulders in 55 patients, representing 68% of all eligible patients, participated. No clinical or statistical difference was found in any outcome measure. ASES scores averaged 86.5 (36.7-100) in the dominant shoulder compared with 89.6 (23.3-100) in the nondominant shoulder (P = .42). Ultrasound was available on 34 shoulders and showed complete healing rate of 88%. The shoulders with retearing of the rotator cuff (12%) demonstrated clinically relevant lower ASES scores (72.5) compared with shoulders with confirmed healed repairs (86.2; P = .2). Patients who undergo staged bilateral rotator cuff repair can expect to have similarly good clinical outcomes regardless of hand dominance or chronologic incidence with excellent healing rates in both shoulders. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. A multi-electrode and pre-deformed bilayer spring structure electrostatic attractive MEMS actuator with large stroke at low actuation voltage

    International Nuclear Information System (INIS)

    Hu, Fangrong; Li, Zhi; Xiong, Xianming; Niu, Junhao; Peng, Zhiyong; Qian, Yixian; Yao, Jun

    2012-01-01

    This paper presents a multi-electrode and pre-deformed bilayer spring structure electrostatic attractive microelectromechanical systems (MEMS) actuator; it has large stroke at relatively low actuation voltage. Generally, electrostatic-attractive-force-based actuators have small stroke due to the instability resulted from the electrostatic ‘pull-in’ phenomenon. However, in many applications, the electrostatic micro-actuator with large stroke at low voltage is more preferred. By introducing a multi-electrode and a pre-deformed bilayer spring structure, an electrostatic attractive MEMS actuator with large stroke at very low actuation voltage has been successfully demonstrated in this paper. The actuator contains a central plate with a size of 300 µm × 300 µm × 1.5 µm and it is supported by four L-shaped bilayer springs which are pre-deformed due to residual stresses. Each bilayer spring is simultaneously attracted by three adjacent fixed electrodes, and the factors affecting the electrostatic attractive force are analyzed by a finite element analysis method. The prototype of the actuator is fabricated by poly-multi-user-MEMS-process (PolyMUMP) and the static performance is tested using a white light interferometer. The measured stroke of the actuator reaches 2 µm at 13 V dc, and it shows a good agreement with the simulation. (paper)

  10. Assessment of musculoskeletal pain sensitivity and temporal summation by cuff pressure algometry

    DEFF Research Database (Denmark)

    Graven-Nielsen, Thomas; Vaegter, Henrik Bjarke; Finocchietti, Sara

    2015-01-01

    ) conditioned pain modulation (CPM) assessed by cuff algometry. The influences of age and gender were evaluated. On two different days, cuff pain threshold (cPPT), cuff pain tolerance (cPTT), and temporal summation of pain (TSP) by visual analogue scale scores to 10 repeated cuff stimulations at cPTT intensity......, as well as pressure pain threshold (PPT) with handheld pressure algometry were assessed in 136 healthy subjects. In one session cuff pain sensitivity was also assessed before and after the cold-pressor induced CPM. Good to excellent intraclass correlations (ICCs: 0.60 - 0.90) were demonstrated for manual.......05). TSP were increased in women compared with men (PCPM demonstrated as increased cPPT, cPTT and reduced TSP (P

  11. Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black

    Science.gov (United States)

    Desai, Sharanya Arcot; Rolston, John D.; Guo, Liang; Potter, Steve M.

    2010-01-01

    Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes. PMID:20485478

  12. Endotracheal tube cuff pressure management in adult critical care ...

    African Journals Online (AJOL)

    of respondents performed cuff pressure measurements every 6 - 12 hours; 32% reported ... effectively when performing ETT cuff pressure management, to reduce practice variance, ... questionnaires were distributed to professional nurses working in .... MOV, CPM and the palpation method.3 No advantage of CPM over.

  13. Current Biomechanical Concepts of Suture Bridge Repair Technique for Rotator Cuff Tear

    OpenAIRE

    Ming-Long Yeh; Chih-Kai Hong; Wei-Ren Su; I-Ming Jou; Cheng-Li Lin; Chii-Jen Lin

    2015-01-01

    Rotator cuff tears are one of the most common disorders of the shoulder and can have significant effects on daily activities as a result of pain, loss of motion and strength. The goal of rotator cuff repair is aimed at anatomic restoration of the rotator cuff tendon to reduce pain and improve the joint function. Recently, arthroscopic repair has been widely accepted for treatment of rotator cuff tears due to its equal or better results than those from open repair. In 2006, a...

  14. Analysis of deep brain stimulation electrode characteristics for neural recording

    Science.gov (United States)

    Kent, Alexander R.; Grill, Warren M.

    2014-08-01

    Objective. Closed-loop deep brain stimulation (DBS) systems have the potential to optimize treatment of movement disorders by enabling automatic adjustment of stimulation parameters based on a feedback signal. Evoked compound action potentials (ECAPs) and local field potentials (LFPs) recorded from the DBS electrode may serve as suitable closed-loop control signals. The objective of this study was to understand better the factors that influence ECAP and LFP recording, including the physical presence of the electrode, the geometrical dimensions of the electrode, and changes in the composition of the peri-electrode space across recording conditions. Approach. Coupled volume conductor-neuron models were used to calculate single-unit activity as well as ECAP responses and LFP activity from a population of model thalamic neurons. Main results. Comparing ECAPs and LFPs measured with and without the presence of the highly conductive recording contacts, we found that the presence of these contacts had a negligible effect on the magnitude of single-unit recordings, ECAPs (7% RMS difference between waveforms), and LFPs (5% change in signal magnitude). Spatial averaging across the contact surface decreased the ECAP magnitude in a phase-dependent manner (74% RMS difference), resulting from a differential effect of the contact on the contribution from nearby or distant elements, and decreased the LFP magnitude (25% change). Reductions in the electrode diameter or recording contact length increased signal energy and increased spatial sensitivity of single neuron recordings. Moreover, smaller diameter electrodes (500 µm) were more selective for recording from local cells over passing axons, with the opposite true for larger diameters (1500 µm). Changes in electrode dimensions had phase-dependent effects on ECAP characteristics, and generally had small effects on the LFP magnitude. ECAP signal energy and LFP magnitude decreased with tighter contact spacing (100 µm), compared to

  15. Free Biceps Tendon Autograft to Augment Arthroscopic Rotator Cuff Repair

    OpenAIRE

    Obma, Padraic R.

    2013-01-01

    Arthroscopic rotator cuff repairs have become the standard of treatment for all sizes of tears over the past several years. Current healing rates reported in the literature are quite good, but improving the healing potential of rotator cuff repairs remains a challenging problem. There has been an increase recently in the use of augmentation of rotator cuff repairs with xenografts or synthetics for large and massive tears. Biceps tenodesis is often indicated as part of the treatment plan while...

  16. Natural History of Rotator Cuff Disease and Implications on Management

    Science.gov (United States)

    Hsu, Jason

    2015-01-01

    Degenerative rotator cuff disease is commonly associated with ageing and is often asymptomatic. The factors related to tear progression and pain development are just now being defined through longitudinal natural history studies. The majority of studies that follow conservatively treated painful cuff tears or asymptomatic tears that are monitored at regular intervals show slow progression of tear enlargement and muscle degeneration over time. These studies have highlighted greater risks for disease progression for certain variables, such as the presence of a full-thickness tear and involvement of the anterior aspect supraspinatus tendon. Coupling the knowledge of the natural history of degenerative cuff tear progression with variables associated with greater likelihood of successful tendon healing following surgery will allow better refinement of surgical indications for rotator cuff disease. In addition, natural history studies may better define the risks of nonoperative treatment over time. This article will review pertinent literature regarding degenerative rotator cuff disease with emphasis on variables important to defining appropriate initial treatments and refining surgical indications. PMID:26726288

  17. The effect of glenoid cavity depth on rotator cuff tendinitis.

    Science.gov (United States)

    Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Sever, Cem; Kara, Adna; Mahirogulları, Mahir

    2016-03-01

    Some of the most important causes of shoulder pain are inflammation and degenerative changes in the rotator cuff (RC). Magnetic resonance imaging (MRI) is a noninvasive and safe imaging modality. MRI can be used for the evaluation of cuff tendinopathy. In this study, we evaluated the relationship between glenoid cavity depth and cuff tendinopathy and we investigated glenoid cavity depth on the pathogenesis of cuff tendinopathy. We retrospectively evaluated 215 patients who underwent MRI. Of these, 60 patients showed cuff tendinopathy (group A) and 54 patients showed no pathology (group B). Glenoid cavity depth was calculated in the coronal and transverse planes. The mean axial depth was 1.7 ± 0.9 and the mean coronal depth 3.8 ± 0.9, for group A. The mean axial depth was 3.5 ± 0.7 and the mean coronal depth 1.5 ± 0.8, for group B. There were significant differences in the axial and coronal depths between the two groups. High coronal and low axial depth of the glenoid cavity can be used to diagnose RC tendinitis.

  18. Ultrasound-Guided Prolotherapy with Polydeoxyribonucleotide for Painful Rotator Cuff Tendinopathy

    Directory of Open Access Journals (Sweden)

    Kyoungho Ryu

    2018-01-01

    Full Text Available Background. Rotator cuff tendinopathy is a primary cause of shoulder pain and dysfunction. Several effective nonsurgical treatment methods have been described for chronic rotator cuff tendinopathy. Prolotherapy with polydeoxyribonucleotide (PDRN, which consists of active deoxyribonucleotide polymers that stimulate tissue repair, is a nonsurgical regenerative injection that may be a viable treatment option. The objective of this study was to assess the efficacy of PDRN in the treatment of chronic rotator cuff tendinopathy. Method. The records of patients with chronic rotator cuff tendinopathy (n=131 were reviewed retrospectively, and the patients treated with PDRN prolotherapy (n=32 were selected. We measured the main outcome of the shoulder pain and disability index score on a numerical rating scale of average shoulder pain. Results. Compared with baseline data, significant improvements in the shoulder pain and disability index and pain visual analog scale scores were demonstrated at one week after the end of treatment, and at one month and three months later. Conclusions. PDRN prolotherapy may improve the conservative treatment of painful rotator cuff tendinopathy for a specific subset of patients.

  19. Shouldering the blame for impingement: the rotator cuff continuum ...

    African Journals Online (AJOL)

    The aim of this article was to summarise recent research on shoulder impingement and rotator cuff pathology. A continuum model of rotator cuff pathology is described, and the challenges of accurate clinical diagnosis, imaging and best management discussed. Keywords: shoulder impingement syndrome, subacromial ...

  20. Identification of a genetic variant associated with rotator cuff repair healing.

    Science.gov (United States)

    Tashjian, Robert Z; Granger, Erin K; Zhang, Yue; Teerlink, Craig C; Cannon-Albright, Lisa A

    2016-06-01

    A familial and genetic predisposition for the development of rotator cuff tearing has been identified. The purpose of this study was to determine if a familial predisposition exists for healing after rotator cuff repair and if the reported significant association with a single-nucleotide polymorphism (SNP) in the ESRRB gene is present in patients who fail to heal. The study recruited 72 patients undergoing arthroscopic rotator cuff repair for a full-thickness posterosuperior tear. Magnetic resonance imaging studies were performed at a minimum of 1 year postoperatively (average, 2.6 years). Healing failures were classified as lateral or medial. Self-reported family history of rotator cuff tearing data and genome-wide genotypes were available. Characteristics of cases with and without a family history of rotator cuff tearing were compared, and a comparison of the frequency of SNP 1758384 (in ESRRB) was performed between patients who healed and those who failed to heal. Of the rotator cuff repairs, 42% failed to heal; 42% of patients reported a family history of rotator cuff tear. Multivariate regression analysis showed a significant association between familiality and overall healing failure (medial and lateral failures) (P = .036) and lateral failures independently (P = .006). An increased risk for the presence of a rare allele for SNP rs17583842 was present in lateral failures compared with those that healed (P = .005). Individuals with a family history of rotator cuff tearing were more likely to have repair failures. Significant association of a SNP variant in the ESRRB gene was also observed with lateral failure. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  2. NMR of the rotator cuff. An update; MRT der Rotatorenmanschette. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, Karl-Friedrich; Maehringer-Kunz, Aline [Universitaetsmedizin Mainz (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2016-03-15

    The rotator cuff consists of the tendons of the supscapularis, supraspinatus, infraspinatus and teres minor muscles. This group of muscles performs multiple functions and is often stressed during various activities. This explains, why rotator cuff disease is common and the most often cause of shoulder pain and dysfunction in adults. MR imaging still is the most important imaging modality in assessment of rotator cuff disease. It enables the radiologist to make an accurate diagnosis, the basis for an appropriate management. In this article, current concepts with regard to anatomy and imaging diagnosis will be reviewed. The discussion of the complex anatomy is followed by normal and pathologic MR imaging appearances of the rotator cuff including tendinopathy and tearing, and concluding with a review of the postoperative cuff.

  3. Ultra-low noise miniaturized neural amplifier with hardware averaging.

    Science.gov (United States)

    Dweiri, Yazan M; Eggers, Thomas; McCallum, Grant; Durand, Dominique M

    2015-08-01

    Peripheral nerves carry neural signals that could be used to control hybrid bionic systems. Cuff electrodes provide a robust and stable interface but the recorded signal amplitude is small (concept of hardware averaging to nerve recordings obtained with cuff electrodes. An optimization procedure is developed to minimize noise and power simultaneously. The novel design was based on existing neural amplifiers (Intan Technologies, LLC) and is validated with signals obtained from the FINE in chronic dog experiments. We showed that hardware averaging leads to a reduction in the total recording noise by a factor of 1/√N or less depending on the source resistance. Chronic recording of physiological activity with FINE using the presented design showed significant improvement on the recorded baseline noise with at least two parallel operation transconductance amplifiers leading to a 46.1% reduction at N = 8. The functionality of these recordings was quantified by the SNR improvement and shown to be significant for N = 3 or more. The present design was shown to be capable of generating hardware averaging on noise improvement for neural recording with cuff electrodes, and can accommodate the presence of high source impedances that are associated with the miniaturized contacts and the high channel count in electrode arrays. This technique can be adopted for other applications where miniaturized and implantable multichannel acquisition systems with ultra-low noise and low power are required.

  4. Immobilization After Rotator Cuff Repair: What Evidence Do We Have Now?

    Science.gov (United States)

    Hsu, Jason E; Horneff, John G; Gee, Albert O

    2016-01-01

    Recurrent tears after rotator cuff repair are common. Postoperative rehabilitation after rotator cuff repair is a modifiable factor controlled by the surgeon that can affect re-tear rates. Some surgeons prefer early mobilization after rotator cuff repair, whereas others prefer a period of immobilization to protect the repair site. The tendon-healing process incorporates biochemical and biomechanical responses to mechanical loading. Healing can be optimized with controlled loading. Complete load removal and chronic overload can be deleterious to the process. Several randomized clinical studies have also characterized the role of postoperative mobilization after rotator cuff repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Analysis of dynamic autoregulation assessed by the cuff deflation method.

    Science.gov (United States)

    Hlatky, Roman; Valadka, Alex B; Robertson, Claudia S

    2006-01-01

    Dynamic testing of cerebral pressure autoregulation is more practical than static testing for critically ill patients. The process of cuff deflation is innocuous in the normal subject, but the systemic and cerebral effects of cuff deflation in severely head-injured patients have not been studied. The purposes of this study were to examine the physiological effects of cuff deflation and to study their impact on the calculation of autoregulatory index (ARI). In 24 severely head-injured patients, 388 thigh cuff deflations were analyzed. The physiological parameters were recorded before, during, and after a transient decrease in blood pressure. Autoregulation was graded by generating an ARI value from 0 to 9. Mean arterial blood pressure (MAP) dropped rapidly during the first 2-3 seconds, but the nadir MAP was not reached until 8 +/- 7 seconds after the cuff deflation. MAP decreased by an average value of 19 +/- 5 mmHg. Initially the tracings for MAP and cerebral perfusion pressure (CPP) were nearly identical, but after 30 seconds, variable increases in intracranial pressure caused some differences between the MAP and CPP curves. The difference between the ARI values calculated twice using MAP as well as CPP was zero for 70% of left-sided studies and 73% for right-sided studies and less than or equal to 1 for 93% of left- and 95% of right-sided cuff deflations. Transient and relatively minor perturbations were detected in systemic physiology induced by dynamic testing of cerebral pressure autoregulation. Furthermore, this study confirms that the early changes in MAP and CPP after cuff deflation are nearly identical. MAP can substitute for CPP in the calculation of ARI even in the severely brain-injured patient.

  6. Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries

    Science.gov (United States)

    Wang, Xi; Gkogkidis, C. Alexis; Iljina, Olga; Fiederer, Lukas D. J.; Henle, Christian; Mader, Irina; Kaminsky, Jan; Stieglitz, Thomas; Gierthmuehlen, Mortimer; Ball, Tonio

    2017-10-01

    Objective. Innovations in micro-electrocorticography (µECoG) electrode array manufacturing now allow for intricate designs with smaller contact diameters and/or pitch (i.e. inter-contact distance) down to the sub-mm range. The aims of the present study were: (i) to investigate whether frequency ranges up to 400 Hz can be reproducibly observed in µECoG recordings and (ii) to examine how differences in topographical substructure between these frequency bands and electrode array geometries can be quantified. We also investigated, for the first time, the influence of blood vessels on signal properties and assessed the influence of cortical vasculature on topographic mapping. Approach. The present study employed two µECoG electrode arrays with different contact diameters and inter-contact distances, which were used to characterize neural activity from the somatosensory cortex of minipigs in a broad frequency range up to 400 Hz. The analysed neural data were recorded in acute experiments under anaesthesia during peripheral electrical stimulation. Main results. We observed that µECoG recordings reliably revealed multi-focal cortical somatosensory response patterns, in which response peaks were often less than 1 cm apart and would thus not have been resolvable with conventional ECoG. The response patterns differed by stimulation site and intensity, they were distinct for different frequency bands, and the results of functional mapping proved independent of cortical vascular. Our analysis of different frequency bands exhibited differences in the number of activation peaks in topographical substructures. Notably, signal strength and signal-to-noise ratios differed between the two electrode arrays, possibly due to their different sensitivity for variations in spatial patterns and signal strengths. Significance. Our findings that the geometry of µECoG electrode arrays can strongly influence their recording performance can help to make informed decisions that maybe

  7. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Bryan G. Vopat

    2014-05-01

    Full Text Available Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthro- scopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author’s practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001. This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  8. Muscle gene expression patterns in human rotator cuff pathology.

    Science.gov (United States)

    Choo, Alexander; McCarthy, Meagan; Pichika, Rajeswari; Sato, Eugene J; Lieber, Richard L; Schenk, Simon; Lane, John G; Ward, Samuel R

    2014-09-17

    Rotator cuff pathology is a common source of shoulder pain with variable etiology and pathoanatomical characteristics. Pathological processes of fatty infiltration, muscle atrophy, and fibrosis have all been invoked as causes for poor outcomes after rotator cuff tear repair. The aims of this study were to measure the expression of key genes associated with adipogenesis, myogenesis, and fibrosis in human rotator cuff muscle after injury and to compare the expression among groups of patients with varied severities of rotator cuff pathology. Biopsies of the supraspinatus muscle were obtained arthroscopically from twenty-seven patients in the following operative groups: bursitis (n = 10), tendinopathy (n = 7), full-thickness rotator cuff tear (n = 8), and massive rotator cuff tear (n = 2). Quantitative polymerase chain reaction (qPCR) was performed to characterize gene expression pathways involved in myogenesis, adipogenesis, and fibrosis. Patients with a massive tear demonstrated downregulation of the fibrogenic, adipogenic, and myogenic genes, indicating that the muscle was not in a state of active change and may have difficulty responding to stimuli. Patients with a full-thickness tear showed upregulation of fibrotic and adipogenic genes; at the tissue level, these correspond to the pathologies most detrimental to outcomes of surgical repair. Patients with bursitis or tendinopathy still expressed myogenic genes, indicating that the muscle may be attempting to accommodate the mechanical deficiencies induced by the tendon tear. Gene expression in human rotator cuff muscles varied according to tendon injury severity. Patients with bursitis and tendinopathy appeared to be expressing pro-myogenic genes, whereas patients with a full-thickness tear were expressing genes associated with fatty atrophy and fibrosis. In contrast, patients with a massive tear appeared to have downregulation of all gene programs except inhibition of myogenesis. These data highlight the

  9. The influence of simulated rotator cuff tears on the risk for impingement in handbike and handrim wheelchair propulsion.

    Science.gov (United States)

    van Drongelen, Stefan; Schlüssel, Matthias; Arnet, Ursina; Veeger, Dirkjan

    2013-06-01

    Rotator cuff tears strongly affect the biomechanics of the shoulder joint in their role to regulate the joint contact force needed to prevent the joint from dislocation. The aim of this study was to investigate the influence of simulated progressed rotator cuff tears on the (in)stability of the glenohumeral joint and the risk for impingement during wheelchair and handbike propulsion. The Delft Shoulder and Elbow Model was used to calculate the magnitude of the glenohumeral joint reaction force and the objective function J, which is an indication of the effort needed to complete the task. Full-thickness tears were simulated by virtually removing muscles from the model. With larger cuff tears the joint reaction force was higher and more superiorly directed. Also extra muscle force was necessary to balance the external force such that the glenohumeral joint did not dislocate. A tear of only the supraspinatus leads only to a minor increase in muscle forces and a minor shift of the force on the glenoid, indicating that it is possible to function well with a torn supraspinatus muscle. A massive tear shifts the direction of the joint reaction force to the superior border of the glenoid, increasing the risk for impingement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. An Investigation of Groundwater Flow on a Coastal Barrier using Multi Electrode Profiling

    DEFF Research Database (Denmark)

    Poulsen, Søren Erbs; Christensen, Steen; Rasmussen, Keld Rømer

    2008-01-01

    Preliminary geophysical and hydrogeological investigations indicate that multi-electrode profiling (MEP) can be used to monitor groundwater salinity on a coastal barrier where a shallow thin aquifer discharges to the North Sea. A monitoring system including five groups of piezometers and five MEP...... groundwater modeling we hope to be able to quantify how time varying recharge, tides, and storms hitting the barrier affect groundwater flow and discharge to the sea. At the conference we will present monitoring results from the winter and spring 2008....

  11. Self-discharge synchronizing operations in the external electrode fluorescent multi-lamps backlight

    International Nuclear Information System (INIS)

    Cho, Guangsup; Kwon, Nam O; Kim, Young M; Kim, Sung J; Cho, Tae S; Kim, Bong S; Kang, June G; Choi, Eun H; Lee, Ung W; Yang, Soon C; Uhm, Han S

    2003-01-01

    The external electrode fluorescent lamp (EEFL) is operated in a high frequency mode because the lamp lighting is basically a dielectric barrier discharge. The self-discharge synchronization is defined by synchronizing the self-discharge time of the dielectric wall charge with the voltage rising and falling time. It is shown that for the self-discharge synchronization a high brightness is obtained in the multi-lamps backlight connected in parallel with the EEFLs operated with square waves from a switching inverter. The frequency for self-discharge synchronizing is also shown to increase as the driving voltage increases

  12. Rotator Cuff Injuries.

    Science.gov (United States)

    Connors, G. Patrick

    Many baseball players suffer from shoulder injuries related to the rotator cuff muscles. These injuries may be classified as muscular strain, tendonitis or tenosynovitis, and impingement syndrome. Treatment varies from simple rest to surgery, so it is important to be seen by a physician as soon as possible. In order to prevent these injuries, the…

  13. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    OpenAIRE

    Vishnumurthy H. Y; Jagdeesh K. S; Anand K; Ranoji Mane; Sanath G. Kamte; Fathima Zohra; Banerji B. H; Sathish Servegar

    2016-01-01

    INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS...

  14. Problems of rotator cuff re-tear cases. Examination of operative findings

    International Nuclear Information System (INIS)

    Ishitani, Eiichi; Matsuura, Komei; Shin, Kunichika; Kawamoto, Taisaku; Hosokawa, Akira

    2007-01-01

    High re-tear rate is reported after rotator cuff repair in large and massive tear cases. Previously, we reported that 15% of patients after rotator cuff repair showed re-tear in MRI findings. In this study, 116 consecutive rotator cuff repaired patients who had been operated arthroscopically since 2003 were evaluated for size, torn site, fixation methods, mobility, and tendon quality. In addition, rehabilitation methods and occupation after revision were also evaluated. There were four patients who underwent re-operation. Rotator cuff repairs by revision surgery failed mechanically due to two reasons: the main factor of failure was suture material breakage in three cases and the second was tendon pulling through sutures in one case. The lack of thread strength was suggested. In addition, it is important to pull cuff stump to greater tubercle without excessive tension. Of re-operated cases, three engaging in manual labor suffered large and massive tear. In two cases, premature return to manual labor suggested cause of re-tear. (author)

  15. Differences in Risk Factors for Rotator Cuff Tears between Elderly Patients and Young Patients.

    Science.gov (United States)

    Watanabe, Akihisa; Ono, Qana; Nishigami, Tomohiko; Hirooka, Takahiko; Machida, Hirohisa

    2018-02-01

    It has been unclear whether the risk factors for rotator cuff tears are the same at all ages or differ between young and older populations. In this study, we examined the risk factors for rotator cuff tears using classification and regression tree analysis as methods of nonlinear regression analysis. There were 65 patients in the rotator cuff tears group and 45 patients in the intact rotator cuff group. Classification and regression tree analysis was performed to predict rotator cuff tears. The target factor was rotator cuff tears; explanatory variables were age, sex, trauma, and critical shoulder angle≥35°. In the results of classification and regression tree analysis, the tree was divided at age 64. For patients aged≥64, the tree was divided at trauma. For patients agedrotator cuff tears in this study. However, these risk factors showed different trends according to age group, not a linear relationship.

  16. Comorbidities in rotator cuff disease: a case-control study.

    Science.gov (United States)

    Titchener, Andrew G; White, Jonathan J E; Hinchliffe, Sally R; Tambe, Amol A; Hubbard, Richard B; Clark, David I

    2014-09-01

    Rotator cuff disease is a common condition in the general population, but relatively little is known about its associated risk factors. We have undertaken a large case-control study using The Health Improvement Network database to assess and to quantify the relative contributions of some constitutional and environmental risk factors for rotator cuff disease in the community. Our data set included 5000 patients with rotator cuff disease who were individually matched with a single control by age, sex, and general practice (primary care practice). The median age at diagnosis was 55 years (interquartile range, 44-65 years). Multivariate analysis showed that the risk factors associated with rotator cuff disease were Achilles tendinitis (odds ratio [OR] = 1.78), trigger finger (OR = 1.99), lateral epicondylitis (OR = 1.71), and carpal tunnel syndrome (OR = 1.55). Oral corticosteroid therapy (OR = 2.03), oral antidiabetic use (OR = 1.66), insulin use (OR = 1.77), and "overweight" body mass index of 25.1 to 30 (OR = 1.15) were also significantly associated. Current or previous smoking history, body mass index of greater than 30, any alcohol intake, medial epicondylitis, de Quervain syndrome, cubital tunnel syndrome, and rheumatoid arthritis were not found to be associated with rotator cuff disease. We have identified a number of comorbidities and risk factors for rotator cuff disease. These include lateral epicondylitis, carpal tunnel syndrome, trigger finger, Achilles tendinitis, oral corticosteroid use, and diabetes mellitus. The findings should alert the clinician to comorbid pathologic processes and guide future research into the etiology of this condition. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. The Biomechanical Role of Scaffolds in Augmented Rotator Cuff Tendon Repairs

    Science.gov (United States)

    2012-01-01

    The biomechanical role of scaffolds in augmented rotator cuff tendon repairs Amit Aurora, D Enga,b, Jesse A. McCarron, MDc, Antonie J. van den Bogert...used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving...The model predicts that the biomechanical performance of a rotator cuff repair can be modestly increased by augmenting the repair with a scaffold that

  18. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    Science.gov (United States)

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Comparison of endotracheal tube cuff pressure values before and after training seminar.

    Science.gov (United States)

    Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa

    2018-06-01

    It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p values decreased, however no statistically significant different was found (p values and potential complications.

  20. Electrocatalysis of oxygen reduction on nitrogen-containing multi-walled carbon nanotube modified glassy carbon electrodes

    International Nuclear Information System (INIS)

    Vikkisk, Merilin; Kruusenberg, Ivar; Joost, Urmas; Shulga, Eugene; Tammeveski, Kaido

    2013-01-01

    Highlights: ► Pyrolysis in the presence of urea was used for nitrogen doping of carbon nanotubes. ► N-doped carbon nanotubes were used as catalysts for the oxygen reduction reaction. ► N-doped carbon material showed a high catalytic activity for ORR in alkaline media. ► N-containing CNT material is an attractive cathode catalyst for alkaline membrane fuel cells. - Abstract: The electrochemical reduction of oxygen was studied on nitrogen-doped multi-walled carbon nanotube (NCNT) modified glassy carbon (GC) electrodes employing the rotating disk electrode (RDE) method. Nitrogen doping was achieved by simple pyrolysis of the carbon nanotube material in the presence of urea. The surface morphology and composition of the NCNT samples were investigated by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The SEM images revealed a rather uniform distribution of NCNTs on the GC electrode substrate. The XPS analysis showed a successful doping of carbon nanotubes with nitrogen species. The RDE results revealed that in alkaline solution the N-doped nanotube materials showed a remarkable electrocatalytic activity towards oxygen reduction. At low overpotentials the reduction of oxygen followed a two-electron pathway on undoped carbon nanotube modified GC electrodes, whereas on NCNT/GC electrodes a four-electron pathway of O 2 reduction predominated. The results obtained are significant for the development of nitrogen-doped carbon-based cathodes for alkaline membrane fuel cells.

  1. Modified suture-bridge technique to prevent a marginal dog-ear deformity improves structural integrity after rotator cuff repair.

    Science.gov (United States)

    Ryu, Keun Jung; Kim, Bang Hyun; Lee, Yohan; Lee, Yoon Seok; Kim, Jae Hwa

    2015-03-01

    The arthroscopic suture-bridge technique has proved to provide biomechanically firm fixation of the torn rotator cuff to the tuberosity by increasing the footprint contact area and pressure. However, a marginal dog-ear deformity is encountered not infrequently when this technique is used, impeding full restoration of the torn cuff. To evaluate the structural and functional outcomes of the use of a modified suture-bridge technique to prevent a marginal dog-ear deformity compared with a conventional suture-bridge method in rotator cuff repair. Cohort study; Level of evidence 2. A consecutive series of 71 patients aged 50 to 65 years who underwent arthroscopic rotator cuff repair for full-thickness medium-sized to massive tears was evaluated. Patients were divided into 2 groups according to repair technique: a conventional suture-bridge technique (34 patients; group A) versus a modified suture-bridge technique to prevent a marginal dog-ear deformity (37 patients; group B). Radiographic evaluations included postoperative cuff integrity using MRI. Functional evaluations included pre- and postoperative range of motion (ROM), pain visual analog scale (VAS), the University of California, Los Angeles (UCLA) shoulder rating scale, the Constant score, and the American Shoulder and Elbow Surgeons (ASES) score. All patients were followed up clinically at a minimum of 1 year. When the 2 surgical techniques were compared, postoperative structural integrity by Sugaya classification showed the distribution of types I:II:III:IV:V to be 4:20:2:4:4 in group A and 20:12:4:0:1 in group B. More subjects in group B had a favorable Sugaya type compared with group A (P bridge technique repairs were found in the retear group (P = .03). There were significant differences between healed and retear groups in functional outcome scores, with worse results in the retear group. A modified suture-bridge technique to prevent a marginal dog-ear deformity provided better structural outcomes than a

  2. Ultraconformable Temporary Tattoo Electrodes for Electrophysiology

    Science.gov (United States)

    Ferrari, Laura M.; Sudha, Sudha; Tarantino, Sergio; Esposti, Roberto; Bolzoni, Francesco; Cavallari, Paolo; Cipriani, Christian

    2018-01-01

    Abstract Electrically interfacing the skin for monitoring personal health condition is the basis of skin‐contact electrophysiology. In the clinical practice the use of stiff and bulky pregelled or dry electrodes, in contrast to the soft body tissues, imposes severe restrictions to user comfort and mobility while limiting clinical applications. Here, in this work dry, unperceivable temporary tattoo electrodes are presented. Customized single or multielectrode arrays are readily fabricated by inkjet printing of conducting polymer onto commercial decal transfer paper, which allows for easy transfer on the user's skin. Conformal adhesion to the skin is provided thanks to their ultralow thickness (Tattoo electrode–skin contact impedance is characterized on short‐ (1 h) and long‐term (48 h) and compared with standard pregelled and dry electrodes. The viability in electrophysiology is validated by surface electromyography and electrocardiography recordings on various locations on limbs and face. A novel concept of tattoo as perforable skin‐contact electrode, through which hairs can grow, is demonstrated, thus permitting to envision very long‐term recordings on areas with high hair density. The proposed materials and patterning strategy make this technology amenable for large‐scale production of low‐cost sensing devices. PMID:29593975

  3. Gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode as a sensitive voltammetric sensor for the determination of diclofenac sodium

    International Nuclear Information System (INIS)

    Afkhami, Abbas; Bahiraei, Atousa; Madrakian, Tayyebeh

    2016-01-01

    A simple and highly sensitive sensor for the determination of diclofenac sodium based on gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode is reported. Scanning electron microscopy along with energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry was used to characterize the nanostructure and performance of the sensor and the results were compared with those obtained at the multi-walled carbon nanotube modified glassy carbon electrode and bare glassy carbon electrode. Under the optimized experimental conditions diclofenac sodium gave linear response over the range of 0.03–200 μmol L −1 . The lower detection limits were found to be 0.02 μmol L −1 . The effect of common interferences on the current response of DS was investigated. The practical application of the modified electrode was demonstrated by measuring the concentration of diclofenac sodium in urine and pharmaceutical samples. This revealed that the gold nanoparticle/multiwalled carbon nanotube modified glassy carbon electrode shows excellent analytical performance for the determination of diclofenac sodium in terms of a very low detection limit, high sensitivity, very good accuracy, repeatability and reproducibility. - Highlights: • GCE was modified with multiwalled carbon nanotube and gold nanoparticles. • AuNP/MWCNT/GCE was used for the determination of diclofenac sodium. • Modified electrode was characterized by SEM, EDS and EIS. • The proposed method showed excellent analytical figures of merit. • This sensor was used for the determination of diclofenac sodium in real samples.

  4. Gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode as a sensitive voltammetric sensor for the determination of diclofenac sodium

    Energy Technology Data Exchange (ETDEWEB)

    Afkhami, Abbas, E-mail: afkhami@basu.ac.ir; Bahiraei, Atousa; Madrakian, Tayyebeh

    2016-02-01

    A simple and highly sensitive sensor for the determination of diclofenac sodium based on gold nanoparticle/multi-walled carbon nanotube modified glassy carbon electrode is reported. Scanning electron microscopy along with energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry was used to characterize the nanostructure and performance of the sensor and the results were compared with those obtained at the multi-walled carbon nanotube modified glassy carbon electrode and bare glassy carbon electrode. Under the optimized experimental conditions diclofenac sodium gave linear response over the range of 0.03–200 μmol L{sup −1}. The lower detection limits were found to be 0.02 μmol L{sup −1}. The effect of common interferences on the current response of DS was investigated. The practical application of the modified electrode was demonstrated by measuring the concentration of diclofenac sodium in urine and pharmaceutical samples. This revealed that the gold nanoparticle/multiwalled carbon nanotube modified glassy carbon electrode shows excellent analytical performance for the determination of diclofenac sodium in terms of a very low detection limit, high sensitivity, very good accuracy, repeatability and reproducibility. - Highlights: • GCE was modified with multiwalled carbon nanotube and gold nanoparticles. • AuNP/MWCNT/GCE was used for the determination of diclofenac sodium. • Modified electrode was characterized by SEM, EDS and EIS. • The proposed method showed excellent analytical figures of merit. • This sensor was used for the determination of diclofenac sodium in real samples.

  5. Excessive pressure in multichambered cuffs used for sequential compression therapy

    NARCIS (Netherlands)

    Segers, P; Belgrado, JP; Leduc, A; Leduc, O; Verdonck, P

    2002-01-01

    Background and Purpose. Pneumatic compression devices, used as part of the therapeutic strategy for lymphatic drainage, often have cuffs with multiple chambers that are, inflated sequentially. The purpose of this study was to investigate (1) the relationship between cuff chamber pressure

  6. Electrical Contacts in Monolayer Arsenene Devices.

    Science.gov (United States)

    Wang, Yangyang; Ye, Meng; Weng, Mouyi; Li, Jingzhen; Zhang, Xiuying; Zhang, Han; Guo, Ying; Pan, Yuanyuan; Xiao, Lin; Liu, Junku; Pan, Feng; Lu, Jing

    2017-08-30

    Arsenene, arsenic analogue of graphene, as an emerging member of two-dimensional semiconductors (2DSCs), is quite promising in next-generation electronic and optoelectronic applications. The metal electrical contacts play a vital role in the charge transport and photoresponse processes of nanoscale 2DSC devices and even can mask the intrinsic properties of 2DSCs. Here, we present a first comprehensive study of the electrical contact properties of monolayer (ML) arsenene with different electrodes by using ab initio electronic calculations and quantum transport simulations. Schottky barrier is always formed with bulk metal contacts owing to the Fermi level pinning (pinning factor S = 0.33), with electron Schottky barrier height (SBH) of 0.12, 0.21, 0.25, 0.35, and 0.50 eV for Sc, Ti, Ag, Cu, and Au contacts and hole SBH of 0.75 and 0.78 eV for Pd and Pt contacts, respectively. However, by contact with 2D graphene, the Fermi level pinning effect can be reduced due to the suppression of metal-induced gap states. Remarkably, a barrier free hole injection is realized in ML arsenene device with graphene-Pt hybrid electrode, suggestive of a high device performance in such a ML arsenene device. Our study provides a theoretical foundation for the selection of favorable electrodes in future ML arsenene devices.

  7. Dynamic solar-powered multi-stage direct contact membrane distillation system: Concept design, modeling and simulation

    KAUST Repository

    Lee, Jung Gil; Kim, Woo-Seung; Choi, June-Seok; Ghaffour, NorEddine; Kim, Young-Deuk

    2017-01-01

    This paper presents a theoretical analysis of the monthly average daily and hourly performances of a solar-powered multi-stage direct contact membrane distillation (SMDCMD) system with an energy recovery scheme and dynamic operating system. Mid

  8. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    Science.gov (United States)

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  9. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    Science.gov (United States)

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  10. Glucose aided preparation of tungsten sulfide/multi-wall carbon nanotube hybrid and use as counter electrode in dye-sensitized solar cells.

    Science.gov (United States)

    Wu, Jihuai; Yue, Gentian; Xiao, Yaoming; Huang, Miaoliang; Lin, Jianming; Fan, Leqing; Lan, Zhang; Lin, Jeng-Yu

    2012-12-01

    The tungsten sulfide/multi-wall carbon nanotube (WS(2)/MWCNT) hybrid was prepared in the presence of glucose by the hydrothermal route. The hybrid materials were used as counter electrode in the dye-sensitized solar cell (DSSC). The results of cyclic voltammetry measurement and electrochemical impedance spectroscopy indicated that the glucose aided prepared (G-A) WS(2)/MWCNT electrode had low charge-transfer resistance (R(ct)) and high electrocatalytic activity for triiodide reduction. The excellent electrochemical properties for (G-A) WS(2)/MWCNT electrode is due to the synergistic effects of WS(2) and MWCNTs, as well as amorphous carbon introduced by glucose. The DSSC based on the G-A WS(2)/MWCNT counter electrode achieved a high power conversion efficiency of 7.36%, which is comparable with the performance of the DSSC using Pt counter electrode (7.54%).

  11. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Chenona (Korea, Republic of)

    1992-11-15

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain.

  12. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl; Yu, Pil Mun

    1992-01-01

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain

  13. Fundamental study on a thin-film ae sensor for measurement of behavior of a multi-pad contact slider

    NARCIS (Netherlands)

    Imai, S.; Burger, G.J.; Lammerink, Theodorus S.J.; Fluitman, J.H.J.

    To study the fundamental dynamic characteristics of a multi-pad slider for contact recording, we developed a thin-film piezoelectric acoustic emission array sensor on an Si-suspension with an array pattern similar to that of contact pads. Experiments showed that the sensitivity of the sensor is

  14. Preoperative and post-operative sleep quality evaluation in rotator cuff tear patients.

    Science.gov (United States)

    Serbest, Sancar; Tiftikçi, Uğur; Askın, Aydogan; Yaman, Ferda; Alpua, Murat

    2017-07-01

    The aim of this study was to examine the potential relationship between subjective sleep quality and degree of pain in patients with rotator cuff repair. Thirty-one patients who underwent rotator cuff repair prospectively completed the Pittsburgh Sleep Quality Index, the Western Ontario Rotator Cuff Index, and the Constant and Murley shoulder scores before surgery and at 6 months after surgery. Preoperative demographic, clinical, and radiologic parameters were also evaluated. The study analysed 31 patients with a median age of 61 years. There was a significant difference preoperatively versus post-operatively in terms of all PSQI global scores and subdivisions (p Rotator Cuff Scale and the Constant and Murley shoulder scores (p ˂ 0.001). Sleep disorders are commonly seen in patients with rotator cuff tear, and after repair, there is an increase in the quality of sleep with a parallel improvement in shoulder functions. However, no statistically significant correlation was determined between arthroscopic procedures and the size of the tear and sleep quality. It is suggested that rotator cuff tear repair improves the quality of sleep and the quality of life. IV.

  15. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    Science.gov (United States)

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  16. Evaluation of the Risk Factors for a Rotator Cuff Retear After Repair Surgery.

    Science.gov (United States)

    Lee, Yeong Seok; Jeong, Jeung Yeol; Park, Chan-Deok; Kang, Seung Gyoon; Yoo, Jae Chul

    2017-07-01

    A retear is a significant clinical problem after rotator cuff repair. However, no study has evaluated the retear rate with regard to the extent of footprint coverage. To evaluate the preoperative and intraoperative factors for a retear after rotator cuff repair, and to confirm the relationship with the extent of footprint coverage. Cohort study; Level of evidence, 3. Data were retrospectively collected from 693 patients who underwent arthroscopic rotator cuff repair between January 2006 and December 2014. All repairs were classified into 4 types of completeness of repair according to the amount of footprint coverage at the end of surgery. All patients underwent magnetic resonance imaging (MRI) after a mean postoperative duration of 5.4 months. Preoperative demographic data, functional scores, range of motion, and global fatty degeneration on preoperative MRI and intraoperative variables including the tear size, completeness of rotator cuff repair, concomitant subscapularis repair, number of suture anchors used, repair technique (single-row or transosseous-equivalent double-row repair), and surgical duration were evaluated. Furthermore, the factors associated with failure using the single-row technique and transosseous-equivalent double-row technique were analyzed separately. The retear rate was 7.22%. Univariate analysis revealed that rotator cuff retears were affected by age; the presence of inflammatory arthritis; the completeness of rotator cuff repair; the initial tear size; the number of suture anchors; mean operative time; functional visual analog scale scores; Simple Shoulder Test findings; American Shoulder and Elbow Surgeons scores; and fatty degeneration of the supraspinatus, infraspinatus, and subscapularis. Multivariate logistic regression analysis revealed patient age, initial tear size, and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the single-row group

  17. Factors affecting rotator cuff healing after arthroscopic repair: osteoporosis as one of the independent risk factors.

    Science.gov (United States)

    Chung, Seok Won; Oh, Joo Han; Gong, Hyun Sik; Kim, Joon Yub; Kim, Sae Hoon

    2011-10-01

    The prognostic factors associated with structural outcome after arthroscopic rotator cuff repair have not yet been fully determined. The hypothesis of this study was that bone mineral density (BMD) is an important prognostic factor affecting rotator cuff healing after arthroscopic cuff repair. Cohort study; Level of evidence, 3. Among 408 patients who underwent arthroscopic repair for full-thickness rotator cuff tear between January 2004 and July 2008, 272 patients were included whose postoperative cuff integrity was verified by computed tomography arthrography (CTA) or ultrasonography (USG) and simultaneously who were evaluated by various functional outcome instruments. The mean age at the time of operation was 59.5 ± 7.9 years. Postoperative CTA or USG was performed at a mean 13.0 ± 5.1 months after surgery, and the mean follow-up period was 37.2 ± 10.0 months (range, 24-65 months). The clinical, structural, and surgery-related factors affecting cuff integrity including BMD were analyzed using both univariate and multivariate analysis. Evaluation of postoperative cuff integrity was performed by musculoskeletal radiologists who were unaware of the present study. The failure rate of rotator cuff healing was 22.8% (62 of 272). The failure rate was significantly higher in patients with lower BMD (P cuff healing failure following arthroscopic rotator cuff repair. Bone mineral density, as well as FI of the infraspinatus and amount of retraction, was an independent determining factor affecting postoperative rotator cuff healing. Further studies with prospective, randomized, and controlled design are needed to confirm the relationship between BMD and postoperative rotator cuff healing.

  18. A solid-contact Pb{sup 2+}-selective electrode using poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene) as ion-to-electron transducer

    Energy Technology Data Exchange (ETDEWEB)

    Yu Shunyang [CAS and Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003 (China); Li Fuhai [CAS and Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003 (China); Chemistry and Chemical Engineering College, Yantai University, Yantai 264005 (China); Yin Tanji [CAS and Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003 (China); Liu Yongming [Chemistry and Chemical Engineering College, Yantai University, Yantai 264005 (China); Pan, Dawei [CAS and Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003 (China); Qin Wei, E-mail: wqin@yic.ac.cn [CAS and Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003 (China)

    2011-09-30

    Highlights: {yields} All reagents used for the electrodes preparation were commercially available. {yields} The lower detection limit of the proposed electrode reached subnanomolar levels. {yields} No water film was observed with conventional commercially available PVC ion-sensing membranes. {yields} This research provides an excellent strategy for fabrication of robust polymeric ion sensors. - Abstract: In this work, a novel all-solid-state polymeric membrane Pb{sup 2+}-selective electrode was developed by using for the first time poly(2-methoxy-5-(2'-ethylhexyloxy)-p-phenylene vinylene) (MEH-PPV) as solid contact. To demonstrate the ion-to-electron transducing ability of MEH-PPV, chronopotentiometry and electrochemical impedance spectroscopy measurements were carried out. The proposed electrodes showed a Nernstian response of 29.1 mV decade{sup -1} and a lower detection limit of subnanomolar level. No water film was observed with the conventional plasticized PVC membrane. This work demonstrates a new strategy for the fabrication of robust potentiometric ion sensors.

  19. A surface-micromachining-based inertial micro-switch with compliant cantilever beam as movable electrode for enduring high shock and prolonging contact time

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Qiu [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Yang, Zhuoqing, E-mail: yzhuoqing@sjtu.edu.cn [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Fu, Bo; Li, Jianhua; Wu, Hao [Huaihai Industrial Group Co., Ltd., Changzhi, Shanxi Province, 046012 (China); Zhang, Qihuan; Sun, Yunna; Ding, Guifu; Zhao, Xiaolin [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China)

    2016-11-30

    Highlights: • The designed cantilever beam attached to the proof mass can endure a larger shock acceleration (∼1000 g order of magnitude) compared to those traditional designs (∼100 g order of magnitude). • Effect of the pulse width on the threshold acceleration, the response time and the contact time is investigated. • A constraint sleeve structure is introduced to lower the off-axis sensitivity. - Abstract: A novel laterally-driven inertial micro-switch with two L-shaped elastic cantilever beams as the movable electrode, which is attached to the proof mass, is proposed in this paper. The advantage of this design is that the contact time of the inertial micro-switch can be prolonged. Meanwhile, the micro-switch can withstand a higher shock than the traditional designs whose cantilever beams are attached to the fixed electrode. The designed inertial micro-switch was simulated and optimized with ANSYS software and fabricated on a quartz substrate by surface micromachining technology. The simulated result demonstrates that the threshold acceleration (a{sub ths}) under stable switch-on state is about 288 g and the contact time is about 198 μs when the pulse width of acceleration loads is 1 ms. At the same time, it indicates that the threshold acceleration, the response time and the contact time of designed micro-switch all increase with the pulse width of acceleration loads. The simulation of impact process in non-sensitive direction shows that the introduced constraint sleeve structure in the novel inertial micro-switch can lower the off-axis sensitivity. The fabricated micro-switch prototype has been tested by a standard dropping hammer system under shock accelerations with various amplitudes and pulse widths. The experimental measurements show that the contact time is about 150 μs when the threshold acceleration is about 288 g. It also indicates that the response time and the contact time both increase with the pulse width, which is consistent with the

  20. Case Report of Acute Traumatic Rotator Cuff Tear Treatment in Traditional Korean Medicine

    Directory of Open Access Journals (Sweden)

    Jeong-Hwan Lee

    2011-12-01

    Full Text Available Objectives: There is no report on treatment of acute traumatic rotator cuff tear in Traditional Korean Medicine. We reported Traditional Korean Treatment for pain relief and better movement of acute traumatic rotator cuff tear. Methods: Shoulder MRI was used to confirm the diagnosis of tear of rotator cuff. The patient was treated with Traditional Korean Methods (Acupuncture, Herbal medicine, Pharmacopuncture for 6 months. We evaluated the patient through VAS (Visual Analogue Scale, UCLA shoulder scale, ROM (Range of motion and Shoulder MRI. Results: After 6 months of treatment, the patient's VAS was decreased whereas UCLA score and Shoulder ROM were increased. Rotator cuff tear was repaired on Shoulder MRI images. Conclusions: In acute traumatic rotator cuff tear, Korean Traditional Treatment is good method for pain relief and better movement.

  1. The analysis of spatial relationship between the rotator cuff and the subacromial space in different arm positions

    International Nuclear Information System (INIS)

    Zou Yuefen; Wang Dehang; Wang Xiaoning; Li Shener

    2003-01-01

    Objective: To explore the distance between the acromion and the humerus head at different arm abduction to observe whether it changes or not, to determine at which position the distance is smallest, and to evaluate the relationship between the subacromial space and the rotator cuff. Methods: Fifteen normal volunteers were examined with MRI in six arm positions, and the coronal thin images were obtained with a spin echo sequence. Using a special positioning device, the arm was placed at 0 degree, 30 degree, 60 degree, 90 degree, 120 degree and 150 degree arm abduction, respectively. Of them, 0 degree-90 degree positions were not rotated, while 120 degree and 150 degree positions were slight internal rotated. The minimal distance of acromion-humerus (A-H) and clavicle-humerus (C-H), and the spatial relationship between the rotator cuff and the subacromial space were measured and observed. Results: The values of A-H and C-H at 60 degree - 150 degree arm abduction were obviously smaller than those at 0 degree-30 degree arm abduction (P 0.05). The rotator cuff (mainly supraspinatus tendon) just went through between the acromion and the humerus at 60 degree - 120 degree arm positions but not at 0 degree, 30 degree and 150 degree arm positions. So at 60 degree - 120 degree arm positions, rotator cuff between the humerus and the acromion was often impinged. Conclusion: The closest contact between the supraspinatus tendon and subacromial space occurs at 60 degree - 120 degree abduction. The findings testify that the patients with impingement syndrome have shoulder pain at 60 degree - 120 degree abduction in clinic from etiology and pathology. In the future, MRI-based analyses should allow investigating the morphological basis of the impingement syndrome, choosing the appropriate therapy, and minimizing failure rates of surgery

  2. Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.

    Science.gov (United States)

    Mariyaselvam, Maryanne Z; Marsh, Lucy L; Bamford, Sarah; Smith, Ann; Wise, Matt P; Williams, David W

    2017-03-04

    Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p aspiration across the range of diameters compared to the SealGuard (p aspiration, relating to cuff material and design. Variability in performance was likely due to the random manner in which involutional folds form in the inflated ETT cuff. The PneuX ETT was the only ETT able to consistently prevent aspiration past the cuff in all experiments.

  3. Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?

    Science.gov (United States)

    Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J; Miller, Bruce

    2018-03-01

    Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Cohort study; Level of evidence, 3. Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC ( P = .96), ASES ( P = .71), or VAS ( P = .86). Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair.

  4. Early postoperative fluoroquinolone use is associated with an increased revision rate after arthroscopic rotator cuff repair.

    Science.gov (United States)

    Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Young, Chris; Werner, Brian C

    2017-07-01

    To evaluate the association of postoperative fluoroquinolone use following arthroscopic primary rotator cuff repair with failure requiring revision rotator cuff repair. An insurance database was queried for patients undergoing rotator cuff repair from 2007 to 2015. These patients were divided into three groups: (1) patients prescribed fluoroquinolones within 6 months postoperatively (divided into 0-2, 2-4, and 4-6 months), (2) a matched negative control cohort of patients not prescribed fluoroquinolones, and (3) a matched positive control cohort of patients prescribed fluoroquinolones between 6 and 18 months following rotator cuff repair. Rates of failure requiring revision rotator cuff repair were compared within 2 years. A total of 1292 patients were prescribed fluoroquinolones within 6 months after rotator cuff repair, including 442 within 2 months, 433 within 2 to 4 months, and 417 within 4 to 6 months, and were compared to 5225 matched negative controls and 1597 matched positive controls. The rate of revision rotator cuff repair was significantly higher in patients prescribed fluoroquinolones within 2 months (6.1 %) compared to matched negative (2.2 %, P = 0.0009) and positive controls (2.4 %, P = 0.0026). There were no significant differences in the rate of revision rotator cuff repair when fluoroquinolones were prescribed >2 months after rotator cuff repair. Early use of fluoroquinolones following rotator cuff repair was independently associated with significantly increased rates of failure requiring revision rotator cuff repair. This is the first clinical study examining the association of postoperative fluoroquinolone use with failure following arthroscopic rotator cuff repair. III.

  5. Electrochemical Oxidation of Sulfamethazine on Multi-Walled Nanotube Film Coated Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    L. Fotouhi

    2014-04-01

    Full Text Available The electrochemical oxidation of sulfamethazine (SMZ has been studied at a multi-walled carbon nanotubes modified glassy carbon electrode (MWCNT-GCE by cyclic voltammetry. This modified electrode (MWCNT-GCE exhibited excellent electrocatalytic behavior toward the oxidation of SMZ as evidenced by the enhancement of the oxidation peak current and the shift in the anodic potential to less positive values (170 mV in comparison with the bare GCE. The formal potential, E0', of SMZ is pH dependent with a slope of 54 mV per unit of pH, close to the anticipated Nerstian value of 59 mV for a 2-electron and 2-proton oxidation process. A detailed analysis of cyclic voltammograms gave fundamental electrochemical parameters including the electroactive surface coverage (Г, the transfer coefficient (a, the heterogeneous rate constant (ks. Under the selected conditions, the peak current shows two dynamic linear ranges of 10-200 mM and 300-3000 mM with the detection limit of 6.1 mM. The method was successfully applied to analyze SMZ in serum sample

  6. Surgery or conservative treatment for rotator cuff tear: a meta-analysis.

    Science.gov (United States)

    Ryösä, Anssi; Laimi, Katri; Äärimaa, Ville; Lehtimäki, Kaisa; Kukkonen, Juha; Saltychev, Mikhail

    2017-07-01

    Comparative evidence on treating rotator cuff tear is inconclusive. The objective of this review was to evaluate the evidence on effectiveness of tendon repair in reducing pain and improving function of the shoulder when compared with conservative treatment of symptomatic rotator cuff tear. Search on CENTRAL, MEDLINE, EMBASE, CINAHL, Web of Science and Pedro databases. Randomised controlled trials (RCT) comparing surgery and conservative treatment of rotator cuff tear. Study selection and extraction based on the Cochrane Handbook for Systematic reviews of Interventions. Random effects meta-analysis. Three identified RCTs involved 252 participants (123 cases and 129 controls). The risk of bias was considered low for all three RCTs. For Constant score, statistically insignificant effect size was 5.6 (95% CI -0.41 to 11.62) points in 1-year follow up favouring surgery and below the level of minimal clinically important difference. The respective difference in pain reduction was -0.93 (95% CI -1.65 to -0.21) cm on a 0-10 pain visual analogue scale favouring surgery. The difference was statistically significant (p = 0.012) in 1-year follow up but below the level of minimal clinically important difference. There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. Thus, a conservative approach is advocated as the initial treatment modality. Implications for Rehabilitation There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. There was no clinically significant difference between surgery and active physiotherapy in 1-year follow-up in improving Constant score or reducing pain caused by rotator cuff tear. As physiotherapy is less proneness to complications and less expensive than surgery, a conservative approach is advocated as the initial treatment modality to rotator cuff tears.

  7. Rotator cuff repair healing influenced by platelet-rich plasma construct augmentation.

    Science.gov (United States)

    Barber, F Alan; Hrnack, Scott A; Snyder, Stephen J; Hapa, Onur

    2011-08-01

    To assess the effect of platelet-rich plasma fibrin matrix (PRPFM) construct augmentation on postoperative tendon healing as determined by magnetic resonance imaging (MRI) and clinical outcome of arthroscopic rotator cuff repair. A comparative series of patients undergoing arthroscopic rotator cuff repair was studied. Two matched groups of patients (20 each) were included: rotator cuff repairs without PRPFM augmentation (group 1) and rotator cuff repairs augmented with 2 sutured platelet-rich plasma (PRP) constructs (group 2). A single-row cuff repair to the normal footprint without tension or marrow vents was performed by a single surgeon. Postoperative rehabilitation was held constant. Postoperative MRI scans were used to evaluate rotator cuff healing. Outcome measures included American Shoulder and Elbow Surgeons, Rowe, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Constant scores. We followed up 40 patients (2 matched groups with 20 patients each) with a mean age of 57 years (range, 44 to 69 years) for a mean of 31 months (range, 24 to 44 months). Postoperative MRI studies showed persistent full-thickness tendon defects in 60% of controls (12 of 20) and 30% of PRPFM-augmented repairs (6 of 20) (P = .03). Of the control group tears measuring less than 3 cm in anteroposterior length, 50% (7 of 14) healed fully, whereas 86% of the PRPFM group tears measuring less than 3 cm in anteroposterior length (12 of 14) healed fully (P rotator cuff tendon repair resulted in lower retear rates identified on MRI than repairs without the constructs. Other than the Rowe scores, there was no postoperative clinical difference by use of standard outcome measures. Level III, case-control study. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

    Science.gov (United States)

    Baums, M H; Kostuj, T; Klinger, H-M; Papalia, R

    2016-02-01

    The goal of rotator cuff repair is a high initial mechanical stability as a requirement for adequate biological recovery of the tendon-to-bone complex. Notwithstanding the significant increase in publications concerning the topic of rotator cuff repair, there are still controversies regarding surgical technique. The aim of this work is to present an overview of the recently published results of biomechanical and clinical studies on rotator cuff repair using single- and double-row techniques. The review is based on a selective literature research of PubMed, Embase, and the Cochrane Database on the subject of the clinical and biomechanical results of single- and double-row repair. In general, neither the biomechanical nor the clinical evidence can recommend the use of a double-row concept for the treatment for every rotator cuff tear. Only tears of more than 3 cm seem to benefit from better results on both imaging and in clinical outcome studies compared with the use of single-row techniques. Despite a significant increase in publications on the surgical treatment of rotator cuff tears in recent years, the clinical results were not significantly improved in the literature so far. Unique information and algorithms, from which the optimal treatment of this entity can be derived, are still inadequate. Because of the cost-effectiveness and the currently vague evidence, the double-row techniques cannot be generally recommended for the repair of all rotator cuff tears.

  9. Effect of Preoperative Fatty Degeneration of the Rotator Cuff Muscles on the Clinical Outcome of Patients With Intact Tendons After Arthroscopic Rotator Cuff Repair of Large/Massive Cuff Tears.

    Science.gov (United States)

    Ohzono, Hiroki; Gotoh, Masafumi; Nakamura, Hidehiro; Honda, Hirokazu; Mitsui, Yasuhiro; Kakuma, Tatsuyuki; Okawa, Takahiro; Shiba, Naoto

    2017-11-01

    Fatty degeneration of the rotator cuff muscles is associated not only with postoperative retear but also with postoperative muscle weakness; therefore, fatty changes in the muscles may affect the clinical outcome even in patients with these tears who have intact tendons after arthroscopic rotator cuff repair (ARCR). To evaluate the effect of fatty infiltration on the clinical outcome in patients with intact tendons after arthroscopic repair of large/massive cuff tears. Case-control study; Level of evidence, 3. One hundred fifty-five consecutive patients with large/massive rotator cuff tears underwent ARCR. Of these, 55 patients (mean ± SD age, 64.4 ± 9.1 years) in whom intact tendons after surgery were confirmed with magnetic resonance imaging at final follow-up (mean ± SD, 2.5 ± 1.4 years) were included in this study. Depending on their University of California Los Angeles (UCLA) score at the final follow-up, they were assigned to either the unsatisfactory group (score ≤27; n = 12) or the satisfactory group (score >27; n = 43). Various clinical parameters affecting the clinical outcome were examined through univariate and multivariate analyses. The UCLA score of all patients significantly improved from 18.1 ± 4.4 points preoperatively to 29.8 ± 4.5 points postoperatively ( P muscles, with area under the curve values of 0.79 (sensitivity 91% and specificity 51%) and 0.84 (sensitivity 100% and specificity 54%) in the infraspinatus and subscapularis, respectively. Preoperative fatty degeneration of the infraspinatus and/or subscapularis with Goutallier stage 2 or higher was significantly associated with worse outcome in patients with large/massive tears who had intact tendons after ARCR.

  10. MR arthrography gadolinium versus standard MR imaging in rotator cuff pathology

    International Nuclear Information System (INIS)

    Hodler, J.; Brahme, S.K.; Karzel, R.; Cervilla, V.; Snyder, S.; Schweitzer, M.; Flannigan, B.; Resnick, D.

    1990-01-01

    This paper compares the accuracy of MR imaging with and without intraarticular gadolinium in the diagnosis of rotator cuff pathology, using arthroscopy as the gold standard. The authors examined 36 patients, first with T2-weighted sequences and then with T1-weighted sequences after the injection of 15-20 mL of diluted gadolinium. The images were read blindly by three radiologists experienced in musculoskeletal MR imaging. The results were compared with those of arthroscopy. In 16 of 19 arthroscopically intact rotator cuffs, both sequences demonstrated no evidence of rotator cuff tear. The remaining three cases were interpreted as partial or full-thickness tears. Of 12 partial tears, T1-weighted images with intraarticular gadolinium demonstrated a partial tear in five, degeneration in four, a full thickness tear in two, and a normal rotator cuff in one

  11. Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components

    NARCIS (Netherlands)

    D.R. Suárez (Daniel); E.R. Valstar (Edward); J.C. Linden (Jacqueline); F. van Keulen (Fred); P.M. Rozing (Piet)

    2009-01-01

    textabstractThe functional outcome of shoulder replacement is related to the condition of the rotator cuff. Rotator cuff disease is a common problem in candidates for total shoulder arthroplasty; this study relates the functional status of the rotator cuff to the initial stability of a cementless

  12. Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need

    DEFF Research Database (Denmark)

    Rokamp, K.Z.; Secher, N.H.; Møller, Ann

    2010-01-01

    ABSTRACT: BACKGROUND: To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD: In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without...... the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and laryngeal masks. RESULTS: In the 119 patients provided with a tracheal tube, the median cuff pressure was 30 (range 8 - 100) cm H2O and the pressure exceeded 30 cm H2O (upper recommended level) for 54...... patients. In the 82 patients provided with a laryngeal mask, the cuff pressure was 95 (10 - 121) cm H2O and above 60 cm H2O (upper recommended level) for 56 patients and in 34 of these patients, the pressure exceeded the upper cuff gauge limit (120 cm H2O). There was no association between cuff pressure...

  13. Clinical results of arthroscopic polyglycolic acid sheet patch graft for irreparable rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Yu Mochizuki

    2015-01-01

    Full Text Available The high retear rates after surgery for irreparable rotator cuff tears can be explained by the healing capacity potential of tendons and the native rotator cuff enthesis characterised by complex morphological structures, called direct insertion. Many experimental researches have focused on biologically augmenting the rotator cuff reconstruction and improving tendon–bone healing of the rotator cuff. The results of the experimental study showed that the polyglycolic acid sheet scaffold material allows for the regeneration of not only tendon-to-tendon, but also tendon-to-bone interface in an animal model. We performed a clinical study of the arthroscopic polyglycolic acid sheet patch graft used for the repair of irreparable rotator cuff tears. One-year clinical results of the repair of irreparable rotator cuff tears by arthroscopic patch graft with a polyglycolic acid sheet demonstrated improved shoulder function and a significantly lower retear rate, compared with patients treated with a fascia lata patch.

  14. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    International Nuclear Information System (INIS)

    Zbojniewicz, Andrew M.; Emery, Kathleen H.; Maeder, Matthew E.; Salisbury, Shelia R.

    2014-01-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  15. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    Energy Technology Data Exchange (ETDEWEB)

    Zbojniewicz, Andrew M.; Emery, Kathleen H. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Maeder, Matthew E. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Lenox Hill Hospital, Department of Radiology, New York, NY (United States); Salisbury, Shelia R. [University of Cincinnati College of Medicine, Division of Biostatistics and Epidemiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2014-06-15

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  16. Direct electrochemistry with enhanced electrocatalytic activity of hemoglobin in hybrid modified electrodes composed of graphene and multi-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei, E-mail: swyy26@hotmail.com [College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158 China (China); College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Cao, Lili; Deng, Ying; Gong, Shixing [College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Shi, Fan; Li, Gaonan; Sun, Zhenfan [College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158 China (China)

    2013-06-05

    Graphical abstract: -- Highlights: •A graphene and multi-walled carbon nanotubes nanocomposite was prepared. •Hemoglobin and nanocomposite modified carbon ionic liquid electrode was fabricated. •Direct electrochemistry of hemoglobin was realized on the modified electrode. •Bioelectrocatalysis towards the reduction of different substrates was enhanced. -- Abstract: A graphene (GR) and multi-walled carbon nanotubes (MWCNT) hybrid was prepared and modified on a 1-hexylpyridinium hexafluorophosphate based carbon ionic liquid electrode (CILE). Hemoglobin (Hb) was immobilized on GR-MWCNT/CILE surface with Nafion as the film forming material and the modified electrode was denoted as Nafion/Hb-GR-MWCNT/CILE. Spectroscopic results revealed that Hb molecules retained its native structure in the GR-MWCNT hybird. Electrochemical behaviors of Hb were carefully investigated by cyclic voltammetry with a pair of well-defined redox peaks obtained, which indicated that direct electron transfer of Hb was realized in the hybrid modified electrode. The result could be attributed to the synergistic effects of GR-MWCNT hybrid with enlarged surface area and improved conductivity through the formation of a three-dimensional network. Electrochemical parameters of the immobilized Hb on the electrode surface were further calculated with the results of the electron transfer number (n) as 1.03, the charge transfer coefficient (a) as 0.58 and the electron-transfer rate constant (k{sub s}) as 0.97 s{sup −1}. The Hb modified electrode showed good electrocatalytic ability toward the reduction of different substrates such as trichloroacetic acid in the concentration range from 0.05 to 38.0 mmol L{sup −1} with a detection limit of 0.0153 mmol L{sup −1} (3σ), H{sub 2}O{sub 2} in the concentration range from 0.1 to 516.0 mmol L{sup −1} with a detection limit of 34.9 nmol/L (3σ) and NaNO{sub 2} in the concentration range from 0.5 to 650.0 mmol L{sup −1} with a detection limit of 0

  17. Direct electrochemistry with enhanced electrocatalytic activity of hemoglobin in hybrid modified electrodes composed of graphene and multi-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Sun, Wei; Cao, Lili; Deng, Ying; Gong, Shixing; Shi, Fan; Li, Gaonan; Sun, Zhenfan

    2013-01-01

    Graphical abstract: -- Highlights: •A graphene and multi-walled carbon nanotubes nanocomposite was prepared. •Hemoglobin and nanocomposite modified carbon ionic liquid electrode was fabricated. •Direct electrochemistry of hemoglobin was realized on the modified electrode. •Bioelectrocatalysis towards the reduction of different substrates was enhanced. -- Abstract: A graphene (GR) and multi-walled carbon nanotubes (MWCNT) hybrid was prepared and modified on a 1-hexylpyridinium hexafluorophosphate based carbon ionic liquid electrode (CILE). Hemoglobin (Hb) was immobilized on GR-MWCNT/CILE surface with Nafion as the film forming material and the modified electrode was denoted as Nafion/Hb-GR-MWCNT/CILE. Spectroscopic results revealed that Hb molecules retained its native structure in the GR-MWCNT hybird. Electrochemical behaviors of Hb were carefully investigated by cyclic voltammetry with a pair of well-defined redox peaks obtained, which indicated that direct electron transfer of Hb was realized in the hybrid modified electrode. The result could be attributed to the synergistic effects of GR-MWCNT hybrid with enlarged surface area and improved conductivity through the formation of a three-dimensional network. Electrochemical parameters of the immobilized Hb on the electrode surface were further calculated with the results of the electron transfer number (n) as 1.03, the charge transfer coefficient (a) as 0.58 and the electron-transfer rate constant (k s ) as 0.97 s −1 . The Hb modified electrode showed good electrocatalytic ability toward the reduction of different substrates such as trichloroacetic acid in the concentration range from 0.05 to 38.0 mmol L −1 with a detection limit of 0.0153 mmol L −1 (3σ), H 2 O 2 in the concentration range from 0.1 to 516.0 mmol L −1 with a detection limit of 34.9 nmol/L (3σ) and NaNO 2 in the concentration range from 0.5 to 650.0 mmol L −1 with a detection limit of 0.282 μmol L −1 (3σ). So the proposed

  18. Studies of the source complex behaviour and of the ultrasound radiation of contact flexible multi-element transducers; Etudes du comportement complexe de source et du rayonnement ultrasonore des traducteurs multi-elements flexibles au contact

    Energy Technology Data Exchange (ETDEWEB)

    Amory, V

    2007-12-15

    This work deals with the ultrasonic nondestructive testing of parts with complex geometries using soft multi-element sensors. The different types of contact control configurations are presented first. Then, the difficulties encountered with conventional contact transducers are explained and the multi-element piezoelectric transducers technology, developed to meet these difficulties, is presented. The second chapter presents the results of finite-element calculations showing the complexity of a transducer in a condition of testing utilization. In a same configuration, the radiated far field calculated by finite-elements is compared to the measurement in order to validate the way the source behaviour is calculated. However, despite the efficiency of the finite-elements simulation, this tool is numerically too costly and cannot be used to optimize a full multi-element transducer. Therefore, a realistic source model is built and implemented in a radiation code based on high-frequency asymptotic approximations where only L and T volume waves are calculated. The incapacity of this model to reproduce the behaviour of T waves in some directions of propagation has led to give a particular attention to the fore-waves, neglected in the radiation calculation. Chapter 3 treats of the building of an exact radiation model taking into consideration the fore-waves contribution emitted by a contact transducer exerting a random space-time distribution constraint at the surface of the considered medium. A radiation model, based on the calculation of exact Green functions of the Lamb problem is proposed. The exact model is particularly interesting in the case of sensor geometries with a long length with respect to other dimensions (2D case). Field calculation results are shown for an element of the matrix network (3D case) and for a linear element (2D case). A study of different existing approached models is carried out as well. The last chapter presents some results of the field

  19. MR Imaging of Rotator Cuff Tears: Correlation with Arthroscopy

    Science.gov (United States)

    Bhandary, Sudarshan; Khandige, Ganesh; Kabra, Utkarsh

    2017-01-01

    Introduction Rotator cuff tears are quite common and can cause significant disability. Magnetic Resonance Imaging (MRI) has now emerged as the modality of choice in the preoperative evaluation of patients with rotator cuff injuries, in view of its improved inherent soft tissue contrast and resolution. Aim To evaluate the diagnostic accuracy of routine MRI in the detection and characterisation of rotator cuff tears, by correlating the findings with arthroscopy. Materials and Methods This prospective study was carried out between July 2014 and August 2016 at the AJ Institute of Medical Sciences, Mangalore, Karnataka, India. A total of 82 patients were diagnosed with rotator cuff injury on MRI during this period, out of which 45 patients who underwent further evaluation with arthroscopy were included in this study. The data collected was analysed for significant correlation between MRI diagnosis and arthroscopic findings using kappa statistics. The sensitivity, specificity, predictive value and accuracy of MRI for the diagnosis of full and partial thickness tears were calculated using arthroscopic findings as the reference standard. Results There were 27 males and 18 females in this study. The youngest patient was 22 years and the oldest was 74 years. Majority of rotator cuff tears (78%) were seen in patients above the age of 40 years. MRI showed a sensitivity of 89.6%, specificity of 100%, positive predictive value of 100% and negative predictive value of 83.3% for the diagnosis of full thickness rotator cuff tears. For partial thickness tears, MRI showed a sensitivity of 100%, specificity of 86.6%, positive predictive value of 78.9% and negative predictive value of 100%. The accuracy was 93.1% for full thickness tears and 91.1% for partial thickness tears. The p-value was less than 0.01 for both full and partial thickness tears. There was good agreement between the MRI and arthroscopic findings, with kappa value of 0.85 for full thickness tears and 0.81 for partial

  20. Rotator Cuff Strength Ratio and Injury in Glovebox Workers

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Amelia M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-01-30

    Rotator cuff integrity is critical to shoulder health. Due to the high workload imposed upon the shoulder while working in an industrial glovebox, this study investigated the strength ratio of the rotator cuff muscles in glovebox workers and compared this ratio to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forces produced in the motions of shoulder internal and external rotation. Results showed this population to have shoulder strength ratios that were significantly different from the healthy norm. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature of glovebox workers in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development.

  1. Enhancement of the efficiency of dye-sensitized solar cell with multi-wall carbon nanotubes/polythiophene composite counter electrodes prepared by electrodeposition

    Science.gov (United States)

    Luo, Jun; Niu, Hai-jun; Wu, Wen-jun; Wang, Cheng; Bai, Xu-duo; Wang, Wen

    2012-01-01

    For the purpose of increasing the energy conversion efficiency of dye-sensitized solar cells (DSSCs), multi-wall carbon nanotube (MWCNT)/polythiophene (PTh) composite film counter electrode has been fabricated by electrophoresis and cyclic voltammetry (CV) in sequence. The morphology and chemical structure have been characterized by transmission electron microscopy (TEM), scanning electron microscope (SEM), and Raman spectroscopy respectively. The overall energy conversion efficiency of the DSSC employing the MWCNT/PTh composite film has reached 4.72%, which is close to that of the DSSC with a platinum (Pt) counter electrode (5.68%). Compared with a standard DSSC with MWCNT counter electrode whose efficiency is 2.68%, the energy conversion efficiency has been increased by 76.12% for the DSSC with MWCNT/PTh counter electrode. These results indicate that the composite film with high conductivity, high active surface area, and good catalytic properties for I 3- reduction can potentially be used as the counter electrode in a high-performance DSSC.

  2. Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.

    Science.gov (United States)

    Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D

    2017-06-27

    Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  3. What do standard radiography and clinical examination tell about the shoulder with cuff tear arthropathy?

    Directory of Open Access Journals (Sweden)

    Favard Luc

    2011-01-01

    Full Text Available Abstract Background This study evaluates the preoperative conventional anteroposterior radiography and clinical testing in non-operated patients with cuff tear arthropathy. It analyses the radiological findings in relation to the status of the rotator cuff and clinical status as also the clinical testing in relation to the rotator cuff quality. The aim of the study is to define the usefulness of radiography and clinical examination in cuff tear arthropathy. Methods This study analyses the preoperative radiological (AP-view, (Artro-CT-scan or MRI-scan and clinical characteristics (Constant-Murley-score plus active and passive mobility testing and the peroperative findings in a cohort of 307 patients. These patients were part of a multicenter, retrospective, consecutive study of the French Orthopaedic Society (SOFCOT-2006. All patients had no surgical antecedents and were all treated with prosthetic shoulder surgery for a painful irreparable cuff tear arthropathy (reverse-(84% or hemi-(8% or double cup-bipolar prosthesis (8%. Results A positive significancy could be found for the relationship between clinical testing and the rotator cuff quality; between acromiohumeral distance and posterior rotator cuff quality; between femoralization and posterior rotator cuff quality. Conclusion A conventional antero-posterior radiograph can not provide any predictive information on the clinical status of the patient. The subscapular muscle can be well tested by the press belly test and the teres minor muscle can be well tested by the hornblower' sign and by the exorotation lag signs. The upward migration index and the presence of femoralization are good indicators for the evaluation of the posterior rotator cuff. An inferior coracoid tip positioning suggests rotator cuff disease.

  4. Performance of Multi Walled Carbon Nanotubes Grown on Conductive Substrates as Supercapacitors Electrodes using Organic and Ionic liquid electrolytes

    Science.gov (United States)

    Winchester, Andrew; Ghosh, Sujoy; Turner, Ben; Zhang, X. F.; Talapatra, Saikat

    2012-02-01

    In this work we will present the use of Multi Walled Carbon Nanotubes (MWNT) directly grown on inconel substrates via chemical vapor deposition, as electrode materials for electrochemical double layer capacitors (EDLC). The performance of the MWNT EDLC electrodes were investigated using two electrolytes, an organic electrolyte, tetraethylammonium tetrafluoroborate in propylene carbonate (Et4NBF4 in PC), and a room temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6). Cyclic voltammetry, galvanostatic charge-discharge, and electrochemical impedance spectroscopy measurements to obtain values for the capacitance and internal resistance of these devices will be presented and compared.

  5. An SFG and DFG investigation of polycrystalline Au, Au-Cu and Au-Ag-Cu electrodes in contact with aqueous solutions containing KCN

    International Nuclear Information System (INIS)

    Bozzini, Benedetto; Busson, Bertrand; De Gaudenzi, Gian Pietro; Mele, Claudio; Tadjeddine, Abderrahmane

    2007-01-01

    In this paper, the behaviour of polycrystalline Au, Au-Cu (Cu 25%) and Au-Ag-Cu (Ag 10%, Cu 15%) electrodes in contact with neutral aqueous solutions of KCN has been studied as a function of potential by means of in situ sum frequency generation (SFG) and difference frequency generation (DFG) spectroscopies. The potential-dependent spectra have been analysed quantitatively with a model for the second-order non-linear susceptibility accounting for vibrational and electronic effects. The potential-dependence of the CN - stretching band position and of the free-electron contribution to the real part of the non-resonant component of the second-order susceptibility have been accounted for. Spectroelectrochemical results were complemented by cyclic voltammetric measurements. The chief stress in this work has been placed on systematising and quantifying the interaction between the vibrational and electronic structures of the electrodic interfaces studied. The effects of adsorbates on the electronic structure of the adsorbing electrode, as a function of electrode alloy composition and applied potential are particularly critical for the understanding of Au-alloy electrochemistry in the presence of cyanide and cyanocomplexes. The systematic comparison of SFG and DFG spectra measured under the same electrochemical conditions for Au, Au-Cu and Au-Ag-Cu electrodes discloses a rich phenomenology related to the electronic structure of the interface

  6. An SFG and DFG investigation of polycrystalline Au, Au-Cu and Au-Ag-Cu electrodes in contact with aqueous solutions containing KCN

    Energy Technology Data Exchange (ETDEWEB)

    Bozzini, Benedetto [Dipartimento di Ingegneria dell' Innovazione, Universita di Lecce, v. Monteroni, I-73100 Lecce (Italy)]. E-mail: benedetto.bozzini@unile.it; Busson, Bertrand [CLIO-LCP, Universite Paris-Sud, 91405 Orsay Cedex (France); De Gaudenzi, Gian Pietro [Dipartimento di Ingegneria dell' Innovazione, Universita di Lecce, v. Monteroni, I-73100 Lecce (Italy); Mele, Claudio [Dipartimento di Ingegneria dell' Innovazione, Universita di Lecce, v. Monteroni, I-73100 Lecce (Italy); Tadjeddine, Abderrahmane [UDIL-CNRS, Bat. 201, Centre Universitaire Paris-Sud, BP 34, 91898 Orsay Cedex (France)

    2007-01-16

    In this paper, the behaviour of polycrystalline Au, Au-Cu (Cu 25%) and Au-Ag-Cu (Ag 10%, Cu 15%) electrodes in contact with neutral aqueous solutions of KCN has been studied as a function of potential by means of in situ sum frequency generation (SFG) and difference frequency generation (DFG) spectroscopies. The potential-dependent spectra have been analysed quantitatively with a model for the second-order non-linear susceptibility accounting for vibrational and electronic effects. The potential-dependence of the CN{sup -} stretching band position and of the free-electron contribution to the real part of the non-resonant component of the second-order susceptibility have been accounted for. Spectroelectrochemical results were complemented by cyclic voltammetric measurements. The chief stress in this work has been placed on systematising and quantifying the interaction between the vibrational and electronic structures of the electrodic interfaces studied. The effects of adsorbates on the electronic structure of the adsorbing electrode, as a function of electrode alloy composition and applied potential are particularly critical for the understanding of Au-alloy electrochemistry in the presence of cyanide and cyanocomplexes. The systematic comparison of SFG and DFG spectra measured under the same electrochemical conditions for Au, Au-Cu and Au-Ag-Cu electrodes discloses a rich phenomenology related to the electronic structure of the interface.

  7. Can arthroscopic rotator cuff repair prevent proximal migration of the humeral head?

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz

    2015-12-01

    Full Text Available Introduction: Shoulder arthroscopy has become increasingly used in recent years, especially in rotator cuff repair. The purpose of this study was to determine whether arthroscopic rotator cuff repair could prevent proximal migration of the humeral head. Material and Methods: We performed a retrospective study of 56 patients suffering from shoulder pain. They were divided into two groups, one comprising patients with impingement syndrome who underwent acromioplasty only and another comprising patients with rotator cuff tear who underwent acromioplasty combined with rotator cuff repair. The pre-operative Hirooka angle and the results of the simple shoulder test (SST were compared after 1 year. Results: We found no differences between the groups for the Hirooka angle or SST results. We did find a significant difference (P<0.05 between pre-operative and post-operative SST results. Conclusions: Rotator cuff repair using arthroscopy is a minimally invasive procedure that improves function and prevents proximal migration of the humeral head after 1 year of follow-up. [Arch Clin Exp Surg 2015; 4(4.000: 190-195

  8. Case Report of Multiple Tracheostomy Revisions due to Persistent, Recurrent Cuff Leak

    Directory of Open Access Journals (Sweden)

    Jian P. Azimi-Bolourian

    2015-01-01

    Full Text Available This case is a patient with amyotrophic lateral sclerosis who was unable to be separated from mechanical ventilator support and required a tracheostomy. The patient underwent an initial open tracheostomy utilizing flexible fiberoptic tracheoscopy (FFT in the operating room (OR. Subsequently, he developed recurrent leaks in the tracheal tube cuff requiring multiple trips back to the operating room. The recurrent cuff leak occurred following each tube placement until the etiology of the leak was discovered during the fourth procedure. In the fourth procedure, the wound was explored more extensively, and it was found that there was a sharp, calcified, aberrant fragment of a tracheal cartilage ring protruding into the tracheal lumen, which was damaging the cuff of each tube. This fragment was not visible by multiple FFTs, nor was it visible in the wound by the surgeons until wider exploration of the wound occurred. The cartilage fragment was ultimately excised and the patient had no further cuff leaks. Aberrant tracheal cartilage should be on the differential diagnosis for cuff leaks subsequent to surgical tracheostomy (ST or percutaneous dilatational tracheostomy (PDT.

  9. Cuff size influences blood pressure measurement in obese children and adolescents

    DEFF Research Database (Denmark)

    Muhamed, P. K.; Olsen, M. H.; Holm, Jens-Christian

    2016-01-01

    Introduction: Recently, we established that a group ofobese children and adolescents had a higher blood pressure(BP) than a healthy control group. In the present study, weinvestigate whether the higher BP in the obese group wasinfluenced by BP cuff sizes.Methods: A total of 104 obese patients aged...... sizes had a significant impact on BP measurements.Despite the influence of cuff size, multiple regressionanalyses revealed that systolic BP was 68 mmHg higherand diastolic BP 32 mmHg higher in the obese groupthan in the control group. A step function, i.e. a sudden fallin BP, was seen at the point...... of switching from small to mediumcuff size in the control group, which suggests that systolicBP was overestimated when using small cuff size andunderestimated when using medium cuff size in subjectswith an AC near 23 cm.Conclusions: BP was higher in the obese group than inthe control group although BP...

  10. Optimising carbon electrode materials for adsorptive stripping voltammetry

    OpenAIRE

    Chaisiwamongkhol, K; Batchelor-McAuley, C; Sokolov, S; Holter, J; Young, N; Compton, R

    2017-01-01

    Different types of carbon electrode materials for adsorptive stripping voltammetry are studied through the use of cyclic voltammetry. Capsaicin is utilised as a model compound for adsorptive stripping voltammetry using unmodified and modified basal plane pyrolytic graphite (BPPG) electrodes modified with multi-walled carbon nanotubes, carbon black or graphene nanoplatelets, screen printed carbon electrodes (SPE), carbon nanotube modified screen printed electrodes, and carbon paste electrodes....

  11. Modiolus-Hugging Intracochlear Electrode Array with Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Kyou Sik Min

    2013-01-01

    Full Text Available In the cochlear implant system, the distance between spiral ganglia and the electrodes within the volume of the scala tympani cavity significantly affects the efficiency of the electrical stimulation in terms of the threshold current level and spatial selectivity. Because the spiral ganglia are situated inside the modiolus, the central axis of the cochlea, it is desirable that the electrode array hugs the modiolus to minimize the distance between the electrodes and the ganglia. In the present study, we propose a shape-memory-alloy-(SMA- embedded intracochlear electrode which gives a straight electrode a curved modiolus-hugging shape using the restoration force of the SMA as triggered by resistive heating after insertion into the cochlea. An eight-channel ball-type electrode array is fabricated with an embedded titanium-nickel SMA backbone wire. It is demonstrated that the electrode array changes its shape in a transparent plastic human cochlear model. To verify the safe insertion of the electrode array into the human cochlea, the contact pressures during insertion at the electrode tip and the contact pressures over the electrode length after insertion were calculated using a 3D finite element analysis. The results indicate that the SMA-embedded electrode is functionally and mechanically feasible for clinical applications.

  12. Transition metal doped poly(aniline-co-pyrrole)/multi-walled carbon nanotubes nanocomposite for high performance supercapacitor electrode materials

    Energy Technology Data Exchange (ETDEWEB)

    Dhibar, Saptarshi; Bhattacharya, Pallab; Hatui, Goutam; Das, C.K., E-mail: chapal12@yahoo.co.in

    2015-03-15

    Highlights: • The CuCl{sub 2} doped copolymer (PANI and PPy)/MWCNTs nanocomposite was prepared. • The nanocomposite achieved highest specific capacitance of 383 F/g at a 0.5 A/g. • Nanocomposite exhibits better energy density as well as power density. • The nanocomposite also showed better electrical conductivity at room temperature. • The nanocomposite can be used as promising electrode materials for supercapacitor. - Abstract: In this present communication, copolymer of polyaniline (PANI) and polypyrrole (PPy) that is poly(aniline-co-pyrrole) [poly(An-co-Py)], copper chloride (CuCl{sub 2}) doped poly(aniline-co-pyrrole) [poly(An-co-Py) Cu], and CuCl{sub 2} doped poly(aniline-co-pyrrole)/multi walled carbon nanotubes (MWCNTs) [poly(An-co-Py) Cu CNT] nanocomposite have been prepared by a simple and inexpensive in-situ chemical oxidative polymerization method, using ammonium persulfate (APS) as oxidant and hydrochloric acid (HCl) as dopant and investigated as high performance supercapacitor electrode materials. The possible interaction between CuCl{sub 2} with copolymers and MWCNTs was investigated by Fourier transform infrared spectroscopy (FTIR) and UV–visible spectroscopy analysis. The morphological characteristic of all the electrode materials were analyzed by Field emission scanning electron microscopy (FESEM) and Transmission electron microscopy (TEM) study. The electrochemical characterizations of all the electrode materials were carried out by three electrode probe method where, standard calomel electrode and platinum were used as reference and counter electrodes, respectively. Among all the electrode materials, poly(An-co-Py) Cu CNT nanocomposite achieved highest specific capacitance value of 383 F/g at 0.5 A/g scan rate. The nanocomposite showed better electrical conductivity at room temperature and also attained nonlinear current–voltage characteristic. Based on the superior electrochemical as well as other properties the as prepared

  13. Transition metal doped poly(aniline-co-pyrrole)/multi-walled carbon nanotubes nanocomposite for high performance supercapacitor electrode materials

    International Nuclear Information System (INIS)

    Dhibar, Saptarshi; Bhattacharya, Pallab; Hatui, Goutam; Das, C.K.

    2015-01-01

    Highlights: • The CuCl 2 doped copolymer (PANI and PPy)/MWCNTs nanocomposite was prepared. • The nanocomposite achieved highest specific capacitance of 383 F/g at a 0.5 A/g. • Nanocomposite exhibits better energy density as well as power density. • The nanocomposite also showed better electrical conductivity at room temperature. • The nanocomposite can be used as promising electrode materials for supercapacitor. - Abstract: In this present communication, copolymer of polyaniline (PANI) and polypyrrole (PPy) that is poly(aniline-co-pyrrole) [poly(An-co-Py)], copper chloride (CuCl 2 ) doped poly(aniline-co-pyrrole) [poly(An-co-Py) Cu], and CuCl 2 doped poly(aniline-co-pyrrole)/multi walled carbon nanotubes (MWCNTs) [poly(An-co-Py) Cu CNT] nanocomposite have been prepared by a simple and inexpensive in-situ chemical oxidative polymerization method, using ammonium persulfate (APS) as oxidant and hydrochloric acid (HCl) as dopant and investigated as high performance supercapacitor electrode materials. The possible interaction between CuCl 2 with copolymers and MWCNTs was investigated by Fourier transform infrared spectroscopy (FTIR) and UV–visible spectroscopy analysis. The morphological characteristic of all the electrode materials were analyzed by Field emission scanning electron microscopy (FESEM) and Transmission electron microscopy (TEM) study. The electrochemical characterizations of all the electrode materials were carried out by three electrode probe method where, standard calomel electrode and platinum were used as reference and counter electrodes, respectively. Among all the electrode materials, poly(An-co-Py) Cu CNT nanocomposite achieved highest specific capacitance value of 383 F/g at 0.5 A/g scan rate. The nanocomposite showed better electrical conductivity at room temperature and also attained nonlinear current–voltage characteristic. Based on the superior electrochemical as well as other properties the as prepared nanocomposite can be used

  14. Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row.

    Science.gov (United States)

    Mall, Nathan A; Lee, Andrew S; Chahal, Jaskarndip; Van Thiel, Geoffrey S; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2013-02-01

    Double-row and transosseous-equivalent repair techniques have shown greater strength and improved healing than single-row techniques. The purpose of this study was to determine whether tying of the medial-row sutures provides added stability during biomechanical testing of a transosseous-equivalent rotator cuff repair. We performed a systematic review of studies directly comparing biomechanical differences. Five studies met the inclusion and exclusion criteria. Of the 5 studies, 4 showed improved biomechanical properties with tying the medial-row anchors before bringing the sutures laterally to the lateral-row anchors, whereas the remaining study showed no difference in contact pressure, mean failure load, or gap formation with a standard suture bridge with knots tied at the medial row compared with knotless repairs. The results of this systematic review and quantitative synthesis indicate that the biomechanical factors ultimate load, stiffness, gap formation, and contact area are significantly improved when medial knots are tied as part of a transosseous-equivalent suture bridge construct compared with knotless constructs. Further studies comparing the clinical healing rates and functional outcomes between medial knotted and knotless repair techniques are needed. This review indicates that biomechanical factors are improved when the medial row of a transosseous-equivalent rotator cuff is tied compared with a knotless repair. However, this has not been definitively proven to translate to improved healing rates clinically. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. The greater tuberosity angle: a new predictor for rotator cuff tear.

    Science.gov (United States)

    Cunningham, Gregory; Nicodème-Paulin, Emilie; Smith, Margaret M; Holzer, Nicolas; Cass, Benjamin; Young, Allan A

    2018-04-24

    The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P rotator cuff tear (P rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  16. Contact ionization ion source

    International Nuclear Information System (INIS)

    Hashmi, N.; Van Der Houven Van Oordt, A.J.

    1975-01-01

    An ion source in which an apertured or foraminous electrode having a multiplicity of openings is spaced from one or more active surfaces of an ionisation electrode, the active surfaces comprising a material capable of ionising by contact ionization a substance to be ionized supplied during operation to the active surface or surfaces comprises means for producing during operation a magnetic field which enables a stable plasma to be formed in the space between the active surface or surfaces and the apertured electrode, the field strength of the magnetic field being preferably in the range between 2 and 8 kilogauss. (U.S.)

  17. Low voltage initiation of damaging arcs between electrical contacts

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1975-07-01

    Metallic arcs were found to precede the firm contacting of electrical contacts which were closed without bounce. When the open-circuit voltages were below the ionization potential, the initiation of these arcs was found to depend on the presence of asperities on the surfaces and on asperity contracting, melting, and pinching off by magnetic forces. The arc is thought to be initiated inductively when the molten metallic asperity contact is pinched off, and the electrode damage is similar to that produced by the arcing of opening contacts. Arcing could not be produced for exceptionally smooth surfaces, or, for rough surfaces when the open-circuit potential was below the melting voltages of the electrode metals. In order to prevent damage to contact surfaces by melting or arcing, it is suggested that test potentials be limited to below the melting voltages, that the current be limited, the test circuits be designed to prevent inductively generated high voltage transients, and the contact surfaces be very smooth. In order to facilitate arc initiation in arc welding applications, it is suggested that the surfaces of electrodes and work pieces be roughened. (U.S.)

  18. Sulfur tolerant composite cermet electrodes for solid oxide electrochemical cells

    Science.gov (United States)

    Isenberg, Arnold O.

    1987-01-01

    An electrochemical apparatus is made containing an exterior electrode bonded to the exterior of a tubular, solid, oxygen ion conducting electrolyte where the electrolyte is also in contact with an interior electrode, said exterior electrode comprising particles of an electronic conductor contacting the electrolyte, where a ceramic metal oxide coating partially surrounds the particles and is bonded to the electrolyte, and where a coating of an ionic-electronic conductive material is attached to the ceramic metal oxide coating and to the exposed portions of the particles.

  19. Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy.

    Directory of Open Access Journals (Sweden)

    Hio Teng Leong

    Full Text Available Although excessive tension of the upper trapezius (UT is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1 to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2 to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002, regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001. When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008 and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002 was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001. Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy.

  20. Differences of RNA Expression in the Tendon According to Anatomic Outcomes in Rotator Cuff Repair.

    Science.gov (United States)

    Ahn, Jin-Ok; Chung, Jin-Young; Kim, Do Hoon; Im, Wooseok; Kim, Sae Hoon

    2017-11-01

    Despite increased understanding of the pathophysiology of rotator cuff tears and the evolution of rotator cuff repair, healing failure remains a substantial problem. The critical roles played by biological factors have been emphasized, but little is known of the implications of gene expression profile differences at the time of repair. To document the relationship between the perioperative gene expression of healed and unhealed rotator cuffs by RNA microarray analysis. Case-control study; Level of evidence, 3. Superior (supraspinatus involvement) and posterosuperior (supraspinatus and infraspinatus involvement) tears were included in the study. Samples of rotator cuff tendons were prospectively collected during rotator cuff surgery. Three samples were harvested at the tendon ends of tears from the anterior, middle (apex), and posterior parts using an arthroscopic punch. Seven patients with an unhealed rotator cuff were matched one-to-one with patients with a healed rotator cuff by sex, age, tear size, and fatty degeneration of rotator cuff muscles. mRNA microarray analysis was used to identify genetic differences between healed and unhealed rotator cuff tendons. Gene ontology and gene association files were obtained from the Gene Ontology Consortium, and the Gene Ontology system in DAVID was used to identify enhanced biological processes. Microarray analyses identified 262 genes that were differentially expressed by at least 1.5-fold between the healed and unhealed groups. Overall, in the healed group, 103 genes were significantly downregulated, and 159 were significantly upregulated. DAVID Functional Annotation Cluster analysis showed that in the healed group, the genes most upregulated were related to the G protein-coupled receptor protein signaling pathway and to the neurological system. On the other hand, the genes most downregulated were related to immune and inflammatory responses. BMP5 was the gene most upregulated in the healed group, and the majority of

  1. Dynamic Three-Dimensional Shoulder Mri during Active Motion for Investigation of Rotator Cuff Diseases.

    Directory of Open Access Journals (Sweden)

    Christine Tempelaere

    Full Text Available MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases.Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI.The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear and without tears (tendinopathy (p = 0.012. The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm than in normals (3.4mm (p = 0.02. The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm and supraspinatus tear (9.3 mm shoulders compared to normals (3.5mm and tendinopathy (4.8mm shoulders (p = 0.05.The Dynamic MRI enabled a novel measure; 'Looseness', i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position.

  2. Electrospun fibrous electrodes with tunable microstructure made of polyaniline/multi-walled carbon nanotube suspension for all-solid-state supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Junsheng; Su, Shijie; Fang, Xu [Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116023 (China); Wang, Dazhi, E-mail: d.wang@dlut.edu.cn [Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116023 (China); Key Laboratory for Precision and Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, Dalian 116023 (China); Xu, Shuangchao [Key Laboratory for Precision and Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, Dalian 116023 (China)

    2016-09-15

    Highlights: • Electrospun PANI/MWCNT fibrous electrodes for supercapacitor were prepared. • Microstructure of electrodes is tunable by changing the electrospin parameters. • Fiber-diameter dependence of the electrode performance was observed. • High performance and good stability of electrospun electrodes were obtained. - Abstract: Electrospinning technique was used to prepare high performance fibrous electrodes with tunable microstructure for all-solid-state electrochemical supercapacitor. Symmetrically sandwiched supercapacitors consisting of flexible electrospun polyaniline (PANI)/multi-walled carbon nanotube (MWCNT) electrodes and polyvinyl alcohol (PVA)/sulfuric acid (H{sub 2}SO{sub 4}) gel electrolyte were assembled. Tunable microstructure of the fibrous electrode was obtained by changing the electrospinning parameters including the collector–needle distance (CND) and the suspension flow rate (SFR). Results show that, higher CND combining with lower SFR can result in a smaller average diameter of the electrospun fibers and hence improve the electrode performance. When the CND changes from 80 to 140 mm, the average fiber diameter will decrease from 2.89 to 1.21 μm, and the specific surface area of the electrode can increase from 57 to 83 m{sup 2}·g{sup −1}. The corresponding specific capacitance of the electrospun electrode will therefore increase from 129.5 to 180 F·g{sup −1}, leading to a synchronous improvement of the energy density of the supercapacitor from 18 to 25 Wh·kg{sup −1}. On the other hand, the supercapacitors using fibrous electrodes in this work also show good rate capability and cycling stability. Using the electrode with an average fiber diameter of 1.21 μm, the specific capacitances can maintain 131 F·g{sup −1} at a current density of 4 A·g{sup −1}, which is 73% of the specific capacitance of the same sample at a current density of 0.5 A·g{sup −1}. And the specific capacitance of the electrode can retain 89

  3. Electrospun fibrous electrodes with tunable microstructure made of polyaniline/multi-walled carbon nanotube suspension for all-solid-state supercapacitors

    International Nuclear Information System (INIS)

    Liang, Junsheng; Su, Shijie; Fang, Xu; Wang, Dazhi; Xu, Shuangchao

    2016-01-01

    Highlights: • Electrospun PANI/MWCNT fibrous electrodes for supercapacitor were prepared. • Microstructure of electrodes is tunable by changing the electrospin parameters. • Fiber-diameter dependence of the electrode performance was observed. • High performance and good stability of electrospun electrodes were obtained. - Abstract: Electrospinning technique was used to prepare high performance fibrous electrodes with tunable microstructure for all-solid-state electrochemical supercapacitor. Symmetrically sandwiched supercapacitors consisting of flexible electrospun polyaniline (PANI)/multi-walled carbon nanotube (MWCNT) electrodes and polyvinyl alcohol (PVA)/sulfuric acid (H_2SO_4) gel electrolyte were assembled. Tunable microstructure of the fibrous electrode was obtained by changing the electrospinning parameters including the collector–needle distance (CND) and the suspension flow rate (SFR). Results show that, higher CND combining with lower SFR can result in a smaller average diameter of the electrospun fibers and hence improve the electrode performance. When the CND changes from 80 to 140 mm, the average fiber diameter will decrease from 2.89 to 1.21 μm, and the specific surface area of the electrode can increase from 57 to 83 m"2·g"−"1. The corresponding specific capacitance of the electrospun electrode will therefore increase from 129.5 to 180 F·g"−"1, leading to a synchronous improvement of the energy density of the supercapacitor from 18 to 25 Wh·kg"−"1. On the other hand, the supercapacitors using fibrous electrodes in this work also show good rate capability and cycling stability. Using the electrode with an average fiber diameter of 1.21 μm, the specific capacitances can maintain 131 F·g"−"1 at a current density of 4 A·g"−"1, which is 73% of the specific capacitance of the same sample at a current density of 0.5 A·g"−"1. And the specific capacitance of the electrode can retain 89% after 1500 charge/discharge cycles.

  4. [A design and study of a novel electronic device for cuff-pressure monitoring].

    Science.gov (United States)

    Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang

    2017-06-01

    To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P

  5. Rat rotator cuff muscle responds differently from hindlimb muscle to a combined tendon-nerve injury.

    Science.gov (United States)

    Davies, Michael R; Ravishankar, Bharat; Laron, Dominique; Kim, Hubert T; Liu, Xuhui; Feeley, Brian T

    2015-07-01

    Rotator cuff tears (RCTs) are among the most common musculoskeletal injuries seen by orthopaedic surgeons. Clinically, massive cuff tears lead to unique pathophysiological changes in rotator cuff muscle, including atrophy, and massive fatty infiltration, which are rarely seen in other skeletal muscles. Studies in a rodent model for RCT have demonstrated that these histologic findings are accompanied by activation of the Akt/mammalian target of rapamycin (mTOR) and transforming growth factor-β (TGF-β) pathways following combined tendon-nerve injury. The purpose of this study was to compare the histologic and molecular features of rotator cuff muscle and gastrocnemius muscle--a major hindlimb muscle, following combined tendon-nerve injury. Six weeks after injury, the rat gastrocnemius did not exhibit notable fatty infiltration compared to the rotator cuff. Likewise, the adipogenic markers SREBP-1 and PPARγ as well as the TGF-β canonical pathway were upregulated in the rotator cuff, but not the gastrocnemius. Our study suggests that the rat rotator cuff and hindlimb muscles differ significantly in their response to a combined tendon-nerve injury. Clinically, these findings highlight the unique response of the rotator cuff to injury, and may begin to explain the poor outcomes of massive RCTs compared to other muscle-tendon injuries. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Tendon patch grafting using the long head of the biceps for irreparable massive rotator cuff tears

    International Nuclear Information System (INIS)

    Sano, Hirotaka; Itoi, Eiji; Mineta, Mitsuyoshi; Kita, Atsushi

    2010-01-01

    Surgical treatment of massive rotator cuff tears is challenging for shoulder surgeons. The purpose of this study was to investigate both clinical outcomes and cuff integrity after tendon patch grafting using the long head of the biceps (LHB) tendon for irreparable massive rotator cuff tears. A short deltoid splitting approach was used to expose the torn cuff tendon stump. After tenodesis of the LHB tendon, its intraarticular portion was resected. If the size of the harvested tendon was smaller than that of the cuff defect, it was split into two layers. Then, the LHB tendon was sutured to the remnant cuff tendons and fixed to the footprint using the transosseous suture technique. A total of 14 patients (12 men, 2 women; average age 64 years) underwent this procedure. The average postoperative follow-up period was 28 months (range 12-51 months). Active elevation angle of the shoulder as well as the Japanese Orthopaedic Association (JOA) score were assessed before surgery and at the time of follow-up. Postoperative cuff integrity was assessed using T2-weighted magnetic resonance imaging (MRI). All cuff defects were successfully closed with this technique. Average active elevation angle improved from 69deg to 149deg. Total JOA score also improved from 54.7 points to 83.1 points. Thirteen shoulders showed no re-tearing on T2-weighted MRI; a minor discontinuity of the repaired cuff tendon was observed in the other shoulder. The LHB tendon is available in case tenodesis or tenotomy is needed. The resected tendon may be used as a graft for rotator cuff repair without any additional skin incision, which could reduce both the surgical invasion and the risk of infection. The LHB tendon patch grafting may be one of the useful options for surgical treatment of irreparable massive rotator cuff tears. (author)

  7. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Martin [Southmead Hospital, Department of Radiology, Westbury-on-Trym, Bristol (United Kingdom); Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S. [University of Alberta Hospital, Department of Radiology and Diagnostic Imaging, Edmonton (Canada)

    2006-12-15

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  8. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    International Nuclear Information System (INIS)

    Williams, Martin; Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S.

    2006-01-01

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  9. Contact resistance and stability study for Au, Ti, Hf and Ni contacts on thin-film Mg2Si

    KAUST Repository

    Zhang, Bo; Zheng, Tao; Wang, Qingxiao; Zhu, Yihan; Alshareef, Husam N.; Kim, Moon J.; Gnade, Bruce E.

    2016-01-01

    We present a detailed study of post-deposition annealing effects on contact resistance of Au, Ti, Hf and Ni electrodes on Mg2Si thin films. Thin-film Mg2Si and metal contacts were deposited using magnetron sputtering. Various post

  10. Plasma assisted fabrication of multi-layer graphene/nickel hybrid film as enhanced micro-supercapacitor electrodes

    Science.gov (United States)

    Ding, Q.; Li, W. L.; Zhao, W. L.; Wang, J. Y.; Xing, Y. P.; Li, X.; Xue, T.; Qi, W.; Zhang, K. L.; Yang, Z. C.; Zhao, J. S.

    2017-03-01

    A facile synthesis strategy has been developed for fabricating multi-layer graphene/nickel hybrid film as micro-supercapacitor electrodes by using plasma enhanced chemical vapor deposition. The as-presented method is advantageous for rapid graphene growth at relatively low temperature of 650 °C. In addition, after pre-treating for the as-deposited nickel film by using argon plasma bombardment, the surface-to-volume ratio of graphene film on the treated nickel substrate is effectively increased by the increasing of surface roughness. This is demonstrated by the characterization results from transmission electron microscopy, scanning electron microscope and atomic force microscopy. Moreover, the electrochemical performance of the resultant graphene/nickel hybrid film as micro-supercapacitor working electrode was investigated by cyclic voltammetry and galvanostatic charge/discharge measurements. It was found that the increase of the surface-to-volume ratio of graphene/nickel hybrid film improved the specific capacitance of 10 times as the working electrode of micro-supercapacitor. Finally, by using comb columnar shadow mask pattern, the micro-supercapacitor full cell device was fabricated. The electrochemical performance measurements of the micro-supercapacitor devices indicate that the method presented in this study provides an effective way to fabricate micro-supercapacitor device with enhanced energy storage property.

  11. Result from arthroscopic surgical treatment of renewed tearing of the rotator cuff of the shoulder

    Directory of Open Access Journals (Sweden)

    Glaydson Gomes Godinho

    2015-02-01

    Full Text Available OBJECTIVES: To evaluate function among patients with postoperative recurrence of rotator cuff injuries that was treated arthroscopically (case series and compare this with function in patients without recurrence (control group; and to compare function among patients with recurrence of rotator cuff injuries that were greater than and smaller than 3 cm.METHODS: This was a retrospective evaluation of patients who underwent arthroscopic revision of rotator cuff injuries using the ASES, Constant & Murley and UCLA scores and a visual analog pain scale, in comparison with patients in a control group who underwent primary rotator cuff repair.RESULTS: The size of the rotator cuff injury recurrence had a statistically significant influence on the result from the arthroscopic surgical treatment. The functional scores showed worse results than those from the first procedure.CONCLUSION: Arthroscopic surgical treatment of renewed tearing of rotator cuff injuries showed worse functional scores than those from primary repair of the injury.

  12. Variable RF capacitor based on a-Si:H (P-doped) multi-length cantilevers

    International Nuclear Information System (INIS)

    Fu, Y Q; Milne, S B; Luo, J K; Flewitt, A J; Wang, L; Miao, J M; Milne, W I

    2006-01-01

    A variable RF capacitor with a-Si:H (doped with phosphine) cantilevers as the top electrode were designed and fabricated. Because the top multi-cantilever electrodes have different lengths, increasing the applied voltage pulled down the cantilever beams sequentially, thus realizing a gradual increase of the capacitance with the applied voltage. A high-k material, H f O 2 , was used as an insulating layer to increase the tuning range of the capacitance. The measured capacitance from the fabricated capacitor was much lower and the pull-in voltage was much higher than those from theoretical analysis because of incomplete contact of the two electrodes, existence of film differential stresses and charge injection effect. Increase of sweeping voltage rate could significantly shift the pull-in voltage to higher values due to the charge injection mechanisms

  13. Early versus delayed rehabilitation following arthroscopic rotator cuff repair: A systematic review.

    Science.gov (United States)

    Gallagher, Brian P; Bishop, Meghan E; Tjoumakaris, Fotios P; Freedman, Kevin B

    2015-05-01

    Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. Our purpose was to perform a systematic review to determine if there are differences between early and delayed rehabilitation after arthroscopic rotator cuff repair in terms of clinical outcomes and healing. We performed a literature search with the terms 'arthroscopic rotator cuff', 'immobilization', 'early', 'delayed', 'late', and 'rehabilitation' using PubMed, Cochrane Central Register of Controlled Trials, and EMBASE. Selection criteria included: level I/II evidence ≤ 6 months in duration, comparing early versus delayed rehabilitation following arthroscopic repair. Data regarding demographics, sample sizes, duration, cuff pathology, surgery, rehabilitation, functional outcomes, pain, ROM and anatomic assessment of healing were analyzed. PRIMSA criteria were followed. We identified six articles matching our criteria. Three reported significantly increased functional scores within the first 3-6 months with early rehabilitation compared to the delayed group, only one of which continued to observe a difference at a final follow-up of 15 months. Four articles showed improved ROM in the first 3-6 months post-operatively with early rehabilitation. One noted transient differences in pain scores. Only one study noted significant differences in ROM at final follow-up. No study reported any significant difference in rates of rotator cuff re-tear. However, two studies noted a trend towards increased re-tear with early rehabilitation that did not reach significance. This was more pronounced in studies including medium-large tears. Early rehabilitation after arthroscopic cuff repair is associated with some initial improvements in ROM and function. Ultimately, similar clinical and anatomical outcomes between groups existed at 1 year. While there was no

  14. The coracoacromial arch: MR evaluation and correlation with rotator cuff pathology

    International Nuclear Information System (INIS)

    Farley, T.E.; Neumann, C.H.; Steinbach, L.S.; Petersen, S.A.

    1994-01-01

    The relative prevalence of various acromial shapes, appearance of the coracoacromial ligament and enthesophytes along the inferior aspect of the acromioclavicular joint in patients with and without rotator cuff tears were evaluated. Of 76 patients with clinical instability and impingement, 31 had a normal rotator cuff and 45 demonstrated a partial or full tear of the supraspinatus tendon at surgery. Results were compared with those from magnetic resonance (MR) scans of 57 asymptomatic volunteers. Of the 45 patients with a supraspinatus tear, 38% (17) had a flat acromial undersurface (type I), 40% (18) had a concave acromial undersurface (type II), 18% (8) had an anteriorly hooked acromion (type III), and 4% (2) had an inferiorly convex acromion (type IV). Among the 31 patients with a normal rotator cuff at surgery and the 57 asymptomatic volunteers, the respective prevalences of the type I acromion were 39% (12) and 44% (25), of type II 48% (15) and 35% (20), type III 3% (1) and 12% (7), and type IV 10% (3) and 9% (5). Shoulders with surgically proven rotator cuff tears showed a tendential association with a type III acromion (8/45) and statistically significant associations with a thickened coracoacromial ligament (17/45) and acromioclavicular enthesophytes (18/45). For the association between inferiorly directed acromioclavicular joint enthesophytes and rotator cuff tears, age appears to be a confounding factor. The type IV acromion, newly classified by this study, does not have a recognizable association with rotator cuff tears. Assessment of the osseous-ligamentous coracoacromial outlet by MR imaging provides useful diagnostic information and may prove helpful to the orthopedic surgeon in patients for whom surgical decompression is contemplated. (orig.)

  15. The coracoacromial arch: MR evaluation and correlation with rotator cuff pathology

    Energy Technology Data Exchange (ETDEWEB)

    Farley, T.E. [San Francisco Magnetic Resonance Center, San Francisco, CA (United States)]|[Florida Hospital, Dept. of Diagnostic Radiology, Orlando, FL (United States); Neumann, C.H. [San Francisco Magnetic Resonance Center, San Francisco, CA (United States)]|[Desert Hospital, Dept. of Radiology, Palm Springs, CA (United States)]|[Univ. of California San Francisco, Dept. of Radiology, San Francisco, CA (United States); Steinbach, L.S. [Univ. of California San Francisco, Dept. of Radiology, San Francisco, CA (United States); Petersen, S.A. [Wayne State Univ. School of Medicine, Dept. of Orthopedic Surgery, Detroit, MI (United States)

    1994-11-01

    The relative prevalence of various acromial shapes, appearance of the coracoacromial ligament and enthesophytes along the inferior aspect of the acromioclavicular joint in patients with and without rotator cuff tears were evaluated. Of 76 patients with clinical instability and impingement, 31 had a normal rotator cuff and 45 demonstrated a partial or full tear of the supraspinatus tendon at surgery. Results were compared with those from magnetic resonance (MR) scans of 57 asymptomatic volunteers. Of the 45 patients with a supraspinatus tear, 38% (17) had a flat acromial undersurface (type I), 40% (18) had a concave acromial undersurface (type II), 18% (8) had an anteriorly hooked acromion (type III), and 4% (2) had an inferiorly convex acromion (type IV). Among the 31 patients with a normal rotator cuff at surgery and the 57 asymptomatic volunteers, the respective prevalences of the type I acromion were 39% (12) and 44% (25), of type II 48% (15) and 35% (20), type III 3% (1) and 12% (7), and type IV 10% (3) and 9% (5). Shoulders with surgically proven rotator cuff tears showed a tendential association with a type III acromion (8/45) and statistically significant associations with a thickened coracoacromial ligament (17/45) and acromioclavicular enthesophytes (18/45). For the association between inferiorly directed acromioclavicular joint enthesophytes and rotator cuff tears, age appears to be a confounding factor. The type IV acromion, newly classified by this study, does not have a recognizable association with rotator cuff tears. Assessment of the osseous-ligamentous coracoacromial outlet by MR imaging provides useful diagnostic information and may prove helpful to the orthopedic surgeon in patients for whom surgical decompression is contemplated. (orig.)

  16. Unified selective sorting approach to analyse multi-electrode extracellular data

    Science.gov (United States)

    Veerabhadrappa, R.; Lim, C. P.; Nguyen, T. T.; Berk, M.; Tye, S. J.; Monaghan, P.; Nahavandi, S.; Bhatti, A.

    2016-01-01

    Extracellular data analysis has become a quintessential method for understanding the neurophysiological responses to stimuli. This demands stringent techniques owing to the complicated nature of the recording environment. In this paper, we highlight the challenges in extracellular multi-electrode recording and data analysis as well as the limitations pertaining to some of the currently employed methodologies. To address some of the challenges, we present a unified algorithm in the form of selective sorting. Selective sorting is modelled around hypothesized generative model, which addresses the natural phenomena of spikes triggered by an intricate neuronal population. The algorithm incorporates Cepstrum of Bispectrum, ad hoc clustering algorithms, wavelet transforms, least square and correlation concepts which strategically tailors a sequence to characterize and form distinctive clusters. Additionally, we demonstrate the influence of noise modelled wavelets to sort overlapping spikes. The algorithm is evaluated using both raw and synthesized data sets with different levels of complexity and the performances are tabulated for comparison using widely accepted qualitative and quantitative indicators. PMID:27339770

  17. Load response and gap formation in a single-row cruciate suture rotator cuff repair.

    Science.gov (United States)

    Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C

    2017-06-01

    Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.

  18. A Multi-Parametric Device with Innovative Solid Electrodes for Long-Term Monitoring of pH, Redox-Potential and Conductivity in a Nuclear Waste Repository.

    Science.gov (United States)

    Daoudi, Jordan; Betelu, Stephanie; Tzedakis, Theodore; Bertrand, Johan; Ignatiadis, Ioannis

    2017-06-13

    We present an innovative electrochemical probe for the monitoring of pH, redox potential and conductivity in near-field rocks of deep geological radioactive waste repositories. The probe is composed of a monocrystalline antimony electrode for pH sensing, four AgCl/Ag-based reference or Cl - selective electrodes, one Ag₂S/Ag-based reference or S 2- selective electrode, as well as four platinum electrodes, a gold electrode and a glassy-carbon electrode for redox potential measurements. Galvanostatic electrochemistry impedance spectroscopy using AgCl/Ag-based and platinum electrodes measure conductivity. The use of such a multi-parameter probe provides redundant information, based as it is on the simultaneous behaviour under identical conditions of different electrodes of the same material, as well as on that of electrodes made of different materials. This identifies the changes in physical and chemical parameters in a solution, as well as the redox reactions controlling the measured potential, both in the solution and/or at the electrode/solution interface. Understanding the electrochemical behaviour of selected materials thus is a key point of our research, as provides the basis for constructing the abacuses needed for developing robust and reliable field sensors.

  19. Contact resistance problems applying ERT on low bulk density forested stony soils. Is there a solution?

    Science.gov (United States)

    Deraedt, Deborah; Touzé, Camille; Robert, Tanguy; Colinet, Gilles; Degré, Aurore; Garré, Sarah

    2015-04-01

    Electrical resistivity tomography (ERT) has often been put forward as a promising tool to quantify soil water and solute fluxes in a non-invasive way. In our experiment, we wanted to determine preferential flow processes along a forested hillslope using a saline tracer with ERT. The experiment was conducted in the Houille watershed, subcatchment of the Meuse located in the North of Belgian Ardennes (50° 1'52.6'N, 4° 53'22.5'E). The climate is continental but the soil under spruce (Picea abies (L.) Karst.) and Douglas fire stand (Pseudotsuga menziesii (Mirb.) Franco) remains quite dry (19% WVC in average) during the whole year. The soil is Cambisol and the parent rock is Devonian schist covered with variable thickness of silty loam soil. The soil density ranges from 1.13 to 1.87 g/cm3 on average. The stone content varies from 20 to 89% and the soil depth fluctuates between 70 and 130 cm. The ERT tests took place on June 1st 2012, April 1st, 2nd and 3rd 2014 and May 12th 2014. We used the Terrameter LS 12 channels (ABEM, Sweden) in 2012 test and the DAS-1 (Multi-Phase Technologies, United States) in 2014. Different electrode configurations and arrays were adopted for different dates (transect and grid arrays and Wenner - Schlumberger, Wenner alpha and dipole-dipole configurations). During all tests, we systematically faced technical problems, mainly related to bad electrode contact. The recorded data show values of contact resistance above 14873 Ω (our target value would be below 3000 Ω). Subsequently, we tried to improve the contact by predrilling the soil and pouring water in the electrode holes. The contact resistance improved to 14040 Ω as minimum. The same procedure with liquid mud was then tested to prevent quick percolation of the water from the electrode location. As a result, the lower contact resistance dropped to 11745 Ω. Finally, we applied about 25 litre of saline solution (CaCl2, 0.75g/L) homogeneously on the electrode grid. The minimum value of

  20. Arthroscopic rotator cuff repair for the elderly (over 75-years)

    International Nuclear Information System (INIS)

    Ikeda, Rintaro; Furukawa, Keizo; Kajiyama, Shiro; Sakimura, Toshiyuki; Shindo, Hiroyuki; Eto, Masao

    2010-01-01

    The purpose of this study was to evaluate the surgical results of arthroscopic rotator cuff repair (ARCR) and investigate the interoperative complications for elderly people (over 75-years). We evaluated nine patients 75 and over who underwent rotator cuff repair, followed up for more than 12 months, and underwent MRI six months or more after the operation which was performed between December 2004 to July 2008. Their average age was 77.3 years. The control patients were 61 patients less than 75 who underwent ARCR during same term. Their average age was 59.9 years. Clinical outcome was evaluated based on interoperative complications, the Japanese Orthopaedic Association score (JOA score), and cuff integrity using MRI Sugaya's classification. In the over 75 patients, anchors came out from the tuberosity in three patients. Postoperative complications were not seen in both groups. No differences were observed in JOA score and cuff integrity using MRI Sugaya's classification compared with patients under 75. The surgical outcome of ARCR for elderly people (over 75-years) was satisfactory, and ARCR for elderly people (over 75-years) shoud be performed with caution because of the coming out of anchors. (author)

  1. PRP as an Adjunct to Rotator Cuff Tendon Repair.

    Science.gov (United States)

    Barber, F Alan

    2018-06-01

    Arthroscopic rotator cuff repair is a commonly performed repair. Technical developments provide surgeons the tools to create biomechanically robust repairs. How can the biological response mirror the strong and stable surgery? Platelet-rich plasma (PRP) is a supraphysiological platelet concentration which may positively augment rotator cuff healing. Not all PRPs are the same. High leukocyte levels and thrombin activation may be detrimental to tendon healing. Thrombin activation triggers an immediate release of growth factors and may actually inhibit some parts of the healing response. Clear differences exist between liquid PRP (products released within hours after activation) and solid fibrin PRP which slowly releases factors over days. The heterogenicity data and grouping liquid and solid PRP together make systematic reviews confusing. Solid PRP fibrin constructs are often associated with increased tendon healing. PRP fibrin matrix offers the greatest promise for improving clinical success after rotator cuff tendon repair.

  2. Cochlear implant electrode localization in post-operative CT using a spherical measure

    DEFF Research Database (Denmark)

    Braithwaite, Benjamin Michael; Kjer, Hans Martin; Fagertun, Jens

    2016-01-01

    the ordering of electrode contacts on implanted electrode arrays from post-operative CT images. Our method applies a specialized filter chain to the images based on a threshold and spherical measure, and selects contact positions at local maxima in the filtered image. Two datasets of 13 temporal bone specimens...

  3. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  4. Advances in biologic augmentation for rotator cuff repair

    Science.gov (United States)

    Patel, Sahishnu; Gualtieri, Anthony P.; Lu, Helen H.; Levine, William N.

    2016-01-01

    Rotator cuff tear is a very common shoulder injury that often necessitates surgical intervention for repair. Despite advances in surgical techniques for rotator cuff repair, there is a high incidence of failure after surgery because of poor healing capacity attributed to many factors. The complexity of tendon-to-bone integration inherently presents a challenge for repair because of a large biomechanical mismatch between the tendon and bone and insufficient regeneration of native tissue, leading to the formation of fibrovascular scar tissue. Therefore, various biological augmentation approaches have been investigated to improve rotator cuff repair healing. This review highlights recent advances in three fundamental approaches for biological augmentation for functional and integrative tendon–bone repair. First, the exploration, application, and delivery of growth factors to improve regeneration of native tissue is discussed. Second, applications of stem cell and other cell-based therapies to replenish damaged tissue for better healing is covered. Finally, this review will highlight the development and applications of compatible biomaterials to both better recapitulate the tendon–bone interface and improve delivery of biological factors for enhanced integrative repair. PMID:27750374

  5. Effect of 3 months of progressive high-load strength training in patients with rotator cuff tendinopathy: Primary results from the double-blind, randomised, controlled Rotator Cuff Tendinopathy Exercise (RoCTEx) trial

    DEFF Research Database (Denmark)

    Ingwersen, Kim Gordon; Jensen, Steen Lund; Sørensen, Lilli

    2017-01-01

    BACKGROUND: Progressive high-load exercise (PHLE) has led to positive clinical results in patients with patellar and Achilles tendinopathy. However, its effects on rotator cuff tendinopathy still need to be investigated. PURPOSE: To assess the clinical effects of PHLE versus low-load exercise (LLE......) among patients with rotator cuff tendinopathy. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: Patients with rotator cuff tendinopathy were recruited and randomized to 12 weeks of PHLE or LLE, stratified for concomitant administration of corticosteroid injection. The primary...... benefit from PHLE over traditional LLE among patients with rotator cuff tendinopathy. Further investigation of the possible interaction between exercise type and corticosteroid injection is needed to establish optimal and potentially synergistic combinations of these 2 factors. REGISTRATION: NCT01984203...

  6. Phenomenological theory of current-producing processes at the solid oxide electrolyte/gas electrode interface: steady-state polarization of fuel-cell electrodes

    International Nuclear Information System (INIS)

    Murygin, I.V.; Chebotin, V.N.

    1979-01-01

    The polarization of fuel-cell electrodes (mixtures CO + CO 2 and H 2 + H 2 O) in systems with solid oxide electrolytes is discussed. The theory is based upon a process model where the electrode reaction zone can spread along the line of three-phase contact by diffusion of reaction partners and products across the electrolyte/electrode and electrolyte/gas interface

  7. Vaginal Cuff Dehiscence with Small Bowel Evisceration 14 Months after Total Abdominal Hysterectomy

    Directory of Open Access Journals (Sweden)

    Nida Jareemit, M.D.

    2017-11-01

    Full Text Available Introduction: Vaginal cuff dehiscence is a rare complication following hysterectomy. The condition coexisting with intraabdominal organ evisceration occurs even rarer. Nevertheless this should not be neglected owing to high morbidity and mortality. Case presentation: The reported case is a 48-year-old widow presenting with vaginal cuff dehiscence and small bowel evisceration after undergoing a total abdominal hysterectomy (TAH in the past 14 months due to myoma uteri. She denied having a history of sexual intercourse after the operation. The exposed bowel, 60 cm in length, appeared viable and no peritoneal sign was observed. There was a vaginal cuff defect approximately 3 cm in length. An exploratory laparotomy was then carried out. Eviscerated bowel was reduced back in the abdominal cavity and the vaginal cuff defect was repaired. No complications such as recurrent dehiscence were observed during one year follow-up. Conclusion: To minimize the incidence of vaginal cuff dehiscence after hysterectomy, surgical techniques should be of concern. Patient instructions, including delaying sexual intercourse and avoiding all possible causes of increased intra-abdominal pressure should be provided postoperatively.

  8. The effect of a rotator cuff tear and its size on three-dimensional shoulder motion.

    Science.gov (United States)

    Kolk, Arjen; Henseler, Jan Ferdinand; de Witte, Pieter Bas; van Zwet, Erik W; van der Zwaal, Peer; Visser, Cornelis P J; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H

    2017-06-01

    Rotator cuff-disease is associated with changes in kinematics, but the effect of a rotator cuff-tear and its size on shoulder kinematics is still unknown in-vivo. In this cross-sectional study, glenohumeral and scapulothoracic kinematics of the affected shoulder were evaluated using electromagnetic motion analysis in 109 patients with 1) subacromial pain syndrome (n=34), 2) an isolated supraspinatus tear (n=21), and 3) a massive rotator cuff tear involving the supraspinatus and infraspinatus (n=54). Mixed models were applied for the comparisons of shoulder kinematics between the three groups during abduction and forward flexion. In the massive rotator cuff-tear group, we found reduced glenohumeral elevation compared to the subacromial pain syndrome (16°, 95% CI [10.5, 21.2], protator cuff tears coincides with an increase in scapulothoracic lateral rotation compared to subacromial pain syndrome (11°, 95% CI [6.5, 15.2], protator cuff-tear group had substantially less glenohumeral elevation and more scapulothoracic lateral rotation compared to the other groups. These observations suggest that the infraspinatus is essential to preserve glenohumeral elevation in the presence of a supraspinatus tear. Shoulder kinematics are associated with rotator cuff-tear size and may have diagnostic potential. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Rotator cuff tear reduces muscle fiber specific force production and induces macrophage accumulation and autophagy.

    Science.gov (United States)

    Gumucio, Jonathan P; Davis, Max E; Bradley, Joshua R; Stafford, Patrick L; Schiffman, Corey J; Lynch, Evan B; Claflin, Dennis R; Bedi, Asheesh; Mendias, Christopher L

    2012-12-01

    Full-thickness tears to the rotator cuff can cause severe pain and disability. Untreated tears progress in size and are associated with muscle atrophy and an infiltration of fat to the area, a condition known as "fatty degeneration." To improve the treatment of rotator cuff tears, a greater understanding of the changes in the contractile properties of muscle fibers and the molecular regulation of fatty degeneration is essential. Using a rat model of rotator cuff injury, we measured the force generating capacity of individual muscle fibers and determined changes in muscle fiber type distribution that develop after a full thickness rotator cuff tear. We also measured the expression of mRNA and miRNA transcripts involved in muscle atrophy, lipid accumulation, and matrix synthesis. We hypothesized that a decrease in specific force of rotator cuff muscle fibers, an accumulation of type IIb fibers, and an upregulation in fibrogenic, adipogenic, and inflammatory gene expression occur in torn rotator cuff muscles. Thirty days following rotator cuff tear, we observed a reduction in muscle fiber force production, an induction of fibrogenic, adipogenic, and autophagocytic mRNA and miRNA molecules, and a dramatic accumulation of macrophages in areas of fat accumulation. Copyright © 2012 Orthopaedic Research Society.

  10. Muscle atrophy as a consequence of rotator cuff tears: should we compare the muscles of the rotator cuff with those of the deltoid?

    Energy Technology Data Exchange (ETDEWEB)

    Ashry, Reem; Schweitzer, Mark E.; Cunningham, Patricia; Cohen, Jodi; Babb, James; Cantos, Andrew [Hospital for Joint Diseases, NYU Medical Center, Department of Radiology, New York, NY (United States)

    2007-09-15

    The quantitative assessment of muscle atrophy has a degree of importance in prognosticating rotator cuff treatment. However, it has been conjectured that muscle fat increases with aging. Therefore, we thought that the quantitative assessment of the supraspinatous would be better if made in comparison with a standard of reference such as the deltoid. Consequently, we performed a two-part study, first evaluating supraspinatous changes compared with the deltoid in ''normals'' with aging, and second, determining if in patients with cuff tears the supraspinatous fat exceeds that of the deltoid. In part 1, we studied 50 patients stratified by decade. In the first sitting, two blinded independent observers quantitatively graded the deltoid (with the supraspinatous obscured) and in the second sitting the same two observers quantitatively graded the supraspinatous (with the deltoid obscured). In part 2 of the study, we evaluated patients with moderate rotator cuff tears (>2 cm) and performed the same blinded, two-sitting, quantitative assessment (with the comparison muscle obscured). We found that muscle atrophy increases with age in patients without tears (0.011/0.028 U/year), although to a greater degree in the deltoid (p = 0.032). Also, in similarly aged patients, quantitative scores of the deltoid closely matched those of the supraspinatous (p = 0.071). Notably, however, in patients with large tears, the supraspinatous showed significant changes disproportionate to those of the deltoid, regardless of patient age (p = 0.044). In the presence of a normal rotator cuff, fatty infiltration increases with age. Age-related changes occur more frequently in the deltoid, verifying this muscle's potential as a standard of reference. With cuff tears, supraspinatous atrophy was disproportionate to that of the deltoid. Therefore, systematic assessment of supraspinatous muscle atrophy may be more reliable using the deltoid as a control for comparison than

  11. Muscle atrophy as a consequence of rotator cuff tears: should we compare the muscles of the rotator cuff with those of the deltoid?

    International Nuclear Information System (INIS)

    Ashry, Reem; Schweitzer, Mark E.; Cunningham, Patricia; Cohen, Jodi; Babb, James; Cantos, Andrew

    2007-01-01

    The quantitative assessment of muscle atrophy has a degree of importance in prognosticating rotator cuff treatment. However, it has been conjectured that muscle fat increases with aging. Therefore, we thought that the quantitative assessment of the supraspinatous would be better if made in comparison with a standard of reference such as the deltoid. Consequently, we performed a two-part study, first evaluating supraspinatous changes compared with the deltoid in ''normals'' with aging, and second, determining if in patients with cuff tears the supraspinatous fat exceeds that of the deltoid. In part 1, we studied 50 patients stratified by decade. In the first sitting, two blinded independent observers quantitatively graded the deltoid (with the supraspinatous obscured) and in the second sitting the same two observers quantitatively graded the supraspinatous (with the deltoid obscured). In part 2 of the study, we evaluated patients with moderate rotator cuff tears (>2 cm) and performed the same blinded, two-sitting, quantitative assessment (with the comparison muscle obscured). We found that muscle atrophy increases with age in patients without tears (0.011/0.028 U/year), although to a greater degree in the deltoid (p 0.032). Also, in similarly aged patients, quantitative scores of the deltoid closely matched those of the supraspinatous (p = 0.071). Notably, however, in patients with large tears, the supraspinatous showed significant changes disproportionate to those of the deltoid, regardless of patient age (p = 0.044). In the presence of a normal rotator cuff, fatty infiltration increases with age. Age-related changes occur more frequently in the deltoid, verifying this muscle's potential as a standard of reference. With cuff tears, supraspinatous atrophy was disproportionate to that of the deltoid. Therefore, systematic assessment of supraspinatous muscle atrophy may be more reliable using the deltoid as a control for comparison than assessing it in isolation

  12. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    Science.gov (United States)

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731

  13. Resistance switching in silver - manganite contacts

    International Nuclear Information System (INIS)

    Gomez-Marlasca, F; Levy, P

    2009-01-01

    We investigate the electric pulse induced resistance switching in a transition metal oxide-metal contact at room temperature - a non volatile, reversible and multilevel memory device. Using a simple multiterminal configuration, we find that the complementary effect -in which the contact resistance of each pulsed electrode displays variations of opposite sign- is strongly influenced by the history of the pulsing procedure. Loops performed by varying the magnitude and sign of the stimulus at each pulsed electrode allow to disentangle their sole contribution at different stages of the process. Electromigration of oxygen ions and vacancies is discussed as participating at the core of the underlying mechanisms for resistance switching.

  14. Resistance switching in silver - manganite contacts

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Marlasca, F [Materia Condensada GIA GAIANN CAC -CNEA, and Instituto de Nanociencia y Nanotecnologia, CNEA, Gral Paz 1499 (1650) San Martin, Pcia. Buenos Aires (Argentina); Levy, P, E-mail: levy@cnea.gov.a

    2009-05-01

    We investigate the electric pulse induced resistance switching in a transition metal oxide-metal contact at room temperature - a non volatile, reversible and multilevel memory device. Using a simple multiterminal configuration, we find that the complementary effect -in which the contact resistance of each pulsed electrode displays variations of opposite sign- is strongly influenced by the history of the pulsing procedure. Loops performed by varying the magnitude and sign of the stimulus at each pulsed electrode allow to disentangle their sole contribution at different stages of the process. Electromigration of oxygen ions and vacancies is discussed as participating at the core of the underlying mechanisms for resistance switching.

  15. Genetic and familial predisposition to rotator cuff disease: a systematic review.

    Science.gov (United States)

    Dabija, Dominique I; Gao, Chan; Edwards, Todd L; Kuhn, John E; Jain, Nitin B

    2017-06-01

    Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and is likely to extend beyond repetitive microtrauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. A literature search of PubMed and Embase databases identified 251 citations. After review of the titles, abstracts, and full articles, 7 met our inclusion and exclusion criteria. Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A 5-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears did. The other 3 studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGF3, ESRRB, and FGF10 and 2 single-nucleotide polymorphisms within SAP30BP and SASH1. Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Diagnosis of subscapularis lesion in rotator cuff tears

    International Nuclear Information System (INIS)

    Terrier, F.; Wegmueller, H.; Vock, P.; Gerber, C.

    1989-01-01

    In rotator cuff tears, the subscapularis tendon is more often involved than previously suspected, and this lesion is often missed at arthrography. Because preoperative diagnosis is important for planning surgical repair, the authors have evaluated MR imaging and US in the detection of subscapularis tears. Fifteen patients with clinically suspected rotator cuff tears underwent MR imaging and US. Ten of 15 patients were treated surgically, and the other five were treated conservatively. MR imaging was performed with a 1.5-T Signa MR system. T1-weighted spin-echo (SE) and T2-weighted gradient-echo (GE) images were obtained

  17. Recent progress in multi-electrode spike sorting methods.

    Science.gov (United States)

    Lefebvre, Baptiste; Yger, Pierre; Marre, Olivier

    2016-11-01

    In recent years, arrays of extracellular electrodes have been developed and manufactured to record simultaneously from hundreds of electrodes packed with a high density. These recordings should allow neuroscientists to reconstruct the individual activity of the neurons spiking in the vicinity of these electrodes, with the help of signal processing algorithms. Algorithms need to solve a source separation problem, also known as spike sorting. However, these new devices challenge the classical way to do spike sorting. Here we review different methods that have been developed to sort spikes from these large-scale recordings. We describe the common properties of these algorithms, as well as their main differences. Finally, we outline the issues that remain to be solved by future spike sorting algorithms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Living with a symptomatic rotator cuff tear 'bad days, bad nights': a qualitative study.

    Science.gov (United States)

    Minns Lowe, Catherine J; Moser, Jane; Barker, Karen

    2014-07-09

    Rotator cuff tears are a common cause of shoulder pain. There is an absence of information about symptomatic rotator cuffs from the patients' perspective; this limits the information clinicians can share with patients and the information that patients can access via sources such as the internet. This study describes the experiences of people with a symptomatic rotator cuff, their symptoms, the impact upon their daily lives and the coping strategies utilised by study participants. An interpretive phenomenological analysis approach was used. 20 participants of the UKUFF trial (The United Kingdom Rotator Cuff Surgery Trial) agreed to participate in in-depth semi-structured interviews about their experiences about living with a symptomatic rotator cuff tear. Interviews were digitally recorded and fully transcribed. Field notes, memos and a reflexive diary were used. Data was coded in accordance with interpretive phenomenological analysis. Peer review, code-recode audits and constant comparison of data, codes and categories occurred throughout. The majority of patients described intense pain and severely disturbed sleep. Limited movement and reduced muscle strength were described by some participants. The predominantly adverse impact that a symptomatic rotator cuff tear had upon activities of daily living, leisure activities and occupation was described. The emotional and financial impact and impact upon caring roles were detailed. Coping strategies included attempting to carry on as normally as possible, accepting their condition, using their other arm, using analgesics, aids and adaptions. Clinicians need to appreciate and understand the intensity and shocking nature of pain that may be experienced by participants with known rotator cuff tears and understand the detrimental impact tears can have upon all areas of patient's lives. Clinicians also need to be aware of the potential emotional impact caused by cuff tears and to ensure that patients needing help for

  19. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    Science.gov (United States)

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  20. No difference in outcome for open versus arthroscopic rotator cuff repair: a prospective comparative trial.

    Science.gov (United States)

    Bayle, Xavier; Pham, Thuy-Trang; Faruch, Marie; Gobet, Aurelie; Mansat, Pierre; Bonnevialle, Nicolas

    2017-12-01

    Arthroscopic techniques tend to become the gold standard in rotator cuff repair. However, little data are reported in the literature regarding the improvement of postoperative outcomes and re-tear rate relative to conventional open surgery. The aim of this study was to compare clinical outcomes and cuff integrity after arthroscopic versus open cuff repair. We prospectively assessed clinical outcomes and cuff integrity after an arthroscopic or open rotator cuff repair with a minimum follow-up of 12 months. Clinical evaluation was based on Constant score, Simple Shoulder Value (SSV) and American Shoulder and Elbow Score (ASES). Rotator cuff healing was explored with ultrasound. 44 patients in arthroscopic group A (mean age 56-year-old) and 43 in open group O (mean age 61-year-old) fulfilled the inclusion criteria. Tendons were repaired with a single row technique associated with biceps tenodesis and subacromial decompression. All objective clinical scores significantly improved postoperatively in both groups. No statistical difference was identified between group A and O regarding, respectively, Constant score (72 vs 75 points; p = 0.3), ASES score (88 vs 91 points; p = 0.3), and SSV (81 vs 85%). The overall rate of re-tear (Sugaya type IV or V) reached 7 and 9%, respectively, in group A and O (p = 0.8). This study did not prove any difference of arthroscopic over open surgery in case of rotator cuff repair regarding clinical outcome and cuff integrity at 1-year follow-up. Prospective comparative study.

  1. Automated Control of Endotracheal Tube Cuff Pressure during Simulated Flight

    Science.gov (United States)

    2016-06-21

    accomplished in the intensive care unit (ICU) with stand-alone devices as well as those integral to a ventilator [13,14]. We hypothesized that closed loop ... Administration approved automatic cuff pressure adjustment devices (Intellicuff, Hamilton Medical , Reno, NV; Pyton, ARM Medical , Bristol, CT; Cuff Sentry, Outcome...711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Int’l Expeditionary Educ & Training Dept Air Force Expeditionary Medical

  2. Symptoms of Pain Do Not Correlate with Rotator Cuff Tear Severity

    Science.gov (United States)

    Dunn, Warren R.; Kuhn, John E.; Sanders, Rosemary; An, Qi; Baumgarten, Keith M.; Bishop, Julie Y.; Brophy, Robert H.; Carey, James L.; Holloway, G. Brian; Jones, Grant L.; Ma, C. Benjamin; Marx, Robert G.; McCarty, Eric C.; Poddar, Sourav K.; Smith, Matthew V.; Spencer, Edwin E.; Vidal, Armando F.; Wolf, Brian R.; Wright, Rick W.

    2014-01-01

    Background: For many orthopaedic disorders, symptoms correlate with disease severity. The objective of this study was to determine if pain level is related to the severity of rotator cuff disorders. Methods: A cohort of 393 subjects with an atraumatic symptomatic full-thickness rotator-cuff tear treated with physical therapy was studied. Baseline pretreatment data were used to examine the relationship between the severity of rotator cuff disease and pain. Disease severity was determined by evaluating tear size, retraction, superior humeral head migration, and rotator cuff muscle atrophy. Pain was measured on the 10-point visual analog scale (VAS) in the patient-reported American Shoulder and Elbow Surgeons (ASES) score. A linear multiple regression model was constructed with use of the continuous VAS score as the dependent variable and measures of rotator cuff tear severity and other nonanatomic patient factors as the independent variables. Forty-eight percent of the patients were female, and the median age was sixty-one years. The dominant shoulder was involved in 69% of the patients. The duration of symptoms was less than one month for 8% of the patients, one to three months for 22%, four to six months for 20%, seven to twelve months for 15%, and more than a year for 36%. The tear involved only the supraspinatus in 72% of the patients; the supraspinatus and infraspinatus, with or without the teres minor, in 21%; and only the subscapularis in 7%. Humeral head migration was noted in 16%. Tendon retraction was minimal in 48%, midhumeral in 34%, glenohumeral in 13%, and to the glenoid in 5%. The median baseline VAS pain score was 4.4. Results: Multivariable modeling, controlling for other baseline factors, identified increased comorbidities (p = 0.002), lower education level (p = 0.004), and race (p = 0.041) as the only significant factors associated with pain on presentation. No measure of rotator cuff tear severity correlated with pain (p > 0.25). Conclusions

  3. Wireless desalination using inductively powered porous carbon electrodes

    NARCIS (Netherlands)

    Kuipers, J.; Porada, S.

    2013-01-01

    Water desalination by capacitive deionization (CDI) uses electrochemical cell pairs formed of porous carbon electrodes, which are brought in contact with the water that must be desalinated. Upon applying a cell voltage or current between the electrodes, ions are electrosorbed and water is produced

  4. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    Science.gov (United States)

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score

  5. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair

    OpenAIRE

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-01-01

    Context: Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. Objective: To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Data Sources: Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. Study Sele...

  6. A Study on Graphene—Metal Contact

    Directory of Open Access Journals (Sweden)

    Hongyu Yu

    2013-03-01

    Full Text Available The contact resistance between graphene and metal electrodes is crucial for the achievement of high-performance graphene devices. In this study, we review our recent study on the graphene–metal contact characteristics from the following viewpoints: (1 metal preparation method; (2 asymmetric conductance; (3 annealing effect; (4 interfaces impact.

  7. Tracheomegaly Secondary to Tracheotomy Tube Cuff in Amyotrophic Lateral Sclerosis: A Case Report.

    Science.gov (United States)

    Lee, Dong Hoon; Yoon, Tae Mi; Lee, Joon Kyoo; Lim, Sang Chul

    2015-10-01

    Tracheomegaly has not been reported in amyotrophic lateral sclerosis (ALS). Herein, the authors report a case of tracheomegaly secondary to tracheotomy tube cuff in a patient with ALS. To our knowledge, this is the first report of an ALS patient with tracheomegaly and of tracheomegaly being associated with tracheotomy tube cuff and home tracheotomy mechanical ventilator.The clinician should consider the possibility of tracheomegaly in the differential diagnosis, if a patient with ALS develops repeat air leakage around the tracheotomy tube or rupture of tracheotomy tube cuff.

  8. Surface modification of recording electrodes

    Directory of Open Access Journals (Sweden)

    Iaci Miranda Pereira

    2013-01-01

    Full Text Available Waterborne Polyurethanes (PUs are a family of polymers that contains urethane linkages synthesized in an aqueous environment and are thus free of organic solvents. Recently, waterborne PUs have been extensively studied for biomedical applications because of their biocompatibility. The present work investigates the following: (1 the impact on electrical performance of electrode materials (platinum and silicon modified chemically by a layer of waterborne PU, and (2 the behavior of rat cardiac fibroblasts and rat cardiomyocytes when in contact with an electrode surface. Diisocyanate and poly(caprolactone diol were the main reagents for producing PUs. The electrochemical impedance of the electrode/electrolyte interface was accessed by electrochemical impedance spectroscopy. The cellular viability, proliferation, and morphology changes were investigated using an MTT assay. Cardiomyocyte adherence was observed by scanning electron microscopy. The obtained surface was uniform, flat, and transparent. The film showed good adhesion, and no peeling was detected. The electrochemical impedance decreased over time and was influenced by the ionic permeability of the PU layer. The five samples did not show cytotoxicity when in contact with neonatal rat cells.

  9. A Multi-Parametric Device with Innovative Solid Electrodes for Long-Term Monitoring of pH, Redox-Potential and Conductivity in a Nuclear Waste Repository

    Directory of Open Access Journals (Sweden)

    Jordan Daoudi

    2017-06-01

    Full Text Available We present an innovative electrochemical probe for the monitoring of pH, redox potential and conductivity in near-field rocks of deep geological radioactive waste repositories. The probe is composed of a monocrystalline antimony electrode for pH sensing, four AgCl/Ag-based reference or Cl− selective electrodes, one Ag2S/Ag-based reference or S2− selective electrode, as well as four platinum electrodes, a gold electrode and a glassy-carbon electrode for redox potential measurements. Galvanostatic electrochemistry impedance spectroscopy using AgCl/Ag-based and platinum electrodes measure conductivity. The use of such a multi-parameter probe provides redundant information, based as it is on the simultaneous behaviour under identical conditions of different electrodes of the same material, as well as on that of electrodes made of different materials. This identifies the changes in physical and chemical parameters in a solution, as well as the redox reactions controlling the measured potential, both in the solution and/or at the electrode/solution interface. Understanding the electrochemical behaviour of selected materials thus is a key point of our research, as provides the basis for constructing the abacuses needed for developing robust and reliable field sensors.

  10. Diagnosis of the rotator cuff rupture by computed tomography

    International Nuclear Information System (INIS)

    Yoh, Sansen; Takagishi, Naoto; Hirusaki, Takao; Hara, Masafumi; Nakamura, Kazuteru

    1983-01-01

    Twenty rotator cuff ruptures were diagnosed by CT. Plain CT was unable to reveal the damage, and CT arthrography was needed. CT arthrography was performed with a 3.25% low-concentration contrast medium to fill the shoulder joint by keeping the joint at the position of the maximal external rotation. CT identified the rotator cuff rupture more easily than other methods and disclosed the degree of the damage. CT may be useful in diagnosing the pathological state in various diseases of the shoulder joint.(Ueda, J.)

  11. Muscle Progenitor Cell Regenerative Capacity in the Torn Rotator Cuff

    Science.gov (United States)

    Meyer, Gretchen A.; Farris, Ashley L.; Sato, Eugene; Gibbons, Michael; Lane, John G.; Ward, Samuel R.; Engler, Adam J.

    2014-01-01

    Chronic rotator cuff (RC) tears affect a large portion of the population and result in substantial upper extremity impairment, shoulder weakness, pain and limited range of motion. Regardless of surgical or conservative treatment, persistent atrophic muscle changes limit functional restoration and may contribute to surgical failure. We hypothesized that deficits in the skeletal muscle progenitor (SMP) cell pool could contribute to poor muscle recovery following tendon repair. Biopsies were obtained from patients undergoing arthroscopic RC surgery. The SMP population was quantified, isolated and assayed in culture for its ability to proliferate and fuse in-vitro and in-vivo. The SMP population was larger in muscles from cuffs with partial tears compared with no tears or full thickness tears. However, SMPs from muscles in the partial tear group also exhibited reduced proliferative ability. Cells from all cuff states were able to fuse robustly in culture and engraft when injected into injured mouse muscle, suggesting that when given the correct signals, SMPs are capable of contributing to muscle hypertrophy and regeneration regardless of tear severity. The fact that this does not appear to happen in-vivo helps focus future therapeutic targets for promoting muscle recovery following rotator cuff repairs and may help improve clinical outcomes. PMID:25410765

  12. Deactivation of nickel hydroxide-gold modified electrodes

    OpenAIRE

    Caram, Bruno; Tucceri, Ricardo

    2013-01-01

    The aim of the present work was to study how the charge-transport process of a nickel hydroxide film electrochemically synthesized on a gold substrate is modified when the electrode is stored for a long time. It was found that nickel hydroxide films are deactivated under storage, that is, films became less conductive than films immediately prepared (nondeactivated). This study was carried out in the context of the rotating disc electrode voltammetry when the modified electrode contacts an ele...

  13. MEASUREMENT OF ENDOTRACHEAL TUBE CUFF PRESSURE IN MECHANICALLYVENTILATED PATIENTS ON ARRIVAL TO INTENSIVE CARE UNIT - A CROSS-SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Arun Kumar Ajjappa

    2017-04-01

    Full Text Available BACKGROUND The monitoring of Endotracheal Tube (ETT cuff pressure in intubated patients on arrival to intensive care unit is very essential. The cuff pressure must be within an optimal range of 20-30cm H2O ensuring ventilation with no complications related to cuff overinflation and underinflation. This can be measured with a cuff pressure manometer. The aim of the study is to measure the endotracheal tube cuff pressure in patients on arrival to intensive care unit and to identify prevalence of endotracheal cuff underinflation and overinflation. MATERIALS AND METHODS A cross-sectional study was done on mechanically-ventilated patients who were intubated in casualty (emergency department on arrival to intensive care unit in S.S. Institute of Medical Sciences and Research Centre, Davangere. About 50 critically-ill patients intubated with a high volume, low pressure endotracheal tube were included in the study. An analogue manometer was used to measure the endotracheal tube cuff pressure. It was compared with the recommended level. The settings of mechanical ventilation, endotracheal tube size and peak airway pressure were recorded. RESULTS It was found that the mean cuff pressure was 64.10 cm of H2O with a standard deviation of 32.049. Of the measured cuff pressures, only 2% had pressures within an optimal range (20-30cm of H2O. 88% had cuff pressures more than 30cm of H2O. The mean peak airway pressure found to be 20.50cm of H2O with a Standard Deviation (SD of 5.064. CONCLUSION This study is done to emphasise the importance of cuff pressure measurement in all mechanically-ventilated patients as cuff pressure is found to be high in most of the patients admitted to intensive care unit. Complications of overinflation and underinflation can only be prevented if the acceptable cuff pressures are achieved.

  14. Cuff deflation: rehabilitation in critical care.

    Science.gov (United States)

    Bach, John R; Gonçalves, Miguel R; Rodriguez, Pedro Landete; Saporito, Louis; Soares, Luisa

    2014-08-01

    This is a case series of rehabilitation failures that resulted in severe reactive depression from patients unnecessarily bereft of verbal communication by being left to breathe or be ventilated via tracheostomy tubes, with or without inflated cuffs, for months to years.

  15. The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.

    Science.gov (United States)

    Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A

    2012-08-01

    Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair becomes the more cost-effective surgical option. The identification of the threshold values in this study may help surgeons to determine the most cost-effective treatment.

  16. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.

    Science.gov (United States)

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-12-01

    Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.

  17. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  18. Cermet electrode

    Science.gov (United States)

    Maskalick, Nicholas J.

    1988-08-30

    Disclosed is a cermet electrode consisting of metal particles of nickel, cobalt, iron, or alloys or mixtures thereof immobilized by zirconia stabilized in cubic form which contains discrete deposits of about 0.1 to about 5% by weight of praseodymium, dysprosium, terbium, or a mixture thereof. The solid oxide electrode can be made by covering a substrate with particles of nickel, cobalt, iron, or mixtures thereof, growing a stabilized zirconia solid oxide skeleton around the particles thereby immobilizing them, contacting the skeleton with a compound of praseodymium, dysprosium, terbium, or a mixture thereof, and heating the skeleton to a temperature of at least 500.degree. C. The electrode can also be made by preparing a slurry of nickel, cobalt, iron, or mixture and a compound of praseodymium, dysprosium, terbium, or a mixture thereof, depositing the slurry on a substrate, heating the slurry to dryness, and growing a stabilized zirconia skeleton around the metal particles.

  19. Vitamin D and the immunomodulation of rotator cuff injury

    Directory of Open Access Journals (Sweden)

    Dougherty KA

    2016-06-01

    Full Text Available Kaitlin A Dougherty,1 Matthew F Dilisio,2 Devendra K Agrawal1 1Department of Clinical & Translational Science, 2Department of Orthopedic Surgery, Creighton University School of Medicine, Omaha, NE, USA Abstract: Tendon-to-bone healing after rotator cuff repair surgery has a failure rate of 20%–94%. There has been a recent interest to determine the factors that act as determinants between successful and unsuccessful rotator cuff repair. Vitamin D level in patients is one of the factors that have been linked to bone and muscle proliferation and healing, and it may have an effect on tendon-to-bone healing. The purpose of this article is to critically review relevant published research that relates to the effect of vitamin D on rotator cuff tears and subsequent healing. A review of the literature was conducted to identify all studies that investigate the relationship between vitamin D and tendon healing, in addition to its mechanism of action. The data were then analyzed in order to summarize what is currently known about vitamin D, rotator cuff pathology, and tendon-to-bone healing. The activated metabolite of vitamin D, 1α,25-dihydroxyvitamin D3, affects osteoblast proliferation and differentiation. Likewise, vitamin D plays a significant role in the tendon-to-bone healing process by increasing the bone mineral density and strengthening the skeletal muscles. The 1α,25-dihydroxyvitamin D3 binds to vitamin D receptors on myocytes to stimulate growth and proliferation. The form of vitamin D produced by the liver, calcifediol, is a key initiator of the myocyte healing process by moving phosphate into myocytes, which improves function and metabolism. Investigation into the effect of vitamin D on tendons has been sparse, but limited studies have been promising. Matrix metalloproteinases play an active role in remodeling the extracellular matrix (ECM of tendons, particularly deleterious remodeling of the collagen fibers. Also, the levels of

  20. Ultrasound of the rotator cuff with MRI and anatomic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Rutten, Matthieu J.C.M. [Department of Radiology, Jeroen Bosch Hospital, Nieuwstraat 34, 5211 NL ' s-Hertogenbosch (Netherlands)]. E-mail: M.Rutten@JBZ.nl; Maresch, Bas J. [Department of Radiology, Hospital Gelderse Vallei, Willy Brandtlaan 10, 6710 HN Ede (Netherlands)]. E-mail: MareschB@zgv.nl; Jager, Gerrit J. [Department of Radiology, Jeroen Bosch Hospital, Nieuwstraat 34, 5211 NL ' s-Hertogenbosch (Netherlands)]. E-mail: G.Jager@JBZ.nl; Blickman, Johan G. [Department of Radiology, University Medical Center Nijmegen, Geert Grooteplein Zuid 18, 6500 HB Nijmegen (Netherlands)]. E-mail: J.Blickman@rad.umcn.nl; Holsbeeck, Marnix T. van [Department of Radiology, Henry Ford Hospital, 2799 W Grand Boulevard, Detroit, MI 48202 (United States)]. E-mail: vanholsbeeck@comcast.net

    2007-06-15

    Magnetic resonance imaging and high-resolution ultrasound (US) are frequently used for the detection of rotator cuff tears. The diagnostic yield of US is influenced by several factors as technique, knowledge of the imaging characteristics of anatomic and pathologic findings and of pitfalls. The purpose of this article is to illustrates that the standardized high-resolution US examination of the shoulder covers the entire rotator cuff and correlates with MR imaging and anatomic sections.

  1. Tracheomegaly Secondary to Tracheotomy Tube Cuff in Amyotrophic Lateral Sclerosis

    OpenAIRE

    Lee, Dong Hoon; Yoon, Tae Mi; Lee, Joon Kyoo; Lim, Sang Chul

    2015-01-01

    Abstract Tracheomegaly has not been reported in amyotrophic lateral sclerosis (ALS). Herein, the authors report a case of tracheomegaly secondary to tracheotomy tube cuff in a patient with ALS. To our knowledge, this is the first report of an ALS patient with tracheomegaly and of tracheomegaly being associated with tracheotomy tube cuff and home tracheotomy mechanical ventilator. The clinician should consider the possibility of tracheomegaly in the differential diagnosis, if a patient with AL...

  2. Highly sensitive simultaneous electrochemical determination of trace amounts of Pb(II) and Cd(II) using a carbon paste electrode modified with multi-walled carbon nanotubes and a newly synthesized Schiff base

    International Nuclear Information System (INIS)

    Afkhami, Abbas; Ghaedi, Hamed; Madrakian, Tayyebeh; Rezaeivala, Majid

    2013-01-01

    Highlights: ► A new chemically modified carbon paste electrode was constructed and used. ► A new Schiff base and multi-walled carbon nanotube was used as modifiers. ► The electrochemical properties of the modified electrode were studied. ► The electrode was used to the simultaneous determination of Pb 2+ and Cd 2+ . -- Abstract: A new chemically modified electrode was constructed for rapid, simple, accurate, selective and highly sensitive simultaneous determination of lead and cadmium using square wave anodic stripping voltammetry (SWASV). The electrode was prepared by incorporation of new synthesized Schiff base and multi-walled carbon nanotubes (MWCNT) in carbon paste electrode. The limit of detection was found to be 0.25 ng mL −1 and 0.74 ng mL −1 for Pb 2+ and Cd 2+ , respectively. The stability constants of the complexes of the ligand with several metal cations in ethanol medium were determined. The effects of different cations and anions on the simultaneous determination of metal ions were studied and it was found that the electrode is highly selective. The proposed chemically modified electrode was used for the determination of lead and cadmium in several foodstuffs and water samples

  3. Glassy carbon electrode modified with multi-walled carbon nanotubes sensor for the quantification of antihistamine drug pheniramine in solubilized systems.

    Science.gov (United States)

    Jain, Rajeev; Sharma, Sanjay

    2012-02-01

    A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with multi-walled carbon nanotubes in the presence of sodium lauryl sulfate. The experimental results suggest that the pheniramine in anionic surfactant solution exhibits electrocatalytic effect resulting in a marked enhancement of the peak current response. Peak current response is linearly dependent on the concentration of pheniramine in the range 200-1500 μg/mL with correlation coefficient 0.9987. The limit of detection is 58.31 μg/mL. The modified electrode shows good sensitivity and repeatability.

  4. Incidence of retear with double-row versus single-row rotator cuff repair.

    Science.gov (United States)

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  5. Difference in vascular patterns between transosseous-equivalent and transosseous rotator cuff repair.

    Science.gov (United States)

    Urita, Atsushi; Funakoshi, Tadanao; Horie, Tatsunori; Nishida, Mutsumi; Iwasaki, Norimasa

    2017-01-01

    Vascularity is the important factor of biologic healing of the repaired tissue. The purpose of this study was to clarify sequential vascular patterns of repaired rotator cuff by suture techniques. We randomized 21 shoulders in 20 patients undergoing arthroscopic rotator cuff repair into 2 groups: transosseous-equivalent repair (TOE group, n = 10) and transosseous repair (TO group, n = 11). Blood flow in 4 regions inside the cuff (lateral articular, lateral bursal, medial articular, and medial bursal), in the knotless suture anchor in the TOE group, and in the bone tunnel in the TO group was measured using contrast-enhanced ultrasound at 1 month, 2 months, 3 months, and 6 months postoperatively. The sequential vascular pattern inside the repaired rotator cuff was different between groups. The blood flow in the lateral articular area at 1 month, 2 months, and 3 months (P = .002, .005, and .025) and that in the lateral bursal area at 2 months (P = .031) in the TO group were significantly greater than those in the TOE group postoperatively. Blood flow was significantly greater for the bone tunnels in the TO group than for the knotless suture anchor in the TOE group at 1 month and 2 months postoperatively (P = .041 and .009). This study clarified that the sequential vascular pattern inside the repaired rotator cuff depends on the suture technique used. Bone tunnels through the footprint may contribute to biologic healing by increasing blood flow in the repaired rotator cuff. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Mechanical Contact Experiments and Simulations

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Martins, P; Zhang, W.

    2011-01-01

    Mechanical contact is studied under dynamic development by means of a combined numerical and experimental investigation. The experiments are designed to allow dynamical development of non-planar contact areas with significant expansion in all three directions as the load is increased. Different....... The overall investigation serves for testing and validating the numerical implementation of the mechanical contact, which is one of the main contributions to a system intended for 3D simulation of resistance welding. Correct modelling of contact between parts to be welded, as well as contact with electrodes......, is crucial for satisfactory modelling of the resistance welding process. The resistance heating at the contact interfaces depends on both contact area and pressure, and as the contact areas develop dynamically, the presented tests are relevant for assessing the validity and accuracy of the mechanical contact...

  7. Lithium electrode and an electrical energy storage device containing the same

    Science.gov (United States)

    Lai, San-Cheng

    1976-07-13

    An improved lithium electrode structure comprises an alloy of lithium and silicon in specified proportions and a supporting current-collecting matrix in intimate contact with said alloy. The lithium electrode of the present invention is utilized as the negative electrode in a rechargeable electrochemical cell.

  8. Characterization of Deposited Platinum Contacts onto Discrete Graphene Flakes for Electrical Devices

    KAUST Repository

    Holguin Lerma, Jorge A.

    2016-05-03

    For years, electron beam induced deposition has been used to fabricate electrical contacts for micro and nanostructures. The role of the contact resistance is key to achieve high performance and efficiency in electrical devices. The present thesis reports on the electrical, structural and chemical characterization of electron beam deposited platinum electrodes that are exposed to different steps of thermal annealing and how they are used in four-probe devices of ultrathin graphite (uG) flakes (<100nm thickness). The device integration of liquid phase exfoliated uG is demonstrated, and its performance compared to devices made with analogous mechanically exfoliated uG. For both devices, similar contact resistances of ~2kΩ were obtained. The electrical measurements confirm a 99.5% reduction in contact resistance after vacuum thermal annealing at 300 °C. Parallel to this, Raman characterization confirms the formation of a nanocrystalline carbon structure over the electrode. While this could suggest an enhancement of the electrical transport in the device, an additional thermal annealing step in air at 300 °C, promoted the oxidation and removal of the carbon shell and confirmed that the contact resistance remained the same. Overall this shows that the carbon shell along the electrode has no significant role in the contact resistance. Finally, the challenges based on topographical analysis of the deposited electrodes are discussed. Reduction of the electrode’s height down to one-third of the initial value, increased surface roughness, formation of voids along the electrodes and the onset of platinum nanoparticles near the area of deposition, represent a challenge for future work.

  9. Multi electrode semiconductors detectors

    CERN Document Server

    Amendolia, S R; Bertolucci, Ennio; Bosisio, L; Bradaschia, C; Budinich, M; Fidecaro, F; Foà, L; Focardi, E; Giazotto, A; Giorgi, M A; Marrocchesi, P S; Menzione, A; Ristori, L; Rolandi, Luigi; Scribano, A; Stefanini, A; Vincelli, M L

    1981-01-01

    Detectors with very high space resolution have been built in this laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (3 refs).

  10. Multi electrode semiconductor detectors

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Batignani, G.; Bertolucci, E.; Bosisio, L.; Budinich, M.; Bradaschia, C.; Fidecaro, F.; Foa, L.; Focardi, E.; Giazotto, A.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Rolandi, L.; Scribano, A.; Stefanini, A.; Vincelli, M.L.

    1981-01-01

    Detectors with very high space resolution have been built in the laboratory and tested at CERN in order to investigate their possible use in high energy physics experiments. These detectors consist of thin layers of silicon crystals acting as ionization chambers. Thin electrodes, structured in strips or in more fancy shapes are applied to their surfaces by metal coating. The space resolution which could be reached is of the order of a few microns. An interesting feature of these solid state detectors is that they can work under very high or low external pressure or at very low temperature. The use of these detectors would strongly reduce the dimensions and the cost of high energy experiments. (Auth.)

  11. Partial rotator cuff repair and biceps tenotomy for the treatment of patients with massive cuff tears and retained overhead elevation: midterm outcomes with a minimum 5 years of follow-up.

    Science.gov (United States)

    Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G

    2016-11-01

    A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up. Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear. Patients had preoperative active forward elevation >120° and no radiographic evidence of glenohumeral arthritis. Patients were followed up clinically and radiographically, and 28 patients had a minimum of 5 years of follow-up. Failure was defined as an American Shoulder and Elbow Surgeons score of 90°, or revision to reverse shoulder arthroplasty during the study period. Patients demonstrated improvements in average preoperative to postoperative American Shoulder and Elbow Surgeons scores (46.6 to 79.3 [P rotation (38° to 39° [P = 1.0]), or internal rotation (84% to 80% [P = 1.0]) was identified; 36% of patients had progression of the Hamada stage. The failure rate was 29%; 75% of patients were satisfied with their index procedure. Partial rotator cuff repair and biceps tenotomy for patients with massive irreparable rotator cuff tears with retained overhead elevation and pain as the primary complaint produced reasonable outcomes at midterm follow-up of at least 5 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Effect of multi-layered bottom electrodes on the orientation of strontium-doped lead zirconate titanate thin films

    Energy Technology Data Exchange (ETDEWEB)

    Bhaskaran, M. [Microelectronics and Materials Technology Centre, School of Electrical and Computer Engineering, RMIT University, GPO Box 2476V, Melbourne, Victoria 3001 (Australia)], E-mail: madhu.bhaskaran@gmail.com; Sriram, S. [Microelectronics and Materials Technology Centre, School of Electrical and Computer Engineering, RMIT University, GPO Box 2476V, Melbourne, Victoria 3001 (Australia); Mitchell, D.R.G.; Short, K.T. [Institute of Materials Engineering, Australian Nuclear Science and Technology Organisation (ANSTO), PMB 1, Menai, New South Wales 2234 (Australia); Holland, A.S. [Microelectronics and Materials Technology Centre, School of Electrical and Computer Engineering, RMIT University, GPO Box 2476V, Melbourne, Victoria 3001 (Australia)

    2008-09-30

    This article discusses the results from X-ray diffraction (XRD) analysis of piezoelectric strontium-doped lead zirconate titanate (PSZT) thin films deposited on multi-layer coatings on silicon. The films were deposited by RF magnetron sputtering on a metal coated substrate. The aim was to exploit the pronounced piezoelectric effect that is theoretically expected normal to the substrate. This work highlighted the influence that the bottom electrode architecture exerts on the final crystalline orientation of the deposited thin films. A number of bottom electrode architectures were used, with the uppermost metal layer on which PSZT was deposited being gold or platinum. The XRD analysis revealed that the unit cell of the PSZT thin films deposited on gold and on platinum were deformed, relative to expected unit cell dimensions. Experimental results have been used to estimate the unit cell parameters. The XRD results were then indexed based on these unit cell parameters. The choice and the thickness of the intermediate adhesion layers influenced the relative intensity, and in some cases, the presence of perovskite peaks. In some cases, undesirable reactions between the bottom electrode layers were observed, and layer architectures to overcome these reactions are also discussed.

  13. Failed healing of rotator cuff repair correlates with altered collagenase and gelatinase in supraspinatus and subscapularis tendons.

    Science.gov (United States)

    Robertson, Catherine M; Chen, Christopher T; Shindle, Michael K; Cordasco, Frank A; Rodeo, Scott A; Warren, Russell F

    2012-09-01

    Despite improvements in arthroscopic rotator cuff repair technique and technology, a significant rate of failed tendon healing persists. Improving the biology of rotator cuff repairs may be an important focus to decrease this failure rate. The objective of this study was to determine the mRNA biomarkers and histological characteristics of repaired rotator cuffs that healed or developed persistent defects as determined by postoperative ultrasound. Increased synovial inflammation and tendon degeneration at the time of surgery are correlated with the failed healing of rotator cuff tendons. Case-control study; Level of evidence, 3. Biopsy specimens from the subscapularis tendon, supraspinatus tendon, glenohumeral synovium, and subacromial bursa of 35 patients undergoing arthroscopic rotator cuff repair were taken at the time of surgery. Expression of proinflammatory cytokines, tissue remodeling genes, and angiogenesis factors was evaluated by quantitative real-time polymerase chain reaction. Histological characteristics of the affected tissue were also assessed. Postoperative (>6 months) ultrasound was used to evaluate the healing of the rotator cuff. General linear modeling with selected mRNA biomarkers was used to predict rotator cuff healing. Thirty patients completed all analyses, of which 7 patients (23%) had failed healing of the rotator cuff. No differences in demographic data were found between the defect and healed groups. American Shoulder and Elbow Surgeons shoulder scores collected at baseline and follow-up showed improvement in both groups, but there was no significant difference between groups. Increased expression of matrix metalloproteinase 1 (MMP-1) and MMP-9 was found in the supraspinatus tendon in the defect group versus the healed group (P = .006 and .02, respectively). Similar upregulation of MMP-9 was also found in the subscapularis tendon of the defect group (P = .001), which was consistent with the loss of collagen organization as determined by

  14. Device for welding a connection line to an electrode of a solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Lorans, D.Y.

    1976-08-05

    A method with associated device for welding connection lines to the electrodes of solar cells is described. To improve the weldability of the contacts usually consisting of silver, a weld-receiving device is vibrated with respect to the welding electrode, whereby disturbing surface layers are destroyed with a certain application pressure of the welding electrode. The method shows better results than, for example, a previous chemical cleaning of the contacts and is also more easy to handle.

  15. Source/drain electrodes contact effect on the stability of bottom-contact pentacene field-effect transistors

    Directory of Open Access Journals (Sweden)

    Xinge Yu

    2012-06-01

    Full Text Available Bottom-contact pentacene field-effect transistors were fabricated with a PMMA dielectric layer, and the air stability of the transistors was investigated. To characterize the device stability, the field-effect transistors were exposed to ambient conditions for 30 days and subsequently characterized. The degradation of electrical performance was traced to study the variation of field-effect mobility, saturation current and off-state current. By investigating the morphology variance of the pentacene film at the channel and source/drain (S/D contact regions by atomic force microscopy, it was clear that the morphology of the pentacene film adhered to the S/D degenerated dramatically. Moreover, by studying the variation of contact resistance in detail, it was found that the S/D contact effect was the main reason for the degradation in performance.

  16. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    OpenAIRE

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-s...

  17. Design, simulation and fabrication of a novel contact-enhanced MEMS inertial switch with a movable contact point

    International Nuclear Information System (INIS)

    Cai Haogang; Ding Guifu; Yang Zhuoqing; Su Zhijuan; Zhou Jiansheng; Wang Hong

    2008-01-01

    A novel inertial switch based on a micro-electro-mechanical system (MEMS) was designed, which consists of three main parts: a proof mass as the movable electrode, a cross beam as the stationary electrode and a movable contact point to prolong the contact time. A MATLAB/Simulink model, which had been verified by comparison with ANSYS transient simulation, was built to simulate the dynamic response, based on which the contact-enhancing mechanism was confirmed and the dependence of threshold acceleration on the proof mass thickness was studied. The simulated dynamic responses under various accelerations exhibit satisfactory device behaviors: the switch-on time is prolonged under transient acceleration; the switch-on state is more continuous than the conventional design under long lasting acceleration. The inertial micro-switch was fabricated by multilayer electroplating technology and then tested by a drop hammer experiment. The test results indicate that the contact effect was improved significantly and a steady switch-on time of over 50 µs was observed under half-sine wave acceleration with 1 ms duration, in agreement with the dynamic simulation

  18. Comparative studies of MRI and operative findings in rotator cuff tear

    International Nuclear Information System (INIS)

    Yamakawa, Seigo; Ichikawa, Norikazu; Itadera, Eichi; Hashizume, Hiroyuki; Inoue, Hajime

    2001-01-01

    A prospective study was performed to determine the accuracy of magnetic resonance imaging (MRI) compared with operative findings in the evaluation of patients associated with rotator cuff tears. Fifty-four of 60 shoulders (58 patients) examined by MRI were confirmed as full-thickness tears and 6 as partial-thickness tears at the time of surgery. The oblique coronal, oblique sagittal, and axial planes of T2-weighted images with the 0.5 tesla MRI system were obtained preoperatively and compared with operative findings. MRI correctly identified 46 of 54 full-thickness rotator cuff tears and 5 of 6 partial-thickness tears. A comparison of MRI and operative findings in full-thickness cuff tears showed a sensitivity of 85%, a specificity of 83%, and a positive prospective value (PPV) of 99%. A comparison of partial-thickness tears showed a sensitivity of 83%, a specificity of 85%, and PPV of 39%. Linear regression analysis showed an excellent correlation between the MRI assessment and measurement at the time of surgery (r=0.90, P<0.01). MRI was useful in evaluating large and medium-sized rotator cuff tears, but less useful in distinguishing small full-thickness tears from partial-thickness tears. (author)

  19. Functional evaluation of patient after arthroscopic repair of rotator cuff tear.

    Science.gov (United States)

    Kumar, Rohit; Jadhav, Umesh

    2014-06-01

    Rotator cuff tear is a common problem either after trauma or after degenerative tear in old age group. Arthroscopic repair is the current concept of rotator cuff repair. Here, we are trying to evaluate the functional outcome after arthroscopic repair of full thickness rotator cuff tear (single row) in Indian population. Twenty five patients (14 males and 11 females) who underwent arthroscopic repair of full thickness rotator cuff tear at a single institution were included in the study. Postoperatively patient's shoulder was rated according to UCLA score, pain was graded according to the visual analog score. The range of motion was analysed and documented. The mean age of the patients were 50.48 years. The preoperative VAS score mode was 7 and post operative VAS was 1 (p value fair in 12% (n = 3), excellent in 8% (n = 2) and poor results were seen in none of the patients. The mean UCLA improved from a score of 15.84 to 30.28 with a p value advantages, hence we used a single row repair considering the Indian population and the cost effectiveness of the surgery with good to excellent results.

  20. Functional Outcomes and Predictors of Failure After Rotator Cuff Repair During Total Shoulder Arthroplasty.

    Science.gov (United States)

    Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena

    2018-05-01

    A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.

  1. Characterization of Deposited Platinum Contacts onto Discrete Graphene Flakes for Electrical Devices

    KAUST Repository

    Holguin Lerma, Jorge Alberto

    2016-01-01

    The electrical measurements confirm a 99.5% reduction in contact resistance after vacuum thermal annealing at 300 °C. Parallel to this, Raman characterization confirms the formation of a nanocrystalline carbon structure over the electrode. While this could suggest an enhancement of the electrical transport in the device, an additional thermal annealing step in air at 300 °C, promoted the oxidation and removal of the carbon shell and confirmed that the contact resistance remained the same. Overall this shows that the carbon shell along the electrode has no significant role in the contact resistance. Finally, the challenges based on topographical analysis of the deposited electrodes are discussed. Reduction of the electrode’s height down to one-third of the initial value, increased surface roughness, formation of voids along the electrodes and the onset of platinum nanoparticles near the area of deposition, represent a challenge for future work.

  2. Effects of age and pathology on shear wave speed of the human rotator cuff.

    Science.gov (United States)

    Baumer, Timothy G; Dischler, Jack; Davis, Leah; Labyed, Yassin; Siegal, Daniel S; van Holsbeeck, Marnix; Moutzouros, Vasilios; Bey, Michael J

    2018-01-01

    Rotator cuff tears are common and often repaired surgically, but post-operative repair tissue healing, and shoulder function can be unpredictable. Tear chronicity is believed to influence clinical outcomes, but conventional clinical approaches for assessing tear chronicity are subjective. Shear wave elastography (SWE) is a promising technique for assessing soft tissue via estimates of shear wave speed (SWS), but this technique has not been used extensively on the rotator cuff. Specifically, the effects of age and pathology on rotator cuff SWS are not well known. The objectives of this study were to assess the association between SWS and age in healthy, asymptomatic subjects, and to compare measures of SWS between patients with a rotator cuff tear and healthy, asymptomatic subjects. SWE images of the supraspinatus muscle and intramuscular tendon were acquired from 19 asymptomatic subjects and 11 patients with a rotator cuff tear. Images were acquired with the supraspinatus under passive and active (i.e., minimal activation) conditions. Mean SWS was positively associated with age in the supraspinatus muscle and tendon under passive and active conditions (p ≤ 0.049). Compared to asymptomatic subjects, patients had a lower mean SWS in their muscle and tendon under active conditions (p ≤ 0.024), but no differences were detected under passive conditions (p ≥ 0.783). These findings identify the influences of age and pathology on SWS in the rotator cuff. These preliminary findings are an important step toward evaluating the clinical utility of SWE for assessing rotator cuff pathology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:282-288, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Medialized repair for retracted rotator cuff tears.

    Science.gov (United States)

    Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun

    2017-08-01

    The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Outcome of Expedited Rotator Cuff Surgery in Injured Workers: Determinants of Successful Recovery.

    Science.gov (United States)

    Razmjou, Helen; Boljanovic, Dragana; Lincoln, Sandra; Holtby, Richard; Gallay, Stephen; Henry, Patrick; Macritchie, Iona; Borthwick, Cheryl; Mayer, Lauren; Roknic, Carolyn; Shore, Deborah; Kamino, Allison; Grossman, Julie; Hill, Joanne; Singh, Gargi; Travers, Niki; Yanofsky, Loraine; Wilson, Marni; Sumar, Shellina; Savona, Alicia; De Medeiros, Filomena; Mann, Helen; Champsi, Aisha; Chau, Stefanie; Medeiros, Danielle; Richards, Robin R

    2017-05-01

    Work-related rotator cuff injuries are a common cause of disability and employee time loss. To examine the effectiveness of expedited rotator cuff surgery in injured workers who underwent rotator cuff decompression or repair and to explore the impact of demographic, clinical, and psychosocial factors in predicting the outcome of surgery. Case series; Level of evidence, 4. Injured workers who were seen at a shoulder specialty program and who underwent expedited arthroscopic rotator cuff decompression or repair were observed for a period of 6 to 12 months based on their type of surgery and recovery trajectory. The primary outcome measure was the American Shoulder and Elbow Surgeons (ASES) Standardized Shoulder Assessment Form. The impact of surgery was assessed by whether the change in the ASES score exceeded the minimal clinically important difference (MCID) of 17 points. Secondary outcomes were range of motion (ROM), medication consumption, and work status. One hundred forty-six patients (43 women [29%], 103 men [71%]; mean age, 52 years; SD, 8 years) completed the study. Sixty-seven (46%) patients underwent rotator cuff repair. The mean time between the date the patient consented to have surgery and the date of surgery was 82 (SD, 44) days. There was a statistically significant improvement in ASES score and ROM and work status (52 returned to regular duties and 59 to modified duties) ( P satisfaction with the job. Expedited rotator cuff surgery improved disability, ROM, and work status in injured workers. Successful recovery after work-related shoulder injuries may further be facilitated by improving the psychosocial work environment and increasing access to care.

  5. A solvated electron lithium electrode for secondary batteries

    Science.gov (United States)

    Sammells, A. F.; Semkow, K. W.

    1986-09-01

    Attention is given to a novel method for the achievement of high electro-chemical reversibility in Li-based nonaqueous cells, using a liquid negative electrode that consists of Li dissolved in liquid ammonia as a solvated electron Li electrode. The containment of this liquid negative active material from direct contact to a liquid nonaqueous electrolyte in the positive electrode compartment was realized through the use of a Li-intercalated, electronically conducting ceramic membrane.

  6. Gout Can Increase the Risk of Receiving Rotator Cuff Tear Repair Surgery.

    Science.gov (United States)

    Huang, Shih-Wei; Wu, Chin-Wen; Lin, Li-Fong; Liou, Tsan-Hon; Lin, Hui-Wen

    2017-08-01

    Gout commonly involves joint inflammation, and clinical epidemiological studies on involved tendons are scant. Rotator cuff tears are the most common cause of shoulder disability, and surgery is one of the choices often adopted to regain previous function. To investigate the risk of receiving rotator cuff repair surgery among patients with gout and to analyze possible risk factors to design an effective prevention strategy. Cohort study; Level of evidence, 3. The authors studied a 7-year longitudinal follow-up of patients from the Taiwan Longitudinal Health Insurance Database 2005 (LHID2005). This included a cohort of patients who received a diagnosis of gout during 2004-2008 (gout cohort) and a cohort matched by propensity scores (control cohort). A 2-stage approach that used the National Health Interview Survey 2005 was used to obtain missing confounding variables from the LHID2005. The crude hazard ratio (HR) and adjusted HR were estimated between the gout and control cohorts. The gout and control cohorts comprised 32,723 patients with gout and 65,446 people matched at a ratio of 1:2. The incidence of rotator cuff repair was 31 and 18 per 100,000 person-years in the gout and control cohorts, respectively. The crude HR for rotator cuff repair in the gout cohort was 1.73 (95% confidence interval [CI], 1.23-2.44; P gout cohort. Further analysis revealed that the adjusted HR was 1.73 (95% CI, 1.20-2.50; P gout who did not take hypouricemic medication and 2.70 (95% CI, 1.31-5.59; P gout aged 50 years or younger. Patients with gout, particularly those aged 50 years or younger and without hypouricemic medication control, are at a relatively higher risk of receiving rotator cuff repair surgery. Strict control of uric acid levels with hypouricemic medication may effectively reduce the risk of rotator cuff repair.

  7. Comparison of self-report and interview administration methods based on the Brazilian versions of the Western Ontario Rotator Cuff Index and Disabilities of the Arm, Shoulder and Hand Questionnaire in patients with rotator cuff disorders

    Directory of Open Access Journals (Sweden)

    Andréa Diniz Lopes

    2009-02-01

    Full Text Available OBJECTIVE: The purpose of the present study was to compare self-report and interview administration methods using the Western Ontario Rotator Cuff Index (WORC and Disabilities of the Arm, Shoulder and Hand Questionnaire (DASH in patients with rotator cuff disorders. METHODS: Thirty male and female patients over 18 years of age with rotator cuff disorders (tendinopathy or rotator cuff tear and Brazilian Portuguese as their primary language were recruited for assessment via administration of the Western Ontario Rotator Cuff Index and and Disabilities of the Arm, Shoulder and Hand Questionnaire. A randomization method was used to determine whether the questionnaires would be self-reported (n=15 or administered by an interviewer (n=15. Pearson correlation coefficients were used to evaluate the correlation between the Western Ontario Rotator Cuff Index and and Disabilities of the Arm, Shoulder and Hand Questionnaire in each group. The t-test was used to determine whether the difference in mean questionnaire scores and administration time was statistically significant. For statistical analysis, the level of significance was set at 5%. RESULTS: The mean subject age was 55.07 years, ranging from 27 to 74 years. Most patients had a diagnosis of tendinopathy (n=21. With regard to level of schooling, the majority (n=26 of subjects had completed a college degree or higher. The mean questionnaire scores and administration times did not significantly differ between the two groups (p>0.05. There were statistically significant correlations (p<0.05 between Western Ontario Rotator Cuff Index and and Disabilities of the Arm, Shoulder and Hand Questionnaire, and strong correlations were found between the questionnaires in both groups. CONCLUSION: There are no differences between the Western Ontario Rotator Cuff Index and Disabilities of the Arm, Shoulder and Hand Questionnaire administration methods with regard to administration time or correlations between the

  8. Investigating interfacial contact configuration and behavior of single-walled carbon nanotube-based nanodevice with atomistic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Jianlei, E-mail: cjlxjtu@mail.xjtu.edu.cn; Zhang, Jianwei [Xi’an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering (China); He, Xiaoqiao, E-mail: bcxqhe@cityu.edu.hk [City University of Hong Kong, Department of Architecture and Civil Engineering (Hong Kong); Mei, Xuesong; Wang, Wenjun [Xi’an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering (China); Yang, Xinju [Fudan University, State Key Laboratory of Surface Physics and Department of Physics (China); Xie, Hui; Yang, Lijun; Wang, Yang [Harbin Institute of Technology, State Key Laboratory of Robotics and Systems (China)

    2017-03-15

    Carbon nanotubes (CNTs), including single-walled carbon nanotubes (SWNTs) and multi-walled carbon nanotubes (MWNTs), are considered to be the promising candidates for next-generation interconnects with excellent physical and chemical properties ranging from ultrahigh mechanical strength, to electrical properties, to thermal conductivity, to optical properties, etc. To further study the interfacial contact configurations of SWNT-based nanodevice with a 13.56-Å diameter, the corresponding simulations are carried out with the molecular dynamic method. The nanotube collapses dramatically into the surface with the complete collapse on the Au/Ag/graphite electrode surface and slight distortion on the Si/SiO{sub 2} substrate surface, respectively. The related dominant mechanism is studied and explained. Meanwhile, the interfacial contact configuration and behavior, depended on other factors, are also analyzed in this article.

  9. The relationship between age, rotator cuff integrity, and osseous microarchitecture of greater tuberosity: Where should we put anchor?

    Science.gov (United States)

    Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho

    2018-01-01

    The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects 50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.

  10. Is rotator cuff repair worthwhile in patients with co-morbidities?

    OpenAIRE

    Yash Kishore Shah; Rohan Kiran Khavte; Parag Kishore Munshi

    2015-01-01

    Background: Rotator cuff tears are a common source of shoulder pain. The incidence increases with age and is most frequently due to degeneration of the tendon, rather than injury. This study is done to see whether in patients having established rotator cuff tears with co-morbidities like hypertension diabetes, epilepsy, etc. a surgical repair is worthwhile or whether it is better to leave such patients alone in order to give them a better quality of life. Methods: A total of 35 patients w...

  11. The Burden of Craft in Arthroscopic Rotator Cuff Repair: Where Have We Been and Where We Are Going.

    Science.gov (United States)

    Burkhart, Stephen S

    2015-08-01

    The rather turbulent history of arthroscopic rotator cuff repair went through stages of innovation, conflict, disruption, assimilation, and transformation that might be anticipated when a new and advanced technology (arthroscopic cuff repair) displaces an entrenched but outdated discipline (open cuff repair). The transition from open to arthroscopic rotator cuff repair has been a major paradigm shift that has greatly benefited patients. However, this technical evolution/revolution has also imposed a higher "burden of craft" on the practitioners of arthroscopic rotator cuff repair. Technological advancements in surgery demand that surgeons accept this burden of craft and master the advanced technology for the benefit of their patients. This article outlines the author's involvement in the development of arthroscopic rotator cuff repair, and it also explores the surgeon's obligation to accept the burden of craft that is imposed by this discipline.

  12. Surgical Versus Nonsurgical Management of Rotator Cuff Tears: Predictors of Treatment Allocation.

    Science.gov (United States)

    Kweon, Christopher; Gagnier, Joel J; Robbins, Christopher B; Bedi, Asheesh; Carpenter, James E; Miller, Bruce S

    2015-10-01

    Rotator cuff tears are a common shoulder disorder resulting in significant disability to patients and financial burden on the health care system. While both surgical and nonsurgical management are accepted treatment options, there is a paucity of data to support a treatment algorithm for care providers. Defining variables to guide treatment allocation may be important for patient education and counseling, as well as to deliver the most efficient care plan at the time of presentation. To identify independent variables at the time of initial clinical presentation that are associated with preferred allocation to surgical versus nonsurgical management for patients with known full-thickness rotator cuff tears. Case control study; Level of evidence, 3. A total of 196 consecutive adult patients with known full-thickness rotator cuff tears were enrolled into a prospective cohort study. Robust data were collected for each subject at baseline, including age, sex, body mass index (BMI), shoulder activity score, smoking status, size of cuff tear, duration of symptoms, functional comorbidity index, the American Shoulder and Elbow Surgeons (ASES) score, the Western Ontario Rotator Cuff index (WORC), and the Veterans Rand 12-Item Health Survey (VR-12). Logistic regression was performed to identify variables associated with treatment allocation, and the corresponding odds ratios were calculated. Of the 196 patients enrolled, 112 underwent surgical intervention and 84 nonoperative management. With covariates controlled for, significant baseline patient characteristics predictive of eventual allocation to surgical treatment included younger age, lower BMI, and durations of symptoms less than 1 year. Increasing age, higher BMI, and duration of symptoms longer than 1 year were predictive of nonsurgical treatment. Factors that were not associated with treatment allocation included sex, tear size, functional comorbidity score, or any of the patient-derived outcome scores at presentation

  13. Alterations of the Deltoid Muscle After Open Versus Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Cho, Nam Su; Cha, Sang Won; Rhee, Yong Girl

    2015-12-01

    Open repair can be more useful than arthroscopic repair for immobile and severely retracted, large to massive rotator cuff tears. However, it is not known whether the deltoid muscle is altered after open repair or to what extent the deltoid origin remains detached after surgery. To compare postoperative alterations of the deltoid muscle in open versus arthroscopic repair for severely retracted, large to massive rotator cuff tears. Case-control study; Level of evidence, 3. Enrolled in this study were 135 patients who underwent surgical repair for severely retracted, large to massive rotator cuff tears and who had routine follow-up MRIs at least 6 months after surgery. Open repairs were performed in 56 cases and arthroscopic repairs in 79 cases. The detachment and thickness of the deltoid muscle at its proximal origin were recorded in 5 zones on MRI. The alterations of the deltoid muscle and postoperative integrity of the repaired rotator cuff were evaluated. Partial detachment of the deltoid occurred in 1 patient (1.8%) in the open group and in 2 patients (2.5%) in the arthroscopic group (P = .80). All the partial detachments occurred in zones 2 and 3. Attenuation of the proximal origin of the deltoid was found in 3 patients (5.4%) in the open group and in 4 patients (5.1%) in the arthroscopic group (P = .87). Atrophy of the deltoid muscle was shown in 3 patients (5.4%) in the open group and 4 patients (5.1%) in the arthroscopic group (P = .61). The retear rate of the repaired cuff was 30.4% (17/56) in the open group and 38.0% (30/79) in the arthroscopic group (P = .74). Between open and arthroscopic repair for severely retracted, large to massive rotator cuff tears, there was no significant difference in detachment of the deltoid origin and alterations of the deltoid muscle after repair. Postoperative alterations of the deltoid occurred in arthroscopic surgery as well as in open surgery. For immobile massive rotator cuff tear, open repair is an acceptable technique

  14. Studies of the source complex behaviour and of the ultrasound radiation of contact flexible multi-element transducers

    International Nuclear Information System (INIS)

    Amory, V.

    2007-12-01

    This work deals with the ultrasonic nondestructive testing of parts with complex geometries using soft multi-element sensors. The different types of contact control configurations are presented first. Then, the difficulties encountered with conventional contact transducers are explained and the multi-element piezoelectric transducers technology, developed to meet these difficulties, is presented. The second chapter presents the results of finite-element calculations showing the complexity of a transducer in a condition of testing utilization. In a same configuration, the radiated far field calculated by finite-elements is compared to the measurement in order to validate the way the source behaviour is calculated. However, despite the efficiency of the finite-elements simulation, this tool is numerically too costly and cannot be used to optimize a full multi-element transducer. Therefore, a realistic source model is built and implemented in a radiation code based on high-frequency asymptotic approximations where only L and T volume waves are calculated. The incapacity of this model to reproduce the behaviour of T waves in some directions of propagation has led to give a particular attention to the fore-waves, neglected in the radiation calculation. Chapter 3 treats of the building of an exact radiation model taking into consideration the fore-waves contribution emitted by a contact transducer exerting a random space-time distribution constraint at the surface of the considered medium. A radiation model, based on the calculation of exact Green functions of the Lamb problem is proposed. The exact model is particularly interesting in the case of sensor geometries with a long length with respect to other dimensions (2D case). Field calculation results are shown for an element of the matrix network (3D case) and for a linear element (2D case). A study of different existing approached models is carried out as well. The last chapter presents some results of the field

  15. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    Directory of Open Access Journals (Sweden)

    Vetrivel Chezian Sengodan

    2017-01-01

    Full Text Available Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001 at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  16. Trabecular microstructure and surface changes in the greater tuberosity in rotator cuff tears

    International Nuclear Information System (INIS)

    Jiang, Yebin; Zhao, Jenny; Ouyang, Xiaolong; Genant, Harry K.; Holsbeeck, Marnix T. van; Flynn, Michael J.

    2002-01-01

    Abstract Objective. When planning surgery in patients with rotator cuff tear, strength of bone at the tendon insertion and trabecular bone structure in the greater tuberosity are usually taken into consideration. We investigated radiographic changes in bone structure of the greater tuberosity in rotator cuff tears.Design. Twenty-two human cadaveric shoulders from subjects ranging from 55 to 75 years of age were obtained. The integrity of the rotator cuff was examined by sonography to determine if it is intact without any tear, or torn partially or completely. The humeral head was sectioned in 3 mm thick coronal slab sections and microradiographed. After digitization of the microradiographs and imaging processing with in-house semi-automated image processing software tools developed using software interfaces on a Sun workstation, the trabecular histomorphometrical structural parameters and connectivity in the greater tuberosity were quantified. The degenerative changes on the surface of the greater tuberosity were interpreted blindly by 2 independent readers.Results. Among the 22 shoulder specimens, the rotator cuff was found intact in 10 shoulders, partially in 7 and fully torn in 5. Statistically significant loss in apparent trabecular bone volume fraction, number of trabecular nodes, and number of trabecular branches, and a statistically significant increase in apparent trabecular separation and number of trabecular free ends were found in the greater tuberosity of the shoulders with tears. The loss was greater in association with full tear than in partial tear. Thickening of the cortical margin of the enthesis, irregularity of its surface, and calcification beyond the tidemark were observed in 2 (20%) shoulders with intact rotator cuff, in 6 (86%) shoulders with partial tear, and in 5 (100%) shoulders with full tear.Conclusions. Rotator cuff tears are associated with degenerative changes on the bone surface and with disuse osteopenia of the greater tuberosity

  17. Rotator cuff tendinopathy: is there a role for polyunsaturated Fatty acids and antioxidants?

    Science.gov (United States)

    Lewis, Jeremy S; Sandford, Fiona M

    2009-01-01

    Despite the lack of robust evidence, there has been a steady increase in the use of dietary supplements, including Omega 3 fatty acids and antioxidants, in the management of musculoskeletal conditions. One reason for this is that unsatisfactory outcomes with conventional treatments have lead sufferers to seek alternative solutions including the use of nutritional supplements. In the United Kingdom alone, the current supplement market is estimated to be over 300 pounds million per annum. One target market for nutritional supplements is tendinopathies including conditions involving the rotator cuff. This condition is debilitating and associated with considerable morbidity. Incidence increases with advancing age. High levels of cytokines, such as the pro-inflammatory interleukin 1 beta and vascular endothelial growth factor, have been reported within the bursa of patients with rotator cuff disease. There is also evidence that high concentrations of free-radical oxidants may also be involved in tendon pathology. Therefore, the possibility exists that dietary supplements may have a beneficial effect on tendon pathology, including that of the rotator cuff. A review was conducted to synthesize the available research literature on the histopathology of rotator cuff disease and the effectiveness of polyunsaturated fatty acids (PUFAs) and antioxidants on tendinopathies. A search was conducted using the MEDLINE, CINAHL, AMED, EMBASE, Cochrane, and PEDro databases using the terms "rotator cuff" and "tear/s" and "subacromial impingement syndrome," "burase," "bursitis," "tendinopathy," "tendinitis," "tendinosis," "polyunsaturated fatty acids," "PUFA," "Omega 3," "histopathology," "etiology," and "antioxidants." English language was an inclusion criterion. There were no randomized clinical trials found relating specifically to the rotator cuff. Only one trial was found that investigated the efficacy of PUFAs and antioxidants on tendinopathies. The findings suggest that some (low

  18. Interpretation of field potentials measured on a multi electrode array in pharmacological toxicity screening on primary and human pluripotent stem cell-derived cardiomyocytes

    NARCIS (Netherlands)

    Tertoolen, L.G.J.; Braam, S. R.; van Meer, B.J.; Passier, R.; Mummery, C. L.

    2018-01-01

    Multi electrode arrays (MEAs) are increasingly used to detect external field potentials in electrically active cells. Recently, in combination with cardiomyocytes derived from human (induced) pluripotent stem cells they have started to become a preferred tool to examine newly developed drugs for

  19. Evaluation of the Trends, Concomitant Procedures, and Complications With Open and Arthroscopic Rotator Cuff Repairs in the Medicare Population.

    Science.gov (United States)

    Jensen, Andrew R; Cha, Peter S; Devana, Sai K; Ishmael, Chad; Di Pauli von Treuheim, Theo; D'Oro, Anthony; Wang, Jeffrey C; McAllister, David R; Petrigliano, Frank A

    2017-10-01

    Medicare insures the largest population of patients at risk for rotator cuff tears in the United States. To evaluate the trends in incidence, concomitant procedures, and complications with open and arthroscopic rotator cuff repairs in Medicare patients. Cohort study; Level of evidence, 3. All Medicare patients who had undergone open or arthroscopic rotator cuff repair from 2005 through 2011 were identified with a claims database. Annual incidence, concomitant procedures, and postoperative complications were compared between these 2 groups. In total, 372,109 rotator cuff repairs were analyzed. The incidence of open repairs decreased (from 6.0 to 4.3 per 10,000 patients, P rotator cuff repairs have increased in incidence and now represent the majority of rotator cuff repair surgery. Among concomitant procedures, subacromial decompression was most commonly performed despite evidence suggesting a lack of efficacy. Infections and stiffness were rare complications that were slightly but significantly more frequent in open rotator cuff repairs.

  20. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    Science.gov (United States)

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high